THIS FORM IS A FACSIMILE OF THE STANDARD SEPTIC INSPECTION FORM ISSUED BY THE MASSACHUSETTS DEPARTMENT
OF ENVIRONMENTAL PROTECTION(revised 6/15/2000)
TITLE 5
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION
Property Address: 175 Monomoy Circle
Centerville
Owner's Name: Theresa Iamelle
Owner's Address: P.O.Box 134 RECEIVED
Centerville,MA 02632
Date of Inspection: May 6, 2004 MAY 112004
Name of Inspector: (Please Print) David D. Coughanowr,R.S.
Company Name: Eco-Tech Environmental TOWN OF BARNSTABLE
Mailing Address: 43 Triangle Circle I HEALTH DEPT.
Sandwich,MA 02563
Telephone Number: (508)364-0894
CERTIFICATION STATEMENT:
I certify that I have personally inspected the sewage disposal system at this address and that the information reported
below is true,accurate and complete as of the time of the inspection.The inspection was performed based on my
training and experience in the proper function and maintenance of on-site sewage disposal systems. I am a DEP
approved system inspector pursuant to section 15.340 of Title 5(310 CMR 15.000).The system:
X Passes
Conditionally Passes
Needs Further Evaluation By the Local Approving Authority
Fails
Inspector's Signature (�WA Date: MLY 61
The System Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or
DEP)within 30 days of completing this inspection.If the system is a shared system or has a design flow of 10,000
gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the
DEP.The original should be sent to the system owner and copies sent to the buyer,if applicable,and the approving
authority
NOTES AND COMMENTS
Inspector's Note—> A septic system is deemed to pass this Real Estate Transfer Inspection if it does not trigger
any of the failure criteria listed below. The septic system has been evaluated according to the conditions observed
on the day it was inspected. No estimate or guarantee of system longevity is made or implied by a passing determination.
****This report only describes conditions at the time of inspection and under the conditions of use at that
time.This inspection does not address how the system will perform in the future under the same or different
conditions of use.
Title 5 Inspection Form 6/15/2000 page 1
Page 2 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
INSPECTION SUMMARY: Check A,B,C,D or E/ALWAYS complete all of section D:
A] System Passes:
Yes I have not found any information which indicates that any of the failure criteria described in 310 CMR
5.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below.
COMMENTS:
B] System Conditionally Passes:
One or more system components as described in the"Conditional Pass" section need to be replaced or
repaired.The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass.
Answer yes,no, or not determined(Y,N,or ND). in the_for the following statements.If"not determined"please
explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not),is structurally
unsound,exhibits substantial infiltration or exfiltration,or tank failure is imminent. System will pass inspection if the
existing tank is replaced with a complying septic tank as approved by the Board of Health.
*A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance
indicating that the tank is less than 20 years old is available.
ND explain:
Observation of sewage backup or breakout or high static water level in the distribution box is due to broken or
obstructed pipe(s)or due to a broken,settled or uneven distribution box. The system will pass inspection if(with
approval of Board of Health).
broken pipe(s)are replaced
obstruction is removed
distribution box is leveled or replaced.
ND explain
The system required pumping more than four times a year due to broken or obstructed pipe(s).The system will
pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
ND explain
2
Page 3 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
C) Further Evaluation is Required by the Board of Health:
Conditions exist which require further evaluation by the Board of Health in order to determine if the system
is failing to protect public health, safety and environment.
1 System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the
system is not functioning in a manner which will protect public health,safety and the environment:
Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
2) System will fail unless the Board of Health (and public water supplier,if any) determines that the
system is functioning in a manner that protects the public health,safety,and environment
The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a
surface water supply or tributary to a surface water supply.
The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply.
The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well.
The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a
private water supply well**.Method used to determine distance
**This system passes if the well water analysis,performed by a DEP certified laboratory, for coliform
bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and
the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other
failure criteria are triggered. A copy of the analysis must be attached to this form
3)OTHER
3
Page 4 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 175 Monomov Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
D)System Failure Criteria applicable to all systems:
You must indicate either"yes"or"no"to each of the following for all inspections:
I have determined that one or more of the following failure conditions exist as described in 310 CMR 15.303.
The basis for this determination is identified below. The Board of Health should be contacted to determine what
will be necessary to correct the failure.
yes no
X Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool.
X Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or
clogged SAS or cesspool.
X Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or
cesspool.
X Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow.
X Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).Number
of times pumped
X Any portion of the SAS,cesspool or privy is below high groundwater elevation.
X Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface
water supply.
X Any portion of a cesspool or privy is within a Zone 1 of a public well
X Any portion of a cesspool or privy is within 50 feet of a private water supply well
X Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water
supply well with no acceptable water quality analysis.(This system passes if the well water analysis,
performed by a DEP certified laboratory, for coliform bacteria and volatile organic compounds
indicates that the well is free from pollution from that facility and the presence of ammonia
nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria
are triggered. A copy of the analysis must be attached to this form)
No (Yes/No)The system fails. I have determined that one or more of the above failure criteria exist as
described in 310 CMR 15.303,therefore, the system fails.The system owner should contact the Board of
Health to determine what will be necessary to correct the failure.
E)Large Systems:
To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000
gpd
You must indicate either"yes" or"no"to each of the following:
(The following criteria apply to large systems in addition to the criteria above)
yes no
the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped
Zone II of a public water supply well.
If you have answered "yes" to any question in Section E the system is considered a significant threat,or answered
"yes" in section D above the large system has failed.The owner or operator of any large system considered a
significant threat under section E or failed under section D shall upgrade the system in accordance with 310 CMR
15.304.The system owner should contact the appropriate regional office of the Department.
4
Page 5 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
Check if the following have been done: You must indicate either"Yes" or"No"as to each of the following:
Yes No
Y _ Pumping information was provided by the owner,occupant or Board of Health.
N Were any of the system components pumped out in the last two weeks?
Y _ Has the system received normal flows in the previous two week period?
N Have large volumes of water been introduced to the system recently or as part of this inspection?
Y _ Were as built plans of the system obtained and examined?(If they were not available as N/A)
Y _ Was the facility or dwelling inspected for signs of sewage back-up?
Y _ Was the site inspected for signs of breakout?
including
Y _ Were all system components,exeludin the SAS. located on site?
Y Were the septic tank manholes uncovered,opened,and the interior of the septic tank inspected for
the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of
scum.?
Y _ Was the facility owner(and occupants,if different from owner)provided with information on the proper
maintenance of subsurface disposal systems?
For information on the proper maintenance of subsurface disposal systems please go to:
WWW.ECO-TECH.US
The size and location of the Soil Absorption System(SAS)on the site has been determined based on:
Y _ Existing information.For example,Plan at the Board of Health.
Y _ Determined in the field(if any of the failure criteria related to part C is at issue,approximation of distance
is unacceptable) [310 CMR 15.302(3)(b)]
5
Page 6 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6,2004
FLOW CONDITIONS
RESIDENTIAL
Number of bedrooms(design): n/a Number of bedrooms(actual): 2
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): n/a—No plan on file at Health Dept.
Number of current residents 1
Does the residence have a garbage grinder(yes or no): Yes—removal of garbage grinder is strongly recommended.
Is laundry on a separate sewage system(yes or no): no :(If yes, separate inspection required)
Laundry system inspected (yes or no): n/a
Seasonal use(yes or no): no
Water meter readings,if available(last two year's usage(gpd): 97 gpd
Sump Pump(yes or no): no
Last date of occupancy: current
COMMERCIAL/INDUSTRIAL:
Type of establishment:
Design flow(based on 310 CMR 15.203):: gpd
Basis of design flow(seats/persons/sqf/etc.):
Grease trap present: (yes or no)_
Industrial waste holding tank present: (yes or no):
Non-sanitary waste discharged to the Title 5 system: (yes or no).
Water meter readings,if available:
Last date of occupancy/use:_
OTHER: (Describe):
GENERAL INFORMATION
PUMPING RECORDS
Source of information: System not pumped in recent past(Owner)
Was system pumped as part of the inspection: (yes or no) No
If yes,volume pumped: gallons--How was quantity pumped determined?
