Loading...
HomeMy WebLinkAboutCOA 149 Millwayfor Committee use only By a vote of Conditions of Approval This Certificate is hereby APPROVED DENIED Aye Nay Abstain Date __________________________ New Build Addition Alteration Residential Type of Building House Garage Barn Shed Other Project Roof Windo ws/Doors Siding/Painting Solar Other Landscape Feature Fence Wall Flag Pole Pool Other New Sign Replace Sign Repaint Sign Town of Barnstable Old King's Highway Historic District Committee 367 Main Street, Hyannis, Massachusetts 02601 Telephone: (508) 862-4787 Email: erica.brown@town.barnstable.ma.us APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made, with one (1) complete, colored set, for the issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts and Resolves of Massachusetts, 1973, for proposed work as described below and on plans, drawings, or photographs accompanying this application for: Date Date Built: Map & Parcel Property Ow ner Phone Street address Email Village Mailing address Signature Agent/Contractor Phone Agent Address Email Agent Signature If approved, the Certificate of Appropriateness expires one year from the stamped approval date or upon the expiration of a Building Permit, w hichever date shall be later. A one year ex tension may be requested, in w riting, to the Old King’s Highw ay Administrative Assistant at 367 M ain Street, Hyannis, M A 02601. This request must be received prior to the date of expiration. There is a 10 day appeal period plus a four day waiting period for all applications after w hich time your approval paperw ork w ill be availabl e for pickup and building per mit sign-off. All applications are subject to meeting any applicable building code requirements. Check all categories that apply Building Construction Commercial Sign Other _ Description of Proposed Work 10 July 2026 1790, 1860s, 1980 Map 300, Lot 24 Kenneth Morton 149 Millway Barnstable PO Box 197 Barnstable, MA 20630 Gregory Milne for 41° North Architecture 617-669-7111 PO Box 111 Vineyard Haven, MA 02568 gmilne.arch@gmail.com Small, two-story addition to single family home, with small porch at rear. Expanded space will include a roofdeck accessed from the existing third floor. Every attempt will be made to make a historically appropriate and modest addition. See attached authorization letter CERTIFICATE OF APPROPRIATENESS – SPEC SHEET CHIMNEY Material Color ROOF Make & style Color Roof Pitch (s) – (7/12 minimum) (specify on plans for new building & major additions) GUTTER T ype/Material Color WINDOWS, DOORS, TRIM, SHUTTERS, SKYLIGHTS Window/Door Trim material Wood Other specify Size of cornerboards Size of casings (1X4 min) Color Rakes 1st member 2nd Member Depth of overhang Windows: Make/Model Material Color Window Grills Divided Light Exterior Glued Grills Grills Between Glass Removable Interior Grills No Grills Grill Pattern Doors: Style & Make Material Color Garage doors: Style Size of opening Material Color Shutters: Type & Style Material Color Skylights: Type Make & Model Material Size Color SIDING Type Clapboard Shingle Other Material Red Cedar White Cedar Other Paint Color FOUNDATION T ype (max 12’ exposed) DECK Material Color SIGNS Size Materials Color FENCE T ype Color Material Length RETAING WALL Description LIGHTING Type and location (free