Loading...
HomeMy WebLinkAbout0200 HORSESHOE LANE - Health 200 HORSESHE LANE 'Centerville - A = 207 - 133 5 M EAe ft"am UPC 1=4 smssd mm • Us&In M AAN �'4r� t t EXCERPT FROM BOH MEETING MINUTES 7/8/08: (NOTE: W/DRAWN IN SEP) A. Rich Capen, Capewide Enterprise, representing Grazina Pileika, owner c :200 Horseshoe,Lane7Centerville^ Map/Parcel 207/133, 10,637 square feet lot, two variances for house addition. David Flaherty, Down Cape Engineering, represented the property for the owner and Rich Capen. David will submit the green cards to Mr. McKean tomorrow morning. There is one variance missing: the.septic is less than 100 feet from the wetlands with an increase in flow. Also, the setback variances are not correct for an increase in flow (only for a repaired system with the same flow) Upon a motion duly made by Mr. Sawayanagi, seconded by Dr. Canniff, the Board voted to Continue to Sep 9, 2008 Board of Health Meeting. (Unanimously voted in favor.) (COMMENT.added in September: the final result: the applicant decided not to increase the flow, so no continuance was needed.) �a.-�- 23 DATE: !S E10 BARNsrAst.e. MASS v i �`�$ REC. BY Town of Barnstable SCHED. DATE: Board of Health 200 Main Street,Hyannis MA 02601 Office: 508-862-4644 Wayne A.Miller,M.D. FAX: 508-790-6304 Paul J.Cannitf,D.M.D. VARIANCE REOUEST FORM LOCATION S�S�D� �/� C&vk Property Address: Pl'v Assessor's Map and Parcel Number: 2o7llSize of Lot: l0 6,37 rT"Z Y Wetlands Within 300 Ft. Yes _ Business Name: No Subdivision Name: �" " APPLICANT'S NAME:T(,(/G�w W Aye �iV��N6 �lLJ ryh.0 Phone Did the owner of the property, authoriz6 you to represent hin or her? Yes _ No PROPERTY OWNER'S NAME CONTACT PERSON Name: ZLIN►Q" l L�t k� Name:���E� �1I(ItVC [Al'k Address:_ � � ,`�► ' Address: �/. 1L9r�0�LQ� G O!v/ ' J Phone: Phone: ��� VARIANCE FROM REGULATION(List Reg.) REASON FOR VARIANCE(May attach if more space needed) 310 CMJ2 5mrl"f r&W I'd �rapv�j��h�cs VW -A F V9 Z0'ivX U s wc" ao?*Tr t — 20 I NATURE OF WORK: House Addition ❑❑❑❑❑ House Renovation ❑ Repair of Failed Septic System Checklist (to be completed by office staff-person receiving variance request application) Please submit copies in 4 separate completed sets. Four(4)copies of the completed variance request form �( Four(4)copies of engineered plan submitted(e.g.septic system plans) Four(4)copies of labeled dimensional floor plans submitted(e.g.house plans or restaurant kitchen plans) Signed letter stating that the property owner authorized you to represent him/her for this request Applicant understands that the abutters must be notified by certified mail at least ten days prior to meeting date at applicant's expense (forTitle V and/or local sewage regulation variances only) Full menu submitted(for grease trap variance requests only) >C Variance request application fee collected(no fee for lifeguard modification renewals,grease trap variance renewals[same owner/leasee only], outside dining variance renewals[same owner/leasee only],and variances to repair failed sewage disposal systems [only if no expansion to the building proposed]) �j Variance request submitted at least 15 days prior to meeting date VARIANCE APPROVED Wayne Miller,Chairman NOT APPROVED Paul J.Canniff,D.M.D. REASON FOR DISAPPROVAL C:\Documents and Settings\decollik\Local Settings\Temporary Internet Files\oLK1\VARI�REQ.DoC t� �� l.Mir tel.