HomeMy WebLinkAboutBarnstable Straightway NOI_12.23.2024_Plans 1 ATTACHMENT B Project Plans ____________________________________________________________________________ CAD FILE: L:\Town Of Barnstable MA\24003062.001A-W-Barnstable MA - New Stra\Working\04 - Design Phase\06 - CAD\Production Drawings\0-COVER.dwg LAYOUT: 0-COVERPLOTTED: 12/23/2024 3:46 PM BY: matthew stevensTOWN OF BARNSTABLE, MASSACHUSETTS TOWN OF BARNSTABLE DEPARTMENT OF PUBLIC WORKS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 STRAIGHTWAY WATER TREATMENT FACILITY PROJECT MILESTONES / REVISIONS DATE TYPE DESCRIPTION 6/10/2024 30% DESIGN SUBMITTAL 9/20/2024 60% DESIGN SUBMITTAL 11/15/2024 SITE PLAN REVIEW 12/23/2024 NOI SUBMITTAL DECEMBER 2024 SCALE: 1" = 1000' LOCUS PLAN STRAIGHTWAY SITE HYANNISPORT AND SIMMONS POND SITE N DWSRF-16849 CONTRACT NO. XX-XX-XX NOT FOR CONSTRUCTION TOWN MANAGER MARK ELLS DPW DIRECTOR DAN SANTOS, P.E. TOWN ENGINEER GRIFFIN BEAUDOIN, P.E. WATER SUPPLY DIVISION SUPERVISOR HANS KEIJSER PROJECT MANAGER MATTHEW WROBEL, P.E. 12/23/2024 ######## G0-001 2 SHEET INDEX TB MD TB MT NOT FOR CONSTRUCTION One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY 12/23/2024 GENERAL NOTES WORK OF GENERAL CONTRACTOR: 1.THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS REQUIRED TO COMPLETE THE STRAIGHTWAY WATER TREATMENT FACILITY PROJECT, COMPLETE AND READY FOR OPERATION AS INDICATED ON THE DRAWINGS AND SPECIFICATIONS, INCLUDING ALL CONTRACT DOCUMENTS. 2.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF SUBCONTRACTORS' WORK WITH EACH OTHER AND WITH THE WORK OF THE GENERAL CONTRACTOR. 3.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE OVERALL CONSTRUCTION SEQUENCE. 4.THE GENERAL CONTRACTOR SHALL NOT STORE EQUIPMENT OR STOCKPILE MATERIAL WITHIN WETLAND BUFFER ZONES. STORING EQUIPMENT OR STOCKPILING MATERIAL ON TOWN OWNED LAND WILL REQUIRE TOWN AUTHORIZATION. 5.SOME PIPE/EQUIPMENT CONNECTIONS MAY REQUIRE TRANSITION FITTING OR OTHER FITTINGS NOT SHOWN ON DRAWINGS, THE CONTRACTOR SHALL PROVIDE ADEQUATE FITTING TO MAKE COMPLETE CONNECTION. 6.WHERE BURIED DUCTILE IRON PIPE LEAVES/ENTERS A BUILDING OR STRUCTURE, THE GENERAL CONTRACTOR SHALL PROVIDE MULTIPLE MECHANICAL JOINT BELLS. 7.PROPOSED FIELD MODIFICATION, REVISIONS AND ADDITIONS TO THE DESIGN DRAWINGS MUST BE APPROVED BY THE ENGINEER, IN WRITING, BEFORE WORK BEGINS. ANY REQUEST TO DEVIATE FROM THE ENGINEER'S SPECIFIED DETAILS ON THE DESIGN DRAWINGS BY THE CONTRACTOR MUST BE SUBMITTED IN WRITING TO THE ENGINEER FOR APPROVAL. CONTRACTOR WILL NOT BE PAID FOR ANY WORK PERFORMED WITHOUT PRIOR APPROVAL AND MAY BE REQUIRED TO REMOVE AT THEIR OWN EXPENSE WITHOUT IMPACT TO THE PROJECT SCHEDULE. 8.GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL VISIT THE PROJECT SITE AND OBSERVE CONDITIONS FOR THE PROPOSED CONSTRUCTION. ANY DISCREPANCY BETWEEN THE DESIGN DRAWINGS AND ACTUAL SITE CONDITIONS MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER, IN WRITING, FOR RESOLUTION PRIOR TO COMMENCEMENT OF THE WORK. 9.THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, ELEVATIONS AND DIMENSIONS PRIOR TO FABRICATING NEW WORK THAT WILL BE CONNECTED TO EXISTING CONSTRUCTION. 10.ALL ITEMS OF CONSTRUCTION MUST BE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT INCLUDING THE BUILD AMERICA, BUY AMERICA ACT (BABA) AND THE AMERICAN IRON AND STEEL (AIS) REQUIREMENT. 11.THE CONTRACTOR IS RESPONSIBLE FOR SEGREGATING WORK AREAS FROM THE GENERAL PUBLIC USING TEMPORARY FENCES, SIGNS, CONES, CAUTION TAPE, ETC. 12.THE CONTRACTOR'S BID FOR THIS PROJECT MUST INCLUDE ALL LABOR, MOBILIZATION, PERMITTING, MATERIALS, TEMPORARY PROTECTION, ETC. NO ADDITIONAL COSTS WILL BE SUBMITTED TO THE ENGINEER IN ORDER TO COMPLETE THE INTENT OF THE WORK AS INDICATED ON THE DESIGN DRAWINGS. 13.IN LOCATIONS WHERE WATER IS IN SUFFICIENT SUPPLY, THE CONTRACTOR MAY BE ALLOWED TO USE WATER WITHOUT CHARGE FOR CONSTRUCTION PURPOSES AFTER APPROVAL OF THE OWNER IS OBTAINED. ELECTRICITY SHALL STILL BE PROVIDED BY THE CONTRACTOR. IN LOCATIONS WHERE WATER IS NOT IN SUFFICIENT SUPPLY, THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING WATER AND ELECTRICITY REQUIRED TO PERFORM THE WORK. SUBMIT PROPOSED MEANS AND METHODS TO THE ENGINEER FOR REVIEW. 14.ALL DIMENSIONS AND QUANTITIES MUST BE DETERMINED OR VERIFIED BY THE CONTRACTOR. QUANTITIES TO BE CARRIED UNDER THE BASE BID WORK HAVE BEEN INDICATED ON THE CONTRACT DRAWINGS. THE CONTRACT DRAWINGS HAVE BEEN COMPILED FROM VARIOUS SOURCES AND MAY NOT REFLECT THE ACTUAL CONDITION AT THE MOMENT OF CONSTRUCTION. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS AND MAKE ALL INVESTIGATIONS NECESSARY TO INSTALL THE PROPOSED WORK. 15.IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS TO REVIEW ALL DRAWINGS, PROJECT MANUAL, PROJECT SPECIFICATIONS, SCHEDULES, ADDENDA ETC. IN ORDER TO ASSURE THE COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO REVIEW AND COORDINATE ALL CONTRACTOR DOCUMENTS BY THE GENERAL WITH ALL THE SUBCONTRACTORS FOR APPLICABLE ITEMS OF THE WORK SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING ALL WORK SO REQUIRED AS PART OF THE CONTRACT. 16.IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS FOLLOWING THE REVIEW OF ALL THE DRAWINGS, PROJECT MANUAL, ADDENDA, ETC. TO INFORM THE ENGINEER OF ANY DISCREPANCIES IN THE DOCUMENTS AND TO OBTAIN CLARIFICATION ON ALL ITEMS AFFECTING CONSTRUCTION COST PRIOR TO THE SUBMISSION OF THE BID. 17.THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE DPW OF ANY TRAFFIC DETAIL OR FLAGGER REQUESTS AND OF CANCELLATION IN THE EVENT THEY ARE NO LONGER NEEDED. ANY COST INCURRED BY THE DPW FOR POLICE DETAILS CANCELED WITH INSUFFICIENT NOTICE BY THE CONTRACTOR WILL BE REIMBURSED TO THE DPW BY THE CONTRACTOR. 18.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH THE HYANNIS WATER SYSTEM (VEOLIA/DPW) FOR ANY WATER SHUTDOWNS OR CONNECTIONS INCLUDING THOSE REQUIRED FOR CHLORINATION AND PRESSURE TESTING. 19.THE CONTRACTOR WILL BE ASSESSED DAILY LIQUIDATED DAMAGES FOR ANY WORK BEYOND THE CONTRACT DEADLINE IF NOT APPROVED FOR EXTENSION. 20.THE CONTRACTOR AND ALL PRODUCTS INCORPORATED INTO THE WORK MUST COMPLY WITH ALL BABA, DWSRF, AND AIS REQUIREMENTS. 21.WORK HOURS WILL BE CLARIFIED WITH THE DPW AND REQUESTS OUTSIDE OF THESE HOURS REQUIRE WRITTEN NOTICE/APPROVAL BY DPW DIRECTOR. 22.TREE CLEARING SHALL NOT OCCUR BETWEEN MARCH 15 AND OCTOBER 1. 23.FOLLOWING FINAL CONNECTIONS AND RECEIPT OF MASSDEP APPROVAL TO OPERATE THE NEW SIMMONS POND AND HYANNISPORT PUMP STATIONS, THE EXISTING PUMP STATIONS SHALL BE DEMOLISHED AND ALL MATERIALS SHALL BE REMOVED AND DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. A PRE-DEMOLITION SURVEY FOR EACH BUILDING IS INCLUDED IN APPENDIX XXXXX OF THE SPECIFICATIONS. GENERAL NOTES: 1.PRIOR TO BIDDING THE PROJECT, THE CONTRACTOR IS ENCOURAGED VISIT THE SITE TO VERIFY EXISTING CONDITIONS. 