Loading...
HomeMy WebLinkAbout0018 CENTERBROOK LANE - Health 18 CENTER BROOK LANE, CENTERV. A= i S/u 2J�grr�:E��oZ UPC 12534 NO. 2 1�QR �Aosr.�ov5�"� HABTINQS, MN Commonwealth of Massachusetts 0?157 y Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 3 18 Centerbrook Lane -G Property Address V1 Deborah Myers Owner Owner's Name information is Centerville Ma .02632 5-20-16 " required for every 1+_ page. City/Town State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When A. General Information / filling out forms on the computer, use only the tab 1. Inspector: key to move your cursor-do not Matthew Gilfoy use the return Name of Inspector key. B&B Excavation r� Company Name 374 Route 130 Company Address Sandwich Ma 02563 City/Town State Zip Code (508)477-0653 S113640 Telephone Number License Number B. Certification I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system.- Passes ❑ Conditionally Passes ❑ Fails ❑ Needs Further Evaluation by the Local Approving Authority 5-20-16 Inspector's Signature Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP) within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. t l5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 17 qjd IDS Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 0 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection B. Certification (cont.) Inspection Summary: Check A,B,C,D or E/always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: System was in working order at time of inspection. B) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is Centerville Ma 02632 5-20-16 required for every page. Cityfrown State Zip Code Date of Inspection B. Certification (cont.) ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. B) System Conditionally Passes (cont.): ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): C) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17 f c Commonwealth of Massachusetts W Title 5 Official Inspection Form o Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 18 Centerbrook Lane _ Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection B. Certification (cont.) 2. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance: ** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: D) System Failure Criteria Applicable to All Systems: You must indicate "Yes" or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than '/day flow t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments CM , 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection B. Certification (cont.) Yes No ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd- 10,000gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the questions in Section D. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA) or a mapped Zone II of a public water supply well If you have answered "yes" to any question in Section E the system is considered a significant threat, or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. t5ins•3/13 Title 5 Official Inspection Form Subsurface Sewage Disposal System•Page 5 of 17 f Commonwealth of Massachusetts W Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form - Not for Voluntary Assessments ° M 18 Centerbrook Lane Property Address Deborah Myers _ Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. CitylTown State Zip Code Date of Inspection C. Checklist Check if the following have been done. You must indicate"yes" or"no" as to each of the following: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (If they were not available note as N/A) ❑ ® Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ❑ ® Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] D. System Information Residential Flow Conditions: Number of bedrooms (design): No design Number of bedrooms (Actual) 3 plan DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): NA t5ins-3/13 Title 5 Official Inspection Form Subsurface Sewage Disposal System-Page 6 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments °M 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is Centerville Ma 02632 5-20-16 required for every _ page. City/Town State Zip Code Date of Inspection D. System Information Description: Number of current residents: 1 Does residence have a garbage grinder? ❑ Yes ® No Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ® Yes ❑ No Seasonal use? ❑ Yes ® No Water meter readings, if available last 2 ears usage d See below 9 ( Y 9 (gP ))� Detail: 2014- 5,000gallons 2015-22,000gallons Sump pump? ❑ Yes ® No Last date of occupancy: Current Date Commercial/Industrial Flow Conditions: Type of Establishment: NA Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Last date of occupancy/use: Date Other(describe below): General Information Pumping Records: Source of information: Owner- last pumped 2015 Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form. Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Approximate age of all components, date installed (if known) and source of information: 1985 Were sewage odors detected when arriving at the site? ❑ Yes ® No Building Sewer(locate on site plan): Depth below grade: 18 feet Material of construction: ❑ cast iron ® 40 PVC ❑ other(explain): Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): Septic Tank (locate on site plan): Depth below grade: 12 feet Material of construction: ® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1000gallons Sludge depth: 6 t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Septic Tank(cont.) Distance from top of sludge to bottom of outlet tee or baffle 30" Scum thickness 2 Distance from top of scum to top of outlet tee or baffle 6 Distance from bottom of scum to bottom of outlet tee or baffle 15" How were dimensions determined? Measured Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tank was in working order at time of inspection with liquid level equal to outlet invert. Tank is not in need of pumping at this time but should be pumped every two years for maintenance. Grease Trap (locate on site plan): Depth below grade: NA feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments M 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. Citylrown State Zip Code Date of Inspection D. System Information (cont.) Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: NA Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): *Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No l5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 11 of 17 Commonwealth of Massachusetts w Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments °M 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Distribution Box (if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0 11 Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): D-box is in working order at time of inspection with liquid level equal to outlet invert. D-box shows heavy signs of age but is not leaking at this time. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): NA * If pumps or alarms are not in working order, system is a conditional pass. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments °.H 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Type: ® leaching pits number: (1) 6'X6' ❑ leaching chambers number: ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions. ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): Leaching was in working order at time of inspection with no sign of hydraulic failure. Pit had standing water 4' below invert. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration NA Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction -- Indication of groundwater inflow ❑ Yes ❑ No t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17 I Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments °M 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Privy (locate on site plan): Materials of construction: NA Dimensions Depth of solids - — Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments �^M 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately REAR AF-42' BF-38' t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Fora Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 18 Centerbrook Lane _ Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City[Town State Zip Code Date of Inspection D. System Information (cont.) Site Exam: ® Check Slope ® Surface water ® Check cellar ® Shallow wells Estimated depth to high ground water: feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ❑ Observed site (abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health -explain: Per previous inspection report when USGS topo maps and charts were used ❑ Checked with local excavators, installers - (attach documentation) ❑ Accessed USGS database -explain: You must describe how you established the high ground water elevation: Info on file with BOH. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 17 Commonwealth of Massachusetts W Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbrook Lane Property Address Deborah Myers Owner Owner's Name information is required for every Centerville Ma 02632 5-20-16 page. City/Town State Zip Code Date of Inspection E. Report Completeness Checklist ® Inspection Summary: A, B, C, D, or E checked ® Inspection Summary D (System Failure Criteria Applicable to All Systems) completed ® System Information— Estimated depth to high groundwater ® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file 1 t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 17 Commonwealth of Massachusetts Title 5 Offi-cial Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ,M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip.Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. A. General Information 1. Inspector: � ;• f Shawn Mcelroy - Name of Inspector Upper Cape Septic Services Company Name P.O. Box 73 Company Address E. Falmouth MA 02536 City/Town State Zip Code 1-508-495-0905 S13971 Telephone Number License Number B. Certification I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site cr; sewage;disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of 2E Title 5 ( 10 CMR 15.000).The system: rs ® (Passes ❑ Conditionally Passes ❑ Fails ❑4�9.eds Further Eval tion b the Local Approving Authority 8-12-13 Inspector's Signature Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or Pas a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the- report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. UN" t5ins-3/13 Title 5 Official Inspec n orm:Subsurface Sewage Disposal System•Page 1 of 17 t Commonwealth of Massachusetts w Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbro M ok Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. Cityfrown State Zip Code Date of Inspection B. Certification (cont.) Inspection Summary: Check A,B,C,D or E I always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described S in 310 CMR 15.303 or in 310 CMR 15.304 exist.Any failure criteria not evaluated are indicated below.. Comments: System is in good working order with no sign of failure. B) System Conditionally Passes: El one or mores components as described in the "Conditional Pass"section need to be system replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health,will pass. Check the box for"yes", "no"or"not determined" (Y, N, ND) for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of-I, 7 i Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments ,M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. CityTrown State Zip Code Date of Inspection B. Certification (cont.) ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. B) System Conditionally Passes (cont.): ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ AND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): C) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is Centerville MA 02632 8-12-13 required for every page. City/Town State Zip Code Date of Inspection B. Certification (cont.) 2. 