HomeMy WebLinkAbout0008 TARAMAC ROAD - Health 11
8 Taramac Road
Centerville
A 146 012
S0 -
UPC 10259
No. H163OR g4.
M&stoma# 460
TOWN OF BARNSTABLE , C.
LOCATION �� ��R 114A C AD SEWAGE # Z G 02� ��•�
VILLAGE 1//1L e ASSESSOR'S MAP & LOT
INSTALLER'S NAME&PHONE NO. 422 C 0 41 5 e'er
SEPTIC TANK CAPACITY /o e D r o L,D
LEACHING FACILITY: (type) ,2— IJ q)e jV 2LL 3� (size)
NO. OF BEDROOMS (-7
BUILDER OR OWNER f�I4 SIe iA
PERMITDATE: a COMPLIANCE DATE: IT��
Separation Distance Between the:
Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist .
within 300 feet of leaching facility) Feet
Furnished by
f
GJ �
J
IS�'
VAI b�J ;
Fee$50.4Ye -//
THE COMMONWEALTH OF MASSACHUSETTS
Entered in computer:
PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE., MASSACHUSETTS
01pplication for Miquar 6potem Construction Permit
Application for a Permit to Construct( )RepairAXA Upgrade( )Abandon( ) ❑Complete System ❑Individual Components
Location Address or Lot No. 8 Taramac Road Owner's Name,Address and Tel.No.Robert Gladstein
CAent�rMvpi,llg,Mass. �L �o�� 8 `Taramac Road Centerville,Mass.
ssessor s a arce 02632
Installer's Name,Address,and Tel.No.5 0 8—7 7 5—3 3 3 8 Designer's Name,Address and Tel.No.5 0 8—2 7 3—0 3 7 7
J.P.macomber & Son Inc. JC Engineering 5 Roundhill BLVD
East Wareham,Mass. 02538
Type of Building:
Dwelling XX No.of Bedrooms 2 Lot Size sq.ft. Garbage Grinder( )
Other Type of Building No.of Persons Showers( ) Cafeteria( )
Other Fixtures
Design Flow 3,C;0 gallons per day. Calculated daily flow 2 X 1 1 0=2 2 0 gallons.
Plan Date Number of sheets Revision Date
Title
Size of Septic Tank Type of S.A.S.
Description of Soil
Nature of Repairs or Alterations(Answer when applicable) A rl rl i n s tom] 500 gallon l a a r-h i n g
chambers rucked in 4 ' of 1 ;�'[" stone_ 25 'X12' 9"X2 '
Date last inspected:
Agreement:
The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance with the provisions of Title 5 of the E vironinental Cod and not to place the system in operation until a Certifi-
cate of Compliance has been issu, by this d_ h.
Signed Date
Application Approved by Date
Application Disapproved t e following rea n
Y
Permit No. Date Issued
THE COMMONWEALTH OF MASSACHUSEi S
BARNSTABLE, MASSACHUSETTS ' t
Certificate of Compliance
THIS IS TO CERTIFY,that the On-site Sewage Disposal System Constructed( )RepaireM. X,XUpgraded( )
Abandoned( )by J.P.Macomber & Son Inc.
at R Po=r3 rei 119, ha been constructed in accordance
with the provisions of Title 5 and the for Disposal System Construction Permit No r__Md dated
Installer J.P.Macomber & Son Inc. Designer JC ngineering INC
The issuance of 's 'ermit shall not be construed as a guarantee that the sys em will f�'nction as ddsigne�d.---
Date I 0 Inspector �tNyl
— ——— ------------- ysy-------------
N..-4 /V �' J� — 1 Fee$50.00
a /
THE COMMONWEALTH OF MASSACHUSETTS
v
PUBLIC HEALTH DIVISION - BARNSTABLE., MASSACHUSETTS
MoogarfOtem Conotruction Permit
Permission is hereby granted to Construct( )Repair(Xy)Upgrade( )A n
( ) -
Systemlocatedat R MaXama#- RoAd rg,ni-or%ti1 le,Mass
and as described in the above Application for Disposal System Construction Permit.The applicant recognizes his/her duty to
comply with Title 5 and the following local provisions or special conditions.
Provided:Constructi eted within three years of the date of ?i—
Date: Approved b > �
� � PP Y ,
Fee$5 0.0 0
' THE COMMONWEALTH OF M_ASSACHUSETTS k., Entered in computer:
PUBLIC HEALTH DIVISION -TOWN ORBARNSTABLES MASSACHUSETTS, Yes.
Rpplication for �Digoq;af *pgtem Cougtruction Permit
Application for a Permit to Construct( )RepaifAX.)o Upgrade( )Abandon( ) ❑Complete System ❑Individual Components
Location Address or Lot No. 8 Taramac Road Owner's Name,Address and Tel.No.Robert Gladstein
Centerri�11 ,Mass. 8 `Taramac Road Centerville,Mass.
Assessors ap 02632
Installer's Name,Address,and Tel.No.5 0 8—]7 5-3 3 3 8 Designer's Name,Address and Tel.No.5 0 8-2 7 3-0 3 7 7
J,P.macomber & Son Inc. JC Engineering 5 Roundhill BLVD
.13ox 66 CenterVi_jjP,Maqc_;_0?632East Wareham,Mass.02538
Type of Building:
Dwelling XX No.of Bedrooms 2 Lot Size sq.ft. Garbage Grinder( )
Other Type of Building No.of Persons Showers( ) Cafeteria( )
Other Fixtures � .
Design Flow r,f1 gallons per day. Calculated daily flow 2 X 1 1'0=2 2 0 gallons.
Plan Date-,"' "~ Number of sheets Revision Date
Title
Size of Septic Tank Type of S.A.S.
Description of Soil-
Nature of Repai or Alterations(Answer when applicable) AAr1i n two 5aQ gallon leaching
chambers Lacked in 4 ' of 1lt" stone.25'X12: 9"X2'
Date,last inspected:
Agreement:
7 . The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance with the provisions of Title 5 of the E vironmental Cod rand not to place the system in operation until a Certifi-
cate of Compliance has been issue y by this d
- Signedr Date 11 /5 0 2/
"Application Approved by/ Date
•�.; Application Disapproved t e following reas, n�
n
Permit No. Date Issued t
f .
y -~ TOWNOF BARNSTABLE �L-
i
LOCATION e T/R A114 A C AP SEWAGE #A G 02
VILLAGE C eAlreA Y/LG C / 0 2
ASSESSOR'S MAP & LOT 6" I
INSTALLER'S NAME&PHONE NO.�J, �lr 4 C 0/N 5 eA,'
SEPTIC TANK CAPACITY /-0 e D 0 L,D
LEACHING.FACILITY: (type) �r rJ eLL 3, (size) I3 `>L A
NO. OF BEDROOMS
A
BUILDER OR OWNER I4 S� "n
PERMITDATE: U COMPLIANCE DATE:
{
Separation Distance Between the:
Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist .
within 300 feet of leaching facility) Feet
Furnished by
0\
57
�y'
J
3
✓yams �i�
5" DIA. OUTLET(S) FINISH GRADE OVER CHAMBERS = 95.0'-96.23' GENERAL NOTES
/TOP OF FOUNDATION = 101 .6' REMOVABLE COVER SLOPE @ 2% MIN. OVER SYSTEM
, 4" SCHEDULE 40 PVC MIN SLOPE 1% 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE
FINISH GRADE OVER D-BOX= 95.8 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
95.0'-96.0' 2" OF 1/8" TO 1/2" DOUBLE WASHED STONE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE
FINISH GRADE @ FND. EL.= 97 5� FINISH GRADE OVER TANK EL- - - -
__ _ _..---.__. . . . _ _. _ __f ___. . _ __ .__ _ ___ _ - _ _. _ _ _ _ _ _ _____-- - __ _ ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES.
20" MIN. ACCESS COVER TOP OF SAS - 93.23' PLACE RISERS ON ALL CHAMBERS
36"MAX. 9" MIN. TO 6" OF FINISHED GRADE 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD
(TYPICAL FOR 3) 92.40' 36" MAX. OF HEALTH AND THE DESIGN ENGINEER.
EXISTING 4" � BREAKOUT EL = 92.90 �„
PVC PIPE 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL
2" DROP MIN. PROVIDE WATERTIGHT BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED.
6" 3" 3" DROP MAX. 3" 9" _ JOINTS (TYIP.) O
00 00 O 00000 000 O
4" PVC IN FROM O oo 0 o0 4. EL PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE LESS THAN
ELEVATION = 92.90' FOR A DISTANCE OF 15'AROUND THE PERIMETER OF THE SAS. UNLESS
93.00' 0 14" �92.75' SEPTIC TANK 4" PVC OUT TO o0 000 00 0o I A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF
LEACHING FACILIITY T o00 0 0 0 I THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
MI i� 2' oo CD CD � oo� 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM.
95.37 OUTLET TEE 92.67 MIN. 92.50
6" CRUSHED 'STONE L
oo 00 00 0 0 0 � 0 00 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
23.4' 22 ZABEL FILTER OVER MECHANICALLY 40 4 7. LOCAL BOARD OF HEALTH TO BE NOTIFIED
MODEL#A1801 HIP COMPACTED BASE
-F� �� � PRIOR TO BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND
(GAS BAFFLE ON 4
BOTTOM) 5 25' - ~� 4.9 - � READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED
OUTLET DISTRIBUTION BOX (TYP.) WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH.
TO BE INSTALLED ON A LEVEL STABLE ' GROUND WATER ELEV.- 83.97 12.9'
N CONCRETE SEPTIC TANK BASE. FIRST TWO FEET OF OUTLET 90.40
PROPOSED 1 GALLO C PIPES TO BE LAID LEVEL. 2 500 GAL. CHAMBERS 5' MIN. 8. ELEVATIONS BASED ON ASSUMED DATUM OF 100.3' MSL OBTAINED
LENGTH 10'6" WIDTH 5''8" DEPTH 5'7" CROSS SECTION VIEW
FROM CORNER OF DRIVEWAY AS SHOWN ON PLAN.
TYPICAL CHAMBER PROFILE DETAILS CHAMBER END VIEW
SEPTIC TANK PROFILE DISTRIBUTION BOX DETAIL 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
NOT TO SCALE THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE
NOT TO SCALE
NOT TO SCALE ! - -- --- - - -- AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY
TEST PIT DATA DISCREPANCIES TO THE DESIGN ENGINEER.
10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONCRETE
m .-r
INSPECTOR: STRUCTURES SHALL BE MADE WATERTIGHT.
N.
SOIL EVALUATOR: Samuel Philos Jensen 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR
¢ .y ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN
� t� �r k� DATE: October 2. 2002
rn / m ' " SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
kr
<- 'r3,� ' " TEST PIT#: 1
' t a� "" 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS
°' 'Am w- { ;' "' ELEV TOP = 94.97' LOCATED UNDER PAVEMENT, DRIVES OR TRAVELED WAYS IN WHICH
E.
ri .� �� ( ELEV WATER= >1 V BGS
� CASE THEY SHALL WITHSTAND H-20 LOADING.
` �r� ti � � ,5; PERC RATE = 2 Min/In (Assumed) � 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND
o Pl �� '`� " �� �� FINES.
co 'I"
' DEPTH OF PERC = N.A.
14 WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM. SUBSOIL AND
� r
.
per '°& g TEXTURAL CLASS: 1 UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES
- - -- OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN
COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN
' ACCORDANCE WITH 310 CMR 15.255(3).
0 94.97'
Loam Sand 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES
O-A y
10YR 4/2 FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK.
„r
4" 94.64' 16. PROPOSED PROJECT IS LOCATED WITHIN:
s �. Loamy Sand
ASSESSORS MAP 146 PARCEL 12
B 10Y R 5/8
jIX
b y 17. OWNER OF RECORD: ROBERT S. GLADSTEIN
19" 93.39'
ADDRESS: 639 GRANITE STREET
� r � r, BRAINTREE, MA 02184
� d _
yw. �t " M-C Sand
"%i ro k� h " r. 2 5Y 6/6
C PL,�N REFERENCE: BOOK 223 PAGE 139
19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
f. f No Grcundwater or
.0, f, 6"OAK".
