Loading...
HomeMy WebLinkAboutHanover Hyannis II - 100% IFC Electrical - 3.18.26··EXITGENERAL NOTESMOUNTING HEIGHTSABBREVIATIONSLIGHTING FIXTURESWIRING DEVICES - RECEPTACLESBRANCH CIRCUITRYFIRE ALARM SYSTEMGENERAL CIRCUITRYDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:24 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE0.00Electrical Legendand GeneralNotes 1AAK3CCBBCCK2K2K2K2A2A2C1C1A1A1A1JJBAAK3K3Electrical Site PlanScale:1"=30'-0"CDUEUExxxxxxxxxxxx xxxx UEUEUE UEWWWWWWWWWWWWSD SD SD SD52607080 90LANE70706060505060 8050 50 5050 44 42 4244 EXISTING GARAGEDRAIN A G E E A S E M E N TDRAINAGE EASEMENT DRAINAGE EASEMENT VARIABLE WIDTH SLOPE EASEMENTVARIABLE WIDTH SLOPE EASEMENT 50' WI D E F R O N T Y A R D S E T B A C K30' WIDE SIDE YARD SETBACK30' WIDE SIDE YARD SETBACK30' WIDE SIDE YARD SETBACK30' WIDE SIDE YARD SETBACK30' WIDE SIDE YARD SETBACK30' WIDE SIDE YARD SETBACK30' WIDE SIDE YARD SETBACKRESIDENTIAL BUILDING 1 4 STORIES FFE=51.50 RESIDENTIAL BUILDING 2 4 STORIES FFE=51.50 RESIDENTIAL BUILDING 3 4 STORIES FFE=51.50 LEASING /CLUB BUILDING 6 FFE=52.50 RESIDENTIALBUILDING 44 STORIESFFE=53.00 RESIDENTIALBUILDING 54 STORIESFFE=53.00 POOL GARAGE B FFE=50.20 GARAGE EFFE=50.20 GARAGE FFFE=50.50GARAGE GFFE=52.40 GARAGE HFFE=52.60GARAGE DFFE=50.90MAINTENANCEBIKE STORAGE BIKE STORAGE FFE=50.20 10 710107 6 2 6566397616610108981101055999 8 7 6 7 5 5 6 5 10 1010 101086 4 8 10 5 7 6 4 7 10 LOT 2A 652,497 S.F. 14.98 ACRES GEN LOT 2B 90,016 S.F. 2.07 ACRES LOT 2C8,546 S.F.0.20 ACRES87773 7EV-FEV-FEVEVEV EV EV-F EV EV EVEV-FEVEV-FEVEVEV-F EVEV EV EV EV-FEVEV EV EV EV-F EVEV EVEVEVEVEV PROPOSED LOT LINE PROPOSED LOT LINEPROPOSED LOT LINEPROPOSED ACCESS EASEMENT50.0' PROPO S E D 1 5' W I D E S E W E R E A S E M E N T GARAGE A FFE=50.90 6GARAGE CFFE=51.1010 6 6EV-FEVEVEVEV 6EVEV5 EMBAYMENT LINE (TYP.) EMBAYMENT LINE (TYP.) EMBAYMENT LINE (TYP.) T Tr TTrTTr T Tr TT Tr 2 6FFE = 50.90EV EV EV-F EV-FEV-F EV-FEVEVEV-FEV-FEV-FEVEVEV-F EV-F EV-F EV-F EV-F EV-F EV-FEV-F EV-F EV-F EV-F EV-FEVEVEV-F EV-F POOL EQUIP. ENC. CONNECT GAS PER NATIONAL GRID WWWWWWWWWW W W W W WSSSSSSSSSS SS FM FM FMFMFMFMFMSSSSSSSSWWSSSSWSS SS W WWW W W WW W W W W W W W 1-1/2" DOM. SERVICE FIRE SERVICE 4" DOMESTIC SERVICE FIRE SERVICE 4" DOMESTIC SERVICE FIRE SERVICE DOMESTIC SERVICE FIRE SERVICE FIRE SERVICE4" DOMESTIC SERVICE 4" DOMESTICSERVICEFIRE SERVICE 12" CLDI 12" CLDI12" CLDI8" CLDI8" CLDI8" CLDI8" CLDI8" CLDI8" CLDI8" CLDI8" CLDI 8" CLDI 8" CLDI 8" CLDI8" CLDI6" CLDIGATE VALVE (TYP.) GATE VALVE (TYP.) FIRE HYDRANT (TYP.) GATE VALVE (TYP.) FIRE HYDRANT (TYP.) GATE VALVE (TYP.) 8" CLDI SSWE/T/D E/T/D E/T/D E/T/D NOTE:FIRE HYDRANT TO BE LOCATED WITHIN 100 FEET OF THE BUILDING'S FDC. NOTE:FIRE HYDRANT TO BE LOCATED WITHIN 100 FEET OF THE BUILDING'S FDC. NOTE:FIRE HYDRANT TO BE LOCATED WITHIN 100 FEET OF THE BUILDING'S FDC. NOTE:FIRE HYDRANT TO BE LOCATEDWITHIN 100 FEET OF THE BUILDING'S FDC.NOTE:FIREHYDRANT TO BE LOCATEDWITHIN 100 FEET OF THEBUILDING'S FDC. NOTE:FIRE HYDRANT TO BE LOCATED WITHIN 100 FEET OF THE BUILDING'S FDC.E/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/DE/T/D E/T/D E/T/DE/T/DE/T/DSS8" CLDIINSTALL 12"X8" REDUCERSSSSE/T/DW W 1-1/2" TYPE K COPPER CLDI SSW SS1" TYPE K COPPER 1" TYPE K COPPER GGGG G G G GG G GGGGGGAS SERVICE W/ METER GAS SERVICE W/ METER GAS SERVICE W/ METERGGGGGGGGGGAS SERVICE W/ METER GAS SERVICEW/ METER WW W12"X12X12" TEE W/3 GATE VALVES 8"X8X8" TEE W/3 GATE VALVES 12" CLDI 12"X8" REDUCER K3EBBBBBBWWHHWKKWWVV~CCBUILDING 2TYPE 02AFHGCCA1A1BBKK2K2WWCCWBBWWBUILDING 5TYPE 02A1A1C1C1C1C1BUILDING 4TYPE 02C1C1C2C2C1C1A1A1DDC1A1BUILDING 6CLUBJJJJBK1K1WWWWC1C1JJJJBUILDING 1TYPE 01BUILDING 3TYPE 01KKKUU~KKA3A3KKBBBC1C1A1A1C1C1Typical Ductbank Section Legend, Details & DimensionsScale:NoneSECTION "A-A"SECTION "B-B"SECTION "H-H"2SECTION "A1-A1"SECTION "A2-A2"SECTION "A3-A3"SECTION "C-C"SECTION "C1-C1"SECTION "K-K"SECTION "K2-K2"SECTION "K3-K3"SECTION "W-W"SECTION "U-U"SECTION "C2-C2"SECTION V-V"SECTION "D-D"SECTION "J-J"Lift Pump Station Part PlanScale:None3Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:30 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE0.01Electrical SitePlanAS NOTED Electrical Site Lighting and Power Plan1Scale:1"=30'-0"PROPOSED ACCESS EASEMENTPROPO S E D 1 5 ' W I D E S E W E R E A S E M E N T 600.0'GGGGGGGGGGGGGG G G G G G 60 65 70 50 55606570 50 45 45 50 50 RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE +1+2+3+4+1'+2'Crown Lawnfor DrainageBermPoolEquipment+3+2+1+0'+0'GENERATORPUMPSTATIONLFPARC CENTRECHAIRNO ARMSLF PARC CENTRE CHAIR NO ARMS LF PA R C C E N TR E CH A I R NO A R M S LFPARC CENTRETABLE24 ROUNDRH PROVENCECLASSIC SOFA 98RH PROVENCECLASSIC SOFA 98RH AEGEANCOFFEE TABLE40" X 30"RHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISE RHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISE RHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISERHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISE RHALUMINUM SIDETABLE20 X 20RHMESA ALUMINUM CHAISE RHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISE RHALUMINUM SIDETABLE20 X 20RHMESA ALUMINUM CHAISERHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUM INUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUM INUM CHAISERHALUMINUM SIDETABLE20 X 20RHALUMINUM SIDETABLE20 X 20 RHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHALUMINUM SIDETABLE20 X 20RHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUM INUM CHAISERHMESA ALUMINUM CHAISERHMESA ALUM INUM CHAISERHALUMINUM SIDETABLE20 X 20RHALUMINUM SIDETABLE20 X 20RHMESA ALUMINUM CHAISERHALUMINUM SIDETABLE20 X 20RHMESA ALUM INUM CHAISERHMESA ALUM INUM CHAISERHMESA ALUM INUM CHAISERHMESA ALUM INUM CHAISERHMESA ALUM INUM CHAISERHMESA ALUM INUM CHAISERHALUMINUM SIDETABLE20 X 20RH ALUMINUM SIDETABLE20 X 20RHALUMINUM SIDETABLE20 X 20JBJBBUILDING 2TYPE 02BUILDING 5TYPE 02BUILDING 4TYPE 02BUILDING 3TYPE 01BUILDING 1TYPE 01Typical Site Lighting Pole Base Detail3Scale: NoneTypical Site Lighting/Fixture Handhole Detail2Scale: NoneBCDHGEAFDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:37 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE0.02Electrical SiteLighting andPower Plan02-06-2026 PERMIT REVISIONSE LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"S2LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"CCCCCCCCCCCCtCtCtCCCCS2LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"BUILDING T01 FRONT ELEVATIONScale: 1" = 20'-0"1BUILDING T01 REAR ELEVATIONScale: 1" = 20'-0"2BUILDING T01 SIDE ELEVATION AScale: 1" = 20'-0"3BUILDING T01 SIDE ELEVATION BScale: 1" = 20'-0"4Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:41 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE0.03Electrical BuildingType 1 LightingElevations BUILDING T02 FRONT ELEVATIONScale: 1" = 20'-0"1BUILDING T02 REAR ELEVATIONScale: 1" = 20'-0"2BUILDING T02 SIDE ELEVATION AScale: 1" = 20'-0"3BUILDING T02 SIDE ELEVATION BScale: 1" = 20'-0"4LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"S1LEVEL 1 T.O.S0' - 0"T.O PLATE41' - 0 3/4"LEVEL 2 T.O DECK10' - 7 7/8"LEVEL 3 T.O. DECK21' - 3 3/4"LEVEL 4 T.O. DECK31' - 11 5/8"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:42 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE0.04Electrical BuildingType 2 LightingElevations LEVEL 1 T.O.S0' - 0"CLUB T.O.P.10' - 6"LEVEL 1 T.O.S0' - 0"CLUB T.O.P.10' - 6"BUILDING CLUBHOUSE BACK ELEVATIONScale: 1" = 20'-0"1BUILDING CLUBHOUSE SIDE ELEVATIONScale: 1/8"=1'-0"3LEVEL 1 T.O.S0' - 0"CLUB T.O.P.10' - 6"BUILDING CLUBHOUSE FRONT ELEVATIONScale: 1" = 20'-0"2Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:42 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE0.05Electrical BuildingClubhouse LightingElevations UPSTAIR ASTAIR BRISER T.SVEST.E.C.R.T.S.T.S T.S VEST.IDFELEV.Type 1 - Building 1&3 - Level 1 - Lighting1Scale: 1/8"=1'-0"UPSTAIR ASTAIR BRISER T.SVEST.E.C.R.T.S.T.S T.S VEST.IDFELEV.ELEV.Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:48 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.1.1Building Type 1Level 1Lighting Plan1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE ELEV.MECH.STAIR ASTAIR BType 1 - Building 1&3 - Level 2 - Lighting1Scale: 1/8"=1'-0"ELEV.Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:49 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.1.2Building Type 1Level 2Lighting Plan1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE MECH.STAIR ASTAIR BELEV.Type 1 - Building 1&3 - Level 3 - Lighting1Scale: 1/8"=1'-0"ELEV.Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:51 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.1.3Building Type 1Level 3Lighting Plan1/8" = 1'-0" B214021402A214131413A214111411A214141414A214121412A114061406A114041404B214161416A114031403A114051405B014101410B114091409B114071407B114081408STAIR ASTAIR BC1-G214011401C114151415BDAS.P.S.P.ELEV.S.P.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.Type 1 - Building 1&3 - Level 4 - Lighting1Scale: 1/8"=1'-0"+9'-0"AFFELEV.+8'-0"AFF+9'-0"AFF+9'-0"AFFCEMCEMCEMCEMFECCEMFECCEMCEMFECFECFECDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:52 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.1.4Building Type 1Level 4Lighting Plan1/8" = 1'-0" B221152115A121132113A121112111A321092109A221072107A221052105A321032103B221012101B221022102A221062106A321042104A121122112A121142114B221162116B021102110VEST.RISER E.C.R.IDFSTAIR CSTAIR DELEV.A2-G221082108D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.S.P.S.P.F.E.C.D.S.D.S.F.E.C.F.E.C.F.E.C.T.S.Type 2 - Building 2,4,5 Level 1 - Lighting1Scale: 1/8"=1'-0"CEMFECELEV.CEMCEMCEMCEMCEMCEMCEMFECFECCEMDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:57 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.2.1Building Type 2Level 1Lighting Plan1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B222022202B222162216B222152215B022102210B222012201A222072207A222052205A322032203A322042204A222062206STAIR CSTAIR DT.S.ELEV.A2-G222082208A122122212A122112211A122132213A122142214S.P.S.P.B1-G222092209F.E.C.F.E.C.F.E.C.F.E.C.ELEV.Type 2 - Building 2,4,5 Level 2 - Lighting1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:58 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.2.2Building Type 2Level 2Lighting Plan1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B223012301A323032303A223052305A223072307A123112311A123132313B223152315STAIR CSTAIR DIDFB223022302A323042304A223062306A223082308B023102310A123122312A123142314B223162316ELEV.B1-G223092309S.P.S.P.F.E.C.F.E.C.F.E.C.F.E.C.ELEV.Type 2 - Building 2,4,5 Level 3 - Lighting1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:13:59 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.2.3Building Type 2Level 3Lighting Plan1/8" = 1'-0" B224012401A324032403A224052405A224072407A124112411A124132413B224152415B224162416A124142414A124122412B024102410A224082408A224062406A324042404B224022402T.S.STAIR DSTAIR CB1-G224092409S.P.S.P.ELEV.