Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AP-2026-024 Plans
UP PROPERTY LINE PHIN N E Y ' S L A N E ATTUCKS LANE PROPOSED SHED 10' x 20' EXISTING GARBAGE ENCLOSURE 123456789101112 13 EXISTING ACCESSIBLE WOOD WALKWAY TO REMAIN 141516171819202122 2324252627EXISTING CURB CUTS TO REMAIN RE-STRIPE ACCESS AISLE AND (5) PARKING SPACES. PAINT ACCESSIBLE LOGO ON PAVEMENT EXI S T I N G A S P H A L T DRI V E A N D PA R K I N G L O T 41' - 0"102' - 0"57' - 0 " 60 ' - 0 " EXISTING BUILDING 5,580 GSF S 43°31'53" E 310.00'S 49°28'07" W 217.62'A= 57.99' R=760.00'N 4 0 ° 3 1 ' 5 1 " E 6 2 ' N 3 1 ° 3 0 ' 5 1 " E 7 1 . 9 3 ' A= 208.05' R=162.28 A= 35.47' R=1877.00'NEW METAL HANDRAIL WITH EPOXY PAINT NEW METAL HANDRAIL WITH EPOXY PAINT NE W T R A D I T I O N A L L I G H T FIX T U R E S O N P O S T REGRADE NEGATIVE SLOPE WITH ADDED PEA STONE AND NEW LOW LYING PLANTINGS APROX. 1,600 SF (ALLOWANCE) RUN DRAINAGE PIPE TO DRY WELL 150 LONGWATER DRNORWELL, MA 0206143 HARVARD ST WORCESTER, MA 01609781.871.9804habeebarch.comA R C H I T E C T SH A B E E B& A S S O C I A T E SSCALE: PROJECT NO: DATE: DRAWN BY: CHECKED BY:PLOTTED ON:43 2 1 12 3 4 B C AThis Border is intended for a 22" x 34" sheet. If printed sheet size differs, refer to graphic bar scales only.AS NOTED © Copyright 2024 Habeeb & Associates Architects7/16/2026 1:13:48 PMA-001 ARCHITECTURAL SITE PLAN 2429.01 07/16/26 NSA SB 1330 PHINNEY'S LANEHYANNIS, MA 02601CAPE COD COMMISSIONOFFICE RENOVATION0 10'20'40' SCALE: 1" = 20'-0" 1 PROPOSED SITE PLAN OCCUPANCY COUNT: PER IBC 2021 TABLE 1004 MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT BUSINESS: 1 OCC. PER 150 GSF 4,960 GSF / 150 = 33 OCCUPANTS ASSEMBLY: 1 OCC. PER 15 NET 6,20 GSF / 15 = 41 OCCUPANTS TOTAL: 74 OCCUPANTS PARKING REQUIREMENTS: PER TOWN OF BARNSTABLE ZONING CODE ARTICLE VI, SUBSECTION 250-56, OFFICE USE BUILDINGS REQUIRE ONE PARKING SPACE PER EACH 300 GSF FLOOR AREA PLUS ONE SPACE FOR EACH SEPARATE SUITE. 5,580 GSF EXISTING BUILDING AREA / 300 = 19 SPACES REQUIRED. MA ARCHITECTURAL ACCESS BOARD (MAAB) REQUIRES (2) ACCESSIBLE SPACES FOR LOTS CONTAINING 26-50 SPACES, A MINIMUM OF ONE VAN-ACCESSIBLE SPACE MUST BE PROVIDED. EXISTING LOT: 28 PARKING SPACES INCLUDING (2) DESIGNATED ACCESSIBLE SPACES. PROPOSED LOT: 27 PARKING SPACES INCLUDING (1) VAN-ACCESSIBLE PARKING SPACE AND (1) ACCESSIBLE PARKING SPACE. COMMUNITY PANEL NUMBER: 250001 0005 C ASSESSORS MAP: MAP: 274 PARCEL: 16.B02 PLAN SOURCE: FOUNDATION CERTIFICATION PLAN PREPARED BY BAXTER, NYE & HOLMGREN, INC. DATED JUNE 23, 2000 TRUE NORTH REVISIONS Δ MM-DD-YYYY DESCRIPTION GENERAL NOTES: BASE BID FOR EXTERIOR BUILDING WORK - NEW SHINGLE ROOFING. SEE ROOF PLAN - NEW 1x8 COMPOSITE FASCIA - PATCH, REPAIR, PREP AND PAINT ALL WOOD TRIM SEE PHOTOS A/201 FOR SPECIFIC REPAIRS - POWER WASH VINYL SIDING (APPROX. 