Loading...
HomeMy WebLinkAbout0014 BUTTERNUT CIRCLE !Ll '5u44ermL*A Csre- I�o. ) � � � ) . ) � � � � ] � ] ) . � ] � ) . 4 . \ § . \ � � . � �� } � �� � d . � � � � » . � . � � � . ( . ` \ �\ . � . x` \ � . � � � , ]\ � � w � � . � � � � � � ) � ) KIO. 152 1/3 YEL I i i ,i t, i TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map Oro Parcel le9l Application Health Division Date Issued Conservation Division Application Fee Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board Historic - OKH _ Preservation/ Hyannis Project Street Address .�un"en-y e, �rel Village Coeur // Owner (/eslU grain Address 0,955 i Telephone �1'2P/- 6019-0.S9,3 Permit Request INs7AI-L SCILVR ELE67 < PAal'1S a1J Roof OF FX1 'r2X6 ROJAS rb BE' .1M7XRCdA A;EC72,V WirNNOM� LE'CTR�CRG 59572"M. �,zskW Square feet: 1 st floor: existing AIA proposed n/A 2nd floor: existing N.4 proposed A0 Total new /? Zoning District RP Flood Plain Groundwater Overlay ��I o Project Valuation M,egd Construction Type 4ZZkrq A( Lot Size .j o e NG Grandfathered: ❑Yes ❑ No If yes, attach su porting docume tation. Dwelling Type: Single Family Two Family. ❑ Multi-Family(# units) .Ya .Age of Existing Structure 3o yrs Historic House: ❑Yes XNo On Old King's yHighway "-b Yes; No Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other "A `" m Basement Finished Area (sq.ft.) MA Basement Unfinished Area (sq.ft) nrA Number of Baths: Full: existing AjA new Half: existing NA new Number of Bedrooms: AIA existing _new Total Room Count (not including baths): existing AIA new First Floor Room Count AtR Heat Type and Fuel: ❑ GasA0❑ Oil ❑ Electric ❑ Other Central Air: ❑YesA#90 No Fireplaces: Existing t_New Existing wood/coal stove: ❑Y No Detached garage: ❑ existW ❑ new size_Pool: ❑ existing/Knew size _ Barn: ❑ exiV94 ❑ new size_ Attached garage: ❑ existin&//J new size _Shed: ❑ existing new size _ Other: / 1r4 Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes XNo If yes, site plan review # Current Use P„ z,lu Proposed Use sAMg- APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name 56za.r (�7, 6 Telephone Number �;8l- #?F x 6741?9 Address O�'aro �Anlc �r�u �o2s/d License # ('5/0766 3 ' Home Improvement Contractor# Email mmli em Lv Worker's Compensation # ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO zL c✓tc�pS��r an v ,SD�r d 4e e4)82 . >60 C;O2:onr2XE Pzek Drlde #o7e?SID, PdW rv.Et 14-,w ��3✓r9 SIGNATURE - DATE �(4 1 94 FOR,OFFICIAL USE ONLY APPLICATION# DATE ISSUED 1 MAP/PARCEL N0. ADDRESS + VILLAGE. 'f OWNER ' DATE OF INSPECTION: FOUNDATION FRAME INSULATION - FIREPLACE ELECTRICAL: ROUGH FINAL - PLUMBING: ROUGH FINAL GAS: ROUGH- FINAL FINAL BUILDING DATE CLOSED OUT ASSOCIATION.PLAN.N.O. f - The Commonwealth of Massachusetts Department of Industrial Accidents Orice of Investigations t I Congress Street,Suite 100 r` Boston,MA 02114-2017 www mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Leeibly Name(Business/Organization/Individual): 50l8rCIty Corporation_ Address: 3055 Clearview Way City/State/Zip: San Mateo/CA/94402 Phone#: 650-963-5100 Are you an employer?Check the appropriate box: Type of project(required): 1.IN I am a employer with 3000 4. ❑ 1 am a general contractor and 1 employees(full and/or part-time).' have hired the sub-contractors 6. New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. ❑Demolition workingfor me in an capacity. employees and have workers' y p ty• = 9. ❑Building addition [No workers' comp. insurance comp. insurance. required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no Solar/PV employees. [No workers' 13.■0 Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ant an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Liberty Mutual Insurance Company Policy#or Self-ins. Lic.#: WA766DO66265023 Expiration Date: 09/01/2014 I j Job Site Address: All Locations City/State/Zip: Barnstable,MA Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of rJ1 that tii Information provided above Is true and correct. Signature: Date: 5/14/2014 Phone#: 9782152359 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ACC CERTIFICATE OF LIABILITY INSURANCE D08/21 ID013 08/21/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pol(cy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER 0726293 1-415-546-9300 co MNTeCYNA Brendan Quinlan Arthur J. Gallagher s Co. PHONE FAX Insurance Brokers of California, Inc., License #0726293 1AIC,No go, 415-536-4020 1_(AIc.No): 1255 Battery Street 8450 ADOREss: brendan quinlan@ajq.com San Francisco, CA 94111. INSURER(S)AFFORDING COVERAGE NAIC• INSURER A: LIBERTY 14UT FIRE INS CO 23035 INSURED INSURERS: LIBERTY INS CORP 42404 SolarCity Corporation INSURER C 3055•Clearviev Way INSURER 0: San Mateo , CA 94402 INSURERE• INSURERF. COVERAGES CERTIFICATE NUMBER: 35272277 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL S SR Im POLICY NUMBER POLICY EFF PMMIDDNYYYI OLICY EXP LIMITS LTRA GENERAL LIABILITY rB2661,066265053 09/01/1 09/02/14 EACH OCCURRENCE $ 1,000,000 X TO HEWED COMMERCIAL GENERAL LIABILITY PREMISES(Ea aeroo) $ 100,000 CLAIMS-MADE a OCCUR MED EXP one S 10,000 X Deductible: $25,000 PERSONAL&AOVINJURY $ 1,000,000 GENERAL AGGREGATE $2,000,000 GEML AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGO S 2,000,000 X I POLICY I I PRO- LOC 1 $ A AUTOMOBILE LIABILITY AS2 COMBINED SINGLE LIMIT Ea accidentl $1,000,000 ANY AUTO BODILY INJURY(Per person) S AUTOSALLOW NED SCHEDULED BODILY INJURY(Per ecciderd) S HIREOAUTOS AUTOS NO"WNED PRO PERTYDAMAGE $ X1AUTOS Per accident S UMBRELLA LIAS OCCUR EACH OCCURRENCE S EXCESS LIAe HCLAIMS-MADE _ AGGREGATE S DIED RETENTION S $ B WORKERS COMPENSATION WC7661066265033 (WI Retr ) 0g/Ol/1 09/01/14 X IwCR STATrU OTW AND EMPLOYERS'LIABILITY B ANY PROPRIETORIPARTNER/EXECUTIVE YIN WA766DO66265023 (Ded) 09/01/1 09/01/14 E.L EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N I A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE S 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT S 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Rema*s Sehodute,If more space Is required) Proof Of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Evidence of Insurance Only THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD satyasan 35272277 rtx��� Office of Consumer Affairs and Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION . Expiration: 3/812015 CRAIG ELLS ---- — 24 ST. MARTIN STREET BLD 2 UNIT 11 — —— ----- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. scA i e, ?OM"05:1> Address Renewal (_] Employment LI Lost Card 4'� a trice of Consumer Affairs&Business Regulation License or registration valid for individul use only ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation Registration: 168572 TYPr' 10 Park Plaza-Suite 5170 1}' Expiration: 3/8/2015 Supplement :ard Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS r 24 ST MARTIN STREET BLD 2UNI - "hLBOROUGH,MA 01752 Undersecretary Not v lid without signature y Massachusetts •Department of Public Safety Board of Building Regulations and Standards (lonailli t1Un sulwo Isfir a �cense CS-107663 8 , CRAIG ELLS � 206 BAKER STREET INCA � Keene NH 03431:. ; i ji utr��i hS ti+t!i tt�r 08/29/2017 I L9L ., touOfce � ,mesN/g4to 10 Park Plaza. - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION :_ Expiration: 3/8/2015 M1 ALEC MEYERS ,` 24 ST. MARTIN STREET BLD 2 UNIT 11 - MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. SCA i Co 20M-Mli � Address [] Renewal F] Employment 0 Lost Card F���C TI niriveoiunea�/�c�'C_?lla.itrrc�ri;e/%i f iice of Consumer Affairs&Business Regulation License or registration valid for individul use only ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation egistration: 16672 Type: 10 Park Plaza-Suite 5170 Expiration:'.3/8/2015 , Supplement Card Boston,MA 02116 SOLARCITY CORPORATION ALEC MEYERS ' 24 ST MARTIN STREET:BLD,'2_UNI IWi-BOROUGH,MA 01752 Undersecretary Not Afidit=outsl/nAatluu�re �� �opa` �� �µ OF',MA Version#34.3 SolarClt y .�o� AMIR �G MASSOUMI 3056 Clearview Way,San Mateo, CA 94402 V CIVIL y (888)-SOL-CITY (765-2489) I www.solarcity.com N0.5 555 A May 7,2014 Project/Job#026292 `� G t RE: CERTIFICATION LETTER r Project: Straub Residence Digitally signed by Amir Massoumi 14 Butternut Cir Barnstable, MA 02635 Date: 2014.05.07 17:29:10 -071001 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code,8th Edition,ASCE 7-05,and 2005 NDS - Risk Category= II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf -MP1: Roof DL= 10.5 psf, Roof LL/SL= 20 psf(Non-PV Areas), Roof LL/SL= 12.3 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss =0.19312 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the structural roof framing has been reviewed for loading from the PV assembly on the roof.The structural review only applies to the section(s)of the roof that directly supports the PV system and its supporting elements.After this i review it was determined that the existing structure is adequate to carry the PV system loading. I certify that the structural roof framing and the new attachments that directly support the gravity loading from PV modules have been reviewed and determined to meet or exceed requirements of the MA Res.Code,8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Amir Massoumi, P.E. Civil Engineer Direct: 650.963.5611 email: amassoumi@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY P(650)638-1029 solarcity.com AZ RCC 243771.CA CSLB B39104.C0 Bt:9041.C1 HM OS3277B,DC HIC 71101466,DC HS 71101486,HI CT•29770,MA HIC 168512,MD MHIC 126946.N,1 MH1t616II609. CA CCB 18tt498,PA 077343,TX TDLA 27008,WA CCL:SOLARC'91907.C 2013 1;awGty.A!1,t3hto reaervc9. i . 05.07.2014 `�►l;So�arC i ty. SleekMountTM PV, System Version#34.3 ' Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project.Name., Straub Residence AHJ: Barnstable Job Number: 026292 Building Code: MA Res.Code, 8th Edition Customer_Name: Straub,Wesley Based On: IRC.2009•/_IBC_2009 Address: 14 Butternut Cir ASCE Code: ASCE 7-05 City/State: Barnstable, MA W Risk Category_ II Zip Code 02635 Upgrades Req'd? No Latitude/Longitude_ 41.646853 -70.434542_ Stamp Reqd? Yes SC Office: South Shore PV Designer: Nick Ozello Calculations: Humphrey Kariuki P.E. EOR: Amir Massoumi P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss =0.19312 < 0.4g and Seismic Design Category(SDQ = B < D 1 2-MILE VICINITY MAP Lovells Pond 28 • 28 4 5. iDqigi 14 Butternut Cir, Barnstable, MA 02635 Latitude:41.646853, Longitude:-70.434542,Exposure Category:C I STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1 Member Properties Summary MP1 Horizontal Member Spans Rafter Properties Overhang 0.74 ft Actual W 1.50" Roof System Properties Span 1 13.50 ft Actual D 7.25" i Number of Spans(w/o Overhang) 1 Span 2 Nominal ' Yes Roofing Material Comp Roof Span 3 A 10.88 in.A2 Number of Layers(Comp Only) 2 Layers San 4 S. 13.14 in.A3 Re-Roof to 1 Layer of Comp? No Span 5 I 47.63 in.A4 Plywood Sheathing Yes Total Span 14.24 ft TL Def'n Limit 120 Board Sheathing None PV 1 Start 1.75 ft Wood Species SPF Vaulted Ceiling No PV 1 End 12.75 ft Wood Grade #2 Rafter Slope 320 PV 2 Start Fb 875 psi Rafter Spacing 16 O.C. PV 2 End ry 135 psi Top Lat Bracing Full PV 3 Start E 1400000 Bot Lat Bracing At Supports PV 3 End Emin 510000 Member Loadina ary Roof Pitch 7/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.5 psf x 1.18 12.4 psf 12.4 psf PV Dead Load PV-DL 3.0 psf x 1.18 3.5 psf Roof Live Load RLL 20.0 psf x 0.85 17.0 psf Live/Snow Load LL/SL 30.0 psf x 0.67 1 x 0.41 20.0 psf 12.3 psf Total Load TL 32.4 psf 28.2 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(C0(Is)py; Ce=Cr=Is=1.0; Member Desi n Summary(per NDS Load Combinations CD CL + CL - CF Cr D 0.9 1.00 0.45 1.2 1.15 D+(Lr or S)(Governs) 1.15 1.00 0.45 1.2 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 34 psi 0.7 ft. 155 psi 0.22 Bending + Stress 784 psi 7.5 ft. 1389 psi 0.56 Governs Bending - Stress -4 psi 0.7 ft. -627 psi 0.01 Total Load Deflection 0.42 in. 7.5 ft. L/383 0.31 CALCULATION OF_DESIG_N WIND LOADS - MP1 Mountin Plane Information Roofing Material Comp Roof PV System Type SolarCity_SleekMountT"' Spanning Vents No Standoff Attachment Hardware ComEkjQqaLjYR@ C Roof Slope 320 Rafter Spacing 16"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA y Tile Reveal Tile Roofs Only_ NA Tile Attachment System _Tile Roofs Only NA Standin Seam Spacing SM Seam Onl NA Wind Design Criteria Wind Design Code ASCE,7-05 Wind Design Method Partially/Fully Enclosed Method_ Basic Wind Speed V 110 mph T Fig. 64 . Exposure Category C Section 6.5`6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Krty_� 1.00 Section 6.5.7 Wind Directionality Factor Ka 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure P p =qh(GC ) Equation 6-22 Wind Pressure U -21.3 psf Wind Pressure Down 1 19.6 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever _ __Landscape_ _ _ _ 24" _ NA Standoff Configuration Landscape Staggered Max Standoff Tributary"Area Trib 17 sf PV Assembly Dead Load W-PV 3 psf NetNet Wind"Uplift at Standoff T-actual_ -342 Ibs Uplift Capacity of Standoff T-allow 500 Ibs i Standoff Demand/Capacity DCR 68.