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.CEMCEMCEMCEMCEMFECFECFECFECCEMCEMType 2 - Building 2,4,5 Level 4 - Lighting1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:00 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE1.2.4Building Type 2Level 4Lighting Plan1/8" = 1'-0" VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G METALKITCHEN SINK FAUCETSPURISTK-7505CM-335Tread Mill Tread Mill Tread Mill Recumbent Bike ProStep Row PLR-950PL-206P-5500P-4300F.D.SCREENING111COURTYARD113LOBBY102CO WORKING110ASST MGR106MGR105LEASING103CLOSING104CLOSING107WORKROOM108IT/AV109PACKAGE114FITNESS115MAIL122WOMEN117MEN118FRONT PORCH101PHONE ROOM120PHONE ROOM120Clubhouse Level 1 Lighting Plan1Scale: 1/4"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:08 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"CLUBHOUSE -LEVEL 1 LIGHTINGPLANE1.3.1H.A.A.02-06-2026 PERMIT REVISIONSE UPB211021102A311081108A211141114B211161116C111011101A311071107B111091109A211131113C111151115A211121112A111061106A111051105A111041104A111031103STAIR ASTAIR BRISER T.SVEST.E.C.R.T.S.T.S T.S VEST.IDFELEV.D.S.B011101110A2-G211111111D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.S.P.S.P.W3.1aW3.1aF.E.C.F.E.C.F.E.C.F.E.C.1Scale: 1/8"=1'-0"Type 1 - Building 1& 3 - Level 1 - PowerDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:15 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE T01LEVEL 1POWER PLANE2.1.1H.A.A.02-06-2026 PERMIT REVISIONSE B212021202A112041204A112061206B112081208B012101210A212121212B212161216C112151215A2-G212111211B112091209C112011201A112051205B112071207A212131213A212141214ELEV.MECH.STAIR ASTAIR BCANOPYBELOWCANOPY BELOWCANOPYBELOWS.P.S.P.A112031203CANOPY BELOW4" ROOFDRAINS4" ROOF DRAINS4" ROOFDRAINS4" ROOFDRAINSF.E.C.F.E.C.F.E.C.F.E.C.Type 1 - Building 1& 3 - Level 2 - Power1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:16 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE T01LEVEL 2POWER PLANE2.1.2H.A.A.02-06-2026 PERMIT REVISIONSE B213021302C113011301A213131313A213111311A213141314A213121312A113061306A113041304B213161316A113031303A113051305C113151315B013101310B113091309B113071307B113081308MECH.STAIR ASTAIR BS.P.S.P.ELEV.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.1Scale: 1/8"=1'-0"Type 1 - Building 1& 3 - Level 3 - PowerDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:18 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE T01LEVEL 3POWER PLANE2.1.3H.A.A.02-06-2026 PERMIT REVISIONSE B214021402A214131413A214111411A214141414A214121412A114061406A114041404B214161416A114031403A114051405B014101410B114091409B114071407B114081408STAIR ASTAIR BC1-G214011401C114151415BDAELEV.1Scale: 1/8"=1'-0"Type 1 - Building 1& 3 - Level 4 - PowerDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:19 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"BUILDING TYPE T01LEVEL 4POWER PLANE2.1.4H.A.A.02-06-2026 PERMIT REVISIONSE PSPSPS6:126:124:12 4:12 6:126:126:12 6:12 6:126:124:12 6:12 4:126:126:124:126:126:126:126:126:126:126:126:12 6:12 6:12 4:12 6:121501PSD.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.1Scale: 1/8"=1'-0"Type 1 - Building 1& 3 - Roof - PowerAPPROXIMATE LOCATION OF LIGHT FIXTURES.COORDINATE WITH MECHANICAL EQUIPMENT ANDMOUNTING OF FIXTURES. REFER TO LIGHT ANDRECEPTACLE DETAIL FOR ADDITIONALINFORMATION. (TYPICAL)APPROXIMATE LOCATION OF POWER CONNECTIONFOR RADON SYSTEM. COORDINATE WITHPLUMBING CONTRACTOR PRIOR TO ROUGH INAPPROXIMATE LOCATION OF POWER CONNECTIONFOR RADON SYSTEM. COORDINATE WITHPLUMBING CONTRACTOR PRIOR TO ROUGH INAPPROXIMATE LOCATION OF POWER CONNECTIONFOR RADON SYSTEM. COORDINATE WITHPLUMBING CONTRACTOR PRIOR TO ROUGH INLADDER TO HATCH.SWITCH AT BASE OFROOF HATCHROOF WEATHERPROOF LIGHTING FIXTURE WITH GUARD(STONCO VWXL) OR APPROVED EQUAL#12/2 WITH GND. TYPE "SO"CABLE WITH SUITABLESLACK FOR HATCHOPERATIONTYPICAL DETAIL OF LIGHT FIXTURE AT ROOF HATCHNTSFUTURE SOLAR PANELSFUTURE SOLAR PANELSDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:20 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE T01ROOF LEVELPOWER PLANE2.1.5H.A.A. B221152115A121132113A121112111A321092109A221072107A221052105A321032103B221012101B221022102A221062106A321042104A121122112A121142114B221162116B021102110VEST.RISER E.C.R.IDFSTAIR CSTAIR DELEV.A2-G221082108D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.S.P.S.P.F.E.C.D.S.D.S.F.E.C.F.E.C.F.E.C.T.S.Type 2 - Building 2,4,5 - Level 1 - Power1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:27 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE 2LEVEL 1POWER PLANE2.2.1H.A.A.02-06-2026 PERMIT REVISIONSE B222022202B222162216B222152215B022102210B222012201A222072207A222052205A322032203A322042204A222062206STAIR CSTAIR DT.S.ELEV.A2-G222082208A122122212A122112211A122132213A122142214CANOPY BELOWCANOPY BELOWCANOPY BELOWS.P.S.P.MIRR.B1-G222092209MIRR.4" ROOFDRAINS4" ROOFDRAINS4" ROOF DRAINS4" ROOF DRAINSF.E.C.F.E.C.F.E.C.F.E.C.Type 2 - Building 2,4,5 - Level 2 - Power1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:28 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE 2LEVEL 2POWER PLANE2.2.2H.A.A.02-06-2026 PERMIT REVISIONSE B223012301A323032303A223052305A223072307A123112311A123132313B223152315STAIR CSTAIR DIDFB223022302A323042304A223062306A223082308B023102310A123122312A123142314B223162316ELEV.B1-G223092309S.P.S.P.F.E.C.F.E.C.F.E.C.F.E.C.Type 2 - Building 2,4,5 - Level 3 - Power1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:29 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE 2LEVEL 3POWER PLANE2.2.3H.A.A.02-06-2026 PERMIT REVISIONSE B224012401A324032403A224052405A224072407A124112411A124132413B224152415B224162416A124142414A124122412B024102410A224082408A224062406A324042404B224022402T.S.STAIR DSTAIR CB1-G224092409S.P.S.P.ELEV.