Loading...
HomeMy WebLinkAbout0046 GREAT HILL DRIVE - Health 46 Great Hill ®rive Centerville A = 173 082 S° �uv UPC 10259 ' No. H� 1_s_ NA&TINQ/. UN J- No. t n Fee THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: Yes PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS 01ppYication for 30i!5poga16pgtem Construction Permit Application for a Permit to Construct( )Repair( )Upgrade( /Abandon( ) El Complete System Individual Components Location Address or Lot No. Owner's Name,Address and Tel.No. Assessor'sMap/Parcel � 61mrAIMPI 6e�W2� �,�'4e Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No. Type of Building: _ Dwelling No.of Bedrooms Lot Size ��56 sq.ft. Garbage Grinder( ® Other Type of Building &No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow ILPI gallons per day. Calculated daily flow gallons. Plan Date Number of sheets f Revision Date Title Size of Septic Tank 10 00 ,Eif%5 iAg! Type of S.A.S. — `✓-ell, , Description of Soil il/I G l,7,2 �rS Nature of Repairs or Alterations(Answer when applicable) Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued b his Bo d of alth. J Signed Date �` - /,0 Application Approved by Date /off ;? 6 2 Application Disapproved for the following reasons Permit No. 2 U 0 A- S9r(' Date Issued ;P a � --Alm. --- ---------- �: 17.3— y No. '2s, s:.. ;,M Fee A i THE COMMONWEALTH OF MASSACHUSETTS Entered in compYes uter: l� #' PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLES MASSACHUSETTS 21ppriration for Oigool 6potent Construction Permit Application for a Permit to Construct( _ )Repair( )Upgrade(Abandon( ) ❑Complete System ®/Individual Components ~� Location Address or Lot No. Owner's Name,Address and Tel.No. Assessor's Map/Parcel �� �" " � AA Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No. CeWK� -���Y Type of Building: r� Dwelling No.of Bedrooms ✓ Lot Size 1132K3 sq.ft. Garbage Grinder( D Other Type of Building a e. / 1°f�&-"No.of Persons i Showers( ) Cafeteria( ) Other Fixtures f Design Flow ll/ gallons per day. Calculated daily flow gallons. Plan Date /Z- 15—M Z Number of sheets / Revision Date Title n Size of Septic Tank //7 00 �if'�5 /�� Type of S.A.S. i Description of Soil y 3. S-�1' �'•�3. .Y, s f Nature of Repairs or Alterations(Answer when applicable) Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issu9db1his Board of ealth. Signed Date 1 Z/,>.� 02 Application Approved by Date /a � /a 2 Application Disapproved for the following reasons Permit No. 2 U 0 4 Date Issued /11.2 Z o 2- THE COMMOAWEALTHtOF MASSACHUSETTS k BARNSTABLE, MASSACHUSETTS (Certificate of (Compliance THIS IS TO CERTIFY that th�O ��sp osal System Constructed( )Repaired ( )Upgraded Abandoned( )by �� at y fl�?�G>Y�` /�� .��� e�l_Xl has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. aol?-S 9,Y dated I a Installer 1 Designer AQ The issuance of this��pe t shall not-be construed as a guarantee that the sys'te/m-w1i�ll/�funretio�as d-signed Date J 7 u.� e Inspector --------------------------------------- No. a0d.2- .S-yd Fee l THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION - BARNSTABLES MASSACHUSETTS Oi6po5af *pgtem (fongtruction Permit Permission is hereby granted to Construct Repair i)Upgrade . Abandon( ) System located at and as described in the above Application for Disposal System Construction Permit. The applicant recognizes his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construction must be completed within three years of the date of th's permit. n Date:_ 1 k 17 Approved by TOWN OF BARNSTABLE C� LOCATION SEWAGE # r9Y VILLAGE 1,,W�/c ASSESSOR'S MAP & LOT 3 INSTALLER'S NAME&PHONE NO. ��r � `ag5frvr�io✓ 5(ZB-g3�L SEPTIC TANK CAPACITY :&4 LEACHING FACIUM (type) l6) (size) 9 A 9or r X 6 NO.OF BEDROOM 3 BUILDER OR R PERMITDATE:_ /"/1/O0- COMPLIANCE DATE: Separation Distance Between the: !, Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility 7 Feet Private Water Supply Well and Leaching Facility (If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) Feet Furnished by Cg�e Rn r� ur d�V � 1 TOP FNDN. Y 7i.7' SYSTEM PROFILE TEST HOLE LOGS ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO ENGINEER; A.H. OJALA, PE Gocus MINIMUM .75' OF COVER OVER PRECAST WITHIN 6 OF FIN. GRADE DAVID STANTON 2% SLOPE REQUIRED OVER SYSTEM 68 0' WITNESS: DATE: 12/11/02 RUN PIPE LEVEL & FOR FIRST 2' 2" DOUBLE WASHED PEASTONE < 2 MIN INCH IN M 1000 PERC. RATE - / ( S) XI TIN � - z E S G I GALLON SEPTICI 64 _ CLASS I 8 III SOILS P1039265.4P)TANK (H- 10 PR , (RE-USE 64. 