0790 IYANNOUGH ROAD - PLANS (37)
GENERAL NOTES : n0. I REVISIONS DATE _-, GENERAL-- --�- 1 j 19/9 1 CONTRACTOR TO FURNISH ALL LABOR AND MATERIALS NECESSARY FOR A COMPLETE INSTALLATION AS DETAILED HEREIN. EACH CONTRACTOR SHALL RESPECT THE WORK OF OTHER CONTRACTORS AND IS RESPONSIBLE FOR AND LIABLE TO _ REPAIR OR REPLACE ANY DAMAGE CAUSED BY HIS WORK. 2. STORAGE: THE CONTRACTOR SHALL PROVIDE ON-SITE, WEATHER PROTECTED STORAGE. 3 CODES ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, THE STATE FIRE PREVENTION REGULATIONS AND ALL APPLICABLE NFPA CODES AND STANDARDS (LATEST EDITIONS). - THE CONTRACTOR SHALL PROTECT AND INDEMNIFY THE OWNER AND THE ARCHITECT AGAINST ANY CLAIM OR LIABILITY ARISING FROM VIOLATION OF ANY SUCH CODE OR REGULATION 4 THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS, INSPECTIONS, AND APPROVALS. QUALITY: WORKMANSHIP SHALL BE OF THE HIGHEST TYPE, AND MATERIALS USED OR SPECIFIED TO BE OF THE BEST • QUALITY THAT THE MARKET AFFORDS. ALL INSTALLATIONS AND APPLICATIONS SHALL CONFORM TO THE ' O 1 w �� MANUFACTURER'S SPECIFICATIONS. 6 COORDINATION OF THE WORK: ALL TRADES TO COORDINATE THEIR WORK THROUGH THE OWNERS REPRESENTATIVES. ,� N 7. MECHANICAL TRADES: THE MECHANICAL AND ELECTRICAL TRADES SHALL INSTALL THEIR WORK AS RAPIDLY AS THE O ® z �- OTHER WORK PERMITS, AND SHALL COMPLETE THE WORK BY THE TIME THE OTHER TRADES HAVE FINISHED. 8 EXAMINATION OF SITE AND DOCUMENTS: THE CONTRACTOR, BEFORE SUBMITTING HIS PROPOSAL, SHALL VISIT THE SITE ino AND EXAMINE FOR HIMSELF ALL CONDITIONS AND LIMITATIONS WHICH AFFECT THE CONTRACT. HE SHALL CAREFULLY a EXAMINE ALL CONTRACT DOCUMENTS TITLES AND SUBDIVISIONS IN THESE DOCUMENTS ARE FOR CONVENIENCE, AND NO REAL OR ALLEGED ERRORS IN ARRANGEMENT OF MATTER SHALL BE REASON FOR OMISSION OR DUPLICATION BY ANY CONTRACTOR. • Pp G s 9 SEPARATE CONTRACTS: THE OWNER RESERVES THE RIGHT TO LET OTHER CONTRACTS IN CONNECTION WITH THE WORK I , THE GENERAL CONTRACTOR SHALL AFFORD OTHER CONTRACTORS REASONABLE OPPORTUNITY FOR THE EXECUTION OF w THEIR WORK AND SHALL PROPERLY CONNECT AND COORDINATE HIS WORK WITH THEIRS. Rt It 10. GUARANTEE: ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE ^' OF FINAL ACCEPTANCE UNLESS OTHERWISE SPECIFIED FOR A LONGER PERIOD OF TIME. 1 1 TRASH REMOVAL: EACH CONTRACTOR SHALL PROVIDE TRASH REMOVAL. AT THE END OF EACH DAY, EACH ' D a e . 132 Al 0 oa CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE. AND/OR WITHIN THE BUILDING AREA. CONSTRUCTION / Q c,o AREA SHOULD BE SWEPT CLEAN. IF TRASH AND DEBRIS ARE NOT REMOVED, THE OWNER MAY (AT HIS OPTION) PAY FOR ITS i/ /] ! �'� •` x REMOVAL AND BACK CHARGE THE CONTRACTOR 4 _ 12 THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO WALLS, FLOORS, CEILINGS, FURNITURE OR FURNISHINGS, /, D Ira Ir o ETC. ANY DAMAGE WROUGHT DUE TO CONSTRUCTION SHALL BE RETURNED TO THE ORIGINAL CONDITION AT NO EXPENSE TO THE OWNER 13. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND REPORT ANY DISCREPANCY TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 14. ALL GYPSUM BOARD TO BE TYPE "X". 5/8" FIRE CODE, MOISTURE RESISTANT TYPE "X", 5/8" FIRE CODE OR AS p H nis MA INDICATED ON THE DRAWINGS. 0 D 15 THE GENERAL CONTRACTOR SHALL COORDINATE THE LOCATION AND SIZE OF OPENINGS FOR VENTS, PIPES, INSERTS, BOXES, HANGERS, ETC 16. GENERAL CONDITIONS: THE GENERAL CONDITIONS FOR THIS CONTRACT SHALL BE AIA--201 1997 EDITION EXCEPT AS HEREIN AMENDED 17. ALL SECTIONS, DETAILS, MATERIALS, METHODS, ETC. SHOWN AND/OR NOTED ON ANY PLAN OR SECTION SHALL APPLY TO ALL OTHER SIMILAR LOCATIONS UNLESS OTHERWISE NOTED 18, THE GENERAL. CONTRACTOR SHALL SAFELY SHORE, BRACE, OR SUPPORT ALL WORK AS REQUIRED, THIS WORK SHALL i BE THE FULL RESPONSIBILITY OF THE CONTRACTOR, AND NO ACT, DIRECTION, OR REVIEW OF ANY SYSTEM OR METHOD BY THE ARCHITECT SHALL RELIEVE THE CONTRACTOR OF THIS RESPONSIBILITY. 19. ALL WORK 15 NEW UNLESS OTHERWISE NOTED. 20. IT IS NOT THE INTENT OF THESE DRAWINGS TO SHOW NOR INDICATE ALL FASTENING OR FRAMING TECHNIQUES AND/OR ya t 'DEVICES, QR TQ ShiOW ALL, CO�IDLTI�?NS pRES1wNT:- �I � - -- 21. FRONT DOOR CYLINDER TO BE FALCON FIGURE 8 TYPE. Via;; 4 22. G.0 RESPONSIBLE FOR CLEANING OF THE PREMISES BEFORE TURNOVER TO OWNER, READY TO OPERATE CONDITION. 23. ALL* INTERIOR FINISHES AND fURN`ISHIIvGS FOR"CEILINGS,. WALLS AND-FLOORS S*iALL BE. GL.AS;; 1 WITH A F LAME SPREAD RATING OF 0 TO 25 a r 24. SUBMIT SAMPLES OF ALL PAINTS, STAINS, AND WALL MATERIAL FOR APPROVAL BY THE OWNER PRIOR TO APPLICATION. 25, UNLESS OTHERWISE NOTED, ALL FRAMING AND FINISH LUMBER ARE SIZED IN NOMINAL DIMENSIONS. � ..m,...• 26. CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITIES AND REROUTE AS REQUIRED. 27. BEFORE COMMENCING WORK, THE GENERAL CONTRACTOR WILL MEET WITH THE APPOINTED OWNERS REPRESENTATIVE OUTLINE PHASING OF CONSTRUCTION AND DISPOSITION OF EXISTING CONSTRUCTION MATERIALS, DRAWING LIST . FURNITURE, FURNISHINGS AND EQUIPMENT. CONSULTANTS : S. GENERAL CONTRACTOR TO PROVIDE ALL MEANS TO SECURE AND PROTECT CONSTRUCTION AREA FROM THE PUBLIC 29. ALL PIPING, CONDUIT, BX CABLE AND SIMILAR CONSTRUCTION WILL BE EITHER LOCATED INSIDE A WALL OR INSULATED WITH A MINIMUM 3/4" SPACE FROM THE WALL OR SEALED TO THE WALL 30. NOT USED V) Q 31, ALL ANGULAR OPENINGS IN CONSTRUCTION WILL BE SEALED TO WITHIN 1/32". 32. NOT USED 0 33. ALL WOOD BLOCKING TO BE PRESSURE TREATED OR FIRE RETARDANT, Z CV 34 ALL PLYWOOD TO BE FRS(FIRE RETARDANT TREATED). PLYWOOD ON EXTERIOR FACES TO BE EXTERIOR GRADE FRS ARCHITECT 35. PROVIDE PLYWOOD AND BLOCKING IN WALLS FOR ALL TOILET ROOM FIXTURES, KITCHEN ACCESSORIES AND MISC. (') p -- WALL HANGINGS SEE PLANS , z, 36 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR HANGING THE FIRE EXTINGUISHERS FIRE EXTINGUISHER LOCATIONS TO BE DETERMINED BY THE LOCAL FIRE MARSHALL C RAM ER LEVI N E & COMPANY, ARCHITECTS, P.C . � w <t 37. HANDICAPPED REQUIREMENTS: 2 O HA M P D E N DRIVE SUITE 1 Q ~ � A. THE GENERAL CONTRACTOR WILL ACQUAINT HIMSELF WITH THE ARCHITECTURAL ACCESS BOARD (AAB) FOR THE STATE OF L1/-� x _ MASSACHUSETTS AND THE (ADA) AND INSURE THAT THIS FACILITY WILL BE ACCESSIBLE. THE FOLLOWING IS A PARTIAL LIST OF CS - 1 COVER SHEET E - 1 ELECTRICAL FLOOR PLAN LIGHTING EASTON, MA. 02375 REQUIREMENTS, 1. 2, AJSLES MINIMUM 36" WI ADT E.HANDICAPPED PARKING SPACES. AND FIXTURE SCHEDULE (508) 230 - 2466 --� 3 MAX SLOPE OF 5% OR 1:20 IN ALL PARKING LOTS AND ON SIDEWALKS, ALL OTHER .AREAS WITH GREATER SLOPE 1 WILL BE CONSIDERED A RAMP. E- 2 ELECTRICAL FLOOR PLAN 4 SIDEWALKS WILL BE MINIMUM OF 4'-0" WIDE. o � 5. RAMPS TO HAVE A MAXIMUM SLOPE OF 1 12 WITH HANDRAILS AT 34" AND 19" ABOVE FLOOR ON BOTH SIDES D -- 1 DEMOLITION PLAN POWER AND SIGNAL AND TO EXTEND BEYOND THE TOP AND BOTTOM OF THE RAMP A MINIMUM OF V-6". o 6 ALL DOORS WILL HAVE A MINIMUM OF 1'-6" CLEAR ON THE LATCH (PULL) SIDE OF THE DOOR. E-3 ELECTRICAL LEGEND, SCHEDULE STRUCTURAL ENGINEER_: 8. DOOR HARDW R7. DOOR MATSDE SHALL HBEDMO NTED BETWEEN 36"TO E A MAXIMUMFAND242 HIGH.ABOVE FLOOR. w 9. DOORS TO HAZARDOUS AREAS TO HAVE KNURLED HANDLES. DETAIL AND SPECIFICATIONS HENRY J. BISHOP & SON (' 11. TOILETS: A- 1 FLOOR PLAN , NOTES, E- 4 ELECTRICAL SCHEDULES ONE- LINE A. LAVATORY TO HAVE LEVER HANDLES OR SPRING FAUCETS. AND DETAILS 05 H I LLMAN STREET B. A COAT HOOK 54" ABOVE THE FLOOR WILL BE MOUNTED ON THE BACK SIDE OF THE HANDICAPPED STALL DOOR DIAGRAM AND RISER DIAGRAM NEW B E D F 0 R D, M A, 02740 C. LOCATE THE WATER CLOSET 18" FROM THE CENTER LINE OF THE FIXTURE TO THE WALL. THE SEAT WILL BE 17" TO 19" ABOVE THE FLOOR TO THE TOP OF THE SEAT. (5 0 8) 9 9 2 - 7 3 3 8 D. PROVIDE TWO 42" LONG X 1 1/2" OUTSIDE DIAMETER PEENED GRAB BARS, 1 1/2" FROM THE WALL WITH ONE BEHIND AT 6" FROM THE WALL AND ONE ADJACENT TO AT 12" FROM THE WALL, 30" PARALLEL TO AND ABOVE THE FLOOR. A-2 REFLECTED CEILING PLAN E. LAVATORY TO BE MOUNTED 32" ABOVE THE FINISHED FLOOR TO RIM WITH KNEE SPACE OF 30" IN WIDTH AND 27" IN HEIGHT. F. INSTALL MIRROR 36" ABOVE THE FINISHED FLOOR (TO BOTTOM) AND 72" TO TOP. M - 1 MECHANICAL FLOOR PLAN H. TOILETSERS TO PAPER DISPENSERS SMOUNTED MOUNMEDfM 9M �0 CENTER ABOVE L NE ABOVEFLOOR 0 HETO ALL LOOR.OPERATING OR OISPENSINC, SLOTS. '/-�- 3 FLOOR TILE PLAN , INTERIOR A N D I. URINAL TO BE 17" A.FF. TO TOP OF LIP. EXTERIOR ELEVATION KEY PLAN M - 2 MECHANICAL ROOF PLAN MECHANICAL, PLUMBING & ELECTRICAL ENGINEER: M -3 MECHANICAL SCHEDULES BUILDING ENGINEERING RESOURCES, INC . A-- 4 INTERIOR ELEVATIONS AND DETAILS SHOVEL SHOP SQUARE M - 4 MECHANICAL SPECIFICATIONS 28 MAIN STREET, BLDG. 3A 1780 CMR) MASSACHUSETTS STATE BUILDING CODE (SIXTH EDITION) A-5 DETAILS NO. EASTON MA 02356 BUILDING CODE INFORMATION . N 1 CMR UNIFORM US E TTES ACCESS PLUMB� BOOARD 2//g/96 (508) 230 -0260 � A- 6 ROOF PLAN AND DETAI(__S BUILDING USE GROUP LENGTH OF EXIT ACCESS TRAVEL: A- 7 SCHEDULES AND DETAILS SP - 1 SPRINKLER PLAN_ (303 4) ASSEMBLY A-3 (TABLE 1006 5) 250 FEET PERMITTED WITH SPRINKLER S P} -2 SPRINKLER DETAILS _2 RESTAURANT 48 PROVIDED , LOCUS CONSTRUCTION TYPE.. Lt (TABLE 602) 2C UNPROTECTED EGRESS WIDTH PER OCCUPANT WITH SPRINKLER (TABLE 1009 2} ASSEMBLY ( WITH SPRINKLER SYSTEM) �- 1 EQ U P M E NT P LAN O Z - -2 cr DOORS, RAMPS, AND CORRIDORS P - 1 PLUMBING SANITARY PLAN �_ 6 1 / �,� � � � INTERIOR FINISH REQUIREMENTS. 108 INCHES 15S PE.6.2E NCOHES F--2 EQUIPMENT SCHEDULE _ _ TABLE 803 4) FLOOR ROOMS AND ENCLOSED TABLE 805.3 FLOOR) FINISHES SPACES 108 PROVIDED P- 2 PLUMBING WATER PLAN rp DC FF-1 CLASS III L� µ all (NOTE B) MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD Q-) C_� Lr ACTUAL OCCUPANT LOAD: (ABLE 1010.21 OCCUPANT LOAD MINIMUM NUMBER OF EXITS P-3 PLUMBING DETAILS o�cy _ n(J 500 OR LESS (TABLE 1008.0) ACTUAL NUMBER (1008.1,1) 94 OCCUPANTS 2 EXITS PROVIDED S - 1 ROOF FRAMING AND SCHEDULE S 0 10 EMPLOYEES _ i / w / _ ` m 10 SEATS PLAN AND DETAILS OLD RT. 132 DRAWN N 94 TOTAL HANDICAP PLUMBING FACILITIES: P- 4 G �.\ I =w ��'/ be PLUMBING SPECIFICATIONS J! �s �. APPR. - --� MAXIMUM FLOOR AREA PER OCCUPANT: -_--__--- . ..-.-----_-.- ---_----c (5�1 CMR) REQUIRED: YES z (30.1) REQUIRED (E' DATE (TABLE 1008.1.2) 1627 SQ. FT. _ 15 SG. FT. = 108 S N - 1 SPECIFICATIONS 0) 108 ALLOWABLE PERSONS MINIMUM PLUMBING FIXTURES FOR BUILDING OCCUPANCY: FCC / RD SCALE SITE n (248 CMR) RESTURANTS USE GROUP A-3 I %/ HYANNIS CAD FILE SN -2 SPECIFICATIONS \ , „�, R� r (TABLE 1) ! pJRP \ AIRPORT H:\PAPAGINO\HYANNIS c' n, JOB NO, SN - 3 SPECIFICATIONS _._._ _913os6 _ -- -- _ cn WATER CLOSETS LAVATORIES OTHER FIXTURES SHEET FEMALE MALE EACH SEX 1/30 1/60 11200 1 SERVICE SINK Q PER FLOOR u; 94 OCCUPANTS / 2 = 41 r c s o c 2 WATER CLOSETS (WOMEN) 1 LAVATORY ro 1 WATER CLOSET (MEN) I LAVATORY 1 URINAL 28 8 Cl 1 SERVICE SINK (KITCHEN) .... - _ jo 7.1 NO. REVISIONS j GATE Lip GENERAL z !, z 2\ GENERAL _ 1/19/9 4 ---- ' -- --- ----- Cc0 � m 3 j 1= z EXISTING RESTROOM ALL wLT WALLS TO RECEIVE 8" x 8" \ Z z cn Z / w 11 . MEMBRANE BETWEEN FLOOR AND WALL j w Jt{ '� ,I —P,NSUL PANEL ELECTRIC PANELS 00A._. c� \ ►--+ BACK KITCHEN ! ;,�► I 4 W ni 17'-9 1 8" 14'-3 1 4" 9'---11 1 2" v 23'-2 1 2" 17'-9 1 2" r' '- ,. A-7 E, a Ij LIGHT PANELS _. COQK,I INS . 1107 p , 1 �' 1.0 NOTE: G.C. TO VERIFY OVEN "00 A-5 SIZE AND CLEARANCES PRIOR - ! cJ To INSTALLING PARTITIONS i '�� oo \ I DELIVERY FREE7ER WALK-IN C'UOLER ! I �* PIZZA v A-7 112 111 110 i � �� E 108 2� 2 i l FIRE �1 A-7 _ PROTECTION _ -- - -- -- z PANEL w _ F2 SERVICE 2 - _-= z i i j - c? �g 106 ! A -5 d. p_ . _ --- _ _ a O O � - v ____ O DINING {� O ' '. ° . z ----- - ------.__ _. _ r z ,_ VESTIBULE �' I "�� ' EXISTING COLUMN I `• T . —__ EXISTING COLUMN 101- I L'- / _100 I �LL_ 5 v O ��� I CORRIDOR ZB L cJ is ,� p o 4UJI 0 ._ � � L� � t 10 i 4 __ _ I A-51 --_ _ ---_--- _ .._... _ , _ �- �- EXISTING COLUMN ���, C. : y 9 of WAITING tO � -- — ----- I ( ao 1 2 C7 MEN r WOMEN 04 i F CV 2'-0 7/8 1�J5 �\ I I - 9'-6 1/4 j y -6 i3 13'-3 3 4" 9'-0 1 8" I 10' , 1 7/8" I 4'-7 1 2" t i * -'�`" / 5'-11 / / 4'-6' / 12'- 0' 11 -6' — _ a - - - -- - -- O z o / \ o, f - I �, Z N J Y l % x r`i I ' I A-5 4 !f I co L7 M V) 'Y l_J (I i�1� c� cfl r� I �- Z LIDN- z o q `" �J ��� ,� I .j Li Q ~ z COMMON HA (.- -� I I 0 L L -- - _ - —- - I /^Q i / - ALL 'WLI WALLS TO RECEIVE 8" x d" / lO MEMBRANE BETWEEN FLOOR AND WAIL CI- \` Ir A-2 _z O O O _FIRST FLOOR PLAN d EXISTING RESTROOM SCALE: 1/4" = l'-O" Z 115 I f I F- 0 LE(-,END z EXISTING CONSTRUC-i ION TO REMAIN L:l 4 1/8" 4 7/8" 7 1/4 4 7/8" 5 1/4" f l= =-: NEW PARTITION: REFER TO WALL TYPES ---� — -� — T � FOR CONSTRUCTION n r V I 1 LAYER OF 5 8" ( + } " f 1 , ►M AR LAYER OF 58 1 YP UM OF 8 O Y R nF .� 1 n I ; 1 LAYER OF 5 8" GYPSUM SLAYER B F 5 8" iE--- 1 LAYER OF 5/8" GYPSUM BOARD TO Y I / _S I G PSL 8 : [1 0 I G S BU p 1 lA E, /8 1 LAYERS OF 5/8" / {� - 6 ABOVE FINISHED I 1 LAYER _F 5/8 I OAR TO GYPSUM BOARD TO 0 Q �' CEILING 6" ABOVE FINISHED 6" ABOVE FINISHED GYPSUM BOARD TOI GYPSUM F30AkD TO GYPSUM BOARD TO DECK A BOARD TO 6" ABOVE FINISHED 6" ABOVE FINISHED L�ENEKAL NOTES CEILING CEILING DECK A80VE------�h �<\ DECK ABOVE DECK ABOVE DECK ABOVE CEILING CEILING � 0 a I Ld 3 5/8" METAL STUDS I —� AT 16" O/C I 3 5/8" METAL STUDS 3 1/2" BATT. INSULATION 1 . CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF `' A 1 6 ' O C TO (ECK. ABOVE. �' _ S 1/2" METAL FURRING ALL DIMENSIONS AT THE SITE. THE PURPOSE OF THIS [� T b / � 3 5/8" METAL STUDS " AT 6" 0/C CHANNELS AT 16 O/C DRAWING IS TO DEPICT GRAPHICALLY ONLY THE. GENERAL NATURE OF WORK. L6" METAL STUDS .,1 co 1 i I AT 16' O/C 3 1/'2" GATT. INSULATION I 2. ALL DIMENSIONS ARE TAKEN FROM FACE OF EXISTING i I TO DECK ABOVE. OVEN $IpE CONSTRUCTION TO CENTER OF NEW STUD WALLS, UNLESS v I f OTHERWISE NOTED. DRAWN bc, tm �T J ! 3 PROVIDE CEMENT BOARD TO 1 )" ABOVE FINISHED FLOOR -- '" 5/8" CEMENT BOARD ----- 5/8" CEMENT BOARD ) 5/8" CEMENT BOARD 4 5/8' CEMENT BOARD 3 5/E3;' METAL. STUDS ON ALL WALLS RECEIVED TILE FINISH. APPR 18 A.F.F. j 18' A.F•F 18 A.F.F. I "�, 1 18 A.F.F. AT 16 O/C `i 4 PROVIDE MOISTURE RESISTANT GYPSUM BOARD ON ALL DATE _ I WALLS RECIEVING TILE FINISH. 1U/9/98_.______..,_... 4j 5/8" CEMENT CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF EXTENT SCALE. „ 5/8 CEMENT BOARD _ _ 1 J4' _= t_'-U TO 18" A.F.F. OF WORK REGUARDING EXISTING CONDITIONS. CAD FILE - --- 6. FOR FLOOR AND WALL FINISHES SEE ROOM FINISH AREA OF RENOVATION a ! SCHEDULE ON DRAWING A-7. H:\PAPAGINO\HYANNIS _- '/2_� ?. COORDINATE ALL UNDERGROUND PLUMBWG WITH MECHANICAL JOB NO. 98066 DRAWING TRENCH, REMOVE, PATCH AND REPAIR EXISTING SHEET CONCRETE SLAB AS REQUIRED, 8 PROVIDE FIRE RETARDANT WOOD BLOCKING IN ALL WALLS AS REQUIRED TO ACCOMMODATE ACCESSORIES, PLUMBING FIXTURES, MILLWORK, ETC. COORDINATE WITH ALL TRADES. 114 I/ = ter C� >D — >E - 9. CONTRACTOR IS RESPONSIBLE FOR PROVIDING NEW CONCRETESLAB WHERE REQUIRED. VERIFY EXTENT OF WORK: AT THE SITE. WALL TYPES _.- KEY PLAN Lo SCALE: NOT TO SCALE a ro c� 2 Nib. REVISIONS I DATE GENERAL - I/-/9E - -_ - U z --�-= z J O I 0 ~s — —1--------—— -- _ Z Z w x - w i. w A� ��� 5 a 4 3 & :wF —.— _44r— -- --- -- -- -- -- T—: --- -- �i CO 7"i , - -- - - - - I I ©o 1 I ' (1 ,9 z0 �, 22 4 -- - __ ( - , < Y i I I I I I 27 U o 0 0 A.- Ld L �" m a m W 3 ! - Li M W ° w . CL 13 44 IL (253 o CL a —�) - EXISTING COLUMN - - - - - - - - - -a I i +— 7 15v2o 21 { I 25 10 If I ! , cn -- - -. -- - - - -- - - -- -- - - - - - _ - - - -- - PROFILE OF EXISTING ! I - - - _ - - . -- - -- - -- - _. _1 ROOF ABOVE. Z a' fLi-- < � ,8 Q \J z Z I _ x w Oo I I J c 3 Ii ! I 17 FIRST FLOOR PLAN Z Z -- r SCALE: 1/4" I I I LI � I � a_ z DEMOLITION TAGS (\`1) EXISTING PARTITION TO REMAIN 19 REMOVE EXISTING CEILING PILE AND GRID EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN 20 REMOVE EXISTING LIGHTING, EMERGENCY LIGHTS, EXIT SIGNS t �J FXISTING DOOR AND FRAME TO REMAIN 21 REMOVE EXISTING 1NIRING AND CONDUIT BACK TC. PLAN. DEMOLITION NOTES - -- - ---- —`---- `� 40 REMOVE EXISTING DOOR AND FRAME 22 REMOVE EXISTING CFfI_iNG REGISTERS AND DUCT WORK W 1 ASBESTOS ABATEMENT - REMOVAL T{PICAL 5 O EXISTING WINDOWS TO REMAIN (23 REMOVE EXISTING GLASS AND FRAMES IN THEIR ENTIRELY � Q THE ARCHITECT HEREBY SIATES, AND THE CONTRACTOR AND THE OWNER ACKNOWLEDGES, THAT THE l°J EXISTING STRUCTURAL STEEL COLUMN TO REMAIN PATCH FLOUR, WALLS, CEILING AND PREPARE TO RECEIVE. NEW FINISH ' ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, AND IS UNABLE TO REASONABLY CIO NOT USED OBTAIN SUCH INSURANCE FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR FAILURE TO REMOVE EXISTING STUD AND GYPSUM BOARD PARTITION. PATCH AND REPAIR FLOOR, WALLS, PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO THE PREPARATION OF REPORTS, CEILING, AND PREPARE TO RECEIVE NEW FINISH. DESIGNS, DRAWINGS AND SPECIFICATIONS, RFLATf'I? TO THE INVESTIGATION, DETECTION, ABATEMENT, t") SAW CUT AND TRENCH EXISTING CONCRETE SLAB AS REQUIRED REPLACEMENT OR REMOVAL OF PRODUCTS, MATERIALS, OR PROCESSES CONTAINING ASBESTOS. CG EXISTING 4" TO INSTALL NEW UNDERGROUND PLUMBING AND UTILITIES. DRAWN PVC PLUMBING MODIFY AS REQUIRED FOR NEW CONSTRUCTION. ACCORDINGLY, THE CONTRACTOR AND THE OWNER HEREBY AGREES TO BRING NO CLAIM FOR PATCH, REPAIR AND, REPLACE CONCRETE AND BLENA TO MATCH EXISTING. REMOVED EXISTING CARPET AND PREPARE FLOOR TO RECEIVE NEW FLOOR FINISH 26 REMOVE EXISTING DOUR AND FRAME AND PREPARE OPENINGr' NEGLIGENCE, BREACH OF CONTRACT. INDEMNITY OR OTHERWISE AGAINST THE ARCHITECTS, HIS r PRINCIPALS, EMPLOYEES, AGENTS AND/OR CONSULTANTS IF SUCH CLAIM IN ANY WAY WOULD INVOLVE TO RECEIVE NEW WINDOW C,t�4Z1NGTHE ARCHITECT'S SERVICES FOR THE INVESTIGATION OF OR REMEDIAL WORK RELATED TO ASBESTOS IN ! [DATE P E �0 REMOVED EXISTING RAISED FLOOR CONSTRUCTION. (27) `RFMnVE EXISTING DOOR AND FRAME AND RFI OCATE �1 ` � THE PROJECT. "-"-----'"- THE CONTRACTOR FURTHER ACINOWLEDGES AND AGREES TU DEFEND, INDEMN WY AND HOLD THE (1 1 EXISTING WATER HEATER TO BE REMOVED. AS SHOWN ON A-1 0 9 98 OWNER AND THE ARCHITECT AND HIS PRINCIPALS, EMPLOYEES, AGENTS AND CONSULTANTS HARMLESS SCALE 1/4 s 1,_0„ FROM ANY SUrH ASBESTOS-RELATED ^LAIMS THAT MAY BE BROUGHT BY THIRD PARTIES AS A RESULT 12 REMOVE EXISTING VANITY, SINK AND STUB & CAP PLUMBING BELOW SLAB -- OF THE SERVICES PROVIDED BY THE ARCHITECT PURSUANT TO THE OWNER - ARCHITECT AGREEMENT CAD FILE { IF, DURING THE CONSTRUCTION OF THIS PROJECT, WORK INVOLVING FRIABLE ASBESTOS IS SUSPECTED �3 REMOVE EXISTING SHELVING. --AREA OF H pAPAGINO\HYAPINIS OR ENCOUNTERED, THE OWNER OR THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY AREA -�- .AND THE CONTRACTOR, WITH HIS OWN FORCES, OR BY SEPARATE CONTRACT SHALL BE RESPONSIBLE 14 REMOVE FXISTING CASH STAND - lOB NQ--98�sfi---- -_-- y FOR COMPLETE INVESTIGATION, REMOVAL AND DISPOSITION OF THE FRIABLE ASBESTOS HAZARD IN SHEET c r ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS, 15 REMOVE EXISTING VCT AND PREPARE EXISTING FLUOR TO RECEIVE NEW FINISH, ALL EXISTING CONSTRUCTION TO REMAIN EXCEPT AS TAGGED AND NOTED BELOW. 6� REMOVE EXISTING WINDOW WALL PATCH. 17 EXISTING SPRINKLER SERVICE. ? 18 EXISTING ELECTRIC PANEL. J KEY PLAN �,Aj NCI, REVISIONS ]TE GENERAL GENERAL m + OD v z PATCH AND REPAIR z c jx EXISTING GYPSUM cn X CEILING AND PAINT L w - I ; I WW--. ____ _- .___ .---___ •' ' _.__ ; __ __ __._ .. 1 may•' r III t 1 I c 10 W < r , { 1 `A A-S lk I - I I , -7-4 -T- ,— BUt_kHEA> C� 7 ; 01 Wx 0" a F EXISTI G 1 'x4"I ---I---" --- ^._.-_- � - j _.. _ .L_._�-_ - _ .__ _ _-_ _._-_-- _-.- _-._.... __-.. y 4 V! G I ' FLUORESCENT -- b- , UF V I i } _ ! 0 i � i z - I HOOD -- I j I I IaC , : ❑ I I � i � �... .. I � I I i� i I ❑ I I ❑ i � C1_ -_.Q.� � ►-_ Y o a -- -_- -- -- - - - ----- -- -- --- ---- I r� - - -a- ----- r-?--- - ____- . - • a L cam_ ---- _- - — --- - - - O cr— s W 3 - cy I w o0 I i I - �+- -- -- -- o ! ❑ j i }-- w --- — - -- -- - - t ! Li F- n_ - I q � _ _ o e - --t---- r-. _ -- r. cc o � - - r( �j .._. ._.-- -- --- -- - -- �_--- - - - --- -- - - - -- ------ -- - -_ -1-W-- -� EXISTING COLUMN ^ 110 - , I � -jo t 1 10 0 C2. 8 -9 - ® ❑ I I li C II I I ❑ I I i I i I I r I A-- IF, -4 � I. Ii _ r i 4 ® 0 I I ( i i ' ' -�-- — ---- --to _—t - --- I J I 1 -� ! , , � ► I , , Q _ _ z _ I _ _ _ - - , I _ - --- ' r ui CL W Q z a_ Q _ o A--2 m 0 z 0 1 I j P Z 0 C �^1 I REFLECTED CEILING PLAN 1 SCALE' 1/4' _ I - I I II EXISTING ROOF r --- -- -` ----A---- - - W CEILING LEGEND (SEE ELECTRICAL DRAWING)) T EXISTING BAR JOISTS ��, ' i{ SUSPENDED INCANDESCENT PENDANT LIGHT M _J 2' x 4' RECESSED FLUORESCENT LIGHT FIXTURE t FIXTURE AT 5'-6" A.F.F. W -EXISTING BEAM �� HVAC SUPPLY DIFFUSER, I' C-----i 1' x 4' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ❑ SEE MECH DRAWINGS BULKHEAD BRACING---'- \ cp / I -- -� 1' x 8' VAPOR TIGHT FLUORESCENT LIGHT FIXTURELA- W �.< / HVAC' EXHAUST OR RETURN AIR GRILLE C l.Ll BULKHEAD ® 7 -0" A.F F. �\ I �� FLUORESCENT STRIP OR UNDER 11 CABINET FIXTURE E HOOD if EMERGENCY LIGHT, 2 HEAD, WALL MOUNTED 0 '7 8' TRACK LIGHT FIXTURE WITH 4 INCANDESCENT `" o HEADS PER TRACK EMERGENCY LIGHT, SINGLE HEAD, WALL MTD. DRAWN be t l RECESSED INCANDESCENT DOWNLIGHT 00 `D EXISTING EMERGENCY LIGHT, 2 HEAD, CEILING MOUNTED APPR. � WAITING � �-- r - I SERVICE COOK LINE CEILING MOUNTED ILLUMINATED EXIT SIGN _ AREA OF DA TIE 10/9/98 -- 10'' ! � C� � i 107 --- --- �� CEILING TYPE, SEE FINISH SCHEDULES �_-_ EXISTING 1'x4' SURFACE MOUNTED RENOVATION SCALE 1/4" = 1'-0" I i FLUORESCENT LIGHT FIXTURE _ cr GAD FILE. s� H:\ PAPAGINOS HYANNtS CI $'-0� CEILING MARKER SPRINKLER HEAD � --_-------___�. CEILING HEIGHT, ABOVE FINISHED FLOOR Joe No. � L 98066 -- - - -- ---- -- - SHEET rn _ (1 SECTION A��2) SCALE: 1/4 = 1'-0" v c a KEY PLAN N0. REVISIONS I DATE OB A GENERAL _z ' C7 z — J =.1 Y m o Y m C Z Z cn z ALL WET WALLS TO RECEIVE 8" x 8' - � - �x MEMBRANE BETWEEN FLOOR AND WALL --7 LJ x LAJ Ar Al C:�:D -C7 -- -- EXISTI G RESTROOM �` - ---- -- --�--- 25 - �"' 113 BACK KITCHEN F-2 COOK LINE -; _ _ 1 _ 4, a r-•t _ TF2 F 3 4, �� 1 - T— I DEIF -- _ 4 ❑❑f(��(� 1 L_.1LJ I 14X48 f .�! m J X I I v - 24x6 n -EXISTING CURB DELIVERY �----- --- --_ ---- � ---- 2 ( PIZZA 11 FREEZER � F-2 � �O8 _ � i I ..... . . j 44 IFill FREEZER L] - _ I 41, _ 24x6 24x3 4r.. 6. 4x4 �. - --1 SERVICE �8 w^--�^.� _ �_- _ —_— 1 _ � - - - ��t 1 66 I °' w 3 .. �: - --- _ F r DINING d /,/ESTIBULE O 0 >1 _`-_ -- (V �� uj HIM O p74 w —i 30 COf�R1pQF L ' 100 p - �f-1 , _ a - — _ / - 1 q A r . iii I r r' WAITINGCL ' ' ry __ p w..� , c7 "� F-2 I r„ WOMEN 3 RECESSED ENTRANCE MAT ~, 105 ' ! ,I - , BY "PAWLING CORP.", --- --- -- --- EXISTING COLUMN r r!] F_ - -r-- ---- - --- --- -- 3/8" DURA TILE PAVER �► ^1 TIL L7,] :' ------ —- --- - — E PROVIDE - . '----)' f \'• � TRANSITION STRIPS AS I + MEN �00 1. t � - o REQUIRED BY r� r MANUFACTURER. _ r , i -- --- _ - N - - _ --PROFILE OF EXISTING Lo tv _ 3 3 I � ROOF ABOVE. O 1r— CD ' 1 3 �,-.J --LL 2 �UIvtMUN HALL O C-� Q � z 114 � ,- I p W x -= ALL WET WALLS TO RECEIVE 8" x 8"ell MEMBRANE BETWEEN FLOOR AND WALL o 0 0 z _ _.,� FLOOR TILE PLAN_ AND _INTERIOR KEY PLAN j I SCALE: 1/4" 1'_0�� _-_-. M � c , `I z O a _ f-- z v� L x w C !) EXISTING RESTROOM LLJ 115 ry C1 1_j -------- O 0 i EXISTING BUILDING 34'-10 3/4" EXISTING BUILDING NO WORK - LIMIT OF WORK NO WORK Q Q LJ EXISTING 1 PAPA GINO'S SIGNAGE ALUMINUM DRIP CAP ----� BY OTHERS d-- W x L A-3 PROVIDE WIRED JUNCTION � G� cn BOX IN EXISTING FASCIA NEW 1 " INSULATING GLASS �` � 0 I FOR SIGNAGE I rn O IN ALUMINUM FRAMES TO Ln EXISTING s �_ MATCH EXISTING. �n E.I.F.S. -� - , a: �- - �- EXTERIOR GYPSUM cf, 3 5/8 MEIAL STUDS 16" O.C. ---� KICKERS ® BOARD, SOFFIT ® W Q' U C. I �- 0 �--- Q LL1 --- EXISTING E.I.F.S. EXISTINGco VERTICAL WOOD SIDING cn LA_ CL Li C) SUSPENDED ACOUSTIC I o CEILING TILE Q EXISTING E.I.F.S. --- I DRAWN tm APPR, N � I z o + O DATE 1 Q EXISTING F - EXISTING ANODIZED A -IJMINUM ANODIZED ALUMINUM I AREA OF SCALE 1/4" _ 1'-0" CLASS STORE FRONT GLASS STORE FRONT -- RENOVATION `"- 3 CAD FILE n -H_\PAPAGIN0\HYANNIS 4 EXISTING � �- -- � JOB NO. 98065 o ' - CONCRETE WALK WA r - _- coo SHEET 1 SECTION THRU WALKWAY EXISTING STORE FRONT TO REMAIN -- -- ` _ NEW STORE EXISTING STORE FRONT FRONT TO REMAIN A-J/ SCALE: 1/4" . .. p `-' A FRONT ELEVATION � '� co m _ - c A- SCALE: 1/4' 1 '-0" KEY PLAN -- NO. REVISIONS GATE WOOD CROWN MOLDING -- 1 " INSULATED GLASS --- WOOD CROWN MOLDING ( 3 �— IN ALUMINUM FRAME EXISTING STORE NEW STORE EXISTING STORE FRONT TO REMAIN 3 STAIN p, -GENERAL !71 /9 A---5 � STAIN �i) �---- - -- - -----_____ -- —_ _� —.--------- A-5 Q -5 � I ��- _i. To MATCH EXISTING — (FRONT TO REMAIN FRONT I GENERAL f i i I i W2 ► f I I I 6 W2 �-- 1 x4 WOOD TRIM WITH STOOL CAP li jl 4 E -- - - --.. STAI N P, > --� 2x4 WOOD TRIM 2x4 WOOD TRIM r--� I I ( t 1 x4 WOOD T IM / WITH STOOL CA F i WITH STOOL CAP 9 A WITH STOOL !CAP STAIN P1 --� STAIN Pt I A-7 ii j / I Ii STAIN pt / n.. II , ���t W i c { I Wl I t s I W1 ) I P5 � I. I�i , z {! � i 1I i 1 ( i I : I I I I I I ! i _ - -- ----- ------ _ w ELEVATION 1 NEW " -INSULATING GLASS ELEVATION ELEVATION #7 _ _ ELEVATION #2 ELEVATION #3 IN ALUM►NUM FRAMES To ELEVATION #4 2- WOOD _TRIM _ _ � a b SCALE 1/4" - 1'-0" 3 = 1'-0" SCALE 1 4" - 1' -0" MATCH EXISTING SCALE 1 /4' -� " WITH STOOL CAP SCALE: 1 "4" - 1'-0" u.l 1 4" = 1'-0" SCALE: 1/4' / - __ q-7 - STAIN / - WOOD CROWN MOLDING / (x::5 STAIN p, �� STAIN p .� WOOD CROWN MOLDING �. W o t^ F --- STAIN P' ----- -- - - i W2 ---- -- - --- -- ------ -- - *{;A o 1 x4 'WOOD TRIM I 1 1 x4 WO D TRIMtr � WITH STOOL CAP o ! 1 x4 WOOD TRIM / ,1 , WITH STOOL CAP STAIN I I 1� ! , :r I WITH STOOL CAP I STAIN a ow STAIN _ I. { ( I I f � 1 i I I i I i !I i� I � 1 I I I I I I f : ! 1 I t . I t 1 � I I I i I � F 1 -- � ------- ----( F1 , ssea.-YS woo� CROWN MOLGiNG s ELE ATION �\ V V ELEVATIO_ N _ 1 0 �--STAIN _ SCALE 1/4" = t -o" 2 STAIN CROWN MOLDING Z`�\ SCALE: 1 4" - 1 0 P'� j q_5 ,- ELEVATION #8 ELEVATION 9 / . ---___ . __ .._---- -- ____-__---_- ----------- ---- ------ -------------.__---_________ ,,_1 /4 - 1 o SCALE- 4 - 1 -o EXISTING "w2 i &'=.r COLUMN LIGHT BOX 6Y MILLWORK CONTRACTOR, 1/4" Ct_EAR , INCASED PROVI E WIRED JUNCTION t30X cTEMPERED GLASS -- 2 -IN WALL --__ _-- _ _ _ - .__ _ _ ----- - -.._..-- ______ --------- .�Xl�TIN_G._._ � �� 4 CLEAR TEMPERED c�IA�s SEE MILLWORK �� SEE MILLWORK j '2\ � COLUMN I / SHOP DRAWINGS A 5 SHOP DRAWINGS �A_5 INCASED i IN WALL— - - ,I SEE MILLWORK �- I I �� I' - t x4 WOOD TRIM v � WITH STOOL CAP I SHOP DRAWINGS I a STAIN I w, w, ; w1 l ` I II I , I i i,l 1 i i --� Q I 'i: � I li i i I ! I� I 1 , I ( I I 1• � P 1: 1 I 1 I T tl I I' I P i P 1 i I P1 P1� P1 I , I P �1 I I i Ti �i � Ii ! 1 I , r :ii I, l ; I j{ I i „ II IN ► � : I I i Ii I � I: 1 .: ► f I , . I i 1 ',I , : I i � , I O 1 � � I• I I I I l _ Lw� r .Llll,�.. , I L � ,1! I 11 � ,, I. I , I I I I , i f . - - - F 1 _ .- - F � P i P I ) - - P 1� v ,/4" CLEAR TEMPERED GLASS /`, ELEVATION _k1 1 ELEVATION ## 1 1 A-- SEE MILLWORK ELEVATION__# 12 ELEVATION 13 ELEVATION 14 V I ELEVATION 16 J �— z ;� - -- ,SHOP DRAWINGS -- — ---- --- -- ELE AT i O N # 15 SCALE 1/4'; -- 0„ SCALE: 1%4" _ 1 - U" i _ `;c.Ai._t 1 ,4„ _ 1 '-0" _ _. - Q SCALE. 1 4" - 1 '-0" SCALE 1/4" - 1'-0" SCALE: 1/4" V-0 Z -- SEE MILLWORK / Q t— >" �. SHOP DRAWING.., — SEE MILLWORK --,� A � - `�-' -- SEE MILLWORK -- -- r SHOP DRAWINGS RK SEE MILLWORK ', SHOP SEE ILLWO DRAWINGS -�� _� .. -_ _ __ —__ `' • SHOP DRAWINGS SHOP DRAW! - - -_—-- --_-- .-. - - - NGS — - N ?l !"'� I i �I , {� ! fi 1' w, w) I , j +' wt _ I I .II i' I I � I I � I I � I I � I { I I , I I ! I I I I I I o� I t I , P y-I . I I , P I P1 P1 1 P 1 I P1 i I I : , I I / I I 1 i II I ► � I I i 1 1 ! I 1 t 1 . � I I � I f a I I _ i i i I : I . i I 1 � � , I II I I ! i I I I � I 1 i , I �I i I II I I .I - I I - - P-1 -- Pi .- P 1� -----.._ -- - tP--- - PP1 - --- P 1� P 1 ELEVATION 17 ELEVATION 19 ELEVATION 20 ELEVATION ff2_1 �- - 1x6 WOOD ELEVATION 22 ELEVATION 2 3 ELEVATION # 24 ---� ELEVATION .# 18 ---�---- -"- -----�--- S�,ALE: 1 / 4" � t '---0' BASE STAIN � �-` �--- SCALE: 1;/4" = 1'--0" — SCALE: 1/4 = V-0" FPI E. 1 ,`4" ? -�! SCALE: 1/4" = 1 '-0" SCALE: 1/4" = l'--O" SCALE: 1/4" = V-0" SCALE: 1/4" = 1 '--0' ` WOOD CROWN MOLDING - STAINLESS STEEL WOOD CROWN MOLDING �a —_ _ -'' - — _-- _ 2 STAIN pi 1 _ EXHAUST HOOD STAIN P --1-- _ � MENU BOARD � w' W4 1M6� �- - - i 4 1 a : J _ I (�A 00 I r i1 ' , ' ; � 7 y � � ' i i- N P _ - A 5 - t — - — _ • I - - 1 I --. - _max__ --a_-.— __ ' ; W4 i ,I `j l � k W4 i _: -, 11 . .._ _ -T. F, rr; __�_�-- _ _ _ , rs-- _ F2 W _ ,._ L� I _t�_ 1- � 1�I_: Lt_T�?` L C�J1 -�� � I SEL MILLWORK SEE MILLWORK SEE MILLWORK SEE. MILLWORK - ELEVATION #25 ELEVATION .�'26 SHOP VRAWINGS SHOP DRAWINGS ELEVATION 27 SHOP DRAWINGS ELEVATION #28 SHOP DRAWINGS ELEVATION #29 (1' — SCALE: 1/4" = 1'-0" SCALE: 1/4" = V-0" /Y SCALE: 1 /4" _= , '-0" SCALE: 1/4" - 1 '-0" SCALE: 1/4" = 1'-0" 0 E 3'-1 1/2" 5'_4 3/8" 5'-4 3,s" TOILET EQUIPMENT SCHEDULE c' w 1 x4 WOOD TRIM > — 1 x4 WOOD TRIM �= 4 L' 1 x4 WOOD TRIM ITEM - � W9 STAIN P, ^yJ W9STAIN P, DESCRIPTION MANUF. &. # REMARKS �-- a STAIN p t G, „ � C� __J C PK NO. MOUNTING . _ A. F �) 3 -8" 6' '�` 1 0 3'-b" (� GRAB BARS 1 -1/2" DIA. STAINLESS STEEL BOBRICK B-5806x42 2'-10" A.F.F. PEENED GRIP & POLISHED ENDS --! _ ----- - - --------- -- --- fl -- - - _ - q A _ TOILET PAPER DISPENSER COY OWNER 24" A.F.F. TO CENTER LINES INSTALLED BY G.C. m w� I W7 g p ao I B o �. o W7 W7 F2 ' ` _______ —__--. — ' -- SEE NOTE A INSTALLED BY G.C. ---- Al L fi c PAPER TOWEL DISPENSER BY OWNER _ -- iii��� _ N _ 4►� -1 I __ _ SANITARY NAPKIN RECEPTACLE ---' 4" A.F.F. TO CENTER T_�T? j _7.? T T r_., F2 r r-T- , ,-r C - ,- F2 r-,-- F2 T T T r T T-1- > p ' _ ---- BOBRICh _ --- - _LINES OF RECTICLES _------- --- -- ----._.___.— 1 I T , r-n-. n T �-T- r 1-1- _I-1_T�__ �_._ _ _ Y._ INSULATE ALL PIPE -J OE SOAP DISPENSER — -- BY OWNER SEE NOTE A INSTALLED BY G.C. _---_ DRAWN ! BELOW SINK. — —� try), PO, amp . ELEVATION ##30 _LEVAT10N _#_31 ELEVATION #32 ELEVATION #33 0 - 36 A.F.F. TO BOTTOM EDGE "ALE: 1 4 " = 1 '--0" SCALE 4., , _0' � L = 1 / - . y" -_ _ -_ _. --_ _ -_ -- -- - --- _ . F MI BOBRlCK E3-290 2436 OF REFLECTING SURFACE APPR SCA E 1 %4" i ' -°� �t:Ai_c i 4" 1 ' -C — U COAT HOOK (HANDICAPPED) BOBRICK B-272 54" A.F.F. DOOR MOUNTED DATE r -- --- -- — - --- - - 5'-4 3 8" 2 -1 1 1/8 -1-7" TO 19 MAX. A.F F. 18 OFF NEAREST WALL TO 10/9/98 / H WATER CLOSET � .. _- - -- - - - TO W.C. SEAT—_—_--.__---------- _ CENTER OF WATER CLOSET SCALE ----,/4,. _.;-� { <t - 29 MIN. A.F.F. KNEE C T 1 x4 WOOD TRIM 1 x4 WOOD TRIM �l 1 x4 WOOD TRIM t SINK 33" MAX. A.F.F. CAD FILE wg c ws K W9 wsCE _ MUST EXTEND MIN. L ROMNWAL. U ` STAIN P1 STAIN P1 STAIN ( F ) I o 4 MAX. A F. H`�PAPAGINO\NYANNlS — - - URINAL �2 17 ' MAX. A.F.F. TO RIM OF URINAL -- __. 3'= 3'-6" 11� -- _ LUSH CQNTRO�S_ .►oe No. 9sos� _ ,___-_-- -� �� ---_-__--- _.. __ ----- _- -.-_ - -__ _ .-- _.-- - _ _ _ _. __ _ K� ELECTRIC HANG DRYER Br OWNER 42" MAX A.F.F. INSTALLED BY G C \ _- m '� (A 4-1 r, SHEET w7 ( W7 --_t, INFANT CHANGING iABLE -T RUBBERMAiD - --- -'- __- -- ------ - �w� 1 co I L_i 'T 1 r F Z I 1 i : ,-_� r�. F2 (B -- i, -1- -T-r-r -- r- -r?�-? ,-I---I--L-T-T-?--r 7-1--�-T--T- T--,, -- T--T-T--r-r-r-r-r� ,- -- Z 1 i -' ?- - -�� �y� N F2 NOTE A: OPERATING CONTROLS OF ALL PAPER TOWEL DISPENSERS, SANITARY NAPKIN A - 4 v, DISPENSERS AND MULTI PURPOSE UNITS TO BE 42" A F.F. ELEVATION #334 ELEVATION #35 ELEVATION 36 ELEVATION #37 - INSULATE ALL PIPES r — - - - BELOW SINK. NOTE B: G.C. TO FIELD VERIFY ALL SIZES SCALE l ;4" _- � ' -0" S�..ALf ;4" _ ? J.. SCALE: 1 /4" = 1'-0" SCALE: 1/4" = t'-0" NOTE C: PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL MOUNTED FIXTURES AND ACCESSORIES �° NOTE D C-.C, TO VERIFt ALL HANDICAPPED MOUNTiNG HEIGHTS WITH LATEST A.D.A. AND LOCAL HANDICAPPED CODES. -- ACOUSTICAL CEILING TILE AS No. REVISIONS DAlE PER SCHEDULE. -" 1 x WOOD CAP. ---_ %`-\ GENEP,AL 11/-/9 - 10'-0" GENE AL 1 /19/98 2x WOOD BLOCKING. TI A.F.F. 1 x WOOD TRIM. ; "BROSCO" #8006 CROWN1 1 2" PIPE RAIL BY LAWRENCE 00MOULDING WITH WOOD / 1/4' TEMP. GLASS SET BLOCKING HEADER. METAL PRODUCT_, INC.' COLORIFIC IN 1 " WOOD STOPS. -- GREEN WITH POLISHED BRASS j END, CENTER AND ANCHOR PLATE CDPIECES. ! 1 x WOOD CAP c 3' T A.F .F � r I --- --- i 1 x4 WOOD TRIM. � a L I 1x WOOD CAP. i 1x WOOD STOOL CAP w PROVIDE TREADED ROD AT __L EACH END OF ALL HALF WALLS. - -� . Ci. A.F.F. f A.F.F. 1 x4 WOOD T-RIM. L lx4 WOOD TRIM 4 NOT USED W T MARLITE DADO / PANELING ` 2"x6" CONTINUOUS WALL I / SILICONE SEALANT (BY G.C.) I SILICONE SEALANT (BY G.C.) SCALE,. I BLOCKING AT ALL BOOTHcq I UAL�\ I � I-ABLE_ TOP (c;.C.) TABLES (BY G.C.) �-- TABLE TOP (G.C.) 5/8" GYPSUM BOARD. - --- J. - MARLITE DADO / PANELING `I 2"x6" CONTINUOUS WALL BLOCKING AT ALL BOOTH 5/8" METAL 1 STUD AT 5/8" FIRECODE GYPSUM----,--- TABLES (BY G.C ) -- 6" O.C. -- ( BOARD -- 2"x2"xt/4" STEEL WALL ANGLE 2" A �r x2"xt/4" STEEL WALL ANGLE ANGLE TO BE 4" LESS THAN w i ANGLE 0 BE 4" LESS THAN w THE WIDTH OF THE TABLE TOP z I THE WIDTH OF THE TABLE TOP z CENTER ANGLE ON TABLE, o CENTER ANGLE ON TABLE, o kJr� PAINT ANGLE TO MATCH. PAINT ANGLE TO MATCH. I F- ,t 3 5/8" METAL STUD AT °"16 O.C. �' TABLE BASE c / . . 1 � TABLE BASE \GC ) tDCA -. -"MARLITE" DADO / PANELING 1 ,1 s n 1x6 WOOD BASE, BOTH SIDES ii w •J� � a _ BOTH SIDES I = _ EXISTING GYPSUM BOARD. aiF I 1 w Ill r � CORE DRILL EXISTING CONC. > > ti SLAB AS RFOUIRED TO INSTALL 1x6 WOOD BASE I NEW THREADED ROD. , I x6 WOOD BASE BOTH SIDES ------ ----- I 1E— 1 HALF WALL DETAIL NOT USED 2 HALF WALL DETAILWITH GLASS) 3 WAINSCOT WALL DETAIL SALE: 1 1/� - SCALE. (A-5, A-5 -,(-At 1 1 /7' = t'-0" SCALE: 1 1 = 1'-0" SEE MILLWORK SHOP DRAWINGS �� A--S /� -"� SEE MILLWORK SHOP DRAWINGS. z N (_n /. W-4 CL Lil Q (:F�-�2 -- - - - 3 5/8" METAL STUDS ® 16" O.C. t F- 1 W-5 A.F.F. - A F.F. � FASTEN TO ROOF DECK ABOVE \ I ` ACOUSTICAL CEILING TILE AS 10'-0" o p s r-- PER SCHEDULE. -6 kl, A.F.F. - _ W-5 "BROSCO" 8006 CROWN MOULDING WITH WOOD o - - - BLOCKING HF_ADER. ACOUSTICAL CEILING TILE AS ! EXTEND GYP. BD. MIN. 6" ABOVE I :.� 1 �- M-5 jP-4 FINISHED CEILING TYPICAL i �— � - PER SCHEDULE. ACOUSTICAL CEILING TILE AS PER SCHEDULE. GROUT _.i' V I y i NOTE: SEE COLOR / FINISH LEGEND 5/8" FIRE CODE GYPSUM BOARD. 8 -9 A.F.F. ��- - I ----�_- 3 5/8" METAL STUD AT 16" O.C. - A.F.F. T ----"BROSCO" #8006 CROWN � 'TILE NOTE: SEE COLOR / FINISH LEGEND �,. 6 FLOOR •t I L_E PATTERN MouLDINc WITH WOOD �'_.5" BLOCKING HEADER. "FORMICA" BLACK PLASTIC LAMINATE i A-5 SCALE: 3/4' = 1 '-0" 7 WALL TILE PATTERN A.F.F. \ 6" METAL STUDS ® 16" O.C. P-4 ; FASTEN TO ROOF DECK ABOVE. - - +-- -3 - I A—5 SCALE. 1 1/2" = 1'-O" „ ' iF-- _� �- 5/8 FIRE CODE GYPSUM BOARD. MENU BOARDS WITH HEADER 2'-4 - OPERATIONS INFORMATION HYPALON ROOFING MEMBRANE ATTACHED TO BACK SIDE R-20 RIGID INLSULATION 8 , BULKHEAD DETAIL _ -- 7'-0" / 1 1 2" METAL DECKING - J/-- / A-5 SCALE: 1 t/?" - 1'-0" A.F.F. - - - - - - - - - 9 BULKHEAD DETAIL W PROVIDE A-j SCALE. 1 1/2" = 1 '-0" I I 6 MIL POLY Q PLYWOOD c; I I I VAPOR BARRIER r i i WELDED - F I FULL HEIGHT FRP - ' 3 X 3 X 1/4" STEEL ANGLE CXJ I I rn I I I LINES OF WALL NOT I 1 r^ SHOWN FOR CLARITY- I I I I 3/8" DIA. THREADED I I WELDED -- STEEL ROD AS REQUIRED DRAWN fim -7 I — --r+ APPR. OD DATE -- — ' ' � �- :LAD WALLS WITH FRP. tOJ9/98 _ -- --T- _ > 1 1 0 1 i r 1 � i SCALE 3-5/8" METAL STUDS CAD FILE I 1 - 0 6" O.C. SUPPORT � CLEAR SILICONE SEALANT AROUND I =" I H:\PAPAGINCI\HYANNIS PERIMETER OF MOP BASIN (TYP.) -—� 1 / - --��` JOB NO. 98066 a o ; I HOOD SHEET - - - -- - - --- I incn j T 10 MOP SINK DETAIL 11 HOOD HANGING ', DETAIL A-5 , SCALE: 3/4" = 1'-O" A-5 SCALE: 1 1/2 = i,._p,. o r1 i I j 0NO. REVISIONS ' DN 1E If .GENERAL ' GENERAL I'I/19/98 cio Z ! f HI ROOF I Q I 4 ! � I 1 1 1 I I 1 1 1 t I -6 I 1 I 1 � 1 Z EXISTING MEMBRANE ROOFING -\ 6" DIA. FLUE `� I I - I e ROOF CAP I `- 1 fs7 r �. HVAC UNIT # 2 8000BS `2_y 1 -6 ! REMOVE EXISTING ROOF AND DECK I t -_. '_._.I I CD - _ ------_ - I AS REQUIRED TO INSTALL HVAC UNIT5. PATCH, REPAIR AND/OR At _ � � ! REPLACE EXISTING ROOFING AND I SLOPE j MAKE WATER TIGHT _6 EXISTING METAL COPING I If v —�, d 8" FLUE---,,, - , EXISTING GUTTER AND DOWNSPOUTS ! I EXISTING STEEL FRAME ---1 { - - r-- EXISTING CURB Q 1 z JJ ! a � I p C) I 1 I I z3 EXISTING HVAC UNIT TO BE RE90VED ----' ' f { { i ; EXISTING GAS LINE ! I ,� ,, 0 I Jul — _ 2�._ _ INSTALL 5/8" EXTERIOR GRADE PLYWOOD, 1 ,, ' INSULATION AND MEMBPANF ROOFING TO MATCH AND BLEND TO EXISTING REMOVE EXISTING ROOF AND DECK AS REQUIRED GAS --- GAS GAS - GAS GAS GAS GAS GAS ----- GAS -- GAS - GAS GAS ` - GAS - GAS__ TO INSTALL HVAC UNITS. PATCH, REPAIR AND/OR I 1 ~^ F_ y REPLACE EXISTING ROOFING; AND MAKF WATER I I _ { TIGHT t / INSTAL.I 5/8" EXTERIOR GRADE I LOW ROOF V_ ,1 4=. _ PLYWOOD. 1 INSULATION AND +I I MEMBRANE ROOFING TO MATCH PROFILE OF EXISTIN - _-L_.-..� --- - - - J 2 AND BLEND TO EXISTING. -� I O t ! I ROOF ABOVE. r.EXISTING EXHAUST FAN L - - - -- " - _. - "- - / \ C'J . -� HVAC UNIT # 1 800LBS I 10" EXHAUST FAN Z r - I Z EXISTING STEEL FRAMC- I Ll. W Q Q F-- }- I - I-i EXISTING WATER HEATER FLUE ' I ! I EXISTING CURB z c i EXISTING HVA(, UNIT - - I m Y + O �_ EXISTING CURB z o �_'------- f �- � w Z i ROOF PLAN `2 � SCALE: i j4" = 1'-0" SURE--SEAL WATER CUT---OFF MASTIC Li I - STAINLESS STEEL CLAMPING RING ��-------GASKET (SUPPLIED W/ CURB} / PRE-MOLDED PIPE SEAL P.T. W���ID NAfLER --� _ ,�� SOLID OR CLOSED CELL SURE-SEAL SPLICING CEMENT RUBBER BACKER ROD 1 -1/2 ____-- _._ - � Q R-20 \ TIMES DIAMETER Of OPENING VENT PIPE:. SEE PLUMBING DRAWINGS / --SURE-SEAL LAP SEALANT RIGID INSULATION �\ FORCE IN & MAKE WATERTIGHT Q - ADHERED MEMBRANE FLASHING ! ( � / REMOVE EXISTING ROOF AND 1 PRE-FABRICATED z I DECK AS REQUIRED TO INSTALL METAL CURB SEE REMOVE EXISTING ROOF AND EXHAUST FAN SEE / VENTS. PATCH, REPAIR AND/OR MECHANICAL DWG'S. Z H.V.A.C. DWG'S- ----- DECK AS REQUIRED TO INSTALL REPLACE EXISTING ROOFING -- 3/4" EXTERIOR GRADE Q I HVAC UNITS. PATCH, REPAIR N EXISTING ROOF AND MAKE WATER TIGHT � F.R.S. PLYWOOD { AND/OR REPLACE EXISTING MEMBRANE �\ i ROOFING AND MAKE WATER METAL f LASNIN�. � TIGHT � '.? - Q.. /--RIGID INSULATION _�.__� _- _ _ -- REMOVE EXISTING ROOF AND DECK AS REOL11RFp TO INSTALL ' .- �,�.�„-,..- _.. __ _- __--.-_>F__-_ -___ _� .._._. • EXHAUST HOOD FAN CURB. , / ND/OP uj FISTING ROOFING �� PATCH, PEP - -INSULATION E { PRE FAB STEEL CURB AND MAKE WATER TIGHT SEE HVAC METAL. ROOF DECK ___, 3 c/ � X F'.T. PIKE EXSIIING METAL ROOF I EXHAUST DUCT SEE RETARDANT BLOCKING z_ / Cn i \ DECKING FILLER MEMBRANE ROOF �`-' MECHANICAL DWG'S f EXISTING _ "x4"x3/8" ANGLE \ -P.T, FIRE I CJ DRAWN / BAR JOIST R-30 PQLYISUCiANURATE ��� WELDED TO 6"x4" / \ BLOCKING 3" AIR SPACE I RIGID INSULATION Z be ' HANGER ,—ANGLE / / 4 � \\FRETARDANT APPR. —__/ MAX. > D -ANGLE HANGER TO BEAR _ j 1„ KALU BLOCK --�. `- ---- --- - -- -- ON TOP OF BAR JOIST. I ATE DO NOT WELD TO JOIST , .- :, CAD SCALFILL 1 4�1-— —0„ --- z \ / H:\PAPAGINO\HYANNIS ' 1013 No 98066 2 LAYERS 5/i3" FIRE --AREA of sFlEer -- ( ' EXISTING — - — � CODE GYPSUM BOARD � RENOVATION m E N --- - - -- - -- - - --- --\\,_L -- ROOF JOIST -- _ PL aJ 4 _ DETAIL OF EXHAUST HOOD FAN CURB - 3 DETAIL OF VENT THRU ROOF A-6 SCALE: 1 1/2" = V-0" :-6 , DETAIL OF RTU CURBSCALE: 1__ 1/2KEY PLAN A SCALE: 1-1/2" 1'-0" HVAC AND FAN CURB (Ty n. J- NIJ. REVISIONS DATE I GENERAL GENERAL 11/19/9 COLOR/ FINISH I_._EGFND _ _'- ---- - WINDOW DETAILS - TAG MATERIAL_ MANUFACTURER PATTERN _ L COLOR & FINISH - NOTES NAME ANL NUMBER FLOOR FINISHES GLASS INSULATING FLOOR TILE (DINING AREAS) METROPOLITAN CERAMICS 4%8" QUARRY TILE 310 MAY FLOWER RED PROVIDE 6%6" COVE BASE AS REQUIRED. 1 F-t ' INSULATING GLASS -ii-- 2 FLOOR TILE KITCHEN UAL TILE 6"x6" QUARRY TILE, 'NON-SUN 041 BLAZE FLASH PROVIDE t)"xb" COVE BASE A5 REQUIRED IN KAWNEER 4S1T � ON �� (KITCHEN) WINDOW FRAMES ' CARPET SHAW CONTINENTAL ROCKPORT i^ ED ':_ 868 TRENTON NYLONO\A VINYLN STRIPS --- '~ zim N i SEALED CONCRETE DURAFLEX DURA--FLEX DURAGLAZE #4 CLEAR SHORT BLAST CONCRETE 1 ` F_5 STAIR TREADS NORD -- - - 465-4' STAIR TREAD 0702 BLACK --- - __-----.-----`--------- --- f�-= KAWNEER 451T CEILING FINISHES WINDOW FRAME. C 1 CEILING TILE (DINING AREAS) ARMSTRONG SECOND LOOK U �767TA CORTEGA COLORS TAN 24"x48"x5/8" SCORED 24%24" FINE FISSURED HAZE i w � 7 f. VINYL GYPSUM PANEL USDA STIPPLED WHITE 24"x48'•x5 8" -- EXISTING DOUR I C-z CEILING TILE (KITCHEN) USG ( ) / '2 _ - _ � C_3 PAINTED GYP. BOARD - - CEILING WHITE - d — - - 2 JAMB DETAIL —4 MULLION DETAIL I WALL FINISHES —_ ---- = A-. w-1 DADO PANELING MARLITE - WOOVENE^ E��E IEi�S HUNTF:R`GREEN - \/�-7 " SCALE: 1 1/2" = 1'-0" A-7 SCALE: 1 1/2" 1'-0" I' a CUSTOM BY MILLWORK CONTRACTOR O P-�-NK-801- - ---- _ - -» -- �� WALL COVERING #1 ` N—GN NTRA- WALL L-51 -DV MAYAuTYPE DOVER 54" WITH STAIN RESISTANT FINISH /i - E3�} WALL COVERING MURAL CAN C. .APHIPAPA PAPA GiNO'S - CUSTOM - -11 _ w WALL TILE (FIELD) A.MERI('AN OLEAN 95 SNOW MIST 1" INSULATING EXISTING STRUCTURE GLASS /� W NDOWRFRAME w-5 WALL TII E (ACCENT i ) AMERICAN OL FAN 103 HUNTER GREEN -- - --- 1 ACOUSTICAL CEILING (wD WALL TILE (ACCENT #2) AMERICAN OLEAN 110 BURGUNDY _ I KAWNEER 451 T TIt E _ ---- - -- - ---- --_- -.__ _ �' L- I_ ` t J} -vIA -1. HEAVY-DUTY M S c I N / i, MARLITE PAN 5 ` 1 � ,I E TEXTURED. --- WINDOW DOW FRAME WITH INSULATION' FILL r ' t1r NE - 11�3 NATURA A Iv(0 USE MAT�HiNG HEAVY-DUTY EAMS REINFOR w 7> FRP PANELS (RESTROOMS) CORED FL ISH D 4x4 R WAJrI< i tLt (KITCHEN) MAkLI I E (((����J�pppj�Ay' KAWNEER 451 T WINDOW FRAME NE 1 St S UI R _QUARDS - __ P SHIM �� WALL COVERING #< AC WALL- 2--51-DV MAYArTYPE L OTANICAL WITS STAIN RESISTANT FINISH T ` BACKER ROD AND a -�, —1 " wSUTATNG L� OV-RIP _ i _ I -� CAULKING ALL SIDES 1i GLASS 1 " INSULATING f GLASS MISC FINISHES -1 COUNTERTOP FOUNTAINHEAD BY NEVAMAR FR-6-6 FEDERAL CORNERSTONE WITH ROUND EDGES No NOT USED —__ _5_ ILL-DETAIL 6 HEAD DETAIL 7 JAMB DETAIL cat M-3 NOT USED - -_ - A--7 SCALE. 1 1/2" = 1'--0" A-7 SCALE: 1 1/2" = 1'-0" A--T SCALE: 1 1/2" = 1'-0" .M-4 GROUT (FLOOR TILE) MAPEI 10 BLACK -- 5 GROUT (FLOOR TILE) MAPEI-00 WHITF - _ - M PLASTIC LAMINATE FORMICA BLACK #840 MATTE FINISH MENU BOARD SOFFIT -- ._ .� ------ - ----- -- -------- -- --- ---- -- - � I /^ 1 x WOOD STOOL CAP PAINTS - �i> WOOD STAIN SHERWIN WILLIAMS WIPING SATIN CONCENTRATE S64 N 42 RAW UMBER � I� Q p Z PAINT BENJAMIN MOORE ALMOND SEMI-GLOSS --_ BASEMENT AND CEILING -- KAWNEER 451E 3 _6 � I Q � 3 PAINT - BENJAMIN M00RE BLACK GLOSS ALL H.M. DOORS, FRAMES, & HANDRAILS WINDOW FRAME A F.F Z_ N (� PAINT BENJAMIN MOORE 1088 BEIGE ABOVE CHAIR RAIL - -- - - -_ ?�- 1x4 WOOD TRIM, z - _ ATTACH TO MULLION r- Z PAINT BENJAMIN MOORE 1090 TAN BELOW CHAIR RAIL I1 Lij ,t — P 6 PAINT (EXTERIOR) BENJAMIN MOORE 1093 CREAM - -_ _ EXTERIOR TRIM - _ 1" INSULATING �j 'I 1" INSULATING n- _ --- - (� r - GLASS - -�--- -+ II CLASS HARDWARE SC; HEDULt I TYPICAL DOOR �E 1tiIL5 - ------ ---�------------ ---- --------------------------- --- -- - ------ ----- 3 5/8" METAL STUDS _ - 3 5/8" METAL STUDS TAG QUANTITY DESCRI TION H- 1 1 ALUMINUM DOOR WI i H A WiDE STILED DOOR, SUCH AS KAWNEER SERIES 500 DOOR - - C� 16 O C /-� • 8 JAMB DETAIL 9 —� RAIL C� GLAZING ' o 0 SYSTEM. PROVIDE STANDARD MANUFACTURERS HARDWARE, AND PULL AND PUSH BAR. 1/2" GYPSUM BOARD A-7 SCALE. 1 1/2" = 1'-0" A-7 / SC,ALE: I I/Z' = 1 '--U ' CPO1 PANIC. HARDWARE WITH DISENGAGING CYLINDER. VON DUPRIN OR EQUAL -� 1 112 PAIR BUTTS: 5"x4" HAGER BB 1279 /-- 1/2" GYPSUM BOARD 1 DEAN BOLT: SCHLAGE, WITH DISENGAGING CYLINDER. ' - - - ---- - - --- ----I a 1 CLOSER: SURFACE MOUNTED, DORMA HOLLOW METAL FRAME AS 1 THRESHOLD. ALUM. MILL FINISH, SADDLE OR HALF SADDLE STYLE (ACCESSIBLE) I PER DOOR SCHEDULE. rj LJ1 1 SEAL_: SET GASKETING AND S11.1 SWEEP. E---- H(_1Lt_OW METAL FRAME - WELDED OR SNAP IN STEEL AS PER DOOR SCHEDULE L-1 1 STUD ANCHORS MIN. 3 PER H-2 1 ALUMINUM DOOR WITH A WIDE STILED DOOR, SUCH AS KAWNEER SERIES 500 DOOR IAMB. SYSTEM. PROVIDE STANDARD MANUFACTURERS HARDWARE, AND PULL AND FUSH BAR. 1 1/2 PAIR BUTTS: 5"x4" HAGER BB1279 I A HEAD DETAIL LB JAMB DETAIL 1 CLOSER: SURFACE MOUNTED, DORMA SCALE 1 i/2"=1 '-0" A— SCALE 1 1 ' H--31 1 1/2 PAIR BU71 51 4-1/2", HAGER. BB1279 ---- - -� �A_-'' 1 CLOSER: SURFACE- MOUNTED, DORMA I - 1 KICK PLATE: PUSH SIDE ONLY, HAGER 34"x 12" US32D. - —_--- -_- -.-- --- -- - __- -- --- i2�, 1 WALL STOP: HAGER 234 D O O R TYPES _1 1 RUSH PULL 1 H-4 1 1/2 PAIR BUTTSc' 4-1/2" HAGER BR 1279 i- 1 EXIT DEVICE` VON DUPRIN 99NL A4" TEMP. E �' ' „ SAFETY GLASS I � 2 ��"-mac_ 1 CLOSER: SURFACE MOUNTED, DORMA '3 1 DOOR STOP: KICK DOWN, HAGER NS208 US26D (RECEIVING DOOR ONLY) 1 p�ANO" c�-- 1 ARMOR PLATE: HAGER 40"Wx36"H US321.) 1 LEXAN SECURITY WINDOW NEW STAMP, LEXAN 10%10" (DOOR #9 ONLY) - DOOR #i ONLY 1 THRESHOLD: HAGER 4325 1 GASKET SET: HAGER 8735 I I a l 1 SILL SWEEP: HAGER 7505 STORAGE ROOM LOCK: SCHLAGE, LEVON LEVER ONLY. (ELECTRIC ROOM ONLY) H-5 1 _ _ NOTE: ALL CYLINDERS TO BE BEST WITH REMOVABLE CORES. w F_ RC'OM FINISH SCHEDULE AL-1 HM-1 5C-1 L TYPICAL METAL FRAME FLOORS WALLS _ 1 RM. N0. ROOM NAME F CEILING ( REMARKS I - - - DOOR S C H E D U L E- -- WISH BASE - (� c� - -` 100 VESTIBULE F-i) F-1 CLASS C-t) MAT SEE NWGA _ � � -- - -�` REFER INTERIOR FINISH � •--•-���•• ---111 DOUR FRAME HARD- 101 DINING ROOM F-t F—s P-t w-1 w-2 c-1 TAG DOUR DESCRIPTION TYPE TYPE WARE O O O-- OO----- - O aTIQN5-A_ --- - -- _ �' 102 WAITING w-�I w-1 > C-1 0 3' _0"x7'-0"x 1 3/4" ALUM. STOREFRONT DOOR -AL-1 ALUM. H-1 SEE NOTE BELOW `co i 03 CORRIDOR ��� (t t w-8 P S P-4 �� .2 3'-0"x7'-0"x 1 3/4" ALUM. STOREFRONT DOOR AL--1 ALUM. H-2 SEE NOTE BELOW 104 MEN F-' F 7 C_3 �� 3'-O"x7'-0"x 1 3/4" SOLID CORE WOOD DOOR SC- 1 H.M. H-_ CD 105 wOMFNS F✓2 w-� c_j 4 3'-n,>.7 -n"x � ,4" SOLID COPE WOOD DOOR SC--1 H M. H-3 rp-1 frn M F-2 P-1 �J w=2 w-7 C-3 5 3'-0"x7'-0"x 1 3/4" HOLLOW METAL DOOR HM-1 H.M. H-4 P-3 DRAWN 106 SERVICE _-- t; - -- ---- - -- --- --- - ----------------- _ - - -- APP . 107 COOKLINE F-2 (P-1) w w-2 ( C-3 6 EXISTING DOUR AND FRAME PD 108 ( PIZZA F-2 (F-2 W-4 w-5 W-6 `1 ----j- 7 EXISTING DOOR AND FRAME NOTE DA E -- - 8 `2 ti EXISTING DOOR AND FRAME. ("� — -- —_ SCALE AS NOTED 09 KITCHEN _ .-_-- U -PAINT COLOR SHALL MATCH EXISTING ADJACENT -- z 110 WALK-IN COOLER - - _ 9 jEXISTING DOOR AND FRAME � WINDOW FRAME COLOR. p_ ; CAD FILE ,.. - - P-2 10 EXISTING DOOR AND FRAME ill i FREEZER F-2 O P-3 H:\PAPAGINO\HYANNIS Cr P 2 )08 NO 98066 ) 1 t EXISTING DOOR AND FRAME P-3 a 112 DELIVERY d F-�- � — ------ .__- _.- SHEET Lc Lo 0 m (f1 cr F !r r Y T cn c u ti n ti a. i [� NO. REVISIONS lIl U - ' ` i GENERAL 1 V t Z { (J ---- _—_ .__......._za] �j Z O ' c, F 2 �", 129 SOi 1Q2C 1 32 {t 32 X w 513 .516 �09 ' - w - GREASE TRAP B'r G.C. I 7le --- - �� �. I '' 3 5 i 305 305) C305 30 o i 109 I 12 31� l312 3`1 l 312 r FXISTI G RESTROOM i 5t0 52� 11 t 1� t30A �' 206 t 11 - 1 13 5 504 1 Q 1 130A 501 \ 1 18 i 18 _ - \ 7ti ,. o ►•-+ 1306 147 130B ^ 120 - -- - - - -I Ll ✓ti' `MAP AREA 524 I '1 40� 402 _ FOR DELIVERY o ' - - - L3=1 3t0, 31G 310 310 ! 2q 1 14 5Q 1 122)j1W ) KI TCHEN I I 137 143 148 (144� 142 141� 141 — <-- a � o. _ 524 Q-- 135, COOK LINE - 6 1 31 150� 109 l`_24} .. , _._. b J w ' 6 /,1 ; 310- 11 403 03 1031 46 02A�� 522�125 1ax48 H f 133 I - ct mplo - _ f i �, - �— 1 I . (345 305 3G5 301 301 ' 02 I 4 J - 1 1 17 v 130A �148 312 (3 t?) �2 404 00 - - -- - - - - - P4K60 24x60 I C1 I ro - �05 (Q2� 136 I, - - _- ` (307 307 c I-. _ 124� PIZZA I -- ---- 149 =—=__ 41 C va DELIVERY 1.34 - 124 FREEZER �___..., 1 � , � 111 - �i8 I t 15 307 <307 307 �3� L301.rI x 12� - j 14x4 ABOVE I 20� I 123 -:a. � (124 124 12D Y1 _ I - -- -- - -- -- - -- - II f 308 ) �308 �- '� � _ - - � _ - - - - � 1331 130 1� B 107 / 01 °D — i- - �-� i ----� 1 10 (_2 7 1 19 1 1 t 0 \ ! 1 _ ... ,,. 7 2 Z - -_ I 1 524 - - - - -----� 1 2'-0 PASS THRU COUNTER y �301 �3Q1 �30 301 301� 301� ; N 0 24-60 L, + 1 4. 3 'ar? 'ax�4 t�f4 �1�'t�[�}p I I � �� - Z j x ! 1 . I „ �L' !1` _.__._ .. 524 x - - `-�� 512 40 ` �0 J rvj O - { _ `-_ o O 6 O o __ i XESTIBULE tr 1 2_ 2 �9 402 mot• z _-._-- _-_�..__.___.____.-_ _.__ ._______._.�_..r:._.� i � DINING O I E 3 123 - -- -- qpLr) 1,, f \ T f 101 ] / 100� o Z 3 _ _ ;J I co k .; 118 104 1OS 203 I I Iuj `n n o `� I \ CORRIDOR F\ "`1 �-- l -, V) 520 _k,. \ 1031 ' I 130A -1 5/gL 108 1 514 LLJ 403 403 (403 403 i t_ n0 g _ T a WOMEN I I C , L i - �\ of , � I to E'1 \ ---- � � �� i - I < (301 7=30- - _ - . - WAITING t: w _ � - - - --- ---- - - - E�139 - - ._- I - - ---�-•�--: � XISTING CnLI `i _ 50 -� (308 3U8 1 � 305 513 L {513� MEN �- { j %?r 208 ' 0 i -- 123 �-- 104 <._. .s 312 312 I. I 5�2 301 (301 - ❑❑ r - - -- - - - -- -- - -- — - f 0 - (527 52b �' -- 208� � I L i 310 302 O5 --- �. - - '"� OF -- - _ -_ -PROFILE ABOVE. II 511 51'3 519 I (31� (310 110) 310) 310 I O ��_ ' 303 303 303 303, 3Q3 5G3 525 525 525 25 �>_ __ Pf) V) �- 305 305 (305 305 305 MMON HALL - _ - '-- f1 '~ Z 114� 519 519 C3 4� - 304 4� (3) 304 I f 3 t 2 312, 312 312 312 527 526��0 01 52b� �52fi� F1 �� - ( Q Z - 311 �1t ] 311 ' 3t1 ICI I I (l _� < ` 1� � ; tom, �t / I EQUIPMENT PLAN SCALE: 1/4" L. ... I r Q O O \rt`ri i D � m0 o I I I Z U L. W EXISTIN ' RESTROOM 11� II - i L-10 z � GENERAL FOOD SERVICE GENERAL NOTES: .HEALTH DEPARTMENT NOTES: i. U.0 TO VERIFY ALL DIMENSIONS IN FIELD PRIOR TO INSTALLING EQUIPMENT. 2. G.C. OR OWNER TO PROVIDE SUFFICIENT ACCESS FOR DELIVERY AND FOR 1. ALL NEW EXHAUST HOODS WIIL BE CONSTRUCTED TO MEET INSTALLING EQUIPMENT. THE FOLLOWING STANDARDS: NSF, UL, AND NFPA - 96 HOODS 3. G.C. TO PROVIDE WOOD BLOCKING BEHIND ALL WALL SHELVING, HOSE ARE TO MEET ALL LOCAL GOVERNING CODES. REELS, ETC., LOCATION OF BLOCKING TO BE VERIFIED BY EQUIPMENT LEGEND SUPPLIER. (L 2. ALL COOKING EQUIPMENT UNDER EXHAUST HOODS ARE EITHER 4. WHERE WALL PANEL IS REQUIRED, G.C. OR OWNER TO PROVIDE ON CASTERS W/ FLEXIBLE UTILITY QUICK DISCONNECT$ OR FIXED CLEAR. STRAIGHT WALL. 0 FLOOR DRAIN ON STAINLESS STEEL LEGS AND SEALED TO WALLS W/ CLEAR 5. G C. AND OWNER TO PREPARE ENTIRE SITE TO MEET ALL FIRE, HEALTH SILICONE SEALANT. AND BUILDING CODES IN ORDER THAT ALL AREAS SURROUNDING AND * DENOTES EO UIPMENT NOT IN CONTRACT 3. ICE MACHINES TO BE HELD OFF WALL 8" IF VACUUM BREAKER AGAINST WHK.'H THE EQUIPMENT IS BEING PROVIDED ARE NOT IN VIOLATION 7 IS REQUIRED BY CODES IT WILL BE FINISHED BY THE PLUMBING OF ANY CODES. Z CONTRACTOR. 6. G.C. TO PROVIDE 5 8" F.R.S. PLYWOOD BLOCKING AT ALL Y&ALL. Lli cv H.W. HOT WATER 4. CABINETS OR COUNTERS WITH EXPOSED FOOD OR CLEAN MOUNTED EQUIPMENT AND ACCESSORIES. C W. COLD WATFR UTENSILS WILL BE PROVIDED WITH DOORS OR NO OPEN SHELVING W DIRECT WASTE BELOW 18 INCHES ABOVE FLOOR. '.2 1 W INDIRECT WASTE 5. THE HOODS AND EXHAUST DUCT SYSTEMS WILL BE PROVIDED F.D. FLOOR DRAIN WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM. F.F.D. FUNNEL FLOOR DRAIN 6. ALL REFRIGERATION EQUIPMENT SHALL HAVE THERMOMETERS WHICH G. GAS ARE EASILY READIBLE, IN PROPER WORKING CONDITION, AND cy B.G. BOTTLE GAS ACCURATE, WITHIN A RANGE OF PLUS OR MINUS TWO DEGREES. ] m B.1'.U. BRITISH THERMAL UNIT 7. COUNTER TOP EQUIPMENT NOT READILY MOVABLE, WEIGHING OVER 3I W V. VOLTS 80 POUNDS WILL BE PROVIDED WITH LEGS OR FEET AT LEAST SEAT COUNT: _. H.P. HORSEPOWER FOUR INCHES HIGH. `n K.W. KILOWATT 8 ALL CHEMICAL SANITIZER KITS FOR THREE (3) COMPARTMENT SINKS AMP AMPERE WILL BE FURNISHED B'Y THE CHEMICAL SUPPLIER. _ 2 � S.R. SINGLE RECEPTACLE FROM A VACUUM BREAKER OR AIR GAP TO PREVENT POSSIBLE TOTAL SEA15 84 DRAWN D R DUPLEX RECEPTACLE BACK SIPHONAGE OF THE CHEMICALS INTO THE WATER LINE be, TM, am C' PH PHASE SYSTEM. APPR o A.F.F. ABOVE FINISHED FLOOR 10 ALL FOOD SERVICE AND RELATED EQUIPMENT SHALL BE INSTALLED z IN CONFORMITY WITH NSF STANDARD AND SHALL BE NATIONAL DATE B.T.C. BRANCH TO CONNECTION 10/9/98. - c SANITATION FOUNDATION (NSF) APPROVED. SCALE 3 CENTER LINE 1 4" = 1 '-0"D.F.A. DROP FROM ABOVE 11 AN AISLE SPACE OF 30 INCHES MINIMUM OR MORE SHALL BE -- - _ � -- S. STEAM INLET PROVIDED WITHIN ALL WORK AND SORAGE AREAS- CAD FILE R. STEAM RETURN 12. BACKSPLASHES OF EQUIPMENT SHALL BE INSTALLE A MINIMUM OF H:\PAPAGINO\HYAPINIS i C.F.M. CUBIC FEET/MINUTE OF 3 INCHES FROM WALL OR SEALED TO WALLS. AREA OF --- - ---------- - COL COLUMN 13 VACUUM BREAKERS WHEN USED TO BE MINIMUM OF 6 INCHES RENOVATION �� N0 98066 J.B. JUNCTION BOX ABOVE THE FLOOR LEVEL RIM WITH NO SHUT OFF DEVICES BEYOND SHEET C.P. CORD AND PLUG THE DISCHARGE OF THE VACUUM BREAKER 14. NO OVERSHELVES TO BE PROVIDED OVER COOKING AREA. z 15. PROVIDE A MINIMUM OF 20 FOOT CANDLES OF LIGHTING IN ALL FOOD PREPARATION AREAS AND SERVING AREAS AND INCLUDING _ WALK--IN BOXES. LIGHTING TO BE SHIELDED OVER EXPOSED o FOOD AND UTENSIL AREAS. I 16 HANDWASHING FACILITIES ARE REQUIRED FOR FOOD PREPARATION, KEY SERVING, OR UTENSIL WASHING AREAS AND WILL BE SHOWN ON K E L PLAN z THE FLOOR PLAN. z: NO. REVISIONS DA rE 0 SCHEDULE OF EQUIPMENT MECHANICAL_ CONNECTIONS Z�l\ GENERAL 11/3/98 z z 2 ITEM 109 11/19/98 7 < I R E M A R K S Li :D ELECTRICAL PLUMBING REQUIREMENTS DESCRI PTION — MAKE- MODEL VOL I HP JAMPS CWI WLQWJIWJFDJGA S JMBTU RN. 1W I FUR N. 101 1 POT SINK THREE PART. / ADVANCE / 94-43-72-24R 1/2-11/2" 1.5" PC GO PLUMB W/ (2)FAUC-ETS(BY PAPA GINO'S), DRAINBOARD (RIGHT 10' 1 REFRIGERATED WORKTABLE / CONTINF�NTAL / SW60-BS 120 GC ELEC -.-W/CASTERS, (4)DRAWERc;, H.DUTY SLIDES & FRAMES 1 X PG 102A I REFRIGERATED SMIDWICH UNIT / CONTINENTAL / SW72-27M 120 1 1/4 8.7 1 x PG GC JELEC _W/CASTERS, SPLIT CUT'G. BID., (4)DRAWERS, ADAPTERS 102B 1 RFFRICEPATOR (UNpERCOUNTFP)_ ,/ CONTINENTAL / CRB42 120 1 t�-4 6,1 x PC, CC ELEC -W/(2)_DRAWERS, H.DUTY SLIDES & FRAMES, CASTERS PG GC 102C POT FILLER 102D 1, 2 1DUNNAGE RACK PC GC 1 103 12 SOUP SAUCE'WAWt9 7 WE'S / SS:-I-OTbr (BOLLTLK) -208 1 -�62 tj..o- X iL�-3" K-, IV, - ELEC, W DRAW & fHERMOSTAf, BUILT fNTCr +TEW # 146 104 1 1 PIZZA PREP REFRIGERATOR / CONTINENTAL / CPT67 120 1/3 8.8 x PG GC ELEC iW/ CASTERS, ADAPTERS, SPLIT CUTTING BOARD >. TRAY RACK / METP 105 2 RF3N (PORTABLE) I PG GC —W/ 3" SLIDE SPACING, LOCATED IN COOLER ,ET48LE _PREP SINE OL-30--7- (END 1 1/2" 1/2*11.5 1 1 04 Z 106 1 1 VFC _�D\�ANCE SPLASH)- PC GC PLMB -----W/ 1,2)FAUCE-TS (PY PAPA GINO'S), DRAWER, CUT'G BD 107 1 jFRUIfOPiA DISPLAY CASE / VENDOR / (GLASS DOO!!I_ 120 1 1.0 X PC PG ELEC COUNTER TOP UNIT 108 EA PIZZA PQUN0--CUT TABLE Z Cl.Y70M 4' x 3', x 3' PC Cc Wl/ PAN SLIDES, INT. SHELF, SLIDINC, SHELF, RFCFSS f oq i IFREEZ R .(STAND-JUP) Z CONTINENT I AL _1-p 120 1 1/3.7.6 X PC JGC ELEC W/ (2)DRAWERS, H. DUTY SLIDES & FRAMES, CASTERS �rll t SODA 'ICE DISPENSER 7 CUE'U (DROP-IN) 120 1 7115 COKE COKE ELEC/PLMB ICW FILTERED THRU ITEM # 1.39 Ix 112 11 ill 2 HAND SINK Ll ADVANCE / -7--PS-80 1/2"Il/L 1.5" PC GC PLMB_)tZ FAUCET, LEAP DRAIN, TOWEL/SOAP DISPENSER 1 1)- 112 1 COFFEE BREWER / BUNIN-0-MATIC Z CWTF TWIN) LP�S 120 208 1 6.2 26 x PG GO ELEC 'PLMB C.W FILTERED THRU #I 39,(2)AIRPOTS,(I)APR2--RACK 113 - DISHMACHINE (UNDERCOUNTER) / JACKSON JP-24--BF 208 1 6.7 3/4 38 X 112" 1.5" PG GC PLMB ELEC VERIFY USE W1 EACH PROJECT It! 114 1 ICE MACHINE MANIT,--!WOC 11 0 C-470 BIN 120 1 12.9 X /2". 4: FG IGC PLUMB ELEC C.W. FILTERED THRU #139, I.W. TO HUB DRAIN 115 1 MENU CUSTOM BY PAPA GINO'S) 120 1 X PC CC ELEC BY PAPA GINO'S SEE SHOP DRAWINGS 116 1 ;MICROWAVE OVEN / SHARP R--22ET 120 1 2.0 20 x c CC ELEC. VERIFY NEED FOR (1) ADDITIONAL (W/EACH PROJECT) 117 1 JPIZZA OVEN / BAXTER/ OV851G-M-18 MODIFIED �GAS) 120 1 7.0 X 1 300 PG GO PLMB ELEC PC PG_ ELEC VERIFY PHONE QUANTITY W/ PAPA GINO'S 118 1 PHONE SYSTEM / AT&r. _0 1 x 119 1 PIZZA SLICE WARMER � HATCO / EST-lX I-)o 1 1.68 14 x PG GC ELEC W11 4" LEGS fmwwp*'l!lo- 120 1 PASTA COOKER PITCO / PC--14D (L;004�.ER ONLY} -(GAS120 1 3.0 1 X 1/2" 1/2"1 1.215, T7'0 _L/2 775 PC GO PLMB/ELEC W/ AUTO LIFT, AUTO FILL-,- FAUCET, CASTERS 121 1 COOLER-FREE :C'X8'-6"H 1-3 150 X PG GC ELEC/HRC W/ H.D HARDWARE, FLOOR FREEZER, REMOTE REF 122 PREP TABLE / ADVANi-L/TAf3CG / �vs305) PG GC -W/ UTILITY DRAWER (SS-2020), CASTERS i-zs-- -4 IFLOOR_SHELVING METRO 5N557RR 24�X 5-TIER PC GC VERIFY SIZES W1 EQUIP. PLAN (SUPER ERECTA BPffET 124 6 COOLER SHELVING METRO 5N547K2 124" X 5-TIER PC GO VERIFY SIZES W/ EQUIP PLAN (METROSEAL ll�_ 125 1 SODA SYSTEM / COKE USA (CAR NATOR) UNDER #1 0 1120 1 _1/3 X 1,12- COKE COKE ELEC PLMB_VERIFY EQUIPMENT W/ COKE USA 126 1 HAG -IN--BOX RACf-, j t:OKE Ll:>A COKE COKQ VERIFY' EQUIPMENT A/ COKE USA 127 3 CUP DISPENSER SWEETHEART SMALL, MEDIUM, LARGE PG GO BY PAPA GINO'S) BUILT INTO ISLAND COUNTER #202 128 6 CHECI- MiNDER (BY PAPA GINO'S) PC GC EXPENDABLE ITEM PACKAGE, PAPA GINO'S TO LOCATE 129 1 PIZZA BAG HOLDER / METRO / 5N5378R 24" X 48" 5-TIER PC CC AT DELIVERY AREA, VERIFY SIZE (SUPER ERECTA BRrTE sil 130 1 bF.IVLRA(A MERCHANDISER VENDOR I (GLASS DOOR) 120 1.0 X PC IPG ELEC FLOOR MODEL 130A 6 SPLASH MOUNT SHELVING TABCO / PT-12S- PG JGC - SPLASH MOUNT, (2) 0 VEG. SINK, SEE PLANS eR 1,308 1 UTENSIL RAC*_j 1 PC iGc - SPLASH M 'INK _�lAB�-_O /_AUR--.72 MOUNT, 0 POT 7, 131 LOT COKE CONTAINER COKE COKE VERIFY EQUIPMENT W/ COKE USA NER (BAG-I N-BOX) 132 4 QUICK-DISCONNECT HOSE / DORMONT / (3)I6b0KIT-2S (4'),(1)1675-2 (4') 1/2"-3/4" PG GC PLMB W/ DOUBLE SWIVEL, PASTA COOKER, FRYERS GRIDDLE 133 2 CUTTING TABLE / ADVANCE TABOO KMS-306_(1-6L72:)(1-4 -0*) PC 6c DRAWER (SS-2920 SEE PLAN FOR SIZES —GC , 734-P,c CABINET � EC6 / CUSTOM PG 135 - BREADSTICK WARMER / WELLS RWT-I 6(1)DRAWER(BUILT-IN) 208 1 36 x PC CC - W THERMOMETER, BUILT INTO # 144 136 1 EXHAVST HOOD (PIZZA OVEN �A TLF' (BUILT INTO #.117) 120 1 17.0 X PC GC ELEC PART OF #117 (PIZZA OVEN) 137 . I EXHAUST HOOD (GRILL AREA) GREENHECK / G�JAW(9'-O') . 120/208 3 .0 PG GC ELEC CONTR. FILTERS, LIGHTS, FANS & DUCTS (BY GEN �38--T- EXHAUST HOOD (P TA COOKER) /GREENHECK /GC (3*X3'X21 120 pi- 1/31 27 X PG GC ELEC W/ FILTERS, LIGHTS 139 1 WATER FILTER SYSTEM_/ FVFRPI)RF 9328-06 x PC CC VERIFY LOCATION 140 - 6 DISPENSER / PERLICK DplKP �PORTABLE) 120 -33 x PC GC ELEC W/ DOOR LOCK, STANDARD FINISH, (VERIFY USE) 141 2 FRYER PITCO /14(FLOOP MODEL) (GAS) SF-14 FILTER 120 1/3 84 X 1/2110 PC GC JPLMB W/ S/S POT & DOOR, CASTERS, BUILT-IN FILTER 142 1 IDUMP STATION / PITCO / BNB-I (FLOOR MODEL) PC GC W/ BF-14 FILTER(UNDER), CASTERS LFGFND -i 471 1 IGRfDDLF / WELLS / WG-243F)r' (COUNTER MODEL) (GAS) 3/4" 75 PG CC PLMB W,� STANDARD FEATURES 144 1 GRIDDLE STAND / ADVANCE-TABCO / ES7303 PC GC W/ CUTTING BOARD(TA-923), CASTERS(TA-255) 145 1 FIRF PROTECTION SYSTEM / ANSUL. P-102 CC GC PLM6 AT PIZZA OVEN, PASTA COOKER, GRIDDLE STAND V) ABBREV. DESCRIPTION ABBREV. DESCRIPTION 146 1 SOUP SAUCE COUNTER / LAROSA CO. / L-90102-32 PG GC W/ CUT -OUTS FOR (2)#103,_ UNDERBODY, LEGS V) (A 147 1 VEGETABLE CLITTE0 / NEMCO / N55200AN (171'r PAPA GINO'S) PG G,C I W,/ VEGETABLE CHUTE, MOUNTED TO # 106 0 c vv GOLD WATER 208/1 VOLTAGE PHASE 14b BREAD DISPLAY CASE / CUSTOM BY PAPA GINO'S) PG PG (1) 0 CENTER ISLAND, (1) 0 GRIDDLE STAND Z (N — HOT-WATER K W KILOWATT COOKING PC (,I C ON BACK SIDE OF 1 202, (PROVIDE SHOP DRAWINGS)H W 149 S/S WALL SHEATHING / CUSTOM S/S FABRICATION (BEHIND I (D ff) W DIRECT WASTE HORSE POWER 150 1 ]BUS CART d--f 1 4- i , Z I W INDIRECT WASTE D R DUPLEX RECEPTACLE - RK z �',AS i B JUNCTION BOX -- I`\/l I L LW U < B T U BRITISH THERMAL UNITS S R SINGLE RECEPTACLE 201 1 l,r,ARRY-01-IT UNIT / CUSTOM / MILLWORK (BUILT-!N 0(7- CC -ON #202, SEE MILLWORK DRAWINGS Li < F FD FUNNEL FLOOR DRAIN V VOLTS 202 1 ]CENTER ISLAND COUNTER / CUSTOM / MILLWORK Gc Gc SEE MILLWORK DETAILS F- >- F Cj FLOOR DRAIN A AMPERAGE 203 1 SERVICE COUNTER ,` ;'�U,70M / MILL-WORK GC CC SEE MILLWORK DRAWINGS, VERIFr LENGTH CL w 'T F S FLOOR SINK B T C BRANCH TO CONNECTION 204 - WALL SHELF / CUSTOM / MILLWORK GO GO SEE MILLWORK DETAILS (VERIFY USE WZ EA. PROJECT) S S STEAM SUPPI Y S W SWITCH 205 1 lCONDIMENT COUNTER / GIJ5TOM / Mil-LWORK CC GC SEE MILLWORK DETAILS _ __ i' C R CONDENSATE RETURN D F A DOWN FROM ABOVE 206 1 PHONE CENTER STORAGE COUNTER / CUSTOM MILLWORK I GO IGC SEE MILLWORK DETAILS, VERIFY LOCATION & SIZE I I i GC GC SEE MILLWORK DRAWINGS, VERIFY LOCATION C F M i-i)BiC FEET PER_MINUTE A F F--A80VE FINISHED FLOOR 207 - MANA(-,EP"7 DESK / MILLWORk c & P CORD AND PLUG G C GENERAL CONTRACTOR 208 4 SINGLE TRASH UNIT I CUSTOM MILLWORK GO GC SEE MILLWORK DRAWINGS 0 -) /I CUSTOM / MILLWORK SEE MILLWORK DRAWINGS p C PLUMBING CONTRACTOR PG --PAPA--fl-mo- 209 1 1,�ASHIER STAND E C ELECTRICAL CONTRACTOR 210 ISPARE NUMBER I SPARE NUMBER FURNITURE 301 14 PG PC GENERAI-- N 0 T E'S 302 1 WAITING BENCH�LlJ' GC GC - SEE MILLWORK DRAWINGS Illy _STQM MtLLWORK 303 5 2-SEAT BOOTH TABLE TOP MILLWORK / 28" 24" GC GC - SEE LAMINATE SPECS- NOTE #4 1) SEE KITCHEN EQUIPMENT MANUAL FOR SPECIFICATIONS & ACCESSORIES- 304 5 BOOTH 2.,--SEAT / MILLWORK / (FINISHED BASE 0 WINDOWS) GO -GC - SEE MILLWORK DRAWINGS 305-- 5 BOOTH 4-SEAT / MILLWORK / (FINISHED BASE 0 WINDOWS) Gc GC - SEE MILLWORK DRAWINGS VERIFY MANUFACTURER, MODFL DESCRIPTION W/ COMPLFTF WRITTFN SPECIFICATIONS. 306 WALL bENL;H /I (-'USTOM / MILLWORV 19' -6'*L G(l SEL MILLWORK URAWINGS, VERIFY LENGTH r 307 1 7 2-SEAT TA LE BASE/ 30"H GC GO 2-SEAT TABLE TOP / CUSTOM 2) THE REFRIGERATION CONTRACTOR ISRESPONSIBLE FOR INSTALLING (IN REMOTE LOCATION) 308 1 7 -- K / 241 - ;2�4'D - GC GC SEE LAMINATE SPECS ALL. COMPRESSORS & EVAPORATORS FOR THE COOLER/FREEZER 309 [ LOTIBOOTH FILLER / CUSTOM / MILLWORK (AS REQUIRED) PC GO SEE MILLWORK DETAILS 310 15 4.- SEAT BOOTH TABLE TOP MILLWORK, / 28" , 44" GC JGC SEE LAMINATE SPECS-- NOTE #4 (SEE MECHANICAL DRAWINGS i`-OR LOCATION) 311 5 BOOTH 2-SEAT TABLE. BASE (FREESTANDING) -GC IGC 312 15 BOOTH 4-SEAT TABLE BASE (FREESTANDING GO GO 3) THE FOLLOWING ARE OWNER PROVIDED ITEMS: 313 - OUTDOOR TABLE/_42-0/ PG GC VERIFY MANUFACTURER W/ PAPA GINO'S LJLJ 314 OUT[) R CHAIR/ PC GC VERIFY MANUFACTURER W/ PAPA GINO'S (UNLE"-:-)S INDICATED OTHERWISE IN THE GENERAL CONTRACT)- 315 OUTDOOR PATIO RAILING/ PC GC VERIFY MANUFACTURER W1 PAPA GINO'S -SOUND SYSTEM -AWNINGS- ELECTRIC CONNECTIONS BY G.C. SPARE NUMBER -FIRE EXTINGUISHERS (PER LOCAL CODE): INSTALLED BY G.C. 317 SPARE NUMBER Ed -It-- -FIRE PROTECTION (ANSUL): INSTALLED BY MANUFACT, -SECURITY SYSTEM: INSTALLED BY G.C. SE6FE NUMBER P 0 IS SYSTEM -MENU BOARDS- INSTALLED BY G.0 -SIGNA�,E (ALL LOGOS, EXTERIOR & INTERIOR SIGNAGE) PC PG ELEC 401 1 1 CASH ADVANCE CHELSEA--N.C.R. 120 1 X -PHONE SYSTEM -WALL MURAL: INSTALLED BY G.C. 1 11 402 TERMINAL / -CHEL7,EA--N C.R / 290-160 120 1 h o X PG PC ELEC -WATER FILTRATION SYSTEM: INSTALLED BY G.C. -PLANTERS/PLANTS 403 6 tPRINTER / CHELSE.A-N.C.R, / 2561 120 1 1,0 x PC PG ELEC 404 PROCESSOR / CHEI-SEA--N.0 R. / 3240 120 x PC PG ELEC 4) THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING & INSTALLING 405 POWER MODULE N.C.R. 4096 120 X PC PC ELEC THE PLASTIC LAMINATE REQ'D. FOR ALL TABLE TOPS INDICATED ON DRAWING #F---1 406 SPARE NUMBER AS FOLLOWS: TABLE FIELD-PAPA GINO'S TRADEMARK LAMINATE 467 SPARE NUMBER NOTE: ALL TABLE TOPS TO HAVE OAK BULLNOSE EDGE G E N E R A L Ld 501 `1:-PLA.SH GUARD I Gc GC VERIFY SIZE AND MATERIALS_ W/ SPEC., WALL MOUNT 5) ALL BOOTH BASES TO BE FINISHED ALL FOUR(4) SIDES AT WINDOWS. 502 2 HAND DRYER / 120 1 X GC: GC ELEC SEE ARCHITECTURAL DRAWINGS 21 503 1 JUKE Bux ROWE / RI-5-160 1211 1 1 1 0 X I PC CC ELEC IVENDOR MELLOTONE 504 1 jMOP SINK (BY GENERAL CONTRACTOR GO GC PLMB VERIFY SIZE W/ ARCHITECTURAL DRAWINGS 1 1/2 1 505 i - "0 1 X I PG GC ELEC VERIFY USE W EACH PROJECT 506 1 1 PC PC EXPENDABLE ITEM, VERIFY LOCATION Cf) THIS DRAWING IS A SINGLE PART OF AN INTEGRATED SET OF CAN OPENER ,/ D m- 507 1 OULLEIIN BOLRI_/_ PC GC EXPENDABLE ITEM, VERIFY LOCArON ED CONTRACT DOCUMENTS. REFER TO ALL DRAWING AND 1. 0 CONSTRUCTION 508 -1- FIRE EXTINGUISHER PC GC VERIFY LOCATON$ .3: SPFCIFICATION SHEETS INCLUDING, 91 IT NOT LIMITED To "GENERAL 501� Z' 'lJWLL DISPENSEP GC G(, I :SEE ARCHITECTURAL DRAWINGS CA LAJ CONDITIONS" AND "SUMMARY OF WORK", AND APPLICABLE SPECIFICATION 510 I- HOT WATER HEATER A.O. 'SMITH BT-80 3/4'15 GC GC PLMB FLOOR SECTIONS WHICH APPLY TO THIS DRAWING. REFER TO ALL DOCUMENTS FOR 511 101 TfALEJ PARTITION BY GENERAL CONTRACTOR) - CC GC %/ERIFf SPECS W/ ARCHITECIURAL DRAWING #SP- 4 lk. cn THE COMPLETE SCOPE WORK. THE CONTRACTOR WILL BE RESPONSIBLE FOR 512 1 1 MICROPHONE 11 MUSAC 120 1 x PC PC ELEC VENDOR: MELLOTONE (VERIFY LOCATION) m ALL INFORMATION CONTAINED IN THE "SET" OF [,I)CUMENTS ISSUED THIS 513 71 SOAP DISPENSER PG CC -VERIF( LOCATIONS, SEE ARCH. DRAWINGS m DRAWING IS SCHEMATIC AND IS NOT TO BE USED AS A SHOP DRAWING. 514 1 SAFE / NEW ENGLAND SAFE CO./ IC3K PG GC W/ INT'CH'G CORE LOCKS, UNDER SERVICE COUNTER DRAWN bc ALTERATIONS FROM THAT SHOWN REQUIRED TO COORDINATE WITH OTHER 515 -01 SANI CENTER PC GC RIFY LOCATIONS TRADES OR TO CONFORM TO ACTUAL SITE CONDITIONS ARE THE 5116 -OT I MIRROR GC GC VERIFY LOCATIONS, SEE ARCH. DRAWINGS APPR. CONTRACTOR'S RESPONSIBILITY. ELECTRICAL, MECHANICAL, AND PLUMBING 517 GUMBAL MACHINL PG -Er, ATION 0 ENGINEERS SHALL ADAPT THIS DESIGN FOR THE ACTUAL SITE 518 OFFICE CHAIR PC GC IN OFFICE AREA, EXPENDABLE ITEMS DATE 10/9/98 REQUIREMENTS. THIS INCLUDES SIZING OF ALL PIPES AND HVAC UNIT 519 4 GRAB BAR / BOBRICK / B-450-42 GC Cc 4-- SEE ARCHITECTURAL DRAWINGS T') / LYONS 121818-BM cu 520 1 EMPLOYEE LOCKERS GO G , GRAY (12/SET), VERIFY LOCATION SCALE -0" BASED ON LOCALITY AND LOCAL CODE REQUIREMENTS. VERIFY THE 5-)! VERIFY LOCATIONS, SEE MECHANICAL DRAWINGS 1/4-'.'..-=- -'---------- LOCATIONS OR DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL OT HVAC EQUIPMENT Z ---/ u U�.l CAD FILE 522 -OT CARPET (DINING AREAS) PG CC VERIFY AREA REQUIRED, SEE ARCH. DRAWINGS � Jr ELEMENTS WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS ISSUED, 523 il VESTIBULE MAT GC GC SEE ARQHITL�TURAL DRAWINGS H:\PAPAGINO\HYANNIS U r\j THE SHOWING OF THESE ELEMENTS ARE FOR REFERENCE ONLY AND ARE TO 524 LOT CORNER QUARD-ENDCAP FRP G c Gc -::tvLSIF`Y SIZE AND MATERIALS WZ SPECIFIQATION5 JOB NO. 98066 OF VERIFIED PRIOR TO DESIGN OR CONSTRUCTION NO LIABILITY IS ,VIDEO 5 4 GAME ix I i I PC i-lG ELEC VERIFY" USE W1 LACH PROJECT ASSUMED BY THE INDICATION OF THE ELEMENTS IN THESE DRAWINGS. 526 2 ITOILET PAPER DISPENSER SHEET CID 2 1 SANITAR'f NAPKIN DISPOSAL 1�21 r,"� I rwaKY11MC.' TABLE/IRUBBERMAID/STURDY STATION/ U) F 10 LS:� 7 0 X 0 X 120/2 2 7 - X X 3 1 2 1.5" C" NO. REVISIONS I DATE GENERAL 1t/19/9 B 1/ CA) --J m 33'-4 1/4" 33'-4" 35'-5" z - x LL1 I Z HI ROOF W E I r n 6" DIA. FLUE ►�' _i ROOF CAP a k o N M�1 eiJ \ \ co � —--- - w t"I po 1___:___l I It `t x x y cp ! . cu 6x4x3j8 L I,i am c; I rl 0 r F•� / I a) L/ EXISTING 28" BAR JOISTS 6x4x 8 L ____--._-_-- _.. __ _ LLJ O i c u3, G� 4ry `-AC UNITS 800 LE35 a j ��, i II W 0 0 �` 0 Z 1 W L�. ° q O X Q tiW f I lU t� c Z I I W Qed ° �E ids t I jcn cn ��. Q +� EXISTING 8"0 STEEL COLUMN x It a i Y EXISTING 28" BAR JOISTS w � ` 0 m - - NL �i ' Z EXISTING 8"0 STEEL COLUMN —� `� l I I 00 �..,. w --- --- - — "' AC UNITS 800 LBS 6x4x3/8 L I (n Q I 0 � -- _--- ------ EXISTING 28" BAR JOISTS _ - - Z N ., I -PROFILE OF EXISTING Z Q .�.�•� I ROOF ABOVE. z � � Q 00 rj c`1 x X � i x x x x UD ��. �� �� i ..�. .�.r �:��■ I I .�� � ..^...�i. �.� .��.� ..urn � .��. � �.��� � i � � �.� ! O � 1 i I C L___—� I I I O O Z I f I I J0 cr_ I I -- - - ---- -- - -- ---- — z 0 F 3 - -' tI) O x Z I LJ I ROOF FRAMING PLAN d.. I ,-4" = 1'-O„ �t Q STRUCTURAL STEEL AND METAL ROOF DECK: V" W 0 1. STRUCTURAL STEEL TO CONFORM TO THE REQUIREMENTS OF THE AISC. MATERIAL SHALL CONFORM TO ASTM SPECIFICATIONS INDICATED (ASTM A572 GR.50) V. 2. WELDING SHALL COMPLY WITH THE REQUIREMENTS OF THE AMERICAN WELDING SOCIETY. 0 3, CONNECTIONS SHALL BE AISC STANDARD UNLESS OTHERWISE NOTED SHOP CONNECTIONS WELDED; FIELD CONNECTIONS 3;4" HIGH STRENGTH BOLTS. 0 4. PROVIDE TEMPORARY BRACING TO HOLD STEEL IN PLACE DURING ERECTION. 5. SHOP PAINT STEEL, NOT ENCASED IN CONCRETE, WITH GREY OXIDE PRIMER. ' 6. STEEL ENCASED IN EXTERIOR MASONRY WALLS TO BE COATED WITH BITUMIN. ? STEEL ANGLE LINTELS IN PAIRS SHALL BE PLUG WELDED OR BOLTED TOGETHER AT 2'-0" ON CENTER. PROVIDE 6" BEARING AT EACH END UNLESS OTHERWISE NOTED. n, BRAWN be cr: APPR. DATE 10/9/98 SCALE 1/4" 1,_0" CAD FILE o, c _.— ----------. — ------- H:\PAPAGINO\HYANNIS AREA OF RENOVATION J08 N0. 98066 0 SHEET a-a r G KEY __ LA_ ���.. ; NO. REVISIONS I DATE _._-_--------.... .--} ----- PAPA GINO'S D. Do not use concrete which becomes nonp►astic and ROUGH CARPENTRY SECTION 06100 3.4 REPAIR: JOINT SEALERS SECTION 07900 WOOD DOORS SECTION 08212 unworkable, or does not meet the required quality control limits, or A. Repair damaged and defective finish carpentry work ______ which has been contaminated by foreign materials. Remove wherever possible to eliminate defects functionally and visually - - � '-- SHORTFORM GUIDE SPECIFICATIONS SECTION 00100 rejected concrete from the site and dispose of it in a location PART 1 - GENERAL Where not possible to repair properly, replace woodwork. Adjust PART 1 - GENERAL: PART 1 - GENERAL- _ _____ __ approved by local authorities. joinery for uniform appearance. _ I DIVISION 1 - GENERAL REQUIREMENTS: E. Consolidate placed concrete by mechanical vibrating 1.1 SECTION INCLUDES: 1 1 SECTION INCLUDES: 1.1 SECTION INCLUDES. - -------- .. --- equipment, hand-spading, nodding or tamping, in accordance with A. Provide wood nailers, blocking, backing, and plywood 3.5 CLEANING: A. Provide sealants complying with requirements included A. Provide flush wood doors, and install where indicated on the ACi recommended practices. required for completion of the work, which is generally not exposed, A Clean on exposed and semi-exposed surfaces. Touch-up herein, in order to establish and maintain airtight, vermin proof, and drawings, as specified herein, and as necessary for a complete and --- ------•----_.- The Genera! Conditions AIA Document A201 shall govern the work of this T 4 P 9 Y P g rY P �� - F. rowel Finish: Apply trowel finish to stab surfaces that are to where noted on the drawings, and as specified herein. Note that in shop applied finishes to restore damaged or soiled areas. waterproof continuous seats on a permanent basis. Failures of proper installation. Specification. be exposed to view and to slab surfaces that are to be covered with 3.6 PROTECTION: installed sealant to comply with this requirement will be. recognized non-combustible buildings all concealed wood blacking must be fire- - � P Y q 9 1.2 QUALITY ASSURANCE: --- - resilient flooring, carpet, ceramic or quarry tile, or other thin-film A. Installer of finish carpentry work shall advise contractor of as failures of materials and workmanship SELECTIVE DEMOLITION SECTION 02070 r• retardant treated. P A. Quality Standards for Flush Wood Doors: Comply with I.S.I. ,nish coating system final protection and maintained conditions necessary to ensure that " G. Fill--in holes and openings left in concrete work for passage 1.2 DELIVERY, STORAGE & HANDLING: work will be without damage or deterioration of time of acceptance. "industry Standard for Wood Flush Doors", of National Woad P 9 A. Kee materials under cover and d Protect against gPART 2 - PRODUCTS: PART 1 - GENERAL of work by other trades is in place. Mix, place aria cure concrete as p �' g Window and Door Association (NWWDA). Comply with herein specified, to blend with in-place construction exposure to weather and contact with damp or wet surfaces. Stock END OF SECTION 06200 Architectural Woodwork Quality Standards": including Section 1300 1.1 SECTION INCLUDES H. Curbs: Provide monolithic finish to interior curbs by stripping to provide for air circulation within and around materials, and under 2.1 MATERIALS A. Removal and legal disposal of existing interior and exterior forms while concrete is still green, and steel-troweling surfaces to a temporary coverings. A. Provide sealant where noted on the drawings and at the "Architectural Flush Doors", of Architectural Woodwork Institute following locations: (AWI) for grade of door, core construction, finish and other y, <;2ri- construction items specified to be removed aria as indicated on the hard, dense finish with corners, intersections and terminations requirements exceeding those of NWWDA quality standard. 01 m Drawings. The work includes, but is not limited to, removal of the slightly rounded. PART 2 - PRODUCTS INSTALLATION OF ARCHITECTURAL CASEWORK - 1. Base cabinets to adjacent walls & floors q 9 q Y Z �N 2. Countertop, sink units to countertops B. Safety Glazing Standard: Provide safety glass of type Z ,J C following items, incorporation of these items into the Project are not SECTION 06400 P !�-+ 3.2 PROTECTION: 3. Countertops to loose backs lashes and walls indicated or required by authorities having jurisdiction for doors and - permitted. 