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.Type 2 - Building 2,4,5 - Level 4 - Power1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:30 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE 2LEVEL 4POWER PLANE2.2.4H.A.A.02-06-2026 PERMIT REVISIONSE 6:126:124:12 4:12 6:12 6:12 4:12 4:126:126:126:126:12 6:126:126:124:12 6:126:12 6:126:126:126:126:124:12 6:126:126:126:121/4" / 12"1/4" / 12" 1/4" / 12"1/4" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/4" / 12" 1/4" / 12" 1/4" / 12" 1/4" / 12"ROOF ACCESSDOORWALKING PAD2501PSPSPSPSD.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.PLATFORM &CATWALK FORACCESSAC CONDENSERS ON RACKSType 2 - Building 2,4,5 - Roof - Power1Scale: 1/8"=1'-0"APPROXIMATE LOCATION OF LIGHT FIXTURES ANDRECEPTACLE. COORDINATE WITH MECHANICALEQUIPMENT. REFER TO DETAIL FOR ADDITIONALINFORMATION. (TYPICAL)APPROXIMATE LOCATION OF POWER CONNECTIONFOR RADON SYSTEM. COORDINATE WITHPLUMBING CONTRACTOR PRIOR TO ROUGH INAPPROXIMATE LOCATION OF POWER CONNECTIONFOR RADON SYSTEM. COORDINATE WITHPLUMBING CONTRACTOR PRIOR TO ROUGH INAPPROXIMATE LOCATION OF POWER CONNECTIONFOR RADON SYSTEM. COORDINATE WITHPLUMBING CONTRACTOR PRIOR TO ROUGH INFUTURE SOLAR PANELSFUTURE SOLAR PANELSDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:31 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE 2ROOF LEVELPOWER PLANE2.2.5H.A.A. VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G METALKITCHEN SINK FAUCETSPURISTK-7505CM-335Tread Mill Tread Mill Tread Mill RecumbentBikeProStep Row PLR-950PL-206P-5500P-4300VESTIBULEJANITORWOMENPHONE ROOMPHONE ROOMMENPACKAGEWORKROOMASST. MGR.MGR.FITNESSMAILSCREENINGHALLLEASINGCO WORKINGLOBBYRISER ROOMIT/AVF.D.WORKROOM108PACKAGE114ASST MGR106MGR105LEASING103CLOSING104CLOSING107SCREENING111LOBBY102CO WORKING110FITNESS115WOMEN117MEN118JANITOR116IT/AV109COURTYARD113OUTDOOR LOUNGE112MAIL122PHONE ROOM121PHONE ROOM120FRONT PORCH101FIRE SPKLR & RISER123HALL123Clubhouse Power Level 1 Plan1Scale: 1/4"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:38 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"CLUBHOUSE -LEVEL 1 POWERPLANE2.3.1H.A.A.02-06-2026 PERMIT REVISIONSE 10-BIKE_811010-BIKE_811010-BIKE_8110 10-BIKE_8110 8-BIKE_8118 8-BIKE_8118G1G1G1G1G1G11 HR RATEDATTIC ACCESS(LOCKED)D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.1 HR RATEDATTIC ACCESS(LOCKED)D.S.D.S.D.S.D.S.D.S.D.S.D.S.1/4" PER 12" MAX.Garage "A" Part Plan1Scale: 1/4"=1'-0"Garage "B" Part Plan2Scale: 1/4"=1'-0"Garage "C" Part Plan3Scale: 1/4"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:45 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"GARAGEELECTRICAL PARTPLANSE2.4.1H.A.A.02-06-2026 PERMIT REVISIONSE MAINTENANCEGOLF CART BAYPOOL SUPPLY CLOSETD.S.D.S.ADD INSULATION ATMAINTENANCE WALLSAND CEILING ABOVED.S.D.S.1 HR RATEDATTIC ACCESS(LOCKED)FLOORDRAIN-3/4 " T.O.DD.S.D.S.D.S.D.S.EYE WASHSTATIONVARIESSHELVINGVERIFY W/OWNERSHELVINGVERIFY W/OWNERUTILITY SINKRE: PLUMBINGVARIESVARIESSLOPE DOWN 3" SLOPE DOWN 3" SLOPE DOWN 3" SLOPE DOWN 3" SLOPE DOWN 3"SLOPE DOWN 3"SLOPE DOWN 3" 3 1/2" 3 1/2" 3 1/2" 3 1/2"3 1/2"3 1/2"3 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"3/4"3/4"3/4"3/4"3/4"STACKEDWASHER/DRYERFLOORDRAIN-3/4 " T.O.DVARIESVARIESVARIESVARIESVARIESVARIESD.S.Garage "D" Power Plan1Scale: 1/4"=1'-0"F1 HR RATEDATTIC ACCESS(LOCKED)D.S.D.S.D.S.3/4" 3 1/2" 3/4" 3/4" 3 1/2" 3/4"VARIES3/4" 3 1/2" 3/4" 3/4"3 1/2"3/4"3/4"3 1/2"3/4"3/4"3 1/2"3/4"D.S.D.S.D.S.DOG WASHW.H.D.S.DRYING BENCHF.D.F.D.1/4" / 12"1/4 3 1/2" SLOPE DOWN 3"SLOPE DOWN 3"SLOPE DOWN 3" SLOPE DOWN 3" SLOPE DOWN 3" SLOPE DOWN 3"VARIESVARIESVARIESVARIESVARIESVARIESD.S.Garage "E" Power Plan2Scale: 1/4"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:47 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"GARAGEELECTRICAL PARTPLANSE2.4.2H.A.A.02-06-2026 PERMIT REVISIONSE 10-BIKE_811010-BIKE_811010-BIKE_8110 10-BIKE_8110 8-BIKE_8118 8-BIKE_8118BIKE STORAGECAPACITY = 601 HR RATED ATTICACCESS(LOCKED)1 HR RATEDATTIC ACCESS(LOCKED)D.S.D.S.D.S.D.S.D.S.D.S.D.S.1/4" PER 12" MAX.Garage "H" Part Plan3Scale: 1/4"=1'-0"Garage "G" Part Plan2Scale: 1/4"=1'-0"Garage "F" Part Plan1Scale: 1/4"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:48 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"GARAGEELECTRICAL PARTPLANSE2.4.3H.A.A.02-06-2026 PERMIT REVISIONSE W W W W W WTrash Compactor Power Plan1Scale: 1/4"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:50 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"TRASHCOMPACTORPOWER PLANE2.4.4H.A.A.02-06-2026 PERMIT REVISIONSE UPB211021102A311081108A211141114B211161116C111011101A311071107B111091109A211131113C111151115A211121112A111061106A111051105A111041104A111031103STAIR ASTAIR BRISER T.SVEST.E.C.R.T.S.T.S T.S VEST.IDFELEV.D.S.B011101110A2-G211111111D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.S.P.S.P.W3.1aW3.1aF.E.C.F.E.C.F.E.C.F.E.C.Building 1 & 3 Type 1 - Level 1 - Fire Alarm1Scale: 1/8"=1'-0"E5.11Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:54 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T01LEVEL 1FIRE ALARM PLANE3.1.11/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B212021202A112041204A112061206B112081208B012101210A212121212B212161216C112151215A2-G212111211B112091209C112011201A112051205B112071207A212131213A212141214ELEV.MECH.STAIR ASTAIR BCANOPYBELOWCANOPY BELOWCANOPYBELOWS.P.S.P.A112031203CANOPY BELOW4" ROOFDRAINS4" ROOF DRAINS4" ROOFDRAINS4" ROOFDRAINSF2F.E.C.F.E.C.F.E.C.F.E.C.Building 1 & 3 Type 1 - Level 2 - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:55 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T01LEVEL 2FIRE ALARM PLANE3.1.2H.A.A.1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B213021302C113011301A213131313A213111311A213141314A213121312A113061306A113041304B213161316A113031303A113051305C113151315B013101310B113091309B113071307B113081308MECH.STAIR ASTAIR BS.P.S.P.ELEV.