Loading...
HomeMy WebLinkAboutAP-2025-013 - Civil Site PlansMINIMUM LOT AREA (SF)90,000 SF OR 1,500 SF/UNIT 652,497 SF OR 2,039 SF/UNIT MINIMUM LOT FRONTAGE (FT)N/A 56.1 FT MINIMUM FRONT YARD SETBACK (FT)60 FT 106.5 FT MINIMUM SIDE AND REAR YARD SETBACK (FT)30 FT 31 FT MAXIMUM BUILDING HEIGHT (FT)1 55 FT Less than 55 FT MAXIMUM FLOOR AREA RATIO 0.75 0.569 MAXIMUM LOT COVERAGE 25%16.2% MAXIMUM IMPERVIOUS COVERAGE 50%47.5% PERIMETER GREEN SPACE 20 FT 30 FT MIN. ZONING SUMMARY Mix-Use Sub Zone within the Medical Services Overlay District Requirement PROPOSED 1 Multifamily structures on a lot not less than 10 acres, the maximum building height shall be 55 feet measured to the highest point on the roof (not including antennas or similar roof structures). 1.3 SPACE PER UNIT =416 +1 GUEST SPACE PER 10 UNITS =32 SURFACE PARKING =430 GARAGE PARKING =46 15 SPACES (INCLUDING 2 GARAGE) 448 SPACES 476 SPACES TOTAL PARKING SUMMARY PARKING REQUIREMENT PARKING PROVIDED ACCESSIBLE PARKING REQUIRED 9 SPACES (2 VAN) ACCESSIBLE PARKING PROVIDED ALL SURFACE SPACES ARE VAN ACCESSIBLE xxxxxxxxxxxxxxxxxx xx xx S D S D S D S D SDSD505254W ILKEN SL A N E 55 56 58 58 56 5750565452 51525354 55 56 464850585555575 75655 57 57.4SD SD5 0 EXISTINGRESIDENTIALBUILDING4STORIESD R A IN A G E E A S E M E N T UTI LI TYEASEMENT515250 50525150 TW=53.00 BW=52.00 TW=55.00 BW=50.5050SDDCB #22 R=49.70 I=46.20 RETAINING WALL (DESIGN BY OTHERS) LOT 2B 90,016 S.F. 2.07 ACRES (PROPOSED)PROPOSEDLOTLINEP R O P O S E D 1 5 'W I D E S E W E R E A S E M E N T 0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:11:55PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-13-17GRADINGANDDRAINAGEPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-13ConceptualSitePlansHanoverHyannisIIGradingandDrainagePlan100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEE SHEET C-15 UEUEUEUExxxxxxxxxxxxxxxxxx xx xx U E U E W W UEUEUEUEUEUEU E U E U E U E U E U E U E U E WWWWWWWWWWW W W W WWWS D S D S D S D SDSDW ILKEN SL A N E SDSDWWWWEXISTINGRESIDENTIALBUILDING4STORIESD R A IN A G E E A S E M E N T UTI LI TYEASEMENTLOT 2B 90,016 S.F. 2.07 ACRES (PROPOSED)PROPOSEDLOTLINEP R O P O S E D 1 5 'W I D E S E W E R E A S E M E N TSDRETAININGWALL (DESIGN BY OTHERS)GGGGGGCONNECT GAS PER NATIONAL GRID WWWWWWFMFMFMFMFMF M F M F M 4 "P V C S D R 2 1 F O R C E M A IN12"CLDIE/T/DE/T/DE/T/DE/T/DE/T/DWWWWWW12"CLDIGGGGGGCONNECT GAS PER NATIONAL GRID WWWWWWFMFMFMFMFMF M F M F M 4 "P V C S D R 2 1 F O R C E M A IN12"CLDIE/T/DE/T/DE/T/DE/T/DE/T/DWWWWWW12"CLDI0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/16/20252:13:11PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-18-23UTILITYPLANS.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-18ConceptualSitePlansHanoverHyannisIIUtilityPlan100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEE SHEET C-20 SEESHEETC-23 UEUEUEUExxxxxxxxxxxxxxxxxx xx xx U E U E UEUEUEUEUEUEU E U E U E U E U E U E U E U E S D S D S D S D SDSD505254W ILKEN SL A N E 55 56 58 58 56 5750565452 51525354 55 56 4648505856555557575655 57 57.4SD SD5 0 EXISTINGRESIDENTIALBUILDING4STORIESD R A IN A G E E A S E M E N T UTI LI TYEASEMENTLOT 2B 90,016 S.F. 2.07 ACRES (PROPOSED)PROPOSEDLOTLINE515250 50525150 TW=53.00 BW=52.00 TW=55.00 BW=50.5050SD RETAINING WALL (DESIGN BY OTHERS) x x x x x x x x x x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxCATCH BASIN INSERT (TYP) LIMIT OF WORK / COMPOST FILTER TUBE (TYP) LIMIT OF WORK / CONSTRUCTION FENCE (TYP) STABILIZED CONSTRUCTION EXIT 515250 50525150 TW=53.00 BW=52.00 TW=55.00 BW=50.5050SD RETAINING WALL (DESIGN BY OTHERS) 0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:28:22PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-24-29EROSION&SEDIMENTCONTROLPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-24ConceptualSitePlansHanoverHyannisIIErosion&SedimentControlPlan100NickersonRoadMarlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEE SHEET C-26 SEESHEETC-28A xx xx xx xxxxxxxx50 5 0 4 4 4 2 4 244DRAINAGEEASEMENTRESIDENTIAL BUILDING 2 4 STORIES FFE=51.50 RESIDENTIAL BUILDING 3 4 STORIES FFE=51.50 RESIDENTIAL BUILDING 1 4 STORIES FFE=51.50 POOL GARAGE B FFE=50.20GARAGEDFFE=50.70BIKE STORAGE LOT 2A 652,497 S.F. 14.98 ACRES (PROPOSED) PROPOSED LOT LINE GARAGE A FFE=51.90GARAGECFFE=51.10EMBAYMENT LINE (TYP.) EMBAYMENT LINE (TYP.) 51 5 0 50 5051 50.40 50.30 49.50 50 49 48 48 50 49 H.P.50.30 H.P. 50.40 H.P. 50.30 H.P. 50.30 H.P.H.P.51505150 505 0 5 0 5 1 5049484746444550494847464550494847515149.5050.505 050 51 50 50.10 49.90 49.8049.85 49.7550.80 50.80 49.90 50.10 50.20 50.30 50.4550.65 49.8049.90 50.6050.65 49.9049.80 50.20 50.10 50.00 50.10 50.10 50.60 50.50 50.30 50.65 50.15 50.20 49.90 50.30 50.40 50.1050.30 49.9049.80 50.6050.70 49.9049.90 SDSDSD SD SD SD SD SD SDSDSDSDSDSDSDSDSD 48 49 50 CATCH BASIN INSERT (TYP) LIMIT OF WORK / COMPOST FILTER TUBE (TYP) 51 5 0 50 5051 50.40 50.30 49.50 50 49 48 48 50 49 H.P.50.30 H.P. 50.40 H.P. 50.30 H.P. 50.30 H.P.H.P.51505150 505 0 5 0 5 1 5049484746444550494847464550494847515149.5050.505 050 51 50 50.10 49.90 49.8049.85 49.7550.80 50.80 49.90 50.10 50.20 50.30 50.4550.65 49.8049.90 50.6050.65 49.9049.80 50.20 50.10 50.00 50.10 50.10 50.60 50.50 50.30 50.65 50.15 50.20 49.90 50.30 50.40 50.1050.30 49.9049.80 50.6050.70 49.9049.90 SDSDSD SD SD SD SD SD SDSDSDSDSDSDSDSDSD 48 49 50 LIMIT OF WORK / COMPOST FILTER TUBE ADJUST AS NEEDED FOR NEW FIRE ACCESS 0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:29:41PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-24-29EROSION&SEDIMENTCONTROLPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-25ConceptualSitePlansHanoverHyannisIIErosion&SedimentControlPlan100NickersonRoadMarlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEESHEETC-26SEE SHEET C-27 60 59586057586054575659575 8 5 8 585657565656565656555456575558565758586158 SDEXISTING MAINTENANCE BLDG. 50 5 0 5 0 4 4 4 2 4 2 EXISTINGRESIDENTIALBUILDING4STORIESEXISTINGGARAGERESIDENTIAL BUILDING 2 4 STORIES FFE=51.50 RESIDENTIAL BUILDING 1 4 STORIES FFE=51.50 LEASING /CLUB FFE=52.50 POOL LOT 2A 652,497 S.F. 14.98 ACRES (PROPOSED) GEN PROPOSED LOT LINE PROPOSEDACCESSEASEMENT50.0' GARAGE A FFE=51.90 EMBAYMENT LINE (TYP.) EMBAYMENT LINE (TYP.) 51 50 5051 50.40 50.30 49.50 53.80 50 48 50 6052 5 2 52 51 RG1 RG2 53 52525 1 51 505152TW=54.00 BW=53.004949484850515151515050 505149 48 49 52 51 50 H.P. 51.30 H.P.H.P.51515052 5 2 49495051525354545551.30 H.P.51SDSD SDSDSDSD RETAINING WALL (DESIGN BY OTHERS) 5 0 51 50 50.10 49.90 515049.90 50.5051.5050.4050.3049.8049.85 49.75 50.6050.65 49.9049.80 50.4050.10 51.30 50.6050.70 49.9049.90 50.9050.80 51.60 51.20 51.60 51.60 51.30 50.10 50.10 49.90 49.90 49.90 49.90 5049.90 49.90 49.90SDSD SD SD SD SD SD 57565 5 5 453 545352.20 52.50 TW=56.00 BW=55.00 TW=56.00 BW=55.00 TW=56.00 BW=54.00 52.10 52.60 52.40 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxCATCH BASIN INSERT (TYP) LIMIT OF WORK / COMPOST