HomeMy WebLinkAbout0715 OLD STAGE ROAD - Health 715 Old Stage Road
A= 191 — 173
Centerville
5 M EAD
No.2-153LOR
UPC 12534
smead.com • Made In USA
FORUSED911NSpQOWU!E
Mann*soummWammum
CERTIFlED
SOURGraG W W W.SRWROGRIMIIORf
1
w
.,7.... Fics..... .. .-.
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
TOWN OF BARNSTABLE
Allpfi atiou for Diip.a ial 19orks Tiltuitrurtiun Frrmit
Application is hereby made for a Permit to Construct ( ) or Repair ( ,,�an Individual Sewage Disposal
System at: a'�tZ S--rio �
•--....._.7 V5........ ........................... ................................................... ------------------------------------------
Location-Address or Lot No.
.........v..0 ...............f.../! Gt `P_ 15. {tV.......c......................................................
W ................................
w. A^ Owner
Addre s ��
Installer Address
d Type of Building Size Lot.............................Sq. feet
U a Dwelling—No. of Bedrooms...__�..............................._..Expan
sion Attic ( ) Garbage Grander ( )
aOther—Type of Building ............................ No. of persons............................ Showers ( ) — Cafeteria ( )
d Other fixtures ----------------------------------------------------
•---------------------
W Design Flow..-_._._._..�?..Z:S ....................gallons per person per day. Total daily flow____----Z3.d......................gallons.
1:4 Septic Tank—Liquid capacity............gallons Length................ Width................ Diameter................ Depth................
x Disposal Trench—No..................... Width.................... Total Length.......:............ Total leaching area....................sq. ft.
Seepage Pit No.--____1---_-._____- Diameter-___- ....... Depth below inlet,.....6(--------- Total leaching area..................sq. ft.
Z Other Distribution box ( ) Dosing tank ( )
aPercolation Test Results Performed by-------------------------------• ................. Date........................................
Test Pit No. 1................minutes per inch Depth of Test Pit...._.............__ Depth to ground water.......................
44 Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................
9 -•-•---•-•--------------•----------••---••-••-•-•---------•-••---••--•••......•.....-------------•--.........................................................
0 Description of Soil.........................................................................................................................................................
x
W
--------- -
U Nature of Re airs or Alterations—Answer when applicable_.. 1aG_----------I�`-.1� �___-___-__l�'_ __ 4 .
f
Agreement:
The undersigned agrees.to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the
system in operation until a Certificate of Compliance has ben issued by the board of health.
Signed . -- -------------- -------------------------------------
Daze
Application Approved By - ''
< -
-------------------------------------------------------------------------------- --- I.. ...-..
Application Disapproved for the following reasons- ............................................ --------------------........------------------.------------1e-- ---..........
------------- -------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------- -------------------------------------
aDate
PermitNo. --------3?.7-----_---------_-------- Issued -------------------------------------------------------------------
Date
7.... Fxs.......... --••.
THE COMMONWEALTH OF MASSACHUSETTS-
� , i1 3 BOARD OF HEALTH
i TOWN OF BARNSTABLE
Apptiratiou for 11hipasal Works Tonotrnrtion rrmit
Application is hereby made for a Permit to Construct ( ) or Repair ( an Individual Sewage Disposal
System at: a\ S 6�pcJ� 4Q
... ` .:.. ;1` .._.... - ............................ .................:4 ..� ..........................................__ t ' -•- -Location-Address or Lot No.
.. ....
Owner Address 'jk
.......... e- -- G -------------•--•----•-------...-----•---
VA, Ph
Installer Address
Type of Building Size Lot----------------------------Sq. feet %
7Dwelling—No. of Bedrooms---: .................................Expansion Attic ( ) Garbage Grinder ( )
aOther—Typ'e of Building ------_--------------------- No. of persons._....._.................... Showers ( ) — Cafeteria ( )
Otherfixtures ---------------------- ....................................... .......-....................................................................
W Design Flow....._...` ....................gallons per person per day. Total daily flow------_ - .......................gallons.
WSeptic Tank—Liquid capacity............gallons Length................ Width-----_........._ Diameter----------...... Depth................
x Disposal Trench—No....m................ Width....._.............. Total Length.................... Total leaching area....................sq. ft.
Seepage Pit No........1_........... Diameter..... ..... Depth below inlet.....(n t_._..__.. Total leaching area..................sq. ft._
Z Other Distribution box ( ) Dosing tank ( )
aPercolation Test Results Performed by.......................................................................... Date.........................."............
Test Pit No. I................minutes per inch Depth of Test Pit.................... Depth to ground water....................
Lit Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................
...............---...................................................................................-•----------------------------------......__...........
0 Description of Soil...............................................................................:...............-........................................................................ a
x
U ----------•--•-••------------••----------------••------------•----------------------------•...----------•----------••--•--•----.......--------••-=-•---••-•••----•-••--•----------•----•---------•-----
w
x ---- ---------------------------------••-----•-•----------•-•-•---- ................................-----•---•------------ .............................................................U Nature of Repairs or Alterations—Answer when applicable_.._ CSC 0-_f 1.......... ................10.. (................. ....... .......... .......................................................
Agreement:
Thefllundersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with
the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the
system in operation until a Certificate of Compliance has been issued by the board of health.
Signed � ... - -------- -------------------------------------
Date
Application Approved By .
Date
Application Disapproved for the following reasons: ------.... ...... ....................................... .................
........
Date
Permit No. ---------..m------------- Issued ------ ------.__
Date
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
TOWN OF BARNSTABLE
Cer#tft.cate of Tamplinifre
THIS IS TO CERTIFY, That the Individual Sewage Disposal System constructed ( ) or Repaired ( L-4-
by ----------------------- ........ ......... .......................................................
Insta er
at ----------------------------- -'�?��� �5-1.�-� ... ..._... .._....-...... ._......._...:....._..._-...-................
has been installed in accordance with the provisions of TITLE 5 of The State Environmental Code as described in
the application for Disposal Works Construction Permit No ...... ___ ..1r.7-<-N dated ......p J...................................
THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUA 4NTEE THAT THE
SYSTEM WILL FUNCTION SATISFACTORY.
DATE------- -.. _�------------------ ------------ _......... Inspector ..- /I.y t. .................
THE COMMONWEALTH OF MASSACHUSETTS
BOARD OF HEALTH
TOWN OF BARNSTABLE
./.� FEE... .....2...........
wisposal Works Tonstrudion rantit
Permission is hereby granted......-----.�"{ i -f ... �-6Z
to Construct ( ) or Repair (_ ) .,n Individual Sewage Disposal System
at No...............'1L.7 ........... Aa�...SA.N.I __.... G�.......
Street
11
as shown on the application for Disposal Works Construction Permit No. l1. . Dated..........................................
q ) d
DATE. ---------------------- Board of Health
FORM 36508 HOBBS 6 WARREN.INC..PUBLISHERS
A
r 1 TOWN OF BNSTABLE R
LOCATION �`J 1�, - SEWAGE #
VILLAGE���` ';��I ���L ASSESSOR'S MAP & LOT
INSTALLER'S NAME & PHONE NO.QOUC � �1�
'J
SEPTIC TANK CAPACITY O� la m
LEACHING FACILITY:(type) (size)
NO. OF BEDROOMS PRIVATE WELL OR PUBLI Ojwkff)(9) C WATER
BUILDER OR OWNER dL
DATE PERMIT ISSUED: 8-3
DATE COZIPLIANCE ISSUED:
VARIANCE GRANTED: Yes No
44 Groh-- I,-
.ILI q��
�(p - e x(e
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
"Y 715 Old Stage Road, Centerville M - 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue Mashpee MA 02649 August 12, 2014
page. Citylrown State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:when filling out forms A. General Information
on the computer, I
use only the tab 1. Inspector: /U lJl
key to move your I
cursor-do not Troy Williams
use the return key. Name of Inspector
Troy Williams Septic Inspections _
Company Name
19 Hummel Drive
Company Address
South Dennis MA 02660
Cltyrrown State Zip Code
(508) 385- 1300 S1682
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 16.340 of
Title 5(310 CMR 15.000).The system:
® Passes ❑ Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
�zt crt , J,,� August 12, 2014
Inspector's Signature Date
The system inspector shall submit a'copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
v I ✓
t5ins•3/13 Title 5 Official Inspection Form: 1 bs ace Sewage Disposal System•Page 1 of 17
t
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
"< 715 Old Stage Road, Centerville M-191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is 45 Pinecrest Avenue, Mashpee MA 02649 -August 12, 2014
required for every
page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
System meets minimum standards set by Massachusetts DEP at the time of inspection only.This
inspection is not a guarantee or warranty on the future working conditions of leaching, pipes,
components or the future structural integrity of said components and only represents conditions found
at the time of inspection only.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass"section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
*A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5ins-3/13 Title 5 official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is 45 Pinecrest Avenue Mashpee MA 02649 August 12 2014
required for every � 9 ,
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
B) System Conditionally Passes (cont.):
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
C) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
°f 715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
required for every
page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health(and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well".
