Loading...
HomeMy WebLinkAboutAP-2025-039 ElevationsDorm Stair 1 218 Elevator 2 Lobby 2007'-4" (finish)10"1'-2"4'-0"23'-812" (confirm dimensions with elevator mfgr.12'-7" to hoist beam (verify with mfgr.)Job Number269 South Main StreetDateDrawn ByRevisedc 2025(508) 612-8771Centerville, MA 02632High Point Treatment Center2510For High Point Treatment Center, Inc.60 Perseverance WayHyannis, MA 02601Bid Drawings - not for permitting or constructionNorthA-9Oct. 30, 2025Elevator/Lobby Plan, SectionsDMLWaiting Stair 1 101 Elev.Mach.Rm. Lobby Porch and ElevationsScale: 1/4" = 1'-0" First Floor Plan Scale: 1/4" = 1'-0" Second Floor Plan new window to match exist. size Kawneer 451t series - thermal break with temp. low-e insul. glass or approved equal Kawneer 451t series - thermal break with low-e insul. glass or approved equal see Door Schedule 3'-6"Kawneer 451t series - thermal break with temp. low-e insul. glass or approved equal Kawneer 451t series - thermal break with low-e insul. glass or approved equal Kawneer 451t series - thermal break with temp. low-e insul. glass or approved equal ELEVATOR SPECIFICATION Traction Passenger Elevator (not hydraulic) complying with all national, state and local codes, including all components necessary for a complete installation. Provide a one-year warranty and one-year of regular maintenance including examinations and adjustments, starting on the date that the elevator and building are turned over to the owner. 3500 Pound 10'-0" floor to floor (verify) Stretcher size capacity Provide and elevator access control card reader Power coated enamel finish entrances and doors Brushed stainless steel cab front High-pressure laminate wall panels Mill finish aluminum sills Brushed stainless steel handrails Standard suspended ceiling LED lighting Laminate floor Elevator manufacturer is to provide shop drawings showing all dimensions and requirement for approval. Elevator shaft and machine room are to be constructed per these shop drawings and the dimensions may vary from the dimensions here. All components for a complete code compliant installation are to be provided. Consult structural engineering drawings for more information. Contractor is to coordinate all dimensions and requirements prior to construction. Provide color charts for the owner and architect for finish selection4'-0"3'-4"4'-8"3'-4"existing dimensionsbacker rod and caulk at2"412"3"1'-412"3"212"3"3"4" 3" 8"5"system change - see Kawneer 451T thermal break aluminum 2"x3" downspouts 3'-1"4'-3"2'-0"3"7"windows with low-e insulating glass 1 1/2" steel hat channels 5/8" gypsum board 3" StoTherm CI XPS system 2" StoTherm CI XPS system 3" StoTherm CI GPS system See structural engineering drawings for additional information 8" CMU 5/8" gypsum board EIFS notes fixed windows U= 0.45 maximum exterior entrance door U= .63 maximum SHGC .38 maximum TYP. FOR ALL NEW ALUMINUM WINDOWS coordinate rough openings prior to masonry construction 3"10"6"6'-8"5"1'-2"3'-6"2'-8"3'-4" 3"3"4'-6"2'-8"8'-10" Exterior Insulation and Finish System (EIFS) Specification StoTherm CI GPS system above grade, above StoTherm GPS 3” GPS insulation at R-4.7 per inch = R-14.1 total StoTherm CI XPS system below grade and up to the bottom of the first trim band, 2'-1” above finish floor. Utilize Sto Flexyl acrylic-based, fiber-reinforced, flexible adhesive and waterproofing as waterproof adhesive and base coat. Above finish floor - 3” XPS insulation at R-5.0 per inch = R-15.0 Below finish floor, on concrete foundation - 2” XPS insulation at R-5.0 per inch = R-10.0 Sto Signature Stone 10 Finish Two colors will be utilized Provide color samples for owner and architect approval. Provide installation details including wall/roof interface details specifically for these conditions Sto Quik Finish System for