FILTER TUBE (TYP) LIMIT OF WORK / CONSTRUCTION FENCE (TYP) 51 50 5051 50.40 50.30 49.50 53.80 50 48 50 6052 5 2 52 51 RG1 RG2 53 52525 1 51 505152TW=54.00 BW=53.004949484850515151515050 505149 48 49 52 51 50 H.P. 51.30 H.P.H.P.51515052 5 2 49495051525354545551.30 H.P.51SDSD SDSDSDSD RETAINING WALL (DESIGN BY OTHERS) 5 0 51 50 50.10 49.90 515049.90 50.5051.5050.4050.3049.8049.85 49.75 50.6050.65 49.9049.80 50.4050.10 51.30 50.6050.70 49.9049.90 50.9050.80 51.60 51.20 51.60 51.60 51.30 50.10 50.10 49.90 49.90 49.90 49.90 5049.90 49.90 49.90SDSD SD SD SD SD SD 57565 5 5 453 545352.20 52.50 TW=56.00 BW=55.00 TW=56.00 BW=55.00 TW=56.00 BW=54.00 52.10 52.60 52.40 LIMIT OF WORK / CONSTRUCTION FENCE ADJUST AS NEEDED FOR NEW WALK 0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:30:30PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-24-29EROSION&SEDIMENTCONTROLPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-26ConceptualSitePlansHanoverHyannisIIErosion&SedimentControlPlan100NickersonRoadMarlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEE SHEET C-24 SEE SHEET C-28 SEESHEETC-25 7 0 70 60 60 50 50 DRAINAGEEASEMENTR E S ID E N T IA L B U IL D IN G 4 4 S T O R IE S F F E =5 3 .0 0 F GAR AGE E FFE=50.20 GARAGE F FFE=50.50 G A R A G E G F F E =5 2 .4 0 GARAGEDFFE=50.70MAINTENANCEB I K E S T O R A G E 5 2 5 0 5050.30 5151.80 52.30 5252.40 5 2 51504847RG3 51.40 5150.30 H.P. 50.30 H.P.H.P. 52.30 H.P.525252.30 H.P. H.P. H.P. 52.30H.P. 52 5252 52505 05050 51 51 51 5 2 51 51 5 2 52 5150525246 5049484746H.P. 52 515 1 5 2 5 2 5 2 5 3 5 4 5 5 5 6 5 7 5 8 49525 3 5 2 5 2 5 9 6 0 6 2 6 1 6 0 SD SDSDSDSD S D S D S D S D 505250.40 50.40 50.1050.30 49.9049.80 50.6050.70 49.9049.90 50.70 49.7049.70 50.70 50.10 50.20 52.20 52.30 52.20 52.30 52.20 51.20 51.20 51.80 52.05 51.90 52 52.20 52.30 52.10 52.30 52.20 52.10 50.90 50.90 52.70 52.70 51.90 52.40 50.90 51.80 51.60 52.50 52.30 H.P. 52.70 51.60 51.80 50.80 SDSDxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxCATCH BASIN INSERT (TYP) LIMIT OF WORK / COMPOST FILTER TUBE (TYP) LIMIT OF WORK / CONSTRUCTION FENCE (TYP) 5 2 5 0 5050.30 5151.80 52.30 5252.40 5 2 51504847RG3 51.40 5150.30 H.P. 50.30 H.P.H.P. 52.30 H.P.525252.30 H.P. H.P. H.P. 52.30H.P. 52 5252 52505 05050 51 51 51 5 2 51 51 5 2 52 5150525246 5049484746H.P. 52 515 1 5 2 5 2 5 2 5 3 5 4 5 5 5 6 5 7 5 8 49525 3 5 2 5 2 5 9 6 0 6 2 6 1 6 0 SD SDSDSDSD S D S D S D S D 505250.40 50.40 50.1050.30 49.9049.80 50.6050.70 49.9049.90 50.70 49.7049.70 50.70 50.10 50.20 52.20 52.30 52.20 52.30 52.20 51.20 51.20 51.80 52.05 51.90 52 52.20 52.30 52.10 52.30 52.20 52.10 50.90 50.90 52.70 52.70 51.90 52.40 50.90 51.80 51.60 52.50 52.30 H.P. 52.70 51.60 51.80 50.80 SDSD0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:31:11PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-24-29EROSION&SEDIMENTCONTROLPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-27ConceptualSitePlansHanoverHyannisIIErosion&SedimentControlPlan100NickersonRoadMarlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEE SHEET C-25 SEESHEETC-28 60708 0 906062 64 66 68 70 80 78767472 608 0 7061EXISTING MAINTENANCE BLDG.7070707 0 60 60 50 6 0 80VARIABLEWIDTHSLOPEEASEMENTVARI ABLEWI DTHSLOPEEASEMENTR E S I D E N T I A L B U I L D I N G 5 4 S T O R I E S F F E = 5 3 . 0 0 GARAGE F FFE=50.50 G A R A G E G F F E =5 2 .4 0 G ARAG EHFFE=52.60B I K E S T O R A G E LOT 2C 8,546 S.F. 0.20 ACRES (PROPOSED)PROPOSEDLOTLINE5 2 5 0 5050.30 5151.80 52.30 5 2 526 0 7 0 8 0 605 3 5 2 7 9 5 4 7 8 6 0 5 8 5 2 RG1 51.40 5151.30 H.P.H.P. 51.70 H.P. 5 2 52.30 H.P.525252.30 H.P. H.P. H.P. 52 525151 5051 52.40 51 5 2 51 51 5 2 51504 8 4 8 5 2 5 2 5 2 5 1 4 9 5 0 5 1 5 4 5 5 5 6 5 7 5 8 5 3 5 2 5 9 6 0 6 2 6 1 6 0 5 3 5 4 5 5 5 6 5 7 5 9 S D S D S D S D S D 5050.6050.70 49.9049.90 50.9050.80 51.60 50.70 50.10 50.1050.20 51.30 49.90 51.50 52.30 52.20 52.10 52.20 52.30 52.20 52.30 52.20 51.20 51.20 51.80 52.05 51.90 52 52.20 52.30 51.90 52.40 50.90 51.80 51.60 52.50 52.30 H.P. 52.70 51.60 51.80 50.80 49.90 49.90 5 0 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxCATCH BASIN INSERT (TYP) LIMIT OF WORK / CONSTRUCTION FENCE (TYP) 5 2 5 0 5050.30 5151.80 52.30 5 2 526 0 7 0 8 0 605 3 5 2 7 9 5 4 7 8 6 0 5 8 5 2 RG1 51.40 5151.30 H.P.H.P. 51.70 H.P. 5 2 52.30 H.P.525252.30 H.P. H.P. H.P. 52 525151 5051 52.40 51 5 2 51 51 5 2 51504 8 4 8 5 2 5 2 5 2 5 1 4 9 5 0 5 1 5 4 5 5 5 6 5 7 5 8 5 3 5 2 5 9 6 0 6 2 6 1 6 0 5 3 5 4 5 5 5 6 5 7 5 9 S D S D S D S D S D 5050.6050.70 49.9049.90 50.9050.80 51.60 50.70 50.10 50.1050.20 51.30 49.90 51.50 52.30 52.20 52.10 52.20 52.30 52.20 52.30 52.20 51.20 51.20 51.80 52.05 51.90 52 52.20 52.30 51.90 52.40 50.90 51.80 51.60 52.50 52.30 H.P. 52.70 51.60 51.80 50.80 49.90 49.90 5 0 0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:32:18PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-24-29EROSION&SEDIMENTCONTROLPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-28ConceptualSitePlansHanoverHyannisIIErosion&SedimentControlPlan100NickersonRoadMarlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEE SHEET C-26SEESHEETC-27 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxSDSDS D S D SDSDSDU E UE UE UE UE UE UE UE UE UEUEUEUEUEUEUE UE UE UE UE UE UE UE UE SD SD SD SD W I L K E N S LANE KIDD'SHILLROAD607076606264666 8 5 056 58S34°23'54"E166.43'R=R =3 5 .0 0 'L =5 6 .8 1 'R=630.00'L=549.84' S58°36'06"W 79.74' 5 9 6 0 59605 8 5 8 585 8 58 60605958 58585856 5860 58 57 56 58 5 7 5 7 57 57 59 57.4SDSD SDSD SD SD SD SDEXISTING RESIDENTIALBUILDING 4STORIES EXISTING GARAGE EXISTINGGARAGE LIMIT OF WORK / COMPOST FILTER TUBE (TYP) 0 SCALE: 10'20'40' 1'' = 20'www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:34:22PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-24-29EROSION&SEDIMENTCONTROLPLAN.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-29ConceptualSitePlansHanoverHyannisIIErosion&SedimentControlPlan100NickersonRoadMarlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICTSEESHEETC-24 8" MIN. 2" CLEAR PRECAST CONCRETE DRAIN MANHOLE NOTES: 1. MANHOLE DIAMETER TO BE INCREASED AS REQUIRED TO ACCOMMODATE NUMBER OF PIPES ENTERING OR DISCHARGING FROM MANHOLE. 2. STRUCTURE OPENING VOIDS, AFTER PIPE INSTALLATION, SHALL BE FILLED WITH NON-SHRINK WATERPROOF GROUT. GROUT TO BE COMPLETELY AROUND THE PIPE. GROUT SHALL BE SMOOTH AND PARALLEL TO INTERIOR AND EXTERIOR WALLS. OR AS NOTED ON UTILITY PLANS NOTES: 1. CONCRETE = 4000 PSI MINIMUM, CEMENT PER ASTM C-478 2. MANHOLE TO CONFORM TO LATEST ASTM C-478 SPECIFICATIONS FOR "PRECAST REINFORCED CONCRETE MANHOLE SECTIONS" 3. STEEL REINFORCEMENT TO MEET OR EXCEED H20 LOADING. 4. MANHOLE STEPS - POLYPROPYLENE COATED GRADE 60 REINFORCING BAR, PER ASTM C-478 & OSHA (STD 1-1.9) NOTE: STRUCTURES & CASTINGS SHALL BE RATED FOR H-20 LOADINGEJ FRAME 2114Z AND COVER 2110A1 OR APPROVED EQUAL. COVER SHALL BE FORGED WITH THE WORD DRAIN 9 FEET OR LESS IN DEPTH NOT TO SCALE 8" MIN. CRUSHED STONE (M2.01.4) BRICK LEVELING COURSE AS REQUIRED FOR GRADE ADJUSTMENTS (2 MIN.