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait - 19" NA Standoff Configuration Portrait Staggered Max Standoff Tributary_Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -427 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Staneoff Demand/CapacitV DCR 85.4% os�J p�9,SolarC�ty. Solarleas6 SUMMARY Wesley Straub 14 Butternut Cir MA MA HIC 168572/MA Lic. 14 Butternut Cir Barnstable, MA 02635 MR-1136 Barnstable, MA 02635 Estimated Solar Energy Production First Year Annual Production: 6,157 kWh Initial Term Total Production: 117,472 kWh Payment Terms Amount Due at Contract Signing: $0 Amount Due when Installation Begins: $0.00 Amount Due following Bldg. Inspection: $0.00 Estimated Price per kWh First Year: $0.1727 Annual Increase: 0.0 % First Year Monthly SolarCity Bill: $88.60 Lease Term 20 Years SolarCity's Promises to You: Your Prepayment and Transfer Choices During the Term: • SolarCity will insure, maintain, and repair the System o If you move, you may transfer this agreement to the (including the inverter) at no additional cost to you as purchaser of your Home, as specified in the agreement. specified in the agreement. a If you move, you may prepay the remaining payments • SolarCity will provide 24/7 web-enabled monitoring at (if any)at a discount. no additional cost to you, as specified in the agreement. • SolarCity will provide a money-back production Your Choices at the End of the Initial Term: guarantee, as specified in the agreement. . SolarCity will remove the System at no additional cost o SolarCity will warranty your roof against leaks and to you. restore your roof at the end of the agreement as • You can upgrade to a new System with the latest solar specified in the agreement. technology under a new contract. • The pricing in this Lease is valid for 30 days after • You may renew your agreement for up to ten (10) 4123/2014. If you don't sign this Lease and return it years in two(2) five(5)year increments. to us on or prior to 30 days after 4/23/2014, SolarCity • Otherwise, the agreement will automatically renew for an additional one(1)year term at 10% less than the reserves the right to reject this Lease unless you agree then-current average rate charged by your local utility. to.our then current pricing. 22. PUBLICITY I have read this Lease and the Exhibits in their entirety and I acknowledge that I have received a complete copy of this SolarCity will not publicly use or display any images of Lease. the System unless you initial the space below. If you initial the space below, you give SolarCity permission to take pictures of the System as installed on your , Customer's N me: Wes y Strau Home to show to other customers or display on our website. Ho o r' Signature: T _} Date: -- 23. NOTICE OF RIGHT TO CANCEL YOU MAY CANCEL THIS LEASE AT ANY TIME PRIOR Customer's Name: TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER _ THE DATE YOU SIGN THIS LEASE. SEE EXHIBIT 1, Signature: THE ATTACHED NOTICE OF CANCELLATION FORM, FOR AN EXPLANATION OF THIS RIGHT. Date: 24. ADDITIONAL RIGHTS TO CANCEL IN ADDITION TO ANY RIGHTS YOU MAY HAVE TOr5olarCity. CANCEL THIS LEASE UNDER SECTIONS 6 AND 23, YOU MAY ALSO CANCEL THIS LEASE AT NO.COST . SolarLease AT ANY TIME PRIOR TO 5 P.M. OF THE 141" CALENDAR DAY AFTER YOU SIGN THIS LEASE. SOLARCITY APPROVE® 25. Pricing The pricing in this Lease is valid for 30 days after 4/23/2014. If you don't sign this Lease and return it Signature: kyNOcN RM e.F.0 tows on or prior to 30 days after 4/23/2014, SolarCity reserves the right to reject this Lease unless you agree SolarLease to our then current pricing. :� SolarCity. Date: 4/23/2014 ti SolarCity OWNER AUTHORIZATION Job ID: Location: I ��T7�r�1 v�" Cie- 81%ro s4e 11A P✓y` as Owner of the subject property it hereby authorize SolarCity Corp—HIC 168572/ MA Lic 1136 MR to act on my behalf, in all matters relative to work authorized by this building permit application and sign Rd contract. QlY Signature of O er: Date: i 1i-ii is«ttiri�Juv c•aii;lili 2 LIr a 11 U9sriF;str.0 ai,f.9A jai.?:_' i ? i'5M l;:i TY I':'`..: * 4;: -`?. 18 SOLRRCITY.COM A1:.W.i:34•':',W,MHIi I_"%35.HI1' (WI 8H 4'4 F;•:.:?'L:.,i%r1t, 7<.-S3.I:4 f.OLiS!:.'••Ii4i! �QQ!J??/I92Q�. 2 ��� 1•CX �l?�LG' , •3• a' umer A a(rs"d Business ie uen Office of Cons g 10 Park Plaza - Suite 5170 =` Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card Expiration: 3/8/2015 SOLARCITY CORPORATION' ALEC MEYERS - - - - 24 ST. MARTIN STREET BLD 2 UNIT 19 -- - MARLBOROUGH, MA 01752 - Update Address and return card.Mark reason for change. Address ❑ Renewal ❑ Employment Lost Card SCA 1 b 20M•05/11 ��e`l!nv�ai��u�uura�/�c!�(%.%•r!aurrc�iidrl/,J j office of Consumer Affairs&Business Regulation License or registration valid for individul use only EROVEMENT CONTRACTOR M MP before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation egistration; 1685'72.VExp'ratiType: 10 Park Plaza-Suite 5170 ion::..,3/8/2015 Supplement Card Boston,MA 02116 SOLARCITY CORPORATION. ALEC MEYERS 24 ST MARTIN STREET4L 2UNl �— &AkLBOROUGH,MA 01752 Undersecretary Not lid without 16tur'e� i TOWN OF BAR:NSTABLE Permit No. 25 --�p . — _ Building Inspector ...� ,.. Cash � ----------------- qp ,e,a X OCCUPANCY- PERMIT. . _Bond Issued to Theo Construction CO. -Address T,.�. as 1 n fti-prniii- ("irn1P. l"oTuit Wiring Inspector � � r InspectionTdat.e ` A Plumbing InspectAr�t" Inspection date Y_ Gas Inspector qrn �� P �/A Inspection date 3duf 84 Engineering Department Inspection date .� .� . d - - Board of Health r Inspection date <Y? THIS PERMIT WILL NOT BE VALID, AND-THE BUILDING SHALL NOT BE OCCUPIED UNTIL SIGNED BY THE BUILDING INSPECTOR UPON SATISFACTORY COMPLIANCE WITH TOWN REQUIREMENTS AND IN ACCORDANCE WITH SECTION 119.0 OF THE MASSACHUSETTS STATE BUILDING CODE. Buildin-V&pector r FROM TOWN OF BARNSTABLE ~-R ••�- -•-- BUILDING DEPARTMENT ' fit.,�f, c7'ancls � ne r� S67 MAIN STREET HYANNIS, MA 0�2W1 «,..w._..............r,._we,-. Phone: 775-1120 L SUBJECT: FOLO HERE DATE Auguft 1, 1984 MESSAGE Wcrk has been cc=c der Permit #25880 (Ztm Ccnstnactioan Co.) , Please release Bond. SIGNED 4k& Z // / S/ ! DATE / r REPLY SIGNED N87-RMI RECIPIENT: RETAIN WHITE COPY,RETURN PINK COPY PRINTED IN U.S.A. SENDER: SNAP OUT YELLOW COPY ONLY.SEND WHITE AND PINK COPIES WITH CARBON INTACT. DD .20 760 ' C -P O Ar N �,o t♦O'` f a C ! , ` 0 IN o l/A ,oz ,iws.:;z P,/ a .. � ca LP o CP 7 M i (f) Z HEREBY C ERT t F Y T HAT TW 5 FO V N QAT I•0 N 15 LOCATED O'N.TYM LOT A5 SNOWN T THIS PLO < PLAN NO T OT MAQE Ffj1A AND CONFORMED -To THE-TOW N OF CD' AN WSTRUMEM 6URVEXANo I$ MVi-ME VSE '5AfV4-5TaBLrc Z014ING REGU.LATION'S REGARO►tAG r OF THE 6MAY, OWLY, -QNPEM NO CIRCUM- N rn n ' 57AMCE5 RED FPSETS 6E USEO wQ C FROM ET Ll aN0 LOT. LANES tit,,,I,c �L HER365 ,. ._. ( �, �jT C N.S CT ED ? fl RT Z RAY two i5. s. f ASrseSsor's map sand lot number .........Y ..'