Loading...
HomeMy WebLinkAboutFinal Approved Revised Plan CHADWICKS_15_SZYMANSKI_PROPOSED SITE AND SEPTIC PLAN (stamped) R 2026-2-1116.4 8.5 COVER COVER CBASIN R=15.07CBASIN R=15.28 UP O H W O H W O H W 10 10 12 12 14 16 18 14 16 18 18 18 18 18 1816 S 88° 06' 07" W 90.00'S 1° 53' 53" E125.00'N 1° 53' 53" W125.00'N 88° 06' 07" E 90.00' GRAVEL DRIVEWAY NATURALLY VEGETATED EDGE O F B. V. W. DECKRAMPGAS METER #15 DWELLIN G PLANTS PLANTS 7.0' 23.0' CHADWICK AVENUE (40' WIDE - PUBLIC) EDGE OF PAVEMENTPATRICIA STREET(40' WIDE - PUBLIC)OH W OH W EDGE OF PAVEMENT PARCEL 246-071 PARCEL 246-070 (ON SEWER) (ON TOWN WATER) PARCEL 246-068 (ON TOWN WATER) LOT 2 11,250 S.F. HEDGE HEDGE FZ FZ FZ FZ FZ FEMA ZONE AE(EL.10') FEMA ZONE X SEWER LINE EXISTS ON 100' B U F F E R F R O M EDG E O F B. V. W.50' BUFFER FROMEDGE OF B.V.W.WWWELEV=15.55 CB BENCHMARK BVW-1 BVW-2 BVW-3 BVW-4 BVW-550' BUFFER50' BUFFER50' B U F F E R 50' BUFFER 50' BU F F E R100' BUFFER100' B U F F E R 100' B U F F E R 100' BUFF E R 100' BUFFER 8 8 853.4'59'±SS LOCATION OF EXISTING SEPTIC SYSTEM TO BE CONFIRMED PRIOR TO CONSTRUCTION. NOTHING ON FILE WITH BARNSTABLE B.O.H. EXISTING LEACH PIT TO BE REMOVED OR ABANDONED PER 310 CMR 15 30.6'PROPOSED H-20 SAS 2-500 GALLON CHAMBERS IN 10' X 29' LEACH FIELD10.0'29.0'2.6'4.0' 4.0' PROPOSED H-20 1,500 GALLON SEPTIC TANK 10.0'EXISTINGWWWEEEEEGGGGG 10.1'10.0' CRAWL SPACE FDN. FULL FOUNDATION EXISTING DWELLING TO BE RAZED20.0'10.8'12.2'30.3' PROPOSED SILT FENCE WORK LIMIT TO BE INSTALLED PRIOR TO CONSTRUCTION 13.4' 14.6'30.0'TH-1&2 TH-3&4 100'D D D D DRYWELL (TYP) PROPOSED PAVED DRIVEWAY S VENT BENCHMARK MAG NAIL ELEV. 15.89 SLAB FDN PROPOSED DWELLING FFE 21.2 NAVD PROPOSED ACCESS STAIRS 50'68.6'62.4'MITIGATION DEMARCATION 24" TALL 4"X4" GRANITE POSTS WITH 12" EXPOSED TO BE INSTALLED AT LEAST EVERY 15' OR APPROVED ALTERNATIVE28.3'BVW FLAGGED BY K. KOS ON 7/18/2025 NOT TO SCALELOCUS MAP N N NAD 83SEPTIC SYSTEM NOTES 1.ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.00), AND THE LOCAL BOARD OF HEALTH. 2.THERE SHALL BE NO CHANGES MADE IN THIS PLAN WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER AND LOCAL BOARD OF HEALTH. 3.ALL ERRORS, OMISSIONS, AND CHANGE OF CONDITIONS AT THE SITE SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PERFORMING THE RELATED WORK. 4.ALL DISTURBED AREAS ARE TO BE LOAMED, SEEDED AND MAINTAINED TO PREVENT EROSION. 5.FOR PROPER PERFORMANCE, SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND WHEN THE TOTAL DEPTH OF SCUM AND SOLIDS EXCEEDS 1/3 THE LIQUID DEPTH OF THE TANK, THE TANK SHOULD BE PUMPED. 