2.1 MATERIALS: P P ✓� A Protect the fresh) laced concrete from premature drying 4. Sink units to adjacent walls sidelights, comply with ANSI Z97.1 and testing requirements of 16 < cc 1. Existing counters, cabinets and fixtures; Y P P ry g A Lumber: Comply with PS 20 of "American Softwood Lumber 1 W from wind, excessive cold and hot temperature, and maintain fora PART 1 - GENERAL: 5. Countertop backsplashes to adjacent wall finish CFR Fart 1201 for Category II materials except where those of 0.4 o 0 2. Interior partitions, doors and windows; Standard" and with applicable grading rules of inspection agencies period of time necessary for hydration of cement aria proper 6. Pipes, sleeves, chutes, duct and other similar Category 1 are expressly indicated and permitted. a ":. 3. Floor finishes aria base, and ceiling materals, certified by ALSC Board of Review. Provide dressed lumber, S4S t i SECTION INCLUDES: tQt hardening. penetrations through partitions includingsuspension wires and framing; unless otherwise noted, seasoned wl�rYt6isture content for 1.3 DELIVERY, STORAGE, & HANDUNG: ' 9i A Architectural casework furnished by the G C , where 7. Non-mobile food service equipment to floor or 4. HVAC, plumbing and electrical systems, END OF SECTION -03300 sizes 2" or less. For light framing, provide construction grade or indicated in the drawings and as specified herein. to adjacent counter & walls. A. Protect doors during transit, storage, and handling to prevent IP4i including conduits and control wiring. better, of any species. 1.2 DELIVERY, STORAGE & HANDLING: A. Acrylic - Latex Sealant: Permanently flexible emulsion type, damage, soiling and deterioration. Comply with requirements of w 0 r B. Wall Blocking or Backing: Minimum 2 x ,6 fire-retardant A. Deliver inserts and other anchoring devices to be built into nonstaining and nonbleeding, recommended by manufacturer for referenced standards and recommendations of NWWDA pamphlet ,r, 1.2 PROJECT CONDITIONS: treated lumber between partition studs, or stud face applied layer of substrates well in advance of time substrates are to be built "How to Store, Handle, Finish, Install, and Maintain Wood Doors", U i- to A. Owner assumes no responsibility for the actual condition of METAL FABRICATIONS 05500 general interior exposure. +� V p y 5/8" thick fire-retardant treated APA C-D PLUGGED plywood Condition wood materials to average prevailing humidity conditions items or structures to be demolished. The existing structure is concealed behind face layer of gypsum board or wall paneling, as in installation area prior to installation. B. Single Component Sanitary Silicon Rubber: Mold/mildew as well as with manufacturer's instructions. H unoccupied. indicated. Provide where indicated in the Drawings and where c resistant, acid type sealant for application to nonporous sealant B. Deliver doors in original unopened containers with labels U a P PART 1 - GENERAL 9 1.3 SITE CONDITIONS bond surfaces. intact and legible at time of use. Store under conditions '-`16cv required for anchorage support at wall mounted shelves, A. Verifyfield measurements and provide dimensions for recommended b the manufacturer =,. =1.3 ASBESTOS INSPECTION & REPORT. C, Silicon Rubber for Food Service Equipment Installation; G.E Y G 1.1 SECTION INCLUDES: accessories. grab bars, wall mounted hand sinks, tables, and other casework shop drawings before fabrication. c IaA. If required by the Environmental Protection Agency's A. Provide items of steel shapes including, but not necessarily similar locations. b s 12 it or equal single-component oriel part silicone-rubber . "National Emission Standards for Hazardous Air Pollutants" limited to rough hardware, loose steel lintels for new masonry C. PI wood Backin Panels. For mountin electrical, securit based airncuring non-sag tacteias thferic sealant complying with FDA 1.4 SITE CONDITIONS:Y 9 9 Y• PART 2 - PRODUCTS: requirements for direct contact with food products. DO NOT A. Do not deliver or install doors until conditions for temperature 9� (NESHAP), provide the services of an inspector to evaluate the openings when applicable) steel framing and supports, and or telephone equipment, provide fire-retardant treated plywood, and relative humidity have been stabilized and will be maintained it-, 9 ( PP ) 9 PP provide sealant with mold and mildew-resistant materials when Y project site for the presence of Regulated Asbestos Containing miscellaneous steel trim. APA C-D PLUGGED INT with exterior glue, 3/4" thick. 2.1 MATERIALS: Materials RACM's The inspector shall be lawfully D. Fasteners and Anchors: Provide size, type, material aria A. Fasteners and Anchors: Provide size, type, and material as materials will be in food-preparation areas of the project. storage and installation areas during remainder of construction �_1111 ._,,.......>.,,,,,,.,.,��,.,.,..„,_:,... (RACM's). p y D. Joint Backer: Use only those back-up materials which are period to comply with requirements of the "Architectural Woodwork qualified/certified to perform such inspections by applicable federal, 1.2 EXISTING CONDITIONS: finish as recommended by applicable standards. Where rough noted on the drawings, and if not noted, as recommended by y specifically recommended for this installation by the manufacturer or Quality Standards" including Section 100-S-3 "Moisture Content" of state and local regulations. Provide a minimum of ten (10) working A. Field Measurements: Check actual locations of walls and carpentry work is exposed to weather or is in ground contact, applicable standards. the sealant used, and which are non-absorbent and nor.-staining AWI. � y }• accurate field measurements before fabrication; show recorded provide fasteners and anchorages with a hot-dip zinc, tooting B. Provide other materials as indicated in the drawings and as E. Masking Tape: For masking around joints, provide masking days notification to the appropriate office of the EPA's Asbestos 9 P 9 1 9 measurements on final shop drawings Coordinate fabrication meeting ASTM A-153. otherwise required for completion of the work of this section. toe conforming to Fed. Sec Ut1-T-106c. Hazard Management Department, whether RACM's ore found to P 9 D PART 2 - PRODUCTS: exist or not. Unless otherwise indicated, demolition or abatement of schedule with construction progress to ovoid delay of work. E. Provide hot--dip zinc coating (ASTM A-153) fasteners and F Other Materials: All other materials not specifically described i$ . anchorages where rough carpentry work is exposed to weather, in PART 3 - EXECUTION: but required for complete and proper caulking and installation of 2.1 MATERIALS: RACM's will not be included in the scope of work. PART 2 - PRODUCTS ground contact, or ;n an areo of high relative humidity. Z11 F. Fire-retardant treatment shall provide a florae spread rating 3.1 INSTALLATION: sealant, shall be first quality of their respective. kinds, new aria as A. Solid Door Flush Woad Doors: AWI Section 1300. Custom PART 2 - PRODUCTS (Not Applicable) selected by the contractor subject to the approval of the owner. grade, construction meeting AWI Spec Standard #PC-5; c� •; u� -A 2.1 MATERIAL of Less than 25. Provide fire--retardant lumber grade stamped by A Install the work plumb, level, true and straight with no '' r Y; �. particleboard core with 5-ply pre-manufactured face veneer, natural . �a�_t, e A. General: Provide metal forms and types that comply with manufacturer, where required distortions. Shim as required using concealed shims. Install too <, 8 - YP PY q q g PART 3 - EXECUTION: finished birch veneer both sides. Subject to compliance with � �, o��;� s PART 3 - EXECUTION: requirements of referenced standards and that ore free from surface tolerance of 1/8" ,n 8'-0" for plumb and level, and with 1/16" `"A. ""-0 -0 3.1 EXAMINATION: requirements included herein, provide wood doors manufactured byU:ci} Q. blemishes where exposed to view ;n the finished unit. Exposed-to- PART 3 - EXECUTION maximum offset in flush adjoining surfaces and 1/8" maximum 3.1 INSTALLAT1W one of the following: A I A. Inspect areas in which work will be performed prior to view surfaces exhibiting pitting, seam marks, roller marks, stains, adjoining j y g 'g' rt� A offsets ,n revealed ad oinin surfaces. A Clean joint surfaces immediately before installation Prime or 1. Algoma Hardwoods � commencement of demolition work d;scolorotions, or other imperfections on finished units are not 3.1 EXAMINATION: B. Scribe and cut to fit adjoining work, and refinish cut surfaces seal joint surfaces as recommended by manufacturer Comply with 2• Buell Door Company kA.- B Locate, identify, stub-off, and disconnect existing utility and acceptable. A. Discard units of material with defects which might impair or repair damaged finish at cuts. manufacturer's instructions. Fill sealant robbet to a slightly concave 3. Eggers Industries services lines that are not to remain. Provide by-pass connections B Cold-Formed Steel Tubing: ASTM A 500, Grade Q, unless quality of work, and units which are too small to use in fabricating C. Anchor to anchors or blockingbuilt-in or direct) attached to 4. Architectural Door Division as required to maintain continuity of service to other areas of the otherwise indicated work with minimum joints or optimum joint arrangement. y surface, slightly below adjoining surfaces Where horizontal joints �,�,� 1 P 1 9 substrates. Secure to grounds, strapping and blocking with are between n horizontal surface and vertical surface, fill joint to 5 Graham Manufacturing Corp. building, if necessary. f C. Hot-Formed Steel Tubing: ASTM A 501. 3.2 INSTALLATION: countersunk, concealed fasteners, and blind nailing as required for form a minimum 1/4" radius convex cove, so that joint will notrtrap 6. Weyerhauser Company. D. Steel Plates, shapes and Bars: ASTM A-36. A. Set rough carpentry work accurately to required levels and a complete installation. Except where prefinished matching 3.2 DEMOLITION: moisture and dirt. ��� � -�-' �� E. Welding Electrodes and Filler Metal Provide type and alloy lines, with members plumb and true and accurately cut and fitted. fastener heads are required, use fine finishing nails for exposed 2.2 FABRICATION: A. Perform demolition work in a systematic manner. Use such of filler metal and electrodes as recommended b producer of metal B. Secure) attach carpentry work to substrate b anchoring A. Fabricate flush wood doors to produce doors in sizes methods as required to complete the work required ,n accordance y P Y P Y Y 9 nailing, countersunk and filled flush with woodwork, and matching 3.2 CLEANING: indicated for job-site fitting. Comply with tolerance requirements of to be welded and as required far color match, strength, and and fastening as required final finish where transparent finish ;s indicated A. Do not allow sealant to overflow joints or to spill onto AWI Comply with final hardware schedules and door frame shop with requirements of governing regulations. compatibility in fabricated items. C. Use common wire nails, except as otherwise indicated. Use D install cabinets without distortion so that cabinet doors and B. If unanticipated utilities, structural elements, or hazardous F. Nonshrink Nonmetallic Grout: Pre-mixed, facto packaged,ed, f;nishin nails for finish work Select fasteners of size that will not adjoining work, or to migrate into voids of exposed finishes- Clean drawings and with hardware templates. 0 tZ rY-D 9 9 drawers fit openings properly and are accurately aligned. Adjust adjoining surfaces b whatever means may be necessa to B. ShopPriming: Shopseal faces and edges of doors for materials are encountered, investigate and measure bath nature f g Y y ry g' g nonstaining, noncorrosive, nongaseous grout complying with CE penetrate members where opposite side will be exposed to view or hardware to center doors in openings and to provide free and extent of the conflict. Submit report to the Owner in written, CRD C621. Provide rout specifically recommended b will receive finish materials Make tight connections between eliminate evidence of spillage. transparent finish with stain (if required) and other required Q accurate detail. Pending receipt of directive from the owner, g P y Y 9 operation Complete installation of hardware and accessory items pretreatment and first coat of finish as specified in Division-9 Z manufacturer for interior and exterior applications of type specified members- Install fasteners without splitting of wood, predrill as indicated 3.3 PROTECTION: section "Painting". N V) rearrange selective demolition schedule as necessary to continue ;n this section. required. E. Tops. Anchor securely to base units and other support M overall job progress without delay. G. Shop Primer Paint for Steel and iron: Manufacturer's systems. A. Cure sealant in compliance with manufacturers instructions C Existing Resilient Floor Coverings: Comply with standard rust - inhibiting primer, compatible with finish coats of ENO OF SECTION 06100 PART 3 EXECUTION: �- Z aria recommendations, to obtain high early band strength, internal "Recommended Work Practices for the Removal of Resilient Floor cohesive strength and surface durability. Replace or restore Q Z paint. Coordinate selection of metal primer with finish paint 3.2 REPAIR: sealant which are damaged or deteriorated during construction 3.1 INSTALLATION: 0- W Q Coverings", as published by the Resilient Floor Covering Institute. requirements specified in Division 9. A. Repair damaged and defective casework to eliminate defects A. Openings: Cut and trim openings through doors to comply Existin resilient floor covering materials may contain asbestos period. Protect installed sealant from damage from construction CL Q W }" 9 9 Y H Fasteners: Shall be zinc-coated fasteners for exterior use or FINISH CARPENTRY SECTION G6200 functionally and visually, or where not possible, replace casework. with applicable requirements of referenced standards for kind(s) of fibers that are not readily identifiable. Do not sand, dry scrape, when built into exterior walls as follows: Adjust joinery for uniform appearance. Clean, lubricate and operations until owner occupancy. doors required. _ beadblast or mechanically pulverize existing resilient flooring, 1 . Bolts and Nuts: or hexagon head type, adjust hardware for smooth operation. Rehang or replace doors B. Manufacturer's instructions: install wood doors to comply backing, or lining felts. ASTM A-307, Grade A. PART 1 - GENERAL: 3.4 SCHEDULE OF SEALANTS: which do not swing or operate freely, as directed by owner. with manufacturer's instructions and of referenced AWI standard partitions: Acrylic and walls p ry w t m frames o as lic latex. 2. Lag Bolts: Square head type, FS FF-8-561 Clean casework on exposed and semi-exposed surfaces. A Doorand as indicated. _._-- 1.1 SECTION INCLUDES: B. Toilet fixtures to wall joints: white, sanitary silicone with mold 3.3 PROTECTION: 3. Machine Screws: Cadmium plated steel, FS Touch-up shop applied finishes to restore damaged or soiled C. Job-Fit Doors: Align and tit doors in frames with uniform A. Chair rail trim molding, picture rail molding where noted on and mildew resistance. A Provide temporary barricades and other forms of protection FF-S-92. P g areas. clearances and bevels as indicated below; do not trim stiles and t the drawings and as specified herein. C. Food service equipment installation: clear silicone sealant rails ,n excess of limits set b manufacturer or permitted with fire- O as required to protect the Owner's personnel and the public from 4. Plain Washers: Rounded Carbon Steel FS FF-- g D B. Touch-up finishing as required by installation. Comply with y' P r,, 1 1.2 QUALITY ASSURANCE: referenced quality standard for sanding, fillip countersunk without mold or mildew resistance. rated doors. Machine doors for hardware. Seal cut surfaces after any injury due to demolition work. y�/-g2, q Y 9� 9 5. Toggle bolts: Tumble wing type, FS FF-B-588, A. Quality Standards: Comply with "custom grade" fasteners, sealing of concealed surfaces and similar items. fitting and machining. Provide 1/8" at jambs and heads; 1/16" per 4 requirements of applicable provisions of the Architectural ENU OF 5ECTiON 07900 leaf at meeting stiles for airs of doors; and 1 8" from bottom of 3.4 DISPOSAL: Type, class and style as required. q PP P g P / � �. A. Remove debris, rubbish and other materials resulting from 6. Lock Washers: Helical spring type carbon Woodwork Institute (AWI) "Quality Standards 3.3 PROTECTION c door to top of decorative floor finish or covering. Provide radius I demolition operations from building site Transport and dispose of Steel, FS FF--W--84. 1.3 DELIVERY, STORAGE & HANDLING A. Provide final protection and maintain conditions in a manner METAL DOOR & FRAMES SECTION 08100 edges at meeting stiles of pairs of wood doors. Where threshold is .� materials off-site in a legal manner. A. Do not deliver finish carpentry materials until painting, wet acceptable to fabricator and installer, which ensures architectural shown or scheduled: provide 1/4" clearance from bottom of door to 9 7. Grilled-in Expansion Anchors: Expansion P Y P 9� P �-, _.,.._- anchors complying with FS FF-S-325, Group VII (anchors, work, grading and similar operations which could damage, soil or woodwork being without damage or deterioration at time of PART 1 -- GENERAL: top of threshold. D. Field-Finished Doors. Refer to Division--9 section "Painting" 3.5 CLEANING: expansion, (nondrilling), Type I (internally threaded tubular deteriorate woodwork have been completed in installation areas. substantial completion. g A. Upon completion of demolition work, remove tools, expansion anchor); and machine bolts complying with FS FF- 1.4 SITE CONDITIONS 1.1 SECTION INCLUDES: for finishing requirements. equipment and demolished materials from the site. A. installer shall advise contractor of temperature and humidity END OF SECTION 06400 A. Provide metal door frames and hollow metal doors, where B-575, Grade 5. requirements for finish carpentry installation areas Do not install 3.2 ADJUSTING: noted on the drawings and as specified herein. Comply with A. Rehang or replace doors which do not swing or operate END OF SECTION U2070 ., , finish carpentry until required temperature and relative humidity FiRESTOPPING - SECTION 072 70 q Y P 9 g�.2 FABRICATION: conditions have been stabilized and will be maintained in installation applicable requirements of the Steel Door Institute "Recommended free) Refinish or replace doors damaged Burin installation. A. General. Use materials of size and thickness indicated or as Specifications. Standard Steel Doors and Frames " required to produce strength and durability ;n finished product for areas. 1 2 PERFORMANCE REQUIREMENTS: 3.3 PROTECTION: CONCRETE WORK SECTION 03300 use intended. Preossumbie oil items possible in the shop to FART 1 - GENERAL. A. Labels Where noted in the drawings, or where required by A. Protect doors as recommended by door manufacturer to minimize field splicing and assembly Disassemble units only as PART 2 - PRODUCTS: g ensure that wood doors will be without damage or deterioration at the Building Code to be constructed of fire-resistive construction, g PART 1 -- GENERAL. necessary for shipment and handling limitations. Disassembled 1.1 SECTION INCLUDES time of substantial completion. 2.1 MATERIALS: A Firesto in materials complyingwith requirements included provide "UL" or "Warnock--Hersey" tested and labeled products. items shall be clearly marked for reassembly PP 9 1.1 SECTION INCLUDES B Weld corners and seams continuously, complying with AWS A Wood trim: Oak - 3/4" thick. herein, in order- to maintain fire--resistive assemblies END OF SECTION 08212. recommendations At exposed connections, rind smooth ex. osed B. Fasteners and Anchorages: Provide nails (meeting FS FF- PART 2 - PRODUCTS A. Provide cast---in--place concrete for patching of existing floor P grind P slabs, complete, in place, as specified herein, and as required for a welds and flush to match and blend with adjoining surfaces. Form N-105), screws (meeting FS FF-S-1 1 1), and other anchoring PART 2 - PRODUCTS: 2.1 MATERIALS: complete and proper installation exposed connections with hairline joints, flush and smooth, using devices of the type, size, material, and finish required for application A. Drywall Frames 18 gouge cold-rolled steel, knock-down concealed fasteners wherever possible. Use exposed fasteners of indicated to provide secure attachment, concealed where possible, 2.1 MATERIALS. B. Saw cut existing concrete slab as required for installation of P P type, with resilient bumpers equal to 5teelcroft series SW-16-4 new underground utilities. type shown or. if not shown, Phillips flat-headed countersunk and complying with applicable quality standards. A. Fire caulk: UL listed one-part, non-sag, elostcmeric, g yp p (countersunk) "Easy-Set" drywall frames. Provide 18 gauge, drywall frame screws or bolts. C. Condition wood materials to average prevailing humidity f;restopping material intended to seal cracks, voids or holes, 0 PART 2 - PRODUCTS C. Provide concealed fasteners for interconnection of handrail conditions in installation areas prior to installation. complying with ASTM E 119 and ASTM E 814 to achieve required anchors welded to frame, 4 anchors per jamb minimum. aria railing components aria for their attachment to other work fire rating. Products meeting above require t are B. Exterior Doors: 1-3/4" thick insulating assembly with 18 Z requirements include, but PART 3 - EXECUTION: y limited to the following materials gauge cold-rolled hot-dipped galvanized sheet steel faces, flush not necessarily 2.1 MATERIALS except where exposed fasteners are unavoidable or are the type with top, bottom and oil edges fully welded and ground smooth. Series 100"STI" SecSeal A. Reinforcing Bars: ASTM A-615, Grade 60, deformed. standard fastening method for handrail and railing system indicated. 1. P Provide weep holes at bottom to allow escape of entrapped --- B Welded Wire Fabric: ASTM A-185, welded steel D. Provide for anchorage of type shown, coordinated with 3 1 EXAMINATION: 2. "Dow Corning" Fire Stop Sealant #2000 C. Protland C factor of not less than R-11. Cement. ASTM C-150, Type 1, low alkali. supporting structure. Fabricate and space anchoring devices to A Discard units of material which are unsound, warped, bowed, moisture. Door panel shalt provide thermal insulating resistance �--- D. Normal Weight Aggregates: ASTM C-33, crushed limestone, provide adequate support for intended use. twisted, improperly treated, not adequately seasoned or too small to PART 3 - EXECUTION granite or equivalent material from a single source. Maximum E. Shop Painting. Shop point miscellaneous metal work, except fabricate work with minimum of Joints or optimum jointing C. Exterior Frames: 14 gauge hots dipped galvanized cold-rolled arrangements, or which are of defective manufacture with respect T steel, fully welded. Provide minimum of 4 galvanized wire type, >� aggregate sizes shall be not larger than one-fifth of the narrowest members or portions of members to be embedded in concrete and 9 P 3.1 INSTALLATION: corrugated sheet metal, or expansion type anchors per jamb. U dimension between sides of forms, one-third of the depth of slabs, galvanized surfaces unless otherwise noted. Remove rust, scale, to surfaces, sizes or patterns A. Clean substrate surfaces immediately before installation. r„ or three-fourths of the minimum clear spacing between individual and other deleterious materials before applying shop coat, clean off 3 2 PREPARATION: Prime or seal joint surfaces are recommended by the manufacturer. 2.2 FABRICATION: L_ o reinforcing bars or bundles of bars heavy rust and loose mill scale in accordance with SSPC SP-3 Comply with manufacturer's instructions Clean adjacent surfaces A. Fabricate steel door and frame units to be rigid, neat in A. Bockpr;me lumber with a single sealer coot of lacquer or b whatever means may be necessary to eliminate evidence of appearance, and free from defects, war or buckle. Where U E. Fine Aggregates. Natural washed hard sand varying from "Power Tool Cleaning" Remove oil, grease and similar Y Y Y PP p, t" varnish, complying with applicable finishing requirements m Division Spillage or other visually objectionable conditions. <r fine to particles passing a 3/8" screen, of which at led4t shall c.�ontominants ,n accordance with SSPC SP-1 "Solvent Cleaning". possible, fit and assemble units in manufacturer's plant. Shop �_ - 9 Sections of these specifications for primers and application. � W rn pass a 50 - mesh screen F Rough hardware: Furnish bent or otherwise custom prime all hollow metal doors and frames. co F. Water Clean, drinkable, and free from foreign matter. fabricated bolts, plates. anchors, hangers, dowels and other END OF SECTION 07270 - 0 0- 0 3.3 INSTALLATION: . � G. Moisture Barrier: 8 mils thick polyethylene sheet. miscellaneous steel and iron shapes as required for framing, PART 3 - EXECUTION: c� H. Pin new concrete slabs to existing with dowels. supporting or anchoring. A. Install the work plumb, level, true and straight with no distortions. Shim as required using concealed shims. Install to a m G. Miscellaneous Steel Trim: Provide shapes and sizes 3 ! HARDWARE PREPARATION:1. tt a; tolerance of 1/8 in 8'-O" for plumb and level, and with 1/16" cr, 2.2 DESIGN MIXES indicated for profiles shown. Unless otherwise indicated, fabricate A. Unless otherwise indicated, all doors and frames shall be C) A. Provide normal weight concrete for interior floor slab with units from structural steel shapes, plates, and steel bars, with maximum offset d flush adjoining surfaces and 1/8" maximum mortised and reinforced for hardware in the factory. 11 111, 4,000 psi ® 28 day compressive strength; W/C ratio: 0.44 continuously welded joints and smooth exposed edges. Use offsets in revealed adjoining surfaces. v maximum concealed field slices wherever possible. Provide cutouts, fittings, B. Scribe and cut to fit adjoining work, and refinish cut surfaces p P 9 3.2 INSTALLATION: rn or repair damages finish at cuts. DRAWN and anchorages as required for coordination of assembly and D g - A. Pre-fit doors at factory with clearance of 1/8" at vertical __.__�amP .____ _ __ ._____.____ cU PART 3 - EXECUTION installation with other work. Galvanize miscellaneous framing and C. Anchor to blocking or directly to substrate with countersunk, ry supports of exterior locations, and a� otherwise indicated. car) fasteners and blind nailing where possible. edges and at top, 1/8" :n 2" bevel at lock edge, bottom clearance: APPR. D Anchor to metal studs [where blocking does not exist) using 3/8" without threshold, 3/4" with threshold. ---------- - -- } D., 3.1 INSTALLATION: B. Install hollow metal doors and frames in accordance with DATE u A. Place reinforcement to obtain the minimum coverage for PART 3 - EXECUTION adhesive and pre-drilled countersunk trim-head sheet metal screws. 10/9 9$ 0 manufacturer's recommendations. Set frames accurate) in .�T�---" -` - -`-_--"" concrete protection. Arrange, space, and secure tie bars and bar Fill recess with wood putty to match surface finish of wood. Y SCALE C E. Install standing and running trim with minimum number of position, plumbed, aligned, and braced securely. Fit doors -D supports together with 16 gauge wire to hold reinforcement 3.1 PROTECTION: 9 9 N.T.S. joints possible, using full-length pieces to the greatest extent accurately within frames in accordance with clearances indicated accurately in position during concrete placement operations. Set A. Protect finishes of metalwork during construction period by j P 9 9 P 9 CAD FILE wire ties so twisted ends are away from exposed surfaces. use of temporary protective coverings Remove protective covering possible. Stagger joints in adjacent and related members. Cope at herein. Sand smooth all rust or damaged areas of prime coat and returns, miter at corners, and use scarf joints for end-to-end joints, apply touch-up coat of compatible primer. �H:`�FAPAGINO\HYANNISi T? B. Install welded wire fabric in as long lengths as practicable. at time of Substantial Completion. Restore finishes damaged during 1 JOB NO. �. Lap adjoining pieces at least une full mesh and lace splices with installation and construction period so that no evidence remains of to provide tight fitting joints with full surface contact throughout 98066 - _ - ,z length of joint. END OF SECTION 08100 -- ,l wire. Offset end lops ,n adjacent widths to prevent continuous laps corrected work. Return items that cannot be refinished in the field 9 1 SHEET �0 in either direction. to the shop; make required alterations and refinish entire unit or CD a C. Comply with ACI 304 "Recommended Practice for provide new units. ii Measuring, Mixing, Transporting, and Placing Concrete", and as z herein specified. END OF SECTION 05500 -. T _ SN� 1 c__ r� I . REVISIONS 7D)ATE F. Trim Accessories: Provide manufacturer's standard trim --- ------- T -___ ALUMINUM STOREFRONT SYSTEM SECTION 08410 GLASS AND GLAZING SECTION 08800 CERAMIC TILE SECTION 09300 PART 2 - PRaaucTs: 1.3 DELIVERY: [NO� �____---__-_._.-_.___.. accessories of types indicated for drywall work, formed of - A. Deliver materials to job site in original, new and unopened galvanized steel unless otherwise indicated, with either knurled and 2 1 MATERIALS packages and containers bearing manufacturer's name and label. _____+___ ---------•--- .. i PART 1 - GENERAL: PART 1 - GENERAL.: perforated or expanded flanges for nailing and beaded for PART 1 - GENERAL: t P g g A. Acoustical Panels. Refer to drawings for schedule far ceiling Store materials not in actual use in tightly covered containers. concealment of flanges in joint compound. Provide corner beads, materials and sizes. Maintain containers used in storage of paint in a clean condition, - -- ._ __- - __.___ 1.1 SECTION INCLUDES: 1.1 SECTION INCLUDES: L-type edge trim-beads, U-type edge trim-beads, special L-kerf-type 1.1 SECTION INCLUDES: B. K.itchen & Serving Areo Ceilings: Water Resistant Ceiling free of foreign materials and residue. Keep storage area neat and I A. Provide storefront framing as shown on drawings, as A. Provide lass and glazing as shown on the drawings, as edge term-beads. A. Provide the as shown on the drawings, as specified herein, Panels- 24 x 48" x 1 2" vinyl surfaced sum board 9 9 9 9 9 Pe / Y 9YP panels equal a�rderty. Remove rags and water doily. Take all precautions to _-----}._-._-_..__ ._ ___ ._ r ______ required herein, and as needed to meet the requirements of the G. Joint Compound: ASTM C 475 - for interior work provide q q specified herein, and as needed to meet the requirements of the and as needed to meet the requirements of the construction shown to Gypsum Ceiling Panels, as manufactured by USG, or Vinylrock, ensure that. workmen and work areas are adequately protected from ; construction shown in the contract documents construction single, multi-purpose grade, ready--mixed vinyl-type, with perforated in the contract documents. as manufactured by Copuul. fire hazards and health hazards resulting from handling, mixing and -______1.___-.--._.__- _ _ .i_-__---- type paper joint tape. 1 2 SUBMITTALS: C. Typical Ceiling Grid: Armstrong Prelude system 15/16" T- application of points. ' H. Gypsum Board Fasteners: Gypsum Board Screws: ASTM C 1.2 SUBMITTALS: 1.2 REFERENCES: 1002 A. Product Data: Submit manufacturer's technical information grid color=to match the A. Submit shopdrawing for fabrication and installation including r• 1.4 SITE CONDITIONS: 9 9 A. Glazing standards Comply with recommendations of Flat 1 Provide auxiliary materials for gypsum drywall work of the and installation instructions for materials required except bulk D. Aluminum Ceiling Grid (for use with water resistant ceiling elevations, detail sections of typical composite members, hardware Glass MarketingAssociation FGMA "Glazing Manual„ and t materials. include certifications and other data to show compliance panels). Armstrong Prelude system 15 16" T- rid color=white. A. Apply paints only when temperature of surfaces to be painted mounting heights, anchorages, reinforcement, expansion t ) g type and grade recommended by the manufacturer of gypsum P ) g y / g and surrounding air temperatures are within recommended range "Sealant Manual" except where more stringent requirements are boards. with these specifications. provisions, and glazing. 2.2 CEILING SUSPENSION MATFRIALS. permitted by the paint manufacturer's printed instructions. Do not indicated. Refer to those publications for definitions of glass and apply paint when relative humidity exceelk a85to damp or wet 1.3 SITE CONDITIONS 1.3 QUALITY ASSURANCE. A. General: Comply with ASTM C 635, as applicable to type of w r 'Z'" glazing terms not otherwise defined in this section or other PART 3 - EXECUTION surfaces. A. Take field measurements prior to preparation of shop A. Handle, store, mix and apply proprietary setting and grouting suspension system required for type of ceiling units indicated. r� > Q 1 referenced standards. Coordinate with other work supported b or penetrating through �-+ o drawings and fabrication, to ensure proper fitting of work. PP Y P• 9 9 T • O..,y z B. Safety Glazing Standards: Where safety glass is indicated materials in compliance with manufacturer's instructions 1.5 EXTRA MATERIALS: ceilings, including light fixtures, HVAC equipment, and partition ►�. �`� or required by authorities having jurisdiction, provide type of 3.1 INSTALLATION; B Provide materials obtained from one source for each type A Upon completion of this section, deliver to the owner extra W 1 _ FART 2 - PRODUCTS products indicated which comply with ANSI Z97.1 and testin system Of anyl. P P Y 9 A. Allowable Tolerance.,: 1/16" offsets between planes of board and color of tile, grout, and setting materials stack equal to one (1) gallon of each color, type and sheen of paint iL s B. Attachment Devices: Size for five (5) times design load a >�Ja V) requirements of 16 CFR Part 1201 for category II materials. faces, and 1 8" in 8'-0" for lamb, level, war and bow. C. Installer Qualifications- Engage on experienced installer who used in the work Lobel each color accordingly. 2 1 MATERIALS / P P• indicated in ASTM C 635, Table 1, Direct Hung. Q. Installation of Wall Partition Support Systems: install has successfully completed tile installations similar in material, r i9 � A. Drawings are based on one manufacturer's standard / PP Y G. Hanger Wires: Galvanized carbon steel, ASTM A 641 soft a I L. . 9 PART 2 - PRODUCTS: design, and extend to that indicated far project. PART 2 - PRODUCTS: supplementary framing, blocking and bracing to support fixtures, temper, pre-stretched, field--stress load cf at least three 3 times 'I _^ aluminum entrance and storefront system. Other standard systems y ( ) of a similar and equivalent nature will be acceptable when equipment, services, heavy trim, furnishings and similar work which design load, but not less than 12 gauge (0.106"). 2.1 GENERAL. w yi q P 2.1 MATERIALS: cannot be adequately supported on gypsum board alone. install 1.4 DELIVERY, STORAGE & HANDLING D. Ede Moldings: Manufacturer's recessed channel molding differences do not materially detract from design, concept or A. Float Plate Glass: Type 1, Quality 3, clear unless otherwise A. Deliver materials in original uno unopened containers with labels g g 9 A. Provide point products equal to materials listed in the paint ype Y q runner tracks at floors, ceiling and structural walls and columnsP for edges and penetrations of ceiling, with single flange of molding intended performances, as judged solely by the owner. intact and legible at time of use. Stare under conditions g P 9• g g g schedule included herein. Note that proprietary names used to ` indicated. where sum d wol► stud system abuts other work, except as g � .10 B. Typical Framing System: match existing or "Kawneer" Trifob a , c 9YP n` y � P exposed, baked enamel finish to match balance of grid. desighate materials are not intended to imply that products of <<- YR 9 Y 9 B. Tempered Glass Provide rime ass of color and type recommended b the manufacturer. Da not retain of the project site i"N P P g' YP- otherwise indicated. Space studs 16" o,c., except as otherwise y P j E. Exposed Suspension System Manufacturers standard named manufacturer are required to exclusion of equivalent �' „�N 11 451 (1" insulated glazing preferred for new construction) framing, indicated, which has been heat treated to strengthen glass in any material which has exceeded the shelf life recommended by its i indicated. exposed runners, cross-runners and accessories of types and products of other manufacturers. a o or equivalent extruded aluminum systems utilizing ASTM B-221 bending to not less than 4.5 times annealed strength manufacturer. U in g g C. Isolate studs from transfer of structural loading to system, profiles indicated, with exposed cross runners coped to lay flush •r..N aluminum for extrusions, and ASTM B-209 aluminum for sheet/plate C. Insulating Glass Unit: Sealed insulating units fabricated both horizontally and vertically, Provide slip or cushioned type joints with main runners. 2 2 MATERIALS. a i materials dual sealing system, spacer, desiccant, and corner reinforcement. 1.5 SITE CONDITIONS: F. Finish of Ex osed Members: Provide uniform factory-applied A. Provide rimers and undercoat points produced b the some �h to attain lateral support and avoid axial loading. Pprimers P P Y C. Fasteners: Aluminum, non-magnetic stainless steel, or other Glass thickness and heat strengthening to be. determined by D. At o enin s for doors, instal! double 2 eo in gouge studs at A. Maintain environmental conditions and protect work during finish on exposed surfaces of ceiling suspension system, including manufacturer as the finish coats Use only thinners approved by 010 materials warranted by manufacturer to be noncorrosive and manufacturer for wind loading conditions. Glass color to match P g ( ) g g and after installation in accordance with referenced standards and moldings, trim, and accessories. paint manufacturer, and use only with recommended limits compatible with aluminum components. Exposed fasteners shall existing adjacent materials, as applicable. all openings, screw attach web of back-to--back studs direct to jamb manufacturer's printed recommendations G. Finish: Manufacturer's baked enamel finish to match a of B. Match approved samples for color, texture, and coverage. =1 C4 - P p P g PP anchor clips nested between flange of stud, unless otherwise P type PP P g match finish of members and hardware being fastened. ?. Insulating glass warranty: 10 years. ceiling. Remove, refinish, or repaint work not ;n compliance with specified D. Concealed Flashing: ' Dead-soft stainless steel, 26 gauge A. Glazing Sealants and Components: indicated Frame openings other than door openings in some PART 2 - PRODUCTS: requirements , . „ manner as acquired for door openings; and install framing below minimum or extruded aluminum, 0.062 minimum as selected by 1. General: Provide color of exposed seolont/compound silts of openings to match framing required above door heads. r manufacturer for compatibility with other components. indicated or if not otherwise indicated, as selected by E. Installation of Wall Furring; Space wall furring members 24" 2.1 MATERIALS. PART 3 -- EXECUTION: PART 3 - EXECUTION: ...�.�_"") E Brackets and Reinforcements: Manufacturer's high-strength Architect from manufacturer's standard colors, or black if no A. Tie Materials: Refer to the drawings for the schedule of o.c. except as otherwise Indicated. Erect thermal insulation products, manufacturers and color of the materials. 3.1 EXAMINATION 3.1 EXAMINATION: aluminum units where feasible or non-magnetic stainless steel or color is so selected. „ P vertically and hold in place with 2-furring members spaced 16 a c A. Examine areas and conditions under which the work of this A Examine areas and conditions under which painting work isami 11 hot-dipped galvanized steel complying with ASTM A-386. 2. Two-part polysulf�de glazing sealant: Etostomer+c polysulfide - ,.Z except at exterior corners, securely attach narrow flanges of furring PART 3 - EXECUTION: section will be performed. Do not proceed if conditions exist that are to be applied and notify owner of conditions detrimental to proper ^•->:�2' .,1, F. Concrete/Masonry inserts: Cost-iron, malleable iron, or hot- sealant complying with FS TT-S-227 members to wall with concrete stud nails or Doer-drive fasteners �� dipped galvanized steel complying with ASTM A-386. P detrimental to proper and timely completion. Commencement of and timely completion of the work Starting of painting work will be aa, G. Bituminous Coatin s: Cold-a lied as halt mastic complyingPART 3 - EXECUTION spaced 16" o c. At exterior corners, attach wide flange of furring 3.1 INSTALLATION this work will be construed as acceptance of existing conditions or construed as acceptance of surfaces and conditions. � x 9 PP P members to wall with short flange extending beyond corner start A Tile Installation Standards: Comply with applicable prior work by others, and assumption of responsibility for �It', with SSPC-PS 12, compounded for 30-mil thickness per coat �•. p pp satisfactory installation 3 2 PREPARATION H. Compression Weather-Stripping: Manufacturer's standard 3.1 INSTALLATION: from this furring member with wide strip of insulation followed by requirements of the ANSI 108 series of the installation standards A. Prepare surfaces and apply coatings in strict accordance c� V ,r A. Watertight aria airtight installation of each lass product is furring member in ,he normal manner. At interior corners, space included under "American National Standard Specification for the , - p replaceable stripping of either molded neoprene gaskets complying 9 9 9 P P 3.2 PREPARATION: with the coating manufacturer's recommendations. , c• second member no more than 12" from corner and cut insulation to `� n �""..1. with ASTM D-2000 or molded PVC gaskets complying with ASTM required, except as otherwise shown. Each installation must tnstatlotion of Ceramic Tile" that apply to the type of setting and A. Coordination: Furnish layouts far inserts, clips, ar other B. Clean surfaces of dirt. rust, scale, grease, moisture, or other f. withstand normal temperature changes, wind loading, impact fit. Until sum board is installed, hold insulation in lace with 10" grouting materials and methods indicated. supports required to be installed by other trades for support of conditions otherwise detrimental to formation of a durable paint film. � !`, „ D- 7.287 P• 9 9• P 9YP F 9 q ,,sk.:,_.a_ loading (for operating sash and doors), without failure including loss staples fabricated from 18 gauge tie wire and inserted through slot B. Protective Coating- At installer's option, and where needed acoustical ceilings. Perform preparation and cleaning procedures in accordance with °r`t,'1,f P 9 ) 9 9' P 9 P P 9 2.2 PREFABRICATION: or breakage of glass, failure of sealant of gaskets to remain water in web of member, or by an equally acceptable method. to prevent adhesion or staining of exposed the surfaces by grout, B. Measure each ceiling area and establish layout of acoustical point manufacturer's printed instructions for each particular A. General: Complete fabrication, assembly, finishing, tight and airtight deterioration of glazing materials and other defects F Install supplementary framing, runners, furring, blocking and protect exposed surfaces of the against adherence of mortar and units to balance border widths at opposite edges of each ceiling. substrate condition P Y• 9• 9 9 9 9 P P 9a hardware application, and other work before shipment to project in the work bracing at opening and terminations in the work, and at locations rout b recootin them with a continuous film or tem ors Avoid use of less-than-half width units at borders, and comply with C. Remove hardware, accessories, ►otes, li htin fixtures, and .� PP P P j 9 Y P 9 temporary P 9 9 reflected eilin I n wherever i - site- Disassemble components aril as necessary for shipment and B. Clean glazing channel and other framing members to receive required to support fixtures, equipment, services, heavy trim, protective coating, taking care not to coat unexposed tie surfaces. ceiling plans spossible. similar items in place and not to be finish painted, or provide P Y rY P 9 9 9P 9• 9 P installation Comply with AWS recommendations to avoid glass, immediately before glazing Remove coatings which are not furnishings and similar work which cannot be adequately supported C. Floor the shall be thin-set in Portland cement mortar meeting surface-applied protection prior to surface preparation and painting 11 " � discoloration; grind exposed welds, smooth and restore mechanical firmly bonded to substrate. Remove lacquer from metal surfaces directly on gypsum board alone ANSI A 1 18 1. Use sanded cement grout with acrylic additive in 3.3 NVSTALLATION: operations. Remove, if necessary, for complete pointing of items finish Install reinforcing if required for performance requirements; where elostomeric sealants are used. G Install wali/partition boards vertically to avoid end-butt joints accordance with TCA Handbook Method No. F113. A. General: Install materials in accordance with manufacturer's and adjacent surfaces. Following completion of painting of each separate dissimilar metals with bituminous paint or other separator C. Comply with FGMA "Glazing Manual" and manufacturer's wherever possible. At stairwells and similar high walls, install D. Wall the shall be thin-set ;n organic adhesive meeting ANSI printed instructions and to comply with governing regulations, fire space or area, re-install removed items. which will prevent corrosion. Maintain accurate relation of lanes boards horizontally with end joints staggered over studs. A1361 T 11 Use non-sanded Portland cement rout with resistance rating requirements as indicated, and industry standards D. lean wood surfaces of dirt, oil, and other foreign P R instructions and recommendations. Use manufacturer's Yt� 9 applicable to work. substances with scrapers, mineral spirits, and sandpaper, as Q and angles with hairline fit at contacting members. Conceal recommended s seers, blocks, rimers, sealers, gaskets and H. install exposed gypsum board with face side out. Do not latex--acrylic odditive, per TCA Method No. W242. P P 9 B Arrange acoustical units and orient directionally-patterned required. Sand surfaces exposed to view smooth and dust off. fasteners wherever possible. install imperfect, damaged or damp boards. But boards together for E. Coin I with manufacturer's instructions for mixing and P accessories. Comply 9 units if an in manner shown b reflected ceilingIons Scrape and clean small, d seasoned knots and apply a thin coat B. Weather-Stripping. For exterior doors, provide compression D. Install lass with uniformity of pattern, draw, bow and roller a light contact at edges and ends with not more than 1/16" open installotion of proprietary materials. ( y) y P p '� PP Y 9 Y P P P Y C. Install the with pattern running in one direction. of white shellac or other recommended knot sealer before Z N weather-stripping against fixed stops, at other edges, provide sliding marks. Install sealants to provide complete wetting and bond and to space between boards. Do not force into place. F. Extend the work into recesses and under or behind D Install suspension systems to comply with ASTM C 636, with application of primer. After priming, fill holes and imperfections in -i weather-stripping retained in adjustable strip mortised into door create a substantial wash awe from lass Install pressurized I Locate either edge or end joints over supports except in equipment and fixtures to form a complete covering without finish surfaces with putty or plastic wood filler. Sand smooth when � � y 9 pP 9 hangers supported only from building structural members. Locate P Y edge tapes and gaskets to protrude slightly out of channel so as to horizontal applications or where intermediate supports or gypsum interruptions, except as otherwise shown Terminate work neatly at hangers near each end and spaced 4'-0" along each carrying dried , Z C. Storefront Framing System Fabrication. Provide inside- eliminate dirt and moisture pockets. board back-blocking ,is provided behind end joints. Position boards obstructions, edges and corners without disrupting pattern or joint channel or direct-hung runner, unless otherwise indicated, leveling E. Prime, stain, or seal wood to be painted immediately upon Z outside matched resilient flush-glazed system with provisions for E. Install insulating lass units to comply with recommendations so that both tapered edge joints abut and mill-cut or field-cut end alignments. delivery Prime edges, ends, faces, undersides, and backsides of Q • g g p y 9 to tolerance of 1 j$" in 12'-0" ry 9 glass replacement Shop-fabricate and pre-assemble frame by Sealed insulating Glass Manufacturers Associaton, except as joints abut. Do not place tapered edges against cut edges or ends. G. Accurately form intersections and returns. Perform cutting E. Secure wire hangers by looping and wire-tying, either directly wood, including cabinets, counters, cases, and paneling When a- W Q components where possible otherwise specifically indicated or recommended by glass and Stagger vertical joints over different studs on opposite sides of and drilling of the without marring visible surfaces. Carefully grind to structures or to inserts, eye-screws, or other devices which are transparent finish is required, backprime with spare varnish. Q iI"- >" D. Class 1 Color Anodized Finish: AA-M 1 2C22A42/A44 sealant manufacturers, partitions. cut edges of the abutting trim, finish or built-in items for straight secure and appropriate for substrate, and which will not deteriorate Backprime paneling an interior partitions where masonry, plaster, or Q_ = _ (Mechanical Finish. as fabricated, nonspecular; Chemical Finish;. J. Attach gypsum board to framing and blocking as required for aligned joints. Fit the closely to electrical outlets, piping, fixtures or fail with age or elevated temperatures. other wet wall construction occurs on backside. Seal tops, bottoms, etched, medium matte, Anodic Coating; Class t Architectural, film 3.2 PROTECTION: additional support at openings and cutouts. Form control joints and and other penetrations so that plotes, colors, or covers overlap the F Install edge moldings of type indicated at perimeter of and cutouts of unprimed wood doors with a heavy coat of varnish or - thicker than 0.7 mil with integral color or electrolytically deposited A. Protect exterior lass from breoka a immediate! upon expansion joints with space between edges of boards, prepare to H. Jointing Pattern: Unless otherwise shown, la the in rid acoustical ceiling area and at locations where necessary to conceal sealer immediately upon delivery. 9 Y# Y P 9 9 Y P g Y g F. Clean, non olvanized ferrous-metal surfaces that have not - color complyingwith AAMA 606.1 or AAMA 608 1 -- Color to match installation, by use of crossed streamers attached to framing and receive trim accessories. Cover both faces of steel stud partition, pattern. Align joints when adjoining tiles on floor, base, walls, and edges of acoustical units g • been shop coated, remove oil, grease, dirt, loose mill scats, and existing storefront materials (if applicable), or if not existing, provide held away from glass. Do not apply markers to surface of glass framing with gypsum board in concealed spaces (above ceilings, trim are some size. Layout the work and center the fields in both G. Re-attach moldings to substrate at levels not over 16" o c, other foreign substances. Use solvent or mechanical cleaning Remove nonpermanent labels and clean surfaces. Cure sealants etc ) except in chase walls which are properly braced internally. directions in each space or on each wall area Adjust. to minimize and not more than 3" from ends, leveling with ceiling suspension methods that comply with recommendations of the Steel Structure- 40 p "bronze" color. P Y - for high early strength and durability. K. Isolate perimeter of non-load-bearing drywall partitions at tile cutting. Provide uniform joint widths, unless otherwise shown. system to tolerance of 1/8" to 12'--O" Miter corners accurately and painting Council PART 3 - EXECUTION: structural abutments. Provide 1/4" to 1/2" space and trim edge with connect securely. G. Touch up shop-applied prime coats that have been c7 3.2 CLEANING AND PROTECTION H. Install acoustical panels in coordination with suspension damaged. 3 3 REPAIR- J-type semi-finishing edge trim. Seal joints with acoustical sealant. g d. Wire brush, clean with solvents recommended by the o A. Remove and replace damn ed lass and glazing. Wash and A. on completion of placement and grouting, clean all system, with edges concealed by support of suspension members point manufacturer, and touch u with the same rimer as the shop 3.1 INSTALLATION: P 9 9 9 9• Do not fasten drywall directly to stud system runner tracks. UP P P 9 9• P P P P polish glass on both faces not more than 4 days prior to date L. Space fasteners in gypsum boards in accordance with ceramic the surfaces so they are free of foreign matter. Scribe and cut panels to fit accurately at borders and at coat. A Comply with manufacturer's instructions and penetrations recommendations for installation of aluminum entrances and scheduled for inspections intended to establish date of substantial referenced standards and manufacturer's recommendations. B Unglazed tile may be cleaned with acid solutions only when H. Materials Preparation. Carefully mix and prepare paint completion Comply with glass product manufacturer's permitted by the and grout manufacturer's printed instructions, but 3.4 ADJUSTMENT & CLEANING materials in accordance with manufacturer's directions. Maintain storefronts. containers used in mixing and application of point in a clean B. Set units plumb, level, and true to line, without warp or rack recommendations for final cleaning. 3.3 GYPSUM DRYWALL APPLICATION METHODS: not sooner than 14 days after installation. Protect metal surfaces, A. Adjust and clean ex osed surfaces of acoustical ceilings,s, g P of framing members, doors, or panels Anchor securely in place, A. Single-loyer application: install exposed gypsum board cast iron and vitreous plumbing fixtures from effects of acid including trim, edge moldings, and suspension members; comply condition, free of foreign materials and residue. Stir material before END OF SECTION 08800 B. On cleaning, Flush surface with clean water before and after cleaning. ,r application to produce a mixture of uniform density, stir as required separating aluminum aria other corrodible metal surfaces from partii:ons/walls apply gypsum board vertically (parallel). g 9 with manufacturer's instructions for cleaning aria touch-up of minor during application. Do not stir surface film into material. Remove or sources of corrosion of electrolytic action at points of contact with �� unless otherwise indicated, and provide sheet lengths which will C. Finished Tile Work: leave finished installation clean and finish damage Remove and replace work which cannot be film and, if necessary, strain material before using. Use only GYPSUM DRYWALL SECTION 094 �0 minimize end joints free f cracked, chipped, broken unbonded, or otherwise defective successful! cleaned and repaired to permanently eliminate thinners approved by the paint monufocturer, and only within other materials. j Y P P Y C. Drill and to frames and doors and apply surface-mounted C. On z-furring members, apply sum board verticall • the work, evidence of damage. p pp y 9 PP Y 9YP Y recommended limits. hardware items, complying with hardware manufacturer's PART 1 - GENERAL. (parallel) with no end-joints Locate edge joints over furring D. Protection: When recommended by the manufacturer, apply ( n instructions and template requirements. Use concealed fasteners members. a protective coat of neutral protective cleaner to completed the walls END OF SECTION 09510 3 3 APPLICATION: �+ ` wherever possible. 1.1 SECTION INCLUDES: D. Direct-Bonding to Substrate: Where gypsum board is and floors Protect installed tile work with Kraft paper or other A. Apply paint in accordance with manufacturer's directions Z D. Set sill members in bed of sealant as indicated, or with oint A. Provide screw-type heavy covering during construction period to prevent damage and PAINTING C Use a iicators and techniques best suited for substrate and type of j yp gypsum drywall as shown on the indicated to be directly adhered to a substrate (other than studs, PA NTlN SE TION 09900 PP q YR o wear. material being applied. Do not point over dirt, rust, scale, rease, fillers or gaskets as indicated to provide weothertight construction. drawings, as specified herein, and as needed to meet the joints, furring members or base toyer of gypsum board), comply with g PP pa g Comply with requirements of Division 7 for sealants, fillers, and requirements of the construction shown in the contract documents. E. Prohibit foot and wheel traffic from using tiled floors for at moisture, scuffed surfaces, or conditions detrimental to formation of P Y q q gypsum board manufacturer's recommendations, and temporarily least three (3) days after grouting is completed PART 1 - GENERAL: o durable paint film. F--- gaskets. the work includes, but is not necessarily limited to the following brace or fasten gypsum board anti{ tastening adhesive has set. F. Before final inspection, remove protective coverings and B. Scheduling: Apply first--coat material to surfaces that have 1. Gypsum drywall including screw-type support system. E. Installation of Drywall Trim Accessories. Where feasible, use rinse neutral cleaner from the surfaces. 1,1 SUMMARY: been cleaned, pre-treated, or otherwise prepared for painting as 3.2 CLEANING: 2 Drywall finishing (joint tape and compound treatment) the some fasteners to anchor trim accessory flanges as required to A Surface preparation and painting or finishing of interior soon as practicable after preparation and before subsequent A. Clean completed system inside and out, promptly after fasten gypsum board to the supports. Otherwise. fasten flanges by ENG OF SECTION OF1300 exposed to view, throughout the project and in accordance with surface deterioration. Allow sufficient time between successive erection and installation of glass and sealants. Remove excess 1.4 REFERENCES: nailing in accordance with manufacturer's instructions and ACOUSTICAL CEILINGS SECTION 0y51 requirements herein. Except where a natural finish or a material is coatings to permit proper drying. Do not re-coat until paint has W V glazing and joint sealants, dirt, and other substances from aluminum A. Gypsum Board Standards: GA-216 by Gypsum Association. recommendations. Instal! metal corner beads at external corners of specifically noted as a surface not to be pointed, point all exposed dried to where it feels firm, does not deform or feel sticky under __J surfaces drywall work. moderate thumb pressure, and application of another coat of paint Z rY surfaces whether or not painting ;s designated �n the drawings. 1.3 REGULATORY REQUIREMENT- F. Install edge trim whenever edge of sum board would PART 1 GENERAL does not cause lifting or loss of adhesion of the undercoat. W END OF SECTION 08410 A. Fire-Resistance Ratings. Where gum drywall systems .g g gyp Where items or surfaces are not specifically mentioned, paint the O 9 9YP- rY Y otherwise be exposed or semi-exposed. Provide type with face same as similar adjacent materials or areas. C. Apply paint to completely cover previously painted surfaces, with fire resistance ratings are indicated or are required to comply flan a to receive Dint compound.ound. Install L-t e trim whore work ;s 1.1 SECTION INCLUDES to provide an opaque, smooth surface of uniform finish, color, FINISH HARDWARE SECTION 08710 9 1 P YP B. The work of this section includes, but is not necessarily appearance, and coverage. Cloudiness, spotting, holida s, lopQ.-.1 y ��, with governing regulations, provide materials and installations tightly abutted to other work, and install special kerf--t a where A- Provide acoustical ceilings as shown on the drawings, as PP g y L.L. identical with applicable assemblies which hove been tested and g Y P YP9 limited to painting or finishing of the fallowing items; marks, brush marks, runs, sags, ropiness or other surface PP other work is kerfed to receive long leg of L--type trim. Install U-type specified herein, and as needed to meet the requirements of the 1. Hollow metal doors and frames- not be acceptable.imperfections will (""0 1 Q PART 1 - GENERAL listed by recognized authorities including UL. where edge is exposed, reveoled, gasketed, or sealant-filled construction shown in the contract documents. 2 Alt interior drywall surfaces not finished iD. The number ll coats and film thickness required is the some PART ? - PRODUCTS: (including expansion joints) otherwise regardless of the application method. Do not apply succeeding U 1 'I SECTION INCLUDES: G. !nstallation of Drywall Finishing: Apply treatment at gypsum 1.2 QUALITY ASSURANCE: 3. Exposed portions of fixture trims and coats until the previous coat has cured as recommended by the r ct, A. Provide finish hardware throughout the work as indicated in board joints (both directions), flanges of trim accessories, A. Installer: Firm with no less than three (3) years of successful mechanical grills. manufacturer. Sand between applications where sanding is W 7 the drawings, as specified herein and as required for a complete 2.1 MATERIALS: penetrations, fasteners heads, surface defects, and elsewhere as experience in installation of acoustical ceilings similar to 4. Partially concealed, interior portions of ducts, required to produce an even smooth surface in accordance with the W cu installation. A. Metal Support Standards: ASTM C-754. q prepare p j q j P 9 g q �,., -" .-, required to re pre work for decoration. Prefill open Dints and requirements for This project aria which is acceptable to visible through registers or rills. manufacturer's directions. f- 1.2 PERFORMANCE REQUIREMENTS B. Studs. ASTM C 645; 20 gauge unless otherwise noted. �„� -� rounded or beveled edges using type of compound recommended manufacturer of acoustical units, as shown by current written 5. Interior finish carpentry E. Apply additional paint coats when undercoats, stains, or Cr A. Fire-Rated Openings: Comply with NFPA Standard No. 80 1. Depth of Section: 3-5/8" or as noted. by manufacturer. Apply joint tape at joints between gypsum boards, statement from manufacturer. A. Pointing Not Required Unless otherwise indicated, pointing other conditions show through final coat of point, until point film is of L. Z W CD and local codes for installation of hardware in fire-rated assemblies. 2. Runners: Match studs: type recommended by stud except where a trim accessory is indicated. ! joint compound 1.3 DELIVERY, STORAGE & HANDLING: is not required on plastic, lominate, re-finished sheet metal, uniform finish, color, and appearance Give special attention to -_ P rY Apply 1 P 4 P P Q Provide only hardware which has been tested and listed by UL or manufacture for floor and ceiling support of .studs, and for A. Deliver materials in on mot unopened containers and store plumbing fixtures, electrical equipment (excluding exposed insure that surfaces, including edges, corners, crevices, and i_ 0- in three (3) coats (not. including prefill of openings in base), and 9 `-' FM in compliance with requirements of door and door frame labels vertical abutment of drywall work at other work. them in a full enclosed space where the will be protected against exposed fasteners receive a dry film thickness equivalent to that of c �r sand between last two (2) coats and after last coat At water- Y P Y P 9 distribution cabinets) electrical devices, or food service equipment. flat surfaces. V d A Stud System Accessories: Provide stud manufacturer's f damn a from moisture, direct sunk lit, surface contamination or 01 Cn resistant gypsum board base for ceramic tile, tape and inish joints g 9 Pointing is not required on surfaces such as walls or ceilings in F- Paint surfaces behind movable equipment and furniture cn PART 2 - PRODUCTS: standard clips, shoes, ties, reinforcements, fasteners and other other causes. with two (2) coats water-resistant joint material, concealed or inaccessible areas. Metal surfaces of anodized same as similar exposed surfaces, Paint surfaces behind 2.1 MATERIALS. accessories as needed for a complete stud system. p er H. Partial Finishing- Omit third coat if specified) and sanding aluminum, stainless steel, chromium plate and similar finished permanently fired equipment or furniture with rime coat only before A. Fasteners Provide necessary screws, bolts and other B. Furrin Members. ASTM C 645; 25 gouge a hat-sho ed. 9 ( P ) g P YP Y u-: Y 9 g 9 P 1 4 EXTRA MATERIALS materials will n<:�i require finish pointing, except as otherwise final installation of equipment. on concealed drywall work which is indicated for drywall finishing or a P 9• P iri fasteners of suitable size and type to anchor hardware in position C. Z-Furring Members: Manufacturer's standard screw-type A. Maintenance Stock At time o. completing installation, indicated in the finish hardware schedule. Do not Dint over code- G. Paint interior surfaces of ducts, where visible through cri which requires finishing to achieve fire resistance rating, sound P 9 for long life under hard use. Provide concealed fasteners for zee-shaped furring members; of not thinner than 26 gauge deliver stock of maintenance material to owner. Furnish full size re uired labels orequipment identification labels. registers or rills with a flat, nons ecular black point. Paint back DRAWN cv - - rating or to act as air or smoke barrier. Refer to sections on paint, q9 grills P P am hardware units which are exposed when door is closed. galvanized steel, ASTM A 525, G90; of depth indicated; designed units matching units installed, packaged with protective covering for sides of access panels and removable or hinged covers to match coating, and wall-coverings in Division 9 for decorative finishes to P 9 -- - ---p cu for mechanical attachment of insulation boards or blankets to storage, and identified with appropriate labels. Furnish amount 1.2 QUALITY ASSURANCE: exposed surfaces P,PPR be applied to drywall work P PART 3 - EXECUTION: monolithic concrete and masonry walls. Provide fasteners a. type equal to 2 0% of each type of the total acoustical panels installed. A. Use only skilled g pp y g paint. H. Minimum Coating Thickness: Apply materials at not less ------------ --- ------ ------ .,.., z y painters for mixing and a I in U 1 PREPARATION: and size recommend by manufacturer. c 3.4 PROTECTION. Quality workmanship is required. In the acceptance or rejection of than the manufacturer's recommended spreading rote. Provide a ',ATE 10 2 98 A. Remove existing deadbolts with keyed cylinder locks inside D Exposed Wallboard: Type X (fire resistant) with tapered long total dry film thickness of the entire system as recommended by the -------� -_. _ __ _._-.____--_-- c A. Installer shall advise contractor- of required procedures far finish painting, no allowance will be made for the painters' lack of C. occupied space. Replace with new deadbolt with removable core edges, 5/8" thickness, except where other indicated in maximum manufacturer. .,:;ALE protecting gypsum drywall work from damage and deterioration skill or inadequate lighting during painting operations. N.T.S. and disengaging hardware; reconfigure existing unit. length available which will minimize end joints. I. Prime Coots: Before application of finish coats, apply a __ ___-�-.__ during remainder of construction period. B. Provide best quality grade of various types of coatings as 3.2 INSTALLATION. E. Water-resistant Type: Provide behind all ceramic the work prime coat of material as recommended by the manufacturer to CAD FILE A. Install hardware items at heights as recommended by the regularly manufactured by acceptable paint materials' material that is required to be painted or finished and has not been. H:\PAPAGINO\HYANNiS and where otherwise indicated, 5/8" thick water-resistant Type X. END OF SECTION 09250 manufacturers. Materials not dis 1a rn manufacturer's rime coated b others Re-coat rimed and seated surfaces where ._1.__.___._____._______. SOB NO, ._----- -.._-__----- z Door and Hardware Institute, except as specifically required to Provide Durarock (or equal) to 18" above finish floor on all wet walls identification as a standard, bestA ode product will not be evidence of suction sots or unsealed areas in first coat a rn comply with local codes. Install hardware ;n compliance with the y P p ppears r 98066 in kitchen and restrooms. acceptable assure a finish coat with no burn through or other defects due to ____�'__- --. -. - _ 10 manufacturers instructions and recommendations. Set units level, SHEET coplumb and true. Consult with owner as to keying instructions. insufficient sealing. Adjust and check operation of every unit. Replace units which J Pigmented (Opaque) Finishes: Completely cover to provide cannot be adjusted to operate freely and smoothly. an opaque, smooth surface of uniform finish, color, appearance, and coverage Cloudiness, spotting, holidays, lops brush marks, i END OF SECTION 08710 runs, sags, ropiness: or other surface imperfections will not be z - acceptable. '�"""' Cr K. Transparent (Clear) finishes: Use multiple coats to produce SN 2 c a glass-smooth surface film of even luster. Provide a finish free of laps, cloudiness, color irregularity, runs, brush marks, orange peel, nail holes, or other surface imperfections. m a. is E. Prime, stain, or seal wood to be painted immediately upon NO- ' REVISIONS DATE FART 2 - PRODUCTS: PART 3 - EXECUTION: PART 2 - PRODUCTS: ______..__-__ 3. -7 4 FIELDQUALITY CONTROL delivery. Prime edges, ends, faces, undersides, and backsides of A. The owner reserves the right to engage the services of on wood, including cabinets, counters, cases, and paneling. When 2 1 PARTITIONS. independent testing laboratory to sample the paint materials being transparent finish is required, backprime with spore varnish. _ 2.1 SECTION INCLUDES: ___.____._1______.___ .__- A. Toilet compartments shall be San m 3.1 EXAMINATION: A. Materials shall be fabricated to the configurations indicated use Samples of material delivered to the project may be taken. Backprirr�e paneling on interior partitions where masonry, plaster, or P y eta! "Normandie g identified, sealed, and certified in the presence of the contractor. other wet wall construction occurs on backside. Seal tops, bottoms, (BEIGE) Knickerbocker New York", Global "Regal", or approved A. Examine areas and conditions in which wail surface on the drawings and pursuant to field measurements of products The testing laboratory will perform appropriate tests as required by and cutouts of unprimed wood doors with a heavy coot of varnish or equal. Floor supported, overhead braced, metal toilet partition. protection components and wall protection systems will be installed. having gauge, finish, and detail indicated thereon or herein. ,T _. . the owner. If test results show material being used does not comply sealer immediately upon delivery. B. Partitions and doors shall be 1" thick, flush formed, of two Complete all finishing operations, including painting before _ _ - with specified requirements, the contractor may be directed to stop F. Clean, nongalvanized ferrous-metal surfaces that have not sheets of #22 Gouge (Min) of galvanized-bonder;zed steel cemeted beginning installation of wall surface protection system materials. 2.2 MATER1Al.S: pointing, remove noncomplying paint, pay for testing, repaint been shop coated, remove oil, grease, dirt, loose mill scale, and under pressure to corrugated core. Edges shall be interlocked with A. Condiment Stand Refer to the Millwork Drawings for details --. --- -I surfaces coated with rejected paint, and remove rejected point from other foreign substances. Use solvent or mechanical cleaning g #20 Gauge binding strips welded at corners. 