HomeMy WebLinkAboutCOA 90 Pine StreetINSTALLATION OF NEW ROOF MOUNTED PV SOLAR / ENERGY STORAGE SYSTEM 90 PINE STREET WEST BARNSTABLE, MA 02668 41.6935, -70.3773 PINE STREET P1 ISSUED TO TOWNSHIP FOR PERMIT 1/23/2025 NO.DESCRIPTION DATE DEVINE, BRYCSON (SOLAR STORAGE) TRINITY ACCT #: 2024-10-1196187 90 PINE STREET WEST BARNSTABLE, MA 02668 41.6935, -70.3773 PROPOSED PV SOLAR / ENERGY STORAGE SYSTEM DRAWING DATE:1/23/2025 DRAWN BY:FJ REVISED BY: DC SYSTEM SIZE:9.84kW AC SYSTEM SIZE:11.5kW MODULE COUNT:24 MODULES USED:HANWHA 410 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 410 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:74001391900 UTILITY METER #:2287225 DEAL TYPE:SUNNOVA P1 (9.84kW SITE EXPORT) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 9 PITCH: 18 ORIENTATION: 84 ROOF 2 MODULES: 10 PITCH: 18 ORIENTATION: 264 ROOF 3 MODULES: 5 PITCH: 51 ORIENTATION: 264 ROOF 4 MODULES: 0 PITCH: 51° ORIENTATION: 84° ROOF 5 MODULES: 0 PITCH: 16° ORIENTATION: 84° ROOF 6 MODULES: 0 PITCH: 16° ORIENTATION: 264° DC AC G epM DC AC ***NOTE: 2021 NFPA 1 - 11.12.3.2.4.1 PLAN VIEW TOTAL ROOF AREA: 1463.3 FT² PHOTOVOLTAIC ARRAY TOTAL AREA: 455.5 FT² ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 31.1%NS27090 1 3 5 22545315DC AC G epM DC AC 41.6935, -70.3773 24 HANWHA 410 (Q.PEAK DUO BLK ML-G10+ 410) 1 TESLA (BACKUP GATEWAY 2) 1 TESLA 11.5kW (POWERWALL 3) 1 TESLA AC COUPLED (POWERWALL 3) INSIDE OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE) P1 ISSUED TO TOWNSHIP FOR PERMIT 1/23/2025 NO.DESCRIPTION DATE DEVINE, BRYCSON (SOLAR STORAGE) TRINITY ACCT #: 2024-10-1196187 90 PINE STREET WEST BARNSTABLE, MA 02668 41.6935, -70.3773 PROPOSED PV SOLAR / ENERGY STORAGE SYSTEM DRAWING DATE:1/23/2025 DRAWN BY:FJ REVISED BY: DC SYSTEM SIZE:9.84kW AC SYSTEM SIZE:11.5kW MODULE COUNT:24 MODULES USED:HANWHA 410 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 410 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:74001391900 UTILITY METER #:2287225 DEAL TYPE:SUNNOVA P1 (9.84kW SITE EXPORT) NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC SD 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.comG CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.8(B)(1)]: (11.20*1.56)1 = 17.47A AWG #10, DERATED AMPACITY AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 8 CCC: 0.70 (40*.96)0.70 = 26.88A 26.88A >_ 17.47A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 48.00A*1.25 = 60.00A AWG #6, DERATED AMPACITY AMBIENT TEMP: 30°C, TEMP DERATING: 1.0 RACEWAY DERATING <_ 3 CCC: N/A 75A*1.0 = 75A 75A >_ 60.00A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL INVERTER CURRENT: 48.00A 48.00A*1.25 = 60.00A --> 60A OVERCURRENT PROTECTION IS VALID ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2023 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP = 33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.) DISCONNECTS FED BY SUPPLY-SIDE SOURCE CONDUCTORS SHALL BE BONDED AND CONNECTED TO GROUNDING SYSTEM IN ACCORDANCE WITH NEC 250.24 12.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 13.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(B)(2) 14.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 15.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING BACKUP GATEWAY TESLA (BACKUP GATEWAY 2) OCPD 100A AIC MAX 10kA Vnom 240 A 1 - #2 ALU. SEU CABLE B 1 - #2 ALU. SER CABLE C 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#10 THWN-2 GROUND D 1 1/4'' CONDUIT W/ 4-#6 THWN-2, 2-#6 THWN-2, 2-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 8-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #8 BARE COPPER BOND TO ARRAY G LOW VOLTAGE COMMUNICATION (STANDARD RS485) NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS PV MODULE SPECIFICATIONS HANWHA 410 (Q.PEAK DUO BLK ML-G10+ 410) Imp 10.89 Vmp 37.64 Voc 45.37 Isc 11.2 EXISTING MAIN BREAKER LOAD CENTERNEUTRAL240V1Ø2p100AMAIN100A MAIN BREAKER 100A BUSBAR NEUTRAL NEW BACKUP GATEWAY 1Ø CT METERS 2p60A B 2p60A MEXISTING 1Ø 120/240V UTILITY METER A 2p100A MAIN 240V -+L1L2NSOLAR MODULES MOUNTED TO ROOF ON 3 ARRAYS 24 - 410W MODULES W/ 1 TESLA MCI-2 PER 3 MODULES 14 ADC MAX PER STRING 1 STRING OF 9 MODULES IN SERIES - 463.41 Vmax (R1) 1 STRING OF 5 MODULES IN SERIES - 257.45 Vmax (R2) 1 STRING OF 5 MODULES IN SERIES - 257.45 Vmax (R2) 1 STRING OF 5 MODULES IN SERIES - 257.45 Vmax (R3) *4 STRINGS TO BE TERMINATED INSIDE INVERTER 1 INVERTER / BATTERY #1 -+L1L2NCC G F 8"x8" JUNCTION BOX INVERTER / BATTERY #2 E D G INVERTER / BATTERY #2 DC AC Imp -Pout 11500 Vmp -Imax 48 Voc -OCPDmin 60 Isc -Vnom 240 ENERGY 13.5kWh INVERTER / BATTERY #1 DC AC Imp 43.56 Pout 11500 Vmp 338.76 Imax 48 Voc 463.41 OCPDmin 60 Isc 56 Vnom 240 ENERGY 13.5kWh POWERWALL 3 UNIT(S) TO BE SET TO: DEFAULT (SOLAR ONLY) - THE BATTERY IS COMMANDED TO NOT EXPORT BEYOND THE SITE METER. THE EXPORT AT THE SITE METER WILL BE LIMITED TO THE AMOUNT MEASURED BY THE SOLAR METER. BATTERIES SHALL NOT DISCHARGE TO THE GRID. PV SYSTEM / INVERTER SITE EXPORT SHALL NOT EXCEED DC SYSTEM RATING. ***NOTE: PV SHALL NOT BE CONNECTED TO UNIT #2 ***NOTE: P1 ISSUED TO TOWNSHIP FOR PERMIT 1/23/2025 NO.DESCRIPTION DATE DEVINE, BRYCSON (SOLAR STORAGE) TRINITY ACCT #: 2024-10-1196187 90 PINE STREET WEST BARNSTABLE, MA 02668 41.6935, -70.3773 PROPOSED PV SOLAR / ENERGY STORAGE SYSTEM DRAWING DATE:1/23/2025 DRAWN BY:FJ REVISED BY: DC SYSTEM SIZE:9.84kW AC SYSTEM SIZE:11.5kW MODULE COUNT:24 MODULES USED:HANWHA 410 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 410 UTILITY COMPANY:EVERSOURCE UTILITY ACCT #:74001391900 UTILITY METER #:2287225 DEAL TYPE:SUNNOVA P1 (9.84kW SITE EXPORT) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com JOB NAME:DEVINE, BRYCSON (SOLAR STORAGE) ADDRESS:90 Pine Street West barnstable, MA 02668 41.6935, -70.3773 65.96 ESTIMATED PERSONNEL HOURS 2.75 DAYS 2.06 DAYS 1.37 DAYS •24 HANWHA 410's (9.84KW)(CREW OF 3)(CREW OF 4)(CREW OF 6) •3 SEPARATE ARRAYS •17' PEAK TO GROUND •5 PORTRAIT & 19 LANDSCAPED •1 INVERTER(S) INSTALLED OUTSIDE •NO TRENCH ESTIMATED SENT TO JOB USED □HANWHA 410 (Q.PEAK DUO BLK ML-G10+ 410)24 ______ □TESLA MCI-2 9 ______ □TESLA (BACKUP GATEWAY 2)1 ______ □TESLA (POWERWALL 3)2 ______ □60A OUTDOOR NON-FUSED DISCONNECT 1 ______ □SOLADECK BOX(ES) & HAYCO CONNECTOR(S)3 ______ □PV LEAD WIRE 200'______ □ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 23 ______ □ECOFASTEN 2012013 CF RAIL SPLICE 9 ______ □ECOFASTEN 2099017 CF END CLAMP 32MM BLK 36 ______ □ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 30 ______ □ECOFASTEN 4011011 MODULE JUMPER 6 ______ □GROUNDING LUG(S)3 ______ □ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 90 ______ □ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8X10 90 ______ □ECOFASTEN 3016018 SCREW #14X3 W/BW 90 ______ □ECOFASTEN 2012019 CF MLPE MOUNT 24 ______ □ECOFASTEN 2012020 CF WIRE MGMT CLIP 24 ______ □ECOFASTEN 2012024 CF END CAP 36 ______ □2p60A BREAKER 2 ______ MATERIAL LIST (FOR INTERNAL USE ONLY) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com INSTALLATION OF NEW ROOF MOUNTED PV SOLAR / ENERGY STORAGE SYSTEM 90 PINE STREET DEVINE, BRYCSON (SOLAR STORAGE) 90 PINE STREET WEST BARNSTABLE, MA 02668 41.6935, -70.3773 APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com WEST BARNSTABLE, MA 02668 152003001 WEST BARNSTABLE DEER CLUB INC PO BOX 522 Property ID: 19 CUTLER STREET LEOMINSTER, MA 01453 153001 MORALES, CARLOS E & GLORIA P TRS MORALES FAMILY REVOCABLE TRUST Property ID: HYANNIS, MA 02601 153002 BARNSTABLE, TOWN OF (CEM) 367 MAIN STREET Property ID: WEST BARNSTABLE, MA 02668 153024 DEVINE, BRYCSON J & CHRISTINA M 90 PINE STREET Property ID: WEST BARNSTABLE, MA 02668 153025 DOMINATTO, CELIO A & NANCY B 134 PINE STREET Property ID: 226 OLD LANCASTER ROAD SUDBURY, MA 01776-2212 153029 MCCORMICK, DAVID W JR, PR ESTATE OF JANE F MCCORMICK Property ID: WEST BARNSTABLE, MA 02668 153031001 DOLGOFF, ARTHUR L & SHIRLEY A 19 MCCORMICK DRIVE Property ID: