Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0749 SOUTH MAIN STREET - Health (2)
749 South Main Centerville A = 185 - 012 - 001 §`4 'a 1 EEAd No.2-153LOR UPC 12534 emend com • Made In USA No. f�r:� 0?�C oo c Fee*L(4__ _ r THE COMMONWEALTH OF,MASSACHUSET{TS Entered in computer: / PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS Yes Rphration for Oiq gal *papm Congtruction 30ermtt Application for a Permit to Construct( ) Repair( ) Upgrade(•Abandon( ) [J Complete System ❑Individual Components Location Address or Lot No. 7gcj sp,�qj h b�., Owner's Name,Address,and Tel.No. Ce�,NV_ Re%vv, !✓.+ metc�e� Cr�.�n Assessor's Map/Parcel ,�e.� O Z ®0 WS3Slewa�)h Cwn1+y 1p AQr � Ft 3 Installer's Name,Addre s,and Tel.No o 8 �`3' 0 , fS, � , Designer's Name,Address and Tel.No. t.n - ��i'`�e S 08- s Type o Building: ` Dwelling No.of Bedrooms Lot Size sq.ft. Garbage Grinder Other Type of Building No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow(min.required) `Sy® gpd Design flow provided Ise gpd Plan Date , Z.�, 8 Number of sheets_1 Revision Date d; Title �eaXek \_1L \X a�� Size of Septic Tank Type of S.A.S. Ili-S'bl) G�` CkL�.1 �.� ��-�c1"A f Z.� Description of Soil 0—� , FA -33^44 " 6(k h;V- N`1 UAP 04M-1 A, ) -sz" C, c*wyl, loyk (p/d Inm S?-i3Z�� cZ IJ3` t-(2— z SY MF[) s0_,0 Nature of Repairs or Alterations(Answer when applicable) 3 �- i s,� v Date last inspected: r Agreement: m, tr. The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system ni acAdance with the provisions of Title 5 of the EnXionmeLual Code and not to place the system in operation until a Certif Cate o Compliance has been issued by this a of He thJ t - -- rn Date Application Approvec6yDate Application Disapproved by: Date for the following reasons Permit No. Date Issued G TOWN OF BARNSTABLE LOCATION 1-1101 S'T rLl6 SEWAGE# Zv0e' VILLAGE " t V)(,(b ASSESSOR'S MAP&PARCEL INSTALLERS NAME&PHONE NO. pAStorZ 81N SEPTIC TANK CAPACITY 3500 91 / Z500 q) PUMP LEACHING FACILITY:(type)500�) GH't"B-su (size)vlad3 y /3 NO.OF BEDROOMS �y OWNER /L.006 ; PERMIT DATE: �' "O f' COMPLIANCE DATE: Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet Private Water Supply Well and Leaching Facility.(If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist t within 300 feet of leaching facility) Feet FURNISHED BY z Ai 3 Z A3 �� 83 *Flu Aw Y9• f3 53 j oL rLc AS Q� '.-`�..,+..�-.,,•..�. .. '"'t't,y\ .� k '- - , /��. M1-e f Tv'.' �r..�7�/— rev♦"'✓-."�.,.ioW,ew1-e.. .t... .. '' °ia :. '�� *' `'^ ls+"� No. FAA QJ _Io�44_" THE COM ONWEAh�FWASSACHUSE rTS Entered in computer: .'4 A, w Yes PUBLIC HEALTH DIVISION - TOWN OFBARNSTABLE, MASSACHUSETTS, , ZIpprication. for Mi-5pp. lf-dip,5tem Conotruction Permit Application for a Perm t to Construct O Repair( )-Upgrade( Abandon( ) 2 Complete System ❑Individual Components Location Address or Lot No. -7qI e,0A'V\Oil\ ��V Owner's Name,Address,and Tel.No. Assessor's Map/Parcel 1$5 Z 00 w W�aktwurl�(u�nlr7kApa # �e Installer's Name,Address,and Tel.No. 8 f! �� Designer's Name,Address and Tel.No. ,Q f Type of Building: IDwelling • No.of Bedrooms h + Lot Size sq.ft. Garbage Grinder 40) � Other Type of Building No.of Persons Showers( ) Cafeteria( ) ' t Other Fixtures Design Flow(min.required) ISIA O gpd Design flow provided I gpd _ Plan Date ?Cyr, Number of sheets 1 Revision Date - .Ms Title SAC C., 17�,Da�ecJ� �e OIt�L �)OG-�'ctl—q— i Size of Septic'Tank 35M Type of S.A.S. jy-SOo 6 (��M��ao/ in fZ� EJ" N l ~, Description of Soil J�,, 1� IZ,o4tz (�-� F�11 ` (A gea _ JIDN I A*WV, 10\44- (P18 M1r7 to / ° , 1 �7-112 A,ir 2_ 7 S\4 �rrk n j�)_o Nature of Repairs or Alterations(Answer when applicable) Date last inspected: r J Agrepment The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accly,dance with the provisions of Title 5 of the Enviionme tal Code and not to place the system in operation until a Certificate of Compliance has been issued by this Board of Hea th. t=j �' a•gried ' T a 1/ it' Date Application Approve by �� Date - Application Disapproved by: ` Date for the following reasons a Permit No. pCrT Date Issued ————.————————————————————--— ————— THE COMMONWEALTH OF MASSACHUSETTS Ar PJ BARNSTABLE, MASSACHUSETTS s lea 7 Certificate of Compliance THIS IS TO CERTIFY,that the On-site Sewage Disposal System Constructed ( ) Repaired ( ) Upgraded (/) Abandoned( )by i cc at 56-1VN M4�n_ l�.Pn (utl{(I has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. c_',CW —(T dated Installer Designer #bedrooms 3 1 Approved design flow gpd The issuance of this permit shad notZv nstrued as a guarantee that the system will�fu crib, a�esigrned. ^� Date 3 Inspector tj \ --------------------------------------------- No. — IO I Fe'4110 THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION-BARNSTABLE, MASSACHUSETTS �} Migoal *pgtem Construction Permit Permission is hereby granted to Construct ( ) Repair ( ) Upgrade-(�) Abandon ( ) System located at ?,, 56Ah `J In s Cf114','11SO Q` and as described in the above Application for Disposal System Construction Permit.The applicant recognizes his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided: Construction (must be completed within three years of the de of this pe ih. Date �/0 Approvedb r'— Miorandi, Donna From: Miorandi, Donna Sent: Wednesday, October 22, 2008 4:19 PM To: McKean, Thomas Cc: Buntich, JoAnne Subject: 749 South Main St., Centerville Hello, Just a heads up that there is a meeting for this property with JoAnne Buntich on Monday, Oct. 27th at 11 am. Others attending are Tom Perry and the builder, CJ Riley. This is as you know in the DCPC and the builder and homeowner are looking to construct a rather large 4 car detached garage (dwelling)with much storage(???) above. Builder has presented NO floor plans for the storage area above garage. The owner thinks that down the road it may be a separate dwelling and they THINK they can just take bedrooms out of the existing and add bedrooms in the future to this detached garage. The existing house is already approved for 13 + 1 bedroom on the property. The one bedroom is in the BOATHOUSE. Just how many more bedrooms can this property support???? Donna'Miorandi f 1 Town of Barnstable Regulatory Services Thomas F.Geiler,Director sa Public Health Division Thomas McKean,DireOor 200-Main Street,.yanWs,MA 02601 Ofte; 5 6-362-4644 Faye: 508-790.6304 Deliggir, CaMhation Form Date: 161 0� Designer: 5offiVATJ N6► 1 R.11�tLS bnstailer: a .' xvAt Address: E 12 9*4 651 -- Address: P.q jjk:4 12.99 on 5 - 6,1 _— w r► was issued a permit to install a tc nsta cr) septic 9Y tens at "74 4 'Sam _ _ a,Rased on a design drawn by (address) suit IV dated /' -r!`d 9 -- esig$er I certify that the septic system reforen ed above was installed substantially according to t e des.ir, which may an. clude minor approved changes such as lateral relocation of the stribudon box and/or septic teak. .I certify that the septic system referenced above was installed with major changes (Le, ter tl= 10' lateral relocation of the SAS or any vertical relocation of any eompcmeirt o the septic system)but in accordance with Stare & Local Regulations. Plan rev4 wn wr. c 'tied as- h by desiper to follow. f •r P`MR ' SULLIVAN igztature) NO.294 3 ' p AL T1 isrier s3ignature (Affix esigner's Stamp ere WIL �T A.ND KRARNSTABLE-PMAUX . , Q•.f�e!akb/5 tia�exfp�er c�A++c£�cation Foam 60 39rld r JNI DNA NVAi—nns 5ZZ88Zb805 £E:OZ 800Z/ZZ/01 Message Page 1 of 4 C J Riley From: Buntich, JoAnne(Joann.buntich@town.barnstable.ma.us] Sent: Thursday, May 01, 2008 10:37 AM To: cjhley@cjriley.com Cc: Stanton, David; Daley, Patty; Perry, Tom;john@sullivanengin.com; Sara Alger; Weil, Ruth Subject: 195 Long Beach 749 and 767 South Main Hello Mr. Riley, 195 Long Beach -We have all reviewed the final plans stamped by the architect and have determined that the additions proposed are exactly 25% more than what was in place for that structure on July 1, 1989. ---�,%�749 and 767 South Main -We have reviewed the floor plans and application and understand that the only work proposed is an upgrade to the septic system. This system is designed to accommodate flows from the existing multi bedroom residence at 749 South Main and the 1 bedroom boathouse at 767 South Main. We understand that no bedrooms are being added to either structure and no structural additions or renovations for either structure are proposed at this time.Please let me know if you have any further questions or need more information. Please let me know if you have any further questions or need more information. Jo Anne Miller Buntich Assistant Director Growth Management Department Town of Barnstable 367 Main Street / Hyannis, MA 02601 t p 508 862 4.735 f 508 862 4782 joann.buntich__@town.barnstable_ma_us -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Wednesday, April 30, 2008 6:33 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main Jo Anne Per your request please find attached a floor plan of the existing boathouse, as well as photos- 1 from outside, 1 inside towards bathroom/entrance, 1 inside towards kitchen area, 1 from loft area, and 1 underneath. hope this helps with your determination. John O'Dea From:. Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 3:47 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main 5/1/2008 41-�d �1 ;up 1 X� d __- . 1 r . ., . - ,- ,: ,.: :� �;. ,,,r,� T ,: �. i f, Aida•. .� �'C_ S� k Ap Sri:) mv ro;r,4 d i t t _ _... . . . _ ' t _ ; i ;• 1 i 2 _ I a 7 : a t 1 r l t !^ r i r ; ! t t t i - - rr t N �V— 1 i , 11-4 ik l a , i f : _ 1 t a i t 1' s bw � � rt �3 f' 't � 1 6,601.79 eq R 'V rq PRE-1989 IMPERMEABLE 5 UA DOTAGE: 28x AVAILABLE LL ODITIONS: 3156 BF / ^ MAIN FOOTPRINT: 3,4665F POST-19891MPER ADDITION BOATHOUSE FOOTPRINL• 967 SF 967.0 e ft LANDSCAPE PAVING: 1,5126F POOL,ETC. \ -9746F I ENTRY PORTICO: 75 5F PROPOSED DECK COVERING -380 6F PAVED DRIVEWAY: i 6.602 SF TOTAL: 12,822 SF IMPERMEABLE SF AVAILABLE FOR GARAGE:1.802 SF I Stanton, David From: John O'Dea [John@sullivanengin.com] Sent: Wednesday, April 30, 2008 6:33 PM ��QS,,ky��]� To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' ( `"l 4 Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main Jo Anne Per your request please find attached a floor plan of the existing boathouse, as well as photos— 1 from outside, 1 inside towards bathroom/entrance, 1 inside towards kitchen area, 1 from loft area, and 1 underneath. I hope this helps with your determination. John O'Dea From: Buntich, JoAnne [ma ilto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 3:47 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main I'm glad I have that right. All we need now is the existing conditions plans for the boathouse which is located on a separate abutting lot and connected to the septic system. Once we have that we can make the final determination. Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich(d-)town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Monday, April 28, 2008 1:39 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main I believe that you are correct. We (Sullivan Engineering)specifically requested that the owner have existing floor plans prepared, so that we could use them to determine the design flow, and submit them (as required by the Board of Health)with the septic permit. Sometimes on simple/small houses we will do the existing floor plans ourselves, or have the owner do them, but this house was a little overwhelming. The plans were prepared by an architect. John O'Dea From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 12:14 PM 5/5/2008 To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. Let me see if I understand this correctly- • The"existing"floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. • That is why"proposed"floor plans were not submitted -because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 Joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:iohn(cDsullivanen in.com Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of"Bedroom". There for there are three"Bedrooms" in the basement (family room +2 adjacent rooms), three bedrooms on the first floor(bedroom + office + sunroom) (we made an executive decision to exclude the mudroom), and 7 on the second floor(6 bedrooms + sitting room). The boathouse is one open finished room. I believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. 5/5/2008 -----Original Message----- From: CJ Riley [mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 7:33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in,bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application?Thank you, C j Sent via BlackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>,"Sara Alger" <sfa@nantucket.net> Cc:"Weil, Ruth" <Ruth.Weil@town.barn stable.ma.us>,"Daley, Patty" <Patricia.Dal ey@town.barn stable.ma.us>,"Stanton, David" <David.Stanton @town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [mailto:ciriley(a cjriley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step?And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via BlackBerry by AT&T 5/5/2008 I t Stanton, David From: Buntich, JoAnne Sent: Thursday, May 01, 2008 10:37 AM To: cjriley@cjriley.com Cc: Stanton, David; Daley, Patty; Perry, Tom; 'john@sullivanengin.com'; 'Sara Alger'; Weil, Ruth Subject: 195 Long Beach 749 and 767 South Main Hello Mr. Riley, 195 Long Beach -We have all reviewed the final plans stamped by the architect and have determined that the additions proposed are exactly 25% more than what was in place for that structure on July 1, 1989. 749 and 767 South Main -We have reviewed the floor plans and application and understand that the only work proposed is an upgrade to the septic system. This system is designed to accommodate flows from the existing multi bedroom residence at 749 South Main and the 1 bedroom boathouse at 767 South Main. We understand that no bedrooms are being added to either structure and no structural additions or renovations for either structure are proposed at this time.Please let me know if you have any further questions or need more information. Please let me know if you have any further questions or need more information. Jo Anne Miller Buntich Assistant Director Growth Management Department Town of Barnstable 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 Joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Wednesday, April 30, 2008 6:33 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty; Perry,Tom Subject: RE: 749 south main Jo Anne Per your request please find attached a floor plan of the existing boathouse, as well as photos— 1 from outside, 1 inside towards bathroom/entrance, 1 inside towards kitchen area, 1 from loft area, and 1 underneath. I hope this helps with your determination. John O'Dea From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 3:47 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main I'm glad I have that right. All we need now is the existing conditions plans for the boathouse which is located on a separate abutting lot and connected to the septic system. Once we have that we can make the final determination. Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable 5/5/2008 Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 Joann.buntich@town.barnstab le.ma.us -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Monday, April 28, 2008 1:39 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main I believe that you are correct. We (Sullivan Engineering)specifically requested that the owner have existing floor plans prepared, so that we could use them to determine the design flow, and submit them (as required by the Board of Health)with the septic permit. Sometimes on simple/small houses we will do the existing floor plans ourselves, or have the owner do them, but this house was a little overwhelming. The plans were prepared by an architect. John O'Dea From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 12:14 PM To:john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. Let me see if I understand this correctly- • The"existing"floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. • That is why"proposed"floor plans were not submitted -because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:john sullivanen in.com Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David 5/5/2008 Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of"Bedroom". There for there are three "Bedrooms" in the basement (family room + 2 adjacent rooms), three bedrooms on the first floor(bedroom + office + sunroom) (we made an executive decision to exclude the mudroom), and 7 on the