Loading...
HomeMy WebLinkAboutAP-2026-001 Revised Elevations 16'-8"7'-8" V.I.F. 7'-7" 8'-11"7'-0"6'-8" 14'-11 2" 7'-7"8'-2"EXISTINGBATHNEWBATHGAMEROOMEXISTING CEILINGAT 7'-7"MAINTAIN 6'-8"MINIMUM CLEARNEW ROOFFRAMING OVERCONNECTORNEW STAIRS, 4RISERS TOMATCH EXISTINGFIRST FLOOR2"1'-0"R20'-414"1'-4"2'-4"EXISTINGGARAGEDOUBLE 2 X 12HEADER2 X 6 FRAMING AT 16"O.C. OVERFRAMEEXTEND WALL UP2 X 12 RIDGE2 X 4 AT 16" O.C.COLLAR TIESVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTIONVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 8" THICKFOUNDATION WALLEXISTINGSTORAGE7" STEP AT STORAGEEXISTING 2 X 6 FRAMING TO REMAINEXISTING 2 X 6 FRAMING TO REMAINVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 6" THICKFOUNDATION WALL4'-4"PROVIDE R 49INSULATION AT CEILINGJOISTS OR EQUALPROVIDE SOLIDBLOCKING .VERIFY EXISTINGFRAMINGNEW CONSTRUCTION 2 X 6 AT 12" FAUXFRAMING FORARCHED CEILING7'-8" 7'-8"7'-7" 6'-111 4" 14'-01 2" 7'-7"EAVE, GUTTER, ANDSOFFIT DETAIL TOMATCH EXISTING2 X 6 EXTERIOR WALLBUILT-IN 2 DRAWERLATERAL FILE CABINETSWITH WOOD TOPARCH VAULTED WOODCEILINGEXISTING FAMILY ROOM- NEW CEILING, PATCHAND REPAIR WALLS ASREQUIREDEXISTING GARAGEEXISTING FOUNDATIONWALLS TO REMAINGAMEROOM1'-512"1'-512"7'-0"1'-0"1'-4"EXISTINGGARAGE2 X 12 FLOOR FRAMINGEXISTING 2 X 8 FLOORFRAMINGEXISTING 2 X 6EXTERIOR WALLASSUMED 8" THICKCONCRETEFOUNDATION WALLAT GARAGEEXISTING 2 X 6EXTERIOR WALL2 X 12 RIDGE2 X 4 AT 16" O.C.COLLAR TIESVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 8" THICKFOUNDATION WALLVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 6" THICKFOUNDATION WALLEXISTINGBASEMENTEXISTINGSTORAGEEXISTINGKITCHENEXISTINGFAMILYPROVIDE R 49 INSULATIONAT CEILING JOISTS OREQUALNEW CONSTRUCTION 7'-8"7'-8"8'-11"14'-012"7'-7"EAVE AND SOFFIT DETAILTO MATCH EXISTINGVERIFY HEIGHTS FORWINDOW TO MATCHEXISTINGNEW BAY WINDOW TOALIGN WITH EXISTINGBAY WINDOWARCH VAULTED WOODCEILINGEXISTING FAMILY ROOM- NEW CEILING, PATCHAND REPAIR WALLS ASREQUIREDEXISTING GARAGE DOORGAMEROOM2'-6"EXISTING BAY WINDOWEXISTING 2 X 8FLOOR FRAMINGEXISTINGGARAGEASSUMED 8" THICKCONCRETEFOUNDATION WALLAT GARAGEEXISTING 2 X 6EXTERIOR WALLEXISTING 4" X 12"STEEL BEAM6'-814" +/-2 X 6 EXTERIOR WALLEXISTING BRACKETS ATBAY WINDOW TO BEREVIEWEDVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 6" THICKFOUNDATION WALLVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 6" THICKFOUNDATION WALLVERIFY EXISTING FOUNDATIONWIDTH AND FOOTING WIDTH ANDDEPTH PRIOR TO CONSTRUCTION.APPEARS TO BE 8" THICKFOUNDATION WALLWIND BLOCKING TYPICALLEVEL 2 BAYS AT 4'-0" O.C.WIND BLOCKING TYPICALLEVEL 2 BAYS AT 4'-0" O.C.WIND BLOCKING TYPICALLEVEL 2 BAYS AT 4'-0" O.C.4'-10" V.I.F.4'-0"OPENING FOR CIRCULARSTAIR. COORDINATEWITH FINAL SELECTION3'-0"NEW CONSTRUCTIONEXISTING WOODDECK AND STAIRSREBUILT HEADER ATGARAGE DOOR - DOUBLE11 78" MINIMUM LVL5'-812" +/-2 X 6 CEILINGJOISTS AT 16 O.C.2 X 6 FAUXFRAMING AT 12"O.C. FORARCHED CEILINGNEW DORMERLINE OF EXISTING ROOF7'-7" V.I.F.APPROX. LINE OF EXISTINGKNEE WALLAPPROX. LINE OF EXISTINGSLOPED CEILINGEXISTING 2 X 10 FLOORSTRUCTURE - V.I.F.EXISTING EXTERIOR WALLEXISTING MAIN HOUSEFIRST FLOOR FRAMINGEXISTING BASEMENT WALLTO BE VERIFIEDALIGN NEW CEILING WITHEXISTING FLAT CEILING INBEDROOM. TOP PLATEAPPROXIMATELY 7'-8 14"ALIGN NEW DORMERWITH EXISTING WALL7'-81 4" +/- PLATE 14'-3"2 X 12 RIDGE BOARD2 X 6 COLLAR TIES AT16" O.C.FULL HEIGHT STUDS2 X 8 CEILING JOISTS AT16" O.C. TO ALIGN WITHEXISTINGALIGN RIDGE WITHEXISTING RIDGECONSULTANT LOGO:CERTIFICATION :THIS DRAWING IS A PART OF AN INTEGRATED SET OFCONSTRUCTION CONTRACT DOCUMENTS. REFER TOALL DRAWINGS AND SPECIFICATIONS INCLUDING BUTNOT LIMITED TO "GENERAL CONDITIONS", "SUMMARYOF WORK" AND ANY APPLICABLE MANUFACTURERSTECHNICAL SPECIFICATIONS.REFER TO ALL OF THE DRAWINGS FOR COMPLETESCOPE OF WORK.THIS DRAWING IS NOT TO BE SCALED AND/OR USEDAS AN AS-BUILT.REVISIONSDESCRIPTIONDATENo.PROJECT NAME:43 Fieldstone CircleARCHITECTURAL DESIGNJACQUESMiddleboro, MA 02346SHEET TITLE:Phone: 508-320-3850JOB NUMBER:DATE ISSUED:CHECKED BY:DRAWN BY:SCALE:SHEET NUMBER:JOHNWAYNEBUILDING SECTIONSGENERAL NOTES202512WJJWJJAS NOTEDA4.1ISSUED FOR SUBMISSION - DATE: 11/16/2025NOVEMBER 16, 2025LITTLETON RESIDENCE23 HAYWARD ROADBARNSTABLE, MA0102W A Y NEJOHNJACQUESNO. 06935BOSTONMACOMMONWEALTHOFMASSACH U SETTS