HomeMy WebLinkAbout0117 GREAT MARSH ROAD - Health 117 Great Marsh Road, Centerville
_210- 128 002
-
i
f ;I
I
f
3
f
Slll_ �__- iSc�cLOk%
llll
UPC 17534
No.2-11553COR
kA8TIN08,UN
No. `7
7 (9 �7 a Fee tx"�
THE COMMONWEALTH OF MASSACHUSETTS Entered in computer:
Yes
PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS
01ppYication for Migaaf *pttem Construction Permit
Application for a Permit to Construct( /)Repair( )Upgrade( )Abandon( ) ❑Complete System ❑Individual Components
Location Address or Lot No. a/0 /oZ T- ,? Owner' Name,Address Tel.No.
dE arty lea, �✓esE•fa Y-"f0 .---
Assessor's Map/Parcel (1,e ✓_, -7-7/ - 61" 3
Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No.
Type of Building:
Dwelling No.of Bedrooms Lot Size 11 sq. ft. Garbage Grinder( )
Other Type of Building No.of Persons Showers( ) Cafeteria( )
Other Fixtures
Design Flow ` A10 gallons per day. Calculated daily flow 9 7-6 gallons.
Plan Date Number of sheets Revision Date
Title
Size of Septic Tank Type of S.A.S.
Description of Soil
Nature of Repairs or Alterations(Answer when applicable)
Date last inspected:
Agreement:
The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi-
cate of Compliance has been issued his B oaro o Healt '
Signed F Date F6 ' 2 I J 7
Application Approved by Date
Application Disapproved for the foll wing reasons
Permit No. T7 l Date Issued
-�.. - . T.. ��mac.; !ri.... -,sr-..�,.tv,,tM..�",.._% _•' .T"
N — C� 'S«po Fee_IncZ
THE COMMONWEALTH i OF MASSACHUSETTS Entered in computer.o
Yes
PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS
Zip lfication for Migogaf *pztem Cougtr rtion Permit
Application for a Permit to Construct( Repair( )Upgrade( )Abandon( ) ❑Complete System ❑,Individual Components
Location Address or Lot No. /(5 /a y - ,Z Owner' Name,Address ato Tel.No.
Assessor's Map/Parcel /t 7 C•`d!F /�1 !
!/ (-s ✓, IG -7-t r G e d 3
Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No.
n
�jprf 0164 % 1.. u'r SF. AAr (� 7
-7-71 - 539 � 7icc7 - lN5 `4t'
Type of Building:
Dwelling t No.of Bedrooms Lot Size '13T 3 sq.ft. Garbage Grinder( )
Other Type of Building No.of Persons Showers Cafeteria
YP g ( ) ( )
Other Fixtures
Design Flow '`I qo gallons per day. Calculated daily flow G gallons.
Plan Date /a���r 57 Number of sheets Revision Date
Title
Size of Septic Tank Type of S.A.S.
s
Description of Soil
Nature of Repairs or Alterations(Answer when applicable)
t
Date last inspected:
Agreement: r
The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi-
cate of Compliance has been issued this Board-o 'Health.
t Signed 6' c o �G Date 16 2 �►7
Application Approved by Date 1 I — 1 2-- 9-7
Application Disapproved for the foll wing reasons r
r
Permit No. / 7 - \Ko 1 Date Issued
THE COMMONWEALTH OF MASSACHUSETTS
BARNSTABLE, MASSACHUSETTS
(Certificate of (Compliance
THIS IS TO CERTIFY, that the On-site Sewage Disposal System Constructed( �)Repaired( )Upgraded( )
Abandoned( )by e K.,`t-c 11• r C o A,r ra v c T L U,,,
at /r'1 C, t Hf a r r t K o a d (' ./. /G has been constructed in accordance
with the provisions of Title 5 and the for Disposal System Construction Permit No.2 7- 1 dated
Installer Designer 6 G rN N C A,'(
The issuance of this permit shall Wit be construed as a guarantee that the syst f ill fu�nsti. as/designed.
Date (�^ Z -7—7 ; Inspector��.�.w �/
---------------------------------------
�7_ t' .-
No. � Fee
THE COMMONWEALTH OF MASSACHUSETTS
PUBLIC HEALTH DIVISION - BARNSTABLE, MASSACHUSETTS t
Mt!5pozar *pztem Construction Permit
Permission is hereby granted to Construct( Repair( )Upgrade( )Abandon( )
System located at /1 �r a r s I �� e �! 11 , I4
and as described in the above Application for Disposal System Construction Permit. The applicant recognizes his/her duty to
comply with Title 5 and the following local provisions or special conditions.