2.THE DATA ACCUMULATION AND BOUNDARY SURVEY DEPICTED HERE WERE OBTAINED BY A FIELD SURVEY BETWEEN NOVEMBER 28 AND DECEMBER 6, 2023 BY CHESS ENGINEERING, LLC. THIS PLAN AND SURVEY WERE PREPARED USING CONVENTIONAL & RTK SURVEY METHODS. A LEICA MS60 TOTAL STATION WAS USED HAVING A MINIMAL AT ACCURACY OF 1" AND 1 PPM. A LEICA GS-18 GNSS RECEIVER WAS UTILIZED THROUGHOUT THE PROJECT AREA FOR REDUNDANT MEASUREMENTS BETWEEN NOVEMBER 27-30, 2023 AND ADDITIONALLY BETWEEN FEBRUARY 26-27, 2024 TO CONFIRM PREVIOUS MEASUREMENTS. BASE MAP INFORMATION WAS PREPARED BY CHESS ENGINEERING, LLC DATED MAY 23, 2024. THE COORDINATES OF THE SURVEY ARE IN FEET AND ARE BASED UPON THE NORTH AMERICAN DATUM OF 1983 MASSACHUSETTS STATE PLANE (NAD '83 MASSACHUSETTS STATE PLANE, MAINLAND ZONE). THE ELEVATIONS OF THE SURVEYS ARE IN FEET AND REFER TO NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD '88). 3.FOR TEMPORARY BENCH MARKS: SEE SHEET C1-111: TBM: WESTERLY HYDRANT FLANGE BOLT. ELEV. = 24.36' TBM: TOP OF CONCRETE BASE. ELEV. = 31.77' TBM: TOP OF CONCRETE PAD. ELEV. = 32.49' TBM: CONCRETE BOUND 1. ELEV. = 23.12' TBM: CONCRETE BOUND 2. ELEV. = 21.03' TBM: CONCRETE BOUND 3. ELEV. = 28.68' SEE SHEET C2-111: TBM: SOUTH-EASTERLY HYDRANT FLANGE BOLT. ELEV. = 17.77' TBM: SOUTH-EASTERLY HYDRANT FLANGE BOLT. ELEV. = 13.61' TBM: CONCRETE BOUND 4. ELEV. = 15.17' TBM: CONCRETE BOUND 5. ELEV. = 17.12' 4.THE WETLANDS WERE DELINEATED ON NOVEMBER 29, 2023 BY LUCAS ENVIRONMENTAL. 5.THE CONTRACTOR SHALL CALL THE DIG-SAFE CENTER AT 1-888-344-7233 A MINIMUM OF 72 HOURS PRIOR TO ANY EXCAVATION TO LOCATE UNDERGROUND UTILITIES IN THE FIELD AND NOTIFY UTILITIES OF CONSTRUCTION. 6.INFORMATION SHOWN ON THE DRAWINGS RELATING TO MATERIALS, CONDITIONS AND/OR LOCATIONS OF EXISTING STRUCTURES AND UTILITIES HAS BEEN COMPILED FROM AVAILABLE INFORMATION INCLUDING FIELD SURVEY, AERIAL PHOTOGRAPHY, RECORD MAPS AND DRAWINGS, AND UTILITY RECORD DRAWINGS AND IS NOT GUARANTEED CORRECT OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY EXISTING CONDITIONS AND DIMENSIONS INCLUDING THE LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. LOCATIONS AND DEPTHS OF CRITICAL UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD BY TEST PITS AS APPROVED BY THE ENGINEER. ANY DAMAGE TO UTILITIES OR PUBLIC/PRIVATE PROPERTY CAUSED BY THE CONTRACTOR SHALL BE THE CONTRACTOR'S RESPONSIBILITY, AND COSTS FOR THE REPAIR OR REPLACEMENT OF SUCH DAMAGED UTILITIES OR PROPERTY SHALL BE BORNE BY THE CONTRACTOR. 7.ACCORDING TO FEMA FIRM (FLOOD INSURANCE RATE MAP) COMMUNITY PANEL 250001; REVISION DATED 7/16/2014, THE APPROXIMATE 100-YEAR FLOODPLAIN ELEVATION ON THE SITE IS 12 FEET. THIS FIRM APPLIES TO BOTH SITES SHOWN IN THIS PLANSET. NO WORK IS PROPOSED WITHIN THE 100-YEAR FLOODPLAIN. 8.THE EXISTING WATER TREATMENT FACILITY, SIMMONS POND WELLS, AND HYANNISPORT WELLS MUST BE LEFT OPERATIONAL AT ALL TIMES DURING CONSTRUCTION OF NEW STRAIGHTWAY FACILITIES EXCLUDING APPROVED CONNECTION SHUTDOWNS. ALL SHUTDOWNS WILL REQUIRE ADVANCE COORDINATION WITH ENGINEER, VEOLIA, AND HYANNIS WATER SYSTEM. SHUTDOWNS WILL NOT BE PERMITTED BETWEEN MAY 1 AND SEPTEMBER 1. 9.HYANNIS WATER SYSTEM TO REQUIRE A THIRD PARTY INSPECTOR ONSITE DURING ALL PHASES OF CONSTRUCTION. G0-002 3 - TB MD TB MT SOIL EROSION AND SEDIMENT CONTROL NOTES: 1.APPROPRIATE EROSION AND SEDIMENT CONTROL MEASURES TO COMPLY WITH THE REQUIREMENTS OF THE STORM WATER MANAGEMENT PERMIT SHALL BE INSTALLED PRIOR TO SOIL DISTURBANCE. MEASURES SHALL BE TAKEN TO CONTROL EROSION WITHIN THE PROJECT AREA. SEDIMENT IN RUNOFF WATER SHALL BE TRAPPED AND RETAINED WITHIN THE PROJECT AREA. WETLAND AREAS AND SURFACE WATERS SHALL BE PROTECTED FROM SEDIMENT. 2.CONTRACTOR SHALL MINIMIZE TOTAL AREA OF DISTURBANCE AND PROTECT NATURAL FEATURES AND SOIL. 3.INSTALL AND MAINTAIN ALL EROSION AND SEDIMENT CONTROL MEASURES IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS AND/OR IN ACCORDANCE WITH ALL PERMIT REQUIREMENTS, THE MORE STRINGENT REQUIREMENT SHALL APPLY. CONTRACTOR SHALL INSTALL EROSION AND SEDIMENTATION CONTROLS IN ACCORDANCE WITH SPECIFICATION SECTION 01568 AND DETAILS PROVIDED ON SHEET C1-111 THROUGH C5-056. 4.CONTRACTOR TO COMPLY WITH APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS INCLUDING WASTE DISPOSAL. 5.CONTRACTOR SHALL PROPERLY MANAGE ON-SITE CONSTRUCTION AND WASTE MATERIALS. 6.CONTRACTOR SHALL IMPLEMENT APPROPRIATE DUST CONTROL MEASURES AT THE SITE. 7.STOCKPILE SIDE SLOPES SHALL NOT BE GREATER THAN 1:1. ALL STOCKPILES SHALL BE SURROUNDED BY SEDIMENT CONTROLS. 8.A VEHICLE TRACKING PAD OR OTHER APPROVED STABILIZATION METHOD SHALL BE CONSTRUCTED AT ALL ENTRANCE/EXIT POINTS OF THE SITE TO PREVENT SOIL CARRIED ONTO ROADWAYS AND OFF THE SITE. CONTRACTOR SHALL FURNISH A MECHANICAL SWEEPER ON SITE FOR THE PURPOSE OF SWEEPING ALL PAVED AREAS ON A DAILY BASIS OR AS REQUIRED TO PREVENT SOIL TRACKING ON ROADWAYS. 9.ALL PREVIOUSLY DISTURBED LAND SHALL BE STABILIZED BY APPROVED METHODS WITHIN 14 DAYS IF LEFT UNDISTURBED. THIS INCLUDES STOCKPILES, CONSTRUCTION ENTRANCES, GRADED AREAS AND OTHER CONSTRUCTION ACTIVITY RELATED CLEARING 10.PERMANENT SEEDING SHALL BE UNDERTAKEN IN THE SPRING FROM APRIL 15 THROUGH JUNE 1, AND IN LATE SUMMER AND EARLY FALL FROM AUGUST 15 THROUGH NOVEMBER 1. DURING THE PEAK SUMMER MONTHS AND IN THE FALL AFTER NOVEMBER 1, WHEN SEEDING IS FOUND TO BE IMPRACTICAL, APPROPRIATE TEMPORARY STABILIZATION SHALL BE APPLIED. PERMANENT SEEDING MAY BE UNDERTAKEN DURING THE SUMMER IF PLANS PROVIDE FOR ADEQUATE MULCHING AND WATERING. IN ACCORDANCE WITH SPECIFICATION SECTION 02480, THE PLANTING AREA WILL BECOME ACCEPTABLE IF THE GRASS AND SEED MIXTURES SHOW A UNIFORM, THICK, AND WELL-DEVELOPED GROWTH. IF AN INSUFFICIENT PERCENTAGE OF GRASS ESTABLISHES, THE CONTRACTOR WILL NEED TO RESEED AT THEIR OWN EXPENSE. NATIVE SEED MIXES SHALL CONFORM TO MASSDOT STANDARD NATIVE UPLAND SEED MIXES. 11.IF WORK IS HALTED OVER WINTER MONTHS THE CONTRACTOR SHALL BE RESPONSIBLE FOR STABILIZING THE AREA THROUGH GROUNDCOVER PRACTICES. NOT FOR CONSTRUCTION COUPLING BACKWASH WASTE EXISTING LEGEND CHAIN LINK FENCE DUCTILE IRON MINOR CONTOUR129 MAJOR CONTOUR130 SPOT ELEVATION129.9 RECORD WATER LINE HYDRANT WATER GATE WATER WELL STANDPIPE ELECTRIC LINE UTILITY POLE TRANSFORMER GUY WIRE RECORD GAS LINES GAS METER WETLAND LIMIT WETLAND FLAG 100' WETLAND BUFFER100' WB OVERHEAD WIRES CHAINLINK FENCE SOIL PROBE TREELINE CONCRETE PAD EDGE OF PAVEMENT ABANDONED/REMOVED WATER LINE ELECTRIC MANHOLE PROPOSED LEGEND SEWER LINE DRAIN LINE DRAIN LINE DRAIN MANHOLE SEWER LINE SEWER MANHOLE D S WATER LINE PROPOSED WATER GATE VEHICULAR ACCESS GATE EXTENT OF STORMWATER FEATURE PROPOSED BUILDING PROPOSED TREELINE CHAIN LINK FENCE WETLAND EDGE EDGE OF PAVEMENT LINE 100-YR FLOOD ZONE EXTENT OF PAVED ACCESS DRIVE 50' WETLAND BUFFER50' WB EXTENT OF ASPHALT/STRUCTURE REMOVAL EDGE OF WATER RAW WATER LINERW AREA OF STORMWATER FEATURE CONCRETE EXTENT OF ASPHALT/STRUCTURE REMOVAL GAS LINE ELECTRIC LINE ARBORVITAE PLANTING DRAIN MANHOLE CATCH BASIN PROPOSED CONTOUR19 RIPRAP STRAW WATTLE SP CLF CP DI EOP GM E SP SPOT GRADE129.9 200' RIVERFRONT AREA200' RFA 100' RIVERFRONT AREA100' RFA PROPOSED WATER TAP One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY B-X SOIL BORING 12/23/2024 12/23/2024 12/23/2024 20.0'16.0 'EDGE OF S IMMONSPOND (G IS LOCAT ION) BENS POND SIMMONS PONDHOMEPORT DRIVESECURITY STREETOLD S C H O OL H O U S E R O A D HYANNISPORT COURTSMITH STREET C R