Loading...
HomeMy WebLinkAbout0044 HI-ONA HILL ROAD - Health (2) _ 44 Hi-Ona-Hill Rd. , Centerville A= 207-089 r� I No. 42101/3 URA EssELTE 10%(a o a e o ` Commonwealth of Massachusetts0?0 Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments Y ry is 44 Hi Ona Hill Road Property Address Brian&Sharon Walsh Owner Owner's Name " -"- information is Centerville ✓ Ma 02632 7I7/2020 required for every page. Cityfrown State Zip Code Date of Inspection z Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When filling out forms A. Inspector Information on the computer, use only the tab Sean M. Jones key to move your Name of Inspector ...... — cursor-do not S.M.Jones Title V Septic Inspection use the return Company Name — ---"- key. 74 Beldan Lane Company Address Centerville Ma 02632 Mf City(rown State Zip Code r 774-248-4850 smjonestitle5@gmail.com, SI4522 Sean@smjonestitle5.com _ License Number B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 16.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined that the system: 1. ® Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails - ..-" _ 7t7/2020 Ins�W&or's Signat...u---..--._.re _ Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform In the future under the same or different conditions of use. tsinsp.doc-rev.7i2812018 rules Official ins pection edion Forth.Subsurface Sew age Disposal SYstern page t of 18 Commonwealth of Massachusetts ` -- _0 Title 5 Official Inspection Form = _ - tea Subsurface Sewage Disposal System Form -Not for Voluntary Assessments ' y r 44 Hi Ona Hill Road Property Address __..._............_....___ Brian & Sharon Walsh Owner Owner's Name -- Information is required Centerville Ma 02632 7/7/2020 page.rd for every Citylfown � -- State tip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: The property located at 44 Hi Ona Hill Rd Centerville is served by a Title V septic system consisting of a 1500 gallon septic tank, distribution box and 3 Infiltrators. Although the system was found to be in proper working condition at the time of inspection this report does not guarantee future performance under similar or increased usage. 2) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no"or"not determined" (Y. N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old" or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. "A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND(Explain below): t5insp.doc•rev.712612016 Title 5 Official Inspection Form Subsurface Sewage Disposal System•Page 2 of f8 Commonwealth of Massachusetts Title 5 official Inspection Form a Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address Brian &Sharon Walsh Owner Owner's Name information i e Centerville Ma 02632 7/7/2020 required for every �._ page. Cityfrown State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes(coot.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): I El The system__-----._........- yste required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced (=1 Y ❑ N ❑ ND(E)fplain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): 3) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 16.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: 15insp.doe•rev 7/WW8 Title 5 official Inspection Form:Subsurface Sewage Disposal system-Page 3 of 18 I Commonwealth of Massachusetts -- Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments' 44 Hi Ona Hill Road Property Address '-- Brian&Sharon Walsh Owner Owner's Name - __...................__ _. information is Centerville Ma 02632 7/7/2020 required for every , page. Cityrrown State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health and Public Water Supplier, if an Y � PP YI determines that the system Is fu nctioning unctloning in a manner that protects the public health safety and environment: ❑ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well•" Method used to determine distance: This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must Indicate"Yes" or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool 15insp.Eac•rev 7128/2018 Tills 5 Otfi"l Inspection Form Subsurface Sewage Disposal SYatem•Page 4 0118 f Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary 9 P Y ry Assessments 44 Hi Ona Hill Road Property Address Brian &Sharon Walsh Owner Owners Name information required for every Centerville Ma 02632 7/7/2020 page, CityfTown state Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than %day-flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ® ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. i ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system falls. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system.the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the questions in Section CA. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well f5inap.cloc-rev 712812nt9 Title 5 Official Inspection Form Subsurface Sewage Disposal System•Page 5 of 19 r _ Commonwealth of Massachusetts -_ co Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address -- - Brian &Sharon Walsh Owner Owners Name - - w,._._.._..............._._....._._ information Is Centerville Ma 02632 7J7/2020 required for every —.-_- _.. ___...._.............._._...._.....�_ page. City/Town State Zip Code Date of Inspection C. Inspection Summary (coot.) If you have answered"yes"to any question in Section C.5 the system is considered a significant threat, or answered "yes" to any question in Section CA above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate"yes"or"no"for each of the following for aff inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ © Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined?(If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS)on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[310 CMR 15.302(5)] 15insp.doc•rev.7/262018 Title 5 Ofrtciai Inspection form.Subsurface Sewage Disposal System•Pege 6 or 18 I t Commonwealth of Massachusetts I w Title 5 official Inspection Form -- . ` Subsurface Sewage Disposal System Form-Not for Voluntary Assessments �Y4' 44 Hi Ona Hill Road Property Address Brian & Sharon Walsh Owner Owner's Name --.-----._ information is Centerville Ma 02632 7M2020 required for every �._ page. Cityrrown State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms(design): 3 Number of bedrooms(actual): 3 -..__. DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330pd.---- Description: Number of current residents: 2 Does residence have a garbage grinder? ❑ Yes ® No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: Is laundry on a separate sewage system?(Include laundry system inspection Yes ® No information in this report.) Laundry system inspected? ❑ Yes ® No Seasonaluse? ® Yes ❑ No Water meter readings, if available last 2 ears usage 9 ( y 9 (gpd))� Detail: Sump pump? ❑ Yes ® No Last date of occupancy: current Date t5insp.doc•rev.7/2612018 Title 5 Official Inspecnon Form Subsudece Sewage Disposal System-Page 7 of IS Commonwealth of Massachusetts y ^ Title 5 official Inspection Form _._ l Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 9 P Y rY . '� 44 Hi Ona Hill Road Property Address Brian & Sharon Walsh Owner Owner's Nameinformations i Centerville Ma 02632 7/7/2020 required for every ---_........_._..___. T _ page. Cltyfrown State Zip Code Date of Inspection D. System Information (cont.) 2. Commerciallindustrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): __.�._.�....-__..............._ __..._.___.. Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): -- Grease trap present? ❑ Yes ❑ No Water treatment unit present? ❑ Yes 0 No If yes, discharges to: -------- --- Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: ---- ------ Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons -- How was quantity pumped determined? --- -- Reason for pumping: 151nsp eoc-rev,7126=18 Ttile 5 official Inspection Form:Subsurface Sewage Disposal System-page 8 of 18 Commonwealth of Massachusetts Title 5 official Inspection Form "?' Subsurface Sewage Disposal System Form-Not for Voluntary Assessments $`r 44 Hi Ona Hill Road Property Address Brian&Sharon Walsh Owner Owner's Name information is Centerville Ma 02_632 7/7/2020 required for every _ page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system(yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner)and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed (if known)and source of information: system installed 5/5/1997 per town records Were sewage odors detected when arriving at the site?" ❑ Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: 1.5 Meet Material of construction: ❑cast iron ®40 PVC ❑ other(explain): --- Distance from private water supply well or suction line: feet- — Comments (on condition of joints, venting, evidence of leakage, etc.): Joints in good condition, no leakage, vented through roof. t5insp.d=-rev.RM2018 Title 5 Offivat inspection Fom1:Subsurface Sewage Disposal System-Page 9 of to j Commonwealth of Massachusetts Title 5 official Inspection Form �! Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road _ Property Address Brian & Sharon Walsh Owner Owner's Name --- - Information Is Centerville _Ma 02632 7/7/2020 required for every __. page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 6. Septic Tank(locate on site plan): Depth below grade: feet Material of construction: ®concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: -- years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No 1500 gallons Dimensions: -- ---- ----- --- Sludge depth: 5 3' Distance from top of sludge to bottom of outlet tee or baffle — - ---------- 2" Scum thickness - ------ Distance from top of scum to top of outlet tee or baffle 7. - Distance from bottom of scum to bottom of outlet tee or baffle 101, How were dimensions determined? Opened covers and took measurements Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tank does not need to be cleaned now but should be done soon and again every 2 years for proper maintenance. water level was even with outlet, tank was not leaking and was structurally sound. Mns .doc•rev.7f26=1 B P Title S Official Inspection Form Subsurface Sewage Disposal System•Page 10 0118 Commonwealth of Massachusetts - Title 5 Official inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road _ Property Address Brian& Sharon Walsh _ Owner Owner's Name information is Centerville Ma 02632 7/7/2020 required for every page. - City/Town State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet Material of construction: ❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle -- Date of last pumping: Hate __________ Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t6irwo,doc•rev.MV207® Title 5 official Inspection Form,Subsurface Sewage Ursposal system-Page 49 of 1a Commonwealth of Massachusetts -� Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address Brian &Sharon Walsh Owner Owner's Name — _................_.................__.... . ..� ,. . information is Centerville Ma 02632 7/7/2020 required for every _- page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 8. Tight or Holding Tank (cont.) Alarm present: ❑ Yes ❑ No Alarm level: -- -- Alarm in working order: ❑ Yes' ❑ No Date of last pumping: Date Comments(condition of alarm and float switches, etc.): Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box (if present must be opened) (locate on site plan): Depth of liquid level above outlet invert oil— --------- --- — ---- --- -- ----- Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Distribution box was level and in good condition with no rot. Water level was even with outlet invert with no signs of past backup. tSlnsp.doc rev.712 612 01 8 Title 5 Official trtsoection forth Subsurface Sewage nispnsal System-Page 12 oP 18 Commonwealth of Massachusetts Title 5 official Inspection Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address - Brian&Sharon Walsh Owner Owner's Name information is Centerville Ma 02632_ 7/7/2020 required for every _ __. page. City/Town _ State Zip Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No` Alarms in working order: ❑ Yes ❑ No' Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.): *If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: ❑ leaching pits number: 3 Infiltrators® leaching chambers number: --- --- ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Typeiname of technology: --- — lsinsp•doc•rev,712&M18 Title 5 Official Inspection Form.Sutmurface Sewage Disposal System•Page 13 of 18 � •, Commonwealth of Massachusetts s Title 5 official Inspection Form } Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address Brian & Sharon Walsh OwnerOwner's Name -----..._..._...._.......___.....�_ ..�_.___.__ ___.._.._-m.._......_._...-�_�___ information is required for®very Centerville _ Ma 02632_ 7/7/2020 page. CityJTown — State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): s.a.s. consists of 3 Infiltrators in a 25'x11'x2'trench. Leaching facility was video inspected from d-box and was found with 3"standing water and no signs of past hydraulic overloading. 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration - Depth-top of liquid to inlet invert - Depth of solids layer ------ Depth of scum layer _ _ ----------------.__..