standing affixed to structure, illuminated) N/A flat/pitched with roof deck roofing not visible Painted wood to match existing Match existing Match existing Match existing Trim build-up Marvin "Ultimate" Clad/wood Match existing 6/6 Marvin "Ultimate"Clad/wood Match existing N/A Match existing Painted wood Match Existing N/A Poured concrete, brick veneer to match existing Weathered rot-resistant wood N/A N/A N/A All exterior lighting (1) wall sconce at rear on covered porch, will be historically appropriate, though not visible from the street Weather to gray CHECKLIST – CERTIFICATE OF APPROPRIATENESS Please complete the Checklist that is applicable to your project. Submit electronic complete colored set, unless otherwise noted FEES Filing Fee according to fee schedule, please make checks payable to the Town of Barnstable Legal Ad fee, will be billed, made payable to the Town of Barnstable First Class Postage Sta mps for abutter notification. Please contact Barnstable Old King’s Highway Office for correct count ALTERATIONS (new paint color, change of siding material, roofing, windows, doors, shutters, etc) Application for Certificate of Appropriateness Spec Sheet, brochures and color samples Plans of building elevatio ns/photographs, ONLY if there is a change to the location and size of the window (s) or Door (s). MINOR ADDITIONS (decks, enclosing a porch, sheds (over 120 sqft) Application for Certificate of Appropriateness, Spec Sheet, brochures and color samples Site Plan, ONLY if there are changes to the footprint (see site plan criteria below) A site plan drawn on a mortgage survey plan or GIS map may be used for minor additions, UNLESS the porch, deck, pool, or Shed etc. is close to lot lines, zoning setback lines, or other buildings, in which case a certified site plan must be submitted Photographs of all building elevation affected by any proposed alterations Plans 1 copy of the plan(s) at reduced scale to fit 8.5x11 or 11x17 paper or 1 electronic complete colored set Company brochure of manufacturers shed or to-scale sketch or affected structure or building elevations ASSESSORY STRUCTURES, NEW/ALTERED (fences, new stonewalls, changes to retaining walls, pools etc) Application for Certificate of Appropriateness Spec Sheet, brochures &/or diagram Site Plan (see site plan criteria below) Photographs of any existing structure that will be affected by the change SIGNS (complete sign supplement) Rendering of the proposed sign, showing graphics, dimensions, design and height of post, color, and materials Site Plan on GIS map or mortgage survey, or photograp hs, or to-scale sketch of building elevation sho wing location of Proposed sign; and any tree to be removed near a freestanding sign (see below for site plan criteria) SOLAR PANELS (complete solar panel supplement) Drawing of locations of panels on house showing roof and panel dimensions Site Plan showing location of building on property (see site plan criteria below) SITE PLAN CRITERIA Name of applicant, street location, map and parcel Name of architect, engineer, or surveyor; original stamp & signature; date of plan & revision dates North arro w, written and drawn to scale Changes to existing grades shown with one -foot contours Proposed & existing footprint of building and/or structures, and distance to lot lines