SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION
MAP 188 PAR 106
PROPERTY ADDRESS: 54 EMERSON WAY, CENTERVILLE ADDRESS OF OWNER:
DATE OF INSPECTION: NOVEMBER 19, 1999 PETER E. RYAN TRUST
NAME OF INSPECTOR : JAMES D. SEARS
I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 9310 CMR 15.000)
COMPANY NAME: A&B Canco
MAILING ADDRESS: 350 Main Street,West Yarmouth,MA 02673
TELEPHONE NUMBER: 5( 08)775-2800
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,
accurate and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper
function and maintenance of on-site sewage disposal systems. The system:
X PASSES
CONDITIONALLY PASSES
NEEDS FURTHER EVALUATION BY THE LOCAL APPROVING AUTHORITY
FAILS
INSPECTORS SIGNATURE: DATE: NOVEMBER 24, 1999
The system Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP) within thirty(30)
days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the
system owner shall submit the report to the appropriate regional office of the Department of Environmental Protection. The original
should be sent to the system owner and copies sent to the buyer,if applicable and the approving authority.
NOTES AND COMMENTS:
I
SITE OVER ALL PASSES, INSPECTION OF SYSTEM IS BASED ON CONDITION OF SYSTEM AT THE TIME
OF THE INSPECTION.THERE IS NO GUARANTEE ON THE LIFE OF THE SYSTEM.
revised 9/2/98 1
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIVICATION(continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
INSPECTION SUMMARY: Check A, B, C, orD:
A] SYSTEM PASSES: X
I have not found any information which indicates that the system violates any of the failure criteria as defined in 310 CMR
15.303. Any failure criteria not evaluated are indicated below.
COMMENTS:
B SYSTEM CONDITIONALLY PASSES: N/A
One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The
System,upon completion of the replacement or repair,as approved by the Board of Health will pass.
Indicate yes,no,or not determined(Y,N,or ND). Describe basis of determination in all instances. If"not determined",explain why not)
The septic tank is metal,unless the owner or operator has provided the system inspector with a copy of a Certificate
Of Compliance(attached)indicating that the tank was installed within twenty(20) years prior to the date of the
inspection;or the septic tank,whether or not metal,is cracked,structurally unsound,shows substantial infiltration or
exfiltration,or tank is failure is imminent. The system will pass inspection if the existing septic tank is replaced with a
conforming septic tank as approved by the Board of Health.
Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed
pipe(s)or due to a broken,settled or uneven distribution box. The system will pa
pass inspection if(with approval of the Board of Health).
broken pipe(s)are replaced
obstruction is removed
distribution box is leveled or replaced
The system required pumping more than four times a year due to broken or obstructed
pipe(s). The system will pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
revised 9/2/98 2
• SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
C] FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH: N/A
Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to
protect the public health,safety and the environment.
1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES IN ACCORDANCE WITH 310 CMR 15.303
(1)(b)THT THE SYSTEM IS NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND SAFETY
AND THE ENVIRONMENT:
Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER,IF ANY)
DETERMINES THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND
SAFETY AND THE ENVIRONMENT:
The system has a septic tank and soil absorption system(SAS)and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
The system has a septic tank and soil absorption system and the SAS is within a Zone
1 of a public water supply well.
The system has a septic tank and soil absorption system and the SAS is within 50 feet
of a private water supply well.
The system has a septic tank and soil absorption system and the SAS is less than 100
feet but 50 feet or more from a private water supply well,unless a well water analysis for coliform
bacteria and volatile organic compounds indicates that the well is free from pollution from that facility
and the presence of ammonia nitrogen and nitrate nitrogen and is equal to or less than 5 ppm. Method
used to determine distance (approximation not valid).
3) OTHER
revised 9/2/98 3
r
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Address: 54 EMERSON WAY Property Addre , CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
D]SYSTEM FAILS: N/A
You must indicate either"Yes'or"No" to each of the following:
I have determined that one or more of the following failure conditions exist as described in 310 CMR
16.303. The basis for this determination is identified below. The Board of Health should be contacted to
Determine what will be necessary to correct the failure.
Yes No
Backup of sewage into facility or system component due to an overloaded or clogged
SAS or cesspool.
Discharge or ponding of effluent to the surface of the ground or surface waters due to an over-
loaded or clogged SAS or cesspool.
Static liquid level in the distribution box above outlet invert due to an overloaded or clogged
SAS or cesspool.
Liquid depth in cesspool is less than 6"below invert or available volume is less than'%day flow
Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s)
Number of times pumped
Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater
elevation.