�1 12 PINE Weeping Observed 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY
Z LOCUS PLAN FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
�o� 132" 83.97'
c 6"PIN 24"PINE a FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE.
SCALE: 1" = 1000'
12°PINE� o INSTALL TWO 500-GAL _
B.M. 15"MAPLE
$"PINE
Corner Driveway 2S INFILTRATION CHAMBERS
�^.
0- TP1 - SIG DATA
Elev. = 100.3' ^ry. r
Assumed O :: 7 289, _---- ---0ISTRIBUTIONBOX `
10"PINE ' $"PINE - X 50
EXISTING SPOT GRADES
SHED 5Q EXISTING CONTOUR
_ 1 p"OAK 12"PIN.
----- PRO 1500
GA N SE STANK NUMBER OF BEDROOMS (ASSESSORS) 2 50 PROPOSED SPOT GRADES
$"pq ? XISTING CESSPOOL NUMBER OF BEDROOMS (DESIGN) 3 (MIN PER TITLE V)
8 _ _ `V $"PINE TO BE PUMPED AND NUMBER OF PERSONS 2 �0� PROPOSED CONTOUR
CP FILLED WITH CLEAN SAND DESIGN FLOW 110 GAL/DAY/BEDROOM E../T/C EXISTING ELECTRICAL UTILITIES
s'cHEf�rlr
h 30' AK I, L TOTAL DESIGN FLOW 330 GAL/DAY GAS EXISTING GAS LINE
DECK p , r
Cb �� _J - EXISTING WATER LINE
\ f #8 1 . , DESIGN FLOW X 200 % = 660 GAL/DAY
2 � �� �- TEST PIT LOCATION
< EXISTING �t USE 1500 GALLON SEPTIC TANK
�P BEDROOM , `v��� �Q� (MINIMUM PER TITLE V) O PROPOSED 1500 GALLON SEPTIC TANK
� � J� DWELLING `"
N .
��� T.O.F. - 101.6' ,, INSTALL 2- 500 GAL. CHAMBERS
4" SOLID SCHEDULE 40 PVC PIPE
+co l �� �` SIDEWALL CAPACITY DISTRIBUTION BOX
�' �; ? (L+W) (2 SIDES) (2' HIGH) (.74 GPD/S.F.) = GAL/DAY
61, MAP 146 ,. 7 y ti
• (25' + 12.9') ( 2 ) (2' ) ( .74 GPD/S.F.) = 112.2 GAL/DAY C,O� 500 GAL. LEACHING CHAMBER
� of PARCEL 12
4r. 20 600 SQ. FT.±
BOTTOM CAPACITY
(LENGTH x WIDTH) (.74 GPD/S.F.) = GAL/DAY
(25 x 12.9) (.74 GPD/S.F.) = 238.7 GAL/DAY
REV. DATE BY APP'D. DESCRIPTION
PROPOSED SEPTIC SYSTEM UPGRADE
\ < -� �,� PQ TOTALS: PREPARED FOR:
160 \ � ,73 N�2 23a �OVCI� TOTAL NUMBER OF CHAMBERS 2 ROBERT GLADSTEIN
�2.86' " � LP TOTAL LEACHING AREA 474.2 SQ. FT.
p, 9 X�" VAN PG l 350.9 GAL./DAY LOCATED AT
OG ` q�.�Mr_y� - �x- X-�x""X� 7,_
\V` TOTAL LEACHING CAPACITY
FNT '� e _ P 8 TARAMAC ROAD
CENTERVILLE, MA 02632
Q SCALE: 1 INCH = 20 FT. DATE: OCTOBER 16, 2002
0 10 20 40 80 FEETI
N or�LSD
JOHN L.
j PREPARED BY
CH JRRCHILL Um' JC ENGINEERING, INC.
No. 41W7 5 ROUNDHILL BLVD.
SSA EAST WAREHAM, MA 02538
LAN � �.�^ _ _ -SITE P 508.273.0377
Drawn By. JLC Designed By: JLC Checked By: JLC JOB No.305
SCALE: 1"=20'