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.Building 1 & 3 Type 1 - Level 3 - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:57 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T01LEVEL 3FIRE ALARM PLANE3.1.3H.A.A.1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B214021402A214131413A214111411A214141414A214121412A114061406A114041404B214161416A114031403A114051405B014101410B114091409B114071407B114081408STAIR ASTAIR BC1-G214011401C114151415BDAS.P.S.P.ELEV.S.P.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.Building 1 & 3 Type 1 - Level 4 - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:58 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T01LEVEL 4FIRE ALARM PLANE3.1.4H.A.A.1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE PSPSPSPSBuilding Type 1 - Roof - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:14:59 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T01ROOF LEVELFIRE ALARM PLANE3.1.5H.A.A.1/8" = 1'-0" B221152115A121132113A121112111A321092109A221072107A221052105A321032103B221012101B221022102A221062106A321042104A121122112A121142114B221162116B021102110VEST.RISER E.C.R.IDFSTAIR CSTAIR DELEV.A2-G221082108D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.S.P.S.P.F.E.C.D.S.D.S.F.E.C.F.E.C.F.E.C.T.S.Building 2,4, & 5 Type 2 - Level 1 - Fire Alarm1Scale: 1/8"=1'-0"E5.11Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:03 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/8" = 1'-0"BUILDING TYPE T02LEVEL 1FIRE ALARM PLANSE3.2.1H.A.A.02-06-2026 PERMIT REVISIONSE B222022202B222162216B222152215B022102210B222012201A222072207A222052205A322032203A322042204A222062206STAIR CSTAIR DT.S.ELEV.A2-G222082208A122122212A122112211A122132213A122142214S.P.S.P.B1-G222092209F.E.C.F.E.C.F.E.C.F.E.C.Building 2,4, & 5 Type 2 - Level 2 - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:04 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T02LEVEL 2FIRE ALARM PLANSE3.2.2H.A.A.1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B223012301A323032303A223052305A223072307A123112311A123132313B223152315STAIR CSTAIR DIDFB223022302A323042304A223062306A223082308B023102310A123122312A123142314B223162316ELEV.B1-G223092309S.P.S.P.F.E.C.F.E.C.F.E.C.F.E.C.Building 2,4, & 5 Type 2 - Level 3 - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:05 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T02LEVEL 3FIRE ALARM PLANSE3.2.3H.A.A.1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE B224012401A324032403A224052405A224072407A124112411A124132413B224152415B224162416A124142414A124122412B024102410A224082408A224062406A324042404B224022402T.S.STAIR DSTAIR CB1-G224092409S.P.S.P.ELEV.F.E.C.F.E.C.F.E.C.F.E.C.F.E.C.Building 2,4, & 5 Type 2 - Level 4 - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:06 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T02LEVEL 4FIRE ALARM PLANSE3.2.4H.A.A.1/8" = 1'-0"02-06-2026 PERMIT REVISIONSE 6:126:124:12 4:12 6:12 6:12 4:12 4:126:126:126:126:12 6:126:126:124:12 6:126:12 6:126:126:126:126:124:12 6:126:126:126:121/4" / 12"1/4" / 12" 1/4" / 12"1/4" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/2" / 12"1/4" / 12" 1/4" / 12" 1/4" / 12" 1/4" / 12"ROOF ACCESSDOORWALKING PAD2501PSPSPSPSD.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.D.S.PLATFORM &CATWALK FORACCESSAC CONDENSERS ON RACKSBuilding 2,4, & 5 Type 2 - Roof - Fire Alarm1Scale: 1/8"=1'-0"Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:07 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCBUILDING TYPE T02ROOF LEVELFIRE ALARM PLANSE3.2.5H.A.A.1/8" = 1'-0" VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G VITREOUS CHINABATHROOM SINKCAXTONK-2210-G METALKITCHEN SINK FAUCETSPURISTK-7505CM-335Tread Mill Tread Mill Tread Mill RecumbentBikeProStep Row PLR-950PL-206P-5500P-4300F.D.WORKROOM108PACKAGE114ASST MGR106MGR105LEASING103CLOSING104CLOSING107SCREENING111LOBBY102CO WORKING110FITNESS115WOMEN117MEN118JANITOR116IT/AV109COURTYARD113OUTDOOR LOUNGE112MAIL122PHONE ROOM121PHONE ROOM120FRONT PORCH101FIRE SPKLR & RISER123HALL123Clubhouse Fire Alarm Level 1 Plan1Scale: 1/4"=1'-0"SCREENING111COURTYARD113LOBBY102CO WORKING110ASST MGR106MGR105LEASING103CLOSING104CLOSING107WORKROOM108IT/AV109PACKAGE114FITNESS115MAIL122WOMEN117MEN118FRONT PORCH101PHONE ROOM120VSVSVSPHONE ROOM120VSDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:13 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1/4" = 1'-0"CLUBHOUSE -LEVEL 1 FIREALARM PLANE3.3.1H.A.A.02-06-2026 PERMIT REVISIONSE Power Riser Diagram - Building 11SCHEDULE OF MODULAR METER CENTERS 120/208V, 3PH, 4WLEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSLOAD CENTER SER FEEDER SCHEDULE (ALUMINUM)E4.1.ElectricalBuilding #1 PowerRiser DiagramS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:16 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC1 02-05-2026 RFI #6 Power