HomeMy WebLinkAboutAP-2025-039 ElevationsDorm
Stair 1
218
Elevator 2
Lobby
2007'-4" (finish)10"1'-2"4'-0"23'-812" (confirm dimensions with elevator mfgr.12'-7" to hoist beam (verify with mfgr.)Job Number269 South Main StreetDateDrawn ByRevisedc 2025(508) 612-8771Centerville, MA 02632High Point Treatment Center2510For High Point Treatment Center, Inc.60 Perseverance WayHyannis, MA 02601Bid Drawings - not for permitting or constructionNorthA-9Oct. 30, 2025Elevator/Lobby Plan, SectionsDMLWaiting
Stair 1
101
Elev.Mach.Rm.
Lobby
Porch and ElevationsScale: 1/4" = 1'-0"
First Floor Plan
Scale: 1/4" = 1'-0"
Second Floor Plan
new window to match exist. size
Kawneer 451t series - thermal
break with temp. low-e insul. glass
or approved equal
Kawneer 451t series - thermal
break with low-e insul. glass
or approved equal
see Door Schedule
3'-6"Kawneer 451t series - thermal
break with temp. low-e insul. glass
or approved equal
Kawneer 451t series - thermal
break with low-e insul. glass
or approved equal
Kawneer 451t series - thermal
break with temp. low-e insul. glass
or approved equal
ELEVATOR SPECIFICATION
Traction Passenger Elevator (not hydraulic) complying with all national, state
and local codes, including all components necessary for a complete
installation. Provide a one-year warranty and one-year of regular maintenance
including examinations and adjustments, starting on the date that the
elevator and building are turned over to the owner.
3500 Pound
10'-0" floor to floor (verify)
Stretcher size capacity
Provide and elevator access control card reader
Power coated enamel finish entrances and doors
Brushed stainless steel cab front
High-pressure laminate wall panels
Mill finish aluminum sills
Brushed stainless steel handrails
Standard suspended ceiling
LED lighting
Laminate floor
Elevator manufacturer is to provide shop drawings showing all dimensions
and requirement for approval. Elevator shaft and machine room are to be
constructed per these shop drawings and the dimensions may vary from the
dimensions here. All components for a complete code compliant installation
are to be provided.
Consult structural engineering drawings for more information.
Contractor is to coordinate all dimensions and requirements prior to
construction.
Provide color charts for the owner and architect for finish selection4'-0"3'-4"4'-8"3'-4"existing dimensionsbacker rod and caulk at2"412"3"1'-412"3"212"3"3"4"
3"
8"5"system change - see
Kawneer 451T thermal break aluminum
2"x3" downspouts
3'-1"4'-3"2'-0"3"7"windows with low-e insulating glass
1 1/2" steel hat channels
5/8" gypsum board
3" StoTherm CI XPS system
2" StoTherm CI XPS system
3" StoTherm CI GPS system
See structural engineering drawings
for additional information
8" CMU
5/8" gypsum board
EIFS notes
fixed windows U= 0.45 maximum
exterior entrance door U= .63 maximum
SHGC .38 maximum
TYP. FOR ALL NEW ALUMINUM WINDOWS
coordinate rough openings prior to
masonry construction
3"10"6"6'-8"5"1'-2"3'-6"2'-8"3'-4"
3"3"4'-6"2'-8"8'-10"
Exterior Insulation and Finish System (EIFS) Specification
StoTherm CI GPS system above grade, above StoTherm GPS
3” GPS insulation at R-4.7 per inch = R-14.1 total
StoTherm CI XPS system below grade and up to the bottom of the
first trim band, 2'-1” above finish floor. Utilize Sto Flexyl
acrylic-based, fiber-reinforced, flexible adhesive and waterproofing
as waterproof adhesive and base coat.
Above finish floor - 3” XPS insulation at R-5.0 per inch = R-15.0
Below finish floor, on concrete foundation - 2” XPS insulation at
R-5.0 per inch = R-10.0
Sto Signature Stone 10 Finish
Two colors will be utilized
Provide color samples for owner and architect approval.
Provide installation details including wall/roof interface details
specifically for these conditions Sto Quik Finish System for concrete and CMU on this wall.040 pre-finished aluminum 3'-1"3"4'-0"3"3"4'-8"3"3"812"one-piece roof edge and gutter
3"212"3"3"1018"2"
1"
4"
alum. drip edge - to cover
unpainted side of gutter
(3) 2x4 p.t. blocking
steel deck
60 mil EPDM roofing
sloped insulation - 1/2" at edge, see roof plan for slopes
insulbase polyiso insulation
4.5" + 1" av. sloped insul = 5.5"
5.5" x R-5.7 per inch = R-31.3
Scale: 1/4" = 1'-0"
Rear Elevation
Scale: 1/4" = 1'-0"
Right Side Elevation
Scale: 1/4" = 1'-0"
Front Elevation
2'-812"2'-8"2'-812"
scored lines as shown
scored lines as shown
flashing painted to match wall color
STO EIFS system
Sto Signature Stone 10 Finish
two colors required
or approved equal
2"x3" downspouts
PAINTING SPECIFICATION
Paint entire building exterior as follows-
Clean walls and scrape loose paint. Fill cracks using appropriate
concrete and mortar repair compound or elastomeric patching
compound. Spot prime all repairs. Apply one coat Behr Acrylic
Interior/Exterior Multi-Surface Stain-Blocking Primer and Sealer or
Behr Interior/Exterior Metal Primer or other quality primers as
appropriate for substrate, followed by two coats Behr 'Dynasty'
premium acrylic exterior paint, or approved equal. Provide two full
paint color decks for architect and owner selections. Two exterior
colors will be required.
n e w c o n s t r u c t i o n
1"A-9
3
A-9
1
A-9
2
2"x3" downspouts
2"x3" downspouts
2"x3" downspouts
1" XPS at columns
Scale: 1/2" = 1'-0"
Wall Section
Scale: 1/4" = 1'-0"
Porch Section
Scale: 1/4" = 1'-0"
Cross Section
steel framing
Georgia Pacific DensGlass sheathing
1" GPS insulaton
STO EIFS system
STO EIFS system
Sto Signature Stone 10 Finish
two colors required
or approved equal
STO EIFS system
Sto Signature Stone 10 Finish
two colors required
or approved equal
7"11"7'-9"11"
1'-2"7'-6"1'-2"7'-512" (framing)10"1'-012"7"see structural engineering drawings
for additional information
see structural engineering drawings
for additional information
1 layer 5/8" firecode gypsum board
on 1 1/2" steel hat channels
1 layer 5/8" firecode gypsum board
on 1 1/2" steel hat channels
1 layer 5/8" firecode gypsum board
on 1 1/2" steel hat channels
2 layers 5/8" firecode
gypsum board on 1 1/2"
steel hat channels
2 layers 5/8" firecode
gypsum board on 1 1/2"
steel hat channels
1
2 310'-0" floor to floor (verify)9'-4"4'-412"9'-4"7"see structural engineering drawings
for additional information
Scale: 1/4" = 1'-0"
Roof Edge Detail
Carlisle SynTec fully adhered system,
Provide roofing and EIFS details, especially
wall/roof interface details prepared specifically for
these conditions. Mason is to install reglets in
CMU walls. Coordinate with roofing contractor.
or approved equal, 20 year warranty
A-9
3
All windows and doors are to be installed in strict accordance with
manufacturer's instructions, paying special attention to water
intrusion, including backer rod and caulking such as DOWSIL 795
silicone building sealant or other recommended premium caulking
materials suited for the particular application.
All window and door openings shown are nominal dimensions.
8"8'-6"8"
3"
1'-0"3"
9'-6"3'-8"8"6'-11"8"8'-9"8"7'-8"8"10"
3'-6"2'-8"3'-4"4'-2"1'-0"
3"2"1'-2"5'-4"1'-4"6'-8"this dimen. remains constant3"6'-5"3"NOTE - 3" offset remains constant !!!3"1'-4"6'-8"5'-2"2'-8"3'-8"8'-3"6'-8"3"2"10"7'-8"1'-0"1'-2"5"6'-8"5"1'-2"6'-11"8'-6"
3"
3"
8"3'-10"3'-2"3"3"per elev. manufacturer requirement3"812"3"812"2"x3" downspouts
2"x3" downspouts
2"x3" downspouts
2"x3" downspouts
3'-0" minimumflashing painted to match wall color
upper and lower downspouts to align exactly
24'-8" (could be up to 25'-4" depending on elevator manufaturer)Oct. 31, 202510/31/25 - added overall elevator and building height info22'-0" exist. height at front of tuilding, 21'-4" at rear of building (8" roof slope)