HomeMy WebLinkAbout20260318 - HANOVER HYANNIS SP CLUBHOUSE IFC4X 212 X 212 ROUGH BRASS F.D.CWALL MOUNTEDLOCATED 18" TO 4-0 ABOVEOUTSIDE GRADESPRINKLER HEAD LEGEND4" DRY VALVE w/ QUICK OPENING DEVICE4" TO FDC6"397 GALLONS TOTAL VOLUMEBUILDING 1BUILDING 3BUILDING 2
BUI
LDI
NG 4BUILDING 5CLUBHOUSEWI
L
KENS
L
ANEKID
D'S HILL R
O
AD HYD.HYD.HYD.HYD.HYD.HYD.HYD.HYD.68.00 0.0064.00 1704.0012" D.I.12" D.I.12" D.I.8" D.I.8" D.I.8" D.I.8" D.I.8" D.
I
.8" D.I.8" D.I.8" D.I.8" D.I.8" D.
I
.
8" D.I.(IN FEET)0SCALE:1/64" = 1'-0"
VESTIBULEJANITORWOMENPHONE ROOMPHONE ROOMMENPACKAGEWORKROOMASST. MGR.MGR.FITNESSMAILSCREENINGHALLLEASINGCO WORKINGLOBBYRISER ROOMIT/AVF.D.+10'-6"AFF+10'-0"AFF+10'-0"AFF+8'-6"AFFSCREENING111+9'-6"AFFCOURTYARD113+9'-6"AFFLOBBY102CO WORKING110+10'-0"AFF+10'-0"AFFASST MGR106MGR105+10'-0"AFF+10'-6"AFFLEASING103CLOSING104CLOSING107+9'-0"AFFWORKROOM108IT/AV109PACKAGE114+9'-0" AFF+10'-6"AFFCATHEDRALCEILING4:12 FROM:+10'-6"AFFto~14'-0"AFFFITNESS115+10'-6"AFFMAIL122+10'-0"AFFWOMEN117MEN118+10'-6"AFF+9'-0"AFF+9'-0"AFFFRONT PORCH101+10'-6"AFF+9'-0"AFFPHONE ROOM120+10'-0"AFF+10'-0"AFF+9'-0"AFF+10'-6"AFF+10'-6"AFF+10'-6"AFF+9'-0"AFF+10'-6"AFFCATHEDRALCEILING4:12 FROM:to~16'-6"AFFFFFFFFFFOSOSOSOSATTIC ACCESS PANELWITH LADDERATTIC ACCESS PANEL WITH LADDERFOSOSOSOSOSOSOSF+10'-0"AFF+10'-6"AFF+10'-6"AFF+8'-6"AFF+8'-6"AFF+8'-6"AFF+9'-0" AFFCL+9'-0"AFF+10'-0"AFFREFER LANDSCAPEDRAWINGS FORLIGHTING OF THISAREA"OSSZ1SZ1SZ1SZ3SZ3SZ3SZ3SSSSSSZ1leftZ2Z2Z2Z2Z2LLCOSF+9'-0"AFFPHONE ROOM120CLSZ1SZ1SZ1OSOSOSOSOSOSOS+9'-6"AFFOSThis system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat the base of the riser.Hose stream allowance ofis included in the above.3FIRST FLOORPLATINUM FIRE10/24/25HANOVER HYANNIS PH II55 WILKENS LANE0.12535 ft²695.2 gpm41.5 psiLIGHT HAZARD31Dry13.4 ft/s0 gpm595.2 gpm0 gpm100 gpm0 gpm695.2 gpm0 gpm695.2 gpm41.5 psi67.2 psi25.8 psiThis system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat the base of the riser.Hose stream allowance ofis included in the above.4FIRST FLOORPLATINUM FIRE10/24/25HANOVER HYANNIS PH II55 WILKENS LANE0.12535 ft²746.9 gpm42.6 psiLIGHT HAZARD34Dry14.56 ft/s0 gpm646.9 gpm0 gpm100 gpm0 gpm746.9 gpm0 gpm746.9 gpm42.6 psi67.1 psi24.5 psi(IN FEET)0SCALE:1/8" = 1'-0"4816
12:1212:124:12 4:12
12:1212:12
12:1212:1212:12 12:12
12:1212:121 HR RATEDATTIC ACCESS(LOCKED)1 HR RATEDATTIC ACCESS(LOCKED)12" / 12"12" / 12"4:124:12D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.4:12
This system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat the base of the riser.Hose stream allowance ofis included in the above.1ATTICPLATINUM FIRE10/24/25HANOVER HYANNIS PH II55 WILKENS LANE0.12250 ft²335.6 gpm44.9 psiLIGHT HAZARD9Dry10.87 ft/s0 gpm235.6 gpm0 gpm100 gpm0 gpm335.6 gpm0 gpm335.6 gpm44.9 psi67.8 psi22.9 psiThis system as shown oncompany print nodatedforatcontract nois designed to discharge at a rate ofa maximum area ofwhen supplied with water at a rate ofOccupancy classification:Commodity classification:Maximum storage height:Storage arrangement:Number of heads flowing:System Type:Maximum velocity:Flow from In-Rack sprinklers:Flow from Overhead sprinklers:Flow from Inside Hoses:Flow from Outside Hoses:Other fixed flows:Total flow in system piping:Additional flow at/beyond source:Total of all flows:Calculation results for Design Areagpm/ft² (L/min/m²) of floor area over-Surplus Pressure at Source:Pressure Required at Source:Pressure Available at Source:atat the base of the riser.Hose stream allowance ofis included in the above.2ATTICPLATINUM FIRE10/24/25HANOVER HYANNIS PH II55 WILKENS LANE0.13040 ft²464.4 gpm55.2 psiLIGHT HAZARD9Dry15.4 ft/s0 gpm364.4 gpm0 gpm100 gpm0 gpm464.4 gpm0 gpm464.4 gpm55.2 psi67.6 psi12.5 psiCOVEREDFROMBELOW(IN FEET)0SCALE:1/8" = 1'-0"4816