Any portion of a cesspool or privy is within 100 feet of surface water supply or tributary to a
surface water supply.
Any portion of a cesspool or privy is within a Zone I of a public well.
Any portion of a cesspool or privy is within 50 feet of a private water supply well.
Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private
water supply well with no acceptable water quality analysis. If the well has been analyzed to be acceptable,attach
copy of well water analysis for coliform bacteria,volatile organic compounds,ammonia nitrogen and nitrate
nitrogen.
E) LARGE SYSTEM FAILS: N/A
You must indicate either"Yes"or"No"as to each of the following:
The following criteria apply to large systems in addition to the criteria above:
The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a
significant threat to public health and safety and the environment because one or more of the following conditions exist:
Yes No
the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or
mapped Zone II of a public water supply well)
The owner or operator of any such system shall upgrade the system in accordance with 310 CMR 15.304(2). Please consult the local
regional office of the Department for further information.
revised 9/2/98 4
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
Check if the following have been done:You must indicate either"Yes"or"No"as to each of the following:
Yes No
X Pumping information was provided by the owner,occupant,or Board of Health.
X None of the system components have been pumped for at least two weeks and the system
has not been receiving normal flow rates during that period. Large volumes of water have not been introduced
into the system recently or as part of this inspection.
N/A As built plans have been obtained and examined. Note if they are not available with N/A.
X The facility or dwelling was inspected for signs of sewage back-up.
X The system does not receive non-sanitary or industrial waste flow.
X The site was inspected for signs of breakout.
X All system components,including the Soil Absorption System,have been located on the site.
X The manholes were uncovered,opened,and the interior was inspected for condition of tees,material of
construction,dimensions,depth of liquid,depth of sludge,depth of scum. The size and location of the Soil
Absorption System on the site has been determined based on:
X Existing information.Ex.Plan at B.O.H.
X Determined in the field(if any of the failure criteria related to Part C is at issue,approximation
of distance is unacceptable)[15.302(3)(b)] _
X The facility owner(and occupants,if different from owner)were provided with information on
the proper maintenance of Sub-Surface Disposal System.
I
revised 9/2/98 5
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 54 EMERSON WAY,CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
FLOW CONDITIONS
RESIDENTIAL:
Design flow: 220 g.p.d./bedroom for S.A.S.
Number of bedrooms(design) 2&2 Number of bedrooms(actual): 2
Total DESIGN flow
Number of current residents: 0
Garbage grinder(yes or no): NO
Laundry(separate system) (yes or no): N/A If yes,separate inspection required
Laundry system inspected(yes or no): N/A
Seasonal use(yes or no) YES
Water meter readings,if available(last two(2)year usage(gpd): 1998 4,000 GALLONS/1997 5,000 GALLONS
Sump Pump(yes or no): NO
Last date of occupancy: N/A
COMMERCIAL/INDUSTRIAL:
Type of establishment:
Design flow: Gpd(Based on 16.203)
Basis of design flow
Grease trap present:(yes or no):
Industrial Waste Holding Tank present:(yes or no)
Non-sanitary waste discharged to the Title 5 system:(yes or no)
Water meter readings,if available:
Last date of occupancy,
OTHER:(Describe)
Last date of occupancy:
GENERAL INFORMATION
PUMPING RECORDS and source of information:
N/A
System pumped as part of inspection:(yes or no) NO
If yes,volume pumped: gallons
Reason for not pumping BOTH POOLS DRY
TYPE OF SYSTEM
Septic tank/distribution box/soil absorption system
X Cesspool
X Overflow cesspool
Privy
Shared system(yes or no)(if yes,attach previous inspection records,if any)
I/A Technology etc.Attach copy of up to date operation and maintenance contract.
Tight Tank Copy of DEP Approval
Other
APPROXIMATE AGE of all components, date installed (if known)and source of information:
UNKNOWN
Sewage odors detected when arriving at the site:(yes or no) NO
revised 9/2/98 6
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
BUILDING SEWER: N/A
(Locate on site plan)
Depth below grade:
Material of construction _ cast iron _ 40 PVC _ other(explain)
Distance from private water supply well or suction line
Diameter
Comments:(condition of joints,venting,evidence of leakage,etc.)
SEPTIC TANK: N/A
(Locate on site plan)
Depth below grade:
Material of construction concrete — metal _ Fiberglass _ Polyethylene _ other(explain)
If tank is metal,list age Is age confirmed by Certificate of Compliance (Yes/No)
Dimensions:
Sludge depth:
Distance from top of sludge to bottom of outlet tee or baffle:
Scum thickness:
Distance from top of scum to top of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle:
How dimensions were determined
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural
integrity,evidence of leakage,etc.)