Provided:Construction must becompleted within three years of the date of this e t. cq
Date: Z z �/ Approved by r �/
LLTOWN OF BARNSTABLE
<+;:: :LOCATION ? d4 I60k (� SEWAGE #.>:.97`6 S
VII.LAGE Jt A SESSOR'S & LOT VO-i '0 cep L
INSTALLER'S NAME&PHONE NO. g a
SEPTIC TANK CAPACITY / DD &A
:LEACHING FACILITY: (type) S (size)
..' .NQ.OF BEDROOMS
B -ILDER R OWNER �(��
.:`::PERMTIDATE: 11—( z-`�� COMPLIANCE DATE: Z'ZZ-T7
..::Separation Distance Between the:
Maximum Adjusted Groundwater Table and Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
::on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist
within 300 feet of leaching facility) Feet
Furnished by
X.
J}'� - 13 �
as'
A 3 - 3b"
3
a3'
, . . 3
r ..
\-�t:b 0
ids ® 1 '�S Z�1
2�
V�
Commonwealth of Mossachusetts ,John Grad
Executive Office of ErMronmeMcil Affairs D.E.P. Title V Septic I1>spector
Department of P.O. Box 2119
Environmental Protection Teaticket, MA 02536
(508) 564-6813
; o
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A N
CERTIFICATION ~ Mq fftb
R Y ® Cif
Property address: 117 Great Marsh Rd.Centerville Address of Owner: �t �
Date of Inspection:u11197 (If different) or 199�
Name of Inspector:John Gracl Porkka
Company Name,Address and Telephone Number: 1
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate
and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and
maintenance of on-site sewage disposal systems. The system:
_ Passes This inspection is based on criteria defined in Title V
Conditionally Passes code 310 CMR 15.303.My findings are of how the system is
Needs F he Evaluation 8 the Local Approving Authority performing at the time of the Inspection.My Inspection does
Y PP 9 tY not Imply any warranty or guarantee of the longevity of the
X Fails septic system and any of its components useful life.
Inspector's Signature: IA.:
Date: 314197
The System Inspector shall submit a copy of this inspection report to the Approving Authority within thirty(30)days of completing this
inspections. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit
the report to the appropriate regional office of the Department of Environmental Protection.
The original should be sent to the system owner and copies sent to the buyer, if applicable and the approving authority.
INSPECTION SUMMARY:
Check A, B,C, or D:
A] SYSTEM PASSES:
_I have not found any information which indicates that the system violates any of the failure criteria
defined as in 310 CMR 15.303. Any failure criteria not evaluated are indicated below.
B] SYSTEM CONDITIONALLY PASSES:
One or more system components need to be replaced or repaired. The system,upon completion
of the replacement or repair,passes inspection.
Indicate yes,no,or not determined(Y, N,or ND). Describe basis of determination in all instances. If "not determined",explain why not.)
The septic tank is metal,cracked,structurally unsound,shows substantial infiltration or exfiitration,or tank failure is
imminent. The system will pass inspection if the existing septic tank is replaced with a conforming septic tank as approved
by the Board of Health.
(revised 11115195)
One Winter Street • Boston,Massachusetts 02108 • FAX(617)5564049 • Telephone(617)292-5500
1
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2111197
Sewage backup or breakout or high static water level observed in the distribution box is due to a broken,
settled or uneven distribution box. The system will pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
distribution box is leveled or replaced
The system required pumping more than four times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
C) FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH:
Conditions exist which require further evaluation by the Board of Health in order to determine if the
system is failing to protect the public health, safety and the environment.
1} SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES THAT THE SYSTEM IS
NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND
SAFETY AND THE ENVIRONMENT:
Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER, IF APPROPRIATE)DETERMINES
THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECT THE PUBLIC HEALTH AND SAFETY AND THE
ENVIRONMENT:
The system has a septic tank and soil absorption system and is within 100 feet to a
surface of water supply or tributary to a surface water supply.
The system has a septic tank and soil absorption system and is within a Zone 1 of a public water
supply well.