A I G V I L L E B E A C H R O A DSTRAIGHTWAYSTRAIGHTWAY HOM E P O R T D RI V E PROP. WINTERIZED GAC BUILDING PROP. STRAIGHTWAY WATER TREATMENT FACILITY PROP. SIMMONS POND REPLACEMENT WELL AND PUMP STATION BUILDING PROP. HYANNISPORT REPLACEMENT WELL AND PUMP STATION BUILDING STRAIGHTWAY SITE PLAN HYANNISPORT AND SIMMONS POND SITE PLAN EXIST. SIMMONS POND PUMP STATION BUILDING EXIST. HYANNISPORT PUMP STATION BUILDING EXIST. CHLORINATION FACILITY EXIST. WATER STORAGE TANK EXIST. BOOSTER PUMP STATION EXIST. STRAIGHTWAY WELL FACILITY PROP. STORMWATER TREATMENT BASIN (TYP.) ACCESS DRIVE BETWEEN TWO SITES PROP. PAVED DRIVEWAY EXIST. PAVED DRIVEWAY EXIST. GRAVEL DRIVEWAY PROP. PAVED DRIVEWAY AND TURNAROUND PROP. PAVED DRIVEWAY TURNOUT/PARKING AREA EXIST. GRAVEL PARKING AREA STRAIGHTWAY WELL 1 (PWSID 4020004-01G) AND STRAIGHTWAY WELL 2 (PWSID 4020004-12G) SIMMONS POND WELL (PWSID 4020004-06G) HYANNISPORT WELL (PWSID 4020004-03G) EXIST. PAVED DRIVEWAY SITE ENTRANCE/ACCESS GATE SITE ENTRANCE/ACCESS GATE HALLS CREEK ######## C0-001 4 STRAIGHTWAY WATER TREATMENT FACILITY GENERAL KEY PLAN SCALE IN FEET 0 150 300 450 SCALE: 1" = 150' NOT FOR CONSTRUCTION N MPS MD/MPS TB/GAA GAA - One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY 12/23/2024 12/23/2024 12/23/2024 303028292931312827252223242621201 9 1716163 0 30 28 29 25 22 2324 26 27 21 20 24 23 1 9 20 21 22 23 20 19 18 18 20 2531 2 930282 7 2 6 3332 3131313131 32 2 0 20201 9 19 2121 21222 3 26 252423 27 3 2313029 28 27 26 25 24 23 22 21 30 29 WF C-107WF C - 1 0 8 WF C-109 WF C-110 WF C-111 WF C - 1 1 3 WF C-1START WF C-3 WF C-2 WF C-4 WF C--5 WF C-6 WF C-7 WF C-8 WF C-9 WF C-102 WF C-103 WF C-104 WF C-105 WF C-106 EXISTING WATER STORAGE TANKGRAV E L D R IV EWA Y EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATIONWF C-115 WF C-116 WF C-117 WF C-118 UP# 43.9'38.6'27.5'TRANSFORMER RIP-RAP (TYP) UNDERGROUND ELECTRIC LOCATION APPROXIMATE EMH NO ACCESS EXISTING GAS LINE LOCATION APPROXIMATE DMHs - 8' LEACH PIT RIM = 22.5' INTERCONNECT = ± 19.2' BOTTOM STONE= ± 14.9' DMH - 8' LEACH PIT RIM = 22.6' INV (IN)= ± 19.5' INTERCONNECT= ± 19.6' BOTTOM STONE= ± 14.9' 12" CORRUGATED HDPECHAINLINK FENCE (TYP)CHAI N L I N K F E N C E ( T Y P ) CHAINLINK FENCE (TYP) UP#3 EMH (2) 2.5" PVC CONDUITS IN/OUT FFE = ± 23.2'FFE = ± 23.9' FFE = ± 32.7' 6" GATE VALVE TREELINE (TYP)TREELINE (TYP)TREELINE (TYP) EMH NO ACCESS EMH (6) 2.5" PVC CONDUITS IN/OUT UNDE R G R O U N D E L E C T R I C L O C A T I O N A P P R O X I M A T E FRO M R E C O R D P L A N S CONCRETE BOUND FOUND-HELD POSITION S T R A I G H T W A Y (P U B L I C W A Y - 4 0 ' W I D E ) 6" CAST IRON DRAIN INV = ±26'ΔΔ400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT IRON ROD SET 8" PERFORATED PIPE NOT OBSERVED LOCATION FROM RECORD PLANS(2) 1" ELECTRIC CONDUITS UNDERGROUND B-1 B-2 B-3 B-4 OW B-6 B-7 B-5 B-8 OW TBM TOP OF CONCRETE LIGHTPOLE BASE ELEV. = 31.77' TBM- WESTERLY HYDRANT FLANGE BOLT ELEV. = 24.36' TBM TOP OF CONCRETE PAD ELEV. = 32.49' EXISTING BOOSTER PUMP STATION 12.6' FENCE GATE (TYP.) EDGE OF WETLAND (TYP.) GRAVEL DRIVEWAY GATE INTERCOM GATE INTERCOM 18" DRAIN 8" DI WATER MAIN LOCATION APPROXIMATE EXISTING 10" AC WATER MAIN EXISTING 8" DI 8" DI WATER MAIN 8" DI WATER CB RIM= 21.2' NO VISIBLE INV GRAVEL BACKWASH BASIN BOTTOM ELEV. = ± 25.9' GATE MOTOR FROM BOOSTER TO HYDRANT TO TANK GRAVEL AREA EXISTING GAC CONTACTORS 12" DI WATER MAIN APPROXIMATE LOCATION OF COUPLING EXISTING 12" DI WATER MAIN PAVED DRIVEWAY PAVED DRIVEWAY EXISTING OVERFLOW SPILLWAY CHAI N L I N K F E N C E ( T Y P ) ACCESS GATE 30 27 28293132 CANDL E WI C K LANE APPRO X. R O W 10' SIDE YARD SETBACK20 ' FRONT YARD SETBACK 10' SIDE YAR D S E T B A C K WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 3220251617181921222324262 7 TBM CONCRETE BOUND 1 CONCRETE BOUND FOUND HELD POSITION ELEV: 23.12' TBM CONCRETE BOUND 3 CONCRETE BOUND FOUND ELEV. = 28.68' TBM CONCRETE BOUND 2 CONCRETE BOUND FOUND HELD POSITION ELEV: 21.03' C1-111 5 STRAIGHTWAY EXISTING CONDITIONS NOT FOR CONSTRUCTION SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' N MPS MD/MPS TB/GAA GAA - One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY 12/23/2024 12/23/2024 12/23/2024 303028292931312827252223242621201 9 1716163 0 30 28 29 25 22 2324 26 27 21 2 0 24 23 1 9 20 21 22 23 20 19 18 18 20 2531 2 930282 7 2 6 3332 3131313131 32 2 0 20201 9 19 2121 21222 3 26 252423 27 3 2313029 28 27 26 25 24 23 22 21 30 29 WF C-107WF C - 1 0 8 WF C-109 WF C-110 WF C-111 WF C - 1 1 3 WF C-1START WF C-3 WF C-2 WF C-4 WF C--5 WF C-6 WF C-7 WF C-8 WF C-9 WF C-102 WF C-103 WF C-104 WF C-105 WF C-106 EXISTING WATER STORAGE TANKGRAV E L D R IV EWA Y EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATIONWF C-115 WF C-116 WF C-117 WF C-118 43.9'38.6'27.5'FFE = ± 23.2'FFE = ± 23.9' FFE = ± 32.7' TREELINE (TYP)TREELINE (TYP)TREELINE (TYP) S T R A I G H T W A Y (P U B L I C W A Y - 4 0 ' W I D E )ΔΔ400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT B-1 B-2 B-3 B-4 OW B-6 B-7 B-5 B-8 OW EXISTING BOOSTER PUMP STATION 12.6' GRAVEL DRIVEWAY GRAVEL GRAVEL AREA 30 27 28293132 CANDL E WI C K LANE APPRO X. R O W WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 3220251617181921222324262 7 EXIST. 10" AC WATER MAIN TO BE ABANDONED IN PLACE CUT AND CAP EXISTING 8" PIPE ABANDON IN PLACE (SEE NOTE 1) CUT AND CAP EXISTING 8" PIPE ABANDON IN PLACE (SEE NOTE 1) EXTENT OF TREE CLEARING AND GRUBBING EXTENT OF TREE CLEARING AND GRUBBING (SEE NOTE 3) EXTENT OF TREE CLEARING AND GRUBBING (SEE NOTE 3) TEMPORARY SEDIMENT BASIN TEMPORARY SEDIMENT BASIN TEMPORARY SEDIMENT BASIN DISCHARGE TO BE ROUTED TO EAST TEMPORARY SEDIMENT BASIN LIMIT OF DISTURBANCE (TYP.) STRAW WATTLE (TYP.) GRAVEL DRIVEWAY TO BE REMOVED EXISTING CHLORINE SHED TO REMAIN FOR STORAGE (SEE NOTE 4.) EXISTING STRAIGHWAY FACILITY AND WELL TO REMAIN (SEE NOTE 4) EXISTING WATER STORAGE TANK TO REMAIN CONSTRUCTION VEHICLE EXIT REMOVE AND REUSE EXISTING HYDRANTS. HYDRANTS NOT USED UNDER THE CONTRACT SHALL BE RETURNED TO THE OWNER (TYP.) CONSTRUCTION VEHICLE EXIT EXISTING FENCE TO BE DEMOLISHED (SEE NOTE 2) EXISTING FENCE TO BE DEMOLISHED EXISTING ELECTRICAL TO BE REMOVED AND REINSTALLED PER E1-112 CUT AND CAP EXISTING 10" PIPE (SEE NOTE 1) CUT AND CAP EXISTING 8" PIPE REMOVE AND DISPOSE (SEE NOTE 1) CUT AND CAP EXISTING 8" PIPE REMOVE AND DISPOSE (SEE NOTE 1) EXISTING GAC FILTERS ON CONCRETE PAD TO BE WINTERIZED TREE CLEARING SHALL NOT OCCUR BETWEEN MARCH 15 AND OCTOBER 1 TREE CLEARING AND BUILDING DEMOLITION ACTIVITIES SHALL NOT OCCUR BETWEEN MARCH 15 AND OCTOBER 1 SILT SACK (TYP.) EXISTING 8" PIPES TO BE ABANDONED IN PLACE PLUG AND CAP EXISTING 8" TEES. 8" VALVES TO BE REMOVED AND RETURNED TO OWNER. PLUG AND CAP EXISTING 8" TEE CONSTRUCTION DEWATERING AREA CONSTRUCTION DEWATERING AREA C1-112 6 STRAIGHTWAY SITE DEMOLITION PLAN NOT FOR CONSTRUCTION SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' N MPS MD/MPS TB/GAA GAA - LIMITS OF TREE CLEARING AND GRUBBING (SEE NOTE 3) LEGEND: REMOVAL OF EXISTING GRAVEL DRIVE One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY REMOVAL OR ABANDONMENT OF EXISTING UTILITY NOTES: 1. CONTRACTOR SHALL REFER TO SPECIFICATION SECTION XXXXX FOR SEQUENCE OF CONSTRUCTION FOR DEMOLITION OF EXISTING PIPES AS REQUIRED TO MAINTAIN SERVICE TO EXISTING FACILITIES. ALL SHUTDOWNS WILL REQUIRE ADVANCE COORDINATION WITH ENGINEER, VEOLIA, AND HYANNIS WATER SYSTEM. SHUTDOWNS WILL NOT BE PERMITTED BETWEEN MAY 1 AND SEPT 1. 