Loading...
HomeMy WebLinkAbout0225 MAIN STREET (CENT.) - Health 225 Main Street a Centerville A=209 - 043 i ,. Crlu1 �e 14 flu � UPC 12 L .2-153L TOWN OF BARNSTABLE LdCATION STo47- SEWAGE# Zvv&_I Z9 VILLAGE ASSESSOR'S MAP&PARCEL Q INSTALLERS NAME&PHONE NO. Co&a,,,aL Co^ST. t7vc g$39 58 q33+ SEPTIC TANK CAPACITY I S0© 6-4Lo- �/zv LEACHING FACILITY:(type)FPS. (size) ')c 9 NO. OF BEDROOMS 3 OWNER J >Ar,J EF7f-: PERMIT DATE: 3 f 3 I�/ZOOG COMPLIANCE DATE: '�- Separation Distance-Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility $.6Z Feet Private Water Supply Well and Leaching Facility(If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) 5,9. 9 Feet FURNISHED BY Jc �� �N�-� �, _1VU 273 0377 S 4 a o � o � DW E L1.1 N Cc a ol A S 1 17•JC lro 2 1 13•S 3 4 13•S �_ -- s 2-4.7 Sd.Z LQ e No.�� 1 Fee THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: es PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLEa MASSACHUSETTS - ZIpplitation for Zigpogar 6pgtm, tongtruction pernnit et Application for a Permit to Construct(`✓)Repair(�epgrade( )Abandon( ) O Complete System O Individual Components (� Location Address or Lot No. 22 S MA/" ��' "f Owner's Name,Address and Tel.No. p. C�u7�vit.e,� �,� 0�.�032 ��a.►a ni�ZF CIO Assessor's Map/Parcel Z� nl a�� ST 239^-ZS3 7112 Zo9 3 iec� Installer's Name,Address and Tel.No, Designer's Name,Address and Tel.No. c=Rowt�c . co�s Tve T�NN�� Z7� 0377 ZZto e,4 ldesr&7zAl 6j So P&'2'q%5 c4a,-iaW1j16-MvAy 3 VA CZ:53 Type of Building: Dwelling No.of Bedrooms 3 Lot Size sq.ft. Garbage Grinder Other Type of Building No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow 116 gallons per day. Calculated daily flow 3 3 O gallons. Plan Date ilo UVAJC Zoo, Number of sheets I Revision Date Title Vk. Size of Septic Tank I SODIrAL/AW 6AL PvMP CrfiaM&LType of S.A.S. P2ESSOAE DoSin is y T Description of Soil A 11 D G6 L.aAm K sg 2 I& Loa,- SA1p 4 72 - ' 72 /" ,o Nature of Repairs or Alterations(Answer when applicable) _/At_jA__/P0C11e PXe!;S-& 114— Fi&L Date last inspected: Q Agreement: The undersigned agrees to en a the c struction and maintenance of the afore described on-site sewage disposal syste in accordance with.the provisions of Title 5 of the Envtronmental Code an not to place the system to op Certifi Cate of Compliance has been iss d y is Boar f Health. Date 31IURZZna6 Application Approve Date 3 3/ Application Disapproved for the following reasons Permit No. Date Issued 3/ No. � I Fee .THE COMMONWEALTH OFYMASSACHUSETT$ ; �Entered in computer: 71— PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE., MASSACH'USETTS ZippYication for Miqual *pgtem Congtructton Vermtt �Q Application for a Permit to Construct( VRepair( epgrade( )Abandon( ) 0 Complete System ❑Individual Components C\ Location Address or Lot No. 2-2 S /4A 1 h) S'Mkl T Owner's Name,Address and Tel.No. C6747erv)LU.f✓ / 4 OL(o32 JOA.N r'j Assessor's Map/Parcel Z y 20 3' Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No. CRpw!?LL ca.✓51 N/C�oG4S 7�I 6 TVC NNr� 7c. ETA(r, zNG .$T ' Z 73 0377 � z ek. w�r� XJ So 2AY4 c,�a.�Bb iL�fl/6f7iaAy J 3 9 833¢ E. lti M IwA 6U3; Type of Building: Dwelling No.of Bedrooms 3 Lot Size sq.ft. Garbage Grinder( ) Other Type of Building No. of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow 1 1 b gallons per day. Calculated daily flow 3 30 gallons. Plan Date 16 ZWNE Zoo;- Number of sheets ( Revision Date Title 12rt �bsk-D SmMt u0G-2At7C Size of Septic Tank 1 SooGAL45D0 GAL X XP rAgM61gype of S.A.S. P2ESSvrLO 009;4- Sysibig Description of-Soil Fl II 0 64 s Lo MY'SA✓JL_) db"-66 WA__?y 5101/00 (68"-72-';� /ilk O 5�►D 72 Nature of Repairs or Alterations(Answer when applicable) C 7Av,)0:--/ M 4—D Date last inspected: Agreement: The undersigned agrees to ens a the con truction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Envtronmen a�o e and not to place the system m operat3ort¢undiLa Certifi- cate of Compliance has been issu-1 t .is Board Health. Sued Date 3/1'''1 Q 4 &OG Application Approve d`h I r ` ! Date Application Disapproved4or the following reasons Permit No. (9 Date Issued 3 -0`k THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE, MASSACHUSETTS Certificate of Comphance THIS IS TO CERTIFY, that the On-site Sewage Disposal System Constructed ( ) Repaired ( KUpgraded( ) ..,--Abandoned( )byat ca rf-,,a has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. ��0� �;3 9 dated 73 J 3//4- Installer ��'�� ..JF l\ Designer The issuance of this permits al of e/construed*aguargntee that the ystem will fu s des' ned. Date Inspecto — �- ------------------------- No. Fee THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION - BARNSTABLE., MASSACHUSETTS Mt5posW *p5tem Con$tructton Vermtt Permission is hereby granted to Construct( )Repair( Gade( )Abando ( ) System located at Y'Y Ya r- and as described in the above Application for Disposal System Construction Permit. The applicant recognizes his/her duty to comply with Title 5 and the following local provisions.or special conditions. Provided:Construction/must be completed within three years of the d`te of tKis-perm) Dater / �l J ApproveAy-. - Town of Barnstable Regulatory Services Thomas F. Geiler,Director * BARNSTABLE, MASS.: 10�' Public Health Division ArEo Thomas McKean,Director 200 Main Street,Hyannis,MA 02601 Office:. 508-862-4644 Fax: 508-790-6304 Installer & Designer Certification Form Date: 41�>2-0-04ewage Permit# Zoo6— I z9 Assessor's Map\Parcel �5 3 viCW0r_AS 17%PJNEX:_ Designer: ETC, En C-I M �e.r� ' L, (A( Installer: cayss`, .Luc. Address: Address: cam,—w / &Ap �. Dennis MA OU,60 On 31 rnQac;4 2ooG .v/c.,aAs 7A�e< was issued a permit to install a (date) (installer) septic system at z2�5- ,nanw sj (ev�c c��_based on a design drawn by Zr_ .-f>6-tl7 101elo_iC17` 11vc (address) dated 3 h IG Z�S' (designer) I certify that the septic system referenced above was installed substantially according to the design, which may include minor approved changes such as lateral relocation of the distribution box and/or septic tank. Stripout (if required).was inspected and the soils were found satisfactory. I certify that the septic system referenced above was installed with major changes (i.e. greater than 10' lateral relocation of the SAS or any vertical relocation of any component of the septic system) but in accordance with State & Local Regulations. Plan revision or certified as-built by designer to follow. Stripout (if required) was inspected and the soils were found satisfactory. 30 (InstallersSignature) ( Si ature) (Affix Designer s Stamp Here) PLEASE RETURN TO BARNSTABLE PUBLIC HEALTH DIVISION. CERTIFICATE OF COMPLIANCE WILL NOT BE ISSUED UNTIL BOTH THIS FORM AND AS- BUILT CARD ARE RECEIVED BY THE BARNSTABLE PUBLIC HEALTH DIVISION. THANK YOU. Q:\Septic\Designer Certification Form Rev 03-09-06.doc .t CAPE COD ENGINEERING, INC. Robert M. Perry, P.E. P.O.Box 1517 East Dennis,MA 02641 Tel 508-385-1445/Fax 508-385-1446 bobnerrvncapecod.net May 30, 2006 Town of Barnstable Regulatory Services Public Health Division 200 Main Street Hyannis, MA 02601 Re: 225 Main Street, Centerville, Septic System Construction Certification To The Public Health Division, I have been retained by the property owner/ applicant, Joan Neff to provide technical guidance in connection with the final permitting and construction of the referenced septic system project. Apparently the applicant no longer wishes to continue working with the firm responsible for the system design. I have indicated on the attached Certification Form that the engineer's certification is not the designer's certification. I have fully familiarized my self with the plan and design and provided several inspections on behalf of the owner during the construction work including soil removal, fill placement, general construction quality and a final lateral pressure test of the SAS. I hereby certify that the septic system was constructed in substantial compliance with the approved plan. Sincerely, Cape Cod Engineer , Inc. � rya R bert M. P , P.E. t '' �n E r y LJ N 44 -J► �b FL Town of Barnstable x Board of Health 200 Main Street Hyannis MA 02601 Office: 508-862-4644 Wayne Miller,M.D. FAX: 508-790-6304 Sumner Kaufman,MSPH Paul J.Canniff,D.M.D. January 25, 2006 Mr. John L. Churchill, Jr., P.E. JC Engineering, Inc. 2854 Cranberry Highway East Wareham, MA 02538 % , r a za cam•- i x . Rx 51WO-10 Dear Mr. Churchill, You are granted multiple conditional variances on behalf of your client, Joan Ann Crivelli-Neff, to construct a replacement sewage disposal system at 225 Main Street, Centerville, Massachusetts. The variances granted are as follows: Section 360-1: The leaching facility will be located 40.1. feet away from the bordering vegetated wetland , in lieu of the minimum 100 feet setback separation distance required. Section 360-1: The septic tank/pump chamber will be located 40.8 feet away from the bordering vegetated wetland , in lieu of the 100 feet setback separation distance required. 310 CMR 15.211: The soil absorption system will be located five (5) feet away from the front property line in lieu of the minimum ten (10)feet separation distance required. 310 CMR 15.211: The soil absorption system will be located five and nine- tenths (5.9) feet away from the foundation wall in lieu of the minimum twenty (20) feet separation distance required. 310 CMR 15.211: The septic tank/pump chamber will be located eight and two- tenths (8.2) feet away from the garage slab foundation in lieu of the minimum ten (10) feet separation distance required. Q:WP/ChurchillNeff 2006 c f " 310 CMR 15.211: The leaching facility will be located 40.1 feet away from the bordering vegetated wetland , in lieu of the 50 feet minimum setback separation distance required as required by the State Environmental Code, Title 5. - 310 CMR 15.211: The leaching facility will be located eight and one- tenth (8.1) feet away from a subsurface drain in lieu of the minimum ten (10) feet separation distance required. 