second floor(6 bedrooms+ sitting room). The boathouse is one open finished room. believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. -----Original Message----- From: CJ Riley [mailto:cjriley a�cjriley.com] Sent: Wednesday, April 23, 2008 7:33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application?Thank you, C j Sent via BlackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>,"Sara Alger" <sfa@nantucket.net> Cc:"Weil, Ruth" <Ruth.Weil@town.barn stable.ma.us>,"Daley, Patty" <Patricia.Daley@town.barn stable.ma.us>,"Stanton, David" <David.Stanton @town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator 5/5/2008 i Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley mailto:c'rile ,riley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step?And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via BlackBerry by AT&T 5/5/2008 A Stanton, David From: CJ Riley[cjriley@cjriley.com] Sent: Thursday, May 01, 2008 3:45 PM To: Buntich, JoAnne Cc: Stanton, David; Daley, Patty; Perry, Tom; John O'Dea; Sara Alger; Weil, Ruth Subject: Re: 195 Long Beach 749 and 767 South Main Hi jcanne, Thanks for the comfirmation on all of the documentation of all work proposed. Best, C j riley Sent via B1ackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Thu, 1 May 2008 10:37:28 To:<cjriley@cjriley.com> Cc: "Stanton, David" <David.Stanton@town.barnstable.ma.us>, "Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>, "Perry, Tom" <Tom.Perry@town.barnstable.ma.us>, <john@sullivanengin.com>, "Sara Alger" <sfa@nantucket.net>, "Weil, Ruth" <Ruth.Weil@town.barnstable.ma.us> Subject: 195 Long Beach 749 and 767 South Main Hello Mr. Riley, 195 Long Beach - We have all reviewed the final plans stamped by the architect and have determined that the additions proposed are exactly 25% more than what was in place for that structure on July 1, 1989. 749 and 767 South Main - We have reviewed the floor plans and application and understand that the only work proposed is an upgrade to the septic system. This system is designed to accommodate flows from the existing multi bedroom residence at 749 South Main and the 1 bedroom boathouse at 767 South Main. We understand that no bedrooms are being added to either structure and no structural additions or renovations for either structure are proposed at this time.Please let me know if you have any further questions or need more information. Please let me know if you have any further questions or need more information. Jo Anne Miller Buntich Assistant Director Growth Management Department Town of Barnstable 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us <mailto:joann.buntich@town.barnstable.ma.us> -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Wednesday, April 30, 2008 6:33 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main Jo Anne 1 Per your request please find attached a floor plan of the existing boathouse,. as well as photos - 1 from outside, 1 inside towards bathroom/entrance, 1 inside towards kitchen area, 1 from loft area, and 1 underneath. I hope this helps with your determination. John O'Dea ---------------- From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 3 :47 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main I'm glad I have that right. All we need now is the existing conditions plans for the boathouse which is located on a separate abutting lot and connected to the septic system. Once we have that we can make the final determination. Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us <mailto:joann.buntich@town.barnstable.ma.us> -----Original message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Monday, April 28, 2008 1:39 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main I believe that you are correct. We (Sullivan Engineering) specifically requested that the owner have existing floor plans prepared, so that we could use them to determine the design flow, and submit them (as required by the Board of Health) with the septic permit. Sometimes on simple / small houses we will do the existing floor plans ourselves, or have the owner do them, but this house was a little overwhelming. The plans were prepared by an architect. John O'Dea ---------------- From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 12 :14 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. 2 Let me see if I understand this correctly - * The "existing" floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. * That is why "proposed" floor plans were not submitted - because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [ <mailto:john@sullivanengin.com> mailto:john@sullivanengin.com] Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of "Bedroom" . There for there are three "Bedrooms" in the basement (family room + 2 adjacent rooms) , three bedrooms on the first floor (bedroom + office + sunroom) (we made an executive decision to exclude the mudroom) , and 7 on the second floor (6 bedrooms + sitting room) . The boathouse is one open finished room. I believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. 3 r -----Original Message----- From: CJ Riley [ <mailto:cjriley@cjriley.com> mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 7:33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application? Thank you, C j Sent via B1ackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>, "Sara Alger" <sfa@nantucket.net> Cc: "Weil, Ruth" <Ruth.Weil@town.barnstable.ma.us>, "Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>, "Stanton, David" <David.Stanton@town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I 'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [ <mailto:cjriley@cjriley.com> mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step? And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via B1ackBerry by AT&T 4 a Stanton, David From: John O'Dea [John@sullivanengin.com] Sent: Thursday, May 01, 2008 2:38 PM To: cjriley@cjriley.com; Stanton, David Subject: RE: 195 Long Beach 749 and 767 South Main Does all this mean we can get a permit now??? -----Original message----- From: CJ Riley [mailto:cjriley@cjriley.com] Sent: Thursday, May 01, 2008 3 :45 PM To: JoAnne Buntich Cc: Stanton, David; Daley, Patty; Perry, Tom; John O'Dea; Sara Alger; Weil, Ruth Subject: Re: 195 Long Beach 749 and 767 South Main Hi joanne, Thanks for the comfirmation on all of the documentation of all work proposed. Best, C j riley Sent via B1ackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Thu, 1 May 2008 10:37:28 To:<cjriley@cjriley.com> Cc: "Stanton, David" <David.Stanton@town.barnstable.ma.us>, "Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>, "Perry, Tom" <Tom.Perry@town.barnstable.ma.us>, <john@sullivanengin.com>, "Sara Alger" <sfa@nantucket.net>, "Weil, Ruth" <Ruth.Weil@town.barnstable.ma.us> Subject: 195 Long Beach 749 and 767 South Main Hello Mr. Riley, 195 Long Beach - We have all reviewed the final plans stamped by the architect and have determined that the additions proposed are exactly 25% more than what was in place for that structure on July 1, 1989. 749 and 767 South Main - We have reviewed the floor plans and application and understand that the only work proposed is an upgrade to the septic system. This system is designed to accommodate flows from the existing multi bedroom residence at 749 South Main and the 1 bedroom boathouse at 767 South Main. We understand that no bedrooms are being added to either structure and no structural additions or renovations for either structure are proposed at this time.Please let me know if you have any further questions or need more information. Please let me know if you have any further questions or need more information. Jo Anne Miller Buntich Assistant Director Growth Management Department Town of Barnstable 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us <mailto:joann.buntich@town.barnstable.ma.us> -----Original Message----- 1 I From: John O'Dea [mailto:john@sullivanengin.com] Sent: Wednesday, April 30, 2008 6:33 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main Jo Anne Per your request please find attached a floor plan of the existing boathouse, as well as photos - 1 from outside, 1 inside towards bathroom/entrance, 1 inside towards kitchen area, 1 from loft area, and 1 underneath. I hope this helps with your determination. John O'Dea ---------------- From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 3 :47 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main I'm glad I have that right. All we need now is the existing conditions plans for the boathouse which is located on a separate abutting lot and connected to the septic system. Once we have that we can make the final determination. Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us <mailto:joann.buntich@town.barnstable.ma.us> -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Monday, April 28, 2008 1:39 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main I believe that you are correct. j We (Sullivan Engineering) specifically requested that the owner have existing floor plans prepared, so that we could use them to determine the design flow, and submit them (as required by the Board of Health) with the septic permit. Sometimes on simple / small houses we will do the existing floor plans ourselves, or have the owner do them, but this house was a little overwhelming. The plans were prepared by an architect. John O'Dea 2 i s - ---------------- From: Buntich, JoAnne (mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 12 :14 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. Let me see if I understand this correctly - * The "existing" floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. * That is why "proposed" floor plans were not submitted - because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [ <mailto:john@sullivanengin.com> mailto:john@sullivanengin.com] Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of "Bedroom" . There for there are three "Bedrooms" in the basement (family room + 2 adjacent rooms) , three bedrooms on the first floor (bedroom + office + sunroom) (we made an executive decision to exclude the mudroom) , and 7 on the second floor (6 bedrooms + sitting room) . The boathouse is one open finished room. I believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer' will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. 3 a Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. -----Original Message----- From: CJ Riley [ <mailto:cjriley@cjriley.com> mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 7 :33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application? Thank you, C j Sent via B1ackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>, "Sara Alger" <sfa@nantucket.net> Cc: "Weil, Ruth" <Ruth.Weil@town.barnstable.ma.us>, "Daley, Patty" <Patrici@.Daley@town.barnstable.ma.us>, "Stanton, David" <David.Stanton@town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I 'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original message----- From: CJ Riley [ <mailto:cjriley@cjriley.com> mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, 4 I Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step? And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via B1ackBerry by AT&T 5 I '8tanton, David From: Buntich, JoAnne Sent: Monday, April 28, 2008 3:47 PM To: 'john@sullivanengin.com; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty; Perry, Tom Subject: RE: 749 south main I'm glad I have that right. All we need now is the existing conditions plans for the boathouse which is located on a separate abutting lot and connected to the septic system. Once we have that we can make the final determination. Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 Joann.buntich&town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Monday, April 28, 2008 1:39 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main I believe that you are correct. We (Sullivan Engineering)specifically requested that the owner have existing floor plans prepared, so that we could use them to determine the design flow, and submit them (as required by the Board of Health)with the septic permit. Sometimes on simple/small houses we will do the existing floor plans ourselves, or have the owner do them, but this house was a little overwhelming. The plans were prepared by an architect. John O'Dea From: Buntich, JoAnne [ma ilto:Joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 12:14 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. Let me see if I understand this correctly- . The"existing"floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. . That is why"proposed"floor plans were not submitted - because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne 5/5/2008 .r Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 Joan n.buntich@town.barn stable.ma.us -----Original Message----- From: John O'Dea [mailto:iohn sullivanengin.com Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of"Bedroom". There for there are three"Bedrooms" in the basement(family room + 2 adjacent rooms), three bedrooms on the first floor(bedroom + office + sunroom) (we made an executive decision to exclude the mudroom), and 7 on the second floor(6 bedrooms + sitting room). The boathouse is one open finished room. I believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. -----Original Message----- From: CJ Riley [mailto:cjriley@c'r@ iley.com] Sent: Wednesday, April 23, 2008 7:33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application?Thank you, C j Sent via BlackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 5/5/2008 To:<cjriley@cjriley.com>,"Sara Alger" <sfa@nantucket.net> Cc:"Weil, Ruth" <Ruth.Weil@town.barn stable.ma.us>,"Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>,"Stanton, David" <David.Stanton @town.barnstab le.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [mailto:cjriley cfrile .com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review.At this point what is the next step?And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via BlackBerry by AT&T 5/5/2008 I ti. Stanton, David From: John O'Dea [John@sullivanengin.com] Sent: Monday, April 28, 2008 1:39 PM To: Buntich, JoAnne; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main I believe that you are correct. We (Sullivan Engineering) specifically requested that the owner have existing floor plans prepared, so that we could use them to determine the design flow, and submit them (as required by the Board of Health)with the septic permit. Sometimes on simple/small houses we will do the existing floor plans ourselves, or have the owner do them, but this house was a little overwhelming. The plans were prepared by an architect. John O'Dea From: Buntich, JoAnne [mailto:joann.buntich@town.barnstable.ma.us] Sent: Monday, April 28, 2008 12:14 PM To: john@sullivanengin.com; cjriley@cjriley.com; Sara Alger Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. Let me see if I understand this correctly - . The"existing"floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. . That is why"proposed"floor plans were not submitted - because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:john&sullivanen in.com Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, 5/5/2008 I y 'The Board of Health has very strictly enforced the Title 5 definition of"Bedroom". There for there are three"Bedrooms" in the basement(family room +2 adjacent rooms), three bedrooms on the first floor (bedroom + office + sunroom) (we made an executive decision to exclude the mudroom), and 7 on the second floor(6 bedrooms + sitting room). The boathouse is one open finished room. believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. -----Original Message----- From: CJ Riley [mailto:cjriley(a-_)cjriley.com] Sent: Wednesday, April 23, 2008 7:33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application?Thank you, C j Sent via BlackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>,"Sara Alger" <sfa@nantucket.net> Cc:"Weil, Ruth" <Ruth.Weil@town.barn stable.ma.us>,"Daley, Patty" <Patricia.Daley@town.barnstab le.ma.us>,"Stanton, David" <David.Stanton @town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 5/5/2008 Ijoann.bun4ch@town.barn stable.ma.us -----Original Message----- From: CJ Riley [mailto:cjriley@clriley.coml Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step?And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via BlackBerry by AT&T i 5/5/2008 i t . Stanton, David From: Buntich, JoAnne Sent: Monday, April 28, 2008 12:14 PM To: 'john@sullivanengin.com'; cjriley@cjriley.com; 'Sara Alger' Cc: Stanton, David; Daley, Patty Subject: RE: 749 south main Thanks very much Mr. O'Dea, sorry for the delay I was out of the office. Let me see if I understand this correctly- . The"existing"floor plans submitted with the application are an exact representation of the number of bedrooms and use of the structures proposed after the upgrade to the disposal works. . That is why"proposed"floor plans were not submitted - because there are no changes to the number of bedrooms or use of the structures. Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: John O'Dea [mailto:john@sullivanengin.com] Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of"Bedroom". There for there are three "Bedrooms" in the basement(family room +2 adjacent rooms), three bedrooms on the first floor (bedroom + office + sunroom) (we made an executive decision to exclude the mudroom), and 7 on the second floor(6 bedrooms + sitting room). The boathouse is one open finished room. I believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the.country for three weeks on Saturday, so if any plan revisions are required, the work 5/5/2008 would be cdnsiderably delayed. John O'Dea Sullivan Engineering. -----Original Message----- From: CJ Riley [mailto:cirile ciri�.com] Sent: Wednesday, April 23, 2008 7:33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application?Thank you, C j Sent via BlackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>,"Sara Alger" <sfa@nantucket.net> Cc:"Weil, Ruth" <Ruth.Weil@town.barnstab le.ma.us>,"Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>,"Stanton, David" <David.Stanton@town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [mailto:cjriley@c rJ iley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step?And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via BlackBerry by AT&T 5/5/2008 Stanton, David From: John O'Dea [John@sullivanengin.com] Sent: Thursday, April 24, 2008 9:15 AM To: cjriley@cjriley.com; Buntich, JoAnne; 'Sara Alger' Cc: Stanton, David Subject: RE: 749 south main Jo Anne, The Board of Health has very strictly enforced the Title 5 definition of "Bedroom" . There for there are three "Bedrooms" in the basement (family room + 2 adjacent rooms) , three bedrooms on the first floor (bedroom + office + sunroom) (we made an executive decision to exclude the mudroom) , and 7 on the second floor (6 bedrooms + sitting room) . The boathouse is one open finished room. I believe the Board of Health agents would confirm the design flows. Although there are no signs of failure at the boathouse, as there were no signs at the main house, the owner has been adamant about upgrading, as she has spent many years on the River, and does not want to be responsible for any further degradation. Because of the amount of work required to upgrade the system for the main house, it us unlikely that an installer will have time to fully investigate, and upgrade the boathouse system if required this spring, so we have put off further evaluation until the fall, but included it in the design - if needed. Please let me know as soon as possible if you need any additional information. The clients are very anxious to get the system in. Also, Peter Sullivan will be leaving the country for three weeks on Saturday, so if any plan revisions are required, the work would be considerably delayed. John O'Dea Sullivan Engineering. -----Original message----- From: CJ Riley [mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 7 :33 PM To: JoAnne Buntich; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application? Thank you, C j Sent via BlackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>, "Sara Alger" <sfa@nantucket.net> Cc: "Weil, Ruth" <Ruth.Weil@town.barnstable.ma.us>, "Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>, "Stanton, David" <David.Stanton@town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. 1 i Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step? And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via B1ackBerry by AT&T 2 Stanton, David From: CJ Riley[cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 7:33 PM To: Buntich, JoAnne; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David; John O'Dea Subject: Re: 749 south main Joanne, There is no increase in bedrooms we have documentation complete by catalono architect by full as built plans, do you have those in with the application? Thank you, C j Sent via B1ackBerry by AT&T -----Original Message----- From: "Buntich, JoAnne" <joann.buntich@town.barnstable.ma.us> Date: Wed, 23 Apr 2008 16:27:44 To:<cjriley@cjriley.com>, "Sara Alger" <sfa@nantucket.net> Cc: "Weil, Ruth" <Ruth.Weil@town.barnstable.ma.us>, "Daley, Patty" <Patricia.Daley@town.barnstable.ma.us>, "Stanton, David" <David.Stanton@town.barnstable.ma.us> Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step? And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via B1ackBerry by AT&T 1 Stanton, David From: Buntich, JoAnne Sent: Wednesday, April 23, 2008 4:28 PM To: 'cjriley@cjriley.com'; Sara Alger Cc: Weil, Ruth; Daley, Patty; Stanton, David Subject: RE: 749 south main CJ, It is unclear from the filing whether or not there is an increase in bedrooms proposed. Once we have documentation that shows that no additional bedrooms are proposed the septic work can proceed. The application materials on file show a bedroom in the boathouse and 13+ bedrooms for the main house. The exiting conditions floor plans submitted show a lesser number of bedrooms in the main house and no bedroom in the boathouse, which is located on a separate abutting lot. I'm sure this will be resolved as soon as we have this documentation from your engineer Thanks, Jo Anne Jo Anne Miller Buntich Special Projects Coordinator Town of Barnstable Growth Management Department 367 Main Street Hyannis, MA 02601 p 508 862 4735 f 508 862 4782 joann.buntich@town.barnstable.ma.us -----Original Message----- From: CJ Riley [mailto:cjriley@cjriley.com] Sent: Wednesday, April 23, 2008 6:03 PM To: Buntich, JoAnne; Sara Alger Subject: 749 south main Dear joanne, Sullivan engineering brought a septic plan into board of health to replace a system @ 749 south main and I understand that it is @ growth management for review. At this point what is the next step? And I can tell you that what promted this new system is that there is no record of anything for an existing septic on this property, and @ this point what is there is not good for the river. Thank you, C j riley Sent via B1ackBerry by AT&T I 1 C.J. Riley Builder, Inc. 1OB Wianno Avenue Osterville; MA 02655 cc*• 114 1 O. "s x P: (508) 428-6376 F: (508) 428.6076 www.cjriley.com cj@cjriley.com O] DIRECTIONS: st31�f .t� kr \ / N •� � nolrx a�:sa,e°d°r°��w mii°IP°.�iw°.mat mm �`�'°'N' i �f�e � 'a``` id p. tdn o xyrt wto SMM 5aoel.hM lum!hto 7v _'S'7 �1�� .i maioowlswaua°t1Rse��la�a°nw�n�d�tte:iiiRp{a1('y;`• CMD E) \Ix !p.[ .•-�T. Locus * � �..� .. u �^ ,:R.1'T1.'l:t'II.LR°�•,IfARROf , Locus Yap ain- 1\ ,'r,'..:%..-.. 1 Y 1 Ip•�! 191■t4t°'•RM'•aY°� :.- t 1 Soutf� F.: ASSESSORSRE OVERLAY DISTRICT: 1 r T Q AP-Awra.n°a°a..naekl � 1 � // � canmamty Pwr fro. BEO{• /^ / •• .•,__ A, "/ 1 • � I n /tJ 3 000R 1 OOtIBY60 'F-, ��_.•tY...... _ -q w``_...� ,..._ ... .-. ul T .. r« 1, `•'.II`.�'�', r� ��. 0 I mr,tm.L.i'ra,v... ZONE. Ro-t '1'{ 1 r clR,u 1 +a z lnt FANOOnt(mh.)F)t 3°(RPoo) 1 ,. '$..y" - -'- � In mhf()173' R—sift Ito ' 11 a r ,' e. / �• OWNER: M•.K'.wf t r', •• •¢•' I i i F i '�'.• Rarw°r E wd V-tta o— \..- �, i I- 1 10"`fL ' ••-� / /// / % /-••-.•fl r _ "�`` 740S fh woh strwt CmI.W1.MA �Y REFERENCES: s Lc ww eeea}1 1 1 °-•• o..lx i—•' A ' f"'_� _ - --- Pkn e3i'Oi Poa:SP �'� �:r� � 6,, � !„• .. -'� _ � � .r —— - — D.W Book ` l i 1 +� •i Legend., Ib,ten uw li ,, + /r,!• _.�., _.'::-�, - It , --_- �• �� — •'- -• ._-. 1! 0 5a6s rut P O uae■exer /a!a°or dma oats p maA emn Hx Jdr t.taet _. ^ „ ;+ ''•r••` • .•_ 0 xayytr GO • [rM 'r/ V9Tt,Pd. m O/w aW mmwww.amna /"Attfatt) - i't t% - Owa(m.rq • u/➢'f Ao»bend./Gmrd. - / �'.•"! ■ Ims w..futn.ey mind .I t� � '�" Deataaw!rme • wmvas.� m. - --w•—w.n.ae c« aanay.r River �. a Centerville NOTES PREPARm F02 PRCPM)D er. RITE Site Plan L)m. rtr rh.kramatrw aherm r.a. Ramsay E and Merrilee Craln Sullivan Engineering,Inc. CapeSury Proposed Garage .