3.2 PREPARATION: and requirements. Materials used in the fabrication thereof shall A. Preparation: Prior to installation, clean substrate to remove comply with all applicable specifications of the materials in Section --- ---------- -_ _ previously painted surfaces if, upon repainting with specified paint, methods that comply with recommendations of the Steel Structures C. Pilasters shall be 1 1/4 thick, flush formed, of two sheets of __,�__the two coats are noncom atible. dust, debris, and loose particles. 06100. P painting Council. #20 Gouge steel, and constructed as specified for doors and B. Stainless Steel Dividers and Vegetable Sink: Shall be G. Touch up shop-applied prime coats that have been partitions. Pilasters shall be secured by integral "U" channel with custom fabricated in accordance with details indicated on the 3.5 CLEANING: damaged. Wire brush, clean with solvents recommended by the galvanized bolts to floor construction. Pilasters trim shall be 3.3 INSTALLATION A. During the progress of the work, remove from site discarded point manufacturer, and touch up with the some primer as the she Fabrication Drawings. Steel shall be a minimum of 14 gouge paint materials, rubbish, cons and rags at end of each work day. coat, P A. install wall surface protection units plumb, level, and true to # 9 9 adjustable type. stainless steel, 3" high with rounded corners and no stainless. Type screws or bolts visible. line without distortions. Do not use materials with chips, cracks, YP 18-8. Sink shall have a 1 1/4" rolled edge on front Upon completion of painting work, clean window glass and other H. Materials Preparation: Carefully mix and prepare point D. Reinforce doors and p voids, stains, or other defects that might be visible in the finished and ends, a 9 1/2" high continuous bocksplash with a 2" turn-back pain spattered surfaces. Remove spattered paint or otherwise materiels in accordance with manufacturer's directions. Maintain pilasters to receive horns. and at 45 de gees. Drainboard shall be integrally welded r damaged finish surfaces Touchup and restore oN damaged or containers used in mixingand application of remforr_e pilasters to receive dividing partitions. Ail reinforcing shall work. Install retainers, mounting brackets, and other accessories in g g y e ded to sink, and w >-I r• c�m ps point in a clean be concealed, strict accordance with the manufacturer's instructions pitched to basin. Sink shall be mounted on a 1 5,/8" diameter MN defaced painted surfaces after completion of work of other trades, condition. free of foreign materials and residua Stir material before E. Headra;l shall securely brace pilasters with continuous B. Installation of FRP Paneling. galvanized steel legs, supported by stainless steel gussets at sink. 4 �application to produce a mixture of uniform density. stir as required anodized extruded aluminum rail of anti-trip design exter�drng over 1 Pre arotipn: Acclimate04base. Provide legs with adjustable stainless steel feet. ;> � 3.6 PROTECTION during application. Do not stir surface film into material Remove P panels in temperature A- Protect work of other trades, whether to be painted or not, film and, if necessary, the full length of the installation and over end compartment and humidityC. Automatic Fire Protection System For Cooking Exhaust a .,D conditions approximating project Hood: System shall be dry chemical and shall protect all cooking c0 ry, strain material before using. Use only partitions. Cap exposed ends. PP y those of the ro�ect against damage by painting. Correct damage by cleaning, repairing thinners approved by the point manufacturer, and only within site for not less than 24 hours before application. Lay panels appliances and kitchen exhaust ductwork as required by state 06 � or replacing and repainting as acceptable to owner. Provide "wet recommended limits. flat Do not stock on fresh concrete floors or other surfaces and/or municipal codes. The system shall protect and automatically lu m point" signs to protect newly pointed finishes. Remove temporary 2.2 FASTENERS: protective wrappings provided b others for P ry P y jack-leveling screw, for that emit moisture. Walls must be dry and free from dirt, shut off fuel to all equipment, and shall include electrical shunt-trip A. Secure ilasters to the floor bPP 9 P e protection of their work y dust, and grease. Remove switchplates, wall lates, and _ after completion of painting operations. At completion of 3.3 APPLICATION: mechanics! load, bearing, and vertical adjustments. P device to shut off exhaust. A readily accessible means to manuaNy �-'iconstruction activities of other trades, touch up and restore A. APPIy point in accordance with manufacturer's directions. B. Brar_kets for connections to walls, panels, and pilasters shall surface mounted fixtures in areas where panels ore to be activate the system shall be furnished and installed in a location W DW damaged or defaced Use applicators and techniques best suited for substrate and type of be either anodized extruded aluminum, or chromium plated, die-cast applied " adjacent to the cooking battery. Ali piping, hangers, accessories rJ P g painted surfaces. PP q I material being applied Do not paint ever dirt, rust, scale, grease, zinc alloy, stirrup brackets. 2. Panel Fitting: Position panels with 1/4 gap at shall be concealed from the customers view. Incidental piping or -0 (_ i .0 END OF SECTION 0900 moisture, scuffed surfacesIV or conditions detrimental to formation of C. Exposed fasteners shall be chromeplated, one-way, vandol- ceiling division bar of molding to allow for normal expansion y public view shoes be rii IV accessories that may be necessay{ installed in o a durable point film, proof, screws and bolts. g { / qop around pipes, of chrome or stainless steel finish. System shall be Model #R101, 9 o P and contraction. Allow not less than 1 8" no B. Scheduling Apply first-coat material to surfaces that have electrical fittings, and other projections. Use carbide-tipped with #20 cabinet, as manufactured by Ansul, or approved equal. PAINTING SECTION 09900 been cleaned, pre-treoted, or otherwise prepared for pointingas 2.3 HARDWARE: panel before D. Fasteners. Furnish all fasteners required for the assembly soon as practicable after power saws to cut panels. Prefit each p preparation and before subsequent A Hardware, except working ports of gravity hinges, shall be installing and installation of materials of this section and in accordance with �{ PART 1 - GENERAL: surface deterioration. Allow sufficient time between successive heavy brass, polished chromium plated, over nickel plate. Hinges 3. install panels by using Marlite #C-375 adhesive the drawings and approved shop drawings. i p coatings to permit proper drying. Do not re-coat until paint has shall be gravity type with concealed stainless steel ball-bearing E Other materials. All other materials if not specifically f rollers in self-lubricating oil bronze bearings Hinges shall be (or Marlite #C-5y1 adhesive where solvent vapors cannot be 1 1 SUMMARY- dried to where ;t feels firm, does not deform or eel sticky under g 9 9 furnished by the owner, shod be furnished as required, and shall be moderate thumb pressure, and application of another coot of point adjustable for holding door ;n open or portly open position when not adequately ventilated) to back of panels for 100% coverage first-quality designed or otherwise fabricated with referenced A. Surface preparation and pointing or finishing of interior does not cause lifting or loss of adhesion of the undercoat. latched. with a notched trowel. Before adhesive skins over set standards for their intended use and selected by the general exposed to view, throughout the project and in accordance with C. Apply point io completely cover previously pointed surfaces, B, Each door shall hove one coat hook with rubber tipped panels in position and press against wall. Pull entire panel contractor with the approval of the architect. requirements herein. Except where a natural finish or a material is tc provide an opaque, smooth surface of uniform finish, color, bumper, one slide-bar latch, and one combination door stop and back away from wolf 8" to 10" to flash off solvents. Press ....�.� specifically noted as a surface not to be painted, point all exposed latch tree er PART 3 -- EXECUTION: r P P F appearance, and coverage. Cloudiness, spotting, holidays, lap P bock in place. Apply adequate pressure to make full contact surfaces whether or not painting is designated in the drawings marks, brush marks, runs, sags, ropiness or other surface between panel and wall 3 1 INSTALLATION Where items or surfaces are not specifically mentioned, paint the imperfections will not be acceptable. 2.4 FINISH: 4. Panel Moldings Provide one- iece matchin some as similar adjacent materialsp g or areas D. The number of coats and film thickness required is the same A. All exposed surfaces, other than hardware and pilaster trim A. Install equipment items in accordance with the approved B. The work of this section includes, but is not necessarily regardless of the application method. Do not apply succeeding shall be cleaned and given one coat of rust-resisting primer baked- trim and panel moldings at all joints between panels, and at PP � r top and bottom edges of panels Install moldings with shop drawings and cuts, using equipment designed for each , �� limited to painting or finishing of the following items: coats until the previous coat has cured as recommended b the on and followed by two coats of high-grade synthetic enamel to g � g y produce a semi-gloss finish of the color selected. Each coat continuous bead of silicone sealant during installation of particular operation. Make m mechanical and electrical `(��' rI `W Al*-`^' Grp' manufacturer. Sand between applications where sanding s connections as required to make each respective item completely v " r'; d 1. Hollow metal doors and frames. separately baked on panels Seal joints between moldings and between molding operational, and comply with all applicable mechanical and electrical ? ,�-,t� 2 All interior drywall surfaces not finished required to produce on even smooth surface in accordance with the otherwise. manufacturer's directions and adjacent finish material. Remove excess sealant standards established in the reiated sections. Upon completion of i:.,.'wr 3. Ex osed E. A 1 additional 2.4 SCREENS: immediately. P P Ta < p portions of fixture trims and Apply paint coots when undercoats, stains, or A. Screens shall be b the same manufacturer as the toilet installation and prior to final inspection by the architect, remove all W. z y pockings and clean all parts and surfaces thoroughly. AI,� a,f. I" mechanical grills. other conditions show through final coat of paint, until paint film is of comportments with similar construction as doors and partitions. 3.4 CLEANING: B. Fabrication and Installation of Wood and Plastic Laminate - -I ��` 4 Partially concealed, interior portions of ducts, uniform finish, color, and appearance. Give special attention to insure that surfaces, including edges, corners, crevices, and Screens shall be manufacturers standard wall--hung design, A immediately upon completion of installation, clean surface In '�, -_ visible through registers or grills. 9 9 9 P general, fabricate all such items in accordance with the drawings �� '� -6- 5 Interior finish carpentry. exposed fasteners receive a dry film thickness equivalent to that of matching toilet compartment finish. With leg to floor. protection units and accessories using a standard ammonia based and the approved shop drawings. Refer to Section 06100 for �� ; flat surfaces household cleaning agent. Clean metal components in accordance applicable standards and material specifications. A. Painting Not Required Unless otherwise indicated, pointing F. Point surfaces behind movable equipment and furniture PART 3 - EXECUTION: with the manufacturer's recommendations C. Fabrication and installation of Stainless Steel Align all parts is not required on plastic, laminate, pre-finished sheet metal, some as similar exposed surfaces. Paint surfaces behind B. Remove surplus materials, rubbish, and debris resulting from for true, tight fit with sharp angles, correct offsets, and straight lines, 11 plumbing fixtures, electrical equipment (excluding exposed permanently fixed equipment or furniture with prime coat only before 3.1 INSTALLATION. installation upon completion of work and leave areas of installation secure while welding to prevent distortion, and weld in accordance distribution cabinet(s) electrical devices, or food service equipment. final installation of equipment A. Erect compartments rigid, straight, plumb, and level in in neat, clean condition. with the approved shop drawings and applicable industry standards, Painting is not required on surfaces such as walls or ceilings in G. Paint interior surfaces of ducts, where visible through accordance with approved shop drawings. Secure partitions to C. Remove excess adhesive and sealant while it is still wet insuring proper penetration and completeness in all respects. Grind concealed or inaccessible areas. Metal surfaces of anodized registers or grills with a flat, nonspecular black paint. Point back walls with not less than two stirrups located near the top and all welds, burrs, drill and punch holes, cutouts and other machined aluminum, stainless steel, chromium plate and similar finished sides of access panels and removable or hinged covers to match bottom. Each stirrup shall be through-bolted to the partition and Replace removed plate and fixtures Remove surplus materials and features smooth and polish to original finish. debris resulting from pane! installation upon completion of work,materials will not require finish exposed surfaces. bolted to the wall with two bolts in expansion shields. Kea wall D. Miscellaneous Prior to final payment, the contractor shoes q painting, except of otherwise ends � f the partition P and leave areas of installation in clean condition V) Q indicated in the finish hardware schedule. Do not paint over code- H. Minimum Coating Thickness. Apply materials at not less p panels away from the wall by approximately obtain certificate of compliance from all jurisdictional authorities required labels or equipment identification labels. than the manufacturer's recommended spreading rate Provide a 3y 4". END OF SECTION 10265 including, but not limited to, the Fire Department and State Health -0 M total dry film thickness of the entire system as recommended by the B. Anchor pilasters to the floor in strict accordance with the Dept code authorities and local building department for all fire 1.2 QUALITY ASSURANCE manufacturer. manufacturer's recommendations and as shown on the drawings. protection equipment furnished and installed under this section. Z CAI A. Use onlyskilled L Prime Coats. Before application of finish coats, apply a Anchors shall be accessible for leveling and tightening and shall be TOILET ACCESSORIES SECTION 10800 h/) �_ painters for mixing and applying paint. prime coat of material as recommended by the manufacturer to concealed by pilaster trim. FURNITURE, FIXTURES, AND ACCESSORIES: SECTION 12300 Quality workmanship is required. In the acceptance or rejection of material that is required to be pointed or finished and has not been C. All evidence of drilling, cutting, and fitting of wall and floor , Z finish pointing, no allowance will be made for the pointers' lack of prime coated by others. Re-coat primed and sealed surfaces where finish shall be concealed in finished work. Clearance at vertical PART 1 - GENERAL: Q Z: skill or inadequate lighting during pointing operations. evidence of suction spots or unsealed areas in first coat appears to edge of doors uniform from top to bottom and shall not exceed 1/4" PART 1 - GENERAL Z B. Provide best quality grade of various types of coatings as assure a finish coot with no burn through or other defects due to Carefully adjust hardware and leave in perfect working order. 1 i SECTION INCLUDES 1.1 SECTION INCLUDES 0- il <f regularly manufactured by acceptable point materials' insufficient sealing. Finish surfaces shall be cleaned and left free from imperfections. A. Provide toilet accessories as indicated in the drawings in all (L � _ manufacturers Materials not displaying manufacturer's J. Pigmented (Opaque) Finishes: Completely cover to provide 9 A. The work of this section includes all labor, materials, identification as a standard, best-grade product will not be an opaque, smooth surface of uniform finish, color, a toilets, as specified herein, and as required for a complete and equipment, and supplies required to install all items of the owner. y p appearance, r` proper installation acceptable. and coverage. Cloudiness, spotting, holidays, lops brush marks, SURFACE PROTECTION SYSTEMS SECTION 10265 supplied furnishings as indicated in the drawings and specified runs, sags, ropiness, or other surface imperfections will not be herein. 1.3 DELIVERY: acceptable. 1 .2 COORDINATION: 0...____.__, !<. Transparent (Clear) finishes: Use multiple coats to produce PART 1 - GENERAL: A. Coordinate accessory locations, installation, and sequencing 1.2 SECTION INCLUDES: A. Deliver materials to job site in original, new and unopened p duce with other work to avoid interference with and ensure a glass-smooth surface film of even luster Provide a finish free of proper A Quality Assurance: Comply with all standards in the related packages and containers bearing manufacturer's name and !abet lops, cloudiness, color irregularity, runs, brush marks, orange eel, 1.1 SECTION INCLUDES: installation, operation; adjustment, cleaning, and servicing of toilet o Store materials not in actual use in tightly covered containers. g p g sections. Use e only workmen who ore properly skilled, equipped, nail holes, or other surface imperfections. A. Perform surface preparation of substrate wall surfaces and accessory items and normally engaged in the type of work required, and are familiar Maintain containers used in storage of point in a clean condition, provide wall protection systems, where indicated on the drawings as with all requirements herein, and in the related sections. F free of foreign materials and residue. Keep storage area neat and 3.4 FIELD QUALITY CONTROL: specified herein and as needed for a complete and proper PART 2 - PRODUCTS: B Product Handling Accept delivery of all materials at the site orderly. Remove rags and water daily Take all precautions to A. The owner reserves the right to engage the services of an installation. Wall protection systems include: and store in o manner to prevent damage to parts and finishes. In ensure that workmen and work areas are adequately protected from independent testing laboratory to sample the paint materials being 1. Corner guards. 2.1 FASTENERS: the event of damage, make all replacements necessary to the 'l fire hazards and health hazards resulting from handling, mixing and used. Samples of material delivered to the project may be taken, 2. Rigid sheet wall covering panels. A. Screws, bolts, and other devices of some material as application of paints. identified, sealed, and certified in the presence of the contractor satisfaction of the architect and at no additional charge to the accessory unit, or of galvanized steel where concealed owner. The testing laboratory will perform appropriate tests as required by PART 2 - PRODUCTS 1.4 SITE CONDITIONS: the owner. If test results show material being used does not comply 2.1 SURFACE MOUNTED STAINLESS STEEL CORNER GUARDS PART 3 - EXECUTION:A. Apply points only when temperature of surfaces to be painted with specified requirements, the contractor may be directed to stop PART 2 - PRODUCTS: and surrounding air temperatures are within recommended range pointing, remove noncomplying paint, pay for testing, repaint A. Provide manufacturer's standard paper-covered No. 4 satin finish, 0.059-inch (16 gauge) minimum, AiSI Type 304 stainless 3 i INSTALLATION 2. 1 MATERIALS: """""""'] surfaces coated with rejected paint, and remove rejected paint from YP A. Install toilet accessory units according to manufacturers' permitted by the point manufacturer's printed instructions. Do not previously steel sheet corner guards, height as indicated, or minimum 4'-Q" '� 9 A. Furnishings: Furnishings to be provided by the owner for apply point when relative humidity exceeds 85 X or to damp or wet t painted surfaces if, upon repainting with specified paint, g g instruction, using fasteners appropriate to substrate as installation by the general contractor are as indicated on the the two coats are noncompatible. AFF. Provide 90-degree turn unless otherwise indicated and recommended b unit manufacturer. Install units plumb and level drawings, and include without limitation- menu boards, tables, surfaces. formed edges. Y p 3.5 CLEANING: firmly anchored in locations and at heights indicated. choirs, benches, countertops, booths, walls decorations, and all 1 Winq S;ze: 1 1/2 x t 1/2 inch 9 1 5 EXTRA MATERIALS A. During the progress of the work, remove from site discarded 2. Mounting Method- use non-water base clear silicone temp. B. Secure mirrors to walls in concealed, tamperproof manner other items shown. A. Upon completion of this section, deliver to the owner extra paint materials, rubbish, cans and rags at end of each work day. brace until silicone drys, with special hangers, toggle bolts, or screws. Set units plumb, B. Fasteners: Furnish all fasteners required for the secure stock equal to one (1) gallon of each color, type and sheen of paint Upon, completion of pointing work, clean window glass and other 3. Corner Radius: 1/8 inch. level, and square at locations indicated according to manufacturer's installation for materials of this section and in accordance with the used in the work Label each color accordingly. paint spattered surfaces Remove spattered point or otherwise instructions for type of substrate involved. drawings and any product literature furnished by the owner. damaged finish surfaces. Touchup and restore all damaged or 2.2 FRP PANELS: C. Install grub bars to withstand a downward load of at least 250 PART 2 - PRODUCTS: defaced pointed surfaces after completion of work of other trades. lb. Per ASTM F 446. PART 3 - EXECUTION 3.6 PROTECTION- A. 090" thick x 4' wide, "Marlite FRP", Almond, Class 111/C per 2.1 GENERAL: A Protect work of other trades, whether to be pointed or not, ASTM E084", or equal USDA accepted, semi-rigid fiberglass 3.2 ADJUSTING 3.1 INSTALLATION: A. Provide paint products equal to materials listed in the point against damage by painting. Correct damage by cleaning, repairing reinforced plastic paneling. Contact "Marlite" in Dover, Ohio at: A. Adjust toilet accessories for proper operation and verify that A. In general, install all ;t m in , ^ schedule included herein. Note that proprietary names used to or replacing and repainting as acceptable to owner Provide "wet 9 Items a workmanlike manner, using V , P P rY (216) 343-rang or (2olo 94or appr for loco! supplier(s). mechanisms function smoothly Replace damaged or defective care not to damage ports and/or finishes, and install in accordance 7 paint" signs to protect newt pointed finishes. Remove temporary B. Submit full ranger of colors far approval. items. with the drawings. Refer to Section #06100 for applicable Z designate materials are not intended to imply that products of Y P p ry named manufacturer are required to exclusion of equivalent protective wrappings provided by others for protection of their work standards governing the workmanship required for the work of this products of other manufacturers. after completion of painting operations At completion of 2 3 PANEL MOLDINGS. 3.3 CLEANING:construction activities of other trades, touch up and restore section.A. Provide one-piece matching trim and panel moldings at all A. Clean and polish all exposed surfaces strictly according to 2.2 MATERIALS: damaged or defaced pointed surfaces. joints between panels, and at top and bottom edges of panels, manufacturer's recommendations after removing temporary labels END A. Provide rimers and undercoat P y END OF SECTION 0900 P points reduced b the some B. Submit full rouge of colors for approval. and protective coatings. Q manufacturer as the finish coats. Use only thinners approved by r„ paint manufacturer, and use only with recommended limits. TOILET PARTITIONS SECTION 10150 2.4 FASTENERS END OF SECTION 10800 1 o U B. Match approved samples for color, texture, and coverage. A Provide aluminum, nonmagnetic stainless steel. or other Remove, refinish, or repaint work not in compliance with specified PART 1 GENERAL. noncorrosive metal screws, bolts, and other fasteners compatible KITCHEN EQUIPMENT SECTION 11230 requirements. with components hardware, anchors, and other items being Cn 1.1 SECTION INCLUDES: fastened. Use theft-proof fasteners where exposed to view. --- CZ) PART 3 - EXECUTION: A. Provide all labor, equipment, and materials necessary to Provide inserts and other anchorage devices for connecting PART 1 - GENERAL. U c components to concrete or masonry. Fabricate anchoringdevices a furnish and install all metal toilet partitions and urinal screens to be capable of withstanding imposed loads. Coordinate anchoring 1.1 SECTION INCLUDES: `-' 3.1 EXAMINATION. complete with fittings, hardware, and fasteners. 9 a- m A. Examine areas and conditions under which pointing work is devices with the. supporting structure. A. Provide all labor, materials, equipment, and supplies as 1.2 QUALITY ASSURANCE: rn to be applied and notify owner of conditions detrimental to proper A. Installer- All toilet partitions and urinal screens shall be required to complete all kitchen equipment work as indicated on the y and timely completion of the work. Starting of painting work will be 2.5 FABRICATION drawings V , CA r-� installed by skilled personnel completely familiar with the gs and specified herein. �, construed as acceptance of surfaces and conditions manufacturer's recommended methods of installation, and A Fabricate wall and door protection systems to comply with B. Furnish and install oil items as indicated on the Equipment v 3.2 PREPARATION requirements of this work, requirements indicated for design, dimensions, details, finish, and Schedule to be furnished and installed by the general contractor. A. Prepare surfaces and apply coatings in strict accordance member sizes, including wall thicknesses of the components. C. Install and make all required final utility connections to those B Codes Installation shall be ir. strict accordance with all r q ` I with the coating manufacturer's recommendations. Preassemble components in the shop to the greatest extent items indicated on the Equipment Schedule. pertinent requirements e ANSI and/or Mass. Architectural Access possible to minimize field assembly Disassemble only as �� Q. Clean surfaces of dirt, rust, scale, grease, moisture, or other Code, and .ADA (latest edition) and/or local requirements for the � [DATE RAWN tin __ conditions otherwise detrimental to formation of a durable paint film. necessary for shipping and handling. Fabricate components with 1.2 QUALITY ASSURANCE C physically handicapped tight seams and joints with exposed edges rolled. A. Use only workmen who are PPR._- Perform preparation and cleaning procedures ;n accordance with 1.3 SUBMITTALS: y properly skilled, equipped, and -� �� B. Provide surfaces free of evidence of wrinkling, chipping, normally engaged in the type of work required, and are familiar with _ ___`_ G paint manufacturer's printed instructions for each particular A. Prior to fabrication, submit complete shop drawings showing uneven coloration, dents, and other imperfections Fabricate o substrate condition P all requirements herein, and in the related sections.layout, method of construction, hardware, and method of members and fittings to produce flush, smooth and rigid hairline __^'(. Remove hardware, accessories, plates, lighting fixtures, and -- installation. Submit manufacturer's standard palette of finishes and joints. 1.3 SUBMITTALS: SCALE_ N.T_.S.__ i sirn;lor items in place and not to be finish-painted, or provide n surface-applied protection prior to surface preparation and pointingcolors for the architect's selections. C. Provide wall brackets, flanges, miscellaneous fittings, and A. Submit complete shop drawings for afl tabricated items _ _ ___ anchors for interconnection of members to other construction, intended to be drawings showing all dimensions, sections, fastening CAD FILE operations. Remove, if necessary, for complete painting of items Provide inserts and other anchorage devices for connecting 9 details, material gouges, finishes, and similar features of the H:\PAPAGINO\HYANNIS an adjacent surfaces. Following completion of __r_ _-___ _________.__. Cn J 9 p painting of each components to concrete or masonry Fabricate anchoring devices fabrication or component being furnished. Identify all cc space or area, re-Install removed items. p g y parts in the JOB NO. 98066 rn g to be capable of withstanding imposed loads Coordinate anchoring some manner as identified ;n the Equipment Schedule. D. Clean wood surfaces of dirt, oil, and other foreign , substances with scrapers, mineral spirits, and sandpaper, as devices with the supporting structure. _ �__.____..________ ___ SHEET required Sand surfaces exposed to view smooth and dust off. 1.4 PRODUCT HANDLING: _ Scrape and clean small, dry, seasoned knots and apply a thin coot A. Deliver all materials to the site and store ;n a manner to of white shellac or other recommended knot sealer before prevent damage furnished and to parts and finishes. ;n the event of o damage, make all replacements necessary, to the satisfaction of the u� application of primer. After priming, fill holes and imperfections in ry' finish surfaces with putty or plastic wood filler. Sand smooth when architect and at no extra cost to the owner ) N �_M dried. is section3 Ur)a Q, ra �s :if rN( 7REVlS,,N, DATE EB- -- coo 01 x ,= & Sb _ J �a(7C1 H H H H H " 1 J iO2 J j � •/ A^1 EB-2 a —LP-- t H H3 Ir 3t; 3b J L .. F-B -2 i A A. LP-5 A A LP-2 06 06 O- 06 3b 3b 3b G C � 0 N _ _.._ --+- _.__� - - - __ EB- 1 2 02 ` + c N EB-2 E 5a F-- J _ - _. i ;`n r: _ 2 62 N. F E t E E E -- . 7 �HOOD � 9 9 0 9 9 A AO A I A 6 6 6 06 0 w of�rgSS LIGHTING PROVIDED BY LP-4 A 4 A04, A 4. � PE tt MARCR. COOLER MANUFACTURER SEE DWG. E-2 FOR r LP-6 A� EL N Ak , ELECTRICAL CONNECTION, H A A A sr! o� A0j SSiONAI ENG q A® 4 _.. 4 4 _. A0 A A0 AQ — LP1 LP--7 E ! # r LP10 —1 1 J C EMERGENCY -------- m 1 C-- -�I �4t4 O41 V4 �.04 C C �'- WP PATTERY UNIT _ # L 1_ 2 2 J EB-2 1 EB—' T T .. w 2 2 �S NAGE R EMERGENCY ---- - - w J - t _ - ._.. t - _ - i.. wi .. i.i.. M_'- _�.: Sf 1 Gr1 � E i - t _ + BATTERY UNIT /� � 1 "EB_1 " J �1 E-v- EB-2 t. A t J ♦ A A # i A WP Z CV E;B-1 T-E J I LP- 1 G r"; 6 LP-8 ! � �6 0 � Z t I �( Z - E E p4 04 �'"; 04 04 EB—1 < LP- t• _. _ j.� C i Q ~cy- 3- 1 1 G -+ l 02 FLOOR PLAN LIGHTING SCALE: 1/4'-1'-a LIGHTING FIXTURE SCHEDULE r— I MANUFACTURER & LAMPS YPE DESCRIPTION CATALOG NUMBER NUMBER TYPE VOLTS REMARK: A DEEP CONE RECESSED CV8-1JUN032E-2388 1 E�23DT 120 B NOT USED y C STANDARD DOME ABOLffE 1 CF32DT 120 PROVIDE TYPE SJO BLACK CORD GREEN GLOSS RLM STAND DOME G-15 GREEN GLOSS E/835 LIGHTOLIER ' STEP CYLANDER TRACK D TRACK LTG. 9630 BK HEAD ! SW PAR30 120 UGHTOLIE_R 9108BK t Cr) �MELALUX E 1X4 WRAP AROUND W232A120V 2 FOT8 120 Z w 1 . ALL EXIT LIGHTING FIXTURES SHALL BE ON CONSTANT CIRCUIT --- 4'-0" FLUORESCENT FURNISHED BY AWNING SUP., FL55 FROM PANEL "LP" CIRCUIT #7. HO VAPORITE INSTALLED BY E.C. 1 HO 120 2. ALL LIGHTING BRANCH CIRCUITS SHALL RUN THRU PANEL "LP" AND n _ CONTACTOR/RELAY PANEL WITH REMOTE SWITCH. LP 1 - 3. ALL WIRING, CONDUIT BOXES TERMINATIONS TO ALL FLOURESCENT 2#12, 1/2"C Fl NOT USED FIXTURES IN AWNINGS SHALL BE WEATHERPROOF. TYPICAL FOR ALL ---� _ LIGHTING CIRCUITS ASTRONOMIC TIMESWITCH, COLUMBIA (SEE NOTE #2) TORK #720OZ, SET TO TURN ON 2X4 FLOURESCENT TROFFER J243322GFSA12EB812D 3 F032/735 120 AT 5:00 AM AND OFF AT 1:00 AM ON A 24 HRS/DAY LOCK ON DECORATIVE GOOSE ABOUTE CIRCUIT L NECK LIGHTS HMDM 400-615 1 7`-'.W 120 WITH WM3-6N24-3-SP GOOSENECK BRACKET �� olo CONTACTOR ! 1 — N OP.gwN smm CABINET - --+- EMERGENCY HEAD (2) PRESCOLITE 8W HAL 4PPR. #ELHD-H1208 2 EXT-P5SB 1120 R DA'E 10-09-1998 I I WP PRESCOLITE 8W HAL SCALE „ I I EMERGENCY BATT 1 12Q i 4 - 1,_Q 7 i 1 LIGHTS --7 HEAD WEATHERPROOF #EWP-1212 EXT-P5SB L--------J ;AD FILE TYPICAL H:\PAPAGINO 98194 EXIT LIGHTING JUNO t ARROWS AS INDICATED W EMERGENCY BATT EXG-51 LED 120 'OB NO. / ON PLANS 98066 1 NAGE AND EXTERIOR LIGHT CONTROLDIAGRAM EMEtGENCY BATTERY PRESG01_ITE L:l�(�ING CONTR SHEETEB1 illg EB2 #ET12 KmEngineering Resources, I pc. �- I'LL•(508) 2,30-0260 Shovel Shop Square FAX: (508)230-0265 28 Main Street, Bldg 3A B>r R7207#A0L.C(7R1 'No- Easton, MA 023Y Ci Ri '.tON5 DATL HOOD ANSUL SYSTEM CONTROL EF PANEL (VERIFY EXACT LOCATION 2 EF 510 WITH MECHANICAL DRAWING) 402 CONNECTION 118 FOR HOOD- 4 / /PP1-36 + #� CONTROLLED BY LIGHT SWITCH J 2 : hi- GFI KP1 KP2 ♦ 1 �' PP2 73 PP2-2 IC: 109 SEE NOTE #4� , PP2--37GAS FIRED HOT 118 - 120 PPPP2-9_______- WATER HEATER PP1-35 402 - ui N MDP 7 PP2-17 r----r- -- - -s CS F CONNECTION FQR—� 147 I o I co I i MUA --�PP2-1 + WATER HEATER PP 1-33 a a a a ---4#6,1#10G, 1"C j ja 137 -� ,e� CONTROLS 114 PP2-4 a rl PP1-20 PP1-39 116 403 PP1 -30 Ia I Imo. 12 ---_ .` I ° 125 P13 P1 -32 ttL_y�-,a. PP1 -14 _� a a 'LP _ ft60�_66TT— ppPP2_25 -J TO LIGHTING- CONNECTION 117 I 102 IG CP PP1 -37 . FOR HOOD �� WVP I t�PI-28 � 48' 'MDP PP2-35 J , I J J PC CAE3INET 404 GFi i. I AC ------1- __- — F F -- PP2-34 J I I --- _..._....�....� 3 IG ,\ ' '=`�� TO DOOR HEATER PP2-31 J `__{-- ! I ' �\--PP1 -18 _ ,� ---1- -PP2-29 405 FREEZER COOLER PP2_33 J _ ___ _. -__ _r 515� T EVAPORATOR EVAPORATOR � PP1-25 ABOVE PP2-13 SD 121 EF 1 CONNECTION FOR r .0� 0 3 /3 OVEN CONTROLS 110 r N r) rn r r � 0, 0) J FREEZER CONDENSER--- I r T �►►'�' ON ROOF { { 102B { i { I 1 i i PP 1-32 ✓�R4�H Of I!, v 30/30/3 -�-----M- 30/30/3 0- 119 Q a 112 a a a ci ci a s rL a a. cl_ a a. a. a a 402 � �� MARC R. p E ELAN AL y LL 3#10,#10G, 3/4"G --- �3 403, 136 L c PP2-1 1 J Nq\t9 ` 3#10,#10G, 3/4"C �---�PP1 -34 j7 �403 / GF! = / r 104 fG"' G. tG' 1 wr MDP-1 _____ r 118 PP 1 7�---- {�4 r __— _ _ _ 1__ ��c PP2-10 / PP2-16 a _ I 1 4 6.1 10G 1 r,. SS/ONAL�N 1 - COOLER CONDENSER --I -----►-PP2-2 ° _ ,+ - _._. , - I I # # r ON ROOF t a CS 402 (403 403 ,{T\_ - -- REFER TO NOTE #7 (TYPICAL) I �AC I I 3 - Ii _ I -rx - r+r i j; 402 P.O.S. l 1 1 1 GFI + , rlT +'� P.O.S. P.O.S. I I 6 6 /3 J PP1-22 GFI J. I C Y4 I -._--- -__.___ j 502 °° -- � I J D PP1 a [F] — --�.-PP2-3 F V w PP1-26 PP2-36 (� HD ' I ' rr ca fl N Z N N M I I , { rQ Z N.- N N N W U,.I1 Q J a a a a a a a a. a a OL~ 0! _ EF 11/4 1 1 CS 503 L23�5 525 �525 525 v FLOOR PLAN - POWER + SIGNAL w O �QTU. 1 . REFER TO EQUIPMENT CONNECTION SCHEDULE DRAWING E-3 FOR EQUIPMENT DESCRIPTION, ELECTRICAL CHARACTERISTICS AND INFORMATION WIRE & CONDUIT BRANCH CIRCUIT SIZING. 2. REFER TO DRAWING E4 FOR PANELBCARD SCHEDULES, RISER DIAGRAMS ETC. 3. ALL ELECTRICAL EQUIPMENT BOXES, CONDUIT, WIRING DEVICES ETC. WITHIN WALK IN BOXES SHALL BE: WEATHERPROOF. ALL CONDUITS ENTERING BOXES SHALL HAVE SILICONE FITTINGS AND SEALS. 4. CONNECT TO ELECTRONIC GAS VALVE AND INTERCONNECT WITH ANSUL SYSTEM CONTROL VALVE SO THAT THE COOKING LINE WILL SHUT DOWN ON .ACTIVATION OF ANSUL SYSTEM. 5. ALL RECEPTACLES WITHIN KITCHEN AREAS LOCATED WITHIN FIVE FEET OF OPEN WATER SHAD. BE GROUND FAULT INTERRUPTER TYPE. ,_....1 ,a..,.j 6. ELECTRICAL CONTACTOR SHALL COORDINATE ALL ROUGH--IN DIMENSIONS AND MOUNTING HEIGHTS WITH EQUIPMENT CUTS. a- HEIGHTS FURNISH AND ;NSTALL AT EACH "POS" STATION OUTLE1 BOX AND 3/4" CONDUIT BACK TO PC CABINET. PROVIDE PULL LINES AND LABEL EACH END. ALL "POS" CABLING By PAPA GINO'S 8. EXACT LOCATION OF ALL "POS" RECEPTACLES ETC. SHALL BE COORDINATED WITH PAPA GINO'S 9. ALL DUPLEX RECEPTACLES INDICATED BY "CS" SHALL BE "CHILD SAFE" DEVICES AND DEVICE PLATES. 10 RUN ALL CONDUITS FOR CENTER CABINET UNDER GROUND WITH SEPERATE CHASE FOR DATA LINE. t 0 �..� 86 eo C)R A WN APP° RF DA11 10-09-1998 SCALE 4" ( AD rill H: PAPAGINQ 98199 t Jcq NO. 98066 SHEET Building LngineF: ring Ke'sou rces, 1 Tic. TEL:(508) 23"260 Shove! Shop Square F'A\- (508) 230-0265 28 Main Street, Bldgg. 3A BER72071" OL.COM No. Easton, MA 02' Imo. REVISIONS GATE EVW LECTRICAL SPECIFICATION'S: 1 . 'LrIF WORK COVERED BY TH15 CONTRACT 'HALL. INCLUDE UNLESS -------- SYMBOL LIST SPECIFIED OTHERWISE, THE FURNISHING OF ALL LABOR, EQUIPMENT, TOOLS i - KITCHEN EQUIUPMENT SCHEDULE: AND MATERIALS, AND THE PERFORMANCE OF AL.L. OPERATIONS NECESSARY' FOR - �--- _ PROPER AND COMPLETE EXECUTION 'OF THE WORK IN ACCORDANCE WITH THESE ITEM QT". DESCRIPTION rVOL+PH AMPS HP w BREAKER CON. MTG. HEIGHT M E & CONDUIT FLUORESCENT LIGHT FIXTURE - REFER TO FIXTURE SCHEDULE NON-FUSED DISCONNECT SWITCH - RATINGS AS INDICATED SPECIFICATIONS AND THE:. DRAWINGS SUBJECT TO THE TERMS ANC) CONDITIONS ON PLAN OF THIS CONTRACT_ ELECTRICAL WORK SHALL INCLUDE BUT NOT LIMITED TO DEMOLITION, TEMPORARY LIGHT AND POWER, EMERGENCY LIGHTING, FIRE 102 1 REFRIG. WORKTABLE 120 1 78 1 4 936 20A-1 P 18" AFF 3 12,3/4"C ALARM SYSTEM, DISTRIBUTION EQUIPMENT, LIGHT FIXTURES, DEVICES, }/ # RECESSED OOWNUGHT FIXTURE - REFER TO FIXTURE SCHEDULE SAFETY SWITCHES, CONTROL WIRING, BRANCH CIRCUIT WIRING, AND 102A 2 REF. SANDWICH UNIT 120 1 8.7 1/4 1044 20A-1 P 18" AFF 3#12.3/4"C Z-I FUSED DISCONNECT SWITCH - RATINGS AS INDICATED CONNECTIONS NECESSARY TO OPERATE MOTORS AND OTHER EQUIPMEN I ZA TRACK `LIGHTING FIXTURE -- REFER TO FIXTURE SCHEDULE ON PLAN 2. ALL WORK SHALL BE INSTALLED, BY LICENSED ELECTRICIANS IN A FIRST CLASS MANNER CONSISTENT WITH THE BEST CURRENT PRACTICES, ITEMS NOI 1028 1 U.C. REFRIGERATOR 120 1 6.1 1/4 732 20A-1 P 18" AFF 3#12,3/4"C SHOWN ON THESE DRAWINGS, BUT WHICH ARE NECESSARY TO MAKE A COMPLETE 103 2 SOUP WARMER 208 1 3.0 - 620 20A-2P Q ? # / " ( EXIT SIGN F MANUAL FIRE ALARM PULL STATION OF THE ELECTRICAL INSTALLATION, SHALL BE FURNISHED AND INSTALLED AS PART 8" AFF 3 12,3 4 C 3. A O ALL WORKSHA I CONTRACT.BE INSTALLED IN CONFORMANCE TO THE 1996 MASSCHUSETTS 104 1 PIZZA PREP REFRIG. 120 1 8.8 1 /3 1056 20A-1 P 18" AFF 3#12,3/4"C STATE_ BUILDING CODE AND THE MASSACHUSE'T T S ELECTRIC CODE AND ALL OTHER �' z c FIRE ALARM AUDIO/VISUAL UNIT GOVERNING CODES, REGULATIONS AND ORDINANCES, THESE REQUIREMENTS ARE A 107 1 FRUITOPIA DISPLAY 120 1 1 -- 200 20A-1 P 48" AFF 3#1 2,3 4"C F MINIMUM CRITERIA AND NO REDUCTIONS IN STANDARDS CALLED FOR ON THE / ZZ EMERGENCY BATTERY UNIT DRAWINGS PERMITTED BY CODE, WILL BE ALLOWED. 4 OBTAIN AND PAY FOR ALL INSPECTIONS, LICENCES, PERMITS AND ak+' 109 1 FREEZER (UPRIGHT) 120 1 7.6 1/3 912 20A-1 P 18" AFF 3#12,3/4"C 17 FIRE ALARM VISUAL_ UNIT APPROVALS REQUIRED BY GOVERNING AUTHORITIES AND INSTALL ALL WORK IN S SINGLE POLE TOGGLE SWITCH COMPLIANCE: THEREOF. CARRY PERSONAL AND LIABILITY INSURANCE WITHIN 110 1 SODA MACHINE 120 1 - 750 20A-1 P 18" AFF 3#12,3/4"C THE LIMITS PRESCRIBED BY THE OWNER. o PHOTOELECTRIC SMOKE DETECTOR 5 ALL MATERIAL_LS AND WORKMANSHIP SHALL CARRY THE STANDARD WARRANTY SD 112 1 COFFEE AGAINST ALL. DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE BREWER 20$ 1 26 - 6250 40A-?_P (a► 48" AFF 4#8,3/4"C S3 3-WAY TOGGLE SWITCH DATE OF ACCEPTANCE: OF THE WORK. ANY FAULT DUE TO DEFECTIVE � MATERIALS, EQUIPMENT, OR WORKMANSHIP WHICH MAY DEVELOP WITHIN THAT 1 14 1 ICE MACHINE 120 1 12,9 - 1548 20A-1 P Q 48" AFF 3#12,3/4"C ND 1357 FIXED TEMPERATURE THERMAL HEAT DETECTOR PERIOD SHALL. BE MADE GOOD, FORTHWITH, BY AND AT THE EXPENSE OF THE " -- ELECTRICAL CONTRACTOR, INCLUDING ANY DAMAGE DONE TO AREAS, ■ � 115 1 MENU BOARD 120 1 - - 200 20A--1 P J VERIFY 3 12,3 4"C MATERIALS, AND OTHER SYSTEMS RESULTING FROM THIS FAILURE. ALL # / ® RECEPTACLE EQUIPMENT SHALL FEE NEW, SPECIFICATION GRADE AND LISTED BY U.L. 116 1 MICROWAVE 120 1 20 - 2000 20A-1 P 48" AFF 3 12,3 4"C' 111 TELEPHONE OUTLET 6. DURING THE PROGRESS T OF WORK MARKUP .A SET OF CONSTRUCTION # / IG DOCUMENTS TO REFLECT THE WORK AS IT IS ACTUALLY INSTALLED. ASBUILT 1p ISOLATED GROUND RECEPTACLE RECORD DRAWINGS SHALL BE PROVIDED AND TURNED OVER TO THE OWN!~9 UPON 117 1 PIZZA OVEN CONTROL 120 1 7 840 20A-1 P 18" AFF 3#12,3/4"C COMPLETION PRIOR TO FINAL PAYMENT. MOTOR 7, REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION OF 118 3 PHONE SYSTEM 120 1 - - 20A-1 P 18" AFFF3# 2,3/4"C GFI EQUIPMENT AND CEILING LIGHT FIXTURES. 8. ALL LAYOUTS ARE DIAGRAMMATIC AND FINAL ARRANGEMENT SHALL SUIT Ah RECEPTACLE MOUNTED ABOVE: COUNTER FIELD CONDITIONS. PROVIDE A COMPLETE BRANCH WIRING SYSTEM TO ALL 1 19 1 SLICE WARMER 120 1 14 - 1680 20A-1 P 48" AFF2,3/4"C DOORBELL LIGHT FIXTURES, SWITCHES, RECEPTACLES, ETC. FOR A COMPLETE GFI DENOTES GROUND FAULT INTERRUPTION ❑ OPERATING SYSTEM. ►►_" 120 1 PASTA COOKER 120 1 3 - 360 20A-lP 18" AFF 3#12,3/4"C C4 RECEPTACLE WITH WIRE LEADS 9. THIS CONTRACTOR SHALL CONFER WCTH ALL OTHER CONTRACTORS AS TO ��NOFM THE LOCATION OF THEIR WORK BEFORE BEGINNING THE ELECTRICAL WORK. HE s��4 Rss TAMPER RESISTANT �o SHALL INSTALL THE ELECTRICAL WORK IN SUCH A MANNER AS TO AVOID moo`' yc�, » El FOR DOORBELL MA . 121 1 WALK-IN COOLER/FRZ 208 3 50 3 3000 30A-3P VERIFY 3#10,3/4 C HUBBELL #FiBLSG63H (CHILD SAFETY) INTERFERENCE WITH ALL OTHER TRADES RL R Q PC I 10. PlIS CONTRACTOR SHALL VISIT THE: SITE AND VERIFY THAT THE 0 ELECTRI L 125 1 SODA SYSTEM 120 1 - 113 - 20A-1 P 0 VERIFY 3#12,3/4"C EXISTING CONDITIONS ARE AS DESCRIBED ON THE DRAWINGS AND THAT NEW No. 9 - - SPECIAL PURPOSE RECEPTACLE - REFER TO EQUIPMENT 0 TRANSFORMER WORK IS COMPATIBLE WITH EXISTING CONDITIONS, ANY CONFLICTS BETWEEN C � 130 2 BEVERAGE MERCH. 120 1 1 - 200 20A-1P Q 3#12,3/4"C ® SCHEDULE FOR RATINGS. DRAWINGS AND FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF" �/ O� 1 Te THE ARCHITECT IN WRITING BEFORE THIS CONTRACTOR SUBMITS HIS PRICE S�ONAL'rN 136 1 EXH. HOOD PIZZA 120 1 7 - 840 20A-lP 3#12,3/4"C 1 FOR THE WORK. NO EXTRA COMPENSATION WILL BE PROVIDED IF THIS CALL FOR AID PUL.LSTRING CONTRACTOR FAILS TO COMPLY WITH THESE. REQUIREMENTS. __♦.. HOMERUN TO PANEL 11. CUTTING, PATCHING AND CORE DRILLING SHALL BE PROVIDED FOR THE 137 1 EXH. HOOD GRILL 208 3 5 - 600 20A-3P Q :3#12,3/4"C INSTALLATION OF ELECTRICAL WORK.SLEEVES SHALL BE PROVIDED FOR FRCP CONDUIT THAT PASSES THRU FLOORS, FIRE RATED WALLS, ETC. FIRE 139 1 WATER FILTER SYSTEM 120 1 - - - 20A-1 P Q 60" AFF 3#12,3/4"C O JUNCTION BOX FIRE ALARM CONTROL PANEL BARRIER SEALING SYSTEM SHALL BE FURNISHED AND INSTALLED TO MAINTAIN 0 THE INTEGRITY OF RRF RATED CONSTRUCTION. 12. SUBMIT SHOP DRAWINGS OF .ALL EQUIPMENT AND MATERIALS TO BE 141 2 FRYER 120 1 8.4 113 1008 20A-1 P 18" AFF 3#12,3/4"G RAf REMOTE ALARM INDICATOR INCORPORATED IN THE WORK.. THIS CONTRACTOR SHALL ASSUME ALL COST FOR ANY ADDITIONAL CORRECTIONS, SUPPORTS, OR CONSTRUCTION REQUIRED FOR 147 1 SLICER 120 1 - 500 20A-1 P 48" AFF 3#12,3/4"C MATERIALS WHICH ARE SLIBST!TUTED FOR THOSE SPECIFIED. f ,� 13. GROUNDING METHODS SHALL. BE IN ACCORDANCE WITH ARTICLE 250 OF THE 2 401 1 CASH ADVANCE 120 1 NATIONAL ELECTRIC CODE. PROVIDE A SEPERATE: GREEN GROUNDING CONDUCTOR FOR ALL. BRANCH CIRCUITS. Z 14. SERVICE PANELBOARDS ARE: NEW THIS CONTRACTOR IS RESPONSIBLE a 402 5 TERMINAL 120 1 1 - 200 20A- 1 P - - FOR ALL. BRANCH CIRCUIT BREAKERS AS SHOWN ON PANEL SCHEDULE. 403 6 PRINTER 120 1 1 - 200 20A-1 P VG - - 15. ELECTRIC METALLIC TUB!NG(EMT) MAY BE USED WHERE RUN IN CEILING ' Z SPACES, FURRED WALL SPACES AND EXPOSED. STEEL SETSCREW FITTINGS < Z 404 1 PROCESSOR 120 1 1 - 200 20A-1 P -. -- WITH INSULATED THROATS FOR EMT SHALL. BE USED. NO MORE THAN 3 PHASES ry AND 1 NEUTRAL IN ANY SINGLE CONDUIT, MINIMUM 1/2" CONDUIT. LIQUID-- ,Q 7Q,,, TITS FLEXIBLE CONDUIT SHALL BE USED FOR FINAL_ CONNECTIONS TO 405 1 STAND-BY POWER 120 1 l - 200 20A.-lP � - -- TO&&LE 50NITGH YOUTH ONE- EQUIPMENT SUBJECT TO VIBRATIONS. SUPPORT CONDUIT AT INTERVALS AT NO d- w _ 0) NYLON PULL CORD --- TO R.ESPEC,.rI,,/E -TOILET ROOM MORE THAN SIX FEET, AND 12 INCHES FROM ANY BOXES, ELBOWS, OR RECEPT CIRCUIT 5M FLOOR PLAN. FITTINGS. RACEWAYS SHALL BE CONCEALED IN FINISHED AREAS, EXPOSED IN EN&502 2 HAND DRYER 120 1 - - 1200 20A-1P Q VERIFY 3#12,3/4"C WITH S.S. C.OEME PLATE UNFINISHED AREAS SUCH AS ELECTRICAL ROOMS. FEEDERS SHALL. BE ROUTED AUTRAYED "EMER6EDEL HIGH AS POSSIBLE, PARALLEL. AND PERPENDICULAR TO THE BUILDING AUTI�,iF"LG�tJRENGE MODEL STRUCTURAL SUPPORT SYSTEM. 503 1 JUKE BOX 120 1 1 -- 500 20A-1 P � 18" AFF 3#12,3/4"C 16, CONDUCTORS SMALL BE COPPER, SOFT DRAWN AND ANNEALED OF 98°! p CONDUCTIVITY. ALL CONDUCTORS #10 AND LARGER SHALL BE STRANDED A Sfl5 1 TV/VCR 120 1 500 20A-1 P VERIFY 3#12,3/4"C CONDUCTORS SHALL BE INSULATEi� ALL FOR 600 JOLTS, AND SHALL BE INSTALLED � IN CONDUIT CONCEALED IN THE NEW CONSTRUCTION.MINIMUM WIRE SIZE IS i Q VERIFY 3#12 3/4"G -`_— --_---- T- ( AuTi-VV1'LORENGE T!OF #12 AWG. THE USE. OF METAL.-CLAD MC.) CABLE WITH FULL SIZE GROUND 512 1 MICROPHONE 120 1 ��OA-1 P T'RAN5Fc7RMCR WILL BE PERMITTED FOR WIRING OUTLETC WHERE CONCEALED ABOVE CEILINGS 525 4 VIDEO GAMES 120 1 - - 500 20A-1 P 18" AFF 3#12,3/4"C I OR IN FURRED WALL SPACES IF ACCEPTABLE TO THE AUTHORITY HAVING t. JURISDICTION. ONLY STEEL GROUNDING TYPE: CONNECTORS WITH NYLON a. T INSULATION WILL BE ACCEPTABLE. NO EXPOSED "MC" CABLE WILL BE I ALLOWED THE USE OF "MC--LITE" CABLING IS NOT ALLOWED. I 17. ALL OUTLET BOXES SHALL BE GALVANIZED CADMIUM-PLATED OR ZINC- I COATED SHEET METAL TYPE 1 18. FURNISH LIGHTING FIXTURES COMPLETE WITH STANDARD OR SPECIAL I MOUNTING FRAMES,LAMPS, BALLASTS, AND OTHER DEVICES OR ACCESSORIES, I COR :0OR D-O"E 5TATION AS REQUIRED FOR A. FIRST CLASS INSTALLATION. FLUORESCENT FIXTURES 1 Y*41TE WITS+ ONE RED LAMP SHALL BE FURNISHED WITH ETL/CBM CERTIFIED ENERGY SAVING BALLAST AND ONE CLEAR LAMP EQUAL TO G.E. MAXI-MISER 11 BALt.A.ST TO BE CLASS P FOR OPERATION 1 AND E ZZER CV*' OAF 5YNITGH AT 120V, HAVING A SOUND RATING "A". FLUORESCENT LAMPS SHALL BE �}-�_------, OV`1rLr?RE'NGE ELEGTR01vIG5 ENERGY-SAVER TYPE EQUAL TO G.E. WATT-MISER It. ALL FIXTURES SHALL_ L==� MOVEL.. 0308E WITH E0.2 5ERIE5 BEAR A U.L LABEL. FIXTURE. TYPES TO BE AS INDICATED ON DRAWING PULL " BAGKt30x SCHEDULES. LIGHTING FIXTURES SHALL BE INDEPENDANTLY SUPPORTED FROM ., O� f-C� `� ---------T01FT ROOM A STRUCTURAL BUILDING MEMBER. ROOF DECK AND SUSPENDED CEILING EXT"MiOR y�+,L,;,� SYSTEM SHALL NOT BE USED AS A SUPPORT FOR LIGHT FIXTURES. I 48" 19. LOCAL WALL SWITCHES SHALL BE RATED 20 AMPS, HUBBELL #1201, Z 1 SINGLE POLE. POWER RECEPTACLE FOR MOUNTING IN INDIVIDUAL WALL BOXES W SHALL BE RATED 20 AMPS, HUBBELL #5352, DUPLEX.WALL DEVICE PLATES FINI5HM FLOOR SHALL BE EQUAL TO HUBBELL BRUSHED STAINLESS STEEL. COLOR OF ALL 12 EXPOSED PARTS SHALL BE AS SELECTED BY THE ARCHITECT, 20. DISCONNECT SWITCHES SHALL_ BE NEMA HEAVY DUTY TYPE HD" AND U.L. LISTED. SWITCHBLADES SHALL BE FULLY VISIBLE IN THE OPEN POSITION Uj .1. - PADLOCKING PROVISIONS REQUIRED FOR BOTH THE "ON" AND "OFF" POSITION. SWITCHES INSTALLED EXTERIOR TO THE BUILDING SHALL BE a PROVIDED WITH A NEMA. 3R ENCLOSURE WHEN INDICATED FUSES SHALL BE (D DUAL ELEMENT, TIME DELAY TYPE -»- IF HANDICAPPED TOILET REQUIRED FURNISH AND INSTALL GALL FOR 21, THIS CONTRACTOR SHALL INSTALL. AND MAKE FINAL CONNECTIONS TO All ° EQUIPMENT PROVIDED BY THE OWNER WHERE INDICATED ON THE PLANS. < AID 5!6NALIN& DEVIGE5 A5 SPECIFIED, ALL EQUIPMENT D15TIBUTED 22. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM IMPROPER BY MAMMOTH FIRE ALARM, LOMEL, MA GROUNDS AND SHORT CIRCUITS. ANY DEFECTIVE ITEM IN THE WORK MADE_ _-5 EVIDENT BY TEST SHALL_ BE CORRECTED BY THIS CONTRACTOR TO THE - SATICOSSFACTION OF THE ARCHITECT AND THE ENGINEER AT NO ADDITIONAL_ � �g 23. MARK ALL EQUIPMENT FOR EASE OF IDENTIFICATION. PROVIDE BLACK EN ANDr�PANE BOARDS.TES COVERPLATESWITHEFORGJRUNCTIONOBOXXES SHALLTBEWITCHES IDENTIFIED AS TO SYSTEM AND FUNCTION BY MEANS OF FIBRE PEN PROVIDE A LAJ .3..I TYPEWRITTEN DIRECTORY CARD FOR THE PANELBOARD. 24. THE BUILDING WILL BE OCCUPIED DURING THE PERIOD OF - --- CONSTRUCTION. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK f'. 9 WITH THE OWNER, GENERAL CONTRACTOR AND ARCHITECT. WORK WILL BE Li PO CALL FOR AID AL ARt� SCHEDULEDTO CAUSE THE LEAST INCONVENIENCE TO THE OPERATION OF THE ILW ,". -- --— FACILITY. NO SCALE 25, PANFBOARDS SHALL BE AS SCHEDULED ON THE CONTRACT DRAWINGS. PANELBOARDS SHALL. BE SURFACE OR FLUSH MOUNT TYPE AS INDICATED AND DRAWN INSTALLED SO THAT THE TOP CIRCUIT BREAKER IS NO MORE THAN 6'-6" ABOVE SMM THE FINISH FLOOR IT SHALL BEAR THE UL LABEL. ALL BUSES SHALL BE 98% [APPR CONDUCTIVITY COPPER. A TYPEWRITTEN CIRCUIT DIRECTORY CARD SHALL BE RIF MOUNTED IN A FRAME INSTALLED ON THE INSIDE OF THE DOOR, ALL CIRCUIT BREAKERS SHALL. HAVE BOLT-ON BUS CONNECTIONS. MULTIPOLE BREAKERS SHALL DATE 10-09-1998 BE COMMON--TRIP TYPE. CIRCUIT BREAKERS SHALL BE TYPE QOBVH. PANELBOARD SHALL BE EQUIPPED WITH A NEUTRAL BAR AND GROUND BAR HAVING ONE SCALE t 4" = 1'-0" SOLDERLESS CONNECTION FOR EACH CIRCUIT, AS INDICATED. PANELBOARD CAD FILE AND CIRCUIT BREAKER RATINGS SHALL. BE AS SPECIFIED ON THE DRAWINGS, H: PAPAGINO 9$t 951 SHORT CIRCUIT WITHSTAND RATING SHALL BE AS INDICATED ON THE SCHEDULES. PANELBOARD SHALL_ BE SQUARE D, TYPE NQOD )Of 140, 98066 Building `3HLtT Engineering Resources, I ric. E - 3 "I EL:(508) 2.30-0260 Shovel Shop Square FAX: (508) 230-0265 28 Main Street, Byt. :3A BER72070AOL.C'OM No. Easton, MA 02.1, ,.:.. a :. tiC9i- �rYsl' -00 n.rc g rc A low NO. REVISIONS DATE VOLTS 120 208 MAINS 100 MLO VOLTS 120 MAINS 20UA MLO VOLTS _2 2�8 MAINS 200A, MLO PHASE 3 PANEL SCHEDULE BUSSING 1 DOA _ PHASE 3 PANEL S C i I E D U L E BUSSING 200A ' PHASE _ 3 PANEL SCHEDULE BUSSING,; .200A WIRE 4 FEED 4 - WIRE a i FEED 4 3 0 i WIRE _ 4 FEEDz A.I.C. 1 ,000 PANE pl P" MOUNTING SURFACE A.I.C. _ 10,000 PANEL_. "PP1" MOUNTING SURFACE � A.I.C. � ?Q,c�u� 1� A N E I.__ 'PP2" MOUNTING S�!RFAc,E SERVICE WATTAGE WATTAGE SERVICE SERVICE WAT-TAGE —WASTAGE SERVICE SERVICE �� WA-T TAG — � "ATTAGE SERVIC uIR DESCRIPTION _ �tA dB C BKR Ai3C BKR �,A �r8 C DESC:RIPTION CI CIR C� E3KR �` ABC 8KR E :! BKR AFC �3KR DESCRIPTION OA OB O C. !6A 09 0 C DESCRIPTION CIF? DE`aC:RIFTION 0A 0E3 0 C �.A $B M :' DESCRIPT )N 1 800 1 2Q 8a0 LIGHTING 2 1 JUKE BOX 503 500 ?_0 L 2G 540 GFI RECE_PTS 2 RECEPTACLE 600 2� 1 1 2Q 0a PHONE: SYSTEM 2 LIGHTING 20 # 3 LIGHTING 68Q 20 1 1 20 650 LIGHTING 4 .3 SPARE - 20 1 2U 936 REF. WORKTABLE "02 4 3 RECEPTACLES 1000 20 '• 1 20 1548 ICE MACHINE #1 14 4 _ # 5 TRACK LIGHTING 11200 2.0 1 1 20 600 LIGHTING 6 5 REF. PIZZA TABLE #104 1200 20 .1 + 20 310 SOUP WARMER #103 6 5 1 TV/VCF? 500 20 1 - 1 20 - SPARE -��—_^ 6 W.�. SEE NOTE #1 7 EMER. LIGHT. & EXITS 12.00 20 1 1 20 1200 TRACK LIGHTING 8 7 PRINTER #403 200 20 1 2 � 310 - 8 FREEZER #109 `960 ' 20 1 f i 20 ��- SPARE i3 9 LIGHTING 400 20 1 1 20 12001 TRACK LIGHTING 10 9 SPARE 1 20 1 20 1 310 SOUP WARMER #103 10 9 FRYER CONTROLS #1 1 , 200 30 1000 WALK IN FREEZER COND. 10 i 1 EXTERIOR SIGN 1000 2U 1 1 20 - SPARE 12 1 1 PRINTER #403 200 20_ 1 9 _ 310 12 1 ? MICROPHONE #512: - _ _-- rzp0 20 1 1000 - 12 !� 13 SPARE - 14 13 ERMINAL 402 200 20 1 t. — _ 20 1 1 2G SPARE T # 20 1440 REF SAND. UNIT 102A 14 SEE --•-- 13 FACP 5UC1 20 1 :3 1 Q00 14 � � 15 SPARE - 20 1 1 20 SPARE 15 PRINTER #403 200 20 1 NOTE 1 i_ --- - -- } 30 1000 WALK IN COOLER CONO 16 16 20 SPARE 16 # 155 SPARE _ 20 } \ �►, 17 SPARE _ _ _ 20 1 1 20 SPARE 18 17 TERMINAL #402 200 20 1 ; 20 _ 400 MENU BOARD #1 15 18 17 SPAGHETTI COOKER #120 -.._ __.. 360 20 1 1000 - 18 ? ;' 19 SPARE _ _ 2p 1 1 ?_0 - SPARE 20 19 PRINTER #4Q3 200 20 1 1 20 660 SODA SYSTEM #125 20 19 T•ERMINAt 402 - 2.00 20 1 �� 4 1000 + - 20 21 SPARE _ - 20 1 20 SPARE ?2 21 SLICE WARMER 119 1680 20 1 - 1 20 1200 HAND DRYER 502 22 21 TERMINAL 4C2 __- 200 20 1 20 - SPARE # # - 23 SPARE - 20 1 1 20 - SPARE 24 23 U.C. REFRIG. #1021B 1 480 20 1 1 20 12001 HAND DRYER J502 24 23 TERMINAL #402 200 2C 1 1 20 _ 500 VIDEO GAME #525 24 ' � *� "z� +; el i25 SPARE - 20 1 1 20 - SPARE 26 25 FRUTOPIA DISPLAY #107 200 20 1 1 20 50C WATER FILTER SYS. #139 L6 2S STAND BY POWER #40F 200 - -- 20 1 20 500 VIDEO {,A►.4F #525 2 6 "' 27 SPARE - 20 1 1 20 - SPARE 28 27 COFFEE BREWER #1 12 3125 40 1 20 1200 MICROWAVE #1 16 28 27 SPARE _ 20 1 - 1 20 24O p BEVERAGE MERCH. #130(2 28 C? ,� ft 29 SPARE - 20 1 1 20 - SPARE 30 29 - 3125 2 1 20 20C PRINTER #403 30 2y PROCESSOf? #4U4 ZUO 20 1 1 20 _ 500 VIDEO GAME #525 30 31 SPARE - 20 1 1 20 ISPARE 321 31 SODA MACHINE #110 750 20 1 1 20 360 REC. ROOF 32 31 PIZZA OVEN CONTROLS 35e W 20 1 1 20 `,)OQ VIDEO GAME #525 32 33 SPARE - 20 1 1 20 - SPARE 34 33 WATER NEATER 200 20 1 1 20 200 _ PRINTER #403 34 33 COOLER ETVAP �— - '000 20 i 1 20 '20 EXHAUST HOOD #136 34 $ 35 SPARE - 20 1 1 20 SPARE 36 35 SLICER 147 500 20 1 20 650 EF--2 36 35 FREEZER EVAP 1.000 20 l 1 20 1 1000 EF-1 36 37 SPARE y 20 1 1 20 SPARE 38 37 EF_3 mlt 830 20 1 650 - 38 37 MUA---1 :300 . 20 ` � 20 6Ut, EXHAUST HOOD #137 38 39 SPARE _ 20 1 1 20 - SPARE 40 39 LTG HEAT IN FREEZER 1000 20 1 3 650 40 39 _ �_�� 300 600 - _ 40 41 SPARE - 20 1 1 20 _ SPARE 42 41 SPARE 20 1 20 - SPARE r 42 41 -- -�_3a0 .3 3 600 � 42 TOTALS PHASE A = 4000 TOTALS PHASE A = 7340 _ _ _-_ _ TOTALS PHASE A = 7210 PHASE B = 2930 PHASE B - 10516 PHASE B = 8008 .r� kA OF� PHASE C = 2800 PHASE C 8775 PHASE C - ;660 y TOTAL CONNECTED LOAD = 9730 TOTAL_ CONNECTED LOAD = 2.6631 _ TOTAL CONNECTED LOAD = 22878 _ _ _ PAY1,9 ELEGAL PANEL BOARD NOTES: No. 1. PROVIDE LOCK FOR C/B. f o g9a,�`��/STEP�a��e 2. E.C. TO VERIFY REQUIRED RATING OF BRANCH CIRCUIT BREAKER �S3�ONALE 3. ALL LIGHTING CIRCUIT BREAKERS SHALL BE "SWD" TYPE. 4. ALL EQUIPMENT MOUNTED UNDER THE HOOD SHALL HAVE SHUNT TRIP BREAKERS. 5. ALL PANELS SHALL BE SQUARE "D". ALL PANELS SHALL HAVE BOLTED ON BREAKERS I . LIGHTING 9730 0 1007, = 9730 FIR_ ALARM NOTES: 2. RECEPTACLES 4200 0 100% = 4200 - � < 3 HVAC LOAD 37800 ® 100% 37800 1 ALL WORK SHALL COMPLY WITH LATEST FIRE DEPARTMENT RULES :2 AND REGULATIONS 4 KITCHEN FOOD EQUIPMENT 36129 ® 65% = 23484 0 CA 2 ALL WIRING SHALL BE CLASS "A". INSTALL WIRING IN MINIMUM 1/2" , CONDUIT. 5. MISC. 4800 0 100% = , 4800 '--` Z 3 HORN/LIGHT UNITS SHALL BE 4-WIRE TYPE. WIRE HORN AND LIGHT 6. WATER HEATER 200 1 50% = 100 d.- Z UNITS SEPARATLY TO ALLOW FOR HORN SILENCING WHILE LIGHTS 7. SIGN. 1400 100% = 1, � �J 'Q REMAIN FLASHING 400 4. ALL WIRING SHALL COMPLY WITH MANUFACTURERS WIRING SCHEMATICS. TOTAL DEMAND = 81184 WATTS 5. VERIFY EXACT QUANTITIES WITH FLOOR PLAN. 82 KW® 120/208V, 30 228 AMPS 6. ROOF TOP UNITS SHALL SHUT OFF AUTOMATICALLY IN ANY FIRE ALARM CONDITION. � tt r—MAIN ELECTRICAL PAPA GINO'S -----i- ROOM _ 400A M.L.O. F F F F VOLTS 480 2 7 MAINS t PHASE -7- PANEL SCHEDULE BUSSING 4 OA WIRE 4 FEED 4 50 MCM n. A.I. �. 10,000 PANEL "MDP" MOUNTING SURFACE SERVICE WATTAGE .IVATTAGE SERVICE _ -: BKRCIR DESCRIPTION BKR AE3 OA 06 d DESCRIPTION CI B 0C TO OTHER DEVICE 1 AC-1 5520 100 4000 PANEL LP 2 4-500MCM,#3G,3 1/2"C �FL_—,1'FZ� (TYPICAL) 3 - 55.20 r 2930 -� 4 METER SOCKET & AC--1 AC-2 �J L�J CANSUL SYSTEM CONTROL PANEL - -- C/T CABINET SG SD 5 5520 3 3 2800 - �� --( AC--2 5520 60 200 7-40 _ PANEL PPI 8 4#3/0,#6G,2"t: R R R R 9 5520 051 10 M A ? A T 11 - 5520 3 3 . 8775 -- 12 — i "LP" "PF'1" "PP2" 13 SPARE 20 200 7210 PANEL PP2 14 SPARE' 100A 200A 200A 15 20 1 � 8008 - 16 " FACP MDP" MCB MCB MCB � M _ ---- -- LOCATE ADJACENT —7( 1 SPA ____ 20 1 - 3 766C - 18 �.m.l TO PANEL_ J 4#14, 1"C RIGID STEEL CONDUIT 19 ;PARE c,,J 1 SPACE 20 TO EXISTING MALL FIRE .ALARM CONTROL C/T j APPROX MATANELY 60'0 ROMD NEW FACP ry 1 SPARE �_ - 20 1 - SPARE 22 400/400/3 FIRE ALARM % 2 z SPARE 20 3 � SPACE 24 4#2,#8G,1--1/4"C CONTROL PANEL --i IN EXISTING MAIN ELECTRIC ROOM �'�' --� TOTALS PHASE A = 29590 • PP2--13 — — PHASE a = 32494 86 — TAP EXISTING CONDUCTORS -- --------- _ - IN EXISTING WIREWAY PHASE C = 30275 4-500MCM,#3G,3 1/2"C - TOTAL CONNECTED LOAD = 92359 FIRE Al ARM RISER DIAGRAM < NOT TO SCALE W ?I < _ NEW POWER ONE - LINE DIAGRAM FIRE ALARM ZONE SCHEDULE ZONE DESCRIPTION 1 PULLSTATIONS _ RF 2 ANSUL SYTEM __ _�---- DATE 10--7-199 _ 3 DUCT SMOKE: DETECTOR SC ALL E 4 SMOKE DETECTORS CAD Fit-E 5 SPARE G.` J08S FAPACING 9817C -Q1 6 v SPARE 100 NO --- SHEET Building _.� Engineering Resources, Inc I E - 4 TEL:(508) 230-0260 Shovel Shop Square FAX- (508) 230-0265 28 Madn Strut, Bldg, 3 BER7207@A0L-00TN No. Easton. \1A 02,356 NU. !�E'VISI(Y6 DATE UP 6"to TYPE "B" FLUE 8"0 EXH FLUE UP FRORO 14" EXH DUCT TO HOOD TRANS TO UP THRU ROOF -- FROM HOOD NUMBER 1 F�2 ON ROOF 00 INTEGRATED WITH PIZZA OVEN OFFSET AND UP EF ---- 16"x 12" SA DUCT UP FROM { TO EF-,3 ON ROOF ---- - - --- HOOD OFFSET & TRANS TO 6"x6" CEILING \' FAN UP TO ROOF ,\ ON ROOF 14 A-1 ON ROOF '; f CAP ON ROOF EXHAUST HOOD #2 ; c f _-.. _ T - --•. i I o I i --- - = �__._..__ 1125 ♦� II � 20"x10" I 4 10"x 10" 14"x 1 2" 18"x 1 18"x 1 4" ' A f 20"x 14 I ! ------ -'�-------� j " - - "0 :,:4 to - I! CEILING FAN I I -- 1 1 MUA 11 D- e25 � I 1 _ � QC126) 0 D— I I ON ROOF III -- ANSUL`) " ---1-------------1----� CABINET 3 350 2U x20 SA UP ? - _-- - - _^--- ---- _ -- - I T ,- IZZIV TRANS TO AQ- lr -1� ( i 14X48 ! ON R00E-_- __. - ._ r 00 11_ ,I lL. !J r - - _ � • 20"x16' RA UPr'- i!!I1' D- TRANS TO AC�2 2 I �axs <"4x if, _ ++ )) ON ROOF------ ON ROOF -_ . 300 isk t -- T t r -_p- + t _x _x r,-4 q; � 314" Qr �—, _ 1 N ROOF _ - -- -- f __._ _ - z��---- --_ _._ ._ ° -- - -- _ _ __ __._ _� G I _ TEVEC J ac 1U � 10 � 10 A. tKARAN - ,� 5,1,-1 MECHANICAL CD No ,4939 cf) -- {t _1 _- a Ln __ 6 I! AC �"� 20 x l �_:- -` ! =�. F ION ROOF r,= { _ D t 320 L 20"x 16" RA UP 20"x2O" SA UP TRANS TO A -1 TRANS TO AC_1 �, ON ROOF C( N OF� 10 i i 12"x10„ I I 0 RO t, ) _ � _.._. 0 _` N i 20`x10 1��.,o i 1 I eD 75U f 320 Q (i G- J Cl. ON ROOF ♦ I ♦ I� '8 x j� �0 x12„ L i 750 .. 8„ ER-1 f 300 8"x8" , g"xg' 200 _ ` 1. f 10"x10" EXH UP O TO ON ROOF FLOOR PLAN -- MECHANICAL ! f 1 I SCALE: 114'4 J'�9 I i i I I ,l EXHAUST HOOD SCHEDULE A. J MARK y: M �.F SIZE: MANUFACTURER ANC) MODEL. REMARK:' HOOD #1 700 -- INTEGRAL PART OF PIZZA OVEN 0 -f- WITH ANSUL. SYSTEM & HOOD #2 2343 1640 9' -0"x4'-0"x2'--0" GREENHECK GHFW-9 HOOD MOUNTED CONTROLS J 1. INTERLOCK ANSUL SYSTEM WITH BUILDING FIRE ALARM AND TO SHUT DOWN GAS AND ALL ROOFTOP UNITS AND FANS. 2. HOOD EXHAUST FANS AND MAKE-UP AIR UNITS TO OPERATE BY LOCAL WALL SWITCH. Q U VENT1[_A1'10N SCHEDULE- Z Q EXHAUST 'X)T000R SUPPLY RETURN UNI1 SERVICE AIR AIR AIR AIR U TOILET 500 - c M EF-2 PASTA HOOD 2,343 - - EF-3 PIZZA HOOD 700 - - - ()RA1NN FCA E_F-4 LAVATORY 100 APPR. MOR DATE 10-09-1998 AC-1 DINING - 750 3,000 2,250 r. A(:- 2 LOUNGE - 750 3,000 2 250 SCALE t 4" = 1'-0" .. DINING CAD FILE MAU- 1 KITCHEN - 1,640 1,640 H: PAPAGINO 98199 _T NO. 98066 fOTAIS - 3,643 3,140 7,640 4„`i00 SHEET Building Engllleerlllg Resources, I nc. "I EL:(508) 230-0260 Shovel Shots Square F�AV (508) 230-0265 28 Main Street, Bldg. ;3A BER7207@AOL.CONI No. Easton, MA 02, NO 6"0 TYPE "B" FLUE VENT 2 ROOF CAP W �` .; 4 * •4 oil _�y a EF s laud Ac �� 2 EF 3 R j XAAAAOF Al el STEVEN KARAN MECHANICAL «® ® No. 4939 is E4�`J '�• a /0 (�AC V) 'Q Z N cri � M Z CL Lj Q EF < h-- 1 lL w L�1 t n. t I r C, ra t o ROOF PLAN - MECHANICAL SCALE, 114'-T--O' Z Q C.l... Lam... 0 Of Q ?PAWN FCA WPR. MOR DATE 10--09-1998 SCALE 1 .4M r. 1"-0- CAD FIL H:\PAPAGINO\98199 .KGB NU 98066 SH ET:r Building Engineering Resources, I roc. rLL:(508) 2:3(1--0260 shovel shop �-)q uare FAX (508) 230 0265 28 Main Streei, Bldg. 3A BLR7207@AOL.C'OM No. Lasto n, MA 02356 _ i "W1"1"fl,»p1H1YlY"Ctlu'..YM/II�� F' , NO. REVISIONS DATE DIFFUSER, REGISTER & GRILLE SCHEDULE __ PACKAGFD ROOFTOP DX AIR HANDLING UNIT G ------ -� - - SYMBO r ' f m %CK MATERt L ;YPf �JAtitPEP, OVE�tAt 1 RE1�bRK`; AL ._EGF __ I RANGE sltr: _ MECHANIC _ND EVAPORATOR FAN HEATING (W,) _ _ FLICTRICAL 9ATA _ f1F'ER. TRANS UNIT SERVICE LOCATION -�� TOTAL TOTAL MOTOR '0 At.. TOT:A! NO EER ~� WT. MODEL NUMBER D-1 _ 0. 1( '0 1LLJM+NUM + f3AF OBD 3 24"xd'4" METAL AIRE 5000 SYMBOL ABBR. DESCRIPTION TOTAL MIN. E.S.P. AMB FNT ENT CLG. SENS. DRIVE RPM MLTI! MBH CONTROL VULTS�PHASE HZ M.C.A. M.. S. TLBS.) S 6 ! -- ----,_�-_-- N0. CFM O.A. (IN.) .F 'Fdb Fwb (MOH) (►iBH) TYPE N.P (INPL!'r ( )t`TT'UT) STEPS (a5 STANDARD) _._.� ___ "- SD-2 101--200 8"al } ALiI�A`Nl h� 1 _ i OBD Z4"x?4" METAL AIRE 5000 RECTANGULAR DUCTWORK OR BREECHING a " 1 '> 5 166 2 9.0 :208 5 60 46.0 60.0 800 YCD09OC3 __ ___� __- ____� ___v AC-1 DINING ROOF 2700 fi75 0.50 90' 8O' 6T 90.6 63.0 BELT 725 � 40a - i SD--3 201-400 10"1 ALUMINUM T-BAR 060 24"x24" METAL MIRE 5000 --AC-2 KITCHEN ROOF 2700 675 0.50" 90' 80' 6T 906 630 BELT 1725 2 205 166 7 9.0 208 ROUND PIPING OR DUCTWORK 3 60 46.0 60.0 800 YCD09OC3 � -- - I RG-1 750 18"x 18" ALUMINUM T-BAR 24%2.4" METAL AIRE CC5 ROUND FLEXIBLE DUCTWORK NOTES; 1 . PROVIDE AC--1 & AC-2 W/ LOW AMBIENT COOLING, ECONOMIZER W/ RELIEF, INSULATED ROOF CURB, ELECTRONIC PROGRAMMABLE THERMOSTAT, AND SHORT CYCLE PROTECTION. � , - 2. PROVIDE WITH DUCT SMOKE DETECTOR INTERLOCKED WITH AC TO SHUT UNIT ON SENSING SMOKE. SMOKE DETECTOR SHALL HAVE CONTACT FOR REMOTE ALARM INDICATION. ! RG-2 1125 20"x2O" ALUMINUM T-BAR 24"x24" METH a.IR1 CC5 --rG-� RECTANGULAR TO ROUND TRANSITION z �+ L � - " +7r-'t ER-I 200 10"x1o" ALUMINUM T-BAR 12X2 METAL AIRE RH SUPPLY DUCT RISE & DROP�I a ` 3 t 0"x toll ALUMINUM T-BAR 12"x t 2" ME J TAL AIRE RH 00 lOLUME/BA,ANCING DAMPER a - -I t- Men (1 ooQ) Btun MAKE-UP AIR UNIT SCHEDULE UNfi SP OUTSIDE ELECTRICAL. DATA HEATING (MBH) OPER ;.P. STATIC PRESSURE o MANUFACTURER WT, REMARKS BDD BACKDRAFT DAMPER No. AND MODEL CFM INCHES AIR HP. (INCHES) U PH HZ INPUT OUTPUT (LBS.) OSA OUTSIDE AIR 140 1 2 2O$ 3 60 150 118.5 850 PROVIDE WITH ROOF CURB RA ! RETURN AIR { MUA-1 KSU 110 B-2-5 1640 5 6 / A MOUNTING LEGS 7i SA ` SUPPLY AIR ,. EXH EXHAUST A/C ABOVE CEILING AFF ABOVE FINISHED FLOOR SD SUPPLY DIFFUSER FAN SCHEDULE ER EXHAUST REGISTER IT ELECTRICAL FAN FAN - ! GREENHi (X - OPER. -- UN SERVICE LOCATION CFIrI FAN E.S.P MOTOR MODEL NUMBER WI. REMARKS ---� VD VOLUME DAMPER vd y, VOLT RR RETURN REGISTER ,c. S(G,WE A. c n� NQ. TYPE (IN. W.G.) PH HZ RPM BHP HP AS STANDARD (LDS.) ` `�'� EF-1 TOILETS ROOF 500 UPBiAST 375 115 i 60 1400 .08 1/4 CUBE-95-4 52 PROVIDE EN FACTORY AFJ CURE BIROSCREEN do B,ACKDRAFT DAMPER � MECHANICAL ��13A� THERMOSTAT ( Iv IAECHAt�E EF-2 GRILLE & PASTA ROOF 2343 UPBLAST 1.50 208 3 60 1410 1,22 1 1/2 CUBE-180HP-15 103 do PROVIDE W! FACTORY CURB VENTED i 3 �9 EXTENSION CURB GREASE TROUGH S� S�I DUCT MOUNTED SMOKE DETECTOR I ����©�, ROOF 700 UPBIAST 1.25 1 i 5 60 86Q PROVIDE W,/ FACTORY CURB VENTED EF-3 PIZZA .29 1/3 CUBE-- 60 EXTENSION CURB GREASE TROUGH TROUGH -- NOTES: EF-4 LAVATORY CEILING 1()o CEILING 1.25 115 1 60 1450 - 37 WATTS SP-108 121_ � 1, COORDINATE ROOFTOP UNIT LOCATIONS AND ROOF OPENINGS WITH ARCHITECTURAL AND STRUCTURAL PLANS. 2. ROOFTOP UNITS TO BE ACOUSTICALLY ISOLATED FOR VIBRATION AND -NOISE. DUCTWORK (SUPPLY & RETURN) TO BE ACOUSTICALLY LINED. SECURE ALL LEADING EDGES IN DIRECTION OF AIR STREAM. {f) Q 0 I (NOTE ALL BOLT, SCREW, ETC., CONNECTIONS Z N vi ROOFTOP UNIT (SEE PLANS FOR LOCATION) TO ROOF DR ROOF CURB T4 BE WATERTIGHT.) M _ f k Z 20 RUBBER EXHAUST FAN (SEE PLANS) 13- W „� NAILER & SHEAR - 1 ��- g < }" >- STRIP ISOLATORS EXHAUST 1" NONCOMBUSTIBLE DUCT 22 GAUGE GALVANIZED - COUNTER- ROOFING FELT SPACER SEE DETAIL SHEET METAL ELECT. CONN TO MOTOR -� ! s FLASHING FLEX CONNECTION r CANT STRIP 16 GAUGE WELDED CARBON � THRtl BREATHER T1,1BE � 40" MIN, 18 GAUGE --_ STEEL GREASE EXHAUST DUCT GALVANIZED - - 1"L.x1/2"DLA. NONCOMBUSTIBLE DISCONNECT DISCHARGE ROOFING SPACER, (SUCH AS STACKED EXTERNAL DISC __-____ HEIGHT GALVANIZED ACOUSTICAL LINING - �- MATERIAL SCREW WASHERS,SMALLER DIAMETER SWITCH (UNDER ELEC. �� GREASE TROUGH (PROVIDEL) u C3 CURB m - TUBING OR ELECTRICAL SECTION) _"" a ' WITH FAN) I ," AIR SPACE I CONDUIT.) ATTACH FAN TO EXTENSION ..- NT ALL METAL cuRa W METAL SCREws__/ I EX ED o SUPPLY & RETURN ROOF ! 1" THICK MINERAL ; / �. / EXTENSION ROOF CURB DUCT (SEE PLANS) WOOL BAIT INSULATION MIN. 2 EA. SIDE (BY MECHANICAL CONTRACTOR) - TIGHT SEAL W/ - _ - SQUEEZE _ �. _ __ COLLAR 1/2"x1/2" WIRE MLSH LAG BOLT PRE-FAB 24 1 -24"X24" METAL PAN FILLED RIGID -� ACOUSTIC a Ns VENTED CURB TO WOOD _-� � � f � MATERIAL � � WITH SAND ON GREASE TRAP INSULATION ACOUST. BOARD OR NON ---- CURB MIN, ?. EA_ SLOE SIDE OF FAN PROVIDE 1" DRYING CAULK AROUND DUCT (ALL AROUND) -- TYPE "X" GYPL3ARD NOTE, DRAIN HOLE WITH SCREEN ___ ,"x 1" ANGLE SPACER WELDED CANT STRIP '"r' IN PAN) 1. LINE ROOF UNDER CURB AND SIDES OF CURB WITH 4" TRICK TO EXHAUST DUCT TO I (BY ROOF CONTR.) (TWO 2" LAYERS) ACOUSTICAL BOARD. MAINTAIN I" AIR SPACE -ROOF INSULATION _-� BLOCKING (BY 2. ROOFCURB TO PITCH 1I4" PER FOOT IN DIRECTION OF ROOF P!?CH ��; 2 LAYERS OF 1-1/2" "FIREMASTER" FIRE WRAP MAY BE .-._.. TO PROVIDE A LEVEL ROOF TOP UNIT. USED TO CREATE 2 HOUR RATING IN LIEU OF MATERIALS SHOWN. FACTORY ROOF CURB 3" MIN. ROOFING CONTRACTOR) , (BY MECH CONTR.) CLEARANCE -� EXH. DUCT SEE FLOOR PLAN I EXIST. ROOF STRUCTURE FOR SIZE, 16 GAGE SHEET L ROOFTOP UNIT MOUNTING W/CURB GREASE EXHAUST DUCT FIRE WRAP DETAIL METAL MIN., W/CONIINUOUS Q NOT TO SCALE NO SGOd.F FIRE WRAP EXHAUST DUCT W/ GREASE TIGHT WELD OR F- P$EEEHBEQ ALIIRNATE ' ALTERNAff ` A_L RNA MINERAL WOOL BATT - / BRAZE ON THE EXTERNAL CT SURFACE. TAKE-!OFF FIT TING - TAKE-OFF FITTINC TAKE-OFT FTTTING TAKE--OFF FITTING INSULATION (RATED A 120o'F) ONSTRUCTION S(HALLTMM Q DUCT HOLE SIZE MINIMUM` -_ N.F.P.A. 96) SIZE DUCT HEIGHT ALL ROUND AND RECTANGULAR OPTIONAL FEATURES SHALL STANDARD 45' 6x4 7.56.5 7.5 BELLMOUTH FITTINGS SHALL ;NCLUDE THE FOLLOWING. BELLMOUTH BELLMOUTH MINI-BELLMOUTH RECTANGULAR TO 86 FITTING MODEL MODEL ESMD ;ONNECTIUN AIR >, ROUND BOAT KITCHEN EXHAUST- FAN MOUNTING DEC-AIL 10x4 11 5x5.5 7.5 BE INCLUDED WITH THE FOL- NO SCALE 16x4 17.5x5.5 7.5 LOWING STANDARD FEATURES: 1. 26 GAUGE GALVANIZED BMD WITH END FLAPS MODEL MEMO FLOW CONNECTION 24x4 25.5x5.5 T5 QUANDRANT VOLUME DAMPER BENT OVER MODEL. 3300D CONNECTIONS 6x5 7.5x6.5 8.5 1. NEOPRENE GASKET TO T NOTE: ALL BOLT, SCREW, O B WATWATERTIGHT) WIT TIGHT FffTING GASKETING 10x5 11.54.5 8.5 MINIMIZE AIR LEAKAGE. TO MINIMIZE LEAKAGE AT - R TO ROOF OR ROOF CURB TO BE WATERTIGHT) 16x5 17.5x6.5 8.5 2. PRE-DRILLED HOLES DAMPER PIVOT POINT-. 24x5 25.5x6.5 &5 FOR QUICK MOUNTING. 2. HEAVY DUTY HARDWARE IS ROOFTOP EXHAUST FAN D 6xAVAILABLE FOR APPLICATIONS VD VD VD VD (SEE PLANS) ( - 3. CONSTRUCTED OF HEAVY 1Ox6 11.5x7.5 9.5 WITH INCREASED STATIC Q IE 16x6 17.5x7.5 9.5 DUTY GALVANIZED STEEL PRESSURE. { I 24x6 25.5x7.5 9r5 $ 13lROSCREEN (PROVIDE W% EXHAUST FAN) -- 8x8 9.5x9.5 11.5 l 16x8 17.5x9.5 11.5 �BEEERREQ ALTER BRANCH �N' BEAK-H ., FLASHING AND COUNTER- 25.Sx9.5 11.5 TAKE--OFF FIT'1TING TAKE-OFF FITTING � . 48 11.5x .5 11.5 CONNECT FAN TO CURB W 1 � FLASHING BY ROOFING �.� 1 x1 17.5x11.5 13.5 P PERKED T NAT CT MINIMUM DUCT �� MINIMUM DUCT HOLE MINIMUM 3/4" LONG SHEET METAL --.- -- - w CONTRACTOR I DU HOLE SCREWS, 12 Q.C. (MIN. 24x 10 25.5x 11.5 13.5 RECTANGULAR AIR 45 REG ANGULAR I DUCT DUCT DUCT  CANT STRIP B'( 1 -/r• I SIZE SIZE SIZE SIZE SIZE SIZE OF 2 PER SIDE ) � _ _ ( -- BEL_LMOUTH FLOW TAKE--OFF I HEIGHT HEIGHT HEIGHT c `.. ROOFING CONTRACTOR; FITTING MODEL 5" $" 9" 5" - - 5" 5*x1O" 7" L RBMD 6" 9" toll 6" 7" 9" 6" 6"x 12" 8" $ FACTORY ROOF CURB r jc 7" loll 11" 7" - - 1" 6`x 12" 8" (BY MECH. CONTRACTOR) - ;; ROOFING CONTRAC?QR I 6 w r 8 9 ,�1 8» » • 6.5»x12" 8.5• I ,� RO DRA�y " , FCA 8 11r 12 9" 12" 13" 9" -- - 9" 6.5"x 14" 8.5" r' nryr" " " I c MOR 10 13 14 10 11 13 1 . x . I 12" 15" 16" 12" - - 12" 8.5"x18" 12" ROOF !NSULATION r ATIE 10-09-1998 VD V0 � 14" 17" t$" 14" - - 14" 10"x20" 10.5` r I EXISTING ROOF DECK ,CAS-I: 1 4.' �}RAN�H 1 BACKDRAFT DAMPER ALTERNATE FITTINGS TO BE USED WHEN DUCT HEIGHT (PROVIDE W/ EXHAUST FAN) CAD F:LE DOES NOT PERMIT THE USE OF THE FULL SIZE BELLMOLITH. - EXHAUST DUCT (SEE PLANS) F+:\PAPAGINU' 98199 �... OR h0 9808b ALTERNATE RECTANGULAR BRANCH DUCT TAKE-OFF I ALTERNATE ROUND BRANCH DUCT TAKE---OFF EXHAUST FAN MCUNT!NG DETAIL S No a:-i. NO SCALE NO SCALE Building; .�..� - Engineering Resources, I nc TIT.:(508) 230-0260 Shovel Stoop Square FAX: 608) 230-0265 28 'Main Street. Bid . 3' BE R72070A OL..COM No. E.a.Sto ri, MA Q2, 'i6 m ♦ R. .. .. ..: .e:... ., -77 3. I A r�rrw�rr� ^rri 70REVII-SIONS DATE r_ 1 5EGTiON 15500 - HEATiN6 VB'f'iTiLATIN& AND AIR ,C NDI T IONjll G 'volume Dampers I Furnish and instal; :mess otherwise noted !n specific situations complete control 3: �,P[-RATIW, ANi? MAINTFNAWE INSTRIaCTIC'16 nts tern cis e�fied herein, and as shown air; Tie plans The em c;ornparnc� sys �.` � t, p ,ygt PART ; - GET�KAL I Furnish and install manual dyers ,ureic indicated on the drawings and where shop include ail trrrrr ;stets 3ensur, ontro!lGrs,dariper nisei damper actuators am A prior to ,orrretior of the ;.ontrort, provide field and writtsh operation] instructions tc the owner's required. Dampers sholi be riot less then Lew 9cluges heavier than ductwork n rticr other occeseor+ey re+ired a:x c,-:rvote iristai!otion. and electrical Work lily,00ntrAi C.Essi teci representative with respect to erotion Pvnctiony and maintenance �rocecaxes for ----�-- - I PE'5GRIPTION OF WCiFK installad. All dampers shall et provided With ai juatmsnt gvaarants and locKing r c + o! , ' p °p r t`; tins ape c+tivr a< the vvn,xo stem. Power siavrco. wi' be prOvldtsd � the all equpment ;aria systems Ir+stailad ce.vie-es lin accessible locations Provide at all branch take'--offs and of ;,,!I Electrical 5iiAxontractor as 3 ec!ftea nearer `U tam 3ha'i irk;; i �''Pe''a p !� vde oil ha drlpr a t0 A Work Included. Provide iabor,moteriois and equilrnent necessary to complete the work of this take-offs to each diffuser svpp and return. ate as specified. rooralirolte r tr c.hiiior, boiler curder*ote receiver and _aie. "� pier 8. Ali operating equiprnert PtSGaiied ;rider tl1i5 section shall be pieced ;n operation aua shag! Section, including but not limited to the Work indicated on the drawings hand" unit mcxxufacturers control �t�rrw Pro loo—, midentof wir of : rel function ccmthuousl n an I� +� - � ��"' y operating test for a period of throe days, without shutdown due .o D. Duct Access Door, as nee®scary achan+ca! failure or necess(ty of adjustment. Prior to scheduling the product Final inspection 2 REbt!