HomeMy WebLinkAbout0226 HARBOR HILLS ROAD - Health 226 Harbor Hills Road, Centerville
r'
llll
UPC 12534
No.21_ 531,,OR �
HASTINGS#MN
COMMONWEALTH OF MASSACHUSETTS
EXECUTIVE OFFICE OF,ENVIRONMENTAL AFFAIRS
x DEPARTMENT OF ENVIRONMENTAL PROTE
ONE WINTER STREET, BOSTON, MA 02108 617-292-5500
WILLIAM F.WELD T 2 4 19e' TRUDY-COXE
Governor r0, y & retary
�'NOf
ARGEO PAUL CELLUCCI HEA(Hp ArABCEDAVID�SS RUHS
Lt.Governor SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FOR ym issioner
PART A 8
CERTIFICATION 4
226 Harbor Hills Rd
Property Address: Centerville Address of Owner: Leonard Glynn
Date of Inspection: (If different) 1 Emerson Place
Name of Inspector: Wm E Robinson Sr Apptt� 1 6D
I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 (310 CMR TS.b00)
Company Name: Wm E Robinson Septic Service Boston, MA 02114
Mailing Address: PO Box 1 089 , Cent ervi 1 1 e, MA 02632
Telephone Numbers 5 0 8 7 7 5—R 7 7 h
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate
and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and
maintenance of on-site sewage disposal systems. The system:
_Passes
_ Conditionally Passes
Needs Furthe"r Evaluation By the Local Approving Authority
_ Fails q
11
Inspector's Signature: lu r Date: `v��~
The System Inspector shall submit a copy of this inspection report to the Approving Authority within thirty (30) days of completing this
inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit
the report to the appropriate regional office of the Department of Environmental Protection. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
INSPECTION SUMMARY: Check A, B, C, or D:
A) SYSTEM PASSES:
1 have not found any information which indicates that the system violates any of the failure criteria as defined in 31d CMR 15.303.
Any failure criteria not evaluated are indicated below.
COMMENTS:
B YSTEM CONDITIONALLY PASSES:
One or more system components as described in the "Conditional Pass" section need to be replaced or repaired. The system, upon
completion of the replacement or repair, as approved by the Board of Health, will pass.
Indic a yes, no, or not determined (Y, N, or ND). Describe basis of determination in all instances. If"not determined", explain why not.
The septic tank is metal, unless the owner or operator has provided the system inspector with a copy of a Certificate of
Compliance (attached) indicating that the tank was installed within twenty (20) years prior to the date of the inspection; or
the septic tank, whether or not metal, is cracked, structurally unsound, shows substantial infiltration or exfiltration, or tank
failure is imminent. The system will pass inspection if the existing septic tank is replaced with a conforming septic tank
as approved by the Board of Health.
( "wised 04/25/97) Page 1 of 10
DEP on the World Wide Web: http:11www.magnet.state.ma.us/dep
e'j Printed on Recycled Paper
c
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: �' 7
B) SYSTEM CONDITIONALLY PASSES (continued)
Sewage backup or breakout or high static water level observed in the distribution box is due to broken or obstructed
pipe(s) or due to a broken, settled or uneven distribution box. The system will pass inspection if(with approval of the
Board of Health). Describe observations:
broken pipe(s) are replaced
obstruction is removed
distribution box is levelled or replaced
The system required pumping more than four times a year due to broken or obstructed pipe(s). The system will pass
inspection if(with approval of the Board of Health):
broken pipe(s) are replaced
obstruction is removed
Cj FURTH R EVALUATION IS REQUIRED BY THE BOARD OF HEALTH:
onditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect the
ublic health, safety and the environment.
1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES THAT THE SYSTEM IS NOT FUNCTIONING IN A MANNER
WHICH WILL PROTECT THE PUBLIC HEALTH AND SAFETY AND THE ENVIRONMENT:
_ Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
2) YSTEM WILL FAIL UNLESS THE BOARD OF HEALTH (AND PUBLIC WATER SUPPLIER, IF APPROPRIATE) DETERMINES THAT
HE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECTS THE PUBLIC HEALTH AND SAFETY AND THE
NVIRONMENT:
The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet to a surface water supply or
tributary to a surface water supply.
_ The system has a septic tank and soil absorption system and the SAS is within a Zone I of a public water supply well.
The system has a septic tank and soil absorption system and the SAS is within 50 feet of a private water supply well.
The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a
private water supply well, unless a well water analysis for coliform bacteria and volatile organic compounds indicates that
the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or
less than 5 ppm. Method used to determine distance (approximation not valid).
