HomeMy WebLinkAboutHanover Hyannis II - 100% IFC Structural - 3.18.26Scale Date Drawn By Checked By Project Number 3/18/2026 9:15:06 PMS0.000 Cover Sheet Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Sheet List - VSMsq Sheet Number Sheet Name S0.000 Cover Sheet S0.100 General Notes S0.101 General Notes S0.110 General Notes - Reinforcement S0.111 General Notes - Reinforcement / Embeds S0.130 CMU General Notes / Typical Details S0.131 CMU Typical Details S0.200 3D Views - Bldg#1 - T01 S0.201 3D Views - Bldg#1 - T01 S0.202 3D Views - Bldg#3 - T01 S0.203 3D Views - Bldg#3 - T01 S0.204 3D Views - Bldg T02 S0.205 3D Views - Bldg T02 S0.206 3D Views - Garages S0.207 3D Views - Garages S0.208 3D Views - Clubhouse S0.209 3D Views - Clubhouse S0.300 General Notes - Wood S0.301 General Notes - Wood S0.302 Typical Framing Details - Wood S0.303 Typical Framing Details - Wood S0.304 Stud / Post Schedule - Wood S1.110 Foundation Plan - Bldg #1-T01 - Overall Plan S1.111 Foundation Plan - Bldg #3-T01 - Overall Plan S1.120 Foundation Plan - Bldg #2,#4&#5-T02 - Overall S2.112 Wood Framing Plan - Level 2 - Bldg #1-T01 - Overall Plan S2.113 Wood Framing Plan - Levels 3&4 - Bldg #1-T01 - Overall Plan S2.122 Wood Framing Plan - Level 2 - Bldg #3-T01 - Overall Plan S2.123 Wood Framing Plan - Levels 3&4 - Bldg #3-T01 - Overall Plan S2.132 Wood Framing Plan - Level 2 - Bldg T02 - Overall Plan S2.133 Wood Framing Plan - Levels 3&4 - Bldg T02 - Overall Plan S2.210 Wood Framing Plan - Roof - Bldg #1-T01 - Overall Plan S2.211 Wood Framing Plan - Roof - Bldg #3-T01 - Overall Plan S2.220 Wood Framing Plan - Roof - Bldg T02 - Overall Plan S2.410 Wood Shearwall Plan - Bldg #1-T01 - Overall Plan S2.411 Wood Shearwall Plan - Bldg #3-T01 - Overall Plan S2.420 Wood Shearwall Plan - Bldg T02 - Overall Plan 55 Wilkens Lane Barnstable, MA 02601 Hanover Company VSMsq Project Number: 25070 • ALL STRUCTURAL SHOP DRAWINGS AND RFI'S SUBMITTED ELECTRONICALLY TO VSM2 FOR REVIEW SHALL BE EMAILED TO: ca@vsmsq.com • ALL FIELD REPORTS SUBMITTED ELECTRONICALLY TO VSM2 SHALL BE EMAILED TO: fieldreports@vsmsq.com CONSTRUCTION ADMINISTRATION Sheet List - VSMsq Sheet Number Sheet Name S3.000 Typical Foundation Details S3.001 Typical Foundation Details S3.100 Foundations Sections S3.101 Foundations Sections S4.110 Framing Sections - Wood Floor S4.210 Elevator Framing S4.310 Framing Sections - Wood Roof S4.311 Framing Sections - Wood Roof S4.312 Framing Sections - Wood Roof S4.313 Framing Sections - Wood Roof S4.314 Framing Sections - Wood Roof S5.410 Wood Shear Wall Schedule S5.411 Wood Shear Wall Hold-Downs / Comp Post Schedule - ATR / Rod System S5.412 Wood Shear Wall Hold-Down Details - ATR / Rod System S5.413 Wood Shear Wall Typical Details S5.414 Wood Shear Wall Anchorage ATR / Rod System - Strip and Stem Fdns S5.420 Roof Girder Truss Uplift Details S5.421 Roof Truss Uplift Details SC1-101 Foundation Plan - Clubhouse SC2-102 Framing Plan - Roof - Clubhouse SC2-201 Wood Shearwall Plan - Clubhouse SG1.101 Foundation Plan - Garage A & H SG1.102 Foundation Plan - Garage B & G SG1.103 Foundation Plan - Garage C & F SG1.104 Foundation Plan - Garage D / Maintenance SG1.105 Foundation Plan - Garage E / Dogwash SG2.210 Wood Framing Plan - Roof - Garage A & H SG2.220 Wood Framing Plan - Roof - Garage B & G SG2.230 Wood Framing Plan - Roof - Garage C & F SG2.240 Wood Framing Plan - Roof - Garage D / Maintenance SG2.250 Wood Framing Plan - Roof - Garage E SG2.410 Wood Shearwall Plan - Garage A & H SG2.420 Wood Shearwall Plan - Garage B & G SG2.430 Wood Shearwall Plan - Garage C & F SG2.440 Wood Shearwall Plan - Garage D / Maintenance SG2.450 Wood Shearwall Plan - Garage E / Dogwash No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 GN1.0 GENERAL NOTES 1. THE STRUCTURAL DESIGN PRESENTED IN THESE DOCUMENTS CONFORMS TO THE PROVISIONS OF THE 10th EDITION CMR BUILDING CODE. 2. THE GENERAL CONTRACTOR SHALL REVIEW SHOP DRAWINGS AND NOTE ALL DOCUMENT DISCREPANCIES PRIOR TO SUBMITTAL TO THE DESIGN TEAM FOR APPROVAL, AND SHALL COORDINATE SUBMITTAL RESPONSES BETWEEN SEPARATE SUBCONTRACTORS AS NEEDED. 3. THESE DOCUMENTS REPRESENT STRUCTURAL COMPONENTS IN THEIR FINISHED STATE AT COMPLETION OF THE PROJECT, AND METHODS OF CONSTRUCTION ARE NOT INCLUDED OR IMPLIED HEREIN. THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, AND SAFETY PRECAUTIONS REQUIRED TO COMPLETE THE WORK. 4. CONSTRUCTION VEHICLE LOADS SHALL NOT BE PERMITTED ON ELEVATED STRUCTURAL FRAMING WITHOUT PRIOR WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. 5. MATERIAL TESTING AND SPECIAL INSPECTIONS SHALL BE PERFORMED BY THE OWNER’S THIRD-PARTY TESTING LAB IN ACCORDANCE WITH THESE SPECIFICATIONS AND THE GOVERNING BUILDING CODE AS NOTED ABOVE. UNLESS NOTED OTHERWISE, PERIODIC SITE OBSERVATIONS BY FIELD REPRESENTATIVES OF THE STRUCTURAL ENGINEER DURING CONSTRUCTION ARE CURSORY IN SCOPE AND ARE NOT INTENDED TO BE A CHECK OF THE QUALITY OR QUANTITY OF THE WORK, BUT RATHER ARE SOLELY FOR CONFIRMATION THAT THE WORK OF THE CONTRACTOR IS PROCEEDING IN ACCORDANCE WITH THE GENERAL INTENT OF THE STRUCTURAL CONTRACT DOCUMENTS. THE GENERAL CONTRACTOR SHALL VERIFY COMPLETENESS OF WORK BEFORE SCHEDULING SITE OBSERVATIONS BY THE ENGINEER. 6. DIMENSIONAL CONTROL FOR THE STRUCTURE IS DICTATED BY THE ARCHITECT. GENERAL CONTRACTOR SHALL CONFIRM DIMENSIONS FOR SLAB EDGES, DEPRESSIONS, EXPANSION JOINTS, CURBS, DRAINS, SLEEVES, INSERTS AND ALL OTHER OPENINGS WITH ARCHITECTURAL AND M/E/P DRAWINGS AND SHALL PROVIDE FOR ALL OPENINGS PRIOR TO PLACEMENT OF STRUCTURAL FRAMING. PENETRATIONS AND/OR DEPRESSIONS NOTED BY ARCHITECT OR M/E/P THAT ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO CONSTRUCTION. 7. SUSPENDED LOADS NOT SHOWN IN THE STRUCTURAL DRAWINGS THAT EXCEED 300 POUNDS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. 8. STRUCTURAL FRAMING MEMBERS SHALL BE CENTERED ON GRIDLINES AND EQUALLY SPACED UNLESS NOTED OTHERWISE. 9. PRODUCTS SUBMITTED FOR APPROVAL AS ALTERNATES TO THOSE SPECIFIED IN THE CONTRACT DOCUMENTS SHALL BE ACCOMPANIED BY BOTH A DOCUMENTED COST SAVINGS TO THE OWNER AND A CURRENT INTERNATIONAL CODE COUNCIL (ICC-ES) APPROVAL REPORT TO BE CONSIDERED FOR USE. 10. THE FOLLOWING SPECIFICATIONS OUTLINE THE MATERIAL PROPERTIES AND APPLICATIONS REQUIRED AS A MINIMUM TO CONSTRUCT THE STRUCTURAL COMPONENTS OF THE PROJECT. PRODUCT MANUFACTURER AND LOCAL CODE REQUIREMENTS SHALL CONTROL WHEN IN EXCESS OF THESE MINIMUMS. GN1.2 WIND LOAD CRITERIA ULTIMATE BASIC WIND SPEED (3-SEC GUST), VULT 130 MPH ALLOWABLE STRESS DESIGN WIND SPEED (3-SEC GUST), VASD 101 MPH RISK CATEGORY II WIND EXPOSURE B INTERNAL PRESSURE COEFFICIENT +0.18 COMPONENT & CLADDING PRESSURES SEE PRESSURE ZONE DETAILS GN1.3 SNOW LOAD CRITERIA GROUND SNOW LOAD, Pg 30 PSF SNOW IMPORTANCE FACTOR 1.0 FLAT ROOF SNOW LOAD, Pf 25 PSF SNOW EXPOSURE FACTOR, Ce 1.0 THERMAL FACTOR, Ct 1.0 ADDITIONAL SNOW DRIFT LOADING SEE SNOW DRIFT LOADING DIAGRAM GN1.1 GRAVITY LOAD CRITERIA FLOOR LOADS: SUPERIMPOSED DEAD LOADS: A. CEILING & MECHANICAL 5 PSF B. FIXED PARTITIONS 10 PSF C. TYPICAL GYPCRETE_________________________________________10 PSF D. FLOOR FINISHES____________________________________________ 5 PSF LIVE LOADS: A. UNITS (PRIVATE ROOOM & CORRIDORS SERVING THEM)__40 PSF B. PUBLIC AREAS (PUBLIC ROOMS & CORRIDORS SERVING THEM)100 PSF C. BALCONIES 1.5 x LOAD OF AREA SERVED, 100 PSF MAX D. LOBBY & 1ST FLOOR CORRIDORS 100 PSF / 2,000 LBS CONCENTRATED E. OFFICES 50 PSF F. OFFICE CORRIDORS ABOVE 1ST FLOOR 80 PSF G. MOVEABLE PARTITIONS 15 PSF H. PASSENGER VEHICLE PARKING 40 PSF / 3,000 LBS CONCENTRATED I. LIGHT STORAGE 125 PSF J. TRUCK DOCK 250 PSF / 8,000 LBS CONCENTRATED K. GENERATOR / TRANSFORMER ROOM 125 PSF L. MECHANICAL ROOM 80 PSF ROOF LOADS: SUPERIMPOSED DEAD LOADS: A. CEILING & MECHANICAL ______________________________________5 PSF B. TYPICAL ROOF ASSEMBLY___________________________________15 PSF C. ROOFTOP MECHANICAL EQUIPMENT__________________________AS SPECIFIED BY MECH (30 PSF MIN) D. SOLAR READY AREAS ______________________________________ADDITIONAL 8 PSF LIVE LOADS: A. STANDARD ROOF 20 PSF GN1.4 SEISMIC LOADING CRITERIA SITE CLASSIFICATION D SEISMIC IMPORTANCE FACTOR 1.0 RISK CATEGORY II DESIGN SPECTRAL RESPONSE ACCELERATIONS SS = 0.160 S1 = 0.049 SPECTRAL RESPONSE COEFFICIENTS SDS = 0.171 SD1 = 0.078 SEISMIC DESIGN CATEGORY B SEISMIC FORCE RESISTING SYSTEM LIGHT-FRAME WALLS WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE SEISMIC RESPONSE COEFFICIENT, CS 0.0263 RESPONSE MODIFICATION FACTOR, R 6.5 DESIGN BASE SHEAR X –DIRECTION = Cs X BUILDING WEIGHT Y –DIRECTION = Cs X BUILDING WEIGHT DEFLECTION AMPLIFICATION FACTOR, Cd 4 ANALYSIS PROCEDURE (ELFP or MRSA)ELFP GN1.5 DEFERRED SUBMITTALS 1. DESIGN AND DETAILING OF THE BUILDING COMPONENTS LISTED BELOW ARE DELEGATED TO THE GENERAL CONTRACTOR’S SPECIALTY ENGINEER AND SHALL BE CONSIDERED DEFERRED SUBMITTALS FOR PERMITTING PURPOSES IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 107.3.4.1. 2. DESIGN DOCUMENTS SHALL BE SIGNED AND SEALED BY AN ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT AND SUBMITTED TO THE ARCHITECT AND ENGINEER FOR REVIEW AND COORDINATION PRIOR TO SUBMISSION TO THE BUILDING OFFICIAL FOR THEIR REVIEW AND APPROVAL. DESIGN DOCUMENTS SHALL INCLUDE DETAILED DRAWINGS AS WELL AS ENGINEERING CALCULATIONS. 3. DEFERRED SUBMITTAL ITEMS INCLUDE BUT MAY NOT BE LIMITED TO THE FOLLOWING: A. ALL SITE STRUCTURES (RETAINING WALLS, FENCING, TRELLISES, LANDSCAPE AND/OR CIVIL STRUCTURES, ETC.) B. SPECIALTY PERFORMANCE SPECIFIED FOUNDATION SYSTEMS (RAMMED AGGREGATE PIERS, PRECAST PILES, MICROPILES, ETC.) C. PRECAST CONCRETE, BOTH STRUCTURAL FRAMING MEMBERS AND ARCHITECTURAL CLADDING D. STEEL STAIRS E. PRECAST STAIRS F. HANDRAILS G. CABLE BARRIERS H. STRUCTURAL STEEL CONNECTIONS I. CURTAIN WALL AND WINDOW WALL SYSTEMS J. COLD-FORMED METAL STUD (CFMS) FRAMING (NON-LOAD BEARING WALLS, SOFFITS, ARCHITECTURAL SECTIONS, ETC.) K. COLD-FORMED STEEL TRUSS FRAMING L. PRE-ENGINEERED WOOD FLOOR AND ROOF TRUSSES M. ALL OTHER SYSTEMS NOT SPECIFICALLY SHOWN IN THE STRUCTURAL DOCUMENTS GN2.0 ABBREVIATIONS (GENERAL): @ AT & AND = / EQ EQUAL / EQUALS ≠ NOT EQUAL ± PLUS OR MINUS ° / DEG DEGREES ⌀/ DIA DIAMETER AB ANCHOR BOLT ADD'L ADDITIONAL ALT ALTERNATE ARCH ARCHITECT ASD ALLOWABLE STRESS DESIGN BLDG BUILDING BM BEAM B.O. BOTTOM OF BOF BOTTOM OF FOUNDATION / FOOTING BOW BOTTOM OF WALL BRG BEARING CANT CANTILEVER ℄/ C.L. CENTERLINE CJ CONSTRUCTION JOINT CLR CLEAR COL COLUMN CONFIG CONFIGURE / CONFIGURATION CONSTR CONSTRUCTION CONT CONTINUOUS COORD COORDINATE CTRS CENTERS DIM DIMENSION DET DETAIL DWG DRAWING EA EACH EE EACH END EJ EXPANSION JOINT EL / ELEV ELEVATION EF EACH FACE ENGR ENGINEER EPXY EPOXY ES EACH SIDE EOR ENGINEER OF RECORD EQ EQUAL EW EACH WAY EXP EXPANSION EXT EXTERIOR F.D. FLOOR DRAIN FIN FINISH FLR FLOOR FND FOUNDATION FT FOOT / FEET F.S. FAR SIDE GC GENERAL CONTRACTOR GR GRADE HORIZ HORIZONTAL HP HIGH POINT HT HEIGHT ID INSIDE DIAMETER IN INCH INFO INFORMATION INT INTERIOR JT JOINT LGTH LENGTH LNG LONG LP LOW POINT MANUF MANUFACTURE MAX MAXIMUM MDF MEDIUM-DENSITY FIBERBOARD MDO MEDIUM-DENSITY OVERLAY MECH MECHANICAL MISC MISCELLANEOUS MIN. MINIMUM NIC NOT IN CONTRACT N.S. NEAR SIDE # / NO. NUMBER O.A. OVER ALL O.C. ON CENTER O.D. OUTSIDE DIAMETER O.H. OPPOSITE HAND OPNG OPENING OPP OPPOSITE PAR PARALLEL PERP PERPENDICULAR P.L. PROPERTY LINE PLF POUNDS PER LINEAR FOOT PRELIM PRELIMINARY PROP PROPERTY QT /QTY QUANTITY R / RAD. RADIUS RE / REF REFERENCE REQ'D REQUIRED REM REMAINDER REINF REINFORCEMENT RTU ROOF TOP UNIT S.B. SET BACK SCHED SCHEDULE (D) SEOR STRUCTURAL ENGINEER OF RECORD SIM SIMILAR SOG SLAB ON GRADE SPEC SPECIFICATION SQ. SQUARE STD STANDARD STRUCT STRUCTURE / STRUCTURAL SYM SYMMETRIC / SYMMETRICAL T.O. TOP OF TOF TOP OF FOUNDATION / FOOTING TOW TOP OF WALL UNO UNLESS NOTED OTHERWISE VERT VERTICAL W/ WITH W/O WITH OUT GN2.1 ABBREVIATIONS (STRUCTURAL): db BAR DIAMETER f'c 28 DAY CONCRETE STRENGTH f'm 28 DAY MASONRY STRENGTH Fe EFFECTIVE FORCE Fy YIELD STRENGTH K KIPS (1,000 LBS) KLF KIPS PER LINEAR FOOT KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH ℓd / Ld DEVELOPMENT LENGTH LB / LBS POUND / POUNDS GN2.2 ABBREVIATIONS (STRUCTURALLY SOCIETIES / INSTITUTES): ACI AMERICAN CONCRETE INSTITUTE AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY BIA BRICK INSTITUTE of AMERICA CRSI CONCRETE REINFORCING STEEL INSTITUTE IBC INTERVENTIONAL BUILDING CODE ICC INTERNATIONAL CODE COUNCIL ICBO INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS PCI PRECAST / PRESTRESSED CONCRETE INSTITUTE SJI THE STEEL JOIST INSTITUTE LRFD LOAD AND RESISTANCE FACTOR DESIGN P AXIAL LOAD PCF POUNDS PER CUBIC FOOT PCY POUNDS PER CUBIC YARD PSI POUNDS PER SQUARE INCH PSF POUNDS PER SQUARE FOOT T TORSION GN2.3 ABBREVIATIONS (CONCRETE / MASONRY): ACIP AUGERED CAST-IN-PLACE PILES BOF BOTTOM OF FOOTING / FOUNDATION BOW BOTTOM OF WALL CIP CAST IN PLACE CONC CONCRETE COV COVER CMU CONCRETE MASONRY UNIT db BAR DIAMETER DBA DEFORMED BAR ANCHOR DWL DOWEL EPXY EPOXY FDN FOUNDATION HSA HEADED STUD ANCHOR ℓd / Ld DEVELOPMENT LENGTH L.W .LIGHT WEIGHT LWC LIGHT WEIGHT CONCRETE N.W.NORMAL WEIGHT NWC NORMAL WEIGHT CONCRETE PT POST TENSION REINF REINFORCEMENT RS ROCK SOCKET SOG SLAB ON GRADE TOC TOP OF CONCRETE TOF TOP OF FOOTING / FOUNDATION TO PIL TOP OF PILASTER TOW TOP OF WALL WP WORKING POINT WWF WELDED WIRE FABRIC WWM WELDED WIRE MESH WWR WELDED WIRE REINFORCEMENT GN2.4 ABBREVIATIONS (STEEL / LIGHT GAUGE FRAMING): BB BACK TO BACK BOS BOTTOM OF STEEL COMP COMPOSITE DCW DEMAND CRITICAL WELD FP FULL PENETRATION GALV GALVANIZED HSA HEADED STUD ANCHOR HSS HOLLOW STRUCTURAL SECTION KB KNEE BRACE L ANGLE LLBB LONG LEG BACK TO BACK LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LG LIGHT GAUGE LSH LONG SIDE HORIZONTAL LSV LONG SIDE VERTICAL MC MOMENT CONNECTION MTL METAL PAF POWER ACTUATED FASTENER PJP PARTIAL JOINT PENETRATION PL PLATE SS STAINLESS STEEL STIF STIFFENER STL STEEL TOS TOP OF STEEL TS TUBE SECTION WF WIDE FLANGE WP WORKING POINT WT WIDE FLANGE TEE XS EXTRA STRONG XXS DOUBLE EXTRA STRONG GN2.5 ABBREVIATIONS (WOOD FRAMING): B.N.BOUNDARY NAILING CLT CROSS LAMINATED TIMBER D.B.DROP BEAM DFL DOUGLAS FIR LARCH E.N.EDGE NAILING F.B.FLUSH BEAM FRT FIRE RETARDANT TREATED GL GLUED LAMINATED TIMBER (GLU-LAM) GT GIRDER TRUSS GWB GYPSUM WALL BOARD GYP GYPSUM HDR HEADER HNGR HANGER LBW LOAD BEARING WALL LSL LAMINATED STRAND LUMBER LVL LAMINATED VENEER LUMBER NLBW NON-LOAD BEARING WALL OSB ORIENTED STRAND BOARD PLY PLYWOOD PSL PARALLEL STRAND LUMBER PT PRESSURE TREATED SS SELECT STRUCTURAL SW SHEAR WALL SWL SHEAR WALL LENGTH SYP SOUTHER YELLOW PINE WSP WOOD STRUCTURAL PANEL GN3.0 PLAN SYMBOLOGY: = CAST IN PLACE CONCRETE (CIP CONC) COLUMNS / WALLS = CMU WALL = CMU WALL OVER CIP CONCRETE VEHICLE BARRIER = LOAD BEARING METAL STUD FRAMED WALL = LOAD BEARING WOOD FRAMED STUD WALL = EXTERIOR NON-LOAD BEARING WOOD FRAMED STUD WALL = EXTERIOR 2 HOUR RATED LOAD BEARING WOOD FRAMED STUD WALL = WOOD SHEAR WALL = PRECAST COLUMN / WALL = TEMPORARY SHORING STEEL GRATING WOOD STRUCTUREFORMED CONCRETE EXISTING POUR STRIP / STRESSING BLOCKOUT TENANT SLAB GN3.1 DETAIL / ELEVATION SYMBOLOGY: = CAST IN PLACE CONCRETE CUT = CAST IN PLACE CONCRETE BEYOND = POUR STRIP / STRESSING BLOCKOUT = CONCRETE TOPPING = GYPCRETE = PRECAST CONCRETE CUT = PRECAST CONCRETE BEYOND = GROUT = CMU WALL = MASONRY VENEER = STEEL = ALUMINUM = EARTH = UNDISTURBED EARTH = SELECT FILL / MOISTURE CONDITIONED SOIL = GRANULAR CUSHION / FILL = GRAVEL = ROCK = STRUCTURAL STYROFOAM = CAST STONE = TEMPORARY SHORING = TENANT SLAB = EXISTING GN3.3 CIP CONCRETE PLAN SYMBOLS: = POST TENSION TENDON = TOP REBAR (TOP STEEL) = TOP REBAR WITH STANDARD 90° HOOK = MID DEPTH REBAR (BOTTOM STEEL) = MID DEPTH REBAR WITH STANDARD 90° HOOK = BOTTOM REBAR (BOTTOM STEEL) = BOTTOM REBAR WITH STANDARD 90° HOOK = TOP & BOTTOM REBAR (TOP & BOTTOM STEEL) = TOP & BOTTOM REBAR WITH STANDARD 90° HOOK = DOWEL WITH FORMSAVER (FS) (INDICATED AS TOP REBAR) = REBAR WITH STANDARD 180° HOOK (INDICATED AS TOP REBAR) DEAD END STRESSING / LIVE END C-1 SR-1 COLUMN ID SHEAR STUD REINFORCEMENT ID IF INDICATED LINK BEAM ID IF INDICATED SW-1.1 LB-A.1 SHEARWALL ID CIP CONCRETE COLUMN CIP SHEARWALL (24 x 24) COLUMN SIZE GN3.2 GENERAL SYMBOLS: = SLAB SPAN (TWO WAY) = SLAB SPAN (TWO WAY) = TRUE NORTH ARROW = PROJECT NORTH ARROW = LATERAL CONNECTION = GRAVITY AND LATERAL CONNECTION = BREAK LINE = ROUND BREAK LINE THK. THK. SLAB TYPE / THICKNESS IF SPECIFIED SLAB TYPE / THICKNESS IF SPECIFIED GN3.4 STEEL PLAN SYMBOLOGY: = STEEL COLUMNS 2' - 7" WIDE FLANGE COLUMN PIPE / ROUND HSS COLUMN HSS COLUMN STEEL BRACE STEEL BEAMS BRACE MEMBER ABOVE BRACE MEMBER BELOW UPWARD PRE-COMPOSITE BEAM CAMBER W18X35 C=3/4" BEAM SIZE QUANTITY OF 3/4"⌀ COMPOSITE SHEAR STUDS LOCATED AS SHOWN (ON NON-UNIFORM COMPOSITE BEAMS WHERE SPECIFIED) W18X35 (12) C=3/4" BEAM SIZE QUANTITY OF 3/4"⌀ COMPOSITE SHEAR STUDS EVENLY DISTRIBUTED(ON UNIFORM COMPOSITE BEAMS WHERE SPECIFIED) (6)(6)(4)(5)(4)HSS6X6X1/4COLUMN SIZE INDICATED AT HIGHEST LEVEL COLUMN OCCURS (WHEN GRAPHICAL COLUMN SCHEDULE IS NOT PROVIDE IN DOCUMENTS) 64K65K 64K65K ASD LEVEL BEAM REACTIONS UPWARD PRE-COMPOSITE BEAM CAMBER ASD LEVEL BEAM REACTIONS COLUMNS ARE CENTERED ON GRIDLINES (U.N.O.) = FULL PENETRATION MOMENT CONNECTION = FULL PENETRATION CANTILEVERED MOMENT CONNECTION AT COLUMN = FULL PENETRATION CANTILEVERED MOMENT CONNECTION THROUGH BEAM = STUB COLUMN = BEAM SPLICE GN3.5 FOUNDATION SYMBOLS: PC-10 PIER / PILE CAP ID -SEE SCHEDULE / ENLARGED PLANS FOR SIZE AND REINFORCEMENT PILE / PIER CAP TOF = +X'-X" TOF = TOP OF PIER / PILE CAP BOF = BOTTOM OF PIER / PILE CAP PIER / PILE ID, SHAFT DIAMETER -SEE PIER SCHEDULE REINFORCEMENT STRAIGHT SHAFT PIER / PILE TOF = TOP OF PIER / PILE P-60 TOF = +X'-X" (-2'-8") PIER / PILE EMBEDMENT INTO BEARING STRATA DESIGNATED BY GEOTECHNICAL REPORT SHAFT DIAMETER / BELL DIAMETER -SEE BELLED PIER SCHEDULE REINFORCEMENT BELL BOTTOM PIER TOF = TOP OF PIER / PILE P24/48 TOF = +X'-X" WF-36 STRIP / WALL FOOTING STRIP / WALL FOOTING ID -SEE WALL FOOTING SCHEDULE SIZE AND REINFORCEMENT F-10 SPREAD FOOTING ID - SEE SPREAD FOOTING SCHEDULE FOR SIZE AND REINFORCEMENT SPREAD FOOTING TOF = +X'-X" TOF = TOP OF FOOTING BOF = BOTTOM OF FOOTING FN1.0 SPREAD FOOTING FOUNDATIONS 1. SPREAD FOOTING FOUNDATION DESIGN IS BASED ON GEOTECHNICAL ENGINEERING REPORT NO.5667.00 PREPARED BY SANBORN, HEAD, & ASSOCIATES, INC. DATED SEPTEMBER 5, 2023, AND ALL ISSUED ADDENDUMS USING THE FOLLOWING RECOMMENDED DESIGN CRITERIA: ALLOWABLE NET BEARING 6,000 psf 2. CONTRACTOR TO REVIEW GEOTECHNICAL REPORT AND FOLLOW ALL RECOMMENDATIONS NOTED THEREIN. 3. FOOTING EXCAVATIONS SHALL BE INSPECTED BY THE GEOTECHNICAL ENGINEER OR THE OWNER’S SPECIAL INSPECTOR PRIOR TO REINFORCEMENT AND CONCRETE PLACEMENT TO ENSURE BEARING SURFACES ARE CONSISTENT WITH DESIGN RECOMMENDATIONS PROVIDED IN THE GEOTECHNICAL REPORT. 4. FOOTING EXCAVATIONS SHALL BE FREE OF WATER PRIOR TO CONCRETE PLACEMENT. IF QUESTIONABLE SOILS ARE ENCOUNTERED, THE GEOTECHNICAL ENGINEER AND STRUCTURAL ENGINEER SHOULD BE NOTIFIED IMMEDIATELY. 5. FOOTING EXCAVATION SHALL BE NEAT UNLESS SPECIFICALLY NOTED IN THE GEOTECHNICAL REPORT AND THE CONTRACTOR HAS PLANNED FOR FORMED FOOTINGS. 6. FOOTINGS SHALL BE PLACED THE SAME DAY THAT EXCAVATION OCCURS. EXCAVATIONS SHALL NOT BE LEFT OPEN OVERNIGHT WITHOUT THE WRITTEN CONSENT OF THE GEOTECHNICAL ENGINEER. 7. GEOTECHNICAL ENGINEER TO REVIEW STRUCTURAL DRAWINGS PRIOR TO THE START OF CONSTRUCTION TO CONFIRM RECOMMENDATIONS IN THEIR REPORT HAVE BEEN PROPERLY INTERPRETED. 8. PROVIDE RADON BARRIER AS REQUIRED BY SOIL ANALYSIS & GEOTECHNICAL REQUIREMENTS. GRANULAR CUSHION VAPOR RETARDER PROVIDE PROPER DRAINAGE IN ACCORDANCE W/ GEOTECHNICAL REPORT FOUNDATIONS PER STRUCTURAL PLANS EXTERIOR EDGE OF SLAB SITE PREPARATION SCHEMATIC UNDISTURBED NATURAL GRADE NOTE: 1. GRANULAR CUSHION TO BE OMITTED ON SLAB ON GRADE CONDITIONS WITH VEHICULAR TRAFFIC. 2. RE: RADON SYSTEM PLAN AND DETAILS FOR ADDITIONAL INFORMATION REGARDING SUBGRADE BELOW BUILDING SLABS. 5'-0" MINIMUM IN ACCORDANCE W/ GEOTECHNICAL REPORTSELECT FILL OR SUBGRADE TREATMENT USINGMOISTURE CONDITIONED SOIL TO ACHIEVE 1" PVREXTERIOR FOUNDATION; SEE FOUNDATION PLANS AND DETAILS MIN. 4'-0" R-10 PERIMETER VERT PER ENERGY REQUIREMENTS MAX.9"Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:15:07 PMS0.100 General Notes Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 GN3.0 COMPONENT AND CLADDING FOR WIND PRESSURE DIAGRAMS: 1. PRESSURES SHOWN ARE BASED ON SERVICE LEVEL (3-SEC) WIND VELOCITY, (VASD). FOR ULTIMATE LOADS, DIVIDE PRESSURES GIVEN BY 0.6. 2. PARAPET DESIGN PRESSURES CONSIST OF APPLYING THE APPLICABLE POSITIVE PRESSURE TO ONE SIDE OF THE PARAPET AND NEGATIVE PRESSURE TO THE OPPOSITE SIDE. 3. REFER TO BUILDING CODE FOR IMPACT RESISTANT GLAZING REQUIREMENTS IN HURRICANE PRONE REGIONS. BUILDING WITH GABLE ROOFaa a a5 5 5 5 4 4 1 2 3 3 2 2 2 3 3 BUILDING WITH HIP ROOFaa 5 5 4 3 2 1 1 2 TYP AT CORNERS 4 a (TYP)aa (TYP)aa (T Y P )OVERHANG OVERHANG O V E R H A N G +14.5 PSF -26.6 PSF DESIGN WIND PRESSURE -GABLE / HIP ROOFS (SLOPES GREATER THAN 27° / LESS THAN 45°) (LOADS INDICATED ARE SERVICE LOADS)TRIB AREA FT2 ZONE 10 1 ZONE 2 ZONE 3 +14.5 PSF -29.2 PSF +14.5 PSF -35.9 PSF +10.7 PSF -17.2 PSF50 +10.7 PSF -22.0 PSF +10.7 PSF -26.4 PSF +9.1 PSF -13.1 PSF100 +9.1 PSF -18.9 PSF +9.1 PSF -22.3 PSF 2 2 22 a (TYP)a (TYP) 5 5 O V E R H A N G +14.5 PSF -40.0 PSF +14.5 PSF -46.6 PSF +10.7 PSF -32.8 PSF +10.7 PSF -37.1 PSF +9.1 PSF -29.7 PSF +9.1 PSF -33.0 PSF OVER HANG 2 3OVER HANG +10.4 PSF -18.6 PSF DESIGN WIND PRESSURE -HIP ROOFS (SLOPES GREATER THAN 20° / LESS THAN 27°) (LOADS INDICATED ARE SERVICE LOADS) TRIB AREA FT2 ZONE 10 1 ZONE 2 ZONE 3 +10.4 PSF -25.7 PSF +10.4 PSF -25.7 PSF +7.1 PSF -13.7 PSF50 +7.1 PSF -29.4 PSF +7.1 PSF -29.4 PSF +5.7 PSF -11.5 PSF100 +5.7 PSF -16.6 PSF +5.7 PSF -16.6 PSF +10.4 PSF -31.0 PSF +10.4 PSF -36.6 PSF +7.1 PSF -28.1 PSF +7.1 PSF -27.6 PSF +5.7 PSF -26.9 PSF +5.7 PSF -23.7 PSF OVER HANG 2 3OVER HANG +14.6 PSF -22.8 PSF DESIGN WIND PRESSURE WALLS (LOADS INDICATED ARE SERVICE LOADS) TRIB AREA FT2 ZONE 10 4 ZONE 5 +14.6 PSF -28.1 PSF +14.1 PSF -22.3 PSF50 +14.1 PSF -27.2 PSF +13.6 PSF -21.8 PSF100 +13.6 PSF -26.1 PSF 8'-0" ZONE LENGTHS LENGTH a ZONE 2 a (T Y P )+15.7 PSF -28.1 PSF DESIGN WIND PRESSURE -HIP ROOFS (LOADS INDICATED ARE SERVICE LOADS)TRIB AREA FT2 ZONE 10 1 ZONE 2 ZONE 3 +15.7 PSF -38.8 PSF +15.7 PSF -38.8 PSF +10.7 PSF -20.6 PSF50 +10.7 PSF -29.2 PSF +10.7 PSF -29.2 PSF +8.5 PSF -17.4 PSF100 +8.5 PSF -25.1 PSF +8.5 PSF -25.1 PSF +15.7 PSF -35.3 PSF +15.7 PSF -46.7 PSF +10.7 PSF -27.6 PSF +10.7 PSF -42.4 PSF +8.5 PSF -24.3 PSF +8.5 PSF -40.6 PSF OVER HANG 1 2OVER HANG +15.7 PSF -55.3 PSF +10.7 PSF -41.6 PSF +8.5 PSF 35.8 PSF 3OVER HANG MISCELLANEOUS BUILDINGS RESIDENTIAL APARTMENT BUILDINGS ITEM FOUNDATIONS: GRADING, EXCAVATION, AND FILL MASONRY: PROTECTION OF MASONRY WHEN TEMPERATURES EXCEED 90° AND BELOW 40° TESTING DRILLED PIERS / PILES REQUIRED CONCRETE: VERIFY USE OF PROPER MIX DESIGN BATCH PLANT INSPECTION REBAR PLACEMENT REBAR WELDING POST -TENSION REINFOCEMENT PLACEMENT POST -TENSION STRESSING AND ENCAPSULATION SYSTEM GREASE CAP INSTALLATION FOOTINGS AND PIER / PILE CAPS ANCHOR BOLTS AND EMBED PLATES EPOXY POST-INSTALLED ANCHORS (MECHANICAL / ADHESIVE) PRE-CAST CONCRETE ERECTION CONCRETE PLACEMENT SHOT CRETE PLACEMENT VERIFICATION OF PROPORTIONS OF SITE PREPARED MORTAR LIGHT GAUGE FRAMING: VERIFICATION OF CLEAN GROUT SPACE PRIOR TO REINF AND GROUT PLACEMENT SIZE, GRADE, AND TYPE OF REBAR ANCHORS SIZE, TYPE, AND LOCATION REBAR WELDING REBAR PLACEMENT GROUT PLACEMENT COMPLIANCE WITH REQ'D INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND THE APPOVED SUBMITTALS VERIFIED LOCATION OF REBAR AND CONNECTORS VERIFICATION VERIFICATION OF MORTOR JOINTS SIZE AND LOCATION OF STRUCTURAL ELEMENTS STRUCTURAL STEEL: SHOP AND FIELD WELDING STUD PLACEMENT SHOP WELDING -FILLET WELDS SHOP WELDING -PARTIAL OR FULL PENETRATION WELDS STRUCTURAL WOOD FRAMING: NAILING AND BOLTING UPLIFT ANCHORS AND HOLD-DOWNS SHEARWALL, DIAPHRAGMS, DRAG STRUTS, AND BRACES FIELD WELDING -FILLET WELDS FIELD WELDING -PARTIAL OR FULL PENETRATION WELDS BOLTED CONNECTIONS BY GEOTECHNICAL EOR CONTINUOUS CONTINUOUS PERIODIC FINAL PLACEMENT FINAL PLACEMENT FINAL PLACEMENT CONTINUOUS CONTINUOUS CONTINUOUS PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC PERIODIC CONTINUOUS PERIODIC PERIODIC CONTINUOUS PERIODIC PERIODIC PERIODIC PERIODIC GN5.0 SPECIAL INSPECTIONS: 1. ALL ITEMS NOTED IN TABLE BELOW AS REQUIRED SHALL BE INSPECTED IN ACCORDANCE WITH IBC SECTION 1704 BY A CERTIFIED SPECIAL INSPECTOR FROM AN ESTABLISHED TESTING AGENCY. 2. ALL ITEMS TO BE TESTED AT THE INTERVALS INDICATED IN THE TABLE BELOW UNDER TESTING. 3. THE TESTING AGENCY SHALL PROVIDE COPIES OF ALL STRUCTURAL TESTING AND INSPECTION REPORTS TO THE EOR, ARCHITECT, OWNER, BUILDING DEPARTMENT (IF REQUIRED), AND CONTRACTOR. 4. ANY AND ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OFR THE CONTRACTOR FOR CORRECTION. ALL ITEMS LEFT UNCORRECTED SHALL BE BROUGHT TO THE ATTENTION OF THE EOR, ARCHITECT AND BUILDING DEPARTMENT (IF REQUIRED) 5. UPON COMPLETION OF THE PROJECT, THE TESTING AGENCY SHALL PROVIDE EOR, ARCHITECT, AND OWNER A STATEMENT SIGNED AND DATED BY A LICENSED PROFESSIONAL ENGINEER, THAT TO THE BEST OF THEIR KNOWLEDGE, ALL REQUIRED INSPECTIONS WHERE MADE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 6. FOR MATERIAL SAMPLING / TESTING REQUIREMENTS, REFER TO GN5.1 MATERIAL SAMPLING TABLE BELOW. CONTINUOUS GN5.1 MATERIAL SAMPLING: 1. ALL ITEMS NOTED IN TABLE BELOW AS REQUIRED SHALL BE SAMPLED AND TESTED BY A CERTIFIED INSPECTOR FROM AN ESTABLISHED TESTING AGENCY IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, GENERAL NOTES OR PREVAILING BUILDING CODE (WICH EVER IS MORE STRINGENT). 2. ALL MATERIAL SAMPLING AND TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM REQUIREMENTS 3. FOR ADDITIONAL INFORMATION ON MATERIAL SAMPLING AND TESTING, REFERS TO PROJECT SPECIFICATIONS AND GENERAL NOTES. 4. THE TESTING AGENCY SHALL SEND COPIES OF ALL STRUCTURAL TESTING REPORTS DIRECTLY TO THE STRUCTURAL EOR, ARCHITECT, OWNER, BUILDING DEPARTMENT (IF REQUIRED), AND CONTRACTOR. 5. ANY MATERIALS THAT FAIL TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE STRUCTURAL EOR. ITEM MASONRY: PREPERATION OF ANY REQD GROUP SPECIMENS, MORTAR SPECIMENS, AND/OR PRISMS TESTINGREQUIRED CONCRETE: CYLINDERS DESIGN MIX REBAR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND CURING TECHNIQUES VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO STRESSING OF POST - TENSION TENDONS IN POSITIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS STRUCTURAL STEEL: ULTRASONIC TESTING BEND TEST ON WELDED STUDS AS REQD BY SPECIFICATIONS MILL CERTIFICATES TWO 5'-0" MIN. SAMPLES PER REEL. (ONE FROM EACH END CONTINUOUS PERIODIC CONTINUOUS PERIODIC - - CONTINUOUS SAMPLING FRESH CONCRETE AND PERFORMING SLUMP TESTING, AIR CONTENT TESTING, DETERMING THE TEMERATURE AT THE FRESH CONCRETE AT THE TIME OF MACKING SPECIMENS FOR STRENGTH TESTS. POST -TENSION TENDONS MONITOR TEMPERATURE DURING CURINGLARGE CONCRETE MAT TEMPERATURE MONITORING DURING INITIAL CURING POST-INSTALLED ANCHORS (MECHANICAL / ADHESIVE)COORD W/STRUCTURAL EOR FOR FREQUENCY OF TESTING UTS SANSBORN HEAD TESTING ENTITY UTS UTS UTS UTS UTS UTS VSM N/A N/A N/A N/A UTS UTS UTS TESTING ENTITY UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS UTS N/A N/A N/A N/A N/A N/A VSM VSM VSM UTS UTS UTS UTS UTS N/A UTS UTS UTS UTS ST1.0 STRUCTURAL STEEL NOTES: 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AND THE AISC 303 “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”, LATEST APPROVED EDITIONS REFERENCED IN GOVERNING BUILDING CODE. 2. THE STRUCTURAL DRAWINGS REPRESENT TYPICAL FINAL CONDITIONS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED ERECTION AIDS, TEMPORARY BRACING, AND ENSURING THAT FABRICATION AND ERECTION OF STRUCTURAL STEEL COMPLIES WITH APPLICABLE OSHA REQUIREMENTS. 3. GENERAL CONTRACTOR SHALL SUBMIT DETAILED SHOP AND INSTALLATION DRAWINGS SHOWING SHOP AND ERECTION DETAILS INCLUDING MEMBER SIZES, GRADES OF MATERIALS, DETAILS OF FABRICATION AND ERECTION, AND MEMBER CONNECTIONS. PROCUREMENT AND/OR FABRICATION OF MATERIAL PRIOR TO SHOP DRAWINGS APPROVAL SHALL BE AT THE CONTRACTOR’S RISK. 4. MEMBER CONNECTIONS SHALL BE DELEGATED AS NOTED IN “STRUCTURAL STEEL CONNECTION NOTES”. 5. MEMBER CONNECTIONS SHALL BE FULLY COMPLETED AND INSPECTED PRIOR TO CASTING CONCRETE SLAB. 6. MEMBER SPLICES, PENETRATIONS, AND OTHER MODIFICATIONS OF STRUCTURAL STEEL MEMBERS IS PROHIBITED WITHOUT SPECIFIC APPROVAL FROM STRUCTURAL ENGINEER FOR EACH LOCATION AND CONNECTION TYPE UNLESS NOTED OTHERWISE IN THE STRUCTURAL DRAWINGS. 7. VERIFY THE SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS FOR MECHANICAL AND ELECTRICAL REQUIREMENTS AND COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTOR PRIOR TO FABRICATION OF MATERIALS. 8. STRUCTURAL STEEL MATERIALS SHALL BE NEW STEEL AND CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS U.N.O.: • WIDE FLANGES ASTM A992 Gr. 50 • OTHER ROLLED SHAPES, PLATES, BARS ASTM A36 • PIPE ASTM A53 Gr. B • HOLLOW STRUCTURAL SECTIONS -HSS ASTM A500 Gr. C • BOLTS ASTM F3125 Grade A325 or A490 • ANCHOR BOLTS ASTM F1554 Grade 36 • HIGH STRENGTH ANCHOR BOLTS ASTM F1554 Grade 55 (S1) or 105 • WELDING ELECTRODES E70XX • STUD SHEAR CONNECTORS ASTM A108 & AWS D1.1 TYPE B (NELSON FLUX FILLED OR APPROVED EQUIVALENT) • DEFORMED BAR ANCHORS ASTM A1064 Grade 70 (NELSON D2L OR APPROVED EQUIVALENT) 9. STEEL THAT IS NOT EXPOSED TO VIEW SHALL BE CLEANED PER SSPC-SP2 AND PAINTED WITH ONE SHOP COAT OF RED OXIDE PRIMER, MINIMUM OF 1.5 MILS (DRY FILM THICKNESS). DO NOT PAINT STRUCTURAL STEEL AND ANCHOR RODS THAT ARE TO BE EMBEDDED IN CONCRETE OR TO RECEIVE FIREPROOFING. STEEL AT OR BELOW FINISHED GRADE OR BELOW FLOOR SLAB SHALL RECEIVE 2 COATS OF BITUMINOUS PAINT OR 3”MINIMUM CONCRETE COVER. STRUCTURAL STEEL SHALL BE TOUCHED UP AFTER ERECTION WITH PRIMER/PAINT TO MATCH SHOP PREP. 10. EXPOSED TO VIEW STEEL FINISH AND QUALITY STANDARD NOTED IN THESE DOCUMENTS ARE DEFINED BASED ON AISC 303-16 INCLUDING AESS1, AESS2, AESS3 AND AESS4. REFER TO THE DRAWINGS FOR SPECIFIC MEMBERS REQUIRED TO MEET ONE OF THESE STANDARDS AND REFER TO AISC 303-16 FOR ADDITIONAL INFORMATION. IF ARCHITECTURALLY EXPOSED STRUCTURAL STEEL STANDARDS NOTED IN THESE DOCUMENTS DIFFERS FROM THOSE NOTED IN THE ARCHITECTURAL DOCUMENTS, THE MORE STRINGENT STANDARD SHALL BE FOLLOWED. 11. THE CONTRACTOR SHALL REVIEW SHOP AND FIELD WELD REQUIREMENTS FOR COMPATIBILITY WITH THE CONSTRUCTION SEQUENCE. PROPOSED REVISIONS FROM SHOP TO FIELD WELDS OR FROM FIELD TO SHOP WELDS SHALL BE IDENTIFIED BY THE CONTRACTOR ON THE SHOP DRAWINGS. 12. ANCHOR RODS TO BE EMBEDDED IN CONCRETE SHALL BE SET USING A STEEL TEMPLATE THAT ENSURES BOLTS MAINTAIN PROPER POSITIONING DURING CONCRETE PLACEMENT. ANCHOR RODS THAT ARE OMITTED OR MISPLACED MAY NOT BE SUITABLE FOR POST INSTALLED SUBSTITUTES AND MAY REQUIRE DEMOLITION AND REPLACEMENT OF CONCRETE SECTION. 13. GROUT FOR LEVELING OF BASE PLATES SHALL BE NON-SHRINK, NON METALLIC, AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 8,000 PSI AT 28 DAYS AND CONFORM TO ASTM C1107 U.N.O.. 14. MECHANICAL UNITS (SUCH AS A/C UNITS, HEATER UNITS, ETC.) ARE NOT TO BE HUNG FROM STRUCTURE WITHOUT THE ENGINEER'S APPROVAL, UNLESS SHOWN ON THE STRUCTURAL DRAWINGS. 15. EDGE ANGLES SUPPORTING FLOOR AND ROOF DECK SHALL BE SPLICED ONLY OVER SUPPORTS. 16. FABRICATE STEEL BEAMS WITH CAMBER UP U.N.O.. 17. GENERAL CONTRACTOR SHALL NOTIFY STRUCTURAL ENGINEER IN WRITING OF FABRICATION OR ERECTION ERRORS AND RECEIVE WRITTEN APPROVAL BEFORE TAKING CORRECTIVE ACTION INVOLVING MODIFICATIONS TO STRUCTURAL MEMBERS OR FRAMING. 18. GENERAL CONTRACTOR SHALL PROVIDE STRCUTURAL STEEL AS SHOWN IN THE FULL SET OF PROJECT CONTRACT DOCUMENTS (INCLUDING ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC...). DISCREPANCIES BETWEEN THE STRUCTURAL DRAWINGS AND OTHER CONSULTANTS’SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER PRIOR TO FABRICATION. GN5.0 STRUCTURAL STYROFOAM FILL: 1. STRUCTURAL STYROFOAM FILL NOTED IN DRAWINGS SHALL CONSIST OF EXTRUDED POLYSTYRENE (XPS) CONFORMING TO MINIMUM PHYSICAL PROPERTY REQUIREMENTS GIVEN IN ASTM C578, TABLE 1 FOR TYPE IV CLASSIFICATION. ST1.1 STRUCTURAL STEEL CONNECTION NOTES: 1. STEEL MEMBER END CONNECTION DESIGN ARE DELEGATED TO THE GENERAL CONTRACTOR OR THE GENERAL CONTRACTOR'S CHOSEN STEEL FABRICATOR PER SECTION "GN1.5 -DEFERRED SUBMITTALS" AND AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". MEMBER END CONNECTION DETAILS SHOWN IN THE STRUCTURAL DRAWINGS ARE GENERALIZED TO CONVEY FRAMING INTENT ONLY, AND ARE NOT MEANT FOR FABRICATION UNLESS SPECIFICALLY NOTED AS FULLY DESIGNED. 2. CONNECTIONS, SPLICES AND ERECTION PIECES SHALL BE DESIGNED AND DETAILED BY THE FABRICATOR’S STRUCTURAL ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT UNLESS INDICATED AS BEING FULLY DESIGNED ON THE STRUCTURAL DRAWINGS. THIS INCLUDES THE DESIGN, DETAIL, FURNISHING AND INSTALLATION OF STIFFENERS, CONTINUITY PLATES, DOUBLER PLATES, OR OTHER NECESSARY ADDITIONAL PARTS AS REQUIRED FOR LOCAL MEMBER STRENGTHENING. SHOP DRAWINGS AND CORRESPONDING CALCULATIONS, BOTH BEARING THE CONNECTION ENGINEER’S SEAL AND SIGNATURE, SHALL BE SUBMITTED FOR REVIEW FOR GENERAL CONFORMANCE WITH CONTRACT DOCUMENTS PRIOR TO FABRICATION. 3. SHOP AND FIELD CONNECTIONS SHALL BE MADE WITH HIGH STRENGTH BOLTS OR WELDS. HIGH STRENGTH BOLTS AND NUTS SHALL BE CLEARLY MARKED AS REQUIRED BY AISC SPECIFICATIONS. BOLTS SHALL BE A MINIMUM DIAMETER OF ¾”U.N.O.. FILLET WELD SIZES SHALL BE 1/16”SMALLER THAN THICKNESS OF THINNER MATERIAL BEING JOINED U.N.O.. 4. DESIGN SIMPLE SHEAR GRAVITY CONNECTIONS FOR FORCES INDICATED ON THE DRAWINGS. CONNECTION DESIGN FORCES INDICATED ON THE DRAWINGS ARE UNFACTORED U.N.O.. • FOR NON-COMPOSITE BEAM CONNECTIONS WHERE REACTIONS ARE OMITTED FROM THE DRAWINGS, DESIGN EACH END CONNECTION FOR 55% OF THE MAXIMUM TOTAL UNIFORM LOAD AS DEFINED IN THE AISC STEEL CONSTRUCTION MANUAL, TABLE 3-6. • FOR COMPOSITE BEAM CONNECTIONS WHERE REACTIONS ARE OMITTED FROM THE DRAWINGS, DESIGN EACH END CONNECTION FOR 100% OF THE MAXIMUM TOTAL UNIFORM LOAD AS DEFINED IN THE AISC STEEL CONSTRUCTION MANUAL, TABLE 3-6 FOR BEAMS WITH WEIGHT EQUAL TO OR LESS THAN 40 LBS/FT, AND 85% OF THE MAXIMUM TOTAL UNIFORM LOAD FOR BEAMS LARGER THAN 40 LBS/FT. • FOR MOMENT CONNECTIONS WHERE MOMENT REACTION IS OMITTED FROM THE DRAWINGS, DESIGN FOR THE FULL PLASTIC MOMENT CAPACITY OF THE BEAM IN ADDITION TO THE SHEAR VALUES NOTED ABOVE. 5. BRACE AND / OR TRUSS CONNECTIONS SHALL BE DESIGNED TO DEVELOP BOTH THE MAXIMUM TENSILE AND COMPRESSIVE CAPACITY OF THE MEMBER SIZES SHOWN, UNLESS CONNECTION DESIGN FORCES ARE SPECIFICALLY NOTED IN THE STRUCTURAL DRAWINGS. BRACE AND / OR TRUSS DESIGN FORCES PROVIDED ARE UNFACTORED U.N.O.. 6. STEEL MEMBERS 6”DEEP AND GREATER SHALL HAVE NO CONNECTION CONSIST OF LESS THAN (2) ¾”DIA. A325-N BOLTS OR WELDS DEVELOPING LESS THAN 10 KIPS ALLOWABLE CAPACITY. MINIMUM WELD SIZE SHALL BE A 3/16”FILLET WELD, OR MIN. PER ACIS D1.1, WHICHEVER IS LARGER. 7. MEMBER WORK POINTS FOR CONNECTION DESIGN AND DETAILING OCCUR AT INTERSECTIONS OF MEMBER CENTERLINES, U.N.O.. 8. OVERSIZED OR SLOTTED BOLT HOLES SHALL NOT BE USEDFOR CONNECTIONS UNLESS SPECIFICALLY INDICATED IN THE STRUCTURAL CONTRACT DOCUMENTS OR APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. 9. CONNECTIONS OCCURING THROUGH EXPANSION JOINTS SHALL PROVIDE FREE MOVEMENT AS INDICATED IN THE STRUCTURAL DETAILS. BOLTS IN SLOTTED HOLES SHALL BE UTILIZED AND SHALL BE NO MORE THAN FINGER TIGHTENED WITH THREADS CRIMPED U.N.O.. 10. SLIP CRITICAL BOLTS AND BOLTS SUBJECT TO DIRECT TENSION SHALL UTILIZE DIRECT TENSION INDICATORS OR APPROVED EQUIVALENT TO ENSURE CORRECT PRE-TENSION IS APPLIED PER AISC “MANUAL OF STEEL CONSTRUCTION”. 11. SHOP AND FIELD CONNECTIONS ARE TO BE INSPECTED BY AN INDEPENDENT TESTING LABORATORYFOR PROPER MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH SECTION "GN5.0 -SPECIAL INSPECTIONS" AND THE GOVERNING BUILDING CODE. 12. BOLTED BEAM CONNECTIONS SHALL USE ASTM F3125 GR. A325 OR A490 BOLTS AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS". SIMPLE FRAMED SHEAR CONNECTIONS SHALL CONSIST OF "SNUG-TIGHTENED JOINTS" WHICH ENSURE THAT THE PLIES OF CONNECTED MATERIAL HAVE BEEN BROUGHT INTO FIRM CONTACT AND SHALL BE INSTALLED AND VISUALLY INSPECTED PER SECTIONS 8.1 AND 9.1 RESPECTIVELY OF THE "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS." VISUAL INSPECTION OF BOLTED CONNECTIONS SHALL BE PERFORMED BY AN INDEPENDENT TESTING AGENCY. DIRECT TENSION INDICATOR (DTI) BOLTS SHALL BE PERMITTED. 13. WELDING INCLUDING WELDING ELECTRODES, WELDING PROCESS, MINIMUM PREHEAT AND INTERPASS TEMPERATURES SHALL BE IN ACCORDANCE WITH THE AISC AND AWS SPECIFICATIONS. ANY STRUCTURAL STEEL DAMAGED IN WELDING IS TO BE REPLACED OR REINFORCED AS APPROVED BY THE STRUCTURAL ENGINEER. WELDERS SHALL HOLD VALID CERTIFICATES IN ACCORDANCE WITH SECTION 4 OF THE AWS D1.1 "STRUCTURAL WELDING CODE-STEEL" AND HAVE CURRENT EXPERIENCE IN THE TYPE OF W ELDS AS SHOWN IN THE STRUCTURAL CONTRACT DOCUMENTS. THE STRUCTURAL ENGINEER MAY REQUEST EVIDENCE OF SUCH QUALIFICATIONS AT ANY TIME DURING THE PROJECT. WELDS SHALL BE PERFORMED USING E70XX SERIES LOW HYDROGEN RODS U.N.O.. WELDS SHALL BE INSPECTED BY AN INDEPENDENT TESTING AGENCY IN ACCORDANCE WITH THE AISC AND AWS SPECIFICATIONS. 14. COMPLETE JOINT PENETRATION WELDS SHALL HAVE ULTRASONIC TESTING PERFORMED BY THE OWNER’S QUALITY ASSURANCE INSPECTOR IN ACCORDANCE WITH AWS D1.1. FAILURES SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 15. REMOVE WELD BACKER BARS AND GRIND SMOOTH AFTER WELD IS COMPLETED U.N.O. 16. WELD LENGTHS SHALL BE CONTINUOUS U.N.O.. 17. GROOVE WELDS NOTED IN STRUCTURAL CONTRACT DOCUMENTS SHALL BE COMPLETE JOINT PENETRATION U.N.O.. 18. DIRECT CONTACT JOINTS BETWEEN TWO MEMBERS SHALL BE WELDED TO DEVELOP THE ALLOWABLE TENSILE CAPACITY OF THE SMALLER MEMBER U.N.O.. GN4.0 STAIR & HANDRAIL NOTES: 1. STAIRS AND HANDRAILS SHALL BE DESIGNED BY AN ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT. SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED FOR REVIEW AND COORDINATION PRIOR TO CONSTRUCTION. 