Riser Diagram - Building 21SCHEDULE OF MODULAR METER CENTERS 120/208V, 3PH, 4WLEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSLOAD CENTER SER FEEDER SCHEDULE (ALUMINUM)E4.2ElectricalBuilding #2 PowerRiser DiagramS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:16 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC Power Riser Diagram - Building 31SCHEDULE OF MODULAR METER CENTERS 120/208V, 3PH, 4WLEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSLOAD CENTER SER FEEDER SCHEDULE (ALUMINUM)E4.3ElectricalBuilding #3 PowerRiser DiagramS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:17 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC Power Riser Diagram - Building 41SCHEDULE OF MODULAR METER CENTERS 120/208V, 3PH, 4WLEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSLOAD CENTER SER FEEDER SCHEDULE (ALUMINUM)E4.4ElectricalBuilding #4 PowerRiser DiagramS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:18 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE Power Riser Diagram - Building 51SCHEDULE OF MODULAR METER CENTERS 120/208V, 3PH, 4WLEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSLOAD CENTER SER FEEDER SCHEDULE (ALUMINUM)E4.5ElectricalBuilding #5 PowerRiser DiagramS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:18 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE Power Riser Diagram - Building 6 Clubhouse/Leasing1LEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSElectric Service Shunt Trip Detail E4.6ElectricalClubhouse PowerRiser DiagramS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:19 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE Fire Alarm Riser Bldg #1 thru #51Scale: None3Scale: NoneBuilding #5 - BDA Wiring DiagramFire/Smoke Damper Wiring DiagramScale: NONE2Building #1 - BDA Wiring DiagramE4.7ElectricalBuilding Type 1 & 2Fire Alarm RiserS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:21 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE Clubhouse/Leasing Fire Alarm Riser Diagram Scale: No Scale1E4.8ElectricalBuilding 6Fire Alarm RiserS. Januskis40629Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:22 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE 1NOTESLEGEND & EQUIPMENT SPECIFICATIONSSIZING OF THE TBCBldg Type T01 & T02 Tele-Data Riser DiagramE4.9Building Type T01& T02 Tele-DataRiserDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:24 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC Building 1 thru 5 - Typical Elevator Machine Rm & Pit Part Plan1Scale: 1/4"=1'-0"T.S.T.S ELEV.1102ELEV.E5.1ElectricalElevator MachineRoom Part PlansDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:27 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE PCPCMECH PAN.W.I.C.BATH 2KITCHENENTRYBEDROOM 2BEDROOM 1LIVING/DININGW.I.C.BATH 1LIN.TYPICAL DESK SWITCHScale: NONEBATHROOM COMBO SWITCHScale: NONEScale: NONECATEGORY 6 CABLE + COAXIAL CABLE +POWER OUTLETSACBELECTRICAL UNIT TYPE A11Scale: 1/4"=1'-0"ELECTRICAL UNIT TYPE A22Scale: 1/4"=1'-0"GFIGFIScGFISlPCScale: 1/4"=1'-0"ELECTRICAL UNIT - TYPE A2G23ELECTRICAL UNIT TYPE B04Scale: 1/4"=1'-0"GFI15CDSBSSSm1/4" = 1'-0"ELECTRICAL UNITPLANSE5.2H.A.A.Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:31 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE PCW.I.C.W.I.C.BATH 1BATH 2ENTRYKITCHENPAN.BEDROOM 2BEDROOM 1LIVING/DININGCOATS MECH LIN. LIN.W.I.C.W.I.C.BATH 1BATH 2BEDROOM 2BEDROOM 1COATS PAN.ENTRYKITCHENLIVING/DININGMECHLIN.LIN.Scale: 1/4"=1'-0"ELECTRICAL UNIT - TYPE B1Scale: 1/4"=1'-0"ELECTRICAL UNIT - TYPE B2ELECTRICAL UNIT TYPE A31Scale: 1/4"=1'-0"ELECTRICAL UNIT TYPE B1G23Scale: 1/4"=1'-0"ScSc24PCLCSc1/4" = 1'-0"ELECTRICAL UNITPLANSE5.3H.A.A.Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:32 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE 02-06-2026 PERMIT REVISIONSE Scale: 1/4"=1'-0"ELECTRICAL UNIT - TYPE C1Sc1PCScale: 1/4"=1'-0"ELECTRICAL UNIT - TYPE C1G22S3dISScDBPB1/4" = 1'-0"ELECTRICAL UNITPLANSE5.4H.A.A.Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:32 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFC02-06-2026 PERMIT REVISIONSE Hanover Hyannis IIRevised 2/13/26Light Fixture ScheduleTypeFixtureLocation / DescriptionLampingUNITSUAWAC FM616-930-WTLIGHTING THROUGH-OUT UNITLEDUBMaxim 55571WTSNBALCONY SCONCELED 15wUEWAC FM616-930-WTSHOWER/TUB SURFACE MOUNTLEDUFTRG 1023NPCWC-BN/WA with WC6CEILING FAN WITH LIGHT KIT & FAN SPEEDCONTROL2-SCREW IN 9w LEDUV3Rayo RV6613BNVANITY 3-LIGHT3-SCREW IN 9w LEDUV4Rayo RV6614BNVANITY 4-LIGHT4-SCREW IN 9w LEDPCTRG LED-30099 PCH-WHDISK IN UTILITY CLOSET WITH PULLCHAIN16w LEDBREEZEWAYCCWAC FM616-930-WTCorridor LED Faux Recessed15w LEDCEM1/2MULE TSR-WDAMP RATED HO EMERGENCY FLOODLEDCEM3MULE TSR-HO-WDAMP RATED VHO EMERGENCY FLOODLEDCM1Globalux ECW-4-36-MV-MCTMaintenance / Storage Wrap36w LEDECNora NCH3-4L1C12 / NC-41L130DMPWRecessed Downlight11w LEDEC1Nora NCH3-4L1C12-EM / NC-41L130DMPWRecessed Downlight with Battery Backup11w LEDPCTRG LED-30099 PCH-WHMAINTENANCE CLOSET WITH PULLCHAIN16w LEDClubhouseFixtureLocation / DescriptionLampingABGlobalux ECW-2-18-MV-MCTMechanical / Closet18w LED WrapAB-1Nora NPTCB-E22-30AW2X2 Recessed in Workroom & Package Room15w LEDACAlloyLED Primaline 3 Wet Location with OutdoorRated Transformers for installationLinear uplight in Amentiy Outdoor Space3w LED per LFAENora NCH3-4L1C12 / NC-41L130DMPWRecessed Downlight11w LEDAE2Nora NCH3-4L1C12 / NC-41L130BZRecessed Downlight11w LEDAF-1MinkaAire Roto Flush F644L-WHFDogwash