HomeMy WebLinkAboutCOA 199 Harbor Point Revised 5.20SCOPE OF WORK GENERAL NOTES
VICINITY MAPABBREVIATIONS
A AMPERE
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT
(E)EXISTING
ESS ENERGY STORAGE SYSTEM
MSP MAIN SERVICE PANEL
(N)NEW
PRE-FAB PRE-FABRICATED
PSF POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS
V VOLTS
W WATTS
SHEET INDEX
PAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-1.0
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
COVER SHEETREVNAMEDATECOMMENTS
• ALL WORK SHALL GENERALLY CONFORM WITH MA 10TH ED. CMR 780 (2021 IRC/IBC/IEBC), 7-16 ASCE & 2018 NDS,
2023 NEC AND 2023 MA ELECTRICAL CODE 527 CMR 12.00 (2023 NFPA 70 WITH MA AMENDMENTS), MUNICIPAL CODE,
AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS.
• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023.
• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023.
• PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM
COMPLIES WITH 690.41(A)
• MODULES CONFORM TO AND ARE LISTED UNDER UL 61730.
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED.
• RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY
BOUNDARIES PER NEC 690.12(1).
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D).
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
• 11.24 AMPS MODULE SHORT CIRCUIT CURRENT.
• 14.05 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)].
• PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). CONTROLLED CONDUCTORS LOCATED
INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
• THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED
BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A)
• ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8
• SYSTEM SIZE: 4.92KW DC, 3.8KW AC
• MODULES: (12) HANWHA Q-CELLS: Q.PEAK DUO BLK
ML-G10+ 410
• INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
SE3800H-USMN
• ENERGY STORAGE SYSTEM: (1) FRANKLIN: APOWER XYYY
15KWH, 10KW INVERTER OUTPUT, LITHIUM IRON
PHOSPHATE BATTERY (WEIGHT: 357LB EACH)
• MICROGRID INTERCONNECT DEVICE: (1) 280A AGATE X
CONTROL PANEL
• RACKING: ALPHATRACK TO DECK - SNR-DC-00370
PAGE #DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-2.1 ESS ELEVATION
PV-3.0 LAYOUT
PV-4.0 ELECTRICAL
PV-5.0 SIGNAGE
PV-5.1 SIGNAGE 2
2,000.00
This map is for illustration purposes only. It is not
adequate for legal boundary determination or
regulatory interpretation. This map does not represent
an on-the-ground survey. It may be generalized, may not
reflect current conditions, and may contain
cartographic errors or omissions.
Parcel lines shown on this map are only graphic
representations of Assessor’s tax parcels. They are
not true property boundaries and do not represent
accurate relationships to physical objects on the map
such as building locations.
3330167
Feet
feetApprox. Scale: 1 inch =167
Legend
Town of Barnstable GIS Unit
367 Main Street, Hyannis, MA 02601
508-862-4624
gis@town.barnstable.ma.us
Map printed on:4/28/2026
Road Names
PL
PL PLPLPL
PL
PLPL(N) ARRAY AR-01
(N) ARRAY AR-02HARBOR POINT RDPAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-2.0
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
SITE PLAN
MAIN PANEL
DEDICATED PV METER
SERVICE ENTRANCESE
MP
PMSUB-PANELSP
LEGEND SCALE: NTS
NOTE: NOT ALL ITEMS IN LEGEND
WILL APPEAR IN SITE PLAN
ENERGY STORAGE
SYSTEM (ESS)
GP GENERATION PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
INTERIOR EQUIPMENT
SHOWN AS DASHEDINV
AC
DC
METER ADAPTERMABATTERY
BP BACKUP LOADS PANEL MD MICROGRID
INTERCONNECT DEVICE
PV LOAD CENTERLC METER ADAPTER
CONTROLLER
APB FRANKLIN
APBOX
CB IQ COMBINER BOXMAC
RDS REMOTE DISCONNECT
SWITCH
SITE PLAN - SCALE = 1/32" = 1'
NOTES:
·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE
SPRINKLERS.
ARRAY DETAILS:
·TOTAL ROOF SURFACE AREA: 2190 SQ FT.
·TOTAL PV ARRAY AREA: 253.6 SQ FT.
