HomeMy WebLinkAboutCOA 90 Pine StreetINSTALLATION OF NEW ROOF MOUNTED
PV SOLAR / ENERGY STORAGE SYSTEM
90 PINE STREET
WEST BARNSTABLE, MA 02668
41.6935, -70.3773
PINE STREET
P1 ISSUED TO TOWNSHIP FOR PERMIT 1/23/2025
NO.DESCRIPTION DATE
DEVINE, BRYCSON (SOLAR STORAGE)
TRINITY ACCT #: 2024-10-1196187
90 PINE STREET
WEST BARNSTABLE, MA 02668
41.6935, -70.3773
PROPOSED PV SOLAR /
ENERGY STORAGE SYSTEM
DRAWING DATE:1/23/2025
DRAWN BY:FJ
REVISED BY:
DC SYSTEM SIZE:9.84kW
AC SYSTEM SIZE:11.5kW
MODULE COUNT:24
MODULES USED:HANWHA 410
MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 410
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:74001391900
UTILITY METER #:2287225
DEAL TYPE:SUNNOVA
P1
(9.84kW SITE EXPORT)
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
ROOF 1 MODULES: 9 PITCH: 18 ORIENTATION: 84
ROOF 2 MODULES: 10
PITCH: 18 ORIENTATION: 264
ROOF 3 MODULES: 5 PITCH: 51
ORIENTATION: 264
ROOF 4
MODULES: 0 PITCH: 51° ORIENTATION: 84°
ROOF 5 MODULES: 0 PITCH: 16° ORIENTATION: 84°
ROOF 6 MODULES: 0 PITCH: 16° ORIENTATION: 264°
DC
AC
G
epM
DC
AC
***NOTE: 2021 NFPA 1 - 11.12.3.2.4.1
PLAN VIEW TOTAL ROOF AREA: 1463.3 FT²
PHOTOVOLTAIC ARRAY TOTAL AREA: 455.5 FT²
ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 31.1%NS27090
1
3
5
22545315DC
AC
G
epM
DC
AC
41.6935, -70.3773
24 HANWHA 410 (Q.PEAK DUO BLK ML-G10+ 410)
1 TESLA (BACKUP GATEWAY 2)
1 TESLA 11.5kW (POWERWALL 3)
1 TESLA AC COUPLED (POWERWALL 3)
INSIDE OUTSIDE.
OUTSIDE (UTILITY ACCESSIBLE)
P1 ISSUED TO TOWNSHIP FOR PERMIT 1/23/2025
NO.DESCRIPTION DATE
DEVINE, BRYCSON (SOLAR STORAGE)
TRINITY ACCT #: 2024-10-1196187
90 PINE STREET
WEST BARNSTABLE, MA 02668
41.6935, -70.3773
PROPOSED PV SOLAR /
ENERGY STORAGE SYSTEM
DRAWING DATE:1/23/2025
DRAWN BY:FJ
REVISED BY:
DC SYSTEM SIZE:9.84kW
AC SYSTEM SIZE:11.5kW
MODULE COUNT:24
MODULES USED:HANWHA 410
MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 410
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:74001391900
UTILITY METER #:2287225
DEAL TYPE:SUNNOVA
P1
(9.84kW SITE EXPORT)
NOTES:
1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2.)
3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
M
UD SP
P
DC
AC
ep
D
DC
SD
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.comG
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
REQUIRED CONDUCTOR AMPACITY PER STRING
[NEC 690.8(B)(1)]: (11.20*1.56)1 = 17.47A
AWG #10, DERATED AMPACITY
AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96
RACEWAY DERATING = 8 CCC: 0.70
(40*.96)0.70 = 26.88A
26.88A >_ 17.47A, THEREFORE WIRE SIZE IS VALID
TOTAL AC REQUIRED CONDUCTOR AMPACITY
48.00A*1.25 = 60.00A
AWG #6, DERATED AMPACITY
AMBIENT TEMP: 30°C, TEMP DERATING: 1.0
RACEWAY DERATING <_ 3 CCC: N/A
75A*1.0 = 75A
75A >_ 60.00A, THEREFORE AC WIRE SIZE IS VALID
CALCULATION FOR PV OVERCURRENT PROTECTION
TOTAL INVERTER CURRENT: 48.00A
48.00A*1.25 = 60.00A
--> 60A OVERCURRENT PROTECTION IS VALID
ARRAY CIRCUIT WIRING NOTES
1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2023
2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT
TEMP = -16°C
3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED
ON ASHRAE HIGHEST MONTH 2% DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP =
33°C
4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN
TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED
STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9
CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED
SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING
THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS
(ALL OF UNITED STATES)
5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH
NEC 690.12(A) THROUGH (D)
6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC
SOURCE AND OUTPUT CIRCUIT PER NEC 690.41 (A)(4)
7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
POSITIVE CONDUCTORS = RED
NEGATIVE CONDUCTORS = BLACK
NEC 210.5(C)(2)