Proposed driveway location Proposed limits of clearing for building (s), assessor structure (s), driveway and septic system Retaining walls or accessory structures (e.g. pool, tennis court, cabana, barn, garage, etc) NEW BUILDINGS, ADDITION, OR COMMERICAL BUILDING CHECKLIST – CERTIFICATE OF APPROPRIATENESS Submit electronic complete colored set, unless otherwise noted Application for Certificate of Appropriateness Spec Sheet, brochures or diagram Site Plan Name of applicant, street location, map and parcel Name of architect, engineer, or surveyor; original stamp & signature; date of plan & revision dates North arrow, written and drawn to scale Changes to existing grades shown with one-foot contours Proposed & existing footprint of building and/or structures, and distance to lot lines Proposed driveway location Proposed limits of clearing for building (s), assessor structure (s), driveway and septic system Retaining walls or accessory structures (e.g. pool, tennis court, cabana, barn, garage, etc) Building Elevations Plans at scale of ¼’ = 1 foot; a written drawn scale Plans at a reduced scale to fit 8.5”x11 or 11x17 paper Name of applicant, street location, map and parcel Name of Building Designer, or architect; original signature of plan preparer and stamp; plan date, and all revision dates. *All new house or commercial building plans must have an original signature and stamp, if any, by a registered Architect, member of AIBD, or a licensed Massachusetts Home Improvement Contractor, unless this requirement is waived by the Old King’s Highway Historic District Committee. A written and bar drawn scale Elevations of all (affected) sides of the building, with dimensions including height from the natural grade adjacent to the Building to the top of the ridge; location and elevation of finished grade, roof pitch (s) dormer setbacks; trim style, windo w And door styles. Changes to existing building must be clouded on drawings. Window schedule on plans Landscape Plan (drawn on a certified perimeter plan containing the following) Name of applicant, street address, assessor’s map and parcel number Name, address, and telephone number of the plan preparer, pl an date, & date of revisions The location of existing and proposed buildings and structures, and lot lines Natural features of site (i.e. rock outcroppings, streams, wetlands, etc) Existing buffer areas to remain Location and species of trees and plants Driveway, parking areas, walkways, and patios, indicating materials to be used Existing stone walls, and proposed walls including retaining walls for slope retention or septic systems For removal of stone walls, you must file a demolition application All proposed exterior lighting and signs Sketch or Photos of adjacent properties A sketch (s) to scale or photographs of nearby adjacent buildings, where present, along both sides of the street frontage, Showing the proposed new house or commercial building in scale and in relationship to the existing buildings. Please discuss with staff if you do not think this is relevant to your application. Photographs of all sides of existing buildings to remain or being added to Existing building, foot print Building 1 (sq. ft.) Building 2 (sq. ft.) Exiting building, gross floor area, including area of finished basement Building 1 (sq. ft.) Building 2 (sq. ft.) New Building or addition, foot print Building 1 (sq. ft.) Building 2 (sq. ft.) New Building or addition, gross floor area, including area of finished basement (sq. ft.) Plan preparer, signature and date 2,025 sq ft 2,888 sq ft 280 sq ft, 350 sq ft with Porch Building 1 (sq. ft.) 644 sq ft , 700 sq ft with Porch Building 2 (Building Drawings) N/A N/A N/A N/A N/A N/A 4 August 2026 SOLAR PANEL SUPPLEMENT STRUCTURE ONE STRUCTURE TYPE Ho me Garage Barn ELEVATION PLACEM ENT North ROOF M EASUREM ENTS South East West Length SOLAR PANEL M EASUREM ENTS Height Pitch Length SOLAR PANEL TYPE & FINISH Depth Width Color Finish (matte or glossy) STRUCTURE TWO STRUCTURE TYPE Ho me Garage Barn ELEVATION PLACEM ENT North ROOF M EASUREM ENTS South East West Length SOLAR PANEL M EASUREM ENTS Height Pitch Length SOLAR PANEL TYPE & FINISH Depth Width T ype Roof Mounted Ground Mounted Canopy/Carport System Color Finish (matte or glossy) Solar Co mpany Phone Solar representative Print Name Signature Date SIGN SUPPLEMENT PROJECT TYPE New Minor Change to Existing Sign Replace Existing Color Replace Existing Sign with New MOUNTING TYPE Post Mount Post Mount Installation Type Surface Installation Direct Burial Installation Wall/Surface Mount Mounting type Elevation affixed to ASTHETICS Size Material Lettering (style) Color Post/Mount Material Color Height to Crossbar Single Faced Double Faced LIGHTING Will the sign be lit Yes No T ype of Lighting Placement of Lighting ADDITIONAL INFORM ATION 149 Millway - Map 300, Lot 24 Existing Elevations 4 August 2026 STREET ELEVATION (EAST) - NO CHANGE TO HISTORIC YARD SIDE ELEVATION (NORTH) - ONLY SIDE TO BE AFFECTED WEST FACING ELEVATION - NOT AFFECTED SOUTH FACING ELEVATIONS - NOT AFFECTED SITE PLAN - GARvEY RESIDENCE 149 MILL WA , BAR NSTABLE , MASS . AsAKDor(Eo BoG 7o . 1MAP43Q0iLOT.4 TRACED FROM PLAN BY ELDREDGE ENGINEERING .-CO./ INC, 7. 0 d P CG. ENGINEERS AND SURV EYORS 36• cTiu 3`. . 4. 7 i.2 MA IN - S T. i-i.YANNISf MASS. N O. 78IoI - DEC. 4- U 78 k-__ D SCALE : I LNCH = 20 FEET o. E il'C. s ' N 1 x/ /0, ,, __, . ??1,01'. r....1,E_YIA 97 of 1, ci9 3 Li 1- a ct 1 x Z K n 14 t, ci - I 1 19. E e yZ S 2 2 0 3 4 3 D ' \V L-- S 5 3° .3:, -.'3 U „ W AI lZ = b30.7 C, y ko MILL W AY 3'-9" 14'5'20' PROPOSED REAR PORCH PROPOSED ADDITION, IN SETBACK, NOT INCREASING NON-CONFORMITY EXISTING TO REMAI N A S I S PROPERTY LINE PROPERTY LINE SETBACK NOTES: - DISRUPTION TO GRADE IS WITHIN ESTABLISHED LAWN, ALL EXISTING PLANTINGS REMOVED, HEELED IN, AND REPLACED AT PROJECT COMPLETION. - GRADE IS FLAT, NO CHANGE TO CONTOURS - DISCREPANCY IN SITE PLANS, TOWN ASSESSOR SHOWS WORST CASE SCENARIO AND IS DEPICTED HERE - LIMIT OF CLEARING IS ONLY FOR FOUNDATION EXCAVATION (+/- 4' OVERDIG)9' PROPOSED DESIGN FOR MORTON'S MORTON                  1" = 20'-0" 149 MILLWAY, BARNSTABLE, MA 4 AUG 2026 THE ORIGINAL SITE PLAN INFO IS NOTED ABOVE, THE PROPOSED ADDITION AND RELATED INFO HAVE BEEN ADDED BY 41° NORTH ARCHITECTURE KEN MORTON - 149 MILLWAY - MAP 300, LOT 24 41° NORTH ARCHITECTURE, LLC AMENDED EXISTING SITE PLAN 4 AUG 2026 DW REF STAIR HALL A A AA2 1 N NOTSCANNED 4'-1"9'-4"6'-7" 5'20'4'3'-7"6'-4 9/16"4'-1/2"PARLORDINING PANTRY KITCHEN EATING SITTING ROOM DECK BEDROOM BATH PORCH DRESSING/ SITTING UP DN DN UP DN DN EXISTING TO REMAIN14'MORTON: EXTERIOR