6.THIS SYSTEM HAS BEEN DESIGNED FROM DATA REVIEWED AND ACKNOWLEDGED BY THE MASS. D.E.P. AND THE LOCAL BOARD OF HEALTH; AND CONFORMS WITH THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE 5. NO GUARANTEE OF PERFORMANCE IS EXPRESSED OR IMPLIED. 7.TEST HOLE INFORMATION SHOWN HEREON IS LIMITED TO SOIL CONDITIONS FOUND AT THAT PARTICULAR TEST HOLE LOCATIONS AND IS NOT CONSIDERED AN IMPLIED OR EXPRESSED WARRANTY OF SOIL CONDITIONS BEYOND LIMITS OF SUCH TEST HOLES. 8.ALL ORGANIC AND UNSUITABLE MATERIAL MUST BE REMOVED FROM THE AREA DIRECTLY UNDER AND 5 FEET BEYOND THE PROPOSED LEACHING FACILITY. THIS AREA MUST BE BACKFILLED TO THE ELEVATIONS INDICATED ON THESE PLANS WITH SELECT ON-SITE OR IMPORTED SOIL MATERIAL, CONSISTING OF CLEAN GRANULAR SAND OR OTHER GRANULAR MATERIAL, FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS SHALL NOT BE USED. THE FILL MATERIAL SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 - 310 CMR SECTION 15.255 (3) AND SHALL HAVE PERCOLATION RATE OF BETWEEN TWO AND FIVE MINUTES PER INCH, BEFORE AND AFTER PLACEMENT. 9.ALL STONE MUST BE DOUBLE WASHED AND FREE FROM FINES AND ANY ORGANIC MATERIAL AND MUST HAVE LESS THAN 0.2 PERCENT MATERIAL FINER THAN A NUMBER 200 SIEVE. 10.THE DESIGNER HAS NOT BEEN RETAINED BY THE CLIENT TO CONSTRUCT OR SUPERVISE THE CONSTRUCTION OF THE SYSTEM. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ARRANGEMENTS FOR INSPECTION OF INSTALLATION OF THE SYSTEM WITH THE LOCAL BOARD OF HEALTH. 11.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL OF ALL SYSTEM COMPONENTS. 12.TIGHT JOINT PIPING MATERIAL TO CONSIST OF POLYVINYL CHLORIDE (P.V.C.) SCHEDULE 40, UNLESS OTHERWISE NOTED. 13.THE CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER FOR CONSTRUCTION INSPECTION AFTER EXCAVATION FOR THE LEACHING BED (PRIOR TO THE PLACEMENT OF STONE) AND ALSO AFTER PLACEMENT OF PIPE & STONE PRIOR TO BACKFILLING. 14.DESIGN ENGINEER SHALL CERTIFY CONSTRUCTION OF SYSTEM AND MATERIALS INSTALLED. THE CONTRACTOR SHALL PROVIDE A SIEVE ANALYSIS OF THE FILL MATERIAL REQUIRED. AN AS-BUILT PLAN SHALL BE SUBMITTED TO THE LOCAL BOARD OF HEALTH UPON COMPLETION. 15.NO RUBBER TIRE CONSTRUCTION MACHINERY SHALL DRIVE OVER THE PROPOSED SEPTIC BED EXCAVATION DURING CONSTRUCTION. 16.DIG-SAFE AND ALL OTHER NECESSARY AUTHORITIES SHALL BE NOTIFIED FOR THE PROPER LOCATION OF EXISTING UTILITIES PRIOR TO ANY EXCAVATION. 17.WATER SERVICE LINE SHALL BE LOCATED AND MARKED PRIOR TO ANY EXCAVATING AND 10' MIN. SETBACK DISTANCE FROM SAID SERVICE TO THE SEPTIC SYSTEM SHALL BE MAINTAINED. 