2. CONTRACTOR SHALL FIELD STAKE AND INSTALL TEMPORARY CONSTRUCTION FENCING ALONG ENTIRETY OF LIMIT OF DISTURBANCE WHERE VEHICULAR ACCESS IS NOT NECESSARY FOR OPERATIONS. CONSTRUCTION FENCING SHALL BE MAINTAINED THROUGHOUT THE DURATION OF CONSTRUCTION AND REMOVED UP FINAL COMPLETION OF SITE CONSTRUCTION. 3. TREE CLEARING SHALL NOT OCCUR BETWEEN MARCH 15 AND OCTOBER 1. 4. SELECTIVE DEMOLITION IS REQUIRED WITHIN THE EXISTING STRAIGHTWAY FACILITY. REFER TO SHEETS MX-XXX AND EX-XXX FOR ADDITIONAL INFORMATION. 5. DEWATERING AREAS ARE SHOWN IN EXPECTED LOCATIONS NEEDED FOR CONSTRUCTION AND ARE SUBJECT TO ADJUSTMENT BASED ON FIELD CONDITIONS WITHIN THE APPROVED LIMIT OF DISTURBANCE. 50' BUFFER ZONE MITIGATION CALCULATION CRITERIA AREA (SF) STRAIGHTWAY PROPOSED HARDSCAPE WITHIN 50' BUFFER 0 SF HYANNISPORT/SIMMONS POND PROPOSED HARDSCAPE WITHIN 50' BUFFER 1,047 SF STRAIGHTWAY PROPOSED HARDSCAPE WITHIN 50'-100' BUFFER 2,136 SF HYANNISPORT/SIMMONS POND PROPOSED HARDSCAPE WITHIN 50'-100' BUFFER 2,385 SF TOTAL PROPOSED NEW HARDSCAPE WITHIN BUFFER AREAS 5,568 SF AREA OF MITIGATION REQUIRED (MULTIPLIED BY 3)16,704 SF TOTAL PROPOSED RESTORATION AREA WITHIN 50' BUFFER 6,822 SF 12/23/2024 12/23/2024 12/23/2024 WF C-107WF C - 1 0 8 WF C-109 WF C-110 WF C-111 WF C - 1 1 3 WF C-1START WF C-3 WF C-2 WF C-4 WF C--5 WF C-6 WF C-7 WF C-8 WF C-9 WF C-102 WF C-103 WF C-104 WF C-105 WF C-106 EXISTING WATER STORAGE TANK EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATIONWF C-115 WF C-116 WF C-117 WF C-118 20" DEC 22" DEC 12" DEC 6" DEC 10" DEC 8" EVR10" EVR12" EVR 14" EVR 22" EVR 43.9'38.6'27.5'CHAINLINK FENCE (TYP)CHAI N L I N K F E N C E ( T Y P ) CHAINLINK FENCE (TYP) FFE = ± 23.2'FFE = ± 23.9' FFE = ± 32.7' S T R A I G H T W A Y (P U B L I C W A Y - 4 0 ' W I D E )ΔΔ400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT B-1 B-2 B-3 B-4 OW B-6 B-7 B-5 B-8 OW EXISTING BOOSTER PUMP STATION 12.6' FENCE GATE (TYP.) EDGE OF WETLAND (TYP.) CHAI N L I N K F E N C E ( T Y P ) CANDL E WI C K LANE APPRO X. R O W 10' SIDE YARD SETBACK20 ' FRONT YARD SETBACK 10' SIDE YAR D S E T B A C K WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 ESTIMATED FUTURE WELL REPLACEMENT LOCATION 400' ESTIMATED FUTURE WELLHEAD REPLACEMENT PROTECTION LIMIT BITUMINOUS DRIVEWAY NO PARKING STRIPING INFILTRATION BASIN B HANDICAP PARKING SPACE 20' WIDE DOUBLE ACCESS GATE ARBORVITAE VEGETATIVE SCREENING 25' 25' 25' 25' 25' PARKING SUBSURFACE CHAMBER INFILTRATION SYSTEM CURB CUT GRADE TO DRAIN TO STORMWATER TREATMENT AREA INFILTRATION BASIN A BITUMINOUS DRIVEWAY DUMPSTER, PAD, AND ENCLOSURE 5' STRIPED NO PARKING LANE AROUND BUILDING 18' (TYP.) 9' (TYP.) 5' 113' 88' 32' 33' 7' 33'66'46' CONCRETE PAD FOR CONDENSER UNITS SEE SHEETS S0-003 106' 68' 29' 60' 45' 10' 68' 56' 8' CHAIN LINK FENCE WITH BARBED WIRE (TYP.) 8' CHAIN LINK FENCE WITH BARBED WIRE (TYP.) SEDIMENT FOREBAY WITH STONE GABION WEIR RIPRAP OUTLET PROTECTION SEDIMENT FOREBAY WITH STONE GABION WEIR RIPRAP OUTLET PROTECTION EMERGENCY OVERFLOW WEIR WITH OUTLET PROTECTION 76' 32' 20' 14' WINTERIZED GAC BUILDING PAVED APRON FOR OVERHEAD DOOR VEHICULAR ACCESS ARBORVITAE VEGETATIVE SCREENING 25' 25' 45' 25' CAPE COD BERM (TYP.) STRAIGHTWAY WATER TREATMENT FACILITY APPROX. 11,000 SF FFE: 32' RIPRAP APRON CAPE COD BERM (TYP.) STEEL GUARDRAIL BOLLARDS @ 6' SPACING (TYP.) RECLAIM AND REPAVE EXISTING DRIVEWAY TO SHOWN EXTENT GAC WINTERIZATION BUILDING APPROX. 2,432 SF FFE 32.5' 4' HEIGHT CONCRETE BLOCK RETAINING WALL CUT AND PATCH UTILITY TRENCHES BOLLARDS (TYP.)R= 4 0' R =45'R=10 'R=50' R = 8 ' R =3'R=3'R=100'R=125'R =5 'R=5'R=20 ' R=3' 9' ELECTRICAL TRANSFORMER 115' SIDE YARD SETBACK31 8 ' F R O N T Y A R D SE T B A C K CHAIN LINK FENCE WITH PRIVACY SLATS 597' REA R Y A R D S E T B A C K BOLLARD MOUNTED HANDICAP PARKING SIGN R =5 0 'R=5'R=8 'R=75' R =5'7' SIDEWALK (TYP.) R=100' R=10' FULL DEPTH SAWCUT FULL DEPTH SAWCUT ZONING CHART (ZONE: RB) CRITERIA REQUIREMENT PROVIDED LOT SIZE (AC)1.0 AC MIN.14.8 AC LOT FRONTAGE (FT)20' MIN.145' LOT WIDTH (FT)100' MIN.900' FRONT YARD SETBACK (FT)20' MIN.318' SIDE YARD SETBACK (FT)10' MIN.115' REAR YARD SETBACK (FT)10' MIN.597' PARKING CHART (USE: PUBLIC UTILITY) CRITERIA REQUIREMENT PROVIDED TOTAL NUMBER OF PARKING SPACES AS DETERMINED BY BUILDING COMMISSIONER 12 TOTAL NUMBER OF ADA SPACES 1 1 C1-113 7 STRAIGHTWAY OVERALL SITE PLAN NOT FOR CONSTRUCTION SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' N MPS MD/MPS TB/GAA GAA - STORMWATER MANAGEMENT AREA PAVED DRIVEWAY NO PARKING STRIPING RIPRAP CONCRETE LEGEND: One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY EXISTING DRIVEWAY RECLAMATION 12/23/2024 12/23/2024 12/23/2024 303028292931312827252223242621201 9 1716163 0 30 28 29 25 22 2324 26 27 21 20 24 23 1 9 20 21 22 23 20 19 18 18 20 2531 2 930282 7 2 6 3332 3131313131 32 2 0 20201 9 19 2121 21222 3 26 252423 27 3 2313029 28 27 26 25 24 23 22 21 30 29 WF C-107WF C - 1 0 8 WF C-109 WF C-110 WF C-111 WF C - 1 1 3 WF C-1START WF C-3 WF C-2 WF C-4 WF C--5 WF C-6 WF C-7 WF C-8 WF C-9 WF C-102 WF C-103 WF C-104 WF C-105 WF C-106 EXISTING WATER STORAGE TANK EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATIONWF C-115 WF C-116 WF C-117 WF C-118 20" DEC 22" DEC 12" DEC 6" DEC 10" DEC 8" EVR10" EVR12" EVR 14" EVR 22" EVR 43.9'38.6'27.5'FFE = ± 23.2'FFE = ± 23.9' FFE = ± 32.7' S T R A I G H T W A Y (P U B L I C W A Y - 4 0 ' W I D E )ΔΔ400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT B-1 B-2 B-3 B-4 OW B-6 B-7 B-5 B-8 OW EXISTING BOOSTER PUMP STATION 12.6' 30 27 28293132 CANDL E WI C K LANE APPRO X. R O W WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 3220251617181921222324262 7 32.40 30.88 31.92 31.65 80 LF -18" HDPE S = 0.01 FT/FT 22 LF -12" HDPE S = 0.021 FT/FT 6 LF -12" HDPE S = 0.01 FT/FT 12 LF -12" HDPE S = 0.03 FT/FT 8 LF - 6" DI S = 0.01 FT/FT 31.60 30.90 30.10 30.90 31' 30' 29' 28' 27' 26' 25' 24' 23'31'30'30' 29' 28' 27' 26' 25' 24' 23' 22' 31' 2 5 ' 2 0 ' 3 1 ' 24' 21' 20'30'28'29' 31'31'31.60 31.50 31.20 31.50 31.6 32' 31.95 31.95 31.95 31.95 31.95 31.9531.95 31.80 30.40 22.00 22.40 22.20 23'26'162 LF -18" HDPES = 0.025 FT/FT38 LF -12" HDPES = 0.01 FT/FT31.60 29'28' 29'114 LF -12" HDPES = 0 .007 FT /FT32'33 LF -12" HDPE S = 0.03 FT/FT ESTIMATED FUTURE WELL REPLACEMENT LOCATION 400' ESTIMATED FUTURE WELLHEAD REPLACEMENT PROTECTION LIMIT INFILTRATION BASIN A 7,710 CF STORAGE INFILTRATION BASIN B 8,348 CF STORAGE RETAINING WALL TOP: 30.0' MAX. BOTTOM: 26.0' 4' DIA. DEEP SUMP CATCH BASIN RIM ELEV. 25.8' 12" HDPE INV. ELEV. 22.8' TRENCH DRAIN GRATE ELEV. 30.1' 12" HDPE INV. ELEV. 27.1' 4' DIA. DEEP SUMP CATCH BASIN RIM ELEV. 27.9' 12" HDPE INV. ELEV. 25.5' 4' DIA. DEEP SUMP CATCH BASIN RIM ELEV. 23.1' 8" HDPE INV. ELEV. 20.9' UNDERGROUND INFILTRATION SYSTEM APPROX. 