- 5 MAX.) FRAME TO BE SET IN FULL BED OF MORTAR MIN. 0.12 SQ. IN. STEEL PER VERTICAL FOOT, PLACED ACCORDING TO AASHTO DESIGNATION M-199 MORTAR ALL JOINTS 1 #3 BAR AROUND OPENINGS FOR PIPES 18" DIAMETER AND OVER 1" COVER PIPE OPENINGS TO BE PRECAST IN RISER SECTION NOTE: PAYMENT LIMIT 12" FROM EXTERIOR OF STRUCTURE IN ROCK OUTSIDE OF PIPE +2" CLEARANCE PROVIDE 'V' OPENINGS 18"-24" CONICAL SECTIONS HEIGHT OF RISER SECTIONS MAY VARY FROM 1' TO 4' 5"MIN. 24"±1" DIA. 48"±1" DIA. 30" MAX. PIPE DIA. 8" MIN. PRECAST CONCRETE CATCH BASIN NOT TO SCALE NORMAL WATER LEVEL OUTSIDE PIPE DIAMETER PLUS 2" CLEARANCE EJ FRAME 5523 AND GRATE 5520M5 OR APPROVED EQUAL. 8" MIN. CRUSHED STONE (M2.01.4) MIN. 0.12 SQ. IN. STEEL PER VERTICAL FOOT, PLACED ACCORDING TO AASHTO DESIGNATION M-199 MORTAR ALL JOINTS BRICK LEVELING COURSE AS REQUIRED FOR GRADE ADJUSTMENTS (2 MIN.- 5 MAX.) FRAME TO BE SET IN FULL BED OF MORTAR PROVIDE 'V' OPENINGS 24"±1"x27"±1" OPENING 48"±1" DIA. 5" MIN. HOOD PRECAST CONCRETE BASE UNIT 12" REINFORCED CONC. PIPE (TYP.)1" CLEAR DIAMETEROFOUTLETPIPEX4(4'MIN.)7'-0"(STANDARDDEPTH)18"-24" CONICAL SECTIONS HEIGHT OF RISER SECTIONS MAY VARY FROM 1' TO 4' NOTE: STRUCTURES & CASTINGS SHALL BE RATED FOR H-20 LOADING SEWER MANHOLE NOT TO SCALE NOTE: ALL COVERS SHALL HAVE THE WORD "SEWER" IN 3" LETTERS CAST THEREON 4'-0" DIA.COMBINATIONOF1,2,3,OR4'LENGTHS4'-0"8"8"24" DIA.12"TYP.ADJUST TO REQUIRED GRADE WITH A MIN. OF TWO COURSES OF BRICK MASONRY OR REINFORCED CONCRETE GRADING RINGS MANHOLE FRAME AND COVER MORTAR PRECAST REINFORCED CONCRETE MANHOLE BARREL 5" MIN. O-RINGS RUBBER GASKET JOINTS FORGED ALUMINUM SAFETY TYPE MANHOLE STEP WATERPROOF COATING TO BE APPLIED TO OUTER SURFACE UNDISTURBED EARTH PVC SEWER RUBBER RING WATER STOP A.C. MANHOLE COUPLING, A.C.-PVC ADAPTER BRICK MASONRY OR CONCRETE 12" MIN. SCREENED GRAVEL PRECAST CONCRETE BASE SECTION PRECAST REINFORCED CONCRETE MANHOLE CONE PIPE TO MANHOLE CONNECTIONS NOT TO SCALE CL PIPE PIPELC C PIPEL MORTAR JOINT FLEXIBLE SLEEVE COMPRESSION GASKET (CAST-IN) FORMED OPENING A-LOK RUBBER GASKET INSIDE FACE OF MANHOLE INSIDE FACE OF MANHOLE FORMED OPENING ANODIZED ALUMINUM OR STEEL KORBAND EXPOSED METAL TO BE PROTECTED FROM EROSION WITH A BITUMINOUS COAT STAINLESS STEEL CLAMP NEOPRENE KOR-N-SEAL BOOT INSIDE FACE OF MANHOLE NON SHRINK GROUT BY CONTRACTOR NOT TO SCALE WATER, DRAIN OR SEWER MAIN 5" MIN. 5" MIN WATER, DRAIN OR SEWER MAIN 6" MIN. 6" MIN. NOTES: 1. WHENEVER POSSIBLE WATER MAINS DRAIN LINES CROSSING SEWERS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 36" BETWEEN THE OUTSIDE OF THE WATER MAIN OR DRAIN LINE AND THE OUTSIDE OF THE SEWER. 2. SHOULD LOCAL CONDITIONS PREVENT AN 36" SEPARATION, BOTH THE WATER MAIN OR DRAIN LINE AND THE SEWER SHALL BE ENCASED IN CONCRETE ON EITHER SIDE OF THE CROSSING (SEE DETAIL). 3. WHEREVER POSSIBLE, THE WATER MAIN OR DRAIN LINE SHALL BE LAID ABOVE THE SEWER. PLAN VIEW ELEVATION CONCRETE ENCASED SEWER AND WATER/DRAIN CROSSING SEWER, DRAIN OR WATER MAIN SEWER, DRAIN OR WATER MAIN 4"MIN.10'10' 10'10'10'10'EXCAVATION IN LEDGE EXCAVATION IN EARTH UNPAVED PAVED TABLE NO. 1 PIPE SIZE (IN.)`A' (FT.) 8-12 15-18 24-30 36-48 48-72 0.7 0.8 1.0 1.5 2.0 NOTES: NOT TO SCALE SEWER AND DRAIN TRENCH (PVC OR RCP) COMPACTED BEDDING MATERIAL EXISTING GRADE SEE SPECIFICATIONS FOR FINISH GRADE COMMON FILL MATERIAL TO BE COMPACTED AS SPECIFIED COMMON FILL MATERIAL TO BE COMPACTED AS SPECIFIED, NO STONES LARGER THAN 6" PERMITTED IN THIS AREA PAVEMENT AND SUBBASE MATERIAL AS SPECIFIED SEWER OR DRAIN PIPE UNDISTURBED EARTH 6" MINIMUM IN ROCK 12" MINIMUM (SEE NOTE 2) `A' MINIMUM, SEE TABLE 1, COMPACTED BEDDING MATERIAL COMPACTED CRUSHED STONE A.S.T.M. DESIGNATION D448 (MASS. STANDARD M2.01.4) PLACED AGAINST UNDISTURBED SIDES AND BOTTOM OF TRENCH. (SEE NOTE 2) 1. SHEETING, WHEN REQUIRED, TO BE CUT OFF AT LEAST 5 FEET BELOW STREET AND A MINIMUM OF 1 FOOT ABOVE TOP OF PIPE. WOOD SHEETING DRIVEN BELOW MID-DIAMETER OF THE PIPE SHALL BE LEFT IN PLACE. STEEL SHEETING DRIVEN BELOW MID-DIAMETER MAY BE WITHDRAWN IF APPROVED IN WRITING BY THE ENGINEER. FOR PVC PIPE ALL SHEETING DRIVEN BELOW MID-DIAMETER SHALL BE LEFT IN PLACE. 2. WHEN APPROVED BY THE ENGINEER FOR PIPES OTHER THAN PVC SELECTED GRAVEL FILL MATERIAL MAY BE USED FROM MID-DIAMETER OF PIPE TO 12" ABOVE TOP OF PIPE. NO STONES LARGER THAN 2 INCHES IN ANY DIMENSION WILL BE PERMITTED IN THIS AREA - MASSACHUSETTS STATE MATERIAL STANDARD M1.03.0 TYPE C. 3. TRENCHES LOCATED ON THE ROAD SHOULDER SHALL BE TREATED THE SAME EXCEPT FOR PAVING. 4. PROVIDE AT LEAST ONE IMPERVIOUS DAM IN GRAVEL BEDDING BETWEEN EACH MANHOLE WHERE DIRECTED, OR EVERY 300 FEET, WHICHEVER IS LESS. 5. BEDDING MATERIAL FOR PVC PIPE SHALL MEET THE REQUIREMENTS OF ASTM D2321 CLASS I OR CLASS II EMBEDMENT MATERIALS. CRUSHED STONE BEDDING % FINER BY WEIGHT 90 - 100 SIEVE SIZE 1" 3/4" 100 3/8"20 - 55 0 - 10 0 - 5 # 4 # 8 NOT TO SCALE 1" CLEAR EJ FRAME 5448Z AND (2) GRATE 5520M5 OR APPROVED EQUAL. OUTSIDE PIPE DIAMETER PLUS 2" CLEARANCE 12" MIN. CRUSHED STONE (M2.01.4) MIN. 0.12 SQ. IN. STEEL PER VERTICAL FOOT, PLACED ACCORDING TO AASHTO DESIGNATION M-199 MORTAR ALL JOINTS BRICK LEVELING COURSE AS REQUIRED FOR GRADE ADJUSTMENTS (2 MIN.- 5 MAX.) FRAME TO BE SET IN FULL BED OF MORTAR PROVIDE 'V' OPENINGS 5'-0" DIA. 5" MIN.DIAMETEROFOUTLETPIPEX4(4'MIN.)HEIGHT OF RISER SECTIONS MAY VARY FROM 1' TO 4' NOTE: STRUCTURES & CASTINGS SHALL BE RATED FOR H-20 LOADING DOUBLE GRATE CONCRETE CATCH BASIN NOTE: DOUBLE-CURB INLETS SHALL BE USED AT ALL DOUBLE GRATE CATCH BASINS PROPOSED ALONG CURB LINES. NORMAL WATER LEVEL ROCK PAY LIMIT 12" ROCK PAY LIMIT OR SUBGRADEORDINARYBORROWPLACEDIN12"LIFTSOIL/WATER SEPARATOR 2 1 2' RIP-RAP SPECIFICATIONS: 1. MEDIAN STONE DIAMETER = 6"; 50% BY WEIGHT OF RIPRAP MIXTURE TO BE 6"; 25% TO BE 9"; 25% TO BE 3". 2. RIPRAP STONE TO BE CLEAN WASHED STONE. 3. FILTER FABRIC TO BE MIRAFI 140N, BY MIRAFI, INC. FILTER FABRIC; BURY ENDS MIN. 6" MEDIUM DUTY RIPRAP 18" DEEP 6" TYP. 6" TYP. FINISH GRADE RIPRAP SWALE NOT TO SCALE FORCE MAIN MANHOLE CONNECTION NOT TO SCALESLOPEDBENCHSLOPEDBENCHFLOW TYPICAL PRECAST MANHOLE OUTLET SEWERFORCE MAIN NON-SHRINK GROUT M.J. - FL. WALL PIPE 45° FL-FL 45° FL-MJ 3/4" CRUSHED STONE, 6" MIN (12" MIN. IN LEDGE) STRAIGHT PIECE AS REQUIRED MATCH PIPE CROWNS FINISH GRADE NOT TO SCALE FORCEMAIN GATE VALVE GATE VALVE CONCRETE SUPPORT UNDISTURBED EARTH ADJUSTABLE VALVE BOX W/ COVER H-20 RATED 5'-0"MIN.COVER TO MARKED "SEWER"www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:36:09PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-30ConceptualSitePlansHanoverHyannisIIDetailSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT BOLLARD NOT TO SCALE FINISH GRADE BOLLARD SHALL BE 6" O.D. EXTRA STRENGTH GALVANIZED PIPE FILLED W/ CONCRETE. PAINT 1 COAT PRIMER, 2 COATS COLOR.3"18" MIN.3'-0"3'-0"1"MIN.NOT TO SCALE PAVEMENT PATCH NON PAVEMENT AREAPAVEMENT AREA SEE TRENCH DETAIL RESTORE TO EXISTING CONDITIONS SAW CUT LIMIT OF TRENCH PAVEMENT PATCH TO BE SAME THICKNESS AS EXISTING PAVEMENT COAT EDGE OF PAVEMENT (SAW CUT) WITH RS-1 BITUMINOUS MATERIAL PRIOR TO PLACING PAVEMENT PATCH WOOD VEHICULAR GUARDRAIL NOT TO SCALE WOOD POST DETAIL SIDE ELEVATION FRONT ELEVATION 2"± 10"± NOTES: 1. ALL TIMBER TO BE PRESSURE TREATED. 