Loading...
HomeMy WebLinkAbout20250121 NOI Architectural Plans 64 Greenwood AveJOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 12" = 1'-0" 64GR-HY-24 1.0 COVER SHEETNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision1SHEET LIST # SHEET NAME 1.0 COVER SHEET 1.1 GENERAL NOTES 1.2 EXISTING BASEMENT 1.3 PROPOSED BASEMENT 1.4 EXISTING 1ST FLOOR 1.5 PROPOSED DEMOLITION - 1ST FLOOR 1.6 PROPOSED 1ST FLOOR 1.7 POOL AREA - 1ST FLOOR 1.8 PROPOSED 2ND FLOOR 64 GREENWOOD AVE, HYANNIS - MASSACHUSSETS - 02601 SCHEMATIC DESIGN SET - DECEMBER 6th, 2024 PROJECT SCOPE:1.0 HOME RENOVATION SITE CONTEXT: 1- ALL WORK SHALL COMPLY WITH STATE AND LOCAL BUILDING CODES AND REGULATIONS 2- CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, AND PROCEDURES. 3- CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS DURING BUILDING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING AND BRACING TO ENSURE SUCH SAFETY. 4- ALL DIMENSIONS AND SITE CONDITIONS SHALL BE FIELD VERIFIED AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. NOTIFY THE OWNER OR DESIGNER OF ANY DISCREPANCY PRIOR TO COMMENCEMENT OF WORK. 5- IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, AND TO PROTECT THEM FROM DAMAGE. 6- ALL DETAILS, SECTIONS, NOTES, OR REFERENCE TO OTHER DRAWINGS ARE INTENDED TO BE TYPICAL. 7- DURING CONSTRUCTION, AND PRIOR TO THE INCORPORATION OF ANY CHANGES, REVISIONS, MODIFICATIONS OR DEVIATION FROM THE CONSTRUCTION DOCUMENT, CONTRACTOR SHALL BRING TO THE ATTENTION OF THE OWNER OR DESIGNER AND OBTAIN APPROVAL FROM THE BUILDING INSPECTOR BEFORE PROCEEDING WITH THE WORK. 8- SPECIFIC NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. 9- GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION. 10-CONTRACTOR SHALL PERFORM ALL WORKS IN COMPLIANCE: A- Building: INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 WITH ALL MA AMENDMENTS. Any reference in 780 CMR to the International Residential Code shall be considered reference to 780 CMR 51.00 through 120.00. B- Architectural Access:MASSACHUSETTS ARCHITECTURAL ACCESS BOARD 521-CMR AND THE AMERICANS WITH DISABILITIES ACT (ADAAG), WHERE REQUIRED. C- Mechanical:INTERNATIONAL MECHANICAL CODE (IMC) 2015 WITH 780 CMR - MA MECHANICAL AMENDMENTS. D- Electrical: 527 CMR 12.00 (2015 NATIONAL ELECTRICAL CODE) Any reference in 780 CMR to the International Electrical Code shall be considered reference to 527 CMR 12.00: Massachusetts Electrical Code (Amendments). E- Plumbing: 248 CMR MASSACHUSETTS PLUMBING REGULATIONS Reference to the International Plumbing Code shall be considered reference to 248 CMR: Board of State Examiners of Plumbers and Gas Fitters. F- Fire Prevention: INTERNATIONAL FIRE CODE (IFC) AND INTERNATIONAL MECHANICAL CODE (IMC) 2015 WITH 527 CMR REGULATIONS AND 780 CMR MA CODE AMENDMENTS G-Energy: 2018 IECC with MA AMENDMENTS." GENERAL NOTES: PROPOSED PROJECT: SHEET LIST # SHEET NAME 1.9 EXISTING ROOF AND PROPOSED DEMOLITION 1.10 PROPOSED ROOF PLAN 1.11 EXISTING AND PROPOSED FRONT ELEVATION 1.12 EXISTING AND PROPOSED LEFT ELEVATION 1.13 EXISTING AND PROPOSED RIGHT ELEVATION 1.14 EXISTING AND PROPOSED REAR ELEVATION 1.15 DOORS AND WINDOWS TAG 1.16 FIRE ALARM A.GENERAL NOTES 1. All work and materials shall conform with state and local codes and regulations, and shall be in accordance with good construction standards; 2. All dimensions to face of stud unless otherwise noted; 3. Verify all dimensions prior to ordering materials and/ or fabrication. Do not scale off drawings. Notify architect of any discrepancies in the plans prior to constructing areas in question. B.SITE WORKS 1. Excavation & Grading: Excavate for new foundation. Remove all excess soil. Grade surface to direct water away from house. Final finish grading, screened loam and seed, retaining walls, walkways, paving, gravel driveway, and finish landscaping shall be under separete contract. C.FLOOR CONSTRUCTION 1. Joists:As noted on framing plan. Galvanized joist and beam hangers for flush framing. Bridging or solid blocking rows between joists every 6 ft.(maximum). (Refer to Table R602,3(1)Fastener Schedule for Structural Members) Joists and hangers designed by others; 2. Decking: 3/4" T&G CDX plywood or "Advantek" decking glued and nailed to framing. Use 1/2" underlayment board under thin-set tile and VCT. Glue and nail underlayment to subfloor; 3. Insulate: Floors above unconditioned space to min R-30 using closed cell spray foam or per HERS RATER specifications; 4. Finish flooring: As per plan or Owner's selection. D.WALL CONSTRUCTION 1. Studs: No.2 2x6 KD spruce (SPF) studs @ 16" on center for all exterior wall construction. Interior partitions to be framed with 2x4 studs @ 16" on center, except where indicated, - Refer to Table R602,3(1) Fastener Schedule for Structural Members; 2. Top Plates: Cap walls with double top plate overlapped at corners and intersection with bearing partitions; 3. Sheathing: Install 1/2" exterior grade CDX plywood sheathing, nailed according to requirements of Table R602,3(2) Fastener Schedule for Structural Members. Apply building wrap ("Typar" or "Tyvek") on all exterior wall. Tape seams and apply double coverage at all corners. Alternatively, use "zip wall" sheathing and joint tape system; 4. Siding: Remove all existing siding on entire home. Prepare for new siding to replace existing. New siding per Owner's selection; 5. Trimboards, casing, and soffits: Per Owner's selection; 6. Thermal barrier: Insulate exterior walls with closed cell spray foam to min. R-30. Insulate interior walls around bathrooms, and all unheated spaces with fiberglass acoustical batts. Insulate all box headers and corner stud framing; 7. Finish: Install 1/2" Blueboard & plaster, prep, primed and painted with 2 finish coats (Colors selected by Owner). E. ROOF CONSTRUCTION: 1. Framing: See roof framing plans; 2. Ties: Install hurricane ties on each truss and rafter tall and each ridge seat with min. 365# uplift capacity (Simpson' 18 ga. H2.5 hurricane ties, or equal); 3. Sheathing: 5/8" exterior grade plywood sheathing nailed per Table R602,3(1) Fastener Schedule for Structural Members. Nail edges at 6" o.c. along gable ends. Alternatively use zip roof sheathing and joint tape system; 4. Roof Shingles: Install lifetime "Architectural" asphalt, 3 tab roof shingles over 30# felt paper. Verify manufacture's warranty-color to match existing roof; 5. Ice & Water Shield in valleys, over lower 3'-0" of roof edge over all slops with a pitch of less than 4 in 12 and minimum 12" up face of cheek wall; 6. Trim: Match existing. Verify with Owner; 7. Soffits and Porch ceiling: Composite trim boards, panels or beadboard per Owner's selection; 8. Insulation: Insulate roof to min R-60 using closed cell spray foam insulation or per HERS RATER specifications; 9. Finish: Install 1x3 strapping @ 16" on center and 4 mill poly vapor barrier. Install 1/2" Blueboard & veneer plaster. Prep and prime. Apply 2 finish coats. (Colors selected by Owner). F. DOORS AND WINDOWS: 1. Windows:(Refer to window schedule) Window and ext. doors shall be Energy Star rated and qualify for Federal Tax Credits. Install pre-finished aluminum cap flashing on windows and 6" wide "Vycor" membrane flashing around entire opening sealed to nailling flange and sheathing window openings. Install bituthane membrane pan flashing at sill; 2. Door sizes: Shall be as noted on plans and be approved by Owner; 3. Wind Pressure Rating: All exterior windows and doors to have min. 30 DP rating, which meet or exceed local wind pressure exposure ratings. Selected manufacturers shall provide product test documentation verifying compliance prior to ordering materials; 4. Exterior Doors: (see window schedule for exterior glass doors); 5. Interior Doors: Refer to plans for sizing. Owner to approve material, style, and finish. G. INTERIOR MILLWORK: 1. Trim: Install paint grade window and door casings, and baseboard to match existing; 2. Stairs: Hardwood railing and treads, and painted risers on all finished interior stairs. H. MECHANICAL, ELECTRICAL & FIRE PROTECTION: 1. HVAC & Plumbing: Review heating system options with owner. Provide all piping, ductwork and fittings as per code. Fixtures and faucets shall be approved by Owner; 2. Electrical: Review electrical options with Owner, install electrical, communication, outlets, switches, lighting, CAT 5 cable and TV jacks as directed by Owner; 3. Light Fixtures: Electrical contractor shall furnish all equipment and fixtures. Final locations of all fixtures to be approved by Owner; 4. Smoke, Heat and CO Detectors: Install hard wired smoke detectors, carbon monoxide and heat detectors as required by the local fire department. OUTLINE CONSTRUCTION SPECIFICATIONS: THE DRAWING REPRESENT CONSTRUCTION IN SCALE BUT DO NOT "SCALE" DRAWINGS TO OBTAIN MISSING INFORMATION OR TO INTERPRET ANY INFORMATION NOT SPECIFICALLY DIMENSIONED FOR EXACT DETAILING, FABRICATION OR CONSTRUCTION PURPOSES. CONTACT THE DESIGN ENGINEER FOR ANY REQUIRED MISSING DIMENSIONS. THE CONTRACTOR SHALL OBTAIN ALL PERMITS FROM THE BUILDING DEPARTMENT PRIOR TO THE START OF WORK. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK. VERIFY AND CONFIRM ALL DIMENSIONS, ELEVATIONS AND LOCATIONS OF EXISTING BUILDINGS AND OTHER STRUCTURES PRIOR COMMENCING THE WORK. DISCREPANCIES SHALL BE REPORTED TO THE DESIGN ENGINEER IMMEDIATELY, BEFORE PROCEEDING. THE CONTRACTOR ARE RESPONSIBLE FOR ACCURATE COORDINATION OF ALL RELATED PROJECT DRAWINGS, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, STRUCTURAL, CIVIL AND UTILITIES DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DETAILS, DIMENSIONS AND SYSTEMS PRIOR WORK OR ORDERING ANY ITEM AND COORDINATE WITH THE ARCHITECT OR THE RELATED ENGINEER. DO NOT COMMENCE WORK UNTIL CONDITION IS RESOLVED AND MODIFICATION IF NEEDED IS APPROVED. ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES THAT MAY EXIST PRIOR TO COMMENCING THE WORK. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING REQUIRED FOR PLUMPNESS, STRUCTURAL STABILITY AND SAFETY WHENEVER REQUIRED TO SUPPORT LOADS AS MAY BE IMPOSED UPON THE STRUCTURE AND ITS COMPONENTS DURING CONSTRUCTION. THE CONTRACTOR SHALL BE COMPLETELY RESPONSIBLE FOR THE SAFETY OF ADJACENT STRUCTURES, PROPERTY, HIS WORKMEN, AND THE PUBLIC, AS AFFECTED BY THE CONSTRUCTION OF THIS PROJECT. THESE DRAWINGS ARE INTENDED TO BE USED ONLY BY EXPERIENCED CONTRACTOR WITH KNOWLEDGE ON THIS TYPE OF WORK. SOULVE PLUS PERSONNEL ARE AVAILABLE TO ANSWER QUESTIONS AND ASSIST THE CONTRACTOR BY EXPLAINING THE DESIGN INTENT. CONTRACTOR SHALL UNDERSTAND THE COMPLEXITIES OF THE PROJECT AND THE CONSTRUCTION SEQUENCE . THE CONTRACTOR ASSUMES TOTAL RESPONSIBILITY FOR ANY CONSEQUENCE OF THAT ACTION. KEY NOTE: JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/4" = 1'-0" 64GR-HY-24 1.1 GENERAL NOTESNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision1 UP 615 SF EXISTING ROOM #4 299 SF EXISTING ROOM #1 67 SF EXISTING BATHROOM 310 SF EXISTING GARAGE 144 SF EXISTING ROOM #2 17 SF EX. CL #3 172 SF EXISTING EXTERNAL ROOM #1 142 SF EXISTING ROOM #3 JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 3/16" = 1'-0" 64GR-HY-24 1.2 EXISTING BASEMENTNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision13/16" = 1'-0"1 EXISTING BASEMENT UP 15' - 10 1/4"20' - 2" NEW CRAWL SPACE5' - 4"10' - 6 1/4"5' - 6 1/2" JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 3/16" = 1'-0" 64GR-HY-24 1.3 PROPOSED BASEMENTNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision13/16" = 1'-0"1 PROPOSED BASEMENT EXISTING GARAGEEXISTING ROOM #3 EXISTING ROOM #2 EXISTING ROOM #1 EXISTING BATHROOM EXISTING ROOM #4 EXISTING EXTERNAL ROOM #1 EX. CL. #3 EX. CL #2 EX. CL #1 DN EXISTING LIVING ROOM EXISTING KITCHEN EXISTING DINING EXISTING BEDROOM EXISTING BEDROOM EXISTING MASTER BEDROOM EXISTING M. BATHROOM EXISTING BATHROOM EXISTING FAMILY ROOM JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.4 EXISTING 1ST FLOORNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 EXISTING 1ST FLOOR DN EXISTING WALLS AND DOOR TO DEMOLISHEXISTING WINDOW TO DEMOLISH EXISTING WALL TO DEMOLISH EXISTING WALL TO DEMOLISH EXISTING RAILINGS TO DEMOLISH JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.5PROPOSED DEMOLITION -1STFLOORNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 PROPOSED DEMOLITION PLAN - 1ST FLOOR DN NEW EAT-IN ISLAND 5' - 2 1/2"4' - 1"5' - 7"10' - 2"3' - 9" NEW ENTRY DOOR NEW WINE AREA 14' - 11 1/4" NEW WINDOWS NEW DOOR NEW WINDOWS Z1 1 Z2 1 21' - 4 1/4"2' - 0"6' - 4 1/2"13' - 0 1/2"9' - 4"2' - 1"4' - 5"4' - 2"3' - 0" 20' - 5"16' - 6"UP 4' - 0"11' - 7"NEW DOOR PANEL 36" x 84" 337 SF KITCHEN 150 SF ENTRY 225 SF DINING 209 SF LIVING ROOM 141 SF COFFEE AREA 233 SF FAMILY ROOM 13 SF COAT CL. 146 SF EXTERIOR DECK 14' - 2 1/4" 155 SF BEDROOM 5' - 0"6' - 0"30 SF HALF BATH4' - 0"JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 3/16" = 1'-0" 64GR-HY-24 1.6 PROPOSED 1ST FLOORNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision13/16" = 1'-0"1 PROPOSED 1ST FLOOR PROPOSED ROOM SCHEDULE - 1ST FLOOR NAME AREA LEVEL KITCHEN 337 SF EXISTING 1ST FLOOR ENTRY 150 SF EXISTING 1ST FLOOR DINING 225 SF EXISTING 1ST FLOOR LIVING ROOM 209 SF EXISTING 1ST FLOOR COFFEE AREA 141 SF EXISTING 1ST FLOOR FAMILY ROOM 233 SF EXISTING 1ST FLOOR COAT CL. 13 SF EXISTING 1ST FLOOR BEDROOM 155 SF EXISTING 1ST FLOOR NEW EXTERIOR DECK1' - 3"21' - 0"1' - 3"11' - 6" JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/4" = 1'-0" 64GR-HY-24 1.7 POOL AREA -1ST FLOORNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/4" = 1'-0"1 PROPOSED 1ST FLOOR - Callout 3 19' - 10"14' - 7 1/4" DN 12' - 3"7' - 1 1/4"7' - 0" 91 SF M. BATHROOM 114 SF W.I.C. 284 SF M. BEDROOM 42 SF HALLWAY 136 SF LIVING 10' - 4 1/2"12' - 7 1/4"9' - 4"10' - 6"3' - 0"5' - 0"3' - 8 3/4" 6' - 6"12' - 3"16' - 4"7' - 0"10' - 11 1/2"OPEN TO BELOW 4' - 0"4' - 0"6' - 7 1/4" JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 3/16" = 1'-0" 64GR-HY-24 1.8 PROPOSED 2ND FLOORNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision13/16" = 1'-0"1 PROPOSED 2ND FLOOR PROPOSED ROOM SCHEDULE - 2ND FLOOR NAME AREA LEVEL LIVING 136 SF PROPOSED 2ND FLOOR M. BATHROOM 91 SF PROPOSED 2ND FLOOR W.I.C. 114 SF PROPOSED 2ND FLOOR M. BEDROOM 284 SF PROPOSED 2ND FLOOR HALLWAY 42 SF PROPOSED 2ND FLOOR EXISTING ROOF DEMOLITION ROOF JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.9EXISTING ROOF AND PROPOSEDDEMOLITIONNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 EXISTING ROOF 1/8" = 1'-0"2 PROPOSED DEMOLITION PLAN - ROOF EXISTING ROOF TO REMAIN 1'-0" / 1'-0"1'-0" / 1'-0"9 3/4" / 1'-0"7 1/2" / 1'-0"7 1/2" / 1'-0"8" / 1'-0"8" / 1'-0"9 3/4" / 1'-0"9 3/4" / 1'-0" 9 3/4" / 1'-0"9 3/4" / 1'-0" 3" / 1'-0"8" / 1'-0"8" / 1'-0"JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 3/16" = 1'-0" 64GR-HY-24 1.10PROPOSED ROOF PLANNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision13/16" = 1'-0"1 PROPOSED ROOF EXISTING 1ST FLOOR 0' -0" EXISTING ATTIC 8' -1 1/2" EXISTING 1ST FLOOR 0' -0" EXISTING ATTIC 8' -1 1/2" EXISTING LEVEL 30 17' -4"5' - 9 1/2"9' - 2 1/2"8' - 1 1/2"23' - 1 1/2"JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.11EXISTING AND PROPOSEDFRONT ELEVATIONNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 EXISTING FRONT ELEVATION 1/8" = 1'-0"2 PROPOSED FRONT ELEVATION EXISTING 1ST FLOOR 0' -0" EXISTING ATTIC 8' -1 1/2" EXISTING 1ST FLOOR 0' -0" EXISTING ATTIC 8' -1 1/2" EXISTING LEVEL 30 17' -4"8' - 1 1/2"9' - 2 1/2"5' - 9 1/2"23' - 1 1/2"JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.12EXISTING AND PROPOSED LEFTELEVATIONNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 EXISTING LEFT ELEVATION 1/8" = 1'-0"2 PROPOSED LEFT ELEVATION EXISTING 1ST FLOOR 0' -0" EXISTING BASEMENT -8' -4" EXISTING ATTIC 8' -1 1/2" EXISTING 1ST FLOOR 0' -0" EXISTING BASEMENT -8' -4" EXISTING ATTIC 8' -1 1/2" EXISTING LEVEL 30 17' -4"8' - 4"8' - 1 1/2"9' - 2 1/2"5' - 1"22' - 5"JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.13EXISTING AND PROPOSEDRIGHT ELEVATIONNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 EXISTING RIGHT ELEVATION 1/8" = 1'-0"2 PROPOSED RIGHT ELEVATION EXISTING 1ST FLOOR 0' -0" EXISTING BASEMENT -8' -4" EXISTING ATTIC 8' -1 1/2" EXISTING 1ST FLOOR 0' -0" EXISTING BASEMENT -8' -4" EXISTING ATTIC 8' -1 1/2" EXISTING LEVEL 30 17' -4"8' - 4"8' - 1 1/2"9' - 2 1/2"5' - 9 1/2"23' - 1 1/2"JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1/8" = 1'-0" 64GR-HY-24 1.14EXISTING AND PROPOSED REARELEVATIONNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/8" = 1'-0"1 EXISTING REAR ELEVATION 1/8" = 1'-0"2 PROPOSED REAR ELEVATION DN A1A21-1 1-3 A3A4A5 A6 1-2 A7 A8 1-4 A9 1-5 B1B2 2-5 2-4 2-3 2-2 B20 B19B18 B3 B4 B5 B6 B7 B8 B9 B10 B11 2-6 2-7 B12 B13 B14 B15 B16 B17 2-1 JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION 1" = 10'-0" 64GR-HY-24 1.15DOORS AND WINDOWS TAGNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11" = 10'-0"1 DOORS AND