3) O HER
(revised 04/25/97) Page 2 of 10
i
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: 9—� - 7
D) S TEM FAILS:
You m t indicate ei;,,er "Yes" or "No" as to each of the following:
have determined that the system violates one or more of the following failure criteria as defined in 310 CMR 15.303. The basis
f r this determination is identified below. The Board of Health should be contacted to determine what will be necessary to correct
th failure.
Yes No
Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool.
Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or
cesspool.
Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
Liquid depth in cesspool is less than 6" below invert or available volume is less than 1/2 day flow. .
Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).
Number of times pumped _.
Any portion of the Soil Absorption System, cesspool or privy is below the high groundwater,elevation.
Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply.
Any portion of a cesspool or privy is within a Zone I of a public well.
Any portion of a cesspool or privy is within 50 feet of a private water supply well.
Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no
acceptable water quality analysis. If the well has been analyzed to be acceptable, attach copy of well water analysis for
coliform bacteria, volatile organic compounds, ammonia nitrogen and nitrate nitrogen.
EJ LA GE SYSTEM FAILS:
You m st indicate either "Yes" or "No" as to each of the following:
The'following criteria apply to large systems in addition to the criteria above:
The system serves a facility with a design flow of 10,000 gpd or greater (Large System) and the system is a significant threat to
public health and safety and the environment because one or more of the following conditions exist:
Yes No
_ the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area- IWPA) or a mapped Zone II of a
public water supply well)
The o er or operator of any such system shall bring the system and facility into full compliance with the groundwater treatment program
requirgmenfs of 314 CMR 5.00 and 6.00. Please consult the local regional office of the Department for further information.
r�
(revised 04/25/97) Page 3 of 10
1
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: T-.x 4 -g 7
Check if the following have been done: You must indicate either "Yes" or "No" as to each of the following:
Yes No
Pumping information was provided by the owner, occupant, or Board of Health.
None of the system components have been pumped for at least two weeks and the system has been receiving normal
flow rates during that period. Large volumes of water have not been introduced into the system recently or
/ as part of this inspection.
As built plans have been obtained and examined. Note if they are not available with N/A.
_ The facility or dwelling was inspected for signs of sewage back-up.
IJ/ _ The system does not receive non-sanitary or industrial waste flow.
V _ The site was inspected for signs of breakout.
All system components, excluding the Soil Absorption System, have been located on the site.
The septic tank manholes were uncovered; opened, and the interior of the septic tank was inspected for condition of
baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge, depth of scum.
s / The size and location of the Soil Absorption System on the site has been determined based on:
The facility owner (and occupants, if different from owner) were provided with information on the proper maintenance of
Sub-Surface Disposal System.
_ Existing information. Ex. Plan at B.O.H.
_ Determined in the field (if any of the failure criteria related to Part C is at issue, approximation of distance is
unacceptable) [15.302(3)(b)]
J)
Y:
(roviaad 04/45/97) -Page 4 of 10
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: �� �.. /7
FLOW CONDITIONS
RESIDENTIAL:
Design flow: 33 '0 e.p.d./bedroom for S.A.S.
Number of bedrooms: 3
Number of current residents: 0
Garbage grinder (yes or no):..1d--PJ
Laundry connected to system (yes or no):4L,?.S
Seasonal use (yes or no):-)�LL-'s
Water meter readings, if available (last two (2) year usage (gpd): 1995 — 29 , 000 gals_
Sump Pump (yes or no): h-o 1996 - 6,000 gals
Last date of occupancy:
COMbtERCIAUI NDUSTRIAL:
Type o establishment:
Design ow: gallons/day
Grease t ap present: (yes or no)_
Industria Waste Holding Tank present: (yes or no)_
Non-san tary waste discharged to the Title 5 system: (yes or no)_
Water eter readings, if available:
Last to of occupancy:
OTHE : (Describe)
Last d e of occupancy:
GENERAL INFORMATION
PUMPING RECORDS and source of information:
x,'44
System pux1ped as part of inspection: (yes or no)_
If yes, volume pumped: gallons
Reason for pumping:
TYPE OF SYSTEM
L,/Septic tank/distribution box/soil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system (yes or no) (if yes, attach previous inspection records, if any)
I/A Technology etc. Copy of up to date contract?