Method used to determine distance:
**This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
3. Other:
D) System Failure Criteria Applicable to All Systems:
You must indicate"Yes" or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than %day flow
t5ins•3113 Title 5 Official Inspecfion Form:Subsurface Sewage Disposal System•Page 4 of 17
i
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer Go Susan Palermo POA
Owner Owner's Name
information is 9
required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
_
page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool-or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (interim Wellhead Protection
Area—IWPA)or a mapped Zone II of a public water supply well
If you have answered"yes"to any question in Section E the system is considered a significant threat,
or answered"yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. Cityrrown State Zip Code Date of Inspection
C. Checklist
Check if the following have been done. You must indicate"yes" or"no"as to each of the following:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
❑ ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
® ❑ Were as built plans of the system obtained and examined?(if they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner)provided with
information on the proper maintenance of subsurface'sewage disposal systems?
The size and location of the Soil Absorption System(SAS)on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable)[310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
Number of bedrooms(design): 3 Number of bedrooms(actual): 3
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 gpd
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is every 45 Pinecrest Avenue, Mashpee MA 02649 August 12 2014
required for eve 9
page. Cityrrown State Zip Code Date of Inspection
D. System Information
Description:
Number of current residents: 1
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system?(Include laundry system inspection [I Yes ® No
information in this report.)
Laundry system inspected? ® Yes ❑ No
Seasonal use? ❑ Yes ® No
Water meter readings, if available last 2 ears usage 13=32,000 gals.
g ( y g (gpd))' 12=38,000 gals.
Detail:
Sump pump? ❑ Yes ® No
Last date of occupancy: occupied
Date
Commercial/Industrial Flow Conditions:
Type of Establishment: N/A
Design flow(based on 310 CMR 15.203): N/A
Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.): N/A
Grease trap present? El Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available: N/A
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
required for every
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
N/A
Last date of occupancy/use: Date
Other(describe below):
NIA
General Information
Pumping Records:
Source of information: Last pumped on 6/12/02 per info from owner.
Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped: gallons
How was quantity pumped determined?
Reason for pumping:
Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology. Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
t5ins-3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road, Centerville M - 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed (if known)and source of information:
Tank and leach pit#1 are original to home. 2ntl pit was installed on 8/31/90 per compliance
Were sewage odors detected when arriving at the site? ❑ Yes ® No
Building Sewer(locate on site plan):
Depth below grade: 18"+
feet
Material of construction:
❑ cast iron ®40 PVC ® other(explain): sch 20 pvc
Distance from private water supply well or suction line: feet
Comments(on condition of joints, venting, evidence of leakage, etc.):
Flushed lines and found clear at the time of inspection.
Septic Tank(locate on site plan):
Depth below grade: it
feet
Material of construction:
®concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance?(attach a copy of certificate) ❑ Yes ❑ No
Dimensions: 5'X9'X6' 1000 gallon
Sludge depth:
4"
t5ins•3113 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 9 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank(cont.)
