HomeMy WebLinkAboutAP-2025-039 Floor PlansJob Number269 South Main StreetDateDrawn ByRevisedc 2025(508) 612-8771Centerville, MA 02632High Point Treatment Center2510For High Point Treatment Center, Inc.60 Perseverance WayHyannis, MA 02601Bid Drawings - not for permitting or constructionK-4920-RBRANHAMC_URINALSVITREOUS CHINA K-4920-RBRANHAMC_URINALSVITREOUS CHINA Office Office Office Conference Office Office Office Sprinkler Waiting Office Group Room Restroom Cafeteria Reception Kitchen Elevator 1 Mach. Room Waiting Storage Vestibule Lobby Janitor Women's Restroom Men's Restroom K-12643GREENWICHC_LAVATORYVITREOUS CHINA 100'-0"warewasher ice maker TUC-72 undercounter refrigerator dish table soil dishtable two compartment sink work tablework tablework table work table HF-E-120 hot food tabletable three sink hand sink 8' x 16' work table hand sink work tables A-1Oct. 30, 2025First Floor Planwork exhaust hood table work table work Pantry A-7 1 Stair 3 Stair 1 compartment 101102 Scale: 1/8" = 1'-0" First Floor Plan Corridor 103 104105106107108109110 Electrical 148 Corridor 111 114 Kitchen 112 Walk-In Cooler/Freezer 113 Corridor 115 Closet 116 Closet 117 118 Office 119 Office 120 Office 121 Closet 122 129 Office 128 Corridor 130 133 Office 143 Office 131 136 138 132 Corridor 134 IT 137 Office 123 Office 124 Office 126 125 127 Reception 140 139 142 141 Corridor 145 144 147 Elect. 149 146 Stair 2 no work this area no work this area n o w o r k t h i s a r e a Closet 135 Elev.Mach.Rm.NorthLobby 100 Porch 101 101a 102 100100a 100b 150 104105106 107 108109110 148 111 150144 141 141a 139 140 143142 134 146 145 147 111a 149 138 136 135 116 117 133 133a 112 114 112a 118 129 129a 130a 119 120 121 122 123124125126 128 130 134a 132 131 127 139a no work this area DMLgas range convection oven steamer Elevator 2 167'-4" 137 Utility 138a 138a water htrs. this area can be used for construction material storage See 1/4" = 1'-0" scale Drawing A-9 remove two - 36" section of cabinets install new sidesplash and plastic laminate 18" 42"6"42"12"42"6"12"42"18"gyp. board wallsee Drawing A-7new partial8,073 SF not including Lobby, central Corridor, 'no work this area' spaces, and not including Elevator 1 and Machine Room See Site Engineering Drawings for paving and parking informationKitchen equipment is to be supplied by the owner and coordinated and installed by the contractor, including steam tables in serving areas. Owner's kitchen supplier or suppliers are to review and confirm all requirements and code issues prior to construction. Kitchen exhaust hood is to be supplied by the owner and installed by the contractor. Kitchen exhaust ducts, materials and installation, are to be provided and installed by the general contractor / subcontractors. 15'-1012"3'-6"6'-0"8'-8"11'-5"5'-912"2'-812"8'-312"6'-0"6' - 0 " 6 "6"coordinate size prior to framing Pantry 12" clear 2'-3" 4'-9"4'-10316"6'-0"2'-33 4" 2'-712" 5'-9"5'-712"11'-10"11'-0"4'-3"1'-412"414"3'-214"5'-0"3'-214"414"1'-412"4'-3"8'-6"14'-4" LIST OF ARCHITECTURAL DRAWINGS A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 A-10 First Floor Plan Second Floor Plan First Floor Reflected Ceiling Plan Second Floor Reflected Ceiling Plan Roof Plan Door and Finish Schedule Cross Section and Details Restroom Plans and Elevations Lobby and Elevator Plans and Details Demolition Plan two rolling counter shutters see detail Drawing A-7 48" medical cab.48" medical cab. Medical cabinets are to be Universal Medical 'Clinton' wall and base cabinet units with Universal Medical stainless steel sink and gooseneck faucet, or approved equal. Two 48" units are required on the First Floor and one 42" unit with field fitted fillers, side and backspashes and one 48" unit are required on the Second Floor, as noted on the floor plans1'-914"914"3'-6"914"new sheet metal hoods over existing windows - see Roof Plan sliding window - see elev. on A-7repair exist. windowWALL TYPES Walls are generally to be 3 5/8" metal studs with 5/8" gypsum board each side, 8'-0" high unless noted otherwise. F indicates full height walls, 3 5/8" metal studs with 5/8" gypsum board each side and 3 1/2" fiberglass insulation. S indicates Smoke Partitions Construction shall be 3 5/8" metal studs with 5/8" gypsum board each side with 3 1/2" fiberglass insulation. Smoke Partitions shall extend from the floor slab to the underside of the floor or roof deck above. Smoke partitions do not require a fire rating, but are to be fitted to prevent the free passage of smoke. Doors in smoke partitions do not require a fire rating and do not require door closers. Louvers are not permitted in smoke partitions or doors. 1 indicates 1-hour rated wall full height wall - 3 5/8" 20 gauge steel studs with 5/8" firecode gypsum board each side, constructed per UL Des U423 Gypsum board can be 1/2" to match existing construction, if needed, in non-fire rated wall assemblies. 1 1 1 F F F F1 F F F F F F F F FF F 6" stud wall F F F F F F F F F F F FF F F F F F F F F F F F F repair existing gypsum board wherever required F F 1'-8" GENERAL NOTES All work is to comply with all applicable Codes, Ordinances, Regulation and responsible trade practices. Contractors and Subcontractors are to review all applicable field conditions and requirements prior to bid. Pricing is to include all work shown, noted, or required for complete code compliant systems installed in accordance with manufacturer's instructions and responsible trade practices. ABC fire extinguisher ABC fire extinguisher class K fire extinguisher ABC fire extinguisher ABC fire extinguisher 6'-7"10'-2"1'-10"9'-6"6'-912"this wall is to mirror opposite side 8'-4"6'-0"2'-1012"2'-8"F F 7'-912" new toilet partitions and counters per MAAB req. see finish schedule and engineering drawings new toilet partitions and counters per MAAB req. see finish schedule and engineering drawings 10'-314"10'-314"6'-0" 3'-5"7'-714"4'-9"4'-1034"up up up Van Accessible parking space van accessible signage installed in accordance with MAAB 23.6 8'-0"8'-0"+/- 9'-4"18'-0" new conc. sidewalk conc. sidewalk conc. sidewalk new landscaping not in contractnew landscaping not in contractnew landscaping NICremove exist. paving 1:20 max. slope6" h. step4'-6"4'-0"remove exist. paving to this lineNew sidewalks are to be 5" thick, 4000 PSI min. air entrained concrete with 6x6 W1.4 x W1.4 welded wire mesh at mid depth. on 8" dense graded crushed stone base over compacted suitable subgrade. 2 toilets to be moved as shown The interiors of any existing exterior walls, including existing walls above suspended ceilings shall be repaired and/or completed, including studs if needed, insulation to match existing and gypsum board. Gypsum board that will be concealed can be LEVEL 1 finish with taped joints embedded in joint compound. Excess joint compound and tool marks are acceptable, no paint requried. Job Number269 South Main StreetDateDrawn ByRevisedc 2025(508) 612-8771Centerville, MA 02632High Point Treatment Center2510For High Point Treatment Center, Inc.60 Perseverance WayHyannis, MA 02601Bid Drawings - not for permitting or constructionDorm Dorm Group Room Office Office Office Manager OfficeStorage Office Office Nurse StationSitting / Dining Exam Room Office OfficeITElectrical Office Office Office Office Office Sitting / Dining Men's Restroom Office Sitting Area Laundry Meds Women's Restroom Men's Restroom Laundry Serving Restroom Intake Exam Nurse Station Meds. Serving Women's Restroom K-12643GREENWICHC_LAVATORYVITREOUS CHINA Accessible RR100'-0"NorthA-2Oct. 30, 2025Second Floor PlanDMLskylight skylight skylight skylight skylight location of hood (below) shown dashed Jan. A-7 1 Stair 3 Elevator 1 Corridor 253 254 252 Dorm 