2. SHOP DRAWINGS SHALL INCLUDE DESIGN CRITERIA, FRAMING SIZES AND DETAILING FOR ALL MEMBERS AND CONDITIONS, AND CONNECTIONS TO SUPPORT STRUCTURE. 3. CONNECTIONS TO SUPPORT STRUCTURE SHALL BE DETAILED SUCH THAT THEY DO NOT INDUCE TORSION AND/OR LOAD ECCENTRICITY TO SUPPORTING FRAMING MEMBERS. PROVIDE ADDITIONAL BRACING AS REQUIRED TO MITIGATE EFFECTS OF TORSION ON INDIVIDUAL SUPPORT MEMBERS. 4. STAIRS SHALL BE DESIGNED TO SUPPORT 100 POUNDS PER SQUARE FOOT LOAD OVER ENTIRE AREA. TREADS SHALL ALSO BE DESIGNED TO SUPPORT 300 POUNDS CONCENTRATED LOAD LOCATED SO AS TO PRODUCE THE MAXIMUM LOAD EFFECT IN THE MEMBERS. 5. HANDRAILS AND GUARDS SHALL BE DESIGNED TO WITHSTAND A UNIFORM LOAD OF 50 PLF APPLIED HORIZONTALLY, OR A CONCENTRATED LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION SO AS TO PRODUCE THE MAXIMUM LOAD EFFECT IN THE MEMBERS. INTERMEDIATE RAILS, PANEL FILLERS AND THEIR CONNECTIONS SHALL BE DESIGNED TO WITHSTAND A LOAD OF 50 PSF APPLIED HORIZONTALLY OVER THE ENTIRE TRIBUTARY AREA, INCLUDING OPENINGS AND SPACES BETWEEN RAILS. 6. REFER TO ARCHITECTURAL DRAWINGS FOR STAIR AND HANDRAIL LAYOUT AND DIMENSIONS. LOOSE STEEL LINTEL SCHEDULE -MASONRY VENEER 1 MIN. LINTEL2 SIZE (LLV) MAXIMUM CLEAR SPAN4 (FT) MINIMUM BEARING LENGTH3 L3 1/2 x 3 1/2 x 1/44'-0"4" L4 x 3 1/2 x 1/46'-0"4" L4 x 3 1/2 x 3/88'-0"8" L6 x 3 1/2 x 3/810'-0"8" L8 x 4 x 7/1612'-0"12" LINTEL SCHEDULE NOTES: 1. SCHEDULED LINTELS SHALL BE USED WITH 4" NOMINAL WIDTH BRICK MASONRY ONLY. 2. ALL STEEL LINTELS SHALL BE HOT DIPPED GALVANIZED, INSTALLED LONG LEG VERTICAL (LLV). 3. MINIMUM BEARING LENGTH MEASURED FROM FACE OF OPENING TO END OF LINTEL. 4. MAXIMUM CLEAR SPAN MEASURED FACE TO FACE OF SUPPORTED OPENING. 5. PROVIDE GALVANIZED BRICK TIES @ 24" O.C. MAX. WITH (1) TIE MIN. PER 2.67 SQ FEET OF WALL AREA. 6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION AND SIZE OF BRICK EXPANSION JOINTS WHERE OCCURS, TYP. 7. PROVIDE WEEPHOLES @ 24" O.C. MAX. IN HEAD JOINTS IMMEDIATELY ABOVE FLASHING. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFO. 8. REFER TO PROJECT SPECIFICATIONS FOR ALL OTHER INFORMATION, TYP. 9. ALL OUT OF PLANE LATERAL FORCES RESISTED BY BACKUP WALL FRAMING, SEE PLANS FOR MORE INFORMATION. 10. BRICK SHALL NOT OVERHANG THE TOE OF THE STEEL ANGLE BY MORE THAN 1 INCH. GN8.0 MASONRY VENEER LOOSE LINTEL SCHEDULE: SNOW DRIFT LOAD FLAT ROOF SNOW LOAD ROOF TRUSS TO BE DESIGNED FOR ALL CUMULATIVE LOADING FINISHED ROOF LINE FINISHED ROOF LINE HIGH ROOF STRUCTURE OR PARAPET Pd = 57 PSF w = 12' - 9"0'-0" TO 6'-0"25 PSF SNOW DRIFT LOAD FLAT ROOF SNOW LOAD ROOF TRUSS TO BE DESIGNED FOR ALL CUMULATIVE LOADING FINISHED ROOF LINE FINISHED ROOF LINE HIGH ROOF STRUCTURE OR PARAPET Pd = 35 PSF 7' - 0".25 PSF 7' - 0".UP TO 13'-0"ROOF DIFFERENTIALScale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:15:12 PMS0.101 General Notes Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/2" = 1'-0"2 Snow Drift Loading Schematic 1/2" = 1'-0"3 Snow Drift Loading Schematic @ Rooftop Mech. Wells A A No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 A Permit Revisions 02/09/26 100% IFC 03/18/26 SHRINKAGEEXPANSIONSHRINKAGEAIR DRYWATER 3" MIN.6d6d 1 6 2 1/2" MIN. 4d OR 12d1 3 5 ° D D D D D D d45°d BAR #3 #4 #5 #6 #7 #8 #9 #18 #10 #11 #14 D STIRRUPS / TIES d BAR BENDING TABLE 3/8"1 1/2" 1/2"2" 5/8"2 1/2" 3/4"4 1/2" 7/8"5 1/4" 1"6" 1 1/8"- 1 1/4"- 1 3/8"- 1 3/4"- 2 1/4"- BAR BENDING FOR REINFORCING BAR STANDARD HOOKS BAR BENDING FOR STIRRUPS AND TIE HOOKS BAR BENDING FOR REINFORCING BAR OFFSET d REBAR BENDING DIAGRAM D REINF BAR STD HOOKS 2 1/4" 3" 3 3/4" 4 1/2" 5 1/2" 6" 9 1/2" 10 3/4" 12" 18 1/4" 24" CC1.0 CONCRETE AND CONCRETE REINFORCEMENT: 1. STRUCTURAL CONCRETE SHALL BE LABORATORY DESIGNED AND SHALL CONFORM TO THE LATEST EDITION OF ACI 318 AND ACI 301, BY THE AMERICAN CONCRETE INSTITUTE. MIX DESIGNS FOR EACH TYPE AND STRENGTH SHALL BE ESTABLISHED BY THE SUPPLIER AND SUBMITTED FOR APPROVAL A MINIMUM OF 15 BUSINESS DAYS PRIOR TO THE COMMENCEMENT OF WORK. ADJUSTMENTS MADE TO ALREADY APPROVED MIX DESIGNS, INCLUDING CHANGES IN ADMIXTURES, SHALL BE SUBMITTED IN WRITING FOR APPROVAL PRIOR TO FIELD USE. CONCRETE DESIGNED TO BE PUMPED SHALL BE NOTED AS SUCH IN MIX DESIGNS SUBMITTED FOR REVIEW. 2. CONCRETE TO BE USED IN POST-TENSIONED CONSTRUCTION OF ELEMENTS CARRYING ONE FLOOR OF LOAD (SLABS, BEAMS, ETC.) SHALL BE PROPORTIONED TO REACH 60% (MINIMUM) OF SPECIFIED 28-DAY STRENGTH WITHIN 72 HOURS AFTER CONCRETE PLACEMENT TO ALLOW FOR TIMELY STRESSING OF TENDONS. CONCRETE TO BE USED IN POST-TENSIONED CONSTRUCTION OF ELEMENTS CARRYING TWO OR MORE FLOORS OF LOAD (PODIUMS, TRANSFER GIRDERS, ETC.) SHALL BE PROPORTIONED TO REACH 75% (MINIMUM) OF SPECIFIED 28-DAY STRENGTH WITHIN 72 HOURS AFTER CONCRETE PLACEMENT. CONTRACTOR SHALL SUBMIT HISTORICAL BREAK DATA AS NEEDED TO CONFIRM EARLY STRENGTH GAIN IN ADDITION TO DATA REQUIRED BY ACI 318, CHAPTER 5. 3. FORMWORK, SHORING AND RESHORING SHALL BE DESIGNED, ERECTED AND MAINTAINED ACCORDING TO ACI 301 AND ACI 347 TO WITHSTAND NATURAL AND CONSTRUCTION LOADS APPLIED PRIOR TO CONCRETE STRUCTURE REACHING ITS DESIGN STRENGTH. SHOP DRAWINGS SHOWING LAYOUT AND PROCEDURE OF FORMWORK, SHORING AND RESHORING, AS WELL AS CORRESPONDING CALCULATIONS, EACH BEARING THE SEAL AND SIGNATURE OF THE FORMWORK/SHORING ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT, SHALL BE SUBMITTED FOR REVIEW PRIOR TO CONSTRUCTION. RESHORING SHALL EXTEND A MINIMUM OF TWO FLOORS BELOW FLOOR SUPPORTING FALSEWORK (OR GROUND FLOOR). 4. CONCRETE REINFORCEMENT SHALL BE NEW DEFORMED BILLET STEEL AND SHALL BE FREE OF DIRT, OIL OR OTHER BOND INHIBITING MATERIAL U.N.O.. A. FOR SEISMIC DESIGN CATEGORY A, B, C (SEE GENERAL NOTES FOR CATEGORY): • REINFORCING BARS SHALL CONFORM TO ASTM A 615, GRADE 60 FOR #6 AND SMALLER, AND GRADE 75 FOR #7 AND LARGER. WELDABLE REINFORCING BARS SHALL CONFORM TO ASTM A706, GR. 60 U.N.O.. B. FOR SEISMIC DESIGN CATEGORY D, E, F (SEE GENERAL NOTES FOR CATEOGORY): • REINFORCING BARS SHALL CONFORM TO ASTM A706 GRADE 60 OR ASTM A615 GRADE 60 TYPICAL UNO. EXCEPTIONS INCLUDE HORIZONTAL REINFORCING IN FOUNDATION ELEMENTS, HOOP / TIE REINFORCING IN COLUMNS AND SHEAR WALL BOUNDARY ELEMENTS, AND CHORD AND COLLECTOR REINFORCEMENT IN ELEVATED SLABS WHICH SHALL CONFORM TO ASTM A706 GRADE 80 UNLESS NOTED OTHERWISE ON THE DRAWINGS. IN ADDITION, ASTM A615 GRADE 60 USED AS LONGITUDINAL REINFORCEMENT IN SPECIAL MOMENT FRAME COLUMNS/BEAMS AND SPECIAL REINFORCED SHEAR WALLS INCLUDING COUPLING BEAMS SHALL CONFORM TO THE ADDITIONAL REQUIREMENTS OF ACI 318 SECTION 20.2.2.5. CONTRACTOR SHALL SUBMIT MILL CERTIFICATES FOR ALL REINFORCING INDICATING PHYSICAL AND CHEMICAL PROPERTIES TO ENGINEER FOR REVIEW PRIOR TO FABRICATION. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185, GRADE 70. 6. EPOXY COATED REINFORCING BARS NOTED IN THE STRUCTURAL DRAWINGS SHALL CONFORM TO ASTM A775. 7. DEFORMED BAR ANCHORS NOTED IN THE STRUCTURAL DRAWINGS SHALL CONFORM TO ASTM A1064 GRADE 70 U.N.O.. 8. DETAIL REINFORCING BARS AND PROVIDE BAR SUPPORTS AND SPACERS IN ACCORDANCE WITH ACI 315. SUBMIT SHOP DRAWINGS FOR APPROVAL WHICH ACCURATELY DEPICT THE REINFORCING BAR SIZES AND PLACEMENT AS SPECIFIED IN THE STRCUTURAL DRAWINGS. WRITTEN DESCRIPTION OF REINFORCEMENT WITHOUT CLARIFYING SECTIONS, ELEVATIONS, AND DETAILS SHALL NOT ACCEPTED. 9. REINFORCING BAR BENDS SHALL BE MADE COLD. FIELD BENDING SHALL NOT BE PERMITTED U.N.O.. NO WELDING OF REINFORCING BARS OR TORCHING TO BEND REINFORCING BARS SHALL BE PERMITTED U.N.O.. 10. REINFORCING SHALL BE PROPERLY CHAIRED AND TIED PER ACI 315 (SP66) AND CRSI (PLACING REINFORCING BARS) PRIOR TO PLACING CONCRETE. 11. CONCRETE SHALL BE NORMAL WEIGHT STONE AGGREGATE CONCRETE UNLESS NOTED OTHERWISE. AGGREGATE SHALL MEET ASTM C33 REQUIREMENTS, AND SHALL BE 3/4" TO 1 1/2" NOMINAL AGGREGATE SIZE. CONCRETE ON METAL DECK IS TO UTILIZE 3/8" PEA GRAVEL COURSE AGGREGATE. PROVIDE ADMIXTURES AS REQUIRED TO IMPROVE WORKABILITY. THE GENERAL CONTRACTOR SHALL COORDINATE SLUMP REQUIREMENTS UNLESS NOTED OTHERWISE IN STRUCTURAL DOCUMENTS. PLASTIC CONCRETE TEMPERATURE SHALL NOT EXCEED 90 DEGREES PRIOR TO PLACEMENT. THE WATER:CEMENT RATIO SHALL NOT EXCEED THE RATIOS SHOWN BELOW. THE FLYASH CONTENT SHALL NOT EXCEED THE PERCENTAGE OF CEMENTITIOUS MATERIALS SHOWN BELOW. 12. CONCRETE CONSTRUCTION SHALL MEET THE FOLLOWING REQUIREMENTS U.N.O.: STRUCTURAL ELEMENT MIN. COVER FOUNDATIONS: • FOOTINGS MIN COMPRESSIVE STRENGTH (psi) • GRADE BEAMS • SLAB-ON-GRADE • RETAINING WALL 3”ALL SURFACES 1 ½”TOP / 3”ELSE 1 ½”TOP & BOT 2”EXT / 3/4”INT TEST AGE (DAYS) MAX. W/CM RATIO MAX FLY ASH CONTENT ELASTIC MODULUS SHRINKAGE LIMIT ADDITIONAL MIX NOTES 3,000 3,000 3,000 4,000 56 28 28 28 SEE TABLE SEE TABLE SEE TABLE SEE TABLE 50% 30% 20% 30% 57,000 57,000 57,000 57,000 N/A N/A N/A N/A 1. THIS MIX TO CONTAIN POLYPROPYLENE OR NYLON FIBROUS REINFOREMENT AT THE MANUFACTURE'S RECOMMENDED DOSAGE. 2. THIS MIX SHALL BE HIGH SLUMP OR SELF CONSOLIDATING CONCRETE (SCC) TO FACILITATE PLACEMENT. 3. THIS MIX SHALL HAVE A HIGH SHRINKAGE LIMIT OF 0.045% AT 28 DAYS. CONFIRM TO REQUIRMENTS LISTED UNDER SHRINKAGE.. 4. THIS MIX SHALL BE DESIGNED TO MINIMIZE HEAT OF HYDRATION -SEE NOTE CC4.0 MASS CONCRETE PLACEMENT AND TEMPERATURE MONITORING. 5. THIS MIX SHALL BE MONITORED FOR MAXIMUM AND DIFFERENTIAL TEMPERATURES IN ACCORDANCE WITH ACI GUIDELINES FOR PLACEMENT OF MASS CONCRETE WHERE NOTED ON PLAN -SEE NOTE CC4.0 MASS CONCRETE PLACEMENT AND TEMPERATURE MONITORING. 6. REFERENCE ARCHITECTURAL ELEVATIONS FOR APPLICABLE LOCATIONS. SEE NOTE CC1.3 EXPOSED CONCRETE FOR CONCRETE REQUIREMENT. 7. THIS MIX TO CONTAIN "XYPEX ADMIX C-SERIES" OR ALTERNATE APPROVED CRYSTALLINE WATERPROOFING ADMIXTURE. MIX NOTES CC1.1 CONCRETE SAMPLING: 1. A SET OF CYLINDERS FOR COMPRESSIVE STRENGTH TESTS SHALL BE MOLDED AND LAB CURED IN ACCORDANCE WITH ASTM C 31 BY THE OWNER'S INDEPENDENT TESTING LAB AT THE FREQUENCY SPECIFIED IN THESE DRAWINGS, OR AS NOTED IN ACI 318 AND THE GOVERNING BUILDING CODE, WHICHEVER IS GREATER. EACH SET OF COMPRESSION TESTS SHALL CONSIST OF A MINIMUM OF FOUR STANDARD TEST CYLINDERS U.N.O.. COMPRESSION STRENGTH TESTS SHALL BE PERFORMED IN ACCORDANCE WITH ASTM C39 AND RESULTS SHALL BE REPORTED TO THE ENGINEER WITHIN 24 HOURS OF TESTING. 2. FIELD SAMPLES FOR STRENGTH TESTS SHALL BE TAKEN IN ACCORDANCE WITH ASTM C172 AND SHALL CONSIST OF A MINIMUM NUMBER OF STANDARD TEST CYLINDERS PER SET TAKEN AT FREQUENCY AS NOTED BELOW: • ELEMENT # CYLINDERS SAMPLE SET FREQUENCY • MAT FNDN 4 PER SET U.N.O.PER 250 CU YDS • PIERS 4 PER SET U.N.O.PER 50 CU YDS • PILES 4 PER SET U.N.O.PER 50 CU YDS/PER PILE GROUP BENEATH EA. COL / WALL • BASEMENT WALL 4 PER SET U.N.O.PER 150 CU YDS • FOOTING & PILE CAP 4 PER SET U.N.O.PER 50 CU YDS • SLAB ON GRADE 4 PER SET U.N.O.PER 150 CU YDS / PER 5000 SQ FT FLOOR AREA • MILD SLAB 4 PER SET U.N.O.PER 150 CU YDS / PER 5000 SQ FT FLOOR AREA • P.T. SLAB 6 PER SET U.N.O.PER 150 CU YDS / PER 5000 SQ FT FLOOR AREA • COL/SW (28 DAY f’c)4 PER SET U.N.O.PER 50 CU YDS / MIN. 2 PER FLOOR • COL/SW (56 DAY f’c)6 PER SET U.N.O.PER 50 CU YDS / MIN. 2 PER FLOOR • OTHERS 4 PER SET U.N.O.PER 150 CU YDS / MIN. 1 SET PER CLASS PER DAY 3. NO MORE THAN ONE SET OF CYLINDERS AT A TIME SHALL BE MADE FROM ANY SINGLE TRUCK. 4. A MINIMUM OF FIVE SETS OF CYLINDERS SHALL BE TAKEN AND TESTED FOR EACH CLASS OF CONCRETE. 5. IF MORE THAN ONE BATCH PLANT IS USED TO SOURCE CONCRETE, THE FREQUENCIES CITED ABOVE SHALL APPLY FOR EACH PLANT USED. SEE SCHEDULE MIN. EMBEDMENT CIP COLUMN / WALL CIP SLAB / BEAM TYPICAL HOOKED BAR EMBEDMENT CIP SLAB / FOOTING CIP COLUMN / WALL STANDARD 90° HOOK STANDARD 180° HOOK STANDARD 90° HOOK STANDARD 180° HOOK SEE SCHEDULEMIN. EMBEDMENTCC1.3 EXPOSED CONCRETE NOTES: 1. NO FLY ASH SHALL BE USED IN ARCHITECTURALLY EXPOSED CONCRETE WITHOUT PRIOR APPROVAL FROM ARCHITECT. 2. PROVIDE A FINISH OF "SF-2.0" OR BETTER AS DEFINED BY ACI FOR ARCHITECTURALLY EXPOSED CONCRETE AND SEAL WITH A WATER BASED ACRYLIC SEALER APPROVED BY THE OWNER / ARCHITECT. 3. ARCHITECTURALLY EXPOSED CONCRETE SHALL BE FORMED WITH MDO BOARD WHICH IS REPLACED AT SUFFICIENT INTERVALS TO ENSURE CONSISTENT QUALITY AND FINISH. CEILINGS SHALL HAVE TIGHT BUTT JOINTS. JOINTS SHALL NOT BE GROUND UNLESS MISALIGNMENT EXCEEDS A.C.I. STANDARDS AND OWNER IS CONSULTED AND APPROVES. 4. ARCHITECTURALLY EXPOSED CONCRETE COLUMNS, COLUMN TRANSITION CAPS, BEAMS, SLAB EDGES, AND WALLS SHALL BE FORMED WITH A 3/4" CHAMFER AT EACH EDGE. 5. ALL EXPOSED TO VIEW CONCRETE ELEMENTS TO HAVE A 28 DAY SHRINKAGE LIMIT OF 0.040% 6. EXPOSED TO VIEW CONCRETE ELEMENTS POURED WITH HIGHER STRENGTH CONCRETE THAN 4,000 PSI SHALL UTILIZE AN APPROVED SHRINKAGE REDUCING ADMIXTURE PER MANUFACTURES RECOMMENDATIONS TO LIMIT SHRINKAGE TO 0.040% AS NOTED ABOVE. TYPICAL REBAR LAP SPLICE DETAIL PER SCHEDULES MINIMUM LAP SPLICE LENGTH PREFERRED SPLICE LAYOUT MAX PERMITTED OFFSET PER SCHEDULES MINIMUM LAP SPLICE LENGTH OR 6"SMALLER OF ℓd / 57 DAYS14 DAYS21 DAYS28 DAYS35 DAYSCC1.2 CONCRETE SHRINKAGE: 1. ALTERNATIVELY, CONFIRM TO THE FOLLOWING MAXIMUM ALLOWABLE WATER CONTENT IN LIEU OF SHRINKAGE TESTING: • FOR INTERMEDIATE VALUES, USE LINEAR INTERPOLATION. • MAXIMUM ALLOWABLE WATER CONTENT SHALL BE TOTAL WATER IN THE MIX AT THE TIME OF PLACING, INCLUDING WATER ADDED AT THE SITE. • FOR SPECIFIED 28 DAY SHRINKAGE LIMITS BELWO 0.030%, A SHRINKAGE REDUCING ADMIXTURE IS REQUIRED: SPECIFIED 28 DAY SHRINKAGE LIMIT MAXIMUM ALLOWABLE WATER CONTENT (LBS PER CUBIC YARD) 0.040% 0.045% 0.035% 245 255 235 CC1.0 CONCRETE AND CONCRETE REINFORCEMENT (CONTINUED): CURING DEFINITION IMMEDIATELY AFTER SCREEDING CONCRETE, APPLY AN EVAPORATIVE REDUCER TO ALL EXPOSED SURFACES IN ACCORDANCE WITH MANUFACTURE'S RECOMMENDATIONS C1 IMMEDIATELY AFTER STRIPPING FORMS, APPLY A LIQUID MEMBRANE-FORMING CURING COMPOUND TO ALL EXPOSED SURFACES. ALTERNATIVELY, COVER WITH POLYETHYLENE SHEETING OR BURLAP-POLYETHYLENE SHEETING IN DIRECT CONTACT WITH CONCRETE. FOR FORMED SURFACES, THESE REQUIREMENTS MAY BE OMMITED IF FORMS REMAIN IN CONTACT WITH CONCRETE FOR 7 DAYS OR MORE. C2 IMMEDIATELY AFTER FINISHING, APPLY A LIQUID MEMBRANE-FORMING CURING COMPOUND TO TOP SURFACE OF MAT AND COVER WITH BLANKETS FOR 7 DAYS MINIMUM. C3 NO SPECIAL CURING PROCEDURES REQUIREDC4 C1 = SLAB ON GRADE AND ELEVATED SLABS C2 = COLUMNS AND WALLS C3 = MAT FOUNDATION C4 = ALL OTHER CONCRETE 13. CONCRETE SHRINKAGE SHALL BE MEASURED AND RECORDED IN ACCORDANCE WITH ASTM C157 WITH 7- DAY WATER CURE AND 21-DAY AIR DRY CURE. FINAL LENGTH CHANGE MEASUREMENT SHALL BE TAKEN 28 DAYS AFTER 7-DAY WATER CURE FOR A TOTAL 35-DAY TEST DURATION. TOTAL SHRINKAGE SHALL BE LESS THAN THE SPECIFIED SHRINKAGE LIMIT IN TABLE ABOVE AND GENERAL NOTE CC1.2 CONCRETE SHRINKAGE 14. CLOSURE POUR CONCRETE SHALL HAVE A SHRINKAGE LIMIT OF 0.025% AT 28 DAYS. USE 1.0 GAL / CU YD OF ECLIPSE SHRINKAGE REDUCING ADMIXTURE BY WR GRACE, OR APPROVED EQUAL ALTERNATE. (ALTERNATE TO BE SUBMITTED TO EOR FOR APPOVAL) 15. PORTLAND CEMENT SHALL CONFORM TO ASTM C150, TYPE I OR II. 16. FLYASH SHALL CONFORM TO ASTM C618, TYPE C OR F. 17. WATER SHALL NOT BE ADDED TO THE CONCRETE AT THE JOBSITE UNLESS EXPLICITLY NOTED ON BATCH TICKET AS BEING WITHHELD AT BATCH PLANT. FINAL WATER CONTENT AT PLACEMENT SHALL NOT EXCEED WATER CONTENT SPECIFIED IN APPROVED MIX DESIGNS. 18. MECHANICAL AND ELECTRICAL CONDUIT SHALL NOT BE PLACED IN BEAMS PARALLEL TO BEAM REINFORCING. PROVIDE A MINIMUM OF 1 1/2" CLEAR BETWEEN CONDUIT AND PARALLEL REINFORCING. DO NOT "BUNDLE" CONDUITS. CONDUITS SHALL BE PLACED IN THE MIDDLE ONE THIRD OF THE SLAB THICKNESS OR BEAM DEPTH. SEE TYPICAL DETAILS FOR ADDITIONAL INFORMATION. 19. SET AND BUILD INTO FORM WORK ANCHORAGE DEVICES AND OTHER EMBEDDED ITEMS REQUIRED FOR OTHER WORK THAT IS ATTACHED TO OR SUPPORTED BY CAST-IN-PLACE CONCRETE. REBAR PROJECTING FROM CONCRETE SHALL BE SECURED IN PLACE PRIOR TO PLACING CONCRETE. 20. IF NOT SHOWN ON PLAN, THE CONTRACTOR SHALL SUBMIT A PROPOSED CONSTRUCTION JOINT LAYOUT FOR REVIEW. MAXIMUM SQUARE FOOTAGE PER POUR SHALL NOT EXCEED 15,000 UNLESS APPROVED BY ENGINEER. 21. UNLESS NOTED OTHERWISE ON PLAN, SLAB-ON-GRADE CONTROL JOINTS SHALL BE LOCATED AT APPROXIMATELY 400 SQ FT GRIDS. ACTUAL LOCATIONS SHALL BE SUBMITTED BY THE CONTRACTOR FOR REVIEW AND APPROVAL PRIOR TO PLACEMENT. SEE TYPICAL DETAILS FOR ADDITIONAL INFORMATION. 22. THE OWNER'S INDEPENDENT TESTING LABORATORY SHALL VERIFY AND PROVIDE WRITTEN DOCUMENTATION OF THE FOLLOWING: A. BATCH TICKETS FOR EACH TRUCK MATCHES THE APPROVED MIX DESIGNS, B. MEASURED SLUMP CONFORMS TO THAT NOTED IN APPROVED MIX DESIGNS, C. PLACEMENT OPERATIONS ARE IN ACCORDANCE WITH ACI SPECIFICATIONS, D. CONTROL JOINTS ARE INSTALLED WITHIN ACI TIME ALLOWANCE, E. PROPER CURING METHODS ARE UTILIZED. 23. CONSTRUCTION VEHICLE LOADS SHALL NOT BE PERMITTED ON ELEVATED SLABS WITHOUT WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. 24. ALUMINUM SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE, EITHER ELEVATED OR GRADE SUPPORTED. 25. HORIZONTAL CONSTRUCTION JOINTS ARE NOT PERMITTED IN ANY CONCRETE CONSTRUCTION UNLESS SPECIFICALLY NOTED IN THE STRUCTURAL DRAWINGS. 26. FLOOR CHASES, SLEEVES AND SHAFTS ARE TO BE FORMED PRIOR TO CONCRETE PLACEMENT. CORING AND SAW CUTTING OF CONCRETE AFTER PLACEMENT SHALL NOT BE PERMITTED. 27. UNDER NORMAL CONDITIONS, REINFORCED CONCRETE AND POST-TENSIONED CONCRETE DEVELOPS CRACKS. THE CRACKS ARE DUE TO THE INHERENT SHRINKAGE OF CONCRETE, CREEP, AND RESTRAINING EFFECTS OF WALLS AND OTHER STRUCTURAL ELEMENTS. 28. CURING A. TO CONFORM TO: • ACI 301, SECTION 5 • ACI 302, GUIDE TO CONCRETE FLOOR AND SLAB CONSTRUCTION • ACI 308, STANDARD SPECIFICATION FOR CURING B. CURING PROCEDURES TO BE IMPLIMINTED IMEDIATELY TO MAINTAIN CONCRETE IN A MOIST CONDITION AFTER PLACEMENT C. LIQUID MEMBRANE-FORMING CURING COMPOUNDS SHALL CONFORM TO ASTM C309 TYPE 1-D. CURING COMPOUNDS APPLIED TO SURFACES INTENDED TO RECIEVE FLOOR COVERINGS, PROTECTIVE COATINGS OR SEALERS, SHALL BE COMPATIBLE WITH THOSE PRODUCTS. APPLY COMPOUNDS IN ACCORDANCE WITH MANUFACTURE RECOMMENDATIONS. D. POLYETHYLENE SHEETING AND BURLAP-POLYETHYLENE SHEETING SHALL CONFORM TO ASTM C171. E. PROVIDE CURING AS FOLLOWS: NOTE:CONCRETE EXPOSED TO FREEZE / THAW CYCLES AND / OR CORROSIVE ENVIORNMENTS SHALL BE AIR ENTRAINED WITH A MAXIMUM W/ CM OF 0.40 REFER TO ACI 318 TABLE 19.3.3.1 EXPOSURE F2 FOR TARGET AIR CONTENT. CONCRETE f'c NON-AIR ENTRAINED CONCRETE MAX. WATER / CEMENT RATION (W/CM) FOR NW CONCRETE SCHEDULE 0.50 0.45 0.40 0.553,000 PSI 4,000 PSI 4,500 PSI 5,000 -10,000 PSI ADDITIONAL NOTES AT BUNDLED BARS 1. REINFORCEMENT DEVELOPMENT LENGTH SHOWN IN TABLE SHALL BE INCREASED BY 20 PERCENT WHEN SHOWN BUNDLED IN A GROUP OF THREE. 2. REINFORCEMENT DEVELOPMENT LENGTH SHOWN IN TABLE SHALL BE INCREASED BY 33 PERCENT WHEN SHOWN BUNDLED IN A GROUP OF FOUR. 3. BUNDLES LARGER THAN FOUR BARS ARE NOT PERMITTED. ADDITIONAL NOTES FOR LIGHT WEIGHT CONCRETE 1. REINFORCEMENT DEVELOPMENT LENGTH SHOWN IN TABLE SHALL BE INCREASED BY 33 PERCENT Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:15:18 PMS0.110 General Notes - Reinforcement Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 A B C DOWEL SCHEDULE DOWEL MARK DWL-A1 DWL-B1 DWL-B2 DWL-C2 CONFIG #5 #5 #4 A 48" 24" 24" #4 #4 #4 #5 B 24" 8" C - 36"8" 48"8" 48" 24" 48"-- 24" E D A B A B C D - - - - E - - - --- ---- -- ------ ---- ---- TYPE A TYPE B TYPE E A TYPE C TYPE D A B SIZE TYPE A TYPE B TYPE B TYPE B DWL-C1 DWL-A3 #3 S 24"24"TYPE A TYPE B DWL-B3 DWL-B4 -- TYPE C TYPE C -- (E)(D) NOTE: 1. S = SLAB / WALL THICKNESS MINUS REQUIRED COVERAGE DWL-A2 #3 8"24"24"TYPE A -- Class B SPLICE (ℓd = 1.3) -TO BE USED U.N.O. GRADE 60 UNCOATED BARS IN NORMAL WEIGHT CONCRETE (BLACK / GALVANIZED) BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 1'-10" #18 2'-5" 3'-0" 3'-7" 5'-3" 6'-0" 6'-9" 7'-7" 8'-5" 1'-7" 2'-1" 2'-7" 3'-1" 4'-6" 5'-2" 5'-10" 6'-7" 7'-3" MECH CPLR MECH CPLR 1'-5" 1'-11" 2'-4" 2'-10" 4'-1" 4'-8" 5'-3" 5'-11" 6'-6" 1'-4" 1'-9" 2'-2" 2'-7" 3'-9" 4'-3" 4'-9" 5'-4" 5'-11" Class A SPLICE (ℓd = 1.0) -TO BE USED ONLY WHEN SPECIFIED GRADE 60 UNCOATED BARS IN NORMAL WEIGHT CONCRETE (BLACK / GALVANIZED) BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 1'-5" #18 1'-10" 2'-4" 2'-9" 4'-0" 4'-7" 5'-2" 5'-10" 6'-6" 1'-3" 1'-7" 2'-0" 2'-5" 3'-6" 4'-0" 4'-6" 5'-1" 5'-7" 1'-1" 1'-5" 1'-10" 2'-2" 3'-2" 3'-7" 4'-0" 4'-6" 5'-0" 1'-0" 1'-4" 1'-8" 2'-0" 2'-10" 3'-3" 3'-8" 4'-2" 4'-7" CONCRETE STRENGTH (f`c=PSI)CONCRETE STRENGTH (f`c=PSI) MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR MECH CPLR Class B SPLICE (ℓd = 1.3) -TO BE USED U.N.O. GRADE 80 UNCOATED BARS IN NORMAL WEIGHT CONCRETE (BLACK / GALVANIZED) BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 2'-9" #18 3'-8" 4'-7" 5'-6" 8'-0" 9'-2" 10'-4" 11'-7" 12'-10" 2'-5" 3'-2" 4'-0" 4'-9" 6'-11" 7'-11" 8'-11" 10'-1" 11'-2" MECH CPLR MECH CPLR 2'-2" 2'-10" 3'-7" 4'-3" 6'-2" 7'-1" 8'-0" 9'-0" 10'-0" MECH CPLR MECH CPLR 2'-0" 2'-7" 3'-3" 3'-11" 5'-8" 6'-6" 7'-4" 8'-3" 9'-1" MECH CPLR MECH CPLR Class A SPLICE (ℓd = 1.0) -TO BE USED ONLY WHEN SPECIFIED GRADE 80 UNCOATED BARS IN NORMAL WEIGHT CONCRETE (BLACK / GALVANIZED) BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 2'-2" #18 2'-10" 3'-6" 4'-3" 6'-2" 7'-0" 7'-11" 8'-11" 9'-11" 1'-10" 2'-6" 3'-1" 3'-8" 5'-4" 6'-1" 6'-11" 7'-9" 8'-7" MECH CPLR MECH CPLR 1'-8" 2'-3" 2'-9" 3'-4" 4'-9" 5'-6" 6'-2" 6'-11" 7'-8" MECH CPLR MECH CPLR 1'-6" 2'-0" 2'-6" 3'-0" 4'-4" 5'-0" 5'-7" 6'-4" 7'-0" MECH CPLR MECH CPLR CONCRETE STRENGTH (f`c=PSI)CONCRETE STRENGTH (f`c=PSI) MECH CPLR MECH CPLR MECH CPLR MECH CPLR Class B SPLICE (ℓd = 1.3) -TO BE USED U.N.O. GRADE 80 COATED BARS IN NORMAL WEIGHT CONCRETE BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 4'-2" #18 5'-6" 6'-10" 8'-3" 12'-0" 13'-8" 15'-5" 17'-4" 19'-3" 3'-7" 4'-9" 5'-11" 7'-2" 10'-5" 11'-10" 13'-4" 15'-1" 16'-8" MECH CPLR MECH CPLR 3'-3" 4'-3" 5'-4" 6'-5" 9'-3" 10'-7" 12'-0" 13'-6" 14'-11" MECH CPLR MECH CPLR 2'-11" 3'-11" 4'-10" 5'-10" 8'-6" 9'-8" 10'-11" 12'-4" 13'-8" MECH CPLR MECH CPLR Class A SPLICE (ℓd = 1.0) -TO BE USED ONLY WHEN SPECIFIED GRADE 80 COATED BARS IN NORMAL WEIGHT CONCRETE BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 3'-2" #18 4'-3" 5'-3" 6'-4" 9'-3" 10'-6" 11'-11" 13'-4" 14'-10" MECH CPLR MECH CPLR 2'-9" 3'-8" 4'-7" 5'-6" 8'-0" 9'-2" 10'-4" 11'-7" 12'-10" MECH CPLR MECH CPLR 2'-6" 3'-4" 4'-1" 4'-11" 7'-2" 8'-2" 9'-3" 10'-4" 11'-6" MECH CPLR MECH CPLR 2'-3" 3'-0" 3'-9" 4'-6" 6'-6" 7'-6" 8'-5" 9'-6" 10'-6" MECH CPLR MECH CPLR MECH CPLR MECH CPLR CONCRETE STRENGTH (f`c=PSI)CONCRETE STRENGTH (f`c=PSI) Class B SPLICE (ℓd = 1.3) -TO BE USED U.N.O. GRADE 60 COATED BARS IN NORMAL WEIGHT CONCRETE BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 2'-9" #18 3'-7" 4'-6" 5'-5" 7'-10" 8'-11" 10'-1" 11'-4" 12'-7" 2'-4" 3'-1" 3'-11" 4'-8" 6'-9" 7'-9" 8'-9" 9'-10" 10'-11" MECH CPLR MECH CPLR 2'-1" 2'-10" 3'-6" 4'-2" 6'-1" 6'-11" 7'-10" 8'-10" 9'-9" MECH CPLR MECH CPLR 1'-11" 2'-7" 3'-2" 3'-10" 5'-7" 6'-4" 7'-2" 8'-0" 8'-11" MECH CPLR MECH CPLR Class A SPLICE (ℓd = 1.0) -TO BE USED ONLY WHEN SPECIFIED GRADE 60 COATED BARS IN NORMAL WEIGHT CONCRETE BAR SIZE 3,000 4,000 #3 #4 #5 #6 #7 #8 #9 #10 5,000 #11 #14 6,000 2'-1" #18 2'-9" 3'-6" 4'-2" 6'-0" 6'-11" 7'-9" 8'-9" 9'-8" MECH CPLR MECH CPLR 1'-10" 2'-5" 3'-0" 3'-7" 5'-3" 6'-0" 6'-9" 7'-7" 8'-5" MECH CPLR MECH CPLR 1'-8" 2'-2" 2'-8" 3'-3" 4'-8" 5'-4" 6'-0" 6'-9" 7'-6" MECH CPLR MECH CPLR 1'-6" 2'-0" 2'-6" 2'-11" 4'-3" 4'-11" 5'-6" 6'-2" 6'-10" MECH CPLR MECH CPLR CONCRETE STRENGTH (f`c=PSI)CONCRETE STRENGTH (f`c=PSI) MECH CPLR MECH CPLR MINIMUM EMBEDMENT WITH STANDARD 90° HOOK GRADE 60 UNCOATED BARS IN NORMAL WEIGHT CONCRETE (BLACK / GALVANIZED) BAR SIZE f'c=3,000 PSI f`c=4,000 PSI #3 #4 #5 #6 #7 #8 #9 #10 f`c=5,000 PSI #11 #14 f`c=6,000 PSI 0'-9" #18 1'-0" 1'-2" 1'-5" 1'-8" 1'-10" 2'-1" 2'-4" 2'-7" 0'-8" 0'-10" 1'-0" 1'-3" 1'-5" 1'-7" 1'-10" 2'-1" 2'-3" 2'-9" 3'-7" 0'-7" 0'-9" 0'-11" 1'-1" 1'-3" 1'-5" 1'-8" 1'-10" 0'-6" 0'-8" 0'-10" 1'-0" 1'-2" 1'-4" 1'-6" 1'-8" 1'-10" 3'-2" 4'-2" 2'-5" 3'-3" 2'-0" 2'-3" 2'-11" MINIMUM EMBEDMENT WITH STANDARD 90° HOOK GRADE 75-80 UNCOATED BARS IN NORMAL WEIGHT CONCRETE (BLACK / GALVANIZED) BAR SIZE f'c=3,000 PSI f`c=4,000 PSI #3 #4 #5 #6 #7 #8 #9 #10 f`c=5,000 PSI #11 #14 f`c=6,000 PSI 1'-0" #18 1'-3" 1'-6" 1'-10" 2'-1" 2'-4" 2'-8" 2'-11" 3'-3" 0'-10" 1'-1" 1'-3" 1'-7" 1'-10" 2'-0" 2'-4" 2'-8" 2'-10" 3'-6" 4'-6" 0'-9" 1'-0" 1'-2" 1'-5" 1'-7" 1'-10" 2'-1" 2'-4" 0'-8" 0'-10" 1'-1" 1'-3" 1'-6" 1'-8" 1'-11" 2'-1" 2'-4" 4'-0" 5'-3" 3'-1" 4'-1" 2'-6" 2'-10" 3'-8" MINIMUM EMBEDMENT WITH STANDARD 90° HOOK GRADE 60 COATED BARS IN NORMAL WEIGHT CONCRETE BAR SIZE f'c=3,000 PSI f`c=4,000 PSI #3 #4 #5 #6 #7 #8 #9 #10 f`c=5,000 PSI #11 #14 f`c=6,000 PSI 1'-2" #18 1'-6" 1'-9" 2'-2" 2'-6" 2'-9" 3'-2" 3'-6" 3'-11" 1'-0" 1'-3" 1'-6" 1'-11" 2'-2" 2'-5" 2'-9" 3'-2" 3'-5" 4'-2" 5'-5" 0'-11" 1'-2" 1'-4" 1'-8" 1'-11" 2'-2" 2'-6" 2'-9" 0'-9" 1'-0" 1'-3" 1'-6" 1'-9" 2'-0" 2'-3" 2'-6" 2'-9" 4'-9" 6'-3" 3'-8" 4'-11" 3'-0" 3'-5" 4'-5" MINIMUM EMBEDMENT WITH STANDARD 90° HOOK GRADE 75-80 COATED BARS IN NORMAL WEIGHT CONCRETE BAR SIZE f'c=3,000 PSI f`c=4,000 PSI #3 #4 #5 #6 #7 #8 #9 #10 f`c=5,000 PSI #11 #14 f`c=6,000 PSI 1'-9" #18 2'-3" 2'-8" 3'-3" 3'-9" 4'-2" 4'-9" 5'-3" 5'-11" 1'-6" 1'-11" 2'-3" 2'-11" 3'-3" 3'-8" 4'-2" 4'-9" 5'-2" 6'-3" 8'-2" 1'-4" 1'-9" 2'-0" 2'-6" 2'-11" 3'-3" 3'-9" 4'-2" 1'-2" 1'-6" 1'-11" 2'-3" 2'-8" 3'-0" 3'-5" 3'-9" 4'-2" 7'-2" 9'-5" 5'-6" 5'-11" 4'-6" 5'-2" 6'-8" No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 Embed Plate -Type A (WP-A) W EQ EQ LEQEQtPLATE WP-A4X4.1 4" 6" MARK W WP-A6X6.1 4" 6" L 3/8" 1/2" t DIA. ANCHORS (HSA) 1/2" 5/8" Embed Plate -Type C (WP-C) PLATE WP-C6X6.1 6" 8" W WP-C8X8.1 6" 8" L 3/8" 1/2" t DIA. ANCHORS (HSA) 2 2 1/2" 5/8" Embed Plate -Type D (WP-D) PLATE WP-D8X8.3 8" 10" MARK W WP-D10X10.2 8" 10" L 1/2" 3/4" t ANCHORS (HSA) Embed Plate -Type G (WP-G) W tWP-G12X16.1 WP-G12X18.1 WP-D12X12.1 L Embed Angle -Type A (WA-A) Embed Angle -Type B (WA-B) L bd tDLS1 E E S3 S3 E EQ EQ E LENGTH 4" 4" MARK LENGTH 4" 5" QUANTITY 1 1 QUANTITY Embed Plate -Type E (WP-E) W PLATE WP-E8X8.1 MARK WP-E8X10.1 ANCHORS (HSA) - - E 1 1/2" 1 1/2" E DIA.LENGTH QUANTITYE 4 4 5/8" 3/4" 5" 5" 1 1/2" 1 1/2" 12"12"1/2"41/2"3 1/2"1 1/2" PLATEMARK ANCHORS (HSA) 8" 8" W 8" 10" L 1/2" 1/2" t E1 1 1/2" 1 1/2" E2 3" 3" DIA.LGTH QTY 4 4 5/8" 5/8" 4" 4" W L t 12"16"1/2"1 1/2"EQEQEQE 12"18"1/2"1 1/2" WP-G12X20.1 12"20"1/2"1 1/2" WP-G12X24.1 12"24"1/2"1 1/2" WP-G12X30.1 12"30"1/2"1 1/2" WP-G12X36.1 12"36"3/4"1 1/2" E DIA.LENGTH QUANTITY 65/8"4" ROWS 3 6 8 10 12 3 4 5 6 7 14 4" 4" 4" 4" 4" 5/8" 5/8" 5/8" 5/8" 3/4" ANGLE WA-A4X4.1 MARK WA-A5X5.1 ANCHORS (HSA) WA-A6X6.1 4" 5" b 4" 5" d 5/16" 3/8" t E 1 1/2" 1 1/2" 6"4"3/8"1 1/2" DIA.LGTH QUANTITY 3 3 5/8" 3/4" 4" 5" 33/4"6" S2 ANGLE WA-B6X4.12 MARK WA-B5X5.12 ANCHORS (DBA) WA-B6X6.12 4" 5" b 6" 5" d 5/16" 3/8" t E 2" 2" 6"6"3/8"2" DIA.DL QTY 5/8" 3/4" 2'-0" 2'-0" 3/4"2'-0" WP-D8X8.2 8"8"1/2"45/8"4"1 1/2" WP-E12X12.2 12"12"3/4"1 1/2"3"43/4"6" WP-E10X10.1 10"10"3/4"1 1/2"3"43/4"4" E Embed Plate -Type B (WP-B) PLATE 8" MARK W WP-B8X5.1 5" L 1/2" t DIA. ANCHORS (HSA) 5/8" LENGTH 4"2 QUANTITY 1 1/2" E W tLE E EQEQ8"WP-B8X8.1 8"1/2"5/8"4"21 1/2" 8"WP-B8X8.2 8"1/2"3/4"5"21 1/2"td bL 1'-0" 1'-0" 1'-0" DBA HSA LGTH 4" 5" 6" DIA. 5/8" 3/4" 3/4" ANCHORS (HSA) 2 2 2 QTY 2 2 2EEROWSWP-D8X8.1 8"8"1/4"41/2"6"1 1/2" WP-D12X12.2 12"12"3/4"43/4"4"1 1/2" WP-D8X12.1 8"12"3/4"43/4"6"1 1/2" WA-A21/2x2 1/2.1 2 1/2"2 1/2"1/4"1 1/2"12" O.C.5/8"4"CONT WA-A5X3 1/2.1 5"3 1/2"5/16"1 1/2"12" O.C.3/4"5"CONT NOTE: 1. S = SLAB THICKNESS 2. C1= TOTAL SLAB THICKNESS -BOTT REBAR COVER 3. C2= COLUMN / WALL WIDTH -2" 8"WP-B8XS.1 S 1/2"5/8"4"21 1/2" Embed Plate -Type F (WP-F) WP-F12X12.1 PLATEMARK ANCHORS (HSA) W L t 12"10"3/4"3" E1 DIA.LGTH QTY 23/4"6" DL W DHANCHORS (DBA) E2E1E3E3L LDBAHSA DIA.DL QTY 23/4"24"3" E2 DH C13" E3LE1E1tE2E1 WP-D12X12.4 12"12"3/4"43/4"5"1 1/2" WP-D14X14.1 14"14"3/4"43/4"4"1 1/2" WP-E12X12.1 12"12"3/4"1 1/2"3"43/4"4" WP-E12X12.3 12"12"3/4"1 1/2"3"43/4"5" 10"WP-D10X10.1 10"3/4"43/4"4"1 1/2" W E E LEEtLW E E tEEWP-E14X14.1 14"14"3/4"1 1/2"3"43/4"4" WP-E14X14.2 14"14"3/4"1 1/2"3"43/4"5" WP-E8X8.2 8"8"1/2"1 1/2"3"45/8"5" WP-E10X10.2 10"10"3/4"1 1/2"3"43/4"5" WP-D12X12.3 12"12"3/4"43/4"6"1 1/2" WP-D14X14.2 14"14"3/4"43/4"5"1 1/2" WA-A3X3.1 3"3"1/4"1 1/2"35/8"4"10" 12"WP-B12X6.1 6 1/2"3/4"5"21 1/2" WA-B6X4.12 4"4"5/16"2"5/8"C2 4"5/8"2 2 t S1 2 1/2" 2 1/2" 3" 3 1/2" L 1'-0" 1'-0" 1'-0" 1'-0" S2 4" 4" 3" 4" S3 2" 2" 2" 2" EQ EQ Embed Angle -Type C (WA-C) L S1E E S3 S3 S2 ANGLE WA-C6X4.1 MARK WA-C5X5.1 ANCHORS (DBA) WA-C6X6.1 4" 5" b 6" 5" d 5/16" 3/8" t E 2" 2" 6"6"3/8"2" DIA.DL QTY 5/8" 3/4" 2'-0" 2'-0" 3/4"2'-0" DBA HSA LGTH 4" 5" 6" DIA. 5/8" 3/4" 3/4" ANCHORS (HSA) 2 2 2 QTY 2 2 2 WA-C6X4.2 4"6"5/16"2"5/8"1'-6"4"5/8"2 2 S1 2 1/2" 2 1/2" 3" 3 1/2" L 1'-0" 1'-0" 1'-0" 1'-0" S2 4" 4" 3" 4" S3 2" 2" 2" 2"EQ EQbdttDL1 1 8"WP-B8XS.2 S 1/2"3/4"5"21 1/2" Embed Plate -Type H (WP-H) W tWP-H12X16.1 WP-H12X18.1 PLATEMARK ANCHORS (HSA) W L t 12"16"1/2"1 1/2"EQEQEQE1 12"18"1/2"1 1/2" WP-H12X20.1 12"20"1/2"1 1/2" WP-H12X24.1 12"24"1/2"1 1/2" WP-H12X30.1 12"30"1/2"1 1/2" WP-H12X36.1 12"36"3/4"1 1/2" E1 DIA.LGTH QTY 61/2"4" ROWS 3 6 8 10 12 3 4 5 6 7 14 4" 4" 4" 4" 4" 1/2" 5/8" 5/8" 5/8" 3/4" E2E1E1ROWSL 3" 3" 3" 3" 3" 3" E2 WP-H12X22.1 12"22"1/2"1 1/2"844"5/8"3" WP-H12X40.1 12"40"3/4"1 1/2"7 144"3/4"3" WP-H12X48.1 12"48"3/4"1 1/2"8 164"3/4"3" WP-H12X33.1 12"33"1/2"1 1/2"1264"5/8"3" WP-H12X28.1 12"28"1/2"1 1/2"1054"5/8"3" WP-F12X48.1 12"48"3/4"1 1/2"8 164"3/4" WP-F12X40.1 12"40"3/4"1 1/2"7 144"3/4" WP-G12X30.1 12"33"1/2"1 1/2"1264"5/8" WP-G12X28.1 12"28"1/2"1 1/2"1054"5/8" WP-G12X22.1 12"22"1/2"1 1/2"844"5/8" WA-B6X6.16 WA-B6X6.18 WA-B6X6.20 WA-B6X6.22 WA-B6X6.24 WA-B6X6.28 WA-B6X6.30 WA-B6X6.33 WA-B6X6.36 WA-B6X6.40 WA-B6X6.48 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" 6"6"3/8"2"3/4"2'-0"6"3/4"2 23 1/2"1'-0"4"2" WP-H8X14.1 8"14"1/2"1 1/2"61/2"4"33" WP-E12X12.4 12"12"3/8"1 1/2"3"41/2"4" WP-D12X12.5 12"12"3/8"41/2"4"1 1/2" CC2.0 POST-INSTALLED ANCHORS IN CONCRETE: CC2.1 MATERIALS: 1. THE INSTALLATION OF POST-INSTALLED ANCHORS FOR MISSING OR MISPLACED CAST-IN PLACE ANCHORS SHALL BE APPROVED BY THE ENGINEER OF RECORD. 2. SUBMITTAL OF ALL PROPOSED PRODUCTS, WITH TECHNICAL DATA AND CURRENT ICC-ESR REPORTS IS REQUIRED FOR REVIEW AND APPROVAL BY ENGINEER OF RECORD. 3. MECHANICAL ANCHORS SHALL BE TESTED AND ASSESSED IN ACCORDANCE WITH THE MOST RECENT EDITION OF ACI 355.2 QUALIFICATION OF POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE (355.4) AND COMMENTARY AND ICC ES AC193 CONSIDERING CRACKED AND UNCRACKED CONCRETE. PRE-APPROVED MECHANICAL ANCHORS ARE AS FOLLOWS: A. HILTI: a. HILTI KWIK HUS EZ AND KWIK HUS EZ-I SCREW ANCHOR (ICC ESR-3027) b. HILTI HSL-3 EXPANSION ANCHOR (ICC ESR-1545) c. HILTI HDA UNDERCUT ANCHOR (ICC ESR-1546) d. HILTI KWIK BOLT TZ2 (ICC ESR-4266) e. HILTI KWIK BOLT 1 (IAPMO ER-678) B. SIMPSON: a. SIMPSON STONG-TIE TITEN HD AND TITEN-HD ROD HANGER (ICC ESR-2713) b. SIMPSON STRONG TIE STRONG-BOLT (ICC ESR-1771) c. SIMPSON STRONG-TIE STRONG-BOLT 2 (ICC ESR-3037) C. DEWALT: a. DEWALT SCREW-BOLT+ AND HANGERMATE+ (ICC ESR-3889) b. DEWALT POWER-STUD+ SD1 (ICC ESR-2818) c. DEWALT POWER-STUD+ SD2 (ICC ESR-2502) d. DEWALT POWER-BOLT+ (ICC ESR-3260) e. DEWALT CCU+ (ICC-ESR 4810) 4. ADHESIVE ANCHOR SYSTEMS SHALL BE TESTED AND ASSESSED IN ACCORDANCE WITH THE MOST RECENT EDITION OF ACI 355.4 QUALIFICATION OF POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE (355.4) AND COMMENTARY AND ICC ES AC308 CONSIDERING CRACKED AND UNCRACKED CONCRETE. PRE-APPROVED ADHESIVE ANCHORS ARE AS FOLLOWS: A. HILTI: a. HILTI HIT-HY 200 V3 WITH HIT-Z OR HAS THREADED RODS (ICC ESR-4866) b. HILTI RE 500 V3 (ICC ESR-3814) c. HILTI KWIK-X DUAL ACTION ANCHOR SYSTEM WITH KHC CAPSULE ADHESIVE AND KWIK-HUS EZ (ICC ESR-5065) B. SIMPSON: a. SIMPSON STONG-TIE SET-3G (ICC ESR-4057) C. DEWALT: a. DEWALT AC200+ (ICC ESR-4027) b. DEWALT PURE 110+ (ICC ESR-3298) c. DEWALT PURE 220+ (ICC ESR-5144) 5. ADHESIVE ANCHORS SELECTED FROM TEM 2 ABOVE SHALL BE SUPPLIED AS AN ENTIRE SYSTEM. THE SYSTEM SHALL INCLUDE, BUT IS NOT LIMITED TO, MANUFACTURERS PRINTED INSTALLATION INSTRUCTIONS (MPII) AS SUPPLIED WITH THE ADHESIVE, ADHESIVE CARTRIDGE, MIXING NOZZLE, EXTENSION TUBE, DISPENSER, AND ALL REQUIRED EQUIPMENT FOR PROPERLY CLEANING THE DRILLED HOLE. 6. ANCHOR DESIGN SHALL BE IN ACCORDANCE WITH CHAPTER 17 OF ACI 318-19. FOR ADHESIVE ANCHORS, THE FOLLOWING MINIMUM DESIGN VALUES FOR BOND STRESS WERE ASSUMED FOR THE DESIGN USING THE ABOVE ADHESIVE ANCHOR ASSEMBLIES FOR IMPACT-OR ROCKDRILLED HOLES: a. OUTDOOR/EXPOSED APPLICATION: Τcr = 200 PSI, Τuncr = 650 PSI b. INDOOR/DRY APPLICATION: Τcr = 300 PSI, Τuncr = 1000 PSI 7. ALL-THREADED ROD (EYEBOLTS, THREADED STUDS, INTERNAL THREADED PARTS) TO BE USED IN ADHESIVE ANCHOR ASSEMBLIES SHALL CONFORM TO ASTM A36, A193 (GRADE B7), F1554 OR OTHER APPROVED ANCHOR ASSEMBLY TYPES. STAINLESS STEEL ANCHOR RODS SHALL BE AISI TYPE 304 OR TYPE 316. THREADS SHALL BE UNC COARSE THREADS, UNLESS NOTED OTHERWISE. COMPATIBLE NUTS AND WASHERS SHALL BE FURNISHED WITH THE ALL-THREAD ROD AND CONSIDERED PART OF THE ASSEMBLY. WITH HOT-DIPPED GALVANIZED RODS, PROVIDE OVERSIZED TAPPED, HOT-DIPPED GALVANIZED NUTS. 8. NUTS, WASHERS, AND OTHER HARDWARE USED WITH AN ALL-THREADED BAR ADHESIVE ANCHOR SYSTEM OR WITH A MECHANICAL EXPANSION ANCHOR SHALL HAVE A MATERIAL OR AN ALLOY DESIGNATION THAT IS COMPATIBLE WITH THE ANCHOR ROD/ALLOY. GALVANIZED ASSEMBLIES SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A153 CLASS C. ELECTROPLATE GALVANIZING IS NOT ACCEPTABLE. DISSIMILAR METAL ASSEMBLIES SHALL BE SEPARATED BY NYLON, EPDM, OR OTHER APPROVED NON-METALLIC WASHERS. 9. REINFORCING BARS TO BE USED IN ADHESIVE ANCHOR ASSEMBLIES (E.G., AS ANCHOR REINFORCEMENT) OR AS POST-INSTALLED REINFORCING SHALL CONFORM TO ASTM A615 OR A706. CC2.2 GENERAL INSTALLATION GUIDELINES: 1. ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII) IN CONJUNCTION WITH EDGE DISTANCE, SPACING AND EMBEDMENT DEPTH AS INDICATED ON THE DRAWINGS. 2. DRILLED HOLES FOR POST-INSTALLED ANCHORS IN CONCRETE AND MASONRY SHALL BE COMPLETED PER OSHA 29 CFR 1926.1153 -RESPIRABLE CRYSTALLINE SILICA USING A TESTED SYSTEM SUCH AS DEWALT DUSTX+ EXTRACTOR AND DRILL BIT SYSTEM. 3. CONCRETE SHALL HAVE AN ABSOLUTE MINIMUM COMPRESSIVE STRENGTH (f’c) OF 2,500 PSI AT THE TIME OF ADHESIVE ANCHOR INSTALLATION. 4. CONCRETE AT TIME OF ADHESIVE ANCHOR INSTALLATION SHALL HAVE A MINIMUM AGE OF 21 DAYS. FOR INSTALLATION OF ADHESIVE ANCHORS IN CONCRETE HAVING AN AGE LESS THAN 21 DAYS, TESTS SHALL BE CONDUCTED TO VERIFY THE PERFORMANCE OF THE PRODUCT IN ACCORDANCE WITH ACI 355.4. 5. THE CONCRETE TEMPERATURE AT THE TIME OF ADHESIVE ANCHOR INSTALLATION SHALL BE AT LEAST 50°F UNLESS TESTING HAS BEEN CONDUCTED IN ACCORDANCE WITH RECOGNIZED CRITERIA TO VERIFY PERFORMANCE IN CONCRETE AT LOWER TEMPERATURES. 6. EMBEDMENT DEPTH AND MINIMUM ANCHOR PROJECTION OF THE ANCHOR ELEMENT FROM THE CONCRETE SURFACE SHALL BE AS SHOWN ON THE DRAWINGS OR DETAIL FOR THE PARTICULAR ANCHOR OR GROUP OF ANCHORS BEING INSTALLED. IN THE ABSENCE OF A SPECIFIC EMBEDMENT DEPTH OR ANCHOR PROJECTION , CONTRACTOR TO REQUEST SAID INFORMATION FROM THE ENGINEER PRIOR TO ANCHOR INSTALLATION. 7. ADHESIVE CARTRIDGES SHALL BE STORED UNDER CONDITIONS IN COMPLIANCE WITH MANUFACTURER RECOMMENDATIONS REGARDING TEMPERATURE, EXPOSURE TO SUNLIGHT, ETC. AND EVIDENCE OF COMPLIANCE SHALL BE MADE AVAILABLE UPON REQUEST. THE USE OF EXPIRED ADHESIVE, AS INDICATED BY THE EXPIRATION DATE ON THE CARTRIDGE, IS PROHIBITED. CC2.3 INSTALLATION: 1. ADHESIVE ANCHORS SHALL BE INSTALLED BY QUALIFIED PERSONNEL TRAINED TO INSTALL ADHESIVE ANCHORS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. BOTH POST-INSTALLED EXPANSION AND ADHESIVE ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS (MPII). 2. ADHESIVE ANCHORS WITH DIAMETER GREATER THAN 3/8-INCH INSTALLED IN ORIENTATIONS FROM HORIZONTAL TO VERTICAL SHALL EMPLOY A PISTON PLUG FOR THE ADHESIVE INJECTION. 3. INSTALLATION OF ADHESIVE ANCHORS IN ORIENTATIONS FROM HORIZONTAL TO VERTICAL TO SUPPORT SUSTAINED TENSION LOADS SHALL BE PERFORMED BY PERSONNEL CERTIFIED BY THE ACI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM OR EQUIVALENT. THESE ANCHORS ARE DESIGNATED WITH A (CERT) AFTER THE ANCHOR CALLOUT. NOTE: SOME DOWN-HOLE INSTALLATIONS SHOWN ON DRAWINGS SUPPORT SUSTAINED TENSION LOADS AND ARE SO DESIGNATED WITH A (CERT) AFTER THE ANCHOR CALLOUT. 4. THE INSTALLER’S QUALIFICATIONS SHALL BE SUBMITTED AND APPROVED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS) 5. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT REQUIRED TO INSTALL THE EXPANSION AND/OR ADHESIVE ANCHOR INCLUDING, BUT NOT LIMITED TO, DRILLS, SETTING TOOLS, CLEAN-OUT BRUSHES, BLOWOUT BULBS, OIL-FREE COMPRESSED AIR, VACUUMS, WRENCHES, ETC. 6. UNLESS OTHERWISE SPECIFIED, ANCHORS SHALL BE INSTALLED IN HOLES DRILLED WITH A ROTARY IMPACT HAMMER DRILL OR, WHERE NOT OTHERWISE PROSCRIBED, A ROCK DRILL. WHERE SPECIFIED AND WHERE PERMITTED BY THE MPII, HOLES MAY BE DRILLED WITH A DIAMOND CORE DRILL. IN ALL CASES, THE BIT DIAMETER SHALL BE IN ACCORDANCE WITH THE MPII. 7. ANCHOR HOLES SHALL BE THOROUGHLY CLEANED IN ACCORDANCE WITH THE PROCEDURES SPECIFIED IN THE MPII PRIOR TO ADHESIVE INJECTION. AT A MINIMUM, CLEAN WITH OIL-FREE AND MOISTURE-FREE COMPRESSED AIR USING A NOZZLE EXTENDED TO THE BOTTOM HOLE; SUPPLEMENT WITH A BRUSH OR OTHER TOOL CLEANING TO REMOVE ALL CONCRETE DUST AND LOOSE MATERIAL AND FOLLOW WITH A SECOND COMPRESSED AIR CLEANING. 8. DRILLED AND CLEANED ANCHOR HOLES SHALL BE PROTECTED FROM CONTAMINATION AND WATER (E.G. RAIN) UNTIL THE ADHESIVE IS INSTALLED. 9. A DRILLED ANCHOR HOLE SHALL BE RE-CLEANED JUST PRIOR TO ADHESIVE INJECTION IF, IN THE OPINION OF THE ENGINEER, INSPECTOR, OR OWNER'S REPRESENTATIVE, THE HOLE HAS BECOME CONTAMINATED AFTER INITIAL CLEANING. 10. ADHESIVE SHALL BE INJECTED IN ACCORDANCE WITH THE MPII USING EQUIPMENT AND PROCEDURES AS SPECIFIED THEREIN FOR THE SPECIFIC CONDITIONS ASSOCIATED WITH THE INJECTION. THIS SHOULD BE CLEARLY SPECIFIED IN THE MPII, IF NOT, ANOTHER PRODUCT SHOULD BE SPECIFIED. 