The system has a septic tank and soil absorption system and is within 50 feet of a private water
supply well.
The system has a septic tank and soil absorption system and is less than 100 feet but 50 feet or more from a private
water supply well, unless a well water analysis for coliform bacteria volatile organic compounds indicates that the well is
free from pollution for that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal or less than 5 ppm.
3) OTHER
DJ SYSTEM FAILS:
X I have determined that the system violates one or more of the following failure criteria as defined in
310 CMR 15.303. The basis for this determination is identified below. The Board of Health should be
contacted to determine what will be necessary to correct the failure.
Backup of sewage in facility or system component due to an overloaded or clogged SAS or
cesspool.
Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged
cesspool.
SAS is in hydraulic failure.
(revised 11115195)
2
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 117(;real Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2111197
D] SYSTEM FAILS(continued)
Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow.
Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).
Numbers of times pumped
Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation.
Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply.
Any portion of a cesspool or privy is within a Zone 1 of a public well.
Any portion of a cesspool or privy is within 50 feet of a private water supply well.
_ Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no
acceptable water quality analysis. If the well has been analyzed to be acceptable, attach copy of well water analysis for
coliform bacteria,volatile organic compounds,ammonia nitrogen and nitrate nitrogen.
E] LARGE SYSTEM FAILS:
The following criteria apply to large systems in addition to the criteria:
The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to
public health and safety and the environment because one or more of the following conditions exist:
the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area (IWPA)or a mapped Zone II of a
public water supply well)
The owner or operator of any such system shall bring the system and facility into full compliance with the groundwater treatment program
requirements of 314 CMR 5.00 and 6.00. Please consult the local regional office of the Department for further information.
(revised 11115195)
3 �
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECLIST
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:ZH1197
Check if the following have been done:
X Pumping information was requested of the owner,occupant, and Board of Health.
X None of the system components have been pumped for at least two weeks and the and the system has been receiving normal
flow rates during that period. Large volumes of water have not been introduced into the system recently or as part of this
inspection.
n1aAs built plans have been obtained and examined. Note if they are not available with N/A.
X The facility or dwelling was inspected for signs of sewage back-up.
X The system does not receive non-sanitary or industrial waste flow.
X The site was inspected for signs of breakout.
X All system components,excluding the Soil Absorption System,have been located on the site.
X The septic tank manholes were uncovered,opened, and the Interior of the septic tank was inspected
for condition of baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge, depth of scum.
X The size and location of the Soil Absorption System on the site has been determined based on existing information or
approximated by non-intrusive methods.
X The facility owner(and occupants,if different from owner)were provided with information on the proper maintenance of Sub-
Surface Disposal System.
(revised 11115195)
4
r
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2111197
FLOW CONDITIONS
RESIDENTIAL:
Design flow: U gallons
Number of bedrooms: 1
Number of current residents: 9
Garbage grinder(yes or no): No
Laundry connected to system(yes or no): Yes
Seasonal use(yes or no): No
Water meter readings,if available: n1a
Last date of occupancy: 2 years ago
COMMERCIAL/INDUSTRIAL:
Type of establishment: nla
Design flow:9 gallons/day
Grease trap present:(yes or no) No
Industrial Waste Holding Tank present: (yes or no) No
Non-sanitary waste discharged to the Title 5 system: (yes or no) No
Water meter readings, if available: n1a
Last date of occupancy: n1a
OTHER: (Describe) nla
Last date of occupancy:
GENERAL INFORMATION
PUMPING RECORDS and source of information:
System has not been pumped In the last two years.
System pumped as part of inspection:(yes or no)No
If yes,volume pumped: gallons
Reason for pumping: nla
TYPE OF SYSTEM
Septic tank/distribution box/soil absorptions system
x Single cesspool
Overflow cesspool
Privy
Shared system(yes or no) ( if yes,attach previous inspection records,if any)
Other(explain)
APPROXIMATE AGE of all components,date installed(if known)and source information:
1950
Sewage odors detected when arriving at the site:(yes or no) No
(revised 11115195)
5
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2I1197
SEPTIC TANK:
(locate on site plan)
Depth below grade: n1a
Material of construction:X concreate_metal_FRP_other(explain)
Dimensions: n1a
Sludge depth:n1a
Distance from top of sludge to bottom of outlet tee or baffle: n1a
Scum thickness:n1a
Distance from top of scum to top of outlet tee or baffle:nla
Distance form bottom of scum to bottom of outlet tee or baffle: n1a
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,
evidence of leakage,etc.)