Fan16w LEDAP-1Maxim Vesper 26034SWSBRBKClubroom Vaulted Ceiling Pendant9w LED A-Lamp DimmableAP-2Maxim Helsinki 11436NABScreening Lounge3 - 9w LED A-Lamp DimmableAP3Maxim Lighting Veritas 15162CHB-ChestnutBrownMailroom Pendants9w LED A-Lamp DimmableAP3-AltVisual Comfort Wellfleet Wide Cone PendantCP1311MBKBBSAlternate Mailroom PendantLED 8w ST19 ClearAP4Maxim Nordic 11358TNBKLeasing Managers OfficesLED 8w ST19 ClearAP5Dainolite ATL-445HP-MBLeasing Concierge Desk5 - LED4G9/30K/W/D - 4w eaAP6Kuzco Bruni 32, black PD24732-BKFitness45w LEDAP7Cedar & Moss Alto Rod 12" - Black / White GlassFront Porch Pendant (Verify stem length prior toordering)9w LED A-Lamp DimmableAS1Visual Comfort Albertine AEW1032MBKBurnished Brass with Black ConesZoom Room Sconces2 - 5w LED Candelabra TorpedoAS1 AltKalco 310422BVBAlternate Zoom Room Sconces2 - 5w LED Candelabra TorpedoAS2Visual Comfort Chalmette Medium JN2300GRestroom Sconces2 - 2.5w E12 T6 LED LampAS3Chelsom Solar SL/11/W1Screening Lounge Sconces8w LED 2700kATAlloyLED Primaline 3Cove Lighting Throughout3w PLFAUMAXIM Counter MaxUnder Cabinet in WorkroomLED - 6w PLFAXEELP ER-EDGE-1/3-BNLobby Exit LightsLEDAWNora NCH3-4L1C12 / NC-46L130DMPWRecessed Wallwasher11w LEDEBBDual-Lite PG Series - Finish TBDClubhouse Exterior Emergency Lights - Wall MountLEDEBCDual-Lite EV4RClubhouse Emergency Lights - Ceiling MountLEDBUILDING / SITE LIGHTINGEAMaxim 55577WTSNExterior Sconce at Clubhouse28w LEDEBMaxim 55573WTSNExterior Sconce at Breezeway Entrance23w LEDECNora NCH3-4L1C12/EM / NC3-41L130FDMPWExterior Recessed Downlight with Emergency13W LEDEWEnvision WPFC-5P80-TRI-BZ-PCBuilding Wallpack47W LEDEZWAC (2) 5212-120VAC-3000K-BZWITH DualMount WallplateDouble LED Bullet Light on Building2-31w LEDEC1Compass #CUSO-120-3000Exterior egress Emergency Downlight withEmergency13W LEDGARAGE/CARPORT LIGHTINGGASatco 62-1820Garage Ceiling with Motion Sensor16w LEDGMGlobalux ECW-4-36-MV-MCTMaintenance Wrap36w LED WrapGSMaxim 55571WTSNGarage Sconce15w LEDG-SM1Lumato 2S-ID Verify Mounting and FinishBike Storage6.9w PLFLANDSCAPE LIGHTINGLAEnvison PST-3P75-TRI-BZ-UNV atop 16' RSSPolePost Top Parking Area PoleMax 150w LEDLBEnvison PST-3P150-TRI-BZ-UNV atop 16' RSSPolePost Top Parking Area PoleMax 150w LEDLCWAC (2)5212-120VAC-3000-BZ with SingleMount Wall PlateDouble Building Floodlights(2)Max 31w LEDLDEnvison WPFC-5P80-TRI-BZWallpack on BuildingsMax 80w LEDLGLightcraft E26 Arch String BK-E26 with S14 LEDLamp and Pyramid Bistro ShadeSTRING LIGHTS WITH DS HOODS1.4w LED S14 Filament LampLHRAB BRISK17FA-20Trash Compactor Area20w LEDEPEnvision ARL3-5P150-TRI-BZ-UNV/ARL35A atopSSP20Parking Lot Light on Pole (1, 2, 3 or 4 Heads)106w LED Per HeadRESIDENTIAL CORRIDORSLIGHTING SYSTEM CONTROLS SEQUENCE OF OPERATIONS (2021 IECC)AREA ROOM SPACEFUNCTION/OPERATION/STRATEGIESSTAIRSSTORAGE ROOMSOPEN OFFICEPUBLIC CORRIDORSUTILITY ROOMS, ELEC, MECH, TELE/DATA ROOMSLARGE STORAGE ROOMS AND MAINTENANCE SHOPS100% OCCUPANCY SENSOR AUTO ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED AFTER 20MINS. MANUAL ON/OFF CONTROL DEVICE. WHERE >150W IN DAYLIGHT AREA, USE CONTINUOUSDIMMING DAYLIGHT RESPONSE CONTROL AND MANUAL DIMMER IN LIEU OF ON/OFF DEVICE.LOBBYFACADE LIGHTINGPARKING LIGHTINGPEDESTRIAN WALKWAYGENERAL1.LOSS OF NORMAL POWER SHALL BRING LIGHTING TO FULL ON MODE FOR EMERGENCY (E) CIRCUITS. EMERGENCY LIGHTING CONTROLLED WITH NORMAL ZONES SHALL BE PROVIDED WITH UL924 BY-PASS RELAY.2.PROVIDE PHASE DIMMING ADAPTORS FOR TRIAC AND ELV LOADS AS REQUIRED.3.ALL ROOM CONTROLLERS WITHIN AN AREA SHALL BE INTERCONNECTED WITH THE INTENT FOR ALL CONTROLLERS TO FUNCTION SIMULTANEOUSLY. REFER TO FLOOR PLANS FOR SWITCH LEG QUANTITIES.4.QUANTITY OF RELAYS AND ROOM CONTROLLERS SHALL BE PROVIDED AS REQUIRED TO COTNROLS THE ZONES INDICATED ON THE PLANS.5.RECEPTACLE CONTROL: TURN ON/OFF FROM SENSORS WHEN UNOCCUPIED AFTER 20 MINS.6.FULL AUTOMATIC ON CONTROLS SHALL BE PERMITTED IN CORRIDORS, STAIRWAYS, LOBBIES, RESTROOMS, READING AND WHERE MANUAL OPERATIONS ENDANGERS SAFETY OR SECURITY. ALL OTHER AREAS SHALL BE MANUAL ON OR PARTIAL TO COMPLY WITHIECC.7.AUTOMATIC DAYLIGHT RESPONSIVE CONTROL REQUIRED WHERE ≥100W OF GENERAL LIGHTING IN TOPLIGHT OR PRIMARY AND SECONDARY SIDELIGHT AREA. SECONDARY SIDELIGHT AREA CONTROLS REQUIRED WHEN PRIMARY AND SECONDARY IS >300W. (C405.2.4)OCCUPANCY SENSORTIME-SWITCH(CLOCK)DAYLIGHTHARVESTMANUAL CONTROLDIMMING/REDUCTIONAUTO ON MANUAL ON (VACANCY) AUTO OFF (20 MIN MAX) AUTO PARTIAL OFF (20 MIN MAX) TIME ON TIME OFF ASTRONOMICAL OR PHOTOCELL ON/OFF AUTO CONTINUOUS DIMMING WITH OFF LIGHTING CONTROLRELAY PANEL (LCP)AUTO SHUTOFF PARTIAL ON/MANUAL ON DAYLIGHT RESPONSIVE CONTROL AUTO PARTIAL OFF (20 MIN MAX) MANUAL ON/OFF SWITCH MANUAL DIMMER SWITCH DISPLAY, ACCENT, TASK CONTROL AUTO RECEPTACLE CONTROL MANUAL LIGHT REDUCTION CONTROL MANUAL CONTINUOUS DIM CONTROL 100% AUTO ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED/VACANT AFTER 20 MINS.50% AUTO ON, MANUAL CONTROL ON/OFF CONTROL, OCCUPANCY SENSOR TURN OFF WHENUNOCCUPIED.OFFICES50% AUTO ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED/VACANT AFTER 20 MINS. AUTOON/OFF CONTROL OF 50% RECEPTACLE PLUG LOAD(≤ 600SF CONTROL ZONES)100% OCCUPANCY SENSOR AUTO ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED AFTER 20MINS. MANUAL ON/OFF CONTROL DEVICE. WHERE >150W IN DAYLIGHT AREA, USE CONTINUOUSDIMMING DAYLIGHT RESPONSE CONTROL AND MANUAL DIMMER IN LIEU OF ON/OFF DEVICE.100% AUTO ON, OCCUPANCY SENSOR AUTO OFF. REDUCE TO 80% WHEN