11. ANCHOR ELEMENTS TO BE INSTALLED IN THE ADHESIVE SHALL BE CLEAN, OIL-FREE, AND FREE OF LOOSE RUST, PAINT, OR OTHER COATINGS. THREADS ON THE PROJECTING PORTION OF THE ANCHOR ELEMENT SHALL BE PROTECTED FROM ADHESIVE CONTAMINATION. 12. INSTALLED ADHESIVE ANCHORS SHALL BE SECURELY FIXED IN-PLACE TO PREVENT DISPLACEMENT WHILE THE ADHESIVE CURES. UNLESS SHOWN OTHERWISE ON THE DRAWINGS, ANCHORS SHALL BE INSTALLED PERPENDICULAR TO THE CONCRETE SURFACE. ANCHORS DISPLACED BEFORE FULL ADHESIVE CURE SHALL BE CONSIDERED DAMAGED AND REPLACED AT THE CONTRACTOR’S EXPENSE. 13. POST-INSTALLED REINFORCING BARS OR ALL-THREADED BARS SHALL NOT BE BENT AFTER BEING INSTALLED UNLESS SPECIFICALLY PERMITTED BY THE SEOR OR ON THE CONTRACT DOCUMENTS. CC2.4 FIELD QUALITY CONTROL: 1. THE IBC REQUIRES SPECIAL INSPECTION OF ALL POST-INSTALLED ANCHORS. ACI 318-19 SECTIONS 26.13.1.5 AND 26.13.1.6 REQUIRE THAT ALL INSPECTIONS OF MECHANICAL AND ADHESIVE ANCHORS, RESPECTIVELY, ARE PERFORMED BY A CERTIFIED FIELD INSPECTOR SPECIFICALLY APPROVED FOR THAT PURPOSE BY THE SEOR AND THE BUILDING OFFICIAL. CERTIFICATION IS ESTABLISHED THROUGH AN INDEPENDENT ASSESSMENT SUCH AS THE ACI POST-INSTALLED CONCRETE ANCHOR INSTALLATION INSPECTOR PROGRAM OR SIMILAR PROGRAM WITH EQUIVALENT REQUIREMENTS. ADHESIVE ANCHORS INSTALLED IN HORIZONTAL OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS SHALL BE CONTINUOUSLY INSPECTED DURING INSTALLATION BY A CERTIFIED INSPECTOR. ACI 318-19 26.13.3.2(E) REQUIRES THESE ANCHOR INSTALLATIONS TO BE INSPECTED BY A CERTIFIED SPECIAL INSPECTOR WHO IS CONTINUOUSLY PRESENT WHEN AND WHERE THE INSTALLATIONS ARE BEING PERFORMED. AS REQUIRED BY ACI 318-19, THE SPECIAL INSPECTOR SHALL SUBMIT A REPORT TO THE SEOR AND BUILDING OFFICIAL DESCRIBING THE WORK COVERED BY THE REPORT AND STATING THE WORK HAS BEEN PERFORMED, THE MATERIALS AND THE INSTALLATION PROCEDURES USED CONFORM TO THE APPROVED CONTRACT DOCUMENTS, AND THE WORK WAS INSTALLED ACCORDING TO THE MPII. 2. POST-INSTALLED EXPANSION AND ADHESIVE ANCHORS SHALL BE PROOF-LOADED AS REQUIRED BY THE CONTRACT DOCUMENTS. A MINIMUM 10 PERCENT OF EACH TYPE AND SIZE OF EACH TYPE OF SIZE OF ANCHOR ASSEMBLY SHALL BE PROOF LOADED IN TENSION BY AN INDEPENDENT TESTING LABORATORY UNLESS OTHERWISE INDICATED ON THE CONTRACT DOCUMENTS. a. PROOF LOADING SHALL BE CONDUCTED AS CONFINED TENSION TESTING FOR ADHESIVE ANCHORS USING A CENTER-HOLE CYLINDER. b. THE INDEPENDENT TESTING LABORATORY SHALL SUBMIT AN ANCHORAGE TESTING PLAN TO THE LICENSED DESIGN PROFESSIONAL TO ENSURE THE TESTING REQUIREMENTS ARE FULFILLED. 3. POST-INSTALLED EXPANSION AND ADHESIVE ANCHORS SHALL BE PROOF-LOADED TO LOAD LEVELS AS SHOWN ON THE CONTRACT DOCUMENTS. PROOF LOADING OF ADHESIVE ANCHORS SHALL BE PERFORMED AFTER A MINIMUM CURING PERIOD SPECIFIED BY THE MANUFACTURER. MINIMUM ADHESIVE ANCHOR PROOF LOADS SHALL BE 50 PERCENT OF EXPECTED ADHESIVE ULTIMATE BOND STRENGTH OR 80 PERCENT OF STEEL YIELD STRENGTH OF THE ANCHOR ROD, WHICHEVER IS LOWER. 4. ANCHORS SHALL HAVE NO VISIBLE INDICATIONS OF DISPLACEMENT OR DAMAGE DURING OR AFTER PROOF LOAD APPLICATION. CONCRETE CRACKING IN THE VICINITY OF THE ANCHOR AFTER LOADING SHALL BE CONSIDERED A FAILURE. 5. IF MORE THAN 10 PERCENT OF THE TESTED ANCHORS FAIL TO ACHIEVE THE SPECIFIED PROOF LOAD WITHIN THE LIMITS DEFINED ON THESE DRAWINGS, 100 PERCENT OF THE ANCHORS OF THE SAME DIAMETER AND TYPE AS THE FAILED ANCHOR SHALL BE PROOF TESTED, UNLESS OTHERWISE DIRECTED BY THE SEOR. Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:15:26 PMS0.111 General Notes - Reinforcement / Embeds Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 SCHEDULED VERITCAL REINFORCEMENT SPACING MASONRY INSPECTION AND CLEAN-OUT HOLE2'-8"10'-0" MAXAT CMU WALLS REQUIREING VEHICLE RESTAINT SPACING AS NOTED CENTERLINE CONTROL JOINT CIP CONCRETE COLUMN LINTEL SPAN (LS)LINTEL SPAN (LS)LINTEL SPAN (LS) 15 SCHEDULED VERTICAL WALL REINFORCEMENTREINFORCE AND GROUT INTERSECTING CELL W/ SCHEDULED REINFORCEMENT SCHEDULED VERTICALWALL REINFORCEMENTPREFABRICATED T-SHAPED LAP SECTION SCHEDULED VERTICAL WALL REINFORCEMENT SCHEDULED VERTICALWALL REINFORCEMENTLAP SPLICECONT BOND BEAM REINFORCEMENT SCHEDULED VERTICAL WALL REINFORCEMENT SCHEDULED VERTICALWALL REINFORCEMENTLAP SPLICECONT BOND BEAM REINFORCEMENT SCHEDULED VERTICAL WALL REINFORCEMENT REINFORCE AND GROUT INTERSECTING CELL W/ SCHEDULED REINFORCEMENT SCHEDULED VERTICALWALL REINFORCEMENT1'-4" LAPPREFABRICATED L-SHAPED LAP SECTIONTYPICAL BUILDING PAPER SCHEDULED VERTICAL WALL REINFORCEMENT SCHEDULED VERTICAL WALL REINFORCEMENT GROUT FILLED PREFORMED GASKET SCHEDULED VERTICAL WALL REINFORCEMENT SCHEDULED VERTICAL WALL REINFORCEMENT S0.131 .1_______ S0.131 .2_______ AT GRADEAT GRADE S0.130 .5_______ S0.130 .6_______ S0.130 .6_______ S0.130 .4_______ S0.130 .3_______ S0.130 .2_______ S0.130 .1_______ AT ELEVATED SLAB CMU WALL DIAGRAM CONCRETE MASONRY UNIT (CMU) NOTES: 1. CONCRETE MASONRY WALL MATERIALS, CONSTRUCTION, AND INSPECTION SHALL CONFORM TO THE REQUIREMENTS PRESCRIBED IN THE AMERICAN CONCRETE INSTITUTE "BUILDING CODE REQUIREMENTS OF MASONRY STRUCTURES" (ACI 530/ASCE 5/TMS 402) AND THE "SPECIFICATION FOR MASONRY STRUCTURES" (ACI 530.1/ASCE 6/TMS 602), AS WELL AS REQUIREMENTS PRESCRIBED BY LOCAL BUILDING CODE. 2. REFER TO ARCHITECTURAL DRAWINGS AND DETAILS FOR DIMENSIONAL CONTROL OF MASONRY CONSTRUCTION. 3. CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT CONFORMING TO ASTM C-90 AND HAVE MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1,900 PSI UNLESS NOTED OTHERWISE. 4. MASONRY MORTAR SHALL CONFORM TO ASTM C-270, TYPE M OR S. TYPE M MORTAR SHALL HAVE MINIMUM 28-DAY STRENGTH = 2,500 PSI. TYPE S MORTAR SHALL HAVE MINIMUM 28-DAY STRENGTH = 1,800 PSI. RECOMMENDED MORTAR TYPE BY USE: BUILDING SEGMENT MORTAR TYPE EXTERIOR, ABOVE GRADE: • LOAD BEARING S or M • NON-LOAD BEARING & PARAPET S EXTERIOR, AT OR BELOW GRADE S or M INTERIOR: • LOAD BEARING S or M • NON-LOAD BEARING S 10. PROVIDE MINIMUM ONE VERTICAL BAR EACH SIDE OF OPENINGS UP TO 4’-0 WIDE. PROVIDE MINIMUM TWO VERTICAL BARS EACH SIDE OF OPENING GREATER THAN 4’-0. PROVIDE MINIMUM ONE VERTICAL BAR AT WALL CORNERS, INTERSECTIONS AND EACH SIDE OF CONTROL JOINTS. EDGE AND INTERSECTION REINFORCING SHALL MATCH TYPICAL WALL REINFORCING SIZE AND EXTEND FULL HEIGHT OF WALL. 11. PROVIDE DOWELS INTO SUPPORTING STRUCTURE (FOOTINGS, BEAMS, SLABS) TO MATCH SIZE AND SPACING OF WALL VERTICAL REINFORCEMENT. REFER TO TYPICAL DETAILS FOR ADDITIONAL INFORMATION. 12. PROVIDE MINIMUM REBAR LAP LENGTHS AS NOTED BELOW: • #4: 20” • #5: 28” • #6: 45” • #7: 62” a. LAPS SHALL OCCUR MINIMUM 24”CLEAR OF INTERSECTING BOND BEAMS. 13. PROVIDE CONTINUOUS 9 GAUGE HOT DIPPED GALVANIZED LADDER TYPE HORIZONTAL JOINT REINFORCEMENT AT 16”O.C.. PROVIDE PREFABRICATED L-SHAPED AND T-SHAPED LAP SECTIONS AT WALL INTERSECTIONS. FULLY EMBED IN MORTAR BED AND EXTEND ENTIRE LENGTH OF BED JOINT. 14. PROVIDE CONTINUOUS HORIZONTAL BOND BEAM AT FLOOR LEVELS, ROOF LEVEL, TOP OF PARAPET, AND AS SHOWN IN TYPICAL DETAILS. WHERE WALL HEIGHT EXCEEDS 12’-0, PROVIDE CONTINUOUS HORIZONTAL BOND BEAM AT 10’-0 O.C. MAX. UTILIZE BOND BEAM BLOCKS OR KNOCK OUT BLOCKS AND REINFORCE WITH (2) #5 CONTINUOUS UNLESS NOTED OTHERWISE. KNOCK OUT BLOCKS IN WALLS SHALL HAVE METAL LATH, MESH, OR WIRE SCREEN IN BED JOINTS TO PREVENT FILLING OF UNGROUTED CELLS. USE OF ROOFING FELT OR MATERIALS THAT BREAK BOND BETWEEN UNITS AND MORTAR ARE NOT ACCEPTABLE. 15. U.N.O. ON ARCHITECTURAL NOTES AND SPECIFICATIONS, CONTROL JOINT SPACING SHALL NOT EXCEED THE SMALLER OF 2.5 TIMES WALL HEIGHT OR 25'-0". REINFORCE CELLS ADJACENT TO CONTROL JOINT WITH CONTINUOUS VERTICAL REINFORCEMENT AND GROUT SOLID. CONTROL JOINT SHALL NOT BE PLACED CLOSER THAN 2’-0”FROM THE VERTICAL FACE OF ANY OPENING. HORIZONTAL BOND BEAM REINFORCEMENT SHALL BE CONTINUOUS THROUGH JOINTS U.N.O.. 16. CONCRETE MASONRY WALLS SHOWN IN THE DRAWINGS ARE DETAILED TO RESIST CODE REQUIRED LOADS AFTER REACHING THEIR FINAL BUILT CONFIGURATION ASSUMING TOP, BOTTOM, AND SIDE CONNECTIONS/BRACING AS SHOWN. THE CONTRACTOR SHALL PROVIDE ENGINEERED BRACING FOR MASONRY WALLS DURING CONSTRUCTION, WHICH SHALL NOT BE REMOVED UNTIL WALLS ARE CONNECTED TO SUPPORTING ELEMENTS AT ALL POINTS AS NOTED IN THE CONTRACT DOCUMENTS. 17. SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH “SPECIAL INSPECTIONS”SECTION OF THESE DRAWINGS. 5. REINFORCED CELLS AND BOND BEAMS SHALL BE GROUTED SOLID. GROUT SHALL CONFORM TO ASTM C-476 AND HAVE MINIMUM 28-DAY STRENGTH = 2,500 PSI. USE COURSE GROUT FOR SPACES 4”OR LARGER, AND USE FINE GROUT FOR SPACES SMALLER THAN 4”. GROUT SHALL BE CONSOLIDATED BY THOROUGH RODDING OR VIBRATING ALL CELLS DURING PLACEMENT. AIR ENTRAINMENT IS NOT PERMITTED. 6. GROUT SOLID ALL CELLS BELOW GRADE. 7. CONCRETE MASONRY SHALL HAVE A MINIMUM PRISM ASSEMBLY STRENGTH OF 1,900 PSI UNLESS NOTED OTHERWISE. 8. CMU SHALL BE CONSTRUCTED IN A RUNNING BOND CONFIGURATION WITH LOW-LIFT GROUT PLACEMENT. 9. REBAR SHALL CONFORM TO ASTM A-615, GRADE 60 UNLESS NOTED OTHERWISE. UTILIZE BAR SUPPORTS AND POSITIONERS AS REQUIRED TO ENSURE PROPER PLACEMENT WITHIN WALLS AS NOTED IN THE DRAWINGS. TYPE A TYPE B TYPE C CMU LINTEL SCHEDULE SPAN (LS)TYPE ALS ≤5'-0" LS > 5'-0" ≤8'-0" LS > 8'-0" ≤12'-0" B CMU SIZE 6" 6" 8" -12" LS > 5'-0" ≤8'-0"8" -12" 8" -12" LS ≤5'-0"A B C CONT BOTT REINF (1) #5 (1) #5 (2) #5 (2) #5 (2) #5 CONT TOP REINF - CONT MID- DEPTH REINF - STIRRUP REINF (2) #5 (2) #5 -- -- -- #2 AT 12" O.C. #2 AT 12" O.C. #2 AT 12" O.C. 6"8-12"6"8-12"8-12" SOLID BOTTOM U-BLOCK CONT BOTTOM REINF U-BAR STIRRUP REINF SOLID BOTTOM U-BLOCK CONT BOTTOM REINF CLOSED STIRRUP REINF CONT TOP REINF CONT MID-DEPTH REINF SOLID BOTTOM U-BLOCK CONT BOTTOM REINF MIN. BEARING 8" 8" 8" 8" 16" SCHEDULED REINF SCHEDULED REINF SCHEDULED REINF - - Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:15:33 PMS0.130 CMU General Notes / Typical Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"3 CMU Intersection - Plan 3/4" = 1'-0"4 CMU Bond Beam Intersection - Plan 3/4" = 1'-0"2 CMU Bond Beam Corner - Plan 3/4" = 1'-0"1 CMU Corner - Plan 3/4" = 1'-0"6 Opening in CMU Wall 3/4" = 1'-0"5 CMU Control Joint CMU SCHEDULE -INTERIOR WALLS HEIGHT (H) H≤10'-0"8" CMU SIZE H>10'-0" ≤15'-0" H>15'-0" ≤20'-0" 8" CMU 8" CMU REINFORCEMENT CMU SCHEDULE -EXTERIOR WALLS HEIGHT (H) 8" CMU SIZE 8" CMU 10" CMU REINFORCEMENT #5 AT 32" O.C. #4 AT 16" O.C. #6 AT 24" O.C. H>20'-0" ≤25'-0"10" CMU H>25'-0" ≤30'-0"12" CMU #5 AT 32" O.C. #5 AT 32" O.C. #5 AT 24" O.C. #5 AT 16" O.C. #5 AT 16" O.C. H≤10'-0" H>10'-0" ≤15'-0" H>15'-0" ≤20'-0" No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 LAP SPLICE = SEE CMUGNERAL NOTESLAP SPLICE = SEE CMUGNERAL NOTESLAP SPLICE = SEE CMUGNERAL NOTESSLAB ON GRADE - SEE PLAN CMU WALL -SEE SCHEDULE FOR REINFORCEMENT (2) #5 CONT. DOWELS TO MATCH SCHEDULED VERTICAL REINFORCEMENT SIZE AND SPACING - ALTERNATE DIRECTION OF HOOKS 1' - 6"1' - 0"EQ EQ CMU LINTEL -SEE SCHEDULE CONT. BOND BEAM W/ (2) #5 CONT. CMU WALL -SEE SCHEDULE FOR REINFORCEMENT OPENING(2) #5 CONT. SCHEDULED CMU WALL / REINF 6"1' - 6"H ≤ 1'-0"SLAB STEP (H)1' - 0"SLAB STEP (H ≤1'-0") "Z" BAR W/ STD. 90⌀ HOOKS TO MATCH SLAB REINF SIZE AND SPACING SLAB ON GRADE -SEE PLAN DOWELS TO MATCH SCHEDULED VERTICAL REINFORCEMENT SIZE AND SPACING - ALTERNATE DIRECTION OF HOOKS SLAB ON GRADE -SEE PLAN (2) #5 CONT.6"1' - 6"> 1'-0" H ≤ 2'-6"SLAB STEP (H)1' - 0"#4 AT 12" O.C. HORIZ (2 BARS MIN) SLAB STEP (> 1'-0" H ≤2'-6") CMU WALL -SEE SCHEDULE FOR REINFORCEMENT DOWELS TO MATCH SCHEDULED VERTICAL REINFORCEMENT SIZE AND SPACING - ALTERNATE DIRECTION OF HOOKS "Z" BAR W/ STD. 90⌀ HOOKS TO MATCH SLAB REINF SIZE AND SPACING Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:15:34 PMS0.131 CMU Typical Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 CMU Bearing at Grade 3/4" = 1'-0"2 Opening in CMU Wall No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 Scale Date Drawn By Checked By Project Number 3/18/2026 9:15:41 PMS0.200 3D Views - Bldg#1 - T01 Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NW Corner - Bldg #1 - T01 3 3D View - SE Corner - Bldg #1 - T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - NW Corner - Bldg #1 - T01 3 3D View - SE Corner - Bldg #1 - T01 Scale Date Drawn By Checked By Project Number 3/18/2026 9:15:48 PMS0.201 3D Views - Bldg#1 - T01 Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NE Corner - Bldg #1 - T01 2 3D View - SW Corner - Bldg #1 - T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - NE Corner - Bldg #1 - T01 2 3D View - SW Corner - Bldg #1 - T01 Scale Date Drawn By Checked By Project Number 3/18/2026 9:15:54 PMS0.202 3D Views - Bldg#3 - T01 Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NW Corner - Bldg T02 2 3D View - SE Corner - Bldg T02 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - NW Corner - Bldg T02 2 3D View - SE Corner - Bldg T02 Scale Date Drawn By Checked By Project Number 3/18/2026 9:15:59 PMS0.203 3D Views - Bldg#3 - T01 Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NE Corner - Bldg T02 2 3D View - SW Corner - Bldg T02 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - NE Corner - Bldg T02 2 3D View - SW Corner - Bldg T02 Scale Date Drawn By Checked By Project Number 3/18/2026 9:16:05 PMS0.204 3D Views - Bldg T02 Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NW Corner - Bldg #3 - T01 2 3D View - SE Corner - Bldg #3 - T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - NW Corner - Bldg #3 - T01 2 3D View - SE Corner - Bldg #3 - T01 Scale Date Drawn By Checked By Project Number 3/18/2026 9:16:14 PMS0.205 3D Views - Bldg T02 Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NE Corner - Bldg #3 - T01 2 3D View - SW Corner - Bldg #3 - T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 Scale Date Drawn By Checked By Project Number 3/18/2026 9:16:17 PMS0.206 3D Views - Garages Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - SE Corner - Garages 2 3D View - NW Corner - Garages No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - SE Corner - Garages 2 3D View - NW Corner - Garages Scale Date Drawn By Checked By Project Number 3/18/2026 9:16:23 PMS0.207 3D Views - Garages Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - SW Corner - Garages 2 3D View - NE Corner - Garages No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1 3D View - SW Corner - Garages 2 3D View - NE Corner - Garages Scale Date Drawn By Checked By Project Number 3/18/2026 9:10:21 PMS0.208 3D Views - Clubhouse Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - NE Corner 2 3D View - NW Corner No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25Issue for Conformance 11/21/25 100% IFC 03/18/26 Scale Date Drawn By Checked By Project Number 3/18/2026 9:10:24 PMS0.209 3D Views - Clubhouse Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 1 3D View - SE Corner 2 3D View - SW Corner No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25Issue for Conformance 11/21/25 100% IFC 03/18/26 S0.300 2 . WALL PLATE SPLICE S0.300 1 . LEDGER PLUMBING RISER TYPICAL DROP HEADER DEEP HEADER AT CUT TOP PLATES S0.300 5 .CAVITYFLOORTYPICAL DROP HEADER OPENINGS 8'-0" AND LESS OPENINGS GREATER THAN 8'-0" AND LESS THAN 12'-0" PROVIDE (2) 2X SILL PLATES PROVIDE (1) 2X SILL PLATES FLUSH BEAM 2' - 0" MAX SCHEDULED STUDS PROVIDE ONE ADDITIONAL STUD TO EXISTING STUD SCHEDULED WALL HEADER -SEE PLAN AND SCHEDULE (2) 2x TOP PLATES (2) 10d COMMON (3" X 0.148") TOENAIL 16d COMMON (3 1/2" X 0.162") AT 12" O.C. STAGGERED TRIMMER (U.N.O. ON PLAN): • (1) 2X TRIMMER AT OPENINGS 6'-0" OR LESS • (2) 2X TRIMMERS AT OPENINGS 6'-0" OR GREATER WINDOW SILL (WHERE OCCURS): • (1) 2X SILL AT OPENINGS 4'-0" OR LESS • (2) 2X SILL AT OPEINGS GREATER THAN 4'-0" SCHEDULED 2X WALL STUDS SIMPSON A34 (#9) CLIP AT OPENINGS GREATER THAN 8'-0" CRIPPLE STUDS TO MATCH SCHEDULED WALL STUDS KNEE WALL STUDS (WHERE OCCURS) TO MATCH SCHEDULED WALL STUDS KINGPOST (U.N.O. ON PLAN): • (1) 2X KINGPOST AT OPENINGS 6'-0" OR LESS • (2) 2X KINGPOST AT OPENINGS 6'-0" OR GREATER • AT SHEARWALL LOCATIONS SEE SHEARWALL END-POST DETAIL PROVIDE (2) 16d COMMON (3 1/2" X 0.162"⌀) NAILS AT HEADERS 5 1/2" DEEP. PROVIDE (2) ADDITIONAL NAILS FOR EACH 2" OF ADDITIONAL HEADER DEPTH NOTE: SEE FASTENING SCHEDULE FOR ALL NAILING NOT NOTED (1) 2x SILL PLATE POST -SEE PLAN / SCHEDULE SIMPSON LPCZ POST CAP UNO ON PLAN BEAM -SEE PLAN / SCHEDULE SIMPSON CMST14 STRAP X 5'-0" MIN. CENTERED AT BEAM SPLICE OVER C.L. OF POST SPLICE TO OCCUR DIRECTLY OVER C.L. OF POST POST -SEE PLAN / SCHEDULE BEAM -SEE PLAN / SCHEDULE SIMPSON EPCZ POST CAP UNO ON PLAN WD1.0 WOOD CONSTRUCTION GENERAL NOTES: A. ALL WOOD HORIZONTAL AND VERTICAL FRAMING, FURRING, ANCHORAGE AND CONNECTIONS NOT EXPLICITLY SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE PER MINIMUM REQUIRED BY THE LOCALLY ADOPTED BUILDING CODE. B. PROVIDE STRUCTURAL LUMBER AND ENGINEERED WOOD OF THE FOLLOWING MINIMUM GRADES, SPECIES AND MINIMUM ALLOWABLE STRESSES UNLESS NOTED OTHERWISE ON PLAN: a. STUDS SEE STUD SCHEDULE b. PLATES STRUCT. GRADE DFL OR SYP NO. 3 c. JOISTS STRUCT. GRADE DFL OR SYP NO. 2 d. BEAMS UP TO 4”THK DFL OR SYP NO. 2 e. POSTS DFL OR SYP NO. 2 f. BLOCKING DFL OR SYP NO. 3 g. GLULAM MEMBERS 24F-V4 (DF) OR V3 (SYP) FOR SIMPLY SUPPORTED BEAMS 24F-V8 (DF) OR V5 (SYP) FOR CANTILEVERED AND CONTINUOUS BEAMS a. PSL BEAMS MIN. Fb = 2,900 PSI, Fv = 285 PSI, E = 2,000 KSI b. PSL POSTS MIN. Fb = 2,400 PSI, E = 1,800 KSI c. LSL MEMBERS MIN. Fb = 1,700 PSI, Fv = 400 PSI, E = 1,300 KSI ADDITIONAL NOTES: a. ALL LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED TESTING AGENCY. b. LVL BEAMS/POSTS WITH EQUAL OR GREATER SIZE THAN PSL BEAMS/POSTS AND MEET PSL MINIMUM STRENGTH AND STIFFNESS REQUIREMENTS MAY BE SUBSTITUTED FOR PSL BEAMS/POSTS. c. FLOOR BRIDGING TO BE PER LOCALLY ADOPTED BUILDING CODE. d. PROVIDE LUMBER WITH 19% MAXIMUM MOISTURE CONTENT. MOISTURE MAY BE MEASURED JUST PRIOR TO PLACEMENT. C. WOOD STRUCTURAL PANEL FLOOR SHEATHING: 23/32”THICK TOUNGE AND GROOVE (TG) DOC PS-1 (PLY) OR PS-2 (OSB) EXPOSURE 1 WITH A PANEL INDEX OF 48/24 AND STAMPED WITH APA GRADE TRADEMARK. ALL WOOD STRUCTURAL FLOOR PANELS SHALL BE NAILED TO SUPPORTS WITH 0.148”⌀NAILS X 2.25”MIN. LONG WITH NAIL SPACING OF 6”OC AT PANEL EDGES / BOUNDARIES AND 12”OC AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON THE STRUCTURAL DRAWINGS. D. WOOD STRUCTURAL PANEL ROOF SHEATHING: DOC PS-1 (PLY) OR DOC PS-2 (OSB) EXPOSURE 1 STAMPED WITH APA GRADE TRADEMARK WITH THE FOLLOWING MINIMUM THICKNESS, PANEL INDEX AND FASTENING REQUIREMENTS: a. ROOF SLOPE OF 3:12 OR GREATER: 15/32”THICKNESS WITH A PANEL INDEX 32/16. FASTEN TO SUPPORTS WITH 0.131”⌀NAILS x 2.5”LONG WITH NAIL SPACING PER STANDARD FASTENING SCHEDULE OR AS INDICATED ON ROOF DIAPHRAGM BLOCKING AND NAILING PLANS, WHICHEVER IS SMALLER. b. ROOF SLOPE LESS THAN 3:12 TO FLAT: 19/32”THICKNESS WITH A PANEL INDEX OF 40/20. FASTEN TO SUPPORTS WITH 0.148”⌀NAILS x 2.25”LONG WITH NAIL SPACING PER STANDARD FASTENING SCHEDULE OR AS INDICATED ON ROOF DIAPHRAGM BLOCKING AND NAILING PLANS, WHICHEVER IS SMALLER. E. WOOD STRUCTURAL PANEL SHEAR WALL SHEATHING: EXPOSURE 1. SEE SHEAR WALL SCHEDULE FOR OTHER INFORMATION INCLUDING MINIMUM THICKNESS, GRADE AND FASTENING REQUIREMENTS. F. ALL LUMBER IN CONTACT WITH CONCRETE, CMU OR EXPOSED TO WEATHER SHALL BE PRESERVATIVE TREATED. G. PROVIDE FIRE RETARDANT TREATED (FRT) WOOD WHERE INDICATED ON THE STRUCTURAL OR ARCHITECTURAL DRAWINGS. H. UNLESS NOTED OTHERWISE, ALL NAILS ARE COMMON NAILS WITH DIMENSONAL PROPERTIES COMPLYING WITH AFPA NDS TABLE L4 AND ASTM F1667. INSTALL ALL NAILS PER FASTENING SCHEDULE OR AS INDICATED ON THE STRUCTURAL DRAWINGS. I. ALL FASTENERS AND HARDWARE CONNECTORS, INCLUDING NUTS AND WASHERS INSTALLED IN OR ATTACHED TO FRT WOOD USED IN EXTERIOR APPLICATIONS OR WET OR DAMP LOCATIONS SHALL BE HOT DIP GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS OTHER THAN NAILS, TIMBER RIVETS, WOOD LAG SCREWS AND LAG SCREWS SHALL BE PERMITTED TO BE OF MECHANICALY DEPOSITED ZINC COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B695, CLASS 55 MIN. J. ALL FASTENERS AND HARDWARE CONNECTORS, INCLUDING NUTS AND WASHERS INSTALLED IN OR ATTACHED TO FRT AND PRESERVATIVE TREATED WOOD USED IN INTERIOR APPLICATIONS SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. IN INSTANCES WHERE SUCH RECOMMENDATIONS DO NOT EXIST, CONFORM TO THE REQUIREMENTS FOR EXTERIOR APPLICATIONS. K. ALL FASTENERS AND HARDWARE CONNECTORS, INCLUDING NUTS AND WASHERS INSTALLED IN OR ATTACHED TO PRESERVATIVE TREATED WOOD SHALL BE HOT DIP GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS OTHER THAN NAILS, TIMBER RIVETS, WOOD LAG SCREWS AND LAG SCREWS SHALL BE PERMITTED TO BE OF MECHANICALY DEPOSITED ZINC COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B695, CLASS 55 MIN. CONNECTORS THAT ARE USED IN EXTERIOR APPLICATIONS AND IN CONTACT WITH PRESERVATIVE TREATED WOOD SHALL HAVE COATING TYPES AND WEIGHTS IN ACCORDANCE WITH THE TREATED WOOD OR CONNECTOR MANUFACTURER RECOMMENDATIONS. IN THE ABSENCE OF MANUFACTURER RECOMMENDATIONS, PROVIDE MINIMUM OF ASTM A653, TYPE G185 ZINC COATED GALVANIZED STEEL OR EQUIVALENT.EXCEPTION: PLAIN CARBON STEEL FASTENERS, INCUDING NUTS AND WASHERS IN SBX / DOT AND ZINC BORATE PRESERVATIVE TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT MAY BE USED. L. FASTENING SCHEDULE SHALL BE IN CONFORMANCE WITH IBC / CBC TABLE 2304.10.1. WD2.0 WOOD FRAMING GENERAL NOTES: A. FLOOR AND ROOF FRAMING LAYOUTS ARE PROVIDED TO ILLUSTRATE DESIGN INTENT AND CONDITIONS OF CONSTRUCTION AND DO NOT NECESSARILY INDICATE SPECIFIC QUANTITIES OF MATERIALS NOR COMPONENTS REQUIRED FOR CONSTRUCTION. CONSTRUCTION BRACING SHALL BE PROVIDED BY THE CONTRACTOR TO MAINTAIN THE BUILDING PLUMB AND TRUE WITH BRACING TO REMAIN IN PLACE UNTIL THE SPECIFIED SHEAR WALLS ARE FULLY INSTALLED. B. BEARING WALL ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES SHALL MEET THE FOLLOWING MINIMUMS AT EACH BEARING END / POINT: C. THE CENTERLINE OF THE GIRDER TRUSS OR SOLID WOOD BEAM SHALL BE THE CENTERLINE OF THE SUPPORTING BEARING WALL STUD PACK OR POST. D. THE SUPPORTING BEARING WALL STUD PACK OR POST SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN T SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR / ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. E. PROVIDE 2x4 (MIN.) FLATWISE @ 24”OC MAX. BETWEEN FLOOR FRAMING UNDER PARTITIONS ABOVE WHICH ARE PARALLEL TO FRAMING BUT NOT DIRECTLY OVER THE FRAMING AND FASTEN TO FLOOR FRAMING WITH (2) 0.148” DIA X 3”LONG TOENAILS EA. END UNO ON PLAN OR DETAILS. F. STRUCTURAL MEMBERS SHALL NOT BE CUT, TRIMMED OR BORED FOR PIPES OR OTHER BUILDING COMPONENTS UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAW INGS. NOTCHING AND BORING OF STUDS AND TOP/BOTTOM PLATES SHALL CONFORM TO SECTIONS 2308.5.9 AND 2308.5.10 OF THE IBC/CBC.WHERE TOP/BOTTOM PLATES ARE CUT FOR PIPES, PROVIDE 1.5 INCH WIDE X 16 GA STEEL STRAP TIE FASTENED TO EACH PLATE ACROSS AND TO EACH SIDE OF THE CUT-OUT FASTENED ACROSS EACH PLATE ON EACH SIDE OF THE CUT OUT WITH NO LESS THAN (6) 16d NAILS EACH SIDE PER CHAPTER 23 OF THE IBC/CBC. G. ALL JOIST / FLUSH BEAMS SHALL BE SUPPORTED BY A HANGER WITH AN APPROVAL FROM AN AGENCY DEEMED ACCEPTABLE TO THE LOCAL BUILDING OFFICIAL. H. PROVIDE CONTINUOUS END TO END STRONGBACKS ON ALL JOIST SPANS OVER 7’-6”AND (2) STRONGBACKS AT ALL JOIST SPANS OVER 15’-0”. STRONGBACKS SHALL BE INSTALLED PERPENDICULAR TO AND NAILED DIRECTLY TO JOIST FRAMING. I. AT CONVENTIONAL FRAMING, PROVIDE THE FOLLOWING WHERE APPLICABLE: a. COLLAR TIES OF 1X6 BOARDS INSTALLED AT THE UPPER THIRD OF THE RIDGE BEAM DEPTH SPACED 4’-0”OC MAX; b. SOLID 2X, METAL CROSS OR WOOD CROSS BRIDGING AT 8’-0”OC MAX FOR JOIST SPANS OVER 10’-0”; c. PURLINS OF SAME SIZE AS RAFTERS AT ALL RAFTER SPANS OVER 7’-6”FOR 2X6, 10’-0”FOR 2X8, 12’-6”FOR 2X10 AND 15’-0”FOR 2X12 J. PROVIDE DOUBLE JOISTS AT LOCATIONS WHERE NON LOAD BEARING PARTITIONS ARE PLACED PARALLEL TO JOIST SPAN. IF WALL ABOVE IS A PLUMBING WALL, APPROPRIATELY SPACE DOUBLE JOISTS TO ALLOW PLUMBING LINES TO STACK. K. EXTERIOR WALLS AT VAULTED CEILINGS SHALL BE BALLOON FRAMED. L. WHERE BUILT-UP OVERFRAMING IS USED TO CREATE SLOPES AT EXPOSED ROOF DECKS AND SKYDECKS, OVERFRAMING PERPENDICULAR TO FLOOR FRAMING SHALL BE RIPPED 2X MEMBERS AT 24”OC MAX. WITH PERPENDICULAR BLOCKING AT 48”OC MAX. TYPICAL UNO ON PLAN OR DETAILS. M. 2X4 CHIMNEY CONSTRUCTION SHALL BE SHEATHED WITH 15/32”WOOD STRUCTURAL PANEL. FRAMING MEMBER MINIMUM STUDS/STUDPACKS (UNLESS NOTED OTHERWISE ON PLAN) h 4'-0" OR LESS 4'-1" TO 8'-0" MINIMUM WIDTH 8'-1" TO 12"-0" INTERIOR AND EXTERIOR LOAD BEARING HEADER (DROP BEAM)SEE NOTE a a. PROVIDE SAME NUMBER OF TRIMMER STUDS AS NUMBER OF BEAM PLIES PLUS (1) KINGSTUD (PROVIDE MINIMUM OF 3 TOTAL STUDS) b. PROVIDE (1) MORE TRIMMER STUDS AS NUMBER OF BEAM PLIES PLUS (2) KINGSTUDS (PROVIDE MINIMUM OF 4 TOTAL STUDS) c. PROVIDE (1) MORE STUD THAN NUMBER OF PLIES OF BEAM d. PROVIDE (2) MORE STUDS THAN NUMBER OF PLIES OF BEAM e. PROVIDE (1)2x6 TRIMMER AND (1)2x6 KINGSTUD f. PROVIDE (2)2x6 TRIMMERS AND (2)2x6 KINGSTUDS g. PROVIDE (1) MORE STUD THAN NUMBER OF TRUSS PLIES (PROVIDE MINIMUM 4 STUDS) h. FOR SOLID FRAMING MEMBERS, "NUMBER OF PLIES OF BEAM" EQUALS 2, 3, AND 4 PLIES FOR NOMINAL BEAM WIDTHS OF 4 INCHES, 6 INCHES, AND 8 INCHES, RESPECTIVELY SEE NOTE c SEE NOTE e SEE NOTE a SEE NOTE d SEE NOTE e SEE NOTE b SEE NOTE d SEE NOTE f INTERIOR AND EXTERIOR FLUSH BEAM EXTERIOR NON-LOAD BEARING HEADER (DROP BEAM) LOCATION / MEMBER GIRDER TRUSS SEE NOTE g WD3.0 WOOD CONNECTOR GENERAL NOTES: A. ALL SPECIFIED FASTENERS MUST BE INSTALLED ACCORDING TO MANUFACTURER INSTRUCTIONS. INCORRECT FASTENER QUANTITY, SIZE, PLACEMENT, TYPE, MATERIAL, OR FINISH MAY CAUSE THE CONNECTION TO FAIL. PRIOR TO USING A PARTICULAR FASTENER, REFER TO MANUFACTURER SPECIFICATIONS. B. LARGER DIAMETER FASTENERS MAY BE SUBSTITUTED FOR SMALLER DIAMETER FASTENERS IN CONNECTORS PROVIDED THE LARGER FASTENER DOES NOT CAUSE SPLITTING IN THE WOOD MEMBER AND THE CONNECTOR HOLES ARE NOT ENLARGED. C. FILL ALL FASTENER HOLES AS SPECIFIED IN THE INSTALLATION INSTRUCTIONS FOR THAT PRODUCT. REFER TO MANUFACTURER FOR THE REQUIREMENTS OF VARIOUS SHAPED FASTENER HOLES. D. DO NOT OVERDRIVE NAILS. OVERDRIVEN NAILS REDUCE SHEAR CAPACITY. E. PRODUCTS SHALL BE INSTALLED FOR THE USE SPECIFIED. USE ONLY THE MATERIALS SPECIFIED IN THE INSTALLATION INSTRUCTIONS. SUBSTITUTION OF OR FAILURE TO USE SPECIFIED MATERIALS MAY CAUSE THE CONNECTION TO FAIL. DO NOT ALTER INSTALLATION PROCEDURES FROM THOSE SET FORTH IN MANUFACTURER SPECIFICATIONS. F. DO NOT ADD FASTENER HOLES OR OTHERWISE MODIFY CONNECTOR PRODUCTS. THE PERFORMANCE OF MODIFIED PRODUCTS MAY BE SUBSTANTIALLY WEAKENED. BE ADVISED MANUFACTURER WILL NOT WARRANT OR GUARANTEE THE PERFORMANCE OF SUCH MODIFIED PRODUCTS. G. THE PROPER USE OF CERTAIN PRODUCTS REQUIRES THAT THE PRODUCT BE BENT. FOR THOSE PRODUCTS, INSTALLERS MUST NOT BEND THE PRODUCT MORE THAN ONE TIME (ONE FULL CYCLE). H. BOLT HOLES SHALL BE AT LEAST A MINIMUM OF 1/32" AND NO MORE THAN A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER (PER THE 2015 / 2018 NDS, SECTION 12.1.3.2 AND AISI S100, TABLE E3A IF APPLICABLE). I. INSTALL ALL SPECIFIED FASTENERS BEFORE LOADING THE CONNECTION. J. SOME HARDENED FASTENERS MAY HAVE PREMATURE FAILURE IF EXPOSED TO MOISTURE. THESE FASTENERS ARE RECOMMENDED TO BE USED IN DRY INTERIOR APPLICATIONS. K. USE PROPER SAFETY EQUIPMENT. L. WELDING GALVANIZED STEEL MAY PRODUCE HARMFUL FUMES; FOLLOW PROPER WELDING PROCEDURES AND SAFETY PRECAUTIONS. WELDING SHOULD BE IN ACCORDANCE WITH A.W.S. (AMERICAN WELDING SOCIETY) STANDARDS. UNLESS OTHERWISE NOTED, CONNECTORS CANNOT BE WELDED. M. PNEUMATIC OR POWER-ACTUATED FASTENERS MAY DEFLECT AND INJURE THE OPERATOR OR OTHERS. PNEUMATIC NAIL TOOLS MAY BE USED TO INSTALL CONNECTORS, PROVIDED THE CORRECT QUANTITY AND TYPE OF NAILS (LENGTH AND DIAMETER) ARE PROPERLY INSTALLED IN THE NAIL HOLES. CONNECTORS WITH TOOL EMBOSSMENTS OR TOOLS WITH NAIL HOLE-LOCATING MECHANISMS SHOULD BE USED. FOLLOW THE MANUFACTURER’S INSTRUCTIONS AND USE THE APPROPRIATE SAFETY EQUIPMENT. POWER-ACTUATED FASTENERS SHOULD NOT BE USED TO INSTALL CONNECTORS, UNLESS SPECIFICALLY NOTED BY MANUFACTURER. N. JOIST SHALL BEAR COMPLETELY ON THE CONNECTOR SEAT, AND THE GAP BETWEEN THE JOIST END AND THE HEADER SHALL NOT EXCEED 1/8" PER ICC-ES AC13, ASTM D1761 AND ASTM D7147 TEST STANDARDS (UNLESS SPECIFICALLY NOTED OTHERWISE). O. FASTENERS ARE PERMITTED TO BE INSTALLED THROUGH METAL TRUSS PLATES WHEN APPROVED BY THE TRUSS DESIGNER IN ACCORDANCE WITH ANSI/TPI 1-2014, SECTION 7.5.3.4 AND 8.9.2. DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF SINGLE-PLY TRUSSES WHICH COULD FORCE THE PLATE OFF THE TRUSS. P. NUTS SHALL BE INSTALLED SUCH THAT THE END OF THE THREADED ROD OR BOLT IS AT LEAST FLUSH WITH THE TOP OF THE NUT. Q. WHEN INSTALLING HURRICANE TIES ON THE INSIDE OF THE WALL, SPECIAL CONSIDERATIONS MUST BE TAKEN TO PREVENT CONDENSATION ON THE INSIDE OF THE COMPLETED STRUCTURE IN COLD CLIMATES. R. UNLESS OTHERWISE NOTED, CONNECTORS HAVE BEEN DESIGNED TO BE INSTALLED AT THE TIME THE FRAMING MEMBERS ARE INSTALLED. WD4.0 PRE-MANUFACTURED WOOD TRUSS SPECIFICATIONS: 1. DESIGN A. DESIGN AND DETAILING OF PRE-MANUFACTURED WOOD TRUSSES ARE DELEGATED TO THE GENERAL CONTRACTOR IN ACCORDANCE WITH SECTION "GN1.5 -DEFERRED SUBMITTALS". B. TRUSS MANUFACTURER SHALL REFER TO ARCHITECTURAL DRAWINGS FOR TRUSS END BEARING TYPE AND/OR END SUPPORT CONDITION. ALL TRUSSES SHALL BE DESIGNED TO MEET ARCHITECTURAL INTENT AT EACH LEVEL AND EACH END SUPPORT CONDITION AS REQUIRED. C. DESIGN TRUSSES FOR LOADING CRITERIA PROVIDED IN SECTIONS GN1.1 THROUGH GN1.4 OF THE GENERAL NOTES AS A MINIMUM. a. INCREASE DEAD LOAD AS NEEDED TO ACCOUNT FOR TRUSS SELF WEIGHT. b. DESIGN TRUSS BOTTOM CHORD FOR 5 PSF DEAD LOAD AS A MINIMUM. DESIGN TRUSS TOP CHORD FOR 20 PSF DEAD LOAD AS A MINIMUM. c. INCREASE DEAD LOAD AS NEEDED TO ACCOUNT FOR LIGHTWEIGHT / GYPCRETE TOPPING AND FLOOR FINISHES WHERE APPLICABLE. d. REFER TO PLUMBING DRAWINGS AND INCREASE LOADING AS NEEDED TO ACCOUNT FOR SPRINKLER AND WATER SUPPLY LINES D. TRUSS MANUFACTURER SHALL FURNISH TRUSS DESIGN DRAWINGS PREPARED IN ACCORDANCE WITH ALL APPLICABLE LEGAL REQUIREMENTS. E. THE TRUSS MANUFACTURER SHALL FURNISH A TRUSS PLACEMENT DIAGRAM WHICH SHALL PROVIDE AT A MINIMUM THE LOCATION ASSUMED FOR EACH TRUSS BASED ON THE TRUSS MANUFACTURER'S INTERPRETATION OF THE CONSTRUCTION DOCUMENTS. F. THE TRUSS MANUFACTURER SHALL SUBMIT THE TRUSS SUBMITTAL PACKAGE TO THE ARCHITECT, SEOR, AND GENERAL CONTRACTOR FOR REVIEW AND APPROVAL PRIOR TO THE MANUFACTURING OF THE TRUSSES. G. TRUSS DESIGN DOCUMENTS SUBMITTED FOR REVIEW SHALL BE SIGNED AND SEALED BY AN ENGINEER LICENSED IN THE JURISDICTION OF THE PROJECT AND INCLUDE THE FOLLOWING ITEMS: a. BUILDING CODE USED FOR DESIGN CALCULATIONS CORRESPONDING TO THE DESIGN SHOWN. b. SLOPE OR DEPTH, SPAN, AND SPACING. c. LOCATION OF ALL JOINTS AND SUPPORT LOCATIONS. d. NUMBER OF PLIES IF GREATER THAN ONE. e. REQUIRED BEARING WIDTHS. f. DESIGN LOADS AS APPLICABLE, INCLUDING (REFER TO GENERAL NOTES FOR APPLICABLE DESIGN LOADS. TRUSS MANUF TO PROVIDE A MINIMUM OF 5PSF BOTTOM CHORD DEAD LOAD. TRUSS MANUFACTURER): • TOP CHORD LIVE LOAD (FOR ROOF TRUSSES THIS SHALL BE THE CONTROLLING CASE OF LIVE, RAIN OR SNOW LOAD); XX • TOP CHORD DEAD LOAD; XX • BOTTOM CHORD LIVE LOAD; XX • BOTTOM CHORD DEAD LOAD; XX • ADDITIONAL LOADS AND LOCATIONS. (INCLUDING ROOF LEVEL MECHANICAL LOADS AS APPLICABLE) • ENVIRONMENTAL LOAD DESIGN CRITERIA (WIND SPEED, SNOW, SEISMIC, AND ALL APPLICABLE FACTORS AS REQUIRED TO CALCULATE THE TRUSS LOADS); AND • OTHER LATERAL LOADS, INCLUDING DRAG STRUT LOADS. g. ADJUSTMENTS TO WOOD MEMBER AND METAL CONNECTOR PLATE DESIGN VALUES FOR CONDITIONS OF USE. h. MAXIMUM REACTION FORCE AND DIRECTION, INCLUDING MAXIMUM UPLIFT REACTION FORCES WHERE APPLICABLE. i. METAL CONNECTOR PLATE TYPE, MANUFACTURER, SIZE, THICKNESS OR GAUGE, AND THE DIMENSIONED LOCATION OF EACH METAL CONNECTOR PLATE EXCEPT WHERE SYMMETRICALLY LOCATED RELATIVE TO THE JOINT INTERFACE. j. SIZE, SPECIES, AND GRADE FOR EACH WOOD MEMBER; k. TRUSS-TO-TRUSS CONNECTION AND TRUSS FIELD ASSEMBLY REQUIREMENTS. l. CALCULATED SPAN TO DEFLECTION RATIO AND/OR MAXIMUM VERTICAL AND HORIZONTAL DEFLECTION FOR LIVE AND FOR LIVE PLUS DEAD LOAD AND KCR (CREEP FACTOR) AS APPLICABLE. m. MAXIMUM AXIAL COMPRESSION AND TENSION FORCES IN THE TRUSS MEMBERS. n. FABRICATION TOLERANCE PER ANSI/TPI 1. o. REQUIRED PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT LOCATION. p. TRUSS DESIGNER WD4.0 PREMANUFACTURED WOOD TRUSS SPECIFICATIONS (CONT): H. PROVIDE DOUBLE TOP CHORD FOR ALL APPLICABLE TRUSSES AS NOTED ON WOOD DIAPHRAGM BLOCKING/STRAPPING PLANS. I. TRUSSES SHALL BE DESIGNED FOR WIND UPLIFT WHERE APPLICABLE AND MECHANICALLY FASTENED AT EACH BEARING LOCATION WITH APPROPRIATE UPLIFT CONNECTORS. SEE SECTION "GN3.0 -COMPONENT AND CLADDING WIND PRESSURE" FOR LOADING AND TYPICAL FRAMING DETAILS FOR LOAD PATH INTENT. J. LIMIT DEFLECTIONS FOR FLOOR TRUSSES TO L/480 FOR LIVE LOADS AND L/360 FOR TOTAL LOADS, BUT NOT TO EXCEED 1 INCH. LIMIT DEFLECTIONS FOR ROOF TRUSSES TO L/240 FOR LIVE LOADS AND L/180 FOR TOTAL LOADS, BUT NOT TO EXCEED 1.25 INCH. K. PROVIDE TRUSS BLOCKS OR ALIGHT DRAG TRUSSES ABOVE SHEARWALLS AS REQUIRED. SEE TYPICAL DETAILS. DESIGN FOR FORCES SHOWN ON PLANS OR SCHEDULED SHEARWALL CAPACITY. L. TRUSS BLOCKS. TRUSS SUPPLIER TO PROVIDE TRUSS BLOCKS AT INTERMEDIATE TRUSS BEARING POINTS (ALL TRUSS TYPES) AND AT ENDS (BOTTOM CHORD BEARING TRUSSES ONLY). TRUSSES MAY BE SITE BUILT OR PREFABRICATED. ALL TRUSS BLOCKS SHALL BE DESIGNED TO RESIST A MINIMUM ALLOWABLE LATERAL LOAD OF 1.5 KIPS AT THE ROOF LEVEL AND 2.5 KIPS AT ALL FLOORS, TYPICAL. IN ADDITION, THE TOP CHORD OF THE TRUSS BLOCK MUST BE VERTICAL WHEN INSTALLED UNDER LOAD BEARING WALLS. 2. MATERIALS A. LUMBER a. LUMBER USED SHALL BE IDENTIFIED BY GRADE MARK OF A LUMBER INSPECTION BUREAU OR AGENCY APPROVED BY THE AMERICAN LUMBER STANDARDS COMMITTEE, AND SHALL BE THE SIZE, SPECIES, AND GRADE AS SHOWN ON THE TRUSS DESIGN DRAWINGS, OR EQUIVALENT AS APPROVED BY THE TRUSS DESIGNER. b. ADJUSTMENT OF VALUE FOR DURATION OF LOAD OR CONDITIONS OF USE SHALL BE IN ACCORDANCE WITH ANSI/TPI 1. c. FIRE RETARDANT TREATED (FRT) LUMBER, WHERE APPLICABLE, SHALL MEET THE SPECIFICATIONS OF THE FIRE RETARDANT CHEMICAL MANUFACTURER, THE TRUSS DESIGN AND ANSI/TPI 1 AND SHALL BE RE- DRIED AFTER TREATMENT TO 19 PERCENT MAXIMUM MOISTURE CONTENT AT TEMPERATURES NOT TO EXCEED 160°F (71°C) IN ACCORDANCE WITH AWPA STANDARDS C20. FRT LUMBER DESIGN VALUES SHALL BE DEVELOPED FROM APPROVED TEST METHODS AND PROCEDURES THAT CONSIDER POTENTIAL STRENGTH-REDUCTION CHARACTERISTICS, INCLUDING THE EFFECTS OF ELEVATED TEMPERATURE AND MOISTURE. DESIGN VALUES SHALL BE APPROVED BY THE AUTHORITIES HAVING JURISDICTION. LUMBER TREATER SHALL SUPPLY CERTIFICATE OF COMPLIANCE. B. METAL CONNECTOR PLATES a. METAL CONNECTOR PLATES SHALL BE MANUFACTURED BY A SBCA MEMBER PLATE MANUFACTURER AND SHALL BE OF GALVANIZED STEEL, ALUMINUM-ZINC ALLOY COATED STEEL OR STAINLESS STEEL CONFORMING TO THE REQUIREMENTS OF ANSI/TPI 1. MINIMUM THICKNESS IN INCHES (OR MM FOR METRIC UNITS), INCLUDING BOTH UNCOATED AND COATED THICKNESSES, IF GALVANIZED AND ALUMINUM-ZINC ALLOY COATED, SHALL BE SPECIFIED FOR EACH TYPE OF METAL CONNECTOR PLATE. WORKING STRESSES IN STEEL ARE TO BE APPLIED TO EFFECTIVENESS RATIOS FOR PLATES AS DETERMINED BY TEST AND IN ACCORDANCE WITH ANSI/TPI 1. b. IN HIGHLY CORROSIVE ENVIRONMENTS, SPECIAL APPLIED COATINGS OR STAINLESS STEEL MAY BE REQUIRED, AS SPECIFIED IN THE CONTRACT DOCUMENTS. 3. MANUFACTURING A. TRUSSES SHALL BE MANUFACTURED TO MEET THE QUALITY REQUIREMENTS OF ANSI/TPI 1 AND IN ACCORDANCE WITH THE INFORMATION PROVIDED IN THE FINAL APPROVED TRUSS DESIGN DRAWINGS. 4. HANDLING, INSTALLING, AND BRACING A. TRUSSES SHALL BE HANDLED DURING MANUFACTURING, DELIVERY AND BY THE CONTRACTOR AT THE JOB SITE SO AS NOT TO BE SUBJECTED TO EXCESSIVE BENDING. B. TRUSSES SHALL BE UNLOADED IN A MANNER SO AS TO MINIMIZE LATERAL STRAIN. TRUSSES SHALL BE PROTECTED FROM DAMAGE THAT MIGHT RESULT FROM ON-SITE ACTIVITIES AND ENVIRONMENTAL CONDITIONS. TRUSSES SHALL BE HANDLED IN SUCH A WAY SO AS TO PREVENT TOPPLING WHEN BANDING IS REMOVED. WD4.0 PREMANUFACTURED WOOD TRUSS SPECIFICATIONS (CONT): C. CONTRACTOR SHALL BE RESPONSIBLE FOR THE HANDLING, INSTALLATION, AND TEMPORARY RESTRAINT/BRACING OF THE TRUSSES IN A GOOD WORKMANLIKE MANNER AND IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN SBCA/TPI’S BUILDING COMPONENT SAFETY INFORMATION (BCSI): GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING, RESTRAINING & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES. D. APPARENT DAMAGE TO TRUSSES, IF ANY, SHALL BE REPORTED TO TRUSS MANUFACTURER PRIOR TO ERECTION. E. TRUSSES SHALL BE SET AND SECURED LEVEL AND PLUMB, AND IN CORRECT LOCATION. EACH TRUSS SHALL BE HELD IN CORRECT ALIGNMENT UNTIL SPECIFIED PERMANENT RESTRAINT AND BRACING IS INSTALLED. F. CUTTING AND ALTERING OF TRUSSES IS NOT PERMITTED. IF ANY TRUSS SHOULD BECOME BROKEN, DAMAGED, OR ALTERED, WRITTEN CONCURRENCE AND APPROVAL BY A REGISTERED DESIGN PROFESSIONAL IS REQUIRED. G. CONCENTRATED LOADS SHALL NOT BE PLACED ON TOP OF TRUSSES UNTIL ALL SPECIFIED RESTRAINT AND BRACING HAS BEEN INSTALLED AND STRUCTURAL SHEATHING IS PERMANENTLY NAILED IN PLACE. SPECIFICALLY AVOID STACKING FULL BUNDLES OF CONSTRUCTION MATERIALS OR OTHER CONCENTRATED LOADS ON TOP OF TRUSSES. H. THE TRUSS SUBMITTAL PACKAGE AND ANY SUPPLEMENTARY INFORMATION PROVIDED BY THE TRUSS MANUFACTURER SHALL BE PROVIDED BY THE CONTRACTOR TO THE INDIVIDUAL OR ORGANIZATION RESPONSIBLE FOR THE INSTALLATION OF THE TRUSSES. I. TRUSSES SHALL BE PERMANENTLY RESTRAINED AND BRACED IN A MANNER CONSISTENT WITH GOOD BUILDING PRACTICES AS OUTLINED IN BCSI AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. TRUSSES SHALL FURTHERMORE BE ANCHORED OR RESTRAINED TO PREVENT OUT-OF-PLANE MOVEMENT SO AS TO KEEP ALL TRUSS MEMBERS FROM SIMULTANEOUSLY BUCKLING TOGETHER IN THE SAME DIRECTION. SUCH PERMANENT LATERAL RESTRAINT SHALL BE ACCOMPLISHED BY: (A) ANCHORAGE TO SOLID END WALLS; (B) PERMANENT DIAGONAL BRACING IN THE PLANE OF THE WEB MEMBERS; OR (C) OTHER SUITABLE MEANS. J. MATERIALS USED IN TEMPORARY AND PERMANENT RESTRAINT AND BRACING SHALL BE FURNISHED BY CONTRACTOR. 