concrete and CMU on this wall.040 pre-finished aluminum 3'-1"3"4'-0"3"3"4'-8"3"3"812"one-piece roof edge and gutter 3"212"3"3"1018"2" 1" 4" alum. drip edge - to cover unpainted side of gutter (3) 2x4 p.t. blocking steel deck 60 mil EPDM roofing sloped insulation - 1/2" at edge, see roof plan for slopes insulbase polyiso insulation 4.5" + 1" av. sloped insul = 5.5" 5.5" x R-5.7 per inch = R-31.3 Scale: 1/4" = 1'-0" Rear Elevation Scale: 1/4" = 1'-0" Right Side Elevation Scale: 1/4" = 1'-0" Front Elevation 2'-812"2'-8"2'-812" scored lines as shown scored lines as shown flashing painted to match wall color STO EIFS system Sto Signature Stone 10 Finish two colors required or approved equal 2"x3" downspouts PAINTING SPECIFICATION Paint entire building exterior as follows- Clean walls and scrape loose paint. Fill cracks using appropriate concrete and mortar repair compound or elastomeric patching compound. Spot prime all repairs. Apply one coat Behr Acrylic Interior/Exterior Multi-Surface Stain-Blocking Primer and Sealer or Behr Interior/Exterior Metal Primer or other quality primers as appropriate for substrate, followed by two coats Behr 'Dynasty' premium acrylic exterior paint, or approved equal. Provide two full paint color decks for architect and owner selections. Two exterior colors will be required. n e w c o n s t r u c t i o n 1"A-9 3 A-9 1 A-9 2 2"x3" downspouts 2"x3" downspouts 2"x3" downspouts 1" XPS at columns Scale: 1/2" = 1'-0" Wall Section Scale: 1/4" = 1'-0" Porch Section Scale: 1/4" = 1'-0" Cross Section steel framing Georgia Pacific DensGlass sheathing 1" GPS insulaton STO EIFS system STO EIFS system Sto Signature Stone 10 Finish two colors required or approved equal STO EIFS system Sto Signature Stone 10 Finish two colors required or approved equal 7"11"7'-9"11" 1'-2"7'-6"1'-2"7'-512" (framing)10"1'-012"7"see structural engineering drawings for additional information see structural engineering drawings for additional information 1 layer 5/8" firecode gypsum board on 1 1/2" steel hat channels 1 layer 5/8" firecode gypsum board on 1 1/2" steel hat channels 1 layer 5/8" firecode gypsum board on 1 1/2" steel hat channels 2 layers 5/8" firecode gypsum board on 1 1/2" steel hat channels 2 layers 5/8" firecode gypsum board on 1 1/2" steel hat channels 1 2 310'-0" floor to floor (verify)9'-4"4'-412"9'-4"7"see structural engineering drawings for additional information Scale: 1/4" = 1'-0" Roof Edge Detail Carlisle SynTec fully adhered system, Provide roofing and EIFS details, especially wall/roof interface details prepared specifically for these conditions. Mason is to install reglets in CMU walls. Coordinate with roofing contractor. or approved equal, 20 year warranty A-9 3 All windows and doors are to be installed in strict accordance with manufacturer's instructions, paying special attention to water intrusion, including backer rod and caulking such as DOWSIL 795 silicone building sealant or other recommended premium caulking materials suited for the particular application. All window and door openings shown are nominal dimensions. 8"8'-6"8" 3" 1'-0"3" 9'-6"3'-8"8"6'-11"8"8'-9"8"7'-8"8"10" 3'-6"2'-8"3'-4"4'-2"1'-0" 3"2"1'-2"5'-4"1'-4"6'-8"this dimen. remains constant3"6'-5"3"NOTE - 3" offset remains constant !!!3"1'-4"6'-8"5'-2"2'-8"3'-8"8'-3"6'-8"3"2"10"7'-8"1'-0"1'-2"5"6'-8"5"1'-2"6'-11"8'-6" 3" 3" 8"3'-10"3'-2"3"3"per elev. manufacturer requirement3"812"3"812"2"x3" downspouts 2"x3" downspouts 2"x3" downspouts 2"x3" downspouts 3'-0" minimumflashing painted to match wall color upper and lower downspouts to align exactly 24'-8" (could be up to 25'-4" depending on elevator manufaturer)Oct. 31, 202510/31/25 - added overall elevator and building height info22'-0" exist. height at front of tuilding, 21'-4" at rear of building (8" roof slope)