2,680 SF) -POWER WASH AND RE-STAIN CEDAR SHINGLES ALTERNATE #1 - PROVIDE GLASS PARTITION/DOOR SYSTEM AT THE SOUTH CORRIDOR AS SHOWN ON SHEET A-121 AND FRAMING MODIFICATIONS AS SHOWN ON THE STRUCTURAL PLANS. ALTERNATE #2 - PROVIDE AN ALL-ELECTRIC HVAC SYSTEM PER MECHANICAL SPECIFICATIONS. ALTERNATE #3 - REMOVE ALL EXTERIOR SIDING AND REPLACE WITH PAINTED BORAL CLAPBOARD SIDING. REPLACE ALL WOOD TRIM WITH COMPOSITE TRIM WITH PROFILES AND SIZES TO MATCH EXISTING. ALTERNATE #4 - REMOVE/REPLACE ALL EXISTING WINDOWS FOR ALUMINUM-CLAD WINDOWS TELELEC 6"6" LU/LA LIFT 1 HOUR SHAFT WALL CONSTRUCTION AND CONCRETE ELEVATOR PIT BASEMENT SLAB ON GRADE ABOVE EXISTING STAIR TO REMAIN PATCH AND SEAL SLAB AS REQUIRED AT REMOVED STUD WALL NEW FOOTING SEE STRUCTURAL PATCH CONCRETE SLAB AT NEW FOOTING AND AS REQUIRED AROUND NEW ELEVATOR PIT FE SDT MACHINE ROOM 1 HOUR FIRE RATED MACHINE ROOM 5' - 11"5' - 4"WALL LEGEND EXISTING WALLS - TO REMAIN NEW WALL - TO BE CONSTRUCTED DOOR LEGEND EXISTING DOOR - TO REMAIN NEW DOOR - TO BE INSTALLED 150 LONGWATER DRNORWELL, MA 0206143 HARVARD ST WORCESTER, MA 01609781.871.9804habeebarch.comA R C H I T E C T SH A B E E B& A S S O C I A T E SSCALE: PROJECT NO: DATE: DRAWN BY: CHECKED BY:PLOTTED ON:43 2 1 12 3 4 B C AThis Border is intended for a 22" x 34" sheet. If printed sheet size differs, refer to graphic bar scales only.AS NOTED © Copyright 2024 Habeeb & Associates Architects7/16/2026 1:13:49 PMA-110 BASEMENT PLAN - NEW WORK 2429.01 07/16/26 NSA SB 1330 PHINNEY'S LANEHYANNIS, MA 02601CAPE COD COMMISSIONOFFICE RENOVATION0 2'4'8' SCALE: 3/16" = 1'-0" 1 BASEMENT - NEW WORK TRUE NORTH REVISIONS Δ MM-DD-YYYY DESCRIPTION GENERAL NOTES: BASE BID FOR EXTERIOR BUILDING WORK - NEW SHINGLE ROOFING. SEE ROOF PLAN - NEW 1x8 COMPOSITE FASCIA - PATCH, REPAIR, PREP AND PAINT ALL WOOD TRIM SEE PHOTOS A/201 FOR SPECIFIC REPAIRS - POWER WASH VINYL SIDING (APPROX. 2,680 SF) -POWER WASH AND RE-STAIN CEDAR SHINGLES ALTERNATE #1 - PROVIDE GLASS PARTITION/DOOR SYSTEM AT THE SOUTH CORRIDOR AS SHOWN ON SHEET A-121 AND FRAMING MODIFICATIONS AS SHOWN ON THE STRUCTURAL PLANS. ALTERNATE #2 - PROVIDE AN ALL-ELECTRIC HVAC SYSTEM PER MECHANICAL SPECIFICATIONS. ALTERNATE #3 - REMOVE ALL EXTERIOR SIDING AND REPLACE WITH PAINTED BORAL CLAPBOARD SIDING. REPLACE ALL WOOD TRIM WITH COMPOSITE TRIM WITH PROFILES AND SIZES TO MATCH EXISTING. ALTERNATE #4 - REMOVE/REPLACE ALL EXISTING WINDOWS FOR ALUMINUM-CLAD WINDOWS UP UP CONF. 6-8 OFFICE 01 KITCHEN / BREAK RESTROOM HUDDLE 01 (2) STAIR COAT OFFICE 03 OFFICE 04 JAN. COPY BOOTHHUDDLE 02 (2) LU/LA LIFT STOR. OFFICE 06 FRONT DESK OFFICE 07 OFFICE 08 OFFICE 09 OFFICE 02 OFFICE 05 OFFICE 10 OFFICE 11 OFFICE 12 1 HOUR SHAFT WALL CONSTRUCTION DF NEW LU/LA LIFT NEW SINGLE EXIT DOOR AND SIDELITE RESTROOM CTCT NEW METAL HANDRAIL WITH EPOXY PAINT DOOR TO BE PAINTED NEW METAL HANDRAIL WITH EPOXY PAINT CPT CPT CPT CPT CPT CPT CPT CPT CPTCPTCPT CPT CPT LARGE CONF. CPT CPT CPT CPT OPEN OFFICE CPT SURFACE APPLIED WALK-OFF MAT 6'-0" BYPASS DOOR WITH HEAVY DUTY HEAD TRACK EXISTING BRICK WALKWAY EXISTING WOOD WALKWAY HEAVY DUTY SHELVING 4" FURRED PARTITION CPT NEW WOOD STAIRS TO ATTIC, UNFINISHED SOUTHERN YELLOW PINE CPT LVP LVP SC CORRIDOR CORRIDOR CPT CPT NEW POST WITH TRIM TYP. NEW POST WOOD BASE CABINETS WITH SOLID SURFACE COUNTER AT RECEPTION BUILT IN SOLID SURFACE COUNTER WITH APRON 5'-6" WOOD BASE AND WALL CABINETS 5'-6" WOOD BASE AND WALL CABINETS NEW HIGH-LOW DRINKING FOUNTAIN GWB SOFFIT ABOVE GWB SOFFIT ABOVE CLOSET LVP LVP STOR. LVP NEW SINK NEW SINK BUILT IN SOLID SURFACE COUNTER WITH APRON GWB SOFFIT ABOVE SOUND GASKET AT THIS DOOR SOUND GASKET AT THIS DOOR SOUND GASKET AT THIS DOOR 6"x6" POST 3"x3" POST A-202 4 A-202 3 A-2021 A-2022 ROUT AND SEAL CRACKED CONCRETE FLOOR FULL WIDTH OF BUILDINGEXISTING ALUMINUM DOORS EXISTING CONCRETE STAIRS DOOR LEGEND EXISTING DOOR - TO REMAIN NEW DOOR - TO BE INSTALLED WALL LEGEND EXISTING WALLS - TO REMAIN NEW WALL - TO BE CONSTRUCTED FINISH LEGEND FLOOR CT 12" x 12" CERAMIC TILE - TO BE INSTALLED LVP 7" x 48" LUXURY VINYL PLANK - TO BE INSTALLED CPT 24" x 24" CARPET TILE - TO BE INSTALLED SC SEALED CONCRETE - TO BE INSTALLED 150 LONGWATER DRNORWELL, MA 0206143 HARVARD ST WORCESTER, MA 01609781.871.9804habeebarch.comA R C H I T E C T SH A B E E B& A S S O C I A T E SSCALE: PROJECT NO: DATE: DRAWN BY: CHECKED BY:PLOTTED ON:43 2 1 12 3 4 B C AThis Border is intended for a 22" x 34" sheet. If printed sheet size differs, refer to graphic bar scales only.AS NOTED © Copyright 2024 Habeeb & Associates Architects7/16/2026 1:13:50 PMA-111 FIRST FLOOR PLAN - NEW WORK 2429.01 07/16/26 NSA SB 1330 PHINNEY'S LANEHYANNIS, MA 02601CAPE COD COMMISSIONOFFICE RENOVATION02'4'8' SCALE: 3/16" = 1'-0" 1 FIRST FLOOR - NEW WORK GENERAL NOTES: - ALL NEW INTERIOR WALLS TO RUN TIGHT TO UNDERSIDE OF NEW GWB CEILING - REPLACE 30% OF ATTIC INSULATION TO MATCH EXISTING - REPLACE DAMAGED OR MISSING VAPOR BARRIER AT BOTTOM OF INSULATION AND ATTIC REVISIONS Δ MM-DD-YYYY DESCRIPTION TRUE NORTH BASE BID FOR EXTERIOR BUILDING WORK - NEW SHINGLE ROOFING. SEE ROOF PLAN - NEW 1x8 COMPOSITE FASCIA - PATCH, REPAIR, PREP AND PAINT ALL WOOD TRIM SEE PHOTOS A/201 FOR SPECIFIC REPAIRS - POWER WASH VINYL SIDING (APPROX. 