2. POSTS TO BE SPACED CLOSER THAN 8'-0" ON CENTER AS REQUIRED TO MAINTAIN LOCATION OF GUARD RAIL ALONG EDGE OF DRIVE SEE POST DETAIL 4"X10" ROUGH SAWED WOOD RAIL 5 8" DIA. X 8" LAG BOLT WITH WOOD PLUG POSTS 8'=0" O.C.10"7"2"±CURB 27"2' MIN. 6"X8" WOOD POST 6'1-3/4"± 6"± 8 "± CEMENT LINED DUCTILE IRON (CLDI) PIPE TRENCH NOT TO SCALE UNPAVED PAVED EXCAVATION IN LEDGE EXCAVATION IN EARTH SCREENED GRAVEL SEE SPECIFICATIONS FOR FINAL GRADING COMMON FILL MATERIAL TO BE COMPACTED AS SPECIFIED, NO STONES LARGER THAN 6" PERMITTED IN THIS AREA PAVING AND SUBBASE MATERIAL AS SPECIFIED 5'-0"MIN.COVER1'-0"SELECT BACKFILL, NO STONES LARGER THAN 2" IN ANY DIMENSION WILL BE PERMITTED FROM THE TRENCH BOTTOM TO 12" ABOVE TOP OF PIPE. TYPICAL FOR EARTH OR LEDGE. 6" MINIMUM IN LEDGE BED BOTTOM QUADRANT ON UNDISTURBED EARTH. EXCAVATE BY HAND FOR BELL HOLES AND INSTALL PIPE SO THAT IT IS FIRMLY SUPPORTED FOR ITS LENGTH. BACKFILL TO BE INSTALLED IN LAYERS OF 6" FIRMLY TAMPED BY HAND TO 12" ABOVE PIPE FROM THE BOTTOM OF TRENCH. TYPICAL FOR EARTH OR LEDGE WATER MAINLC NOT TO SCALE TYPICAL HYDRANT AND VALVE FINISH GRADE 6" GATE VALVE MASONRY RING ADJUSTABLE VALVE BOX VARIES 3'-0" TEE CONNECTION 12"X12"X4" CONCRETE BLOCK CONCRETE THRUST BLOCK AGAINST UNDISTURBED MATERIAL (DO NOT BLOCK DRAIN) PROVIDE 0.5 C.Y. OF SCREENED GRAVEL OR GRAVE BACKFILL TO AT LEAST 6" ABOVE DRAIN HOLES CAST-IN-PLACE CONCRETE THRUST BLOCK AGAINST COMPACTED MATERIAL 5'-0"MIN.COVERHYDRANT TO BE ADJUSTED TO GRADE AS REQUIRED, ROTATE AS NECESSARY FINISH GRADE NOT TO SCALE TYPICAL GATE VALVE NOT TO SCALE RESTRAINED JOINT TEE TYPICAL VALVE CONNECTION GATE VALVE CONCRETE SUPPORT UNDISTURBED EARTH ADJUSTABLE VALVE BOX W/ COVER 5'-0"MIN.WATER MAIN TIE RODS SPOOL PIECE MJ GATE VALVE SOCKET CLAMP NUT & WASHER CAST-IN-PLACE CONCRETE CONCRETE THRUST BLOCK AGAINST COMPACTED MATERIAL NOT TO SCALE TABLE OF BEARING AREAS IN SQUARE FEET AGAINST UNDISTURBED MATERIAL FOR WATER MAIN FITTINGS SIZE OF MAIN (IN.) 45° BEND TEES & PLUGS 22 1/2° BEND 8" & LESS 10" 4 6 5 8 2 3 12"5129 16"71612 CONCRETE BACKING AGAINST UNDISTURBED MATERIAL CONCRETE BACKING AGAINST UNDISTURBED MATERIAL CONCRETE BACKING AGAINST UNDISTURBED MATERIAL MECHANICAL JOINT END PLUG 1'-6" MIN. OR AS REQUIRED TYPICAL GRAVITY WALL CROSS SECTION WITH HD BASE UNITS STONE STRONG (OR EQUAL) 6 SF RETAINING WALL TOP UNIT STONE STRONG (OR EQUAL) 24 SF RETAINING WALL UNIT STONE STRONG (OR EQUAL) 24-62 SF RETAINING WALL UNIT STONE STRONG (OR EQUAL) 24-86 SF RETAINING WALL UNIT NOTE: HYDRANTS SHALL BE MUELLER SUPER CENTURION, DRY BARREL, OPEN LEFT AND PAINTED RED. 2 1/2' MIN. SHEET FLOW RAIN GARDEN STORMWATER TREATMENT BASIN NOT TO SCALE SHEET FLOW UNDISTURBED SOIL SEE PLANTING PLAN RUNOFF DRAINAGE TO RAIN GARDEN FILTER SOIL 40% SAND 20%-30% LEAF COMPOST 20%-30% TOPSOIL FILTER STRIP FILTER STRIP RUNOFF DRAINAGE TO RAIN GARDEN VARIESUNDERDRAIN DETAIL FILTER FABRIC - MIRAFI 140N AS MANUFACTURED BY MIRAFI INC. OR APPROVED EQUAL 3/4"-1 1/2" WASHED STONE 4" HDPE PERFORATED PIPE UNDISTURBED EARTH 18"6"4" FILTER MEDIA FINISH GRADE 6"NOT TO SCALE www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:37:14PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-31ConceptualSitePlansHanoverHyannisIIDetailSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT PAVEMENT SECTION NOT TO SCALE COMPACTED SUB BASE 12" GRAVEL BASE COURSE (MASS. HIGHWAY SPEC. M1.03.0 GRAVEL BORROW) 3" MIN. BIT. CONC. PAVEMENT (MASS. HIGHWAY SPEC. TYPE I-1 PLACED IN TWO LAYERS 1 1/2" MIN. TOP, 1 1/2" MIN. BINDER) 6"x6" 6/6 WW MESH PAVEMENT CONCRETE COMPACTOR PAD NOT TO SCALE 12" GRAVEL BASE SEE GEOTECHNICAL REPORT FOR SUB BASE PREP 3/4" CHAMFER ALL TOP EDGES SEE SITE PLAN 6"3"2" 1" MINIMUM CEMENT CONCRETE WALK NOT TO SCALE COMPACTED SUBGRADE 4" CONCRETE SLAB FINISH GRADE 8" GRAVEL COMPACTED BASE SEE SITE PLAN 12"BRISTLE BROOM FINISH 6"x6"-#10 WIRE MESH CENTERED IN SLAB NOTE: IN AREAS THAT SIDEWALK ABUTS ROAD OR PARKING LOT CURBING SIDEWALK CROSS SLOPE TO BE DIRECTED TO CURB LINE. 1.5% MAXIMUM UNLESS SHOWN OTHERWISE. NOT TO SCALE CONCRETE CURB & SIDEWALK 1" (MIN.) 8"GRAVEL BASE FINISH GRADE COMPACTED SUBGRADE GRAVEL BASE COMPACTED SUBGRADE CEMENT CONCRETE WEARING COURSE BINDER COURSE 12" GRAVEL BASE PRECAST CONCRETE CURB 6"6" 6" 6"6"12"VARIES 4" THICK CONCRETE SLAB BRISTLE-BROOM FINISH 6"X6" - #10 WIRE MESHEXPANSION JOINT MATERIAL 18"NOTE: SIDEWALK CROSS SLOPE DIRECTED TO CURB LINE. 1.5% MAXIMUM UNLESS SHOWN OTHERWISE. L WSIDEWALK SIDEWALKSIDEWALK W L S.Y. 4'-0"3'-6"±5.2 5'-0"2'-9"±6.3 6'-0"2'-0"±7.2 7'-0"1'-3"±8.0 8'-0"0'-0"8.1 FACE OF CURB WHEEL CHAIR RAMP NOT TO SCALE 1 :1 2 S L O P E O R F L AT TER 1/2" MAX. FOR SIDEWALKS UP TO 8' WIDE PLAN SECTION A-A TRANSITION CURB WHEEL CHAIR RAMP CURB LINE AT EDGE OF PAVEMENT EDGE OF PAVEMENT TRANSITION CURB TRANSITION CURB SURFACE COURSE FOUNDATION EDGE OF PAVEMENT 6'-0" 3'-6" 6'-0" ADA COMPLIANT DETECTABLE WARNING STRIP (REQUIRED AT ALL RAMPS) NOTES: 1.) THE DETECTABLE WARNING SHALL BE A CAST-IN-PLACE COMPOSITE PANEL PAVER SYSTEM AS MANUFACTURED BY ADA SOLUTIONS, INC. COLOR SHALL BE BRICK RED. 2.) TRANSITIONS FROM CURB CUTS TO WALKS, GUTTERS, OR STREETS SHALL BE FLUSH. 3.) IF TRANSITION EXCEEDS .075FT/FT, THE TRANSITION MUST BE 0"-6" OVER 15' (MAX.) FOR CURB RUN. SIDEWALK WHEEL CHAIR RAMP AT DRIVE NOT TO SCALE 12:1 RAMP CURBCURBTRANSITION CURB ADA COMPLIANT DETECTABLE WARNING STRIP (REQUIRED AT ALL RAMPS) TRANSITION CURB 6'-0" LEVEL AREA 1.5% PREFERRED IN ALL DIRECTIONS (2% MAX) DETECTABLE WARNING - TRUNCATED DOMES ELEVATION (ENLARGED)PLAN 1. THE MAXIMUM ALLOWABLE ROUTE (SIDEWALK) AND CURB RAMP CROSS SLOPES SHALL BE 2.0% MAX. 2. THE MAXIMUM ALLOWABLE SLOPE OF ACCESSIBLE ROUTE CURB RAMPS SHALL NOT EXCEED 1:12 3. A MINIMUM OF 3 FEET CLEAR SHALL BE MAINTAINED AT ANY PERMANENT OBSTACLE IN ACCESSIBLE ROUTE (I.E., HYDRANTS, UTILITY POLES, TREE WELLS, SIGNS, ETC.. 4. BASE OF RAMP SHALL BE GRADED TO PREVENT PONDING. 5. SEE TYPICAL SIDEWALK SECTION FOR RAMP CONSTRUCTION. 6. ALL SLOPING SURFACES AT WHEEL CHAIR RAMPS FOR SIDEWALKS SHALL HAVE DETECTABLE WARNING-TRUNCATED DOMES AND COLOR CONCRETE 7. DETECTABLE WARNINGS SHALL CONSIST OF RAISED TRUNCATED DOMES WITH A DIAMETER OF NOMINAL 0.9 IN (23 MM), A HEIGHT OF NOMINAL 0.2 IN (5 MM) AND A CENTER-TO-CENTER SPACING OF NOMINAL 2.35 IN (60 MM) AND SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES, EITHER LIGHT-ON-DARK, OR DARK-ON-LIGHT. THE MATERIAL USED TO PROVIDE CONTRAST SHOULD CONTRAST BY AT LEAST 70%. CONTRAST IN PERCENT IS DETERMINED BY: CONTRAST = [(B1 - B2)/B1] X 100WHERE B1 = LIGHT REFLECTANCE VALUE (LRV) OF THE LIGHTER AREA AND B2 = LIGHT REFLECTANCE VALUE (LRV) OF THE DARKER AREA. B1 SHALL NEVER EQUAL 100 AND B2 SHALL ALWAYS BE GREATER THAN 0. 