2,8„
Distance from top of sludge to bottom of outlet tee or baffle
lit
Scum thickness
Distance from top of scum to top of outlet tee or baffle
6"
Distance from bottom of scum to bottom of outlet tee or baffle
13"
How were dimensions determined? probe/measured
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Inlet baffle and outlet tee were found present and in working order. No evidence of leakage or
damage was found
Grease Trap(locate on site plan):
Depth below grade: N/A
p g feet
Material of construction:
❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions: N/A
Scum thickness N/A
Distance from top of scum to top of outlet tee or baffle N/A
Distance from bottom of scum to bottom of outlet tee or baffle N/A
Date of last pumping: N/A
Date
t5ins•3113 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 10 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade: N/A
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
Dimensions: N/A
Capacity: N/A
gallons
Design Flow: N/A
gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: N/A Alarm in working order: ❑ Yes ❑ No
Date of last pumping: N/A
Date
Comments(condition of alarm and float switches, etc.):
N/A
Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 11 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
"~ 715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
I
Distribution Box(if present must be opened)(locate on site plan):
I
Depth of liquid level above outlet invert
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
probed line with no original d-box found present.
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No*
Alarms in working order: ❑ Yes ❑ No*
Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.):
N/A
*If pumps or alarms are not in working order, system is a conditional pass.
Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
'l 715 Old Stage Road, Centerville M - 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Type:
® leaching pits number: 2-6'X6' pit with
2 of stone
❑ leaching chambers number:
❑ leaching galleries number:
❑ leaching trenches number, length:
❑ leaching fields number, dimensions:
❑ overflow cesspool number:
❑ innovative/alternative system
i
Type/name of technology:
Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
Leach pit#2 was found with 4'dry with a visible stain line approx. 2.5' below inlet invert. Leach pit#1
was found with water level approx. 1' below outlet invert. Pvc outlet tee present on outlet line. No
evidence of hydraulic failure or problems in the past were found at the time of inspection
Cesspools (cesspool must be pumped as part of inspection)(locate on site plan):
Number and configuration N/A
Depth—top of liquid to inlet invert N/A
Depth of solids layer N/A
Depth of scum layer N/A
Dimensions of cesspool N/A
Materials of construction N/A
Indication of groundwater inflow ❑ Yes ❑ No
t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
715 Old Stage Road Centerville M- 191 P-173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is Mashpee MA 02649 August 12, 2014
required for every 45 Pinecrest Avenue,
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
N/A
Privy(locate on site plan):
Materials of construction: N/A
I
Dimensions N/A
Depth of solids N/A
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
N/A
t5ins•3/13 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 14 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
"t 715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below:
® hand-sketch in the area below
❑ drawing attached separately
c.J<� �' I
I
I ' ,
� � I
a
0
a
o - ----------
A 1 - 93I
Irjrl
3
t5ins-3113 Tide 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is required for every 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
page. Cityfrown State Zip Code Date of Inspection
D. System Information (cont.)
Site Exam:
® Check Slope
❑ Surface water
® Check cellar
❑ Shallow wells
Estimated depth to high round water: 13.0'+
P g g feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
® Observed site(abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health-explain:
❑ Checked with local excavators, installers-(attach documentation)
® Accessed USGS database-explain: '
SDW 252 Zone C 47.2' 2.6'adjustment
You must describe how you established the high ground water elevation:
Hand augered 4' below bottom of leaching with no water found at a depth of 12.2'. Groundwater
adjustment at the time of inspection was 2.6'. Bottom of leaching at 8.2'was dry and found not to be
located in the high groundwater elevation at the time of inspection. USGS maps estimate
groundwater at approx. 30.0'
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5ins•3/13 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 16 of 17
Commonwealth of Massachusetts
Pal Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
715 Old Stage Road, Centerville M- 191 P- 173
Property Address
John Creamer c/o Susan Palermo POA
Owner Owner's Name
information is 45 Pinecrest Avenue, Mashpee MA 02649 August 12, 2014
required for every 9
page. Cityrrown State Zip Code Date of Inspection
E. Report Completeness Checklist
® Inspection Summary: A, B, C, D, or E checked
® Inspection Summary D(System Failure Criteria Applicable to All Systems)completed
® System Information—Estimated depth to high groundwater
®
Sketch of Sewage Disposal g posa System either drawn on page 15 or attached In separate file
0
t5ins-3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 17 of 17