(.ATORY REQUIRE' NT_. and after completion cif oil instoiiatlon and running equipment and avtvmat!c contra I Furnish and nstali access dears rrhe3re spoa tied whore indic.atea or the drawnagr B Wirna ^•cajustment5 pee-form or balancing and any liner .work -egunred to p;oce the equrment r A Comply with all applicable federal aria state Tail and all local codes,bye-laws and ordinances. and Wnere reoiured to perrr•it inspection and maintenance armp,ete >perotw condition to meet all requireme,nts anise• ttllls speGiPfGcatkun During this I. Furnish and nstoli ail eiect:r!ca now including kntoriccr, and control wiring necessary -.,n.nirq test period, deliver to the C,esgv, two complete sets of operatioq, seance mantenon<.._, B eihere provisions of the Contract Documents conflict with erns codes, rules or regulations the E. Flexlbie Conrtecticne for the control tom and smoke detector Interface wr -stir the HVAC tnit and r tAGemerit data for ail t which wlil r ng ep eqt 1prion squire .Rferat+r>vj mar,ter acre or 99 utter shalt govorr. Y#1ere the contract requirements are in excess of applicable codes, ivies operation Any step down+ voltage transformers shall be rtrnished. All nteriock wirng roploceme•nt ;and one repo of this lheratvr�e "ji be a•.ailat>!e during the instruction of the. W �f or regulations, the contract provlsIl sholi govern unless the Architect rules otherwise Flexible connections shall be installed where indicated on the dr^owinas. The flexible shall be provided this Contractor 'he Wirt and race stom shall ! to J r. r - by miring "� sy y operating personnel while the _the is :hacked for compietonesa ny the L esig er Pt ng ail cornecttonis sholi be vent-glass constructed of naoprane coated type as the e6quiramants of "NEC' and electricol section 6000 of these specifications wvrkna hours of the "operat,rKj tZ5t tins C,ontroctor's personnel shall, rx, available for giving field l rm C "vast inspections From authorities having jurisdiction, obtain all permits end pay for all fees manufactured t,� Vantfabries, Inc, or approved equoi. The flexible e,onneetiorts 51i ll nstruction shall cover operation,-rainteril end adjustment of oil equipment installed and Inspection certificates as applicable and/or required All permits and certificates shall be be tightly secured with metal bands. A minill 4 Inch spore ono a I Inch stack shall G. Power Sources by Electrical Contractor a ' turned over to the Owners at the complet!or+ of the Work be allowed For the flexible connection and the connection shall not be stretched ti r �'t .. Operating Manual Upon completing rise work,provide the owner with ropes of the approved A flexions connection shalt be installed on the suction and discharge connection of air i Ail po%_r wing between the starters and the Try AG equf vrnt motors mall be operating manual containing approved shop Drawings equipment literature, cuts bulletins, 3 SUBMITTALS handling units rind exhaust fans provided by the Electrcco! Contractor All nec au essary xi!kr`j contacts in the rewred performance Criots and details equipment and engineering dc+to Btwet5 and 4"mr,tte^ conPlgration M the magnetic starters shall also be prnvlded ioy Electrical C.ontraetr,)r instructions •eicitive to the care and operation of thR O ®r ' A. Refer to Cionorol Provisicns for requirements. F Duct 5eaing with information pro v ided by this Contractor B. Provide shop drawings For Rooftop Air handing units, Fans,Unit Heaters Dvctwork I. Furnish and install duct sealant at all seams joints and duct carrnectiore. D Dampers 33 HOl5T1Nb, SCAF�OLD!N6 5"AbINFr AND PLANk INb l c. staardads, ►;angers and Supports, Dlffusoro i Grilles,Controls, 'Naives. maximum 0110MOble, duct Ietak09M shall be 5%, of the rorspective system total air I All automatic dampers shai! be of new leakage type,designed to ensure it& lockage A Provide; set-vp .aid maintain or -equ;red derricks, hoisting machinery, scaffolds and stogir,g, 1.4 COORDINATION quantity in the closed position shall not exceed 1% of normal Cru �A 4' static pre53vre pionl,,ri and perform all hoisting required to complete the work of this Filed Sub-Bid as i differential across the damper Dampers shall have inflatable seal neopresne str-il- ncilcoted and specified. (I A pork shall be performed in cooperation with other trades on the project and so scheduied ml CG. Prato Cooker H000 secured to blade edges, ard shall have spring Upe statniai 5tee zero clearance to allow spec and efficient completion of the ill rxe"Ure plate For seor'g rise blol ends 5WWs sho'l bP nterio<,king and cf B 5coffold6 shall have solid backs aid floors to prevent dropping materials `Mere From to thG fio�rs I. Provde aluminum duct at Pasta a4 aust, pitched to drain back to the ,T.pose-d blade Ve. Damper blades shall not exceed 6" in width and shall lire or ground B. iF" HVAC work has been Installed before coardhotion with other trades so as to cause hood. Pasco exhaust duct sha'I ire 3eoleci watertight frabricated from tW0 sheets OF •22G golvan!zed stee spot welded for corrugated interference with the work of such trades,ail necessary adjustments and corrections shall be c„�nstruction Shafts shall be not Tess than I/2' diameter biases rot' and sholi be 3.4 T'E5T146 AND BALANCING .. made by the RVAC trades nvo!ved without extra cost to the on ne•es H K.ltchen hoods through bolted to frame: Bearnge shall be Nlon or ollite Any outdoor or leakage d;,rN system shut down shall not be acceptable Damper fral shadl be of 13 A Total system balance sholi be performed ir au ordance with AABC *national 5tandords fc- Field G. Protect all materials and work of other trades from damage which may be caused by the HVAG I Provide 18 gauge molded black ron retailed per N''A 116, insulated or Trapped to Ivarado sheet metal with flanges, for duct Mointin Al; automatic control M a. work, and repair all without extra cost to the owners �"� � d"9e g easurement And Instrumentation,total System Balance or A:,HRAE - i �4 systems damages maintain a 2 hour rating or provide Jan-Packer grease duct, 2 hour rated dampers shall be provided taco this Contractor Hcr>Cbook Provide full balancing of air and water systems t !5 MECHANICAL AND ELEGTRIGAL C,00RDiNATION ®®ed'A"t®� 3 REGi5Tt3t5,6RILi_E5,AND DIFFUSERS 2 Dampers shoo the factory fcbr;caa arid shall be built in multiple sections, with g Provide the fallowrug: ®��51A OF P4 ;Ail, tt secretions not tc exceed 48" in alther d n&*ior Each section of Ib sq ft area or y�`� 15 A Heaths, Ventilating,and Air conditioning 5ulacontractor shall furnish and install various electrical A Register's, grilles and diffusers shall be of aiumirnrm construction In the mode; size ark: copse:to smOiler shall have o separate operator which shall have a minimum spring return Before comrnencirnc) work, verify that systOMS ere campiete and Operable Ersi+re the f�a STEVEN A. n ,kr items relating to the HVAG equipment and control apparatus 'no Electrical Subcontractor shall schoduled on the Dram. Equipirnortt shall be as manufactured by Metal-Ara or rat a ai to 'S4 odditionai area to ensure ti t caosure at+cns shall be f ! s htAr AN rt9 4' �r o lo"no - ", 9' be reavlred to connect power wiring to this equipment unless noted otherwise. Tuttle and Bailey,. Finish to be selected by the Architect secured to the damper frame Damper sections shall not Ina !ntariocked ir any way MECHAN AL With the adjacent sections The contractor snoii coordinate the carper cstallation a Equipr,ent is oporan;e and in a safe and normal condition N 34 B. All power wiring and Iotal disconnect swltcnes Will bo provided by the Electrical 5vbcontractor B. All registers,grilles and diffusors shall tie furnished with Individually odjvatabie opposea r.)1c)o3 with the Shoot Metal Contractor, and shall inspect each damper for proper operation y�'U STE �Y°s for the !ire oltage. power All control and interlocking wiring shall be,, the resporsiblilty of the volume control dumpers. Winer+ Installed All potential air leak sources shi<ill be plugged tad.; dine. HVAG b Temperature control systerns are installed complete and operable 01ML. Nay°'i� NVAC 1_vbcontroctor Contractor ♦rr.�� G Provide square to round transitions +-snare, required c Proper thermal overload protection Is in piaca for electrical equipment G 124V pow s power wring source extended ona corrected to heating and veriiotng control panels, ° Leakage and flow chcracteristK.s charts of dampers shall be submitted for approval. transformers and switches shall be the responsbll"ty of the Elactrlcol 5wcor&octor. All low 24 INSULATION d. Final filters are clean and In place If required, ir3td! t44Vororu rnedla In voltage thermostat, zone valve and iris snitch Wring shall be the responsbW4 of the HVAC E Damper beratorb addition to final filters Subcontractor A 6,orieral i Ali cximper ;oper..1tOrs shall GO olectr!c,proportional 0,- i pcsitw CIS roa ad v7 nine o. Duct syatoms ere clean of debris lib IN5TALLATICN REQUIREMENTS i Ali sealers, solvents, tapes,adhesives and most►cs used o conN,nctlon with the epe,:�Iloct sequen e. They shall be quiet In operation and snail hove ampie purer to installation of oll insulation specified au:ler this section of the specifications shall overcome fricton of damper linkage and air pressure acing on lowers tc position F Correct fan rotation. A. The arrangement of all HVAC work shown on the drawings is diagrammatic only and indicates possess the moximirn pcb5bie fire-safe dualities available axed shall be of a taWo as dampers occuratoiy and smoothly The damper operator mountng ;: roiyjement V) �Qc the minimum requirements of the work Coniltlil at the bulldnq ncluding actual approved under Ill' all be aide the air stream Wherever possble 9 Fire and volume dampers are n place and ope-: rneosurerr,ents shalt determtne the details of the nstailotion. Insulation Ono jacketing, seo"ers topes,adhesives, mastics and other accessories G. TKermostots'Devices h Access doors are cioseo and duct end caps are in place Z N '7 RECORD DRAWIN65, PRO.ECT GLO5EOVr used n conjunction With the installation of insulation shall have a fire hcazara rating of � M �_ not to exceed 25 for Florio spread and 50 for smoke developed A.o material shoii be i !provide thermostats for unit heaters and Electrical Room Motorized Darrpar t Ar outlets are Installed mply and coxrnected � Z A. Co With Requirements of General Provisicris. of ts�es approved ureter NFPA W U OA, xderwriter$ Laboratories and by insurance Z 1.8 6UA carder H. 5equence of Operation j. Duct system leakage has been mnlmized. < Z 3. Insulation jackets and facings i Rooftop Units 2 Report any defects or deficiencies notea during perfornxxnce of servkes to the < F— A Ali rbw materials, iteime or equipment and Workmanship Fix-riished under this section shall carry L Q W X esigner standard Warranty against ail defects in rnaterid and workmanship for a period of not less than a. Ali jackets and facings shall comply with the Fire Hazard Ratings a. Unit shall operate on occupied/unoccupied mode by action from thermostat one !I) your from the dote of final acceptance of work Any fault due to defective or improper time clock 3 Prcrriptly report abnormal conditions in mechanicai systems or conditionns wtilch material. equipment, Workmanship or Manufacturing design whtch may develop Within that b. Vapor Barrier ,lockets and Facings prevent system balance period shall too made good forthwith,by and at the expense of this Contractor. Including all b occupied mode: Jnit shall Gy(le heatirng cOOling on demaid to satisfy other detnages done to areas,materials and other systems resulting from this failure 1) All v barriers shall be souled and continuous throughout tp shall allow Free 4. f. for design reasons, system cannot roe property balanced, re-Or: us Boor -As o 0 spa 9hO1J sensor and thermostat: se outs Economizer control cooling when outside an is suitable Outdoor air dampers shall be fully modulating obser,-ea B Tf,is Contractor shall guorartea that all new elements of the systems meet the spe.ifled 2) All voids shall sae filled With insulating cement pror to appiynal {� performance reavlremorts as sot forth neren or xs indicated on the drawing vapor barrier jackets. c. unoccupied mode- Unit shall be off Unit shall cycio to Maintain night-set-back :nooting only,;, 5. Beginning of work matins o:.ceptance of existing conditions A Warm-vp cycle shall be programmed to start prior to opening outside air damoerc for 1.11 QUALITY A55URANCE 3) No staples shall be used In vapor barrier jackets. occupied mode b Prov de additional L-410XN devices as required. d Provide duct iimoke detector nterlock for tam shut-down A 'fie requirements of the iotal regulations astoblish the minimum acceptable quality of 4. Insulate all concealed ductwork and all piping. Adjust workmanshp and materials,mad all worK shall conform thereto unless more stri nt Adjust or handing systems to plus or minus 5 percent for supply systems and plus ^9e Kitchen snood Exhaust, or minus 10 parcont For return and exticiust systems from figures indicated rrn ° rogvireortts are ndicated or specified by the Contract Doumnents. B. Ductwork a 5tptems shall start/stop marvoi switch control mounted on hood. (Intarlock Make-Up e Recoroea data shall represent actually nneaeu-ed, or observed condition B. Protect all w,brtk materials,and equipment from damage during process of work. Replace a;I I. Unless otherwise xnacified ,n specific areas nsuiate all concealed supply and return Air Uri t with associated exhaust fans) damaged or defective work,materials and equpment without additional cost to Owner ducts and old ovtJoor air ductwork(combustion air ductwork) throughout the project 4 After adjustment, to+.e mExasurernonts to verify balance haas not been disrupted or that With ! ivh Chick f berglas9 Faced Duct Y1'ap(with vapor barrier) with factory applied 3 Pasta Cooker Hood such disruption has h+ee r r�ctiflei: a C. Keep the interior of all ductwork free From du9t and dirt until the duct syatoms are r" For flame retardant Foil-Ranforced Kraft Facing (FRK-25 UL. Icbetedl Sound !had operation Supply air system shall not be operated unless a full complement of the specified portion of the ductwork shall not be externally Insulated a System shall star4stop bg remote switch 10 Leave systems n proper working ord.5r replacing belt guards closing access doors, roughrg and prehiters is in place to protect each supply system to be operated f- i eosins doors .,r electricai switch boxes cma restoring the mostrats to specified 2 insulation shall be strapped tightly on the ductwom with all circumferential fonts setter �.. s D. An! item this contractor proposes as an alternate or svmtitutnon shall be submitted for approval. butted aid iongitudinol joints overlapped a minimum of 2' Any added costs such as larger fuses,gas piping,wiring, supporting steel, etc shall be paid by 4. Toilet Exhaust. II At final inspection, recheck random selections of data rocoraed in report Roche i,, this contractor. Any field coordination required for a subst!tution is the rosponsolhty of this 3. Kitchan 'grease exhaust ductil shall be Wrapped in a UL Listed 2 hour fire wrap M „ points or areas as selected and witnessed by the Owner. contractor a. For shall operate by wall switch, 2 pole 4 Ali across doors shall roman occassibio and shall not be concealed or obstructed Cy i2 Aaiust air handling and distribution systems to pre,.ic�� regwred or design; supply PART 2 - PRCJDUCT5 ir�sulatlon. roarr,ax'l exhaust air quantities ?1 PANS 2.1 Rooftop Air Handling Units C Internal Ductwork Lining 13. Make air quantity measurements in ducts by Picot tube traverse of ent+re cross A. Provide rooftop fans and curbs as lhdtcatod on the schedule and details. Kitchen axlx"t Fans se('tlonal area or duct ~� A. Provide packaged rooftop PA or handling units With gas Fred heating section, insulated roof curb, 1. Insvkate all rectangular ar handling unit supply and return ductwork for lO feet past shall be N14 waded construction,grease tkjnt. •C. . t programmable, thermostat. economizer and power exhaust lover 6 tons/, On leak dampers first elbow or to first transition Insulation shall be I Inch Ill polyoil iF5 or IR5 !a Measure air t Quantities at air mats and outlets a Weatherproof enclosure, two inch filers, internal spring isolation, coll grid, irsu{ption kit, 2,8 MAKE-OF UNIT , disconnect !note that roof opening for roof cub Is for 5A ! RA ducts only,not entire curb size) 2. Insulation shall be "ho Ito; aide ine nO r' With fiber lass. insulation shall be UL161 ` � `� g _ Adjust distribution system to obtain unifaXrr, space terfperawres free from B Provide nterbGK miringbetween air hall unit,and thermostat Whore indicated or. dry listed,meat NFPA smoke/f°sine spread I^9 n9 A. Provide a gas Erred ma crop all unit a5 indicated on the sGheduies �vvde fan, goy heat objecttcranlc rarafts ana noise A Provide progrommiable thermostat with time clock,night set back, economizer exchanger,curb,controls with duct dischage temperature controller 3 Adhere insulation to ductwork with IMGOA Teat-ti t seai�ait gin 16 Use volume control devices to regulate or :,I;ranutiet onig to extent that odjustments C. Compressors shall have crank case heater, internal over'oods Refrigerant circuits shall have do not create objectiorncbie air motion or spina ;evens Effect volume control bg suet orifice expansion devices,service ports filter drier. 25 GHIM7�1 AND BREEGHlN6 PART 3 - E)TGUTION intern} devices such as aanpers D Units shall tie Trane, ;ar er or York A Independent vent (ch and breechn tem for domestic hot Water `m rasp � krrney `y � 31 TESTING AND ..LCnSECXlT !i. ✓any total system car duattttles by adjustanernt of fan speeds Provide -1r,ve �:hange5 M� heater shall be so engineered and constructed as to develop a positive flow, adequote to re red. VAr tarAnch air entities damper re nation ms 22 SHEET METAL WORK exhaust all flule space to outside atmosphere,Without corndensatipn withri the vent or spillage A All Idtchon axhaust/make-up syste sh tali be tested underting Full load opera conditions.at ml� y oppl le Measure static air A. Lon Pressure Ductwork Goordnate wain the owner far systernn testing doing owners initial training period for full kitchen pressure conditions on air supply units, including filter and toll F; W egvipnnent cooking load slrrvlattor pressure drops: and total pressure across the for. Make ailoml for 50 percent A, B All parts of vent system shall be of Lnderwp'itar's Laboratories, lnc. listed ttgfae Ph or IP5 per loadn3 of fitters id I. 6otvanized steel sheets,reinforcing andrrp cvanlon anegies hangars metal manufacturers recommendations All shall be contnuovs fro breeching g the into vent top as B. Cieaning k Specifications gouges and construction of seams,joints and reinforcing shall be manufactured N NV.ta"bestos, Van Packer, AMPGO,Metal Fab or equni 19 Adjust outside air outomotic domwers, oiutsiaa air, return or and exhaust dampvers for according to the latest 5MACNA Publication - `HVAC duct corntrvcrtion standards" I. Upon completion oil shoetmetai work specified under this 5ectbn is to be cleaned. design conditions C 4ion the chirnety is installed accord to its ns bn instructions an limitations o toliattrtid the limitatif its � All equipment is to be cle<:rnGd all trim nsta;iea all protec.tive oil. tape or other 2. All reactcr4ylcr sheet defined ce all ductwork,unless otherwise specified,shall be nisting,it shall comply With national safety standards, NFPA 211 and building codes of the local materials used to protect m0rK are to Ida removed. 20, Mecol temperature conditions across outside air, return air atct exhaust dampers constructed with Pittsburgh Ian hAdhol seems. Transverse joints shall be mode up Town t State of Massachusetts ✓z n to check i0.ow:uae F CA With pocket locks and corner closures Changes to sae shall; be made With a tapered 2 Ail ducts, fas. and equipment shah be thoro"yiy cleated inside axi outside and connectlon approved by the Architect ix�t shall In no case exceed 30 degrees to the D All exposed metal parts shell be protected a minimum of ors base and ono Finish coat of 2 APPR. wIC1k iaiown out t0 prevent cmy debris from dtameagimg far ehleids or debris �rgng tirL7ugh BdlarnGP. kltcfnen equipment I.xder provisions a:tlined in 31 dxve I" of air FloW pant,such as 'Series 4200--4300 hoot resistant pant as manufactured O9 Rust-Oleum re istears or diffusers when customs ere laced an operation. Ai! to x 9� p "�` y DATE i0-09. 1948 Corrporotlon,or equal. Part shall toe supplied and applied by the Installingcontracts �• omec icx>a required for blowing put the systems cheesecloth for ail duct Gfaenngs, $ Flexible, Duct and any other equipment or labor for 0owlinq small be provided b4 the H•,iAi;, SCALE E Stack and broaching shall ve of the typa listed above. install system as recomimendod bg :;oritract,)r The entire HVAC system shall be kept coon until final accoptance Any i 4" _ 1 —0" i Furnish and instoli, where shown on the drawings, Iresulatod fie (bie duct Flexible mcnufactaurar with 45o take-offs,Wall supports and guides,drain aNvneetlon,axpansiorn joint and aam. to eei!i s thin HVo+C Carntraetor shall sae rectified him np odd,tianna; END C 5ECTi(A CAD frIJ- duct is ailowod only above dropped ;;,,el!ing support assembly- :incise to the Owner. to the 3ati5fpct:or of the ✓e3iarner H. PAP AGING 98199 ;�>E+ N(i 2. Flaxble duct shall be fabricated of steel helix spring With aluminum laminate :finer F Breeching shall be adequately supported from the buildirntj strvct,re 3 9805E 'zsplace U'li filters n a!I air handing �.nits and for ar coil units prior to final acceptance fgberglaas insulation and poly,,nyl jacket. [[� S. Provide sepaate shop drawings showineg the complete lay-out of ail breeching and flue duct and the C.wrner. B U l d ing SHEET 3. Flexible duct shall be suitable for velocities up to 5500 FPM and stet;c pressures up ail corvnections and accassories for approval prior to nstollotion. to 10 inches hf.b. Engineering AUTOMATIC TEMPf�zATt� ;;,ONTROI. RE'S011t't'eS, �I1C.4. Care shall tie taken that all ifexble duct eomectians ere installed c7s straight as rlv;i � ° possible and fastened to avoid air leakage or darxage. Maximum flexible duct run A. beneral 141, shall be 5 fact I'LL:(508) 230-0260 Shovel Shup Square F'AX: (508) 230-0265 28 Main Street, Bldg, 3A BER72071PAOL.COM No. Easton, NtA 02356 No. REVISIONS^ M, QA z 00 A • Q r •, - i 1 w v O d O O I 4 a -v © O DRY TYPE SPRINKLER HEADS — — i I O vI i - - - + �_ h STEVEN A. n 5ry' ' qpp MECHAN6CAL A is ter. y- 1 .. — _ • /' ��v��� f • ,11 I • -_ _. ... _ it-1 .. -. O Z N • - r Z O a O 4 O i Cl. Li <C O 0 FL'wOR PLAN - SPRINKLER 9c&E: 1/4'-r--0' SRINKLER HEAD LOCATION 5/16 IN DRILL-IN STRUCTURAL EXPANSION ANCHOR V RETURN BEND DROP TO CONCRETE FILL MINIMUM SPRINKLER HEAD IN CEILING C 7. ---- • "�i 11. _ CEIUNG CL ACCEPTABLE HERE -- STRUCTURAL -^� DO NOT LOCATE SPRINKLERS / 414 iy STANDARD 2X4 CONCRETE "THIN THIS AREA. ( + CEILING TILE STEEL DECK STEEL STRAP <NA>S1' WIDE X 2' LONG ---•� X 12 GA, MINIMUM / TOP OF SIDEWALL SPRINKLER BRACING HARE - 4 TIGHT TURNS --� DEFLECTOR ACCEPTA�.E HERE / �3�f•- SPLAYED SEISMIC 2: 4' BRACING HARE -� 4I • ••••� r SPRINKLER HEAD LOCATION INSULATION OVER STEEL DECK STEEL STRAP - tCL SCOREUNf SPRINKLER BRANCH PIPING SIDEWALL HEADS LISTED FOR If BELOW CEILING ( 'T ----- MAY BE NSTALLED PERT. • �� 1"X 1/2" REDUCER iv SCORED 2X4 � CEILING w\ �' -• FINISH CEILING CEILING TILE i CLIP BRACING WIRE - / .,"/ \ •' L 2-1rB X 1/2' V �- �CEILING TILE E AS SPECIFIED HW U TED IN / aRF�44 � VERTICALAP PR. SCREWS PPING HANGER LA NUiE• DATE 1p 09 1998 ' REFER T17 SPECIFICATION SECTION 15300 FOR STEEL STRAPS --� SCREWS ,_ WIRE 4' i 3' WIDE X 4' LONG SPRINKLER HEAD TYPES AND LOCATION SIDE WALL r X 12 GA. SPLAYED SEISMIC REQUIREMENTS WITHIN CEILING TILES. BRACING WARE / SCALE 1 40 = 1,-0' LOCATION OF SPRINKLER TYPICAL CONCEALED SPRINKLER HEAD CAC? FILE HEADS IN CEILING PANELS NTS 2 SEISMIC CABLE RESTRAINT ATTACHMENTS 3 RETURN BEND DROP NTS � LOCATION OF SPRINKLERS AT WALLS NTS H:\PAPAGINO\98199 NO Building 98066 SHEET Englileerill Resources, I nc,. TLL: (W8) 230-0260 Shovei Stu, ,�uare FAX: (508) 230-0265 28 Main Street, Bldg. 3� A BER72070AOL.COM No. Easton, MA 02356 = N0. REVISIONS DATE ENERAL REVISION 11/18/98 SRINKI_ER HEAD LOCATION _ 5/16 IN. DRILL-IN - - STRUCTURAL — EXFANJION ANCHOR 1' RETURN BEND DROP TO CONCRETE FILL MINIMUM SPRINKLER HEAD IN CEILING CEILING ACCEPTABLE HERE - ti kill �4 z STRUCTURAL �C, I DO NOT LOCATE SPRINKLERS w Q STANDARD 2x4 CONCRETE WITHIN THIS AREA- 4 .7 CEILING T11 E / _ \- L � _ STLLL 'DECK - STEEL STRAP NAC � e t V WIDE X 2' LONGTOP/ I • �r i X 12 GA. MINIMUM fLER ' _ DEFLEOCTOR ACCEPTABLE F SIDEWALL KHERE %!� I ' BRACING WIRE 4 TIGHT TURN ---- ;%�`. -- SPLAYED SEISMIC I 4 BRACING WIRE ---- SPHINK.LER HEAD LOC,A IION INSULATION OVER STFFL_ DECK STEEL STRAP -- — SCOREL_INE - SPRINKLER BRANCH PIPING SIDEWALL HEADS LISTED i td OR 12" BELOW CEILING 0 FO R / MAY BE INSTALLED HERE \i / 1 "X 112' REDUCER SCORED 2x4 _ - __ n n ` f % _. _ . _ . . _.- CEILING �— FINISH CFILTNG CLIP CEILING TILE __�_ ,--_-.- _______ . � BRACING WIRE -- --- SPRINKLER HEAD I OCATED IN 1_ 2 CEILING TILE AS SPECIFIED f. , �►XkAAA 2-#8 X 1/�, VERTICAL '7 i ®� NOTE; ,°., M,1s CELF - TAPPING HANGLk \- A v REFER TO SPECIFICATION SECTION 15300 FOR . 5 �yv STEEL STRAPS SCREWS WIRE SPRINKLER HEAD TYPES AND LOCATION SIDE WALL STEVENA. 3" WIDE X 4' LONG --- 4' SPLAYED SEISMIC e .3AN REQUIREMENTS WITHIN CEILING TILES. X lc GA BRACING WIRE 1 ' Psi o 4 lag L LUCATIvN OF SPRINKLER TYPICAL CONGEALED SPRINKLER H �_A<L` SEISMIC CAR[._ E RESTRAINT ATTACHMENTS 4- LOCATION OF SPRINKLERS AT WALLS ~��v� \ l F ( NTS HEADS IN CEILING P.Ai�iEL� NTS NTS ,.� RETURN BEND DROP NTs U7 Q w O C14 ^ M LL W Q n< F-/ � w V J CK z W a .j cl C> z C-7 rn r' cn : - DRAWN P13 APPR. LAW r _DATE t U-09-1998 --'— SCALE 1/4" = V-0" CAD FILE ; H:\PAPAGINO\98199 JOB N0. 98066 ----- __-.----- -- ---- SHEET E_udding DWIEngineering Resources, Avl�� TEL: (508) 230-52Wel Shop Squar� �'"■ I FFAX 508) 230-0860a!ri 'Street, Bli BER7207@AOL.CONNo. Easton, MA 02 • r ,< < • : , p : . ,s. ,. x n : ,:'., + . a _ .,. y. .. a e ., , i : .. , .,. , S., '- ,. .. , o- . I:. . .c :. ,. t: , .. a.: : . a.. s .. orww+.un,.s.,w.+a.r.•�sa>w,r•n•,b,.,r..pw,,,w+ .nsa.«rvz•w-.Kna-v.w„n«w:+.....�navmr:cw.:c.wswru a,w• e,-a::uw+ms.+;n�s�,.<wwae...a•.+e�m,,,>na,.•a�•x•..-m°. a�:,..:wwr,.,wa+e,m.:•,.:»„w-w,.,,«,ro,-:w.n,n,m...•wse,..+nvw.ux..+,n.»w.ar:•,w,_..wnw�m ,x=wwe..r,.wwa•..w.s:w"c:=,wr+e " �.+�,°eras.Fiw.+abrexe,.Irvvwa.me E 4,.a..auna•ataAncrenw.,sw. rrwrw.na+ni.•:.r wm.�.wv,�.x�'enr.:w:„,w.v�n+.n•r•..a,+,yt .e rr*aMfiaw'+sd'pemst+__ __- -.:var,... _,M«•. ,_,...:..,.«,+.,- ,,.r.>.....,...,.s.. ..:.,..w...„+.-«.•,.=.«.ar,.mr.;« :w,+w,w,._,,:..w:>..anr)+.,w.rcnn,+r+n.ws+w,r-.w,w+nrar«,.,mar;».+.,..w,+„r,,.rax<w,r.,x,e<, :rrol,"..a,..,, *.u...csw.we - -*,xw*an,..+.a+,-.w,.«,wmr+...- p, .•.:.•.t-,.w•--w.wr.o�»-e,....Hh..,.,a:.,w.a..:,•r+rr. -_ 'g J ray °�S d� r Y., a, , : x. '..I • .... ,, ,:.. .. .. r ,. a . d :. , ,: ..r : - ..et.,. -.., :. e - t. , , .. , r h a. , _ _ . 1 '�a :. t ., L ,. ,. , �. Y ., •: s 2. , ,, • .. „ I , <� ., rt w : a- r .. s . .. I , tF .-. a ,> ... . K , .'Y , -,. ...., :. -., a _.,.. , `: 9 .: p g [ 1 c .. Y.. , ,. r ,.. .r /n R .,... ,, , c ,. t r, ..,::,. ,,1. , _. .� s : x G.. a ^,n Y- ,: , d. _: .. 3,.. ,. .' .. ,. .. ..,.. ... ,,: �'� ,..,.✓ 'A. r. ,.. Y , �5 .. ., ,.._ h :. , ..., r R ,y , :''� a .•.. i. . A' , .. .. a. ,. : .Yv. 1 .. 4' , ,... ... 1. .. 7t� .4... .. !• % .- r. - ,. ,. s ♦ y .. ,. ; r ., _ ,I ... ..d.. .M ,.. J f w, ,. 4 � �, �. �� fi , �,,,_y ", I , ,& � I � , I ,:: x k zt�., ," .. .. 'rd' r .a /. cl x. - ".". I I . IA sr - .f.., ,, t -. .,-. , , .,:. I ,� , ,. ,,� I �" 1. . . : ryy� r ♦ 2 ", + �I , t- ., ,'.: ..e. , ,. a ,: I I I - < ._ , ..p yam' .. , .1. , �. r �. .. .,., e, , ,. ..I a �:' , ., ., a ...'?p, .,a u "d ., .. a•- . , - ..�„ ... w. a ..:-_. .. ,+. '« ... ,. ... a .,. zr, ." ,. ., -, �.. .. .... ., ,__ "I I .. .. „ .. •, .. >, Yn' ;9 , .. -:,, v<,f.r ram. , ':L i x s Y. R u _, rev ,,, , ,. ., j ,r; +,. . ..ryq, . .: .. : ,s ,,,. yy r t 44 ,: ,. ., p . 11 d A,, .; ✓ , 1 IW WATER � �, K {�'2 FROM W ON cat R.SE t # 4 d . HEATER TO POP S NK , i f� d . `.� ^�„ '� UN da( Ft15F `101 a„ W !�A � V RISE Y1 1) .�. k .F�. TOILET RC EXISTING `_� ;"'`� � !-3: N" DN 11 0I ,�—. 2" V DN &: RISE (FE '�. . w- TO REMAIN. d GREASE T � SEE QETAIL �3N P- 3} ,/ " 'a DN & RISE (FD) rt It I �., .. 1fItTL, .Ir.l! .AM iBYI lam, YYF '.��I 1�f •� l�Ii ��r �N iA�! �l �R >19�!t!P -'�F� hCM� 'lY�xt 'J[!'!K ,IBItl1b: Ml9Gr,.. *OYIkM YMM illlrl� �_� Yv�,,,� .r4 } 8 k95 a sow a r� .,,�. nTama ylll#':,,. � i`.9,', �• ,h•.`+n ,6,'.q/0 j,.� ••i.. ,�Y9�xa ,. w+^r t1lvn.- 1+ .� �• ril .Irl� �� -!Y 1rB .A Irl! Imo. : MI! AWri ,Fwe.Y g,, ' S' , , ..,. ._.�. ,�..r.�.�...,.-.,»....M..-.,r..v."rw.-._ ..-w r.w w........�..,-..r..i..r,. .,..�...... -.._.. ..,,,. .1u. .-,,,_,,, .._.)r }S, , : , iii '444 ^7ro:M•d' �f-TA:.-'-.+,4., .,rt. - .,L. .::., w+,f' ,,,..w::tin,,,.,-..._«:,,.-_,.,..�...-... 'R ,Ig t i .Ij" d- , 1. _. Y* 4 4 wo , .�•"".,• t t r .x :1^C." r. "'l"=. _ , -"n ,;. ': ;.. I ,y.."*r `'. 1+ ^- i r V t `. '3 ; -J I ird» �! .ems mom am � � �` � -3" � �� �•, �� �# v l -� 1 -1„ 'x ;i iii 4##!���::°��� tltltl 1f ,� "1 1 _ r . . g TR It ! - r 6, r ' „ lye (10 1l# �:F >,L� ,� � :,i, €1' , _. - _ . , _ ,r e; � I / ,** ,,, � I I I I. I . I h�- -w ,: 1� " , , r. _ _. �J, "i `d� d�ott �* �f� �( ��._ • z. I ij jr2,?.i. irtf 4 <'' IUIU NEW �" GREASE. �. i1 i tt I �. _ Y__ ___. - i 1 1 .�,Al.l �f GREBE ..k ... .�.. ! 1 , it Y".,? a_' , - { 1 vr.,R91' E,XAC i..C3t., f;(?N a ##v A ,._. w _ , '_ } .. �,,ni.;(ttit?,t.#y'a+ ��htpt{14f411.;. .. Ti 1' t '.F°I i1'�,{.�. �: i! -3g �,. .L-, ! !;! I:a'.I1''t }.-i: ,I!t4 f V, ��`' ,tkj;t; 4 !' �� ®9'Ga�� ���i1 I ._ , R T ` a121 I TS W E� •! .. , .._.." ..,I t. iftnl + ,' , 1 ' 1:.� t .x�y '!' 7 `J ,v"I f , ,,...I.. , i !,:i„.!:4,it:i + , �j' 1'{!.�•{ 1- r I µs,,ir t. _ i Ii' Ga < �° � �� d`1 t tt r z 4 I h t, m,w F"p. .:.<:,gin _ , � f+� ,r .,I,'. �ak°�wr :--"""`.,� C LL! F�� z 4�j cin R3„, v x + 0>y� �� ..,• A fp, ° , �P1 P400 e�� G I a ���s®srs I , i _ _ .a.,.1. i , ; :� ! I � W DN & V RISE ,,�I � 'i � _ t2# A S GN a , 2" V DN SE (WO ; 4" VTH 1, .r } w rp I� �liR) i '✓ b t V Dh do RISE (IJR t�l t , :_� . 4 11" 2" V DN & RISE I D > a , � �,, RISE (FB ` r d � ll ' _-_. -- »=-- • ,�". °1 D#4 dt ROSE WC P . — DN 1 E ( �._:._ �, - - - j i Lj'. ,---'-,--,— . . i . . I . 11 I a- Lj _< 4 ,, .` Qom„ d 1 1 _—� � . L _. :_ . ___ -- ,� •,a,: -,.,,.. ..�.,., ram., ;.,,. >,.,,, ;r, '" ...,,. . _ __ .F... ,,.,I:, _ �... .x.., .,,d.. �., — — — — — •:. +.ram � �,. : _. -•,... ,.-F� �,b� �I� — . — ..r, , . ,..un ,,r — wmi . , ,� ,.. — .._ .A. 1 � �t 7 ,- , ... , } . — r '. , CONNEC7 TG EXISTING t3ANffAfrf �° 5 x », WITH EA' 4" S !t# ARY VERIFY '� `' ;% 1. �� r:X fit'+ AT#{)t� !N FIELD, FRAME & COVER IN FULL h—___\ 8RICK, (2) COURSES j:1__Um,fL_--J0J.�jr �� ! �� MORTAR BEt7- 1�?lCAL. i ~•� _. _ _ __ ____._._ ._..._.... .__._. „�_..__.__ 1tlk�NtMtld+�-TY4�'tCAI �. ?♦ 1TIDES EXISTING -"k. ___ _.__.__ __. --- -._. -___. __ _ _ -� TO PVVA W, i a,,- �it�� 'l� 1 y 4 r GNlAI#NF_Y C1f SEWFi? ..•........ .. , BRICK, (2) COURSES .._ ," ; _'. _ I11 " L " ` as _�..r,.�..._— .�,.�r,�.....,{:,, .*1�-�.r;�.f.�_,�.; ,•,M.*..�,,�.,�,,�„�.m,,..,m._ _���...,.�,. �� ___.�..,� ,, t r� ,.,..�._ _. BEN � �. f T I _.._�.r. �,_.._:.. ___��_ ,_ .. ....._........_._._.,_-�.•..._____.--_. ______._,_ _�,_a.._. 1 ,. ,[� tG t _, 1 f ,-1" OEMTL * _ `' vim` ! .3 . �,. , ,, TtiTtC:f3T SEAL i '' x � I I I >A' �)1�0"c iGS `ram i .,..•,..a f n C�,,� YERS, OF WA .a - �„ r W ON �e...r 4/ 11 i L...'r ( i J► t 1 :,,•�f � b € } • ' a t d '�,.r% �f A . { t M . I n , T r.,s @Q t. • V ,��. fT�sl,+r.. ��7 _ .. '3..k I: 1* -w ;r tt,�yam^ a,a�'� .�, 1..4:.s!$..,{,,.It'd; 1 r.Ae d -: fr �- s ✓,' .. ".' .r r/ ,', r ?r , 'r ' rY ': •.iP .- F a ..... ..... .W..,. .-�. ...-I,«.....,w...•.r.-.. ,_... _...-...W-_...,•.� d --.r.•.....�,•,.,.�...•.-_ �._,...�.-,_.__,,.•�,__ ..._.. - _.._a— a''AR' i..JR�i�ii` c ! !7+ —f"{4CMi i TJ - "_. # i("' 1,,,,fi� 1 4.J !_11 -�f"S, 1 1at f} � ���+� LL •.-•.,.-. _.._ _.r_s__. #•;>pAFAG 98199 i, ,......�..,. SHEET d ..• "' Engineering L{_,:{;,i}Fe, �:j{�-fiE ; ftd,�cl :�tjd;aa (teiaYe F A 'i= �t?'1 % f i t) i: strzi rt t 8 itsg�:SA }�[IX720 a�0L,tO*v! No, ! t�,:�'ld,tii, MA c)a`Tiii . . ::, .. .., ..:,,., y - rN0jREVISIONS i7A TE 1/2" HW DROP 504) 1/2" HW DROP " 1 1 1/2" CW DROP 504 1/2" CW DROP 111 1/2" HW DROP 111 1/2" HW DROP 120 1 2" CW DROP 1 1 1 3/4" G DROP (120) 1" CW DROP (510) 1/2" HW DROP 106 12" CW DROP 120 1/2" 140' RISE (510) / ( ) 3/4" 1 i 5' RISE (510) 1/2 CW DROP (106 1�2 FCW DN TOILET ROOM EXISTING 1/2" 140' DROP (101) 1 G DROP (141) TO REMAIN. —1/2 CW DROP (101) ,� w '` rs „ " ------------ -—- - - ------ -- --FCW-- 1�r- -�_ ..�.- ------ ------- FCW--- - - - - - - ---- ----FCW -- �. - �, _� ' _ ? , A _ROOF G�+' ---�� - -- / / � I I 1 2 1 2" 1 2 I 2" G UP TO MUA-1 1 -1/2" 2 _ „ ( ON ROOF 3/4 , 1 1 3/4" _ 2" 2 G UP TO 1 I 2" G UP TO 2_1/2" � AC-t AC-2 L" STEVE.N A. x li 1111/1 K iRAN C t§ 111... -.441 NIE1'i a"iAMd.AL hJn.aril a` rL . ...... , . AC __--.----- ----z- ION ROOF I 1/2" FCW RISE (139) All ' -+ ......�... .,.,.�„- 3" �. 1/2" CW DROP (139) �--'-----`---- _J 0 C� M CONNECT TO EXISTING COLD Z WATER WITH NEW 1" CW. 3„ CW DROP 3/4" HW DROP W VERIFY EXACT LOCATION IN COLD WATER -- Q_ < FIELD. IN CHASE Q >- WC_2 WC- dr TOILET ROOM EXISTING PLUMBING - WATER PLAN _ TO REMAIN. SCALS 114'-1'-V r - - _ _ -i 1 I 1 1 L ... .� .._ ._ ..1 1. CONNECT DORMONT SUPR-SAFE GAS BALL VALVE TO HOUSE OAS LOADS O�O PIPING. (AN ADDITIONAL STEEL ELBOW MAY BE NECESSARY DEPENDING ON THE LOCATION OF THE HOUSE PIPING.) COOKING: PIZZA OVEN = 300MBH 2. CONNECT THE MALE END OF THE SUPR-SWIVEL FITTING TO PASTA COOKER =: 77.5MBH O � � THE GAS BALL VALVE. FRYER = 1 10MBH < - ' U� MBH ,,,,,_„� 3. CONNECT DORMONT SUPR-SAFE GAS APPLIANCE CONNECTOR GRIDDLE = 7 5 r� O (MALE ADAPTER) TO THE FEMALE END OF THE SWIVEL FITTING. TOTAL 562.5MBH (NOTE-DO NOT USE PIPE DOPE , TEFLON TAPE OR ANY OTHER HEATING: 0 SEALING COMPOUND IN FLARE SEAT OF GACONNECTOR.)S AC-1 = 205MBH 0 O ® AC-2 = 205MBH I/ 4. JOIN FURNISHED STEEL ELBOW TO APPLIANCE NIPPLE. ELBOW MUA = 150MBH 0 SHOULD BE FACING DOWNWARD, WATER HEATER = 75MBH TOTAL. = 635MBH 5. ATTACH SUPR-QUIK QUICK DISCONNECT (NIPPLE PORTION) TO STEEL ELBOW. TOTAL GAS LOAD 1197.5MBH 6, CONNECT BOTH PORTIONS OF SUPR-QUIK QUICK DISCONNECT DEVICES (NIPPLE & COUPLER) TO SUPR-SAFE GAS CONNECTOR. TIGHTEN ALL CONNECTIONS. PERFORM LEAK. TEST WIYH LEAK TEST SOLUTIONS , IMPORTANT: LEAK T-EST SOLUTIONS MAY CAUSE CORROSION-WATER RINSE AFTER TEST , THEN DRY THOROULY 7. RESTRAINING CABLE AND MOUNTING HARDWARE: APP �„A,vr A. RESTRAINING CABLE LENGTH MUST BE SHORTER THAN GAS DATE 10-09 1998 i CONNECTOR. B. ATTACH THE STAPLE BRACKET TO A STUD IN THE WALL. SCAtF t ,4., 1._4" C. ATTACH EYE BOLT TO THE EQUIPMENT, D. ATTACH SPRING HOOKS OF RESTRAINING CABLE TO EYELET CAD FILE FASTENERS ON WALL AND EQUIPMENT. H: PAPAGiNo .�8199 NO, 98066 SHEET Building LfIgineenno Resources, hw. 11L: t`;6 2:it)-W'A,)u Shuvei Shup Square X DORMONT SUPR — SAFE GAS APPLIANCE CONNECTOR rAx I O�� ��oc�2s 2$ MalnStreet Bldg. , i BER72070AOL.COM No. Easton, MA 02W NO. REVISIONS ilAIL 3 S PROVIDE LEAD FLASHING -CRIMP LEAD FLASHING WITH 12" FLANGE, MINIMUM _ NEATLY DOWN INTO FOP 2-12 LBS PER SQUARE ✓� _ I �— OF VENT PIPE ABOUT 1"' TYPICAL GAS-- -PIPE REDUCER FROM BRANCH FOOT. SET LEAD FLANGE FIRED ROOF-- PIPE SIZE; TO UNIT CONNECTION �-- - - JOIS VER VALVE BODIES WITH INSULATION, BUT NOT UNIONS PARTITION WALL-� STEPPED FLEXIBLE PVC OR NEOPRENE COUPLING CLAMPED IN BED OF MASTIC--- -� �� I -MINIMUM 12" ABOVE ROOF TOP AIR CON- SIZE, AT UNIT CONNECTION TO FLASHING AND PIPE WITH STAINLESS STEEL SCREW CLAMPS ( DITIONlNG UNIT PROVIDE MASTIC AT EDGES , TWO PLIES OF ROOFING THREADED PIPE TO __ -GROUND JOINT PIPE UNION � HU HIGH) PROVIDE GROUND-JOINT PIPE UNION OF ROOFING FELTS-- +�FELTS AND MASTIC PVC ADARTE_R ON / LEAD OR ___ ELBOWS TO OVER LEAD FLANGE CONDENSATE WASTE I rGAS SHUT-OFF COCK01 WC - ! � CONNEC,IONS . DO BRANCH PIPE - SEE COPPER COMPENSATE r NOT PROV01) RAP 0 PLAN FOR SIZE FLOOR FLASHING OR ROOFING OVER FOR PIPE ROOF INSULATION 1! 11 � w � l �, UNITS WITH INTEGRAL SPUN ALUMINUM METAL FLASHING EXPANSION +i ROOF DECK TRAP _. BRANCH OFF • + v I „ , , T� BASE IN BED I B. ROOFING � --� � � OP O, GAS ►�+ Wo MITER THE INSULATION AT APE JOINTS OF FI- a OF MASTIC. I CONTRACTOR �-- PIPE SUPPORT. _ PIPE MA! r�► �� COORDINATE TEES AND ELBOWS SO THAT BERGLASS INSUI ATION >>. WITH ROOFEF� I I REFER TU DErAIL `�,,_ �_____�._ _-L ANCHOR PIPE TO RdOF I THERE ARE NO GAPS AT JOINTS WHEN _ '-2" VENT "'> I .�_1 AS REQUIRED �-'�-- DOJE3L-F_ a POSSIBLE, THEN TAPE THEM. OTHERWIS VIDE A ONE FOOT -- - T ---- - BLOCI; 1 �_�--ROOF- INSULAR ION __-__._-____. —____ �. FILL THE GAPS WITH BLANKET FIBER- LENGTH OF NONCOMPRESS- - --` -- ---"- -�� ----- - - -- MINIMUM 12" BELOW Rre� , GLASS AND PROVIDE ONE-PIECE PRE- IBLE INSULATION AT f ROOF DECK ' �ry- EQUIPMENT CU plpE Sl1PPOR MOULDED PVC FITTING COVERS HANGERS FOR ALL PIPE SEE PLAN SL EE E ROOF _ —'-- PROVIDE PIPE INCREASER 2' AND LARGER FUR SIZE WHERE REQUIRED TO MAKE -- �~ HUBLESS PIPE: CONNECTORS SEE DETA! o PROVIDE 1 2" UNICELLULAR ELASTOMERI IF RE.QUIREd' NCHOR PIPE, TO ROOF DECK OR JOISTS / MINIMUM 3' VENT THRU ROfk �� ON CAST IRON PIPE 6" LONG DIRT LEG FULL •`�-t , INSULATION ON DOMESTIC HOT AND COL ER TO OTHER DETAILS REFER TO PLANS FOR PIPE SIZE(S) AND LOCATION($E SIZE OF BRANCH PIPE Q' WATER PIPES IN WALLS AND CHASES. FOR TREATMENT OF INSU- WELDED OR SCREWED FITTINGS AS SPECIFIED FOR pifiE SIZE. `+ MITER THE INSULATION AT TEES AND EL LATION AT PENETRATION LOCATE PENETRATION MINIMUM 18" FROM ADJACENT WALLS. REFER TO PLANS FOR VTR PIPE SIZES AND LOCALIONS, LOCATE VTR I;"y BOWS. SEAL ALL JOINTS WITH ADHE OF WALLS AND FIREWALLS TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE. PROVIDE 112" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET ON VENT PIPE INSIDE BUILDING FROM UNDERSIDE " OF ROOF, DOWN TO FIRST 90' FITTING, OR 5'0" VERTICAL LE^JGTH. I PROVIDE 1/2 FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPORPIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED. VERIFY FLASHING AND COUNTERFIASHING WITH ROOFING CONTRACTOR. BARRIER ON ALL COLD WATER AND CONDENSATE PIPE. PROVIDE t FIBER- GLASS INSULATION WITH ALL-SERVICE JACKET ON DOMESTIC HOT WATER PIPING, -+ - REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. ; INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS. HUB DRAIN ROOF PENETRATION VENT THRU ROOF (VTR) ROOFTOP UNIT CONNECTIONS MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT AND TAPE. 3 6 _ 8 ) 10 FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SCALE: NOT TO SCALE SCALE: NOT TO SCALE SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. -_ SCALE: NOT TO SCALE I SCALE. NOT TO SCALE THREE COMPARTMENT SINK WITH LEVER WASTES. 2" V - OVER HEAT TRRACINACIN PROVIDE 1" MERIC INSULATION G ON CONDENSATE PIPE INSULATION - BY GAS COMPANY VERIFY BY PLUMBING CONTRACTOR LINE -- IF/WHEN FREEZER BOX ONLY - �,� "'vs, 1 ( ) ELECTRIC HEATING CABLE IS BY OTHERS -STUB ELBOWS ABOVE F�GDR AT LacArloNs ����� " 4.,�, SILICONE SEAL ( ) SHOWN ON PLAN, 8' ON CARBONATOR/BEER END, 4s r'` ST'EVEN A ,, T SCALE: NOT TO SCALE PRESSURE TEST CO BUILDING WALL -- 180 DEGREE AROUND PIPE 14' ON DISPENSER END, TRIM ELBOWPf; ELBOW AIR INT KE GAS PIPE UP ON70 ROOF PENETRATION.. (- _ -`! 4 BACKKSPLASHND - - > GAS METER - CFH 1 SIZE AS SHOWN ON PLAN - I wf�- MECHANICAL CAPACITY SHOWN \ DX COIL ���a "�. ON PLAN a 6" ABOVE R! , USE BLACK STEEL PIPE 141, CLEANOUT ROOF 2" 2" CLEANOUTS PIPE INCREASER PROVIDE TRAP DEC IN ENDS _ STRAINE ji AT BOTTOM OF --PROVIDE CLEANOUT' � OF PIPI "+ DIRT LEG AT BOTTOM RISER ANDrDIS- IN TURNS AND END TOP BEAM ALL--THREAD ROD. j OF RISER - ANCHOR CHARGE !NiO f OF PIPE r C-CLAMP CLENGTH AS REQUI FLOW CONTROL FI ING RISER TO WALL RECEPTACLE i I IF STEEL � WITH AIR GAP OF MAKE CONNECTION BAR JOIST FOR PIPE SLOPE-'- ! - _ �+ FtUO Two PIPE TO COIL AS REQUIRLH� ROVIDE COPPER - RECESSED 3" ---------- PAVEMEN R OR NON-METALLIC FLOOR " T - 1_ DIAME.TERS--�� __NO INSULATION ON PIPE RISER —�/ / FL OO ADJUSTABLE COATING WHERE TYPICAL 3 - RECEPTACLE WALK-IN COOLER OR FREEZER CLEVIS HANGER FOR BAND HANGERHANGERS CONTACT LOCATE GREASE TRAP IN FLOOR NO PRESSURE REGULATOR SET AT 7" WC FOR PIPING PIPE OVER FOUR INCH _ FOUR INCH BARE COPPER PIP WHERE PEOPLE STAND BUT WHERE P UD J. CAN BE EASILY REMOVED FOR CLEANING. SHUT-OFF VALVE SEE FLOOR PLAN FOR RECEPTACLE LOCATION m OR LES INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX LENGTH AS REQUIRED ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. EIGHT INCH SCHEDULE 40 PVC ELECTRICAL CONDUIT AND Z N CONDITIONS OR MEET LOCAL CODE REQUIREMENTS. HUBLESS CONTRACTOR SHALL_ PAY ALL GAS COMPANY FEES FOR INSTALLATION WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER FITTINGS WITH SOLVENT-WELDED JOINTS. USE MINIMUM CAST IRON PIPE, FITTINGS AND CONNECTORS ALL AROUND SINK USE WELDED OR SCREWED PIPE AND FITTINGS PER PLUMBING SPECS. JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. QUANTITY OF FITTINGS REQUIRED. PROVIDE LONG SWEEP .- Z AND TRAP. CONNECT GREASE TRAP FROM CENTER COMPARTMENT: REFER TO LOCAL CODE FOR INDIRECT DRA N REQUIREMENTS. DO NOT HANG PIPE PROVIDE GALVANIZED STEEL SADDLE FOR ALL � ELBOWS AT BOTH ENDS, WITH MINIMUM 16 INCH RADIUS, LARGER THAN 3" FROM INSULATED PIPE LARGER THAN 3/4". VERIFY PROVIDE P-TRAP IF GREASE TRAP IS MORE THAN 4' FROM SINK. AVOID ELBOWS IN HORIZONTAL RUN IF AT ALL- POSSIBLE. 'Q z BOTTOM OF JOISTS. INSULATION THICKNESS WHEN SIZZING HANGERS. GT TO BE J.R. SMITH 8035 35 GPM ® 70 LBS OF GREASE OR EQUAL CL W Q PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN Q }- HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE CL m = PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER UTILITY SINK AND GREASE TRAP GAS SERVICE 9 CONDENSATE DRAIN 11 EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE 4 7 PVC r PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: — -- ---- - - - -- P VC SODA/ BEER CONDUIT N T S 3" ' 2--1/2"=10'- 2"=9'; 1-1/2"=8'; SCALE: NOT TO SCALE = SCALE: NOT TO SCALE SCALE: NOT TO SC:ALf:.� COPPER: 4"_-1,?"; 1 1 ; , 1-1/4 =7'; 1 =6'; 3/4"=6'• 1 2 =5'. CAST IRON: 1ONF NEAP ,}L JOINTS. _' c>a STEIL: 4 =14� 3,=12 , 2-1/2 =11 ; 2"=10'; 1 -1/2"=9 ; 1'-7 ; REMOTE SENSOR - 115- KITCHEN EQUIPMENT I CONNECTION SCHEDULE , � 4 , 3/4 =6'; 1/2 =5 . GATE VALVE MUST 140• t r LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS & TEES OF - --�i I ca PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF BE INSTALLEDREQUIRED. LOCATE HANGERS TO I-AKE LOAD OFF OF EQUIPMENT AHEAD OF VACUUM WASTE WATER i GAS CONN. I ° CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO RELIEF -� CW ►.D. FIXTURE/EQUIPMENT -- VENT --- -----( REMARKS CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS VACUUM RELIEF - THERMOMETER DW 1w CW 115'HW 140'HW ' SIZE LARD , REQUIRED BY LOCAL AUTHORITIES, CHAINS OR PERFORATED STRAP INSTALL IN — ----5 GAS IRON OR STEEL IS NOT ACCEPTABLE, REFER TO CODES FOR FURTHER 101 FORMATION. WATER LINE ONLY. + — 3 COMPARTMENT-POT SINK - 3" - I 1/2" 112' 2" AT OR ABOVE TOP POT FILLER T & S - - - 1/2" - - - » OF HEATER 102G _ _ _ 2 PIPE HANGERS U - -- -- - -- — --_-___ ----- SOUP WARMER - 1/2" - - - - - -- IW TO 3" FD _ SCALE: NOT TO SCALE iO3 - j 106 VEGETABLE SINK ! 2" 1 1/2" 1/2" - 2" 1 WATER HEATER TO BE A.O. SMITH '- - -- _-- --- ---- MODEL #PGC-75. 75 GALLON 110 SODA ICE DISPENSER - - 1/2" - - - - - FILTERED WATER 75 MBH, 75.9 GPH ----- --.__- _ .--------- - -- __- __ _.-- ------ RECOVERY AT 90' TEMPERATURE HAND1 1 HAND SINK 2" - 1/2 1/2" - 2" - - - RISE - --- _ -- ---- - -- ---- 112 COFFEE BREWER - - - 1/2" FILTERED WATER ¢ __ 114 ICE MACHINE - 3/4' 1/2' -- _ _ - 1/2" IW TO HUB DRAIN -! FILTERED WATER < PIZZA OVEN 1-1/2" 300K GAS HEATER COMBINED P & 11 - - _ - _ _ T REL.IEF VALVE r120 ---- -PASTA COOKER ---- ---- _ -- 1-1/4" 1/2„ 1/2"- - --' 3/4" _77_5K - _ -------- --- --- FOR TEMP. LJ_- RELIEF 121 FREEZER/COOLER -_-_ _ J---_- W GAS CONTROL _ _ & REGULATOR 125 SODA SYSTEM i - - 1/2" 1/2" I _ _ _ _ _ IW TO 3" FD Z PIPE TO DRAIN _ _ _ __ _ _ FILTERED WATER _ 132 QUICK DISCONNECT HOSE - I - _ - -_ - -` - DRIP LEG /2"-3/4" - SEE NOTE3 5 -- - - 139 _ - WATER FILTER _ i 1/2" _ - — ------ -- -.__ GAS FIRED STORAGE HEATER SCALE: NOT TO SCALE 141 FRYER - - _ - - - 1" 110K _ LL 143 �...__ GRIDDLE - ------ --�---�- -_-- 3/4" 7 --- - ---------- � - FIXTURE CONNECTION SCHEDULE 5K - SYMBOL FIXTURE cL ROUGH—IN REMARKS ---- --- — 504 MOP SINK i 2" -- 1/2" 1/2 — — -- 2" HW CW IN 510 WATER HEATER - - 1" 3/4" 1/2" - 3/4" 75K , FLOOR INSTALLATION-VERIFY •• AMERICAN STANDARD CADET 2168.100 i 2" IW TO MOP SINK ,. WC-1 WATERCLOSET (TANK) - 3/4" 4" 2 / 1.6 GPF TOILET W/ 5324.019 SEAT ADA --------------__.-- --____-------_-__-- TT �_- .--_+—__ t �,,,v�: r8 AMERICAN STANDARD #9141 O11 WHEELCHAIR LAVATORY W/ 4" CENTERS PROVIDE W/ #7490.1 72H WRIST - -- --- ---- _-----.__-..-----------___ - 3PuH. LAWL-1 LAVATORY (WALL HUNG) 1/2" 1/2" 1 -1 12" 1-1/2" BLADE HANDLES (PROVIDE HANDICAP COVERING _ UATE +o-I?9-1995 - ON TRAP PIECE AND STOPS) —� NOTES: 1. IW DENOTES INDIRECT WASTE TO FLOOR DRAIN. FD FLOOR DRAIN SEE PLANS FOR SIZE ZURN #ZN-415 FLOOR DRAIN, CAST IRON,BOTTOM 2. SEE EQUIPMENT CUT BOOK FOR ADDITIONAL REQUIREMENTS. SCALC 1 4 — _ --, - OUTLET, ADJUSTABLE COLLAR & TYPE B STRAINER 3. FOR PA STA COOKER, GRIDDLE AND FRYERS. `;AI~ E 1E PAGINO 98199 FCO FLOOR CLEANOUT SEE PLANS FOR SIZE ZURN #Z--1400 ADJUSTABLE. FLOOR CLEANOUT H. PA A CAST--IRON, ROUND SCORIATED TOP 98066 AMERICAN STANDARD CADET 2174.139 `MEET WC-2 WATERCLOSET (TANK) - 3/4" 4" 2" 1,6 GPF TOILET W/ 5324.019 SEAT Budding AMERICAN STANDARD #6501 .010 WASH13ROOK EC1ginef:I'ing TOP SPUD WITH SLOAN # 186-1 FLUSH VALVE j� - j UR-1 URINAL - 1/2' 2" 2" ResouiveS, Ific. TEL:(508) 230-0260 Shovel Shop Square 6 F A X: (508) 230-0265 28 Main Street, B Idgg. 3 A BER72070AOL.COM No. Easton, MA 02356 NO. REVISIONS DATE � y SECTION 15400 - PLUMBING factory-fabricated channels and assoclated accessories. Ensure adequate protection of equipment and undue strains and stresses, and provision shalt be D. Service+ Below ground sanitary waste, material during delivery, storage; installation and made for expansion, contraction and structural PART I GENERAL storm water and vent, 2,07 FLOOR DRAINS shutdown, and during delays pending final test of settlement. k Pipe Material, Service weight cast-Iron end systems and equipment because of seasonal 1,01 GENERAL soli pipe, aspholt or coal-tar A. Setting Grades- Before setting any drains, conditions B. lnterlor horizontal sanitary caste and storm pitch coated. Plumbing Contractor shalt obtain from the Gener at drolnage piping shot be installed in practical A. Conditions of the Contract and Division 1, General Pipe Joint- Caulked with lead and oakum or Contractor the exact information relative to finlsh C. Remove dirt and debris, and keep premises dean to alignment at uniform grade of at teast 1/8' per Requirements, apply to work of this Section. Where neoprene gaskets. grade at top of dralns satisfaction of Architect. Upon completion of foot but 1/4' per foot where possible. Paragraphs of this Section conflict with similar work, remove equipment and unused material. paragraphs of Division 1, requirements of this 2.03 VALVES B. Drain types and sizes shall be as Indicated on the C. Vents from fixtures or line of fixtures, when Section shall prevQk. Drawings or approved equal. as momIfactureci by Zurn D. Inspections by Architect- Periodic Inspectlons by connected to vent line serving other fixtures shalt Co„ J.R Smith. Architect or designated agent shall not be be extended at least 6' above flood level rim of B. As used in this Section, 'provide' means 'furnish construed as supervision of actual construction, highest of fixtures to prevent use of vent line as and install.' 2.08 TRAPS nor make efther responsible For providing soft .ante. ' A. Ball Valves place for performance of work of various trades or r� C Before submitting bid, visit and carefully examine A. Provide separate traps with Integral cteanouts on suppliers, or for visitors or occupants, or make D. Provide air gaps at (test twice diameter of waste 1Fr� - site to Identify existing conditions and fixtures and equipment that require connections to either responsible for omission of safety devices pipe between level• of each supply opening (except 1, Belt valves 2' and smaller on water services y y g y P protected with vacuum breakers) and flood r"difficulties that will affect work of this Section. sanitary system. except for fixtures with integral called for b codas, ordinances. or s ec!f{cations au*.lets shall be 2 piece all bronze with full port No extra payment will be allowed for additional traps. of mQnufocuturer of equipment supplied rim .of fixture receptacle w work caused by unfamillorlty with site conditions chrome-plated ball, psi seats, solder ends, a 4-bolt design, and 400 p psi cold working that are visible or readily construed by pressure. Appoto or Volts B. Traps exposed to view, including connecting drain. 3.02 MATERIALS AND WDRKMANSHIP F. Piping shall be run straight anal plumb and offsets >^, experienced observer: lines, shall be chrome-ptated, Traps shall be of shall be made at an angle of no less than 45 a s sizes shown on Drawings but shall not be less than A. VorMf shell be neat and rectltlnear, Piping shall degrees. Threaded Joints shall be as specified K D. Perform work and 2. Belt valves on Insulated piping shalt be 2-li 4' extended stems. ry provide material and equipment For 1-•1!c' curl concealed except in mechaWcai rooms and areas above i+l systems shown on Drawings and as specified Ir this without hung ceiling. Install material and w C iXi Section. Completely coordinate work of this 2U9 CLLAN13UTS equipment as recommended by manufacturer G. Carefully toy out work Ir advance so pipes shall Section with work of other Sections and provide B. Vacuum Breakers Instattotlon shalt operate safety anal without pass through opening and permit proper pitch to complete and futty-functional Installation. A. Provide cleanouts In soft, waste and storm drainage leakage. undue wear, r+oise, vibration, corrosion, pipeline. All trades shoU coordinate work with V Drawings and Specifications Form complementary 1. Atmospheric vacuum breakers shaft be al(-bronze, piping on straight runs at changes in directions or water hammer. Close pipe openings to prevent work of other trades to ovoid necessity of taking re uirementsi provide work for temperatures up to 210 degrees q p specified and not shown, and at foot of stacks and other points where obstruction and damage prior to completion: dawn work installed without prior checking. 4t he - and cork shown and not specified as though FQren required by inspecting authorities. Clearwuts expressly required by both. Although such work Is shall suit construction in which they are to be B. Except as specified otherwise, material and H. Soil pipelines shalt be thoroughly assembled with 2. Pressure vacuum breakers shall be aft-bronze, not specifically shown or specified, provide Installed equipment shall be Her. Provide supplies, joints of picked oil-free oakum packed tightly into For temperature up to 210 degrees Farenhel+., supplementary or, miscellaneous Items, p appliances and connections necessary for complete space between piles to a depth of appurtenances, devices, and materials Incidental to B. Cieanouts sha:i be same size as pipe 4' and and operational Installation Provide components Remaining !space shalt, be filled In by pouring with 2.04 INSULATION d �G or necessary for sound, secure and complete smaller. No reduction In cteanout sizes for pipe required or recommended by OSHA and NFPA, molten lead, caulked to ensure tight joints without G installation. Remove all debris caused by A. Insulation shalt be by Owens-Corning, Certain-Teed 4' and smaller Is permitted, straining bell. After- caulking, lead shad be S contractor's work, or Johns-Manville 3.03 INSTALLATION OF EPUIPMENT flush with ends of belt } C Traps not Integral with fixtures and in accessible E. Drawings are diagrammatic and indicate general locations shall have brass trap screw protected by A. Avoid interference with structure and with work of 3.13 TESTING AND ADJUSTING arrangement of systems and work Included In B. insulation shall be installed by Insulation firm water seal, and will be regarded as cteanout. other Sections, as r gt y g egf/red by codes and as Contract. It Is not intended to specify or to show regularly specializing In this work and employing necessary to meet manufacturer's installation and A. Test and adjust plumbing systems as specified and No cover particularly men py skilled therein, covering every offset, fitting or components however; D Bodies of cteanout ferrules In heft and spigot maintenance recemmendatbns. Installation shalt as required by Owner, Architect and authorities Contract Documents require components and materials applied by plumber's helpers will be acceptable piping shalt be standard pipe sizes conforming In permit cteQrance for access to equipment for that have Jurisdiction. Perform tests recommended whether or not indicated or specified as necessary thickness to that required for pipe and fittings repair. servicing and replacement by manufacturers of materials and equipment! this C. Insulation installation shall meet manufacuturer's to make plumbing Installation complete and rtguh^ement may be waived by Architect. recommendations. o suaon shalt be applied operntlonoperational, dti N Initi i. Ciennout ptug shall be cast brass with raised B. Provide suspended platforms, hany;Iers, supports, hlipoi ig has e passed test jurisdiction required by nut 3/4' high, Inserts, anchors, brackets, shelves, stands and 3.14 TESTING OF PIPING SYSTEMS hid �`;e�A F. Perform work strictly as required b uto y rules, J legs as necessary for Floor, wall- or ceiling-mounting JF q 4 ®• r ..�T- ..t_.� regulations, standards, codes, ordinances, and laws 2. Cltanouts In copper waste piping sheik be of equipment provided under tits Section A. General nSU on, ac s an adFnesves s omere J D IlQtlketd ihall be Ft - tordant =,ti *� of local, state, and Federal governments, and shall have ASTM E-84 fire hazard nments, and other soldered brass cleonout Fittings with extra as shown on Drawings Gnat +speclrled S Y EVEN authorities that have lawful Jurisdiction heavy brass screw plugs of same size as line. 1. Piping systems shall be subjected to testing �,`t, i► ratings of 25 flame spread, 50 smoke developed and Kr�RA+'1 rn g P C Provide cuts, weights and outer, pertinent data water or air a5 Hated and shalt hold tight at �is 50 fuel contributed. < c= MEC 11a;VICAL G. Materials and equipment shalt be listed by 3. Clennouts In threaded waste piping shad be required for proper coordinntfon of equipment the pressure head stated for the time interval <;c=• �` Underwriters Laboratories (UL), and approved by cast iron, dratr,nge T pattern, 90 degree support �rovfstons and installation. required without adding air or, water, While l I 69 ASME and AGA for Intended service. E. Insulation and jacketing shall be In accordance branch fitting with extra heavy brass screw any system +s being tested, required head or with Following- of same size as 1 x plugs pipe. 3.04 ACCESS AND ACCESS PANELS pressure shall ice maintained until ,joints are _ R Give notices. Fitt plans, obtain permits and Inspected. d*';• 5 y�l' �1� Fees and backchar s and obtain 1. Hot water shalt be Insulated with licenses, pay ge �� 4 Floor ctennouts In unFinlshed areas shall be A. Provide access to material or equipment which may necessary approvals From authorities that have heavy-density fiberglass with self-sealing lap cost Iron body and frame with cast Iron top, need Inspection, replacement, repair or service and 2. Tests shall be witnessed by Inspector having jurisdiction, and all service Jacket (ASJ). Fittings and J,R: Smith No. 4220 or approved equo: coordinate their delivery with the tnstalling jurisdiction and the Architect with 48~hour valves shall be Insulated with Insulating Trade notice given authorities. I. As work progresses and for duration of Contract, cement applied to thickness equal to that of E. Ctear+outs shalt open in direction of flow of maintain complete and separate set of prints of adjoining pipe Insulation and shall be covered drainage tine served or at right angles thereto. B. Access panels shalt have same fire rating 3. Equipment, materiat and tabor required for Contract Drawings at job site at all tines. Record with glass cloth jacket. Fittings may be classification as surface penetrated and shalt be testing of various systems or part thereof work c insutated with two layers of pre-cut F. r,ve completed and all changes From original blanket Insulation jacket with re-formed PVC p c14anout plugs clean and unimpeded. Pr trvtnt of least 12'x12'. shall be provided by Plumbing Contractor. fiberglass Contract Drawings clearly and accurately including a J P covering with cement, plaster or other permanent work Installed as a modification or addition to the covers Instead of tnsulating cement rinishing materials. 3.05 ANCHORS AND INSERTS B: Sanitary and Vent System original design and cloth Jacket. Insulation shalt be rated for maximum operating temperature of 450 2.11 UNIONS, FLANGES AND DIELECTRIC COUPLINGS A. Inserts shall be Iron or steel of type to receive 1. Water test shall be apptied to drainage 1.02 DESCRIPTI❑N OF WORK degrees Farenhelt Insulation thickness shod machine bolt head or nut after Installation. systems either In their entirety or in Q be V A, Unions, Provide union connections to fixtures and Inserts shall permit adjustment of bolt in one sections as required, after rough piping has A. The work of this section shalt Include and provide equipment such as water heaters. Union connections horizontal direction and shalt develop strength of been Installed, 2. Cold rater supply piping, valves and fittings all labor. tools and materials necessary., on domestic water piping shall be bronze with bolt when Installed In properly cured concrete. shall be Insulated as specified for hot water minimem cold working pressure of 200 psi. Urion 2. If applied to entire system, openings in Z N B. The following work is specifically In addition, continuous vapor barrierf alty Included without connections or, iron and steel small be ferrous with B. Provide ancriors as necessary for attachment of piping system shall be tightly closed, except llmiting the generalithy Implied by these plans and shalt be maintained. Use of staples or tacks working pressure matchinq service pressure equipment supports and hangers. the highest opening, and system filled with i M specifications, shalt not be permitted. Double wrapping of water to point of overflow. ri .... fittings insulated with blanket insulation Is Z not required. Insulation thickness shall be B Flanges, Provide flanges Ir accordance with ANSI 3.06 PENETRATIONS AND SLEEVES L Sanitary waste system, standards for construction and working pressure 3. If system Is tested In sections, each opening Q Z 2. Plumbing Fixtures Flange material shall be ferrous for ferrous piping A. General shaft be tightly closed except highest opening 3. Gas Piping systems and bronze for non-ferrous systems. In the section under test, and each section n and l id t h h F Pipe angers salt be outside Insulation shall 4. Domestic water piping 1 Provide pipe sleeves at penetrations of shalt be fitted with water but no section Q incorporate 12', 26 gauge protection shields. C. Dielectric Couptlrrgs� When domestic water piping Foundations, walls, slabs (except on-gr nde), shalt tee tested with Less than a 10' head of Q- (� M Insulation on piping that passes through walls or s stem pipe,comes In contact with ferrous partitions shall pass continuously through sleeves, y P partitions and floors water. 1.03 GUARANTEE fittings, valves or other components, connections except at Fire walls, smoke partitions, and floor sraU be made with dielectric flanges Contnc_t 2, Coordinate work carefully with Architectural 4 Water shalt be kept to system for at least 15 A. Guarantee Work of this Section in writing for one penetrations where space between sleeves and piping between ferrous stud bolts and non-ferrous bronze and structural work. Provide core drilling as minutes before Inspection stortsl the system year from date of Owners acceptance of Certificate shall be firestopped with approved packing. flanges shalt be electrkolly insulated with necessary to set sleeves In existing shall then be made tight at all points. of Substantial Completion. Repair or replace non--metallic washers construction. Do rot penetrate structural defective materials, equipment, workmanship and 2.06 HANGERS, ANCHORS, CLAMPS, AND INSERTS members without Architect's approval C. Points of drainage systems tested with air Instead installation that develop within this period, 2.12 JOINTING COMPOUNDS of water shall be tPSted by attaching an air � 0 A. Provide adjustable Bevis hangers for piping 2 and promptly and to Owner's satisfaction and correct larger, and cast brass spilt-ring hinged hangers 3. Sleeves for insulated pipe shall arc-MnmoaQte compressor testing apparatus to suitable opening damage caused in making necessary repairs and A. Provide pipe dope, Teflon tape, wax rings, neoprene -ontlnuous insulation without compression. and, after closing ail other inle-tis or outlets, C� replacements under guarantee within Contract Price. for smaller plying. Support piping from buildingstructure to maintain required grade and pitch of gaskets and other Jointing compounds ns required by forcing oJr into systems until a uniform gauge best standard practice and only on service as 4, Sleeves through floors shall be water-tight pressure of 5 psi or sufficient pressure to balance O pipe lines, prevent vibration; secure piping In 1.U4 SHOP DRAWINGS recommended by manufacturer and shall extend two' above floor surface n column of mercury 10' high Pressure shalt be place, and provide for expansion and contraction. held without Introduction or addltiona. air for a A. Submit appropriate shop drawings or descriptive Secure hangers to inserts where practical. Hanger B Pipe Sleeves period of of least 15 minutes. literature iv performance data, physical size, r0015 shall be machine threads. giving P 2.13 SLEEVES AND PENETRATIONS n. wiring dlagrams, configuration, capacity, material, through B. Trapeze hangers may be used where conditions 1. Annular space between pipe or pipe Irsulatior D, interior Water Piping System Upon completion of etc., for all Items under this Section Including A. Pipe Sleeves through floors and th structural and sleeve shots be at !east 1/4' water supply systems or section thereof, as the following- permit. Provide extended hangers for insulated p g g required, system shall be tested and roved tight piping with 12' long galvanized Insulation shields. and Fire-rated construction shalt be hot-dipped d Y P Hangers for copper shalt be copper galvanized Schedule 40 steel, Sleeves throw h 2 Sleeves through rated fare walls and smoke under a venter pressure of 1S(I pis:. Gauge shall be i. Plumbltg fixtures and trim. s PP Pr di pipe or bronze g g partitions shall matntoln Fire rat cF located on lowest new floor and pressure shall hold or shall he coated for dielectric {solatlon, partitions and nor-fire-rated construction shalt be u'►g p ' 2. Insulation, 26--gauge galvanized steel with lock tongitudlnnt construction penetrated. for a period of one hour without introducing � y 3, Floor drains and cleanouts seems Provide water roofln membrane locking additional water. Water used for testing shall be ,! C Hanger rods shall be connected to bean clamp, UL-approved p g 9 4, Valves and wall hydrants. devices at floors. Provide 150 Ib slip-on-on welding 3. Do not support plpMng risers on sleeves. from a potable source of supply, 5. Water Heater concrete inserts or Phillips or approved IP 9 � equal expansion shields. No ramset or shot shields flanges at exterior watt penetrotions. C. will be allowed Installation Testing, Listings and Approvals I. Defective Work, IF inspection or tests show - PART 2 PRODUCTS B Fire stopdefects, such defective work or mc.terlal shots be penetration seals In fire-rated D. Hanger spacing shall meet requirements of state and construction shall be ceramic fibre- mineral fibrei I. Installation shall meet material, replaced and inspection and tests shall be r 2.01 PLUMBING FIXTURES AND TRIM loco( plumbing codes. In no cases shall horizontal or silicone foam: Provide miner*( fibre board, manufacturer's recommendations exactly, repeated, Repairs to piping shad be made w,th new piping be supported at Intervals greater then 10'-0'. matting or putty for damming an min d forming. Finish particularly as regards preparation of material. No caulking of screwed joints or holes A Refer to Architectural and Plumbing Drawings For seals flush to wall surface and Fill gaps with surfaces, removal of Foreign materials safety shall be acceptable. quantities, types, locations and mounting heights E Friction clomps shall be Installed at base of silicone adhesive sealant caulking. Provide I' requirements, ventilation and other details of , of Fixtures provided under this Section thick ceramic fiber board on both sides of Installation. Dam openings as recommended 3.15 CLEANING plumbing risers. Friction clamps shall not be Remove flammable materials used for damming supported from or rest on floor sleeves. penetrations In 2- and 3-hour rated calls and m'+''inG B. Fixture trim, traps, faucets, escutcheons and waste Ftoors less than 8' thick: and forming stets In fir•e--rated construction. A. Clean systems thoroughly before testing Fixtures, pipes exposed to view In finished spaces shall be equipment, pipe, valves and fittings shall be free I polished chromium plating (CP) F Horizontal piping shall be suspended from building i LP.S. brass with p g + � Parkin for sleeves that do not require maintenance 2. Sleeve penetrntlon methods shalt be rater- and cif grease, metal cuttings, dirt and other foreign by mild steel rod connecting pipe hanger o g q q protective covers. Fixtures over nickel finish. of fire ratio shall be oakum, silicate foam, g9as-ti t and shalt meet requirements of ASTM material. Remove Inserts, beam clamps, angle brackets and :ag screws g F--119 tondard Methods of Fire Tests of Onctudin lavatories, water closets and urinals) / 1 as required by McIng Construction In accordance ceramic fibre or mherat fibre with approved g `f C. Enameled surfaces on cast iron fixtures shall be of with the following- sealant. Pack or foam to within one Inch of both Building Construction and Materials. shad be cleaned and ready for use. suitable thickness to provide the highest wall surfaces. Seat penetration packing with { 1 commercial grade. Rod Size Pipe Size approved caulking and paintable water-proofLd mastic 3. Fire-stop penetration seal methods and B. Repair stoppage, discoloration and damage to parts materials shall be FM-n r ,ed and UL--listed of building, finish and Furnt surface finish or silicone caulking. P 'Po' g, shhtgs due to failure D. Set fixtures with wall outlet flanges at proper as applicable to property clean piping system within. Contract distance from floors and walls with closet. setting 3/8, 1/2' to 2'1/2, 2-1/2' to 3--1/4' PART 3 EXECUTION Price. compound or gasket. 5/8, 4' to 5' 4 Inspect foamed sealants to ensure that 3.01 SPECIAL RESPONSIBILITIES Installation achieve manufacturer's optimum C. After completion of project, clean the exterior F. Catalog designations and manufacturer's names of 3/4' 6' cell structure and color ranges surface of equipment included In this section, vitreous china and enameled cast Iron fixtures are A. Coordination+ Cooperate and coordinate with work Including concrete residue G. Hangers on Insulated lines shall be sized to fit °� specified to establish standards of quality for the outside diameter of pipe Insulation Provide of other Sections In executing work of this 3.07 ESCUTCHEONS performance and materials. Equivalent fixtures by pipe coverts protection saddles at hangers on Section.Kohler or EIJer Ca may be submftted for approval g P n9 A. Install escutcheons around exposed pipe passing 3.16 DISINFECTION OF WATER SYSTEMS Insulated Ines r th h Finished Floor, wall, or ceRln 1 Perform work so that progress of entire �' g G. Vitreous china and enameled cast-Iron fixtures H. Piping at equipment and control valves shall be project Including work of other Sections Is Escutcheons shalt be heavy cast brass, chromium-plated. A. Water piping systems shall be thoroughly ,�' 9 shalt be white throughout unless specified not Interfered with or delayed. adjustable, shall. be of sufficient outside disinfected with a solution containing no less then supported equipment prevent strains of alves,tlo Piping +n v parts per miillon of available chiorine, otherwise. Closet seats shalt match closet Fixture connected equipment and Control valves. Piping at diameter to cover sleeve opening and shall fit 50 color. 2. Obtain detailed Installation Information from snugty around pipe. Chlorinating materials sholl be either liquidequipment shall supported to allow For removal manufacturers of a chtorine or soilum hy ochlorlte solution, shall be 2,02 PIPE MATERIALS of equipment, valves es, and accessories with a Section equipment provided under this 3.09 FLASHING AND COUNTER FLASHING Introduced Into the system and drawn to all points mltimum of dismantling and without requiring In the system. Disinfection solution shall be additional support after these items are removed. A. Floor drains shall be flashed watertight with 20 allowed to remain in stem for 24 hours, during s. Obtain final roughing dimensions or other g Y J A. Service, Above ground water piping 6' I Piping Installed under this Section shall be information, as needed For complete ounce sheet copper flashing which shall extend 8' this 'time, valves and faucets shalt be opened and and smaller (domestic, non-potable, protected). Installation of !terns furnished under other, beyond drain flashing flange- closed several times. After disinfection, solution PI Matial- 1 copper tubing, Independently supported from d structure and � er Type L opp not from pipinU, ductwork, or coannduiItt of other Sections or by Owner. shall be flushed from the system with clear rater conforming to Federal B. Provide counter- flashing for roof penetrations until residual chlorine content Is no greater than Specification WW-1-799 hard trades. Supplementary equirosteel, Including factory-fabricated required under this Section Including vents 0.2 arts per million � channels required to meet the 4. keep fully Informed as to shape, size, and q g P temper, requirements specified herein, shall be provided by position of openings required for material or Fitting Material, Wrought toper and bronze solder the Plumbing Contractor. equlpmet to be provided under this and other L. Flashing of vents and other penetrations of roof B Piping shalt be securely fastened, separatety hung joints. Sections. Give full Information so that required under this Sanction shalt be done under and shot( not support any other weight or piping. Pipe Joint, Lead free silver bright 100 solder J. Maximum spacing of hangers on extra heavy cast Iron openings required by work of this Section may other Sections Piping dropping in concrete block walls shall be soli pipe shalt be 5' and hangers shall be provided be coordinated with other work and other factory wrapped for corrosion protection. fDRAM P8 at aLI changes in direction. Hanger rods to openings and may be provided for in advance. 3.10 JOINTS AND CONNECTIONS B. Service+ Above ground sanitary waste and In case of failure to provide sufficient 3.17 CROSS CONNECTION PROTECTION APPR. vent. support ltping from the structure or supplementary P A. Joints and connections shalt be permanent and shalt LAW steel shalt not exceed 4' in total length. Information in proper time, provide cutting Pe Pipe Material- Service weight cast Iron no-hub and patching to full satisfaction of be gas- and water-tight. Jointing shall be types A. All potable water piping outlets and connections to conform to CS301, Plumbing Contractor shall provide P g specified for service Indicated. Alt transitions equipment or machinery shall be protected against DATE 10~09-as�8 ins Architect. Pe quipme Y P6 or type M between different piping materials shag( be made backflow by means of an air-gap or approved copper for drainage only, or B. Maintenance of equipment and systems, Maintain using approved adapters, backftow preventer. SCAL.F 1/4* s 11_0.. galvanized steel pipe standard equipment and systems until Final. Acceptance, weight for vent pipe only 3.11 INTERIOR WATER PIPING: B. Backflow preventer type, application and CAI) FiLE Fitting Material- Cast Iron, cast brass, Instoliatior shot( comply with the Commonwealth of H' PAPAGINO 9>�l199 stainless steel or wrought A. Water supply piping shalt be run as Indicated on Massachusetts. Department of Environmental copper drainage fittings to Drawings including mains, supplies to fixtures and Protection (DEP) Drinrcing Water Regu Cottons 310 CMR JOB NO. suit pipe material, indicated equipment Connie., tic,ns to fixtures shall 22.00. 98066 Pipe Joint- Gasket, screwed or soldered be from top of mains. except as noted, and piph)g SHEET with 95-5 lead free solder. shall be pitched at least I' in 40 feet so that it C. Submit plans to Water Department and obtain permit Building No-hub stainless steel can be dr•alned completely at tow points with Irafn for each reduced pressure or double check valve { KMR.esources, Building couplings on stacks 3' and valves which shalt be provided wherever necessary. backflow preventer Installation and sulamlt copies i larger shall be approved heavy Piping shall be pitched up toward fixtures for of permit to Architect for record Engineeringduty couplings equal to ANACO proper air relief j Husky SD400 or Clamp-All. END OF SECTION I 3.12 INTERIOR SANITARY WASTE AND VENT PTPING rlc. A. Provide waste, sdrainageshown and vent lines shown in TLL: P - 4f5lit 230-0260 Shovel sin Square building as shown on Drawings. Vents shall extend � ^'cf through roof and shot( Increase to at least 3', FAX: (508) 230 0265 28 Matti Street, Bidg�3A Piping shall be assembled and Installed without BER7207rAOL.COM No. Easton, MAOA)