8. ALL PROPOSED WHEELCHAIR RAMPS SHALL HAVE A PEDESTRIAN WARNING SURFACE MEETING THE REQUIREMENTS OF THE ADA GUIDELINES. (SEE SPECIFICATIONS). ALL WHEELCHAIR RAMPS SHALL BE CONSTRUCTED WITH COLOR TINTED CONCRETE MEETING THE ADA GUIDELINES FOR CONTRASTING COLOR. FINAL COLOR TO BE DETERMINED BY THE ARCHITECT. ALL CONCRETE SHALL BE 4000 PSI PER ASTM C-260 AND THE PROJECT SPECIFICATIONS. 9. AT NO TIME IS ANY PART OF THE WHEELCHAIR RAMP TO BE LOCATED OUTSIDE OF THE CROSSWALK AND IT IS TO BE CENTERED WHENEVER POSSIBLE. 10. THE ENTRANCE OF THE WHEELCHAIR RAMP SHALL BE WITHIN 1/2" WITH THE ROADWAY. ACCESSIBLE CURB RAMP / ROUTE NOTES NOT TO SCALE 2.35"2.35"0.2"TOP DIAMETER OF 50-65% OF THE BASE DIAMETER BASE DIAMETER OF 0.9" NOT TO SCALE PAINTED CROSSWALK 6'-0"12" WIDE PAINTED SOLID WHITE STRIPE (TYPICAL)12"SIDEWALK 1'-6"3'-0"O.C.TYP.NOTE: CEMENT CONCRETE BACKING TO BE PROVIDED AT ALL JOINTS AND AT CURB MID SECTION FOR SPANS GREATER THAN 3 FEET. CONCRETE BACKING TO BE PLACED FROM BASE TO WITHIN 9 INCHES OF GRADE AND SPAN 1 FOOT AT JOINTS AND 1.5 FEET AT MID SECTION. NOT TO SCALE PRECAST CONCRETE CURB6"6" 6"6"18"24"6" FINISH GRADE PRECAST CONCRETE CURB CEMENT CONCRETE COMPACTED SUBGRADE GRAVEL BASE M1.03.0 TYPE "B" 12" GRAVEL BASE M1.03.0 TYPE "B" TOP COURSE BINDER COURSE 1 8 " NOT TO SCALE HANDICAP PARKING PAVEMENT MARKING27"26" 5 "83/4"6"21/4"5"LEVEL 1" LIP NOT TO SCALE BITUMINOUS CONCRETE BERM 5" REVEAL TOP COURSE BINDER COURSE COMPACTED SUBGRADE FINISH GRADE TACK BERM TO BASE COURSE SHOULDER 1'-0"1'-0"6"BIT. CONC. BERM 8" GRAVEL BASE NOTE: CEMENT CONCRETE BACKING TO BE PROVIDED AT ALL JOINTS AND AT CURB MID SECTION FOR SPANS GREATER THAN 3 FEET. CONCRETE BACKING TO BE PLACED FROM BASE TO WITHIN 9 INCHES OF GRADE AND SPAN 1 FOOT AT JOINTS AND 1.5 FEET AT MID SECTION. NOT TO SCALE VERTICAL GRANITE CURB6"6" 6"6"18"24"6" FINISH GRADE COMPACTED SUBGRADE VERTICAL GRANITE CURB GRAVEL BASE M1.03.0 TYPE "C" CEMENT CONCRETE TO BE USED ONLY IF CURB IS TO BE SET AFTER BASE AND / OR BINDER COURSE 12" GRAVEL BASE M1.03.0 TYPE "B" TOP COURSE BINDER COURSE HANDICAPPED PARKING SPECIAL PLATE REQUIRED OWNERS EXPENSE BE REMOVED AT VEHICLES MAY UNAUTHORIZED NOT TO SCALE HANDICAP PARKING SIGN SIGN PANEL SHALL BE FABRICATED FROM ALUMINUM SHEETING ASTM 3209, ALLOY 6061-T6, 0.080" THICK. SIGN SHALL HAVE TYPE D PERMANENTLY APPLIED LEGEND WITH `E' SILK SCREEN PROCESSED LEGEND SUPERIMPOSED THEREON POST TO BE SET IN CONCRETE, 18" DIA. MIN. 2 CUBIC FEET 2'-6"5'-6.5"1'-6"1'-0" CONCRETE WALKWAY WITH MONOLITHIC CONCRETE FOOTING NOT TO SCALE 18"6" 8' WALKWAY 8" COMPACTED GRAVEL BASE COMPACTED SUBGRADE BITUMINOUS CONCRETE PAVEMENT 4" CONCRETE WALK CONC. 4,500 P.S.I. AIR ENTRAINED 6"x6" W.W.F. #10 WIRE MESH 3 4" CHAMFER NOTE: SIDEWALK CROSS SLOPE DIRECTED TO CURB LINE. 1.5% MAXIMUM UNLESS SHOWN OTHERWISE. BRISTLE BROOM FINISH, TOOL EDGES AND JOINTS ALL PANELS 6'-0" 12" WIDE PAINTED SOLID WHITE STRIPE (TYPICAL)12"SIDEWALK 1'-6"3'-0"O.C.TYP.www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:37:48PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-32ConceptualSitePlansHanoverHyannisIIDetailSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT WQU # 1, 2, 7 & 8 CDS 1515-3-C WATER QUALITY UNIT WQU # 4, 5 & 6 CASCADE CDS-2015-4-C WATER QUALITY UNIT PLAN VIEW B-B N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET CENTER OF CDS STRUCTURE, SCREEN AND SUMP OPENING PVC HYDRAULIC SHEAR PLATE 1'-4" [406] ELEVATION A-A N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET SOLIDS STORAGE SUMP SEPARATION SCREEN INLET PIPE (MULTIPLE INLET PIPES MAY BE ACCOMMODATED)OUTLET PIPE PVC HYDRAULIC SHEAR PLATE FLOW OIL BAFFLE SKIRT CONTRACTOR TO GROUT TO FINISHED GRADE GRADE RINGS/RISERS A 36" [914] I.D. MANHOLE STRUCTURE TOP SLAB ACCESS (SEE FRAME AND COVER DETAIL) FRAME AND COVER (DIAMETER VARIES) N.T.S. F L O W BB www.contechES.com ® PERMANENT POOL ELEV. PLAN VIEW B-B N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET CENTER OF CDS STRUCTURE, SCREEN AND SUMP OPENING PVC HYDRAULIC SHEAR PLATE 1'-9" [533] ELEVATION A-A N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET SOLIDS STORAGE SUMP SEPARATION SCREEN INLET PIPE (MULTIPLE INLET PIPES MAY BE ACCOMMODATED) OUTLET PIPE PVC HYDRAULIC SHEAR PLATE FLOW PERMANENT POOL ELEV. OIL BAFFLE SKIRT CONTRACTOR TO GROUT TO FINISHED GRADE GRADE RINGS/RISERS A 48" [1219] I.D. MANHOLE STRUCTURE TOP SLAB ACCESS (SEE FRAME AND COVER DETAIL) FRAME AND COVER (DIAMETER VARIES) N.T.S. F L O W BB www.contechES.com ® PLAN VIEW B-B N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET CENTER OF CDS STRUCTURE, SCREEN AND SUMP OPENING HDPE HYDRAULIC SHEAR PLATE 1'-9" [533] ELEVATION A-A N.T.S. FIBERGLASS SEPARATION CYLINDER AND INLET SOLIDS STORAGE SUMP SEPARATION SCREEN INLET PIPE (MULTIPLE INLET PIPES MAY BE ACCOMMODATED)OUTLET PIPE HDPE HYDRAULIC SHEAR PLATE FLOW PERMANENT POOL ELEV. OIL BAFFLE SKIRT A 60" [1524] I.D. MANHOLE STRUCTURE TOP SLAB ACCESS (SEE FRAME AND COVER DETAIL) FRAME AND COVER (DIAMETER VARIES) N.T.S. F L O W CONTRACTOR TO GROUT TO FINISHED GRADE GRADE RINGS/RISERS BB www.contechES.com ® WQU #9 CDS 2015-5-C WATER QUALITY UNIT www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:38:28PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-33ConceptualSitePlansHanoverHyannisIIDetaoilSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT CULTEC RECHARGER 902HD HEAVY DUTY TYPICAL INTERLOCK CULTEC RECHARGER 902HD HEAVY DUTY THREE VIEW HIDDEN END HIDDEN END END OF RUN BEGINNING OF RUN MODEL 902HD MODEL 902HD MODEL 902HD END CAP MODEL 902HD END CAP CULTEC HVLV FC-48 FEED CONNECTOR TRIM CUT-OUT TO UTILIZE INTERNAL MANIFOLD FEATURE MODEL 902HD MODEL 902HD 78.0" 48.0" 78.0" 51.0" 44.0" INSTALLED LENGTH 51.0" SIDE PORTAL FOR OPTIONAL INTERNAL MANIFOLD (ACCOMMODATES CULTEC HVLV FC-48 FEED CONNECTOR OR STORM PIPE) MAXIMUM PIPE SIZE: 10" HDPE 12" PVC 6" DIA. INSPECTION PORT TRIM LOCATION CULTEC RECHARGER 902HD CHAMBER STORAGE = 17.31 CF/FT INSTALLED LENGTH ADJUSTMENT = 0.58' ZOOM OF SIDE PORTAL SHOWING MAX. PIPE O.D. MAX. PIPE: 10" HDPE 12" PVC8.3'MAX.COVERDEPTH78.0"93.0" CENTER TO CENTER 24"9.0"MIN.48.0"12.0"MIN.12.0"MIN.FORPAVED18.0"MIN.FORUNPAVEDCULTEC RECHARGER 902HD HEAVY DUTY CHAMBER IN CULTEC SEPARATOR ROWS MIN. 95% COMPACTED FILL OR GRANULAR SUB-BASE CULTEC HVLV FC-48 FEED CONNECTOR WHERE SPECIFIED 1-2 INCH WASHED, CRUSHED STONE SURROUNDING CHAMBERS PAVEMENT OR FINISHED GRADECULTEC NO. 410 NON-WOVEN GEOTEXTILE AROUND STONE. TOP AND SIDES MANDATORY, BOTTOM PER ENGINEER'S DESIGN PREFERENCE CHAMBERS SHALL BE DESIGNED AND TESTED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" CULTEC NO. 4800 WOVEN GEOTEXTILE TO BE PLACED BENEATH INTERNAL MANIFOLD FEATURE AND BENEATH ALL INLET/OUTLET