HomeMy WebLinkAboutAP-2026-003 Copacabana Realty Investment Inc - Elevations and Floor PlansScale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comPROJECT SCOPE:CHANGE OF USE AND INTERIOR RENOVATIONVERIFY IN FIELD (V.I.F.)ALL DIMENSIONSINTERIOR RENOVATION11 POTTER AVE.11 POTTER AVE.HYANNIS, MA 02601HYANNIS, MA 02601DESIGN DEVELOPMENT01/13/2026A00001/13/2026HYAN-11PADESIGNDEVELOPMENTCOVER SHEET1- ALL WORK SHALL COMPLY WITH STATE AND LOCAL BUILDING CODES AND REGULATIONS2- CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, AND PROCEDURES.3- CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS DURING BUILDING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING AND BRACING TO ENSURE SUCH SAFETY.4- ALL DIMENSIONS AND SITE CONDITIONS SHALL BE FIELD VERIFIED AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. NOTIFY THE OWNER OR DESIGNER OF ANY DISCREPANCY PRIOR TO COMMENCEMENT OF WORK.5- IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, AND TO PROTECT THEM FROM DAMAGE.6- ALL DETAILS, SECTIONS, NOTES, OR REFERENCE TO OTHER DRAWINGS ARE INTENDED TO BE TYPICAL. 7- DURING CONSTRUCTION, AND PRIOR TO THE INCORPORATION OF ANY CHANGES, REVISIONS, MODIFICATIONS OR DEVIATION FROM THE CONSTRUCTION DOCUMENT, CONTRACTOR SHALL BRING TO THE ATTENTION OF THE OWNER OR DESIGNER AND OBTAIN APPROVAL FROM THE BUILDING INSPECTOR BEFORE PROCEEDING WITH THE WORK.8- SPECIFIC NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT.9- GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION.10-CONTRACTOR SHALL PERFORM ALL WORKS IN COMPLIANCE:A- Building: INTERNATIONAL RESIDENTIAL CODE (IRC) 2021 WITH ALL MA AMENDMENTS. Any reference in 780 CMR to the International Residential Code shall be considered reference to 780 CMR 51.00 through 120.00.B- Architectural Access:MASSACHUSETTS ARCHITECTURAL ACCESS BOARD 521-CMR AND THE AMERICANS WITH DISABILITIES ACT (ADAAG), WHERE REQUIRED.C- Mechanical:INTERNATIONAL MECHANICAL CODE (IMC) 2015 WITH 780 CMR - MA MECHANICAL AMENDMENTS.D- Electrical:527 CMR 12.00 (2015 NATIONAL ELECTRICAL CODE) Any reference in 780 CMR to the International Electrical Code shall be considered reference to 527 CMR 12.00: Massachusetts Electrical Code (Amendments).E- Plumbing: 248 CMR MASSACHUSETTS PLUMBING REGULATIONS Reference to the International Plumbing Code shall be considered reference to 248 CMR: Board of State Examiners of Plumbers and Gas Fitters.F- Fire Prevention: INTERNATIONAL FIRE CODE (IFC) AND INTERNATIONALMECHANICAL CODE (IMC) 2015 WITH 527 CMR REGULATIONSAND 780 CMR MA CODE AMENDMENTSG-Energy: 2021 IECC with MA AMENDMENTS."PROJECT LOCATIONGENERAL NOTESSHEET LIST# SHEET NAMEA000 COVER SHEETA001 NOTESA100 EXISTING GARAGE FLOOR PLANA101 GARAGE