— c Id ftm.w6aDfe 7.ard hr.tauw 749 South Main Street Poe ess )ea,.l.Rasa at 0lterullnaMA 0T633 Ostevn MA 02655 T.),he tesopvphk hfamaffw w.anfahW Centerv®le. MA 749 South Main Street kpn w w m. fro /W w- (xn..ro-Jw pa.Nm-art!to neL° 10 rnrmee"'lam� oP-Defelrr 7/JA"a°I^clfo■". Barnstable(Centerville)Mass. 1)Th.defan aW a NOW'TA a r.W mew Dral1: J00 nd1 RRL(D" lerol data.(. S0 >0 W PS. e: Can.: RRLD■9 OATEI RNv SCAT£ 1"e20� October23,NO Ro al T6039 Pro 1/ C217 No. THE COMMONWEALTH OF MASSACHUSETTS En[eredincomputer: Yes PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS • Ztpprication for 30igp0al *p5tem Congtruction Permit Application for a Permit to Construct O Repair O Upgrade(.<Abandon O Complete System❑Individual Components Location Addressor Lot No. '7qI bk-_ Owner's Name,Address,anQ Tel.No. �Q�`�" RSS3��t �slewu)h Cwe_e _C+"a•�n Assessor's Ma/Parcel 6 P IBS O Z v01 Iw,r�ae!'r.Kc� s Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No. �b ut Type of Building: ` Dwelling No.of Bedrooms 13* t Lot Size —�' sq.ft. Garbage Grinder (� Other Type of Building No,of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow(min.required) IS4 0 gpd Design flow provided S1 gpd Plan Date hQr.� Z\� 20G10 Number of sheets Revision Date Title SNC Size of Septic Tank 356t) Type of S.A.S. 1`i'S� b�� C1t�r.�v5 in IZI,�,X IZ5 Description of Soil R�_'-17. 05v7_ 0-15 , 6A 33-4y 3(A4CQ_ ONKSilo LOA-'^1 2,6D L14-51" t (AIK-0, 104k(ejd MOD SP,N►7 S -I'3L" C 4-ICa— ,S`I & Nature of Repairs or Alterations(Answer when applicable) I - j Date last inspected: c Agreement: `- 'The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewag disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation u tiI a CertiMate ot-', • Compliance.has been issued by this Board of Health. o r_ Date Application Approv y Date S Application Disapproved by: Date for the following reasons Permit No. Date Issued G THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE,MASSACHUSETTS Certificate of (Compliance THIS IS TO CERTIFY,that the On-site Sewage Disposal System Constructed ( ) Repaired.( ) Upgraded (/) Abandoned( )by L/ at 41 5-AV, nickut has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. 'D ( dated S /" Installer Designer #bedrooms 3 1 Approved design flow gpd The issuance of this permit shall not be construed as a guarantee that the system will function as designed. Date Inspector ——————————— ---No. � " t --------------------- Fee OCJ 1 THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION-BARNSTABLE,MASSACHUSETTS Migpogal *pgtem Congtruction Permit L Permission is hereby granted to Construct ( ) Repair { ) Upgrade (✓ Abandon ( ) System located at Se,�h 'Y*, Cenlwt and as described in the above Application for Disposal System Construction Permit.The applicant recognizes his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construction ynust be completed within three years of the d e of this per t. Date � 0 Approve Town of Barnstable Regulatory Services Thomas F.Geller,Director Public Health Division Thomas,KcKua,Director 200 Main Street,ByanWs,MA 02601 Office: 508-862-4644 hex: 508-790-6304 Installer.& Designir Certification Form Date: lol zzl 0o Designer: 5_!eI I I V&I'J Installer:' RXK-o-y-s '&ce.&-v An t� Address: o 90-�r &6 g Address: P.a B Q:4 tZ$9 On GxcA-v Pm bo was issued.a permit to install a (date) (installer) septic system at -749 56vl-A IT C i based on a design drawn by (address) dated i Y--V'a� (designer) I certify that the septic systern referenced above was installed substantially according to the design, which may imIude minor approved changes such as lateral relocation of the distribution box and/or septic tank. I certify that the_ septic system referenced above was installed_with major changes (i.e. greater than 1.0' lateral relocation of the SAS or any vertical relocation of any component of the septic system)but in accordance x ith State & Local Regulations. Platt revision or certified as- ilt by designer to follow. =v SULLIVAff s �i nature) Na.29733 (Designer's Signature) (Affix Designer's Stamp Here) PLEASE RETURN TO BARNSTABLE PUBLIC REAL DWISION. CERTIIRCATE OF COMPLIANCE WILL 141OT BE ISSUED UNTIL B( —TH THIS FORMAND 4S BUILT CAM RECEIVED BY THE BARNSTABLE PUBLIC HEALTH DIVISION. THAhT K YOU. i Q:Heaith/ScptioDesigaer Certification Form • • Pj. TIDE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE,MASSACHUSETTS ST Certificate of Comptiance THIS IS TO CERTIFY,that the On-site Sewage Disposal System Constructed ( ) Repaired ( ) Upgraded (i'j Abandoned( )by c_ 6`LQ_U � at 4 - ef 4kVJ has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. rt "� dated Installer Designer • #bedrooms t Approved design flow gpd The issuance of this permit shal not Wcstrued as a guarantee that the system wi�nctiosi ed. Date _VInspector �� o ............ p 125 egft + ............. �.... ................................. GROSS SQUARE FOOTAGE: 3RD FLOOR TOTAL; 1,252 OF GRAND TOTAL: 12,627 5� 25%OF GRANQ TOTAL, 3,132 OF i x � . . .. .......... .............. EXISTING GROSS SQUARE FOOTAGE: 2ND FLOOR MAINS 3,024 OF 2ND FLOOR BOATHOUSE: 173 5F 2ND FLOOR TOTAL: 3,197 5F GRAND TOTAL: 12,527 5F 25%OF GRAND TOTAL: 3,132 OF t7267eq'k ,,, �=t;-eqA ' � 0 iffffFA 173 z4 aq h :s i O - � i EXISTING GROSS SQUARE FOOTAGE: 1ST FLOOR MAIN: 3,460 SF 16T FLOOR FOOLHOUSE; 173 SF J 1ST FLOOR BOATHOUSE: 967 SF V i 15T FLOOR TOTAL: 4,606 SF / 967ABegi4 GRAND TOTAL: 12,527 SF A , ( 2616 OF GRAND TOTAL: 3,132 SF41 LA go 6 0 • y n ' �` ' 347170egft �- GRO55 SQUARE FOOTAGE; � BASEMENT TOTAL- 3,472 5F GRAND TOTAL- 12,627 OF � 25%OF GRAND TOTAL: 3,132 5F .............................................................................. iE ........................................ . ..... Fl I F-� ................................................................. BATHROOMO . ........ .... .................................................................... OFFICE -jp7 .......................... BEDROOM CL BATHROOM aaLAUNDRY ENTRY HALL II PARLOR II NUM ROOM lFP FF. Lrlfm ROMN RA II II II a II .......... ................ ............................................................................ I..................................................... SUNACM ............................. .............. ........ .................................................................. . ^ � � . . ' . � � . � � � CL � sm BATH F BATH CL FCLIL .------------ BEDROOM :01 � BEDROOM SrTTEMG ROOM CL BATH CL CL El � . � � ----- � BEDROOM � .-----------`------------'/ `-----------------.. BATH BAN ZD .' ( � . / �. -----------------------------------------------'� � ^ � / , � i I, STORAGE I STORAGE STORAGE 1 LL 0 L)= L- MECHANICAL STORAGE F'R BATHROOM STORAGE T FAMILY ROOM TORAGE 1 Existing Basement L/ SGALE:1/4"=P-0" 1 c • 1 STORAGE Li STORAGE STORAGE CL • - MECHANICAL STORAGE r F.P. BATHROOM STORAGE FAMILY ROOM I iORAGE Existing Basement V SCALE:1/4°= i L ................................... ... ........................................... ........................................ BATHROOM .................................................................... ........... .................... .................. 0 CE HE OFFI KITCN r FP- L ......................... aBATHROOM .................... ....................................... ==4 LLr v Na a ENTRY HALL < PARLOR 'F.P FIR No ROOM I LIVING ROOM ri II II II KITCHEN II II i II ........... ............. LCL� II ............................................................................. .................................. ............................ ................................................................................................................................................................................... • ............................................................................... .......................................................... ........... ........................................... CL Billu . ....................... ..... ............... %.................................................................. STO. BATH BEDROOM .......................... CL BATHa........................................................... a. 10 P--4 FF BEDROOM a. BEDROOM S"TM ROOM CL � a .001i J BAN CL ......................... BBDRmM BEDROOM BEDROOM .... ............. ........ CL C CL � L .... ........................ ...................... .............................................................................. 10 MTN BATH COC -m N==Md mmm= rs ....... ...... t....................................................................... ........................................................................................................... : EXISTING OCCUPIABLE 5F: BA5EMENT70TAL 7545F. _. 15T FLOOR OCCUPIABLE 5F: 15T FLOOR MAIN: 3,076 5F. 15T FLOOR POOLHOU5E: 141 5F 15T FLOOR BOATHOUSE: 887 SF 15T FLOOR TOTAL: 4,104 5F ..: �.. 2ND FLOOR OCCUPIABLE 5F-.: 2ND FLOOR MAIN: 2,543 SF 2ND FLOOR BOATHOUSE: 173 5F: 2ND FLOOR TOTAL: 2,716 5� .GRAND TOTAL: 7.574 5F 25%OF GRAND TOTAL: ::.1.594.5F. - PROPOSED OCCUPIABLE 5F: 1,261 SF. OGGU table 13a5emeYlt i� _ _ q. A' - --_ _ - o 2 0ccu fable lot Floor .71 ... .. .. - ape. .. / t t O I ..... _ Crain - Residence 749 South Main Street ---- Im ermeable Site Centerville MA 4 PRE-1959 IMPERMEABLE SQUARE FOOTAGE: 25%AVAILABLE FOR ALL ADDITIONS:: 3,156 5F SCALE. .... :. DATE:::.: .... `N MAIN FOOTPRINT: 3;466 5F P05T-1959 IMPERMEABLE ADDITION5: BOATHOUSE FOOTPRINT: 967:SF LAND SCAPE PAVING: 1,512 5� POOL,ETC. 974 5F C -380 SF Catalano Architects Inc. ENTRY PORTICO•. 75 SF PROPOSED DECK COVERING PAVED DRIVEWAY: 6,602 5F 115BroadStreet IMPERMEABLE SF AVAILABLE FOR GARAGE:.1,502 5F Boston.Wssachesenso2110 TOTAL: 12,622 SF PROPOSED GARAGE IMPERMEABLE SF: 1,797 SF elephone 617-33 facsimile 677-338-6639-6639 3 Occu fable 2nd Floor 3 1:O ih 4 1 Basement Gross 5 uare Feet EXISTING BASEMENT GPO55 5F: BASEMENT MAIN- 3,472 5F POOLHOUSE BASEMENT- 967 SF BASEMENT TOTAL- 4,439 SF Wz.g EXISTING 15T FLOOR GRO55 SF: 15T FLOOR MAIN: 3,466 5F u_ Q a,�,y� 1ST FLOOR POOLHOUSE: 173 SF 15T FLOOR BOATHOUSE: 967 5F ! 15T FLOOR TOTAL: 4,606 5F EXISTING 2ND FLOOR GRO55 5F: ti:os,y2 _.._............ 2ND FLOOR MAIN: 3,024 5F 2ND FLOOR BOATHOUSE: 173 SF -- 2ND FLOOR TOTAL: 3,197 5F Lj EXISTING 3RD FLOOR GRO55 5F: _ 2 15t Floor Gross 5cluare Feet 3RD FLOOR TOTAL: 1,252 SF EXISTING TOTAL: 13.494 5F 25%OF GRAND TOTAL: 3,374 5F PROPOSED 15T FLR GRO55 5F: 1,649 SF i wh PROPOSED 2ND FLR GRO55 SF: 1.377.5F PROPOSED TOTAL: 3,026 5F e r\ 9.Ogy,gB - i vq� ®Catalano ArNitMsIM. ' 1 3 2nd Floor Gross 5 uare Feet Crain Residence 749 South Main Street Centerville,MA SCALE: ........_....' r . . :.......... DATE: r _ _ 0..,. .............. r Catalano Architects Inc. 116 Broad Street sP Boston,Massachusetts 02110 i tele0hone 617-338-7447 r facsimile 617-338-6639 I 4 3r6l Floor Gross Scluare Feet r ,doe�e ---------- ------------- ------ -------------- -------- ------- ------ ------------- ----------- --------------------- -------------- --------------------------------------- ---------- ------------ �- -.--* � ----- ------------------ ------ -------------::__:::------------------- ------------------------------- ---------:--------------------------- -: -:-::---------------------------------- -------------------- -------------:--------------------------------- -------- --------------------- -------------------------:------- --------- -------- -------- ------------ --------- -------- - ----- - - ------------------ --- ------------- : -------------- ------------------------------------------------------------- -------------- --K------ ------- --------- - ----------------- -- --------- --- ---------------- ---- --------- - ----- -----------:--- --- --------- -----------::- - ----------- ------------ - -- --------- - -------- --- --- ------ ------ ----------- - ----- ---- --------- -------- - ------- U - - ------- ------ --- ------- -------- -- - -::::::: --------- --- ------- --- ------ ---- --- ------- ----- ------- ----------- ------ 7 7: ---------:77 ---------- --- --- -- --------- -------- ---- ------ -- ---------- ------- ------ ------ ----- ------ ---- ------ ------ ------- ------ ------------ ------------- ------ ------- -- ------------- -------------- -------- ----------- -7: ------ -------- --------------- ----- --- - ----------- -------------------------------------------- -------- ------- ------------- ------------- ----- ---- -- -:-:- ----------------- ----------------::------- -----------------------::-------------- ----- --- :------------- --------------- --------- ----- --------- ------ -------------------------------------- A--------------------- ----------------------------- -- --------- -- ---------:. - -------------------------------- --------------- -- ------------- ------------------ ------ - -- ------------------------------------------- - ----------------- ----------------- EEO n ---------- 000 H DI I 11M AR 11 1 A AIR Z CRAIN GARAGE November 10, 2008 Index of Drawings ®Catalano AnJft—In,, SFA Square Feet Calculations A2 1 Exterior Elevations(West) SF2 Square Feet Calculations A2:2 Exterior Elevations(East) Crain A2.3 Exterior Elevations(South) Residence At 1 First Floor Plan A3.1 Building Section(at Parking Bays) At:2 Second Floor Plan A32 Building Section(at Center) 749 South Main Street A1.3 Roof Plan Centerville,MA S1.0 Foundation Plan SCALE: DATE: Catalano Architects Inc. • 5 Broad Steel Boston,110assachusetts 02110 telephone 617-338-7447 facsimile 617-338-6639 �1 O i F� TO.SHELF % ELEV=9'-6" 4 ` TO.FOOTING ELEY=6'-G" - T.O.COLUMN BASE ELEV=14'-2° TO.FOOTING j / ELEV=6'IN / / / / T.O.FOOTING ELEV=5'-O" - / T. WALL TO.5LA80'-111/2"LOW POINT) / / / ELEV=14'-2" ELEV=1 TO.SHELF TO.WALL / / / / ELEV=B'6" FELEV=id-B 1/2" / / T.O.SLAB(HIGH POINT1(Y-81/ B5HELF\ ELEV=11'-d' T.O.FOOTING - \ T.O.F � ELEV=14'-2" / / z:.rw ATPHAI- OOTING — ELEV=6'6" � / - ELEV=6-6. / i Lr�:a Ton 1 --1 5- 11 ALD - ,5 / T0.LE5HE 'n EV=9'6" T.O.5LAB I ____ _ _ __ , :'F CO/yTRp/✓p/N // (LOW POINT ELEV=1T-6" 1 I T.O.SHELF T.O.SHELF \ ram` / TO.FOOTING I ELEV=11'-d' ELEV=11'-d' F S ELEV=5'-O" I T.O.WALL TO.WALL \_j I ELEV=14-2" ELEV=14'-2" T.O.WALL ELEV=14'-2" TO.HELP �':6°COR,Istsbo6 GiodewtzELE i I -6 6W21 a N21 WWF', I I I •_' o'Farrs;riaL,l,ar'.:, � r<----� / / r Orar 6TMLL 1 Oran a.. p,uted GraI Be a. ®calal—�nan:lz. I HOLE IN SLAB FOR 6-0"X G-O"LIFT \ / % % Crain I � I Residence � � / X 749 South Main Street TO.sLAs i --- Centerville,MA HIGH POINT) I r___________________________ ELEV=IV-9° _J r____________________________L---- --------------------------h ___-� \\ FOUNDATION PLAN ---- ------ ------' ———— J 9 FOU c 4"LL 5i T 11Rii,F \ SCALEA/4° T-0• ..u#r.:u.v.sTDUE=UP,FJ�YiC \ BATE:Monday,November 10,2008 Catalano Architects Inc. 115 Broad Street Boston.Massachusetts 02110 telephone 617-338-7447 facsimile 617.338-6639 S 1.0 SEPTIC NOTES OVERLAY DISTRICT: �. 1.Location of Utilities Shown on This Plan Am Approx.At Least 72 Hours AP - Aquifer Protection District « � w • �• Q s �. + / o`ac B\ti Prior to Any Excavation For This Project the Contractor Shall Make t the Required Notification to Dig Safe(1-888-344-7233). / 2.The Contractor is Required to Secure Appropriate Permits From Town \ , e(otlj / Agencies For Construction Defined by This Plan. FLOOD ZONE. • „ A10(EL11) / ty Pj vt 3.The Water Line Shall be Constructed in Coordination With Y l} _� ovn oyo � Zone A 13(EL 11), B, & C ��, �� MA Zone C /t L COMM Water,and Shall be in Accordance With 248 CMR 1.00-7.00 .. FE �.• 19 j Covn y &310 CMR15.00. Community Panel No. �,; B / �g19 .' o 1 ,�•• '"`' 4.Install Risers with Cover to Within 6"of Finished Grade(7 Required). #250001 0016D »�'» Cover Over Pump Shall be Cast Iron. July 2 1992 f rat) a �- w� 5.All Structures Buried Three Feet or More or Subject r-� � :�.°• ` � �� �-- to Vehicular Traffic to be H-20 Loading.It is the Engineer's41 6 k r r t. • a Recommendation that H-20 Always be Used. .' ~ R89 e O oNw ZONE. RD-1 6.Septic System to be Installed in Accordance With 310 CMR 15.00& : qi}. •tl�b ''�� •! �t ' 248 CMR 1.00-7.00 Latest Revision and the Town of Barnstable = r trai I m Area (min.) 87,120 SF (RPOD) - rrfr 10 oMN Board of Health Regulations. Frontage (min) 20' at tlM M � \ .: 7.All Piping to be Sch.40 PVC. Width (min) 125' -• w 8.Inlet Tees Shall Extend a Minimum of 10 '40" Setbacks: ) i E Below the Flow Line. t Yr , 9.An Outlet Tee Shall Extend 14"Below the Flow Line, Front 30 �` x Side 10' g and Shall be E ui ed With a Gas Baffle. r n - Granite Curb \ // q P •.. 