384 CF STORAGE 8" HDPE INV ELEV. 20.5' EMERGENCY OVERFLOW WEIR WITH OUTLET EROSION PROTECTION ELEV. 23.0' RIPRAP EROSION CONTROL OUTLET PROTECTION APRON (TYP.) GABION BASKET WEIR 4' DIA. MANHOLE RIM ELEV. 30.20' A) 12" HDPE INV. ELEV. 26.7' B) 12" HDPE INV. ELEV. 24.0' 4' DIA. MANHOLE RIM ELEV. 26.20' A) 12" HDPE INV. ELEV. 22.4' B) 18" HDPE INV. ELEV. 22.2' C) 18" HDPE INV. ELEV. 22.4' SEDIMENT FOREBAY GABION BASKET WEIR TOP ELEV: 24.0' 5' DIA. DOUBLE GRATE DEEP SUMP CATCH BASIN RIM ELEV. 30.1' 18" HDPE INV. ELEV. 26.5' 12" HDPE FLARED END SECTION INV. ELEV. 23.0' 18" FLARED END SECTION INV. ELEV. 22.0' SEDIMENT FOREBAY TOP ELEV. 23.0' EMERGENCY OVERFLOW WEIR WITH OUTLET EROSION PROTECTION INV. ELEV. 24.0' GRADE CURB CUT TO DRAIN TO SEDIMENT FOREBAY 35' STRAIGHTWAY WATER TREATMENT FACILITY APPROX. 11,000 SF FFE: 32' GAC WINTERIZATION BUILDING APPROX. 2,432 SF FFE 32.5' 4' DIA. MANHOLE RIM ELEV. 32.00' A) 18" HDPE INV. ELEV. 28.0' B) 18" HDPE INV. ELEV. 24.0' C) 6" DI INV. ELEV. 29.0' 18" HDPE FLARED END SECTION INV. ELEV. 23.0' 45° 6" DI BEND 4' DIA. MANHOLE RIM ELEV. 25.3' A) 12" HDPE INV. ELEV. 20.6' B) 12" HDPE INV. ELEV. 20.5' 4' DIA. DRYWELL RIM. ELEV. 31.9' INV: 30.0' B A C B A A B A B C 12" HDPE FLARED END SECTION INV. ELEV. 22.0' 12" DI OUTLET WITH EROSION PROTECTION APRON INV. ELEV. 23.0' 12" DI 45° BEND 4' DIA. MANHOLE RIM ELEV. 27.8' 12" HDPE INV. ELEV. 23.0' 11LF - 4" PVC S= 0.01 FT/FT INV: 30.1' BACKWASH TANK OVERFLOW/DISCHARGE C1-114 8 STRAIGHTWAY GRADING PLAN NOT FOR CONSTRUCTION SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' N MPS MD/MPS TB/GAA GAA One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY GRADING VOLUMES CHART EARTHWORK TYPE VOLUME (CUBIC YARD) CUT 1,657 CY FILL 3,508 CY NET VOLUME 1,851 CY FILL NOTES: 1. GRADING VOLUMES CHART PROVIDES OVERALL VOLUMES WITHOUT ACCOUNT FOR SWELL, COMPACTION, DISPOSAL, OR MATERIAL IMPORT. CONTRACTOR SHOULD NOT EXCLUSIVELY RELY UPON THESE NUMBERS FOR BIDDING. 12/23/2024 12/23/2024 12/23/2024 WF C-107WF C - 1 0 8 WF C-109 WF C-110 WF C-111 WF C - 1 1 3 WF C-1START WF C-3 WF C-2 WF C-4 WF C--5 WF C-6 WF C-7 WF C-8 WF C-9 WF C-102 WF C-103 WF C-104 WF C-105 WF C-106 EXISTING WATER STORAGE TANK EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATIONWF C-115 WF C-116 WF C-117 WF C-118 43.9'38.6'27.5'TRANSFORMER UNDERGROUND ELECTRIC LOCATION APPROXIMATE EMH NO ACCESS EXISTING GAS LINE LOCATION APPROXIMATE EMH (2) 2.5" PVC CONDUITS IN/OUT FFE = ± 23.2'FFE = ± 23.9' FFE = ± 32.7' EMH NO ACCESS EMH (6) 2.5" PVC CONDUITS IN/OUT UNDE R G R O U N D E L E C T R I C L O C A T I O N A P P R O X I M A T E FRO M R E C O R D P L A N S S T R A I G H T W A Y (P U B L I C W A Y - 4 0 ' W I D E )ΔΔ400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT (2) 1" ELECTRIC CONDUITS UNDERGROUND B-1 B-2 B-3 B-4 OW B-6 B-7 B-5 B-8 OW EXISTING BOOSTER PUMP STATION 12.6' 8" DI WATER MAIN LOCATION APPROXIMATE EXISTING 8" DI CANDL E WI C K LANE APPRO X. R O W WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/238'' BW 8'' BW 8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW2'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W 8'' BW 8'' BW 8'' BW8'' BW8'' BW8'' BW8'' BW 12'' RW12'' RW12'' W12'' W12'' W16'' RW 16'' W 16'' W 16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 5/8'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RWESTIMATED FUTURE WELL REPLACEMENT LOCATION 400' ESTIMATED FUTURE WELLHEAD REPLACEMENT PROTECTION LIMIT 16" DI WATER MAIN 2,500 GALLON DOUBLE WALLED TIGHT TANK WITH LEAK DETECTION SEE C1-116 AND C1-151 12" DI POST-GAC WATER 12" DI PRE-GAC WATER FINISHED WATER TO CONTACT TANK 8" DI BACKWASH SUPPLY 12" DI RAW WATER MAIN 16" DI RAW WATER MAIN 4" DI FIRE SERVICE LINE UNDERGROUND ELECTRIC (TYP.) SEE E-009 ELECTRIC HANDHOLE (TYP.) SEE E-009 16" DI FINISHED WATER MAIN 12" DI RAW WATER MAIN 16" X 12" X 12" TEE 4" DI 45° BEND 8" DI 45° BEND 16" DI 45° BEND 16" DI 45° BEND 12" DI 45° BEND (2) 16" DI 22.5° BEND 16" DI 11.25° BEND 16" DI 11.25° BEND INSET - GAC UTILITIES 8" DI BACKWASH WASTE 12" DI WATER MAIN STRAIGHTWAY WATER TREATMENT FACILITY APPROX. 11,000 SF FFE: 32' GAC WINTERIZATION BUILDING APPROX. 2,432 SF FFE 32.5' TRANSFORMER SEE PLAN E1-112 GAC BACKWASH LINE TO RUN BENEATH BACKWASH SUPPLY LINE SEE SHEET M1-211 16" DI 45° BEND DRYWELL FOR SINK DRAIN INSET - STWY UTILITIES EAST INSET - STWY UTILITIES WEST INSET - STWY WATER CONNECTION 1 INSET - STWY WATER CONNECTION 2 SAMPLE TAP AND 5 8" POLYPIPE C1-115 9 STRAIGHTWAY UTILITIES PLAN NOT FOR CONSTRUCTION SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' N MPS MD/MPS TB/GAA GAA One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY NOTE: 1. INSETS IDENTIFIED ON THIS SHEET ARE LOCATED ON C1-116 12/23/2024 12/23/2024 12/23/2024 EMH NO ACCESS EMH (2) 2.5" PVC CONDUITS IN/OUT FFE = ± 32.7' EMH NO ACCESS EMH (6) 2.5" PVC CONDUITS IN/OUT GRAV E LDR IV EWA Y 12'' W 12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W8'' BW8'' BW 8'' BW 8'' BW 8'' BW 8'' BW 8'' BW 8' ' BW 8'' BW8'' BW8'' BW12'' W 12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W8'' W8'' W400' ESTIMATED FUTURE WELLHEAD REPLACEMENT PROP. WINTERIZED GAC BUILDING FFE = 32.5' 6" DI PIPE 6" GATE VALVE 8"X8"X8" DI TEE 6" DI CAP 12" 45° BENDS (6) 6" GATE VALVES (4) 6" x 12" REDUCER (4) 6" HYDRANT AND GATE VALVE (2) CONNECT EXISTING BELOW GRADE DI PIPE TO EXISTING ABOVE GRADE HDPE 12" WYE (2) 8" GATE VALVE (2) INSTALL FLOW METER ON BACKWASH SUPPLY LINE 6" 90° BEND LAGOON PIPING TO BE CAPPED AND PLUGGED AFTER INSTALLATION OF BACKWASH TANK REMOVE AND REINSTALL ELECTRIC CONDUIT AND MANHOLES PER E1-101 8" DI 45° BEND (2) 12" DI TEE 12" x 8" DI REDUCER SEE SHEETS M1-211 AND M1-212 FOR GAC INTERNAL PIPING EXISTING EMH TO REMAIN EXISTING WATER STORAGE TANK EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATION8'' BW 8'' BW8'' BW8'' BW8'' BW12'' W12'' W8'' BW8'' BWBENS POND 12'' RW12'' W16'' W 16'' W16'' W16'' W16'' W16'' W12'' W12'' W12'' W16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 4'' W4'' W4'' W4'' W4'' W12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RWINSET - GAC UTILITIES INSET - STWY UTILITIES EAST INSET - STWY UTILITIES WEST INSET - STWY WATER CONNECTION 1 INSET - STWY WATER CONNECTION 2 TREELINE (TYP ) 400' WELLHEAD PROTECTION LIMITGRAVE LDRIV EWA Y BACKWASH BASIN BOTTOM ELEV. = ± 25.9' GRAVEL AREA8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8' ' BW 8'' BW 8'' BW2'' W2'' W2'' W2'' W2'' W 2'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W 12'' W 12'' W 12'' W8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW8'' BW 8'' BW 8'' BW12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W 12'' W 12'' W 12'' W 12'' W 4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W4'' W12" DI POST-GAC WATER 12" DI PRE-GAC WATER 8" DI 45° BEND (4) 4" DI 45° BEND 6" CAST IRON 45° BEND (2) 8" DI BACKWASH WASTE GAC BACKWASH LINE TO RUN BENEATH BACKWASH SUPPLY LINE SEE SHEET M1-211 4" DI WYE 4" X 2" DI REDUCER 2" POLYPIPE DRINKING WATER SUPPLY 8" GATE VALVE (4) 4" GATE VALVE 12" DI 45° BEND (4) BUILDING SEWER INV. ELEV: 28.5' ELECTRICAL CONDUIT TO HIGH LEVEL ALARM AND LEAK DETECTION ALARM PANEL LOCATION 12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW12'' RW16'' RW 