......�P.l.... �� �'� � F TM E l Sewq.ge. Permit number ... J�. Z.&./.......1 � `='.jC SYSTEM °,3� "1�3 '�^: ' INSTALLED CAD IN f��� Z BARNSTABLE, i } TITLE f House number ............ ..�....�................................:....... WITH90 rasa TOWN -OF . BARN-STABLE BUILDING INSPECTOR APPLICATION FOR PERMIT TO ............Construct ................................................................................................................. TYPE OF CONSTRUCTION Wood Frame ..................................................................................................................................... :/ . ..... .e..................19...c&3 TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: 33 Butternut Circle , Cotuit, Ma. Location ....................................................................................................................................................................................... Proposed Use Residential ............................................................................................................................................................................. Zoning District RC ..............................Fire District .............Cotuit .......................................... .............................................................. Name of Owner Theo Construction Co. , Inc Address ....24 Great Pond Dr. , S. Yarmouth, Ma. Nameof Builder ...............�................................................Address ..................................................................................... Nameof Architect ..........N A................................................Address .................................................................................... Number of Rooms 5......................I.........................Foundation .... poured Concrete ............................................................. Exterior cedar shingle asphalt shingle ........................................................................Roofing .................................................................................... Floors plywood.....................................................Interior ......sheetrock ............. .................................................................. Heating TIT....... !s....I.... .......Plumbing ....1...1/.�...�'7at..S . ` Fireplace ...............OI72...........................................................Approximate Cost ....?5. .9-0.0................................................. Definitive Plan Approved by Planning Board __Sept. _ 21___ 19_ 73 . Area 2 1 od................. O Diagram of Lot and Building with Dimensions Fee ............ .... .......................... SUBJECT TO APPROVAL OF BOARD OF HEALTH (10 i I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name %. - � -! �! CONST. SUP. LIC. 016681 !.....� ............i�"' � _ ^ - . '�HEO CONSTRUCTION CO. , INC. � '--?- —2-5`r8,8 '--Permit for O—�... --- ~......... � Single Family... i � ----.��—�----.-*—��n�������----.. , Location ......l4... rnllt../��z 'le � ' Cotoit � ''-------------------------'. Owner .Theo..Coo��tr i �_ Type of Construction ...�������--------. .........................'.....................................................' Plot ............................ Lot ................................. � � . . � Permit Granted ..December 15,...................................... g 83 . - �Date of Inspection ____________lq �. . v ' � CompletedDate � � � ! PE RMNT REFUSED � | `---------------------. 19 ---.----------------------�� � --...--.~-.------.-----------� |' / . —~-----..—.—.~.—..---.--------..- , ' . ------------.----------....—`—.. � Approved ' ' . . � ................................................ lA � ' ----~----------^----------- ' . � '' -------~—' ' ` ^ . . �r l ^- _ rr Assessor's^ map rand lot number ......... ..' ../11.1.. •/� y�FTHE rot �f3 P. Sewage Permit number G 2 ....1%h..M.. � .ice. w`� ♦�................. PZ 13AUSTAMLE. • House number ............!. .... ............................................... y� MA86 po,1639. `00 'Ep YFY 6. TOWN OF BARNSTABLE BUILDING . INSPECTOR APPLICATION FOR PERMIT TO Construct ' TYPE OF CONSTRUCTION Wood F.aae ............................................m.......................................................:................................. . .�; .! .......,G..................19... TO THE INSPECTOR OF BUILDINGS: . The undersigned hereby applies for a permit according to the following information: ` 33 Butternut Circle, Cotuit, Ma,. Location~' ....................................................... ...................................... . Proposed Use Residential - Zoning District ........... C........................................................Fire District ..............COtUlt................................................ Theo Construction nc " 24' Great 'Pond Dr. S. Yarmouth Ma. Nameof Owner `....................Co. ,�.....!.....Address' ....................................................................................' Nameof Builder ............Same................................... ........Addre;s .............................................:.::.................................. Name of Architect VA ................................Address Number of Rooms 5................................................Foundation .•••••P our ed concrete .................. ? ............. ............................................... Exierior cedar shingle asphalt g ........................................................................Roofing ...............................shin...........le.......................................... Floors Plywood „,,,,,,,,Interior sheetrock .............. ....................................................... ............................................................... Heating. Ff4d...-...gaS ........ :, :..:Plumbing ::..:1 1/2 ;baths .............. . ............ ........... Fireplace ..:............one...........................................................Approximate Cost ....25 ,000................................................. i Definitive Plan Approved by Planning Board __Sept. 21--------19 _73 , Area Diagram of Lot and Building with Dimensions Fee ................................................ SUBJECT TO APPROVAL OF BOARD OF HEALTH J _ ' N ' I hereby agree to conform to all the Rules and Regulations of the Town.of Barnstable regarding the above construction. Name % � �,,• / . !/�i� .