251 Dorm 250 Dorm 249 Dorm 248 Scale: 1/8" = 1'-0" Storage Stair 2 Lobby 235 Corridor 201 202203204205206207208209 washer dryer washer dryer 210 211 212 213 214 215 216 217 219 Dorm 220 Dorm 221 Dorm 222 Dorm 223 Dorm 224 Dorm 225 226 Corridor 227 228 230 Vestibule 229 231 232 Corridor 236 Shower 238 Shower 240 Shower 241 Shower 242 Restroom 233 Vestibule 239 243 244 Corridor 245 237 246 247 255 256 Dorm 257 Dorm 258 Dorm 259 Dorm 260 Dorm 261 262 264 Corridor 263 265 266 267 268 269 270 271 272 273 274 275 234 254a 203204205206207208209210 236 211 212 212a 215 214 218213 219 220 221 222 223 224225 234 226 228 227 231 232 230 216 244 243 240 241 242 233 238 254 253 252 251 250 249 248 246 256 257 258 259 260 261 262 264 265 266 267 268 263a 269 270 271 272 273 274 263 275 276 235 247 246a Dorm Stair 1 218 Elevator 2 Lobby 200 5'-0"7"7'-712"5'-412"6'-0"24'-0"5'-612"2'-0"8'-1112"1112"9'-1"9'-8"9'-11"9'-1112"5'-812"5'-112"5'-10"1'-0"24'-0"6'-0"7'-712"10'-0"10'-0"10'-0"5'-112" 202 Dorm 167'-4" 200a 200 237 Jan. 276 K-12643GREENWICHC_LAVATORYVITREOUS CHINAwasherdryerEmployee Second Floor Plan 31'-0"11'-4"9'-4"11'-4"8'-8" Five new windows, see Drawing A-7. Window locations can be modified slightly to align with vertical CMU joints. See 1/4" = 1'-0" scale Drawing A-9 See 1/4" 1'-0" scale Drawing A-8 See 1/4" 1'-0" scale Drawing A-8 K-12643GREENWICHC_LAVATORYVITREOUS CHINA 211a Restroom 211a S F F F F F S F S S S S S S S F F F F S F S S S S S F 16,608 SF A-7 2 wall is to replace exist. wall this location relocated windowexist. windowsliding windows - see note on A-7 6'-0"5'-2"1'-8" plas. lam. covered counter10'-0"3'-312"3'-3"1 1 1 1 1 1 6" studs F S S S F F F S S S S S S S F F F F F S 1 1 1 FFF 9'-912"10'-0"10'-0"9'-912" FS F F S S 23'-1112" 21'-0"11'-1134"12'-212"12'-214"12'-1"9'-3"2'-10"2'-2"5'-0"8'-73 4"8'-73 4"6'-0"21'-0" See Drawing A-8 for dimensions this area 3'-1"4'-0"7"4'-0"412"rolling counter shutter see detail Drawing A-7 4'-6"rolling counter shutterssee detail Drawing A-742" medical cab. 48" medical cab. 3'-7"4'-012"three sliding windows see note on A-7 repair existing gypsum board wherever required1'-8"1'-8" WALL TYPES Walls are generally to be 3 5/8" metal studs with 5/8" gypsum board each side, 8'-0" high unless noted otherwise. F indicates full height walls, 3 5/8" metal studs with 5/8" gypsum board each side and 3 1/2" fiberglass insulation. S indicates Smoke Partitions Construction shall be 3 5/8" metal studs with 5/8" gypsum board each side with 3 1/2" fiberglass insulation. Smoke Partitions shall extend from the floor slab to the underside of the floor or roof deck above. Smoke partitions do not require a fire rating, but are to be fitted to prevent the free passage of smoke. Doors in smoke partitions do not require a fire rating and do not require door closers. Louvers are not permitted in smoke partitions or doors. 1 indicates 1-hour rated wall full height wall - 3 5/8" 20 gauge steel studs with 5/8" firecode gypsum board each side, constructed per UL Des U423 Gypsum board can be 1/2" to match existing construction, if needed, in non-fire rated wall assemblies. GENERAL NOTES All work is to comply with all applicable Codes, Ordinances, Regulation and responsible trade practices. Contractors and Subcontractors are to review all applicable field conditions and requirements prior to bid. Pricing is to include all work shown, noted, or required for complete code compliant systems installed in accordance with manufacturer's instructions and responsible trade practices. BUILDING CODE INFORMATION Applicable Building Codes Massachusetts Building Code, 10th/ Edition, based on IBC 2021 Massachusetts Existing Building Code 2021, based on EIBC 2021 Massachusetts Architectural Access Board Regulations, 521 CMR, 2006 Edition Massachusetts Commercial Energy Code 2019 - Effective dates July 1, 