Loading...
HomeMy WebLinkAboutCOA 199 Harbor Point Revised 5.20SCOPE OF WORK GENERAL NOTES VICINITY MAPABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM MSP MAIN SERVICE PANEL (N)NEW PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS V VOLTS W WATTS SHEET INDEX PAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-1.0 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 COVER SHEETREVNAMEDATECOMMENTS • ALL WORK SHALL GENERALLY CONFORM WITH MA 10TH ED. CMR 780 (2021 IRC/IBC/IEBC), 7-16 ASCE & 2018 NDS, 2023 NEC AND 2023 MA ELECTRICAL CODE 527 CMR 12.00 (2023 NFPA 70 WITH MA AMENDMENTS), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. • PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41(A) • MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 11.24 AMPS MODULE SHORT CIRCUIT CURRENT. • 14.05 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION • THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A) • ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8 • SYSTEM SIZE: 4.92KW DC, 3.8KW AC • MODULES: (12) HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 410 • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: SE3800H-USMN • ENERGY STORAGE SYSTEM: (1) FRANKLIN: APOWER XYYY 15KWH, 10KW INVERTER OUTPUT, LITHIUM IRON PHOSPHATE BATTERY (WEIGHT: 357LB EACH) • MICROGRID INTERCONNECT DEVICE: (1) 280A AGATE X CONTROL PANEL • RACKING: ALPHATRACK TO DECK - SNR-DC-00370 PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-2.1 ESS ELEVATION PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-5.1 SIGNAGE 2 2,000.00 This map is for illustration purposes only. It is not adequate for legal boundary determination or regulatory interpretation. This map does not represent an on-the-ground survey. It may be generalized, may not reflect current conditions, and may contain cartographic errors or omissions. Parcel lines shown on this map are only graphic representations of Assessor’s tax parcels. They are not true property boundaries and do not represent accurate relationships to physical objects on the map such as building locations. 3330167 Feet feetApprox. Scale: 1 inch =167 Legend Town of Barnstable GIS Unit 367 Main Street, Hyannis, MA 02601 508-862-4624 gis@town.barnstable.ma.us Map printed on:4/28/2026 Road Names PL PL PLPLPL PL PLPL(N) ARRAY AR-01 (N) ARRAY AR-02HARBOR POINT RDPAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-2.0 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 SITE PLAN MAIN PANEL DEDICATED PV METER SERVICE ENTRANCESE MP PMSUB-PANELSP LEGEND SCALE: NTS NOTE: NOT ALL ITEMS IN LEGEND WILL APPEAR IN SITE PLAN ENERGY STORAGE SYSTEM (ESS) GP GENERATION PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) INTERIOR EQUIPMENT SHOWN AS DASHEDINV AC DC METER ADAPTERMABATTERY BP BACKUP LOADS PANEL MD MICROGRID INTERCONNECT DEVICE PV LOAD CENTERLC METER ADAPTER CONTROLLER APB FRANKLIN APBOX CB IQ COMBINER BOXMAC RDS REMOTE DISCONNECT SWITCH SITE PLAN - SCALE = 1/32" = 1' NOTES: ·RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: ·TOTAL ROOF SURFACE AREA: 2190 SQ FT. ·TOTAL PV ARRAY AREA: 253.6 SQ FT. ·PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 11.6% SOLAR MODULES SNR MOUNT & SKIRT SNR MOUNT ARRAY PITCH PV AREA (SQFT) AR-01 23°211.36 AR-02 21°42.27116° TRUE AZIM MAG AZIM 220°206° 130° (E) RESIDENCE (E) DETACHED STRUCTURE FIRE SETBACKS (18" TYP) ROOF PATHWAYS (3' TYP) ROOF PATHWAYS (3' TYP) ROOF PATHWAYS (3' TYP) DRIVEWAY SE MP INV MD AC AC RDS AC EXTERIOR SOUTH WALL (TYP) 3' min 3' min FRANKLINFIRE RESISTIVE SEPARATION 3'-9" 2'-6" solaredge PAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-2.1 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 ESS ELEVATION NOTE: ·FIRE RESISTIVE SEPARATION TO BE INSTALLED BETWEEN THE BATTERY MOUNTING BRACKET AND THE SUPPORTING WALL. THE FIRE BARRIER THICKNESS SHALL NOT EXCEED 3/4" SITE PLAN - SCALE = NTS NOTES: ·ENERGY STORAGE SYSTEM TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND LISTING REQUIREMENTS' ·ENERGY STORAGE UNIT TO BE INSTALLED ON THE EXTERIOR OF BUILDING ·ENERGY STORAGE UNIT TO BE INSTALLED MINIMUM 3 FEET AWAY FROM ANY WINDOW AND/OR DOOR ENTERING THE DWELLING ·FIRE DETECTION REGULATION NOT APPLICABLE DUE TO EXTERIOR INSTALLATION ·IMPACT PROTECTION NOT REQUIRED DUE TO LOCATION NOT AT RISK OF VEHICLE DAMAGE PAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-3.0 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 LAYOUT DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 30 PSF WIND SPEED: 130 MPH 3-SEC GUST. FASTENERS: (2) DECK ANCHORS FULLY PENETRATING THROUGH WOOD DECK STRUCTURAL NOTES • ATTACHMENTS FOR THIS INSTALLATION ARE DESIGNED FOR A STANDARD WOOD FRAMED ROOF STRUCTURE FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN INTEGRITY. INSTALLERS SHALL OBSERVE THE FRAMING FOR CONFORMANCE TO THE BELOW REQUIREMENTS AND NOTIFY THE ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES FOR GUIDANCE PRIOR TO PROCEEDING WITH INSTALLATION. ⅰ: MINIMUM 2x WOOD FRAMING (NOMINAL) FREE FROM DAMAGE, DETERIORATION, OR MODIFICATION ⅱ: FRAMING SPACING AT 24"" O.C. MAX ⅲ: FASTENER SHALL BE EMBEDDED INTO COMPETENT MATERIAL • IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR TILT KITS) BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" (48" FOR TILT KITS) BOUNDARY REGION ONLY AS FOLLOWS: •• ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. •• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. • INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. ROOF INFO ATTACHMENT INFORMATION Name Type Height Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 COMP SHINGLE - ALPHATRACK [DECKANCHOR]2-STORY ALPHATRACK TO DECK - SNR-DC-00370 3'-0"0'-6"1'-8"0'-6"STAGGERED AR-02 COMP SHINGLE - ALPHATRACK [DECKANCHOR]2-STORY ALPHATRACK TO DECK - SNR-DC-00370 3'-0"0'-6"1'-8"0'-6"STAGGERED D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 206° PITCH: 23° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 116° PITCH: 21° 24'-9" 10'-5" 5'-8"3'-3" 1'-8" 4'-2" 13'-11" 6'-2" 22'-8"4'-1" 2'-6" 3'-11" M (N) REMOTE DISABLE SWITCHCTRLMCOM1 NEW 280A FRANKLIN AGATE X WITH 100A A MAIN BREAKER 60A ESS BREAKER 20A PV BREAKER 6 B SOLAREDGE TECHNOLOGIES SE3800H-USMN 3800 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI RAPID SHUTDOWN COMPLIANT 3 J-BOX 1 12 HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 410 STRING 1 WITH 12 MODULES (WITH U650 OPTIMIZERS) 2 • POINT OF INTERCONNECTION: NEC 2023 705.12(B)(2), LOAD BREAKER AT OPPOSITE END OF BUSBAR • METER NUMBER:2284630 • EQUIPMENT CHARACTERISTICS INCLUDED IN SPEC SHEETS • NOTE: TOTAL SYSTEM BACKFEED = 80.0A USED FOR INTERCONNECTION CALCULATIONS (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC 3 A A 5 EXISTING 100/100A BACKUP LOADS PANEL (E) BACKUP LOADS 4 4 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A, 2P 120/240VAC ENERGY STORAGE SYSTEM APOWER XYYY B (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU323RB 3R, 100A, 3P 120/240VAC 6 CONDUIT SCHEDULE TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT 1 Inverter Input (2) 10 AWG (PV WIRE)N/A 10 AWG (BARE)Open Air 2 Inverter Input (2) 10 AWG THHN/THWN-2 N/A 10 AWG THHN/THWN-2 3/4 EMT 3 Inverter Output (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 10 AWG THHN/THWN-2 3/4 EMT 4 Battery Output (2) 6 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 10 AWG THHN/THWN-2 3/4 EMT 5 Backup panel Feeder (2) 3 AWG THHN/THWN-2 (1) 3 AWG THHN/THWN-2 8 AWG THHN/THWN-2 1 EMT 6 Service Feeder (2) 3 AWG THHN/THWN-2 (1) 3 AWG THHN/THWN-2 NONE 1 EMT PAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-4.0 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 ELECTRICAL INSTALLER MUST CHECK THE CONDITION, INSTALLABILITY AND CODE COMPLIANCE OF EXISTING EQUIPMENT. PAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-5.0 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 SIGNAGE LABEL LOCATION: MAIN SERVICE DISCONNECT For customer questions or service issues, call our Customer Care team at: 1.833.607.6937 ext. 0 *Prior authorization from Sunrun is required for any maintenance/service activity.HIC 180120 Emergency responders, for 24 hour emergency service call: 1.855.478.6786 911 For customers in case of emergency, call: This solar PV system is owned and operated by: NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2023: 705.12(B)(2) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. 4" 3" PER CODE(S): NEC 2023: 690.12(D) ELECTRICAL SHOCK HAZARD WARNING TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2023: 690.13(B), 705.20(7), 706.15(C) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2023: 690.12(D)(2), IFC 2021: 1204.5.3 INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC480 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2023: 690.7(D) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2023: 690.31(D)(2) WARNING! SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM THREE POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2023: 705.10, 705.30(C), 706.21(A) NOMINAL ESS VOLTAGE VAC LABEL LOCATION: ENERGY STORAGE SYSTEM PER CODE(S): NEC 2023: 706.15(C) 120/240 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM PREMISES WIRING MAY REMAIN ENERGIZED AFTER LOSS OF UTILITY POWER CAUTION! LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2023: 706.15(C) PAGE REV: A3 5/18/2026 CATHERINE LEDEC 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 PROJECT NUMBER: 223R-199LEDE PR-3004900220 SHEET DESIGNER: NICODEME KWIHANGANA CUSTOMER RESIDENCE: TEL. (703) 346-0814 APN: NONE (415) 580-6920 ex3 PV-5.1 #ESTAMP#SSTAMP 695 MYLES STANDISH BLVD, TAUNTON, MA, 02780-7331 PHONE 978-872-4294 FAX 303 557 6199 #180120 SIGNAGE 2 LABELING FORMAT LABELS SHALL BE RED PLASTIC MATERIAL WITH ENGRAVED WHITE LETTERS MADE OF DURABLE ADHESIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. LETTERS SHALL BE MINIMUM 3/8" IN SIZE. CAUTION: 199 HARBOR POINT RD, BARNSTABLE, MA, 02631 MULTIPLE SOURCES OF POWER PER CODE(S): NEC 2023 : 705.10(2) SOLAR PANELS ON ROOF MAIN PANEL (INT) SERVICE ENTRANCE AC DISCONNECT SYSTEM SHUTDOWN DISCONNECT 2 AC DISCONNECT