HomeMy WebLinkAbout0194 STONEY CLIFF ROAD - Health (2) EA
ENTERVILLE
190 164
ill
UPC 12534 P
No.2.1 3L R � ,
NAiTIN���YM
i
~ Commonwealth of Massachusetts /"�P 1 �b ^�� / 7
N Title 5 Official Inspection Form �
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
194 Stoney Cliff
GM t)
Property Address
p�
Audile Fortman
Owner Owner's Name F..�
information is
required for every Centerville MA 02632 7-17-15 !
page. City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered Any
way. Please see completeness checklist at the end of the form.
A. General Information
1. Inspector:
Shawn Mcelroy
Name of Inspector
Upper Cape Septic Services
Company Name
P.O. Box 73
Company Address
E. Falmouth MA 02536
City/Town State Zip Code
1-508-495-0905 S13971
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5 (310 CMR 15.000).The system:
® Passes ❑ Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
7-17-15
Inspector's Signature Date
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
/0 # -Vs
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 17
r
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M 0 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville. MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist.Any failure criteria not evaluated are
indicated below.
Comments:
System is in good working order with no sign of failure.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Passff section need to be
replaced or repaired.The system, upon completion of the replacement or repair,as approved by
the Board of Health,will pass.
Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
*A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Swage Disposal System-Page 2 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
a
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M , 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
B) System Conditionally Passes (cont.):
❑ Observation of sewage backup or break out or high static'water level in the distribution box due
to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ Y " ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
C) Further Evaluation is Required by the Board of Health:.
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
t5ins-3113 Title 5 Official Inspection form:Subsurface Sewage Disposal System-Page 3 of 17
Commonwealth of Massachusetts
Title 5 Official. Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
4 M , 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. Cityfrown State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health(and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well**.
Method used to determine distance:
**This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis must
be attached to this form.
3. Other:
D) System Failure Criteria Applicable to All Systems:
You must indicate "Yes"or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to.the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6° below invert or available volume is less
than '/2 day flow
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 4 of 17
I
Commonwealth of Massachusetts
W Title 5 Official, Inspection Form
a Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
,M y 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ E . The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
t ❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303,therefore the system fails.The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or,"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area— IWPA)or a mapped Zone II of a public water supply well
If you have answered "yes"to any question in Section E the system is considered a significant threat,
or answered "yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
t5ins-3113 Title 5 Official Inspecbon Form:Subsurface Sewage Disposal System-Page 5 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. Cityrrown• State Zip Code Date of Inspection
C. Checklist
Check if the following have been done. You must indicate "yes" or"no"as to each of the following:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components,pumped out in the previous two weeks?
❑ ® Has the system received normal flows in the previous two week period?
❑ ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
® ❑ Were as built plans of the system obtained and examined? (If they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems.
The size and location of the Soil Absorption System (SAS) on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) [310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
Number of bedrooms (design): 4 Number of bedrooms(actual): 4
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 440
t5ins-3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 6 of 17
Commonwealth of Massachusetts
R. Title 5 Official Inspection Form
gSubsurface Sewage Disposal System Form -Not for Voluntary Assessments
M 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. CitylTown State Zip Code Date of Inspection
D. System Information
Description: _
Number of current residents: 0
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No
information in this report.)
Laundry system inspected? ❑ Yes ® No
Seasonal use? ® Yes ❑ No
Water meter readings, if available (last 2 years usage (gpd)):
Detail:
Sump pump? ❑ Yes ® No
Last date of occupancy: 7-2015
Date
Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow(based on 310 CMR 15.203): Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present? ❑ Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available:
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 7 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M e'� 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17=15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use: Date
Other(describe below):
General Information
Pumping Records:
Source of information: Owner--pumped 9-2014
Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped: I gallons
How was quantity pumped determined?
Reason for pumping: Maintenance
Type of System:
® Septic tank,distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Altemative technology.Attach a copy of the current operation and
maintenance contract (to be obtained from system owner) and a copy of latest
inspection of the I/A system by system operator under contract .
❑ Tight tank.Attach a copy of the DEP approval.
❑ Other(describe):
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17
Commonwealth of Massachusetts
W Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
,M , 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed (if known) and source of information:
1999
Were sewage odors detected when arriving at the site? ❑ Yes ® No
Building Sewer(locate on site plan):
Depth below grade: 24"feet
Material of construction:
® cast iron ® 40 PVC ❑other(explain):
Distance from private water supply well or suction line: feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
Good condition.
Septic Tank(locate on site plan):
Depth below grade:
16"
feet
Material of construction:
® concrete ❑ metal ❑fiberglass ❑ polyethylene . ❑ other(explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Dimensions: 1000 gal
Sludge depth:
12"
t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
M 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank(cont.)
Distance from top of sludge to bottom of outlet tee or baffle
20"
Scum thickness
1"
Distance from top of scum to top of outlet tee or baffle
6"
Distance from bottom of scum to bottom of outlet tee or baffle
15"
How were dimensions determined? Tape
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tank is in good condition with baffles installed and no sign of leakage.
Grease Trap (locate on site plan):
Depth below grade: feet
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping: Date
t5ins•3/13 Tide 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 17
Commonwealth of Massachusetts
= Title 5 Official Inspection Form
" Subsurface Sewage Disposal System Form =Not for Voluntary Assessments
194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Capacity:
gallons
Design Flow: .
gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments (condition of alarm and float switches, etc.):
*Attach copy of current pumping contract (required). Is copy attached? ❑ Yes ❑ No
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 11 of 17
Commonwealth of Massachusetts
Title 5 official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M s 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville" MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Distribution Box (if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert 0
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Good condition with water at working level and no sign of back-up from field.
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No*
Alarms in working order: ❑ Yes ❑ No*
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
* If pumps or alarms are not in working order, system is a conditional pass.
Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
t5ins-3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal.System Form -Not for Voluntary Assessments
194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Type:
❑ leaching pits number:
® leaching chambers number: 5-Infiltrators
❑ leaching galleries number:
❑ leaching trenches number, length:
❑ leaching fields number, dimensions:
❑ overflow cesspool number:
❑ innovative/altemative system
Type/name of technology:
Comments(note condition of soil, signs of hydraulic failure;level of ponding, damp soil, condition of
vegetation, etc.):
Infiltrator leach field in good wonting order with no sign of back-up into d-box or surrounding stone.
Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth—top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow ❑ Yes ❑ No
t5ins-3/13 Title 5 Official Inspection Form:Subsurface' wage Disposal System-Page 13 of 17
Commonwealth of Massachusetts
w Title 5 Official Inspection , Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
Privy (locate on site plan):
Materials of construction:
Dimensions
Depth of solids
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below:
® hand-sketch in the area below
❑ drawing attached separately
' 2
P .d
13 t
t5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17
r -
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M 194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Site Exam:
❑ Check Slope
❑ Surface water
❑ Check cellar
❑ Shallow wells
Estimated depth to high ground water: 12'+
feet
Please indicate all methods used to determine the high ground water elevation:
® Obtained from system design plans on record
If checked, date of design plan reviewed: Date
® Observed site (abutting property/observation hole within 150 feet of SAS)
® Checked with local Board of Health -explain:
® Checked with local excavators,.installers- (attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
Original design plans show no groundwater at 12'.
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5ins-3113
Title 5 Official Inspection Form:Subsurface Sewage Disposal System Page 16 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
194 Stoney Cliff
Property Address
Audile Fortman
Owner Owner's Name
information is required for every Centerville MA 02632 7-17-15
page. City/Town State Zip Code Date of Inspection
E. Report Completeness Checklist
® Inspection Summary:A, B, C, D, or E checked
® Inspection Summary D (System Failure Criteria Applicable to All Systems) completed
® System Information—Estimated depth to high groundwater
® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
t5ins•3113 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 17
-------------
TOWN OF BARNSTABLE
' LOCATION
SEWAGE # —
In—
ASSESSOR'S MAP & LOT
VILLAGE��-,
INSTALLER'S NAME&PHONE NO.
SEPTIC TANK CAPACITY �v \ �`}
LEACHING FACILITY: (type)
\� N 5 (size) L
NO.OF BEDROOMS 1 , y ^�" J
BUILDER OR OWNER
PERMTTDATE: �-I 1'2 I `'1� COMPLIANCE DATE:
Separation Distance Between the: , Feet
Maximum Adjusted Groundwater Table and Bottom of Leaching Facility
Private Water Supply Well and Leaching Facility (If any wells exist
,3 r-4 Feet
on site or-within 200 feet of leaching facility)
Edge of Wetland and Leaching Facility (If any wetlands existc� Feet
within 300 feet of leaching facility)
Furnished by
I
P
TAW .� TABLE
s WA.GE A;VIL
t, � � f v ul l a sFss�n.s M Loy' ,..,
INSTA3,a Xlkl;DTAIE&P�t�TI+YE O
SEIF'I'�C -rA'I'M LA'ACV
LFACIi}1►�G 1��,.aLur , (gyp ) -
i
NO.01FIBSOM
P Q mWi�CS2 ------
row
mlilcr
Sepa tianxstaai3Pivr�en
Maximum d}ustaclGkpuracJwatav'k'Wta i116 1�oit6inufLeuuhin l ��ility
k iv 4e WaA r SWpialy 1u�1;a��c@ l�caa�in �nataty C as�y:Vic r exist
ata ait�s"ac avithin:�pQ felt of 1at�ciu��facility) ;
pci�r cy�'�`� i�aY�d aid Leae�ta�i~ c�tity��E uriy wetiandti eRfs4 a
viitain Mo feet pf Wei 1h PuG `c' .
�ue«i�h�sti:ty z
� ����
� -
O c �
j
b �
� a �
C f
�_C aS6`� /� -� �s 6�
��
�„
��
TOWN OF BARNS{T�ABLE
LOCATION 19 Q d SEWAGE #
VILLAGE 4,e�P n r y 1 ASSESSOR'S MAP & LOT b 4
INSTALLER'S 14AME&PHONE NO. 3- CV 1' , 2-- S
SEPTIC TANK CAPACITY
LEACHING FACELITY: (type). "" -�� ``` (size) Al
NO.OF BEDROOMS_.(4 U
BUILDER OR OWNER' _.�glc�� c J C 1 WN
PERMITDATE: I U I q�) COMPLIANCE DATE:
Separation Distance Between the:
Maximum Adjusted Groundwater Table and Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist n l
on site or-within 200 feet of leaching facility) I y Feet
Edge of Wetland and Leaching Facility(If any wetlands exist 0
within 300 feet of leaching facility) �"`� Feet
Furnished by
sA- (p
r
No. l ( / Z Fee i' //
THE COMMONWEALTH OF MASSACHUSETTS
Entered in computes `Yes
PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE., MASSACHUSETTS
Application for Migaal *pgtem Construction Vermit
Application for a Permit to Construct( )Repair(Vupgrade( )Abandon( .) ❑Complete System ❑Individual Components
Location Address or Lot No. i ci o — I(pq _VA 3 3 Owner's Name,Address and Tel.No.
�V�A 'vrAm�1
Assessor's Map/Parcelh Cv \
Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No.
lw�k R-C)
Type of Building: �p�
Dwelling No.of Bedrooms Lot Size sq.ft. Garbage Grinder( )
Other Type of Building No. of Persons Showers( ) Cafeteria( )
Other Fixtures
Design Flow gallons per day. Calculated daily flow gallons.
Plan Date Number of sheets Revision Date
Title
Size of Septic Tank Type of S.A.S.
Description of Soil
Nature of Repairs or Alterations(Answer when applicable) < < `, 5
.b t C
.xJ4 IL
Date last inspected:
Agreement:
The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance with the provisions of Title 5 of the Environmental Cfo place the system in operation until a Certifi-
cate of Compliance has been iss e by this Board Health.
Signed Date
Application Approved by Date ^/
Application Disapproved for the following reasons
Permit No. — Z Date Issued
No. / Z USG Fee �.