�, CONST. SUP. LIC. 016681 .. .. ,-_ . TIBEO CONSTRUCTION CO, , INC. A=40-101 - ' / ' ~/ ' 3�800 One Story ' Permit No -.---.. for --..,----��---. . . ' Sioole ]7amilv D�elli ' -----'"------'^-------.=---- - ^ L6cotion .....�mt...33x......l4...Bot not_Cii�ole ' ----.--.����g��.-------------- . . Owner -. ..Coo tioo�_C.��.�_. ` Type of Construchoh .]�����-----.---.. ` . � ------.-------------------. ` . Plot ----'----� �� ----��------ _ ' ` ~ ' Dec. 5 ' 83 ' Permit Granted ..-�--'�'--��----.lP ` . / �~ . Date of | ------------l9 ' . Dote Completed -----.----_—..l9 ' ` .�~~~.. REFUSED ----.. lV ' " . . -.. -----.i_-r��cr./ -..�-- -- ' . --. -- - ' ' . � ^�- . � ~- =���./ --{��� / ~----��'^^^° '\�- ~r-''*' -__ . � `------.--.--.-. ................................... . . | ' � -------.----.- /----.-~.-.-.--' 7 ^ � Approved.......... ...................................... lA ---'....---_-------.-..---.^--- ` ^ . -----......-.--.---------..-----. ' ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIORE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR L Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING OC ON CENTER HARDWARE. PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & STC STANDARD TESTING CONDITIONS 690.47. TYP TYPICAL nz o UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT _ VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT ` PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES Cut heetREttLach DIAGRAM ` GEN #168572 1. THIS SYSTEM IS GRID—INTERTIED VIA A • ELEC 1136 MR UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 8TH EDITION MODULE GROUNDING METHOD: ZEP SOLAR OF THE MA STATE BUILDING CODE. 5. ALL ELECTRICAL WORK SHALL COMPLY WITH REV BY DATE COMMENTS AHJ: Barnstable THE 2014 NATIONAL ELECTRIC CODE INCLUDING ` 2$" REV A NAME DATE COMMENTS MASSACHUSETTS AMENDMENTS. x x x x • • x x x x UTILITY: NSTAR Electric (Cambridge Electric Light) x x z z J B-0 2 6 2 9 2 0 0 PREMISE° 'Qt DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER:CONTAINED SHALL NOT BE USED FOR THE STRAUB, WESLEY STRAUB RESIDENCE Nick Ozello �:, So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A70w; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14 BUTTERNUT CIR 6.25 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES. BARNSTABLE MA 02635 ORGANIZATION, EXCEPT IN CONNECRON WITH , 24 St Martin Drive,Building 2.Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) YINGLI # YL250P-29b SHEET: REV DATE Marlborough,MA ing 2 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVHtTI R: PAID NAME 7: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE sEs000A—us—ze—u (781) 608-0593 COVER SHEET PV 1 5/7/2014 (868)-SOL-CITY(765-2489) www.sclarcity.com PITCH: 32 ARRAY PITCH:32 MP1 AZIMUTH: 186 ARRAY AZIMUTH: 186 MATERIAL: Comp Shingle STORY: 1 Story LEGEND Q (E) UTILITY METER & WARNING LABEL m� INVERTER W/ INTEGRATED DC DISCO -A - & WARNING LABELS oc IDC DISCONNECT & WARNING LABELS L_ Ji ` D \' ` Inv\' ; © AC DISCONNECT & WARNING LABELS AC Q DC JUNCTION/COMBINER BOX & LABELS_ © A DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS Digitally signed by Amir Massoumi Date: 2014.05.07 1-7-28:05 -07r00r O DEDICATED PV SYSTEM METER �H OF MA Q STANDOFF LOCATIONS f Front Of House �A� S — CONDUIT RUN ON EXTERIOR , --- CONDUIT RUN ON INTERIOR p AMIR G GATE FENCE oMASSOUMI Q HEAT PRODUCING VENTS ARE RED W CIVIL N0:5 555 L J INTERIOR EQUIPMENT IS DASHED • .o�9�Q'S �� � SITE PLAN N f Scale: 1/8" = 1' W E t 0 1' 8' 16. 5 CONFIDENTIAL- THE INFORMATION HER J B-0 2 6 2 9 2 00 PREMISE O'er DESCRIPTION: DESIGN: HERON JOB NUMBER: ���lA ■ CONTAINED SHALL NOT BE USED FOR THE STRAUB, WESLEY STRAUB RESIDENCE Nick Ozello i„�Olar�l�� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �' NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14 BUTTERNUT CIR 6.25 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: BARNSTABLE MA 02635 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St.Martin Drive,BuDding 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) YINGLI # YL250P-296 SHEET: REW. DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER' 781 608-0593 PV 2 5 7 2014 (888)-SQL-CITY(765-2489) wn.solareity.com SOLAREDGE SE60O0A-US-ZB-U \ � SITE PLAN / / S1 12'-6" 1' �tH QF M,g�9 a (E) LBW �p AMIR G SIDE VIEW OF MP1 NTS MA c . SSOVMi �. A 0 CIVIL No.S 555 MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES A�9FQ1S LANDSCAPE 64" 24" STAGGERED ems, PORTRAIT 48" 19" - t RAFTER: 2X8 @ 16"OC ROOF AZI 186 PITCH 32 STORIES: 1 ` ARRAY AZI 186 PITCH 32 C.J.: 2x6 @16"OC Comp Shingle r PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE, (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) ff(5 SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER 1 STANDOFF i Scale: 1 1/2" = 1' CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-0 2 6 2 9 2 O 0 PREMISE OWNER' DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE STRAUB' WESLEY STRAUB RESIDENCE Nick Ozello �,BBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14 BUTTERNUT CIR 6.25 KW PV Array solarCity. PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES. BARNSTABLE, MA 02635 THE SALE AND USE OF THE RESPECTIVE 25 YINGLI YL250P-29b 24 St Martln Drive,Building 2 Unit 11 ( )SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME MEET: REV: DATE: Mmlbierwo, MA 01752 PERMISSION OF SOLARCITY INC. INVERTER 781 608-0593 PV 3 5 7 2014 T: (650)ITY(765- F. (650)63B-1029 SOLAREDGE SE6000A—US—ZB—U ( STRUCTURAL VIEWS / / (eee)-soL-an(7ss-tees) .solarclty. UPLIFT CALCULATIONS i i SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. J�_O O 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER L L`.�L /„�OI���I� CONTAINED SHALL NOT BE USED FOR THE STRAUB, WESLEY STRAUB RESIDENCE - Nick Ozello BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: W•. NOR MALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14 BUTTERNUT CIR 6.25 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENrs MODULES. BARNSTABLE MA 02635 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) YINGLI # YL250P-29b g1�; REV: DAB Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T.- (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A-US-Ze-U (781) 608-0593 UPLIFT CALCULATIONS PV, 4 5/7/2014 (888)-SOL-CITY(765-2489) ■ww.solarclty.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE #SE6000A-US-ZB-U LABEL: A -(25)YINGU # YL250P-29b GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:2235933 Tie-In: Supply Side Connection Inverter; 6000W, 240V, 97.5%, w/Unifed Disco and ZB, AFCI PV Module; 250W, 226.2W PTC, H4, 40mm, YGE-Z 60, Black Frame, ZEP Enabled ELEC 1136 MR Underground Service Entrance INV 2 Voc: 37.6 Vpmax: 29.8 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 100A MAIN SERVICE PANEL E; 10OA/2P MAIN CIRCUIT BREAKER SDIarCity CUTLER-HAMMER SOLARGUARD Inverter 1 Disconnect CUTLER-HAMMER METER 4 A 1 100A/2P 6 Disconnect 5 SOLAREDGE DC+ B 35A SE6000A-US-ZB-U DC------ 1 Strings)Of 8 On MPI C rD - EGC zaov ------------ -------- - ---- I B L2 CC+ I N D6 I 3 2 %E) GND _ ____ GND _ __ GND --- ------------- - GEC T RGC10C+ OC{ 1String(s)Of17 On MP1 OG --------- ------------ -- EGC I N I (I)Conduit Kit; 3/4' EMT _J EGCfGECLi L'i z I I I I ' - GEC T-1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE I I I I I I I I I I Voc* = MAX VOC AT MIN TEMP oTT (2 Ground Rod; 5/8' x 8', Copper R (1)CUTLER-HAMMER i)DG222NRB A (1)SolarCitY#4 STRING JUNCTION BOX D� y -(2;ILSCO !IPC 4/0-/6 v Disconnect; 60A, 240Vac, Fusible, NEMA 3R AC 2x2 STRMGS, UNFUSED, GROUNDED Insulation Piercing Connector, Main 4/0-4, Tap 6-14 -0)CUTLER- AMMER DG100NB -(1)ZEP /850-1196-002 C 1)CUTLER-HAMMER DG222UR8 Ground�Neutrol Kit; 60-100A General Duty(DG) Universal Box Bracket; [PKG B] ( A -(1)CUTLER-HAMMER 8 DS16FK Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R Gass R Fuse Kit PV (5)SOLAREDGE 30D-2NA4AZS -(I)CUTLER-NAMMER�DG10ONB -(2)FERRAZ SHAWMUTT g TR35R PV BACKFEED OCP PowerBox Optimizer. 300W, H4, DC to DC, ZEP Ground eutral It; 60-100A, General Duty(DG) Fuse; 35A, 25OV, Wass RKS n� Gg (1)AWG #6, Solid Bare Copper SC SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE D SolarGuard Monitoring System -(1)Ground Rod; 5/8' x 8', Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL (1 AWG /6, THWN-2, Black 1 AWG #8, THWN-2, Black � 1 AWG f10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG #10, PV WIRE, Black V0C* =500 VDC Isc =15 ADC © (I)AWG 16, THWN-2, Red O (1)AWG #8, THWN-2, Red O IssF-(1)AWG #10, THWN-2, Red Vmp =350 VDC Imp=11.98 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=5.64 ADC (1)AWG/6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (1)AWG g10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC .. . . . (1 AWG /1,0, THWN-2,,Creen. . EGC. . . . . . . . . . . . . . . . . . . .. . . . .. . . . . . .. . . . . . . . -(1)AWG/6,.Solid Bore,Copper, GEC. . . .-(1)Conduit.Kit;.3/4'_EMT. .. .. . . . . . .. .. .. .-(1)AWC g8,.TFIWN-2,_Green . . EGC/GEC.-(1)Conduit,Kit;.3/4',EMT. . . . ,, , , ._ (1 AWG /lo, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG #10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC ®�(1)AWG J10, THWN-2, Red Vmp =350 VDC Imp=5.64 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=11.98 ADC . , . . . . (1)AWG 110, THWN72,.Creen. . . . .EGC . . . . . . . .. . . . . . . . . . . .. .. . . . . .. . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . .. . . .. . . . . .. . . . . . . . . . . . . . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: N% JB-026292 00 �,,,t, CONTAINED SHALL NOT E USED FOR THE STRAUB WESLEY STRAUB RESIDENCE Nick Ozello �:,;So�a�C�ty. BENEFIT OF ANYONE EXCEPT SOIARCITY INC., MOUNTING SYSTEM: ' ���.� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 14 BUTTERNUT CIR 6.25 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES. BARNSTABLE, MA 02635 24 St Martin Drive Bugding Z Unit 11 THE SALE AND USE OF THE RESPECTIVE (25) YINGU # YL250P-29b PAGE NAVE SHEET: REV DATE Marlborough,MA i01752 ng SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER- T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A-US-ZB-U (781) 608-0593 THREE LINE DIAGRAM PV 5 5/7/2014 (666)-SOL-CITY(765-2469) www.solarcitycom SolarCity SleekMountTM - Comp F SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed w t Installation Instructions is optimized to achieve superior strength and Zep Compatible TM modules aesthetics while minimizing roof disruption and /t O Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL I Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 t k mounting clamps,combined with the addition / O Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 to a more visually appealing system.SleekMount as"Grounding and Bonding System" ( O3 Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as i layer of shingle strengthened frames that attach directly to grounding device ® Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition ®5 Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions f �* © Secure Leveling Foot to the Comp Mount using machine Screw ®7 Place module Components ® 5/16"Machine Screw B © Leveling Foot Lag Screw Comp Mount Comp Mount Flashing _ j 0 `��,1r-I 4OMV4TjB �`„�I ��SolarCitym January 2013 LISTED sOfa�' ® January 2013 i i solar,=oo solar=oo SolarEdge Power Optimizer Module Add-On for North America p P300 / P350 / P400 SolarEdge Power Optimizer p P300 P3S0 P400 Module Add-On For North America (for 6Oce8 PV (for 72-cell PV (for 96-cell PV modules) modules)- modules) P300 / P350 / P400 °Q INPUT Rated Input DC Power•" 300 350 1 400 W ......... ........................... Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc ............................................................................. ............. ...................................... ............. �I MPPT Operating Rana ........8.:48 ...........E 8-80 Maximum Short Circuit Current(Isc) 10 .,Adc ................................................................................................................................................... . 'Hn'uunnaunn'' Maximum DC Input Current 12.5 ,Adc MaximumEfficiencY...........................................................................................99:5. ...%...... ...................................... . Weighted Efficiency 98.8 % ............................................................................................................................................................... ..... ...... .. Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc Output Volt.................................................................................................................................... . Maximum Output Voltage 60 _ Vdc rp� .OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) - _ r— Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE 'y (w+� y•� EMC FCC Part15 Class B,IEC61000-6,2,IEC61000;63. Safety......................................................................... IEC621091(class 11 safety),UL1741 _ RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc ...................................................................................... ...................................... Dimensions(W xlx H) 141x212x40:5/S.SSx8,34z159 mm/in ............................................................................ Weight including cablesl..................................................................................950/ .1.................................... ..@r/...... Input Connector MC4/Amphenol/Tyco ... .................................................................................... i Out ut Wire Type/Connector Double Insulated Amphenol Output Wire Length ...95/... I 1 2/3 9 m/ft Operating Temperature Range ..................................................................40:+85/:40_+185.......... ......... �F.... ProtectionRating........................................................................................IP65/.NEMA4................................ . y Relative HumiditY............................................................................................�.:100 ...%...... �'�wme srz ow2�a me�mdae s+mwc a�o m•zx oow.�amac airo.<e. -PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE i INVERTER 208V 480V PV power optimization at the module-level Minimum String Length(Power Optimizers) 8 0............ 18 ...................................... Maximum String Length(Power optimizers) 25 25 50 - p to more energy ............................................................................................................................................................................. Maximum Power per String 5250 6000 12750 W - Superior efficiency(99.5%) .......................................................................................................................................................................... Parallel strings of Different lengths ar Orientations Yes - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading """""..... """""""""""""""""""""""""""""""""""""""""""""""""' """"""' - Flexible system design for maximum space utilization - Fast installation with a single bolt - Next generation maintenance with module-level monitoring - Module-level voltage shutdown for installer and firefighter safety I USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL AUSTRALIA www.solaredge.us "�'�t,y=� y1'+[e'p�d8 U}*1C,•1f',L<QY'<I�AnzSu."U ti�h' dz w.�SNY4D .ru. i� uu�u1C itY •yTi+e�•]3��Y[AS)il•ll.1 CCLsss_,�e,Yf>•Nc�-^��oP+e solar Single Phase Inveders for North America solar , • ' SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE1140OA-US SE3000A-US SE38DOA-US SESOOOA-US SE6000A-US SE760OA_-US SE1000OA-US SE11400A-US SolarEdge Single Phase Inverters • OUTPUT 5200@208V 9980@208V i Nominal AC Power Output 3300 3840 5520 @240V 6000 7680 10080 @240V 11520 VA _ ........................................... ................ . ..... .................................. ............................. - F o r North America Max.AC Power Output 3650 41SO 5600 @ 208V 6000 8350 10800 @ 208V 12000 VA 6000 @240V 10950 @240V ........................................... ................ ................................................ .................................. ............................. SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ AC Output Voltage Min:Nom:Max.' 183-208-229 Vac SE760OA-US/SE10000A-US/SE1140OA-US AC Output VoltageMin:Nom:Max.' Of 211-240-264 Vac ........................................... ................ ................................................ ............................................................... AC Frequency Min..Nom:Max.' 59.3-60-60.5(with HI country setting 57-60;60.5) Hz Max Continuous Output Current 14.....' ......16 ..I...23 @ 240V I .....25.......I.... 32. ..,'I, 42 @,240V...I........48............A... . .. ........................................... ......... GFDI.................................... ............................................................1.................................................................A Utility Monitoring,Islanding " -- -rgp�werfe Protection,Country Configurable Yes Thresholds INPUT I t(201,`1 m Recommended Max.DC Power 'a w =�� (STC 4100 4800 6500 7500 9600 12400 14400 W - - .- ._ '`�,,�aF�an°�• ......).................................... ......... ................................. ................ ......... a„",w„ Transformer less,Ungrounded Yes Max.Input Voltage..................... ..........................................................500 Vdc 9 Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc ......... .. .... _ Max.Input Current 11 13 17 @ 240V 18 23.5 33 @ 224 V �_* ........................................... ...........I...............I...17.@.2V...I................ ..... ....I..30.5 @, 0V 35 Adc .. ............................. Max.Input Short Circuit Current 30 45 Adc Polarity Protection Yes ........................................... ..................................................................................................................................... Ground-Fault Isolat on Detection 600ko Sensitivity - Maximum InverterEfficiency.......... ......97.7.... .98.2 983 983 98 98 .. ._.... .,%...,. 97 5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97 5 97 5 98 @ 240V 97 5 ..... Nighttime Power Consumption <2.5 <4 W a__ f ADDITIONAL FEATURES Supported Communication Interfaces - RS485,RS232,Ethernet ZlgBee(optional) STANDARD COMPLIANCE s ---- - y Safety UL1741,UL16998(Part numbers ending In"-U"),UL1998,CSA 22.2 --' ............................... ............................................................ Grid Connection Standards _ IEEE1547 " ............... .. ................. ........................................ .............. ..................................................................... Emissions FCC part15 class 8 INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/24 6 AWG 3/4"minimum/8-3 AWG ..................... .. ................................................................... .... •• _ - —• �i f DC input conduit size/#of strings/ + - 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG range............ Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 z 7..5/ 30.5 x 12.5 x 10.5/775 z 315 x 260 In/ Switch(HxWxD 775 x 315 x 172 775 x 315 z 191 mm .... .. . . 1........................ .......... ..... ...................... . ... .. .... .......... ...................................................... ... IT.... _ Weight withWq/ Safety Switch _....____51.2/23.2....................54.7/24.7 ..........__._.....88.4/40.1 Ib/kg - ................................. . ................. ............................ ........... Cooling Natural Convection Fans(user replaceable) ........................................... . ......... ............ ................... ........... Noise <2S <50 dBA ........................................... ................................................................... ................................................................. Min.-Max.Operating Temperature 13 to+140/-25 to CAN version""-40 to+60 •F/-C The best choice for SolarEdge enabled systems Range................................... ... .........:. ( ) ................................................................................................... - Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance(part numbers ending in"-U") Protection Rating NEMA 3R •For other regional settings please contact SolarEdge support - Superior efficiency(98%) Limited to 125%for locations where the yearly average high temperature is above 770F/259C and to 135%for locations where it is below 77eF/25eC. For detailed information,refer to htto-//wwwsolaredee us/files/odfstinverter do oviciiiinn uide.odf - Small,lightweight and easy to install on provided bracket •••A higher current source may be used;the inverter will limit its input current to the values stated. ••"CAN P/Ns are eligible for the Ontario FIT and mlcmFIT(mlc oFIT en.SE11400A.Us-cm) - Built-in module-level monitoring - Internet connection through Ethernet or Wireless - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/DC Safety Switch for faster installation 57alrtscEc —�� - - -- - --- - - - - - - - - - -- - -- - -- - -- r,- RoHS USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us YGE - Z 6® YL255P-29b YL255P-29bYGE - Z 6® CELL SERIES Powered by YINGU YL255P-29b CELL SERIES YIN La oLAr1 YL245P-29b ELECTRICAL PERFORMANCE YL240P-29b U.S.Soccer Powered by Yingli Solar StandardElectrical parameters at Test Conditions(STQ_ GENERAL CHARACTERISTICS Modulo typo � ( I YL260P-296$YL255P-296 YL250P•29b YL245P-296 YL240P•29b Dimensions(L/W/H) � 64.96in(1650mm)/38.98in(990mm)/ Power output I Pm.. W 260 255 1 250 245 240 1'57m(40mm) Power output tolorancas 1AP,... % I -0/+3 Weight 43.41bs(19.7kg) • efficiency Ideal for residential Modulo eciency n. % 15.9 15.6 15.3 15.0 14.7 and commercial applications where cost savings, Voltage at P. V-1 V 30.3 30.0 29.8 29.6 29.3 Current atP. 1.ae J A es9 e.a9 8.39 8.28 8.18 PACKAGING SPECIFICATIONS installation time, and aesthetics matter most. Open<ircultvoltage V- : V 37.7 37.7 37.6 37.5 37.5 Number of modules per pallet } 26 Short-circuit current 1.. A 9.09 �i 9.01 8.92 8.83 8.75 Number of pallets per 40'container l 28 .� STC:I000w/m2 irradiance,250C cell temperawm,AM 1.59 spectrum according to EN 60904-3 Packaging box dimensions ' • • Average rated,,efficiency reduction of 3.3%at 200W/m2 according to EN 60904-1 gin9 6732in 071Dnm)/45.67i.0160mm)/ (L/W/H) ; 46.38m It 178m) Lower balance-of-system costs with Zep Electrical parameters at Nominal Operating Cell Temperature(N• Box weight l 120216s(545kg) Compatible'"frame. Power output P... w 189.7 1 186.0 1 182.4 178.7 175.1 F• Reduce on-roof labor costs by more than =" Voltage at P. V.,a V 27.6 27.4 27.2 27.0 26.8 Units:inch(mm) 25%- \ Current at P... I.,a A 6.87 6.79 6.71 6.62fi7 4 38.98 990 Open-circuit voltage V: V 34.8 34.8 34.7 34.6 .6 36.85 936 1.57(40) Leverage the built-in grounding system- \ she ec;r<°cae.rant 1 A 7.35 zze 721 7.14 $ if it's mounted,it's grounded. NOCTopen-cinvltmodule operation temperature at800W/m2im,diance,20°C ambient temperature,lm/swindspeed - Decrease your parts count-eliminate screws, m THERMAL CHARACTERISTICS rails,mounting clips,and grounding hardware. Nominal operating coll temperature NOR+ Y 46+/-2 Temperature coefficient of P.., Y I%/•C -0.42 • • O O Temperature coefficient of V. 0-19fJ°C -0.32 Minimize roof penetrations while maintaining Temperature coefficient of 1.. °. %Ic 0.05 Grounding hJ(6.5.8) b-o0.236(6) tl the system's structural integrity. QGpMPgTj Temperature coefficient ofV.00 �e.•.�'%/'ci -0.42 11,Invest in an attractive solar array that includes a black frame,low mounting profile,and OPERATING CONDITIONS aesthetic array skirt. �FA Max.s Ito 100ovoc Mounting ho COMPP��O ystem voltage 4-0256x0.3Increase energy output with flexible module Max.series fuse rating1sAlayouts(portrait or landscape). Limiting,e -current I 15A Drainage ho8-0.12x0.31 Trust in the reliability and theft-resistance of Operating temperature range .40 to 185•F(-40 to 85•C) the Zep Compatible"system. Max.static load z40023 3.940 00) Max.hailstone impact(diameter/velocity) 25mm/ 3n1/s AC SOLUTION OPTION i Leading limited power warranty'ensures // 047(1 ) �\ I 91.2%of rated power for 10 years,and 80.7% / The YGE-Z Series is now available as of rated power for 25years. CONSTRUCTION MATERIALS / \ i--- -- ---- -------I Front cover(material/thickness) low-iron tempered glass/3.2mm I r 11 Nn�pa!sl an Enphase Energized'"AC Solution. I i PJSECTIONC-C This solution delivers optimum Cell(quantity/material/dimensions/ 60/multicrystalline silicon10-year limited product warranty. number of busbars) 156mm x 156mm/2 or 3performance and integrated intelligence. ;The Enphase M215-Z Zep Compatible f- _ .. . - _ _-_ __ _._ Encapsulant(materiaq ethylene vinyl acetate(EVA) 1.38(35)Microinverter is designed to connect 'In compliance with our warranty terms and conditions. Frame(material/color/edge sealing) anodized aluminum alloy/black/silicone or tape directly into the Z Series module groove,eliminating 000 Junction box(ngross protection rating) aIP65 l _ _ Warning:Read the Installation and User Manual in its entirety the need for tools or fasteners-all with one easy step. { Cable(length/cross-sectional area) 1200mm/4mm2 before handling,installing,and operating Yingli modules. • • �„�"^^^•""^�""w • Connector(type/ingress protection rating) Amphenol H4/aIP67 I Our Partners UL 1703 and ULC 1703,CEC,FSEC,ISO 9001:2008,ISO _ 14001:2004,BS OHSAS 18001:2007,SA8000 Intelligent real-time monitoring at the system r- - ' -- - _ and module level with ( if you buy from Yingli Americas,Yingli Americas The specifications in this datasheet are not guaranteed and are subject to change without prior notice. (I( US �, ac as the importer and complies Mth all This datasheet complies with EN 50380:2003 requirements. Enlighten. ( C I atsppliwblo tariffs.COstomem can buy from Yingli LISTED _ ' Americas with no worry that they will be liable for tn+o2ov0uac 44DD eo0un any import tariffs. - o� Yingli Green Energy Americas,Inc. info®yingliamericas.com Tel:+1 (888)686-8820 YIN�U,^�OLAIR YINGLISOLAR.COM/US NYSENGE Y I N G L I S O L A R.C O M/U S Yingli Solar 0 Yingli Green Energy Holding Co.Ltd. I YGEZ60CellSeries_US_201403 V01 U.S.Soccer Powered by Yingli Solar