DEMOLITION PLANA102 PROPOSED GARAGE FLOOR PLANA103 PROPOSED 1ST FLOOR PLANA200 EXISTING FRONT ELEVATIONA201 FRONT DEMOLITION ELEVATIONA202 PROPOSED FRONT ELEVATIONA203 EXISTING LEFT SIDE ELEVATIONA204 DEMOLITION LEFT SIDE ELEVATIONA205 PROPOSED LEFT SIDE ELEVATIONA206 EXISTING REAR ELEVATIONA207 DEMOLITION REAR ELEVATIONA208 PROPOSED REAR ELEVATIONA209 EXISTING RIGHT SIDE ELEVATIONA210 DEMOLITION RIGHT SIDE ELEVATIONA211 PROPOSED RIGHT SIDE ELEVATIONAPPLICABLE BUILDING CODESTHE FOLLOWING PLANS WERE PREPARED IN ACCORDANCE WITH THE FOLLOWING APPLICABLE CODES:BUILDING CODE: 2021 INTERNATIONAL EXISTING BUILDING CODE WITH MASSACHUSETTS AMENDMENTS - 10TH EDITIONPLUMGINB CODE: 248 CMR 10.00: UNIFORM STATE PLUMBING CODEMECHANICAL CODE: 2021 INTERNATIONAL MECHANICAL CODE WITH MASSACHUSETTS AMENDMENTS - 9TH EDITIONELECTRICAL CODE: 2021 NFPA 70 (527CMR 12.00 STATE ELECTRICAL CODEACCESSIBILITY CODE: 521 CMR - THE RULES AND REGULATIONS OF THE ARCHITECTURAL ACCESS BOARDPROJECT NARRATIVE:This project involves alterations LEVEL 2to an existing building. There will be a change of use from Group B to Residential R2.Construction Type 5A. The unit is a 2-story building that will be GROUP R2. Work includes repair interior partitions with Life Safety devices to accommodate the new design, new 1-hour Fire Rated walls and ceiling between units. Proposed plans are 4 Residential Units, being 2 Units in the First Floor and 2 Units on the Second Floor.THE FOLLOWING PLANS WERE PREPARED IN ACCORDANCE WITH THE FOLLOWING APPLICABLE CODES:BUILDING CODE: 2021 INTERNATIONAL EXISTING BUILDING CODE with MASSACHUSETTS AMENDMENTS- 9TH EDITION.PLUMBING CODE: 248CMR10.00: UNIFORM STATE PLUMBING CODE.MECHANICAL CODE: 2021 INTERNATIONAL MECHANICAL CODE with MASSACHUSETTS AMENDMENTS - 9TH EDITION AND 780CMRELECTRICAL CODE: 2023NFPA70 (527CMR12.00 STATE ELECTRICAL CODE.ENERGY CODE: 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC).ACCESSIBILITY CODE: 521CMR- THE RULES AND REGULATIONS OF THE ARCHITECTURAL ACCESS BOARD.CONSTRUCTION SCOPE OF WORK:· INTERIOR RENOVATION OF PARTITIONS TO ACCOMODATE TWO NEW RESIDENTIAL UNITS ON THE 1ST FLOOR AND TWO NEW RESIDENTIAL UNITS ON THE SECOND FLOOR.· NEW 1-HOUR FIRE RATED WALL AND CEILING TO BE PROVIDED BETWEEN UNITS AND COMMON AREAS.·CHANGE OF USE, FROM GROUP B TO GROUP R2. BUILDING IS 5.382,00 S.F.· NEW SPRINKLER SYSTEM TO BE INSTALLED. PROJECT BY OTHERS.· BUILDING IS TYPE III EXIT TRAVEL DISTANCE IS 200'PER TABLE 1017.2ZONING: RBCONSTRUCTION TYPE:602.3 TYPE 5ALEVEL OF ALTERATION:CHAPTER 8 ALTERATIONS -LEVEL 02FIRE PROTECTION:EXISTING FIRE ALARM AND DETECTION SYSTEM TO BE UPDATED AS NEEDED AND NEW SPRINKLER SYSTEM TO BE INSTALLED.OCCUPANCY:310.4 RESIDENTIAL GROUP R2.