Other
APPROXIMATE AGE of all components, date installed (if known) and source of information: .5
Sewage odors detected when arriving at the site: (yes or no)LO
(revised 04/25/97) Page 5 of 10
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: ?_;z- --g-
BUIL NG SEWER:
(Locate n site plan)
Depth low grade:
Material f construction: _cast iron _40 PVC _other (explain)
Distanc from private water supply well or suction line
Diamet
Comme ts: (condition of joints, venting, evidence of leakage, etc.)
SEPTIC TANK:_
(locate on site plan)
Depth below grade:
Material of construction: _concrete _metal _Fiberglass _Polyethylene _other(explain)
If tank is metal, list age _ Is age confirmed by Certificate of Compliance _(Yes/No)
Dimensions:�S` s v '7
Sludge depth:
Distance from top of sludge to bottom of outlet tee or baffle:1
Scum thickness: /--G
Distance from top of scum to top of outlet tee or baffle: S
Distance from bottom of scum to bottom of outlet tee or baffle:
How dimensions were determined:
Comments:
(recommendation for pumping, condition of inlet and outlet tees or baffles, depth of liquid level in relation to outletAvert, structural
integrity, evidence of leakage, etc.) ��- �' ate- ap I< Ae�-5 .®/'F .s IL ,oG
GREAS TRAP:
(locate n site plan)
Depth low grade:
Materi of construction: _concrete _metal _Fiberglass _Polyethylene —other(explain)
Dime ions:
Scum t 'ckness:
Distance from top of scum to top of outlet tee or baffle:
Distance rom bottom of scum to bottom of outlet tee or baffle:
Date of I st pumping:
Comm nts
(rec mendation for pumping, condition of inlet and outlet tees or baffles, depth of liquid level in relation to outlet invert, structural
integri , evidence of leakage, etc.)
(revised 04/25/97) Page 6 of 10
.SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: q 4 _ of rf
TIG OR HOLDING TANK: (Tank must be pumped prior to, or at time, of inspection)
(locate on site plan)
Depth low grade:
Material f construction: _concrete _metal _Fiberglass _Polyethylene _other(explain)
Dimens ns:
Capaci : gallons
Design ow: gallons/day
Alarm le el: Alarm in working order_Yes; _ No
Date of p evious pumping:
Comment
(conditio of inlet tee, condition of alarm and float switches, etc.)
DISTRIBUTION BOX:
(locate on site plan)
Depth of liquid level above outlet invert:
Comments:
(note if level and distribution is equal, evidence of solids carryover, evidence of leakage into or out of box, etc.)
PUMP C AMBER:_
(locate on site plan)
Pumps i working order: (Yes or No)
Alarms n working order (Yes or No)
Corn ts:
(note co ition of pump chamber, condition of pumps and appurtenances, etc.)
(revised 04/25/97) Page 7 of 10
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: g (e—Q-1
SOIL ABSORPTION SYSTEM (SAS):_,,
(locate on site plan, if possible; excavation not required, but may be approximated by non-intrusive methods)
If not determined to be present, explain:
Type:
leaching pits, number:_
leaching chambers, number:_
leaching galleries, number:
leaching trenches, number,length:
leaching fields, number, dimensions:
overflow cesspool, number:_
Alternative system:
Name of Technology:
Comments:
(note condition of�soi�signs of hydraulic faiC.lure, level of ponding, condition of vegetation, etc.) _
.. 117
- - /a
G d ..
-r.� ,o ,
CE)en
S: _
(losite plan)
Nund configuration:
Deof liquid to inlet invert:Deolids layer:
Decum layer:
Dis of cesspool:
Mf construction:
Inof groundwater:
nflow (cesspool must be pumped as part of inspection)
Comment
(note con ition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.)
PRIVY:
(locate site plan)
Materials f construction: Dimensions:
Depth of s I ids:
Comments
(note cond tion of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.)
(revised 04/25/97) Page 6 of 10
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: `j—�4 _c
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent references landmarks or benchmarks
locate all wT'Uj
I within 100' (Locate where public water supply comes into house)
b
(revised 04/25/97) Page 9 of 10
I
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 226 Harbor Hills Rd, Centerville
Owner: Glynn
Date of Inspection: ��!, — °1 7
Depth to Groundwater 16 Feet
Please indicate all the methods used to determine High Groundwater Elevation:
��Obtained from Design Plans on record
Y Observation of Site (Abutting property, observation hole, basement sump etc.)
Determine it from local conditions
Check with local Board of health
Check FEMA Maps
Check pumping records
Check local excavators, installers
Use USGS Data
Describe in your own words how you established the High Groundwater Elevation. (Must be completed)
jx l/c iG S S 3 i-lo s 4 s a n
(revised 04/25/97) Page 10 of 10