6 r _ 0.5a 6t. 8 0 6 .5' off' MECHANICAL H OR 6" CRUSHED STONE COMPACTION. (15.221 [21) �rl ELEV. .[-`-], ELEV., of DEPTH OF FLOW = 4' (_L-7. SLOPE) ( 1 % SLOPE) 3/4" TO 1 1/2" DOUBLE WAS 1E?J STONE 6� A, 68.0 tiroF TEE SIZES: A INLET DEPTHS loop _ RO OUTLET DEPTH ��., 4' 12" 12" LOCATION MAP NO SCALE L£Ar,HtNG FOUNDATION- EXIST. SEPTIC TANK 106' D' BOX 3) ASSESSORS MAP 173 PARCEL 82 FAC!LI `Y USE G-W AT EL. 59.5' (MOTTLES) 24" / 24" *EXIST. SEPTIC TANK MUST BE RAISED A MINIMUM 0.5' (INVERT OUT TO BE MINIMUM ELEVATION 65.4' TO PROVIDE GRAVITY FLOW T SEPTIC DESIGN: (GARBAGE DISPOSER IS ____NOT ALLOWED ______) +� F,Y / 60" 6 AND MAINTAIN 4 SEPARATION 0 72 HIGH GROUNDWAATER) DESIGN FLOW: 3_ BEDROOMS ( 110 GPD) 330 GPD USE A30 GPD DESIGN FLOW SEPTIC TANK: 3-30 GPD (_ _) =660 - GALLONS USE A 1000_ GALLON SEPTIC TANK (RE-USE EXIST - / ,USE G-W AT EL. LEACHING: MUST BE RAISED) 96 102 59.5 8.5' (MOTTLES) SIDES: 143.5 + s.s3Z2 A.ss)_- (.74-) w 60__ GPD C3 STaNED C3 43 5 x 8.83 74 _ 284 WATER AT 144" MS SAND MS BOTTOM:----------- (___) - ___- GPD 156" 2.5Y 5/4 2.5Y 5/4 150 TOTAL: 465_ S.F. 344 GPD NOTES: USE (6) STANDARD INFILTRATORS WITH 3' STONE ALL 15.405 t is REQUEST REDUCTION IN SEPARATION TO AROUND (NONE UNDER) GROUNDWATER, 5' TO 4' APPROXIMATE NGVD - 1 . DATUM IS LXIS I NG 2. rM�3i'�ii ;IrAL WATtR 15 - rn•os _, 8 t:,.46' LEGEND 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT, 28 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 . 7 .0 +66.33 11; 100.0 PROPOSED SPOT ELEVATION 5: PIPE JOINTS TO BE MADE WATERTIGHT. LOT 35 �7 43,565f SQ. FT. r- '� 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, I 9.55 +66.20 +67.46 1.00t ACRES vZ d 100x0 EXISTING SPOT. ELEVATION ENVIRONMENTAL CODE TITLE V. 71.00 O� ----- - Gg �� �<" 100 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE �H� -10 PROPOSED CONTOUR USED FOR LOT LINE STAKING. 70.$3 0.5 ���UT� s7 = - �9 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40--4" PVC. + v� 100 EXISTING CONTOUR 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT -o ------.:� N� INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED 70.68! � 6" CRA�APPLE DECK ,p FROM BOARD OF HEALTH. W .9B 3 Q EXIST. DWELL. --� 10. LEACH FACILITY TO BE PUMPED AND FILLED WITH CLEAN SAND +66.86�.�1�.., -� p TF = 71.7' OR REMOVED AS NECESSARY, I +".Z3 W-n 6�� _ 030 A I \ +68.71 f fsis' 6 GRAVEL D VE � TITLE SITE P ►., I rn 99 rn 60 8. +69.27 BENCH MARK - CORNER OF t� LAN +69.57 68.26 , -E + ^6 9 CONC. APRON EL. - 70.4 emu, OF 0.02 +68.84 37 10" CEDAR H� Q 6 . . 46 GREAT HILL DRIVE fty I EXIST RE USE EXISTING SEPTIC TANK - (MUST BE IN THE TOWN OF. T 67 LEACH RAISED MINIMUM 0.5') AR (CENTERVILLE) BARNSTABLE / + 7 I +67.58 ' 6" HOLLIES 6� PREPARED FOR: BORTOLOTTI CONSTRUCTION/BROWN I � +66.4 6 69.76 0.00 337.72 <o<O : +65.42 BOARD OF HEALTH 30 0 30 60 90 Feet C° rn r MA G DATE ai +66.31 1 SCALE: " T 3C DATE: DECEMBER 15, 2002 69.42 +67.49 6� +65.45 +66.48 rn +68.49 00 5' REMOVAL OF UNSUITABLE SOIL off 508-362-4541 (0 <0 REQUIRED AROUND PERIMETER OF fax 508 362-9880 LEACHING FACILITY, DOWN TO C3 LAYER (SEE TEST HOLES). REPLACE WITH CLEAN MED. SAND. down cape engineering, inc. ,�}=-• ,: -� ` Aw lH Ur nr r� it lh OF �. CIVIL ENGINEERS AHNE NEH. 6° H. G LAND SURVEYORS r � ni LA oJALA Nc. 634 1 , " CIVIL N 9139 main st. yarmouith, MOL 02675 � e7E?�`' �� go �t7 ARV ' H, 0J , P4 L o s. �DA'l',F,'