(508)362-4541 939 main street rt 6a fax(508)362-9880 yarmouth port mass 02675 down cape engineefing, inc. structural design civil engineers &land surveyors Daniel A.Ojala,P.E.,P.L.S. Arne H.Ojala P.E.,P.L.S. Timothy H.Covell,P.L.S. land court June 25, 2008 Andrew R.Garulay,R.L.A. surveys Re: 200 Horseshoe Lane Centerville, MA site planning Dear Abutter: sewage system designs A public hearing has been scheduled for the Barnstable Board of Health to take action on a request for variances from Title 5 Regulations under 310 CMR 15.000 and Town of Barnstable Regulations for the subsurface disposal of sewage for the inspections proposed septic system at 200 Horseshoe Lane Centerville. The variances requested are as follows: permits Variances requested under Local Upgrade Approval 15.211(1): landscape Reduction in setback, SAS &Reserve to property line (10' to 5') architecture Reduction in setback, SAS & Reserve to Foundation(20' to 15') Said hearing will be held in the Selectman's Hearing; Room in Town Hall, 367 Main Street, Hyannis, July 8th, 2008, at 3:00 pm. Please check with the Health Department to confirm date and time. Sincerely, David D. Flaherty Jr., R.S. Down Cape Engineering, Inc. cc: Abutters file Barnstable Board of Health Mrs. Grazina Pileika J 52 Portage Road West Hartford, CT 06117 and 200 Horseshoe Lane Centerville, MA 02632 June 23, 2008 Mr. Richard Capen Capewide Enterprises 4507 Falmouth Road Cotuit, MA 02635 To Whom It May Concern: Please accept this letter as my proxy for Downcape Engineering to represent me before the Board of Health regarding our variance fora four bedroom septic system at 200 Horseshoe Lane in Centerville. Sincerely, • AbutterReport Page 1 of 1 Board of Health Abutter List for Map & Parcel(s): 1207133' Direct abutters(no set distance) and the properties located across the street. Total Count: 6 Close Map&Parcel Ownerl Owne.r2 Addressl Address 2 Mailing Country Deed CityStateZip KUHN, 207093 CHRISTOPHER P& PO BOX 1119 HYANNIS, MA USA C170416 HINCKLEY, 02601 PENELOPE 207119 GOMBAR,JOHN D& JOHN&BARBARA 775 MARSOPA DR VISTA,CA 92083 USA 12585/174 BARBARA A,TRS GOMBAR LIVING TR MASON DAVID AIR JIMERSON MICHAEL CENTERVILLE, 207121 & A 193 HORSESHOE LN MA 02632 12883/048 207132 BROSMAN, 190 HORSESHOE CENTERVILLE, USA 10847/011 ELIZABETH A LANE MA 02632 207133 PILEIKA,GRAZINA %PILEIKA,GRAZINA GRAZINA H PILEIKA 52 PORTAGE W HARTFORD, USA 7435/178 H&VYTAUTAS,TRS LIVING TRUST ROAD CT 06107 207134 FOGG, BEVERLY A 221 OLD COUNTY PO BOX 418 E SANDWICH, 22152/174 RD MA 02537 This list by itself does NOT constitute a certified list of abutters and is provided only as an aid to the determination of abutters.If a certified list of abutters is required,contact the Assessing Division to have this list certified.The owner and address data on this list is from the Town of Barnstable Assessors database as of 6/12/2008. http://www.town.bamstable.ma.us/arcims/appgeoapp/AbutterReport.aspx?type=BOH 6/12/2008 Town of Barnstable �F ZNE Tp� Board of Health B" S MASS. ' 200 Main Street - Hyannis MA 02601 y Mnss. i639• ACED N1A'�A Agreement to Extend Time Limit for Acting Upon a Variance Request In the Matter of a variance request form received on '^-� a ZS the Petitioner(s), �(PL s -far- regarding the property at .200 ldihZan � y the petitioner(s)and the Board of Health agree that the Board of Health has until 020 o (insert date)to act upon the Petitioners'completed application for a variance. In executing this Agreement, the Petitioner(s) hereto specifically waive any claim for a constructive grant of