2023 - Present Massachusetts Fire Code 2021 Massachusetts Mechanical Code 2021 Existing Building First Floor - B Business Second Floor - B Business and Institutional Group I-1 Proposed Uses First Floor - B Business Second Floor - Institutional Group I-2 308.3 Institutional Group I-2 Institutional Group I-2 occupancy shall include buildings and structures used for medical care on a 24-hour basis for more than five persons who are incapable of self-preservation. This group shall include, but not be limited to, the following: Detoxification facilities 308.3.1.2 Condition 2 This occupancy condition shall include facilities that provide nursing and medical care and could provide emergency care, surgery, obstetrics or in-patient stabilization units for psychiatric or detoxification, including but not limited to hospitals. Building Area First Floor - 17,054 SF + 332 SF Lobby/Elevator addition = 17,386 SF First Floor renovated area - 8,073 SF Second Floor - 16,409 SF + 186 SF addition = 16,595 SF Total Building Area - 33,981 SF Per Table 506.2d Institutional Group I-2 30,000 SF per floor allowable prior to area increase allowances. Per Table 601 Type IIIB construction Two-hour rated exterior bearing walls, noncombustible, no ratings for floor, roof or interior supports 407.3 Corridor Wall Construction Corridor walls (second floor) shall be constructed as smoke partitions in accordance with Section 710. 1010.2.14 Controlled Egress Doors in Groups I-1 and I-2 Electric locking systems, including electro-mechanical locking systems and electromagnetic locking systems, shall be permitted to be locked in the means of egress in Group I-1 or I-2 occupancies where the clinical needs of persons receiving care require their containment. Controlled egress doors shall be permitted in such occupancies where the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or an approved automatic smoke detection system installed in accordance with Section 907, provided that the doors are installed and operate in accordance with all of the following: The door locks shall unlock on actuation of the automatic sprinkler system or automatic smoke detection system. The door locks shall unlock on loss of power controlling the lock or lock mechanism. The door locking system shall be installed to have the capability of being unlocked by a switch located at the fire command center, a nursing station or other approved location. The switch shall directly break power to the lock. A building occupant shall not be required to pass through more than one door equipped with a controlled egress locking system before entering an exit. The procedures for unlocking the doors shall be described and approved as part of the emergency planning and preparedness required by Chapter 4 of the International Fire Code. All clinical staff shall have the keys, codes or other means necessary to operate the locking systems. Emergency lighting shall be provided at the door. The door locking system units shall be listed in accordance with UL 294. ABC fire extinguisher ABC fire extinguisher ABC fire extinguisher ABC fire extinguisher ABC fire extinguisher ABC fire extinguisher ABC fire extinguisher S S S S S S S S S S S S S S S S S S SSS S SS S S S S S S F 3'-0" min.1'-7"4'-10" min.22" min.F F F F 7'-2" F F F F down down down S see plumbing dwgs.S S S S S S F S S S S S S SS The interiors of any existing exterior walls, including existing walls above suspended ceilings shall be repaired and/or completed, including studs if needed, insulation to match existing and gypsum board. Gypsum board that will be concealed can be LEVEL 1 finish with taped joints embedded in joint compound. Excess joint compound and tool marks are acceptable, no paint requried. S new ducts in exist. chase see HVAC dwgs. new ducts in exist. chase see HVAC dwgs. see kitchen duct wrap note on A-8