16'' RW 16'' RW 16'' RW16'' W16'' W16'' W16'' W16'' W16'' W16'' W 12'' RW12'' RW12'' RW12'' RW16" DI RAW WATER MAIN 8" 90° BEND 12" x 8" REDUCER 16"X16"X16" TEE 12" GATE VALVE 12" GATE VALVE 16" DI 45° BEND (2) 16"X12" REDUCER 16"X12" REDUCER 16" GATE VALVE (2) GATE INTE R C O M 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16" GATE VALVE 16" DI 11.25° BEND 16"X16"X16" TEE CONNECTION TO EXISTING MAIN EXISTING 10" AC WATER MAIN CB RIM= 21.2' NO VISIBLE INV GRAVEL FROM BOOSTER TO HYDRANT APPROXIMATE LOCATION OF COUPLING 8'' BW8'' BW 8'' BW 8'' BW8'' BW 12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W12'' W16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 16'' W 4'' W4'' W4'' W 4'' W 8" X 12" X 12" TEE 4" X 12" X 12" TEE 8" GATE VALVE 4" GATE VALVE 4" DI 45° BEND 8" DI 45° BEND 12" X 12" X 12" TEE 12" DI WATER MAIN 16" X 12" REDUCER C1-116 10 STRAIGHTWAY UTILITIES INSET PLAN NOT FOR CONSTRUCTION SCALE IN FEET 0 70 140 210 SCALE: 1" = 70' N MPS MD/MPS TB/GAA GAA SCALE: 1" = 10' INSET - GAC UTILITIES One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY SCALE: 1" = 10' INSET - STWY UTILITIES WEST SCALE: 1" = 10' INSET - STWY UTILITIES EAST SCALE: 1" = 10' INSET - STWY WATER CONNECTION 1 SCALE: 1" = 60' STRAIGHTWAY INSET KEY PLAN SCALE: 1" = 10' INSET - STWY WATER CONNECTION 2 12/23/2024 12/23/2024 12/23/2024 3030293131TREELINE (TYP) 400' WELLHEAD PROTECTION LIMIT 3029 328'' BW8' ' BW 8'' BW 8'' BW8'' BW8'' BW8'' BW 8'' BW 8'' BW 1+20 0+001+00 30.90 31.60 31.95 31.95 31.95 31' 30.40 2,500 GALLON DOUBLE WALLED TIGHT TANK WITH LEAK DETECTION RIM ELEV. 31.0' CLEANOUT RIM ELEV. 31.6' 6" CAST IRON 45° BEND (2) 6" PVC PIPE OR APPROVED EQUAL 6" CAST IRON WYE TRANSITION FROM 6" CI PIPE TO 6" PVC 10' FROM BUILDING USING FERNCO COUPLING OR SIMILAR TIGHT TANK WILL VENT THROUGH THE BUILDING STACK ENCASE SEWER LINE IN CONCRETE FROM BUILDING TO 10' PAST DRAIN CROSSING STRAIGHTWAY WATER TREATMENT FACILITY APPROX. 11,000 SF FFE: 32' BUILDING SEWER INV. ELEV: 28.5' 8' ELECTRICAL CONDUIT TO HIGH LEVEL ALARM AND LEAK DETECTION ALARM PANEL LOCATION LENGTH OF PIPE TO BE WRAPPED WITH POLYETHYLENE ENCASEMENT TUBING (POLYWRAP) 2,500 GALLON TIGHT TANK SEE DETAIL SHEET C1-151 BUILDING SEWER INV=28.5' 2,500 GAL TIGHT TANK RIMS=31.0'± INV. IN=27.8' (BUILDING) PROPOSED GRADE EXISTING GRADE CLEANOUT ELEV. 31.6' INV. 28.4' 74 LF - 6" PVC S=0.01 FT/FT 10 LF - 6" CI S=0.01 FT/FT PIPE MATERIAL TRANSITION EXISTING WATER STORAGE TANK EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATION43.9'38.6'27.5'FFE = ± 23.2' FFE = ± 23.9' FFE = ± 32.7' 400' WELLHEAD PROTECTION LIMIT EXISTINGBOOSTERPUMPSTATION12.6' 1+20 0+001+00 ESTIMATED FUTURE WELL REPLACEMENT LOCATION 403' BETWEEN TIGHTTANK AND WELL329' BETWEEN TIGHT TANK ANDESTIMATED FUTURE WELL LOCATIONC1-117 11 STRAIGHTWAY SEWER PLAN NOT FOR CONSTRUCTION SCALE: 1" = 10' STRAIGHTWAY TIGHT TANK PLAN SCALE IN FEET 0 10 20 30 SCALE: 1" = 10' N MPS MD/MPS TB/GAA GAA TIGHT TANK NOTES: 1.THE PROPOSED DESIGN COMPLIES WITH TITLE 5 REQUIREMENTS AND SHALL BE INSTALLED AS SHOWN. 2.THE PROPOSED SYSTEM SHALL BE INSTALLED BY A TITLE V LICENSED SEPTIC INSTALLER LISTED ON THE TOWN OF BARNSTABLE' MOST CURRENT LIST OF LICENSED SEPTIC INSTALLERS. 3.THE BARNSTABLE ELECTRICAL INSPECTOR SHALL BE NOTIFIED AT LEAST 36 HOURS PRIOR TO INSTALLATION OF THE ALARM SYSTEM AND ASSOCIATED ELECTRICAL COMPONENTS. 4.THE BARNSTABLE STRAIGHTWAY WELL IS 403 FEET FROM THE TIGHT TANK. 5.THE TIGHT TANK IS OUTSIDE OF THE 400-FOOT RADIUS OF THE MASSDEP ZONE I PROTECTIVE AREA SURROUNDING THE WELL. 6.THE TOWN HAS IDENTIFIED AN APPROXIMATE AREA FOR THE INSTALLATION OF A REPLACEMENT WELL. THE TIGHT TANK IS APPROXIMATELY 329' FROM THIS AREA. THE REPLACEMENT WELL WILL NOT BE INSTALLED AS PART OF THIS PROJECT. 7.THERE ARE NO WETLANDS WITHIN 100 FEET OF THE TIGHT TANK. 8.THE PROPOSED TIGHT TANK WILL SERVE A PUBLIC WATER SUPPLY FACILITY WHERE IT IS NOT FEASIBLE TO CONNECT TO A PUBLIC SEWER. 9.THE PROJECT IS SUBJECT TO REVIEW AND APPROVAL BY THE BARNSTABLE CONSERVATION COMMISSION. THE SIZING OF THE TANK WAS DETERMINED IN ACCORDANCE WITH TITLE 5. THE ASSOCIATED CALCULATIONS ARE BELOW: DAILY SEWAGE FLOW USE: FACTORY, INDUSTRIAL PLANT, NO CAFETERIA DAILY DESIGN FLOW = 15 GPD PER EMPLOYEE DAILY FLOW (REQUIRED) 15 GPD X 2 EMPLOYEES TOTAL DAILY FLOW WELL 3 TREATMENT FACILITY = 30 GPD TIGHT TANK 2,500 GALLON TANK MUST CONTAIN 500% OF SEPTIC REQUIREMENTS PER 310 CMR 15.203 48-HOUR STORAGE CAPACITY IN COMPARTMENT 30 GPD X 2 DAYS = 60 GALLONS STORAGE REQUIRED 500% OF 60 GALLONS = 300 GALLONS 2000-GALLON MINIMUM TANK SIZE PER 310 CMR 15.260 TOTAL STORAGE:2,500 GALLONS > 2,000 GALLONS HORIZONTAL SCALE: 1" = 10' STRAIGHTWAY TIGHT TANK PROFILE VERTICAL SCALE: 1" = 2'SCALE: 1" = 40' STRAIGHTWAY TIGHT TANK LOCATION PLAN One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY SCALE IN FEET 0 10 20 30 SCALE: 1" = 10' SCALE IN FEET 0 40 80 120 SCALE: 1" = 40' 12/23/2024 12/23/2024 12/23/2024 C1-151 12 STRAIGHTWAY SEWER DETAILS - I NOT FOR CONSTRUCTION MPS MD/MPS TB/GAA GAA N.T.S. TIGHT TANK TYPICAL DETAIL THE REQUIRED BUOYANCY CALCULATIONS IN ACCORDANCE WITH TITLE 5 ARE BELOW: ASSUMPTIONS/INITIAL INFORMATION: GROUNDWATER AT ELEVATION 18 PER SHGWT TANK EVALUATED FULLY SUBMERGED EARTH COVER DEPTH = 24 INCHES WEIGHT OF EARTH = 110 PCF WEIGHT OF WATER = 62.4 PCF OUTER TANK AREA = 74.2 SF (SEE CALC THIS PAGE) WEIGHT OF TANK (2,500-GALLON TANK EMPTY PER MANUFACTURER) = 2,200 LBS WEIGHT OF 12' DEADMAN (12" X 12" CROSS SECTION PER MANUFACTURER) = 1,800 LBS DEADMAN AREA (TOP FACE) = 1' X 12' = 12 SF BUOYANCY CALCULATION USING OUTER TANK DIMENSIONS WEIGHT OF EARTH ON TANK = (TANK AREA * EARTH COVER) * (WEIGHT OF EARTH) = (74.2 SF * 2') * (110 PCF) = 16,324 LBS WEIGHT OF TANK + WEIGHT OF EARTH ON TANK = 18,524 LBS. WEIGHT OF EARTH ON DEADMAN = (DEADMAN AREA * EARTH COVER) * (WEIGHT OF EARTH) = (12 SF * 7') * (110 PCF) = 9,240 LBS TOTAL SYSTEM WEIGHT = WEIGHT OF TANK + TANK WEIGHT OF EARTH + 2 * (WEIGHT OF DEADMAN + DEADMEN WEIGHT OF EARTH) = 18,524 LBS + 2*(1,800 LBS + 9,240 LBS) = 40,604 LBS HYDROSTATIC PRESSURE = (TANK AREA X SHGW HEIGHT) * (WEIGHT OF WATER) + (DEADMAN AREA * SHGW HEIGHT) * (WEIGHT OF WATER) = (74.2 SF * 6') * (62.4 PCF) + (12.0 SF * 1') * (62.4) = 28,528 LBS HYDROSTATIC PRESSURE = 28,528 LBS < 40,604 LBS <= TOTAL SYSTEM WEIGHT (OK) THE ALARM HEIGHT WAS SET AT THE VOLUME AT WHICH THE TANK WILL CONTAIN 2,000 GALLONS OF WASTEWATER AS CALCULATED BELOW: ALARM HEIGHT PER MANUFACTURER SPECIFICATIONS, TANK VOLUME IS EQUAL TO 2,000 GALLONS 55-5 8" ABOVE THE BOTTOM OF THE TANK. 55-5 8" = 4.64' ABOVE THE BOTTOM OF THE TANK One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY 13' 5 3 4 " 7' 2 1 4" 6' O.D. 3' 1 3 4" THE MAXIMUM CROSS-SECTIONAL AREA OF THE TANK WHEN VIEWED FROM ABOVE IS CALCULATED BELOW. THIS AREA IS USED TO CALCULATE SOIL PRESSURE AND HYDROSTATIC PRESSURE. AREA OF END CAP: IDEALIZED AS A HALF CIRCLE CROSS SECTION RADIUS = 3' 1 3 4" = 3.15' AREA = (π*R^2)/2 = (π*(3.15')^2)/2 = 15.55 SF AREA OF TANK BODY: RECTANGULAR CROSS SECTION L = 7' 2 1 4" = 7.19' W = 6' AREA = L*W = (7.19' * 6') = 43.1 SF TOTAL CROSS SECTIONAL