THE DRAWING REPRESENT CONSTRUCTION IN SCALE BUT DO NOT "SCALE" DRAWINGS TO OBTAIN MISSING INFORMATION OR TO INTERPRET ANY INFORMATION NOT SPECIFICALLY DIMENSIONED FOR EXACT DETAILING, FABRICATION OR CONSTRUCTION PURPOSES. CONTACT THE DESIGNENGINEER FOR ANY REQUIRED MISSING DIMENSIONS.THE CONTRACTOR SHALL OBTAIN ALL PERMITS FROM THE BUILDING DEPARTMENT PRIOR TO THE START OF WORK.THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK. VERIFY AND CONFIRM ALL DIMENSIONS,ELEVATIONS AND LOCATIONS OF EXISTING BUILDINGS AND OTHER STRUCTURES PRIOR COMMENCING THE WORK. DISCREPANCIES SHALL BE REPORTED TO THE DESIGN ENGINEER IMMEDIATELY, BEFORE PROCEEDING.THE CONTRACTOR ARE RESPONSIBLE FOR ACCURATE COORDINATION OF ALL RELATED PROJECT DRAWINGS, INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, STRUCTURAL, CIVIL AND UTILITIES DRAWINGS. THECONTRACTOR SHALL VERIFY ALL DETAILS, DIMENSIONS AND SYSTEMS PRIOR WORK OR ORDERING ANY ITEM AND COORDINATE WITH THE ARCHITECT OR THE RELATED ENGINEER. DO NOT COMMENCE WORK UNTIL CONDITION IS RESOLVED AND MODIFICATION IF NEEDED ISAPPROVED. ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES THAT MAY EXIST PRIOR TO COMMENCING THE WORK.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING REQUIRED FOR PLUMPNESS, STRUCTURAL STABILITY ANDSAFETY WHENEVER REQUIRED TO SUPPORT LOADS AS MAY BE IMPOSED UPON THE STRUCTURE AND ITS COMPONENTS DURING CONSTRUCTION.THE CONTRACTOR SHALL BE COMPLETELY RESPONSIBLE FOR THE SAFETY OF ADJACENT STRUCTURES, PROPERTY, HIS WORKMEN, AND THE PUBLIC, AS AFFECTED BY THE CONSTRUCTION OF THIS PROJECT.THESE DRAWINGS ARE INTENDED TO BE USED ONLY BY EXPERIENCED CONTRACTOR WITH KNOWLEDGE ON THIS TYPE OF WORK. SOULVE PLUS PERSONNEL ARE AVAILABLE TO ANSWER QUESTIONS AND ASSIST THE CONTRACTOR BY EXPLAINING THE DESIGN INTENT.CONTRACTOR SHALL UNDERSTAND THE COMPLEXITIES OF THE PROJECT AND THE CONSTRUCTION SEQUENCE . THE CONTRACTOR ASSUMES TOTAL RESPONSIBILITY FOR ANY CONSEQUENCE OF THAT ACTION.KEY NOTE:GENERAL MECHANICAL / HVAC NOTESCONTRACTOR TO COORDINATE ALL MECHANICAL DUCTWORK WITH OWNER AND ARCHITECT.PROVIDE CODE SPECIFIED FRESH AIR INTAKE PER PERSON TO ALL OCCUPIED SPACES.SEE SPECIFICATIONS FOR ADDITIONAL MECHANICAL / HVAC REQUIREMENTS.GENERAL PLUMBING NOTESPROVIDE ROUGH PLUMBING, FINISH PLUMBING AND FIXTURES AS SHOWN ON DRAWINGS.ALL PIPING SHALL BE CONCEALED IN WALLS, FLOORS, CEILINGS OR PIPE CHASES.PROVIDE ESCUTCHEONS AT PIPING PENETRATIONS THROUGH WALLS.PROVIDE FROST-PROOF HOSE BIBS WHERE INDICATED.SEE SPECIFICATIONS FOR ADDITIONAL PLUMBING REQUIREMENTS.GENERAL ELECTRICAL NOTESPROVIDE COMPLETE ELECTRIC PANELBOARD WITH TRIM - SIZE OF PANEL BOARD AS NOTED INSPECIFICATIONS. CONTRACTOR TO LOCATE ELECTRICAL SERVICES AND METERS AS SHOWN ONDRAWINGS.REFER TO MOUNTING HEIGHT SCHEDULE FOR HEIGHTS OF ELECTRICAL COMPONENTS.INSTALLATION OF OUTLET BOXES BACK TO BACK IS NOT PERMITTED.ALL WIRING SHALL BE CONCEALED IN ALL FINISHED AREAS.PROVIDE ALL GROUNDING INCLUDING GREEN EQUIPMENT.CONTRACTOR SHALL PROVIDE ALL NECESSARY FIXTURE ACCESSORIES.CONTRACTOR IS RESPONSIBLE FOR OBTAINING NECESSARY PERMITS AND INSPECTIONS.MAINTAIN CORRECT PHASING SEQUENCE OF ALL FEEDERS AND CIRCUITS BY ESTABLISHEDPHASE IDENTIFICATION AND MAINTAIN CORRECT RELATIONSHIP THROUGHOUT THE SYSTEM.PROVIDE LINE BALANCE