5. MISCELLANEOUS A. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED OR OTHERWISE ALTERED IN ANY WAY WITHOUT WRITTEN APPROVAL FROM THE TRUSS ENGINEER. WHERE FIELD REPAIRS OF DAMAGED TRUSSES ARE REQUIRED, THE TRUSS ENGINEER SHALL SUBMIT A SIGNED/SEALED TRUSS REPAIR PROFILE TO THE GENERAL CONTRACTOR PRIOR TO REPAIR INSTALLATION. THE GENERAL CONTRACTOR SHALL SUBMIT ALL SIGNED/SEALED TRUSS REPAIRS TO THE STRUCTURAL ENGINEER OF RECORD ON A MONTHLY BASIS FOR PROJECT RECORD (INFORMATIONAL PURPOSES ONLY). B. TRUSS MANUFACTURER SHALL COORDINATE TRUSS LAYOUT WITH MECH/PLUMBING DRAWINGS TO ALLOW ALL PIPES AND DUCTS ADEQUATE SPACE FOR PROPER INSTALLATION. THE MANUFACTURER SHALL COORDINATE THE WEB MEMBER CONFIGURATION WITH THE MECHANICAL DRAWINGS AND ARCHITECTURAL DRAWINGS SUCH THAT ADEQUATE OPENING IS PROVIDED FOR ANY MECHANICAL UNITS AND DUCTS AND ACCESS CATWALKS. HARD DUCT LOCATIONS, AS INDICATED ON THE MECHANICAL DRAWINGS, SHALL BE SHOWN ON THE SUBMITTED TRUSS LAYOUT SHOP DRAWINGS FOR DESIGN TEAM REVIEW. C. TRUSSES SHALL BE SPACED AS SHOWN ON THE PLANS; LESSER SPACING MAY BE USED IF REQUIRED BY THE TRUSS DESIGNER. HOWEVER, THE USE OF LESS TRUSS SPACING THAN INDICATED IN THE DESIGN DOCUMENTS SHALL NOT BE JUSTIFICATION FOR AN OWNER CHANGE ORDER. IT IS THE RESPONSIBILITY OF THE FRAMER AND THE TRUSS DESIGNER TO REVIEW PROJECT LOADING, REQUIRED SPANS AND TRUSS CONFIGURATIONS DURING THE BIDDING PROCESS. D. IN ADDITION TO THE TYPICAL TRUSS LOADING PROVIDED HEREIN, TRUSS MANUFACTURER TO COORDINATE WITH MEP DRAWINGS FOR ADDITIONAL LOADS DUE TO WATER-FILLED PIPE SUPPORTS AND SPRINKLER PIPE SUPPORTS. TRUSS DESIGNER SHALL APPLY A MINIMUM 250 POUND CONCENTRATED LIVE LOAD TO ANY SINGLE FIRE SPRINKLER SUPPORT POINT TO ACCOMODATE INSTALLATION PERSONNEL PER NFPA 13 (NATIONAL FIRE PROTECTION ASSOCIATION) STANDARD FOR INSTALLATION. THE 250 POUND CONCENTRATED LOAD IS NOT REQUIRED TO BE APPLIED CONCURRENTLY TO OTHER CONCENTRATED SUPPORT POINTS AND NON-CURRENT WITH OTHER LIVE LOADS SUCH AS ROOF LIVE, FLOOR LIVE, SNOW, WIND, ETC. HEADER -SEE PLAN AND SCHEDULE (2) 2x TOP PLATES TRIMMER: • (1) 2X TRIMMER AT OPENINGS 6'-0" OR LESS • (2) 2X TRIMMERS AT OPENINGS 6'-0" OR GREATERSCHEDULED 2X WALL STUDS FOR EACH TOP PLATE CUT, PROVIDE A SIMPSON CS16 STRAP W/ MINIMU (13) 0.131"⌀X 2 1/2" LONG NAILS INTO HEADER AND TOP PLATE AT EA END KINGPOST (U.N.O. ON PLAN): • (1) 2X KINGPOST AT OPENINGS 6'-0" OR LESS • (2) 2X KINGPOST AT OPENINGS 6'-0" OR GREATER • AT SHEARWALL LOCATIONS SEE SHEARWALL END-POST DETAIL PROVIDE (2) 16d COMMON (3 1/2" X 0.162"⌀) NAILS AT HEADERS 5 1/2" DEEP. PROVIDE (2) ADDITIONAL NAILS FOR EACH 2" OF ADDITIONAL HEADER DEPTH NOTE: SEE FASTENING SCHEDULE FOR ALL NAILING NOT NOTED FLOOR SHEATHING FLOOR TRUSS, TYP. SEE FRAMING NOTES MECH. BAY COORD. LOCATION, WIDTH & WEIGHT W/ MECH. 2' - 8" MAX. 2x6 FLAT LADDER FRAMING (T&B) @ 24" O.C. FASTEN EA. END W/ (2) 0.148"x3" TOENAILS EA. END OR SIMPSON Z2 CLIP Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:16:27 PMS0.300 General Notes - Wood Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"2 Wall Plate Splice Detail 3/4" = 1'-0"1 Framed Opening in Stud Wall 3/4" = 1'-0"3 Wood Beam to Post Interior Connection 3/4" = 1'-0"4 Wood Beam to Post End Connection 3/4" = 1'-0"5 Deep Header at Cut Top Plates 3/4" = 1'-0"6 Section at Floor Truss Ladder Framing for Mech. No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 CANTILEVER TRUSS SPAN TRUSS SPAN PARALLELTRUSS SPAN WD5.0 CONTINUOUS ROD TIE-DOWN SYSTEM (HOLDOWN) GENERAL NOTES: A. THE CONTINUOUS ROD TIEDOWN SYSTEM SPECIFIED AND SCHEDULED FOR THIS PROJECT IS BASED ON THE SIMPSON STRONG-TIE STRONG-ROD ANCHOR TIEDOWN SYSTEM (ATS) OR APPROVED EQUAL FOR SHEAR WALL OVERTURNING RESTRAINT. B. THE TOTAL VERTICAL DISPLACEMENT BETWEEN RESTRAINT LOCATIONS, INCLUDING STEEL ROD ELONGATION AND SHRINKAGE COMPENSATING DEVICE DEFLECTION, IS CALCULATED TO BE LESS THAN 0.20 INCHES USING ALLOWABLE STRESS DESIGN (ASD). C. THE ATS IS BE RESTRAINED BY A BEARING PLATE AND TAKE-UP DEVICE ASSEMBLY AT EACH STORY OF THE MULTI-STORY SHEAR WALLS. D. DO NOT WELD PRODUCTS UNLESS THE ATS INSTALLATION DETAILS SPECIFICALLY IDENTIFY A PRODUCT AS ACCEPTABLE FOR WELDING. RODS, NUTS, AND COUPLER NUTS SHALL NOT BE WELDED. E. IN THE EVENT OF A DISCREPANCY BETWEEN THESE STRUCTURAL DRAWINGS AND THE ATS INSTALLATION DETAILS, THESE STRUCTURAL DRAWINGS SHALL GOVERN. F. THE STRUCTURAL DRAWINGS ARE SPECIFIC TO THE SIMPSON STRONG-TIE STRONG-ROD ANCHOR TIEDOWN SYSTEM (ATS) AND ARE NOT APPLICABLE TO OTHER MANUFACTURERS’CONTINUOUS ROD TIEDOWN SYSTEMS. PROPOSED SUBSTITUTIONS OF OTHER MANUFACTURERS’CONTINUOUS ROD TIEDOWN SYSTEMS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL. SUBMITTAL SHALL INCLUDE EVALUATION REPORTS INDICATING COMPLIANCE WITH GOVERNING BUILDING CODES AND TEST DATA DEEMED ACCEPTABLE TO THE BUILDING OFFICIAL. IN ADDITION, SUBMITTAL SHALL INCLUDE INSTALLATION DETAILS AND INSTRUCTIONS, CALCULATIONS IN ACCORDANCE WITH THE GOVERNING BUILDING CODES, AND CERTIFICATION BY THE MANUFACTURER OF COMPLIANCE WITH THESE ATS SPECIFICATIONS AND THE STRUCTURAL DRAWINGS. G. ATS RUN START / TERMINATIONS SHALL BE AS SET FORTH ON THESE STRUCTURAL DRAWINGS. ALTERNATE RUN START / TERMINATIONS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO CONCRETE PLACEMENT. SUBMITTAL SHALL INCLUDE CALCULATIONS IN COMPLIANCE WITH THE GOVERNING BUILDING CODE, INCLUDING CONCRETE ANCHORAGE IN ACCORDANCE WITH ACI 318 PROVISIONS FOR STRENGTH DESIGN AND CONVERSION TO ASD LOAD LEVELS. H. THE ATS IS DESIGNED TO BE INSTALLED FLOOR BY FLOOR AS THE STRUCTURE IS BUILT. INSTALLATION IN THIS MANNER, WITH SHEAR WALLS, WILL PROVIDE A LATERAL-FORCE-RESISTING SYSTEM DURING CONSTRUCTION. THE DESIGN AND EXPENSE OF ALTERNATIVE METHODS OF TEMPORARY LATERAL-FORCE- RESISTING SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR. I. A PRE-CONSTRUCTION MEETING IS RECOMMENDED WITH SIMPSON STRONG-TIE PRIOR TO PLACEMENT OF THE CONCRETE. THE PURPOSE OF THIS MEETING IS TO ASSIST IN VERIFYING QUANTITIES AND UNDERSTANDING THE INSTALLATION PROCESS. TO COORDINATE THIS MEETING, CALL SIMPSON STRONG-TIE AT (800) 999-5099. J. RTUD AND ATUD BEARING PLATES SHALL BE PROVIDED BY SIMPSON STRONG-TIE BASED ON SCHEDULED WALL WIDTH AND MAXIMUM TAKE UP DEVICE TENSION CAPACITY AT EACH LEVEL. WD7.0 WOOD SHRINKAGE REQUIREMENTS: THE FOLLOWING ARE REQUIRED (GENERAL CONTRACTOR TO COORDINATE WITH ALL TRADES AS REQUIRED): A. THE VERITCAL WOOD FRAMING SHOWN IN THE DRAWINGS IS ANTICIPATED TO SHRINK OVER TIME. LIKEWISE, EXTERIOR MASONRY FACADE (WHEN APPLICABLE) MAY EXPAND DUE TO SEASONAL TEMPERATURE EFFECTS. THESE DIFFERENTIAL MOVEMENTS MUST BE ACCOUNTED FOR TO PREVENT DAMAGE TO RIGID FINISHES AND NON-STRUCTURAL ITEMS. B. DETAILING AND CONSTRUCTION OF MECHANICAL SYSTEMS AND ARCHITECTURAL FINISHES (INCLUDING BUT NOT LIMITED TO MASONRY FACADE, STONE FACADE, VENEERS, DRYWALL SHEATHING, PLYWOOD SHEATHING, WINDOWS, DOOR THRESHHOLDS, OTHER BRITTLE FINISHES, AND MECHANICAL/ELECTRICAL. PLUMBING LINES AND ROOF DRAINAGE SYSTEMS) SHALL ACCOUNT FOR ESTIMATED DIFFERENTIAL MOVEMENT (WOOD SHRINKAGE + BRICK EXPANSION) AS INDICATED IN THE FOLLOWING TABLES WHERE '1ST FLOOR' REPRESENTS LOWEST WOOD FRAMED LEVEL: ESTIMATED MAXIMUM WOOD SHRINKAGE [DOWNWARD] 5TH FLOOR 1 1/4" 1" 3/4" 1/2" 1/4" 4TH FLOOR 3RD FLOOR 2ND FLOOR 1ST FLOOR C. MASONRY LATERAL TIES SHALL ALLOW FOR FULL FREE DIFFERENTIAL MOVEMENTS DEFINED ABOVE. D. ROUGH OPENINGS IN WOOD FRAMINGS SHALL BE OVERSIZED VERTICALLY TO PROVIDE A MINIMUM 1" ADDITIONAL CLEARANCE BETWEEN TOP OF NON-STRUCTURAL PASS THROUGH ELEMENT AND TOP OF HOLE. ESTIMATED MAXIMUM BRICK EXPANSION [UPWARD] (WHEN APPLICABLE) 5TH FLOOR 5/8" 1/2" 3/8" 1/4" 1/8" 4TH FLOOR 3RD FLOOR 2ND FLOOR 1ST FLOOR WD8.0 WOOD FASTENING SCHEDULE: DESCRIPTION OF BUILDING ELEMENTS 1. BLOCKING BETWEEN CEILING JOIST, RAFTERS, OR TRUSSES TO TOP PLATE OF OTHER FRAMING BELOW • BLOCKING BETWEEN RAFTERS OR TRUSS NOT AT THE WALL TOP PLATE, TO RAFTER OR TRUSS • FLAT BLOCKING TO TRUSS AND WEB FILLER 2. CEILING JOIST TO TOP PLATE 3. CEILING JOIST ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS (NO THRUST) (3) 8d COMMON (2 1/2" X 0.131"); OR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS; OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN (2) 8d COMMON (2 1/2" X 0.131"); OR (2) 3" X 0.131" NAILS; OR (3) 3" 14 GAGE STAPLES (2) 16d COMMON (3 1/2" X 0.162"); OR (2) 3" X 0.131" NAILS: OR (2) 3" 14 GAGE STAPLES 16d COMMON (3 1/2" X 0.162") @ 6"o.c. 3" X 0.131" NAILS @ 6"o.c. 3" 14 GAGE STAPLES @ 6"o.c. (3) 8d COMMON (2 1/2" X 0.131"); OR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS: OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN EACH JOIST, TOENAIL PER TABLE FACE NAIL FACE NAIL END NAIL EACH END, TOENAIL EACH END, TOENAIL FACE NAIL TOENAILC TOENAIL ROOF WALL 24" O.C. FACE NAIL 16" O.C. FACE NAIL 16" O.C. EACH EDGE, FACE NAIL TOENAIL 16" O.C. FACE NAIL 12" O.C. FACE NAIL 16" O.C. FACE NAIL 12" O.C. FACE NAIL EACH SIDE OF END JOIST, FACE NAIL (MINIMUM 24" LAP SPLICE LENGTH EACH SIDE OF END JOIST) 16" O.C. FACE NAIL TOENAIL END NAIL FACE NAIL FACE NAIL FACE NAIL FACE NAIL WD8.0 WOOD FASTENING SCHEDULE (CONT): (2) 8d COMMON (2 1/2" X 0.131"); OR (2) 10d BOX (3" X 0.128") EACH BEARING, FACE NAIL 10d BOX (3" X 0.128"); OR 3" X 0.131" NAILS: OR 3" 14 GAGE STAPLES, 7/16" CROWN 32" O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES FACE NAIL FACE NAIL ENDS AND AT EACH SPLICE, FACE NAIL EACH JOIST OR RAFTER, FACE NAIL END NAIL EACH END, TOENAIL FLOOR 6" NUMBER AND TYPE OF FASTENERS SPACING AND LOCATION NUMBER AND TYPE OF FASTENERS SPACING AND LOCATION (2) 16d COMMON (3 1/2" X 0.162") 20d COMMON (4" X 0.192") (2) 16d COMMON (3 1/2" X 0.162") 24" O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES AND: (2) 20d COMMON (4" X 0.192"); OR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS: OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN (3) 16d COMMON (3 1/2" X 0.161"); OR (4) 10d BOX (3" X 0.128"); OR (4) 3" X 0.131" NAILS: OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN (3) 16d COMMON (3 1/2" X 0.161"); OR (4) 10d BOX (3" X 0.128"); OR (4) 3" X 0.131" NAILS: OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN (2) 8d COMMON (2 1/2" X 0.131"); OR (2) 10d BOX (3" X 0.128"); OR (2) 3" X 0.131" NAILS: OR (2) 3" 14 GAGE STAPLES, 7/16" CROWN 29. BRIDGING OR BLOCKIN TO JOIST, RAFTER OR TRUSS 28. JOIST TO BAND OR RIM JOIST 27. LEDGER STRIP SUPPORTING JOIST OR RAFTERS 26. BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS 25. 2" PLANK (PLANK AND BEAM - FLOOR AND ROOF) 24. 2" SUBFLOOR TO JOIST OR GIRDER 23. 1" X 6" SUBFLOOR OR LESS TO EACH JOIST 30. 3/8" -1/2"h WOOD STRUCTURAL PANELS (WSP), SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING TO FRAMING AND PARTICALBOARD WALL SHEATHING TO FRAMINGa 31. 19/32" -3/4" h 32. 7/8" -1 1/4" h OTHER EXTERIOR WALL SHEATHING 33. 1/2" FIBERBOARD SHEATHING b 34. 25/32" FIBERBOARD SHEATHING b WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING 35. 3/4" AND LESS h 36. 7/8" -1" h 37. 1 1/8" -1 1/4" h PANEL SIDING TO FRAMING 38. 1/2" OR LESS h 39. 5/8" h INTERIOR PANELING 40. 1/4" 41. 3/8"6d CASING (2" X 0.099"); OR 6d FINISH (PANEL SUPPORTS AT 24") 4d CASING (1 1/2" X 0.080"); OR 4d FINISH (1 1/2" X 0.072") 8d CORROSION-RESISTANT SIDING (2 3/8" X 0.128"); OR 8d CORROSION-RESISTANT CASING (2 1/2" X 0.113") 6d CORROSION-RESISTANT SIDING (1 7/8" X 0.106"); OR 6d CORROSION-RESISTANT CASING (2" X 0.099") 6" 6" 6" 12" 12" 12" 12" 6"12" 6"12" 6"12"8d COMMON (2 1/2" X 0.131"); OR 6d DEFORMED (2" X 0.113") 8d COMMON (2 1/2" X 0.131"); OR 8d DEFORMED (2 1/2" X 0.131") 10d COMMON (3" X 0.148"); OR 8d DEFORMED (2 1/2" X 0.131") 1 1/2" GALVANIZED ROOFING NAIL (7/16" HEAD DIAMETER); OR 1 1/4" 16 GAGE STAPLE WITH 7/16" OR 1" CROWN 1 3/4" GALVANIZED ROOFING NAIL (7/16" HEAD DIAMETER); OR 1 1/2" 16 GAGE STAPLE WITH 7/16" OR 1" CROWN 3"6" 3"6" 6"12" 4"8" 6" e 6" e 6"12" 8d COMMON (2 1/2" X 0.131"); OR 6d DEFORMED (2" X 0.113") (SUBFLOOR AND WALL) 8d COMMON OR DEFORMED (2 1/2" X 0.131") (ROOF); OR RSRS-01 (2 3/8" X 0.113") NAIL (ROOF)d 2 3/8" X 0.113 NAIL; OR 2" 16 GAGE STAPLE W/ 7/16" CROWN 10d COMMON (3" X 0.148"); OR 8d DEFORMED (2 1/2" X 0.131") DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERS EDGES (INCHES) 6"12" 6" e 6" e 4"8" 4"8" 3" f 3" f 3" f 3" f INTERMEDIATE SUPPORTS (INCHES) 6d COMMON DEFORMED (2" X 0.113") (SUBFLOOR AND WALL) 8d COMMON DEFORMED (2 1/2" X 0.113") (ROOF); OR RSRS-01 (2 3/8" X 0.113") NAIL (ROOF)d 2 3/8" X 0.266" HEAD NAIL (ROOF) 1 3/4" 16 GAGE STAPLE W/ 7/16" CROWN (SUBFLOOR AND WALL) 2 3/8" X 0.113 NAIL (ROOF) 1 3/4" 16 GAGE STAPLE W/ 7/16" CROWN (ROOF) NOTES: a. NAILS SPACED AT 6 INCHES AT INTERMEDIATE SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO WOOD SHEAR WALL SCHEDULE AND NOTES. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX, OR CASING b. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS FOR NON-STRUCTURAL APPLICATIONS. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED) c. WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE, THE NUMBER OF TOENAILS IN THE RAFTER SHALL BE PERMITTED TO BE REDUCED BY ONE NAIL. d. RSRS-01 IS A SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667. e. TABULATED FASTENER REQUIREMENTS APPLY WHERE THE ULTIMATE DESIGN WIND SPEED IS LESS THAN 140 MPH. FOR WOOD STRUCTURAL PANEL ROOF SHEATHING ATTACHED TO GABLE END ROOF FRAMING AND TO INTERMEDIATE SUPPORTS WITHIN 48 INCHES OF ROOF EDGES AND RIDGES, NAILS SHALL BE SPACED AT 4 INCHES ON CENTER WHERE THE ULTIMATE WIND SPEED IS GREATER THAN 130 MPH IN EXPOSURE B OR GREATER THAN 110 MPH IN EXPOSURE C. SPACING EXCEEDING 6 INCHES ON CENTER AT INTERMEDIATE SUPPORTS SHALL BE PERMITTED WHERE THE FASTENING IS DESIGNED PER THE AWS NDS. f. FASTENING IS ONLY PERMITTED WHERE THE ULTIMATE DESIGN WIND SPEED IS LESS THAN OR EQUAL TO 110 MPH g. NAILS AND STAPLES ARE CARBON STEEL MEETING THE SPECIFICATIONS OF ASTM F1667. CONNECTIONS USING NAILS AND STAPLES OF OTHER MATERIALS, SUCH AS STAINLESS STEEL, SHALL BE DESIGNED BY ACCEPTABLE ENGINEERING PRACTICE APPROVED UNDER SECTION 104.11. h. SEE WOOD CONSTRUCTION GENERAL NOTES SECTIONS C, D, AND E FOR MINIMUM NAIL SIZES TO BE USED AT FLOOR SHEATHING (TO FRAMING), ROOF SHEATHING (TO FRAMING), AND SHEAR WALL SHEATHING (TO FRAMING), RESPECTIVELY. SEE PLANS FOR HIGH LOAD DIAPHRAGM NAILING AND CORRESPONDING BLOCKING WHERE OCCURS. 4. CEILING JOIST ATTACHED TO PARALLEL RAFTER (HEEL JOINT) (3) 10d COMMON (3" X 0.148"); OR (4) 10d BOX (3" X 0.128"); OR (4) 3" X 0.131" NAILS: OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN 5. COLLAR TIE TO RAFTER (3) 10d COMMON (3" X 0.148"); OR (3) 16d BOX (3 1/2" X 0.135"); OR (4) 10d BOX (3" X 0.128" NAILS; OR (4) 3" X 0.131" NAILS; OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN 6. RAFTER OR TRUSS TO TOP PLATE 7. ROOF RAFTER TO RIDGE VALLEY OR HIP RAFTERS; OR ROOF RAFTER TO 2 INCH RIDGE BEAM (3) 16d COMMON (3 1/2" X 0.162"); OR (4) 10d BOX (3" X 0.128"); OR (4) 3" X 0.131" NAILS: OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN FACE NAIL (2) 16d COMMON (3 1/2" X 0.162"); OR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS: OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN END NAIL (3) 10d COMMON (3" X 0.148"); OR (4) 16d BOX (3 1/2" X 0.135"); OR (4) 10d BOX (3" X 0.128" NAILS; OR (4) 3" X 0.131" NAILS; OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN 8. STUD TO STUD (NOT AT BRACED WALL PANELS) 9. STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS (AT BRACED WALL PANELS) 16d COMMON (3 1/2" X 0.162") 10d BOX (3" X 0.128"); OR 3" X 0.131" NAILS: OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN 16" O.C. FACE NAIL 16d COMMON (3 1/2" X 0.162"); OR 12" O.C. FACE NAIL16d BOX (3 1/2" X 0.162"); OR 3" X 0.131" NAILS: OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN 12" O.C. FACE NAIL 10. BUILT-UP HEADER (2" TO 2" HEADER) 11. CONTINUOUS HEADER TO STUD 12. TOP PLATE TO TOP PLATE 13. TOP PLATE TO TOP PLATE, AT END JOINTS 14. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST, OR BLOCKING (NOT AT BRACED WALL PANELS) 15. BOTTOM PLATE TO JOIST, RIM JOIST, BAND JOIST, OR BLOCKING AT BRACED WALL PANELS 16d COMMON (3 1/2" X 0.162"); OR 16d BOX (3 1/2" X 0.162"); OR (4) 8d COMMON (2 1/2" X 0.131"); OR (4) 10d BOX (3" X 0.128"); OR 12" O.C. EACH EDGE, FACE NAIL 16d COMMON (3 1/2" X 0.162"); OR (4) 10d BOX (3" X 0.128" NAILS; OR (4) 3" X 0.131" NAILS; OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN (8) 16d BOX (3 1/2" X 0.135"); OR (12) 10d BOX (3" X 0.128" NAILS; OR (12) 3" X 0.131" NAILS; OR (12) 3" 14 GAGE STAPLES, 7/16" CROWN 16d COMMON (3 1/2" X 0.162"); OR 16d BOX (3 1/2" X 0.135"); OR 3" X 0.131" NAILS; OR 3" 14 GAGE STAPLES, 7/16" CROWN (4) 8d COMMON (2 1/2" X 0.131"); OR (4) 10d BOX (3" X 0.128"); OR (4) 3" X 0.131" NAILS; OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN (2) 16d COMMON (3 1/2" X 0.162"); OR (3) 16d BOX (3 1/2" X 0.135"); OR (4) 3" X 0.131" NAILS; OR (4) 3" 14 GAGE STAPLES, 7/16" CROWN 16. STUD TO TOP OR BOTTOM PLATE (2) 16d COMMON (3 1/2" X 0.162"); OR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS; OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN 17. TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS (2) 16d COMMON (3 1/2" X 0.162"); OR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS; OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN 19. 1" X 6" SHEATHING TO EACH BEARING (2) 8d COMMON (2 1/2" X 0.131"); OR (2) 10d BOX (3" X 0.128") 18. 1" BRACE TO EACH STUD AND PLATE (2) 8d COMMON (2 1/2" X 0.131"); OR (2) 10d BOX (3" X 0.128"); OR (2) 3" X 0.131" NAILS; OR (2) 3" 14 GAGE STAPLES, 7/16" CROWN 20. 1" X 8" AND WIDER SHEATHING TO EACH BEARING (2) 8d COMMON (2 1/2" X 0.131"); OR (2) 10d BOX (3" X 0.128") DESCRIPTION OF BUILDING ELEMENTS (3) 8d COMMON (2 1/2" X 0.131"); OR FLR (3) 10d BOX (3" X 0.128"); OR (3) 3" X 0.131" NAILS: OR (3) 3" 14 GAGE STAPLES, 7/16" CROWN TOENAIL21. JOIST TO SILL, TOP PLATE, OR GIRDER 6" O.C. TOE NAIL 8d COMMON (2 1/2" X 0.131"); OR 10d BOX (3" X 0.128"); OR 3" X 0.131" NAILS: OR 3" 14 GAGE STAPLES, 7/16" CROWN 22. RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL, OR OTHER FRAMING BELOW WD5.1 CONTINUOUS ROD ROOF UPLIFT RESTRAINT SYSTEM GENERAL NOTES: A. THE CONTINUOUS ROD ROOF UPLIFT RESTRAINT SYSTEM SPECIFIED AND SCHEDULED FOR THIS PROJECT IS BASED ON THE SIMPSON STRONG-TIE “STRONG-ROD UPLIFT RESTRAINT SYSTEM FOR ROOFS”(URS) OR APPROVED EQUAL. B. THE URS IS BE RESTRAINED BY A BEARING PLATE AND TAKE-UP DEVICE ASSEMBLY AT THE ROOF. C. DO NOT WELD PRODUCTS UNLESS THE URS INSTALLATION DETAILS SPECIFICALLY IDENTIFY A PRODUCT AS ACCEPTABLE FOR WELDING. RODS, NUTS, AND COUPLER NUTS SHALL NOT BE WELDED. D. IN THE EVENT OF A DISCREPANCY BETWEEN THESE STRUCTURAL DRAWINGS AND THE URS INSTALLATION DETAILS, THESE STRUCTURAL DRAWINGS SHALL GOVERN. E. THE STRUCTURAL DRAWINGS ARE SPECIFIC TO THE SIMPSON STRONG-TIE STRONG-ROD UPLIFT RESTRAINT SYSTEM FOR ROOFS (URS) AND ARE NOT APPLICABLE TO OTHER MANUFACTURERS’CONTINUOUS ROD UPLIFT RESTRAINT SYSTEMS. PROPOSED SUBSTITUTIONS OF OTHER MANUFACTURERS’CONTINUOUS ROD UPLIFT RESTRAINT SYSTEMS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL. SUBMITTAL SHALL INCLUDE EVALUATION REPORTS INDICATING COMPLIANCE WITH GOVERNING BUILDING CODES AND TEST DATA DEEMED ACCEPTABLE TO THE BUILDING OFFICIAL. IN ADDITION, SUBMITTAL SHALL INCLUDE INSTALLATION DETAILS AND INSTRUCTIONS, CALCULATIONS IN ACCORDANCE WITH THE GOVERNING BUILDING CODES, AND CERTIFICATION BY THE MANUFACTURER OF COMPLIANCE WITH THESE URS SPECIFICATIONS AND THE STRUCTURAL DRAWINGS. F. URS RUN START/TERMINATIONS SHALL BE AS SET FORTH ON THESE STRUCTURAL DRAWINGS. ALTERNATE RUN START/TERMINATIONS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO CONCRETE PLACEMENT. SUBMITTAL SHALL INCLUDE CALCULATIONS IN COMPLIANCE WITH THE GOVERNING BUILDING CODE, INCLUDING CONCRETE ANCHORAGE IN ACCORDANCE WITH ACI 318 PROVISIONS FOR STRENGTH DESIGN AND CONVERSION TO ASD LOAD LEVELS. G. A PRE-CONSTRUCTION MEETING IS RECOMMENDED WITH SIMPSON STRONG-TIE PRIOR TO PLACEMENT OF THE CONCRETE. THE PURPOSE OF THIS MEETING IS TO ASSIST IN VERIFYING QUANTITIES AND UNDERSTANDING THE INSTALLATION PROCESS. TO COORDINATE THIS MEETING, CALL SIMPSON STRONG-TIE AT (800) 999-5099. NOTES: 1. DRYWALL STACKING DURING CONSTRUCTION IS PERMITTED ONLY AS SHOWN IN ABOVE DETAIL. 2. WHEN STACKED VERTICALLY, NO MORE THAN 12 SHEETS MAY BE STACKED TOGETHER AND MAY BEAR ON THE DECK NO MORE THAN 1'-8 FROM LOAD BEARING WALL. STACK SHEETS ON THEIR LONG END (SHORT SIDE UP). 3. WHEN LAID FLAT, NO MORE THAN 18 SHEETS MAY BE STACKED TOGETHER. 4. DRYWALL STACKS SHALL NOT BE DROPPED ONTO DECK. DECK IS NOT RATED FOR HEAVY IMPACT LOADS, AND STRUCTURAL DAMAGE MAY OCCUR FROM DROPPING EVEN PARTIAL DRYWALL STACKS. 5. SLEEPERS ARE NOT PERMITTED UNDER DRYWALL STACKS. STACKS SHALL BEAR DIRECTLY ON DECK SUCH THAT THEIR WEIGHT IS DISTRIBUTED EQUALLY ALONG THEIR LENGTH. 6. DRYWALL STACKS ARE NOT PERMITTED ON CANTILEVERS AND SHALL NOT OVERHANG THE BEARING WALL. 7. MAINTAIN A MINIMUM OF 2'-0 CLEAR SPACE AROUND DRYWALL STACKS WITH NO OTHER MATERIAL STORAGE. NO OTHER MATERIAL STORAGE IS PERMITTED ADJACENT TO VERTICALLY STACKED DRYWALL IN CORRIDORS. LOAD BEARING WOOD STUD WALL (12) SHEETS OF DRYWALL MAXIMUM WHEN STACKED VERTICALLY(18) SHEETS MAXIMUM WHEN LAID FLAT APPROXIMATELY 4' - 0" STACKING OF DRYWALL NOT PERMITTED ON CANTILEVERS (EITHER VERTICALLY OR FLAT) STACKING OF DRYWALL NOT PERMITTED WHERE TRUSS SPAN IS PARALLEL TO LOAD BEARING WALL (VERTICALLY) 1' - 8" MAX NO OTHER MATERIAL STORAGE PERMITTED ADJACENT TO VERTICALLY STACKED DRYWALL IN CORRIDORSMAINTAIN 2'-0 MIN. CLEAR SPACE ALL AROUND DRYWALL STACKS WITH NO OTHER MATERIAL STORAGE (TYP) Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:16:30 PMS0.301 General Notes - Wood Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/2" = 1'-0"1 Drywall Stacking Over Load Bearing Wood Stud Walls No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 INTERIOR NON-LOAD BEARING PARTITION WALL -RE: ARCH. (NOTE WALL MAY HAVE ONE TOP PLATE AT OPTION OF FRAMER) FLOOR SHEATHING 2x BLOCKING BETWEEN TRUSS LAID FLAT AT 24" O.C. MAX -TOE NAIL TO TRUSS TOP / BOTTOM CHORD FLOOR TRUSS INTERIOR NON-LOAD BEARING PARTITION WALL - RE: ARCH. (NOTE WALL MAY HAVE ONE TOP PLATE AT OPTION OF FRAMER) FLOOR SHEATHINGFLOOR TRUSS Wall Parallel Between Trusses Wall Perpendicular to Trusses 3/4"BLOCKING AS REQUIRED FOR CEILING INSTALLATION DEFLECTION SCREW NOTE: 1. PROVIDE MINIMUM (2) SCREWS PER WALL 2. SCREWS TO BE LOCATED 2'-0" MAXIMUM FROM END OF WALL 3. INSTALL SCREWS PER MANUFACTURS INSTALLATION INSTRUCTIONS INTERIOR NON-LOAD BEARING PARTITION WALL - RE: ARCH. (NOTE WALL MAY HAVE ONE TOP PLATE AT OPTION OF FRAMER) PROVIDE FASTENMASTER NLB SCREW CONNECTOR AT 48" O.C MAX. OR SIMPSON DEFLECTOR SCREW AT 24" O.C. MAX. (AT 1X UPPER TOP PLATE USE SIMPSON SDPW14500, AT 2X UPPER TOP PLATE USE SIMPSON SDPW19600) INTERIOR NON-LOAD BEARING PARTITION WALL - RE: ARCH. (NOTE WALL MAY HAVE ONE TOP PLATE AT OPTION OF FRAMER) FLOOR SHEATHING 2X REQUIRED FOR CEILING INSTALLATION FLOOR TRUSS Wall Parallel Aligned withTruss 3/4"CONT DOUBLE TOP PLATE (AT CONTRACTORS OPTION, UPPER TOP PLATE MAY BE 1X OR 2X WITH 2X LOWER TOP PLATE)3/4"BLOCKING BELOW BOTTOM PLATE PROVIDE FASTENMASTER NLB SCREW CONNECTOR AT 48" O.C MAX. OR SIMPSON DEFLECTOR SCREW AT 24" O.C. MAX. (AT 1X UPPER TOP PLATE USE SIMPSON SDPW14500, AT 2X UPPER TOP PLATE USE SIMPSON SDPW19600) BLOCKING AS REQUIRED FOR CEILING INSTALLATION BLOCKING BELOW BOTTOM PLATE PROVIDE FASTENMASTER NLB SCREW CONNECTOR AT 48" O.C MAX. OR SIMPSON DEFLECTOR SCREW AT 24" O.C. MAX. (AT 1X UPPER TOP PLATE USE SIMPSON SDPW14500, AT 2X UPPER TOP PLATE USE SIMPSON SDPW19600) CEILING INSTALLATION TO BE INSTALLED TO ACCOMMODATE WALL VERTICAL MOVEMENT - FOR RECOMENED METHODS SEE DETAIL INTERIOR NON-LOAD BEARING PARTITION WALL - RE: ARCH. (NOTE WALL MAY HAVE ONE TOP PLATE AT OPTION OF FRAMER) CONT DOUBLE TOP PLATE (AT CONTRACTORS OPTION, UPPER TOP PLATE MAY BE 1X OR 2X WITH 2X LOWER TOP PLATE) CEILING INSTALLATION TO BE INSTALLED TO ACCOMMODATE WALL VERTICAL MOVEMENT - FOR RECOMENED METHODS SEE DETAIL INTERIOR NON-LOAD BEARING PARTITION WALL - RE: ARCH. (NOTE WALL MAY HAVE ONE TOP PLATE AT OPTION OF FRAMER) CONT DOUBLE TOP PLATE (AT CONTRACTORS OPTION, UPPER TOP PLATE MAY BE 1X OR 2X WITH 2X LOWER TOP PLATE) CEILING INSTALLATION TO BE INSTALLED TO ACCOMMODATE WALL VERTICAL MOVEMENT - FOR RECOMENED METHODS SEE DETAIL /7 S0.302/7 S0.302/7 S0.302 CONVENTIONAL 3 STUD 2 STUD / CLIP (NON-LOAD BEARING / NON-SHEAR WALL CONDITIONS ONLY) TWO STUD CONFIGURATION THREE STUD "CALIFORNIA" CONFIGURATION SCHEDULED WALL STUDS CONVENTIONAL CORNER BLOCKED STUD CONFIGURATION SCHEDULED WALL STUDS SCHEDULED WALL STUDS 2X6 2X4 PREST-ON OR EQUAL DRYWALL FASTENERS INSTALLED PER MANUFACTURERS RECOMMENDATIONS FLUSH TOP PLATES EXTEND UPPER TOP PLATE AND ATTACH W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) SEE CORNER STUD CONFIGURATION OPTIONS EXTEND TALLER WALL UPPER AND LOWER TOP PLATE OVER SHORTER WALL AND ATTACH W/ (2) SIMPSON SDWS22600 SCREWS SEE CORNER STUD CONFIGURATION OPTIONS ONE PLATE OFFSET CORNER EXTEND TALLER WALL UPPER TOP PLATE OVER SHORTER WALL AND ATTACH W/ (2) SIMPSON SDWS22500 SCREWS SEE CORNER STUD CONFIGURATION OPTIONS TWO PLATE OFFSET CORNER DOUBLE TOP PLATE TWO PLATE OFFSET DOUBLE TOP PLATE ONE PLATE OFFSET EXTEND TALLER WALL UPPER AND LOWER TOP PLATE OVER SHORTER WALL AND ATTACH W/ (2) SIMPSON SDWS22600 SCREWS GREATER THAN TWO PLATE OFFSET CORNER EXTENTS OF SHORTER WALL E X T E N T S O F T A LLE R W A LLEXTE NTS O F S H O RTE R W ALL E XTE NTS O F S H O RTE R W ALLDOUBLE TOP PLATE> TWO PLATEOFFSETE X T E N T S O F T A LLE R W A LLE X T E N T S O F T A LLE R W A LLSEE INTERSECTION STUD CONFIGURATION OPTIONS NOTE: ON PREFAB WALLS, UPPER TOP PLATE TO BE INSTALLED IN FIELD TO ALLOW WALLS TO BE TIED TOGETHER AT CORNER AND INTERSECTION CONDITIONS. PROVIDE 2X BLOCKING - ATTACH TO LOWER WALL TOP PLATE W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) OR (2) SIMPSON SDWS22400 SCREWS 10" MIN FLUSH TOP PLATES EXTEND INTERSECTING WALL UPPER TOP PLATE OVER LOWER TOP PLATE AND ATTACH W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) (SEE NOTE 2) SEE INTERSECTION STUD CONFIGURATION OPTIONS EXTEND UPPER BLOCKING FROM INTERSECTING AND ATTACH W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) OR (2) SIMPSON SDWS22300 SCREWS (SEE NOTE 2) SEE INTERSECTION STUD CONFIGURATION OPTIONS DOUBLE TOP PLATE TWO PLATE OFFSET PROVIDE (2) LAYERS OF 2X BLOCKING -ATTACH TO LOWER WALL TOP PLATE W/ (2) SIMPSON SDWS22600 SCREWS ONE PLATE OFFSET TEE (INTERSECTION WALL SHORTER) EXTEND BLOCKING FROM INTERSECTING WALL AND ATTACH W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) OR (2) SIMPSON SDWS22300 SCREWS (SEE NOTE 2) SEE INTERSECTION STUD CONFIGURATION OPTIONS DOUBLE TOP PLATE ONE PLATE OFFSET PROVIDE (1) LAYER OF 2X BLOCKING -ATTACH TO LOWER WALL TOP PLATE W/ (2) SIMPSON SDWS22400 SCREWS 10" MIN TWO PLATE OFFSET TEE (INTERSECTION WALL SHORTER) 2X BLOCKING TO MATCH WALL PLATES BETWEEN SCHEDULED STUDS AT INTERSECTING WALL SEE INTERSECTION STUD CONFIGURATION OPTIONS EXTENTS OF GREATER THAN TWO PLATE OFFSET TEE (INTERSECTION WALL SHORTER) INTERSECTING WALL EXTEND LOWER INTERSECTING UPPER TOP PLATE OVER BLOCKING AT TALLER WALL AND ATTACH W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) OR (2) SIMPSON SDWS22300 SCREWS (SEE NOTE 2)DOUBLE TOP PLATE> TWO PLATEOFFSETSIMPSON A35 CLIP AT EACH END OF BLOCKING SEE INTERSECTION STUD CONFIGURATION OPTIONS GREATER THAN TWO PLATE OFFSET TEE (INTERSECTION WALL TALLER)DOUBLE TOP PLATE> TWO PLATEOFFSETEXTENTS OF INTERSECTING WALL EXTEND INTERSECTING WALL UPPER TOP PLATE OVER LOWER WALL TOP PLATES AND (1) LAYER OF BLOCKING AND ATTACH W/ (2) SIMPSON SDWS22600 SCREWS (SEE NOTE 2) SEE INTERSECTION STUD CONFIGURATION OPTIONS DOUBLE TOP PLATE TWO PLATE OFFSET TWO PLATE OFFSET TEE (INTERSECTION WALL TALLER) ONE PLATE OFFSET TEE (INTERSECTION WALL TALLER) EXTEND UPPER TOP PLATE FROM INTERSECTING WALL AND ATTACH W/ (5) 16d COMMON (3 1/2" X 0.162"⌀) OR (2) SIMPSON SDWS22400 SCREWS (SEE NOTE 2) SEE INTERSECTION STUD CONFIGURATION OPTIONS DOUBLE TOP PLATE ONE PLATE OFFSET E XTE NTS O F TALLE R W ALL EXTE NTS O F TALLE R W ALL NOTE: 1. ON PREFAB WALLS, UPPER TOP PLATE TO BE INSTALLED IN FIELD TO ALLOW WALLS TO BE TIED TOGETHER AT CORNER AND INTERSECTION CONDITIONS. 2. DOUBLE TOP PLATES AT EXTERIOR CONDITIONS ARE NOT REQUIRED TO OVERLAP WHEN SHEATHING IS RUN CONTINUOUS AT INTERIOR FACE OF EXTERIOR WALL AND WALL INTERSECTING STUDS CONFIGURATIONS ARE SCREWED TOGETHER. EXTENTS OF SHORTER WALL 10" MIN EXTENTS OF SHORTER WALL BLOCKING CONVENTIONAL T-STUD LADDER BACKING 2X4 LADDER BLOCKING AT 16" O.C. TEE "T" STUD CONFIGURATION (NOTE: AT EXTERIOR CONDITION, SHEATHING MAY RUN BETWEEN EXTERIOR WALL STUDS AND FIRST INTERIOR WALL STUD - SCREW INTERIOR WALL STUD TO EXTERIOR STUD W/ SDWS22500 @ 12" O.C. STAGGERED) SCHEDULED WALL STUDS CONVENTIONAL CHANNEL "T" STUD CONFIGURATION (NOTE: AT EXTERIOR CONDITION, SHEATHING MAY RUN BETWEEN EXTERIOR WALL STUDS AND FIRST INTERIOR WALL STUD) SCHEDULED WALL STUDS SCHEDULED WALL STUDS PREST-ON OR EQUAL DRYWALL FASTENERS INSTALLED PER MANUFACTURERS RECOMMENDATIONS (NOTE: DRYWALL FASTNER NOT REQUIRED IF GYP IS RUN CONTINUOUS) PREST-ON OR EQUAL DRYWALL FASTENERS INSTALLED PER MANUFACTURERS RECOMMENDATIONS (NOTE: DRYWALL FASTNER NOT REQUIRED IF GYP IS RUN CONTINUOUS) CONVENTIONAL T-STUD LADDER BACKING 2X4 LADDER BLOCKING AT 16" O.C. TEE "T" STUD CONFIGURATION SCHEDULED WALL STUDS CONVENTIONAL CHANNEL "T" STUD CONFIGURATION SCHEDULED WALL STUDS SCHEDULED WALL STUDS PREST-ON OR EQUAL DRYWALL FASTENERS INSTALLED PER MANUFACTURERS RECOMMENDATIONS PREST-ON OR EQUAL DRYWALL FASTENERS INSTALLED PER MANUFACTURERS RECOMMENDATIONS STANDARED INTERSECTION DEMISING WALL INTERSECTION OR 4 1/2" SDWC15450 TYPICAL OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS 1 LAYER -NON-SHEARWALL) OPTIONAL AT EXTERIOR (SHEATHING CONTINUOUS 1 OR 2 LAYERS -SHEAR WALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED NAIL PER NAILING SCHEDULE TOE-NAIL LADDER BLOCKING PER NAILING SCHEDULE TOE-NAIL LADDER BLOCKING PER NAILING SCHEDULE ATTACH LADDER BLOCKING W/ (2) SDWC15450 EA. SIDE SDWS22500 SCREWS @ 12" O.C. STAGGERED SDWS22600 SCREWS @ 12" O.C. TYPICAL OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - NON-SHEARWALL) OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - SHEARWALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. NAIL PER NAILING SCHEDULE TYPICAL OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - NON-SHEARWALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED NAIL PER NAILING SCHEDULE SDWS22500 SCREWS @ 12" O.C. STAGGERED OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - SHEARWALL) TYPICAL OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - NON-SHEARWALL) OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - SHEARWALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED NAIL PER NAILING SCHEDULE TOE-NAIL LADDER BLOCKING PER NAILING SCHEDULE TOE-NAIL LADDER BLOCKING PER NAILING SCHEDULE ATTACH LADDER BLOCKING W/ (2) SDWC15450 EA. SIDE SDWS22500 SCREWS @ 12" O.C. STAGGERED (AT SHEAR WALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED (AT NON-SHEAR WALL) SDWS22600 SCREWS @ 12" O.C. TYPICAL OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - NON-SHEARWALL) OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - SHEARWALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. NAIL PER NAILING SCHEDULE OR NAIL PER NAILING SCHEDULE 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. SDWS22500 SCREWS @ 12" O.C. OR OR 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED (TYP) OR TYPICAL OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - NON-SHEARWALL) OPTIONAL AT EXTERIOR (SHEATHING CONTINUOS - SHEARWALL) OR SDWS22500 SCREWS @ 12" O.C. STAGGERED (AT SHEAR WALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED (AT NON-SHEAR WALL) SDWS22500 SCREWS @ 12" O.C. STAGGERED (AT SHEAR WALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED (AT NON-SHEAR WALL) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED (TYP) 0.148"⌀X 3 1/2" COMMON NAILS @ 12" O.C. STAGGERED (TYP) NAIL PER NAILING SCHEDULE (TYP) NAIL PER NAILING SCHEDULE (TYP) 16" 3/4" 8" DISTANCE TO FIRST ATTACHMENT POINT AT CEILING 16" MIN MIN DISTANCE FROM FIRST ATACHMENT POINT AT CEILING TO PANEL EDGE DISTANCE TO FIRST ATTACHMENT POINT AT WALL PREST-ON OR EQUAL DRYWALL FASTENERS INSTALLED TO CEILING SHEATHING / WALL DOUBPE TOP PLATE PER MANUFACTURERS RECOMMENDATIONS 3/4" 1/4" MIN RELIEF JOINT WALL VERT RELIEF JOINT (PREFERED METHOD) CEILING HINGE (ALTERNATE METHOD) NOTE: CEILING INSTALLATION METHODS SHOWN ARE FOR REFERENCE ONLY. RE: ARCH. PROVIDE BACKER ROD / CAULK AT RELIEF JOINT - RE: ARCH. CEILING SHEATHING INSTALLED TO RESILIENT CHANNELS WHERE APPLICABLE CEILING SHEATHING INSTALLED TO RESILIENT CHANNELS WHERE APPLICABLE DEFLECTION SCREW DEFLECTION SCREW Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:16:36 PMS0.302 Typical Framing Details - Wood Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"6 Non Load Bearing Wall Connection 1" = 1'-0"1 Wall Corner Stud Configurations 1" = 1'-0"3 Wall Corner Top Plate Connections 1" = 1'-0"4 Wall Intersection Top Plate Connections 1" = 1'-0"2 Wall Intersection Stud Configurations 1" = 1'-0"7 Ceiling Sheating at Non-Load Bearing Wall No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B C EQEQEQ EQ EQEQEQ EQ PROVIDE (2) 2X MIN STUD PACK AT END OF LEDGER (FASTEN LEDGER TO INNER STUD OF STUD PACK HATCHED AREAS INDICATE ZONES IN LEDGER FOR PENETRATIONS. .. NO OPENING IN LAST STUD BAY AT END OF LEDGER SKIP STUD BAY BETWEEN OPENINGS. NO OPENINGS ALLOWED IN ADJACENT BAYS. LEDGER PENETRATION / FASTENING SCHEDULE 2 X 8 LEDGER SIZE 2 X 12 4" ⌀ PENETRATION (MAX DIA) 8" ⌀ SDWS22400 SCREWS NOTE: 1. SCREWS SHALL PENETRATE 2½" MINIMUM INTO CENTER OF 2X WALL MEMBERS BEHIND LEDGER. SCREWS SHALL MEET SPACING AND EDGE DIMENSIONS SHOWN IN DETAIL BASED ON LEDGER SIZE AND INSTALLATION LOCATION. 2. INSTALLATION BASED ON TESTED CAPACITIES PER ICC-ESAC2 3. INSTALLATION BASED ON TESTED CAPACITIES PER ICC-ESAC233 AS PROVIDED BY SIMPSON STRONG-TIE. 4. LEDGER MAY BE INSTALLED OVER 1 OR 2 LAYERS OF SHEATING AS APPLICABLE. 5. SHEATHING MAY BE WOOD STRUCTURAL PANEL (OSB OR PLYWOOD) OR GYPSUM BOARD. 6. PROVIDE 2X BLOCK AS NEEDED FOR EDGE NAILING (WHEN LEDGER IS NOT INSTALLED OVER SHEATHING) 7. "MAX" CONDITION TO BE USED WHEN SPECIFIED ON PLAN, SEE DETAIL BELOW. DIRECTLY APPLIED TO STUD 6 APPLIED OVER (1) LAYER OF SHEATHING APPLIED OVER (2) LAYER OF SHEATHING FASTENERS LEDGER STUDS 2 X10 6" ⌀ SDWS22400 SCREWS SDWS22600 SCREWS SDWS22600 SCREWS SDWS22600 SCREWS SDWS22600 SCREWS SDWS22600 SCREWS SDWS22600 SCREWS SDWS22600 SCREWS1 1/2"3 1/2"2 1/4"2 1/2"3 1/2"1 1/4"(2) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW LEDGER -SEE PLAN / DETAILS 2 1/4"3 1/2"2 5/8"7/8"1 1/2"2 5/8"2 5/8"2 1/2"2X8 LEDGER 2X12 LEDGER2X10 LEDGER2"3"2 1/4"2 1/4"3"3 1/4"3/4"2 1/4"3"3 1/4"2 3/4"2 1/4"3 1/2"2 5/8"2 7/8"EQ EQ EQ (2) ADD'L SCHEDULED SCREWS AT "MAX" CONDITION INTO PLATE / BLOCKING EQUALLY SPACED BETWEEN STUDS SECONDARY LEDGER AS APPLICABLE TO BE FASTENED DIRECTLY TO PRIMARY LEDGER W/ SDWS22400 SCREWS @ 12" O.C. STAGGERED. (PROVIDE 2 SCREWS EA END)2"2"FASTEN PRIMARY LEDGER TO STUDS PER DETAILS ABOVE PRIMARY LEDGER SECONDARY LEDGER "MAX" CONDITION SECONDARY LEDGER ATTACHMENT 4 1/2"1' - 0"1' - 0"1' - 0"7/8"2 5/8"2 5/8"2 5/8"2 1/2"LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS LEDGER -SEE PLAN / DETAILS (2) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (2) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (3) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (3) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (3) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (3) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (4) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW (3) SCREWS @ 16" O.C. (MAXIMUM) -SEE TABLE BELOW SIMPSON SDWC15600 SCREW AT EACH FULL HEIGHT TRANSOM SUPPORT STUD INTO HEADER AT TOP AND INTO BOTTOM PLATE AT BASE. (2) TOTAL TOP AND BOTTOM. UNLESS NOTED OTHERWISE, PROVIDE (2) 2X6 STUD MIN TRANSOM SUPPORT POST AT EA END OF TRANSOM SUPPORT (TRANSOM SUPPORT POST MAY BE COMBINED WITH BEAM / HEADER TRIMMERS) SIMPSON SDWC15600 SCREW AT EACH FULL HEIGHT KING-POST (2) 2X6 (FLATWISE) TRANSOM SUPPORT HEADER (9'-0" MAX SPAN) BEAM / HEADER -SEE PLAN AND SCHEDULE SPAN (S)DEPTH (D)OUTER 1/3 SPAN (0.33S) NOTCHING NOT PERMITTED MIDDLE 1/3 SPAN (0.33S)OUTER 1/3 SPAN (0.33S) MAX D/3 MAXD/6MAXD/42X NOMINAL CUT BEAMS AND PURLINS ENGINEERED BEAMS (GLULAM / LVL / PSL)2" MIN.MAXD/3MAX D/3 MAXD/6SPAN (S)DEPTH (D)OUTER 1/3 SPAN (0.33S) ALLOWABLE PENETRATION ZONE MIDDLE 1/3 SPAN (0.33S)OUTER 1/3 SPAN (0.33S)D/3D/3D/3(MINIMUM) THE LARGEST HOLE 2X DIAMETER OF HEADER / BEAM DEPTH MAX ROUND HOLE SIZE 4 3/8" 5 1/2" 7 1/4" -20" 1"⌀ 1 3/4"⌀ 2"⌀ DASHED LINE INDICATES ALLOWABLE HORIZONTAL PENETRATION ZONE6" CS16 STRAP X 2'-6" CENTERED AT STUD TRANSITION WITH ALL NAIL HOLES FILL, TYP. 0.148"⌀X 3" NAILS @ 4" O.C. STAGGERED 4"1 1/4"4"1 1/4" TRANSITION STUDS SCHEDULED WALL STUDS SCHEDULED WALL STUDS SCHEDULED WALL STUDS SPLICE JOINT LOCATION -LOCATE DIRECTLY OVER STUD WALL DOUBLE TOP PLATE EQUALLY SPACED (STAGGERED) EQUALLY SPACED (STAGGERED) 2'-0" 2'-0" 4'-0" PER FASTENING SCHEDULE SCHEDULE PER FASTENING PER FASTENING SCHEDULE PER FASTENING SCHEDULE 1 1/2" 1 1/2" UPPER TOP PLATE SPLICE NOTES: 1. 2X4 PLATES: (14) 0.148" DIA. X 3" LONG STAGGERED NAILS EA. SIDE OF SPLICE JOINT 2. 