18.ALL WATER LINES WITHIN 10' OF SEPTIC SYSTEM COMPONENTS SHALL BE SLEEVED WITHIN 4" PVC SCHEDULE 40 PIPE. SOIL EVALUATOR'S LOG PERCOLATION RATE = < 2 MINUTES / INCH IN C1 AND C2 LAYERS DEPTH TO GROUNDWATER = NONE ENCOUNTERED, ADJUSTED HIGH GROUNDWATER = ESTIMATED AT ELEVATION 7 (NAVD88) PER WETLAND FLAGS NO GROUNDWATER OBSERVED IN TEST HOLE ELEV. 7.3 OBSERVATIONS BY: C. ROWLAND, P.E. WITNESSED BY: DAVID STANTON, R.S. DATE TESTED: SEPTEMBER 3, 2025 Depth from surface in inches Soil Horizon Soil Texture (USDA) Soil Color (Munsell) Soil Mottles and Depth Other Relative Factors DEEP OBSERVATION HOLE TH#1&2, ELEVATION 18.3 0 - 6"A SANDY LOAM 10 YR 3/2 6" - 24"B LOAMY SAND 10 YR 5/8 W/ GRAVEL 24" - 48"C1 COARSE SAND 10 YR 6/4 NO W/ GRAVEL 48" - 132"C2 MEDIUM SAND 10 YR 7/4 NO STRIATED DEEP OBSERVATION HOLE TH#3&4, ELEVATION 18.5 0 - 6"A SANDY LOAM 10 YR 3/2 6" - 23"B SANDY LOAM 10 YR 5/8 W/ GRAVEL 23" - 52"C1 COARSE SAND 10 YR 6/4 NO W/ GRAVEL 52" - 132"C2 MEDIUM SAND 10 YR 7/4 NO STRIATED DESIGN DATA 1.TYPE OF ESTABLISHMENT: 3-BEDROOM SINGLE FAMILY RESIDENCE 2.SEWAGE SYSTEM DESIGN FLOW: 110 GALLONS PER BEDROOM = 110 x 3 = 330 GPD 3.NOTE: THIS SEPTIC SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER 4.SEPTIC TANK CAPACITY REQUIRED, MINIMUM OF 200% OF DESIGN FLOW OR 1,500 GAL. = 200% x 330 GALLON = 660 GALLON (USE 1,500 GALLON TANK) 5.DESIGN PERCOLATION RATE: ASSIGNED LESS THAN 5 MINUTES PER INCH 6.SOIL ABSORPTION SYSTEM TYPE: 2-500 GALLON CHAMBERS IN STONE FIELD SYSTEM 7.LEACHING AREA REQUIRED: MINIMUM 330 GPD / (0.74 GPD/S.F., CLASS I SOIL) = 445.9 S.F. 8.LEACHING SYSTEM PROPOSED: 29.0' LONG x 10.0' WIDE x 2' HIGH SYSTEM BOTTOM AREA PROPOSED = 29' x 10' = 290.0 S.F. SIDE AREA PROPOSED = 2 x (29' + 10') x 2' = 156.0 S.F. TOTAL AREA PROPOSED = 290.0 + 156.0 = 446.0 S.F. 9.LEACHING SYSTEM CAPACITY PROPOSED = 446.0 S.F. x 0.74 GPD/S.F. = 330.0 GPD PREPARED FOR: PREPARED BY: DRAWING TITLE: PROJECT: ASSESSORS INFORMATION: SUMMERFIELD PARK 800 FALMOUTH ROAD SUITE 301C MASHPEE, MA 02649 508.477.7272 PHONE 508.477.9072 FAX www.CapeEng.com SHEET NO.: OF DATE: DRAWN BY:CHECKED BY: 1 1 CENTERVILLE (BARNSTABLE), MASSACHUSETTS HYANNIS, MA 02601 137 BUCKWOOD DRIVE LISA SZYMANSKI JGP/CTR CTR/JJF SEPTEMBER 16, 2025 MAP 246-069 DESCRIPTIONDATE CHKBY 2/11/26 ADD INFORMATION ON WHEN WETLAND WAS FLAGGED CTR CTR NOTICE THIS PLAN MAY NOT BE ADDED TO, DELETED FROM, OR ALTERED IN ANY WAY BY ANYONE OTHER THAN CAPE & ISLANDS ENGINEERING, INC. UNLESS AND UNTIL SUCH TIME AS AN ORIGINAL (RED) STAMP APPEARS