WITHIN 10% OF NORMAL LOADS.SUPPORT INSULATED CONDUCTOR WIRE EVERY 4 FEET AND WITHIN 1 FOOT OF ALL BOXES.PROVIDE OUTLET BOX SUPPORT BRACKETS, COUPLINGS AND CONNECTORS WITH STEEL SETSCREWS - DIE CAST FITTINGS ARE NOT ACCEPTABLE.IN ADDITION TO ALL DEDICATED CIRCUITS REQUIRED BY CODE, PROVIDE DEDICATED 20 AMPCIRCUIT FOR REFRIGERATOR LOCATIONS AS INDICATED ON DRAWINGS.COORDINATE POWER REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT.ALL CABLE TELEVISION AND TELEPHONE ROUTING SHALL BE MADE WITH HOMERUNS, WIRED(CABLED) FROM ONE CENTRAL LOCATION ON THE OUTSIDE OF THE HOME (5 FT. MAX FROMELECTRICAL METER PAN) TO EACH OUTLET LOCATION WITHIN THE HOME. COAXIAL CABLE SHALLBE RG-6 QUAD SHIELD CABLE.SEE SPECIFICATIONS FOR ADDITIONAL ELECTRICAL REQUIREMENTS.GENERAL LIFE SAFETY NOTESTHIS BUILDING SHALL BE PROVIDED WITH SMOKE AND CARBON MONOXIDE (CO)DETECTORS, INSTALLED IN ACCORDANCE WITH NFPA 72, AND NFPA 720, 2003 EDITION, ATTHE DIRECTION, AND TO THE SATISFACTION OF, THE LOCAL AUTHORITY HAVINGJURISDICTION (AHJ).THE SMOKE AND CARBON MONOXIDE (CO) DETECTOR LOCATIONS SHOWN ON THEDRAWINGS ARE DIAGRAMMATIC ONLY. FINAL LOCATIONS SHALL BE APPROVED BY THELOCAL AUTHORITY HAVING JURISDICTION (AHJ).THE GENERAL CONTRACTOR SHALL FURNISH, LOCATE AND INSTALL APPROVED, CODECOMPLIANT FIRE EXTINGUISHERS. SUCH EXTINGUISHERS SHALL BE FULLY COORDINATEDWITH AND APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.SEE SPECIFICATIONS FOR ADDITIONAL DETECTION AND LIFE SAFETY REQUIREMENTS.ASNEEDEDTOEQUAL5.7SQUAREFEET(5.0 forexceptionabove)20" NET CLEAROPENABLE WIDTHOPENABLEAREA5.7 SQ. FT.MINIMUMAS NEEDED TOEQUAL 5.7 SQUARE FEET(5.0 for exception above)OPENABLEAREA5.7 SQ. FT.MINIMUM24"CLEARMIN.FLOORSILL HEIGHT44" MAXIMUMTO CLEAR OPENINGEXISTING CONCRETE FOUNDATIONNEW 2X4 TYP INTERIOR WALL W/ GYP BD AND PLASTER ON BOTH SIDES2 42 44 1/2''8" to 10"-1/2" GYP BD.-2X WD STUDS @ 16" O.C.-ADD ACOUSTIC BATT INSULATION BTWN BEDROOMS & BATHS/COMMON AREASNEW 2X4 TYP INTERIOR WALL W/ 1-HOUR FRT TYPE X GYP BD ON BOTH SIDES2 42 44 1/2''-5/8" TYPE X GYP BD., IMPACT RESISTANT ON STAIRS AND BETWEEN UNITS-2X WD STUDS @ 16" O.C.-ADD ACOUSTIC BATT INSULATION BTWN BEDROOMS & BATHS/COMMON AREAS-1-HOUR FIRE RATED WALLWALL SECTION LEGENDEXISTING WALLNEW INTERIOR WALLEXISTING CONCRETE FOUNDATIONWALL LEGENDNEW 2x4 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDNEW 2x6 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDScale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONSAs indicatedA001NOTESINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3" = 1'-0"EGRESS WINDOW
WH13ADC452BEXIST.GARAGE BAY 2EXIST.GARAGE BAY 1EXIST.HALF BATHR1Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A100EXISTINGGARAGE FLOORPLANINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1EXISTING GARAGE PLAN
WH13ADC2BEXIST.HALF BATHR1