DOOR AND WINDOW SCHEDULE 3-Aug-2026 WINDOWS ID QTY LOCATION MFR.MODEL UNIT (W)UNIT (H)EGRESS TEMPER HARDWARE SCREENS NOTES A 3 BEDROOM MARVIN UWDH 2824 33 3/8 57 YES NO YES FIXED OVER FIXED SEE ELEVATIONS A2 3 BATHS MARVIN UWDH 2824 33 3/8 57 NO YES YES TEMPERED AT BATH B 5 BATH, DEN MARVIN UWDH 2820 29 1/2 61 NO NO YES AWNING OVER FIXED Total 11 EXTERIOR DOORS ID QTY LOCATION MFR.MODEL UNIT (W)UNIT (H)EGRESS TEMPER HARDWARE SCREEN DOOR NOTES 1 1 PORCH SIMPSON 77982 "NANTUCKET"30 78 YES YES YES INSWING: RH, 9-LIGHT, SAPELE, PRIMED AND PAINTED 2 1 ATTIC SIMPSON 77982 "NANTUCKET"36 80 YES YES YES OUTSWING: LH, 9-LIGHT, SAPELE, PRIMED AND PAINTED Total:2 FRAME SIZE SCALE: 1/8" = 1'-0"1 PROPOSED FIRST FLOOR 0 4'8'16' PROPOSED DESIGN FOR MORTON'S MORTON                  1/8" = 1'-0" 149 MILLWAY, BARNSTABLE, MA 4 AUG 2026 KEN MORTON - 149 MILLWAY - MAP 300, LOT 24 41° NORTH ARCHITECTURE, LLC - GREGORY MILNE, ARCHITECT 4 AUG 2026 A2 A2 BBB B B 4'-0"25'-0" 2'-9"6'-4"9'-4"6'-7"3'-6 3/4"6'-4 3/4"4'-0 1/2"14'-0"EXISTING TO REMAIN14'-0"3'-7"6'-4 1/2"4'-0 1/2"STAIR HALLBOOKS HALL BEDROOM SITTING BATH DN UP DN CLOS. STUDY LIINENMORTON: EXTERIOR DOOR AND WINDOW SCHEDULE 3-Aug-2026 WINDOWS ID QTY LOCATION MFR.MODEL UNIT (W)UNIT (H)EGRESS TEMPER HARDWARE SCREENS NOTES A 3 BEDROOM MARVIN UWDH 2824 33 3/8 57 YES NO YES FIXED OVER FIXED SEE ELEVATIONS A2 3 BATHS MARVIN UWDH 2824 33 3/8 57 NO YES YES TEMPERED AT BATH B 5 BATH, DEN MARVIN UWDH 2820 29 1/2 61 NO NO YES AWNING OVER FIXED Total 11 EXTERIOR DOORS ID QTY LOCATION MFR.MODEL UNIT (W)UNIT (H)EGRESS TEMPER HARDWARE SCREEN DOOR NOTES 1 1 PORCH SIMPSON 77982 "NANTUCKET"30 78 YES YES YES INSWING: RH, 9-LIGHT, SAPELE, PRIMED AND PAINTED 2 1 ATTIC SIMPSON 77982 "NANTUCKET"36 80 YES YES YES OUTSWING: LH, 9-LIGHT, SAPELE, PRIMED AND PAINTED Total:2 FRAME SIZE SCALE: 1/8" = 1'-0"1 PROPOSED SECOND FLOOR 0 4'8'16' PROPOSED DESIGN FOR MORTON'S MORTON                  1/8" = 1'-0" 149 MILLWAY, BARNSTABLE, MA 4 AUG 2026 KEN MORTON - 149 MILLWAY - MAP 300, LOT 24 41° NORTH ARCHITECTURE, LLC - GREGORY MILNE, ARCHITECT 4 AUG 2026 2 BEDROOM LOUNGE / STUDIO DECK DN 16'-11"+/-13'-5"+/-MORTON: EXTERIOR DOOR AND WINDOW SCHEDULE 3-Aug-2026 WINDOWS ID QTY LOCATION MFR.MODEL UNIT (W)UNIT (H)EGRESS TEMPER HARDWARE SCREENS NOTES A 3 BEDROOM MARVIN UWDH 2824 33 3/8 57 YES NO YES FIXED OVER FIXED SEE ELEVATIONS A2 3 BATHS MARVIN UWDH 2824 33 3/8 57 NO YES YES TEMPERED AT BATH B 5 BATH, DEN MARVIN UWDH 2820 29 1/2 61 NO NO YES AWNING OVER FIXED Total 11 EXTERIOR DOORS ID QTY LOCATION MFR.MODEL UNIT (W)UNIT (H)EGRESS TEMPER HARDWARE SCREEN DOOR NOTES 1 1 PORCH SIMPSON 77982 "NANTUCKET"30 78 YES YES YES INSWING: RH, 9-LIGHT, SAPELE, PRIMED AND PAINTED 2 1 ATTIC SIMPSON 77982 "NANTUCKET"36 80 YES YES YES OUTSWING: LH, 9-LIGHT, SAPELE, PRIMED AND PAINTED Total:2 FRAME SIZE SCALE: 1/8" = 1'-0"1 PROPOSED ATTIC FLOOR 0 4'8'16' NEW DECK BALUSTRADE TO MEET BUILDING CODES ROOFING MATERIAL NOT VISIBLE FROM PUBLIC WAY DOOR TO REPLACE EXISTING WINDOW PROPOSED DESIGN FOR MORTON'S MORTON                  1/8" = 1'-0" 149 MILLWAY, BARNSTABLE, MA 4 AUG 2026 KEN MORTON - 149 MILLWAY - MAP 300, LOT 24 41° NORTH ARCHITECTURE, LLC - GREGORY MILNE, ARCHITECT 4 AUG 2026 18'-4" +/-3'-4"+/-A A2 B B B 2 18'-4 1/16"+/-3'-4 1/4"+/-AA A2 A2 SCALE: 1/8" = 1'-0"1 NORTH ELEVATION 0 