8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT
SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL
CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤
9 CURRENT CARRYING CONDUCTORS.
9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS
OTHERWISE NOTED
10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON
ROOFTOP AND SHALL BE LIMITED TO 12” IF USED
OUTDOORS
11.) DISCONNECTS FED BY SUPPLY-SIDE SOURCE
CONDUCTORS SHALL BE BONDED AND CONNECTED TO
GROUNDING SYSTEM IN ACCORDANCE WITH
NEC 250.24
12.)OVERCURRENT PROTECTION FOR CONDUCTORS
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE
LOCATED WITHIN 10' OF THE POINT OF CONNECTION
NEC 690.9(A)(3)(2)
13.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A
UTILITY AND THE OTHER AN INVERTER, PV BACKFEED
BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY
NEC 705.12(B)(2)
14.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR
LOADS
15.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING
BACKUP GATEWAY
TESLA (BACKUP GATEWAY 2)
OCPD 100A
AIC MAX 10kA
Vnom 240
A 1 - #2 ALU. SEU CABLE
B 1 - #2 ALU. SER CABLE
C 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#10 THWN-2 GROUND
D 1 1/4'' CONDUIT W/ 4-#6 THWN-2, 2-#6 THWN-2, 2-#10 THWN-2 GROUND
E 3/4'' CONDUIT W/ 8-#10 THWN-2, 1-#10 THWN-2 GROUND
F #10 PV WIRE (FREE AIR) W/ #8 BARE COPPER BOND TO ARRAY
G LOW VOLTAGE COMMUNICATION (STANDARD RS485)
NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS
PV MODULE SPECIFICATIONS
HANWHA 410 (Q.PEAK DUO BLK ML-G10+ 410)
Imp 10.89
Vmp 37.64
Voc 45.37
Isc 11.2
EXISTING
MAIN BREAKER LOAD CENTERNEUTRAL240V1Ø2p100AMAIN100A MAIN BREAKER
100A BUSBAR
NEUTRAL
NEW
BACKUP GATEWAY
1Ø
CT METERS
2p60A
B
2p60A
MEXISTING
1Ø 120/240V
UTILITY METER
A
2p100A
MAIN
240V
-+L1L2NSOLAR MODULES MOUNTED TO ROOF ON 3 ARRAYS
24 - 410W MODULES W/ 1 TESLA MCI-2 PER 3 MODULES
14 ADC MAX PER STRING
1 STRING OF 9 MODULES IN SERIES - 463.41 Vmax (R1)
1 STRING OF 5 MODULES IN SERIES - 257.45 Vmax (R2)
1 STRING OF 5 MODULES IN SERIES - 257.45 Vmax (R2)
1 STRING OF 5 MODULES IN SERIES - 257.45 Vmax (R3)
*4 STRINGS TO BE TERMINATED INSIDE INVERTER 1
INVERTER / BATTERY #1
-+L1L2NCC
G
F 8"x8"
JUNCTION
BOX
INVERTER / BATTERY #2
E
D
G
INVERTER / BATTERY #2
DC AC
Imp -Pout 11500
Vmp -Imax 48
Voc -OCPDmin 60
Isc -Vnom 240
ENERGY 13.5kWh
INVERTER / BATTERY #1
DC AC
Imp 43.56 Pout 11500
Vmp 338.76 Imax 48
Voc 463.41 OCPDmin 60
Isc 56 Vnom 240
ENERGY 13.5kWh
POWERWALL 3 UNIT(S) TO BE SET TO: DEFAULT (SOLAR ONLY) - THE BATTERY IS
COMMANDED TO NOT EXPORT BEYOND THE SITE METER. THE EXPORT AT THE SITE
METER WILL BE LIMITED TO THE AMOUNT MEASURED BY THE SOLAR METER.
BATTERIES SHALL NOT DISCHARGE TO THE GRID.
PV SYSTEM / INVERTER SITE EXPORT SHALL NOT EXCEED DC SYSTEM RATING.