GREASE TRAP: N/A
(locate on site plan)
Depth below grade:
Material of construction _ concrete _ metal _ Fiberglass _ Polyethylene _ other(explain)
Dimensions:
Scum thickness:
Distance from top of scum to top of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle:
Date of last pumping:
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural
integrity,evidence of leakage,etc.)
revised 9/2/98 7
• SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
TIGHT OR HOLDING TANK: N/A (Tank must be pumped prior to,or at time,of inspection)
(Locate on site plan)
Depth below grade:
Material of construction _ concrete _ metal _ Fiberglass _ Polyethylene _ other(explain)
Dimensions:
Capacity: Gallons
Design flow: gallons/day
Alarm present
Alarm level: Alarm in working order Yes; No
Date of previous pumping:
Comments:
(condition of inlet tee,condition of alarm and float switches,etc.)
DISTRIBUTION BOX: N/A
(locate on site plan)
Depth of liquid level above outlet invert:
Comments:
(note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box,etc,)
PUMP CHAMBER: N/A
(locate on site plan)
Pumps in working order:(Yes or No)
Alarms in working order(Yes or No)
Comments:
(note condition of pump chamber,condition of pumps and appurtenances,etc.)
I
revised 9/2/98 8
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
SOIL ABSORPTION SYSTEM (SAS): X
(locate on site plan,if possible;excavation not required,but may be approximated by non-intrusive methods)
If not located, explain:
Type:
Leaching pits,number:
Leaching chambers,number:
Leaching galleries,number:
Leaching trenches,number,length:
Leaching fields,number,dimensions:
Overflow cesspool,number, 1
Alternative system:
Name of Technology:
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.)
OVERFLOW POOL,7'6"DEEP,CEMENT COVER 10"BELOW GRADE.POOL DRY,CLEAN BOTTOM AND WALLS.NO INLET
TEE,NO OUTLETS. POOL HAS HAD LITTLE USE.
CESSPOOLS: X
(locate on site plan)
Number and configuration: 1
Depth-top of liquid to inlet invert: DRY
Depth of solids layer: DRY
Depth of scum layer: 6'
Dimensions of cesspool: BLOCK
Materials of construction: NO
Indication of groundwater:
inflow(cesspool must be pumped as part of inspection)
Comments::
(note condition of soil,signs of hydraulic failure,,level of ponding,condition of vegetation,etc.)
MAIN POOL BLOCK 6'DEEP, DRY,CEMENT COVER 4"BELOW GRADE.ONE INLET,NO TEE,ONE OUTLET WITH TEE.
PRIVY: N/A
(locate on site plan)
Materials of construction: Dimensions:
Depth of solids:
Comments:
(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
revised 9/2/98 9
c
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent references landmarks or benchmarks
locate all wells within 100'(locate where public water supply comes into house)
r,2 .
L C
revised 9/2/98 10
TOWN OF BARNSTABLE +
LOCATION SY /l9£A°5��' L.i SEWAGE #
VILLAGE C°£/LT ASSESSOR'S MAP Cz LOT 17?-Alsr
NAME Sz PHONE NO. A & B CANCO 775-6264
SEPTIC TANK CAPACITY
LEACHING FACILITY:(type) ®®L (size)
NO. OF BEDROOMS PRIVATE WELL OR PUBLIC WATER
BUILDER OR OWNER 1p f £R
DATE
DATE COMPLIANCE ISSUED:
VARIANCE GRANTED: Yes No
REAR
s� �
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 54 EMERSON WAY, CENTERVILLE
Owner: PETER E. RYAN TRUST
Date of Inspection: NOVEMBER 19, 1999
NRCS Report name
Soil Type
Typical depth to groundwater
USGS Date website visited
Observation Wells checked
Ground water depth: Shallow Moderate Deep
SITE EXAM Slope
Surface water
Check Cellar
Shallow wells
Estimated Depth to no groundwater 11 Feet
Please indicate all the methods used to determine High Groundwater Elevation:
Obtained from Design Plans on record
X Observation of Site(Abutting property,observation hole,)
Determine it from local conditions
Check with local Board of health
Check FEMA Maps
Check pumping records
Check local excavators,installers
Use USGS Data
Describe in your own words how you established the High Groundwater Elevation.(Must be completed)
NOTE: HAND DUG TEST HOLE. TEST HOLE T BELOW BOTTOM OF OVERFLOW POOL. NO WATER AT 11'.
ALSO SITE HIGH.