PIPES (FOR SCOUR PROTECTION) PROJECT ENGINEER OF RECORD OR GEOTECHNICAL CONSULTANT IS RESPONSIBLE FOR ENSURING THAT THE REQUIRED BEARING CAPACITY OF SUB-GRADE SOILS HAS BEEN MET NOTES: 1. THE CHAMBERS SHALL BE DESIGNED AND TESTED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS." THE LOAD CONFIGURATION SHALL INCLUDE: 1.a. INSTANTANEOUS AASHTO DESIGN TRUCK LIVE LOAD AT MINIMUM COVER 1.b. MAXIMUM PERMANENT (50-YEAR) COVER LOAD 1.c. 1-WEEK PARKED AASHTO DESIGN TRUCK LOAD 2. THE CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F3430-20 "STANDARD SPECIFICATION FOR CELLULAR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" 3. THE INSTALLED CHAMBER SYSTEM SHALL PROVIDE RESISTANCE TO THE LOADS AND LOAD FACTORS AS DEFINED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12, WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS. THE STRUCTURAL DESIGN OF THE CHAMBERS SHALL INCLUDE THE FOLLOWING: 3.a. THE CREEP MODULUS SHALL BE 50-YEAR AS SPECIFIED IN ASTM F3430 3.b. THE MINIMUM SAFETY FACTOR FOR LIVE LOADS SHALL BE 1.75 3.c. THE MINIMUM SAFETY FACTOR FOR DEAD LOADS SHALL BE 1.95 TRAFFIC RATED CULTEC INSPECTION PORT KIT (SEE DETAIL) PAVEMENT OR FINISHED GRADE MIN. 95% COMPACTED FILL OR GRANULAR SUB-BASE CULTEC NO. 410 NON-WOVEN GEOTEXTILE AROUND STONE. TOP AND SIDES MANDATORY, BOTTOM PER ENGINEER'S DESIGN PREFERENCE 1-2 INCH WASHED, CRUSHED STONE SURROUNDING CHAMBERS INLET/OUTLET PIPE PER ENGINEER DESIGN. PIPE TO BE INSERTED 12.0" MIN. INTO CHAMBER MAXIMUM PIPE SIZE: 30" HDPE 36" PVC CULTEC RECHARGER 902HD HEAVY DUTY CHAMBER INLET STRUCTURE 24.0"MINSUMPTYPICAL CULTEC SEPARATOR ROW TO BE COVERED WITH CULTEC NO. 410 NON-WOVEN GEOTEXTILE 1 LAYER OF CULTEC NO. 4800 WOVEN GEOTEXTILE TO BE PLACED BENEATH ENTIRE SEPARATOR ROW NOTES: 1. THE CHAMBERS SHALL BE DESIGNED AND TESTED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS." THE LOAD CONFIGURATION SHALL INCLUDE: 1.a. INSTANTANEOUS AASHTO DESIGN TRUCK LIVE LOAD AT MINIMUM COVER 1.b. MAXIMUM PERMANENT (50-YEAR) COVER LOAD 1.c. 1-WEEK PARKED AASHTO DESIGN TRUCK LOAD 2. THE CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F3430-20 "STANDARD SPECIFICATION FOR CELLULAR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" 3. THE INSTALLED CHAMBER SYSTEM SHALL PROVIDE RESISTANCE TO THE LOADS AND LOAD FACTORS AS DEFINED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12, WHEN INSTALLED ACCORDING TO CULTEC'S RECOMMENDED INSTALLATION INSTRUCTIONS. THE STRUCTURAL DESIGN OF THE CHAMBERS SHALL INCLUDE THE FOLLOWING: 3.a. THE CREEP MODULUS SHALL BE 50-YEAR AS SPECIFIED IN ASTM F3430 3.b. THE MINIMUM SAFETY FACTOR FOR LIVE LOADS SHALL BE 1.75 3.c. THE MINIMUM SAFETY FACTOR FOR DEAD LOADS SHALL BE 1.95 CULTEC SEPARATOR ROW - CULTEC INSPECTION PORT DETAIL CULTEC RECHARGER 902HD HEAVY DUTY CROSS SECTION PROJECT ENGINEER OF RECORD OR GEOTECHNICAL CONSULTANT IS RESPONSIBLE FOR ENSURING THAT THE REQUIRED BEARING CAPACITY OF SUB-GRADE SOILS HAS BEEN MET PAVEMENT OR FINISHED GRADE PAVEMENT SUB-BASE (WHEN APPLICABLE) MINIMUM 95% COMPACTED FILL CULTEC NO. 410 NON-WOVEN GEOTEXTILE AROUND STONE. TOP AND SIDES MANDATORY, BOTTOM PER ENGINEER'S DESIGN PREFERENCE 12.0 INCH MIN. DEPTH OF 1-2 INCH WASHED CRUSHED STONE ABOVE CHAMBERS CULTEC RECHARGER 902HD HEAVY-DUTY CHAMBER CULTEC HVLV FC-48 FEED CONNECTOR WHERE SPECIFIED 9.0 INCH MIN. DEPTH OF 1-2 INCH WASHED CRUSHED STONE BENEATH CHAMBERS 12.0 INCH MIN. WIDTH OF 1-2 INCH WASHED CRUSHED STONE BORDER SURROUNDING ALL CHAMBERS12.0'MIN.CULTECNO.4800WOVENGEOTEXTILEPLACEDBENEATHINLETPIPES7.5'MIN.CULTECNO.4800WOVENGEOTEXTILEPLACEDBENEATHFEEDCONNECTORS8.0"MIN.24.0" MIN. 15.0"6.0"PAVEMENT OR FINISHED GRADE FIELD PLACED CLASS "C" CONCRETE (OPTION 1) 1.50" BELOW PAVEMENT 6" SDR-35 BELL END. CUT FOR 6" OF INSERTED PIPE 6" SDR-35 RISER (LENGTH VARIES) 12" X 6" CULTEC INLINE DRAIN / CLEAN-OUT BASIN w/ GASKETED SDR-35 CONNECTION 6" PVC SCREW IN CAP AASHTO HS-25 RATED CAST IRON FRAME AND SOLID COVER 6.25" HOLE TO BE CUT w/ HOLE SAW CENTERED ON CORRUGATION CREST PAVEMENT OR FINISHED GRADE MIN. 95% COMPACTED GRANULAR FILL FIELD PLACED CLASS "C" CONCRETE (OPTION 2) FLUSH WITH PAVEMENT PIPE PER ENGINEER DESIGN PIPE TO BE INSERTED 12.0 INCHES MIN. INTO CHAMBER MAXIMUM PIPE SIZE: 30" HDPE 36" PVC CULTEC RECHARGER 902HD HEAVY DUTY PLAN VIEW CULTEC INSPECTION PORT - ZOOM DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOTE: SEE GRADING AND DRAINAGE PLAN FOR LAYOUT FOR INSPECTION PORT LOCATIONS. CULTEC RECHARGER 902HD HEAVY DUTY END CAP THREE VIEW 78.0" 48.5" 28.0" 24.0" INSTALLED CULTEC RECHARGER 902HD END CAP INSTALLED STORAGE = 18.02 CF STORAGE = 9.01 CF/FT INSTALLED LENGTH ADJUSTMENT = 0.33' 78.0" 28.0" EJ FRAME 2114Z AND COVER 2110A1 OR APPROVED EQUAL. COVER SHALL BE FORGED WITH THE WORD DRAIN NOT TO SCALE DRYWELL FINISH GRADE PRECAST DRYWELL (H-20 LOADING) 8'-0" DIA.1'-0"1'-0" 10'-0"7'-0"3/4 - 1-1/2" DIA. CRUSHED STONE (WASHED) BRICK LEVELING COURSE AS REQUIRED FOR GRADE ADJUSTMENTS (2 MIN.- 5 MAX.)FRAME TO BE SET IN FULL BED OF MORTAR 1'-0"1'-0"www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:39:24PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-34ConceptualSitePlansHanoverHyannisIIDetailSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT PRACTICE: STABILIZED CONSTRUCTION EXIT POINTS: INSTALLATION: MAINTENANCE: · · PRACTICE: CONTROL DISCHARGES FROM SEDIMENT OR SOIL STOCKPILES PRACTICE CONCRETE WASHOUT AREAS INSTALLATION REQUIREMENTS: MAINTENANCE REQUIREMENTS: MATERIAL REMOVAL: MULCHING: PRACTICE PERIMETER CONTROLS: COMPOST FILTER TUBE : A COMPOST FILTER TUBE IS A TYPE OF CONTAINED COMPOST FILTER BERM CONSISTING OF A MESH TUBE FILLED WITH COMPOSTED MATERIAL THAT IS PLACED PERPENDICULAR TO SHEET-FLOW RUNOFF TO CONTROL EROSION AND RETAIN SEDIMENT IN DISTURBED AREAS. THE COMPOST FILTER TUBE ACTS AS A FILTER TO RETAIN SEDIMENT AND OTHER POLLUTANTS (E.G., SUSPENDED SOLIDS, NUTRIENTS) WHILE ALLOWING THE WATER TO FLOW THROUGH.IT. TUBES ARE ASSEMBLED BY TYING A KNOT IN ONE END OF THE MESH TUBE, FILLING THE TUBE WITH THE COMPOSTED MATERIAL (USUALLY USING A PNEUMATIC BLOWER), THEN KNOTTING THE OTHER END ONCE THE DESIRED LENGTH IS REACHED. INSTALLATION REQUIREMENTS: NO TRENCHING IS REQUIRED; THEREFORE, SOIL IS NOT DISTURBED UPON INSTALLATION. ONCE THE FILTER TUBE IS FILLED AND PUT IN PLACE, IT SHOULD BE ANCHORED TO THE SLOPE BY STAKES THROUGH THE CENTER OF THE TUBE AT REGULAR INTERVALS; ALTERNATIVELY, STAKES CAN BE PLACED ON THE DOWNSTREAM SIDE OF THE TUBE. THE ENDS OF THE FILTER TUBE SHOULD BE DIRECTED UPSLOPE, TO PREVENT STORMWATER FROM RUNNING AROUND THE END OF THE TUBE. MAINTENANCE REQUIREMENTS:. IF THERE IS EXCESSIVE PONDING BEHIND THE FILTER TUBE OR ACCUMULATED SEDIMENT REACHES THE TOP OF THE TUBE, AN ADDITIONAL TUBE SHOULD BE ADDED ON TOP OR IN FRONT OF THE EXISTING FILTER TUBE IN THESE AREAS. RIPPED OR TORN SECTIONS MUST BE REPLACED. PRACTICE: OUTLET STABILIZATION AND VELOCITY DISSIPATION INSTALLATION