310 CMR 15.240(4): There will be a 25% reduction in the leaching facility area as allowed by 310 CMR 15.404 (2) (d). These variances are granted with the following conditions: (1) No more than three (3) bedrooms maximum are authorized at this property. Dens, study rooms, offices, finished attics, sleeping lofts, and similar-type rooms are considered "bedrooms" according to the MA Department of Environmental Protection. (2) The applicant shall record a properly worded deed restriction, signed by the owner of the property, at the Barnstable County Registry of Deeds restricting the property to three (3) bedrooms maximum. A copy of the recorded deed restriction shall be submitted to the Health Agent prior to obtaining a disposal works construction permit. (3) Any future expansions or additions to the home and/or any changes to the footprint are not authorized. Future proposals to construct any additions and/or changes to the footprint shall be submitted by the applicant to the Board of Health to be reviewed at a public meeting, prior to approval. (4) The septic system shall be installed in substantial compliance with the engineered plans dated June 16, 2005. (5) The professional engineer shall supervise the construction of the onsite sewage disposal system and shall certify in writing to the Board of Health that the system was installed in substantial compliance with the engineered plans dated June 16, 2005. These variances are granted because the physical constraints at the site severely restrict the location of the soil absorption system due to its close proximity to wetlands bordering three sides of this lot. The subject wetlands are not immediately adjacent to any shellfish resource areas or public bathing beaches. The engineer designed a soil absorption system, which will be pressure distributed, to be located at the center- front area of the property as far away as possible from the wetlands on this particular lot. Thus, the proposed Q:WP/ChurchillNeff 2006 r plan appears to meet the maximum feasible compliance standards contained within the State Environmental Code, Title 5. Sincerely yours, WaynW Miller, M.D. Chairman Q:WP/ChurchillNeff 2006 5 j ©b�dI !)F t? r DATE: t FEE: t�ABE + 7 ��p � . BY 63q. b Town of Barn-stable SCHED. DATE: Board of Health�vlolot� 200 Main Street,Hyannis MA 02601 Office: 508-862-4644 Susan G.Rask,R.S. FAX: 508-790-6304 Sumner Kaufman,M.S.P.H. Wayne A.Miller,M.D. VARIANCE REQUEST FORM LOCATION J Property Address: z5 }"laid SA(ee, i GEr1kayi('e � M Assessor's Map and Parcel Number: 209 / 0 y 3 Size of Lot: / 6 0 5' Wetlands Within 300 Ft. Yes X Business Name: No Subdivision Name: APPLICANT'S NAME: 30�nn Chu(bnt 1( .�J<, P. �, Phone 5 0 6 ,Z 7 3 -o 3 7 7 Did the owner of the property authorize you to represent him or her? Yes X No PROPERTY OWNER'S NAME CONTACT PERSON Name: SGctan AAA Cc(U6kt N•e- E Name: `56-wl LhmrcW10 5C c o,30n ee;i n3 Address: 3300 C'_ 'DcWe_ Uci,{ -iU3 Address: ,5y C(-anbe((y t{ic�nwny Nod\es, l 3ylo 3 L, Wafemorn l A 025 3 8 Phone: 23 g - ro 5 9 Dq to Phone: 50 b,Z y 3_037 9 VARIANCE FROM REGULATION(List Reg.) REASON FOR VARIANCE(May attach if more space needed) SCL' A, TACO C7 SNCE T NATURE OF WORK House Addition 0 ????? House Renovation 0 Repair of-Fe4ed Septic System cr►*'cH Does NiT Z7 ONSIASCE Checklist (to be completed by office staff-person receiving variance request application) Mcy• Please submit copies in 4 separate completed sets. Four(4)copies of the completed variance request form _ Four(4)copies of engineered plan submitted(e.g.septic system plans) _ Four(4)copies of labeled dimensional floor plans submitted(e.g.house plans or restaurant kitchen plans) _ Signed letter stating that the property owner authorized you to represent him/her for this request _ Applicant understands that the abutters must be notified by certified mail at least ten days prior to meeting date at applicant's expense (for Title V and/or local sewage regulation variances only) Full menu submitted(for grease trap variance requests only) C:\Documents and Settings\decollik\Local Settings\Temporary Internet Fi1es\0LK3\VARIREQ.D0C OKI i JAN UARY 17,2W DEAR BOARD MEMBERS; AS YOU REQUESTED I BROUGHT MY SEPTIC PLANS TO VARIOUS CONTRACTORS. MACOMBER WAS UNABLE TO HANDLE THE ALTERNATIVE SYSTEM .AFTER SUBMITTING PLANS TO BOUSEHOUSE AND NORTHSIDE,I WAS TOLD THAT THEY JUST DIDN'T HAVE TIME FOR IT, AS THEY WERE TOO BUSY. BORTOLOTTI AND PASTORE DID GIVE ME PROPOSALS ,THAT ARE AS FOLLOWS: j I'I;AI 41-I'ANI AND RUMP CI NM EI2 PLAN 42 ALTERNATIVE w1...�.._...a. 1 (!ORTOLOTTI 19,900 29,500 1 sT YEAR MAINTENANCE - 1,110 (TOTAL-19,900� TOTAL-30,610 PASTORE 21,500 31,500 1 sT YEAR MAINTENANCE 1,110 TOTAL-21,500) TOTAL-32,610 I ALSO GOT QUOTES ON DRIVEWAY AND STAIRWAY REPLACEMENT. NARDONE CONSTRUCTION (DRIVEWAY) - 1,400)' VILLAGE MASONRY(STAIRWAY)- 1 XO) THE ENGINEERS,'JC ENGINEERING-WAREHAM HAVE BEEN PAID(-S_,_052.34 BY THE SEPTIC LOAN THRU KENDALL AYRES ( COUNTY) .a I GOT THE COST OF SERVICE AND TESTING REQUIRED FOR THE LIFE OF THE ALTERNATIVE SYSTEM FROM JR SALES IN RAYNHAM. THAT ISf570 A YEAR. ASSUMING I WOULD USE BORTOLOTTI SERVICES;THE LOWEST QUOTE; THE TOTALS WOULD BE AS FOLLOWS: PLAN41 -29,152 LP'� #2-39,862 THESE FIGURES DO NOT INCLUDE ADDITIONAL COSTS-REMOVAL TO TRY TO SAVE SHRUBS ,REMOVAL AND REPLACEMENT OF FENCING AND RELOCATION OF BOTH GAS AND WATER LINES. THE ENGINEER STILL NEEDS TO COMPLETE AN AS BUILT PLAN AND I AM SURE OTHER CHARGES WILL ARISE. I HAVE ATTACHED COPIES OF THE ABOVE PROPOSALS AND HOPE THAT THIS . TREMENDOUS COST WILL BE TAKEN INTO CONSIDERATION,WHEN DECIDING MAXIMUM FEASIBLE COMPLIANCE. I AGAIN AM REQUESTING A HARDSHIP FINDING BASED ON FINANCIAL CAPABILITIES. THE ENGINEERS AND CONTRACTORS BELIEVE PLAN##I TO BE AN EFFECTIVE SYSTEM AND CERTAINLY MORE EFFICIENT THAN THE EXISTING CESSPOOL. I AM NOT IN A NITROGEN SENSITIVE AREA;LIKE THE PENDING CASES OF THE CONDOMR41UM COMPLEXES HERE. THERE ARE NO LAKES OR PONDS ON THE PROPERTY AND THERE WOULD BE NO INCREASE IN FLOW. I HAVE BEEN INVOLVED IN THIS PROJECT FOR OVER A YEAR AND A HALF NOW,AND HOPE THAT WITH YOUR KELP TONIGHT,I CAN PROCEED TO THE NEXT STEP OF PLANNING AN INSTALLATION OF MY SEPTIC. I KNOW THERE HAS BEEN A LOT OF FRUSTRATION INVOLVER AND I WANT TO THANK YOU FOR YOUR TIME AND EFFORTS. SINCERELY, r JOAN A.NEFF 225 MAIN STREET CENTERVILLE,MA. x Is M � O Ch N O AUG-02-2005 12 :27 PM JCENGINEERING 508 273 0367 P. 01 JC ENGINEERING, Inc. Civil & Environmental Engineering 2854 Cranberry Highway East Wareham, Massachusetts 02538 � Ph. 508-273-0377—Fax 508-273-0367 7ijul- July 27, 2005 y, - Mr. Wayne Miller, M.D. Board of Health Chairman 200 Main Street Hyannis, MA 02601 RE: Request for Hearing Continuance for 225 Main Street, Centerville, Massachusetts Dear Mr. Miller and Board of Health Members: We respectfully request that the public hearing be opened and any attending abutters be notified that a continuance of the hearing for the Board of Health Variance Application for 225 Main Street will be on September 6, 2005. Thanking you in advance for your cooperation, I remain, Respectfully yours, �r� 1 /JohnL. Churchil r., P.E., C.S.E. dent, for the petitioner Copy: Joan Ann Crivelli XV1782 f Crocker, Sharon To: McKean, Thomas Subject: BOH -225 Main St, Centerville John Churchill,JC Engineering, is representing 225 Main St, Centerville. 508-273-0377 They want to postpone their presentation to Board until 9/6. They have faxed a formal request(in your mailbox) Please check the wording on it. I expressed it is their responsibility to inform abutters for next meeting. Please call them IF they are not all set to go to Sep 6 BOH. Thank you. .r. 1 a �5 ,�`�'�' �� `� .�j �� (�" �, C���� � � t s ,��, S� A.M. FOR DATE TIME P.M. M all A ;PHDNEP '; OF PHON YQL1R CALL', AREA CODE NUMBER E NSION ' AL£ASE CALL'. ME WAGE /J� U1lai L CALL, p(, •AGAIN Qo l SIGNED Versal-48003 NOTES ,L AUg-26-05 09:06pm From- RDEX KINKOS 2304349179 T-471 P.002/002 F-633 e August 29,2005 Dear Mr.McKean, 1 am in need of guidance from you as to the procedures required for a reconsideration of the septic upgrade presented to the Board on 7-12-05.It was not granted due to a 40.1 setback from the wetland. I am a widow on a fixed income of$14,000 and have been worldng with Barnstable County on their septic loan program.I started this project a year ago and the cost of Engineering alone is at$6500 to date,without a final resolution.I have decided that I must now represent myself in this matter;to stop any further costs and protect my interests. To install a septic system,I will have to replace my driveway, front stairway,mature shrubbery on two sides of the house,move my water line and take down my magnificent 50 year old tree in ray frontyard.Then there is the cost of the new system,a great amount of fill,the plumber and electrician and who knows what else?The total with an alternative system comes close to$40,000.I feel that this hardship was not caused by my C actions and that the original proposal is a great improvement over the 50 year old cesspool that now exists. The property is very confining and I have no where else to go.I have tried to meet the maximum feasible compliance to the best of my ability,and am able to pursue this project only to a point;as I have to consider not only the total cost,but firiwe loan payments,maintenance and repairs.All of this is beyond my means. On 8-24-05,I spoke to Brian Dudley(508-946-2753)at DEP in Lakeville.I explained that we bad made a 25%reduction in the leaching facility and were still 4011 feet from the wetland.He said that DEP was willing to look at this original plan submitted on 7-12- 05.He said they would consider 15.405-economic feasibility, 15.405(f)and(g),also(I) #5.He told me to go to the board and request their.stamp of approval and have it sent to DEP for review,as they would need to review it anyways.He said if they were:unable to approve they would try to help me work out something other than an alternative system. I am next scheduled for 9-06-05 with the revised plan of an alternative system submitted by JC engineering. I do not want to pursue that plan at this time. I appreciate your efforts in helping me through this difficult situation and await your suggestions.Please call me on my cell phone. 239-253-7112 Respectf dly, Joan A.Neff 225 Main Street Centervikle,Ma 02632 t , �1 y i g [� 1<.I d>�� 1 a��I {nth. {t.- August 29, 2005 Dear Mr. McKean, £ ` "�' ' 2 9 I am in need of guidance from you as to the.procedures-r-equir-ed for a reconsideration of the septic upgrade presented to the Board on 7-12 15 1Itl as not granted due to a 40.1 setback from the wetland. I am a widow on a fixed income of$14,000 and have been working with Barnstable County on their septic loan program. I started this project a year ago and the cost of Engineering alone is at $6500 to date, without a final resolution.I have decided that I must now represent myself in this matter; to stop any further costs and protect my interests. To install a septic system, I will have to replace my driveway, front stairway,mature shrubbery on two sides of the house, move my water line and take down my magnificent 50 year old tree in my backyard. Then there is the cost of the new system, a great amount of fill, the plumber and electrician and who knows what else? The total with an alternative system comes close to $40,000. I feel that this hardship was not caused by my actions and that the original proposal is a great improvement over the 50 year old cesspool that now exists. The property is very confining and I have no where else to go. I have tried to meet the maximum feasible compliance to the best of my ability , and am able to pursue this project only to a point; as I have to consider not only the total cost, but future loan payments, maintenance and repairs. All of this is beyond my means. On 8-24-05, I spoke to Brian Dudley(508-946-2753) at DEP in Lakeville. I explained that w had made a 25% reduction in the leaching facility and were still 40'1 feet from the wetland. He said that DEP was willing to look at this original plan submitted on 7-12-05. He said they would consider 15.405- economic feasibility, 15.405 (f) and (g), also (I) #5. He told me to go to the board and request their stamp of approval and have it sent to DEP for review: as they would need to review it anyways. He said if they were unable to approve they would try to help me work out something other than an alternative system. I am next scheduled for 9-06-05 with the revised plan of an alternative system submitted by JC engineering. I do not want to pursue that plan at this time. I appreciate your efforts in helping me through this difficult situation and await your suggestions. Please call me on my cell phone. 239-253-7112 Respectfully, Joan A. Neff 225 Main Street Centerville,Ma 02632 1 Crocker, Sharon To: McKean, Thomas Subject: BOH 9/6-225 MAIN ST, CENT. Please call Mrs. Neff, 225 Main St, Centerville, cell 239-253-7112, She is, again, on BOH agenda-Sep. She is finding engineers fees too costly and has spoken to DEP. DEP said they were willing to consider her situation. She would like the original plan submitted on Jul 12th mtg attached to this meeting and at meeting she'll present discussion with DEP. (currently engineers had submitted a revised plan- please take this out). 1 Michael Pimentel, E.I.T., C.S.E. Michael Pimentel, E.I.T., C.S.E. Project Manager Project Manager JC ENGINEERING, INC. JC ENGINEERING,INC. Civil&Environmental Engineering Civil&Environmental Engineering 2854 Cranberry Highway Phone 508-273-0377 2854 Cranberry Highway Phone 508-273-0377 E.Wareham,MA 02571 Fax 508-273-0367 E.Wareham,MA 02571 Fax 508-273-0367 I mpimentel@jcengineeringinc.com mpimentel@jcengineeringinc.com i as JC ENGINEERING, Inc. � Civil & Environmental men tal Engineering n g 2854 Cranberry Highway East Wareham, Massachusetts 02538 Ph. 508-273-0377—Fax 508-273-0367 July 27, 2005 Mr. Wayne Miller, M.D. Board of Health Chairman 200 Main Street Hyannis, MA 02601 RE: Request for Hearing Continuance for 225 Main Street, Centerville, Massachusetts Dear lair. Miller and Board of Health Members: We respectfully request that the public hearing be opened and any attending abutters be notified that a continuance of the hearing for the Board of Health Variance Application for 225 Main Street will be on September 6, 2005. Thanking you in advance for your cooperation, I remain, Respectfully yours, C /JohnL. Churchill, r., P.E., C.S.E. <dent, for the petitioner N "' >. o Z: U Copy: Joan Ann Crivelli ry �- Cn r r rn JCE#782 Town of Barnstable August 31,2005 Board of Health 200 Main Street Hyannis,Ma. 02601 Dear Board Members: I am scheduled to appear on Sept. 6, 2005 for a hearing before the board. I am requesting a postponement until October 11,2005. Thank you. Joan A.Neff 225 Main Street Centerville, Ma. 02632 Q � 2-1 i e .-r f L3 Q9 tt1 .J •.a, VARIANCE FROM REGULATION AND REASEON FOR VARIANCE In accordance with 310 CMR 15.401-15.405, the following local upgrade approvals are requested: (1.) A 5.0' variance (10'—5') for the setback from the front property line to the proposed leaching facility. Reason: Size of leaching facility too large and also to maintain 5 foot over- dig within property limits. (2.) A 14.1' variance (20' - 5.9') for the setback from the foundation to the proposed leaching facility. Reason: Size of leaching facility too large and also to maintain 5 foot over- dig within property limits. (3.) A 25% reduction in the required subsurface disposal area design requirements. Reason: Size of leaching facility too large and also to achieve a greater separation distance between leaching facility and the BVW. (4.) A 1.8' variance (10' - 8.2 ') for the setback from the garage slab foundation to the proposed septic tank / pump chamber. Reason: No other location to site the tank without moving it closer to the BVW. (5.) A 9.9' variance (50' -40.1') for the setback from the BVW to the proposed leaching facility. Reason: Size of leaching facility too large and also to maintain 5 foot over- dig within property limits. (6.) A 1.9' variance (10' - 8.1') for the setback from the subsurface drain to the proposed leaching facility. Reason: Size of leaching facility too large and there is no other location to site the leaching facility without moving it closer to the BVW. I Page 2 June 16, 2005 The following local variances are requested from the Barnstable Code—Board of Health Regulations Article I,Section 360-1: (1.) A 59.9' variance (100'—40.1') for the setback from the BVW to the proposed leaching facility. Reason: Size of leaching facility too large and also to maintain 5 foot over- dig within property limits. (2.) A 59.2' variance (100' —40.8') for the setback from the BVW to the proposed septic tank / pump chamber. Reason: No other location to site the tank without moving it closer to the BVW. -; , 44 1ST FLOOR 33'-7" 1-----19'-3" 11'-6" DINING LIVING t-2'-5" INr2-', CL: CL. KITCHEN - BEDROOM #1 BATH ----13'-0"---) 5'-0" -- ---12'-1"-- 2ND FLOOR ---11'-7"—'� ---i 4'-0" ----4'-0"---I 4'-0" CL. 15'-8" BEDROOM #2 BEDROOM #3 CL. BATH CL. XN *NOTE: UNFINISHED BASEMENT IS NOT SHOWN. Floor Plan of 225 Main St. JC Engineering, Inc. Centerville, MA 2854 Cranberry Highway January 11, 2005 SCALE: 1"=10' E. Wareham, MA02538 Prepared for Joan Neff (508)273-0377 74glo5- h J ENGINEERING, nc. Civil & Environmental Engineering I C) Ph 0,1. 8<:liN$1Y285�Cranberry Highway � East Wareham,Massachusetts 02538 n PA0 2A-0377—Fax 508-273=0367 i� MFF'i'ING NOTICE ) DIVISIONDear Abutter: �'• 0- You are hereby notified that there will be a public meeting on Tuesday, July 12, 2005 at 7:00 PM / '- in the Selectman's Conference Room in the Barnstable Town Hall, which is located at 367 Main UW Street, Hyannis, MA 02601. This meeting is to present variance requests associated with a Septic System Upgrade at 225 Main Street, Centerville, Massachusetts. This project is necessary for the upgrade of an existing failed septic system. Due to site constraints, we are requesting the following of and Local Upgrade- Approvals pursuant to 310 CMR 15.401 - 15.405: (L) A 5.0` variance (10'—5') for the setback from the front property line to the proposed leaching facility. (2.) A 14.1' variance (20' -5.9') for the setback from the foundation to the proposed leaching facility. (3.) A 25% reduction in the required subsurface disposal area design requirements. (4.) A 1.8' variance (10' - 8.2 ') for the setback from the garage slab foundation to the proposed septic tank / pump chamber. (5.) A 9.9' variance (50' -40.1') for the setback from the BVW to the proposed leaching facility. (6.) A 1.9' variance (10' - 8.1') for the setback from the subsurface drain to the proposed leaching facility. (7.) A 59.9' variance (100'—40.1') for the setback from the BVW to the proposed leaching facility. (8.) A 59.2' variance (100' —40.8') for the setback from the BVW to the proposed septic tank / pump chamber. The application and plans are available for review at the Barnstable Health Department, 200 Main Street, Hyannis, MA Monday through Friday (excluding holidays) from 8:30 a.m. to 4:30 p.m. Si erely, John L. Church' , Jr., P.E. President JLC/mcp JCE#782 i Joan Ann Crivelli-Neff 225 Main Street ; Centerville, MA 02632 December 28, 2004 Board of Health Town of Barnstable 200 Main Street Hyannis, MA 02601 RE: Declaration of Authorization Dear Members of the Board: Let it be known that I, Joan Ann Crivelli-Neff, do hereby authorize JC Engineering, Inc. of East Wareham, MA 02538 to represent my interests regarding the upgrade of the sewage disposal system located at 225 Main Street, Centerville, MA in meetings both public and private. SinceDCrivelli-Neff Joan L . W:UOBS-ACTIVE\782-225 Main Street(Neff)\Administradve\05 Authorization Letter.doc LETTER OF T2ANSMY �T L r., JC Engineering Inc. P�'�2_ 16 Civil&Environmental Services µ~ 2854 Cranberry Highway Telephone. 508-273 03 VZ E.Wareham,MA 02538 Facsimile: 508-273-0367 TO: Town of Barnstable DATE: 06/16/05 JOB NO. 782 Board of Health RE: BOH Variance Package 200 Main Street 225 Main Street Hyannis,MA 02601 Centerville,MA WE ARE SENDING YOU: X Enclosed _ Under separate cover via X the following: Report _Prints _Brochures Shop Drawings Specifications _Copy of Letter _Change Order Forms Please find enclosed the following for your review and approval: 1 ) four copies of a completed variance request form 2 )four copies of a septic system design plan dated June 16 2005 3 four copies of labeled dimensional floor plans, 4.)one signed representation authorization letter,and one check for$85 (variance request fee). THESE ARE TRANSMITTED as checked below: X For Approval _Resubmit Copies for Approval For Your Use _Approved as Noted Copies for Distribution As Requested _Returned Approved as Submitted Returned For Review and Comment For Your Information REMARKS Should you have any questions,please feel free to contact our office. Also,we understand the hearing date and time is scheduled for July 12,2005 providing that abutters receive notification of the hearing at least ten days prior to hearing date. Please call our office to confirm Thanks. COPY TO: File(1),Neff(1) SIGNED: Michael Ptmlentel, E.I.T. LETTER OF TRANSMITTAL JC Engineering Inc. Civil&Environmental Services 2854 CranberryHi y Highway Y ��� ,� Telephone: 508-273-0377 E.Wareham,MA 02538 ` ` Facsimile: 508-273-0367 ' q TO: Town of Barnstable DATE: 08/12/05 JOB N . 79T A 'Board-of fHealth RE: Revised Septic System UpgradePIhn 200 Main Street 225 Main Street Hyannis,MA 02601 Centerville,MA =' Mu WE ARE SENDING YOU: X Enclosed _ Under separate cover via X the Q*win Report _Prints _Brochures Shop Drawings Specifications Copy of Letter Change Order Forms Please find enclosed four(4)Revised Septic System Upgrade Plans(2 sheets total). THESE ARE TRANSMITTED as checked below: X For Approval _Resubmit Copies for Approval For Your Use _Approved as Noted Copies for Distribution As Requested _Returned Approved as Submitted Returned For Review and Comment For Your Information REMARKS Should you have any questions,please feel free to contact our office. Thanks. COPY TO: File(1),Neff(1) SIGNED: Michael Piment , E.I.T. ED RESTRICT 05-25-20 5 a 03 19� WHEREAS, UC�/S�" ",�//2��4d� of (owner's name)l5E,�'/F� 7 'S�ar�/� .�� MA (address) is the owner of located ,at Z&G� (address) MA (hereinafter referred to as and being shown on a plan entitled "Subdivision of Land"in J°j 5W121�_57,6 ,5_ MA, Property of et al, duly recorded in Barnstable_ County Registry of Deeds in Plan Book �7 9/ Page Or on Land Court Plan Number .7 WHEREAS, z_J/5,�5_ (I ,� ��/4/1� as the owner of said lot has (owner's name) agreed with the Town of Barnstable Board of Health to a restriction as to the number of bedrooms which can be included in any home built'on said lot as a pre-condition to obtaining a disposal works constructiompermit in compliance with 310 CMR 15.000 State Environmental Code, Title-ViWinimum - Requirements for the Subsurface Disposal of Sanitary Sewage; WHEREAS, the Town of Barnstable Board of Health, as a pre-condition to granting a disposal works construction permit for a septic system in compliance with 310 CMR 15.200, State Environmental Code, Title V, Minimum Requirements for the Subsurface Disposal of Sanitary Sewage, and authorizing the issuance of a building permit for the construction of a single,family home on this property, is requiring that the agreement for the restriction on the number of bedrooms in any house constructed on the lot be put on record with.the Barnstable County Registry of Deeds by recording this document, deedr I 05/1121105 15:41 15084309979 PAGE 02/03 Bk 19836 P %a335 633113 DEED RESTRICTION. WHEREAS,Peter and Janine Dallow of P.O.Box 5886,Montecito, CA 93150 are the owners of 45 Hornbeam Lane located at Centerville, MA and being shown on a plan entitled Plan of Land in Centerville, MA for A.H. Rand,duly recorded in Barnstable County Registry of Deeds in Plan Book 13, Page 73; WHEREAS, Peter and Janine Dallow as the owners of said lot have agreed with the Town of Barnstable Board of Health to a restriction as to the number of bedrooms which can be included in any home built on said lot as a pre-condition to obtaining a disposal works construction permit in compliance with 310 C.M.R. 15.000 State Environmental Code,Title V;Minimum Requirements for the Subsurface Disposal of Sanitary Sewage; WHEREAS,the Town of Barnstable Board of Health, as a pre-condition to granting a disposal works construction permit for a septic system in compliance with 310 C.M.R. 15.200, State Environmental Code,Title V Minimum Requirements for the Subsurface Disposal of Sanitary Sewage, and authorizing the Issuance of a building permit for the construction of a single family home on this property,is requiring that the agreement for the restriction on the Number of bedrooms in any house constructed on the lot be put on record with the Barnstable County Registry of Deeds by recording this document; NOW THEREFORE, Peter and Janine Dallow do hereby place the following restriction on their above referenced land in accordance with their agreement with the Town of Barnstable Board of Healthy which restriction shall run with the land and be binding upon all successors in title: Any house constructed upon the lot shall not contain more than four(4)bedrooms and we, Peter and Janine Dallow, agree that this shall be permanent deed restriction affecting Lot 8 located on Hornbeam Lane, Centerville, MA, and being shown on the plan recorded in Plan Book 13,Page 73. For title reference, see the following deed: Book 15553,Page 286. E cuted as a ed instrument day ofAQ(.40fO Peter Dillow i an• a Dall —1— it I i DOs_ I s FJ06 j,vv 3 07-1 1-20115i 3 BARNSTABLE LAMES COURT REGIST Y U l2D &b Wh y k DEED RESTRICTION WHEREAS, Mary Bailey Hash, of 3944 Baltimore Street, Kensington, Maryland is the owner of a certain parcel of land together with the buildings thereon at 1199 Craigville Beach Road, Barnstable (Centerville), Barnstable County, Massachusetts by deed froru Mary L. Mayer recorded in Barnstable County Land Court in Document No. (lam WHEREAS, Mary Bailey Hash as the owner of said lot have agreed with the Town of Barnstable Board of Health to a restriction as to the number of bedrooms which can be included in any home built on said lot as a pre-condition to obtaining a variance from the State Environmental Code, 310 CMR 15.211; WHEREAS, the Town of Barnstable Board of Health, requires that said restrictions be put on record in the Barnstable County Registry of Land Court; \ NOW, THEREFORE, Mary Bailey Hash does hereby place the following restriction on their above-referenced land in accordance with their agreement with the Town of Barnstable Board of Health, which restriction shall run with the land and be binding upon all successors in title: Until such time as technology changes and the Barnstable Board of Health changes its regulations or otherwise grants permission, said premises at 1199 Craigville Beach Road, Centerville may have constructed upon the lot a house containing no more than four (4) bedrooms maximum and agree that this shall be a permanent deed restriction affecting said premises. For title of Mary Bailey Hash see Document Nol Executed as a sealed instrument this day of , 2005. MARS'BAIL "HASH OFFICES OF 1 Z.ALGER.P.C. 3KER ROAD l BOX 449 'RVR1E.MA 535-0449 O D p Bk 20505 Ps261 JW-82789 1. 1-25-2005 a'1 08 2 3 7m r RESTRICTION WHEREAS, THOMAS J. FUREY and CYNTHIA A. FUREY, of 10 Wayside Lane, West Barnstable, Massachusetts 02668, applied to the Barnstable Board of Health (the "Board") for a sewage disposal system construction permit (the "permit") for a sewage disposal system (the "system") for premises at 10 Wayside Lane, West Barnstable, Massachusetts (the "premises); and WHEREAS a variance from the requirements of Title 5 of the State Environ- mental Code (310 CMR 15.000) was required for issuance of the permit; and WHEREAS the Board imposed as a condition of granting said variance for property located at 10 Wayside Lane, West Barnstable, Massachusetts that a Restriction be recorded at the Barnstable County Registry of Deeds, and WHEREAS the Board granted the permit subject to the condition that a notice of said variance and Restriction shall be recorded at the Registry of Deeds, NOW THEREFORE, We, THOMAS J. FUREY and CYNTHIA A. FUREY, hereby declare that the premises located at 10 Wayside Lane, West Barnstable, Massachusetts as described in a deed recorded in the Barnstable County Registry of Deeds in Book 9840 , Page 134 , is subject to the variance described above and to a condition of the variance that if the owners of the property located at 10 Wayside Lane, West Barnstable, Massachusetts, would like to increase the size of the septic system in excess of a four bedroom system in the future or if said owners would like to increase the bedroom capacity of the system in a manner which complies with Title V of the State Sanitary Code and the Barnstable regulations, that they will apply to the Barnstable Board of Health for said authorization. This declaration shall be binding upon the undersigned and all successor owners of the premises. d seals this da o /, 2005. Witness our hands an s y OMA Y HIA A. Y WITNESS 1 UJ 342 a 7 5 J...73 ' DEED RES TPJCT C u WHEREAS, Merle L. Sleeper and Edward L. Sleeper, Trustees of the Seaside NomineeTrust, u/d/t dated September 25, 1992 and recorded at the Barnstable County Registry of Deeds in Book 6240, Page 87, Of 780 Boylston Street, Boston, MA is the owner of 15 Cross Way, Barnstable, (Hyanniaport), MA, {hereinafter the "Property"), recorded in Barnstable County Registry of Deeds it Plan Book 8ae 092 eed duly WHEREAS, Merle L, Sleeper, Trustee and Edward L. Sleeper, Trustee, as the owner of said lot has agreed with the Town of Barnstable Board of Health to a restriction for three (3) bedrooms which can be included In,any home built on said lot as a pre-condition to obtaining a disposal works construction permit in compliance with 310 CMR 15.0()0 State Environmental Code, Title V, Minimum Requirements for the Subsurface Disposal of Sanitary Savage; WHEREAS, the Town of Barnstable Board of Health, as a pre- condition to granting a disposal works construction permit for aseptic system in compliance with 310 CMR 15.200, State Environmental Coda Title V Minimum Requirements for the Subsurface Disposal of Sanitary Sewage, and authorizing the Issuance of a building permit for the construction of a single family home on this Property, is requiring that the agreement for the restriction on the number of bedrooms in any house constructed on the lot be put on record with the Barnstable County Registry of Deeds by recording this document, NOW, THEREFORE, Merle L. Sleeper and Edward L. Sleeper, Trustees do hereby place the following restriction on his above- referenced Property In accordance with their agreement with the Tows,of Samstable Board of Health, which restriction shall run with the Property and be binding upon all successors in title: 1. 15 Cross Way may have oohs#rutted upon the lot a house containing no more than three (3)bedrooms as exists as of this document date. e Merle L. Sleeper and Edward L, Sleeper, Trustees agree that this sha ll be a 'permanent deed restriction affecting Parcel 042 located on Map 245 known as 15 Cross Way, Barnstable, (Hyannisport), MA, and being shown on the plan recorded in Plan Book 163, Page 149 as lots 530, 532 and 532A as Plan of Land in Seaside Park, Hyannisport, Mass. / Executed as a sealed instrument this Y aY of December, 2005. / L lee e T tee Edward L, Sleeper, Trustee j o,� Pl STATE QF FLORIDA ss Decembers 2005 On this 4 day of December,2005, before me, the undersigned notary public, personally appeared Merle L. Sleeper, TrusteeOcedino, esaid, proved t me thro gh satisfactory evidence of identification, which w to be the person whose name is signed on the or attached documen , and�/ 1±+ acknowledge to me that he/she signed it voluntarily for its stated purpose. ��Q a.� p+,ire ?� �••:.►11��1p�%•;°i ��. p -Xq ODD142370ZZ /fife ZI!'1!iTN110,```,`\ I GENERAL NOTES -PROVIDE (H-2,))CAST IRON MANHOLE T4"PVC VENT PIPE 314"TO 1-1/2'DOUBLE WASHED STO0 1-0 CROWN OF PIPE 2"CAP TOP OF FOUNDATION = 99•�' j FRAME 8 COVF�'2 TO FINISHED 1. UNLESS OTHERWISE NOTED,ALL SYSTEM COMPONENTS AND CONSTRUCTION Y OF 1!8•TO 12"DOUBLE WASHED ST )W_ 2" INSPECTION PORT TO GRADE ON ALL LATERALS METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE. GRADE OVER ALL COVERS (COVER -- -`--- - - ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. EMBOSSED Vt'TH "SEWER") _-_ -----T---- --_ - ----- FINISH GRADE ( 18" FINISH GRADE Q FND. EL.= 96•3 ± OVER TANK EL 96._5� -_97.4� 12"MIN./36"MAX. ; TOP OF s.A.S = �,�' 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD _ - - -- - W MIN. ; OF HEALTH AND THE DESIGN ENGINEER tz•MIN. TOP EL. 2"SCH. 40 -- --- 3/8•PERFORATION TO BE PLACED AT THE 3. 4"SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHAM F 3s"MIN. 95.42 TO LEACHING BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. EXIS CI PIPE FACILITY CONTINUOUS PITCH BACK TO TANK CROWN OF THE PIPE AT THE END OF FORCE MAIN EACH LATERAL PRIOR TO THE ELBOW 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN _- :-• 2" SCH-40 ELEVATION = 96.59' FOR A DISTANCE OF 15'AROUND THE PERIMETER OF THE SAS. � 4"SCHEDULE 40 PVC __1 112" PERFORATED LATERAL " BOTTOM OF TRENCH TO BE LEVEL EL. = 95-$Q' � UNLESS A 40 MIL GEOMEMBF2ANE LINER IS PLACED AT LEAST FIVE FEET FROM S.A.S. SI_�_ 1%,TMn 6 3 2" MANIFOLD S = 0.50% 45° ELBOW SET LEVEL. INV. ELEV. = 96.30' - -- 12" �" AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 3•DROP MIN' BACK TO FORCE MAIN ) 5 MIN. 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. ' INV (out) ,�" INv ((out � ON -_ INV (Out) FIELD PROFILE � 95.52'* •8- INV o ) 14 93.67_' - a. -- 6- THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. N�) TO SCALE GROUND WATE ELEV_- 90.78 ---- 89.75' LIOt�io --- - -- P N - - - 7- LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO INV (in) - SET INVERT OF 4"PERFORATED LEVEL SCH. 40 PVC VENT PIPES AT OR -- FINISH GRADE OVER LEACHING FIELD= 97.59' - 97.69' BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR ` 89.25 6"CRUSHED STONE CONCRETE THRUST BLOCK i INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING 94.00 OVER MECHANICALLY ABOVE CROWN OF LATERAL SLOPE Q 2% MIN. OVER SYSTEM • , _ __ _ -_ . _ APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. .. - . ,.• - - --• - - . - .. •.- . COMPACTED BASE _ 3/f3" PERFORATION hT 7 -- -_------- ---__._ - .-. _ _ __._ --- ------- --------_ _ _ _ _._ � � 10 1 T 3/8" PERFORATION AT 5 - 4 OUTLET TEE $ � *wm � O'Gt_UCK (TYP.) O'CLOCK (TYP.) TOP OF SA S. = 96.59' 12'MIN. I 8 ELEVATIONS BASED ON ASSUMED DATUM OF 98.33'OBTAINED FROM TOP OF o 36"MAX CENTER BACK OF CATCH BASIN ON MAIN STREET AS SHOWN ON PLAN. APPROXIMATE ELEVATION. GAS BAFFLEV 2' 5' 10 PEASTONE I 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION INVERT 2"OF 1/8" TO 1/2" l-lf2"PVC �;C�NTRAC UR SHALL v"FRIFY ` NOTE: (TYP-) (TYP ) PERFORATED PIPE THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE EL.--95.80' DOUBLE WASHED � MOLD PRfCAF: TANK WITH RUBBER 2' AT 1-868-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY M, GASKET FOR INLET AND OUTLET 7 SOun MANIFOLD STONE 6"EFFEC IIVF i DISCREPANCIES TO THE DESIGN ENGINEER. SLOPE 0.50%BACK 2.5 DEFT, 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONCRETE KNOCK©LTS p`JSTALLER TO ALSO TO FORCE MAIN �'� - 2 5' 9' + - + LENGTH 12-2" WIDTH 6'-8" DEPTH 6'-2" - STRUCTURES SHALL BE MADE WATERTIGHT. USE HYDRAULIC CEMENT AT JOINTS INVERT - 3/4' TO 1-1/2'DOUBLE _ TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE TO ENSURE WATER TIGHTNESS. Ft_= s5 �8 2 _� �' WASHED STONE TO 2.5 2 i I11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR 7 O'Ct.OCK _. 5,O`CLOC:K 2' S' 2' ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH ^ 4"PVC VENT PIPE 1-1/2"L AT>ERAL(TYP.) CRO'V0 OF PIPE 9' 5' MIN. PROPOSED COMBINATION 1500 GALLON SEPTIC _A►NK � ��'- DETERMINATION FROM APPROPRIATE AUTHORITY. A LAtERAL CROSS-SECTION 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS 1 ( ` PLAN VIEW FIELD END VIEW A-A GROUND WATER EL 90.78' I LOCATED UNDER PAVEMENT, DRIVES OR TRAVELED WAYS IN WHICH CASE 500 GALLON PUMP CHAMBER (H-20) NOT TO SCALE NOT TO SCALE 140T TO SCALE THEY SHALL BE WITHSTAND H-20 LOADING. -. _ - _-- _ -- 3 E WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, UST AND -PROPOSED 1-1/4" 1_EEOFPAVE IGN DATA • ,o Q O TEST PIT DATA FINES. D AA AA^^ ! I `�MENT 1 • . 14, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND 'V� l�V STREETEXISTING LIGHT PERFORATED SCH. _ • • . � AGENT: DI><�Id W. Stanton. R.S. i MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF Benchmark 40 LATERAL NUMBER OF BEDRCXN,MS (ASSESSORS) 3 , • • aUNSUITABLEi t EXISTING LESS POOL TO BF_. Center Bade of CS POST TO BE ' . • 4 EVALUATOR: Pirr►entel, E.I.T.ET LEACHING FACILITY REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN I f'I IMPFD AND REMOVED ALONG 1953:OtltvT Y LAYOUT - PUBLIC) EXISTING WATERLINE NUMBER OF BEDRO,)MS(DESIGN) _. 3 • , • 1 EIPv. = 96.33' ( REMOVED AND • •' • ' r N 6, 2005 COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN LOCATION OF MONITORING WELL IVITH SPOILED SOT OFFSITE UBLIC) REPLACED PROPOSED 4" TO BE REMOVED AND DESIGN FLOW •• •• i USED FOR GROUNDWATER I (Assumed) PERFORATED REPLACED AS SHOWN --- GAI.r't�AvrE3FnRnnM i • • DATE: 7 AND DISPOSED OF N '- �� ACCORDANCE WITH 310 CMR 15.255(3). TOTAL DESIGN FLOW __- 330 C�AUUP.Y • TEST PIT#: 1 DETERMINATION �"�(,CURDANCE WITH TITLE � - PVC VENT PIPE ° `�-- - � � a•_ 7 M - � 115. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN DESIGN FLOW x 2W k, = 66U GALJDAY ELEV TOP = 96.50 _ _ ___-- - =•. _ _�-- EXIST. CB -PROPOSED WATERLINE i ---- SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK USE PROPOSED 15QQ__- _ GALLON SEPTIC TANK ! • • . I 4 VENT - '` 96x `_96x6 / (MAINTAIN 10' MIN - _ ELEV WATER=_ 90.78' ` 16. PROPOSED PROJECT IS LOCATED WITHIN: PROPOSED 4"SCH. 0 PVC VE _ - 25% REDUCTION(L(-CAt UPGRADE APR - 82.5 GAL/DAY (LOCATION TO BE CONFIRMED / AWAY FROM SAS) i a ASSESSORS MAP 209 PARCEL 43 / REDUCED DESIGN F'..i)W = 247.5 GALJDAY _ -- PERC RATE _ <2 min/in BY HOMEOWNER)- _ -X-X - X-XI i ;. I.;.� x p 7 1 - EDGE OF p .•• • OWNER OF RECORD: JOAN ANN CRIVELLI 1� 36 I uy� •X-x AVEMENT • • n, DEPTH OF PERC'= 72"-90" -- 96� ~---_ a : • . ADDRESS 3300 BINNACLE DRIVE, 8-103 ° 50-E Q X x- x'X-x-- ! - INSTALL 9 x •LEACHING FIELD - (I - -- ��' x d X`XyT k� 97x0 • • • / TEXTURAL CLASS 1 I \ � 87x5 • • • NAPLES, FL 34103 X--X, PROPOSED 2"SOLID 96x8 \ �. �: ;• 97x1 X -X` X--x_X- FENCE SIDEWALL CAPP;Ct i"( f ® f '. •• �1 0 -� 96.50, I FEMA FLOOD ZONE C 'y X X-x LINE NO SIDEW ALI_ AREA CREDIT TAKEN D t4f rY, ' SCH. 40 FORCE MAIN / ' X- X_ « • • • �-+'� I AS SHOWN ON COMMUNITY PANEL# 250001 0005 C BOTTOM C�APA64TY - 7. PLAN REFERENCE: I \ EXIST. �/ j _� '.- 3 20g-55' 96x7 (LENGTH x WIDTH)(A 74 OPDMQ.FT ► GAUDAY ` ' Fill 1. PL. BK. 130, PG. 151 _ _ ` _ 18- DEED REFERENCE: D -_ �� � $ 1 A -. : ,..,,. . . :' ; .- - - .... ._ S80°5 " --� 38'x 9') 74 GAi../SQ.FT.) = 253.08 GAUDAY . 66" - - 91.00' 35 D / 3 . -... = `. "',!• ..: 0' 0 E ` * r , �olMtty Sand 1. DEED BK. 3454, PG. 65 / * I A -- �` '' " �' J 11 - '� . 68" - -10YR 3/2 90.83' 119 ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. _ -94 - I TOTALS: I 58 15'0G"E 916x5 �-*•�rr ~''�- EXISTING STEPS _ • • .j �20. PROPERTY LINE INFORMATION IS APPROXIMATE, ONLY. THIS PLAN IS TO BE USED ONLY .` _ --- c . ` )i', ' y -•�:c. 3 , �� TOTAL LEACHING A14EA 342.00 SQ.FT. I . . `C�3 s 2 , TO BE REMOVED O REPLACED c�x TOTAL LEACHING OPACITY 2g3•08 GAL/DAY 41 • " . i B l.aatny Sand I FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY 1 AN E - 0 1r1�R5/6____ _ 90 50' )^OR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. l9 5 O y �� - c 'r -{ " ' PetC 21. IN ACC DANCE W17N 310 CMR 15.401-15.405 THE FOLLOWING LOC/LL.UPGRAQF_ ,ri>nnty c 1 - •_- _t 8900, I A B=Arm( 'Ji' . r AC;K PROM T T PROPERTY LINE ftk _ -s2-- r�'` 14 "� - REQUIREMENTS r '*�� �" g O ' G ETwo . f~4A T . ', 9F FROM \ \ �_ I - r , ` • 98' 88.30' (2 ) A 14-V VIAIIIAWC E (2'0' 5 9')VOR THE 9FTRA�C K FROM FOUNDATION TO THE f3vL'V � � l 50 WETLAND OFFSET I � DOSING REI.)t.H+2EL) 4 CYCLE / DAY C FMK"�m � GARAGE 8.2' i xu 253.08 GPD/4 = 63 GAUCYCLE p, 2.5Y 6/6 PROPOSED LEACHING FACtUT'y l f' I Ir + (3.) A 25% REDUCTION IN THE REQUIRED LEACHING SUBSURFACE AREA DESIGN #225 i _ �„ l \ � -!- . • � DISTANCE REQUIRED BETWEEN PUMP __ _ _ GE SLAB AO.g'-- __ __. 10. _ / / ��, REQUIREMENTS. U o , ON AND PUMP OFF LOATS: (4.) A 1 8'VARIANCE (10' 8 2') FOR THE SETBACK FROM THE GARA • EXISTING �BVW 63 GAUCYCLE 125 GAUFT = 0.50 FT/CYCLE 12(r 86.50' FOUNDATION TO THE PROPOSED SEPTIC TANK/PUMP CHAMBER. IBtNV ' 3-BEDROOM / / 11 (USE 0.52' TO PROV10E. FOR 2 GALLONS OF BACKFLOW) " Mtxliboled a M 0 Sys end (5.) A 9.9'VARIANCE (50'-40.1')FOR THE SETBACK FROM THE BVW TO THE PROPOSED EXISTING DRAINAGE USGSLOCUS EASEMENT(BK 315, PG 7)�_ DWELLING � Iot>IrM ft �W bv�el��®� LEACHING FACILITY. I , \ • 9•x • �a.`'' (6.) A 1.9'VARIANCE (10'-8.1') FOR THE SETBACK FROM THE SUBSURFACE DRAIN TO >>ORAGE REQUIRED ABOVE WORKING l EVEL_ 247.5 GAL. SCALE: 1"= 1000' 90.78• Sse�folr mor�itorir►9 well THE PROPOSED LEACHING FACILITY. l 94x / T0F=99.V �96-_.._ � STORAGE PROVIDED ABOVE WORKING LEVEL- 360 GAL. � 22. THE FOLLOWING LOCAL VARIANCES ARE REQUESTED FROM THE BARNSTABLE CODE IPROPOSED HAYBAL MAP 209 M O I`J I TO R I N G BOARD OF HEALTH REGULATIONS ARTICLE 1, SEC.Kso-1: M (1.) A 59.9' VARIANCE (100' -40.1') FOR THE SETBACK FROM THE BVW TO THE g , �� dl_ LINE(TYP) / ' PARCEL 43 INS-IALL 1-1/4 PVC: TO HOUSE .JOINTS TO BE MADE: `A Ic t- DATA PROPOSED LEACHING FACILITY. Nl I 94 I ENCLOSED _ WATERTIGHT WIRE PUMP AND FLOATS TO SIMPLEX WELL EL` (2.) A 59.2 VARIANCE(100'-40.8)FOR THE SETBACK FROM THE BVW TO THE 18,680 S.F. t CONTROL. PANEL No. 1-CC2 NEMA-1 MFG. HOOVER PROPOSED SEPTIC TANK/PUMP CHAMBER. PROPOSED PORCH VW 10 l / (0.43 Ac) INS Rl1MENTS. ---- _ ELEV TOP OF 1NEL_ PIPE = 96 --- ___ LEGEND C A f n o COMBINATION 1500 / C C 1 V lJ MAP 208 ��l SEPTIC TANK & 500> NEMA 4 JUNCTION BOX CORROSION RESISTANT HOISTING CABLE 7 x 19 STAINLESS STEEL _ _ _ _ _ _ _ _ _ _ _ _ I PUMP CHAMBER (F / N & LIQUID-TIGHT CABLE CONNECTORS 1/8'DIA./ 1,760 LB. STRENGTH - - - - So- - - . EXISTING CONTOUR PARCEL 102 i / \ SUPPORTED::ONNE CTORS SUPPORTED BY 1-1/4" READING# 1 PROPOSED SPOT GRADE j \ DEPTH OF WATER'= 75' ® f PROPOSED CONTOUR N/F BOtt.ES l � � - - . � - PROPOSED 38'x 9' � DECK / PVC LONIJUI' JOINTS TO BE MADE WATERTIGHT 2 BALL VALVE w/UNIONS SCH. 80 PVC PROPOSED FIELD / GEORGE FISHER CO. MODEL NO. 560 ELEV WATER= 90.53' -r� l DATE _ _ 03-30-05 E/T/C EXISTING OVERHEAD UTILITIES l r 1- -_92� WETLAND LINE 3. 2"SCH. 40 TO LEACHING FACILITY - - - - - - - W V/ -- EXISTING WATER SERVICE LINE IREMOVE & RERAG&_UNSUITABLE READING# 2 l BVW 4 MATERIAL R E SOILS WITH` / N o EXISTING GASLINE CLEAN COARSE SAND / DEPTH OF WATER'- 73' W W PROPOSED WATER SERVICE LINE \� -92- .� in OLD PRECAST TANK WITH RUBBER ELEV WATER= - 90.70' GAS �/ -�� BVW 9 TREE LINE T P oN - GASKET FOR INLET AND OUTLET DATE = _ - 04_1�- - - I TEST PIT LOCATION PROPOSED 40 MIL KNOCKOUTS. INSTALLER TO ALSO USE - - - - - _ - - - APPROXIMATE GEOMEMBRANE LINER • `° READING# 3 PROPOSED 1500/500 SEPTIC TANK LOCATION OF I gay 5 �. .�. HYDRAULIC CEMENT AT JOINTS TO ENSURE __ DRAINAGE DITCH ` r?`fin F _��* WATER TIGHTNESS. O O O PUMP CHAMBER (H-20) DEPTH OF WATER= 73' EXISTING �` BVW 1 _ DRAIN PIPE ,r NOTE: 'SCH.40 TEE w/CLEAN-OUT CAP ELEV WATER 90.70' PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE BVW 6 ENTIRE PROPERTY IS NOT LOCATED WITHIN A DES s ANGLE CONTROL FLOATS DATE = 04 20-05 - PROPOSED 2" SOLID SCHEDULE 40 PVC PIPE APPROVED ZONE 11 AND IS NOT LOCATED WITHIN TOWN S 073618) k�o ry 2' BALL CHECK VALVE SCH. 80 PVC 100 - - - - = - - - - - - - - PROPOSED 4" PERFORATED SCHEDULE 40 PVC PIPE DESIGNATED ZONE OF CONTRIBUTION. 1- PUVP ONIOFF 120 ACTIVATION o P.S.I. FLOWMATIC MODEL No. 208S READING# _ 4 ____ _ PROPOSED 2"PERFORATED SCHEDULE 40 PVC PIPE 2: ALARM ACTIVATION 1/4"WEEP HOLE IN DISCHARGE PIPE DEPTH OF WATER= 72" 2"SCH. 40 PVC DISCHARGE PIPE ELEV WATER=- 90.78' I EXISTING LIGHT POST SITE PLAN NOTE. TANK TO BE WATERTIGHT DATE = 05-04-05 _ 1 O EXISTING DRAIN MANHOLE ---- ___ CERTIFIED BY MANUFACTURER (ACME ARNES SE51 PUMP, 0.50 H.P., 120 V, 1750 _ _ _ _ _ _ _ _ _ MAP 209 SCALE: 1"= IV PRECAST OR APPROVED EQUAL). RPM, 2" DISCHARGE PASSING 1-1/2"SOLIDS READING# 5 - ® EXISTING DRAIN CATCH BASIN PARCEL 047 (IMP. DIA. 5.25")OR EQUAL DEPTH OF WATER-= 73" Nn TOWN OF BARNSTABLE I (4 �_ ELEV WATER= 90.70' _ REV. DATE BY APP'D. _ DESCRIPTION _ MAIN Sr DATE = 05-11-05 REEr PROPOSED COMBI NATION 1500 GALLON SEPTIC TANK / - _ - - - -- - - - - - _ - PROPOSED SEPTIC SYSTEM UPGRADE S u53'S0"F - - -- -- 5) 08 55 (3 Note: I PREPARED FOR: 500 GALLON PUMP CHAMBER (H-20)t w Used 90.78'as elevlttion of ground water for design t NEFF _ SSS° DESCRIPTION HC GC 6) -_ _--.--------.------ -----_ _.._ _-----_-.------ --- ---- -- RESERVED �' #225 So. , �'(" O 2) HC BOARD OF HEALTH USE I JIOANED AT ( 00 $ . MAP 209 634q• o f SEPTIC COVER IN (1) 16.1' 14.6' #225 BUJ BUOYANCY CALCULATIONS MAP 208 o PARCEL 43 {1� EXISTING 225 MAIN STREET PARM 102 Z SEPTIC COVER OUT(2� 13.5' 13.1' C E N T E RV I LLE, MA 02632 wF BOLES 1500/500 COMBINATION TANK(H-20) p 3-BEDROOM 2 J SCALE: 1 INCH - 10 FT DATE: JUNE 16,2005 By S69 9q` LEACHING CORNER (3) 19.1' 12.3' DWELLING HIGH GROUNDWATER EL.= 90.78' N0,4T 17 1T�' TOF=99.1` BOTTOM OF H-20 TANK EL. =89.25' 0 5 10 20 'a FEET a tiS7O MAP 209 LEACHING CORNER (4) 23.6' 19.9' WATER DISPLACED=(90.78'-89.25')x 12.1T x 6.67' = 124.20 C.F. FOFo/T NV DAVIS L002 LEACHING CORNER (� 25.1' 49.8' WEIGHT OF DISPLA�,ED WATER = 12420 C.F x 62.4 LB/C.F. =7,750 LBS ?fir J�HN i PREPARED BY: _T cyWEIGHT OF H-2_C TPNK 18,000 LBS u �H�JR JC ENGINEERING, INC. LEACHING CORNER (6) 20.9' 47.3' WEIGHT OF SOIL= 167' x 12.17'x 1.08' = 87.67 C.F. x 110 LB/C.F. =9,643 LBS CML 2854 CRANBERRY HIGHWAY --- WEIGHT OF H-20 Tf NK +WEIGHT OF SOIL = 18,000 +9,643= 27,643 LBS N 41807 LOCUS PLAN I 27,643 LBS > 7,750 1 BS (ACCEPTABLE) STEW EAST WAREHAM, MA 02538 SWING I N G TIES S "` _ 508.273.0377 3CAL F - 6C' I i Drawn By: MCP I Deigned By.MCP Checked By JLC JOB No.7S2 SCALE: 1'= 20' r LIMP OUTS TO BE RAISED TO WITHIN 6"OF BLOWER WITH HOOD UNIT PLACED ON GRADE GENERAL NOTES TOP OF FOUNDATION FINISHED GRADE. PROVIDE H-20 C.I.FRAME AND (BY BIO-MICROBICS) 4" PVC VENT PIPE 3/4"TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 2" CAP ELEv.- 99.1' COVER TO GRADE OVER ALL PUMP OUTS ON A SEE DETAIL SHEET 2�` PROVIDE H-20 CAST IRON MANHOLE FRAME& WITH CHARCOAL FILTER 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION CONCRETE BASE OR CONCRETE RISER. COVER TO FINISHED GRADE OVER ALL COVERS 2" OF 1/8"TO 1/2" DOUBLE WASHED STONE 2" INSPECTION PORT TO GRADE ON ALL LATERALS (COVER EMBOSSED WITH"SEWER") _ _ __ __ METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE FINISHED GRADE EXISTING DRIVEWAY PAVEMENT FINISHED GRADE 2" SCH. 40 ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. FINISHED GRADE 18" 12" MIN./36" MAX. TOP OF S.A.S. = 96.59' 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD @ END. = 96.3± 3"MIN.VENTING PIPE OVER S.T.EL.= 97.1 ± OVER P.C.EL.= 96.6±�� TO FIELD 3" MIN. OF HEALTH AND THE DESIGN ENGINEER. 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL 12"MIN. I I ELECTRICAL �- 3/8" PERFORATION TO BE PLACED AT THE CROWN OF THE PIPE AT THE END OF BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. 36"MAX. MOUNTTE - -- ---- -- CONDUIT(To CONTINUOUS PITCH BACK TO TANK 2"MIN.B 0WER PIPING EACH LATERAL PRIOR TO THE ELBOW4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN HARDW BLOWEREXISTING 4" JOIN CONTROL 2" SCH. 40 FORCE MAINI SEE NOTE 9. I ELEVATION = 96.59' FOR A DISTANCE OF 15'AROUND THE PERIMETER OF THE SAS. SHEET 2 MUST SYSTEM`SEE 1-1/2" PERFORATED LATERAL BOTTOM OF TRENCH TO BE LEVEL EL. = 95.80' 12" UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACED AT LEAST FIVE FEET FROM S.A.S. SEWER PIPE ( ) WATERT i' NOTE 4. 0 45° ELBOW SET LEVEL INV. ELEV. = 96.30' F (SHEET 2) 2" MANIFOLD(S = 0.50 /o) AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. PROPOSED 4" I I I BACK TO FORCE MAIN FIELD PROFILE SEWER PIPE i \ i - -- TOP= 5' MIN. 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. j 93.80' 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. to _ 3'MIN. 04 a"SCH.40 PVC NOT TO SCALE GROUND WATER ELEV= 90.78' MIN.SLOPE@2% n! 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO SLOPE 1%min. SET INVERT OF 4" PERFORATED LATERAL 1: 23.5' LONG WITH SCH. 40 PVC VENT PIPES AT OR BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INV (out)=95.5'* LO FINISH GRADE OVER 6 PERFORATIONS TOTAL LATERAL 2: 21.2' LONG WITH ABOVE CROWN OF LATERAL INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING s"DIA.HOLE ' � 92.75 F LEACHING FIELD = 97.59 - 97.69 (SEE DETAIL 3/8" PERFORATION AT 5 PERFORATIONS TOTAL ° APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. INV (out)=93.00' SEE NOTE 3�- I SHEET 2) TOP OF S.A.S. = 96.59' SLOPE @ 2/°MIN. OVER SYSTEM (SHEET 2) - I - 5 O'CLOCK (TYP.) 12" MIN. 8. ELEVATIONS BASED ON ASSUMED DATUM OF 96.33'OBTAINED FROM TOP OF 92.55' INT. N A 3/8" PERFORATION AT 36" MAX. CENTER BACK OF CATCH BASIN ON MAIN STREET AS SHOWN ON PLAN. SETTLING N TREATMENT BGT co 2' 5' 10, 7 O7 'CLOCK (TYP.) z - 88.30' - _ ____-__F__ -_ _�_ _-_ _- -_ __ PEASTONE DOUBLE WASHED -- 1-1/2" F VC 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION ZONE -1 ZONE o _ EXT. INVERT (TYP.) (TYP.) 2"OF 1/8"TO 1/2" ' SEE NOTE 6 MicroFAST® BOT- EL.-95.75' , PERFCRATED PIPE THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE 10.2' (SHEET 2) INSERT MODEL 0.5 87.80' ' 3 i AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY 99V9*(BY BIO-MICROBICS 92.30 2"SOLID MANIFOLD STONE I _�____ ---_---- -----------------�---- -------- --- SLOPE 0.50%BACK ----------------%=------------- --%=------- i 6"EFFECTIVE DISCREPANCIES TO THE DESIGN ENGINEER. LENGTH 11'-0" WIDTH 6'-2" HEIGHT 6-0" LENGTH 9'-0" WIDTH 5'-3" HEIGHT 6'-0" TO FORCE MAIN 4' 10' + •' + DEPTH 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONCRETE (TANK DIMENSIONS PER ACME PRECAST) (PUMP CHAMBER DIMENSIONS PER ACME PRECAST) INVERT - -------------------_------- ------ ---- --- -� --- STRUCTURES SHALL BE MADE WATERTIGHT. EL.=95.80' � � 3' �� �_ 3/4"TO 1-1/2" DOUBLE 2' 2' TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE ___ _ WASHED STONE TO 3' - 4' 3' 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR TANK SHALL BE WATERTIGHT TANK SHALL BE WATERTIGHT �4" PVC VENT PIPE - 1-1/2" LATERAL (TYP.) 7 O'CLOCK 5 O'CLOCK CROWN OF PIPE 10' 5' MIN. ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH CONCRETE THRUST BLOCK 19.5' 5.8' DETERMINATION FROM APPROPRIATE AUTHORITY. A LATERAL CROSS-SECTION 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS 1500 GALLON H-20 SEPTIC TANK W/ MICROFAST INS_ ERT '1000 GALLON H-20 PUMP CHAMBER PLAN VIEW FIELD END VIEW A-A GROUND WATER LOCATED UNDER PAVEMENT, DRIVES OR TRAVELED WAYS IN WHICH CASE _ _-_NOT TO SCALE NOT NOT TO SCALE E'_EV.- 90.78_ TO SCALE NOT TO SCALE NOT TO SCALE - THEY SHALL BE WITHSTAND H-20 LOADING. DESIGN DATA : •• •. • , '. • 13- DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND EDGE OF PROPOSED 1-1/2" - - PA-=NT , 00 • . . . `} C6 © TEST PIT DATA STREET PERFORATED SCH. _ f • • , 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND EXISTING CESS POOL TO BF Benchmark MAIN EXISTING LIGHT 40 LATERAL NUMBER OF BEDROOMS ASSESSORS 3 AGENT: David W. Stanton. R.S. (ASSESSORS) � �7'"�^�a, � UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF PUMPED AND REMOVED ALONG, Center Back of CB 1953 CO POST TO BE EXISTING WATERLINE NUMBER OF BEDROOMS (DESIGN) 3 ••' . Q: "�...+ EVALUATOR Michael Pimentel, E.I.T. LOCATION OF MONITORING WELL Elev. -96.33' ( COUNTY LAYOUT- PUBLIC) REMOVED AND PROPOSED 4" ;� � . .• . • LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN WITH SPOILED SOIL OFFSITE' ) TO BE REMOVED AND DESIGN FLOW 110 GAL/DAY/BEDROOM '• * •• • ' •• 4 DATE: January 6, 2005 COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN USED FOR GROUNDWATER (Assumed) REPLACED PERFORATED ' AND DISPOSED OF IN i REP'LACED AS SHOWN TOTAL DESIGN FLOW 330 GAUDAY • • • BM 6� • •\� • . ACCORDANCE WITH 310 CMR 15.255(3). DETERMINATION ACCORDANCE WITH TITLE V PVC VENT PIPE • • l TEST PIT#:_ 1 DESIGN FLOW x 200 % = 660 GAL/DAY • �` �� 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN EXIST. CB PROPOSED WATERLINE ;• �' • ELEV TOP= 96.50' SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. - USE PROPOSED 1500 GALLON H-20 SEPTIC TANK • a, ; PROPOSED 4"SCH. 40 PVC VENT ---�_96x6 (MAINTAIN 10 MIN.AWAY FROM SAS 50% REDUCTION LOCAL UPGRADE APR. - 165 GAL/DAY �"-- Cf1W t"`j ELEV WATER= 90.78'* 16. PROPOSED PROJECT IS LOCATED WITHIN: (LOCATION TO BE CONFIRMED � - ) ( ) a 1 } � ASSESSORS MAP 209 PARCEL 43 BY HOMEOWNER) X - - X-XI / _ EDGE E REDUCED DESIGN FLOW- 165 GAL/DAY . -_--. - ' • PERC RATE _ <2 min/in t� 36.pg I / >> 9 X1 X-X-X- F PAV MENT • • _. ' y�., ; ! • a•••* ' • tf/�l • DEPTH OF PERC - 72"-90" OWNER OF RECORD: JOAN ANN CRIVELLI S80 53'S0„E / x X-X-X- i 96x7 INSTALL A 224 S.F. LEACHING FIELD • _ _ °i/ � � •�• /! ' •• �' ADDRESS: 3300 BINNACLE DRIVE, B-103 �` a I X-XyT 97x0 ^ t,C� !/ TEXTURAL CLASS: 1 97x5 ,X-X _ • _ _ . :..r-t� •�+ � /� • NAPLES, C 34103 `r 9 1 X X X�X-X-X- FENC SIDEWALL CAPACITY ; ` ' ' • • •` i �' FEMA FLOOD ZONE s66°p1 / 96x8 / 0 X X-X X X XELINE NO SIDEWALL AREA CREDIT TAKEN �1. � an err y • • • �� � �• � 0 96.50' oo� o� / ; i;• • � + AS SHOWN ON COMMUNITY PANEL# 250001 0005 C 5 -- / 25.3' BOTTOM CAPACITY .MIN ,, • `' '' 17. PLAN REFERENCE: EXIST. °�pOo�� O o :_` - 10 1' 208.55' 96x7 (AREA) (0.74 GPD/SQ.FT.) = GAUDAY • ° ^`` ' '�� C FIII 1. PL. BK. 130, PG. 151 D DMH 5`b \N o S80°53- (224) (0.74 GAUSQ.FT.) = 165.8 GAUDAY • . y"•� t 66" 18. DEED REFERENCE: �� Loamy Sand TP 1 O .- - :_ ---.. - � -.�� :�'�, �- 50 E •� ,•� • __,..-.-� � � �►,,,,:�?. ,� 91.00 \ D 96x5 + �•� :,p� ? 10YR 3/2 1. DEED BK. 3454, PG. 65 . - -�...- 684°15'00"E --_94\ - -- . - - •. - --_ 68 90.83 ---- - i .� - -�.-'- -- - ' ��".-'� � �� � EXISTING STEPS TOTALS �• � : � � � 19 ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. ~� o • fl 20. PROPERTY LINE INFORMATION IS APPROXIMATE, ONLY. THIS PLAN IS TO BE USED ONLY 35.42' w \ ^0 19 5, �� TO BE REMOVED ,�E/ TOTAL LEACHING AREA 224.0 SQ.FT. ti • ; ; •' » • Loamy Sand FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY } o 97x3 / AND REPLACED E/S�c TOTAL LEACHING CAPACITY 165.8 GAL/DAY p '�" ,B 'no 10YR 5/6 90.50' FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 72 a 96x5 - / _ r g o 96 97x3 j / I ' p • Perc 21. IN ACCORDANCE WITH 310 CMR 15.401-15.405 THE FOLLOWING LOCAL UPGRAD00 BVW 01 �92- I C:) A� A '� . - 90" 89.00' APPROVALS ARE REQUESTED: d , I DOSING & STORAGE REQUIREMENTS ° �1.) A 5.0'VARIANCE (10'- 5') FOR THE SETBACK FROM THE FRONT PROPERTY LINE TO •i Standing Water 96" THE PROPOSED LEACHING FACILITY. BVW 2 - 50'WETLAND OFFSET I / DESIGN FLOW: 330 GPD , , � t • , I 8 8' r # a- 2. A 14.9'VARIANCE 20' -5.1 FOR THE SETBACK FROM THE EXISTING FOUNDATION { * •. C Medium Sand ( ) ( ) 97x6 O� DOSING REQUIRED: 8 CYCLES/DAY . ' , 2.5Y 6/6 TO THE PROPOSED LEACHING FACILITY. 96- 10.2' #225 / // 330 GPD/8 =42 GAUCYCLE �-- ,,�, • '• `~ _ •G (3.) A 50% REDUCTION IN THE REQUIRED LEACHING SUBSURFACE AREA DESIGN PROPOSED H-20 PUMP CHAMBER \ 1 2 U / / / +- - REQUIREMENTS. IGARAGE ON AND PUMP OFF FDISTANCE DLOATS BETWEEN PUMP\ EXISTING\ - U S G S LOCUS - Monitored a well for over 30 days and 120" 86.50' (4.) A 1.2'VARIANCE (10'-8.8') FOR THE SETBACK FROM THE EXISTING GARAGE SLAB \ BVW I 95 2 3-BEDROOM BVW 11 x2 DWELLING 42 GAUCYCLE - 250 GAL/FT - 0.17 FT/CYCLE TO THE PROPOSED SEPTIC TANK. �i 95 / 22. THE FOLLOWING LOCAL VARIANCES ARE REQUESTED FROM THE BARNSTABLE CODE PROPOSED BLOWER (LOCATION TO d 96 /� found the highest water level to be @ el. STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GAL. BOARD OF HEALTH REGULATIONS ARTICLE 1, SEC. 360-1: BE CONFIRMED BY HOMEOWNER) I / STORAGE PROVIDED ABOVE WORKING LEVEL: 832 GAL. SCALE: 1" = 1000' 90.78'. See below for monitoring well � � (1.) A 49.8'VARIANCE (100'- 50.2') FOR THE SETBACK FROM THE BVW TO THE 94x3 TOF=99.1' g6 data. PROPOSED LEACHING FACILITY. PROPOSED 3"MIN. VENT PIPE - - (LOCATION TO BE CONFIRMED PROPOSED _ ' MAP 209 RESERVED FOR LEGEND MONITORING (2.) A 58.8'VARIANCE (100'-41.2') FOR THE SETBACK FROM THE BVW TO THE d �I �� PROPOSED SEPTIC TANK. BY HOMEOWNER) o HAYBALES (TYP)� / , --- PARCEL 43 BOARD OF HEALTH USE WELL DATA (3.) A 56.0'VARIANCE (100'-44.0') FOR THE SETBACK FROM THE BVW TO THE LMr� 94 ENCLOSED PROPOSED PUMP CHAMBER. \ of PROPOSED H-20 18,680 S.F. ± o `O 1500-GAL. SEPTIC TANK PORCH 94 _ VW 10 (0.43 Ac) 50x0 EXISTING SPOTGRADE MAP 208 0 _ �0I WITH MicroFASTTM' / \ ELEV TOP OF WELL PIPE = 96.78' _ - - 50-- EXISTING CONTOUR It LO MODEL NUMBER0.5 - - - - - - - - - - - - - - - - PARCEL 102 o Cl? / `�' READING# 1 50 PR. SPOT GRADE N/F BOILES ro I \ PROPOSED 224 S.F. DECK / / \ O DEPTH OF WATER= 75" PR. CONTOUR O\ ` I LEACHING FIELD / ELEV WATER= 90.53' EXISTING DRAINAGE 92� ` DATE= - - - - - - - - - EXISTING WATER SERVICE LINE 0330-05 - L/ I /L EXISTING OVERHEAD UTILITIES I � - WETLAND LINE - EASEMENT(BK 315, PG 7) I REMOVE & REPLACE UNSUITABLE � � READING# 2 W W BVW 4 MATERIAL TO C-SOILS WITH CLEAN COARSE SAND -92- ! DEPTH OF WATER= 73" -W-W- PR. WATER SERVI�E LINE TREE LIME ELEV WATER= 90.70' GAS EXISTING GASLINE: 'ROPOSED 40 MIL IMPERV. BVW 9 -� DATE = 04-13-05 - - - TEST PIT LOCATIC,N APPROXIMATE OMEMBRANELINER- ^ - - - - - - - - - - - - - LOCATION OF BVW 5 000-W _. L - -O�` READING# 3 PR. 4" SOLID SCHEDULE 40 PVC PIPE DRAINAGE DITCH I *` � BVW 7 BVW 8 DEPTH OF WATER= 73" t EXISTING NOTE: ELEV WATER= 90.70' PR. 2" SOLID SCHEDULE 40 PVC PIPE DRAIN PIPE BVW 6 ENTIRE PROPERTY IS NOT LOCATED WITHIN A DEP DATE - 04-20-05 - --- - PR. 4" PERF. SCHEDULE 40 PVC PIPE APPROVED ZONE II AND IS NOT LOCATED WITHIN TOWN - - - - - - - - - - - - - - - - DESIGNATED ZONE OF CONTRIBUTION. READING# 4 -------- PR. 1-1/2" PERF. S;HEDULE 40 PVC PIPE DEPTH OF WATER= 72" SITE PLAN ELEV WATER= 90.78' 00 PR. 1500 GAL. H-20 SEPTIC TANK DATE= 05-04-05 WITH MICROFAST MAP 209 SCALE: 1" = 10' - - - - - - - - - - READING# 5 0 Q PR. 1000 GAL. H-26 PUMP CHAMBER PARCEL 047 N/F TOWN OF BARNSTABLE (5 DEPTH OF WATER= 73" 1 8-5-05 MCP JLC ADDED ALTERNATIVE SYSTEM PER BOH MA/N STREET- (4 ELEV DATE WATER= 90.70' 05 EXISTING LIGHT POST REV. DATE BY APP'D. DESCRIPTION DESCRIPTION HC GC 3 6) - °535p _ _ O EXISTING DRAIN MANHOLE PROPOSED SEPTIC SYSTEM UPGRADE s8p ( - - - - - - - - - - - - - - E CORNER OF S.T. (1) 14.7' 18.2' � Note: w 208.55' (8 7) Used 90.78'as elevation of ground water for design. ® EXISTING DRAIN CATCH BASIN PREPARED FOR: do #225 Sss°S°, CORNER OF S.T. (2) 10.2' 16.6' 2) o MAP209 634 ?°'F GC C BUOYANCY CALCULATIONS JOANENEFF MAP 208 Z o0 PARCEL 43 4 P.C. COVER IN (3) 21.6' 12.6, 1) I 225 MAIN STREET PARCEL 102 P.C. COVER OUT(4) 24.1 17.6 GARAGE #225 1500 H-20 SEPTIC TANK 1000 H-20 PUMP CHAMBER N/FBOILES °oo2"\14 EXISTING CENTERVILLE, MA 02632 ey S69 q LEACHING CORNER (5) 19.2' 23.5' 3-BEDROOM HIGH GROUNDWATER EL.= 90.78' I HIGH GROUNDWATER EL.= 90.78' NO 7 �3g9 DWELLING BOTTOM OF H-20TANK EL. =88.25' BOTTOM OF H-20 TANK EL. = 87.80' SCALE: 1 INCH = 10 FT. DATE: JUNE 16, 2005 Sr{OF RjA/5,72\x LEACHING CORNER (6) 20.4' 44.0' WATER DISPLACED = (90.78'-88.25')x 11.00'x 6.17' = 171.71 C.F. I WATER DISPLACED = (90.78' -87.80')x 9.00'x 5.25' = 140.81 C.F. o 5 10 20 ao FEET /pFOF MAP 209 WEIGHT OF DISPLACED WATER = 171.71 C.F. x 62.4 LB/C.F. = 10,715 LBS WEIGHT OF DISPLACED WATER= 140.81 C.F. x 62.4 LB/C.F. =8 786 LBS ��� Jo""L m O LEACHING CORNER 7 9.4' 35.3 o c"uRcl ILL /Tcy N/F DAVIS ( ) WEIGHT OF H-20 TANK=23,000 LBS. I WEIGHT OF H-20 TANK = 17,000 LBS. JR. � PREPARED BY: LEACHING CORNER (8) 12.8 16.9' WEIGHT OF SOIL= 11.00'x 6.17'x 3.00'= 203.61 C.F. x 110 LB/C.F. =22,397 LBS WEIGHT OF SOIL= 9.00'x 5.25'x 3.00' = 141.75 C.F. x 110 LB/C.F.= 15,592 LBS CIVIL JC ENGINEERING INC. WEIGHT OF H-20 TANK +WEIGHT OF SOIL =23,000 +22,397 =45,397 LBS WEIGHT OF H-20 TANK +WEIGHT OF SOIL = 17,000 + 15,592 =32,592 LBS No taa7 Ej,. 2854 CRANBERRY HIGHWAY INDEX PLAN- SWING TIES 32,592 LBS > 8,786 LBS (ACCEPTABLE)45,397 LBS > 10,715 LBS (ACCEPTABLE) EAST WAREHAM, MA 02538 �SCALE: 1" =60' SCALE: 1" = 20' 508.273.0377 Sheet:1 of 2 Drawn By: MCP Designed By:MCP Checked By:JLC JOB No.782 INSTALL 1-1/4" PVC TO HOUSE. JOINTS TO BE MADE WATERTIGHT. WIRE PUMP AND FLOATS TO SIMPLEX CONTROL PANEL No. 1-CC2 NEMA-1 MFG. HOOVER INSTRUMENTS. NEMA 4 JUNCTION BOX CORROSION RESISTANT HOISTING CABLE 7 x 19 STAINLESS STEEL & LIQUID-TIGHT CABLE CONNECTORS 1/8" DIA. / 1,760 LB. STRENGTH SUPPORTED CONNECTORS SUPPORTED BY 1-1/4" ��\ I I PVC CONDUIT, JOINTS TO BE MADE WATERTIGHT 2" BALL VALVE w/ UNIONS SCH. 80 PVC GEORGE FISHER CO. MODEL NO. 560 �� 3" r _ — 2" SCH. 40 TO LEACHING FACILITY o i MOLD PRECAST TANK WITH RUBBER N r M ALARM ON GASKET FOR INLET AND OUTLET `o co KNOCKOUTS. INSTALLER TO ALSO USE AP UMP ON o HYDRAULIC CEMENT AT JOINTS TO 7 Y20FF UMP oN ENSURE WATER TIGHTNESS.1 " SCH. 40 TEE w/ CLEAN-OUT CAP (2) WIDE ANGLE CONTROL FLOATS 1/4"WEEP HOLE IN DISCHARGE PIPE (BARNES 073618) U? (q 2".BALL CHECK VALVE SCH. 80 PVC 100 1: PUMP ON/OFF 120 ACTIVATION o C) P.S.I. FLOWMATIC MODEL No. 208S 2: ALARM ACTIVATION 1/4" WEEP HOLE IN DISCHARGE PIPE 2" SCH. 40 PVC DISCHARGE PIPE NOTE: TANK TO BE WATERTIGHT CERTIFIED BY MANUFACTURER (ACME BARNES SE411 PUMP, 0.40 H.P., 115 V, 1750 PRECAST OR APPROVED EQUAL). RPM, 2" DISCHARGE PASSING 1-1/2" SOLIDS (IMP. DIA. 4.75") OR EQUAL PROPOSED 1000 GALLON H-20 PUMP CHAMBER NOT TO SCALE 54" -25" Eu? MICROFAST NOTES -- N STAKED AND ENTRENCHED SILT FENCE STRAW BALE 5a1— (1) BLOWER MUST BE WITHIN 100 FEET(30.5m)OF FAST UNIT AND USE — 1" X 2" X 3' OAK A MAXIMUM OF 4 ELBOWS IN THE PIPING SYSTEM (@ 100 FT). FOR BEANPOLES, EROSION/SILTATION DISTANCES GREATER THAN 100 FT--CONSULT FACTORY. BLOWER Z 2 PER BALE FENCE TO BE BASE MUST BE LOCATED ABOVE NORMAL FLOOD LEVELS. U N O ® O BINDING WIRE INSTALLED (2) NFILTRATIONT TO BE OCAP WITH 6CATED v VENT GRAE FINISH TE W/ADE OTLEAST 7HIGHER OQANOID � ! OR TWINE SEDIMENT LADEN OPEN SURFACE AREA. SECURE WITH STAINLESS STEEL SCREWS. j RUNOFF FILTERED {{ {{ { OR: 500 GALLON RUNOFF f RUN VENT TO DESIRED LOCATION AND COVER OPENING WITH 3" MIN. LIQUID t { {{ - VENT GRATE W/AT LEAST 7.1 SQ. IN. OPEN SURFACE AREA. CAPACITY i L__1000 GALLbN MIN. LIQUID CAPACITY - - SECURE WITH STAINLESS STEEL SCREWS. VENT MUST NOT 60„ { ALLOW EXCESS MOISTURE BUILDUP OR BACK PRESSURE. SEPTIC TANK / SEE NOTE 3. ❑PENING FOR FAST (3) ALL APPURTENANCES TO FAST(e.g. SEPTIC TANK, PUMPOUTS, MODULE TO SIT IN TANK ETC.) MUST CONFORM TO ALL COUNTRY, STATE, PROVINCE, AND LOCAL CODES. (4) BLOWER CONTROL SYSTEM BY BIO-MICROBICS, INC. (5) COPYRIGHT(C)2001, BIO-MICROBICS, INC. (6) MUST INCREASE TANK SIZE BY 20% IF MINIMUM OF 10 INCHES IS USED BETWEEN THE UNIT AND THE BASE OF TANK. CONSULT FACTORY FOR APPROVAL. (7) THE PRIMARY COMPARTMENT MAY BE A SEPARATE TANK. 1 ,500 GALLON SEPTIC TANK W/ MICROFAST INSERT CROSS SECTION OF HAYBALE (8) FOUR LEG EXTENSIONS MAY BE USED TO STAND UNIT IN TANK ELIMINATING NEED FOR LID. NOT TO SCALE NOT TO SCALE (9) EITHER THE INFLUENT PIPE TEE SHALL BE FITTED WITH A PIPE CAP OR THE BAFFLE SEPARATING THE TWO ZONES SHALL BE EXTENDED ALL THE WAY TO THE TOP OF THE CONCRETE TANK. IF CHOOSING TO USE THE PIPE CAP, THEN THE BAFFLE SHALL BE AT LEAST 3" HIGHER THAN THE WATER LEVEL AS SHOWN ON THE DRAWING. 0.3' (BY BI❑-MICR❑BICS) BLOWER W/ HOOD (BY BI❑-MICR❑BICS) 1.3' (V O � I U? i7 REV. DATE BY APP'D. DESCRIPTION A A N � CONCRETE PROPOSED SEPTIC SYSTEM UPGRADE BASE CONCRETE PREPARED FOR: JOAN NEFF LOCATED AT III-111 ;111=111=1 I M I 1--III- 0.2' 5 MAIN STREET ELECTRICAL TYP 3 4' CENTERVILLE, MA 02632 C❑NDUIT (T❑ 2' MIN, AIR PIPING BLOWER CONTROL SYSTEM) 'CH OF SCALE: NOT TO SCALE DATE: AUGUST 8, 2005 CHURCH,LL PREPARED BY: JR. CIVIL JC ENGINEERING, INC. BLOWER HOUSING BASE DIMENSIONS 48 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 BLOWER DETAIL BLOWER HOUSING DIMENSIONS (SECTION A-A) _508.273.0377 NOT TO SCALE NOT TO SCALE NOT TO SCALE Sheet:2 of Drawn By: MCP Designed By:MCP Checked By:JLC JOB No.782 TOP OF FOUNDATION = 99.1' PROVIDE (H-20) CAST IRON MANHOLE 4" PVC VENT PIPE 3/4"TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 2" CAP GENERAL NOTES FRAME & COVER TO FINISHED 2"OF 1/8"TO 1/2" DOUBLE WASHED STONE 2" INSPECTION PORT TO GRADE ON ALL LATERALS 1- UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION GRADE OVER ALL COVERS (COVER METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. FINISH GRADE EMBOSSED WITH "SEWER") 18" 12" MIN. /36" MAX. TOP OF S.A.S. = 96.59' 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD FINISH GRADE @ FND. EL.= 96.3 ± OVER TANK EL.= 96.5' - 97.4' -- - 3"MIN. OF HEALTH AND THE DESIGN ENGINEER. TOP EL. 2" SCH. 40 3. 4"SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL 12"36"M' 95.42' TO LEACHING r- 3/8" PERFORATION TO BE PLACED AT THE FACILITY CONTINUOUS PITCH BACK TO TANK CROWN OF THE PIPE AT THE END OF BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. EXIST. Cl PIPE EACH LATERAL PRIOR TO THE ELBOW 4 - AN 2" SCH. 40 FORCE MAIN _ '• EA TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN - '• .- -- - ELEVATION - 96.59' FOR A DISTANCE OF 15'AROUND THE PERIMETER OF THE SAS. 4"SCHEDULE 40 PVC 3' 1-1/2" PERFORATED LATERAL BOTTOM OF TRENCH TO BE LEVEL EL. = 95.80' UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACED AT LEAST FIVE FEET FROM S.A.S. SLOPE 2�°min-� 6" 3" ' 2" MANIFOLD S = 0.50% 45° ELBOW SET LEVEL INV. ELEV. = 96.30' 12 3"DROP MIN. 9 ( ) AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. INV (out) 10„ ALARM ON INV (out) BACK TO FORCE MAIN FIELD PROFILE 5' MIN. 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. �95.52'*) a8 INV (O1 14" 93.67' NOT TO SCALE _ 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. LIQUID 93.75 PUMP ON N GROUND WATER ELEV.- 90.78 89.75' LEVEL +` o SET INVERT OF 4" PERFORATED 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO INV (in) 89 25' PUMP 6"CRUSHED STONE CONCRETE THRUST BLOCK SCH. 40 PVC VENT PIPES AT OR FINISH GRADE OVER LEACHING FIELD - 97.59' - 97.69' BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR 94.00 �� OVER MECHANICALLY ABOVE CROWN OF LATERAL FSLOPE @ 2% MIN. OVER SYSTEM INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING • -__. , _ .•- - _- - r. -_- _ _ COMPACTED BASE 3/8" PERFORATION AT 5 3/8" PERFORATION AT 7 APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 10.1'�I O'CLOCK (TYP.) O'CLOCK (TYP.) TOP OF S.A.S. = 96.59 12" MIN. 8. ELEVATIONS BASED ON ASSUMED DATUM OF 96.33'OBTAINED FROM TOP OF OUTLET TEE � A 36" MAX. CENTER BACK OF CATCH BASIN ON MAIN STREET AS SHOWN ON PLAN. o "APPROXIMATE ELEVATION. GAS BAFFLEV INVERT 2 (TYP.) (TYP.)1. PEASTONE 2"OF 1/8"TO 1/2" K 1-1/2" PVC 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION -" THROUGH DIG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE CONTRACTOR SHALL VERIFY. NOTE: EL.