2,680 SF) -POWER WASH AND RE-STAIN CEDAR SHINGLES ALTERNATE #1 - PROVIDE GLASS PARTITION/DOOR SYSTEM AT THE SOUTH CORRIDOR AS SHOWN ON SHEET A-121 AND FRAMING MODIFICATIONS AS SHOWN ON THE STRUCTURAL PLANS. ALTERNATE #2 - PROVIDE AN ALL-ELECTRIC HVAC SYSTEM PER MECHANICAL SPECIFICATIONS. ALTERNATE #3 - REMOVE ALL EXTERIOR SIDING AND REPLACE WITH PAINTED BORAL CLAPBOARD SIDING. REPLACE ALL WOOD TRIM WITH COMPOSITE TRIM WITH PROFILES AND SIZES TO MATCH EXISTING. ALTERNATE #4 - REMOVE/REPLACE ALL EXISTING WINDOWS FOR ALUMINUM-CLAD WINDOWS 26' - 6 1/2" ±85' - 4" ± TYP. VINYL SIDING BAY TYP. CEDAR SHINGLE BAY WATER TABLE AT VINYL SIDING TYP. CEDAR SHINGLES TO BE RE-STAINED, TYP. WOOD TRIM TO BE REPAIRED, PREPPED AND PAINTED TYP. NEW 30 YR ARCHITECTURAL SHINGLES, TYP. NEW GUTTERS AND DOWNSPOUT, TYP. POWER WASH ALL VINYL SIDING TYP. WINDOW TRIM TO BE REPAINTED TYP. NEW 1x8 COMP. FASCIA, TYP.9 1/2" ±10' - 10" ±NEW METAL HANDRAIL WITH EPOXY PAINT EXISTING ALUMINUM DOORS NEW METAL HANDRAIL WITH EPOXY PAINT NEW SINGLE EXIT DOOR WITH SIDELITE SEE DETAIL 4/A-201 FOR LIMIT OF WORK TO BE PERFORMED IN THIS AREA SEE DETAIL 5/A-201 FOR LIMIT OF WORK TO BE PERFORMED IN THIS AREA DOOR TO BE REPAINTED NEW EPOXY COATED HANDRAILS 150 LONGWATER DRNORWELL, MA 0206143 HARVARD ST WORCESTER, MA 01609781.871.9804habeebarch.comA R C H I T E C T SH A B E E B& A S S O C I A T E SSCALE: PROJECT NO: DATE: DRAWN BY: CHECKED BY:PLOTTED ON:43 2 1 12 3 4 B C AThis Border is intended for a 22" x 34" sheet. If printed sheet size differs, refer to graphic bar scales only.AS NOTED © Copyright 2024 Habeeb & Associates Architects7/16/2026 1:13:57 PMA-202 EXTERIOR BUILDING ELEVATION 2429.01 07/16/26 NSA SB 1330 PHINNEY'S LANEHYANNIS, MA 02601CAPE COD COMMISSIONOFFICE RENOVATION02'4'8' SCALE: 3/16" = 1'-0" 4 PLAN NORTH EXTERIOR ELEVATION - NEW WORK 02'4'8' SCALE: 3/16" = 1'-0" 3 PLAN SOUTH EXTERIOR ELEVATION - NEW WORK 02'4'8' SCALE: 3/16" = 1'-0" 1 PLAN EAST EXTERIOR ELEVATION - NEW WORK 02'4'8' SCALE: 3/16" = 1'-0" 2 PLAN WEST EXTERIOR ELEVATION - NEW WORK REVISIONS Δ MM-DD-YYYY DESCRIPTION GENERAL NOTES: BASE BID FOR EXTERIOR BUILDING WORK - NEW SHINGLE ROOFING. SEE ROOF PLAN - NEW 1x8 COMPOSITE FASCIA - PATCH, REPAIR, PREP AND PAINT ALL WOOD TRIM SEE PHOTOS A/201 FOR SPECIFIC REPAIRS - POWER WASH VINYL SIDING (APPROX. 2,680 SF) -POWER WASH AND RE-STAIN CEDAR SHINGLES ALTERNATE #1 - PROVIDE GLASS PARTITION/DOOR SYSTEM AT THE SOUTH CORRIDOR AS SHOWN ON SHEET A-121 AND FRAMING MODIFICATIONS AS SHOWN ON THE STRUCTURAL PLANS. ALTERNATE #2 - PROVIDE AN ALL-ELECTRIC HVAC SYSTEM PER MECHANICAL SPECIFICATIONS. ALTERNATE #3 - REMOVE ALL EXTERIOR SIDING AND REPLACE WITH PAINTED BORAL CLAPBOARD SIDING. REPLACE ALL WOOD TRIM WITH COMPOSITE TRIM WITH PROFILES AND SIZES TO MATCH EXISTING. ALTERNATE #4 - REMOVE/REPLACE ALL EXISTING WINDOWS FOR ALUMINUM-CLAD WINDOWS