UNOCCUPIED AFTER20 MINS. MANUAL ON/OFF CONTROL DEVICE. WHERE ≥150W IN DAYLIGHT AREA, USECONTINUOUS DIMMING DAYLIGHT RESPONSE CONTROL AND MANUAL DIMMER. AUTO ON/OFFCONTROL OF 50% RECEPTACLE PLUG LOADMANUAL ON, OCCUPANCY SENSOR AUTO OFF, MANUAL ON/OFF DEVICE. MAXIMUM 2 HOUROVERRIDE CAPABILITY. OCCUPANCY SENSOR AUTO OFF AFTER 20 MINS.50% AUTO ON, MANUAL CONTROL ON/OFF CONTROL, OCCUPANCY SENSOR TURN OFF WHENUNOCCUPIED AFTER 20 MINS.100% AUTO ON, OCCUPANCY SENSOR AUTO OFF WHEN UNOCCUPIED/VACANT. MANUAL ON/OFFCONTROL DEVICE. SEE NOTE #7FITNESS/GYM100% MANUAL ON, OCCUPANCY SENSOR AUTO OFF WHEN UNOCCUPIED/VACANT. MANUALON/OFF CONTROL DEVICE.MAILROOM/PACKAGING100% AUTO ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED/VACANT AFTER 20 MINS.READING/SCREENING50% AUTO ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED/VACANT AFTER 20 MINS.DIMMING DAYLIGHT RESPONSE CONTROL NOT MORE THAN 15% IN DAYLIGHT ZONE.RAISE/LOWER SCENE CONTROLLER.LEASINGMANUAL ON, REDUCED PARTIAL TO 50% WHEN UNOCCUPIED/VACANT AFTER 20 MINS. AUTOON/OFF CONTROL OF 50% RECEPTACLE PLUG LOAD.AUTO ON WITH ASTRONOMICAL TIME SWITCH (CLOCK) OR PHOTOCELL. PROGRAMMED OFF NOLATER THAN ONE HOUR AFTER BUSINESS CLOSE AND NO EARLIER THAN ONE HOUR BEFOREBUSINESS OPEN. DAWN AUTO OFF WITH TIME SWITCH (CLOCK)100% AUTO ON WITH ASTRONOMICAL TIME SWITCH (CLOCK) OR PHOTOCELL. OCCUPANCYSENSOR PARTIAL AUTO OFF ≥ 50%. DIM TO 30% WHEN UNOCCUPIED IS DETECTED.PROGRAMMED NO LATER THAN MIDNIGHT OR BUSINESS CLOSE AND NO EARLIER THAN 6 A.M.OR BUSINESS OPEN. DAWN AUTO OFF WITH ASTRONOMICAL TIME SWITCH OR PHOTOCELL.LIGHTING 20' FROM BUILDING TO AUTOMATICALLY REDUCE LIGHT LEVELS BY 50% VIA DAYLIGHTSENSOR.AUTO ON WITH ASTRONOMICAL TIME SWITCH (CLOCK) OR PHOTOCELL. OCCUPANCY SENSORPARTIAL AUTO OFF ≥ 50% OR AUTOMATICALLY OFF WHEN SUFFICIENT DAYLIGHT IS CENSOREDOR SET SCHEDULE. PROGRAMMED NO LATER THAN MIDNIGHT OR BUSINESS CLOSE AND NOEARLIER THAN 6 A.M. OR BUSINESS OPEN. DAWN AUTO OFF WITH ASTRONOMICAL TIME SWITCHOR PHOTOCELL. LIGHTING 20' FROM BUILDING TO AUTOMATICALLY REDUCE LIGHT LEVELS BY50% VIA DAYLIGHT SENSOR.PARKING GARAGE100% AUTO ON, OCCUPANCY SENSOR OR TIME SWITCH CONTROL. REDUCED PARTIAL TO 30%WHEN VACANT, AUTO OFF OR PROGRAMMED SHUTOFF.WORKROOM50% AUTO ON, OCCUPANCY SENSOR AUTO OFF. MANUAL ON/OFF CONTROL. AUTO ON/OFFCONTROL OF 50% RECEPTACLE PLUG LOAD.PHONE ROOMAUTO ON 50%, OCCUPANCY SENSOR AUTO OFF; MANUAL ON/OFF CONTROL.JANITOR100% MANUAL ON, OCCUPANCY SENSOR AUTO OFF WHEN UNOCCUPIED/VACANT. MANUALON/OFF CONTROL DEVICEDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:36 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE6.1Electrical LightingSchedules BRANCH CIRCUITS SCHEDULESPECIAL PURPOSE RECEPTACLE SCHEDULELEGEND OF 3-PHASE FEEDER SIZES - ALUMINUM CONDUCTORSTYPICAL LOAD CENTER SCHEDULETYPICAL HC LOAD CENTER SCHEDULEDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:39 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE6.2ElectricalSchedules Date Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:40 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE6.3ElectricalMechanicalSchedules TYPICAL NAMEPLATE DETAILREQUIRED CLEARANCE FOR ELECTRICAL EQUIPMENTNumberDescriptionLocationLOCATIONTYPE OF WIRENOTESGENERATOR CONTROLS AND WIRING DETAILNTSNTSNTSTYPICAL PANEL NAMEPLATE LOCATIONSTYPICAL DUCTBANK TERMINATION DETAILBUILDING GROUNDING ELECTRODE SYSTEM DETAILTYPICAL DETAIL FOR LABELING SYSTEM ON DEVICE PLATES2-WAY COMMUNICATION RISER DIAGRAMROOF TOP MECHANICAL EQUIPMENT LIGHTING &RECEPTACLE DETAILSEPARATELY DERIVED GENERATOR SYSTEM GROUNDING DETAILNTSNTSNTSNTSNTSNTSNTSFIRE PIT TIMER & EMERGENCY SHUT-OFF DETAILNTSGAS GRILLE & FIREBOWL WIRING DETAILNTSGENERATOR MONITORING & START WIRING DIAGRAMNTSDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:42 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE7.1Electrical Details ARC FLASH LABELSNTS10'-0" (Overall Height)4"(WM-3) Planter Wall CapTyp. Planter Wall8 x 8" x 16" Light Weight,CMU W/#4@24" O.C. VertPlace #4x3" Embed @24"O.C. W/Hilti Hit-HY2002'-5"Intermatic Timer For Heater Controls InsideWeatherproof In-Use Cover. Center at 30"From Grade.PlantingPL 1/2" x12"x12" w/(4)12"Dia. x 234"Embed HiltiHas Rods w/ HIT-HY200 Adhesive (Typ.)1-1/2" Pedestal Under ALLEmbed PlatesRe: StructAdjacent PavingPer PlanRe: L2 Series forEmbed Location2'-0"Typical Planter Water ProofingTypical Planter Lightweight SoilStructural WaterproofingDrainage Mat4"6'-6"1"6"8"8"6x6 I-Beam Powdercoated toMatch R&J RailingsWood Veneer Fastedto All Thread BoltsAll Thread RodsWelded to I-Beam9 5 °6"J-Box (typ.) Power Supply to be RunThroughout Courtyard (Typically Belowthe Pedestal Paver System) ViaConduit.Verify J-BOX at Building ConnectionMitered CornerMetal Members Cut to Size &Welded Togethether, Grind allWelds SmoothSupports for HeaterMECHANICAL EQUIPMENT ROOF LIGHTING AND POWER DETAILNTSTYPICAL HEATER POST DETAILNTSTIMECLOCK SWITCH CONTROLLED CONTACTORNTSDate Plotted:HANOVER HYANNIS PH II 55 WILKENS LANE BARNSTABLE, MA 02601 THE HANOVER COMPANY 100% IFC - 03/18/20263/18/2026 5:15:43 PMPROJECT NO:SHEET CONTENTS:NO.DATE:REVISION DESCRIPTION:SCALE:ENGINEEROF RECORD:WOZNY/BARBAR & ASSOCIATES, INC. 1076 WASHINGTON STREET Ã HANOVER, MASSACHUSETTS Ã 02339 781.826.4144 Ã ZZZ.ZEaeQJLQeeUV.FoPREGISTRATIONNUMBER:ISSUED:SHEET NO.CONSULTING ENGINEERS06/10/25 - DESIGN DEVELOPMENT23-3407/22/25 - 50% CD08/19/25 - 70% CD10/01/25 - 90% CD11/21/25 - 100% CONFORMANCE SET03/18/26 - 100% IFCE7.2Electrical Details