AREA: AREA = (2* END CAP AREA) + (TANK BODY AREA) = 2*(15.55) SF + 43.1 SF = 74.2 SF TANK BODY END CAPEND CAP PLAN VIEW N.T.S. TIGHT TANK PLAN VIEW TYP. MANUFACTURER DETAIL FOR 2,500 GALLON DOUBLE WALL FIBERGLASS TIGHT TANK 12' PREFABRICATED CONCRETE DEADMENF2 D XX"DIA SW CONTAINMENT COLLAR & 36"HIGH SW SUMP WITH 22"DIA MANWAY WITH 5-4"NPT FITTINGS IN COVER & STRIKER PLATE 4"NPT SERVICE FITTING WITH STRIKER PLATE 4"NPT MONITOR FITTING WITH HYDROSTATIC MONITORING RESERVOIR LIFTING LUG A B C E HOLD DOWN STRAP LOCATION ITEM QTY DESCRIPTION 1 1 1 1 2 2 -00 -- 1 D DRN DATE CHK'D DATE APPR'D DATE SCALE:SHT OF DR. NUMBER REV TITLE DR. SIZE 0 DATE CHK'D REVISION DESCRIPTION - DATEDRN - DATE ----- APPR'D 1 6'DIA DW CAP. 2,500 GALLONS - R D A 1 2 E F 3' 1 3 4 "5' 9" 6'-0" O.D. SHELL 6'-3 1/2" O.D. RIBS 3 4 1' 5 3 4" (TYP) E 13' 5 3 4 " B C 12' NOTE: 1 - PREFABRICATED DEADMEN SHOWN. ACCOMMODATIONS MAY BE REQUIRED TO SECURE THE STRAPS TO THE DEADMEN. SEE DETAIL NEXT SHEET 2 - NOMINAL TANK WEIGHT: 2,200 LBS N.T.S. 3"10" TYP. SUPPORT CLAMP w/ ST/ST ROD & CLAMP 4" PVC INLET 4" PVC TEE 6" 3" MIN. AIR SPACE FINISH GRADE ELEV = 31.0' HIGH LEVEL ALARM AT 2,000 GAL VOLUME ON - INV=27.64' CONDUIT TO BUILDING ELECTRICAL (ELECTRIC BOX MUST BE LOCATED OUTSIDE OF TANK RISER) FLOAT ASSEMBLY CONNECTED TO LIQUID LEVEL ALARM PANEL BY ORENCO, OR APPROVED EQUAL PRECAST 12' DEADMAN DEADMAN ANCHOR STRAP PRECAST 12" DEADMAN DEADMAN ANCHOR STRAP FINISH GRADE ELEV = 31.0' 1' 12' DEADMAN SHALL BE PLACED OUTSIDE OF "TANK SHADOW" "TANK SHADOW"BOTTOM OF DEADMAN ELEVATION SHALL BE EQUAL TO OR LOWER THAN TANK BOTTOM ELEVATION TOP OF TANK BODY ELEV. = 29.0' TANK BOTTOM AND MAX. DEADMAN BOTTOM ELEV. =23.0' TOP OF DEADMAN MAX. ELEV. = 24.0' SET UNIT LEVEL ON 12" OF 3/4" - 1-1/2" CRUSHED STONE PLACED IN 4" LIFTS COMPACTED TO 95% PROCTOR N.T.S. TYPICAL PRECAST DEADMAN DETAIL N.T.S. TYPICAL PRECAST DEADMAN ANCHOR DETAIL 12/23/2024 12/23/2024 12/23/2024 C1-152 13 STRAIGHTWAY SEWER DETAILS - II NOT FOR CONSTRUCTION MPS MD/MPS TB/GAA GAA GENERAL CONSTRUCTION REQUIREMENTS FOR ALL TIGHT TANK SYSTEM COMPONENTS 1.TIGHT TANK: (A) WATERTIGHT THROUGH MANUFACTURER'S SPECIFICATION AND WARRANTY; OR (B) MADE WATERTIGHT BY THE MANUFACTURER, EQUIPMENT SUPPLIER OR INSTALLER USING SYNTHETIC POLYMER SEALER SPECIFIED BY THE SYNTHETIC MATERIAL MANUFACTURER. 2.TIGHT TANK SHALL BE CONSTRUCTED OR SET LEVEL AND TRUE TO GRADE ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY COMPACTED. IF THE COMPONENT IS PLACED IN FILL, PROPER COMPACTION IS REQUIRED TO ENSURE STABILITY AND TO PREVENT SETTLING; NATIVE GROUND WITH A SIX INCH AGGREGATE BASE IS OTHERWISE ADEQUATE. 3.TIGHT TANK SHALL BE EQUIPPED WITH A WATERTIGHT ACCESS MANHOLE(S) WITH A MINIMUM DIAMETER OF 22 INCHES AND CONSTRUCTED OF DURABLE MATERIAL. 4.ALL SYSTEM COMPONENTS SHALL BE CONSTRUCTED OF CORROSION RESISTANT MATERIALS. 5.ALL PRESSURIZED PIPES SHALL BE DESIGNED AND INSTALLED TO MEET THE FOLLOWING REQUIREMENTS: (A) TO PREVENT FREEZING BY BEING INSTALLED BELOW THE FROST LINE, BY BEING ADEQUATELY INSULATED IF INSTALLED ABOVE THE FROST LINE, OR BE SELF-DRAINING; (B) TO SPECIFY THE APPROPRIATE CLASS OR SCHEDULE OF PIPE TO WITHSTAND MAXIMUM PRESSURE AND/OR ANTICIPATED VEHICULAR LOADS; AND (C) TO SPECIFY APPROPRIATE THRUST BLOCKING AT ALL ANGLES, BENDS, BRANCHES, PLUGS AND WHEREVER ELSE NECESSARY TO PREVENT DISRUPTION OF PROPER FUNCTIONING OF THE LINE. 6.THE TOP OF ALL SYSTEM COMPONENTS, INCLUDING THE TIGHT TANK SHALL BE INSTALLED NO MORE THAN 36" BELOW FINISH GRADE. 7.WHERE ANY PORTION OF ANY COMPONENT IS TO BE PLACED AT OR BELOW THE GROUND-WATER TABLE, ALL SYSTEM TANKAGE, INCLUDING THE TIGHT TANK, SHALL BE DESIGNED WITH COUNTER WEIGHTS, ANCHORS OR BALLAST AND A BUOYANCY CALCULATION FOR THE ENTIRE VOLUME OF EACH COMPONENT, WHEN EMPTY, SHALL BE PERFORMED AND SUBMITTED WITH THE SYSTEM PLANS AND SPECIFICATIONS. 8.ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. BUILDING SEWERS SPECIFICATIONS 1.THE BUILDING SEWER SHALL BE SUFFICIENT TO SERVE THE CONNECTED FIXTURES. IN NO CASE SHALL THE BUILDING SEWER BE LESS THAN FOUR INCHES IN DIAMETER. 2.THE BUILDING SEWER SHALL BE CONSTRUCTED OF CORROSION RESISTANT MATERIAL AND EQUIPPED WITH WATER TIGHT JOINTS; PVC PIPE OR THE EQUIVALENT. BUILDING SEWER SHALL BE CAST IRON PIPING FOR THE FIRST 10' OF PIPING FROM THE BUILDING. 3.ALL PIPE JOINTS OF THE BUILDING SEWER SHALL BE MADE WATER-TIGHT AND PROTECTED AGAINST DAMAGE BY ROOTS. POURED-TYPE JOINTS SHALL BE PROPERLY WIPED ON THE INSIDE TO ELIMINATE OBSTRUCTION OF FLOW. 4.THE BUILDING SEWER SHALL BE LAID ON A COMPACTED FIRM BASE. 5.THE BUILDING SEWER SHALL BE VENTED THROUGH THE VENT STACK OR MAIN VENT OF THE BUILDING SERVED BY IT. NO TRAP SHALL BE INSTALLED IN THE BUILDING SEWER OR BUILDING DRAIN. 6.ALL BUILDING SEWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE STATE PLUMBING CODE, 248 CMR2.00 TIGHT TANK SPECIFICATIONS 1.TIGHT TANKS SHALL BE CONSTRUCTED OF SOUND AND DURABLE WATERTIGHT MATERIALS NOT SUBJECT TO EXCESSIVE CORROSION, DECAY, OR FROST DAMAGE, OR CRACKING OR BUCKLING DUE TO SETTLEMENT OR BACKFILLING. TIGHT TANKS SHALL BE DOUBLE WALLED FIBERGLASS REINFORCED PLASTIC. (OTHER MATERIALS AS APPROVED IN WRITING BY THE DEPARTMENT, METAL TIGHT TANKS ARE PROHIBITED.) 2.TANK CONSTRUCTION MATERIALS SHALL MEET THE FOLLOWING MINIMUM SPECIFICATIONS OR AN ASTM EQUIVALENT STANDARD: 2.1.INTERNAL LOAD - TANK SHALL BE DESIGNED TO WITHSTAND A 5-PSIG (35 kPA) AIR-PRESSURE TEST WITH 5:1 SAFETY FACTOR. 2.2.SURFACE LOADS - TANK SHALL BE DESIGNED TO WITHSTAND SURFACE H-20 AND HS-20 AXLE LOADS WHEN PROPERLY INSTALLED ACCORDING TO MANUFACTURER'S CURRENT INSTALLATION AND OPERATING GUIDELINES. 2.3.EXTERNAL HYDROSTATIC PRESSURE - TANK SHALL BE DESIGNED FOR 7 FEET OF OVERBURDEN OVER THE TOP OF THE TANK, THE HOLE FULLY FLOODED, AND A SAFETY OF 5:1 AGAINST GENERAL BUCKLING. 2.4.THE TANK SIZE, FITTINGS, AND ACCESSORIES, SHALL BE AS SHOWN ON THE DRAWINGS. 2.5.TANK SHALL BE MANUFACTURED WITH A LAMINATE CONSISTING OF RESIN AND GLASS FIBER REINFORCEMENT ONLY. NO SAND/SILICA FILLERS OR RESIN EXTENDERS SHALL BE USED. 2.6.TANK SHALL BE VENTED TO ATMOSPHERIC PRESSURE. 2.7.TANK SHALL BE CAPABLE OF HANDLING LIQUIDS WITH SPECIFIC GRAVITY UP TO 1.1. 2.8.TANK SHALL BE COMPATIBLE WITH LIQUIDS IDENTIFIED IN THE MANUFACTURER'S STANDARD LIMITED WARRANTY. 3.TANK, COVERS, CONNECTIONS AND PIPING SHALL BE DESIGNED AND CONSTRUCTED SO AS TO WITHSTAND AN ANTICIPATED MINIMUM HS-20 LOADING. 4.TIGHT TANK SHALL BE MANUFACTURED IN ACCORDANCE WITH A QUALITY CONTROL/QUALITY ASSURANCE PROGRAM. THE PROGRAM FOR CONCRETE TANKS SHALL BE IN CONFORMITY WITH ASTM STANDARD C 1227-96OR AN ASTM EQUIVALENT STANDARD. CONCRETE TANKS SHALL BE EMBOSSED WITH A SEAL STATING THAT THIS ASTM STANDARD HAS BEEN MET. 5.TIGHT TANK SHALL BE EQUIPPED WITH A CONTINUOUS LEAK DETECTION SYSTEM, SUCH AS TRUCHECK BY XERXES OR SIMILAR. THE LEAK SYSTEM SHALL BE HARDWIRED WITH THE SEPTIC ALARM SYSTEMS. TIGHT TANK SHALL BE VACUUM TESTED FOR WATER TIGHTNESS AFTER INSTALLATION IN ACCORDANCE WITH ASTM C 1227. ALL TANKS MUST PASS TESTING PRIOR TO USE. TIGHT TANK SYSTEM GENERAL NOTES 1.THE SANITARY SEWAGE SYSTEM SHOWN SHALL BE INSTALLED IN ACCORDANCE WITH THE COMMONWEALTH OF MASSACHUSETTS STATE ENVIRONMENTAL CODE 310 CMR 15.00 (TITLE V) AND ANY LOCAL BOARD OF HEALTH REGULATIONS. 