2X6 PLATES: (22) 0.148" DIA. X 3" LONG STAGGERED NAILS EA. SIDE OF SPLICE JOINT 3. TYPICAL FACE NAILING: PER FASTENING SCHEDULE 4. SPLICE JOINT LOCATION SHALL OCCUR OVER WALL STUDS. SEE REQUIRED WALL PLATE SPLICE REPAIR DETAIL ABOVE FOR OTHER CONDITIONS (TYPICAL) UPPER TOP PLATE SPLICE TOP PLATE SPLICE AT CHANGE IN STUD DEPTH (STRAP OPTION) LOWER TOP PLATE SPLICE / BOTTOM PLATE SPLICE PER FASTENING SCHEDULE PER FASTENING SCHEDULE PROVIDE (2) SCHEDULED STUDS DIRECTLY UNDER SPLICE -STITCH DOUBLE STUDS TOGETHER PER FASTENING SCHEDULE WALL LOWER TOP PLATE 2X6 UPPER TOP PLATE RIPPED TO 3 1/2" WIDE AT 2X4 WALL INTERSECTION 0.148"⌀X 3" NAILS @ 4" O.C. STAGGERED 4"1 1/4"4"1 1/4" TRANSITION STUDS SCHEDULED WALL STUDS SCHEDULED WALL STUDS TOP PLATE SPLICE AT CHANGE IN STUD DEPTH (NOTCHED UPPER TOP PLATE OPTION) SPLICE JOINT LOCATION -LOCATE DIRECTLY OVER DOUBLE STUDS 2'-0" MIN. STAGGER BETWEEN LOWER AND UPPER TOP PLATE SPLICE LOCATIONS 4'-0" SPLICE JOINT LOCATION -LOCATE DIRECTLY OVER STUD EQUALLY SPACED (STAGGERED) EQUALLY SPACED (STAGGERED) 2'-0" 1 1/2" 1 1/2"2'-0" 1'-0" MIN PER FASTENING PER FASTENING SCHEDULE SCHEDULE SCHEDULE PER FASTENING PER FASTENING SCHEDULE 1 1/2" PER FASTENING SCHEDULE PER FASTENING SCHEDULE 5/8" MIN. MAX 40%D D/4 (D) STUD DEPTH 5/8" MIN. MAX 50%D D/2.5 (D) STUD DEPTH (D) STUD DEPTH EXTERIOR AND LOAD BEARING WALLS INTERIOR NON- LOAD BEARING WALLS PROTECTION AT ELECTRICAL OR PLUMBING WOOD FRAMED LEVEL 60% HOLE HEIGHT (H) 1ST 2ND 3RD 4TH 40% HOLE HEIGHT (H) 1 3/4" 2 15/16" 4" 5 1/4" 2 1/2" 4 1/16" 5 1/8" 7 1/16"⌀ MAX D/6APPROVED NAIL STOPPER PLATE DRILL D/6⌀HOLE BEFORE CUTTING NOTCH IN STUD FOR HOLES LARGER THAN D/6⌀, USE APPROVED STUD SHOE INSTALLED PER MANUFACTURES INSTRUCTIONS OBLONG HOLE HEIGHT CHART (STUDS) STUD DEPTH D/2.5 2X4 (3 1/2") 2X6 (5 1/2") 2X8 (7 1/4") 2X10 (9 1/4") D/4 7/8" 1 3/8" 1 13/16" 2 5/16" 1 3/8" 2 3/16" 2 7/8" 3 11/16" NOTCH SIZE CHART (STUDS) 5/8" MAX 40%D 5/8" MAX 60%D HSTANDARD PENETRATION OBLONG PENETRATIONS FOR SHRINKAGE (INSTALL PLUMBING / CONDUIT AT BOTT OF HOLE TO ACCOUNT FOR SHRINKAGE) STANDARD PENETRATION OBLONG PENETRATIONS FOR SHRINKAGE (INSTALL PLUMBING / CONDUIT AT BOTT OF HOLE TO ACCOUNT FOR SHRINKAGE) STUD DEPTH 60% HOLE DIAMETER 2X4 (3 1/2") 2X6 (5 1/2") 2X8 (7 1/4") 2X10 (9 1/4") 40% HOLE DIAMETER 1 3/8"⌀ 2 3/16"⌀ 2 7/8"⌀ 3 3/4"⌀ 2 1/8"⌀ 3 5/16"⌀ 4 3/8"⌀ 5 9/16"⌀ HOLE SIZE CHART (STUDS)W/2(W)PLATEWIDTHMAX50%W5/8"PLATE WIDTH W/2 NOTCH 2X4 (3 1/2") 2X6 (5 1/2") 2X8 (7 1/4") 2X10 (9 1/4") 50% HOLE DIAMETER 1 3/4"⌀ 2 3/4"⌀ 3 5/8"⌀ 4 5/8"⌀ HOLE / NOTCHSIZE CHART (PLATES) 1 3/4" 2 3/4" 3 5/8" 4 5/8" B PLATE REPAIR FOR NOTCH > 50%WFOR OPENINGS GREATER THAN 50% PLATES MUST BE REINFORCED WALL DOUBLE TOP PLATECTS218 TENSION/COMPRESSION STRAP 2 SIDES OR HARDY SADDLE OR APPROVED EQUAL INSTALLED PER MANUF INSTRUCTIONS W MAX NOTCHES 6'-0" O.C. MIN. BORED HOLES 1'-0" O.C. MIN. C PLATE REPAIR FOR MULTIPLE/LARGE BORED HOLES SCHEDULED STUDS WALL SINGLE BOTTOM PLATE CS16 STRAP EA. PLATE EXTEND BEYOND BORES FILL ENDS W/ NAILS PER MANUF INSTRUCTIONS CS16 STRAP EA. PLATE EXTEND BEYOND BORED HOLES AND FILL ENDS W/ NAILS PER MANUF INSTRUCTIONS CTS218 TENSION/COMPRESSION STRAP 2 SIDES OR APPROVED EQUAL INSTALLED PER MANUF INSTRUCTIONS MAX. 4 1/2" NOTCH AT EXTERIOR AND LOAD BEARING WALL AND SHEAR WALL TOP AND BOTTOM PLATE MULTIPLE/LARGE BORED HOLES AT EXTERIOR AND LOAD BEARING WALL AND SHEAR WALL TOP AND BOTTOM PLATE MAX. 4 1/2"3/4"< 75%W MAX.3/4"ADJACENT BORED HOLES 2" MIN. BETWEEN 1' - 3" MIN.1' - 3" MIN. Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:16:41 PMS0.303 Typical Framing Details - Wood Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Ledger Penetrations / Attachment 1 1/2" = 1'-0"4 Transom Header / Support Post 3/4" = 1'-0"5 Allowable Penetrations in Wood Beams 1" = 1'-0"3 Wall Plate Splice Detail 1" = 1'-0"2 Allowable Notches and Penetrations in Wall Studs and Plates No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WD9.1 WOOD WALL STUD LAYOUT KEY PLAN: EL STEB ENL CSTUD KEY ABBREVIATIONS CORRIDOR WALL CORRIDOR WALL W/ UNIT BEARING UNIT DEMSING WALL C MARK DESCRIPTION CU UD INTERIOR BEARING WALLIB EXTERIOR BEARING WALLEB EXTERIOR NON-LOAD BEARING WALLENL STAIR WALLST ELEVATOR WALLEL ENLUDSTCUDUDUDUDUDUDUDC C CUCCUCUD UD IB IB IBIBENLENLEL ELELIB FIRE WALL WD9.0 WOOD WALL STUD SCHEDULE NOTES: A. STUD SIZES INDICATED ARE THE MINIMUM REQUIRED STRUCTURAL SIZE. CONTRACTOR TO VERIFY STUD WALL WIDTH WITH SIZES INDICATED ON ARCHITECTURAL DRAWINGS PRIOR TO WALL PANEL FABRICATION AND / OR INSTALLATION. B. LOAD BEARING WALLS ARE SHOWN AS SHADED ON PLAN. C. EXTERIOR LOAD BEARING WALLS ARE THOSE WITH FLOOR / ROOF TRUSSES ORIENTED PERPENDICULAR TO EXTERIOR WALL. D. EXTERIOR NON-LOAD BEARING (NLB) WALLS ARE THOSE WITH FLOOR / ROOF TRUSSES ORIENTED PARALLEL TO EXTERIOR WALL. E. STUDS MAY BE SOLID SAWN OR FINGER JOINTED LUMBER OF THE GRADE AND SPECIES SPECIFIED HEREIN. F. ALL SHEAR WALLS SHALL HAVE A MAXIMUM STUD SPACING OF 16" O.C.. REFER TO BRACING PLANS FOR SHEAR WALL LOCATIONS / LENGTHS AS NOT ALL SHEAR WALLS ARE LOAD BEARING WALLS. G. REFER TO SHEAR WALL END ANCHORAGE PLANS FOR ADDITIONAL FRAMING MEMBERS REQUIRED AT SHEAR WALL ENDS. H. SEE FRAMING PLANS AND GENERAL NOTES FOR ADDITIONAL FRAMING MEMBERS NOT SHOWN OR REFERENCED HEREIN. I. STAIRWELL WALL FRAMING: PROVIDE (3) @ 16" @ 12" OC OR (1)2X6 @ 16" O.C. (UNO) FOR WALL HEIGHTS UP TO 13'-6". J. IT IS STRUCTURALLY ACCEPTABLE TO LOCATE RESIDENTIAL UNIT ELECTRICAL PANELS WITHIN 14 1/2" CLEAR STUD BAY. CONTRACTOR TO COORDINATE ELECTRICAL PANEL LOCATIONS PRIOR TO WALL PANEL FABRICATION AND OR INSTALLATION. K. ALL INTERIOR NON-LOAD BEARING WALLS SHALL BE (1)2X4 @ 24" O.C. MAX UNO ON PLAN (TYPICAL) L. PROVIDE 'DEMISING –HEAVY' STUD CONFIGURATION FOR ALL DEMISING WALLS SUPPORTING FLOOR TRUSSES WITH SPAN LENGTHS GREATER THAN 14 FEET. USE 'DEMISING –LIGHT' STUD CONFIGURATION FOR ALL DEMISING WALLS SUPPORTING FLOOR TRUSSES WITH SPAN LENGTHS OF 14 FEET OR LESS. WD10.0 WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. Residential Apartment Bldgs. Stud Schedule (SPF No. 2) CORRIDOR WALLS UNIT DEMISING - LIGHT UNIT DEMISING - HEAVY UNIT INTERIOR EXTERIOR LB EXTERIOR NON-LB 2x4 2x6 2x4 2x6 2x4 2x6 2x4 2x6 2x6 2x6 Level 4 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. Level 3 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. Level 2 1@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. 2@16"o.c. 1@16"o.c. 2@16"o.c. 1@16"o.c. 1@16"o.c. 1@16"o.c. Level 1 1@12"o.c. 1@16"o.c. 1@12"o.c. 1@16"o.c. 2@12"o.c. 1@16"o.c. 3@16"o.c. 1@12"o.c. 1@16"o.c. 1@16"o.c. SEE NOTE 'L' (WOOD WALL STUD SCHEDULE NOTES) AT DEMISING WALLS Clubhouse Stud Schedule (SPF No. 2) Exterior Walls Interior Bearing Walls 2x6 2x4 2x6 Level 1 1@16"o.c. 1@12"o.c. 1@16"o.c. Garages and Maintenance Building Stud Schedule (SPF No. 2) Exterior Walls Interior Bearing Walls 2x6 2x4 Level 1 1@16"o.c. 1@16"o.c. Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:16:46 PMS0.304 Stud / Post Schedule - Wood Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 11021102 A3 11081108 A2 11141114 B2 11161116 C1 11011101 A3 11071107 B1 11091109 A2 11131113 C1 11151115 A2 11121112 A1 11061106 A1 11051105 A1 11041104 A1 11031103 D.S. B0 11101110 A2-G2 11111111 D.S.D.S.D.S. D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S.D.S. D.S. D.S. D.S. D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S. D.S. UP 254' - 0" 254' - 0"73' - 3"73' - 3"2' - 8"40' - 1 1/2"26' - 1"4' - 4 1/2"2' - 8"40' - 1 1/2"26' - 1"4' - 4 1/2"12' - 0"18' - 7"57' - 10 1/2"70' - 9"61' - 10 1/2"18' - 7"12' - 0" 12' - 3"20' - 2"57' - 2 1/2"70' - 9"61' - 2 1/2"20' - 2"12' - 3" S3.100 .1_______ S3.100 .1_______ S3.100 .1_______ S3.100 .1_______ S3.100 .5_______ (TYP @ INT. GRADE BEAMS U.N.O.) S3.100 .6_______2' - 0"2' - 0"2' - 0"2' - 0"B/FTG @ BLDG #1 = 47'-0" (U.N.O.) (2) #5 X 5'-0" AT RE-ENTRANT CORNERS, TYP. PROVIDE 3/4" RECESS FOR SLIDING DOOR THRESHOLD, RE: ARCH FOR EXACT LOCATION (TYP. @ HATCHED AREAS) CONCRETE PATIO SLAB, DOWELS TO BE PROVIDED PER DETAIL 1A/S3.100 - RE: LANDSCAPE, TYP. FD SLOPERE: ARCHScale Date Drawn By Checked By Project Number 3/32" = 1'-0"3/18/2026 9:16:52 PMS1.110 Foundation Plan - Bldg #1-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Foundation Plan - Bldg #1-T01 - Overall • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS RESIDENTIAL FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 S.P.S.P. B2 31163116 B0 31083108 A1 31143114 A1 31123112 A3 31103110 A2 31043104 B2 31023102 C1 31153115 A1 31133113 A1 31113111 A3 31093109 B1 31073107 A2 31033103 C1 31013101 A2 31063106 A2-G2 31053105 D.S.D.S. D.S. D.S. D.S. D.S.D.S.D.S.D.S. D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S.D.S.D.S. D.S.D.S. D.S. 254' - 0"73' - 3"73' - 3"251' - 8"2' - 8"40' - 1 1/2"26' - 1"4' - 4 1/2"2' - 8"40' - 1 1/2"26' - 1"4' - 4 1/2"12' - 0"18' - 7"61' - 10 1/2"70' - 9"57' - 10 1/2"18' - 7"12' - 0" 12' - 3"20' - 2"61' - 2 1/2"70' - 9"57' - 2 1/2"20' - 2"12' - 3" S3.100 .6_______ S3.100 .5_______ (TYP @ INT. GRADE BEAMS U.N.O.) S3.100 .1_______ S3.100 .1_______ S3.100 .1_______ S3.100 .1_______2' - 0"2' - 0"2' - 0"2' - 0"B/FTG @ BLDG #3 = 47'-0" (U.N.O.) (2) #5 X 5'-0" AT RE-ENTRANT CORNERS, TYP. PROVIDE 3/4" RECESS FOR SLIDING DOOR THRESHOLD, RE: ARCH FOR EXACT LOCATION (TYP. @ HATCHED AREAS) CONCRETE PATIO SLAB, DOWELS TO BE PROVIDED PER DETAIL 1A/S3.100 - RE: LANDSCAPE, TYP. FD SLOPERE: ARCHScale Date Drawn By Checked By Project Number 3/32" = 1'-0"3/18/2026 9:16:56 PMS1.111 Foundation Plan - Bldg #3-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS RESIDENTIAL FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) 3/32" = 1'-0"1 Foundation Plan - Bldg #3-T01 - Overall No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 21152115 A1 21132113 A1 21112111 A3 21092109 A2 21072107 A2 21052105 A3 21032103 B2 21012101 B2 21022102 A2 21062106 A3 21042104 A1 21122112 A1 21142114 B2 21162116 B0 21102110 A2-G2 21082108 D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S.D.S. D.S. D.S. D.S.D.S. D.S.D.S. D.S. 242' - 3" 242' - 3"70' - 8"70' - 8"4' - 4 1/2"61' - 11"4' - 4 1/2"12' - 0"18' - 7"11' - 10 1/2"26' - 1"49' - 9"35' - 6"57' - 10 1/2"18' - 7"12' - 0"4' - 4 1/2"61' - 11"4' - 4 1/2"12' - 0"18' - 7"11' - 10 1/2"26' - 1"49' - 9"35' - 6"57' - 10 1/2"18' - 7"12' - 0" S3.100 .6_______ S3.100 .5_______ (TYP @ INT. GRADE BEAMS U.N.O.) S3.100 .1_______ S3.100 .1_______ S3.100 .1_______ S3.100 .1_______2' - 0"2' - 0"B/FTG @ BLDG #2 = 47'-0" (U.N.O.) B/FTG @ BLDG #4 = 48'-6" (U.N.O.) B/FTG @ BLDG #5 = 48'-6" (U.N.O.) (2) #5 X 5'-0" AT RE-ENTRANT CORNERS, TYP. PROVIDE 3/4" RECESS FOR SLIDING DOOR THRESHOLD, RE: ARCH FOR EXACT LOCATION (TYP. @ HATCHED AREAS) CONCRETE PATIO SLAB, DOWELS TO BE PROVIDED PER DETAIL 1A/S3.100 - RE: LANDSCAPE, TYP. FD SLOPERE: ARCHScale Date Drawn By Checked By Project Number 3/32" = 1'-0"3/18/2026 9:17:01 PMS1.120 Foundation Plan - Bldg #2,#4&#5-T02 - Overall Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Foundation Plan - Bldg #2,#4&#5-T02 - Overall • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS RESIDENTIAL / AMENITIES FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 11021102 A3 11081108 A2 11141114 B2 11161116 C1 11011101 A3 11071107 B1 11091109 A2 11131113 C1 11151115 A2 11121112 A1 11061106 A1 11051105 A1 11041104 A1 11031103 D.S. B0 11101110 A2-G2 11111111 D.S.D.S.D.S. D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S.D.S. D.S. D.S. D.S. D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S. D.S.3-2x8P3.5-116x12 P3.5-113-2x83-2x83-2x8 3-2x8 2-2x82-2x122-2x82-2x8 2-2x10 2-2x8 2-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x82-2x8 2-2x122-2x82-2x82-2x8 2-2x10 2-2x8 2-2x82-2x83-2x82-2x82-2x82-2x8 2-2x8 2-2x82-2x82-2x82-2x83-2x8 3-2x83-2x83-2x83-2x8 2-2x102-2x82-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x8 3-2x82-2x82-2x82-2x8 2-2x82-2x82-2x8 3-2x83-2x82-2x102-2x82-2x82-2x82-2x83-2x8P3.5-116x12 P3.5-11P5-9 P5-9 HUCQ210-3 HANGER HUCQ210-3 HANGER STS64 STS64 (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED PS3.5X9.25 PS3.5X9.25 W ECCQ CAP PS3.5X9.25 W ECCQ CAP (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS (1) KING (4) TRIMMERS (1) KING (4) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING STS64 STS64 (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED PS3.5X9.25 PS3.5X9.25 W ECCQ CAP PS3.5X9.25 W ECCQ CAP (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (4) TRIMMERS (1) KING (4) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING MIN. STS54 MIN. STS54 (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .1_______ S4.110 .1_______ S4.110 .2_______ S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .2_______ S4.110 .4_______ S4.110 .4_______ S4.110 .11_______ S4.110 .11_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ 3-2x8 3-2x8 3-2x12 3-2x12 3-2x8 3-2x8P5-18P3-14 P3-14P5-18P3-14 P3-14 2 SPAN2 SPAN(3) TRIMMERS (2) KING STS46 STS46 STS46 STS46 (3) TRIMMERS (2) KING GT TO BE DESIGNED FOR ADDITIONAL 1klf DL AND 1.4 klf LL FROM WALL ABOVE. CENTER GT UNDER 2x4 WALL ABOVE. GT TO BE DESIGNED FOR ADDITIONAL 1klf DL AND 1.4 klf LL FROM WALL ABOVE. CENTER GT UNDER 2x4 WALL ABOVE. S4.110 .3_______ (4) TRIMMERS (1) KING STS56 ECCQ CAP STS46 STS54 STS46 STS54 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 WOOD FLOOR FRAMING NOTES: 1. UNIT FLOOR FRAMING TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5PSF OF TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS LAYOUT SHALL BE COORDINATED TO AVOID CONFLICTS WITH MEP SYSTEMS. TRUSSES SHALL NOT BE PLACED DIRECTLY ABOVE OR BELOW ANY PARALLEL 2x6 WALLS TO PREVENT CONFLICTS WITH MEP ROUTING. 3. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 4. TRUSS SUPPLIER SHALL INCREASE SPACING OF TRUSSES AT LOCATIONS WHERE MECHANICAL ERV EQUIPMENTIS SPECIFIED. PROVIDE SUPPLEMENTAL LADDER FRAMING AS SHOWN IN DETAIL 6/S0.303 TO ACCOMMODATE INCREASED SPACING. REFER TO MECH DRAWINGS FOR SIZES AND LOCATIONS. 5. HEADERS SHALL BE AT TOP OF WINDOW OPENINGS AND DOOR OPENINGS. FLUSH BEAMS SHALL BE IN FLOOR CAVITY (TYP. U.N.O.) 6. SEE GENERAL NOTE WD2.0 ON SHEET S0.300 FOR MINIMUM QUANTITY OF STUDS AT BEARING ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES. SEE POST SCHEDULE FOR STUD AND POSTS SPECIFIED ON PLAN. 7. FLOOR AND ROOF SHEATHING SHALL BE OSB TYPICAL EXCEPT AT CORRIDORS AND EXPOSED/EXTERIOR AREAS WHICH SHALL BE C-D EXPOSURE 1 PLYWOOD. 8. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL (TYP) LEGEND: = EXTERIOR WOOD FRAMED STUD WALL = LOAD BEARING WOOD FRAMED STUD WALL = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD FRAMING SCHEDULE FRAMING TYPE (U.N.O. ON PLAN)LOCATION MAX SPACING (U.N.O. ON PLAN) FLOOR CORRIDOR ROOF 18" DEEP OPEN WEB WOOD TRUSSES 18" DEEP OPEN WEB WOOD TRUSSES 24" O.C. 24" O.C. 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES 24" O.C. NOTES: 1. BALCONY JOISTS TO BE SUPPORTED BY SIMPSON LUS210 HANGERS EACH END (TYP U.N.O. ON PLAN). 2. ALL FRAMING EXPOSED TO EXTERIOR ELEMENTS TO BE PRESSURE TREATED (EXCLUDING FRT AND ENGINEERED LUMBER). WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. G. PS3.5X9.25 = 3.5X9.25 PSL POST STS46 = (4) 2X6 STUDS STS56 = (5) 2X6 STUDS STS44 = (4) 2X4 STUDS STS54 = (5) 2X4 STUDS STS64 = (6) 2X4 STUDS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:17:14 PMS2.112 Wood Framing Plan - Level 2 - Bldg #1-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Wood Framing Plan - Level 2 - Bldg #1-T01 - Overall Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 2-2x10 (2) 2x10 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x12 (3) 2x12 6x12 6x12 P3-14 3 1/2 x 14 PSL P3.5-11 3 1/2 x 11 1/4 PSL P5-9 5 1/2 x 9 1/4 PSL P5-18 5 1/2 x 18 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 12021202 A1 12041204 A1 12061206 B1 12081208 B0 12101210 A2 12121212 B2 12161216 C1 12151215 A2-G2 12111211 B1 12091209 C1 12011201 A1 12051205 B1 12071207 A2 12131213 A2 12141214 A1 12031203 WOOD FLOOR FRAMING NOTES: 1. UNIT FLOOR FRAMING TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5PSF OF TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS LAYOUT SHALL BE COORDINATED TO AVOID CONFLICTS WITH MEP SYSTEMS. TRUSSES SHALL NOT BE PLACED DIRECTLY ABOVE OR BELOW ANY PARALLEL 2x6 WALLS TO PREVENT CONFLICTS WITH MEP ROUTING. 3. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 4. TRUSS SUPPLIER SHALL INCREASE SPACING OF TRUSSES AT LOCATIONS WHERE MECHANICAL ERV EQUIPMENTIS SPECIFIED. PROVIDE SUPPLEMENTAL LADDER FRAMING AS SHOWN IN DETAIL 6/S0.303 TO ACCOMMODATE INCREASED SPACING. REFER TO MECH DRAWINGS FOR SIZES AND LOCATIONS. 5. HEADERS SHALL BE AT TOP OF WINDOW OPENINGS AND DOOR OPENINGS. FLUSH BEAMS SHALL BE IN FLOOR CAVITY (TYP. U.N.O.) 6. SEE GENERAL NOTE WD2.0 ON SHEET S0.300 FOR MINIMUM QUANTITY OF STUDS AT BEARING ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES. SEE POST SCHEDULE FOR STUD AND POSTS SPECIFIED ON PLAN. 7. FLOOR AND ROOF SHEATHING SHALL BE OSB TYPICAL EXCEPT AT CORRIDORS AND EXPOSED/EXTERIOR AREAS WHICH SHALL BE C-D EXPOSURE 1 PLYWOOD. 8. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL (TYP) LEGEND: = EXTERIOR WOOD FRAMED STUD WALL = LOAD BEARING WOOD FRAMED STUD WALL = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD FRAMING SCHEDULE FRAMING TYPE (U.N.O. ON PLAN)LOCATION MAX SPACING (U.N.O. ON PLAN) FLOOR CORRIDOR ROOF 18" DEEP OPEN WEB WOOD TRUSSES 18" DEEP OPEN WEB WOOD TRUSSES 24" O.C. 24" O.C. 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES 24" O.C. NOTES: 1. BALCONY JOISTS TO BE SUPPORTED BY SIMPSON LUS210 HANGERS EACH END (TYP U.N.O. ON PLAN). 2. ALL FRAMING EXPOSED TO EXTERIOR ELEMENTS TO BE PRESSURE TREATED (EXCLUDING FRT AND ENGINEERED LUMBER).3-2x8P3.5-11P3.5-116x12 2-2x8 2-2x82-2x122-2x82-2x82-2x82-2x83-2x8 3-2x82-2x103-2x83-2x83-2x82-2x82-2x82-2x102-2x8 3-2x8 3-2x8 3-2x83-2x82-2x82-2x8 2-2x82-2x8 2-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x83-2x83-2x8 3-2x8 2-2x8 2-2x8 3-2x83-2x83-2x8 3-2x83-2x83-2x83-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x83-2x83-2x83-2x83-2x8 2-2x8 2-2x82-2x8 2-2x8 2-2x8 2-2x8 3-2x8 3-2x8 3-2x83-2x83-2x8P3.5-11P3.5-116x122-2x122-2x82-2x8 2-2x10 2-2x8 2-2x82-2x82-2x82-2x82-2x82-2x103-2x83-2x83-2x8 3-2x82-2x82-2x8HUCQ210-3 HANGER HUCQ210-3 HANGER LVL2-3:STS54 W/ CCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED(3) TRIMMERS (1) KING (3) TRIMMERS (1) KING LVL2-3: MIN STS44 LVL2-3: MIN STS44 (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS (1) SHARED KING LVL2-3: STS54 W/ ECCQ CAP FOR GT LVL2-3: STS54 W/ ECCQ CAP FOR GT LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING LVL4: STS44 LVL3: STS64 W/ ECCQ CAP S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .1_______ S4.110 .1_______ S4.110 .2_______ S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .2_______ S4.110 .4_______ S4.110 .4_______ S4.110 .11_______ S4.110 .11_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ 3-2x83-2x83-2x8 2-2x8 2-2x8 3-2x83-2x83-2x8 2-2x82-2x102-2x82-2x10S4.110 .3_______ (3) TRIMMERS (1) KING STS44 (3) TRIMMERS (1) KING STS44 LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. G. PS3.5X9.25 = 3.5X9.25 PSL POST STS46 = (4) 2X6 STUDS STS56 = (5) 2X6 STUDS STS44 = (4) 2X4 STUDS STS54 = (5) 2X4 STUDS STS64 = (6) 2X4 STUDS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:17:24 PMS2.113 Wood Framing Plan - Levels 3&4 - Bldg #1-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 2-2x10 (2) 2x10 2-2x12 (2) 2x12 3-2x8 (3) 2x8 6x12 6x12 P3.5-11 3 1/2 x 11 1/4 PSL 3/32" = 1'-0"1 Wood Framing Plan - Level 3&4 - Bldg #1-T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 31163116 B0 31083108 A1 31143114 A1 31123112 A3 31103110 A2 31043104 B2 31023102 C1 31153115 A1 31133113 A1 31113111 A3 31093109 B1 31073107 A2 31033103 C1 31013101 A2 31063106 A2-G2 31053105 D.S.D.S. D.S. D.S. D.S. D.S.D.S.D.S.D.S. D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S.D.S.D.S. D.S.D.S. D.S. WOOD FLOOR FRAMING NOTES: 1. UNIT FLOOR FRAMING TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5PSF OF TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS LAYOUT SHALL BE COORDINATED TO AVOID CONFLICTS WITH MEP SYSTEMS. TRUSSES SHALL NOT BE PLACED DIRECTLY ABOVE OR BELOW ANY PARALLEL 2x6 WALLS TO PREVENT CONFLICTS WITH MEP ROUTING. 3. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 4. TRUSS SUPPLIER SHALL INCREASE SPACING OF TRUSSES AT LOCATIONS WHERE MECHANICAL ERV EQUIPMENTIS SPECIFIED. PROVIDE SUPPLEMENTAL LADDER FRAMING AS SHOWN IN DETAIL 6/S0.303 TO ACCOMMODATE INCREASED SPACING. REFER TO MECH DRAWINGS FOR SIZES AND LOCATIONS. 5. HEADERS SHALL BE AT TOP OF WINDOW OPENINGS AND DOOR OPENINGS. FLUSH BEAMS SHALL BE IN FLOOR CAVITY (TYP. U.N.O.) 6. SEE GENERAL NOTE WD2.0 ON SHEET S0.300 FOR MINIMUM QUANTITY OF STUDS AT BEARING ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES. SEE POST SCHEDULE FOR STUD AND POSTS SPECIFIED ON PLAN. 7. FLOOR AND ROOF SHEATHING SHALL BE OSB TYPICAL EXCEPT AT CORRIDORS AND EXPOSED/EXTERIOR AREAS WHICH SHALL BE C-D EXPOSURE 1 PLYWOOD. 8. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL (TYP) LEGEND: = EXTERIOR WOOD FRAMED STUD WALL = LOAD BEARING WOOD FRAMED STUD WALL = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD FRAMING SCHEDULE FRAMING TYPE (U.N.O. ON PLAN)LOCATION MAX SPACING (U.N.O. ON PLAN) FLOOR CORRIDOR ROOF 18" DEEP OPEN WEB WOOD TRUSSES 18" DEEP OPEN WEB WOOD TRUSSES 24" O.C. 24" O.C. 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES 24" O.C. NOTES: 1. BALCONY JOISTS TO BE SUPPORTED BY SIMPSON LUS210 HANGERS EACH END (TYP U.N.O. ON PLAN). 2. ALL FRAMING EXPOSED TO EXTERIOR ELEMENTS TO BE PRESSURE TREATED (EXCLUDING FRT AND ENGINEERED LUMBER).3-2x83-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x83-2x83-2x8 3-2x8 3-2x83-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x8P3.5-116x12 P3.5-11P3.5-116x12 P3.5-112-2x122-2x82-2x8 2-2x10 2-2x8 2-2x82-2x102-2x82-2x82-2x82-2x82-2x82-2x8 2-2x8 P5-9 P5-9 2-2x8 2-2x8 2-2x82-2x83-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x102-2x82-2x82-2x82-2x82-2x122-2x82-2x8 2-2x10 2-2x8 2-2x82-2x8 HUCQ210-3 HANGER HUCQ210-3 HANGER STS64 STS64 (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED PS3.5X9.25 PS3.5X9.25 W ECCQ CAP PS3.5X9.25 W ECCQ CAP (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED(4) TRIMMERS (1) KING (4) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING STS64 STS64 (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED PS3.5X9.25 PS3.5X9.25 W ECCQ CAP PS3.5X9.25 W ECCQ CAP (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (4) TRIMMERS (1) KING (4) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING MIN. STS54 MIN. STS54 (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .1_______ S4.110 .1_______ S4.110 .2_______ S4.110 .1_______ S4.110 .2_______S4.110 .2_______ S4.110 .2_______ S4.110 .4_______ S4.110 .4_______ S4.110 .11_______ S4.110 .11_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ 3-2x8 3-2x8 3-2x12 3-2x8 3-2x8 3-2x12 P5-18P3-14 P3-14 P3-14 P5-18P3-14 2 SPAN2 SPAN(4) TRIMMERS (1) KING STS56 ECCQ CAP (3) TRIMMERS (2) KING STS46 STS46 GT TO BE DESIGNED FOR ADDITIONAL 1klf DL AND 1.4 klf LL FROM WALL ABOVE. CENTER GT UNDER 2x4 WALL ABOVE. STS46 STS46 (3) TRIMMERS (2) KING GT TO BE DESIGNED FOR ADDITIONAL 1klf DL AND 1.4 klf LL FROM WALL ABOVE. CENTER GT UNDER 2x4 WALL ABOVE. S4.110 .3_______ STS46 STS54 STS46 STS54 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. G. PS3.5X9.25 = 3.5X9.25 PSL POST STS46 = (4) 2X6 STUDS STS56 = (5) 2X6 STUDS STS44 = (4) 2X4 STUDS STS54 = (5) 2X4 STUDS STS64 = (6) 2X4 STUDS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:17:34 PMS2.122 Wood Framing Plan - Level 2 - Bldg #3-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 2-2x10 (2) 2x10 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x12 (3) 2x12 6x12 6x12 P3-14 3 1/2 x 14 PSL P3.5-11 3 1/2 x 11 1/4 PSL P5-9 5 1/2 x 9 1/4 PSL P5-18 5 1/2 x 18 PSL 3/32" = 1'-0"1 Wood Framing Plan - Level 2 - Bldg #3-T01 - Overall No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 A2-G2 32053205 A2 32033203 C1 32013201 B2 32023202 A2 32043204 A2 32063206 B0 32083208 B1 32103210 A1 32123212 A1 32143214 B2 32163216 B1 32073207 B1 32093209 A1 32113211 A1 32133213 C1 32153215 WOOD FLOOR FRAMING NOTES: 1. UNIT FLOOR FRAMING TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5PSF OF TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS LAYOUT SHALL BE COORDINATED TO AVOID CONFLICTS WITH MEP SYSTEMS. TRUSSES SHALL NOT BE PLACED DIRECTLY ABOVE OR BELOW ANY PARALLEL 2x6 WALLS TO PREVENT CONFLICTS WITH MEP ROUTING. 3. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 4. TRUSS SUPPLIER SHALL INCREASE SPACING OF TRUSSES AT LOCATIONS WHERE MECHANICAL ERV EQUIPMENTIS SPECIFIED. PROVIDE SUPPLEMENTAL LADDER FRAMING AS SHOWN IN DETAIL 6/S0.303 TO ACCOMMODATE INCREASED SPACING. REFER TO MECH DRAWINGS FOR SIZES AND LOCATIONS. 5. HEADERS SHALL BE AT TOP OF WINDOW OPENINGS AND DOOR OPENINGS. FLUSH BEAMS SHALL BE IN FLOOR CAVITY (TYP. U.N.O.) 6. SEE GENERAL NOTE WD2.0 ON SHEET S0.300 FOR MINIMUM QUANTITY OF STUDS AT BEARING ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES. SEE POST SCHEDULE FOR STUD AND POSTS SPECIFIED ON PLAN. 7. FLOOR AND ROOF SHEATHING SHALL BE OSB TYPICAL EXCEPT AT CORRIDORS AND EXPOSED/EXTERIOR AREAS WHICH SHALL BE C-D EXPOSURE 1 PLYWOOD. 8. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL (TYP) LEGEND: = EXTERIOR WOOD FRAMED STUD WALL = LOAD BEARING WOOD FRAMED STUD WALL = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD FRAMING SCHEDULE FRAMING TYPE (U.N.O. ON PLAN)LOCATION MAX SPACING (U.N.O. ON PLAN) FLOOR CORRIDOR ROOF 18" DEEP OPEN WEB WOOD TRUSSES 18" DEEP OPEN WEB WOOD TRUSSES 24" O.C. 24" O.C. 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES 24" O.C. NOTES: 1. BALCONY JOISTS TO BE SUPPORTED BY SIMPSON LUS210 HANGERS EACH END (TYP U.N.O. ON PLAN). 2. ALL FRAMING EXPOSED TO EXTERIOR ELEMENTS TO BE PRESSURE TREATED (EXCLUDING FRT AND ENGINEERED LUMBER).3-2x83-2x83-2x8 3-2x8 3-2x82-2x82-2x122-2x8 2-2x82-2x102-2x8 2-2x83-2x8P3.5-116x12 P3.5-112-2x8 2-2x82-2x82-2x82-2x82-2x103-2x8 3-2x8 3-2x83-2x83-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x8P3.5-116x12 P3.5-112-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 3-2x8 2-2x8 2-2x82-2x8 2-2x8 2-2x8 2-2x8 2-2x122-2x82-2x8 2-2x10 2-2x8 2-2x83-2x83-2x82-2x82-2x82-2x82-2x82-2x103-2x83-2x83-2x8 3-2x8 3-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 2-2x82-2x8HUCQ210-3 HANGER HUCQ210-3 HANGER LVL2-3:STS54 W/ CCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED(3) TRIMMERS (1) KING (3) TRIMMERS (1) KING MIN. STS54 MIN. STS54 (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL2-3: STS54 W/ ECCQ CAP FOR GT LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS (1) KING (3) TRIMMERS (1) KING LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL3-4: STS44 LVL2-3: STS64 W/ ECCQ CAP S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .1_______ S4.110 .1_______ S4.110 .2_______ S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .2_______ S4.110 .4_______ S4.110 .4_______ S4.110 .11_______ S4.110 .11_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ 2-2x8 3-2x8 3-2x8 3-2x82-2x102-2x83-2x83-2x83-2x8 2-2x8 2-2x82-2x10S4.110 .3_______ (3) TRIMMERS (1) KING STS44 (3) TRIMMERS (1) KING STS44 WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. G. PS3.5X9.25 = 3.5X9.25 PSL POST STS46 = (4) 2X6 STUDS STS56 = (5) 2X6 STUDS STS44 = (4) 2X4 STUDS STS54 = (5) 2X4 STUDS STS64 = (6) 2X4 STUDS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:17:43 PMS2.123 Wood Framing Plan - Levels 3&4 - Bldg #3-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 2-2x10 (2) 2x10 2-2x12 (2) 2x12 3-2x8 (3) 2x8 6x12 6x12 P3.5-11 3 1/2 x 11 1/4 PSL 3/32" = 1'-0"1 Wood Framing Plan - Level 3&4 - Bldg #3-T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 21152115 A1 21132113 A1 21112111 A3 21092109 A2 21072107 A2 21052105 A3 21032103 B2 21012101 B2 21022102 A2 21062106 A3 21042104 A1 21122112 A1 21142114 B2 21162116 B0 21102110 A2-G2 21082108 D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S.D.S. D.S. D.S. D.S.D.S. D.S.D.S. D.S.3-2x83-2x83-2x8 3-2x8 3-2x82-2x82-2x122-2x8 2-2x82-2x102-2x8 2-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x8 3-2x8 3-2x83-2x8P5-113-2x83-2x83-2x8 3-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x8P5-11P3.5-11P3.5-116x12 2-2x8 2-2x82-2x8 2-2x82-2x8 2-2x8 P5-9 3-2x8 2-2x82-2x8 2-2x8 3-2x12 3-2x12 2-2x8 2-2x8 2-2x8 2-2x8 2-2x10 2-2x82-2x82-2x82-2x122-2x82-2x122-2x82-2x82-2x102-2x8 P3.5-116x12 P3.5-112-2x82-2x102-2x82-2x82-2x122-2x8HUCQ210-3 HANGER HUCQ210-3 HANGER STS64 STS64 (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED MIN. STS54 MIN. STS54 PS3.5X9.25 PS3.5X9.25 W ECCQ CAP PS3.5X9.25 W ECCQ CAP PS3.5X9.25 CCQ CAP (3) TRIMMERS @ EACH BEAM. (1) KING SHARED STS64 W/ CCQ CAP STS64 W/ ECCQ CAP FOR GT STS64 STS64 (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED (3) TRIMMERS @ EACH BEAM. (1) KING SHARED PS3.5X9.25 PS3.5X9.25 W ECCQ CAP PS3.5X9.25 W ECCQ CAP PS3.5X9.25 CCQ CAP (3) TRIMMERS @ EACH BEAM. (1) KING SHARED STS64 W/ CCQ CAP STS64 W/ ECCQ CAP FOR GT S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .1_______ S4.110 .1_______ S4.110 .2_______ S4.110 .1_______ S4.110 .2_______S4.110 .2_______ S4.110 .2_______ S4.110 .4_______ S4.110 .4_______ S4.110 .11_______ S4.110 .11_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______2 SPAN3-2x83-2x8 3-2x12 P5-18P3-14P3-14 P3-14GT (3) TRIMMERS (2) KING STS46 STS46 GT TO BE DESIGNED FOR ADDITIONAL 1klf DL AND 1.4 klf LL FROM WALL ABOVE. (4) TRIMMERS (1) KING STS56 ECCQ CAP STS54 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 CANT. WOOD CANOPY -SEE DETAIL /9 S4.110 WOOD FLOOR FRAMING NOTES: 1. UNIT FLOOR FRAMING TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5PSF OF TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS LAYOUT SHALL BE COORDINATED TO AVOID CONFLICTS WITH MEP SYSTEMS. TRUSSES SHALL NOT BE PLACED DIRECTLY ABOVE OR BELOW ANY PARALLEL 2x6 WALLS TO PREVENT CONFLICTS WITH MEP ROUTING. 3. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 4. TRUSS SUPPLIER SHALL INCREASE SPACING OF TRUSSES AT LOCATIONS WHERE MECHANICAL ERV EQUIPMENTIS SPECIFIED. PROVIDE SUPPLEMENTAL LADDER FRAMING AS SHOWN IN DETAIL 6/S0.303 TO ACCOMMODATE INCREASED SPACING. REFER TO MECH DRAWINGS FOR SIZES AND LOCATIONS. 5. HEADERS SHALL BE AT TOP OF WINDOW OPENINGS AND DOOR OPENINGS. FLUSH BEAMS SHALL BE IN FLOOR CAVITY (TYP. U.N.O.) 6. SEE GENERAL NOTE WD2.0 ON SHEET S0.300 FOR MINIMUM QUANTITY OF STUDS AT BEARING ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES. SEE POST SCHEDULE FOR STUD AND POSTS SPECIFIED ON PLAN. 7. FLOOR AND ROOF SHEATHING SHALL BE OSB TYPICAL EXCEPT AT CORRIDORS AND EXPOSED/EXTERIOR AREAS WHICH SHALL BE C-D EXPOSURE 1 PLYWOOD. 8. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL (TYP) LEGEND: = EXTERIOR WOOD FRAMED STUD WALL = LOAD BEARING WOOD FRAMED STUD WALL = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD FRAMING SCHEDULE FRAMING TYPE (U.N.O. ON PLAN)LOCATION MAX SPACING (U.N.O. ON PLAN) FLOOR CORRIDOR ROOF 18" DEEP OPEN WEB WOOD TRUSSES 18" DEEP OPEN WEB WOOD TRUSSES 24" O.C. 24" O.C. 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES 24" O.C. NOTES: 1. BALCONY JOISTS TO BE SUPPORTED BY SIMPSON LUS210 HANGERS EACH END (TYP U.N.O. ON PLAN). 2. ALL FRAMING EXPOSED TO EXTERIOR ELEMENTS TO BE PRESSURE TREATED (EXCLUDING FRT AND ENGINEERED LUMBER). WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. G. PS3.5X9.25 = 3.5X9.25 PSL POST STS46 = (4) 2X6 STUDS STS56 = (5) 2X6 STUDS STS44 = (4) 2X4 STUDS STS54 = (5) 2X4 STUDS STS64 = (6) 2X4 STUDS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:17:54 PMS2.132 Wood Framing Plan - Level 2 - Bldg T02 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Wood Framing Plan - Level 2 - Bldg T02 - Overall Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 2-2x10 (2) 2x10 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x12 (3) 2x12 6x12 6x12 P3-14 3 1/2 x 14 PSL P3.5-11 3 1/2 x 11 1/4 PSL P5-9 5 1/2 x 9 1/4 PSL P5-11 5 1/2 x 11 1/4 PSL P5-18 5 1/2 x 18 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 22022202 B2 22162216 B2 22152215 B0 22102210 B2 22012201 A2 22072207 A2 22052205 A3 22032203 A3 22042204 A2 22062206 A2-G2 22082208 A1 22122212 A1 22112211 A1 22132213 A1 22142214 B1-G2 22092209 WOOD FLOOR FRAMING NOTES: 1. UNIT FLOOR FRAMING TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5PSF OF TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS LAYOUT SHALL BE COORDINATED TO AVOID CONFLICTS WITH MEP SYSTEMS. TRUSSES SHALL NOT BE PLACED DIRECTLY ABOVE OR BELOW ANY PARALLEL 2x6 WALLS TO PREVENT CONFLICTS WITH MEP ROUTING. 3. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 4. TRUSS SUPPLIER SHALL INCREASE SPACING OF TRUSSES AT LOCATIONS WHERE MECHANICAL ERV EQUIPMENTIS SPECIFIED. PROVIDE SUPPLEMENTAL LADDER FRAMING AS SHOWN IN DETAIL 6/S0.303 TO ACCOMMODATE INCREASED SPACING. REFER TO MECH DRAWINGS FOR SIZES AND LOCATIONS. 5. HEADERS SHALL BE AT TOP OF WINDOW OPENINGS AND DOOR OPENINGS. FLUSH BEAMS SHALL BE IN FLOOR CAVITY (TYP. U.N.O.) 6. SEE GENERAL NOTE WD2.0 ON SHEET S0.300 FOR MINIMUM QUANTITY OF STUDS AT BEARING ENDS OF ALL BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES. SEE POST SCHEDULE FOR STUD AND POSTS SPECIFIED ON PLAN. 7. FLOOR AND ROOF SHEATHING SHALL BE OSB TYPICAL EXCEPT AT CORRIDORS AND EXPOSED/EXTERIOR AREAS WHICH SHALL BE C-D EXPOSURE 1 PLYWOOD. 8. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL (TYP) LEGEND: = EXTERIOR WOOD FRAMED STUD WALL = LOAD BEARING WOOD FRAMED STUD WALL = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD FRAMING SCHEDULE FRAMING TYPE (U.N.O. ON PLAN)LOCATION MAX SPACING (U.N.O. ON PLAN) FLOOR CORRIDOR ROOF 18" DEEP OPEN WEB WOOD TRUSSES 18" DEEP OPEN WEB WOOD TRUSSES 24" O.C. 24" O.C. 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES 24" O.C. NOTES: 1. BALCONY JOISTS TO BE SUPPORTED BY SIMPSON LUS210 HANGERS EACH END (TYP U.N.O. ON PLAN). 2. ALL FRAMING EXPOSED TO EXTERIOR ELEMENTS TO BE PRESSURE TREATED (EXCLUDING FRT AND ENGINEERED LUMBER).3-2x83-2x83-2x8 3-2x8 3-2x82-2x82-2x122-2x82-2x82-2x8 2-2x10 2-2x8 3-2x8P3.5-113-2x12 P3.5-112-2x8 2-2x122-2x82-2x82-2x8 2-2x10 2-2x83-2x83-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x8 3-2x8 3-2x83-2x82-2x8 2-2x122-2x82-2x8 2-2x10 2-2x8 2-2x8P3.5-113-2x12 P3.5-113-2x82-2x8 2-2x122-2x82-2x8 2-2x10 2-2x82-2x83-2x83-2x83-2x8 3-2x8 3-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x83-2x82-2x8 2-2x82-2x8 2-2x83-2x12 3-2x12 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 HUCQ210-3 HANGER HUCQ210-3 HANGER LVL2-3: MIN STS44 LVL2-3: MIN STS44 LVL2-3:STS54 W/ CCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL2-3: STS54 W/ ECCQ CAP FOR GT LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL2-3:STS54 W/ CCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL2-3: STS54 W/ ECCQ CAP FOR GT LVL2-3:STS54 W/ CCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL2-3: STS54 W/ ECCQ CAP FOR GT LVL4: STS44 LVL3: STS64 W/ ECCQ CAP LVL2-3:STS54 W/ CCQ CAP LVL2-3: (3) TRIMMERS @ EACH BEAM. (1) KING SHARED LVL3-4: STS44 LVL2-3: STS64 W/ CCQ CAP LVL2-3: STS54 W/ ECCQ CAP FOR GT S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .1_______ S4.110 .1_______ S4.110 .2_______ S4.110 .1_______ S4.110 .2_______ S4.110 .2_______ S4.110 .2_______ S4.110 .4_______ S4.110 .4_______ S4.110 .11_______ S4.110 .11_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ S4.110 .6_______ 2-2x8 3-2x8 3-2x8 3-2x82-2x102-2x8STS44 (3) TRIMMERS (1) KING WOOD POST SCHEDULE NOTES: A. WHERE POSTS OR STUDPACKS ARE NOT SPECIFIED ON PLAN AT ANY BEARING SUPPORT OF BEAMS, HEADERS (DROP BEAMS), FLUSH BEAMS, AND GIRDER TRUSSES, SEE WOOD FRAMING GENERAL NOTE B THROUGH D FOR MINIMUM SUPPORT MEMBERS REQUIRED. B. WHERE STUDPACK WIDTHS ARE NOT SPECIFIED, PROVIDE STUD SIZE TO FIT WITHIN ENTIRE WALL CAVITY (IE: PROVIDE 2X6 STUDS AT 6" NOMINAL WALL WIDTHS). C. POST CAPS AND BASES SHALL BE SIMPSON OR APPROVED EQUAL WITH STRAPS ROTATED AS NEEDED BASED ON POST ORIENTATION. D. ALL POSTS THAT ARE NOT WITHIN WALL ASSEMBLY SHALL HAVE APPROPRIATE POST CAP AND BASE, TYPICAL. UNO PROVIDE ABU TYPE BASE AT SUPPORT SLAB AND BC TYPE CAP AND BASE AT FRAMING LEVELS. E. POSTS AND STUDPACKS SHALL BE CONTINUOUS LEVEL BY LEVEL DOWN TO SUPPORTING SLAB WITH SQUASH BLOCKS INSTALLED AT ALL FLOOR/ROOF CAVITIES COMPOSED OF EQUAL SIZE AND MATERIALS TO ENSURE LOAD PATH CONTINUITY. F. REFER TO ARCHITECTURAL DRAWINGS FOR ALL FIRE PROTECTION REQUIREMENTS, TYPICAL. G. PS3.5X9.25 = 3.5X9.25 PSL POST STS46 = (4) 2X6 STUDS STS56 = (5) 2X6 STUDS STS44 = (4) 2X4 STUDS STS54 = (5) 2X4 STUDS STS64 = (6) 2X4 STUDS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:04 PMS2.133 Wood Framing Plan - Levels 3&4 - Bldg T02 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 2-2x10 (2) 2x10 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x12 (3) 2x12 P3.5-11 3 1/2 x 11 1/4 PSL 3/32" = 1'-0"1 Wood Framing Plan - Level 3&4 - Bldg T02 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 14021402 A2 14131413 A2 14111411 A2 14141414 A2 14121412 A1 14061406 A1 14041404 B2 14161416 A1 14031403 A1 14051405 B0 14101410 B1 14091409 B1 14071407 B1 14081408 C1-G2 14011401 C1 14151415 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL).3-2x83-2x10 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x8 3-2x8 3-2x10 3-2x83-2x83-2x83-2x83-2x83-2x10 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x10 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x83-2x82-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x12 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 S4.310 .2_______ S4.310 .1_______ S4.310 .2_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .2_______ S4.310 .2_______ S4.310 .4_______ S4.310 .8_______ S4.310 .8_______ S4.310 .8_______ SIM SIMSIM SIM W8X15 LIFELINE BEAM W8X15 HOIST BEAM S4.311 2_______ S4.311 1_______GTGT8' - 9 1 / 2 " 2x6 ROOF JOISTS @ 12" O.C.GTS2.210 2 . S4.310 .7_______ S4.311 1_______3-2x12GT -SEE ROOF FRAMING PLAN 8' - 9 1/2"8' - 9 1/2"2x12 JOISTS @ 24" O.C. ROOF ACCESS OPENING - RE: ARCH FOR EXACT SIZE & LOCATION Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:13 PMS2.210 Wood Framing Plan - Roof - Bldg #1-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Wood Beam Schedule Mark Beam / Header W8X15 2-2x8 (2) 2x8 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x10 (3) 2x10 3-2x12 (3) 2x12 3/32" = 1'-0"1 Wood Framing Plan - Roof - Bldg #1-T01 3/32" = 1'-0"2 Wood Framing Plan - Roof Access Platform No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 34163416 C1 34153415 A2 34033403 A2 34053405 A2 34043404 A2 34063406 A1 34123412 A1 34143414 B2 34023402 A1 34133413 A1 34113411 C1 34013401 B0 34083408 B1 34073407 B1 34093409 B1 34103410 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL).3-2x83-2x83-2x10 3-2x8 3-2x8 3-2x83-2x103-2x83-2x83-2x8 2-2x8 2-2x82-2x8 2-2x8 2-2x8 2-2x82-2x122-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x82-2x8 2-2x8 2-2x8 2-2x8 3-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x83-2x83-2x8 3-2x83-2x83-2x83-2x83-2x8 3-2x8 3-2x10 3-2x83-2x83-2x83-2x83-2x10 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x8 S4.310 .2_______ S4.310 .1_______ S4.310 .2_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .2_______ S4.310 .2_______ S4.310 .8_______ S4.310 .8_______ S4.310 .8_______ S4.310 .4_______ SIM W8X15 LIFELINE BEAM W8X15 HOIST BEAM S4.311 1_______ S4.311 2_______GTGTGT2x6 ROOF JOISTS @ 12" O.C.8' - 9 1/2"S2.210 2 . S4.310 .7_______ Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:20 PMS2.211 Wood Framing Plan - Roof - Bldg #3-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 Wood Beam Schedule Mark Beam / Header W8X18 2-2x8 (2) 2x8 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x10 (3) 2x10 3/32" = 1'-0"1 Wood Framing Plan - Roof - Bldg #3-T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 24012401 A3 24032403 A2 24052405 A2 24072407 A1 24112411 A1 24132413 B2 24152415 B2 24162416 A1 24142414 A1 24122412 B0 24102410 A2 24082408 A2 24062406 A3 24042404 B2 24022402 B1-G2 24092409 3-2x10 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x10 3-2x8 3-2x83-2x83-2x83-2x83-2x83-2x10 3-2x83-2x8 3-2x8 3-2x8 3-2x83-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x8 3-2x83-2x8 3-2x103-2x83-2x83-2x83-2x83-2x82-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x12 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 2-2x8 3-2x8 S4.310 .2_______ S4.310 .1_______ S4.310 .2_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .2_______ S4.310 .2_______ S4.310 .8_______ S4.310 .8_______ S4.310 .8_______ 3-2x8 3-2x8 3-2x8 2-2x8 S4.310 .4_______ SIM W8X15 LIFELINE BEAM W8X15 HOIST BEAM S4.311 2_______ S4.311 1_______GTGTGT2x6 ROOF JOISTS @ 12" O.C.8' - 9 1/2"S2.210 2 . S4.310 .7_______ WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL). Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:28 PMS2.220 Wood Framing Plan - Roof - Bldg T02 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Wood Framing Plan - Roof - Bldg T02 Wood Beam Schedule Mark Beam / Header W8X18 2-2x8 (2) 2x8 2-2x12 (2) 2x12 3-2x8 (3) 2x8 3-2x10 (3) 2x10 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 11021102 A3 11081108 A2 11141114 B2 11161116 C1 11011101 A3 11071107 B1 11091109 A2 11131113 C1 11151115 A2 11121112 A1 11061106 A1 11051105 A1 11041104 A1 11031103 D.S. B0 11101110 A2-G2 11111111 D.S.D.S.D.S. D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S.D.S. D.S. D.S. D.S. D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S. D.S. UP WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414. WSW-5 WSW-4WSW-6WSW-6WSW-5WSW-5WSW-5 WSW-5WSW-6WSW-6WSW-4WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-4WSW-5WSW-6WSW-6WSW-5WSW-5WSW-6WSW-6WSW-4WSW-5 WSW-5 WSW-5 WSW-5 SHEARWALL DIAGRAM - 4 STORY WSW-4 WSW-5 WSW-6 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 C ATR 3/4 ATUD 6-2 1 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B D ATR 5/8 ATUD 6-2 D ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B C ATR 5/8 ATUD 6-2 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:30 PMS2.410 Wood Shearwall Plan - Bldg #1-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Wood Shearwall Plan - Level 2 - Bldg #1-T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 31163116 B0 31083108 A1 31143114 A1 31123112 A3 31103110 A2 31043104 B2 31023102 C1 31153115 A1 31133113 A1 31113111 A3 31093109 B1 31073107 A2 31033103 C1 31013101 A2 31063106 A2-G2 31053105 D.S.D.S. D.S. D.S. D.S. D.S.D.S.D.S.D.S. D.S.D.S.D.S. D.S.D.S.D.S.D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S.D.S.D.S. D.S.D.S. D.S. WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414. WSW-5 WSW-4WSW-6WSW-6WSW-5WSW-5WSW-5 WSW-5WSW-6WSW-6WSW-4WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-5 WSW-4WSW-5WSW-6WSW-6WSW-5WSW-5WSW-6WSW-6WSW-4WSW-5WSW-5 WSW-5 WSW-5 SHEARWALL DIAGRAM - 4 STORY WSW-4 WSW-5 WSW-6 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 C ATR 3/4 ATUD 6-2 1 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B D ATR 5/8 ATUD 6-2 D ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B C ATR 5/8 ATUD 6-2 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:34 PMS2.411 Wood Shearwall Plan - Bldg #3-T01 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Wood Shearwall Plan - Level 2 - Bldg #3-T01 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 B2 21152115 A1 21132113 A1 21112111 A3 21092109 A2 21072107 A2 21052105 A3 21032103 B2 21012101 B2 21022102 A2 21062106 A3 21042104 A1 21122112 A1 21142114 B2 21162116 B0 21102110 A2-G2 21082108 D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S. D.S. D.S. D.S. D.S. D.S.D.S. D.S.D.S. D.S. D.S. D.S.D.S. D.S.D.S. D.S. WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414. WSW-5 WSW-4WSW-6WSW-5WSW-5WSW-5 WSW-5WSW-6WSW-6WSW-4WSW-5 WSW-5 WSW-5 WSW-5WSW-5 WSW-5 WSW-5 WSW-4WSW-5WSW-6WSW-6WSW-5WSW-5WSW-6WSW-4WSW-5WSW-5 WSW-5 WSW-5 WSW-5 WSW-6WSW-6SHEARWALL DIAGRAM - 4 STORY WSW-4 WSW-5 WSW-6 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 C ATR 3/4 ATUD 6-2 1 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B D ATR 5/8 ATUD 6-2 D ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B C ATR 5/8 ATUD 6-2 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:40 PMS2.420 Wood Shearwall Plan - Bldg T02 - Overall Plan Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/32" = 1'-0"1 Wood Shearwall Plan - Level 2 - Bldg T02 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 FIRST POUR SECOND POUR FIRST POUR SECOND POUR24 BAR DIAMETER( 2' - 0" MIN.)24 BAR DIAMETER ( 2' - 0" MIN.) 24 BAR DIAMETER ( 2' - 0" MIN.)24 BAR DIAMETER( 2' - 0" MIN.)DOWELS TO MATCH CONTINUOUS HORIZONTAL BEAM REINFORCEMENT SIZE AND SPACING OF INTERSECTING GRADE BEAM CONTINUOUS HORIZONTAL BEAM REINFORCEMENT 24 BAR DIAMETER( 2' - 0" MIN.)24 BAR DIAMETER ( 2' - 0" MIN.) DOWELS TO MATCH CONTINUOUS HORIZONTAL BEAM REINFORCEMENT SIZE AND SPACING 24 BAR DIAMETER( 2' - 0" MIN.)24 BAR DIAMETER ( 2' - 0" MIN.) CONTINUOUS HORIZONTAL BEAM REINFORCEMENT STD. 90⌀HOOK STD. 90⌀HOOK 2' - 0"6" A SECTION A 6"2' - 0" CONTINUOUS FORMED KEYWAY TOP OF CONCRETE PROVIDE SLIP TUPE OR WRAP CONSTRUCTION JOINT DOWELS AT SECOND POUR TYPICAL SLAB REINF - CHAIR INDEPENDENTLY FROM CONSTRCTION JOINT DOWELS STAGGER DOWELS AS INDICATED NOTE: 1. CONTRACTOR TO SUBMIT CONSTRUCTION JOINT LAYOUT TO EOR FOR APPROVAL. 2. DOWELS SHALL BE PLACED PERPENDICULAR TO FACE OF SLAB AT CONSTRUCTION JOINT TO ALLOW FOR SLIPPAGE DURING SHRINKAGE. 1' - 6"SLAB STEP (H)SLAB STEP (H)1' - 0"1' - 6" SLAB ON GRADE REINF -SEE PLAN SLAB ON GRADE REINF -SEE PLAN (2) #5 CONT "Z" BAR W/ STD. 90° HOOKS TO MATCH SLAB REINF. SIZE AND SPACINGSLAB STEP (H)1' - 0"1' - 6" SLAB ON GRADE REINF -SEE PLAN (2) #5 CONT "Z" BAR W/ STD. 90° HOOKS TO MATCH SLAB REINF. SIZE AND SPACING #4 FACE BARS @ 12" O.C. SLAB STEP (H ≤6") SLAB STEP (H > 6" / H ≤1'-0") SLAB STEP (H > 1'-0" / H ≤2'-6") 1/4" WIDE CONTROL JOINT 1 TOP OF CONCRETESLAB REINF -SEE PLAN NOTE: 1. AT CONTRATORS OPTION, CONTROL JOINT MAY BE: • PRE-FORMED ZIP-STRIP OR EQUAL -PRE-FORMED CONTROL JOINTS TO BE INSTALLED IN FRESH CONCRETE PER MANUFACTURERS RECOMENDATIONS. • SAW CUT -JOINTS TO BE CUT INTO SLAB AS SOON AS SLAB IS HARDENED ENOUGH TO SUPPORT THE WEIGHT OF SAWING EQUIPMENT WITHOUT DAMAGING SLAB (APPROXIMATLY 4 TO 8 HOURS AFTER PLACEMENT). 2. CLEAN CONTROL JOINTS TO ENSURE JOINT IS CLEAR OF ALL LOOSE DEBRIS PRIOR TOP FILLING THE JOINTS. THK (D)SLABCONTROL JOINT 0.25 DPROVIDE BACKER ROD / CAULK 2DEPTH (d)GRADE BEAM(WICHEVER IS GREATER) 2' - 0" OR STEP DEPTHSTEP DEPTH (s)DEPTH (d)GRADE BEAM1 1 LAP SPLICE = ℓd EMBEDMENT = ℓd LAP SPLICE = ℓd ADDITIONAL REINFORCEMENT AT GRADE BEAM SOFFIT TO MATCH CONTINUOUS GRADE BEAM BOTTOM REINFORCEMENT ADDITIONAL BARS AT FACE OF GRADE BEAM STEP TO MATCH CONTINUOUS GRADE BEAM TOP BAR SIZE & QUANTITY W/ STD. 90° HOOKS TOP AND BOTT. 3" NOTE: 1. IF STEP IS GREATER THAN BEAM DEPTH, PROVIDE MULTIPLE EQUAL STEPS IN GRADE BEAM MIN 3 GRADE BEAM DEPTH'S APART.(STEP DEPTH NOT TO EXCEED GRADE BEAM DEPTH 1)CONTINUOUS GRADE BEAM TOP REINFORCEMENT CONTINUOUS GRADE BEAM BOTTOM REINFORCEMENT - EXTEND BOTTOM BAR TO FACE OF STEP GRADE BEAM STIRRUPS PER GRADE BEAM DETAILS GRADE BEAM STIRRUPS PER GRADE BEAM DETAILS FULL DEPTH GRADE BEAM STIRRUPS TO MATCH SIZE AND SPACING FROM GRADE BEAM DETAILS (W) GRADE BEAM WIDTH GRADE BEAM DEPTH (D)EQEQEQEQEQDESIGN GRADE BEAM TOP BARS DESIGN GRADE BEAM BOTT BARS SCHEDULED ADDITIONAL FACE BARS FACE BAR SCHEDULE GRADE BEAM DEPTH (D) D < 36" 36" ≤D < 42" 42" ≤D < 48" ADDITIONAL FACE BARS (EA FACE) NONE (3) #4 (4) #4 48" ≤D ≤54" (5) #4 DESIGN GRADE BEAM STIRRUPS PIPE -RE: PLUMBING SLAB ON GRADE - SEE PLAN SEE PLAN AND GRADE BEAM DETAIL FOR INFORMATION NOT SHOWN 1' - 6"GRADE BEAM WIDTH 1' - 6" 1 1 1 1 THERE SHALL BE NO PLUMBING LINES RUNNING PARALLEL TO OR WITHIN ANY FOUNDATION BEAM WITHIN THIS REGION 1 1 EXCEPTION: PIPES MORE THAN 2'-0" BELOW BOTTOM OF GRADE BEAM DO NOT REQUIRE DEEPENED GRADE BEAM DEEPEN GRADE BEAM AS REQUIRED TO ALLOW FOR 6" CONCRETE (MINIMUM) AT PIPE PENETRATIONS. PIPE, 12" DIA MAX. - RE: PLUMBING6" CLEARDOWELS TO MATCH BOTTOM GRADE BEAM REINFORCEMENT 1.3 Ld 1.3 Ld SEE PLAN AND GRADE BEAM DETAIL FOR INFORMATION NOT SHOWN VERTICAL BEAM PENETRATION SLAB ON GRADE - SEE PLAN AT VERTICAL PIPE SLEEVE PENETRATIONS, PROVIDE ADDITIONAL #3 CLOSED STIRRUPS EA. SIDE OF SLEEVE. A Section at Plumbing Thru Grade Beam A Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:18:46 PMS3.000 Typical Foundation Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"3 Grade Beam Intersection 3/4" = 1'-0"4 Grade Beam Corner 3/4" = 1'-0"1 Slab on Grade Construction Joint 3/4" = 1'-0"8 Typical Step in Slab on Grade 3/4" = 1'-0"2 Slab on Grade Control Joint 3/4" = 1'-0"7 Typical Step in Grade Beam 3/4" = 1'-0"6 Grade Beam Face Reinforcement 3/4" = 1'-0"5 Section at Plumbing in Grade Beam No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 LAP SPLICE = 1.3ℓd 1 1/2"EQEQEQCONTINUOUS WATER-STOP AT CONDITIONS BELOW GRADE AND WHERE INDICATED ON PLANS / SECTIONS PER ARCH. VERTICAL CONSRUCTION JOINT REINFORCEMENT EACH FACE VERTICAL CONSRUCTION JOINT SINGLE LAYER OF REINFORCEMENT CONTINUOUS FULL HEIGHT SHEAR KEY 3"3"3"3"EQEQEQ3"3"3"3" LAP SPLICE = 1.3ℓd 1 1/2" NOTES: 1. AT CONDITIONS WHERE WALL SPANS HORIZONTALLY, CONTROL JOINTS TO BE LOCATED IN MIDDLE THIRD OF WALL SPANS (UNO). 2. CONTRACTOR TO SUBMIT CONTROL JOINT LOCATIONS PRIOR TO CONSTRUCTION TO EOR FOR REVIEW / APPROVAL. 3. RE: ARCHITECT FOR ADDITIONAL CONSTRUCTION JOINT REQUIREMENTS AND TREATMENT OF EXPOSED CONSTRUCTIO JOINTS. HORIZONTAL CONSRUCTION JOINT REINFORCEMENT EACH FACE HORIZONTAL CONSRUCTION JOINT SINGLE LAYER OF REINFORCEMENT 3"3"3"3"CONTINUOUS WATER-STOP AT CONDITIONS BELOW GRADE AND WHERE INDICATED ON PLANS / SECTIONS PER ARCH. CONTINUOUS FULL HEIGHT SHEAR KEY CONSTRUCTION JOINT TO HAVE 1/4" ROUGHNESS AMPLITUDE CONSTRUCTION JOINT LAP SPLICE = 1.3ℓdLAP SPLICE = 1.3ℓdCONSTRUCTION JOINT VERTICAL REINFORCEMENT MAY BE LAPPED OR RUN CONTINUOUS AT CONSTRUCTION JOINT AT CONTRACTORS OPTION HORIZONTAL REINFORCEMENT MAY BE LAPPED OR RUN CONTINUOUS AT CONSTRUCTION JOINT AT CONTRACTORS OPTION HORIZONTAL REINFORCEMENT MAY BE LAPPED OR RUN CONTINUOUS AT CONSTRUCTION JOINT AT CONTRACTORS OPTION AT BELOW GRADE CONDITIONS PROVIDE CONTINUOUS WATER-STOP - RE: ARCHITECT EQ EQ CONTROL JOINT 3/4"1/4". 1/2". CONTROL JOINT SPACINGHORIZONTALA A Elevation AT BELOW GRADE CONDITIONS, PROVIDE CONTINUOUS 12" WIDE STRIP OF FELT PAPER CENTERED ON CONTROL JOINT NOTES: 1. PROVIDE VERTICAL WALL CONTROL JOINTS AT 60'-0" O.C. MAXIMUM SPACING (UNO.) 2. AT CONDITIONS WHERE WALL SPANS HORIZONTALLY, CONTROL JOINTS TO BE LOCATED IN MIDDLE THIRD OF WALL SPANS (UNO). 3. CONTRACTOR TO SUBMIT CONTROL JOINT LOCATIONS PRIOR TO CONSTRUCTION TO EOR FOR REVIEW / APPROVAL. 4. RE: ARCHITECT FOR ADDITIONAL CONTROL JOINT REQUIREMENTS AND TREATMENT OF EXPOSED CONTROL JOINTS. (1/2" EXTERIOR CONTROL JOINT WIDTH MAY BE INCREASED TO MATCH ARCHITECTURAL INTENT. 5. AT BELOW GRADE CONDITIONS, CONTROL JOINT TO BE SEALED W/ WEATHER-RESISTANT SEALANT AT BELOW GRADE CONDITIONS, PROVIDE WATER-PROOFING PER ARCHITECT FOR REQUIREMENTS / LOCATIONS AT WALLS THAT SPAN VERTICALLY, ALTERNATING HORIZONTAL BARS TO STOP AT CONTROL JOINT. ( AT WALLS THAT SPAN HORIZONTALL, RUN ALL HORIZONTAL BARS CONTINUOUS) 3" EXTERIOR FACE INTERIOR FACE (1) U-BAR TO MATCH HORIZONTAL WALL REINFORCEMENT SIZE AND SPACING CORNER BAR TO MATCH HORIZONTAL WALL REINFORCEMENT SIZE AND SPACING (HOOK MAY BE PROVIDED AT END OF CONTINUOUS HORIZONTAL REINFORCEMENT AT INTERSECTING WALL IN PLACE OF CORNER BAR) (4) VERTICAL BARS TO MATCH VERTICAL WALL REINFOCEMENTLAP SPLICE = 1.3ℓd LAP SPLICE = 1.3ℓdLAP SPLICE = 1.3ℓdALTERNATE DIRECTION OF HOOK (2) VERTICAL BARS TO MATCH VERTICAL WALL REINFOCEMENT REINFORCEMENT EACH FACESINGLE LAYER OF REINFORCEMENT (2) U-BAR TO MATCH HORIZONTAL WALL REINFORCEMENT SIZE AND SPACING CORNER BAR TO MATCH HORIZONTAL WALL REINFORCEMENT SIZE AND SPACING (HOOK MAY BE PROVIDED AT END OF CONTINUOUS HORIZONTAL REINFORCEMENT IN ONE DIRECTION IN PLACE OF CORNER BAR) LAP SPLICE = 1.3ℓd LAP SPLICE = 1.3ℓdLAP SPLICE = 1.3ℓd LAP SPLICE = 1.3ℓd(4) VERTICAL BARS TO MATCH VERTICAL WALL REINFOCEMENT VERTICAL BAR TO MATCH VERTICAL WALL REINFOCEMENT REINFORCEMENT EACH FACESINGLE LAYER OF REINFORCEMENT 1'-4" MAXDROP (d)t (MIN)THK (t)EMBEDMENT = ℓd (1'-4" MAX)EQ(1'-4" MAX)EQt (MIN) EMBEDMENT = ℓd 2d (MIN) 1 2 1 2 THK (t)THK (t)THK (t)DROP (d)STEP FOOTING WHERE SHOWN ON PLAN STEP FOOTING WHERE SHOWN ON PLAN t (MIN)SCHEDULED STRIP / WALL FOOTING (WF) REINFORCEMENT SCHEDULED STRIP / WALL FOOTING (WF) REINFORCEMENT SCHEDULED STRIP / WALL FOOTING (WF) SCHEDULED STRIP / WALL FOOTING (WF) STEP d ≤1'-4" STEP d > 1'-4" PROVIDE REQUIRED NUMBER OF EQUAL STEPS IN FOOTING TO MEET TOTAL DROP (d) WITH MAX HEIGHT PER STEP HEIGHT OF 1'-4" MANUFATURERRE: ELEVATORSLAB ON GRADE WPC8X8.1 AT 24" O.C. MAX ELEVATOR SILL ANGLE - RE: ELEVATOR MANUFACTURER 8"SLAB ON GRADE 1' - 6"1' - 0"STAIR STINGER - RE: STAIR MANUFATURER L4X4X1/4 X 0'-5" CLIP ANGLE W/ 3/4"⌀X 4" EMBED EXPANSION ANCHOR (2) #5 CONT.GRADE BEAM TO EXTEND 1'-0" MIN. PAST STAIR STRINGER Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:18:48 PMS3.001 Typical Foundation Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Concrete Wall Construction Joint 3/4" = 1'-0"2 Concrete Wall Control Joint 3/4" = 1'-0"3 Concrete Wall Intersection 3/4" = 1'-0"4 Concrete Wall Corner 3/4" = 1'-0"5 Typical Step in Strip / Wall Footing 1" = 1'-0"6 Elevator Sill Angle 1" = 1'-0"7 Stair Stringer Attachment No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 Level 1 0" W/ ARCH VERFIY 7"1' - 0"8"2' - 0"10"4'-0" MIN. FROST PROTECTION9 1/2"SLAB ON GRADE -SEE PLAN CIP CONCRETE RETAINING WALL #4 @ 10" O.C. VERT #4 @ 12" O.C. HORIZ #4 @ 12" O.C. SHORT (B) (3) #5 CONT. (B) CIP CONCRETE STRIP WALL FOOTING RIGID INSULATION RE: ARCH & LOCAL CODE 3/4" RECESS AT DOOR THRESHOLDS -SEE PLAN A RECESS AT DOOR DETAIL W/ ARCH VERIFY#4 x 24" DOWELS @ 12" O.C. TYP. CONCRETE PATIO SLAB - RE: LANDSCAPE Level 1 0" 5 1/2"9 1/2"7" 1' - 0"8"2' - 0"2' - 0"10"4'-0" MIN. FROST PROTECTION10"7" S3.100 1 . S3.100 3 . LOAD BEARING WOOD STUD WALL -SEE PLAN AND SCHEDULE 2' - 0"10"4'-0" MIN. FROST PROTECTIONW/ ARCH VERIFY VARIES7" S3.100 3 . NO CURB @ SIM LOAD BEARING WOOD STUD WALL -SEE PLAN AND SCHEDULE CONT. #4 @ TOP #4 DOWELS @ 12" O.C.1' - 0"2' - 0"10"4'-0" MIN. FROST PROTECTION8"CONCRETE CURB -BEYOND EXTERIOR WALL -BEYOND PAVING -RE: CIVIL #4 @ 10" O.C. VERT #4 @ 12" O.C. HORIZ #4 @ 12" O.C. SHORT (B) (3) #5 CONT. (B) SLAB ON GRADE -SEE PLAN CIP CONCRETE RETAINING WALL CIP CONCRETE STRIP WALL FOOTING(ARCH VERIFY)1/2"(ARCH VERIFY) 10" Level 1 0" SLAB ON GRADE -SEE PLAN 2' - 0"2' - 0" (3) #5 CONT. (T&B) ADDITIONAL REINF. @ SHEARWALL HOLDOWNS AS SCHEDULED EXTEND BOTTOM GRADE BEAM REINF. INTO ADJACENT EXTERIOR STEM WALLS 1 2 #3 STIRRUPS @ 24" O.C. Level 1 0" Elevator Pit -5' -0" 1/2" x 0'-8" EMBED PLATE W/ (2) 1/2" DIA WHS x 6" LONG SPA. @ 5" O.C. AT 4'-0" O.C. MAX. AND 1'-6" MAX. FROM ENDS, TYP. ELEVATOR SILL ANGLE - RE: ELEVATOR MANUF. CIP CONCRETE RETAINING WALL. #4 @ 12" O.C. HORIZ. #5 @ 12" O.C. VERT. #5 @ 12" O.C. 3'-0" x 3'-0" DWLS, TYP. #5 @ 12" O.C. EA. WAY (T&B) CONT. SHEARKEY AND RX WATERSTOP, TYP. REF. ARCH.10".10"1 0 "10"8"1' - 0"1' - 0"8" 2'-0"x2'-0"x2'-0" (LxWxD) SUMP PIT -RE: PLUMBING #5 @ 12" BENT BARS x AS REQUIRED, TYP. #4 @ 12" EA. WAY BELOW SUMP PIT. EXTEND 2'-0" PAST SUMP PIT OR PROVIDE STD ACI HOOKS AT DISCONTINUOUS ENDS, TYP. (3) #5 x 6'-0" E.F. PROVIDE STD ACI HOOK AT DISCONTINUOUS ENDS, TYP. (3) #4 Z BARS W/ 1'-0" MIN. TAILS EA. SIDE OF SUMP PIT, TYP. SLAB ON GRADE - SEE PLAN 2'-0"x2'-0" #4 DOWELS @ 18" O.C. -TYP CMU WALL - SEE SCHEDULE DOWELS TO MATCH VERT. CMU WALL REINFORCEMENT SEE CMU LAP SCHEDULE2' - 0" 1 2 (2) #5 CONT. (T&B) AT SHEARWALL HOLD DOWNS ONLY PROVIDE ADDITIONAL (2) #6 x 12'-0" (T) W/ (6) #3 STIRRUPS @ 6" O.C. SEE BRACING PLANS FOR LOCATIONS. #3 STIRRUPS @ 24" O.C. SLAB ON GRADE - SEE PLAN WOOD STUD WALL SEE PLAN & SCHEDULE #4 DOWELS @ 18" O.C. #4 CONT.VARIES1' - 6"W/ ARCH VERIFY EXTEND BOTTOM GRADE BEAM REINF. INTO ADJACENT EXTERIOR STEM WALLS Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:18:54 PMS3.100 Foundations Sections Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Section at Exterior Stem Wall and Footing 3/4" = 1'-0"4 Section at Exterior Stem Wall and Footing at Balcony 3/4" = 1'-0"2 Section at Exterior Stem Wall and Footing @ Garage 3/4" = 1'-0"3 Section at Exterior Stem Wall and Footing @ OH Garage Door 3/4" = 1'-0"5 Section at Interior Grade Beam 3/4" = 1'-0"6 Elevator Pit Detail 3/4" = 1'-0"7 Section at Interior Garage Wall No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 Level 1 0" PAVING -RE: CIVIL/LANDSCAPE MASONRY VENEER - RE: ARCH #5 @ 12" O.C. EA. FACE VERT. #4 @ 12" O.C. EA. FACE HORIZ.4' - 0" MIN. FROST DEPTH4"5 1/2"1' - 1 1/2"5 1/2" (SEE PLAN FOR LENGTH) 2' - 0 1/2"(3) #5 CONT (B) & #4 SHORT (B) @ 12" O.C. FULLY GROUT BEHIND ALL BRICK BELOW GRADE, TYP. Level 1 0" SEE SCHED.SEE SCHED.3'-0" MIN.4"T.O. FOOTING -SEE PLAN PAVING -RE: CIVIL/LANDSCAPE MASONRY VENEER - RE: ARCH WOOD COLUMN BASE - SEE PLAN (8) #5 VERT W/ #3 TIES @ 6" O.C. 5 1/2" 9" SQUARE 5 1/2" 1' - 8" SQUARE FULLY GROUT BEHIND ALL BRICK BELOW GRADE, TYP. Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:10:25 PMS3.101 Foundation Details Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"2 Strip Wall Footing Detail at Exterior Wood Wall. 3/4" = 1'-0"1 Spread Footing Detail at Exterior Wood Column. 1 No. Description Date 1 RFI 015 03/05/26 100% IFC 03/18/26 FLOOR TRUSS 2X LOAD BEARING EXTERIOR STUD WALL - SEE PLAN AND SCHEDULE DOUBLE 2X TOP PLATE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3 1/2" LONG NAILS (TYPICAL) 2X LOAD BEARING EXTERIOR STUD WALL -SEE PLAN AND SCHEDULE EDGE NAILING (TYPICAL) NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT BLOCKING AS REQUIREDGAPRELIEF2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X NON-LOAD BEARING EXTERIOR STUD WALL -SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X NON-LOAD BEARING EXTERIOR STUD WALL - SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT FLOOR TRUSSGAPRELIEFHORIZONTAL BRIDGING -RE: TRUSS MANUFACTURER DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING INTERIOR STUD WALL - SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) 2X LOAD BEARING INTERIOR STUD WALL - SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT FLOOR TRUSS FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING INTERIOR STUD WALL - SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) 2X LOAD BEARING INTERIOR STUD WALL -SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT FLOOR TRUSS HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS 2X LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) 2X LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE EDGE NAILING (TYPICAL) NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT FLOOR TRUSS • FLOOR SHEATHING PANEL EDGES SHALL NOT OCCUR WITHIN AIR GAP, JOINTS TO OCCUR OVER EITHER WALL FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS DOUBLE 2X TOP PLATE EA. WALL DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X NON-LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE 2X NON-LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE FLOOR TRUSS 2X LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT FLOOR TRUSS 2' - 0" MAX • FLOOR SHEATHING PANEL EDGES SHALL NOT OCCUR WITHIN AIR GAP, JOINTS TO OCCUR OVER EITHER WALL HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER 2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS FLOOR TRUSS 2X INTERIOR SHEAR WALL 2X BOTTOM PLATE DOUBLE 2X TOP PLATE FLOOR SHEATHING FLOOR TRUSS EDGE NAILING (TYPICAL) EDGE NAILING (TYPICAL) NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) 2X INTERIOR SHEAR WALL HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER FLOOR TRUSS 2X NON-LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X NON-LOAD BEARING DEMISING STUD WALL - SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2' - 0" MAX 2' - 0" MAX • FLOOR SHEATHING PANEL EDGES SHALL NOT OCCUR WITHIN AIR GAP, JOINTS TO OCCUR OVER EITHER WALL DOUBLE 2X TOP PLATE EA. WALL EDGE NAILING (TYPICAL) FLOOR TRUSS HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING INTERIOR STUD WALL - SEE PLAN AND SCHEDULE 2X4 CONT. FASTENED TO EACH STUD WITH (2) 0.148"⌀X 3" LONG NAILS (TYPICAL) FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING INTERIOR STUD WALL -SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT FLOOR TRUSS MECH CHASEMINUS 3"TRUSS DEPTHCOORD W/ MEP 1'-10" MAX 2X SOLID BLOCKING BETWEEN TRUSS BEARING CHORDS CONT 2X FLOOR TRUSS 2X LOAD BEARING INTERIOR STUD WALL - SEE PLAN AND SCHEDULE DOUBLE 2X TOP PLATE HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER 2X LOAD BEARING INTERIOR STUD WALL - SEE PLAN AND SCHEDULE FLOOR TRUSS 2X STUD WALL FLOOR SHEATHING 2X BOTTOM PLATE EDGE NAILING (TYPICAL) 2X STUD WALL GYPCRETE TOPPING - RE: ARCH. 2X8 CONT. W/ (3) 0.162x3 1/2" NAILS EA. OUTRIGGER. 2X8 FRT OUTRIGERS @ 16" O.C. 3' - 0" MAX. RE: ARCH. TRUSS BAYS W/ (5) 0.148"X3" NAILS EACH TRUSS EXTEND OUTRIGGERS AND NAIL TO (3) FASTEN EACH OUTRIGGER TO ADJACENT STUD W/ (5) 0.148"X3" NAILS EACH TRUSS & STUD ROOF SHEATHING - RE: ARCH4 1/2"AS R EQ U IR ED 1" 1 1/2"2 1/2"1"1"2 1/4"1 1/8"1 1/8"1" 3 1/2" HANDRAIL SYSTEM - RE: ARCH 2X STUD WALL (3) SIMPSON SDS25312 SCREWS STUD PACK -SEE PLAN AND GENERAL NOTES 1/4" THK BENT PLATE ADDITIONAL TRIMMER - RE: ARCH DOOR / WINDOW SYSTEM -RE: ARCH. Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:00 PMS4.110 Framing Sections - Wood Floor Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Truss Bearing Exterior 3/4" = 1'-0"2 Truss Parallel to Exterior 3/4" = 1'-0"3 Truss Bearing Interior - Both Sides 3/4" = 1'-0"4 Truss Bearing Interior - One Side 3/4" = 1'-0"6 Truss Bearing Interior - Demising Wall - Both Sides 3/4" = 1'-0"7 Truss Bearing Interior - Demising Wall - One Side 3/4" = 1'-0"5 Truss Parrallel to Interior Shear Wall 3/4" = 1'-0"8 Truss Parallel Interior - Demising Wall 3/4" = 1'-0"11 Truss Bearing at Corridor 3/4" = 1'-0"9 Section at Cantilevered Wood Canopy Framing 1 1/2" = 1'-0"10 Juliet Balcony Handrail Connection No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 EDGE NAILING (TYPICAL) 2X LOAD BEARING DEMISING STUD WALL -SEE PLAN AND SCHEDULE FLOOR SHEATHING FLOOR TRUSS 2X LOAD BEARING DEMISING STUD WALL -SEE PLAN AND SCHEDULE (2) 2X TOP PLATE EA WALL EDGE NAILING (TYPICAL) (2) BOTTOM PLATE EA WALL ELEVATOR SHAFT PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS CMU ELEVATOR SHAFT WALL -SEE PLAN AND SCHEDULE EDGE NAILING (TYPICAL) 2X LOAD BEARING DEMISING STUD WALL -SEE PLAN AND SCHEDULE FLOOR SHEATHING FLOOR TRUSS 2X LOAD BEARING DEMISING STUD WALL -SEE PLAN AND SCHEDULE DOUBLE 2X TOP PLATE EA WALL EDGE NAILING (TYPICAL) 2X BOTTOM PLATE EA WALL AT CONTRACTORS OPTION (2) ADD'L 2X TOP PLATES ELEVATOR SHAFT PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS CMU ELEVATOR SHAFT WALL -SEE PLAN AND SCHEDULE ROOF TRUSS ROOF SHEATHING 2X LOAD BEARING STUD WALL -SEE PLAN AND SCHEDULE ELEVATOR SHAFT DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) ELEVATOR GUIDE RAILS SUPPORTS AND ATTACHMENTS TO CMU BY ELEVATOR SUPPLIER (TYP) CMU WALL -SEE PLAN AND SCHEDULE PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS ELEVATOR HOIST BEAM TRUSS BLOCK PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS CONT. 2X ROOF JOIST ROOF SHEATHING 1 1/2" CLRFULL HEIGHT 2X RIM JOIST (RIPPED TO FIT) EDGE NAILING (TYPICAL) SIMPSON A35 CLIP @ 24" O.C. 1/4" / 12" ROOF SYSTEM -RE: ARCH. SIMPSON H2.5 @ EA. ROOF JOIST ROOF TRUSS ROOF SHEATHING 2X LOAD BEARING STUD WALL -SEE PLAN AND SCHEDULE ELEVATOR SHAFT DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) ELEVATOR GUIDE RAILS SUPPORTS AND ATTACHMENTS TO CMU BY ELEVATOR SUPPLIER (TYP) CMU WALL -SEE PLAN AND SCHEDULE PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS ELEVATOR HOIST BEAM BEYOND ROOF JOIST PROVIDE CONTINUOUS FULLY GROUTED DOUBLE BOND BEAM AT TOP W/ (2) #5 CONT AND #2 U-BARS @ 12" O.C. ROOF SHEATHING SIMPSON A35 CLIP @ 24" O.C. ROOF SYSTEM -RE: ARCH. EDGE NAILING (TYPICAL) (9 1/4" MIN)VARIESCLR1 1/2"GIRDER TRUSS ROOF SHEATHING ELEVATOR SHAFT DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) CMU WALL -SEE PLAN AND SCHEDULE PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS ELEVATOR HOIST BEAM PROVIDE CONTINUOUS BOND BEAM PER TYPICAL CMU DETAILS ROOF JOIST ROOF SHEATHING 1 1/2" CLRFULL HEIGHT 2X RIM JOIST (RIPPED TO FIT) EDGE NAILING (TYPICAL) SIMPSON A35 CLIP @ 24" O.C. 1/4" / 12" ROOF SYSTEM -RE: ARCH. SIMPSON H2.5 @ EA. ROOF JOIST MIN9 1/4"TRUSS HANGER ROOF TRUSS ELEVATOR DOOR -RE: ARCH. CMU LINTEL -SEE SCHEDULE ELEVATOR DIVIDER BEAM -SEE PLAN EMBED PL3/8X6X0'-9" W/ (2) 5/8"⌀X 4" H.S.A. GROUT BEAM POCKET SOLID W/ 2500 PSI NON-SHRINK GROUT CMU WALL -SEE SCHEDULE FULLY GROUTED CMU BOND BEAM W/ (2) #5 CONT.2"1 1/2"6"1 1/2"6" 2 1/4"3 3/4"9"FLOOR SHEATHING BEARING 4" MIN ELEVATOR HOIST BEAM - SEE PLAN. RE: ELEVATOR MANUFACTURE FOR LOCATION EMBED PL3/8X6X0'-9" W/ (2) 5/8"⌀X 4" H.S.A. 6" GROUT BEAM POCKET SOLID W/ 2500 PSI NON-SHRINK GROUT CMU WALL -SEE SCHEDULE FULLY GROUTED CMU BOND BEAM W/ (2) #5 CONT.1 1/2"6"1 1/2"6" 2 1/4"3 3/4"9"BEARING 4" MIN CMU WALL -SEE SCHEDULE FULLY GROUTED CMU BOND BEAM W/ (2) #5 CONT. AT TALL FLOORS, PROVIDE INTERMEDIATE FULLY GROUTED CMU BOND BEAM W/ (2) #5 CONT. EQUAL DISTANCE BETWEEN FLOORS. RE: ELEVATOR MANUFACTURER WHEN REQUIRED FINISH FLOOR ELEVATOR SHAFT ELEVATOR RAILS - RE: ELEVATOR MANUFACTURER POST-INSTALLED ANCHOR -RE: ELEVATOR MANUFACTUREF FOR CONNECTION INTERMEDIATE POST- INSTALLED ANCHOR AT TALL FLOORS WHERE REQUIRED- RE: ELEVATOR MANUFACTUREF FOR CONNECTION ELEVATOR GUIDE RAILS SUPPORTS AND ATTACHMENTS TO CMU BY ELEVATOR SUPPLIER (TYP) DBL 2x12 PRESSURE TREATED LEDGER FASTENED TO DBL BOND BEAM W/ 1/2" DIA x 8" LONG STAINLESS STEEL TITEN HD ANCHORS @ 8" O.C. 16 1/2" CORRIDOR TRUSS FLOOR SHEATHING ELEVATOR DOOR - RE: ARCH ELEVATOR DOOR - RE: ARCH ELEVATOR SHAFT ELEVATOR SILL ANGLE - RE: ELEVATOR MANUFACTURER DOUBLE 8" CMU BOND BEAM 2X8 CONT FASTENED TO CMU BOND BEAM W/ SIMPSON TITEN HD 75600H @ 24" O.C. EDGE NAILING (TYPICAL)4"METAL STUD INFILL AS REQUIRED W/ SHAFT LINER - RE: ARCH. FLOOR TRUSS FLOOR SHEATHING BALCONY BEAM FLOOR TRUSS EDGE NAILING (TYPICAL) (2) 2X6 BLOCKING Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:19:07 PMS4.210 Elevator Framing Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Truss Bearing at Elevator Shaft - CMU 3/4" = 1'-0"2 Truss Parralel to Elevator Shaft-Double Wall 3/4" = 1'-0"6 Truss Bearing at Elevator Shaft - CMU 3/4" = 1'-0"7 Truss Bearing at Elevator Shaft - CMU 3/4" = 1'-0"8 Truss Bearing at Elevator Shaft - CMU 3/4" = 1'-0"4 Elevator Hoist Beam Bearing at CMU Wall 3/4" = 1'-0"9 Elevator Hoist Beam Bearing at CMU Wall 3/4" = 1'-0"5 Elevator Hoist Beam Bearing at CMU Wall 3/4" = 1'-0"3 Corridor Truss Bearing at Elevator Shaft 3/4" = 1'-0"10 Truss Bearing at Flush Beam No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 ROOF TRUSS ROOF SHEATHING CEILING -RE: ARCH DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING EXTERIOR STUD WALL - SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT BLOCKING • WHERE 'H' EXCEEDS 11 1/4", PROVIDE TRUSS BLOCKING BETWEEN EA TRUSS • WHERE 'H' DOES NOT EXCEED 11 1/4", PROVIDE 2X RIPPED TO FIT SIMPSON H2.5A CLIP AT EA. TRUSS HROOF SHEATHING 2X STUD WALL 2X BLOCK RIPPED TO FIT LEAVE EVERY THIRD TRUSS BAY OPEN FOR ROOF VENTING ROOF SHEATHING DOUBLE 2X TOP PLATE 2X STUD WALL TRUSS BLOCK OVER WALL BETWEEN TRUSSES HA A BLOCKING AT 2X CONDITION (H ≤12") A BLOCKING AT TRUSS BLOCK CONDITION (H > 11 1/4") EDGE NAILING (TYPICAL) 2X CONT. W/ (3) 0.148"⌀X 3 1/4" NAILS INTO EA. TRUSS EDGE NAILING (TYPICAL) 2X4 FLAT BLOCKING AT PERIMETER OF OPEN BAY ROOF TRUSS DOUBLE 2X TOP PLATE OPEN OPEN ROOF TRUSS PROVIDE SHEATHING EDGE NAILING AT TRUSS BLOCKS PROVIDE SHEATHING EDGE NAILING AT ALL BLOCKING ROOF TRUSS ROOF SHEATHING CEILING -RE: ARCH DOUBLE 2X TOP PLATE EDGE NAILING (TYPICAL) 2X LOAD BEARING EXTERIOR STUD WALL - SEE PLAN AND SCHEDULE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2x6 OUT-RIGGER AT 24" O.C.MAX GABLE END ROOF TRUSS (DROPPED FOR OUT-RIGGER) INVERTED SIMPSON LU26 @ EA. OUT- RIGGER 2x6 CONT. SIMPSON H2.5 CLIP AT EA. OUT- RIGGER DIAGONAL BRACE - SEE SCHEDULE 1 1 PROVIDE 2X6 BLOCKING AT DIA BRACE LOCATION W/ SIMPSON A34 CLIP EA. END VERTICAL BRACE WHERE REQUIRED - SEE SCHEDULE PROVIDE 2X6 BLOCKING AT DIAGONAL BRACE LOCATION W/ SIMPSON A34 CLIP EA. END ATTACH DIAGONAL BRACE TO BLOCKING W/ (5) 0.148"⌀x 3" NAILS EA. END 2x6 BLOCKING BETWEEN OUT-RIGGERS GABLE HEIGHT (H)GABLE HEIGHT (H) 0' TO 5'-0" GABLE BRACING SCHEDULE 5'-1" TO 10'-0" DIAGONAL BRACEVERTICAL BRACE 1 NONE 2X4@ 6'-0" O.C. 2X4 2X6 2X6 @ 4'-0" O.C. 2X6 W/ 2X6 'T' STIFF. @ 4'-0" O.C.10'-1" TO 15'-0" NOTES: 1. VERTICAL BRACES TO BE INSTALLED @ 2' O.C. MAX 2X4 TRUSS BOTTOM CHORD BRACING WHERE "H" EXCEEDS 10'-0" (MATCH DIAGNONAL BRACING) EXTEND 4 TRUSS BAYS "T" STIFF WHERE REQUIRED -SEE SCHEDULE EDGE NAILING (TYPICAL) 2X INTERIOR LOAD BEARING STUD WALL DOUBLE 2X TOP PLATE 2X6 BLOCKING (ON EDGE) AT DIAGONAL BRACE LOCATION ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER EDGE NAILING (TYPICAL) NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT EDGE NAILING (TYPICAL) ROOF TRUSSES ON SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF. ROOF SHEATHING 2X4 DIAGONAL BRACE TO 2X BLOCKING (LAID FLAT) AT DIAGONAL BRACE LOCATION 2X INTERIOR LOAD BEARING STUD WALL DOUBLE 2X TOP PLATE ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER EDGE NAILING (TYPICAL) NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT ROOF TRUSSES ON SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF. ROOF SHEATHING TO 2X BLOCKING (LAID FLAT) -ATTACH PER FASTENING SCHEDULE TRUSS BLOCK -RE: TRUSS MANUFACTURER TRUSS HEIGHT OVER WALL (H) ≤3'-0" TRUSS HEIGHT OVER WALL (H) > 3'-0" EDGE NAILING (TYPICAL) TRUSS MANUFACTURER TO PROVIDE VERTICAL CHORD OVER WALLTRUSS HEIGHT OVER WALL (H)TRUSS HEIGHT OVER WALL (H)S4.310 .6_______ S4.310 .6_______ ROOF SHEATHING EDGE NAILING (TYPICAL) 2X SHEAR WALL DOUBLE TOP PLATE ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER EDGE NAILING (TYPICAL) 2X CONT -ATTACH PER FASTENING SCHEDULENOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2X CONT -ATTACH PER FASTENING SCHEDULE ROOF TRUSS - PROFILE VARIES - RE: ARCH / TRUSS MANUFACTURER HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER ROOF TRUSSES / TRUSS BLOCKS LOCATED ABOVE SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2X TOP PLATE EACH WALL W/ ADDITONAL 2X RIPPED TO FIT TOP PLATE OVER BOTH WALLS - 2X CONT -ATTACH PER FASTENING SCHEDULE EDGE NAILING (TYPICAL) 2X NON-LOAD BEARING DEMISING STUD WALL ROOF SHEATHING EDGE NAILING (TYPICAL) ROOF TRUSSES / TRUSS BLOCKS LOCATED ABOVE SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER 2X CONT -ATTACH PER FASTENING SCHEDULE HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER ROOF SHEATHING EDGE NAILING (TYPICAL) 2X INTERIOR LOAD BEARING STUD WALL TRUSS -SEE PLAN / RE: TRUSS MANUFACTURER ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER EDGE NAILING (TYPICAL) 2X BLOCKING -ATTACH PER FASTENING SCHEDULENOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2X4 CONT. DOUBLE TOP PLATE 2X CONT -ATTACH PER FASTENING SCHEDULE ROOF TRUSS - PROFILE VARIES - RE: ARCH / TRUSS MANUFACTURER HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER ROOF TRUSSES / TRUSS BLOCKS LOCATED ABOVE SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF ROOF SHEATHING EDGE NAILING (TYPICAL) ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT 2X TOP PLATE EACH WALL W/ ADDITONAL 2X RIPPED TO FIT TOP PLATE OVER BOTH WALLS - EDGE NAILING (TYPICAL) 2X NON-LOAD BEARING DEMISING STUD WALL ROOF TRUSS -PROFILE VARIES -RE: ARCH / TRUSS MANUFACTURER 2X CONT -ATTACH PER FASTENING SCHEDULE HORIZONTAL BRIDGING - RE: TRUSS MANUFACTURER ROOF TRUSSES / TRUSS BLOCKS LOCATED ABOVE SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF ROOF TRUSS ROOF SHEATHING DOUBLE 2X TOP PLATE 2X4 DIAGONAL BRACE PROVIDE 2X6 BLOCKING AT DIAGONAL BRACE LOCATION (2 TRUSS BAYS) PROVIDE 2X6 BLOCKING (ON EDGE) ADJACENT TO 2X BLOCKING (LAID FLAT) AT DIAGONAL BRACE LOCATION (2 TRUSS BAYS) ATTACH DIAGONAL BRACE TO BLOCKING W/ (4) 0.148"⌀x 3 1/4" NAILS EA. END 1 TRUSS HEIGHT OVER WALL (H)ROOF TRUSS ROOF SHEATHING TRUSS HEIGHT OVER WALL (H)2X STUD WALL TRUSS BLOCK -RE: TRUSS MANUFACTURER ATTACHED DIAGONAL BRACE AT EA. TRUSS TO VERT CHORD W/ (2) 0.148"⌀x 3 1/4" NAILS ATTACH SHEATHING TO 2X6 BLOCKING W/ 0.148"⌀x 3" NAILS @ 4" O.C. ATTACH BLOCKING LAID FLAT TO UPPER TOP PLATE W/ 0.148"⌀x 3" NAILS @ 4" O.C. ATTACH BLOCKING ON EDGE TO BLOCKING LAID FLAT W/ 0.148"⌀x 3 1/2" NAILS @ 4" O.C. 2X BLOCKING BEYOND (LAID FLAT) -ATTACH TO UPPER TOP PLATE AND TRUSS BLOCK PER FASTENING SCHEDULE TRUSS HEIGHT OVER WALL (H) ≤3'-0" TRUSS HEIGHT OVER WALL (H) > 3'-0" ADUST SLOPE TO ALLOW DIAGONAL BRACES TO END AT FACE OF TRUSS TOP / BOTT CHORD AS SHOWN 1 MIN 1.25 MAX 1 1 MIN 1.25 MAX DOUBLE 2X TOP PLATE 2X STUD WALL TOE-NAIL BLOCKING INTO TRUSS TOP / BOTT CHORD W/ (3) 0.148"⌀x 3 1/2" NAILS EA. END. (TYPICAL) ROOF TRUSSES / TRUSS BLOCKS LOCATED ABOVE SHEAR WALLS SHALL BE DESIGNED FOR DRAG FORCE (D.F.) -SEE ROOF PLAN FOR REQUIRED LOADS. TRUSSES WITHOUT DESIGNATED LOADS SHALL BE DESIGNED FOR 350 PLF DOUBLE 2X TOP PLATE NOTE: • AT SHEAR WALL LOCATIONS SEE SHEARWALL SCHEDULE FOR STUD WALL, SHEATHING, TYPE & EDGE NAILING, AND BOTTOM PLATE ATTACHMENT. • AT NON-SHEAR WALL LOCATIONS SEE STUD SCHEDULE FOR STUD WALL AND FASTENING SCHEDULE FOR EDGE NAILING AND BOTTOM PLATE ATTACHMENT EDGE NAILING - TYPICAL 2X STUD WALLCORRIDOR CHASE 1' - 6" MECHANICAL A/C UNIT A/C UNIT CEILING -RE: ARCH ROOF SHEATHING ROOF TRUSS NOTE:MECHANICAL CHASE SHOWN IN CENTER BAY OF TRUSS. CHASE MAY BE LOCATED AT EITHER END BAY OF TRUSS, COORDINATE LOCATION WITH ARCH / MEP TRUSS BLOCK TRUSS BLOCK ROOF TRUSS A/C UNIT B B ROOF SHEATHING ROOF TRUSSES (DESIGNED FOR ADDITIONAL ROOF TOP EQUIPMENT PER STRUCT AND MECH DRAWINGS) 4X4 PT SLEEPER -RE: MECH FASTEN 4X4 TO BLOCKING W/ (2) SDWS25600 SCREWS PER STAND BASE (4 SCREWS PER BOARD) MECH UNIT & STAND BY OTHERS -RE: MECH (2)2X8 FLAT BLOCKING FASTENED TO ROOF TRUSS W/ (3) SDWC15450 SCREWS Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:19:16 PMS4.310 Framing Sections - Wood Roof Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Exterior Roof Truss Bearing 3/4" = 1'-0"2 Gable Roof Truss Section 3/4" = 1'-0"3 Roof Truss Bearing at Interior Bearing Wall / Shear Wall 3/4" = 1'-0"4 Roof Truss Parallel to Interior Shear Wall 3/4" = 1'-0"8 Roof Truss Parallel to Unit Demising Wall 3/4" = 1'-0"5 Roof Truss Bearing at Interior Bearing Wall - One Side 3/4" = 1'-0"9 Roof Truss Bearing at Unit Demising Wall - One Side 3/4" = 1'-0"6 Truss Blocking / Bracing Over Wall 3/4" = 1'-0"7 Truss Bearing at Corridor w/ Mechanical Line Set Knee Wall No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 GIRDER TRUSS -RE: TRUSS MANUFACTURER ROOF TRUSS - SEE PLAN FLAT ROOF TRUSSES - SEE PLAN 2X LOAD BEARING STUD WALL -SEE PLAN AND SCHEDULE 2X LOAD BEARING STUD WALL -SEE PLAN AND SCHEDULE ROOF SHEATHING SHEATH W TYPE 'D' SHEARWALL -SEE SHEARWALL SCHEDULE2x6 CONT. S4.310 1 .SIM S4.310 4 . GIRDER TRUSS - SEE PLAN GIRDER TRUSS - SEE PLAN TRIPLE 2x12 BEAM -SEE PLAN 2x12 JOISTS @ 24" O.C. W/ HU212 HANGERS EACH END. 2x12 LEDGER 2x6 ROOFTOP WALL PANEL W/ STUDS @ 16" O.C. & TRIPLE 2x6 HADER -SHEATH EXTERIOR W/ W.S.P. PER SHEARWALL TYPE 'D' 2x6 ROOF JOISTS @ 12" O.C. ROOF TRUSS - SEE PLAN 2X LOAD BEARING STUD WALL -SEE PLAN AND SCHEDULE ROOF TRUSSES - SEE PLAN ACCESS DOOR W/ PULL DOWN LADDER BY OTHERS ROOF SHEATHING ROOF SHEATHING ROOF ACCESS DOOR BY OTHERS -RE: ARCH Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:19:18 PMS4.311 Framing Sections - Wood Roof Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Roof Framing Detail at Mechanical Well 3/4" = 1'-0"2 Roof Framing Detail at Roof Access Platform No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 Roof 10' -6" Eave 10' -2" SCISSOR TRUSS VALLEY SET TRUSS / FRAMING GIRDER TRUSS - SEE PLAN ROOF TRUSS - SEE PLAN 2X LOAD BEARING EXTERIOR STUD WALL - SEE PLAN AND SCHEDULE CONNECTION BY TRUSS MANUF, TYP. ROOF SHEATHING 2X CONT. ROOF SHEATHING TRUSS BLOCK VAULTED CEILING, RE: ARCH & INTERIORS FOR EXTENTS NOTE: SEE ROOF TRUS UPLIFT TABLE ON S5.421 OR S5.521 FOR ADDITIONAL HARDWARE NOT SHOWN HERE ROOF CLIP, TYP. SEE ROOF TRUSS UPLIFT DETAILS. 