ON THIS PLAN NO PERSON OR PERSONS, MUNICIPAL OR PUBLIC OFFICIAL MAY RELY UPON THE INFORMATION CONTAINED HEREIN; AND THIS PLAN REMAINS THE PROPERTY OF CAPE AND ISLANDS ENGINEERING, INC. COPYRIGHT (C) BY CAPE & ISLANDS ENGINEERING, INC. ALL RIGHTS RESERVED 15 CHADWICK AVENUE CHADWICKS_15_SZYMANSKI_SS PROPOSED SITE AND SEPTIC PLAN N LOCUS GENERAL NOTES LOCATIONS ARE BASED ON AN "ON THE GROUND" INSTRUMENT SURVEY AND ELEVATIONS BASED ON THE NAVD 1988 DATUM. COORDINATE SYSTEM USED IS THE MA-MAINLAND COORDINATE SYSTEM, DATUM: NAD 83, UNITS: U.S. SURVEY FEET. DIMENSIONS OF EXISTING BUILDINGS AND BUILDING OFFSETS SHOWN HEREON ARE TO CORNER BOARDS OR SIDING EXTENTS AND ARE DISPLAYED IN ENGINEERING UNITS WITH A PRECISION OF ONE TENTH (0.1') OF A FOOT. LOT COVERAGE IS CALCULATED TO CORNER BOARDS. THE FINISHED FLOOR ELEVATION (FIN. FL. EL.) SHOWN HEREON IS BASED ON AN ASSUMED 1" LOWER THAN THE SURVEYED THRESHOLD ELEVATION. AN INTERIOR INSPECTION OF BUILDINGS WAS NOT PERFORMED. ZONING DISTRICT: RB PROPERTY IS LOCATED WITHIN AN AREA HAVING A ZONE DESIGNATION OF AE (ELEV. 10) & MINIMAL FLOOD HAZARD ZONE X BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), ON FLOOD INSURANCE RATE MAP NO. 25001C0564J, WITH A MAP EFFECTIVE DATE OF JULY 16, 2014. THIS LOT IS NOT LOCATED WITHIN A DEP APPROVED ZONE II WELLHEAD PROTECTION AREA. THIS LOT IS NOT MAPPED WITHIN A MESA NATURAL HERITAGE AND ENDANGERED SPECIES AREA. THIS LOT FALLS WITHIN THE SALTWATER ESTUARY PROTECTION OVERLAY DISTRICT. WIND EXPOSURE CATEGORY: ZONE B LOT COVERAGE: LOT AREA = 11,250 S.F. EXISTING LOT COVERAGE BY STRUCTURES: HOUSE = 1,158 S.F. (10.3%) PROPOSED LOT COVERAGE BY STRUCTURES: HOUSE & GARAGE = 1,885 S.F. (16.8%) A COMPREHENSIVE ZONING ANALYSIS HAS NOT BEEN PERFORMED BEYOND THE ITEMS LISTED ABOVE. DEED REFERENCE: BOOK 23294 PAGE 130 PLAN REFERENCE:BOOK 116 PAGE 73 OWNER: RICHARD C. JR. & LISA SZYMANSKI 15 CHADWICK AVENUE CENTERVILLE (BARNSTABLE), MA 02601 0 SCALE: 10 20 40 1"=20' S=0.02 L=15' S=0.01 L=20'S=0.01 L=27' MAX PRECAST H-20 500-GALLON CHAMBERS USE (2) 500-GALLON CHAMBERS WITH DOUBLE WASHED CRUSHED STONE 28" AT ENDS AND BETWEEN CHAMBERS, 31" ON THE SIDES EFFECTIVE DIMENSIONS: LENGTH =29.0', WIDTH = 10.0', HEIGHT = 2.0'4.33'4.58'36"OVERALLHEIGHTH-20 D-BOX WITH SPEED LEVELERS 24"EFFECTIVESIDEWALL15' MIN. BREAKOUT GRADEBACK FILL WITH 9" MIN. 36" MAX. CLEAN MATERIAL CONTRACTOR SHALL CONTACT ENGINEER TO ASSESS EXISTING SOIL MATERIAL PRIOR TO INSTALLATION OF LEACHING SYSTEM. UNSUITABLE MATERIAL ENCOUNTERED DURING INSTALLATION SHALL BE REMOVED - REFER TO SEPTIC SYSTEM NOTE 8 PROPOSED SEPTIC TANK 1,500 GALLON, H-20 LOADING 6" MIN. COMPACTED & STABLE CRUSHED STONE BASE FILTER FABRICS=2% MINIMUM GAS BAFFLE SCH. 40 PVC TEES10"14"RISER AND COVER TO BE SET TO WITHIN 6" OF FINISHED GRADE & SERVE AS INSPECTION PORT SEWAGE SYSTEM PROFILE & DETAILS NOT TO SCALE NOTES: 1.FURNISH RISERS TO SET COVERS WITHIN 6 INCHES OF FINISH GRADE. 2.H-20 SEPTIC TANK AND CHAMBERS AND H-20 DISTRIBUTION BOX (D-BOX), AND SCHEDULE 40 PVC PIPE THROUGHOUT. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A TRENCH PERMIT FROM THE LOCAL MUNICIPALITY IN WHICH THE WORK IS BEING PERFORMED. 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL FIRST 2' SHALL BE SET LEVEL 6"16.704 19.52 DWELLING 17.003 16.455 19.013 18.512 15.466 15.307 15.008 13.009 16.0010 18.511 FIRST FLOOR ELEV. CRAWL SPACE 6" ADDITIONAL DROP FOR FUTURE I.A. SYSTEM NO GROUNDWATER ENCOUNTERED EL. 7.3 (NAVD88)5.7'*ELEVATIONS TO BE CONFIRMED 21.2*1 12.1214 16.0014 SCHEDULE OF ELEVATIONS 1 FIRST FLOOR = 2 ADJACENT ELEVATION = 3 PIPE INV. AT FOUNDATION = 4 INV. OF PIPE AT SEPTIC TANK INLET = 5 INV. OF PIPE AT SEPTIC TANK OUTLET = 6 INV. OF PIPE AT D-BOX INLET = 7 INV. OF PIPE AT D-BOX OUTLET = 8 INV. OF PIPE AT LEACHING FIELD INLET = 9 BOTTOM OF LEACHING FIELD = 10 TOP OF STONE 11 FINISHED GRADE OVER LEACHING FACILITY = 12 FINISHED GRADE OVER D-BOX = 13 FINISHED GRADE OVER SEPTIC TANK = 14 BOTTOM OF SEPTIC TANK = 15 CRAWL SPACE ELEVATION = CONSERVATION NOTES PRIOR TO ANY WORK COMMENCING, THE DEP FILE NUMBER SHALL BE POSTED ON A SIGN ON THE STREET SIDE OF THE LOT AND MAINTAINED IN A VISIBLE CONDITION THROUGHOUT THE PROJECT. THE LIMIT OF WORK WILL BE INSTALLED PRIOR TO ANY WORK, EXCAVATION, CONSTRUCTION OR CLEARING OF VEGETATION, IN ORDER TO PREVENT DAMAGE TO THE INTERESTS OF THE ACT AND BYLAW. THE LIMIT OF WORK WILL CONSIST OF A ROW OF STAKED SEDIMENT STOP OR COMPOST ROLL WITH SILT FENCE BACKING. THE SEDIMENT STOP ROLL WILL BE REPLACED AS NECESSARY TO BE MAINTAINED IN GOOD CONDITION THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. NO FILL WILL BE ALLOWED TO BE PLACED AGAINST THE LIMIT OF WORK AT ANY TIME. UPON COMPLETION OF ALL CONSTRUCTION AND STABILIZATION OF THE SITE, SEDIMENT STOP ROLL WILL BE REMOVED AND PROPERLY DISPOSED OF. PRIOR TO ANY WORK COMMENCING, ADVANCE WRITTEN NOTIFICATION WILL BE PROVIDED TO THE LOCAL CONSERVATION COMMISSION. NO DEBRIS, EQUIPMENT OR MATERIALS WILL BE STORED, EVEN TEMPORARILY, OUTSIDE THE DESIGNATED LIMIT OF WORK AREA WITH THE EXCEPTION OF EQUIPMENT AND MATERIALS RELATED TO THE