·PERCENTAGE PV COVERAGE:
(TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE
AREA) * 100 = 11.6%
SOLAR
MODULES
SNR MOUNT & SKIRT
SNR MOUNT
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 23°211.36
AR-02 21°42.27116°
TRUE
AZIM
MAG
AZIM
220°206°
130°
(E) RESIDENCE
(E) DETACHED
STRUCTURE
FIRE SETBACKS
(18" TYP)
ROOF PATHWAYS
(3' TYP)
ROOF PATHWAYS
(3' TYP)
ROOF PATHWAYS
(3' TYP)
DRIVEWAY
SE
MP
INV
MD
AC
AC RDS
AC
EXTERIOR SOUTH WALL (TYP)
3' min
3' min FRANKLINFIRE RESISTIVE
SEPARATION
3'-9"
2'-6"
solaredge
PAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-2.1
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
ESS ELEVATION
NOTE:
·FIRE RESISTIVE SEPARATION TO BE
INSTALLED BETWEEN THE BATTERY
MOUNTING BRACKET AND THE SUPPORTING
WALL. THE FIRE BARRIER THICKNESS SHALL
NOT EXCEED 3/4"
SITE PLAN - SCALE = NTS
NOTES:
·ENERGY STORAGE SYSTEM TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS AND LISTING REQUIREMENTS'
·ENERGY STORAGE UNIT TO BE INSTALLED ON THE EXTERIOR OF BUILDING
·ENERGY STORAGE UNIT TO BE INSTALLED MINIMUM 3 FEET AWAY FROM ANY WINDOW
AND/OR DOOR ENTERING THE DWELLING
·FIRE DETECTION REGULATION NOT APPLICABLE DUE TO EXTERIOR INSTALLATION
·IMPACT PROTECTION NOT REQUIRED DUE TO LOCATION NOT AT RISK OF VEHICLE DAMAGE
PAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-3.0
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
LAYOUT
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 30 PSF
WIND SPEED:
130 MPH 3-SEC GUST.
FASTENERS:
(2) DECK ANCHORS FULLY
PENETRATING THROUGH WOOD
DECK
STRUCTURAL NOTES
• ATTACHMENTS FOR THIS INSTALLATION ARE DESIGNED FOR A STANDARD WOOD
FRAMED ROOF STRUCTURE FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION
THAT WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY. INSTALLERS SHALL
OBSERVE THE FRAMING FOR CONFORMANCE TO THE BELOW REQUIREMENTS AND
NOTIFY THE ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES FOR GUIDANCE
PRIOR TO PROCEEDING WITH INSTALLATION.
ⅰ: MINIMUM 2x WOOD FRAMING (NOMINAL) FREE FROM DAMAGE, DETERIORATION, OR
MODIFICATION
ⅱ: FRAMING SPACING AT 24"" O.C. MAX
ⅲ: FASTENER SHALL BE EMBEDDED INTO COMPETENT MATERIAL
• IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR TILT KITS) BOUNDARY REGION OF
ANY ROOF PLANE EDGES (EXCEPT VALLEYS),
THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12"
(48" FOR TILT KITS) BOUNDARY REGION ONLY AS
FOLLOWS:
•• ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%.
•• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE
ATTACHMENT SPACING INDICATED ON PLANS.
• INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES
OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION.
ROOF INFO ATTACHMENT INFORMATION
Name Type Height Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-01 COMP SHINGLE - ALPHATRACK [DECKANCHOR]2-STORY ALPHATRACK TO DECK - SNR-DC-00370 3'-0"0'-6"1'-8"0'-6"STAGGERED
AR-02 COMP SHINGLE - ALPHATRACK [DECKANCHOR]2-STORY ALPHATRACK TO DECK - SNR-DC-00370 3'-0"0'-6"1'-8"0'-6"STAGGERED
D1 - AR-01 - SCALE: 1/8" = 1'-0"
AZIM: 206°
PITCH: 23°
D2 - AR-02 - SCALE: 1/8" = 1'-0"
AZIM: 116°
PITCH: 21°
24'-9"
10'-5"
5'-8"3'-3"
1'-8"
4'-2"
13'-11"
6'-2"
22'-8"4'-1"
2'-6"
3'-11"
M
(N) REMOTE
DISABLE SWITCHCTRLMCOM1
NEW 280A
FRANKLIN AGATE X
WITH 100A A
MAIN BREAKER
60A ESS
BREAKER
20A PV BREAKER
6
B SOLAREDGE TECHNOLOGIES
SE3800H-USMN 3800 WATT INVERTER
LOAD RATED DC
DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT
3
J-BOX
1 12 HANWHA Q-CELLS
Q.PEAK DUO BLK ML-G10+ 410
STRING 1 WITH 12 MODULES
(WITH U650 OPTIMIZERS)
2
• POINT OF INTERCONNECTION: NEC 2023 705.12(B)(2), LOAD BREAKER AT OPPOSITE END OF BUSBAR
• METER NUMBER:2284630
• EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS
• NOTE: TOTAL SYSTEM BACKFEED = 80.0A USED FOR INTERCONNECTION CALCULATIONS
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A, 2P
120/240VAC
3
A
A
5
EXISTING 100/100A
BACKUP LOADS PANEL
(E) BACKUP LOADS 4
4
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A, 2P
120/240VAC
ENERGY STORAGE SYSTEM
APOWER XYYY
B
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU323RB
3R, 100A, 3P
120/240VAC
6
CONDUIT SCHEDULE
TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT
1 Inverter Input (2) 10 AWG (PV WIRE)N/A 10 AWG (BARE)Open Air
2 Inverter Input (2) 10 AWG
THHN/THWN-2 N/A 10 AWG THHN/THWN-2 3/4 EMT
3 Inverter Output (2) 10 AWG
THHN/THWN-2
(1) 10 AWG
THHN/THWN-2 10 AWG THHN/THWN-2 3/4 EMT
4 Battery Output (2) 6 AWG
THHN/THWN-2
(1) 6 AWG
THHN/THWN-2 10 AWG THHN/THWN-2 3/4 EMT
5 Backup panel Feeder (2) 3 AWG
THHN/THWN-2
(1) 3 AWG
THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT
6 Service Feeder (2) 3 AWG
THHN/THWN-2
(1) 3 AWG
THHN/THWN-2 NONE 1 EMT
PAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-4.0
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
ELECTRICAL
INSTALLER MUST CHECK THE CONDITION,
INSTALLABILITY AND CODE COMPLIANCE OF
EXISTING EQUIPMENT.
PAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-5.0
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
SIGNAGE
LABEL LOCATION:
MAIN SERVICE DISCONNECT
For customer questions or service issues, call our Customer Care team at:
1.833.607.6937 ext. 0
*Prior authorization from Sunrun is required for any maintenance/service activity.HIC 180120
Emergency responders, for 24 hour emergency service call:
1.855.478.6786
911
For customers in case of emergency, call:
This solar PV system is owned and operated by:
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2023: 705.12(B)(2)
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR
ELECTRIC PV
PANELS
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN PV
SYSTEM AND REDUCE SHOCK
HAZARD IN THE ARRAY.
4"
3"
PER CODE(S): NEC 2023: 690.12(D)
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
!
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S),
AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2023: 690.13(B),
705.20(7), 706.15(C)
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2023: 690.12(D)(2), IFC
2021: 1204.5.3
INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC480
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2023: 690.7(D)
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2023: 690.31(D)(2)
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2023: 705.10, 705.30(C),
706.21(A)
NOMINAL ESS VOLTAGE VAC
LABEL LOCATION:
ENERGY STORAGE SYSTEM
PER CODE(S): NEC 2023: 706.15(C)
120/240
ENERGY STORAGE SYSTEM DISCONNECT
ENERGY STORAGE SYSTEM
PREMISES WIRING MAY REMAIN
ENERGIZED AFTER LOSS OF
UTILITY POWER
CAUTION!
LABEL LOCATION:
INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2023: 706.15(C)
PAGE
REV: A3 5/18/2026
CATHERINE LEDEC
199 HARBOR POINT RD,
BARNSTABLE, MA, 02631
PROJECT NUMBER:
223R-199LEDE PR-3004900220
SHEET
DESIGNER:
NICODEME KWIHANGANA
CUSTOMER RESIDENCE:
TEL. (703) 346-0814
APN: NONE
(415) 580-6920 ex3
PV-5.1
#ESTAMP#SSTAMP
695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331
PHONE 978-872-4294
FAX 303 557 6199
#180120
SIGNAGE 2
LABELING FORMAT
LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS
MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR
THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE.
CAUTION:
199 HARBOR POINT RD, BARNSTABLE, MA, 02631
MULTIPLE SOURCES OF POWER
PER CODE(S): NEC 2023 : 705.10(2)
SOLAR PANELS ON ROOF
MAIN PANEL (INT)
SERVICE ENTRANCE
AC DISCONNECT
SYSTEM SHUTDOWN
DISCONNECT
2 AC DISCONNECT