REQUIREMENTS: MAINTENANCE REQUIREMENTS: PRACTICE: SILT FENCE: INSTALLATION: MAINTENANCE: TEMPORARY SEEDING GEOTEXTILE CATCH BASIN INLET PROTECTION ALLOWS WATER FLOW WHILE TRAPPING SILT, SAND, AND SEDIMENTS. PIPE POCKET TO ACCEPT UP TO 2" DIAMETER SCHEDULE 80 PIPE. PIPE IS INSTALLED TO FACILITATE THE HOISTING OF THE FILLED BAG FROM THE CATCH BASIN INVERSION STRAPS. ONCE REMOVED FROM THE CATCH BASIN, THE BAG IS HOISTED FROM THE INVERSION STRAPS TO EMPTY THE CONTENTS TURNING THE BAG INSIDE OUT. CONSTRUCTED OF HIGH STRENGTH WOVEN GEOTEXTILE FABRIC. ALL SEAMS DOUBLE STITCHED WITH HEAVY DUTY MARINE QUALITY THREADS. ACF ENVIRONMENTAL MODEL # SIL T02X02 HIGH VISIBILITY YELLOW OR APPROVED EQUAL. NOTES: PRACTICE CATCH BASIN INLET PROTECTION: INLET PROTECTION MEASURES REMOVE SEDIMENT FROM THE DISCHARGE PRIOR TO ENTRY INTO CATCH BASIN INLETS. EXAMPLES OF INLET PROTECTION MEASURES INCLUDE EXCAVATIONS AROUND THE PERIMETER OF THE DROP INLET, FABRIC BARRIERS AROUND INLET ENTRANCE, BLOCK AND GRAVEL PROTECTION, AND STONE-FILLED BAG BERMS. THE VARIOUS TYPES ARE SPECIFIC TO THE GROUND COVER OF THE CONTRIBUTING AREA AS OUTLINED BELOW. INLET PROTECTION PRACTICES TYPICALLY FUNCTION BY SLOWING AND DETAINING SEDIMENT-LADEN RUNOFF AND ALLOWING SEDIMENT TO SETTLE OUT OF SUSPENSION. INLET PROTECTION MUST BE INSTALLED IN NEW CATCH BASINS INLETS IMMEDIATELY UPON INSTALLATION, AND INSTALLED IN EXISTING CATCH BASIN INLETS BEFORE ADJACENT AREAS ARE DISTURBED. SPECIFIC TYPES OF INLET PROTECTION FOR PAVED AND UNPAVED AREAS ARE AS FOLLOWS: GEOTEXTILE BARRIERS: POROUS WOVEN FABRIC PLACED INSIDE A CATCH BASIN INLET TO CREATE A SHIELD AGAINST SEDIMENT WHILE ALLOWING WATER TO FLOW INTO THE DRAIN. THIS METHOD INCLUDES SILT SACKS, FILTER FABRIC, A RING OF SILT FENCE, ETC. EXCAVATIONS: A SMALL EXCAVATION AROUND THE PERIMETER OF THE CATCH BASIN INLET CREATES A SMALL POOL THAT ALLOWS SEDIMENT TO SETTLE OUT OF SUSPENSION.THIS MAY BE USED IN NON-PAVED AREAS. GRAVEL/STONE BARRIERS: GRAVEL/STONE CAN BE USED TO SLOWING AND DETAINING SEDIMENT-LADEN RUNOFF AND ALLOW SEDIMENT TO SETTLE OUT OF SUSPENSION. IT IS IMPORTANT TO USE CLEAN, WASHED STONE AND PREVENT IT FROM BEING WASHED INTO THE STORM WATER MANAGEMENT CONVEYANCE SYSTEM. INSTALLATION REQUIREMENTS: THE CONTRACTOR MUST PROVIDE INLET PROTECTION FOR DISCHARGES TO ANY CATCH BASIN INLET THAT CARRIES STORMWATER FLOW FROM THE SITE DIRECTLY TO A SURFACE WATER OR MS4 (AND IT IS NOT FIRST DIRECTED TO A SEDIMENT BASIN, SEDIMENT TRAP, OR SIMILARLY EFFECTIVE CONTROL). THE CONTRACTOR MUST NOT ALLOW ACCUMULATED SEDIMENT TO BLOCK STORM DRAIN INLETS, THIS MAY CAUSE STORM WATER RUNOFF TO BYPASS THE STORM WATER CONVEYANCE SYSTEM AND CREATE PROBLEMS DOWN-SLOPE INCLUDING ADDITIONAL EROSION OR FLOODING. MAINTENANCE REQUIREMENTS: CLEAN, OR REMOVE AND REPLACE, THE PROTECTION MEASURES AS SEDIMENT ACCUMULATES, THE FILTER BECOMES CLOGGED, AND/OR PERFORMANCE IS COMPROMISED. WHERE THERE IS EVIDENCE OF SEDIMENT ACCUMULATION ADJACENT TO THE INLET PROTECTION MEASURE, THE DEPOSITED SEDIMENT MUST BE REMOVED BY THE END OF THE SAME WORK DAY IN WHICH IT WAS FOUND OR BY THE END OF THE FOLLOWING WORK DAY IF REMOVAL BY THE SAME WORK DAY IS NOT FEASIBLE. OVERLAPPING SECTIONS FORM CONNECTIONS STAKE ALTERNATE STAKING OPTION CLOSED END CONNECTION/ATTACHMENT DETAIL 18" MIN FLOW FLOW WORK AREA PROTECTED AREA PLAN VIEW SECTION AREA TO BE PROTECTED AND UNDISTURBED 12"MIN.COMPOST FILTER SOCK 2" X 2" X 36" WOODEN STAKES PLACED 10' O.C.12" DIAMETER COMPOST FILTER SOCK DISTURBED WORK SIDE AREA ALTERNATE STAKE LOCATION NOTES: 1. THE CONTRACTOR SHALL PROVIDE A 6' HIGH TEMPORARY CONSTRUCTION FENCE WITH DUST SCREEN THAT IS NON-TRANSPARENT AND TIGHTLY FASTENED TO THE FENCE. DUST SCREEN LOCATIONS SHALL BE COORDINATED WITH OWNER. 2. THE FENCE SHALL BE POST DRIVEN OR ANCHOR BASE AND CAPABLE OF WITHSTANDING HIGH WINDS WITHOUT MOVEMENT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR TO EXISTING CONDITIONS RESULTING PROPERTY DAMAGE FROM THE FENCE INSTALLATION. CONSTRUCTION FENCE WITH WIND SCREEN 6' WIND SCREEN ANCHOR BASE SEE NOTE 2 DRIVEN POST PRACTICE: CONSTRUCTION FENCE WITH WINDSCREEN ATTACH WINDSCREEN SECURELY TO FENCE; REATTACH AS NECESSARY TO MAINTAIN FABRIC AGAINST FENCE; DO NO LEAVE GAPS IN SCREENING. REPLACE WINDSCREEN FABRIC IF IT APPEARS RIPPED OR TORN. NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:40:16PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-35ConceptualSitePlansHanoverHyannisIIDetailSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT DRAINAGE 1) PRECAST CONCRETE MANHOLES SHALL CONFORM TO ASTM DESIGNATION C478. CONCRETE REQUIREMENTS SHALL BE 4000 PSI. 2) STANDARD CATCHBASIN SHALL CONSIST OF PRECAST REINFORCED RISER SECTIONS, CONE SECTION, AND A BASE SECTION CONFORMING TO THE TYPICAL CATCHBASIN DETAIL. ALL CATCHBASINS SHALL HAVE A MINIMUM 4-FOOT SUMP. 3) INSTALL STEPS IN ACCORDANCE WITH ASTM C-478, 12" O.C. IN ALL CATCHBASINS AND DRAIN MANHOLES DEEPER THAN 4 FEET. 4) MANHOLE AND PIPE JOINT/CONNECTION SHALL BE NON-SHRINK GROUT OR APPROVED EQUAL. 5) PIPE MATERIAL SHALL BE SMOOTH WALL HIGH DENSITY POLYETHYLENE PIPE AS MANUFACTURED BY ADVANCED DRAINAGE SYSTEMS, INC, OR APPROVED EQUAL. 6) INSTALLATION AND MATERIALS FOR ALL PIPES WITHIN 10-FEET OF A BUILDING ARE SUBJECT TO CONFORMANCE WITH 248 CMR (MASSACHUSETTS STATE PLUMBING CODE.) ELECTRIC 1) SPECIFICATIONS: ALL WORK SHALL BE IN ACCORDANCE WITH THE ELECTRIC COMPANY'S STANDARDS. THE NATIONAL ELECTRICAL SAFETY CODE, AND STATE AND LOCAL CODE REQUIREMENTS. 2) APPROVAL: CONTRACTOR SHALL OBTAIN APPROVAL OF PLAN BY THE WIRE INSPECTOR AND THE ELECTRIC COMPANY. PLANS SHALL SHOW THE LOCATION OF CONDUITS AND THEIR TYPE, SIZE, AND NUMBER. 3) PROVIDE ALL EXCAVATION AND BACK FILLING WORK REQUIRED FOR THE INSTALLATION OF ALL ELECTRIC FACILITIES. THIS SHALL INCLUDE EXCAVATING FOR CONDUITS, MANHOLES, AND/OR JUNCTION ENCLOSURES, AND PADS. 4) INSTALL ALL GROUNDING MATERIALS (IE. WIRE, GROUND, RODS, CONNECTORS, ETC.) AS SPECIFIED BY ELECTRIC COMPANY. PRIVATE UTILITY NOTES 1) THIS PLAN HAS BEEN PREPARED AS A SCHEMATIC REPRESENTATION OF THE PROPOSED ELECTRIC, TELEPHONE, FIRE ALARM, AND NATURAL GAS SYSTEMS. IT IS NOT THE INTENTION OF THIS DRAWING THAT EVERY DETAIL, DEVICE, ITEM OR PIECE OF EQUIPMENT BE SHOWN. FINAL DESIGN AND APPROVAL MUST BE OBTAINED FROM THE RESPECTIVE UTILITY COMPANIES FOR LOCATION OF TRANSFORMERS, CONDUITS, AND CONNECTIONS TO BUILDINGS. 2) ELECTRIC, TELEPHONE, AND GAS UTILITY SIZES, AND APPURTENANCES SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE TOWN AND REVIEWED AND APPROVED BY THE APPROPRIATE UTILITY COMPANIES. WATER 1) DUCTILE IRON PIPE SHALL BE CEMENT LINED, COAL TAR ENAMEL, DOUBLE COATED, PUSH-ON TYPE JOINT, AND SHALL CONFORM TO A21.51 (AWWA C151) CLASS 52 FOR SIZES 4 INCH THROUGH 12 INCH. 2) DUCTILE IRON FITTINGS SHALL CONFORM TO ANSI/AWWA C153/A21.53-84 (DUCTILE IRON COMPACT FITTINGS) PRESSURE RATING 350 PSI. 3) GATE VALVES AND TAPPING SLEEVE VALVES SHALL BE RESILIENT SEATED VALVES CONFORMING TO THE REQUIREMENTS OF AWWA STANDARD C509. THE VALVE SHALL OPEN LEFT AND BE PRESSURE RATED FOR 250 PSI WORKING PRESSURE. 