relief based upon time limits applicable prior to the execution of this Agreement. Petitioner(s): Board of Health: Signature: Signature: Pe (e�r(s or Petitioner's Repre nt a Chairman Print: l.o 'J• �. Print: Wayne Miller, M.D. Date: 7A 6 t- Date: Address of Petitioner(s)or Petitioner's Representative Town of Barnstable Board of Health Public Health Division 200 Main Street Hyannis, MA 02601 Phone: (508) 862-4644 Fax: (508) 790-6304 file q:extend.doc .I I, I i i i V 17N Uj spa. m. _ � • � � � nacm ro 'I C -z- • N II N EXISTING BASEMENT EXISTING FLOOR FLOOR PLAN PLAN I EXISTINGING �'- FLOOR PLANS off 508-3 fax 508 362-9881 2-9880 Scale:1 = 10 b . 200 HORSE3�HOE- LANE down cape en gin eerin g, inc. 0 5 10 15 20 25 FEET CEN TER ✓ l L L Ep M/q L l VlL ENGINEERS AND SURVEYORS �! 939 Main Street — YARMOU THPOR T, MASS. DCE #08-042 1 .I. � � � I DECK SUN ROOM NEW DECK yea,ixa iea,iaa � .. 3 xcwva, ae Cfl n�n`in�:n� F SHOWER . BATH ROOM N _ rasa wmaemc ocm ar . s 1 a. € �.a.�za ❑ /11Mca" O cr h NEW HALF BATH F� _ — me a ~ t ^F NEW DINING KfTCHEN u ' 0 r___ me rcvrnia BEDROOM O O m El Eor- ❑ —_ N y� .mrmror,>w.vc rnruiec i iw,xna 4. G„ A PAMILY RDOM ROBED OM ONEW MASTER O �@ LIVING ROOM BEDROOMBED ROOM f � n�Mra APPROVED 15T FLOOR PLAN. . . . Reo5ed 4.7.05 relocated 5talr to I. 2nd floor deck PROPOSED 2ND FLOOR PLAN REVI5ED 4-7-08 5talr to deck relocated r I .. 1 i1i + �I off 508-362-4541 PROP OSED FLOOR PLANS fox 508 362-9880 S° - ' 200 HORSL�—SHOE- LANE down cape engineering,e en in e erie , inc. 0 5 10 15 20 25 FEET CEN TER I/l L L E� MACl�//L ENGINEERS LAND SURVEYORS DCE #OS-042 ;t 939 Main Street — YARMOUTHPORT, MASS. ALL S`(STEM SHALL OMPONE SYSTEM PROFILE MARKED WITHCMAGNETIC TAPE OR BE NOTES (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. 1. DATUM IS APPROXIMATE NGVD ACCESS COVERS TO WITHIN 6" OF FIN. GRADE PROVIDE INSPECTION PORT;TO WITHIN 3" OF FINAL GRADE (SEE VENT NOTE ON PLAN) 2. MUNICIPAL WATER IS EXISTING \ TOP FOUND. EL. 24.8' 23.3' 2% SLOPE REQUIRED OVER SYSTEM 24.0' 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. I MINIMUM .75 OF COVER OVER PRECAST (�� 4. DESIGN LOADING FOR SEPTIC TANK TO BE PRECAST H-10 �! AASHO H-10. DBOX AND CHAMBERS H-2-0. locus RISERS (TYP.) 2'0 4"OSCH40 PVC 2" DOUBLE WASHED PEASTONE { �'{ PIPES LEVEL 1ST 2' I 5. PIPE JOINTS TO BE MADE WATERTIGHT.OR GEOTEXTI E FABRIC w }- 21.0 \*22.19 10» 1500 GAL H-10 14» .� 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE a WITH � Horseshoe Ln 21.33' TEE SEPTIC TANK TEE \21.08'f ° ° o'° oo o �0 310 CMR 15.000 (TITLE V.) QL ° ° ° ° ° ° GAS BAFFLE..,' °°°o°o°o°o°o 0 20.5 3 AT SIDES ,_°°°„o ° °_ 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND 2.25' AT END NOT TO BE USED FOR LOT LINE STAKING OR ANY 4' LIQ. LEVEL (ACME OR EQUAL 20.71' 20.54' �$0 2 0 o0 0 000 18.5 OTHER PURPOSE. Oc oa ° ':,... ...._..;..,:•, - : , .:.• ::...,•..: : Ong °o°o°°o°o°o°000°o°o°°°o°°°o°o°o°°°o°o°o°°°°° " e °°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°o001 4, °,°o°.�_�_�_�_� ° ° o o ° 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4 PVC. DEPTH ES FLOW = �' 3/4" TO 1 1 2" DOUBLE WASHED STONE 9. COMPONENTS NOT TO BE BACKFILLED OR Nantucket 00 TEE SIZES: 6" CRUSHED STONE OR MECHANICAL / CONCEALED WITHOUT INSPECTION BY BOARD OF Sound INLET DEPTH = 10„ COMPACTION. (15.221 [2]) o HEALTH AND PERMISSION OBTAINED FROM BOARD OUTLET DEPTH = 14" 06 OF HEALTH AND OWNER'S ENGINEER. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP CALLING DIGSAFE (1-888-344-7233) AND ( 2.5% SLOPE) (0•5 % SLOPE) ( 1 % SLOPE) 10.5' BOTTOM TH-3 VERIFYING THE LOCATION OF ALL UNDERGROUND & SCALE 1"=2000'f NO GROUNDWATER FOUND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF LEACHING WORK. ASSESSORS MAP 207 PARCEL 133 FOUNDATION 20' SEPTIC TANK 53' D' BOX 3' FACILITY 11. ANY UNSUITABLE MATERIAL ENCOUNTERED LOCUS IS WITHIN FEMA FLOOD ZONE "C" LEGEND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL SHALL BE REMOVED 5' BENEATH AND AROUND THE AS SHOWN ON COMMUNITY PANEL #250001 0008 D PROPOSED LEACHING FACILITY. DATED JULY 2, 1992 UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 99- EXISTING CONTOUR PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 12. EXISTING LEACHING FACILITY SHALL BE PUMPED LOCUS IS WITHIN AP OVERLAY DISTRICT X say Exlsr. SPOT ELEV. AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. PROPOSED CONTOUR SETBACKS: REQ. PROP. 11-11 PROPOSED SPOT EL TEST HOLE LOGS VARIANCES WF #78 FRONT: 20' 30.7' THi 0 TEST HOLE LOCAL UPGRADE APPROVAL- SIDE 10' 17.6' 2x SLOPE OF GROUND ENGINEER: ' 310 CMR 15.21 1 (1):DAVID FLAHERTY R.S., SE2755 5p REAR 10' 40.7' unary POLE MINIMUM SETBACK DISTANCE FROM WF #7s WITNESS: DONNA MIORANDI, R.S. FIRE HYDRANT PROPERTY LINE TO SYSTEM SYSTEM DESIGN. mm-NOT ALL mms'my I"°�"'MN0 DATE: MARCH 7, 2008 FROM 10' TO 5' (SAS & RESERVE) PERC. RATE _ < 2 MIN/INCH MINIMUM SETBACK DISTANCE FROM FOUNDATION TO SYSTEM GARBAGE DISPOSER IS NOT ALLOWED '� �,� I ' TO 15.0' (SAS & RESERVE) \ a wF DESIGN FLOW:#80 4 BEDROOMS ® 110 GPD = 440 GPD CLASS SOILS p# 12127 FROM 20 _ \ELEV. ELEV. 6 1 �o USE A 440 GPD DESIGN FLOW ___-- � � 2 0" 24.0' 0" � 23.5' 1-7 WF #81 SEPTIC TANK: 440 GPD (2) = 880 A USE A 1500 GAL. SEPTIC TANK LS LS 9 � ,��, #82 1OYR 3/2 1OYR 3/2 17 - LEACHING: 8" g" �g 2� SIDES: 2 (40 + 10.3) 2 (.74) = 149 GPD B B 19 WORK\ r 0'1 �� BOTTOM 40 x 10.3 (.74) = 304 GPD a \vti LS LS s - FLOODZONE TOTAL: 612 S.F. 453 GPD 'o. 21 TH-4 J-e L A10 (EL. 11) 10YR 5/6 22 3' 10YR 5/6 20" \ 20" 21.3 s PROVIDE VENT WITH USE (5) H-20 "3050" INFILTRATORS IN A TRENCH CONFIGURAT 0 �' \O CHARCOAL FILTER o. Nw 144r , WITH 2.25 STONE AT ENDS AND 3, AT SIDES AND BUGSCREEN (FINAL PLACEMENT 3 VE 2 •0' �1 \ � SER C C WITH HOMEOWNER _ _ �p0�►,RE ti� �� CONSULTATION) TH-2 2, O PERC P \ MS MS ,= 2 �� 2.5Y 7/4 2.5Y 7/4 \\ o ,'.:z. 's o \ MA ROPOSE 132,� 13.0 120 13.5 \ `� ;,. y a \ � SUN ROOM 23 \ APPROVED DATE BOARD OF HEALTH PROPOSED DE K • c' j NO GROUNDWATER ENCOUNTERED \ ' ' '�`' EXISTING 3 BR \ : DWELLING E 9 ELEV. ELEV. \ TOP OF FNDN. , e TITLE 5 SITE PLAN EL. 24.8' 0" 21.5' 0" 21.5' \ O �. PROP. 4 ER I 1� OF \ O. (PROP. 2ND FLOOR OVER 10 37f SF 200 HORSESHOE LANE c, LOT 29 o \ S FOOTPRINT) G FILL FILL (CENTERVILLE) BARNSTABLE, MA 48" A B MIX 48" A B MIX \\ V 11��e PREPARED FOR /LS /Ls \\ /G CAPEWIDE ENTERPRISES/ „ 1 OYR 4/4 16 5' " 1 OYR 4/4 16 9' �0 \\ /G GRAZINA PILEIKA 60 55 \ �, \ BENCH MARK - CORNER OF \ N CONC. BULKHEAD EL. = 23.15 DATE: MAY 28, 2008 off\ 508-362-4541 C C \\ �tr OF M �LZH f fax 508-362-9880 o ygss PERC ASS9cq�� I downcape.com MS Ms a� DANIELA. y�� �� OANIEL �m down cope engering Inc 2.5Y 7/4 2.5Y 7/4 0 ine � OJALA NO ALA , ' 132" 10.5' 132" 10.5' clviL 4 �0 4 civil engineers NO GROUNDWATER ENCOUNTERED Scale:1"= 20' �o� �sTE��° �qti � von¢ �.. land Surveyors 512$��a 939 Main Street ( R to 6A) DATE DANIEL A. OJIALA, P.E., P.L.S. YARMOUTHPORT MA 02675 LICE #08-042 0 10 20 30 40 50 FEET 08-042 CAPEWIDE_PILEIKA.DWG (DDF)