n1a
GREASE TRAP:
(locate on site plan)
Depth below grade: rda
Material of construction: _concrete_metal_FRP_other(explain)
Dimensions: n/a
Scum thickness:n1a
Distance from top of scum to top of outlet tee or baffle:n1a
Distance from bottom of scum to bottom of outlet tee or baffle: n1a
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles,depth of liquid level in relation to outlet invert,structural integrity,
evidence of leakage,etc.)
n1a
(revised 11/15195)
a
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2111197
TIGHT OR HOLDING TANK:
(locate on site plan)
Depth below grade: n1a
Material of con struction:_concrete_metal_FRP_other(explain)
Dimensions: n1a
Capacity: n1a gallons
Design flow: n1a gallons/day
Alarm level: nla
Comments:
(condition of inlet tee,condition of alarm and float switches, etc.)
nla
DISTRIBUTION BOX:
(locate on site plan)
Depth of liquid level above outlet invert: n1a
Comments:
(note if level and distribution is equal, evidence of solids carryover, evidence of leakage into or out of box etc.)
n1a
PUMP CHAMBER:
(locate on site plan)
Pumps in working order:(yes or no)
Comments:
(note condition of pump chamber,condition of pumps and appurtenances,etc.)
n1a
(revised 11115195)
7
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2111197
SOIL ABSORPTION SYSTEM(SAS):x
(locate on site plan,if possible;excavation not required,but may be approximated by non-intrusive methods)
If not determined to be present,explain:
rVa
Type:
leaching pits, number: nla
leaching chambers,number:n1a
leaching galleries,number: n1a
leaching trenches,number, length: nla
leaching fields,number,dimensions:n1a
overflow cesspool,number:n1a
Comments:(note condition of soil, signs of hydraulic failure,level of ponding, condition of vegetation, etc.)
n/a
CESSPOOLS:x
(locate on site plan)
Number and configuration: one
Depth-top of liquid to inlet invert: empty
Depth of solids layer: n1a
Depth of scum layer: n1a
Dimensions of cesspool: 4•x5'
Materials of construction: block
Indication of groundwater: n1a
inflow(cesspool must be pumped as part of inspection)
n1a
Comments:(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation, etc.)
Cesspool is structurally usound.It is rootbound.
PRIVY:_
(locate on site plan)
Materials of construction: n/a Dimensions: n1a
Depth of solids: nla
Comments:(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.)
n1a
(revised 11/15195)
8
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 117 Great Marsh Rd.Centerville
Owner: Porkka
Date of Inspection:2111197
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent references landmarks or benchmarks
locate all wells within 100'
DEPTH TO GROUNDWATER
Depth to groundwater:12 feet
method of determination or approximation:
USGS Maps and Charts
(revised 11/15/95)
' 9
TOWN OF BARNSTABLE
,?Ifs
LOCATION il�j ��� a Z �� SEWAGE # 97-0 5
VILLAG A SESSOR'S MAP & LOT Z10-4L9--ca z
INSTALLER'S NAME&PHONE NO. �) ecM— S 5 L
SEPTIC TANK CAPACITY Oa &A I
LEACHING FACILITY: (type) ^ (5 (size)
NO.OF BEDROOMS 1
BUILDER R OWNER
PERMITDATE: I I—( Z ?� COMPLIANCE DATE:
Separation Distance Between the:
Maximum Adjusted Groundwater Table and Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist
within 300 feet of leaching facility) Feet
Furnished by
j_,
�i --- �� ;
�a - ��
�-� - ��'
�� � ��
-------------------
i
SEPTIC PROFILE TEST HOLE LOus
T.O.F. AT EL.
ACCESS COVER TO WITHIN ir OF FIN. GRADE (NCYT M swE)
ACCESS COVER (WATERTIGHT) TO
ENGINEER: � ' � �/.a.�a ► r� .�� , .--2 r,`-.... �
,�� MINIMUM .75 OF COVER OVER PRECAST WITHIN �' OF FIN. GRADE i h
2% SLOPE REQUIRED OVER SYSTEM WITNESS:
RUN PIPE LEVEL DATE: = I % 'q ^�� `
FOR FIRST 2' 2+ DOUBLE WASHED PEASTONE - Guy". /��'�'`�
PROPOSED Isom �� 3 MAX. PERC. RATE - ° ✓ 1
GALLON SEPTIC <
3 37•S� 7y CLASS'� SOILS P# 4-
TANK (H- 10 ) GAS 3`7 2?,
» .: ..