Reason for pumping:
TYPE OF SYSTEM:
X Septic tank,distribution box, soil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system(yes or no)(if yes,attach previous inspection records,if any)
Innovative/Alternate technology. Attach a copy of the current operation and maintenance contract(to be
obtained from system owner)
Tight Tank Attach a copy of the DEP approval
Other(describe)
APPROXIMATE AGE of all components,date installed(if known)and source of information:
Age: 27+years Certificate of Compliance issued 8/6/76 (BOH permit#228-76)
Were sewage odors detected when arriving at the site: (yes or no) no
6
Page 7 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6,2004
BUILDING SEWER_(Locate on site plan)
Depth below grade: 2 ft
Material of construction:_cast iron X 40 PVC other(explain)
Distance from private water supply well or suction line 20+
Comments: (on condition of joints,venting,evidence of leakage, etc.)
Sewer is vented through roof and appears structurally sound with no evidence of leakage or backup into dwelling_
SEPTIC TANK:Yes (locate on site plan)
Depth below grade: 15 inches
Material of construction: X concrete_metal_fiberglass_polyethylene
other(explain)
If tank is metal,list age_ Is age confirmed by Certificate of Compliance_(yes or no):_(attach a copy of
certificate)
Dimensions: 8.5 ft x 5 ft x 5 ft(1000 gallon)
Sludge depth: 18 in
Distance from top of sludge to bottom of outlet tee or baffle: 16 in
Scum thickness: 8 in
Distance from top of scum to top of outlet tee or baffle: 6 in
Distance from bottom of scum to bottom of outlet tee or baffle: 10 in
How dimensions were determined: Probe to top of tank
Comments: (on pumping recommendations,inlet and outlet tee or baffle condition, structural integrity, liquid levels
as related to outlet invert,evidence of leakage,etc.):
Pumping recommended at this time and maintenance pumping is recommended every 2 years. Liquid level at
outlet invert.Tank and tees appear structurally sound and functioning as intended.No evidence of leakage in or out.
GREASE TRAP: none (locate on site plan)
Depth below grade:
Material of construction:_concrete_metal_fiberglass_polyethylene
other(explain)
Dimensions:
Scum thickness:
Distance from top of scum to top of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle:_
Date of last pumping:
Comments: (on pumping recommendations,inlet and outlet tee or baffle condition, structural integrity, liquid levels
as related to outlet invert,evidence of leakage, etc.):
7
Page 8 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
TIGHT OR HOLDING TANK: none (Tank must be pumped at time of inspection)(locate on site plan)
Depth below grade:
Material of construction:_concrete_metal _fiberglass_polyethylene_other(explain)
Dimensions:
Capacity: gallons
Design flow: _gallons/day
Alarm present(yes or no):_
Alarm level: _ Alarm in working order(yes or no):_
Date of last pumping:
Comments:(condition of inlet tee, condition of alarm and float switches, etc.)
DISTRIBUTION BOX: Yes (if present must be opened)(locate on site plan)
Depth of liquid level above outlet invert: at outlet inverts
Comments:(note if box is level and distribution to outlets is equal,any evidence of solids carryover,any evidence of
leakage into or out of box, etc.)
D-box appears structurally sound with no evidence of leakage in or out.Effluent level at outlet inverts.
Some solids in tank.
PUMP CHAMBER: none (locate on site plan)
Pumps in working order: (yes or no)
Alarms in working order: (yes or no)
Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.):
8
Page 9 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
SOIL ABSORPTION SYSTEM(SAS): Yes (locate on site plan;excavation not required)
If SAS not located,explain why:
Type:
_leaching pits,number
_leaching chambers,number
_leaching galleries,number
_leaching trenches,number,length
X leaching fields,number,dimensions 2' x 30'
_overflow cesspool,number
—innovative/alternate system Type/name of Technology
Comments: (note condition of soil, signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.)
Soils above leachingfi eld appeared unsaturated. No evidence of surface ponding,breakout,lush vegetation,or
other evidence of hydraulic failure was observed. An observation hole dug into leaching field showed no level of
standing effluent. Stone showed no effluent contact staining.
CESSPOOLS: none (cesspool must be pumped at time of inspection)(locate on site plan)
Number and configuration:
Depth-top of liquid to inlet invert:
Depth of solids layer:
Depth of scum layer:
Dimensions of cesspool:
Materials of construction:
Indication of groundwater inflow(yes or no):
Comments: (note condition of soil, signs of hydraulic failure,level of ponding,condition of vegetation,
etc.):
PRIVY: none (locate on site plan)
Materials of construction:
Dimensions:_
Depth of solids:
Comments(note condition of soil, signs of hydraulic failure,level of ponding,condition of vegetation, etc.):
9
i
Page 10 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6,2004
SKETCH OF SEWAGE DISPOSAL SYSTEM:
Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or
benchmarks.Locate all wells within 100'(Locate where public water supply enters the building)
LOCATIONS
SEPTIC
TANK A B C
20 °� 1 27 ft 27.5 ft
❑ D-BOX 2 31.5 f t 33 ft
3 3 24 ft 37.5 ft
6 A
LEACHINGFIELD EXISTING
DWELLING
# 175
T
Z
J
W
W
Q
3
1
MONOMOY CIRCLE NOT TO SCALE
10
Page 11 of 11
OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 175 Monomoy Circle
Centerville
Owner: Theresa Iamele
Date of Inspection: May 6, 2004
SITE EXAM
Slope
Surface water
Check Cellar
Shallow wells
Estimated Depth to ground water: 12+ feet
Please indicate(check)all methods used to determine high ground water elevation:
Obtained from system design plans on record-If checked. date of design plan reviewed
Observed Site(abutting property/observation hole within 150 feet of SAS)
Checked with local Board of health-explain:
_ Checked local excavators, installers-attach documentation)
X Accessed USGS database
You must describe how you established the high ground water elevation.
Barnstable GIS department records indicate that property is over 12 feet above groundwater table.
11
�1
Coe
LOCQ N W
O,C,E PERMIT k10.
� SE
l — — — —
iWSTQL R tva E 6, ADDRESS
BUILDER 'S 1.1 lY E &.DORE SS
Dt.\TE PERMIT 155UED '—t�r
DATE COMPLI &MCE ISSUED ; 1�
�4 s
No � . ���-�'�'----'
�
THE COMMONWEALTH ormAssAo*usETrs �
BOARD F HEA TH
-- --'��F-..��� ----.
'
��� ^�
' ���o��loroo^ u� ��«� ���� u»
�� q� i«oul Workii Towitriartww*v Pumit
�
Application is hereby made for a Permit to Construct or Repair mb i6val Sewage Disposal
System 4:
---' -- .... ...... ' -.--__------'------
"=_---_ _-__-'-'-------'-'_'- -----.---_--------'
-- Address
.......... wner
�,� ' .
.-_-�--- -----~____-__--__----.-'-__----.-'---' --_--- ��S:izeLo7t
.. ............
~Tyye o6Dn3diug . ------.-Sg. feet
Dwelling--No. of Bedrooms--------...................................Expansion Attic / \ Garbage Grinder ( )
� Other—Type of Building ---------.- No. ofyc000s-------.--. Showers ( ) -- Cafeteria ( )
� 0ther6xt
Septic Tank
Other Distribution box ( ) Dosing.tank ( ) 0��� - ^--- ^ - - ~ ~
'- 9crooatioun Test Results Performed by---------------- Date----------------------------------------
Test Pit No. l................minutes per inch Doycb of Test Pit-------------------- Depth to ground water... ------
Ico Pit No per inch Depth of Icu �--__-_� � . Depth to
ground water.----`---
� �
� ~.~�~~ ~ ~~^ _
{}
-------'—'--------------'--'----------------------'---------------
Agrcooxen1:
The undersigned ugrccy to install the uforcdeooribed Individual Sewage Disposal System in accordance with
the provisions of Article XIof the State Sanitary Cod —Tbcuodersigned further agrees not to pl e the syste in
operation ou6\ a Certificate of Compliance
----- '' -----
. Application Approved 8 '��. -
^^ ""e
_- for thx rxoxomx:--------��------_----_----__----'-_-'---
. . .. . . .. . . . .. .. .. .. . . . '... .. . .. .. . ' .. . .. .. . .. . . .. . . .. . . . ' ....
Date
PermitNo......................................................... Issued.......................................................
Date
--''__--'' -'-_---' - - '- -
No................... '. Fss...., t 1.................
THE COMMONWEALTH OF MASSACHUSETTS
_ BOARD OF H EA l,_.T H
t .. .....OF........ - :h.G- - ...`.. ...................