PLANTINGS FOR THE REQUIRED MITIGATION. THE CONSTRUCTION SITE WILL BE CLEANED DAILY TO REMOVE ANY LOOSE DEBRIS. ALL DISTURBED AREAS WITHIN THE LIMIT OF WORK REQUIRING RESTORATION WILL BE STABILIZED TO PREVENT EROSION. STABILIZATION WILL BE DONE IMMEDIATELY FOLLOWING COMPLETION OF CONSTRUCTION. RNDS PRO FLOW-WELL PLAN VIEW 2'6'2'4" PVC INLET 3/4"-1-1/2" DOUBLE WASHED STONE ROOF LEADER OVERFLOW PIPE FINISH GRADE, VARIES SPLASH PLATE 8" MIN. LOAM COVER PIPE, S= 1.0% 4" HDPE DRAIN 2'2' INLET SECTION VIEW DRY WELL DETAIL -NOT TO SCALE- DRY WELL NOTES A SYSTEM OF GUTTERS, DOWNSPOUTS AND DRY WELLS SHALL BE USED TO RECHARGE STORMWATER RUNOFF. PICTURES OF DRY WELL SHOULD BE TAKEN DURING INSTALLATION AND SUPPLIED TO CONSERVATION COMMISSION AS PART OF THE CERTIFICATE OF COMPLIANCE REQUEST. 6" MINIMUM BEDDING STONE PROJECT STATISTICS 1.PROPOSED DISTURBANCE 0-50' BUFFER:0 S.F. 2.PROPOSED DISTURBANCE 50-100' BUFFER (WITHIN WORK LIMIT):4,425 S.F. 3.PROPOSED UNDISTURBED BUFFER WIDTH:50 FEET 4.EXISTING DISTANCE FROM STRUCTURE TO B.V.W.:59 FEET 5.PROPOSED DISTANCE FROM STRUCTURE TO B.V.W.: 68.6 FEET 6.PROPOSED DISTANCE FROM HARDSCAPE TO B.V.W.:62.4 FEET 7.PROPOSED DISTANCE FROM SEPTIC S.A.S. TO B.V.W.: 112 FEET 5.PROPOSED DISTANCE FROM SEPTIC TANK TO B.V.W.: 110 FEET MITIGATION PLANTINGS CALCULATION 0 - 50' BUFFER EXISTING PROPOSED NET CHANGE DEVELOPMENT (STRUCTURES)0 S.F.±0 S.F.±0 S.F.± TOTAL DEVELOPMENT AREAS 0 S.F.±0 S.F.±0 S.F.± 50 - 100' BUFFER EXISTING PROPOSED NET CHANGE STRUCTURES 923 S.F.±1,811 S.F.±888 S.F.± DECKS, DRIVEWAY, HARDSCAPE, ETC.234 S.F.±91 S.F.±-143 S.F.± TOTAL DEVELOPMENT AREAS 1,157 S.F.±1,902 S.F.±745 S.F.± MITIGATION @ 4:1 RATIO (0-50') & @ 3:1 RATIO (50-100' BUFFER):1,490 S.F.± UNDISTURBED 50' BUFFER TO REMAIN (NO MITIGATION REQUIRED)N/A S.F.± PROPOSED VENT, FINAL LOCATION TO BE DETERMINED IN THE FIELD 3' MIN.DIRECTIONS: FROM MAIN STREET HYANNIS: TAKE MAIN STREET WEST TOWARDS THE WEST END ROTTARY. TAKE THE THIRD EXIT ONTO SCUDDER AVENUE. AT THE STOP SIGN, TURN RIGHT ONTO SMITH STREET AND CONTINUE RIGHT ONTO CRAIGVILLE BEACH ROAD. TURN RIGHT ONTO STRAWBERRY HILL ROAD AND RIGHT ONTO CHADWICH AVENUE. #15 IS ON THE RIGHT. OHW HYDRANT WATER SHUTOFF CATCH BASIN SQUARE UTILITY POLE GUY POLE GUY WIRE LIGHT POLE SIGN CONIFEROUS TREE DECIDUOUS TREE TREE LINE OVERHEAD WIRES STONE WALL POST & RAIL FENCE STOCKADE FENCE x x x PICKET ROW xx xx CHAIN LINK FENCE LEGEND IRON PIPE FOUND CONCRETE BOUND IP CB TREE STUMP STONE BOUNDSB RC ROD CAP SHRUB CONIFEROUS SHRUB AREA OF STRUCTURE INCLUDED IN EXISTING LOT COVERAGE