BAFFLE 3 .3 �' o po�� ✓ r
o 0 0 0 0 0 0 0 o
(._._X SLOPE) 8` CRUSHED STONE OR MECHANICAL ' 0 0 0 0 0 0 0 0 0 ELEV. ELEV.
COMPACTION. (15.221 (21) y
DEPTH OF FLOW - J�` 1
) Q ifi /
TEE SIZES: ( % SLOPE) (�X SLOPE) �� o ,h y� Q �.� Q"
INLET DEPTH tom" \1. ,Nti hP � � a(o ..
ounEr DEPTH 31e TO 1 1/2" DOUBLE WASHED STONE � �,Y ��� LOCATION MAP SCALE 1"
— �
L
FOUNDATION 10 r SEPTIC TANK 1 D' BOX 1 `( --- - -�•.---- .• ---
' LEACHING � �'•`'
FArtI mr �"� -7 .L- . ASSESSORS MAP �-I--7 PARCEL I 1<3 w
C,�
ZONING DISTRICT: RC
7 �E- z �- YARD SETBACKS:
o �-
\ �Nc�� FRONT =
SIDE
REAR = 1
PLAN REF. - Sd A-) yc�
0 �
FLOOD ZONE:
�r•1��/�rJ �� 3 . / � -
� E _
1
i
NOTES:
• `
✓� vi /�0% r�4 / Ho I,.Ikw "L
�4� EPTIC DESIGN: (GARBAGE DISPOSER IS 1 . DATUM IS
FLOW: BEDROOMS ( '�2 GPD) ` +J GPD 2. MUNICIPAL WATER" IS r;✓/5-i ►-L`t�L G
ISE A � GPD DESIGN FLOW
3. MINIMUM PIPE PITCH TO BE 1/8 PER FOOT.
8 z,&3TIC TANK: ,�. , GPD (_ '�" ) _ � 4. DESIGN LOADING FOR ALL .PRECAST UNITS TO BE AASHO H- to .
5. PIPE JOINTS TO BE MADE WATERTIGHT.
y r Q OSE A s2 GALLON SEPTIC TANK
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS.
LEACHING: l r ENVIRONMENTAL CODE TITLE V.
��� r �� /' ^ SIDES: z ��' ��' J l.7`� 6�°o 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE
V� % f ° s A --� USED FOR LOT LINE STAKING.
130TTOM ---r- 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-47 PVC.
/ 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITH
1
• ,� °`�,.,;�' J,� �`� c +;�' c ,' �t' % , �,f' �r?` 'OTAL: � I ci S.F. -�-�1� .GPD INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED
f ED
_ ' � r,•�a �h E (Q "�1D,�l�I Z.-�Q-, I�r'� ��'r'�is�'r' f'1,,,G�
jr�
�� ` __. r ,--�--F FROM BOARD OF HEALTH.
r r✓ '� °�I� hTdrG ' �t ' "' 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
ff' ram; LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR
' TO COMMENCEMENT OF WORK.
i
LEG EN D
SITE AND SEWAGE PLAN
j , 100.0 PROPOSED SPOT ELEVATION
OF � -
I 100x0 EXISTING SPOT ELEVATION t I ,J, ��A` �. 1 r 'CIA
IN THE TOWN OF:
ri-0-01 -o PROPOSED CONTOUR ,
EXISTING CONTOUR
PREPARED FOR:
{if11 Ar 6✓ 3�'F. A.. ' j N Y'' g: :� ��.. t ,�,a. A"
1
^ BOARD OF REALTB
MA
' �r !�PPROV]sD DATE SCALE: I{ � DATE
aR 506-302-4841
fmt 5W 302-000
P A +
' down nape engineering, inc. � AR NE
CIVIL ENGINEERSClvM_ i
LAND SURVEYORSr\
JOB �?- '3 ca 939 main st. yarmouth, ma 02675 .L.
ARNE H. OJT, P. ., S. DATB
i