4) VALVE BOXES SHALL BE THE 2 PIECE SLIP TYPE, 5 1/4 INCH I.D., FLANGE LOCATED AT THE TOP OF THE BOX, COVER MARKED "WATER" EQUAL TO TYPE CURRENTLY BEING USED BY THE TOWN. 5) WATER PRESSURE REQUIREMENTS AND THE ACTUAL WATER PRESSURE TO BE PROVIDED AT THE BUILDING SHALL BE DETERMINED BY OTHERS. 6) THE CONTRACTOR WILL FURNISH AND INSTALL DOMESTIC WATER METERS AS SPECIFIED BY THE WATER DISTRICT. 7) WATER LINES MUST BE A MINIMUM OF (18) INCHES ABOVE SEWER LINES. IN ADDITION, ONE FULL LENGTH OF WATER MAIN MUST BE CENTERED ON ONE FULL LENGTH OF SEWER LINE SO THAT ALL JOINTS WILL BE AS FAR FROM THE SEWER AS POSSIBLE. 8) WATER SYSTEMS SHALL BE CONSTRUCTED IN ACCORDANCE WITH U.S. DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE, PHS (PUBLIC HEALTH SERVICE) MANUAL OF INDIVIDUAL WATER SYSTEMS, PHS PUBLICATION NO. 24, REVISED 1962, WASHINGTON, GPO (GOVERNMENT PRINTING OFFICE), 1963 AND ANY APPLICABLE CURRENT STATE AND FEDERAL REGULATIONS. 9) CHLORINATION SHALL BE IN ACCORDANCE WITH THE AWWA STANDARD C601 DISINFECTING WATER MAINS. 10) ALL PIPELINES SHALL BE GIVEN COMBINED PRESSURE AND LEAKAGE TESTS AT THE DIRECTION OF THE TOWN WATER DEPARTMENT. HYDROSTATIC AND LEAKAGE TEST SHALL BE MADE IN ACCORDANCE WITH AWWA STANDARD C600 SECTION 4. HYDROSTATIC TESTS SHALL BE MADE AT 1.5 TIMES THE WORKING PRESSURE, BUT NOT LESS THAN 150 PSI FOR A PERIOD OF NOT LESS THAN 2 HOURS IN ACCORDANCE WITH THE ABOVE AWWA STANDARD. 11) INSTALLATION OF WATER UTILITIES TO BE IN CONFORMANCE WITH THE WATER DISTRICT STANDARDS. 12) WHENEVER POSSIBLE WATER MAINS CROSSING SEWERS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18" BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SEWER. 13) SHOULD LOCAL CONDITIONS PREVENT AN 18" SEPARATION, BOTH THE WATER MAIN AND THE SEWER SHALL BE ENCASED IN CONCRETE ON EITHER SIDE OF THE CROSSING (SEE DETAIL). GENERAL CONSTRUCTION NOTES 1) THIS SET OF PLANS SHALL NOT BE UTILIZED AS CONSTRUCTION DOCUMENTS UNTIL ALL CONDITIONS OF APPROVAL HAVE BEEN SATISFIED ON THE DRAWINGS AND EACH DRAWING HAS BEEN REVISED TO INDICATE "ISSUED FOR CONSTRUCTION." 2) ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN RULES AND REGULATIONS UNLESS OTHERWISE NOTED. 3) ALL UTILITY PROVIDERS MUST BE NOTIFIED BY THE CONTRACTOR AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 4) WHILE WORKING IN THE VICINITY OF AN EXISTING UTILITY, REFER TO THE FOLLOWING: ALL UNDERGROUND UTILITIES SHOWN WERE COMPILED ACCORDING TO AVAILABLE RECORD PLANS FROM THE VARIOUS UTILITY COMPANIES AND PUBLIC AGENCIES AND ARE APPROXIMATE ONLY. SEE CHAPTER 370, ACTS OF 1963, MASSACHUSETTS GENERAL LAWS. WE ASSUME NO RESPONSIBILITY FOR DAMAGES INCURRED AS A RESULT OF UTILITIES OMITTED OR INACCURATELY SHOWN. BEFORE PLANNING FUTURE CONNECTIONS, THE APPROPRIATE PUBLIC ENGINEERING DEPARTMENT SHALL BE CONTACTED AND THE PROPOSED UTILITY WORK SHALL BE COORDINATED. DIG SAFE NUMBER; 1-888-344-7233. 5) THE CONTRACTOR SHALL GIVE TIMELY NOTICE TO PERTINENT TOWN DEPARTMENTS BEFORE COMMENCING ANY WORK. 6) ALL AREAS DISTURBED BY THE CONTRACTOR SHALL BE RESTORED TO EQUAL OR BETTER CONDITION. 7) ALL FINISHED SURFACES SHALL BE GRADED SMOOTHLY AND EVENLY. 8) AT THE COMPLETION OF THE CONTRACTOR'S OPERATION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING ALL DRAINAGE STRUCTURES (NEW AND/OR EXISTING) OF DEBRIS. 9) DO NOT SCALE PLANS. DUE TO REPROGRAPHIC STRETCH, PRINTS MAY NOT SCALE ACCURATELY. NUMERIC DIMENSIONING IS CORRECT. CONTACT DESIGN ENGINEER TO CLARIFY. 10) FILL CONTAINING HAZARDOUS MATERIALS SHALL NOT BE USED. 11) LIMITS OF WORK SHALL BE MARKED IN THE FIELD PRIOR TO THE START OF CONSTRUCTION. 12) ALL CONSTRUCTION WHICH INCLUDES HAULING OF EARTH TO OR FROM THE SITE SHALL BE RESTRICTED BETWEEN THE HOURS OF 7:00 AM AND 6:00 PM ON WEEKDAYS. 13) THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ADEQUATE RECORDS OF LOCATION AND ELEVATION OF ALL WORK INSTALLED. 14) IT IS THE CONTRACTORS RESPONSIBILITY TO OBTAIN THE ELECTRONIC FILE FROM TETRA TECH FOR PROPER COORDINATION OF SURVEY LAYOUT. 15) PRESERVATION OF ON SITE VEGETATION SHALL BE REVIEWED AND APPROVED BY OWNERS REPRESENTATIVE PRIOR TO THE START OF CONSTRUCTION. EROSION PREVENTION AND SEDIMENT CONTROL NOTES 1. THE BEST MANAGEMENT PRACTICES PROVIDED HEREIN REPRESENT THE MINIMUM MEASURES TO BE EMPLOYED DURING EACH PHASE OF CONSTRUCTION. SPECIFIC SEQUENCING PLANS WILL BE DEVELOPED FOR EACH PHASE OF CONSTRUCTION AS DESIGN IS ADVANCED. 2. THE CONTRACTOR MUST PERFORM ACTIVITIES IN ACCORDANCE WITH THE REQUIREMENTS OF THE GENERAL PERMIT FOR DISCHARGES FROM CONSTRUCTION ACTIVITIES. 3. THESE EROSION AND SEDIMENTATION PLANS ARE PART OF THE STORMWATER POLLUTION PREVENTION PLAN. 4. NO LAND CLEARING, GRUBBING OR GRADING ACTIVITIES, EXCEPT THAT REQUIRED FOR INSTALLATION OF THE CONSTRUCTION EXIT, SHALL BEGIN UNTIL PERIMETER SEDIMENT CONTROL MEASURES AND STORMWATER MANAGEMENT PRACTICES ARE CONSTRUCTED AND STABILIZED. 5. TEMPORARY STABILIZATION PRACTICES MUST BE INITIATED AS SOON AS PRACTICABLE ON PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN 14 DAYS AFTER CONSTRUCTION ACTIVITY IN THAT PORTION OF THE SITE HAS TEMPORARILY OR PERMANENTLY CEASED. 6. SEDIMENT MUST BE REMOVED FROM TRAPS OR PONDS WHEN THE DESIGN CAPACITY HAS BEEN REDUCED BY 50%. 7. SEDIMENT MUST BE REMOVED FROM A SILT FENCE, COMPOST FILTER SOCK OR STRAW WATTLE WHEN IT REACHES 50% OF THE ABOVE-GROUND HEIGHT. 8. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED BY THE CONTRACTOR IF DEEMED NECESSARY BY ON- SITE INSPECTION. 9. IF ADDITIONAL EROSION OR SEDIMENT CONTROL MEASURES ARE NECESSARY, THEY MUST BE IMPLEMENTED BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. IF NOT PRACTICABLE BEFORE THE NEXT STORM EVENT, THEY MUST BE IMPLEMENTED AS SOON AS POSSIBLE. 10. OFF SITE SEDIMENT TRACKING MUST BE MINIMIZED. SEDIMENT TRACKED ONTO ADJACENT PUBLIC WAYS MUST BE SWEPT BY THE END OF THE SAME WORK DAY. 11. STORMWATER RUNOFF FROM EXPOSED SURFACES MUST BE DIVERTED, RETAINED/DETAINED TO MINIMIZE THE DISCHARGE OF POLLUTANTS. 12. VELOCITY DISSIPATION DEVICES MUST BE INSTALLED AT DISCHARGE LOCATIONS OF ANY OUTFALL TO PROVIDE NON-EROSIVE FLOW VELOCITY. 13. PREVENT LITTER, CONSTRUCTION DEBRIS AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORMWATER FROM BECOMING A POLLUTANT SOURCE IN STORMWATER DISCHARGES.www.tetratech.comMARKDATEDESCRIPTIONBY4/15/20258:41:08PM-P:\26700\143-26700-23001\CAD\SHEETFILES\C-DETAILSHEET.DWG-CHEAL,NATE1 A B C D E F 2 3 4 5 6 7 Bar Measures 1 inch Copyright:TetraTechC-36ConceptualSitePlansHanoverHyannisIIDetailSheet100NickersonRoad Marlborough,MA01752PHONE:(508)786-2200FAX:(508)786-220118/2/2421/27/2534/16/25APPLICANT:HANOVERR.S.LIMITEDPARTNERSHIP1MARINAPARKDRIVESUITE701BOSTON,MA02210ZONINGCLASSIFICATION:MIXED-USESUBZONEOFTHEMEDICALSERVICESOVERLAYDISTRICT