***NOTE:
PV SHALL NOT BE CONNECTED TO UNIT #2
***NOTE:
P1 ISSUED TO TOWNSHIP FOR PERMIT 1/23/2025
NO.DESCRIPTION DATE
DEVINE, BRYCSON (SOLAR STORAGE)
TRINITY ACCT #: 2024-10-1196187
90 PINE STREET
WEST BARNSTABLE, MA 02668
41.6935, -70.3773
PROPOSED PV SOLAR /
ENERGY STORAGE SYSTEM
DRAWING DATE:1/23/2025
DRAWN BY:FJ
REVISED BY:
DC SYSTEM SIZE:9.84kW
AC SYSTEM SIZE:11.5kW
MODULE COUNT:24
MODULES USED:HANWHA 410
MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 410
UTILITY COMPANY:EVERSOURCE
UTILITY ACCT #:74001391900
UTILITY METER #:2287225
DEAL TYPE:SUNNOVA
P1
(9.84kW SITE EXPORT)
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
JOB NAME:DEVINE, BRYCSON (SOLAR STORAGE)
ADDRESS:90 Pine Street
West barnstable, MA 02668
41.6935, -70.3773
65.96 ESTIMATED PERSONNEL HOURS 2.75 DAYS 2.06 DAYS 1.37 DAYS
•24 HANWHA 410's (9.84KW)(CREW OF 3)(CREW OF 4)(CREW OF 6)
•3 SEPARATE ARRAYS
•17' PEAK TO GROUND
•5 PORTRAIT & 19 LANDSCAPED
•1 INVERTER(S) INSTALLED OUTSIDE
•NO TRENCH
ESTIMATED SENT TO JOB USED
□HANWHA 410 (Q.PEAK DUO BLK ML-G10+ 410)24 ______
□TESLA MCI-2 9 ______
□TESLA (BACKUP GATEWAY 2)1 ______
□TESLA (POWERWALL 3)2 ______
□60A OUTDOOR NON-FUSED DISCONNECT 1 ______
□SOLADECK BOX(ES) & HAYCO CONNECTOR(S)3 ______
□PV LEAD WIRE 200'______
□ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 23 ______
□ECOFASTEN 2012013 CF RAIL SPLICE 9 ______
□ECOFASTEN 2099017 CF END CLAMP 32MM BLK 36 ______
□ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 30 ______
□ECOFASTEN 4011011 MODULE JUMPER 6 ______
□GROUNDING LUG(S)3 ______
□ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 90 ______
□ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8X10 90 ______
□ECOFASTEN 3016018 SCREW #14X3 W/BW 90 ______
□ECOFASTEN 2012019 CF MLPE MOUNT 24 ______
□ECOFASTEN 2012020 CF WIRE MGMT CLIP 24 ______
□ECOFASTEN 2012024 CF END CAP 36 ______
□2p60A BREAKER 2 ______
MATERIAL LIST
(FOR INTERNAL USE ONLY)
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
INSTALLATION OF NEW ROOF MOUNTED
PV SOLAR / ENERGY STORAGE SYSTEM
90 PINE STREET
DEVINE, BRYCSON (SOLAR STORAGE)
90 PINE STREET
WEST BARNSTABLE, MA 02668
41.6935, -70.3773
APPENDIX
CONTENTS
LABELS, STICKERS, AND PLACARDS
EQUIPMENT DATA SHEETS
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
WEST BARNSTABLE, MA 02668
152003001
WEST BARNSTABLE DEER CLUB INC
PO BOX 522
Property ID:
19 CUTLER STREET
LEOMINSTER, MA 01453
153001
MORALES, CARLOS E & GLORIA P TRS
MORALES FAMILY REVOCABLE TRUST
Property ID:
HYANNIS, MA 02601
153002
BARNSTABLE, TOWN OF (CEM)
367 MAIN STREET
Property ID:
WEST BARNSTABLE, MA 02668
153024
DEVINE, BRYCSON J & CHRISTINA M
90 PINE STREET
Property ID:
WEST BARNSTABLE, MA 02668
153025
DOMINATTO, CELIO A & NANCY B
134 PINE STREET
Property ID:
226 OLD LANCASTER ROAD
SUDBURY, MA 01776-2212
153029
MCCORMICK, DAVID W JR, PR
ESTATE OF JANE F MCCORMICK
Property ID:
WEST BARNSTABLE, MA 02668
153031001
DOLGOFF, ARTHUR L & SHIRLEY A
19 MCCORMICK DRIVE
Property ID: