HomeMy WebLinkAbout0058 HARBOR HILLS ROAD - Health 58 H.t-kRBOR 14ILL ROAD ,
Centerville
A = 247 — 069
S M E A D
No.H1630R
UPC 10259
smead.com • Made in USA
2 am
S Z
•
i
\ Commonwealth of Massachusetts
ha Title 5 Official Inspection Form
_ Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
• � tea
58 Harbor Hill Road-Assessor's Ma 2p 47 Parcel 69
Property Address Y9
Simone Gordon et als.
Owner Owner's Name
information is Centerville ✓ _ MA _ 02632 July 30,2016 h
required for every _ .mr
page. City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:When filling out forms A. General Information
on the computer,
use only The tab 1. Inspector:
key to move your
cursor-do not David D. Coughanowr, IRS
use the return Name of Inspector
key.
Eco-Tech Rapid Response
m Company Name
155 George Ryder Road South
Company Address
res� Chatham MA 02633
Cityrrown State Zip Code
508 364-0894 1328
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information repotted below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000).The system:
® Passes ❑ Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
r�
July 30, 2016
Inspector's Signature Date
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
"'"This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
+ Page t of 1)
.3113 ripe 5 Official Inspection Form:Subsurface sewago Disposal System•
I
Commonwealth of Massachusetts
Title 5 Official Inspection Form
1' I Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
58 Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Ovmers Name`
information Is
required for every Y Centerville MA 02632 Jul 30, 2016
required
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
Inspector's Notes==> The septic system described herein is deemed to pass this Real Estate
Transfer Inspection if it does not meet any of the failure criteria enumerated in Section D on pages 4-
5, or specified by local regulations.The scope of this inspection is limited to health and environmental
compliance and the septic system has been evaluated according to the conditions observed on the
day it was inspected. No estimate or guarantee of system longevity is made or implied by a passing
determination.
Do not park or drive vehicles over cesspools.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass"section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes","no"or"not determined"(Y, N, ND) for the following statements. If"not
determined,"please explain.
The septic tank is metal and over 20 years old'or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
"A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
i°:ns•3113 Tiro 5 Official InspoUion Form:subsurraco sawage Disposal System•Page 2 or 17
6e,
TOWN OF BAR�NS,TABLEUu���
LOCATI '(6,pr -�t( Ste- SEWAGE #
VILLAGE I� ASSESSOR'S MAP 6z LOT
INSTALLER'S NAME & PHONE NO.
SEPTIC TANK CAPACITY 006
LEACHING FACILITY:(type) yam- (size)
NO. OF BEDROOMS PRIVATE WELL PUBLIC WATER
BUILDER OR WNER2 ��
DATE PERMIT ISSUED:
DATE COMPLIANCE ISSUED: .
VARIANCE GRANTED: Yes No
7
�----
�� ��-o � �f�tt
.� -� � .
��
a'�°u �- �
� t1 �,��t
�' � �
i � � - . ?
i
� '�
����
����
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
58 Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name
information is Centerville _ _ _ _ _ MA 02632 Jul 30 2016
required for every y
page. Cilylrown State Zip Code Date of Inspection
B. Certification (cont.)
❑ Pump Chamber pumps/alarms not operational, System will pass with Board of Health approval if
pumps/alarms are repaired.
B) System Conditionally Passes (cont.):
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND(Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s).The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ❑ N ❑,ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
C) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
t5ins-3113 Title 5 Official Inspection Form:Subsurface sewage orsposai System-Page 3 of 17
i
Commonwealth of Massachusetts
- Title 5 Official inspection Form
is Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
t
58 Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name
information is required for every Centerville MA 02632 July 30, 2016
---
page. Cityfrown State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well".
Method used to determine distance:
This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
A co of the analysis must
i to or less than 5 ppm, provided that no other failure criteria are triggered. py Y
be attached to this form.
3. Other:
D) System Failure Criteria Applicable to All Systems:
You must indicate "Yes"or"No" to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
El ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
El ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ Liquid depth in cesspool is less than 6" below invert or available volume is less
than '/z day flow
15ins•3n9 Tillo 5 Official Inspection roan:suosunace Sewage Disposal system•Page 4 of 17
Commonwealth of Massachusetts
rr Title 5 Official Inspection Form
., m, ' J Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
58 Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name
information is Centerville MA_ 02632 Jul 30, 2016
required for every Y
page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ Z Any portion of the SAS,cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal conform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
❑ ® The system fails.I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails.The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
El El Area
system is located in a nitrogen sensitive area(Interim Wellhead Protection
Area—IWPA)or a mapped Zone II of a public water supply well
If you have answered "yes"to any question in Section E the system is considered a significant threat,
or answered"yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
151ns•3113 1'o:e 5 Official!nspcoian Form.Subsurface Sewage OiiDO531 Syslern•Gage 5 0!17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
58 Harbor Hill Road -Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner - - - -
Owner's Name
information is Centerville MA 02632 July 30, 2016
required for every —___._—..----• — --- _-- ---..
page. Citylrown State Zip Code Date of Inspection
C. Checklist
Check if the following have been done. You must indicate"yes" or"no"as to each of the following:
Yes No
® ❑ Pumping information was provided by the owner, occupant,or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
❑ ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
❑ ❑ Were as built plans of the system obtained and examined?(If they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components,excluding the SAS, located on site?
❑ ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS)on the site has
been determined based on:
❑ ® Existing information. For example, a plan at the Board of Health.
® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable)[310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
Number of bedrooms(design): n/a -- Number of bedrooms (actual): 2
DESIGN Flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): n/a
15Ins•3I1 3 Tille 5 official inspeclion Fair. Subsurface Sewage Disposal System•Page 6 of l7
i
Commonwealth of Massachusetts
; �. Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
u•/i 58 Harbor Hill Road-Assessor's Map 247 Pa_rcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name---- ---- - -_ -----
information is Centerville MA 02632 July 30, 2016
required for every _
page. Cityrrown State Zip Code Date of Inspection
D. System Information
Description:
No design plan, as built card, or permit application was found in the Health Dept files.
Number of current residents:
1
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system?(Include laundry system inspection ❑ Yes ® No
information in this report.)
Laundry system inspected? ❑ Yes ❑ No
Seasonaluse? ❑ Yes ® No
Water meter readings, if available(last 2 years usage(gpd)): 8 gpd
Detail:
2014: 3,000 gallons 2015: 3,000 gallons
Sump pump? ❑ Yes ® No
Last date of occupancy: current
Date
Commercial/industrial Flow Conditions:
Type of Establishment: —
Design flow(based on 310 CMR 15.203): Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft.,etc.):
Grease trap present? ❑ Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available: —.�.—_...'.
1 Sins•311.3 TiOa 5 offioal inspection Form:Subsudaco S^_eiage Disposal System•Page 7 of 17
Commonwealth of Massachusetts
1,�L� �. =r� Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
58 Harbor Hill Road_Assessor's Ma 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name _
information is Centerville MA 02632 _Jul 30, 2016
required for every .. . ._._ _. Y_
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use: Date
Other(describe below):
General Information
Pumping Records:
Source of information: Owner _
Wass stem pumped as art of the inspection? ❑ Yes ® No
Y P P P P
If yes, volume pumped:
gallons
How was quantity pumped determined?
Reason for pumping:
Type of System:
❑ Septic tank, distribution box, soil absorption system
❑ Single cesspool
® Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology.Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
t5ns•2r13 Tato S Official Inspezuon Form,subsurface Sewago Disposal System•Page 8 Of 17
I
i
Commonwealth of Massachusetts
Y �u« Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
58 Harbor Hill Road -Assessor's Map 247 Parcel_69
Property Address
Simone Gordon et als.
Owner Owner's Name
information is Centerville MA_ 02632 Jul 30, 2016
required for every Y
page. Cityfrovm State Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed (if known)and source of information:
Age unknown -No records at town hall.
Were sewage odors detected when arriving at the site? ❑ Yes ® No
Building Sewer(locate on site plan):
Depth below grade: 2feet
Material of construction:
®cast iron ❑40 PVC ❑other(explain):
Distance from private water supply well or suction line: feet
Comments(on condition of joints, venting, evidence of leakage, etc.):
Sewer line appears structurally sound with no evidence of leakage or backup into dwelling.
Septic Tank(locate on site plan):
Depth below grade: feet
Material of construction:
❑concrete ❑metal ❑fiberglass ❑ polyethylene ❑other(explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Dimensions:
Sludge depth: —
Title 5 oraaat inspoclion Fonn!Sucs.jrrace Sewage oisposai sysiern-Pape 9 01 17
Ens•3113
Commonwealth of Massachusetts
� Title 5 Official Inspection Form
4� — is Subsurface Sewage Disposal System Form- Not for Voluntary Assessments
� �=r
58 Harbor Hill Road_-Assessor's Map 247 Parcel 69
Property Address —
Simone Gordon et als.
Owner Owner's Name
information is Centerville MA 02632 J�30, 2016
required for every
page. CityrTown Stale Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank (cont.)
Distance from top of sludge to bottom of outlet tee or baffle ---i
Scum thickness —--
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
How were dimensions determined?
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Grease Trap (locate on site plan):
Depth below grade: feet- --
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle — —
Distance from bottom of scum to bottom of outlet tee or baffle --- - --- - _--
Date of last pumping: Date
i5ins•3113 TItio s olricial Inspection Form:Subsurface Sewage Disposal Systam•P298 10 of 17
Commonwealth of Massachusetts
. Title 5 Official Inspection Form
:? Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
fir. I
58 Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als. _
Owner Owner's Name
information is Centerville MA 02632 July 30, 2016
required for every
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑ polyethylene ❑other(explain):
Dimensions:
Capacity: gallons
Design Flow: gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments(condition of alarm and float switches, etc.):
Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
t5ins•:/+J Title 5 Official Inspection Form,Subsurface Sewage Disposal System•Page 11 of 17
Commonwealth of Massachusetts
R.r Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
58 Harbor Hill Road -Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name
information is Centerville MA 02632 July 30, 2016
required for every __.._ .. .... .. ..._._.....- .— — - -----
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Distribution Box (if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert ------ -—
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No`
Alarms in working order: ❑ Yes ❑ No'
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
If pumps or alarms are not in working order, system is a conditional pass.
Soil Absorption System (SAS) (locate on site plan, excavation not required).
If SAS not located, explain why:
ts.ns•'!t 3 Title 5 official Inspection Form.Subsurface sewage Disposal System•Page 12 of 17
Commonwealth of Massachusetts
�. __--_----_ Title 5 Official Inspection Form
—_' Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
58 Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address
Simone Gordon et als.
Owner Owner's Name _ --
information is Centerville MA 02632 Jul 30, 2016
required for every _ „ y
page. City(rown State Zip Code Date of Inspection
D. System Information (cont.)
Type:
❑ leaching pits number:
❑ leaching chambers number:
❑ leaching galleries number.
❑ leaching trenches number, length:
❑ leaching fields number, dimensions:
® overflow cesspool number: 1 overflow, 1
primary
❑ innovative/alternative system
Type/name of technology:
Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
No evidence of surface ponding, breakout, lush vegetation, or other evidence of hydraulic failure was
observed. Primary cesspool contained 1 foot of effluent.
Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration 2- 1 re imary`1 overflow
Depth —top of liquid to inlet invert 5 feet
Depth of solids layer 2 inches
Depth of scum layer trace
Dimensions of cesspool 6 ft x 6 ft approximately _
Materials of construction block ----
Indication of groundwater inflow ❑ Yes ® No
l5ins•3/13 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 17
\ Commonwealth of Massachusetts
`^ Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
58 Harbor Hill Road -Assessor's Ma- 247 Parcel 69
Property Address
Simone Gordon et als. _
Owner —.. - ---- ...—
Owner's Name
information is Centerville MA 02632 Jul 30, 2016
required for every _. _ _ Y
page. City/Town Slate Zip Code Date of Inspection
D. System Information (cont.)
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
Block cesspool systems can become unstable and collapse. Do not drive over or near cesspools.
Privy (locate on site plan):
Materials of construction:
Dimensions -
Depth of solids -
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5.ns•1/13 Title 5 Official Inspection Fam.Subsurface Sew-ago Disposal System•Pago 14 of 17
Commonwealth of Massachusetts
Al Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
56 Harbor Hill Road-Assessor's Map 247 Parcel 69 _
Property Address
Simone Gordon et als.
Owner Owner's Name
information is
Centerville MA 02632 Jul 30, 2016
required for every _ _y
page. Cilylrown Stale Zip Code Date of Inspection
D. System Information (cont.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below:
® hand-sketch in the area below
❑ drawing attached separately
—OF SEPTIC COMPONENTS
—DISTANCES IN DECIMAL FEET
A B
1 24 44
PRIMARY 1 2 '. OVERFLOW 2 35 30
CESSPOOL Y `' CESSPOOL
THIS SKETCH IS
A B BEST VIEWED IN
COLOR FORMAT
EXISTING
DWELLING NOT
SCALE
CC
3 �
O
d .e
HARBOR H§L LS ROAD 508 364-0894
t5ns•3I73
Title 5 official Inspection Form SueSurfaCe Sewage Disposal System•page 15 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
58"Harbor Hill Road-Assessor's Map 247 Parcel 69
Property Address --- --
Simone Gordon et als.
Owner Owners Name
information is
required for every
very Centerville MA 02632 July 30, 2016
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cost.)
Site Exam:
❑ Check Slope
❑ Surface water
❑ Check cellar
❑ Shallow wells
Estimated depth to high ground water: 20+
feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
❑ Observed site(abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health-explain:
❑ Checked with local excavators, installers-(attach documentation)
® Accessed USGS database-explain:
Barnstable GIS Department records
You must describe how you established the high ground water elevation:
Town of Barnstable GIS Department records indicate that the property is over 20 feet above
groundwater table.
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5ir,5.31t3 Title 5 Dffiaal Inspection Form,Subsurface Sewage Disposal System•Pago 16 at 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
� y 58 Harbor Hill Road-Assessor's Map 247 Parce__I 69
Property Address —
Simone Gordon et als.
Owner Owner's Name --— - - - -— - -- —
information is Centerville _
required for every MA 02632_ July 30, 2016
page. Cityfrown State Zip Code Date of Inspection
E. Report Completeness Checklist
® Inspection Summary: A, B, C, D, or E checked
® Inspection Summary D (System Failure Criteria Applicable to All Systems)completed
System Information— Estimated depth to high groundwater
® Sketch of Sewage Disposal System either drawn g p yon page 15 or attached in separate file
GEOHYDROLOGICAL PROFILE
- NOT TO SCALE
+
N
BOTTOM
OF
CESS
POOL
LEACHING IS
ABOVE HIGH
OAOUNOWATEA
5PEIR?
OUNDWATER ELEVATION
GIS MAPS
15,ns•&13 Title 5 olricini Inspection Form Subsurface Sew-Ago D.sposal System-Pape 17 o117