Apphration -fur Uhipoiial Workii Tonstrurtiou Vrrmit
Application is hereby made for a Permit to Construct ( ) or Repair ( ) an Individual Sewage Disposal
System at ? �%
•-----------•..............•.---•••------•.._. ...
<7-Location- fdilress or I.o -off;; Owner Address
J`
Installer r J Address
UType of Building ✓ Size Lot............................Sq. feet
Dwelling—No. of Bedrooms-----------..............................Expansion Attic ( ) Garbage Grinder ( )
aOther—Type of Building -_---------------•--------- No. of persons............................ Showers ( ) — Cafeteria ( )
Otherfixtures ---•------------------•--••--------•------•••--------------------------------------------•--------•-----•----•------•---•----------------------------
W Design Flow............................................gallons per person per day. Total daily flow............................................gallons.
WSeptic Tank—Liquid capacity------------gallons Length---------------- Width................ Diameter---------------- Depth----------------
x Disposal Trench—No. ._/-------------- Width...........
Total Length....... __v-_--- Total leaching area- - ft.
Seepage Pit No--------------------- Diameter__-_-_ 0'___ Depth below inlet___________...__.._. Total leaching area..---_--._.___--sq. ft.
z Other Distribution box ( ) Dosing tankS—
aPercolation Test Results Performed by---- -------- ............................................................ Date----.-----•----------------------------
Test Pit No. 1----------------minutes per inch Depth of Test Pit.................--- Depth to ground water......---------.-..-----
G4 Test Pit No. 2................minutes per inch Depth of Test Pit-------------------- Depth to ground water-----------..-.------...
0 ----• ^ ----
O Descri -----_------
Description of Soil `� ii
� - -- �"epr ---- c
^r
------------- ----------------------------- . ..- G���1 � fih/ --� 0
U Nature of Repairs or Alterations Answer when applicable----------------------------
----------- ------------------------------------------------------------------------------------------------------------------------------ --------------------------------------------------- ---------
Agreement:
The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of Article NI of the State Sanitary Code—The undersigned further agrees not to place the syste in
operation until a Certificate of Compliance has been issuedbyV�the_ d of health.
.
Signe : rl�,c'� L/6,L
Date
Application Approved By------ = /-- --- --.----
Date
Application Disapproved for the following reasons----------------•-------------.......---------------------------------------------............----••......------.
--------•----•--••--•--•-----•--••••-•-----------------•-------•••--...-----------•-•--•---•-••-••----••---•--••---------•------•....-••-----•-•--------•--•-------------•--•-••-------------•---------
Date
PermitNo......................................................... Issued........................................................
Date
THE COMMONWEALTH OF MASSACHUSETTS
r--- BOARD O'F HEALTH
....... ............ .. . ...... .OF. .. ...... .. . . ----- .........Q.......
'T.,rrtif iratr of f11,1ampltanrr
THI I T RTI That the Individual Sewage Disposal System constructed ( 1�ror Repaired ( )
by ------ ----
/-- Ins er ,
S--
has been installed in accordance with the provisions of A Iss N�0�ie(,'Xate Sanitary Code as described in the
application for Disposal Works Construction Permit No. --. ---------------------------------- dated...-_--._-..-----_._-.___----...................
THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE
SYSTEM WILL FUNC IONS SFACTORY.
DATE Inspector csil'
-
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF EALTH
I
G ...........OF................. .... G %
No. •--•• FEE•--/ )------•--
�i�>��r�ttl �rk� (n.���tr�rti>�at �rrmit
Permission i .4,erfeby granted--------_--= y ----------- ----- ------- ................. .....................
to Constr ct or it Indiv' S a e Di osa] System
,j J
_.
at No. l -
Street
as shown on the application for Disposal Works Construction Permit No _- __-_ __-I____ , -ated_--- —... �-�____..._....
- ................
Board of Health
DATE.------6�.Y-74----
FORM 1255 HOBBS & WARREN. INC.. PUBLISHERS
1
G
7�o
15
d �
�Na O
fit:a,b
S ci�r t"!( �IrFZtJ
+,D sut�� L U j 7
C E QT V Q/► LL C 1 LA
G E'eri F y r414 7- r/-1,5
� iI V
ri✓:� �oc�ici,� G.QUJ� �� 7 i�� r'�j�U•V C]Ate'; 5"�Z/`7