WINDOWS - PROPOSED 1ST FLOOR 1" = 10'-0"2 DOORS AND WINDOWS - PROPOSED 2ND FLOOR PROPOSED DOOR SCHEDULE MARK WIDTH HEIGHT LEVEL 1-1 3' - 0" 6' - 8" EXISTING 1ST FLOOR 1-2 17' - 0" 6' - 8" EXISTING 1ST FLOOR 1-3 5' - 0" 6' - 8" EXISTING 1ST FLOOR 1-4 12' - 0" 7' - 0" EXISTING 1ST FLOOR 1-5 2' - 6" 6' - 8" EXISTING 1ST FLOOR 2-1 2' - 8" 6' - 8" EXISTING ATTIC 2-2 2' - 8" 6' - 8" EXISTING ATTIC 2-3 2' - 8" 6' - 8" EXISTING ATTIC 2-4 2' - 6" 6' - 8" EXISTING ATTIC 2-5 4' - 0" 6' - 8" EXISTING ATTIC 2-6 6' - 0" 6' - 8" EXISTING ATTIC 2-7 6' - 0" 6' - 8" EXISTING ATTIC PROPOSED WINDOW SCHEDULE MARK WIDTH HEIGHT SILL HEIGHT LEVEL A1 2' - 6" 3' - 10" 2' - 10" EXISTING 1ST FLOOR A2 2' - 6" 3' - 10" 2' - 10" EXISTING 1ST FLOOR A3 2' - 6" 3' - 10" 3' - 0" EXISTING 1ST FLOOR A4 2' - 6" 3' - 10" 3' - 0" EXISTING 1ST FLOOR A5 2' - 6" 3' - 10" 3' - 0" EXISTING 1ST FLOOR A6 2' - 6" 3' - 10" 3' - 0" EXISTING 1ST FLOOR A7 2' - 6" 3' - 6" 3' - 0 1/2" EXISTING 1ST FLOOR A8 2' - 6" 3' - 6" 3' - 0 1/2" EXISTING 1ST FLOOR A9 2' - 6" 3' - 10" 3' - 0" EXISTING 1ST FLOOR B1 4' - 0" 3' - 0" 3' - 8" PROPOSED 2ND FLOOR B2 4' - 0" 3' - 0" 5' - 2" EXISTING ATTIC B3 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B4 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B5 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC PROPOSED WINDOW SCHEDULE MARK WIDTH HEIGHT SILL HEIGHT LEVEL B6 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B7 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B8 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B9 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B10 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B11 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B12 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B13 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B14 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B15 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B16 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B17 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B18 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B19 2' - 6" 3' - 10" 2' - 10" EXISTING ATTIC B20 8' - 0" 3' - 2" 4' - 4" EXISTING ATTIC DN SC ALL SMOKE AND CARBON-MONOXIDE DETECTORS MUST BE HARD-WIREDCARBON MONOXIDE DETECTORS [R315 PG. 68 AMENDED] • 1 IN EACH HABITAL STORY OF THE HOUSE AND WITHIN 10 FT. OF ALL BEDROOMS. COMBINATION PHOTOELECTRIC SENSITIVE SMOKE/CARBON MONOXIDE DETECTORS [R315.4 PG. 68 AMENDED] • MAY BE USED WHERE SMOKE DETECTORS ARE LOCATED PER R315,3 HEAT DETECTORS • 1 IN EACH ATTACHED GARAGE, NEAR CENTER. PHOTOELECTRIC SENSITIVE SMOKE DETECTORS [R314 PG. 67 AMENDED] • 1 IN EACH SEPARATE BEDROOM • 1 OUTSIDE EACH SEPARATE BEDROOM • 1 NEAR BASE OF EACH STAIRWAY • 1 IN EVERY BASEMENT & WALK UP ATTIC • 1 FOR EVERY 1,000 SQ. FT. SC C S H LIFE SAFETY FIXTURES LEGEND BATH / LIGHT COMBO EXHAUST FAN SC S S S SC EGRESS WINDOW EGRESS WINDOW EGRESS WINDOW SC SC S SC EGRESS WINDOW JOHN KARAVOLAS CIVIL No. 38495COMMONWEALTHOFMASSACHUSETTS PROFESSIONALENGIN EER Scale Project (978) 759-7799 contact@soulveplus.com www.soulveplus.com #Date:Drawn by:DESCRIPTION As indicated 64GR-HY-24 1.16FIRE ALARMNEW CONSTRUCTION64 GREENWOOD AVE, HYANNIS -MA12/06/2024revision11/16" = 1'-0"1 PROPOSED BASEMENT - FIRE ALARM 1/16" = 1'-0"2 PROPOSED 1ST FLOOR - FIRE ALARM 1/16" = 1'-0"3 PROPOSED 2ND FLOOR - FIRE ALARM