=95.80' =="• DOUBLE WASHED _--_---_ PERFORATED PIPE MOLD PRECAST TANK WITH RUBBER AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY 2"SOLID MANIFOLD 2 STONE DISCREPANCIES TO THE DESIGN ENGINEER. GASKET FOR INLET AND OUTLET SLOPE 0.50%BACK 2.5' i 6"EFFECTIVE LENGTH 12-2" WIDTH 6'-8" DEPTH 6'-2" KNOCKOUTS. INSTALLER TO ALSO TO FORCE MAIN ' + DEPTH ALL JOINTS WHERE PIPE ENTERS AND EXITS CONCRETE USE HYDRAULIC CEMENT AT JOINTS INVERT 3/4"TO 1-1/2" DOUBLE i1o. STRUCTURES SHALL BE MADE WATERTIGHT. TANK SHALL BE INSTALLED ON A LEVEL STABLE BASE TO ENSURE WATER TIGHTNESS. EL.=95.78' 2' �� �, 2.5' 2.5' WASHED STONE TO 2' 5' 2'� 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR 4" PVC VENT PIPE 1-1/2" LATERAL (TYP.) I 7 O'CLOCK 5 O'CLOCK CROWN OF PIPE 9' 5' MIN. ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH PROPOSED COMBINATION 1500 GALLON SEPTIC TANK / 38 DETERMINATION FROM APPROPRIATE AUTHORITY. A LATERAL CROSS-SECTION 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS 500 GALLON PUMP CHAMBER (H-20) PLAN VIEW FIELD END VIEW A-A GROUNDWATER ELEV.= 90.78' LOCATED UNDER PAVEMENT, DRIVES OR TRAVELED WAYS IN WHICH CASE NOT TO SCALE NOT TO SCALE NOT TO SCALE THEY SHALL BE WITHSTAND H-20 LOADING. -----EDGE 7 ' ! v '13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND PROPOSED 1-1/4" -E�FPAVEME DESIGN DATA ••:,•. , •'w.T". : � �• ©� ' TEST PIT DATA f FINES. MAIN STREETPERFORATED SCH. _�-NT f • ' + �_ St7 I AGENT: David W. Stanton, R.S. 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND Benchmark [EXISTING LIGHT 4pEXISTING CESS POOL TO BF POST TO BE 40 LATERAL NUMBER OF BEDROOMS (ASSESSORS) 3 �S .•• . Q► Pt Czrz •p UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF Center Back of CB EXISTING WATERLINE NUMBER OF BEDROOMS DESIGN 3 ••• . EVALUATOR: Michael Pimentel, E.I.T. PUMPED AND REMOVED ALONG Elev. =96.33' (1953 COUNTY LAYOUT- PUBLIC REMOVED AND PROPOSED 4" (DESIGN) LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN _ • LOCATION OF MONITORING WELL WITH SPOILED SOIL OFFSITiE ) TO BE REMOVED AND DESIGN FLOW 110 GAUDAY/BEDROOM •• • ' •• • ,• • •' • c DATE: January 6, 2005 COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN Assumed REPLACED "' • USED FOR GROUNDWATER AND DISPOSED OF IN (Assumed) PERFORATED REPLACED AS SHOWN '• • ` \ 4, . • ACCORDANCE WITH 310 CMR 15.255(3). PVC VENT PIPE �" TOTAL DESIGN FLOW 330 GAL/DAY , BM � � TEST PIT#: 1 I� DETERMINATION ACCORDANCE WITH TITLE V 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN DESIGN FLOW x 200 % = 660 GAL/DAY • j ! 111 ELEV TOP = 96.50' SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. EXIST. CB PROPOSED WATERLINE USE PROPOSED 1500 GALLON SEPTIC TANK ` • �_96x6 (MAINTAIN 10' MIN. _ ; • � ( ELEV WATER = 90.78' * 16. PROPOSED PROJECT IS LOCATED WITHIN: PROPOSED 4" SCH. 40 PVC VENT 25% REDUCTION (LOCAL UPGRADE APR. = 82.5 GAL/DAY ""'-- CF1WOOt� AWAY FROM SAS ) 1�. i (LOCATION TO BE CONFIRMED i ) REDUCED DESIGN FLOW= 247.5 GAL/DAY • _ Q -� " * PERC RATE _ <2 min/in ASSESSORS MAP 209 PARCEL 43 BY HOMEOWNER) - -X X - - X XI � � • • x /p 97xl EVGE OF p • . • • • w �- AVEMENT , • • ' 't OWNER OF RECORD: JOAN ANN CRIVELLI j> X xX-X- - -- p• • �.ti � DEPTH OF PERC = 72"- 90" s80 5'50„E cp aQ ' �(-X_X- s6x7 INSTALL 9' x 38 LEACHING FIELD • • • `'��✓� •�• �� ``' �'• �I ADDRESS: 3300 BINNACLE DRIVE, B-103 97x5 X X�� -X x X 97Jx0 • `•�' : • : t�l • TEXTURAL CLASS: 1 NAPLES, FL 34103 o`I't " � - X1-xX-X- , SIDEWALL CAPACITY • ! l • . • • �' A PROPOSED 2 SOLIU / 97x1 F • FEMA FLOOD ZONE C °Is � 90xn X xX- _ENCEUN 4. ' an err . . �/ 0 96.50 O g66 SCH.40 FORCE MAIN / JrX X-xX E NO SIDEWALL AREA CREDIT TAKEN . I y • • : • �li --- AS SHOWN ON COMMUNITY PANEL# 250001 0005 C 56� /� 38 0' - BOTTOM CAPACITY . . �` • �" 17. PLAN REFERENCE: _ ^� i /'''�� EXIST. 000�/ \ - _ t6 3 208 55' 96x7 (LENGTH x WIDTH) (0.74 GPD/SQ.FT.) = GAL/DAY ` I O ' ' FIII 1. PL. BK. 130, PG. 151 DMH �1�� ~ ._ S80 53'50" ( ) ( ) • • . • �, 66" 91.00' 18. DEED REFERENCE: D 38'x 9' 0.74 GAL/SQ.FT. = 253.08 GAUDAY -J ., �- D 3 -�.. 10.0' E •t •. • + • A Loamy Sand 1. DEED BK. 3454, PG. 65 ti / • ti ,�_ • I -94 TP 1 „ ti � �3: 10YR 3/2 68 90.83 --�_-_ S84°15'00" TOTALS: : ' i 1✓ 19 ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 3 `' EXISTING STEPS t • • * •r' " I I E = �� 96x5 = "�F.- ' - �. f • 11 20. PROPERTY LINE INFORMATION IS APPROXIMATE, ONLY. THIS PLAN IS TO BE USED ONLY 35.42' � - -� TOTAL LEACHING AREA 342.00 SQ.FT. n • • • • ' ?� TO BE REMOVED U Loamy Sand FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY AND REPLACED I /Eh�� TOTAL LEACHING CAPACITY 253.08 GAL/DAY I Q pc, : ,x; 72g 10YR 5/6 90.50' FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. I96x3 / r 1 w • , Perc21. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE g2_ I w - ui - 01 • ., - _ 90, 1-.- BVW89.00' APPROVALS ARE REQUESTED: � ` � = » � -� � - •-• DOS{NG & STORAGE REQUIREMENTS � �' � - k - 'IT LO (1.) A 5.0'VARIANCE (10'- 5') FOR THE SETBACK FROM THE FRONT PROPERTY LINE TO v \ DESIGN FLOW: 253.08 GPD �r - 96„ StandingWater 96"o 88 50' THE PROPOSED LEACHING FACILITY. BVW 2 ` C:) °D GARAGE - J 50'WETLAND OFFSET I / DOSING REQUIRED: 4 CYCLE/DAY -" �� -- • (2.) A 14.1'VARIANCE (20'-5.9') FOR THE SETBACK FROM FOUNDATION TO THE .: C Medium Sand 8.2' - 97x6 253.08 GPD/4 =63 GAUCYCLE ,✓ � -� • • PROPOSED LEACHING FACILITY. I • • #225 / / !' • ••� 2.5Y 6/6 (3.) A 25% REDUCTION IN THE REQUIRED LEACHING SUBSURFACE AREA DESIGN DISTANCE REQUIRED BETWEEN PUMP REQUIREMENTS. �IBVW ON AND PUMP OFF FLOATS: �(Ql:) A 1.8'VARIANCE (10'-8.2 ') FOR THE SETBACK FROM THE GARAGE SLAB 63 GAL/CYCLE = 125 GAL/FT = 0.50 FT/CYCLE 120" 86.50'IEXISTING FOUNDATION TO THE PROPOSED SEPTIC TANK/PUMP CHAMBER. EXISTING DRAINAGE BVW ` 3-BEDROOM 11 (USE 0.52'TO PROVIDE FOR 2 GALLONS OF BACKFLOW) 1 , ^G^ LOCUS_ (,5) A 9.9'VARIANCE (50' -40.1') FOR THE SETBACK FROM THE BVW TO THE PROPOSED u J J * Monitored a well for over 30 days and LEACHING FACILITY. EASEMENT(BK 315, PG 7) � \ 9•x x2 DWELLING found the highest water level to be @ el. d STORAGE REQUIRED ABOVE WORKING LEVEL: 247.5 GAL. (6.) A 1.9'VARIANCE (10'-8.1') FOR THE SETBACK FROM THE SUBSURFACE DRAIN TO I �96 STORAGE PROVIDED ABOVE WORKING LEVEL: 360 GAL. SCALE: 1" = 1000' data. See below for monitoring well THE PROPOSED LEACHING FACILITY. 94:. TOF=99.1' I22. THE FOLLOWING LOCAL VARIANCES ARE REQUESTED FROM THE BARNSTABLE CODE l MAP 209 MONITORING BOARD OF HEALTH REGULATIONS ARTICLE 1, SEC. 360-1: ;T M d PROPOSED HAYBAL A 59.9'VARIANCE (100' -40.1') FOR THE SETBACK FROM THE BVW TO THE INSTALL 1-1/4" PVC TO HOUSE. JOINTS TO BE MADE o (o LINE (TYP) _ �� \ ' , PARCEL 43 WELL DATA PROPOSED LEACHING FACILITY. C:) I v 4 ENCLOSED WATERTIGHT. WIRE PUMP AND FLOATS TO SIMPLEX CO �I� PROPOSED PORCH �94 VW 10 18,680 S.F. ± CONTROL PANEL No. 1-CC2 NEMA-1 MFG. HOOVER (2.) A 59.2'VARIANCE (100'-40.8') FOR THE SETBACK FROM THE BVW TO THE CO (0.43 Ac) INSTRUMENTS. ELEV TOP OF WELL PIPE - 96 78� PROPOSED SEPTIC TANK/ PUMP CHAMBER. o COMBINATION 1500 GAL. MAP 208 ��I SEPTIC TANK& 500 GAL. / NEMA 4 JUNCTION BOX CORROSION RESISTANT HOISTING CABLE 7 x 19 STAINLESS STEEL LEGEND PUMP CHAMBER (H-20) „ - - - - - - - - - - - - - - � & LIQUID-TIGHT CABLE CONNECTORS 1/8 DIA. / 1,760 LB. STRENGTH - 50-- EXISTING CONTOUR PARCEL 102 L READING# 1 N/F BOILES \ � � SUPPORTED CONNECTORS SUPPORTED BY 1-1/4" DEPTH OF WATER- 75" 0 PROPOSED SPOT I .9� I PROPOSED 38' x 9' DECK i PVC CONDUIT, JOINTS TO BE MADE WATERTIGHT 2" BALL VALVE w/ UNIONS SCH. 80 PVC ELEV WATER - 90.53' r� PROPOSED CONTOUR DE \ d I L�A�CHING FIELD / GEORGE FISHER CO. MODEL NO. 560 DATE - 03-30-05 WETLAND LINE _ _ _ _ _ _ _ _ _ _ _ _ _ _ EXISTING OVERHEAD UTILITIES REMOVE & REPLAC€_UNSUITABLE ' io 3" 2" SCH. 40 TO LEACHING FACILITY READING# 2 EXISTING WATER SERVICE LINE BVW 4 MATERIAL TO C-SOILS WITH o W W PROPOSED WATER SERVICE LINE CLEAN COARSE SAND DEPTH OF WATER= 73' -92- .•Q N C9 ALARM ON MOLD PRECAST TANK WITH RUBBER EXISTING GASLINE PROPOSED 4U MIL BVW 9 TREE LINE z - 7 N ELEV WATER = 90.70' a, GASKET FOR INLET AND OUTLET UMP ON N KNOCKOUTS. INSTALLER TO ALSO USE DATE = 04-13-05 TEST PIT LOCATION APPROXIMATE .,LOMEMBRANE LINER `t cfl - - - - - - - - - - - - - - '' PUMP HYDRAULIC CEMENT AT JOINTS TO ENSURE O O O PUMP CHAMBER LOCATION OF BVW 5 L - -0 r READING# 3 PROPOSED 1500/500 SEPTIC TANK/ DRAINAGE DITCH I � •► BVW$ OFF WATER TIGHTNESS. DEPTH OF WATER= 73" � (H-20) / EXISTING B 7 ELEV WATER= 90.70' \O NOTE: SCH. 40 TEE w/CLEAN-OUT CAP PROPOSED 4 SOLID SCHEDULE 40 PVC PIPE DRAIN PIPE BVW 6 ENTIRE PROPERTY IS NOT LOCATED WITHIN A DEP (2)WIDE ANGLE CONTROL FLOATS o N DATE - 04-20-05 PROPOSED 2" SOLID SCHEDULE 40 PVC PIPE APPROVED ZONE II AND IS NOT LOCATED WITHIN TOWN (BARNES 073618) 1p 2" BALL CHECK VALVE SCH. 80 PVC 100 - - - - -- - - - - PROPOSED 4" PERFORATED SCHEDULE 40 PVC PIPE DESIGNATED ZONE OF CONTRIBUTION. 1: PUMP ON/OFF 120 ACTIVATION o P.S.I. FLOWMATIC MODEL No. 208S READING# 4 PROPOSED 2" PERFORATED SCHEDULE 40 PVC PIPE 2: ALARM ACTIVATION 1/4"WEEP HOLE IN DISCHARGE PIPE DEPTH OF WATER= 72" SITE PLAN NOTE: TANK TO BE WATERTIGHT 2" SCH. 40 PVC DISCHARGE PIPE ELEV WATER = 90.78' EXISTING LIGHT POST ( DATE = 05-04-05 O EXISTING DRAIN MANHOLE CERTIFIED BY MANUFACTURER ACME BARNES SE51 PUMP, 0.50 H.P., 120 V, 1750 - - - - -- - - - - - - - - - MAP 209 SCALE: 1" = 10' PRECAST OR APPROVED EQUAL). RPM, 2" DISCHARGE PASSING 1-1/2"SOLIDS READING# 5 ® EXISTING DRAIN CATCH BASIN PARCEL 047 (IMP. DIA. 5.25")OR EQUAL N/F TOWN OF BARNSTABLE DEPTH OF WATER= 73" MAIN ST (4 ELEV WATER= 90.70' REV. DATE BY APP'D. DESCRIPTION BEET PROPOSED COMBINATION 1500 GALLON SEPTIC TANK / DATE = 05-11-05 S80°53,so„E 5) - - - - -- - - - - - - - - - PROPOSED SEPTIC SYSTEM UPGRADE w 208.55, (3 500 GALLON PUMP CHAMBER (H-20) Used 90.78'as elevation of ground water for design PREPARED FOR: #225 S6S°S� DESCRIPTION HC GIC GC O 2) 6) RESERVED FOR JOAN NEFF o MAP 209 6344, F SEPTIC COVER IN (1) 16.1' 14.6'00 HC #225 BUOYANCY CALCULATIONS BOARD OF HEALTH USE LOCATED AT MAP 208 o PARCEL 43 PARCEL 102 Z 1) EXISTING 225 MAIN STREET N/F BOILES SEPTIC COVER OUT(2) 13.5' 13.1' 1500/500 COMBINATION TANK(H-20) CENTERVILLE, MA 02632 °6020, 3-BEDROOM ey g69 9N LEACHING CORNER (3) 19.1' 12.3' DWELLING HIGH GROUNDWATER EL.= 90.78' SCALE: 1 INCH = 10 FT. DATE: JUNE 16, 2005 NORTysip`X 113 MAP 209 LEACHING CORNER (4) 23.6' 19.9' TOF=99.1' BOTTOM WATER DIOF H-20 SPLACEDgN(90.78'-89?5')x 12.17'x 6.6T = 124.20 C.F. �1SH°FA 0 5 10 zo ao FEET WEIGHT OF DISPLACED WATER = 124.20 C.F. x 62.4 LB/C.F. = 7,750 LBS G - FO/Tcy PARCEL DAVIS LEACHING CORNER (5) 25A' 49.8' � c JOHN iLL PREPARED BY: WEIGHT OF H-2C TANK= 18,000 LBS. JC ENGINEERING, INC. LEACHING CORNER (6) 20.9' 47.3' WEIGHT OF SOIL= 6.67'x 12.17'x 1.08' = 87.67 C.F. x 110 LB/C.F. =9,643 LBS CJML WEIGHT OF H-2C TANK+WEIGHT OF SOIL = 18,000 +9,643 = 27,643 LBS "° 807 2854 CRANBERRY HIGHWAY � �. LOCUS PLAN 27,643 LBS > 7,750 LBS (ACCEPTABLE) �� ` `' EAST WAREHAM MA 02538 SWING TIES1 SCALE: 1" =60' 508.273.0377 SCALE: 1" =20' Drawn By: MCP Designed By:MCP Checked By: JLC JOB No.782