WHCOSDCOSDCOSDCOSDCOSD13ADC452BSTORAGEEXIST.HALF BATHNEWSPRINKLER ROOMCONCRETE SONOTUBE3' - 3 1/4"EXISTING WATER METER AND WATER HEATEREXISTING HVAC MACHINENEW FIRE RATED WALL BETWEEN UNITS2 LAYERS OF 5/8" TYPE X GYP. BD.R110' - 6"12' - 6 1/4"10' - 6"10' - 0"A=106 SFNEW BEDROOMA=21 SFNEW CLOSETA=140 SFNEW BEDROOM30"ELECTRICRANGEA=53 SFBATH.A=8 SFW/DA=115 SFHALLWAY2' - 0"DN4' - 9"5' - 0"3' - 0"9' - 11 3/4"9' - 0"EGRESS PATH47'-6"EGRESS PATH55'-6"A=377 SFLIVING AND KITCHEN AREA20' - 0 1/4"4' - 6"34' - 5"35' - 9"3' - 0"18' - 6 3/4"12' - 10 1/4"1,012.48 sfA=40 SFW.I.C.A=6 SFCL.13' - 4 1/2"5' - 0"EXISTING WALLNEW INTERIOR WALLEXISTING CONCRETE FOUNDATIONWALL LEGENDNEW 2x4 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDNEW 2x6 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDEGRESS PATHHARD WIRED COMBINATION OF SMOKE DETECTOR AND CARBON MONOXIDE DETECTORLIFE SAFETY FIXTURES LEGENDNOTE: ALL EMERGENCY LIGHT AND EXIT LIGHT ARE ON HARD WIRED, BATTERY BACKUPBATH/LIGHT COMBO EXHAUST FANScale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONSAs indicatedA102PROPOSEDGARAGE FLOORPLANINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1PROPOSED APARTMENT ON GARAGE PLAN
COSDUPDNREFR.REFR.EXISTING WALLNEW INTERIOR WALLEXISTING CONCRETE FOUNDATIONWALL LEGENDNEW 2x4 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDNEW 2x6 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDEGRESS PATHHARD WIRED COMBINATION OF SMOKE DETECTOR AND CARBON MONOXIDE DETECTORLIFE SAFETY FIXTURES LEGENDNOTE: ALL EMERGENCY LIGHT AND EXIT LIGHT ARE ON HARD WIRED, BATTERY BACKUPBATH/LIGHT COMBO EXHAUST FAN13ADC452BNEW BEDROOM #1NEW BEDROOM #2NEWCL.NEWCL.NEWCL.NEW BEDROOM #1LINEN CABINETSTACKW/D42" X 42"SHOWER48" VANITYNEWCL.LINEN CABINETSTACKW/D42" X 42"SHOWER48" VANITYNEWCL.NEW LIVING AREANEW LIVING AREANEW DINING AREANEW DINING AREANEW KITCHENNEW KITCHEN24" RANGENEW KITCHEN24" RANGENEW BATHNEW BATHELECTRICAL&FACP16' - 0"12' - 3 1/2"3' - 1 1/4"16' - 5 1/2"11' - 8 1/4"11' - 8 1/4"22' - 0 3/4"8' - 8 3/4"3' - 11 1/2"6' - 6 1/4"10' - 1 1/4"10' - 3 1/2"2' - 1 3/4"3' - 1 3/4"8' - 0"5' - 10"5' - 5 3/4"6' - 6 1/4"10' - 1 1/4"3' - 1 3/4"2' - 1 3/4"13' - 0 1/2"13' - 0 3/4"EXEXBBEXEXEXEXBBBBEXAAAAEXEX0101010102030303020101010201UPUPDNDNDNDN3' - 6"3' - 6"RAILING 42" HEIGHTRAILING 42" HEIGHT5' - 0"EXREGRESS WINDOWEGRESS WINDOWSDSDSDSDSDSDEXITEGRESS PATH39'-0"EGRESS PATH40'-0"EGRESS PATHBedroom #1 45'-8"Bedroom #2 45'-8"EGRESS PATHBedroom #1 46'-6"Bedroom #2 46'-6"4 INSTANT HOT WATEREX. ALARM PANELMAIN ELEC. PANELFIRE ESCAPE EXIT ONLYR1EGRESS WINDOWScale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONSAs indicatedA103PROPOSED 1STFLOOR PLANINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"11ST FLOOR PLAN
COSDDNEXISTING WALLNEW INTERIOR WALLEXISTING CONCRETE FOUNDATIONWALL LEGENDNEW 2x4 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDNEW 2x6 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDEGRESS PATHHARD WIRED COMBINATION OF SMOKE DETECTOR AND CARBON MONOXIDE DETECTORLIFE SAFETY FIXTURES LEGENDNOTE: ALL EMERGENCY LIGHT AND EXIT LIGHT ARE ON HARD WIRED, BATTERY BACKUPBATH/LIGHT COMBO EXHAUST FAN13ADC2BSTACKW/DNEWCL.NEWCL.NEWKITCHENNEWSTUDIO2' - 5"DNDNDNDNRAILING 42" HEIGHTRAILING 42" HEIGHT3' - 6"5' - 0"3' - 6"5' - 0"EXEXEXEXEXEXEXEXEXEXEX01030404SDSDSDEXITEGRESS PATH33'-4"EGRESS PATH31'-5"EGRESS PATH31'-8"EXTERIOR LIGHTING FIXTUREEXTERIOR LIGHTING FIXTURE34" x 34"SHOWER5' - 9 1/2"4' - 8"015' HEIGHT REFERENCE LINE6' - 0"34" x 34"SHOWER36" x 20"VANITY33" x 20"VANITYNEWSTUDIOSTACKW/DNEWKITCHEN7' - 4 1/4"8' - 3 1/2"E G R E S S P A T H
3 3 '-1 0 "2' - 6"6' - 0"5' - 9 1/2"3' - 9"010505NEWWALK-IN CLOSETNEWBATH.NEWBATH.11"30"ELECTRICRANGE30"ELECTRICRANGE28"TOP FREEZER/REFRIG.28"TOP FREEZER/REFRIG.24"DISHWASHER24"DISHWASHER2' - 0"3' - 3"2' - 4 1/4"03NEWWALK-IN CLOSET017' - 6 3/4"5' HEIGHT REFERENCE LINE8' - 3 1/2"12' - 2 3/4"6' - 11 1/2"16' - 2 1/4"11' - 10 1/4"1' - 6"2' - 6"(2) 2x6 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BD2x6 1-HOUR FRT WALL W/ 5/8" TYPE X GYP BDR1Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONSAs indicatedA104PROPOSED 2NDFLOOR PLANINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"12ND FLOOR PLAN
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTING ATTIC18' -7 1/2"13452Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A200EXISTING FRONTELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1EXISTING FRONT ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTING ATTIC18' -7 1/2"13452Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A201FRONTDEMOLITIONELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1DEMOLITION FRONT ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTING ATTIC18' -7 1/2"13452EXAAAAEXEXEXEXEXEXEXPROPOSED KNOX BOXPROPOSED FIRE BEACONScale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A202PROPOSEDFRONTELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1PROPOSED FRONT ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"ADCBR1Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A203EXISTING LEFTSIDE ELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1EXISTING LEFT SIDE ELEVATION.
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"ADCBR1Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A204DEMOLITIONLEFT SIDEELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1DEMOLITION LEFT SIDE ELEVATION.
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"ADCBEXBBEXR104EXB047"11"Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A205PROPOSED LEFTSIDE ELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1LEFT SIDE ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"13452Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A206EXISTING REARELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1EXISTING REAR ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"13452Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A207DEMOLITIONREAR ELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1DEMOLITION REAR ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"13452EXEXEXEXEXEXBBEXEXBBBBBB0404Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A208PROPOSED REARELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1REAR ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"ADCBR1Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A209EXISTING RIGHTSIDE ELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1EXISTING RIGHT SIDE ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"ADCBR1Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A210DEMOLITIONRIGHT SIDEELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1DEMOLITION RIGHT SIDE ELEVATION
EXISTING 1STFLOOR0' -0"EXISTING 2NDFLOOR10' -1"EXISTINGBASEMENT-11' -3"EXISTING ATTIC18' -7 1/2"ADCBEXBBEXEXR10404Scale:(978) 759-7799contact@soulveplus.comwww.soulveplus.comVERIFY IN FIELD (V.I.F.)ALL DIMENSIONS3/16" = 1'-0"A211PROPOSEDRIGHT SIDEELEVATIONINTERIOR RENOVATION11 POTTER AVE.01/13/2026HYAN-11PAHYANNIS, MA 02601DESIGNDEVELOPMENT3/16" = 1'-0"1PROPOSED RIGHT SIDE ELEVATION