'System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance: ** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis must be attached to this form. 3. Other: D) System Failure Criteria Applicable to All Systems: You must indicate "Yes"or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than Y2 day flow t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 4 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection B. Certification (cont.) Yes No ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd- 10,000gpd. ❑ E The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the questions in Section D. Yes No ❑ ❑ the system Is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA) or a mapped Zone II of a public water supply well If you have answered "yes"to any question in Section E the system is considered a significant threat, or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 5 of 17 Commonwealth of Massachusetts Title 5 Official Inspectionform Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection C. Checklist Check if the following have been done. You must indicate "yes" or"no"as to each of the following: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? Z ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ❑ ® Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ❑ ® Existing Information. For example, a plan at the Board of Health. ® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] D. System Information Residential Flow Conditions: Number of bedrooms (design): 2 Number of bedrooms (actual): 2 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 220 t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 1? J Commonwealth of Massachusetts Title 5 Official Inspection Form m Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ^M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. Cityrrown State Zip Code Date of Inspection D. System Information Description: Number of current residents: 1 Does residence have a garbage grinder? ❑ Yes ® No Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ❑ Yes ® No Seasonal use? ❑ Yes ® No Water meter readings, if available (last 2 years usage (gpd)): Detail: Sump pump? ❑ Yes ® No Last date of occupancy: 8-2013 Date Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trapresent? P El Yes ❑ No Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 17 Commonwealth of Massachusetts a Title 5 Official Inspection Form _ o Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Last date of occupancy/use: Date Other(describe below): General Information Pumping Records: Source of information: Owner--Pumped 2011 Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: Maintenance Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology.Attach a copy of the current operation and maintenance contract(to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank.Attach a copy of the DEP approval. ❑ Other(describe): t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 8 of 1'r r Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ,M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Approximate age of all components, date installed (if known) and source of information: 1985 Were sewage odors detected when arriving at the site? ❑ Yes ® No Building Sewer(locate on site plan): Depth below grade: 18"feet Material of construction: ❑ cast iron ® 40 PVC ❑ other(explain): Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): Good condition. Septic Tank(locate on site plan): Depth below grade: 12"feet Material of construction: ® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1000 gal Sludge depth: 12" t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form.-Not for Voluntary Assessments ,M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 .page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Septic Tank(cont.) Distance from top of sludge to bottom of outlet tee or baffle 20" Scum thickness 0 Distance from top of scum to top of outlet tee or baffle 6" Distance from bottom of scum to bottom of outlet tee or baffle 16" How were dimensions determined? Tape Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tank is in good condition with baffles installed and no sign of leakage. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date t5ins-3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Ok Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ,M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): I *Attach copy of current pumping contract (required): Is copy attached? ❑ Yes ❑ No t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form o Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ,M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Distribution Box (if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0 Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Good condition with water at working level and no sign of back-up from pit. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No* Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): * If pumps or alarms are not in working order, system is a conditional pass. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is Centerville MA 02632 8-12-13 required for every ' page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Type: ® leaching pits number: 1-1000 gal ❑ leaching chambers number: ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): Leach pit in good condition and empty at inspection with stain line at 36" below inlet invert. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every .Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately .10 L�_ -+ r Coo e F t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 ,page. City/Town State Zip Code Date of Inspection D. System Information (cont.) Site Exam: ❑ Check Slope ❑ Surface water ❑ Check cellar ❑ Shallow wells Estimated depth to high ground water: 20 feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ® Observed site (abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health -explain: ® Checked with local excavators, installers- (attach documentation) ® Accessed USGS database- explain: You must describe how you established the high ground water elevation: USGS and town maps show groundwater at greater than 20'. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 16 of 17 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments °M 18 Centerbrook Ln Property Address Debra Meyers Owner Owner's Name information is required for every Centerville MA 02632 8-12-13 page. City/Town State Zip Code Date of Inspection E. Report Completeness Checklist ® Inspection Summary: A, B, C, D, or E checked ® Inspection Summary D (System Failure Criteria Applicable to All Systems) completed ® System Information—Estimated depth to high groundwater ® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file t5ins•W3 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 17 of 17 CP T f6J5 COMMONWEALTH OF MASSACHUSETTS Z/gs EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS (� DEPARTMENT OF ENVIRONMENTAL PROTECTION TITLE 5 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM PART A CERTIFICATION Property Address: 18 Centerbrook Lane Centerville, MA 02632 Owner's Name: Martha Twombly Owner's Address: Date of Inspection: July 14, 2005 Name of Inspector: (Please Print) Janes M. Ford s_ Company Name: James M. Ford Mailing Address: P.O.Box 49 C;D Osterville,MA 02655-0049 T_ Telephone Number: (508)862-9400 :z `= CERTIFICATION STATEMENT r I certify that I have personally inspected the sewage disposal system at this address and that the in rmation�reported 1 below is true,accurate and complete as of the time of the inspection. The inspection was performe. based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system: ✓ Passes Conditionally Passes Needs Further Evaluation by the Local Approving Authority Fails Inspector's Signature: Date: July 20, 2005 The system inspector shall subm copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving authority. Notes and Comments ****This report only describes conditions at the time of inspection and under the conditions of use at that time. This inspection does not address how the system will perform in the future under the same or different conditions of use. Title 5 Inspection Form 6/15/2000 page 1 to Page 2 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twombly Date of Inspection: July 14, 2005 Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D A. System Passes: ✓ I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: B. System Conditionally Passes: One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass. Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"riot determined",please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not)is structurally unsound,exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. System will pass inspection if (with approval of Board of Health): broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced ND explain: The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed ND explain: 2 Page 3 of I 1 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twombly Date of Inspection: July 14, 2005 C. Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health,safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh 2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the system is functioning in a manner that protects the public health,safety and environment: The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance "This system passes if the well water analysis,performed at a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: 3 Page 4 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION (continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twombly Date of Inspection: July 14, 2005 D. System Failure Criteria applicable to all systems: You must indicate either"yes"or"no"to each of the following for all inspections: Yes No ✓ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ✓ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool ✓ Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ✓ Liquid depth in cesspool is less than 6"below invert or available volume is less than 'h day flow ✓ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped_. ✓ Any portion of the SAS,cesspool or privy is below high ground water elevation. ✓ Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ✓ Any portion of a cesspool or privy is within a Zone 1 of a public well. ✓ Any portion of a cesspool or privy is within 50 feet of a private water supply well. ✓ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.] No (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E. Large System: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. You must indicate either"yes"or"no"to each of the following: (The following criteria apply to large systems in addition to the criteria above) Yes No the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped Zone II of a public water supply well If you have answered"yes"to any question in Section E the system is considered a significant threat,or answered "yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 4 Page 5 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twonibly Date of Inspection: July 14, 2005 Check if the following have been done: You must indicate"yes"or"no"as to each of the following: Yes No ✓ Pumping information was provided by the owner,occupant,or Board of Health ✓ Were any of the system components pumped out in the previous two weeks? ✓ _ Has the system received normal flows in the previous two week period? ✓ Have large volumes of water been introduced to the system recently or as part of this inspection? ✓ _ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ✓ Was the facility or dwelling inspected for signs of sewage back up? ✓ Was the site inspected for signs of break out? ✓ _ Were all system components,excluding the SAS, located on site? ✓ _ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum? ✓ _ Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS)on the site has been detennined based on: Yes No ✓ _ Existing information. For example,a plan at the Board of Health. ✓ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(3)(b)]. 