..�
THE COMMONWEALTH OF MASSACHUSETTS Entered in computer:
_ k Yes
PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE., MASSACHUSETTS
01pprication for Mioponl *pgtem Construction j3ertnit
Application for a Permit to Construct( )Repair(Upgrade( )Abandon( ) ❑Complete System ❑Individual Components
Location Address or Lot No. kc, •-, 33 Owner's Name,Address and Tel.No.
Assessor's Map/Parcel
I� Ste, C N-
Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No.
CZd
Type of Building:
Dwelling No.of Bedrooms y1 _ Lot Size sq. ft. Garbage Grinder( )
Other Type of Building T No.of Persons Showers( ) Cafeteria( )
Other Fixtures
Design Flow gallons per day. Calculated daily flow gallons.
Plan Date Number of sheets Revision Date
Title
Size of Septic Tank Type of S.A.S.
Des`cr�iption of Soil
Nature of Repairs or Alterations(Answer when applicable) 5<< < sv S
'b
Date last inspected:
Agreement:
The undersigned agrees-to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance;with the provisions of Title 5 of the Environmental C e.VKlTfot to place the system in operation until a Certifi-
cate of Compli'ance-has been is e by this Board Healt G
Signed Date
Application Approved by Cr Date —/6
Application Disapproved for the following reasons `: r
� w
~ Permit NO. »Z Date Issued
———— ————————————'—————————————————————
THE COMMONWEALTH OF MASSACHUSETTS
BARNSTABLE, MASSACHUSETTS
` Certificate of Compliance
THIS IS TO CERTIFY, that the On-site Sewage Disposal System Constructed( )Repaired (V'j Upgraded( )
Abandoned( )by v k 6 to)rA M wt
at C "rc 2 C�` ,-z, h Rzdated
n constructed in accordance
with the provis ns of Title 5 and the for Disposal System Construction Permit No. '
Installer CrJ \ 1(., Designer a>
The issuance of this pe 't shall not be construed as a guarantee that the systemtll�.f^unction as de ign4) / /0
Date Inspector il� �
---+�}------------------------------------=�—
No. 77 �19 Z- Fee S
THE COMMONWEALTH OF MASSACHUSETTS
PUBLIC HEALTH DIVISION - BARNSTABLE., MASSACHUSETTS
Migogaf *potem Construction Vermit
Permission is hereby granted to Construct( )Repair(' Up rade( )Abandon( )
System located at Z�'1Z� 1-►�...e_�, C4 t Cc 2r A EIl e_
and as described in the above Application for Disposal System Construction Permit. The applicant recognizes his/her duty to
comply with Title 5 and the following local provisions or special conditions.
Provided:Construction must be completed within three years of the date of this-permit.
cy q
Date: -`�l / / Approved by � �'
1/6199
NOTICE: This Form Is To Be Used For the Repair Of Failed
Septic Systems Only. -
CERTIFICATION OF SKETCH AND APPLICATION FOR A DISPOSAL
WORKS CONSTRUCTION PERMIT (WITHOUT DESIGNED PLANS)
I, �40� M�cz,.l��� , hereby certify that the application for disposal works
construction permit signed by me dated Q-I ` �' (q"� , concerning the
property located at C C�Y meets all of the
following criteria:
• The failed system is connected to a residential dwelling only. There are no commercial or business
uses associated with the dwelling.
• The soil is classified as CLASS I and the percolation rate is less than or equal to 5 minutes per inch.
• There are no wetlands within 100 feet of the proposed septic system
• There are no private wells within 150 feet of the proposed septic system
• There is no increase in flow and/or change in use proposed
• There are no variances requested or needed.
• The bottom of the proposed leaching facility will not be located less than five feet above the
maximum adjusted groundwater table elevation. [Adjust the groundwater table using the Frimptor
method when applicable]
• If the S.A.S.will be located with 250 feet of any vegetated wetlands, the bottom of the proposed
leaching facility will not be located less than fourteen(14)feet above the maximum adjusted
groundwater table elevation,
Please complete the following:
A) Top of Ground Surface Elevation(using GIS information)
B) G.W. Elevation +the MAX.High G.W. Adjustment t
DIFFERENCE BETWEEN A and B
rC� I
SIGNE; . DATE:
[Sketch proposed plan of system on back].
q:health folder:cent -
0 0
Y ._?
L