__. Dimensions of cesspool - Materials of construction __ _._-.................. _.---_..._...._.........._.._—.....__.__._... Indication of groundwater inflow ❑ Yes ❑ No Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Mrisp.00e•rov.712612018 Tale 5 official Inspection Fort.Subsufloce Sewage Disposal System-Page 14 of 18 Commonwealth of Massachusetts Title 5 official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments .. . ... �- 44 Hi_Ona Hill Road Property Address Brian&Sharon Walsh _ Owner Owners Name Informatrequired is Centerville Ma 02632 7/7/2020 required for every page. Cityfrown State Zip Code Date of Inspection D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: ------- - -- - -- Dimensions Depth of solids Comments(note condition of soil,-signs of hydraulic failure, level of ponding, condition of vegetation, etc.): €Slnsp.doa•rev.7lA 018 Title 5 Official Inspection Farm:Subsurface Sewage Disposal System•Page 15 or 10 Commonwealth of Massachusetts - = Title 5 Official Inspection Form t1 Subsurface Sewage Disposal System Form-Not for Voluntary Assessments .�- E € ' 44 Hi Ona Hill Road Property Address Brian & Sharon Walsh Owner ,...-.._ Owner's Name information is required for every Centerville Ma 02632 7/7/2020 page. Cityfrown State Zip Code Date of Inspection D. System Information (coat.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately c> C) Al IVO l A Z. 4 6 gZ 1b A3 `4 7 3 3d 6 Aj TY S�6 t5msp.doc-rev.7r M018 Title 5 Official Inspectiun Form Subsurface Sewage Disposal System•Page 16 of 18 I Commonwealth of Massachusetts tY'DD) Title 5 official Inspection Form �= Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address Brian &Sharon Walsh Owner Owner's Name information is required for every Centerville Ma 02632 7/7/2020__.__......_._..__................................_...._...____.�. ..�.. page. CitylTown State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ❑ Check Slope ❑ Surface water ❑ Check cellar ❑ Shallow wells Estimated depth to high ground water: 12'+ feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ❑ Observed site(abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health -explain: ❑ Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: Groundwater was established by accessing town of Barnstable groundwater contour maps. Before filing this Inspection Report, please see Report Completeness Checklist on next page. f5urspAx.•rev.706/2018 Title 5 Official inspection Form.Subsurface Sewage Disposal System•Page 17 of 18 Commonwealth of Massachusetts ry -- Title 5 Official Inspection Form ' : ! Subsurface Sewage Disposal System Form Not for Voluntary Assessments 44 Hi Ona Hill Road Property Address Brian &Sharon Walsh Owner Owner's Name Information IsCenterville Ma 02632 7/7/2020 required for every _ _ _ ___ page. CitylTown State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked ® C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4 (Failure Criteria)and 6(Checklist)completed ® D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included 15insp.doc•rev.7/26/2l)t6 Title$Official Inspection Form:Subsurface Sewage Disposal System•Pap to of is TOWN OF BARNSTABLE ' LOCATION On. � t, SEWAGE # VILLAGE r--- -- ASSESSOR'S MAP & LOT 20= <.Q INSTALLER'S NAME & PHONE NO. 20 b I ►—S a 7 '2 SEPTIC TANK CAPACITY 0 LEACHING FACILITY:(type) /r—02. .—tY (sue) i NO. OF BEDROOMS PRIVATE WELL OR PUBLIC WATER .* BUILDER OR OWNER DATE PERMIT ISSUED: l� i i DATE COMPLIANCE ISSUED-..l---3F--9 I VARIANCE GRANTED: Yes i I i v r . c No. 7.- L Fee $50. 00 / / THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: / PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE., MASSACHUSETTS 1TGJ Zipprication for Migaal 6p5tem Construction Permit Application for a Permit to Construct( )Repair(X)Upgrade( )Abandon( ) ❑Complete System ❑Individual Components Location Address or Lot No. 44 H i-Ona-Hill Rd Owner's Name,Address and Tel.No. 7 7 5—2 3 3 3 Centerville, MA Frank Walsh Assessor's Map/Parcel 44 HI-Ona-Hill Rd, Centerville Installer's Name,Address,and Tel.No. 7 7 5—8 7 7 6 Designer's Name,Address and Tel.No. Wm E Robinson Sr Septic Service PO Box 1089 , Centerville, MA Type of Building: Dwelling No.of Bedrooms 3 Lot Size sq. ft. Garbage Grinder( n9 Other Type of Building No. of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow gallons per day. Calculated daily flow gallons. Plan Date Number of sheets Revision Date Title Size of Septic Tank Type of S.A.S. Description of Soil -,a n d Nature of Repairs or Alterations(Answer when applicable) Title 5 Septic repair consisting of a 1500 gallon tank, D-box, and 3 stonepacked high capacity infiltrators . Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued by thi§Bqg Wo ealth. Signed s Date G���""g Application Approved r '�< Date Application Disapproved for the following reasons Permit No. �'�--— — Date.Issued d�Z - — - No. / /�j... Fee f THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: F_ - TOWN'OF BARNSTABLES MASSACHUSETTS PUBLIC HEALTH DIVISION ZIppYication for �Digaaf *pztem Con.5truction Vermit Application fora Permit to Construct( )Repair(x)Upgrade( )Abandon( ) ❑Complete System ❑Individual Components i Location Address or Lot No. 44 H i—Ona—Hill Rd Owner's Name,Address and Tel.No. 7 7 5—2 3 3 3 Centerville, MA Frank Walsh Assessor'sMap/Parcel 44 HI-Ona-Hill Rd, Centerville. Installer's Name,Address,and Tel.No. 7 7 5-8 7 7 6 Designer's Name,Address and Tel.No. Wm E Robinson Sr Septic Service PO Box 1089, Centerville, MA Type of Building: Dwelling No.of Bedrooms 3 Lot Size sq.ft. Garbage Grinder(n j Other Type of Building No Showers( ) Cafeteria( ) Other Fixtures Design Flow gallons per day. Calculated daily flow gallons. Plan Date Number of sheets Revision Date i Title Size of Septic Tank Type of S.A.S. '�'1 `•Description of Soil sand Nature of Re airs or Alterations(Answer when applicable Title 5 Septic repair consisting, of a 1900 gallon tank, D-box, stormpacked high capacity Infiltrators. �� o Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system [' in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued by thi Bo o ealth. Signed Date Application Approved Date 4/1IF „� 7 Application Disapproved for the following reasons Permit No. /� �'` Ida Is ued«.. C) --- ----- -- ---------------- y- THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE, MASSACHUSETTS Walsh Certificate of Compliance THIS IS TO CERTIFY, that the On-site Sewage Disposal System Constructed( )Repaired (x )Upgraded( ) Abandoned( )by at 44 Hi-Ona-Hill Rd Centerville MA has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. l dated Installer Wm E Robinson Sr Septic Servilo(signer The issuance of this permit shall not be construed as a guarantee that the system will function as designed. Date ,) Inspector " No. % ��' � / ! --------------------------Fee $50.00 THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION - BARNSTABL'E., MASSACHUSETTS Walsh 1=igpOga1 *p!5tem COngtruction Vermit Permission is hereby granted to Construct( )Repair( x)Upgrade( )Abandon( ) System located at 44 Hi-Ona-Hill Rd, Centerville, MA Installer: §m E Robinson Sr Septic Service and as described in the above Application for Disposal System Construction Permit. The applicant recognizes his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided: Construction must be completed within three years of the date of th' rmit Date: Approved , �i �� �,✓ Gl/fi9y„ r t NOTICE: This form is to be used for the repair of failed septic systems only CERTIFICATION OF SKETCH AND APPLICATION FOR A DISPOSAL WORKS CONSTRUCTION PERMIT(WITHOUT DESIGNED PLANS) ) I,William E. Robinson, Sir hereby certify that the application for disposal works construction permit signed by me dated0���®'�i , concerning the property located at 44 Hi-Ona-Hill Rd, Centerville, MA meets all of the following criteria: * There are no wetlands within 300 feet of the proposed septic system. * There are no private wells within 150 feet of the proposed septic system. * The obseved groundwater table is 14 feet or greater below the bottom of the leaching facility. * There is no increase in flow and/or change in use proposed. * There are no variances requested or needed. SIGNED: ` DATE LICENSED SEPTIC SYSTEM INSTALLER IN THE TOWN OF BARNSTABLE NUMBER 60 (Attach a sketch plan of the proposed system. Also if the licensed installer proposes a certification plot plan,this plan should be submitted). ll� OJ Q r ✓ ✓`. .�vim"- t1 j 1 J Illy/) "o TOWN OF BARNSTABLE d: LOCATION <� ®�"� �`'L. i SEWAGE # VILLAGE C. ASSESSOR'S MAP & LOT'ap7t 08 7 . INSTALLER'S NAME PHONE NO. /l �j /�- $ ?✓ t�"" ' SEPTIC TANK CAPACITY LEACHING FACILITY:(type) /��- „ �- (size) NO. OF BEDROOMS PRIVATE WELL OR PUBLIC WATER , BUILDER OR OWNER ZAJAlc DATE PERMIT ISSUED: `� DATE COMPLIANCE ISSUED: VARIANCE GRANTED: Yes No �= �, o° � � � � � � --� �' „. O C `� �._