5 Page 6 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twonibly Date of Inspection: July 14, 2005 FLOW CONDITIONS RESIDENTIAL Number of bedrooms(design): 3 Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 Number of current residents: 3 Does residence have a garbage grinder(yes or no): No Is laundry on a separate sewage system(yes or no): n/a [if yes separate inspection required] Laundry system inspected(yes or no): No Seasonal use(yes or no): No Water meter readings, if available(last 2 years usage(gpd)): Unavailable Sump Pump(yes or no): No Last date of occupancy: Currently occupied COMMERCIAL/INDUSTRIAL Type of establishment: Design flow(based on 310 CMR 15.203): pd Basis of design flow(seats/persons/sgft,etc.): Grease trap present(yes or no): Industrial waste holding tank present(yes or no) Non-sanitary waste discharged to the Title 5 system(yes or no): Water meter readings, if available: Last date of occupancy/use: OTHER(describe): GENERAL INFORMATION Pumping Records Source of information: Pumped in 2002-per owner;Pumped after inspection for maintenance Was system pumped as part of the inspection(yes or no): No If yes,volume pumped: _gallons--How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM ✓ Septic tank,distribution box,soil absorption system Single cesspool Overflow cesspool Privy Shared system(yes or no) (if yes, attach previous inspection records, if any) Inno vative/A Item ative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight Tank Attach a copy of the DEP approval Other(describe): Approximate age of all components,date installed(if known)and source of information: Date of installation unknown Were sewage odors detected when arriving at the site(yes or no): No 6 Page 7 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twomblv Date of Inspection: July 14, 2005 BUILDING SEWER(locate on site plan) Depth below grade: Materials of construction: —cast iron —40 PVC —other(explain): Distance from private water supply well or suction line: Comments (on condition of joints,venting,evidence of leakage,etc.): SEPTIC TANK: ✓ (locate on site plan) Depth below grade: 12" Material of construction: ✓ concrete —metal —fiberglass —polyethylene ex —other(explain) ) If tank is metal list age: Is age confirmed by a Certificate of Compliance(yes or no): (attach a copy of certificate) Dimensions: 1000 gal. Sludge depth: 2" Distance from top of sludge to bottom of outlet tee or baffle: 30" Scum thickness: 6" Distance from top of scum to top of outlet tee or baffle: 6" Distance from bottom of scum to bottom of outlet tee or baffle: 10" How were dimensions determined: Measurin-a stick Comments(on pumping recorn mendations, inlet and outlet tee or baffle condition,structural integrity,liquid levels as related to outlet invert, evidence of leakage, etc.): Tees were present. The liquid level was even with the outlet invert There did not appear to be any signs of leakage The tank was dumped after the inspection for maintenance. GREASE TRAP: None (locate on site plan) Depth below grade: Material of construction: _concrete _metal —fiberglass —polyethylene —other (explain): Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: Date of last pumping: Corn ments(on pumping recommendations,inlet and outlet tee or baffle condition,structural integrity, liquid levels as related to outlet invert, evidence of leakage,etc.): 7 Page 8 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twonibly Date of Inspection: July 14, 2005 TIGHT or HOLDING TANK: None (tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: _concrete _metal _fiberglass _polyethylene _other(explain): Dimensions: Capacity: gallons Design Flow: gallons/day Alarm present(yes or no): Alarm level: Alarm in working order(yes or no): Date of last pumping: Comments(condition of alarm and float switches,etc.): DISTRIBUTION BOX: ✓ (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: Even Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover, any evidence of leakage into or out of box,etc.): The D-box was level. No solids were present. PUMP CHAMBER: None (locate on site plan) Pumps in working order(yes or no): Alarms in working order(yes or no) Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): 8 Page 9 of I 1 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twonibly j Date of Inspection: July 14, 2005 SOIL ABSORPTION SYSTEM(SAS): ✓ (locate on site plan,excavation not required) If SAS not located explain why: Type ✓ leaching pits,number: 1 -6'x 6'(1000,dal.) leaching chambers,number: leaching galleries,number: leaching trenches,number, length: leaching fields,number,dimensions: overflow cesspool,number: Innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure, level of ponding,damp soil,condition of vegetation, etc.): The leach pit had 6"ofliauid on the bottom The scum line was approximately]'up from the bottom There did not appear to be any suns offailure. CESSPOOLS: None (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth-top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments (note condition of soil,signs of hydraulic failure, level of ponding,condition of vegetation, etc.): PRIVY: None (locate on site plan) Materials of construction: Dimensions: Depth of solids: Comments(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.): 9 • Page 10 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twoinbly Date of Inspection: July 14, 2005 SKETCH OF SEWAGE DISPOSAL SYSTEM Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. 1 a A C 3 3L 3a Y y/ 3�� 10 Page 11 of 11 OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 18 Centerbrook Lane Centerville, MA Owner: Martha Twombly Date of Inspection: July 14, 2005 SITE EXAM Slope Surface water Check cellar Shallow wells Estimated depth to ground water 20 +/- feet Please indicate(check)all methods used to determine the high ground water elevation: Obtained from system design plans on record-If checked,date of design plan reviewed: Observed site(abutting property/observation hole within 150 feet of SAS) ✓ Checked with local Board of Health-explain: topographic and water contours maps Checked with local excavators,installers-(attach documentation) Accessed USGS database-explain: You must describe how you established the high ground water elevation: Using Barnstable topographic and water contours maps, the maps were showing approximately 20'+/-to-around water at this site. This report has been prepared and the system inspected and passed as of the date of inspection. This report is not a warranty or guarantee that the system will function properly in the future. There have been no warranties or guarantees, either expressed, written or implied, relating to the system, the inspection and/or this report. 11