HomeMy WebLinkAbout0084 ANSEL HOWLAND ROAD - Health J
84 ANSEL HOWLAND RD., CENTERVILLE
bPC 12534 � -
No.21_ 5�3LOR '�sr
i ASTINYi,Yfl
COMMONWEALTH OF MASSACHUSETTS
EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS John Grad
DEPARTMENT OF ENVIRONMENTAL PROTECTION DEP Title V Septic Inspector
ONE WINTER STREET BOSTON MA 02108(617)292-3500 P.O.Box 2119
TeaTicket,Ma.
(508)564-6813
TRUDY COXE
Secretary
ARGEO PAUL CELLUCCI DAVID B.STRUHS
Govemor Commissioner
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION
Property Address: 84 ANSEL HOWLAND RD. CENTERVILLE MAP 172-PAR 232 LOT 32
Name of Owner GEORGE MYERS
Address of Owner: SAME
Date of Inspection: 8l6/99
Name of Inspector:(Please Print)JOHN GRACI } "-
1 am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000) 1b .�
s
Company Name: n/a -9G
Mailing Address: n/a (�
Telephone Number: n/a 1 <-
CERTIFICATION STATEMENT 9
I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is ccurate
and complete as of the time of inspection.The inspection was performed based on my training and experience in the proper fun
maintenance of on-site sewage disposal systems.The system: ar `
X Passes The inpection Is based on criteria defined in Title V
Conditionally Passes code 310 CMR 15.303.My findings are of how the system is
Needs Further Eva ation By the Local Approving Authority performing at the time of the Inspection.My inspection does
Fails not imply any warranty or guarantee of the longgevity of the
septic system and any of its components useful life.
Inspector's Signature: Date:8111/99
The System Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within thirty(30)days of
completing this inspection. f the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner
shall submit the report to the appropriate regional office of the Department of Environmental Protection.The original should be sent to the
system owner and copies sent to the buyer,if applicable,and the approving authority.
NOTES AND COMMENTS
THE SYSTEM PASSES TITLE V INSPECTION. RECOMMEND PUMPING SYSTEM EVERY TWO YEARS TO PROLONG THE SYSTEM'S USEFULL
.LIFE.
revised 9/2198 Page 1 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:816/99
INSPECTION SUMMARY: Check A, B, C, o!D:
A. SYSTEM PASSES:
I have not found any information which indicates that any of the failure conditions described in 310 CMR 15.303 exist.Any failure criteria not evaluated
are indicated below.
COMMENTS:
System passes Title V inspection
B. SYSTEM CONDITIONALLY PASSES:
nLa One or more system components as described in the"Conditional Pass"section need to be replaced or repaired.The system,upon completion of the
replacement or repair,as approved by the Board of Health,will pass.
Indicate yes,no,or not determined(Y,N,or ND).Describe basis of determination in all instances.If"not determined",explain why not.
nLa The septic tank is metal,unless the owner or operator has provided the system inspector with a copy of a Certificate of
Compliance(attached)indicating that the tank was installed within twenty(20)years prior to the date of the inspection;or
the septic tank,whether or not metal,is cracked,structurally unsound,shows substantial infiltration or exfiltration,or tank
failure is imminent.The system will pass inspection if the existing septic tank is replaced with a complying septic tank as
approved by the Board of Health.
n& Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed pipe(s)
or due to a broken,settled or uneven distribution box.The system will pass inspection if(with approval of the Board of Health).
_ broken pipe(s)are replaced
obstruction is removed
distribution box is levelled or replaced
Wa The system required pumping more than four times a year due to broken or obstructed pipe(s).The system will pass
inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
revised 9/2198 Page 2 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:816199
C. FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH:
_ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the public health,safety
and the environment.
1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES IN ACCORDANCE WITH 310 CMR 16.303(1)(b)THAT THE SYSTEM IS
NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT ThE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
_ Cesspool or privy is within 50 feet of surface water
_ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER.IF ANY)DETERMINES THAT THE SYSTEM IS
FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
_ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a
surface water supply.
_ The system has a septic tank and soil absorption system and the SAS is within a Zone I of a public water supply well.
_ The system has a septic tank and soil absorption system and the SAS is within 50 feet of a private water supply well,
_ The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a
private water supply well,unless a well water analysis for coliform bacteria and volatile organic compounds indicates that the
well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less
than 5 ppm,Method used to determine distance nla-(approximation not valid).
3) OTHER
nla
revised 9/2/98 Page 3 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:8/6/99
D. SYSTEM FAILS:
You must indicate either"Yes"or"No"to each of the following:
I have determined that one or more of the following failure conditions exist as described in 310 CMR 15.303.The basis for this determination is
identified below.The Board of Health should be contacted to determine what will be necessary to correct the failure.
Yes No
X Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool.
X Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool.
X Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
X Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow,
X Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).
Number of times pumped Wa.
X Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation.
X Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply.
X Any portion of a cesspool or privy is within a Zone I of a public well.
X Any portion of a cesspool or privy is within 50 feet of a private water supply well,
X Any portion of a cesspool or privy is less-than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality
analysis.If the well has been analyzed to be acceptable,attach copy of well water analysis for coliform bacteria,volatile organic ompounds,
ammonia nitrogen and nitrate nitrogen.
X The liquid level in the SAS is over the invert pipe,is in Hydraulic Failure.
E. LARGE SYSTEM FAILS:
You must indicate either"Yes"or"No"to each of the following:
The following criteria apply to large systems in addition to the criteria above:
The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to public health and
safety and the environment because one or more of the following conditions exist:
Yes No
X the system is within 400 feet of a surface drinking water supply
X the system is within 200 feet of a tributary to a surface drinking water supply
X the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped Zone li of a public
water supply well)
The owner or operator of any such system shall upgrade the system in accordance with 310 CMR 15.30412).Please consult the local regional office of the
Department for further information.
revised 9/2/98 Page 4 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:8/6199
Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following:
Yes No
X Pumping information was provided by the owner,occupant,or Board of Health.
X None of the system components have been pumped for at least two weeks and-the system has been receiving normal flow rates
during that period.Large volumes of water have not been introduced into the system recently or as part of this inspection.
X As built plans have been obtained and examined.Note if they are not available with N/A,
X The facility or dwelling was inspected for signs of sewage back-up.
X The system does not receive non-sanitary or industrial waste flow.
X The site was inspected for signs of breakout,
X All system components,excluding the Soil Absorption System,have been located on the site.
X The septic tank manholes were uncovered,opened,and the interior of the septic tank was inspected for condition of baffles
or tees,material of construction,dimensions,depth of liquid,depth of sludge,depth of scum.The size and location of the Soil Absorption
System on the site has been determined based on:
X Existing information,For example,Plan at B4O,H,
X Determined in the field(if any of the failure criteria related to Part C is at issue,approximation of distance is unacceptable)
[1 5.302(3)(b)]
X The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of
SubSurface Disposal Systems.
revised 9/2/98 Page 5 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C '
SYSTEM INFORMATION
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:8/6/99
FLOW CONDITIONS
RESIDENTIAL
Design flow:-=g.p.d./bedroom
Number of bedrooms(design): 3 Number of bedrooms(actual):A
Total DESIGN flow: 3.3.Q
Number of current residents:2
Garbage grinder(yes or no):NQ
Laundry(separate system)(yes or no): NO If yes,separate inspection required
Laundry system inspected(yes or no):-W
Seasonal use(yes or no):_NQ
Water meter readings,if available(last two year's usage(gpd): Wa
Sump Pump(yes or no): NO
Last date of occupancy: DLa
COMMERCIALIINDUSTRIAL
Type of establishment: DLa
Design flow: Wa gpd(Based on 15.203)
Basis of design flow: DLa
Grease trap present:(yes or no):JLQ
Industrial Waste Holding Tank present:(yes or no): tlQ
Non-sanitary waste discharged to the Title 5 system:(yes or no):tYo
Water meter readings.if available:DLa
Last date of occupancy: DLa
OTHER: (Describe)
DLa
Last date of occupancy: D/A
GENERAL INFORMATION
PUMPING RECORDS and source of information:
nta
System pumped as part of inspection:(yes or no):NQ
If yes,volume pumped DLa_ gallons
Reason for pumping: D/a
TYPE OF SYSTEM
X Septic tankidistribution box/soil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system(yes or no)(if yes.attach previous inspection records,if any)
I/A Technology etc.Attach copy of up to date operation and maintenance contract
Tight Tank Copy of DEP Approval
Other: Wa
APPROXIMATE AGE of all components,date installed(if known)and source of information:
1982 PERMIT 82-62
Sewage odors detected when arriving at the site:(yes or no) IYO
revised 9/2198 Page 6 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232_LOT 32
Owner: GEORGE MYERS
Date of Inspection:816/99
BUILDING SEWER:
(Locate on site plan)
Depth below grade: V 6"
Material of construction:_ cast iron X 40 PVC _ other(explain)
Distance from private water supply well or suction line: TOWN
Diameter: nLa
Comments: (condition of joints,venting,evidence of leakage,etc.)
nLa
SEPTIC TANK: X
(locate on site plan)
Depth below grade: T
Material of construction:X concrete_ metal_ Fiberglass _ Polyethylene _ other(explain)
nLa
If tank is metal,list age Is age confirmed by Certificate of Compliance(Yes/No): NO
nLa
Dimensions: L 8'6"H 5'7"W 4'10"
Sludge depth: E
Distance from top of sludge to bottom of outlet tee or baffle: L
Scum thickness:
Distance from top of scum to top of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle: 17"
How dimensions were determined: MEASURED
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,
etc.)
SEPTIC TANK AND ALL COMPONENTS ARE STRUCTURALLY SOUND_RECOMMEND PUMPING EVERY TWO YEARS,
GREASE TRAP:
(locate on site plan)
Depth below grade:
Material of construction:_concrete_ metal_ Fiberglass _ Polyethylene_other(explain)
nta
Dimensions: n&
Scum thickness: n&
Distance from top of scum to top of outlet tee or baffle:jVa
Distance from bottom of scum to bottom of outlet tee or baffle n&
Date of last pumping: n&
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,evidence of leakage,
etc.)
nLa
revised 9/2/98 Page 7 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:8/6/99
TIGHT OR HOLDING TANK: NQ (Tank must be pumped prior to,or at time of,inspection)
(locate on site plan)
Depth below grade: nA
Material of construction:_ concrete_ metal_ Fiberglass _Polyethylene_ other(explain)
WA
Dimensions: nLa
Capacity: nLa gallons
Design flow: Wa gallons/day
Alarm present: NO
Alarm level:jiLa- Alarm in working order:Yes—No—: NO
Date of previous pumping: Wa
Comments:
(condition of inlet tee,condition of alarm and float switches,etc.)
WA
DISTRIBUTION BOX: _
(locate on site plan)
Depth of liquid level above outlet invert:WA
Comments:
(note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,etc.)
IlLa
PUMP CHAMBER: NQ
(locate on site plan)
Pumps in working order:(Yes or No): NIQ
Alarms in working order(Yes or No): NO
Comments:
(note condition of pump chamber,condition of pumps and appurtenances.etc.)
Wa
revised 9/2/98 Page 8 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR M LOT 32
Owner: GEORGE MYERS
Date of Inspection:816/99
SOIL ABSORPTION SYSTEM(SAS): X
(locate on site plan,if possible;excavation not required,location may be approximated by non-intrusive methods)
If not located,explain:
WA
Type:
leaching pits,number: 1000 GALLON OCTAGON PIT
leaching chambers,number: 1]La
leaching galleries,number: _n/.a
leaching trenches,number,length: n&
leaching fields,number,dimensions: a&
overflow cesspool,number: n&
Alternative system: nLa
Name of Technology: jVA
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.)
THE LEACH PIT IS STRUCTU ALL SOUND AND FUNTIONING PROPERLY THE PIT HAS NOT BEEN MORE THAN 1/2 FULL
CESSPOOLS: _
(locate on site plan)
Number and configuration: nta
Depth-top of liquid to inlet invert: n&
Depth of solids layer: n&
Depth of scum layer. nLa
Dimensions of cesspool: n&
Materials of construction: n&
Indication of groundwater: n(a inflow(cesspool must be pumped as part of inspection)nta
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
nta
PRIVY: _
(locate on site plan)
Materials of construction:n& Dimensions:Wa
Depth of solids: n&
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
nla
revised 9/2/98 Page 9 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:8/6/99
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent reference landmarks or benchmarks
locate all wells within 100'(Locate where public water supply comes into house)
n/a
L
O
AA a�
'31�
gli 3�► b
revised 9/2/98 Page 10 of 11
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 84 ANSEL HOWLAND RD.CENTERVILLE MAP 172-PAR 232 LOT 32
Owner: GEORGE MYERS
Date of Inspection:816199
NRCS Report name: nLa
Soil Type: nLa
Typical depth to groundwater: nLa
USGS Date website visited: nta
Observation Wells checked: NQ
Groundwater depth:Shallow _ Moderate _ Deep _
SITE EXAM _ Slope
_ Surface water
_ Check Cellar
_ Shallow wells
Estimated Depth to Groundwater 12 Feet
Please indicate all the methods used to determine High Groundwater Elevation:
- Obtained from Design Plans on record
_ Observed Site(Abutting property,observation hole,basement sump etc.)
_ Determined from local conditions
_ Checked with local Board of health
_ Checked FEMA Maps
_ Checked pumping records
_ Checked local excavators,installers
X Used USGS Data
Describe how you established the High Groundwater Elevation.(Must be completed)
USGS MAPS AND CHARTS
revised 9/2/98 Page 11 of 11
No..... ..� +'r j� s......S,l�15../
THE COMMONWEALTH OF MASSACHUSETTS �~
BOAR® OF HEALTH
OT.ft+ ................OF....................................... .............................................
Applira#ion for Disposal Marko Tnnitrnrtion Prratit
Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal
System
..• -• • --••••••--.._....-•••••-•-•-•--•-••.........---•-•......---
l Locationddress r Lot
...................... .... ....•••-••---•••-••-•••••-•......._•.............................• ..........
Owner Address
.......................................... ................ ...... ........ ...............................................
Installer Address
dType of Building Size Lot..... .....Sq. feet
UV Dwelling—No. of Bedrooms...____._ Expansion Attic ( ) Garbage Grinder (A**p
----------------------•-_...
Other—Type e of Building No. of persons............................ Showers
G� YP g ----•-•-•-----------•-•-•--- P ( ) - Cafeteria ( )
Q' Other fixtures --------------- ------••---•--- • • .
d -------------•----------•---••--•--•-----............_.._
W Design Flow......-_r'L�_.�3.........................gallons per person per day. Total daily flow...... 3_ .........................gallons.
WSeptic Tank—Liquid capacity/,?._p..gallons Length................ Width................ Diameter................ Depth................ '
x Disposal Trench—No..................... Width.................... Total Length.................... Total leaching area....................sq. ft.
Seepage Pit No..,/40--- ------ Diameter...4&.X48... Depth below inlet.................... Total leaching area..................sq. ft.
Z Other Distribution box ( ) Dosing tank ( )
aPercolation Test Results Performed by.......................................................................... Date........................................
Test Pit No. 1................minutes per inch Depth of Test Pit.................... Depth to ground water--___-_____-_.-_---_,__.
G Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water.........................
-------------------------•------•-•••---•••----......--•------------......------•---.......................................................
•-----
_........
••-
ODescription of Soil........................................................................................................................................................................
x
W
UNature of Repairs or Alterations—Answer when applicable..............................•.___._...._......_....__.._.._._..........._......__.............
-------------------------------------•----------•-------••-•-----------------------•---•--------•-•-•-•----•....•---------...•-------•---•-•••••----------------•-•--•---•-••-•----...................
Agreement:
The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of'T11Z 5 of the State Sanitary Code—The undersigned further agrees not to place the system in
operation until a Certificate of Compliance has been 'ssued by the bb aanddoof health.
L�X- ---...---••-
��ate
Application Approved By........ = ........................ -�4w- ..2+__�-
Date
Application Disapproved for the following reasons:...............•-•---------•--------•-----------------•---------•-------------------...........................
-•------------------•-•••-------•----------•---•--•••------------•---•--•------••--•---•--•--•-------- ---•---••-----•------------------•-------•---------------------•------•----••---------•-------
Date
PermitNo......................................................... Issued.......................................................
THE COMMONWEALTH OF MASSACHUSETTS ;
BOARD OF HEALTH
OF..........................................................................................
Appliration for Uhipati al Works Tnnitrnrtion trntijt
Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal
System at:
................_--......-...................................................................... --•--•------------------•----•---•---•-••----- .........
Location•Address or Lot No.
.................................................................................................. ......_._...__.................._..........-----•----•-•-•-----•--••..............................
Owner Address
...........-•----•----......--•-----••---^_....-•.•--------•-••-•................................ .•----......------------------•............-----------..._....._...................--•---••-•-----
Installer Address
dType of Building Size Lot............................Sq. feet
U Dwelling—No. of Bedrooms............................................Expansion Attic ( ) Garbage Grinder ( )
aOther—Type of Building ............................ No. of persons............................ Showers ( ) — Cafeteria ( )
Pa Other fixtures -----------•-•------------••--•. .
W Design Flow............................................gallons per person per day. Total daily flow............................................gallons.
WSeptic Tank—Liquid capacity............gallons Length................ Width................ Diameter................ Depth................
x Disposal Trench—No..................:.. Width.................... Total Length.................... Total leaching area....................sq. ft.
Seepage Pit No..................... Diameter.................... Depth below inlet........:........... Total leaching area..................sq. ft.
Z Other Distribution box ( ) Dosing tank ( )
Percolation Test Results Performed by.......................................................................... Date........................................
aTest Pit No. 1................minutes per inch Depth of Test Pit.................... Depth to ground water........................
Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................
•--••-------------------- ------•----------...._....-------••--••---•---•-------------------._....----•---•----•------••------------------.._.........------.
0 Description of Soil...........................................................................................................=--•-----•---•--...------------------------------------------
W ---•----------------•---•-----•-•-•--------•----•------•---------•------•--------•------------------------------------------•---------•-----------------------•--------------------------•....----------
UNature of Repairs or Alterations—Answer when applicable...............................................................................................
Agreement:
The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of TITI TITLE 5 of the State Sanitary Code—The undersigned further agrees not to place the system in
operation until a Certificate of Compliance has been issued by the board of health.
Signed.................•-•----•-•-------.......------------------------------------------_._ ..........................
e �
ate
Application Approved BY--------- -- - - .......... --------------
Date Application Disapproved for the following reasons:........................................-----------------------•-----•---------•-------------------------------
-------------------------------------•----•-------------------------------•------------------------------------------.......-•---------------------•------------------•---•------------................
Date
PermitNo.......................................................... Issued.......................................................
Date
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
...........OF....... -: . .......................................
Trdifiratr of ToutpliFanrr � �,,�
THIS IS TO RTIFY That the Individual Sewage Disposal System constructed (�") or Repaired ( )
bY..............: -------- ---------------------------------------------------------------------------------------------------------------------------------------
st
at...............: ..... ......... ...tt..c--- .W, .............................---------
has been installed in accordance with the provisions of TITLE 5 of The State Sanitary Code as described in the
application for Disposal Works Construction Permit No.._- ........... dated..............................._..._..._........
THE ISSUANCE OF TH CER 1FICATE SHALL NOT BE CONST 0 AS GUARANTEE THAT THE
SYSTEM WILL FUNC ON SATI, STORY. ,
DATE.................................. ._ :f�. :....__... Inspector..-•-= --- .............................................................
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
....
« FEE
Dispoii tl Norkg T-Vnni#rndinn rrntit
Permission is ereby granted---- -------- -------------------------------------------•--------------------•---........----•-.......
to Construct Re air ( ) an-individual Sew ge—p-sposal Sys,em
Street
as shown on the application for Disposal Works Construction Permit No.1�_ Dited..............
--- a ....................................
DATE..................................... • ..........•--------------------
FORM 1255 HOBBS & WARREN. INC.. PUBLISHERS '_'.,y.„...
f
LOCATION 232-,�=
E PERMIT NO.
.L-o i �3�- 2 4
VILLAGE
x . ��>�
d f>f!i s
IN.ST-A LLER'S NAME i ADDRESS
B U I L D E R OR OWNER
'S®x 5-3 4# F-AVII,1. F CIA
DA- T E PERMIT ISSUED Z �.��
DAT,+E COMPLIANCE ISSUED. g `'
C•� C F c(S
rya �
QI
uo GAMIZAGS C lZt$.btE4E4Z �`i rC/SEL
: Ddt L�q I`Low a Ito 4-S .
33o G•Pty o►;v�,q,yD 12
.EEFlnc Tu Atc- - -SSO i ISo % • ASj56,Rfl s.• v�� F
U S4C— t 00=� 6At_.
i .Z15P0-S,&.. PIT VSE I000 CMA4-.
I % 'Ux w4 LI- AeSA _ I5,o 4G F.
I I� 5�. ,c 2.S • 3"7S G.P.D. '
3 TOTAL 'VES161J a 42S G D �
t D
t. TbTo L mat t_�f FLow • M , \` r
vMOC-ot.e,Ttov W&TE : w 2MIu'oa Ls%.
7-AV9. �` {
AL'64
itµ ors'
R(CHARDA.
N I>•� 1 Cq D47
BAXTERk ell
v i •j I i;�
Zo
i -'r�-5 I'), Tor Put. a
fA :.�N;VJ 7�►ice � °�v57
wC st'P� '� Itw.•� }
a b I oeo Y1V.
• .1 5
2 / -Sox 514 SEPMC I c
SAND ( -rAwic
1000
Wivi
&IA"✓6L GAL. 53lZ,
FlT
.. .� .11 • v •. .. ' ` 1 ` -. is
WASWILD ti
sTo.I rcI 147a -'.r 5
.JQ�D. /� �o' � �• 't I v
CSZTtr-lam PLOT
LOGATIOt-
fL�4''3II /3 Uo SasLE-
'' 5c1�LC— ` t�,Sv bA'f'� -2
12 ( g- 1
No U'�AT��2 � • �
I CCIZT PN TkAT TO& ou+3DA-nc>4 SNoww. t PLAQ paV-1;►Jca
WC.Q t,ow d4oAArL.YS W ITA TWa SI VlE-Ll (=, LIT32
Ate ScTl�ncK 1"c4�tCEti+ruTS ot= Tµ� ,
-TO w Q Or--; :B4 IZ�kiTA
t2-2 Lg C�►.1T�R1�It..1.3 � tl�l�a�t>�
VATC
RCGISILIZzD 1-Awo ;,uZvaYoeS
TI-�t C�tjAI,J IS L40T ZASGV' Vi-4 AW 05TECVILttz c� MASS. a
11Jsl'LtJMCaJ:i ��Uc_�/l=�( �• TILL UFc:;ITS SI•IGtJt.D tt��--
U l- n r� t�ct I►dl:: Loy- l_I N� G � � A GL G
I•fc>r C.C: -- 1'CCM .+ AUQ SIC:—