2X BLOCKING AS REQUIRED FOR EDGE NAILING, TYP. FLOOR JOISTS - SEE PLAN FLOOR SHEATHING RAFTER FRAMING - SEE PLAN ROOF SHEATHING ROOF TRUSSES - SEE PLAN BLOCKING & EDGE NAILING, TYP. 2X8 CONT. W/ (3)0.131"X3" NAILS @ EA. RAFTER 2X OVERFRAMING -SEE PLAN DOUBLE TOP PLATE DOUBLE TOP PLATE 2X CONT. LEDGER - SEE TYP. CONNECTION DETAILS H2.5A CLIP @ EA. RAFTER Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:10:25 PMS4.312 Framing Sections - Wood Roof Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Section at Vaulted Ceiling 3/4" = 1'-0"2 Framing Section at Mechanical Room No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 A S4.313 2_______ 6X6 MEMBER (MATCH TYPE AND GRADE OF ADJACENT TRUSS MEMBERS) 6x14 DOUGLAS FIR #1 GRADE OR 5-1/8x11-7/8 EXTERIOR GRADE GLU-LAM Beam Height 12' -8" CONTINUOUS BEAM -SEE PLAN WOOD POST -SEE PLAN 1/4"x4" WIDE STEEL ELBOW PLATE EA. SIDE OF TRUSS W/ (8)1/2" DIA A36 THRU BOLTS - RE: ARCH FOR PLATE AND BOLT FINISHING AND PLATE EDGE TREATMENT (CHAMFERING, ETC.) 6" 1/4"x4"x1'-8" STEEL PLATE EA. SIDE OF TRUSS W/ (8)1/2" DIA A36 THRU BOLTS - RE: ARCH FOR PLATE AND BOLT FINISHING AND PLATE EDGE TREATMENT (CHAMFERING, ETC.) 6" 2" STAGGERED, TYP.1" BRICK VENEER -RE: ARCH WOOD POST -SEE PLAN BRICK VENEER -RE: ARCH SIMPSON APVT6 FLAT STRAP EACH SIDE OF POST TO BEAM OR APPROVED EQUAL -RE: ARCH 6x14 DOUGLAS FIR #1 GRADE OR 5-1/8x11-7/8 EXTERIOR GRADE GLU-LAM2" STAGGERED, TYP.NOTE: EXTERIOR GRADE GLU-LAMS SHALL BE PRESSURE-TREATED GLU-LAM MEMBERS TREATED AFTER FABRICATION (PTAF) WITH A PTI-BASED CLEAR PRESERVATIVE SUITABLE FOR EXTERIOR, ABOVE-GROUND USE. PRESERVATIVE MUST BE NON-METALLIC AND LEAVE NO GREEN TINT. CONTRACTOR SHALL SUBMIT MATERIAL TO ARCH AND EOR FOR APPROVAL.6" MIN.PRE-DRILL INTERIOR CORNER OF STRINGER. CARE SHOULD BE TAKEN TO AVOID OVER CUTTING. PROVIDE (4) SIMPSON SDWC15600 SCREWS (2 NS & 2 FS) PROVIDE (4) SIMPSON SDWC15600 SCREWS (2 NS & 2 FS) 1 1 WOOD BEAM - SEE ROOF SHEATHING 2x4 BLOCKING OVER EACH BEAM MEMBER 2x4 JOISTS @ 16" O.C. 1x BLOCKING @ 16" O.C. EXPOSED T&G CEILING TREATMENT -RE: ARCH / INTERIORS /1 S4.313 1 Roof 10' -6" Beam Height 12' -8" 2X LOAD BEARING EXTERIOR STUD WALL -SEE PLAN AND SCHEDULE ROOF SHEATHING GABLE TRUSSES - SEE PLAN GLU LAM BEAM - SEE PLAN (3)2x4 PONYSTUDS BELOW BEAM & (1)2x4 PONYSTUD FULL HEIGHT FASTENED TO TOP AND BOTTOM CHORDS W/ (3)0.148"x3" NAILS A Beam Bearing at Gable End ROOF SHEATHING BEAM -SEE PLAN GABLE TRUSS - SEE PLAN 2x4 PONY STUDS BEHIND GABLE TRUSS DOUBLE 2X TOP PLATE STUDPACK Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:10:26 PMS4.313 Framing Sections - Wood Roof Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Roof Framing Detail at Covered Porch 3/4" = 1'-0"2 Decking Detail at Covered Porch 3/4" = 1'-0"3 Glu Lam Beam Support at Exterior Wall Details No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 1 RFI 015 03/05/26 100% IFC 03/18/26 T.O High Windows 9' -6" ROOF SHEATHING GIRDER TRUSS - SEE PLAN ROOF CLIP WINDOW SYSTEM - RE: ARCH. WOOD BEAM - SEE PLAN 2X CONT. ROOF SHEATHING ROOF SHEATHING 2X CONT. ROOF TRUSS - SEE PLAN ROOF TRUSS - SEE PLAN GIRDER TRUSS - SEE PLAN CONNECTION BY TRUSS MANUF, TYP. NOTE: SEE ROOF TRUSS UPLIFT TALBE ON S5.421 OR S5.521 FOR ADDITIONAL HARDWARE NOT SHOWN HERE. 2x BLOCKING BETWEEN TRUSS CHORDS CEILING ELEVATION = (VERIFY W/ INTERIORS) CEILING ELEVATION = (VERIFY W/ INTERIORS) CEILING ELEVATION = (VERIFY W/ INTERIORS) 2x OVERFRAME - RE: INTERIORS SEE DETAIL 1/S4.310 FOR TRUSS ATTACHMENT TO BEAM 10' - 6" 11' - 6" 16' - 11" (FACE OF STUD TO FACE OF STEP IN TRUSS) 8'-0". T.O High Windows 9' -6" WOOD BEAM - SEE PLAN 2X CONT. ROOF SHEATHING GIRDER TRUSS - SEE PLAN NOTE: SEE ROOF TRUSS UPLIFT TABLE ON S5.421 OR S5.521 FOR ADDITIONAL HARDWARE NOT SHOWN HERE. ROOF CLIP WINDOW SYSTEM - RE: ARCH. 2X CONT. ROOF SHEATHING ROOF TRUSS - SEE PLAN GIRDER TRUSS - SEE PLAN CONNECTION BY TRUSS MANUF, TYP. ROOF TRUSS - SEE PLAN NOTE: SEE ROOF TRUSS UPLIFT TALBE ON S5.421 OR S5.521 FOR ADDITIONAL HARDWARE NOT SHOWN HERE. CONNECTION BY TRUSS MANUF, TYP. CEILING ELEVATION = (VERIFY W/ INTERIORS) CEILING ELEVATION = (VERIFY W/ INTERIORS)2x OVERFRAME - RE: INTERIORS SEE DETAIL 1/S4.310 FOR TRUSS ATTACHMENT TO BEAM 11' - 6" 10' - 6" (FACE OF STUD TO FACE OF GT) 7' - 9 3/4" T.O High Windows 9' -6" BRICK VENEER - RE: ARCH. LOOSE LINTEL - SEE SCHEDULE WOOD BEAM - SEE PLAN 2X ROOF JOIST - SEE PLAN ROOF SHEATHING CONTINUOUS 2x8 LEDGER - FASTEN PER DETAIL 1/S0.303 2X LOAD BEARING EXTERIOR STUD WALL - SEE PLAN AND SCHEDULE 2X6 OUTRIGGER AT 24" O.C. MAX. ROOF SHEATHING GABLE ROOF TRUSSES SEE PLAN SEE 2/S4.310 FOR GABLE ROOF TRUSS FRAMING INFORMATION NOT SHOWN. 2X CONT. PROVIDE (4) 0.148x3" NAILS TOTAL @ EA JOIST TO LEDGER Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:10:27 PMS4.314 Framing Sections - Wood Roof Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"2 Framing Section at Front Porch 3/4" = 1'-0"1 Framing Section at Rear Porch 3/4" = 1'-0"3 Framing Section at Front Porch. No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 STAG G ER SC R EW S PER M AN U FAC TU R ER R EC O M M EN D ATIO N LTP PER SC H ED U LE(G IN STALLATIO N O N LY)SD S25500 SC R EW U PPER W ALL BO TTO M PLATE TO BLO C KIN G FLOOR TRUSS BEARING WALL TOP CHORD TRUSSTOP C H O R D BEAR IN G TR U SSFLO O R SH EATHING TO P C H O R D BEAR IN G TR U SSSC H ED U LED SC R EW SPAC IN G U PPER W ALLSH EATH IN G & TR U SSBEAR IN G / BLO C KIN G SCREW SHEAR FASTENER ASSEMBLYLOW ER W ALLSD S25300 SC R EW TH R O U G H LO W ER W ALL D O U BLE TO PPLATE M EM BER S2X BO TT / SO LE PLATEBLO C KING 2X U PPER TO P PLATELO W ER TO P PLATE:NON-FLOOR TRUSS BEARING WALLSTAGGER SC R EW S PER M AN U FAC TU R ER R EC O M M EN D ATIO N SD S25500 SC R EW U PPER W ALL BO TTO M PLATEIN TO LO W ER W ALLD O U BLE TO P PLATEUPPER W ALLFLO O R SH EATHING SC H ED U LED SC R EW SPAC IN G SCREW SHEAR FASTENER ASSEMBLY LO W ER W ALL2X BO TT / SO LE PLATE2X U PPER TO P PLATELO W ER TO P PLATE:NON-FLOOR TRUSS BEARING WALLSTAGGER SC R EW S PER M AN U FAC TU R ER R EC O M M EN D ATIO N SD S25800 SC R EW U PPER W ALL BO TTO M PLATETH R O U G H AD D 'L D O U BLEPLATE AN D IN TO LO W ER W ALL D O U BLE TO PPLATEFLO O R SH EATHING SC H ED U LED SC R EW SPAC IN G UPPER W ALLSH EATH IN G & AD D 'LD O U BLE PLATELO W ER W ALLSCREW SHEAR FASTENER ASSEMBLY (ALTERNATE ADD'L DOUBLE PLATE)( 2) R O W S STAG G ER ED W H EN R EQ U IR ED BYSC H ED U LEN AIL U PPER W ALL BO TTPLATE IN TO BLO C KIN G FLOOR TRUSS BEARING WALL TOP CHORD TRUSSTOP C H O R D BEAR IN G TR U SSFLO O R SH EATHING TO P C H O R D BEAR IN G TR U SSSC H ED U LED Q U AN TITYO F N AILS PER FO O TU PPER W ALLSH EATH IN G & TR U SSBEAR IN G / BLO C KIN G NAIL SHEAR FASTENER ASSEMBLYL O W ER W ALLN AIL BO TT BLO C KIN G M EM BER IN TO LO W ER W ALL D O U BLE TO PPLATE TO P M EM BER N AIL TO P BLO C KIN G M EM BER IN TO BO TT BLO C KIN G M EM BER N AIL LO W ER W ALL D O U BLE TO PPLATE TO P M EM BER IN TO BO TTM EM BER NON-FLOOR TRUSS BEARING WALL(2) R O W S STAG G ER ED W H EN R EQ U IR ED BYSC H ED U LEN AIL U PPER W ALL BO TTPLATE IN TO LO W ER W ALL D O U BLE TO PPLATE TO P M EM BER U PPER W ALLFLO O R SHEATH IN G SC H ED U LED Q U AN TITYO F N AILS PER FO O TNAIL SHEAR FASTENER ASSEMBLY LO W ER W ALLN AIL LO W ER W ALL D O U BLE TO PPLATE TO P M EM BER IN TO D O U BLE PLATE BO TT M EM BER NON-FLOOR TRUSS BEARING WALLFLOOR SH EATHING NAIL SHEAR FASTENER ASSEMBLY (ALTERNATE ADD'L DOUBLE PLATE)LO W ER W ALLN AIL AD D 'L D O U BLE PLATE TO PM EM BER IN TO AD D 'L D O U BLEPLATE BO TT M EM BER N AIL LO W ER W ALL D O U BLE TO PPLATE TO P M EM BER IN TO BO TTM EM BERSCHEDULED Q U AN TITYO F N AILS PER FO O TU PPER W ALLSH EATH IN G & AD D 'LD O U BLE PLATEN AIL AD D 'L D O U BLE PLATE BO TTM EM BER IN TO LO W ER W ALLD O U BLE TO P PLATE TO PM EM BER N AIL U PPER W ALL BO TT PLATEIN TO AD D 'L D O U BLE PLATE TO PM EM BER(2) R O W S STAG G ER W H EN R EQ U IR ED BY SC H ED U LEFLOOR TRUSS FASTENER ASSEMBLY DETAILS FLOOR TRUSS BEARING FLOOR TRUSS NON BEARING NAILING /1A S5.410 FLOOR TRUSS NON BEARING (ALTERNATE) SCREWS /1B S5.410 /1C S5.410 /2A S5.410 /2B S5.410 /2C S5.410 WOOD FRAME SHEAR WALL SCHEDULE -WOOD STRUCTURAL PANEL (WSP) 1,8,16,17,18,19 SHEAR WALL SCHEDULE NOTES: 1. WSP SHALL BE 7/16" THICK 3-PLY MIN. PLYWOOD OR OSB SHALL HAVE A MAXIMUM MOISTURE CONTENT OF 19% AT TIME OF FABRICATION. SEE GENERAL NOTES FOR WSP SPECIFICATIONS. 2. DOUBLE SIDED SHEAR WALLS LABELED AS CC SHALL BE INSTALLED WITH WSP BOTH SIDES OF WALL SHEATHED AND FASTENED PER SCHEDULE. 3. S WALLS SHALL BE SHEATHED WITH 7/16" STRUCTURAL 1 WSP OR 15/32" WSP W/ 0.148" DIA x 3" LONG NAILS SPACED PER SCHEDULE. 4. FIELD NAILING (NAILS @ ALL OTHER SUPPORTS) SHALL BE 12" O.C. TYPICAL WITH THE SAME NAIL SIZE AS SPECIFIED AT BOUNDARY / EDGE NAILING CONDITIONS. 5. ALL BOUNDARY / EDGE AND FIELD NAILING SHALL BE WITH 0.131"⌀x 2 1/2" LONG NAILS SPACED PER SCHEDULE. 6. ALL VERTICAL AND HORIZONTAL JOINTS SHALL BE BLOCKED AS SCHEDULED WITH BLOCKS TO MATCH WALL THICKNESS (TYPICAL). 7. ALL SHEAR WALL SILL PLATES SHALL BE 2X MIN. 8. PROVIDE (2)2X OR 3X STUDS AT ABUTTING WALL PANELS PER SCHEDULE. DOUBLE 2X STUDS SHALL BE FACE NAILED TOGETHER WITH (2) STAGGERED ROWS OF 0.148"⌀x 3" LONG NAILS SPACED @ 4" O.C. (TYPICAL). 9. EDGE DISTANCE FROM PANEL EDGES SHALL BE 1/2" MIN. AND EDGE DISTANCE FROM CONNECTING MEMBERS SHALL BE 3/8" MIN. 10. STAGGER NAILING AT ALL ADJOINING PANEL EDGES WHERE NAIL SPACING IS LESS THAN 6" O.C. 11. AT POST TENSIONED SLABS, POST-INSTALLED MECHANICAL ANCHORS SHALL BE SIMPSON TITAN-HD (ICC ESR-2713) x 5" MIN. EMBEDMENT INTO CONCRETE. CAST-IN-PLACE ANCHORS SHALL BE EMBEDDED 7" MIN. INTO CONCRETE. 12. SIMPSON MASA ANCHORS SHALL BE INSTALLED WITH STANDARD INSTALLATION AND 20% MAX. ONE-LEG UP INSTALLATION ALONG A WALL LINE (1 OF EVERY 5 MAX.) WITH ALL NAIL HOLES FILLED (TYPICAL). 13. ALLOWABLE SHEAR CAPACITY VALUES ARE BASED ON SPF STUD FRAMING. FOR DFL STUD FRAMING, THE ALLOWABLE SHEAR VALUES SHALL BE DIVIDED BY 0.92 14. CONTRACTOR SHALL APPROPRIATELY SURVEY STRUCTURAL SLABS PRIOR TO POST-INSTALLED ANCHOR INSTALLATION TO ENSURE EXISTING POST-TENSIONING TENDONS ARE NOT DAMAGED DURING ANCHOR INSTALLATION (TYPICAL). IN NO INSTANCE SHALL EXISTING POST-TENSIONING TENDONS BE DAMAGED. 15. CONTRACTOR SHALL FOLLOW ALL POST-INSTALLED ANCHOR MANUFACTURER INSTALLATION INSTRUCTIONS, RECOMMENDATIONS AND PROTOCOLS IN ADDITION TO BUILDING CODE SPECIAL INSPECTION REQUIREMENTS. 16. REFER TO SHEAR WALL END ANCHOR ELEVATIONS AND SCHEDULE FOR REQUIRED SHEAR WALL END POST / STUDS. IF NO ANCHOR IS SPECIFIED, PROVIDE (2)2X FULL HEIGHT STUDS EACH SIDE OF HOLDOWN ROD AND AT EACH END OF SHEAR WALL. FACE NAIL (2)2X STUDS TOGETHER WITH (2) ROWS OF 0.148"⌀x 3" NAILS @ 4" O.C. STAGGERED ON ALTERNATING SIDES (TYPICAL). 17. WHERE SHEAR WALLS ARE SUPPORTED BY STEEL BEAMS, PROVIDE 2X OR 3X CONTINUOUS NAILER RIPPED TO MATCH STEEL BEAM FLANGE WIDTH AND ANCHOR WITH 5/8"⌀THREADED STUDS SHOP WELDED TO BEAM TOP FLANGE @ SCHEDULED ANCHOR BOLT SPACING. 18. SHEAR FASTENER INSTALLATION SHALL MEET ONE OF THE PROVIDED ASSEMBLY DETAILS PROVIDED, SEE ACCOMPANYING DETAILS. 19. SHEAR WALL FRAMING SHALL BE 2X STUDS @ 16" O.C. MAX. REFER TO WOOD SHEAR WALL PLAN(S) FOR SHEAR WALL TYPES AND LOCATIONS. 20. NO SUBSTITUTIONS FOR SCHEDULED SHEAR WALL FRAMING OR HARDWARE WITHOUT FORMAL RFI REQUEST AND APPROVAL BY SEOR PRIOR TO CONSTRUCTION. 21. AT WALLS WITH PANELS APPLIED TO ONE FACE ONLY, PANELS MAY BE PLACED ON EITHER FACE YET MUST ATTACH DIRECTLY TO STUDS (TYPICAL). 22. SILL PLATE ANCHORAGE SHALL BE CAST-IN ANCHORS. POST-INSTALLED OR MASA ANCHORS AT CONTRACTOR'S OPTION. 23. FASTENER SPACING SPECIFIED SHALL BE BASED ON AN AVERAGE SPACING PROVIDED ALONG THE SHEARWALL LENGTH. WHERE STUDS AND OTHER OBSTRUCTIONS PREVENT THE SPECIFIED UNIFORM SPACING TO BE INSTALLED, A TIGHTER SPACING MAY BE USED PROVIDED THAT THE MINIMUM SPACING IS MAINTAINED PER TABLE BELOW. FASTNER TYPE MIN. SPACING (IN ANY SINGLE ROW)MIN. SPACING BETWEEN ROWS MIN. WOOD EDGE / END DISTANCES • CAST-IN ANCHOR BOLTS 3"N/A 1 1/2" EDGE / 5 1/2" END • POST-INSTALLED MECH. ANCHORS 5"N/A 1 1/2" EDGE / 5 1/2" END • SIMPSON MASA MUD SILL ANCHORS 4"N/A 2" END • NAILS 2 1/4"3/8"3/8" EDGE / 2 1/2" END • SIMPSON SDS25 SCREWS 3"5/8"5/8" EDGE / 3" END • SIDE CONNECTORS (LTP4)6"N/A N/A SHEAR WALL TYPE 2,3 SHEATHED FACES BOUNDARY / EDGE NAILING4,5,9,10 BLOCKED EDGES 6,8 SILL PLATE 7,22 ANCHORAGE TO CONCRETE 11,12,23 CAST-IN ANCHOR BOLTS (ASTM F1554 GR. 36) NAILS A 1 NAILS / FT (0.148"⌀X 3 1/4") BOTTOM PLATE TO TOP PLATE CONNECTION 23 POST-INSTALLED MECH. ANCHORS 14,15 (ICC ESR-2713) SIMPSON MASA MUD SILL ANCHORS (ICC ESR-2555) B C CC D S 2" O.C.(2) 2X 5/8"⌀@ 18" O.C.5/8"⌀@ 18" O.C.12" O.C.5 NAILS/FT -2 ROWS 1 1 2 1 1 3" O.C. 4" O.C. 4" O.C. 6" O.C. 2" O.C. 2X 2X 2X 2X (2) 2X 5/8"⌀@ 24" O.C.5/8"⌀@ 24" O.C.16" O.C. 5/8"⌀@ 33" O.C.5/8"⌀@ 33" O.C.21" O.C. 5/8"⌀@ 16" O.C.5/8"⌀@ 16" O.C.10" O.C. 5/8"⌀@ 48" O.C.5/8"⌀@ 48" O.C.31" O.C. 5/8"⌀@ 18" O.C.5/8"⌀@ 18" O.C.11" O.C. 4 NAILS/FT -1 ROW 3 NAILS/FT -1 ROW 6 NAILS/FT -1 ROW 2 NAILS/FT -1 ROW 6 NAILS/FT -1 ROW WD10.0 WOOD SHEAR WALL SCHEDULE (WSP) FOR WIND AND SEISMIC DESIGN CATEGORY A-C: SCREWS SIMPSON LTP4 SIMPSON SDS25 SCREWS STAGGERED 6" O.C.10" O.C. 13" O.C. 8" O.C. 25" O.C. 8" O.C. 17" O.C. 8" O.C. 10" O.C. 5" O.C. 16" O.C. 5" O.C. ALLOWABLE SHEAR CAPACITY (PLF) SEISMIC 13 ALLOWABLE SHEAR CAPACITY (PLF) WIND 13 588 823 450 630 349 489 698 978 239 335 708 901 SIDE CONNECTIONS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:20 PMS5.410 Wood Shear Wall Schedule Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 2A 2B 2C 1A 1B 1C No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 DEMISING WALL (2 SIDES) FIRE SEPARATIONINTERSECTING WALL EXTERIOR WALL2' - 0"OPP HANDS5.413 1 . OPP HAND DEMISING WALL (1 SIDE) SHEAR WALL DIAGRAM -EXTERIOR CONDITIONS 3'-0" MIN. MIN DISTANCE FROM END OF COMPRESION MEMBER AND FACE OF OPENING ANCHOR ROD / COMPRESSION POST SCHEMATIC 3'-0" MIN FOR ANCHOR ROD ANCHORAGE AT FOUNDATION SEE SHEET FOR ANCHOR ROD ANCHORAGE AT PODIUM SEE SHEET DEMISING WALL (2 SIDES) FIRE SEPERATIONINTERSECTING WALL CORRIDOR WALL OPP HAND OPP HAND OPP HAND DEMISING WALL (1 SIDE) S5.413 1 . SHEAR WALL DIAGRAM -INTERIOR CONDITIONS 3'-0" MIN MIN DISTANCE FROM END OF COMPRESION MEMBER AND FACE OF OPENING ANCHOR ROD / COMPRESSION POST SCHEMATIC FOR ANCHOR ROD ANCHORAGE AT FOUNDATION SEE SHEET FOR ANCHOR ROD ANCHORAGE AT PODIUM SEE SHEET WOOD SHEAR WALL SCHEDULE NOTES: 1. RTUD AND ATUD BEARING PLATES SHALL BE PROVIDED BY SIMPSON STRONG-TIE BASED ON WALL WIDTH, AND TAKE-UP DEVICE CAPACITY AT EACH LEVEL. 2. RTUD AND ATUD TAKE-UP DEVICES ARE MANUFACTURED BY SIMPSOM STRONG-TIE CONFORMING TO ICC ESR-2320. ALTERNATIVE TAKE-UP DEVICES MAY BE CONSIDERED PROVIDED DATA IS SUBMITTED FOR REVIEW BY THE EOR PRIOR TO CONSTRUCTION. IN ADDITION, PROPOSED ALTERNATES SHALL NOT EXCEED THE MAXIMUM DEFLECTION AT ALLOWABLE LOAD OF SCHEDULED TAKE-UP DEVICES PER ICC ESR-2320. 3. STANDARD AND TRANSITION HOLD-DOWN ROD COUPLERS SHALL CONFIRM TO SIMPSON ATS-C OR ATS-HSC COUPLER NUTS BASED ON SCHEDULED ROD SIZE, SPECIFIED YEILD STRENGTH AND SPECIFIED TENSILE STRENGTH (TYPICAL) 4. THE MAXIMUM ACCUMULATION OF VERTICAL DISPLACEMENT, INCLUDING ROD ELONGATION, BEARING PLATE-GRAIN DEFORMATION, TAKE UP / SHRINKAGE COMPENSATIONG DEVICES, AND OTHER COMPONENTS OF THE HOLD-DOWN SYSTEM HAS BEEN LIMITED TO A MAXIMUM OF 0.2" WHEN CONSIDERING MAXIMUM ALLOWABLE TENSION LOADS FOR EACH SCHEDULED ROD SIZE. WOOD SHEAR WALL COMPRESSION END MEMBER TABLE FOOTNOTES: 1. SEE ELEVATIONS FOR GENERAL LAYOUT AND FLOOR FRAMING DETAILS FOR ADDITIONAL INFORMATION. 2. AT SHEAR WALL LOCATIONS WITH FLOOR/ROOF TRUSSES PERPENDICULAR TO WALL, TOP CHORD BEARING TRUSSES REQUIRE SOLID BLOCKING AND BOTTOM CHORD BEARING TRUSSES REQUIRE TRUSS BLOCKS BETWEEN ALL TRUSSES. 3. AT SHEAR WALL LOCATIONS WITH FLOOR / ROOF TRUSSES PARALLEL TO WALL, WALL SHALL EXTEND TO BOTTOM OF FLOOR SHEATHING AT TOP CHORD BEARING TRUSSES AND EITHER A DRAG TRUSS IS PROVIDED ABOVE THE WALL OR THE WALL SHALL EXTEND TO BOTTOM OF SHEATHING AT BOTTOM CHORD BEARING TRUSSES. 4. TJI JOISTS INSTALLED PERPENDICULAR TO SHEAR WALLS SHALL BE PROVIDED WITH SOLID BLOCKING OR RIMBOARD; AT LOCATIONS WHERE TJI JOISTS ARE INSTALLED PARALLEL TO SHEAR WALLS, EITHER A TJI IS INSTALLED DIRECTLY OVER THE WALL OR THE WALL IS EXTENDED TO BOTTOM OF FLOOR/ROOF SHEATHING. 5. ALL STUDS AND POSTS SHALL BE #2 GRADE OR BETTER. REFER TO POST SCHEDULE FOR POSTS THAT REQUIRE HIGHER GRADE MATERIAL (TYPICAL). 6. ALL RODS SHALL BE SIMPSON STRONG ROD ATR, ATS-HSR, OR ATS-HSSR AS NOTED IN THE SCHEDULE. 7. AT COMPRESSION END MEMBER TABLE ENTRIES WITH N-XX OR N-XXX, THE N REPLACES THE (2)2X END MEMBERS WITH AN 'N' POST PER THE COMPRESSION END MEMBER SCHEDULE (TYPICAL). 8. AS AN ALTERNATE TO MULTIPLE STUD PACKS, SOLID POSTS ARE ACCEPTABLE PER THE FOLLOWING SCHEDULE: • (4) 2X4 = 4X8 • (4) 2X6 = 6X8 NAILING AT ADDED STUDS SHALL BE SPACED AT 12" O.C. MAX. COMPRESSION POST STUD PACK NAILING 1 3"6" 9" SHEAR WALL END (2) 2X END MEMBER - SEE SHEAR WALL ANCHORAGE DETAILS 2 ANCHOR ROD -SEE SCHEDULE THIS SHEET INTERIOR COMPRESSION POST STUD PACK OR SOLID POST / POST GROUP -SEE SCHEDULE THIS SHEET NOTE: 1. AT COMPRESSION POST AND END MEMBER STUD PACKS, SHEARWALL EDGE/ BOUNDARY NAILING TO CLOSEST (2) STUDS EACH SIDE OF ROD SHALL BE EDGE NAILED PER SHEAR WALL SCHEDULE MULTIPLIED BY TOTAL NUMBER OF STUDS IN SCHEDULED STUD PACK, BUT NOT TO EXCEED 12" O.C. NAILING AT SOLID POSTS SHALL BE EDGE NAILED AT CENTERLINE OF EACH POST AND AT (2) END MEMBER STUDS (TYPICAL) 2. AT INSTANCES END MEMBER STUDS ARE LOCATED AT CORNER / INTERSECTION STUD PACKS, END MEMBERS ARE COMBINED WITH CORNER / INTERSECTION STUD PACKS PER ANCHORAGE DETAILS. END MEMBER STUD PACK NAILING 1,2 COMPRESSION END MEMBER SCHEDULE (DFL #2 UNO) A B C D E MARK MEMBER F G H J K L M N P Q R S T 4X6 4X8 4X10 4X12 6X6 6X8 6X12 6X10 6X10 #1 6X12 #1 3.5X7.5 PSL 3.5X9.5 PSL 3.5X11.875 PSL 4X12 #1 3.5X14 PSL 3.5X3.5 PSL 3.5X16 PSL 6X14 #1 MARK MEMBER WD11.0 Wood Shear Wall Compresion End Member Table (SPF / SYP -WIND / SEISMIC A-C) LEVELS 2X4 2X6 L5 L4 L3 L2 L1 1 ATR3/8 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" 1 11 1 1 10'-2" 2X4 2X6 1 1 11 1 1 11 2 1 12 2 1 1 1 11'-2" 2X4 2X6 1 1 2 1 2 1 3 1 1 2 12'-2" 2X4 2X6 1 1 2 1 3 1 4 1 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 2 ATR1-1/8 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" CC 2CC DD DD 10'-2" 2X4 2X6 3 3 2CC DD 3 2CC DD 3 2CC JJ 3 JJ JJ 11'-2" 2X4 2X6 3 3 JJ 3 JJ 3 JJ 3 S S 12'-2" 2X4 2X6 4 4 S 4 S 4 T 4 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 1 ATR1/2 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" 1 11 1 1 10'-2" 2X4 2X6 1 1 11 2 1 12 3 1 12 3 1 2 2 11'-2" 2X4 2X6 1 1 3 1 4 1 4 1 2 3 12'-2" 2X4 2X6 1 1 4 1 5 1 6 1 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 3 ATR1-1/4 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" DD 3DD JJ JJ 10'-2" 2X4 2X6 4 4 3DD JJ 4 3DD JJ 4 3DD JJ 4 T T 11'-2" 2X4 2X6 4 4 T 4 T 4 T 4 QQ QQ 12'-2" 2X4 2X6 5 5 QQ 5 QQ 5 QQ 5 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 1 ATR5/8 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" 2 12 3 3 10'-2" 2X4 2X6 1 1 12 3 1 13 4 1 13 4 1 3 4 11'-2" 2X4 2X6 1 1 4 1 5 1 6 1 4 5 12'-2" 2X4 2X6 1 1 5 1 6 1 J 1 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 4 ATR1-3/8 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" JJ 4JJ T T 10'-2" 2X4 2X6 5 5 4JJ T 5 4JJ T 5 4JJ T 5 11'-2" 2X4 2X6 RR RR 12'-2" 2X4 2X6 6 6 RR 6 RR 6 RR 6 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 1 ATR3/4 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" 3 13 4 4 10'-2" 2X4 2X6 1 1 13 5 1 14 5 1 15 6 1 6 6 11'-2" 2X4 2X6 1 1 6 1 J 1 J 1 J J 12'-2" 2X4 2X6 1 1 J 1 CC 1 CC 1 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 ATR1-1/2 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2"10'-2" 2X4 2X6 11'-2" 2X4 2X6 G G G G G SS SS 12'-2" 2X4 2X6 L L SS L SS L SS L LEVELS 2X4 2X6 L5 L4 L3 L2 L1 1 ATR7/8 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" 5 15 6 6 10'-2" 2X4 2X6 1 1 15 6 1 15 J 1 16 J 1 J J 11'-2" 2X4 2X6 1 1 J 1 CC 1 CC 1 CC CC 12'-2" 2X4 2X6 2 2 CC 2 DD 2 JJ 2 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 GG ATS-HSSR10 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" SS GGSS SS SS 10'-2" 2X4 2X6 GG GG GGSS SS GG GGSS SS GG GGSS SS GG RRR RRR 11'-2" 2X4 2X6 GG GG RRR GG RRR GG RRR GG SSS SSS 12'-2" 2X4 2X6 KK KK SSS KK SSS KK SSS KK LEVELS 2X4 2X6 L5 L4 L3 L2 L1 1 ATR1 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" J 1J CC CC 10'-2" 2X4 2X6 2 2 1J CC 2 1J CC 2 1J CC 2 DD DD 11'-2" 2X4 2X6 2 2 DD 2 DD 2 JJ 2 JJ JJ 12'-2" 2X4 2X6 2 2 JJ 2 JJ 2 JJ 2 LEVELS 2X4 2X6 L5 L4 L3 L2 L1 ATS-HSR12 WOOD SHEAR WALL COMPRESION END MEMBER TABLE STUD / POST CLEAR HEIGHT 9'-2" SSS SSS 10'-2" 2X4 2X6 SSS SSS SSS 11'-2" 2X4 2X6 MM MM MM MM MM PTTT 12'-2" 2X4 2X6 SSS SSS SSS SSS SSS LM LM LM LM LM TTT TTT TTT TTT TTT PTTT PTTT PTTT PTTT QQ QQ QQ QQ QQ 5 5 5 5 5 RR RR RR RR RR 6 6 6 6 6 6 6 6 6 6 QQ QQ QQ QQ QQ QQ QQ QQ QQ QQ LL LL LL LL LL MM MM MM MM MM SHEARWALL DIAGRAM - 4 STORY WSW-4 WSW-5 WSW-6 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 C ATR 3/4 ATUD 6-2 1 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B D ATR 5/8 ATUD 6-2 D ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B C ATR 5/8 ATUD 6-2 C ATR 1/2 D ATR 1/2 D ATR 3/8 ATUD 6-2 ATUD 6-2 RTUD3B SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:26 PMS5.411 Wood Shear Wall Hold-Downs / Comp Post Schedule - ATR / Rod System Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 SC H ED U LED C O M PR ESSIO N EN D M EM BER SC H EDULED AN C H O R RO DCOUPLER SC H EDULED TAKE-UP DEVICEBEARING PLATESO LID BLO C KIN G BETW EEN TR U SSES (TYPIC AL)SC H EDULED AN C H O R RO D SC H ED U LED C O M PR ESSIO N EN D M EM BERSCHEDULED AN C H O R RO D CO U PLER BEARING PLATESC H EDULED TAKE-UP DEVICE1.BRIDGE BLOCK TO BE USED CONTRACTORS OPTION AND AT CONDITIONS WHERE TRUSS BEARING INTERFERES WITH SCHEDULED ANCHOR ROD TAKE-UP DEVICE. NOTE:SC H ED U LED TAKE-U P D EVIC EO N D O U BLE TO P PLATE /BR ID G E BLO C KSC H ED U LED C O M PR ESSIO N EN D M EM BER1 CO U PLER SC H EDULED AN C H O RSTEEL BEAM S5.412 2 . B E A R IN G P L A T E S C H E D U L E D T A K E -U P D E V IC E S C H E D U L E D C O M P R E S S IO N E N D M E M B E R S C H E D U L E D A N C H O R R O D A D D IT IO N A L C R IP P L E S T U D S A T B R ID G E B L O C K (1 E A S ID E )1 ,2BRIDGE B L O C K 4 NOTE: 1. CRIPPLE STUDS SHALL BE 2X MEMBERS STICHED NAILED PER FASTENING SCHEDULE WITH A MAX NAIL SPACING OF 6" O.C. (CRIPPLE STUDS MAY BE NAILED TO FULL HEIGHT STUDS FROM EITHER SIDE.) 2. CRIPPLE STUDS TO BE (TOP LEVEL ONLY): • 2X4 WALL = (2) 2X4 • 2X6 WALL = (1) 2X6 3. DO NOT NAIL BRIDGE BLOCK TO CRIPPLE STUDS. 4. BRIDGE BLOCK TO BE: • 2X4 WALL = 4X6 #1 • 2X6 WALL = 6X6 #1 A D D O N E T O E N A IL E A E N D O F B R ID G E B L O C K IN T O T O P C R IP P L E S T U D S 3 . 2X CORNER STUDS SPACING SCHEDULEDSTUD SPACINGSCHEDULEDSHEAR WALL.9" EQEQ9"SHEAR WALL EQEQSHEAR WALL EDGE NAILING SCHEDULED SHEAR WALL END ANCHOR (SHORTEST WALL) SCHEDULED SHEAR WALL END ANCHOR STUD / ANCHOR STEEL BEAM / STUD / ANCHORSCHEDULED COMPRESSION POST SCHEDULED COMPRESSION POST (2) 2X END POST MEMBER (2) 2X END POST MEMBER SHEAR WALL FIELD NAILING (TYPICAL) 11 1/4"1' - 6"STUD SPACINGSCHEDULED...EQEQSTUD SPACINGSCHEDULEDSHEAR WALLSHEAR WALL 2' - 0"9"EQEQSCHEDULED SHEAR WALL END ANCHOR 2X CORNER STUDS SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL SCHEDULED SHEAR WALL END ANCHOR SCHEDULED COMPRESSION POST .SCHEDULED COMPRESSION POST EXTERIOR 9"SHEAR WALL FIELD NAILING (TYPICAL) COMBINED CORNER / (2) 2X END POST MEMBER (2) 2X END POST MEMBER STUD / ANCHORSTUD / ANCHOR 1' - 2" STUD SPACING SCHEDULEDSTUD SPACINGSCHEDULED...EQEQSTUD SPACINGSCHEDULEDSHEAR WALLSHEAR WALL 2' - 0"9"EQEQSCHEDULED SHEAR WALL END ANCHOR 2X CORNER STUDS SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED SHEAR WALL END ANCHOR SCHEDULED COMPRESSION POST .SCHEDULED COMPRESSION POST EXTERIOR 9"SHEAR WALL FIELD NAILING (TYPICAL) (2) 2X END POST MEMBER (2) 2X END POST MEMBER STUD / ANCHORSTUD / ANCHOR AT EXTERIOR W/ OUT SHEAR WALL AT EXTERIOR SHEAR WALL EQ EQ EQ EQ SCHEDULED COMPRESSION POST SCHEDULED SHEAR WALL END ANCHOR SHEAR WALL BOUNDARY / EDGE NAILING9" STUD SPACING SCHEDULED SCHEDULED COMPRESSION POST SHEAR WALL BOUNDARY / EDGE NAILING STUD SPACING SCHEDULED 9"STUD / ANCHOR(2) 2X END POST MEMBER (2) 2X END POST MEMBER SCHEDULED SHEAR WALL END ANCHOR (2) 2X END POST MEMBER STUD SPACING SCHEDULEDSTUD SPACINGSCHEDULED...EQEQSHEAR WALLSHEAR WALL 1' - 6"2X CORNER STUDS SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL BOUNDARY / EDGE NAILING (TYPICAL) SCHEDULED SHEAR WALL END ANCHOR .SCHEDULED COMPRESSION POST CORRIDOR SIDE SHEAR WALL FIELD NAILING (TYPICAL) STUD / ANCHORSTUD / ANCHOR AT CORRIDOR W/ SHEAR WALL AT CORRIDOR W/ OUT SHEAR WALLSTUD SPACINGSCHEDULED...EQEQ2X CORNER STUDS (COMBINED W/ (2) 2X END POST MEMBERS).CORRIDOR SIDE 9"1' - 3 3/4" 4 1/2"11 1/4"EQ EQ STUD SPACING SCHEDULED STUD SPACING SCHEDULED SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL BOUNDARY / EDGE NAILING (2) 2X END POST MEMBER STEEL BEAM EQ EQ STUD SPACINGSCHEDULEDSTEEL BEAM / STUD / ANCHOR9"STEEL BEAM BELOW STEEL BEAM BELOW STUD / ANCHORSTUD / ANCHOR STEEL BEAM STEEL BEAM BELOW SHEAR WALLSHEAR WALL SHEAR WALL FIELD NAILING (TYPICAL) SHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED SHEAR WALL END ANCHOR (2) 2X END POST MEMBER STEEL BEAM BELOW STUD SPACINGSCHEDULED9"STEEL BEAM / STUD / ANCHOR1' - 6"SHEAR WALL BOUNDARY / EDGE NAILING (TYPICAL) SCHEDULED COMPRESSION POST AT CORRIDOR W/ SHEAR WALLSTUD SPACINGSCHEDULED...EQEQ2X CORNER STUDS .CORRIDOR SIDE 9"9" EQ EQEQEQ STUD SPACING SCHEDULED STUD SPACING SCHEDULED SHEAR WALL BOUNDARY / EDGE NAILING STUD / ANCHORSTUD / ANCHOR STEEL BEAM SHEAR WALLSHEAR WALL SHEAR WALL FIELD NAILING (TYPICAL) SHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED SHEAR WALL END ANCHOR (2) 2X END POST MEMBER STEEL BEAM BELOW STUD SPACINGSCHEDULED9"STEEL BEAM / STUD / ANCHOR1' - 6"SHEAR WALL BOUNDARY / EDGE NAILING (TYPICAL) SCHEDULED COMPRESSION POST STEEL COLUMN BELOW 1' - 6"1' - 6" . 2X CORNER STUDS SPACING SCHEDULEDSPACINGSCHEDULEDSHEAR WALL.9" EQEQ SHEAR WALL BOUNDARY / EDGE NAILING STUD / ANCHORSCHEDULED COMPRESSION POST SCHEDULED SHEAR WALL END ANCHOR (2) 2X END POST MEMBER STUD SPACING SCHEDULEDSTUD SPACINGSCHEDULED...9"EQEQBEAM / STUD / ANCHOR SCHEDULED SHEAR WALL END ANCHOR 2X "T" INTERSECTION STUDS TO MATCH STUD / SHEAR WALL SCHEDULE SHEAR WALL SHEAR WALL SHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED COMPRESSION POST (2) 2X END POST MEMBER SHEAR WALL FIELD NAILING (TYPICAL) SHEAR WALL FIELD NAILING (TYPICAL) STEEL BEAM . 9" EQEQ BEAM / STUD / ANCHORSHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED SHEAR WALL END ANCHOR TRIMMER / COMBINED (2) 2X END POST MEMBER SHEAR WALL KING POST / COMBINED (2) 2X END POST MEMBER SPACING SCHEDULED SHEAR WALL FIELD NAILING (TYPICAL) SCHEDULED COMPRESSION POST STEEL BEAM . 9" EQEQ BEAM / STUD / ANCHORSHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED SHEAR WALL END ANCHOR SHEAR WALL SPACING SCHEDULED (2) 2X END POST MEMBER SHEAR WALL FIELD NAILING (TYPICAL) SCHEDULED COMPRESSION POST STEL BEAM STUD SPACING SCHEDULEDSTUD SPACINGSCHEDULED...9"EQEQSTUD SPACINGSCHEDULEDSHEAR WALLSHEAR WALL 2X "T" INTERSECTION STUDS TO MATCH STUD / SHEAR WALL SCHEDULE SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL RIPPED 2X AS REQUIRED SCHEDULED SHEAR WALL END ANCHOR EXTERIOR SHEAR WALL FIELD NAILING (TYPICAL).SHEAR WALL FIELD NAILING (TYPICAL) (2) 2X END POST MEMBER (2) 2X END POST MEMBER SHEAR WALL BOUNDARY / EDGE NAILING SCHEDULED COMPRESSION POST 1' - 6"STEEL BEAM BELOWSTEEL COLUMN BELOW (WHERE OCCURS) STUD / ANCHORSTUD / ANCHOR STEEL BEAM NOTE: SHEATHING MAY BE APPLIED TO JOINT SIDE OF DEMISING WALL STUD SPACING SCHEDULEDSTUD SPACINGSCHEDULED...9"EQEQSTUD SPACINGSCHEDULEDSHEAR WALL SHEAR WALL 1' - 0"9"EQEQSCHEDULED SHEAR WALL END ANCHOR 2X "T" INTERSECTION STUDS TO MATCH STUD / SHEAR WALL SCHEDULE SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL (WHERE OCCURS) RIPPED 2X AS REQUIRED SCHEDULED SHEAR WALL END ANCHOR CORRIDOR SIDE SHEAR WALL FIELD NAILING (TYPICAL) (2) 2X END POST MEMBER (2) 2X END POST MEMBER .SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL FIELD NAILING (TYPICAL) STUD / ANCHORSTUD / ANCHOR STUD SPACING SCHEDULED ...9"EQEQSTUD SPACINGSCHEDULEDSHEAR WALL 2X "T" INTERSECTION STUDS TO MATCH STUD / SHEAR WALL SCHEDULE SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL (WHERE OCCURS) RIPPED 2X AS REQUIRED SCHEDULED SHEAR WALL END ANCHOR EXTERIOR .STUD SPACINGSCHEDULEDSHEAR WALL FIELD NAILING (TYPICAL) SHEAR WALL FIELD NAILING (TYPICAL) STUD / ANCHORSTUD / ANCHOR (2) 2X END POST MEMBER STUD SPACING SCHEDULED ...9"EQEQSTUD SPACINGSCHEDULEDSHEAR WALL 2X "T" INTERSECTION STUDS TO MATCH STUD / SHEAR WALL SCHEDULE SHEAR WALL BOUNDARY / EDGE NAILING SHEAR WALL (WHERE OCCURS) RIPPED 2X AS REQUIRED SCHEDULED SHEAR WALL END ANCHOR CORRIDOR SIDESTUD SPACINGSCHEDULED.SHEAR WALL FIELD NAILING (TYPICAL) STUD / ANCHORSTUD / ANCHOR (2) 2X END POST MEMBER Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:32 PMS5.412 Wood Shear Wall Hold-Down Details - ATR / Rod System Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1" = 1'-0"1 Shear Wall Hold-Down Schematic 1" = 1'-0"2 Shear Wall Anchor Anchorage 3/4" = 1'-0"3 Shear Wall Anchorage - Corner 3/4" = 1'-0"13 Exterior Exterior Shear Wall Anchorage - Fire Wall 3/4" = 1'-0"12 Interior Shear Wall Anchorage - Fire Wall at Corridor 3/4" = 1'-0"4 Exterior Shear Wall Anchorage - Corner 3/4" = 1'-0"5 Shear Wall Anchorage - Tee 3/4" = 1'-0"6 Exterior Shear Wall Anchorage - Wall Opening 3/4" = 1'-0"7 nterior Shear Wall Anchorage - End of Wall 3/4" = 1'-0"8 Exterior Shear Wall Anchorage - Demising Wall 2 Sides 3/4" = 1'-0"9 Interior Shear Wall Anchorage - Demising Wall 2 Sides 3/4" = 1'-0"10 Exterior Shear Wall Anchorage - Demising Wall 1 Side 3/4" = 1'-0"11 Interior Shear Wall Anchorage - Demising Wall 1 Side No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 OPENING WIDTH 2'-0" MAX OPENING DEPTH1' - 2" MAXCS14 X 5'-0" OVER 2X BLOCKING CENTERED ON OPENING (1) 2X WALL STUD CENTERED WITHIN OPENING WIDTH (1) 2X WALL STUD CENTERED WITHIN OPENING WIDTH OPENING WIDTH 1' - 2 1/2" MAX CS16 STRAPS EA. SIDE OF OPENING (EXTEND 11" MIN. PAST EDGE OF OPENING) PROVIDE 2X BLOCKING AS REQUIRED OPENING WIDTH 2'-0" MAX CS14 X 5'-0" OVER 2X BLOCKING CENTERED ON OPENING (TOP AND BOTTOM FO OPENING) (1) 2X WALL STUD CENTERED WITHIN OPENING WIDTH (2) 2X WALL STUDS EA SIDE OF OPENING STICHED TOGETHER PER FASTENING SCHEDULE (TYPICAL)11" (TYP)11" MINOPENING HEIGHT1' - 6" MAX11" (TYP)OPENING AT TOP OF SHEAR WALL 1'-6" HIGH MAX OPENING IN SHEAR WALL 4'-0" HIGH HEIGHT OPENING IN SHEAR WALL PROVIDE 2X BLOCKING AS REQUIRED PROVIDE 2X BLOCKING AS REQUIRED 4X8 BLOCK AT 2X4 WALLS 6X8 BLOCK AT 2X6 WALLS (1) 2X WALL STUD CENTERED WITHIN OPENING WIDTH CS14 X 8'-0" EA. SIDE OF OPENING NOTE: 1. ALL PANEL EDGES AT PERIMETER OF OPENINGS TO BE NAILED PER EDGE NAILING IN SHEAR WALL SCHEDULE SLOT DECK AS REQUIRED FOR STRAP TO PASS THROUGH SLOT DECK AS REQUIRED FOR STRAP TO PASS THROUGH (1) 2X WALL STUD CENTERED WITHIN OPENING WIDTH 4X BLOCKING ABOVE WALL BOTT PLATE FASTENED TO WALL STUDS W/ (2) SDS25600 SPACED AT 3" O.C. CS14 X 5'-0" STRAP CENTERED ON OPENING EA. SIDE TO EXTEND THROUGH FLOOR SHEATHING Scale Date Drawn By Checked By Project Number 3/4" = 1'-0"3/18/2026 9:19:36 PMS5.413 Wood Shear Wall Typical Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"1 Temporary and Permanent Openings In Wood Shear Walls No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 BEAM DEPTH( 2' - 0" MIN)SCHEDULED ADDITIONAL REINFORCEMENT BEAM DEPTH( 2' - 0" MIN)PROJEMBEDBENTTYPE 2 BEAM WIDTH DESIGNED GRADE BEAM REINFORCEMENT DESIGNED GRADE BEAM REINFORCEMENTBEAM WIDTH TYPE 1 COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT PROJEMBEDBENTBEAM DEPTH( 2' - 0" MIN)SCHEDULED ADDITIONAL REINFORCEMENT TYPE 3 BEAM WIDTH DESIGNED GRADE BEAM REINFORCEMENT COUPLER SCHEDULED ANCHOR RODSCHEDULED SIMPSON BLOCK CONNECTOR COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT 5/16"PROJCENTERED ON ANCHOR WIDEN GRADE BEAM TO 5' - 0" SQ PL1X8X0'-8" INSTALLED DIRECTLY ABOVE GRADE BEAM BOTT REINFORCEMENT PROVIDE #5 AT 10" O.C. EA. WAY IN ADDITION TO SCHEDULED REINFORCEMENT NOTE:AT NEAR EDGE CONDITION, 5'-0" SQ WIDENED GRADE BEAM TO START AT FACE OF STEM WALL. DOWEL ALL ADDITIONAL REINF INTO STEM WALL NOTE: AT INTERIOR CONDITONS AT END OF GRADE BEAM, SEE DETAIL AT INTERIOR CONDITONS AT INTERSECTION OF GRADE BEAMS, SEE DETAIL /3 S5.414 /5 S5.414 ANCHOR ROD ATR1/2 SHEAR WALL END ANCHOR ROD ANCHORAGE SCHEDULE NOTE: 1. SEE SHEAR WALL BRACING PLAN FOR SHEAR WALL END ANCHORAGE ROD 2. SEE ANCHOR ROD / ANCHOR DETAILS FOR ANCHOR REINFORCEMENT 3. WHEN SCHEDULED ANCHOR IS LARGER THAN SCHEDULED ROD, USE SIMPSON REDUCING COUPLER 4. SEE ANCHORAGE DIAGRAM TO DETERMINE ANCHOR LOCATION FOR EDGE, NEAR EDGE, INTERIOR, AND CORNER CONDITIONS. 5. FOR ANCHOR BOLTS INSTALLED AT STEPS IN FOUNDATION, SEE DETAIL 6. SSTB ANCHORS TO HAVE 7" PROJECTION (PROJ) FROM TOP OF SLAB, SB AND PAB ANCHORS TO HAVE 6" PROJECTION (PROJ) FROM TOP OF SLAB (TYPICAL UNO) 7. ALL PAB ANCHORS AT STEP IN SLAB TO BE SCHEDULED PAB ANCHOR LENGTH PLUS STEP HEIGHT ROUNDED UP TO NEXT 6" NOMINAL LENGTH OF 24", 30", OR 36". IF LONGER LENGTH IS REQUIRED, A COUPLER AND SCHEDULED ROD MAY BE USED TO EXTEND ANCHOR BOLT UP FOR REQUIRED 6" PROJECTION ABOVE UPPER SLAB. EMBEDMENT FOR PAB ANCHOR TO BE SCHEDULED PAB LENGTH MINUS 7". ATR5/8 ATR3/4 ATR7/8 ATR1 ATR1-1/8 ATR1-1/4 ATR3/8 INTERIOR LOCATION NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR SLAB EDGE NEAR EDGE CORNER EMBEDDED ROD ANCHORAGE ANCHOR ROD ATR1/2 ATR5/8 ATR3/4 ATR7/8 ATR1 ATR1-1/8 ATR1-1/4 ATR3/8 ADDITIONAL REINFORCEMENT NA NA NA NA NA NA NA NA NA NA ANCHORAGE TYPE / DETAIL TYPE 1 - TYPE 1 - TYPE 1 - TYPE 1 - TYPE 1 - TYPE 1 - LOCATION (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. ANCHOR BOLT / BLOCK ANCHOR SB7/8X24 SSTB24L SSTB20L SSTB16L PAB4-18 PAB4-18 PAB4-18 PAB4-18 SSTB24L SSTB20L SSTB16L PAB5-18 PAB5-18 TYPE 1 - PAB7-24 PAB7-24 PAB6-18 PAB6-18 SB7/8X24 SB7/8X24 SB7/8X24 SB1X30 SB1X30 PAB8-24 PAB8-24 PAB9-24 PAB9-24 SBC10H SBC10H PAB10-24 PAB10-24 SBC10H SBC10H TYPE 1 - TYPE 1 - TYPE 1 - TYPE 1 - TYPE 1 - NA TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 2 - TYPE 3 - TYPE 3 - TYPE 2 - TYPE 2 - TYPE 3 - TYPE 3 - (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. NA (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. (2) #4 X 8'-0" (2) #4 X 8'-0" (BENT AS NEEDED) (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. (2) #4 X 8'-0" (2) #4 X 8'-0" (BENT AS NEEDED) NA (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. (4) #5X8'-0"(T) / (2) #5X8'-0"(B) W/ # 3 STIRRUPS @ 12" O.C. NA NA (2) #5X8'-0"(T) W/ # 3 STIRRUPS @ 12" O.C. (2) #5X8'-0"(T) W/ # 3 STIRRUPS @ 12" O.C. NA /7 S5.414 ATR1-3/8 INTERIOR NEAR EDGE CORNER ATR1-3/8 SBC11H SBC11H SBC11H SBC11H TYPE 3 - TYPE 3 - TYPE 3 - TYPE 3 - (4) #5X10'-0"(T) / (2) #5X10'-0"(B) W/ (2)#3 STIRRUPS @ 10" O.C. (4) #5X10'-0"(T) / (2) #5X10'-0"(B) W/ (2)#3 STIRRUPS @ 10" O.C. (2) #4 X 8'-0" (2) #4 X 8'-0" (BENT AS NEEDED) ATR1-1/2 INTERIOR NEAR EDGE CORNER ATR1-1/2 SBC12H SBC12H SBC12H SBC12H TYPE 3 - TYPE 3 - TYPE 3 - TYPE 3 - (4) #5X12'-0"(T) / (2) #5X12'-0"(B) W/ (2) #3 STIRRUPS @ 10" O.C. (4) #5X12'-0"(T) / (2) #5X12'-0"(B) W/ (2)#3 STIRRUPS @ 10" O.C. (2) #4 X 8'-0" (2) #4 X 8'-0" (BENT AS NEEDED) (2) #5X6'-0"(T) W/ # 3 STIRRUPS @ 12" O.C. (2) #5X6'-0"(T) W/ # 3 STIRRUPS @ 12" O.C. SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR SLAB EDGE NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 /2 S5.414 /4 S5.414 /1 S5.414 /1 S5.414 LOCATION INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR SLAB EDGE NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER INTERIOR NEAR EDGE CORNER SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE SLAB EDGE ALT. POST- INSTALLED EPOXY 6" EMBEDMENT 6" EMBEDMENT 7" EMBEDMENT 7" EMBEDMENT 8" EMBEDMENT 8" EMBEDMENT 10" EMBEDMENT N/A 12" EMBEDMENT N/A 14" EMBEDMENT N/A N/A N/A N/A N/A N/A N/A N/A N/A (1) (4) (6,7)(5) (4) STUD / ANCHOR SLAB EDGE ANCHOR AT EDGE ANCHOR NEAR EDGE ANCHOR AT INTERIOR STUD / ANCHOR S5.414 .1_______ S5.414 .2_______ ANCHOR AT CORNER EXTEND GRADE BEAM 2' - 0" MIN PAST ANCHOR S5.414 .4_______ ANCHOR AT INTERIOR (GRADE BEAM INTERSECTION) ANCHOR AT INTERIOR (AT END OF GRADE BEAM) STEM WALL EQ EQ SCHEDULED ADDITIONAL REINFORCEMENT WHERE OCCURS ANCHOR LOCATION DIAGRAM SCHEDULED ADDITIONAL REINFORCEMENT WHERE OCCURS (HOOK BARS AT END OF GRADE BEAM) EQ EQ FACE OF BRICK LEDGE WHERE OCCURS SCHEDULED ADDITIONAL REINFORCEMENT WHERE OCCURS PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS S5.414 .2_______ PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS DESIGNED GRADE BEAM REINFORCEMENT SCHEDULED ADDITIONAL REINFORCEMENT WHERE OCCURS (HOOK BARS AT END OF GRADE BEAM) S5.414 .3_______ 2' - 6"REMAINDERSCHEDULED ADDITIONAL REINFORCEMENT WHERE OCCURS STUD / ANCHOR S5.414 .1_______ . S5.414 .5_______ ANCHORS LOCATED WITHIN ≤1.5 x EMBEDMENT LENGTH OF ANCHOR BOLT TO BE CONSIDERED CORNER BEAM DEPTH( 2' - 0" MIN)LAP SPLICE = 1.3ℓd5"EMBEDMENTSCHEDULED ADDITONAL REINFORCEMENT TYPICAL FACE OF STEM WALL FACE OF STEM WALL WHERE BRICK LEDGE OCCURS 5 1/2" 1 1/2" 8" DASHED LINE INDICATES INSULATION BEYOND (INTERUPTED AT GRADE BEAM) DESIGNED FOUNDATION STEM WALL REINFORCEMENT BEAM DEPTH( 2' - 0" MIN)COUPLER SCHEDULED ANCHOR ROD 5" CONT DESIGNED GRADE BEAM BOTT REINFORCEMENT TYPICAL FACE OF STEM WALL FACE OF STEM WALL WHERE BRICK LEDGE OCCURS 5 1/2" 1 1/2" 8" DASHED LINE INDICATES INSULATION BEYOND (INTERUPTED AT GRADE BEAM) DESIGNED FOUNDATION STEM WALL REINFORCEMENT TYPE 1 TYPE 2 CONT DESIGNED GRADE BEAM BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENT DOWELS TO MATCH CONT BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENT -DRILL AND SET W/ HILTI HY-200 V3 ADHESIVE SCHEDULED ANCHOR BOLT COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT BEAM DEPTH( 2' - 0" MIN)LAP SPLICE = 1.3ℓd5" SCHEDULED ADDITONAL REINFORCEMENT TYPICAL FACE OF STEM WALL FACE OF STEM WALL WHERE BRICK LEDGE OCCURS 5 1/2" 1 1/2" 8" DASHED LINE INDICATES INSULATION BEYOND (INTERUPTED AT GRADE BEAM) DESIGNED FOUNDATION STEM WALL REINFORCEMENT TYPE 3 CONT DESIGNED GRADE BEAM BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENT DOWELS TO MATCH CONT BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENT -DRILL AND SET W/ HILTI HY-200 V3 ADHESIVE COUPLER SCHEDULED ANCHOR ROD SCHEDULED SIMPSON ANCHOR BLOCK CONNECTIOR PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS 5/16" 1" CLR PL1X8X0'-8" INSTALLED DIRECTLY ABOVE GRADE BEAM BOTT REINFORCEMENT PROJPROJEMBEDMENTPROJS5.414 .2_______ S5.414 .2_______ S5.414 .2_______ 5 1/2"1 1/2" MIN 8" 2 3/4" TYPICAL FACE OF STEM WALL FACE OF STEM WALL WHERE BRICK LEDGE OCCURS DESIGNED FOUNDATION STEM WALL REINFORCEMENT 2 3/4" MINMIN 8" 5 1/2"2 1/2" 2 3/4" TYPICAL FACE OF STEM WALL FACE OF STEM WALL WHERE BRICK LEDGE OCCURS DESIGNED FOUNDATION STEM WALL REINFORCEMENT COUPLER SCHEDULED ANCHOR ROD TYPICAL FACE OF STEM WALL FACE OF STEM WALL WHERE BRICK LEDGE OCCURS SCHEDULED ADDITIONAL REINFORCEMENT TYPE 1 TYPE 2 TYPE 3 SCHEDULED ANCHOR BOLT COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT S5.414 .6_______ S5.414 .6_______ COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT SCHEDULED SIMPSON ANCHOR BLOCK CONNECTOR PL1X6X0'-8" 5/16"PROJPROJPROJ1'-6" @ ATR1-1/8 & ATR1-1/42' - 0" @ ATR1-3/8 & ATR1-1/24'-0" SQ @ ATR1-1/8 & ATR1-1/4 5' - 0" SQ @ ATR1-1/8 & ATR1-1/4 5 1/2" 1' - 8"1' - 8"1 1/2" CLR 6" (3) SETS OF PILASTER TIES AT 3" O.C. @ TOP OF PILASTER #5 @ 10" O.C. EA. WAY (TOP & BOTT)2 1/2"2 1/2"1' - 0"(7)#5 VERT W/ (2) #3 CLOSED TIES AT 8" O.C. MAX.EQUALEQUALDESIGNED FOUNDATION STEM WALL REINFORCEMENT A Detail A EQUALEQUAL4"4"SCHEDULED ADDITIONAL REINFORCEMENT ROD TO BE ANGLED OVER PER SIMPSON'S GUIDELINES TO BE CENTER IN WALL AT LEVEL ABOVE 3 1/4"BEAM DEPTH( 2' - 0" MIN)CONT DESIGNED GRADE BEAM BOTT REINFORCEMENTTYPE 1 HOOK CONTINUOUS REINFORCEMENT AT FAR SIDE OF GRADE BEAM BEAM DEPTH( 2' - 0" MIN)COUPLER SCHEDULED ANCHOR ROD PROJEMBEDMENTSCHEDULED ADDITONAL REINFORCEMENT CONT BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENTTYPE 23"EQ EQ HOOK CONTINUOUS ADDITIONAL REINFORCEMENT AT FAR SIDE OF GRADE BEAM SCHEDULED ANCHOR BOLT DESIGNED GRADE BEAM REINFORCEMENT DESIGNED GRADE BEAM REINFORCEMENT BEAM DEPTH( 2' - 0" MIN)COUPLER SCHEDULED ANCHOR ROD SCHEDULED ADDITONAL REINFORCEMENT CONT BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENTTYPE 33" EQ EQ HOOK CONTINUOUS ADDITIONAL REINFORCEMENT AT FAR SIDE OF GRADE BEAM PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS DESIGNED GRADE BEAM REINFORCEMENT SCHEDULED SIMPSON ANCHOR BLOCK CONNECTIOR PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT 5/16" PL1X8X0'-8" INSTALLED DIRECTLY ABOVE GRADE BEAM BOTT REINFORCEMENT PROJEMBEDMENTPROJS5.414 .2_______ S5.414 .2_______ S5.414 .2_______ XX ANCHOR BOLT ORIENTATION FOR SB AND SSTB ANCHOR BOLTS (INSTALL W/ ARROW ON HEAD STAMP ORIENTED AS SHOWN SSTB & SB ANCHOR BOLT CORNER 45° MID-WALL ANCHOR BOLT ORIENTATION FOR SB AND SSTB ANCHOR BOLTS (INSTALL W/ ARROW ON HEAD STAMP ORIENTED AS SHOWN 45°4 5 °XXSSTB & SB ANCHOR BOLT ANCHOR BOLT ORIENTATION FOR SB AND SSTB ANCHOR BOLTS (INSTALL W/ ARROW ON HEAD STAMP ORIENTED AS SHOWN 4 5 °END-WALL / STEP IN WALLXXSSTB & SB ANCHOR BOLT 45°45°MIN 5"END OF WALL / STEP IN WALL S5.414 .7_______ COUPLER SCHEDULED ANCHOR ROD BEAM WIDTH SCHEDULED ANCHOR BOLT EMBEDMENTBEAM DEPTH( 2' - 0" MIN)NOTE: 1. ANCHOR BOLT EMBEDMENT TO BE MEASURED FROM LOWER SLAB AT DROP 2. FOR GRADE BEAM REINFORCEMENT AT ANCHOR SEE SCHEDULE / DETAIL SEE PLANSTEP/2 S5.414 STEP AT INTERIOR ANCHOR LOCATION (GRADE BEAM) COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT PAB ANCHOR BOLTEMBEDMENT ATNOTE: 1. ANCHOR BOLT EMBEDMENT TO BE MEASURED FROM LOWER SLAB AT DROP FOR PAB ANCHOR BOLTS 2. FOR STEM WALL REINFORCEMENT AT ANCHOR SEE SCHEDULE / DETAIL SEE PLANSTEPSTEP IN WALL AT EDGE ANCHOR LOCATION (STEM WALL) MIN 5" 2 3/4" MIN /1 S5.414PROJ PROJCOUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT 5" MIN PROVIDE (2) #3 U-BARS AROUND ANCHOR BOLT 2'-6" END OF WALL AT EDGE ANCHOR LOCATION (STEM WALL) NOTE: STEPS OVER 12" CONSIDERED END OF WALL BEAM DEPTH( 2' - 0" MIN)CONT DESIGNED GRADE BEAM BOTT REINFORCEMENTTYPE 1 HOOK CONTINUOUS REINFORCEMENT AT FAR SIDE OF GRADE BEAM BEAM DEPTH( 2' - 0" MIN)COUPLER SCHEDULED ANCHOR ROD PROJEMBEDMENTSCHEDULED ADDITONAL REINFORCEMENT CONT BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENTTYPE 23"EQ EQ HOOK CONTINUOUS ADDITIONAL REINFORCEMENT AT END OF GRADE BEAM SCHEDULED ANCHOR BOLTPROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS PAST ANCHOR EXTEND GRADE BEAM 2' - 0" (MIN) COUPLER SCHEDULED ANCHOR ROD SCHEDULED ANCHOR BOLT BEAM DEPTH( 2' - 0" MIN)COUPLER SCHEDULED ANCHOR ROD SCHEDULED ADDITONAL REINFORCEMENT CONT BEAM BOTT REINFORCEMENT / SCHEDULED ADDITONAL REINFORCEMENTTYPE 33"EQ EQ HOOK CONTINUOUS ADDITIONAL REINFORCEMENT AT END OF GRADE BEAM PROVIDE TIE EACH SIDE OF ANCHOR WHERE SCHEDULED ADDITIONAL REINFORCEMENT OCCURS PAST ANCHOR EXTEND GRADE BEAM 2' - 0" (MIN) SCHEDULED SIMPSON ANCHOR BLOCK CONNECTIOR 5/16" PL1X8X0'-8" INSTALLED DIRECTLY ABOVE GRADE BEAM BOTT REINFORCEMENT PROJEMBEDMENTPROJS5.414 .2_______ S5.414 .2_______ S5.414 .2_______ Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:44 PMS5.414 Wood Shear Wall Anchorage ATR / Rod System - Strip and Stem Fdns Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 3/4" = 1'-0"2 Anchor Rod Anchorage - Interior 3/4" = 1'-0"4 Anchor Rod Anchorage - Near Edge 3/4" = 1'-0"1 Anchor Rod Anchorage - Slab Edge / Corner 3/4" = 1'-0"3 Anchor Rod Anchorage - Interior at Grade Beam Intersection 1" = 1'-0"6 Anchor Orientation 3/4" = 1'-0"7 Anchor Bolt at Step / End of Stem Wall 3/4" = 1'-0"5 Anchor Rod Anchorage - Interior at End of Grade Beam No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 TIE-DOWN EACH BEARING POINT 7, 8, 9 GIRDER TRUSS (GT) UPLIFT TIE-DOWN SCHEDULE1 AT FLAT ROOF TIE-DOWN ROD SIZE 3 NUMBER OF TRUSS PLIES G.T. UPLIFT REACTION 10 LGT2 -#9 LGT3-SDS2.5 / LGT4-SDS3 HTT5 @ GT & STUD PACK / POST (2) HTT5 @ GT & STUD PACK / POST ATR3/84 ATR1/25 ATR5/8 (2) ATR5/8 2 3 OR 4 2 OR MORE 3 OR MORE 701 -2,124 LBS 2,124 -2,505 LBS 2,506 -4,375 LBS 4,376 -8,680 LBS GT UPLIFT TIE-DOWN SCHEDULE NOTES: 1. UPLIFT RESTRAINT IS PROVIDED BY SIMPSON STRONG-TIE "URS" SYSTEM AND SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS (TYPICAL). ROOF ANCHOR TYPES ARE MANUFACTURED BY SIMPSON STRONG-TIE AND SHALL BE INSTALLED PER MANUFACTURER REQUIREMENTS, TYP. 2. TIE-DOWN RODS, TAKE-UP SHRINKAGE COMPENSATING DEVICES AND BEARING PLATE MODELS BY SIMPSON STRONG-TIE AS NOTED. 3. ATR RODS SHALL BE CAST IN PLACE INTO FOUNDATION OR PODIUM WITH 7" MINIMUM EMBEDMENT WITH HEAVY HEX NUTS FITTED AT EMBEDDED END AND TACK WELDED TO ROD. A MINIMUM 2 3/4" CONCRETE EDGE DISTANCE FROM CENTER OF ROD. CORNER CONDITIONS ARE NOT PERMITTED WITH EDGE DISTANCES SHOWN. (AT CONTRACTORS OPTION, AT NON-PT LOCATIONS ATR RODS MAY BE DRILL AND EPOXY THREADED RODS IN HILTI HY-200 V3 ADHESIVE INSTALLED PER MANUFACTURER REQUIREMENTS.) 4. FOR BUILDINGS WITH WOOD FRAMING MORE THAN 3 STORIES IN HEIGHT, ATR3/8 TIE-DOWN RODS NEED ONLY EXTEND DOWN 3 LEVELS BELOW ROOF LEVEL WITH SCHEDULED SIMPSON WBP AND NUT BELOW DOUBLE TOP PLATE. SEE DETAIL 5. FOR BUILDINGS WITH WOOD FRAMING MORE THAN 4 STORIES IN HEIGHT, ATR1/2 TIE-DOWN RODS NEED ONLY EXTEND DOWN 4 LEVELS BELOW ROOF LEVEL WITH SCHEDULED SIMPSON WBP AND NUT BELOW DOUBLE TOP PLATE. SEE DETAIL 6. DO NOT PROVIDE FIRE CAULKING IN 2X PLATES AT TAKE-UP SHRINKAGE COMPENSATING DEVICES (TYPICAL). 7. LGT2 AND LGT3 TIE-DOWNS TO BE INSTALLED WITH #9 SD / SDS SCREWS PER MANUFACTURER. HTT5 TIES TO BE INSTALLED WITH 0.148"⌀x 3" LONG NAILS OR 0.162"⌀x 2 1/2" NAILS, U.N.O. 8. WHERE LGT TIE-DOWN OCCURS OVER HEADER OR FLUSH BEAM, SEE DETAIL 9. WHERE HTT5 OCCURS OVER HEADER OR FLUSH BEAM, SEE DETAIL 10. G.T. UPLIFT REACTIONS ARE INDICATED ON TRUSS DESIGN DRAWINGS PROVIDED BY THE WOOD TRUSS MANUFACTURER IN ACCORDANCE WITH THE WOOD GENERAL NOTES. GTGT TIE-DOWN -SEE SCHEDULE TIE DOWN ROD -SEE SCHEDULE 6" MAX TIE-DOWN ROD COUPLER TO MATCH TENSILE CAPACITY OF SCHEDULED TIE- DOWN ROD (TYP) GT TIE-DOWN -SEE SCHEDULE DOUBLE TOP PLATE STUD PACK / SOLID POST -SEE PLAN / GENERAL NOTES (TYP) -(4) 2X STUDS MINIMUM TIE DOWN ROD -SEE SCHEDULE STUD PACK / SOLID POST -SEE PLAN / GENERAL NOTES (TYP) -(4) 2X STUDS MINIMUM GT TIE-DOWN -SEE SCHEDULE TIE DOWN ROD -SEE SCHEDULE RTUD TAKE UP DEVICE AND BEARING PLATE - SEE SCHEDULE (TYP) TIE-DOWN ROD COUPLER TO MATCH TENSILE CAPACITY OF SCHEDULED TIE- DOWN ROD (TYP) DOUBLE TOP PLATE FLOOR CAVITY VARIES -SEE FLOOR DETAILS (TYP) STUD PACK / SOLID POST -SEE PLAN / GENERAL NOTES (TYP) -(4) 2X STUDS MINIMUM SINGLE BOTTOM PLATE (TYP) DOUBLE TOP PLATE (TYP) (2) HTT5 Condition HTT5 Condition LGT Condition GT TIE-DOWN -SEE SCHEDULE 6" MAX 6" MAX RTUD TAKE UP DEVICE AND BEARING PLATE - SEE SCHEDULE GT TIE-DOWN -SEE SCHEDULE 6" MAX TAKE-UP DEVICE 6 RTUD3B RTUD4B RTUD5 (2) RTUD5 BEARING PLATE BPRTUD3-4B BPRTUD3-4B BPRTUD5-6B (2) BPRTUD5-6B S5.420 3 . 1 OR MORE0-700 LBS H2.5A ---...FLOOR CAVITY VARIES -SEE FLOOR DETAILS (TYP) SINGLE BOTTOM PLATE (TYP) DOUBLE TOP PLATE (TYP) GT GTRTUD TAKE UP DEVICE AND BEARING PLATE - SEE SCHEDULE TIE-DOWN ROD COUPLER TO MATCH TENSILE CAPACITY OF SCHEDULED TIE- DOWN ROD (TYP) FLOOR CAVITY VARIES -SEE FLOOR DETAILS (TYP) SINGLE BOTTOM PLATE (TYP) DOUBLE TOP PLATE (TYP) DOUBLE TOP PLATE /6 S5.420 /6 S5.420 DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE S5.420 .2_______ S5.420 .2_______ /4 S5.420 /5 S5.420 PROVIDE ADDITIONAL 2X6 VERT W/ (16) SDWS22300 SCREWS INTO SOLID TRUSS MEMBERS DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE HTT5 AT FLAT ROOF CONDITION PROVIDE 5/8" DIA THREADED ROD PER MANUF SIMPSON HTT5 SIMPSON HTT5 DOUBLE TOP PLATE TIE-DOWN ROD COUPLER TO MATCH TENSILE CAPACITY OF SCHEDULED TIE- DOWN ROD (TYP) STUD PACK / SOLID POST OR TRIMMER / KINGPOST SCHEDULED ROD COMPONENT TIE DOWN ROD -SEE SCHEDULE SINGLE BOTTOM PLATE (TYP) FLOOR CAVITY VARIES -SEE FLOOR DETAILS (TYP) 6".DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE SCHEDULED ROD COMPONENT ATR3/8 1/4"x3"x3" PLATE WASHER W/ 3/8" DOUBLE HEAVY HEX NUT** TIE-DOWN ROD SIZE SIMPSON WBP4-3x3.5 W/ 1/2 HEAVY HEX NUTATR1/2 COMPONENT ** ALTERNATIVELY, COMPONENTS MAY BE INSTALLED AT TOP OF ROD WITH RTUD ASSEMBLY PROVIDED AT BOTTOM OF ROD GT TIE-DOWN -SEE SCHEDULE DOUBLE TOP PLATE STUD PACK / SOLID POST GT TIE-DOWN -SEE SCHEDULE GT MAX 4" KINGPOST (TYP) TRIMMER STUDS OR SOLID POST -SEE PLAN / GENERAL NOTES (TYP) TYPICAL ROOF TRUSS UPLIFT HARDWARE FOR SINGLE HTT5 TIE DOWN FASTEN HEADER / FLUSH BEAM TO STUDS BELOW W/ (3) CS16 STRAPS (ONE SIDE OF WALL ONLY). FOR DOUBLE HTT5 TIE-DOWN FASTEN HEADER/FLUSH BEAM TO STUDS BELOW W/ (3) CS16 STRAPS WRAPPED AROUND HEADER / BEAM AND FASTENED TO STUDS ON EA. SIDE OF WALL. HEADER -SEE PLAN SIMPSON WBP6-3X5.5 BEARING PLATE AND NUT. CRIMP TREADS AND COUNTERSINK (1" MAX) WHERE REQUIRED. DOUBLE TOP PLATE ROOF TRUSS TAKE UP DEVICE AND BEARING PLATE -SEE SCHEDULE DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE FLUSH BEAM GIRDER TRUSS GIRDER TRUSS TIE-DOWN -SEE SCHEDULE WHEN REQ'D1" MAX RECESSDOUBLE TOP PLATE ROOF TRUSS FLUSH BEAM MAX 4" KINGPOST (TYP) TRIMMER STUDS OR SOLID POST -SEE PLAN / GENERAL NOTES (TYP) TYPICAL ROOF TRUSS UPLIFT HARDWARE TAKE UP DEVICE AND BEARING PLATE -SEE SCHEDULE FASTEN HEADER/FLUSH BEAM TO STUDS BELOW W/ (2) CS16 STRAPS. (ONE SIDE OF WALL ONLY) DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE HEADER -SEE PLAN GIRDER TRUSS SIMPSON WBP6-3X5.5 BEARING PLATE AND NUT GIRDER TRUSS TIE- DOWN -SEE SCHEDULE Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:49 PMS5.420 Roof Girder Truss Uplift Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/2" = 1'-0"1 Girder Truss Uplift Detail - Flat Roof 1 1/2" = 1'-0"3 Girder Truss Uplift Detail - Double Tie-Down 1" = 1'-0"6 Roof Tie-Down Rod Termination at Plate 1" = 1'-0"2 Girder Truss Uplift Detail - Flat Roof 1" = 1'-0"5 HTT5 Tie-Down Over Header / Flush Beam 1" = 1'-0"4 LGT Tie-Down Over Header / Flush Beam No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 ROOF CLIPS AT HEADER 3 ROOF BEAM / DEEP HEADER UPLIFT TIE-DOWN SCHEDULE TIE-DOWN ROD SIZE 4 4'-0" < R.O. < 7'-11" EMBEDMENT INTO CONCRETE 5, 7 MIN EDGE DISTANCE 6 8'-0" < R.O. < 12'-0" (2) CS16 STRAPS (3) CS16 STRAPS ATR3/8 ATR1/2 - 6" MIN.2 3/4" - ROOF HEADER UPLIFT TIE-DOWN SCHEDULE NOTES: 1. UPLIFT RESTRAINT IS PROVIDED BY SIMPSON STRONG-TIE "URS" SYSTEM AND SHALL BE INSTALLED PER MANUFACTURER REQUIREMENTS (TYPICAL). 2. R.O. OPENING WIDTH IS MEASURED AS CLEAR SPAN / ROUGHT OPENING WIDTH (TYPICAL). 3. ROOF HEADER CLIPS ARE MANUFACTURED BY SIMPSON STRONG-TIE AND SHALL BE INSTALLED PER MANUFACTURER REQUIREMENTS. FOR DFL LUMBER, SPACING MAY BE INCREASED TO 22" OC MAX. 4. TIE-DOWN RODS AND TAKE UP SHRINKAGE COMPENSATING DEVICES TO BE SIMPSON STRONG ROD MODEL AS NOTED. DO NOT PROVIDE FIRE CAULKING IN 2X PLATES AT TAKE UP SHRINKAGE COMPENSATING DEVICES. 5. ANCHORAGE TO CONCRETE SHALL BE CAST IN PLACE INTO FOUNDATION OR PODIUM WITH 7" MINIMUM EMBEDMENT WITH HEAVY HEX NUTS FITTED AT EMBEDDED END AND TACK WELDED TO ROD. A MINIMUM 2 3/4" CONCRETE EDGE DISTANCE FROM CENTER OF ROD. CORNER CONDITIONS ARE NOT PERMITTED WITH EDGE DISTANCES SHOWN. (AT CONTRACTORS OPTION, AT NON-PT LOCATIONS ATR RODS MAY BE DRILL AND EPOXY THREADED RODS IN HILTI HY-200 V3 ADHESIVE INSTALLED PER MANUFACTURER REQUIREMENTS.) 6. MIN EDGE DISTANCE SHALL BE MEASURED FROM CENTER OF ROD ANCHOR TO NEAREST CONCRETE EDGE (TYPICAL). 7. FOR BUILDINGS WITH WOOD FRAMING MORE THAN 4 STORIES IN HEIGHT; OPENINGS LESS THAN 8'-0" IN WIDTH, ATR TIE-DOWN RODS NEED ONLY EXTEND DOWN 3 LEVELS BELOW ROOF LEVEL WITH SCHEDULED SIMPSON WBP AND NUT BELOW DOUBLE TOP PLATE. 8. STRAPPING MAY BE PROVIDED ON EITHER SIDE OF WALL BUT IS ONLY REQUIRED TO BE PROVIDED ON ONE SIDE OF WALL. TAKE UP DEVICE - SEE SCHEDULE TIE DOWN ROD -SEE SCHEDULE DOUBLE TOP PLATE FLOOR CAVITY VARIES -SEE FLOOR DETAILS (TYP) KINGPOST (TYP) SINGLE BOTTOM PLATE (TYP) DOUBLE TOP PLATE (TYP) ROOF TRUSS 4" TRIMMER STUDS OR SOLID POST -SEE PLAN / GENERAL NOTES (TYP) TAKE-UP DEVICE 4 RTUD3B RTUD4B ROOF STRAPS AT FLUSH BEAM ENDS 8 SILL PLATE AT WINDOW S5.421 3 . S5.421 2 . HEADER FLUSH BEAM TIE-DOWN ROD COUPLER TO MATCH TENSILE CAPACITY OF SCHEDULED TIE- DOWN ROD (TYP).DSP @ 16" O.C. DSP @ 16" O.C. BEARING PLATE BPRTUD3-4B BPRTUD3-4B DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE ROUGH OPENING WIDTH 2 (R.O.) R.O. < 3'-11"(1) CS16 STRAPDSP @ 16" O.C. DOUBLE TOP PLATE ROOF TRUSS HEADER TAKE UP DEVICE AND BEARING PLATE -SEE SCHEDULE ROOF CLIPS AT HEADER -SEE SCHEDULE 4" KINGPOST (TYP) TRIMMER STUDS OR SOLID POST -SEE PLAN / GENERAL NOTES (TYP) UPLIFT HARDWARE PER ROOF TRUSS UPLIFT SHEET INFILL FRAMING AS REQUIRED DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE FLUSH BEAM 4" KINGPOST (TYP) TRIMMER STUDS OR SOLID POST -SEE PLAN / GENERAL NOTES (TYP) UPLIFT HARDWARE PER ROOF TRUSS UPLIFT SHEET TAKE UP DEVICE AND BEARING PLATE -SEE SCHEDULE STRAP EACH END - SEE SCHEDULE DOUBLE TOP PLATE ROOF TRUSS DRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE ROOF TRUSS BEARING DOUBLE TOP PLATE SCHEDULED WALL STUDS ROOF TRUSS SCHEDULED TOP LEVEL DOUBLE TOP PLATE TO STUD SCREWS 2 SCHEDULED ROOF TRUSS BEARING POINT CLIPS 2 TRUSS BLOCK SCREW SPACING SCHEDULED STUD TO DBL TOP PLATE CLIP SPACING SCHEDULED STUD TO DBL TOP PLATE SHRINKAGE COMPENSATING TAKE-UP DEVICE PER MANUFACTURER SCHEDULED TOP LEVEL DOUBLE TOP PLATE TO STUD SCREWS 2 SCHEDULED ROOF TRUSS BEARING POINT SCREWS 2 NOTES: 1. SEE PROVIDED DETAIL FOR MORE INFORMATION. 2. CLIPS TO DOUBLE TOP PLATES SHALL BE SIMPSON H2.5A OR APPROVED EQUAL. CLIPS TO SINGLE BOTTOM PLATE TO BE SIMPSON H3 CLIP OR APPROVED EQUAL. ALTERNATE SCREW ATTACHMENT TO BE SIMPSON SDWC15600 OR APPROVED EQUAL INSTALLED PER MANUF REQUIREMENTS. 3. CONTINUOUS ROD IS TO BE 3/8" DIA SIMPSON UPLIFT RESTRAINT PROVIDED BY SIMPSON STRONG-TIE "URS" SYSTEM AND SHALL BE INSTALLED PER MANUF REQUIREMENTS. ROD SYSTEM SHALL EXTEND FROM UPPER MOST TOP PLATE DOWN THROUGH 2 FLOOR CAVITIES MINIMUM. ONE AND TWO LEVEL BUILDINGS SHALL HAVE ROD SYSTEM CAST INTO FOUNDATION OR PODIUM W/ 7" EMBEDMENT W/ HEAVY HEX NUTS FITTED TO END AND TACK WELDED IN PLACE. (AT CONTRACTORS OPTION, AT NON-PT LOCATIONS ATR RODS MAY BE DRILL AND EPOXY THREADED RODS IN HILTI HY-200 V3 ADHESIVE INSTALLED PER MANUFACTURER REQUIREMENTS.) 4. OVERALL ROOF TRUSS TRIB LENGTH IS DEFINED HEREIN: FLOOR TRUSS FLOOR TRUSS BEARING TRUSS BLOCKS SCHEDULED WALL STUDS SCHEDULED WALL STUDS FOUNDATION / PODIUM SCHEDULED ACHOR BOLTS DOUBLE TOP PLATE SCHEDULED WALL STUDS KNEE WALL / DRAG FLOOR TRUSS OVER WALL FLOOR TRUSS PARALLEL BOTTOM PLATE SCHEDULED WALL STUDS BOTTOM PLATE DOUBLE TOP PLATE SCHEDULED WALL STUDS BOTTOM PLATE SCHEDULED URS SPACING SCHEDULED URS SPACING CLEAR 6" MIN EMBEDMENTDRILL THROUGH PLATES AT EACH LEVEL AS APPLICABLE (SEE FOUNDATION NOTES) SCHEDULED ANCHOR BOLT SPACING (SEE FOUNDATION NOTES) SCHEDULED ANCHOR BOLT SPACING URS ROD AT LOCATIONS THAT EXTEND TO CONCRETE 4 BEARING PLATE AND NUT PER MANUFACTURER SIMPSON URS SYSTEM (TYPICAL) LEXT OVERALL ROOF TRUSS BEARING TRIB 4 DOUBLE TOP PLATE TO STUD CONNECTION W/ CLIPS OR SCREWS 2 10'-1" TO 18'-0" (1) @ 16" O.C. 4'-0" TO 10'-0" - 3'-11" OR LESS TOP LEVEL TOP 2 LEVELS 3 ROOF TRUSS BEARING POINTS (1) @ EA. TRUSS(1) @ EA. TRUSS (1) @ 48" O.C. - (1) @ 16" O.C. ROOF TRUSS UPLIFT AT EXTERIOR BEARING WALL SCHEDULE 1 DOUBLE TOP PLATE TO ROOF TRUSS CONNECTION W/ CLIPS OR SCREWS 2 (1) @ EA. TRUSS CONTINUOUS ROD -(1) @ 48" O.C. LEXT OVERALL ROOF TRUSS BEARING TRIB 4 DOUBLE TOP PLATE TO STUD CONNECTION W/ CLIPS OR SCREWS 2 10'-1" TO 18'-0" (1) @ 16" O.C. 4'-0" TO 10'-0" - 3'-11" OR LESS TOP LEVEL TOP 2 LEVELS 3 ROOF TRUSS BEARING POINTS (1) @ EA. TRUSS(1) @ EA. TRUSS (1) @ 48" O.C. - ROOF TRUSS UPLIFT AT INTERIOR BEARING WALL SCHEDULE 1 DOUBLE TOP PLATE TO ROOF TRUSS CONNECTION W/ CLIPS OR SCREWS 2 - CONTINUOUS ROD -- EXTERIOR ROOF BEARING WALL EXTERIOR ROOF BEARING WALL 2' - 10 3/4"4' - 3"3' - 8 3/8" EQ EQ EQ EQ LEXT LINT LINT INTERIOR OVERALL ROOF TRIB EXT OVERALL ROOF TRIB INTERIOR OVERALL ROOF TRIB GIRDER TRUSSINTERIOR ROOF BEARING WALL EQ EQ JACK TRUSS 6" LEXT EXT OVERALL ROOF TRIB EQ EQ Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:19:54 PMS5.421 Roof Truss Uplift Details Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/2" = 1'-0"1 Roof Header Uplift Tie-Down 1" = 1'-0"2 Roof Deep Header Tie-Down Enlarged Detail 1" = 1'-0"3 Roof Flush Beam Tie-Down Enlarged Detail 1" = 1'-0"4 Uplift at Floor Trusses No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 1" SLOPE 1/4"/FT PROVIDE 2" RECESS FOR DOOR THRESHOLD, RE: ARCH FOR EXACT LOCATION (TYP. @ HATCHED AREAS) 29' - 6"26' - 0"38' - 5 1/2"7' - 6 1/2"0"27' - 9 1/2"13' - 3"26' - 9 1/2"21' - 10"69' - 4"12' - 0"8' - 4"29' - 6"26' - 0"46' - 0" 101' - 6" 6X6 POST W/ ABU66Z BASE (TYPICAL 6 LOCATIONS) PROVIDE RECESS FOR SPECIALTY DOOR THRESHOLD -RE: ARCH F-3 TOF =-3' - 0" F-3 TOF =-3' - 0" F-3 TOF =-3' - 0" F-3 TOF =-3' - 0" FINISH MATERIAL -RE: CIVIL/LANDSCAPE • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS LEASING / AMENITY S3.100 .5_______ (TYP. @ INTERIOR GRADE BEAMS U.N.O.) S3.100 .1_______ S3.100 .1_______ S3.100 .1_______ S3.100 .1_______ S3.100 .1_______89' - 8"89' - 8"101' - 6" B/FTG @ CLUBHOUSE = 48'-0" (U.N.O.) S3.101 2_______ S3.101 1_______ 1 (VERIFY W/ ARCH) 2' - 0 1/2"13' - 7" (VERFY W/ ARCH)CONTINUOUS FOOTING SEE DET. /2 S3.101 (2) #5 X 5'-0" AT RE-ENTRANT CORNERS, TYP. RE: ARCH Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:10:27 PMSC1.101 Foundation Plan - Clubhouse Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Foundation Plan - Level 1 FDN-Spread Footing Schedule Type Length Width Thickness Reinforcement F-3 3' - 0" 3' - 0" 1' - 0" (3) #5 EA. WAY FDN-Wall Footing Schedule Type Width Foundation Thickness Reinforcement WF-24 2' - 0" 1' - 0" FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 1 RFI 015 03/05/26 100% IFC 03/18/26 S4.310 .1_______ S4.310 .2_______ S4.310 .2_______ S4.310 .1_______ S4.310 .2_______ S4.310 .2_______ S4.310 .1_______ 2-2x8 2-2x8 2-2x82-2x82-2x83-2x12 3-2x8 3-2x10 3-2x12 2-2x83-2x123-2x12.1GL5-9GL5-92-2x82-2x82-2x82-2x82-2x82-2x83-2x12.12-2x82-2x82-2x82-2x8 2-2x8 2-2x8 2-2x8 2-2x8 3-2x12.13-2x12.12-2x83-2x83-2x12.12-2x8 3-2x83-2x10 3-2x8 3-2x8 3-2x83-2x82-2x8 2-2x82-2x82-2x8HEAVY TIMBER TRUSS (SEE DET. ) GL5-15 GL5-15 (3)2x6 KINGSTUDS & (2)2x6 TRIMMERS (3)2x6 KINGSTUDS & (2)2x6 TRIMMERS EACH SIDE OF OPENING GT 3-2x12S4.310 .2_______ S4.310 .4_______ HATCHED AREA INDICATES VAULTED CEILING, RE: ARCH & INTERIORS FOR EXTENTS 6X6 POST W/ ABU66Z BASE (TYPICAL 6 LOCATIONS) CONT. (2)2X6 STUDPACK SEE 5/S0.300 AT DEEP HEADERS, TYP. REFERENCE DETAIL FOR GLU LAM BEAM CONNECTION AT EXTERIOR WALL REFERENCE DETAIL FOR GLU LAM BEAM CONNECTION AT EXTERIOR WALL AT STRING LIGHT ANCHOR POINTS, PROVIDE DOUBLE 2x8 BLOCKING BETWEEN STUDS FASTENED W/ (3) SDWC15600 SCREWS EACH END, RE: LANDSCAPE / ARCH ATTIC ACCESS OPENING, RE: ARCH FOR EXACT LOCATION AND SIZE, TYP S4.310 .6_______ (2)2x6 KINGSTUDS & (3)2x6 TRIMMERS HEAVY TIMBER TRUSS (SEE DET. ) HEAVY TIMBER TRUSS (SEE DET. ) HEAVY TIMBER TRUSS (SEE DET. ) HEAVY TIMBER TRUSS (SEE DET. )/2 S4.313 /2 S4.313 /2 S4.313 /2 S4.313 /2 S4.313 /3 S4.313 /3 S4.313 S4.313 .1_______ S4.312 .1_______ S4.314 .1_______ S4.314 .2_______ S4.314 .3_______ 0". GT GT SC2.102 2 . DIAGONAL HATCHING INDICATES EXTENTS OF MECHANICAL ROOM TRUSS MFG TO PROVIDE DOOR OPENING IN GT - RE: ARCH. PROVIDE 2x8 COLLAR TIES @ EVERY OTHER RAFTER 2x10 RIDGE BOARD2x8 RAFTERS @ 24" O.C.GREY AREAS IDICATE 2x8 OVERFRAMING TO MATCH ROOF PROFILE DIAGONAL HATCHED AREA INDICATES ATTIC FLOOR SHEATHING/PLATFORM 5' - 0" 2x6 PLATFORM JOISTS @ 24" O.C. GT GTGT19' - 1 0 3 / 4 " 2x6 PLATFORM JOISTS @ 24" O.C. ADDITIONAL (3)2x3 TRIMMERS AS REQUIRED AT STOREFRONT -RE: ARCH. ADDITIONAL (3)2x3 TRIMMERS AS REQUIRED AT STOREFRONT -RE: ARCH. 1 WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 3. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 4. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 5. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 6. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 7. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 8. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 9. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 10. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 11. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 12. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 350 PLF DRAG FORCE (TYPICAL). 13. ROOF UPLIFT MAY EITHER BE PROVIDED WITH CONTINUOUS ROD SYSTEM. LEGEND: = LOAD BEARING / EXTERIOR NON-LOAD BEARING WOOD FRAMED STUD WALL BELOW = HEADER (DROP BEAM) = FLUSH BEAM = LEDGER = TRUSS / JOIST = GIRDER TRUSS WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK DOUBLE 2x10 FLOOR JOISTS @ 24" O.C. DOUBLE 2x10 FLOOR JOISTS @ 24" O.C. ATTIC ACCESS OPENING, RE: ARCH FOR EXACT LOCATION AND SIZE, TYP 2-2x8 2-2x8 3-2x103-2x10HUC 210-2 HANGERS Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:10:29 PMSC2.102 Framing Plan - Roof - Clubhouse Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Framing Plan - Roof Wood Beam Schedule Mark Beam / Header 2-2x8 (2) 2x8 3-2x8 (3) 2x8 3-2x10 (3) 2x10 3-2x12 (3) 2x12 3-2x12.1 (3) 2x12 No. 1 Grade GL5-9 5 1/8 x 9 GLU LAM GL5-15 5 1/8 x 15 GLU LAM P5-14 5 1/2 x 14 PSL 1/4" = 1'-0"2 Mechanical Room Floor Framing Plan NOTE: TRUSSES TO BE SPACED AS NEEDED TO AVOID RECESSED LIGHTING AND MECH. EQUIPMENT AS INDICATED ON MEP DOCUMENTS, TYPICAL. RE: ARCH & INTERIORS FRO CEILING VAULTS, TRAY CEILINGS, ETC. No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 1 RFI 015 03/05/26 100% IFC 03/18/26 WSW-1 WSW-1WSW-1WSW-1WSW-1WSW-1WSW-1WSW-1 WSW-1WSW-1 WSW-1 WSW-1S3.101 2_______ S3.101 1_______ WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. PROVIDE TRUSS BLOCKS ABOVE ALL SHEAR WALLS SUPPORTING OR BELOW BOTTOM CHORD BEARING TRUSSES (ROOF AND FLOOR) 7. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 8. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 9. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM. SEE S5.410 THROUGH S5.515 SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:10:29 PMSC2.201 Wood Shearwall Plan - Clubhouse Hanover Company Hyannis Phase II Checker Author 10/01/58 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Shearwall Plan No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 68' - 4"20' - 0"S3.100 .2_______ S3.100 .2_______ S3.100 .3_______ SIM S3.100 .2_______SLOPE3 1/2"S3.100 .7_______ B/FTG @ GARAGE H = 47'-10" (U.N.O.) B/FTG @ GARAGE A = 46'-0" (U.N.O.) S3.100 .7_______20' - 0"A&H Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:00 PMSG1.101 Foundation Plan - Garage A & H Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS GARAGES 1/4" = 1'-0"1 Foundation Plan - Garage A & H No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 90' - 4" S3.100 .2_______SIM S3.100 .3_______ S3.100 .2_______ S3.100 .2_______3 1/2"SLOPES3.100 .7_______ B/FTG @ GARAGE G = 47'-8" (U.N.O.) B/FTG @ GARAGE B = 45'-6" (U.N.O.) S3.100 .7_______ B&G Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:01 PMSG1.102 Foundation Plan - Garage B & G Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS GARAGES 1/4" = 1'-0"1 Foundation Plan - Garage B & G No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 68' - 4"20' - 0"S3.100 .2_______SIM S3.100 .3_______ S3.100 .2_______ S3.100 .2_______3 1/2"SLOPES3.100 .7_______ B/FTG @ GARAGE C = 46'-4" (U.N.O.) B/FTG @ GARAGE F = 45'-9" (U.N.O.) C&F Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:07 PMSG1.103 Foundation Plan - Garage C & F Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS GARAGES 1/4" = 1'-0"1 Foundation Plan - Garage C & F No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 96' - 3"20' - 0"S3.100 .2_______SIM S3.100 .3_______ S3.100 .2_______ S3.100 .2_______3 1/2"SLOPES3.100 .7_______ B/FTG @ GARAGE D = 46'-0" (U.N.O.) D Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:09 PMSG1.104 Foundation Plan - Garage D / Maintenance Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS GARAGES 1/4" = 1'-0"1 Foundation Plan - Garage D / Maintenance No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 79' - 8"20' - 0"S3.100 .2_______SIM S3.100 .3_______ S3.100 .2_______ S3.100 .2_______3 1/2"SLOPES3.100 .7_______ E Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:13 PMSG1.105 Foundation Plan - Garage E / Dogwash Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 FOUNDATION NOTES: 1.CONTRACTOR TO CROSS REFERENCE AND/OR VERIFY ALL DIMENSIONS, ELEVATIONS, RECESSES, DEPRESSIONS, CURB SIZES/LOCATIONS, WALL ELEVATIONS, GUARDRAILS, FINISHES, OPENINGS AND SLAB PENETRATION SIZES/LOCATIONS WITH ARCHITECTURAL DRAWINGS AND NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.REFER TO ATCHITECTURAL SLAB DIMENSIONAL CONTROL PLAN FOR ALL SLAB EDGE AND OPENING DIMENSIONS NOT SHOWN, TYPICAL. 3.TOP OF CONCRETE (TOC) = REF ARCH SITE PLAN / CIVIL 4.SLAB THICKNESS = SEE PLAN 5.CONCRETE STRENGTH = REFER TO GENERAL NOTES 6.ALL BUILDING EXTERIOR AND LOAD BEARING WALL SOLE PLATES SHALL BE ANCHORED TO THE CONCRETE FOUNDATION WITH 5/8" DIA x 8" EMBEDMENT ANCHOR BOLTS MINIMUM PER BOARD. ALL NON LOAD BEARING INTERIOR WALLS SHALL HAVE SILL PLATES ATTACHED TO THE FOUNDATION WITH 0.177" DIA x 3 1/4" P.A.F. @ 24" O.C. MAXIMUM. IN ADDITION, FASTENERS FOR PRESERVATIVE-TREATED WOOD SHALL BE AS FOLLOWS: A.UNCOATED IF TREATED WITH SBX/DOT & ZINC BORATE. B.GALVANIZED (ASTM A153) IF TREATED WITH ACQ-C, ACQ-D (CARBONATE), CA-B & CB-A; WITH OR WITHOUT AMMONIA. C.STAINLESS STEEL (TYPE 303, 304, 305, OR 316) IF WOODS HAVE ACTUAL RETENTION LEVELS GREATER THAN 0.40 PSF FOR ACQ, 0.41 PSF FOR CBA A0.21 PSF FOR CA-B (GROUND CONTACT LEVEL). OR ACZA D.ALTERNATIVELY, ALL NON-SHEAR WALL ANCHOR BOLTS AND P.A.F.S MAY BE REPLACED WITH SIMPSON MASA/MASAP MUDSILL ANCHORS @ 24" O.C. (4" MIN DISTANCE) SEE WOOD SHEAR WALL SCHEDULED FOR ANCHORAGE AT SHEAR WALLS. 7.PIPES, CONDUIT, AND OTHER UTILITIES SHALL NOT BE LOCATED WITHIN OR BELOW ANY GRADE BEAM OR FOOTING EXCEPT AS INDICATED ON DETAIL S3.100 8. B/FTG = BOTTOM OF FOOTING ELEVATIONS (BASED ON MINIMUM REQUIRED EMBEDMENT FOR FROST DEPTH) 1/4" = 1'-0"1 Foundation Plan - Garage E / Dogwash • THICKNESS • REINFORCEMENT = • NOTES: SLAB ON GRADE: (N.W. CONCRETE) =4" #3 @ 15" O.C. EA. WAY 1.) REBAR SHALL BE PROPERLY CHAIRED SO IT IS MAINTAINED AT 1/3 THE DEPTH BELOW THE TOP SURFACE DURING CONCRETE PLACEMENT 2.) SLAB TO BE PLACED OVER COMPACTED FILL PER GEOTECH RECOMMENDATIONS GARAGES B/FTG @ GARAGE E = 45'-6" (U.N.O.) No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL). P3.5-11 3-2x12 3-2x12 3-2x12 3-2x12 P3.5-11GTGTGTGTGTGT S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ 3' - 11 3/4"1' - 6"A&H Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:22 PMSG2.210 Wood Framing Plan - Roof - Garage A & H Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Framing Plan - Roof - Garage A & H Wood Beam Schedule Mark Beam / Header 3-2x12 (3) 2x12 P3.5-11 3 1/2 x 11 1/4 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL). P3.5-11 3-2x12 3-2x12 3-2x12 3-2x12 3-2x12GTGTGTGTGTGT2-2x10S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ B&G Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:26 PMSG2.220 Wood Framing Plan - Roof - Garage B & G Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Framing Plan - Roof - Garage B & G Wood Beam Schedule Mark Beam / Header 2-2x10 (2) 2x10 3-2x12 (3) 2x12 P3.5-11 3 1/2 x 11 1/4 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL). P3.5-11 3-2x12 3-2x12 P3.5-11GTGTGTGTGTGT S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ P5-11 C&F Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:32 PMSG2.230 Wood Framing Plan - Roof - Garage C & F Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Framing Plan - Roof - Garage C & F Wood Beam Schedule Mark Beam / Header 3-2x12 (3) 2x12 P3.5-11 3 1/2 x 11 1/4 PSL P5-11 5 1/2 x 11 1/4 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL).GTGTGTGTGTGTS4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______2-2x103-2x123-2x123-2x123-2x12P3.5-11 3-2x12 3-2x12 D Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:40 PMSG2.240 Wood Framing Plan - Roof - Garage D / Maintenance Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Framing Plan - Roof - Garage D / Maintenance Wood Beam Schedule Mark Beam / Header 2-2x10 (2) 2x10 3-2x12 (3) 2x12 P3.5-11 3 1/2 x 11 1/4 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD BEAM / HEADER NOTES: 1. INDICATES BEAM / HEADER, SEE WOOD BEAM / HEADER SCHEDULE MARK WOOD ROOF FRAMING NOTES: 1. ROOF FRAMING TO BE 24" DEEP (MIN) SLOPED TOP OPEN WEB WOOD TRUSSES @ 24" OC MAX UNO. TRUSSES TO BE SPACED AS NEEDED TO AVOID PLUMBING AND IN ACCORDANCE W/ TRUSS DESIGNER. TRUSS MANUFACTURER TO REFERENCE GENERAL NOTES FOR TOTAL DESIGN SUPERIMPOSED DEAD AND LIVE LOADS TO BE APPLIED TO FLOOR AND ROOF TRUSSES. IN ADDITION, TRUSS DESIGNER TO ASSUME 5 PSF OF THE TOTAL SUPERIMPOSED DEAD LOAD IS APPLIED TO TRUSS BOTTOM CHORD. 2. TRUSS DESIGNER TO REF MEP, ARCH, EBM (EXTERIOR BUILDING MAINTENANCE) EQUIPMENT FOR ADDITIONAL ROOF LOADS AND EXACT LOCATION. IN THE ABSENSE OF SPECIFIC LOADING CRITERIA, TRUSS DESIGNER SHALL INCLUDE A DESIGN ALLOWANCE AS FOLLOWS: • AHU'S, BOILERS AND WATER TANKS = 100PSF DL • PHOTO-VOLTAIC (SOLAR) ARRAYS = 8PSF DL • UNSCHEDULED MAINTENANCE TIE-BACKS = 3,100 LBS ASD IMPACT LOAD APPLIED IN ANY DIRECTION 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS, DEPRESSIONS, STEPS, FINISHES, PLATE HEIGHTS AND SPECIFIC/OVERALL BUILDING GEOMETRY WITH THE ARCHITECTURAL DRAWINGS AND NOTIFY ENGINEER AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION START 4. SEE WOOD FRAMING SPECIFICATIONS FOR FLOOR / ROOF SHEATHING AND MINIMUM LUMBER GRADE / SPECIES REQUIREMENTS. 5. SECTIONS CUT ON PLAN SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REFER TO TYPICAL DETAILS/SECTIONS FOR DETAILS / SECTIONS NOT SPECIFICALLY SHOWN OR CUT ON PLAN. 6. SEE ROOF UPLIFT SECTIONS FOR FASTENING OF ROOF LEVEL HEADERS, BEAMS AND GIRDER TRUSSES. 7. AT ROOF UPLIFT ROD LOCATIONS, NUTS SHALL BE RE- TIGHTENED AS REQUIRED PRIOR TO INTERIOR WALL SHEATHING INSTALLATION TO ACCOMMODATE WOOD SHRINKAGE 8. AT LOCATIONS WHERE ROOF UPLIFT RODS COINCIDE WITH SHEAR WALL END ANCHORAGE RODS, ONLY THE SHEAR WALL ANCHORAGE ROD NEED BE INSTALLED. ALL OTHER FASTNENING HARDWARE SHOWN ON THE ROOF UPLIFT DETAILS SHALL BE INSTALLED AS INDICATED. 9. TRUSSES SHALL RECEIVE DOUBLE TOP CHORD AT SPECIFIC DIAPHRAGM STRAPPING LOCATIONS PER PLAN AND NOTES. REFER TO WOOD DIAPHRAGM REINFORCING PLANS FOR MORE INFO. 10. TRUSS SUPPLIER SHALL PROVIDE MECHANICAL CHASES WHERE REQUIRED TO FIT MEP DUCTS AND PIPES THROUGH TRUSS WEB OPENINGS. REFER TO MEP DRAWINGS AND COORDINATE WITH MEP WHERE OPENINGS ARE REQUIRED. 11. SEE THIS SHEET FOR POST/HANGER SCHEDULE. ALL BEAM/HEADER BEARING POINTS NOT NOTED ON PLAN SHALL BE SUPPORTED PER NOTE 4 OF THE POST SCHEDULE. 12. ALL HEADERS BEARING ROOF TRUSSES SHALL BE LOCATED DIRECTLY BELOW THE DOUBLE TOP PLATE UNO. SEE HEADER UPLIFT DETAILS. 13. PROVIDE 3/8" MIN HORIZONTAL GAP BETWEEN EXTERIOR WALL SHEATHING PANELS TO ALLOW FOR SHRINKAGE. GAP TO BE PLACED AT THE LEVEL OF THE FLOOR SHEATHING AT EACH LEVEL, TYP. 14. ROOF TIE-BACK AND EBM ANCHORS, WHERE APPLICABLE, SHALL BE ANCHORD TO ROOF TRUSSES PER TYPICAL DETAILS. TRUSS SUPPLIER SHALL LOCATE ALL ANCHORS PER THE EBM/FACADE ACCESS CONSULTANT DRAWINGS IN COORDINATION WITH THE ARCHITECTURAL DRAWINGS. TRUSS SUPPLIER SHALL DESIGN THE SUPPORTING TRUSSES TO MEET THE LOAD DEMAND(S) SHOWN ON THE TYPICAL DETAILS. 15. AT LOCATIONS WITH PARAPET FRAMING INTENDED TO SUPPORT EBM LOADS SHALL BE REINFORCED PER TYPICAL DETAILS. ALL OTHER LOCATIONS HAVE BEEN DESIGNED TO MEET WIND/SEISMIC LATERAL FORCES ONLY. 16. SEE TYPICAL DETAILS FOR MECHANICAL AND HVAC PLATFORM FRAMING. 17. REFER TO WOOD SHRINKAGE NOTES IN GENERAL NOTES FOR ESTIMATED BUILDING MOVEMENT DUE TO WOOD SHRINKAGE. CONTRACTOR SHALL COORDINATE ESTIMATED VERTICAL MOVEMENT WITH OTHER TRADES AS NEEDED. IN THE ABSENCE OF ESTIMATED BUILDING VERTICAL MOVEMENT, ASSUME 1/4" PER FLOOR. 18. ROOF TRUSSES SHALL BE DESIGNED FOR DRAG LOADS SHOWN ON PLAN. IN THE ABSENSE OF D.F. (DRAG FORCES), ALL TRUSSES PARALLEL TO SHEARWALLS SHALL BE DESIGNED TO RESIST MINIMUM 400 LBS DRAG FORCE (TYPICAL). P3.5-11 3-2x12 3-2x12 3-2x12 3-2x12 3-2x12 2-2x12P3.5-11 GTGTGTGTGTGTS4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ S4.310 .1_______ E 2-2x12 Scale Date Drawn By Checked By Project Number 1/4" = 1'-0"3/18/2026 9:20:44 PMSG2.250 Wood Framing Plan - Roof - Garage E Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Framing Plan - Roof - Garage E / Dogwash Wood Beam Schedule Mark Beam / Header 2-2x12 (2) 2x12 3-2x12 (3) 2x12 P3.5-11 3 1/2 x 11 1/4 PSL No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414.WSW-3WSW-3WSW-3WSW-3WSW-3 A&H SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:20:45 PMSG2.410 Wood Shearwall Plan - Garage A & H Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Shearwall Plan - Level 1 - Garage A & H No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414.WSW-3WSW-3WSW-3WSW-3WSW-3 WSW-3WSW-3 B&G SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:20:50 PMSG2.420 Wood Shearwall Plan - Garage B & G Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Shearwall Plan - Level 1 - Garage B & G No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414.WSW-3WSW-3WSW-3WSW-3WSW-3 C&F SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:20:52 PMSG2.430 Wood Shearwall Plan - Garage C & F Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Shearwall Plan - Level 1 - Garage C & F No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414.WSW-3WSW-3WSW-3WSW-3WSW-3 WSW-3WSW-3 D SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:20:53 PMSG2.440 Wood Shearwall Plan - Garage D / Maintenance Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Shearwall Plan - Level 1 - Garage D / Maintenance No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26 WOOD SHEAR WALL NOTES: 1. SHEAR WALLS SHALL BE SHEATHED AND FASTENED PER THE SHEAR WALL SCHEDULE FROM OUTSIDE FACE OF END POST TO OUTSIDE FACE OF END POST. REFER TO SCHEDULE FOR SIZE AND CONFIGURATION OF END POST MEMBERS. 2. WHERE STAGGERED 4X STUDS OCCUR IN A 6X WALL, SHEAR WALL END POSTS SHALL BE 6X MEMBERS. 3. SHEAR WALL SHEATHING SHALL BE INSTALLED BOTTOM PLATE TO TOP PLATE OF WALL. 4. WHERE SHEAR WALL SHEATHING IS SHOWN TO OCCUR AT UNIT DEMISING WALLS, SHEATHING MAY BE INSTALLED IN AIR GAP PROVIDED THAT FULL AIR GAP IS MAINTAINED BETWEEN SHEATHING AND ADJACENT STUD WALL. 5. SHEAR WALL SHEATHING MAY BE INSTALLED ON EITHER FACE OF A GIVEN WALL WHEN FASTENED DIRECTLY TO STUDS. SHEATHING SHALL BE INSTALLED ON THE OPPOSING SIDE OF WALL AS RESILIENT CHANNELS WHERE OCCURS. 6. CONTINUOUS TIE-DOWN SYSTEM ACTIVATION PINS SHALL BE PULLED AS EACH FLOOR IS FRAMED 7. DO NOT FIRE CAULK TOP OR BOTTOM BEARING PLATES AT END ANCHOR ROD LOCATIONS. 8. SHEARWALLS TO BE ANCHORED WITH CONTINUOUS ROD SYSTEM SEE S5.410 THROUGH S5.414.WSW-3WSW-3WSW-3WSW-3 WSW-3WSW-3WSW-1 E SHEARWALL DIAGRAM - 1 STORY WSW-1 WSW-2 WSW-3 LEVEL WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE WALL TYPE HOLD DOWN TAKE-UP DEVICE LEVEL 5 5 4 4 3 3 2 2 1 B ATR 5/8 N/A D ATR 3/8 N/A D ATR 3/8 N/A 1 Scale Date Drawn By Checked By Project Number As indicated 3/18/2026 9:21:01 PMSG2.450 Wood Shearwall Plan - Garage E / Dogwash Hanover Company Hyannis Phase II Checker Author 10/01/25 25070 55 Wilkens Lane Barnstable, MA 02601 1/4" = 1'-0"1 Wood Shearwall Plan - Level 1 - Garage E / Dogwash No. Description Date 90% Construction Documents 10/01/25 Issue for Conformance 11/21/25 100% IFC 03/18/26