10.Existing Septic Systems Shall be Located and Removed Rear 10 ,,,. . • ••• �,. A oNw ,,- vvv �, LCB or Pumped and Filled in Accordance with 310 CMR 15.354. « �`�-_ �" `��•�-� ° ���t• , - ''�' Bit Walk �. . - � curb ran! `` / ....... R.17.4 , ' ,W ,.....,,E:.• r Locus Map .-- -- :32 40 1 r �Iw '"''' Ngp 1 Scale: 1"=2,000±' �Gu i \ 1°� �36.63 ,: ............ E a LCXout) 0 °r+w ROPO ;ED a /i ` 1\ _ 1g19tate Highw y w ° t P VENT I! .: �/: ASSESSORS REF.. c (,10' Wide w ` - - 2 ....... • ••. ....,• ., Map 185 1 p �" " // ,'� Parcels 012 001 and 012 00 o OH . ..... Of pavement 1 #.. ......... J ot+w 7.52 / ®Ei=12.30NGVD „'' DESIGN DATA t Edge -.- JJ / (top of Pvc) U w E / %........ ... ..DH� (� AA// // Single Family-13 Bedrooms R-2oo� + 8 0' } 11- 28h / t /' rr yy 2 a/r r' Finish Grad \ \ N g 0 5 f- ly // ..,,a �/ n +1 Bedroom Capacity Provided For 64N11 r pc \//✓'� Future Upgrade of Boathouser"- .-t / \( ...✓ N �9// 14 Bedrooms Total .min. :„E! „ ( // R=10.0 ---, \mow ,,••""/ g•80 \ \�--,: , r' /...... /; 1 N + p� LEACHING O ` No Garbage Grinder 9"Mm Compacted Fill Filter � CATCH p ':�:\'066 i,\��. ••' _ = TH-2 , 123 - - O Q - 1 ,/ BASIN �1\ Daily Flow=14 X 110 GPD=1,540 GPD Fabric A•S• // ` 0`1 PRO Septic Tank: 1,540 GPD x 200%=3,080 Gallons i e D/o2 - - sG �\\�a /� \��'• l POSED / /i� 2" Use Gallon Septic Tank j ✓ ✓ f..r ........ �(F,y�� ached � 3500 S ti Pea Stone 4 , / �. ,• �� / / ' / I 3' Double W / 0 ,, LEACHING AREA 21 LEACHING Stone r ✓ 1 �Q\'/ �c\\ % Lawn ,j CHAMBER / /� 1,540 GPD/0.74=2,081 SF Required 14 \ �- /i' / /, �' '�.� Sidewall=2 12-10' +123 2 =543 SF P O O PROPOSED /ir �,� �� 0 l Bottom Area=(12'-10"x 123')=1,578 SF 4'-10" -� o ` ` 1 Lawn :. EXISTING OSEp SEPTIC ,, ,/ �C Lawn FEMA Zone Lines 2,121 SF Total Provided J I f �\ 1`: /i ' WATER _ PROP MP TANK �' �,/r /i ( r`\ as shown on FIRM Panel 12'_10» � e• SERVICE` ii , / � # 250001 0016 D I - " TO 13EIC CHAMBER J rev. July Z 1992 LEACHING CHAMBER DESIGN Cross Section Of Chamber All Pipes to be Schedule 40. Use M I rrrrrrr��Ir��r rrrr I " ° ,%' j f e Not to Scale rrrrrrrr��rrrrrr rrrr ; / -% % ,\ 14-500 Gal.Leaching Chambers in a FEMA Zone 1 ( � E � rrrrrrrrrr rrrrr rrrrrrrrr `\`- _ - -' -,,-- //ice� 12'-10"X 123'Washed Stone Fields a Shown. rrrrrrrr rrrrrrrrrrrrr rrrrrrr / o 2_ - OP�bSED _ ti A13(EL11) I rrrrrrrrrrrrrrr rrrrrrrr rrrr _ PR - _____-- -___ - { rrrrr����rrrr��rr-��rrrrrrrr����rrrrr �` /:' --- PEHN TEST: 12,062 rrrrrrrrr WATER EXISTING / `° o ; °> li r�rrrrrrLrr�rr �rr1r-t-T-v ,� rrrrrrrrr 41 Vrrrrr r1r'��r ��., - 'r SEPTIC WITNEPERFSSED RMED S.-TOWN)FBAR STA13 r(�n^C/}r SERVICE WITNESSED BY:DONNAMIORANDI,R.S.-TOWNOFBARNSTABLE Drive �i' E NOTE 1p f N \ rr -rrrr rrr rrrrr r / /y `_-- tone Over Pavement f, SE / � o IANUARY3,2008 N 1 ! �� �rrrrrrrrrrrrr f / o { l r rrrrrrrrrrrrr �/ /i j / j TEST HOLE-3 TEST HOLE-4 TEST HOLE-5 + / 1 TEST HOLE-1 TEST HOLE-2 .-r _ 12x4 EL.15.1 EL.14.7 EL.13.9 EL 13.7 L.10.8 R=1HIN \TCH O •• � II � � 4 r rrrrrrrrrrrrr •. / ---__ o r slate Patio rrrrrrrr ( l� _--__ w/Pool & spa (aprox) ftrrrrrrrrrrrrrrrr 1 C. CA CHINS f / J rrrrrrrr rrrr ;I ®e"AsN ii zz _ f 71 f f FILL FILL rrr 1 �rrrrrrrrrrrrrrrrr l _ Stone rrrrrrrr rrrrrrrr \\ / 33" 12.4 33" 12.0 FILL FILL FILL 1 Waterfall r 1 L «rrErrrrrrrrrrr rrrr \ \\ �� - Y - _ rr rrr rrrrr \\ _-__ � „r ...:............. j:: r �- ,,.✓ `'` B LAYER 1 OYR 5/6 B LAYER 1 OYR 5/6 I 1 t' rrrrr rrrrr rrr �\ 1� �\ /, f r Y rr�r�irr� �rrrrrrrrrrrrrrrr a ��� J rrrrr r m rr rrrrrr rrrrrr ' _-� o �. YELLOWISH BROWN YELLOWISH BROWN s ,✓ •''" � � 44" LOAMY SAND 11.4 44" LOAMY SAND 11.0 35" 11.0 35" 10.8 t/ rrrrrrrrt .r�1 �rrrrrrrrrrrrrrrr�rr�I� : \��\ j-- - ��--/ �a a 0 0 r \ ✓ ✓ BR Cl LAYER 10YR6/8 CI LAYER 1 OYR O8 CI LAYER 10YR6/8 CI LAYER IOYR YELLOW rrrrr t rrl I I rrrrrrrrrlr-rrrr rrr�l 'A Z to �.•,,.`\ W W B W rrr rrrr rrrr r .>r r � // 749 z m ,.....••........"..'..... � - ,,,: -- ,.... ~~-- ;' BROWNISH BROWNISH ROWNISITYII.LA 10.0 60" 5.8 rrrr r\ Sho Z r ; .✓" Fountain OWNI BROWNISITYQLO rr rr rr rr r \ {0 1[ \\ MED.SAND 52^ MED.SAND ]0.4 MED.SAND q4^ MED.SAND \�rr�\ J // f/ DOJ 0 rrr rrrrr rrrrr \ r� I Ji .• Sump } 2 Sty W/F.......r m o -� / X 25 GALLCNSEif MIN LIGHT YELLOWISH BROWN " 25 GALLONS 6M►N 30 SEC 1 ,IGNT YC OWS HBROWN BROWNISH YELOW rrrrrrrrrrrrrrrr �rr�\\ 1 n ; EL wL�lllna ✓ 52"49 <21viIN/IN 0 10.8 132" MED.SAND 3.7 44»36 <2MIN/IN 9 102 120" D.SAND 3.7 120" MED.SAND 3A5 i - rrrrrrrrrr ° \\C ,,. 1 V ..-,Y - NO CROUNDWATLRE ENCOUNTERED NO WATER LN ............... .s N(bUN GROUNDWATER CnUNTE •D COIIC / GR RL HIGH GROUNDWATER -, I e �rrf ', -"� A ,.-•� �;.. -- \'. 1LIGHTYEL OWISHBROWN ..::LIGHTYEL OWISHBROWN ''s AS OBSERVED THROUGH OlJ21ro8- t O -11 r� ! - I .. �•,l 13 » t MED.5.AND .4.1 ]2 " - Mhn s .'� g C.S _ im 'At/?3lOS�1 JI�,A'�4'.`S� C 't7�;� G I✓O �rrr`r n L wn NO, ENCOUNTERED NO GROL-NDWATL•RS1V:X?U":TL:FL•D `I WIF ° \ �• \ ` ��rfll Shed o J 2nd Sty Deck / Lawn / yC��\\ o a Wood Deck _ r n -Lawn Om,c Wolk - _ -J' \ f 24"0 C.I. Cover Ij II / :/ / - ""• --� ✓ ' r ` \t Approved Equal 9" Min. Finished all I / / ✓ ! Fr mSSe t Tank Rim4& Cover Cover / _ t + 4 1 csa - :/ -' ' Brick Patlo t t For Float Support � � '`t'•.,� � y """" '' \ Locate Junction Box Outside of Tank Walk Conduit Thru Chamber For Drift 1 - I Lawn - 1 Power & Float Cables Galy. Chair, For Drain Pum Power & Float Control E tt t _17�' SB DH fir - + d f - - Emer enc Stara a es ns o le n ccor once Find .. / r volume tn. Cover es \ Inv. 9.45 f Top Of O OX Wall = �� k+1 a. M' 2' Alarm On EI. 5.33 MercuryHoot - Bldg. &'Elec. Cod o ✓ ��� Switches - 3 Req d 5'-0" � '� i- ....--.^" �j � ,,• --_. �- -..,.. .-- •--- � - S�OF Nt f0 1 r \\ �T�� f "`�J N H y ✓ ✓ \ .e... e - Lead Pump On El. 4.70 O e Pump Tank. Sch. 40 PVC C ° -l c> / l f ' 3�2 Pum s Off El. 4.12 Precast Pump Secure PI a at To & FEMA T ' / o om O om er40 3(E 11) + f ✓ 2Threaded PipeC Chamber Al Wood :.'' 16 / Top of r i o2 Approv Myers quo pCheck Valve eWa lf-Wo EL=5.4' / T- Bottom El. 2.12 To D-Box 2 Sty W/F o �. ✓ r Z"9 3 2500 Gallon Boathouse - 6" Wash Stone Min. Pump Chamber Plan View '. r r ✓ o Q- t 2500 Gallon Not to scale cb . ... ........... °�'-� l vet-FumI :. l.ocamson to be Determined Tap Of Pump Chamber Section Detail at Time of lnstatsoastobe ', Lawn Wall EL=5.2' 3xt as Inconspicuous as Possible \\ a Not to Scale V. Top of Stone Revetment Wall EL=5.2' Top Of ~. .f"" ..�- '_'_ ..L.-- -- F.F.EL.12.90 f Wall EL=5.1' ✓ Mortared Stone W II 3x1 3x2 F.G.EL.12.00 F.G.EL.12.25(MIN.) w A r x See Note 4 (tYP) SEE NOTE 7 UYP.) Mean High Water E1=1.9' NGVD '29 Top EL.I1.50 Ver Instant'To Confitml'rior F1 To Any wad Pump Gallon D Box EL.9.80 ville � 3500 Gallon Pump Chamber Septic Tank uaeerpr"c;f App-a EL.to.w Leaching w/rwo(z)cants or Appmwd Seobnt Chamber o RWoterlxoored/S;-.d Flow Eauilizets w/n'.(2)coots of Appro-d S d-t As Required .: Ba.EL.sso ter Cl e n •' p N ,,.. IfEncemmtered Remove Bc Replace All Unsuitable Soils Within 5•of fl0 d Bedding,T"s,&BaffeLs The Outer Perimeter of The System Fii® 1f 11 h as Per min. (SNts &9) IO'Min.-Stab era%=..R Via`• 0'Min.-Fomm lion EL.3.45 sp C y� High Gtoundrvater �C' SRlLt.i A See Test Hole Developed Profile Of Proposed Septic System Not to Scale Legend: NOTES: PREPARED FOR: PREPARED BY: TI TLE: • Soils Test Pit 0 Misc Manhole Site Plan © Gas Gate ® Catch Basin CapeSurv w® Water Gate ® Drain 1.) The property line information shown wasRamsay E. and Merrilee Crain Sullivan En lneerin0 Inc. Proposed Sentll�i u/�(�rlde -0 Guy compiled from available record information. Engineering, 1" 1" 1"7 1- CB/DH Concrete Bound w/Drillhole 749 South Main Street PO Box 659 7 Parker Road O Utility Pole El LC8 Land Court Bound Osterville, 2.) The topographic information was obtained MA 02655 Osterville MA 02655 t l� � Hydrant Centerville, MA 0 SB/DH Stone Bound w/Drillhole from an on the ground survey performed on- (508)428-3344 (508)428-3115 fax (508) 420-3994 (508) 420-3995 fax 749 South Main Street OW Water Gate (round) ca esurv@ a ecod.net ■ MHB Mass Highway Bound or-between 17/JAN & 01/FE8/08. P P � Deciduous Tree ® Monitering Well w- overhead wires 0 Draft: JOD Field: RRL/DWB Z ) Bamstable (Centerville) Mass.oN 3. The datum -used is NGVD 29, a fixed mean � - -25- - Elevation contour sea level datum. 20 0 10 20 40 8 Coniferous Tree Review: PS Comp.: RRLDWB DATE: April 21, 2008 SCALE: ' 11_20, Project # 26039 Project # C247