Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
11 WINGSTOP
Town of Barnstable, MA May 22, 2026 Record No: CV-147 Common Victualler License Status: Active Submitted On: 4/3/2026 Primary Location 451 IYANNOUGH ROAD/RTE 28 Hyannis, MA 02601 Owner AIRVIEW LLC 297 NORTH STREET HYANNIS, MA 02601 Business Information Name of Business/Corporation:* WS Hyannis LLC Doing Business As:* Wingstop FEIN* 41-2773476 Does the Business Mailing Address differ from the selected Location Address?* Yes Business Mailing Address Street:* 10 East 33rd Street 8th Floor City:* New York State:* New york Zip:* 10016 Manager Name:* Steven Tate Manager Phone:* Manager Email:* Annual/Seasonal Annual is January 1st through December 31st. Seasonal is April 1st through January 15th Annual/Seasonal* Annual Restaurant Details Type of Seating Available:* Indoor Only Seating Number of Seats Inside:* 30 Total Seating Capacity: Entertainment: Entertainment Licenses are for both Live and Non-Live Entertainment. Non-Live Entertainment include: Cinema, Light Show, Pool Tables, Coin-Op Machines, Video Games, Jukebox, Music Video, Recorded Music, TV's Do you have Entertainment?* No Hours of Operation - Food Sunday Food Service Hours:* 10:30 am - 12 am Monday Food Service Hours:* 10:30 am - 12 am 30 Tuesday Food Service Hours:* 10:30 am - 12 am Wednesday Food Service Hours:* 10:30 am -12 am Thursday Food Service Hours:* 10:30 am - 12 am Friday Food Service Hours:* 10:30 am - 12 am Saturday Food Service Hours:* 10:30 am - 12 am Application Signature: Applicant Signature* Marina Roulis Apr 3, 2026 Delaware The First State Page 1 10414679 8100 Authentication: 205419992 SR# 20254659519 Date: 11-24-25 You may verify this certificate online at corp.delaware.gov/authver.shtml I, CHARUNI PATIBANDA-SANCHEZ, SECRETARY OF STATE OF THE STATE OF DELAWARE, DO HEREBY CERTIFY THE ATTACHED IS A TRUE AND CORRECT COPY OF THE CERTIFICATE OF FORMATION OF “WS HYANNIS, LLC”, FILED IN THIS OFFICE ON THE TWENTY-FOURTH DAY OF NOVEMBER, A.D. 2025, AT 2:15 O`CLOCK P.M. KEY NOTES:GENERAL NOTES: 18x6018x60 18x60 18x60 20x3620x3620x48 24x3620x3620x48 20x3620x4824x48 24x36 18x36 18x4818x4818x48 18x3618x48EXTEND NEW 4" SANITARY PIPING AND CONNECT TO EXISTING SANITARY MAIN BEHIND BUILDING. FIELD VERIFY EXISTING SANITARY PIPING LOCATION, INVERT, AND FLOW DIRECTION PRIOR TO START OF WORK. EXTEND NEW 4" GREASE WASTE PIPING AND CONNECT TO EXISTING GREASE WASTE MAIN CONNECTED TO EXISTING 2,000 GALLON GREASE INTERCEPTOR. COORDINATE ROUTING IN FIELD. EXISTING SANITARY PIPING. SHOWN FOR REFERENCE. EXISTING GREASE WASTE PIPING. FIELD VERIFY EXISTING GREASE WASTE PIPING LOCATION, INVERT, AND FLOW DIRECTION PRIOR TO START OF WORK. 1 2 3 4 A. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE THEMSELVES WITH ALL REQUIREMENTS OF THE PROJECT AND NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES FOUND. THIS SHALL BE DONE PRIOR TO BID TO PREVENT UNKNOWN ADDITIONAL COSTS TO THE OWNER. B. THE WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING SPECIFICATION AND WITH THE LATEST EDITION OF THE PREVAILING STATE PLUMBING AND BUILDING CODES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY. C. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES BEFORE PROCEEDING WITH INSTALLATION. D. ANY CHANGES AND OR UPGRADE TO TENANT'S EXISTING PLUMBING SYSTEMS SHALL COMPLY WITH ALL CODES AND MALL CRITERIA. EXISTING SYSTEMS SHALL POSSESS THE CAPACITY TO HANDLE ANY AND ALL CHANGES IN LOAD. E. BEFORE CORE DRILLING OR CHANNELING THE FLOOR SLAB, THE CONTRACTOR SHALL SCAN (X-RAY OR GROUND PENETRATING RADAR) THE AREA UNDER CONSTRUCTION FOR PIPES, CONDUIT, ETC. HIDDEN WITHIN OR BELOW THE SLAB. ANY DAMAGE TO EXISTING TO REMAIN SERVICES TO BE REPAIRED AT CONTRACTOR EXPENSE. F. COORDINATE WITH PROPERTY MANAGEMENT PRIOR TO REMOVAL OF ALL EXISTING FLOOR SLAB AND THE CONNECTION BETWEEN NEW AND EXISTING SERVICES. G. REFER TO THE ARCHITECTURAL DRAWINGS FOR WALL ELEVATIONS FOR MOUNTING HEIGHTS FOR ALL PLUMBING FIXTURES. H. ALL SHUTOFF VALVES SHALL BE ACCESSIBLE. DO NOT LOCATE ANY VALVES ABOVE DUCTWORK, ELECTRICAL CONDUIT, CABLE TRAYS OR PIPING THAT WOULD MAKE THE VALVES INACCESSIBLE OR UNABLE TO VISUALLY SEE THE VALVES LOCATION. LOCATE THE BRANCH SHUTOFF VALVES AS CLOSE AS POSSIBLE TO THE BRANCH CONNECTION TO THE MAIN SERVICE WHILE MAINTAINING THE VALVE ACCESSIBILITY. ABOVE CEILING VALVES TO BE LOCATED NEAR CEILING ACCESS PANELS. I. THE PLUMBING CONTRACTOR TO PROVIDE ALL PIPING, SINK TAILPIECES, SINK DRAIN FITTINGS, AND ALL OTHER MISC FITTINGS AS REQUIRED. J. PROVIDE DEEP SEAL P-TRAP FOR ALL FLOOR DRAINS. K. PROVIDE ADDITIONAL FLOOR CLEANOUTS OR WALL CLEANOUTS AS DIRECTED BY THE ADMINISTRATIVE AUTHORITY. L. INSTALL BALL VALVES ON ALL BRANCH SUPPLY LINES. M. INSULATE ALL EXPOSED PIPING UNDER CABINETS AND LAVATORY SINKS. NOTE TO CONTRACTOR: THE LOCATION OF THE GREASE TRAP AS SHOWN IS FOR COORDINATION PURPOSES ONLY. THE CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS DURING THE BIDDING PHASE OF THIS PROJECT AND ASSIGN ALL APPLICABLE COST. WHEN NOT INDICATED, VERIFY WITH LOCAL AHJ IF ADDITIONAL SAMPLING PORT OR SAMPLE TEE IS REQUIRED. 3" V UP 2" V UP 2" V UP 2" V UP 2" GW UP 2" V UP 2" GW UP 2" V UP 2" V UP 2" V UP 2" W UP 3" W UP 4" GW UP TO FCO 4" GW UP TO FCO 4" GW UP TO FCO 4" W UP TO FCO 2" W UP 4" W UP TO FCO W GW4" W4" W4" GW4" W4" GW4" GW4" GW 4" GW4" GW2" GW 3" W4" W 4" W 4" W2 3 1 4" W UP TO FCO UP TO EX. CO 2" V UP 3" W 4 SEAL SHEET NUMBER REVISION DATE ISSUE DATE TITLE PROJECT NO. DRAWN BY CHECKED BY PROJECT INFORMATION CONSULTANT 2801 NORTH CENTRAL EXPRESSWAY, SUITE 1600 DALLAS, TX 75204 TELEPHONE: (972) 686-6500 FAX: (972) 686-6502 THESE DRAWINGS, IDEAS, SPECIFICATIONS AND DESIGNS ARE EXCLUSIVE PROPERTY OF WINGSTOP RESTAURANTS, INC. NO PART OF THESE DRAWINGS MAY BE COPIED, REPRODUCED, OR OTHER STRUCTURES BUILT FROM SUCH WITHOUT THE WRITTEN CONSENT OF WINGSTOP RESTAURANTS, INC. COPYRIGHT 2025 WINGSTOP RESTAURANTS, INC. ALL RIGHTS RESERVED © Project No.: 0426741-021 DISCLAIMER: P0.1 2025-10-28 0425741-021 TSB GMS DESIGN INTENT REVIEW PERMIT SET 2025-11-07AIRPORT ROTARY451 IYANNOUGH RD, SUITE BHYANNIS, MA. 02601WINGSTOP(GL#AC538)UNDERFLOOR PLUMBING PLAN NG_TRAD_2025.01 1/4" = 1'-0" 1 UNDERFLOOR PLUMBING PLAN Digitally signed by Gregory M Steinmetz DN: CN=Gregory M Steinmetz, dnQualifier=A01410D0000018801BBF72E00002AE8, O=Wisconsin, C=US Date: 2025.11.07 14:09:09-06'00'