2.ANY MODIFICATION TO THE WORK SHALL BE APPROVED IN WRITING BY THE ENGINEER AND THE LOCAL BOARD OF HEALTH PRIOR TO PERFORMANCE. 3. THE TIGHT TANK SHALL BE H-20 DESIGN REINFORCED CONCRETE PRECAST MANUFACTURED BY OLDCASTLE PRECAST OR APPROVED EQUAL. 4.WHEREVER SEWER LINES CROSS WATER SUPPLY LINES, BOTH PIPES SHALL BE CONSTRUCTED OF CLASS 150 (MIN.) PRESSURE PIPE TO 10' ON EITHER SIDE OF CROSSING. PIPES SHALL ALSO BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. 5.NOTIFY THE LOCAL BOARD OF HEALTH AGENT AND ENGINEER AT THE TIME OF EXCAVATION, PRIOR TO INSTALLATION. 6.NOTIFY LOCAL BOARD OF HEALTH AGENT AND ENGINEER WHEN SYSTEM IS COMPLETED AND READY FOR INSPECTION. 7.SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE PROVIDED TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE START OF INSTALLATION: ·ALL UNDERGROUND STRUCTURES (TANKS, STEPS) ·FRAMES AND COVERS ·PIPES, FITTINGS ·WATERPROOFING & PIPE GASKETS PVC SEWER PIPE TRENCH SECTION N.T.S. AREAS PAVED AREAS 6" LOAM & SEED LANDSCAPED FINISH GRADE LC OF PIPE 12"12" VARIES 12" (6" MIN.) 1/2 O.D. PIPE O.D. PAVEMENT STRUCTURE PATCH TO MATCH EXISTING DEPTH & MATERIALS AS REQUIRED BY LOCAL & STATE REQUIREMENTS. LIMITS OF FULL DEPTH SAW-CUT PAYMENT LINE EXCAVATION TRENCH ROCK 3/4" CRUSHED STONE 12" NOTES: METALLIC IDENTIFICATION TAPE 1. METALIZED 2" WIDE DETECTABLE IDENTIFICATION TAPE SHALL BE INSTALLED OVER SEWER LINES 12" BELOW FINISH GRADE. PIPE BEDDED IN COMPACTED CRUSHED STONE MEETING MASSDOT STANDARD SPECIFICATION M2.01.4 OR M2.01.5 PLACED AGAINST UNDISTURBED SIDES AND BOTTOM OF TRENCH FOR FULL LENGTH OF PIPE STRUCTURE TESTING NOTES: CLEANOUT FRAME & COVER (MIN. 6" DIAMETER) SET CASTING ASSEMBLY IN CONCRETE COLLAR, OR PER MANF. END OF LINE CLEANOUT 6" CI RISER PIPE 3 4" CRUSHED STONE NOTES: 1.CLEANOUT FRAME AND COVER SHALL BE ONE OF THE FOLLOWING: A.PRODUCT NUMBER 00157324C01 AS MANUFACTURED BY EAST JORDAN IRON WORKS, FABRICATED FROM GRAY IRON AND CONFORMING TO ASTM A48 CLASS 35B; OR APPROVED EQUAL. SEWER CLEANOUT TYPICAL DETAIL One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY CLEAN COMPACTABLE BACKFILL N.T.S. CONCRETE ENCASEMENT PROPOSED SEWER 6" 6" 3,000 PSI, 28-DAY STRENGTH CONCRETE UNDISTURBED EXISTING MATERIAL PLACE SUITABLE FILL MATERIAL ABOVE CONCRETE CRADLE SHALL EXTEND ON BOTH SIDES OF PIPE TO UNDISTURBED MATERIAL 12/23/2024 12/23/2024 12/23/2024 WF C-107WF C - 1 0 8 WF C-109 WF C-110 WF C-111 WF C - 1 1 3 WF C-1START WF C-3 WF C-2 WF C-4 WF C--5 WF C-6 WF C-7 WF C-8 WF C-9 WF C-102 WF C-103 WF C-104 WF C-105 WF C-106 EXISTING WATER STORAGE TANK EXISTING STRAIGHTWAY FACILITY BUILDING PUMPSTATIONWF C-115 WF C-116 WF C-117 WF C-118 20" DEC 22" DEC 12" DEC 6" DEC 10" DEC 8" EVR10" EVR12" EVR 14" EVR 22" EVR 43.9'38.6'27.5'FFE = ± 23.2'FFE = ± 23.9' FFE = ± 32.7' CONCRETE BOUND FOUND-HELD POSITION S T R A I G H T W A Y (P U B L I C W A Y - 4 0 ' W I D E )ΔΔ400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT 400' WELLHEAD PROTECTION LIMIT IRON ROD SET EXISTING BOOSTER PUMP STATION 12.6' CANDL E WI C K LANE APPRO X. R O W 10' SIDE YARD SETBACK20' FRONT YARD SETBACK 10' SIDE YAR D S E T B A C K WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 BARNSTABLE TOWER 1 TURNING DIAGRAM Tower 1 CHEMICAL TRACTOR TRAILER TRUCK TURNING ANALYSIS WB-67 - Interstate Semi-Trailer ESTIMATED FUTURE WELL REPLACEMENT LOCATION 400' ESTIMATED FUTURE WELLHEAD REPLACEMENT PROTECTION LIMIT C1-153 14 STRAIGHTWAY TURNING DIAGRAM NOT FOR CONSTRUCTION SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' N MPS MD/MPS TB/GAA GAA - One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY 12/23/2024 12/23/2024 12/23/2024 8910111213141517 18 14 13 12111010109811121314 15 14131618 20201 9 18 1 7 1 6 15 14 14 1 4 13121110987 7 89 10 11 11 1 1 1091011 12 13 14 13 12 11 1125242322 2120191817 16 16 1522 21 201918 17 WF B-14 STOP WF B-13 WF B-1 2 WF B-11 WF B-10WF B-9 WF B-8 WF B-7 WF B-6 WF B-5 WF BF2 - 1 S T A R T L E 1 1 2 9 2 3 WF B-1 START LE112923WF B-2 WF A-9 S T O P B F 1 - 9 E N D WF A-8 WF A-7 WF A-6WF A-5WF A-4WF A-3WF A-2WF A-1 START LE112923WF B-3 WF B-4 WF B-119 WF B-118 WF B-117 WF B-116 WF B-115 WF B-112 WF B-111WF B-110 WF B-109 WF B-108 WF B-107 WF B-106 WF B-105 WF B-104 WF B-103 WF B-102 WF B-101 WF B-100 START LE112923 BITUMINOUS PAVEMENT 27.0'39. 3 ' SI M M O N S P O N D (LO C A T I O N M A S S G I S ) HALLS CREEKWF BF2-2 WF BF2-3WF BF2-4 W F B F 2 - 5 WF BF2-6 WF BF2-7WF BF2.8 WF BF2-9 WF 2-10 WF 2-11 WF BF2-12WF BF2-13 WF BF2-14END WF BF1-4 WF BF1-2 WF BF1-1 START LE112923 WF BF1-5 WF BF1-6 WF BF1-7 WF BF1-8 WF B-113 NE WF B-114 NE SIMMONS POND WELL STATION BANK FLAGS BF1-9 DELINEATED BY LUCAS ENVIRONMENTAL 11/29/2023 COB B L E S T O N E STRI P TREE LI N E (TYP. ) 20.0'16.0'UNDERGROUND ELECTRIC LINE LOCATION APPROXIMATE TREELINE (TYP.) HY A N N I S P O R T W E L L ST A T I O N FFE = ± 1 4 . 7 ' FFE = ± 9.7' CB INV = ± 6 . 8 ' CB INV = ± 8 . 0 ' CONCRETE HEADWALL CULVERT SMI T H S T R E E T (PU B L I C W A Y - 4 0 ' W I D E ) FLOW 400' EXISTING WELLHEAD PROTECTION LIMIT 400' EXISTING WELLHEAD PROTECTION LIMIT TBM CONCRETE BOUND 4 CONCRETE BOUND WITH DRILL HOLE FOUND ELEV: 15.17' CONCRETE BOUND WITH DRILL HOLE FOUND SET IRON ROD WITH CAP CHAIN LINK FEN C E ( T Y P ) BIT U M I N O U S PA V E M E N T FEMA FLOOD ZONE XBOUNDARYB-9 B-1 0 TBM - SOUTH-EASTERLY HYDRANT FLANGE BOLT ELEV. = 17.77' TBM - SOUTH-EASTERLY HYDRANT FLANGE BOLT ELEV. = 13.61' SP- 0 3 SP- 0 3 A - O W HP- 0 2 B HP- 0 2 B - O W EXTERNAL GENERATOR 8" DI WATER MAIN LOCATION APPROXIMATE FROM RECORD PLANS 8" C I UNDERGROUND ELECTRIC LINE UP # 3 4 - 3 A 1" WATER SAMPLE PIPE GRAVEL PARKING AREA EXISTING 10" DI WATER MAIN PLANTER AREA W/STONE WALL PERIMETER EXISTING 10" AC WATER MAIN EXISTING 10" AC WATER MAIN HYANNISPORT STATION UNDERGROUND ELECTRICAL SERVICE SIMMONS POND STATION UNDERGROUND ELECTRICAL SERVICE EXISTING PAVED DRIVEWAY EXISTING MONITORING WELL EXISTING ACCESS GATE EDGE OF BORDERING VEGETATED WETLAND 20' F R O N T Y A R D S E T B A C K10' SIDE YARD SETBACK10' SIDE YARD SETBACKWETLAND FLAGGED BY THOMAS E. LIDDY, PWS/CWS ON 11/29/23 WETL A N D FL A G G E D B Y THOM A S E. LI D D Y, PW S/ C W S O N 11/29/23 TBM CONCRETE BOUND 5 CONCRETE BOUND W/ DRILLHOLE FOUND -HELD FOR ALIGNMENT ELEV: 17.12' C2-111 15 HYANNISPORT - SIMMONS POND EXISTING CONDITIONS SCALE IN FEET 0 30 60 90 SCALE: 1" = 30' NOT FOR CONSTRUCTION N MPS MD/MPS TB/GAA GAA - One Beacon Street, Suite 8100 Boston, MA 02108 Phone: 617-497-7800 www.kleinfelder.com REV DESCRIPTION DSN DWN CHK APP DATE REVISIONS WATER SUPPLY DIVISION 47 OLD YARMOUTH ROAD HYANNIS, MA 02601 24003062.001APROJECT NO. ISSUE DATE CURRENT REVISION DESIGNED BY DRAWN BY CHECKED BY APPROVED BY 12/23/2024PLOTTED:NOI SUBMITTAL SHEET TOWN OF BARNSTABLE DPW of 31 ORIGINAL DRAWING SIZE IS 22 x 34 SCALE VERIFICATION THIS BAR IS 1 INCH IN LENGTH ON ORIGINAL DRAWING IF IT'S NOT 1 INCH ON THIS SHEET ADJUST YOUR SCALES ACCORDINGLY 0 1" WATER TREATMENT FACILITY STRAIGHTWAY 12/23/2024 12/23/2024 12/23/2024