HomeMy WebLinkAboutBarnstable - RDA - EJ Jaxitmer - 1450 1500 Osterville West Barnstable RoadDEVELOPED PROFILE OF SEPTIC LINE NOT TO SCALE DESIGN DATA Existing System Design Flow = 330 GPD P#2017-160 Proposed Single Family - 2 Bedroom @ 110 GPD No Garbage Grinder 1 Bedroom Reserved For Future Use Total Daily Flow = 330 GPD SEPTIC TANK 330 GPD X 200% = 660 Gallons Existing 1500 Gal 2 Compartment Septic Tank LEACHING AREA 330 GPD / 0.74 (LTAR) = 446 SF Required Existing 15' X 30' Bed = 450 SF (333 GPD) LEACHING AREA DESIGN All Pipes Schedule 40 With Ends Vented. 3 - 4"Ø Distribution Lines in a 15' x 30' Double Washed Stone Field as Shown. SEPTIC NOTES 1. Location of Utilities Shown on This Plan Are Approx. At Least 72 Hours Prior to Any Excavation For This Project the Contractor Shall Make the Required Notification to Dig Safe (1-888-344-7233) and contact Sullivan Engineering & Consulting Inc. (508-428-3344). 2. The Contractor is Required to Secure Appropriate Permits From Town Agencies For Construction Defined by This Plan. 3. Wherever Sewer Lines Must Cross Water Supply Lines Both Lines Shall Be Constructed of Class 150 Pressure Pipe and Shall be Water Tested to Assure Watertightness. In General, Water Lines Shall be Constructed in Coordination With COMM Water, and Shall be in Accordance With 248 CMR 1.00 - 7.00 & 310 CMR 15.00. 4. A Minimum of 9" of Cover is Required for All Components. 5. All Structures Buried Three Feet or More or Subject to Vehicular Traffic to be H-20 Loading. It is the Engineer's Recommendation that H-20 Always be Used. 6. Install Watertight Risers and Covers to Within 6" of Finished Grade Over Septic Tank Inlet and Outlet, D-Box, and One Leaching Chamber. All covers are to be maximum 18" for concrete or 24" Cast Iron. 7. Septic System to be Installed in Accordance With 310 CMR 15.00 & 248 CMR 1.00 - 7.00 Latest Revision and the Town of Barnstable Board of Health Regulations. 8. All Piping to be Sch. 40 PVC. 9. D-Box Shall Have a Minimum Inside Dimension of 12", and a Minimum Sump of 6". 10. The Separation Distance Between the Septic Tank Inlets and Outlets Shall be No Less than the Liquid Depth. Inlet Tees Shall Extend a Minimum of 10" Below the Flow Line. Outlet Tees Shall Extend 14" Below the Flow Line, and Shall be Equipped With a Gas Baffle.Osterville - West Barnstable RoadLocus 1 1FLOOD ZONE: ASSESSORS REF.: OVERLAY DISTRICT: LOCATION MAP: ZONE: Site PlanProposed Improvements At1450-1500 OstervilleWest Barnstable Rd.Barnstable (Marstons Mills) Mass. REFERENCES: DIRECTIONS: