Loading...
HomeMy WebLinkAbout0045 BRETWOOD LANE - Health ; 5 Bretwoed Lane Centerville P A = 168 121 r` Ord. NO. 152 1/3 ORA ,�w� ------ 10% v .. r COMMONWEALTH OF MASSACHUSETTS EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS DEPARTMENT OF ENVIRONMENTAL PR TEIVED AUG 2 8 Z003 TOWN OF BARNSTABLE HEALTH DEPT. TITLE 5 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM PART A CERTIFICATION Property Address: 45 Bretwood Lane Centerville, MA 02632 Owner's Name: Lino Crarieri Owner's Address: Date of Inspection: July 28, 2003 Name of Inspector: (Please Print) James:M. Ford Company Name: James M. Ford Mailing Address: P.O. Box 49 Map: 168 Osterville,MA 02655-0049 Parcel. 121 Telephone Number: (508) 862-9400 Lot: 18 CERTIFICATION STATEMENT I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system: ✓ Passes Conditionally Passes Needs Further Evaluation by the Local Approving Authority Fails Inspector's Signature: Date: July 31, 2003 The system inspector shall subl a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving authority. Notes and Comments ""This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. Title 5 Inspection Form 6/15/2000 page 1 , P Pg Page 2 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 45 Bretwood Lane Centerville, AM Owner: Lino Crarieri Date of Inspection: July 28, 2003 Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D A. System Passes: ✓ I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B. System Conditionally Passes: One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass. Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined", please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not)is structurally unsound,exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if (with approval of Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced T ND explain: The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The,system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed ND explain: 2 I Page 3 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 45 Bretwood Lane Centerville, MA Owner: Lino Crarieri Date of Inspection: July 28, 2003 C. Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health,safety or the environment. 1. System will pass unless.Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health,safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh 2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the system is functioning in a manner that protects the public health,safety and environment: _ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone I of a public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. _ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance **This system passes if the well water analysis,performed at a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: 3 Page 4 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 45 Bretwood Lane Centerville, M4 Owner: Lino Crarieri Date of Inspection: July 28, 2003 D. System Failure Criteria applicable to all systems: You must indicate either"yes"or"no"to each of the following for all inspections: Yes No ✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ✓ Liquid depth in cesspool is less than 6"below invert or available volume is less than '/z day flow ✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped— ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation. ✓ Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ✓ Any portion of a cesspool or privy is within a Zone 1 of a public well. ✓ Any portion of a cesspool or privy is within 50 feet of a private water supply well. ✓ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.) No (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E. Large System: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd• You must indicate either`yes"or"no"to each of the following: (The following criteria apply to large systems in addition to the criteria above) Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply _ the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area- IWPA)or a mapped Zone II of a public water supply well If you have answered`yes"to any question in Section E the system is considered a significant threat,or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 4 Page 5 of I 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 45 Bretwood Lane Centerville, MA Owner: Lino Crarieri Date of Inspection: July 28, 2003 Check if the following have been done: You must indicate"yes"or"no"as to each of the following: Yes No ✓ _ Pumping information was provided by the owner,occupant,or Board of Health ✓ Were any of the system components pumped out in the previous two weeks? ✓ Has the system received normal flows in the previous two week period? ✓ Have large volumes of water been introduced to the system recently or as part of this inspection ? ✓ _ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ✓ Was the facility or dwelling inspected for signs of sewage back up? ✓ _ Was the site inspected for signs of break out? ✓ _ Were all system components,excluding the SAS,located on site? ✓ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum ? ✓ _ Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)on the site has been determined based on: Yes No ✓ _ Existing information. For example,a plan at the Board of Health. ✓ _ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(3)(b)]. 5 I Page 6 of I 1 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 45 Bretwood Lane Centerville, MA Owner: Lino Crarieri Date of Inspection: July 28, 2003 FLOW CONDITIONS RESIDENTIAL Number of bedrooms(design): 4 Number of bedrooms(actual): 4 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 440 Number of current residents: 0 Does residence have a garbage grinder(yes or no): No Is laundry on a separate sewage system(yes or no): No [if yes separate inspection required] Laundry system inspected(yes or no): No Seasonal use(yes or no): No Water meter readings, if available(last 2 years usage(gpd)): Unavailable Sump Pump(yes or no): No Last date of occupancy: Weekend use COMMERCIAIJ NDUSTRIAL Type of establishment: Design flow(based on 310 CMR 15.203): gpd Basis of design flow(seats/persons/sgft,etc.): Grease trap present(yes or no): Industrial waste holding tank present(yes or no) Non-sanitary waste discharged to the Title 5 system(yes or no): Water meter readings, if available: Last date of occupancy/use: OTHER(describe): GENERAL INFORMATION Pumping Records Source of information:Pumped 4 years ago-per owner Was system pumped as part of the inspection(yes or no): No If yes, volume pumped: _gallons--How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM ✓ Septic tank,distribution box,soil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no) (if yes,attach previous inspection records, if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight Tank Attach a copy of the DEP approval Other(describe): Approximate age of all components,date installed(if known)and source of information: Jul. 18186-per as built card Were sewage odors detected when arriving at the site(yes or no): No 6 Page 7 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 45 Bretwood Lane Centerville, AM Owner: Lino Crarieri Date of Inspection: July 28, 2003 BUILDING SEWER(locate on site plan) Depth below grade: Materials of construction: _cast iron _40 PVC _other(explain): Distance from private water supply well or suction line: Comments(on condition of joints,venting,evidence of leakage,etc.): SEPTIC TANK: ✓ (locate on site plan) Depth below grade: 16" Material of construction: ✓ concrete _metal _fiberglass _polyethylene _other(explain) If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of certificate) Dimensions: 1000 gal. Sludge depth: 1" Distance from top of sludge to bottom of outlet tee or baffle: 30" Scum thickness: 3" Distance from top of cum to top of outlet tee or baffle: 10" Distance from bottom of scum to bottom of outlet tee or baffle: 10" How were dimensions determined: Measuring stick Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert,evidence of leakage,etc.): Tees were present. The liquid level was even with the outlet invert. There were no signs of leakage. GREASE TRAP: None (locate on site plan) Depth below grade: Material of construction: _concrete _metal _fiberglass _polyethylene _other (explain): Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Comments(on pumping recommendations, inlet and outlet tee or baffle condition,structural integrity, liquid levels as related to outlet invert,evidence of leakage,etc.): 7 Page 8 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 45 Bretwood Lane Centerville, AM , Owner: Lino Crarieri Date of Inspection: July 28, 2003 TIGHT or HOLDING TANK: None (tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: _concrete _metal _fiberglass _polyethylene _other(explain): Dimensions: Capacity: gallons Design Flow: gallons/day Alarm present(yes or no): Alarm level: Alarm in working order(yes or no): Date of last pumping: Comments(condition of alarm and float switches,etc.): DISTRIBUTION BOX: ✓ (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: Even Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of leakage into or out of box,etc.): The D-box was level. No solids were present. PUMP CHAMBER: None (locate on site plan) Pumps in working order(yes or no): Alarms in working order(yes or no) Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): 8 Page 9 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 45 Bretwood Lane Centerville, AM Owner: Lino Crarieri Date of Inspection: July 28, 2003 SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required) If SAS not located explain why: Type ✓ leaching pits,number: I -4'x 6'(600 gal.)w/Y stone-per design plans leaching chambers,number: leaching galleries,number: leaching trenches,number, length: leaching fields,number,dimensions: overflow cesspool,number: Innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure, level of ponding,damp soil,condition of vegetation, etc.): The pit was dry. There were no signs offailure. The cover was 30"below grade. 1 used a video camera to conduct the inspection. CESSPOOLS: None (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth-top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments (note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.): PRIVY: None (locate on site plan) Materials of construction: Dimensions: Depth of solids: Comments(note condition of soil,signs of hydraulic failure, level of ponding, condition of vegetation, etc;): 9 ` Page 10 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 45 Bretwood Lane Centerville, MA Owner: Lino Crarieri Date of Inspection: July 28, 2003 Map: 168 Parcel: 121 SKETCH OF SEWAGE DISPOSAL SYSTEM Lot: 18 Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. A A*(-k # o 1 i A t a3 38:(v a a�• Ol 3 � 3 10 i� • Page 11 of 11 OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 45 Bretwood Lane Centerville, MA Owner: Lino Crarieri Date of Inspection: July 28, 2003 SITE EXAM Slope Surface water Check cellar Shallow wells Estimated depth to ground water 38 +/- feet Please indicate (check) all methods used to determine the high ground water elevation: Obtained from system design plans on record-If checked, date of design plan reviewed: Observed site(abutting property/observation hole within 150 feet of SAS) ✓ Checked with local Board of Health-explain: topographic and water contours maps Checked with local excavators, installers-(attach documentation) Accessed USGS database-explain: You must describe how you established the high ground water elevation: Using the Barnstable topographic map and the Cape Cod Commission water contours map the maps were showing approximately 38'+/-to ground water at this site. This report has been prepared and the system inspected and passed as of the date of inspection. This report is not a warranty or guarantee that the system will function properly in the future. There have been no warranties or guarantees, either expressed, written or implied, relating to the system, the inspection and/or this report. I1 I No_ � �s..............�-,......._ ��THEaCOMMONWEALTH OF MASSACHO�ETTS,. BOARD OF HEALTH .........OF.... .!;?-------------------•------.......-....-- Allp iration for Milioiitt1 Works Tontruaw" n ramit Appli n i h eby made for Permit to Construct or Repair ( ) an Individual Sewage Disposal System at .... mi __............ ...... °�-" -... TSyrc- .•----•-•-- - -•-•-- ------- Location-Address or Lot i r No � � . •_.... - o - v --.... 14o .. 0 ner Address Installer Address d Type of Building Size Lot__ 1 ------Sq. feet Dwelling—No. of Bedrooms...............___.._______.________.__Expansion Attic ('V�f Garbage Grinder 0`4 Other—Type of Building _�'�°!����?!�i�No. of persons........3................ Showers ( ) — Cafeteria ( ) a' Other fixtures --------------•-•----------•••• - W Design Flow........................./Z'o............gallons per person per day. Total daily flow---------__ ..Q.....................gallons. WSeptic Tank—Liquid capacity............gallons Length................ Width................ Diameter..........-..... Depth................ x Disposal Trench—No_____________________ Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No--------------------- Diameter..................... Depth below inlet.................... Total leaching area..................sq. ft. Z Other Distribution box (--) Dosing tank Percolation Test Results Performed by.....faze.____' _____________________ Date...... as Test Pit No. 1_____ ......minutes per inch Depth of Test Pit___ ........... Depth to ground water..y_4............___ G4 Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water________________________ 04 -------------• ----•••--•---•------------•--•------•-------------•--•----•---•---•--------------••--•-------•-••----...•-•---•-•----•-•••---•----_...•- 0 Description of Soil-----------d--- ---`- ........._44_'s''� °ei�_ t�� ---------•-------------------•-------------•---------------------.....---------- V --•------•-----••---._....-•----......--•-•-•-•••••••••••__•••- W -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- U Nature of Repairs or Alterations—Answer when applicable................................................................................................ _..-- •--•-•--••--•••-- ...--•-•-•••••-- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System.in accordance with the provisions of TITIL 5 of the State Sanitary Code— The undersigned further agrees not to place the system in operation until a Certificate of Compliance ha en issued by the board of health. Signed.. •l --•... •-=• ....... _ Date ApplicationApproved By.................................................................................................. ....................................... Date Application Disapproved for the following reasons:----•--------------•--•-------------•----•------------••--------------------•--••-----------------............ ....................••_.._......_..----•--....--•--••••••••-•---•--...........__.......-•--••-....._._._..--•-••-•-•••-•-•-•-•••••--••••--•-••••-•-•----•••-••-•-••-••--•••. ............................ 4} Date PermitNo..... ^:------- -------------------- Issued....................................................... Date 6r,Oro ........................ -THE;JCOMMONWEALTH OF MASSACHUSETTS. BOARD OF HEALTH ... ....................OF... ........... Appliration for Disposal Works Toustrurtion rumit Application is hereby made for a Permit to Construct or Repair an Individual Sewage Disposal System at: .........az:e�n4v ..... .................................................................................................. Location-Address Lot No. g, ✓ 70 .60,y -Vb ............ 4 ........................................................................................!�....... Owner Address r6J?_Z ........................... .....................................................................................Sq. .... ....... Type of Building Size Lot._Address .. ....... Installer feet Dwelling—No. of Bedrooms................3 . ..........................Expansion Attic (Ijl Garbage Grinder (1Vj Other—Type of Building of persons.........3............... Showers Cafeteria Other fixtures ......... --- -------- w Flow........................../--.,.-.,.,.,-,.,._gallons per person per day. Total daily flow............ ............................gallons. Septic Tank—.Liquid cap a.c ity--- ........gallons Length................ Width........___..... Diameter................ Depth..__....._..._.. 'Disposal Trench No. .................... Width.................... Total Length....._.__....._..... Total leaching area....................sq. f t. Seepage Pit No..................... Diameter........._......___. Depth below inlet_........_........._ Total leaching area..................sq. ft. Z Other Distribution box t-,-) Dosing tank ( ) 1.4 1­4 Percolation Test Results Performed by......e0e i!e...... Tlv!:4 ..................... Date.......ZV ... If....... ------------------------------ Test Pit No. I......ok.....minutes per inch Depth of Test Pit---14�.... Depth to ground water..241.0............ Test Pit No. 2................minutes per inch Depth of Test Pit..._....__......___. Depth to ground water.___._..._..._......__.. ................................................................................... ......................................."----------I.......... 0 Description of Soil...........jC..' czt '/at ......................................................... ...................... ....................OA;........................ --------------* .1. ............. t!7.4;>......................................................................................... ....................................................................................................................................7................................................................... U Nature of Repairs or Alterations—Answer when applicable--------------------­----..................................................................... ........................................................................................................................................................................................................ Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TLITIE 5 of the State Sanitary,Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has en issued by the li6ard of health. Signed... .... .... ....... .......................... ................... .. . ApplicationApproved By.................................................................................................. ....................Da.t e Date Application Disapproved for the following reasons:.............................................................................................................. .........................................6..�.,..............�...q................................ i.-............................................................................................................. -•- Date Permit No.....0 - ... .. .. .. Issue(L............. . . . ..Date THE COMMONWEALTH OF MASSACHUSETTS BOARD OF' HEALTH .........0 F........1 ..:. '��,, ....................... Tertifiratf of Toutplia"r r THIS K. TO URTIFY. That the Ii)(lividual Se�Iage Disposal System constructed ( 0-1�0` Repaired by............ _V2.�........ • ............................................................................................ Inst iller_..V ----------- at.........4.e.t....Jk............ ... ....... ... .. ..................................... :S el ... ..... has been installed in accordance with the provisions of TIl IZ 5 of T le State Sanitary Code as described in the application for Disposal Works Construction Permit No.... ........... dated------ THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE SYSTEM WILL FUNCTION S4TISFACTORY. DATE.................. ........... ------fl"Cn. ...................... - Inspector--:------__-- ------------------------------------------------------------------- THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH ........... ...........OF......... ......................................... No... FEE...................... Disposal rks Tonstrudion rrmit Permission is h reby granted....../,.4?......I........ ......... ....... to Construct or Repair an Individual Sewage Dis osal Sy t Z/1: S 1 „�f `! 47................................... C..........ier., ..............i....... at No....t 5. .�-5_ ... .4 .. X, Street as shown on the application for Disposal Works Construction Permit No...ZX�A*�. Dated.... ...... Board of Health DATE._Z."-�. ..... ... FORM 1255 A. M. SULKIN, _h.45�/G/V DAB". y 100 0' N ..• CAA P-BA t :GtiZ i' S D C V— OAII.Y F( oW .s l CCU x 3 330 Cr. P. D.I wa-T-z SEPTl c� TANK i. 330; X VFo f, • 445 C-.P.D. q:,E)Cew ...._ :.:. ..:: :.1.�'SC. 1�00 GAI_...TAIJK. .... .: •. G_—� _, (�.,� D IS POr.AL P.IT., ..use Coo GtA L ::P% • • --.•5lOEY�lAC��i�REA•. �32 S.F. . . � �. .�-- �o3`T'nu.� o Zo. -- 132 6oT1"oj..: .A;ftly A \1'3. t 60 P D ::9cSrG't`1• ��43 Q: P. D. � �"c,u►u���d� Y� .� 3 o p N RA�Tt ; 1° ii4 HIO ba. LESS l-2 �a+�s c PETER ` j - - t r4CH, "ID SULLIVAN -- t-0. 19733 t z 1 - `QO()` SIT p ` t , 1 ' tat 10Ab 41 /.vim G.4.L. 1 qAS' 2Z,' �;, Gales . ;may. Box 45� 1 SE'Pr�'G 45.3 tkgaN AA,! r ' o• Po 7- ; 7/rN�G �1 s ,W a Y'L•{ '3� s 5 ,3/¢dam Jx�� 44,1 -45 p/441 Eb IE �t W�4SHC-D „ PROM L lr SCALE T�',4T'771=`yo -ptgW S VeW.V .yE.�Eov c�R�Y�f W/rx,�T,y�'Sio�',c✓,ci� B.�Xr�,e �,c/y.E i,�o. T01•t/N 0�� �•. ' �-�-� .Git/I> /.S �VOT G�ST�.2Y/.GGc' a- G `ti.TC./utsr .41v M-157,22,- .> -r/�.EiYr-.Sv,2r/•C-'YA.c/O TyE o.��S.�� • S�K/.t/f/E,e�GiS/.S�4!/G��/pT-Q,E U.SE= . ' Ta EST�G/S.y ,Coy-�•�iYF.,s .. S �A'Ntl l:• --�---•3-..g Cl�('Zoosy __.... . � � � Nam; l►C5 X 3 z 33'o fr P. D.-tcy.,gkA WA-me- SEPT'M TANK s 330 X ISoyo -4qS G.P.0Exi'ii►� �? T ....._ :.:. ..::. :..t�'SC. I000 �+1.,...TA►J{C;.. .... ._ .. C.--' _, Q.i D%S PbCAL: ?-&—. - .V S E Cane'G A L �„- 3' ` . . I OEV�IAI /�ifZEA.. 132 S, f•�'. ?�co�au� 0 2o, 330 6%P. O. LCA )13 'S.F: .: i�r :l:o y 1.13 t3►.P. O. �A.: cSrG;N• AA o- F. D. 'F"GVH.�ti7,�•,�o►.� T . td�l c3N RAT MrN c2 Lzss i.•'Cir ems° PETER 11-4 W I0 . 000 �Z3�8s : : .. : ..- �� U Fy •- it . G.Op� 11V <5AI , BOX AA S 2Z/ '' t q N qq.S 45,1 S6-PrrG � `�' o• Po r, •0 7"AIV%G i !W1T14 �� v 5 -; .3�¢�►, � ,� 44,77 445 c,EQriF/Eo PG OT pG�4r✓ A, r : iiSHC-D • 1-6T 1 E•b •L.E fW �l�J 3'�`—G•-''I LoG,GT/Ors/ "f' Z r- 17-SZN r LL,-. PKO FI LG GE•E'r�.cY T�',QT'Th''�"�'ou c.��,r�na.�S.yaw.v ���� �-��.����. ��� �s��� �YE,�Eorc/ co.�lR�Y.f WiJ�/T,y�'Sio�,c✓ici� B.�xr�,e .,W4 I've. Aiv�.fEFll�/� ,� .2EQV/,�ENI�NrS o� Tiy� ,C�E6/.ST�.P=IJ.G4NO.S!/.e1Y�ryp,�s Toxiv o,�="`' ,�L2i•k6L� Q�� /S Ivor- G�Sr�,2li�.GGc a �1.�.� aAv ss,t��iY.ST,e- .. -!/�J.Ey1-.Sv,2�/EYflit/O TiSiE o�FS�1,� • S'S�K/X/,yE.e��N S,�v�000�it/pT-Q,E US.�p . Ta ES?J1l�G/Sh/ tar-G/NF-,S, y BAXTER & NYE, INC. Registered Land Surveyors and Civil Engineers 7 Parker Road/Osterville,Massachusetts 02655%Tel. (617)428-9131 WHAM C.NYE,R.L.S.-President RICHARD A.BAXTER,R.L.S.-Vice President PETER SULLIVAN,P.E.-Vice President-Engineering July 15 , 1986 Board of Health Town of Barnstable P.O. Box 534 Hyannis, MA 02601 RE: Lot 1'8 Bretwood Lane, Centerville Dear Board: I_n accordance with your request I witnessed an additional test hole at Lot 18. The test hole demonstrated that there is four feet of- dry previous material below the bottom of the leach pit . I trust this meets your present needs . Very truly yours, Peter Sullivan, P.E. PS/cas OF tj" CC: David M1Sauro PETER ��.� • SULLIVANCIO No. 29733 A'Pp �FSSIONAt MEMBERS OF CAPE COD SOCIETY OF PROFESSIONAL ENGINEERS AND LAND SURVEYORS/AMERICAN CONGRESS ON SURVEYING AND MAPPING MASSACHUSEITS ASSOCIATION OF LAND SURVEYORS AND CIVIL ENGINEERS TOWN OF BARNSTABLE L�.-FjTION r�- � 8r�-Twain AIL2. SEWAGE # Fr C1 L!/ 7 VILLAGE U/Tre, VAL ASSESSOR'S MAP & LOT/G,' /a INSTALLER'S NAME&PHONE NO. L..dT- $ SEPTIC TANK CAPACITY 16M) LEACHING FACILITY: (type) 47 x(P G&V (size) ? S73A4— NO.OF BEDROOMS BUILDER OR OWNER LJ^D Gr'A/'1 e r I PERMTTDATE: COMPLIANCE DATE: Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet Private Water Supply Well and Leaching Facility (If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leac 'ng facility) Feet Furnished by �Dn f�00 ��L p u r . i A B o r9339r(o � ASSESSOR'S MAP NO. P "` ate PARCEL f LQCATON �'1� SEWAGE PERMIT NO. �Olt - V I L L A G E \0 , ) ` '0�)lNSTA L LIE R'S NAME ADDRESS. cv- 0� �✓ S UILDE R OR OWNER d DATE PERMIT ISSUED D A T E COMPLIANCE ISSUED--71( �� �.o�t� oaa Cam`) �r� fi �, ;, � � G%S �� � � )� �, � � :�` � � � ._ I �I