4'8'16' SCALE: 1/8" = 1'-0"2 EAST ELEVATION 0 4'8'16' ALL EXTERIOR MATERIALS TO MATCH EXISTING IN DIMENSIONS, TYPE, AND FINISH NEW DECK BALUSTRADE TO MEET BUILDING CODES ALL EXTERIOR MATERIALS TO MATCH EXISTING IN DIMENSIONS, TYPE, AND FINISH NEW DECK BALUSTRADE TO MEET BUILDING CODES PROPOSED DESIGN FOR MORTON'S MORTON                  1/8" = 1'-0" 149 MILLWAY, BARNSTABLE, MA 4 AUG 2026 KEN MORTON - 149 MILLWAY - MAP 300, LOT 24 41° NORTH ARCHITECTURE, LLC - GREGORY MILNE, ARCHITECT 4 AUG 2026 1 B B SCALE: 1/8" = 1'-0"1 SOUTH ELEVATION 0 4'8'16' SCALE: 1/8" = 1'-0"2 WEST ELEVATION 0 4'8'16' SOUTH ELEVATION UNAFFECTED SECTION THROUGH EXISTING KITCHEN PROPOSED DESIGN FOR MORTON'S MORTON                  1/8" = 1'-0" 149 MILLWAY, BARNSTABLE, MA 4 AUG 2026 KEN MORTON - 149 MILLWAY - MAP 300, LOT 24 41° NORTH ARCHITECTURE, LLC - GREGORY MILNE, ARCHITECT 4 AUG 2026 File: Barnstable House Print Date: 8/6/26DRAFT NOT FOR CONSTRUCTION P.O. BOX 111 VINEYARD HAVEN, MA 02568 C. 617.669.7111 Sheet: A1011ST FLOOR PLANMORTON'S MORTON149 MILLWAY BARNSTABLE MADate: 8/6/26 Drawn by: Scale: As NotedEXISTING CONDITIONS3/20/2026DRAWING SET TYPE AND ISSUE DATE:This drawing should not be used for construction unless noted as such. DW REF STAIR HALL A A AA2 1 N3 A202 1 A201 2 A201 1 A202 2 A202 2 A301 2 A301 1 A301 1 A301 NOTSCANNED 4'-1"9'-4"6'-7" 5'20'4'3'-7"6'-4 9/16"4'-1/2"PARLORDINING PANTRY KITCHEN EATING SITTING ROOM DECK BEDROOM BATH PORCH DRESSING/ SITTING UP DN DN UP DN DN PROJECT NORTHEXISTING TO REMAIN14'GENERAL NOTES LEGEND EXISTING CONSTRUCTION/ELEMENTS NEW CONSTRUCTION/ELEMENTS • ALL CONFLICTS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PERFORMING WORK. • THE DIMENSIONS ON THIS SHEET ARE TO FACE OF FRAMING AND/OR MASONRY, AND CENTERLINE OF COLUMN AND/OR BEAM, UNLESS OTHERWISE NOTED. • DO NOT SCALE THE DRAWINGS. IF A SPECIFIC DIMENSION IS NOT GIVEN, CONTACT THE ARCHITECT FOR CLARIFICATION. • INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS. • ALL FURNITURE AND TELEVISIONS TO BE PROVIDED BY OWNER UNLESS NOTED OTHERWISE. SCALE: 1/4" = 1'-0"2 FIRST FLOOR PLAN 0 2'4'8' File: Barnstable House Print Date: 8/6/26DRAFT NOT FOR CONSTRUCTION P.O. BOX 111 VINEYARD HAVEN, MA 02568 C. 617.669.7111 Sheet: A1022ND FLOOR PLANMORTON'S MORTON149 MILLWAY BARNSTABLE MADate: 8/6/26 Drawn by: Scale: As NotedEXISTING CONDITIONS3/20/2026DRAWING SET TYPE AND ISSUE DATE:This drawing should not be used for construction unless noted as such. A2 A2 BBB B B N3 A202 1 A201 2 A201 1 A202 2 A202 2 A301 2 A301 1 A301 1 A301 4'-0"25'-0" 2'-9"6'-4"9'-4"6'-7"3'-6 3/4"6'-4 3/4"4'-0 1/2"14'-0"EXISTING TO REMAIN14'-0"3'-7"6'-4 1/2"4'-0 1/2"STAIR HALL BOOKS HALL BEDROOM SITTING BATH DN UP DN CLOS. STUDY LIINENPROJECT NORTHGENERAL NOTES LEGEND EXISTING CONSTRUCTION/ELEMENTS NEW CONSTRUCTION/ELEMENTS • ALL CONFLICTS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PERFORMING WORK. • THE DIMENSIONS ON THIS SHEET ARE TO FACE OF FRAMING AND/OR MASONRY, AND CENTERLINE OF COLUMN AND/OR BEAM, UNLESS OTHERWISE NOTED. • DO NOT SCALE THE DRAWINGS. IF A SPECIFIC DIMENSION IS NOT GIVEN, CONTACT THE ARCHITECT FOR CLARIFICATION. • INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS. • ALL FURNITURE AND TELEVISIONS TO BE PROVIDED BY OWNER UNLESS NOTED OTHERWISE. SCALE: 1/4" = 1'-0"1 SECOND FLOOR PLAN 0 2'4'8' File: Barnstable House Print Date: 8/6/26DRAFT NOT FOR CONSTRUCTION P.O. BOX 111 VINEYARD HAVEN, MA 02568 C. 617.669.7111 Sheet: A103ATTIC FLOOR PLANMORTON'S MORTON149 MILLWAY BARNSTABLE MADate: 8/6/26 Drawn by: Scale: As NotedEXISTING CONDITIONS3/20/2026DRAWING SET TYPE AND ISSUE DATE:This drawing should not be used for construction unless noted as such. 2 N3 A202 1 A201 2 A201 1 A202 2 A202 2 A301 2 A301 1 A301 1 A301 BEDROOM LOUNGE / STUDIO DECK DN PROJECT NORTH16'-11"+/-13'-5"+/-SCALE: 1/4" = 1'-0"1 ATTIC FLOOR PLAN 0 2'4'8' File: Barnstable House Print Date: 8/6/26DRAFT NOT FOR CONSTRUCTION P.O. BOX 111 VINEYARD HAVEN, MA 02568 C. 617.669.7111 Sheet: A201ELEVATIONSMORTON'S MORTON149 MILLWAY BARNSTABLE MADate: 8/6/26 Drawn by: Scale: As NotedEXISTING CONDITIONS3/20/2026DRAWING SET TYPE AND ISSUE DATE:This drawing should not be used for construction unless noted as such. FIRST FLOOR ±0" SECOND FLOOR +8'-11" ATTIC FLOOR +16'-10"18'-4 1/16"+/-3'-4 1/4"+/-AA A2 A2 GENERAL NOTES • ALL CONFLICTS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PERFORMING WORK. • THE DIMENSIONS ON THIS SHEET ARE TO FACE OF FRAMING AND/OR MASONRY, AND CENTERLINE OF COLUMN AND/OR BEAM, UNLESS OTHERWISE NOTED. • DO NOT SCALE THE DRAWINGS. IF A SPECIFIC DIMENSION IS NOT GIVEN, CONTACT THE ARCHITECT FOR CLARIFICATION. • INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS. EXISTING CONSTRUCTION/ELEMENTS NEW CONSTRUCTION/ELEMENTS FIRST FLOOR ±0" SECOND FLOOR +8'-11" ATTIC FLOOR +16'-10"18'-4 5/16" +/-3'-4 1/4"+/-A A2 B B B 2 SCALE: 1/4" = 1'-0"1 EAST ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"2 NORTH ELEVATION 0 2'4'8' File: Barnstable House Print Date: 8/6/26DRAFT NOT FOR CONSTRUCTION P.O. BOX 111 VINEYARD HAVEN, MA 02568 C. 617.669.7111 Sheet: A202ELEVATIONSMORTON'S MORTON149 MILLWAY BARNSTABLE MADate: 8/6/26 Drawn by: Scale: As NotedEXISTING CONDITIONS3/20/2026DRAWING SET TYPE AND ISSUE DATE:This drawing should not be used for construction unless noted as such. GENERAL NOTES • ALL CONFLICTS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PERFORMING WORK. • THE DIMENSIONS ON THIS SHEET ARE TO FACE OF FRAMING AND/OR MASONRY, AND CENTERLINE OF COLUMN AND/OR BEAM, UNLESS OTHERWISE NOTED. • DO NOT SCALE THE DRAWINGS. IF A SPECIFIC DIMENSION IS NOT GIVEN, CONTACT THE ARCHITECT FOR CLARIFICATION. • INSTALL ALL PRODUCTS PER MANUFACTURER'S RECOMMENDATIONS. EXISTING CONSTRUCTION/ELEMENTS NEW CONSTRUCTION/ELEMENTS 1 B B FIRST FLOOR ±0" SECOND FLOOR +8'-11" ATTIC FLOOR +16'-10" SCALE: 1/4" = 1'-0"1 WEST ELEVATION-PARTIAL 0 2'4'8'SCALE: 1/4" = 1'-0"2 WEST ELEVATION 0 2'4'8' SCALE: 1/4" = 1'-0"3 SOUTH ELEVATION 0 2'4'8' HYANNIS, MA 02601 300022 BARNSTABLE, TOWN OF (LDG) 367 MAIN STREET Property ID: 72 FREEZER ROAD BARNSTABLE, MA 02630 300023001 HICKEY, BRIAN J & KAREN ELIZABETH TRS SEA WINDS FAMILY TRUST Property ID: BARNSTABLE, MA 02630 300023002 RAPP, JAN 107 MILLWAY Property ID: PO BOX 197 BARNSTABLE, MA 02630 300024 MORTON, ELIZABETH G TR ONE HUNDRED FORTY NINE MILL WAY RE TR Property ID: PO BOX 1178 BARNSTABLE , MA 02630 300036 SHUCK, WENDY B TR WENDY B SHUCK TRUST Property ID: 150 MILLWAY BARNSTABLE, MA 02630 300037 MUHLEBACH, GEORGE J TR 150 MILLWAY REALTY TRUST Property ID: PO BOX 553 BARNSTABLE, MA 02630 300038 WEBER, DAVID E & CAROLE C TRS WEBER FAMILY TRUST Property ID: