Loading...
HomeMy WebLinkAbout0790 PHINNEY'S LANE - Health 790 PHINNEYS LN., CENTERVILLE -..A=251-109 No. 42101/3 ®RA ESSELTE 10% (a O O O O i T a� i a 51 107 Commonwealth of Massachusetts r� Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville ✓ Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Important:When A. Inspector Information filling out forms on the computer, Sean M. Jones use only the tab key to move your Name of Inspector cursor-do not S.M.Jones Title V Septic Inspection use the return Company Name key. 74 Beldan Lane VJQ Company Address Centerville Ma 02632 City/Town State Zip Code 774-248-4850 smjonestitle5@gmail.com, SI4522 sean@smjonestitle5.com License Number B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined that the system: 1. ® Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails 2/6/2021 Inspector's Signature Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 1 of 18 I Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. City/Town State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: The property located at 790 Phinneys Ln Centerville is served by a Title V septic system consisting of a 1500 gallon septic tank, distribution box and 4 Infiltrators. Although the system was found to be in proper working condition at the time of inspection this report does not guarantee future performance under similar or increased usage. 2) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass" section need to be replaced or repaired.The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s)are replaced ❑ Y ❑ N ❑ ND(Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND(Explain below): 3) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: t5insp.doc•rev.7/26/2018 Title 5 Official Inspection form:Subsurface Sewage Disposal System•Page 3 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc•rev.7/262018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form F Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Citylrown State Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than '/2 day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis and chain of custody must,be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the questions in Section CA. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well t5insp.doc•rev.7/2612 01 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Citylrown State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered "yes" to any question in Section C.5 the system is considered a significant threat, or answered"yes"to any question in Section CA above the large system has failed.The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate"yes" or"no"for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined?(if they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] l5insp.doc-rev.7262018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 6 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form �- Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. City/Town State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms (design): 3 Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 gpd Description: Number of current residents: 3 Does residence have a garbage grinder? ❑ Yes ® No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ❑ Yes ® No Seasonal use? ❑ Yes ® No Water meter readings, if available (last 2 years usage(gpd)): Detail: Sump pump? ❑ Yes ® No Last date of occupancy: current Date t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Water treatment unit present? ❑ Yes ❑ No If yes, discharges to: Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: Tank was pumped for inspection Was system pumped as part of the inspection? ® Yes ❑ No If yes, volume pumped: 1500 gallons How was quantity pumped determined? size of tank Reason for pumping: routine maintenance t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System-Page 8 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form � Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Citylrown State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system(yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner)and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed (if known)and source of information: system installed 11-24-1998 per town records Were sewage odors detected when arriving at the site? ❑ Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: 2 feet Material of construction: ❑ cast iron ®40 PVC ❑ other(explain): Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): Sewer line video inspected from tank,joints in good condition, no leakage, vented through roof. t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 9 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form t A Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 6. Septic Tank(locate on site plan): Depth below grade: 1.5 feet Material of construction: ® concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance?(attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1500 gallons Sludge depth: 5" Distance from top of sludge to bottom of outlet tee or baffle 3' Scum thickness 2" Distance from top of scum to top of outlet tee or baffle 7" Distance from bottom of scum to bottom of outlet tee or baffle 10" How were dimensions determined? Opened covers and took measurements Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tank was pumped for inspection and should be done again every 2 years for proper maintenance. Water level was even with outlet, tank was not leaking and was structurally sound. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form I" Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap(locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 18 i Commonwealth of Massachusetts Title 5 Official Inspection Form I. Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 8. Tight or Holding Tank(cont.) Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments (condition of alarm and float switches, etc.): "Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0" Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Distribution box was level and in good condition with no major rot. Water level was even with outlet invert with no signs of past backup. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form F Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No* Alarms in working order: ❑ Yes ❑ No" Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.): If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System(SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: ❑ leaching pits number: ® leaching chambers number: 4 Infiltrators ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp.doc-rev.7/26/2018 Title 6 Official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments -� 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is Centerville Ma 02632 2/6/2021 required for every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cant.) Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): s.a.s. consists of 4 Infiltrators in a 30'x10'x2'trench. Leaching facility was video inspected from d-box and was found dry with no signs of past overloading. 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth-top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 14 of 18 1011 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Citylrown State Zip Code Date of Inspection D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): f t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 15 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in the area below ❑ drawing attached separately Io 0 l �2 Yy 3 R3 VO B 3 Sv t5insp.doc-rev.7/26/2018 TRIe 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 16 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ❑ Check Slope ❑ Surface water ❑ Check cellar ❑ Shallow wells Estimated depth to high ground water: 121+ feet Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date ❑ Observed site (abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health-explain: ❑ Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: Groundwater was established by accessing town of Barnstable groundwater contour maps. Before filing this Inspection Report, please see Report Completeness Checklist on next page. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments M 790 Phinneys Lane Property Address Henry Hunt&Anna Meagher Hunt Owner Owner's Name information is required for every Centerville Ma 02632 2/6/2021 page. Cityrrown State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or checked ® C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4(Failure Criteria)and 6 (Checklist)completed ® D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 18 of 18 Commonwealth of Massachusetts a51 -10'7 �n Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Ln �a Property Address s Meagher Owner Owner's Name : information is required for Centerville Ma 02632 9-17-18 x> every page. City/Town State Zip Code Date of Inspection 3.: <:Is Cn Inspection results must be submitted on this form. Inspection forms may not be altered in any I�w' way. Please see completeness checklist at the end of the form. Important: A. Inspector Information c 2 When filling out p forms on the computer,use Douglas A Brown only the tab key Name of Inspector to move your Douglas A Brown Inc cursor-do not Company Name use the return key. . P.O.BOX 145 Company Address k Centerville Ma 02632 City/Town State Zip Code 508-420-4534 S14297 Telephone Number License Number B. Certification I certify that: 1 am a DEP approved system inspector in full compliance with Section 15.340 of Title 5(310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.After conducting this inspection I have determined that the system: 1. ® Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails 9-17-18 In ignature Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 18 ' Commonwealth of Massachusetts �n Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityrrown State Zip Code Date of Inspection C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: At time of inspection this system met all minimum passing requirements. The system is 20 yrs old but at time of inspection was functioning properly. This report can not predict the future performance under the same or increased usage. 2) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND) for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18 Commonwealth of Massachusetts �n Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityfrown State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): 3) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 3 of 18 i Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No"to each of the following for all inspections: Yes No ❑ ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool ❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than '/2 day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the questions in Section CA. Yes No ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 5 of 18 Commonwealth of Massachusetts �n Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. City/Town State Zip Code Date of Inspection C. Inspection Summary (cont.) If you have answered"yes"to any question in Section C.5 the system is considered a significant threat, or answered "yes"to any question in Section CA above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate"yes" or"no"for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? ❑ ® Have large volumes of water been introduced to the system recently or as part of this inspection? ® ❑ Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ❑ ® Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ❑ ® Determined in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 6 of 18 c Commonwealth of Massachusetts r= Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owners Name information is required for Centerville Ma 02632 9-17-18 every page. Cityrrown State Zip Code Date of Inspection D. System Information 1. Residential Flow Conditions: Number of bedrooms(design): 3 Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 330 Description: Number of current residents: 2 Does residence have a garbage grinder? ❑ Yes ® No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: Is laundry on a separate sewage system?(Include laundry system inspection ❑ Yes ® No information in this report.) Laundry system inspected? ❑ Yes ❑ No Seasonal use? ❑ Yes ® No Water meter readings, if available(last 2 years usage (gpd)): Detail: 2016--------309 2017-----—393 gpd Sump pump? ❑ Yes ® No Last date of occupancy: 9-2018 Date t5insp.doc•rev.7%26M18 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18 cam. Commonwealth of Massachusetts �n Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Citylrown State Zip Code Date of Inspection D. System Information (cont.) 2. Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Water treatment unit present? ❑ Yes ❑ No If yes, discharges to: Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: Was system pumped as part of the inspection? ❑ Yes ® No If yes, volume pumped: gallons How was quantity pumped determined? Reason for pumping: t5insp.doc•rev.7/2 612 01 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments v� 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityfrown State Zip Code Date of Inspection D. System Information (cont.) 4. Type of System: ® Septic tank, distribution box, soil absorption system ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner)and a copy of latest inspection of the I/A system by system operator under contract ❑ Tight tank. Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed (if known)and source of information: 1998 per as-built Were sewage odors detected when arriving at the site? ❑ Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: feet Material of construction: ❑ cast iron ❑ 40 PVC ❑ other(explain): Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 18 c Commonwealth of Massachusetts 91-1 Title 5 Official Inspection Form le Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 6. Septic Tank(locate on site plan): Depth below grade: 2.5 feet Material of construction: ® concrete metal fiberglasspolyethylene other(explain) ❑ ❑ 9 ❑ ❑ If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No Dimensions: 1500 Sludge depth: moderate to heavy Distance from top of sludge to bottom of outlet tee or baffle Scum thickness heavy Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle How were dimensions determined? scour pole Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): I recommend pumping at time of transfer and every 2-3 yrs there after for maintenance. t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 10 of 18 c Commonwealth of Massachusetts �n p Title 5 Official Inspection Form Subsurface Sewage Disposal System Form-Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 7. Grease Trap(locate on site plan): Depth below grade: feet Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Capacity: gallons Design Flow: gallons per day t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 18 f Commonwealth of Massachusetts �n Title 5 Official Inspection Form <lo Subsurface Sewage Disposal System Form - Not for Voluntary Assessments ........... . 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. CitylTown State Zip Code Date of Inspection D. System Information (cont.) 8. Tight or Holding Tank(cont.) Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes ❑ No Date of last pumping: Date Comments(condition of alarm and float switches, etc.): "Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box(if present must be opened) (locate on site plan): Depth of liquid level above outlet invert 0" Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): box was functioning properly at time of inspection. there was some corrosion typical for its age. New cover was put on. t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 12 of 18 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 10. Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No" Alarms in working order: ❑ Yes ❑ No" Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): " If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: There were no observation ports found Type: ❑ leaching pits number: ® leaching chambers number: 4 infiltrators ❑ leaching galleries number: ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/alternative system Type/name of technology: t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments u 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation, etc.): sas was not opened because there were no observation ports found. Exact level of ponding or staining could not be determined. 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc-rev.7/2 612 0 1 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 14 of 18 Commonwealth of Massachusetts �a Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. City/Town State Zip Code Date of Inspection D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: Dimensions Depth of solids Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18 c Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Cityrrown State Zip Code Date of Inspection D. System Information (cont.) 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ❑ hand-sketch in the area below ® drawing attached separately t5ins .doc•rev.7/26/2018 p Title 5 Official Inspection Form:Subsurface Sewage Disposal System Page 16 of 18 c Commonwealth of Massachusetts �p Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. Citylrown State Zip Code Date of Inspection D. System Information (cont.) 15. Site Exam: ® Check Slope ® Surface water ® Check cellar ® Shallow wells Estimated depth to high ground water: greater than 5feet Please indicate all methods used to determine the high ground water elevation: ® Obtained from system design plans on record If checked, date of design plan reviewed: 9-2018 Date ❑ Observed site (abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health -explain: ❑ Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: design plan from owner Before filing this inspection Report, please see Report Completeness Checklist on next page. t5insp.doc•rev.7/2 612 01 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18 Commonwealth of Massachusetts �n Title 5 Official Inspection Form Subsurface Sewage Disposal System Form -Not for Voluntary Assessments 790 Phinneys Ln Property Address Meagher Owner Owner's Name information is required for Centerville Ma 02632 9-17-18 every page. CityTTown State Zip Code Date of Inspection E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: ® A. Inspector Information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked ® C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4 (Failure Criteria) and 6 (Checklist) completed ® D. System Information: For 8: Tight/Holding Tank—Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 18 of 18 Assessing As-Built Cards Page 2 of 2 http://www.townofbamstable.us/Assessing/HMdisplay.asp?mappar=251109&seq=1 9/18/2018 Assessing As-Built Cards Page 1 of 2 1 V YY IV yr DtUU qa 1 MDL.G LOCATION 7QO 6�/�1/PE'�}/S/hi SEWAGE N VILLAGE Le&&Zz///% ASSESSOR'S MAP&LOT /� INSTALLER'S NAME&PHONE NO.�.r.L/�/�"/z v v B�ifG SEPTIC TANK CAPACITY /3ba Gad LEACHING FACILITY:(type)�,��!ti 6� S ��/� (size)Af�(7''A P NO.OF BEDROOMS 3 BUILDER OR OWNER 74, PERMIT DATE: I/1.2 V1 COMPLIANCE DATE: 4/-3. .5 Y Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility S Feet Private Water Supply Welt and Leaching Facility (If any wells exist on site or within 200 feet of leaching facility) ��� Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) Feet Furnished by 510' 00 So http://www.townofbamstable.us/Assessing/HMdisplay.asp?>nappar=251109&seq=1 9/18/2018 TOWN OF BARNSTABLE LOCATION SEWAGE # VII,LAGE Gc°1? /�//ale ASSESSOR'S MAP & LOT —�® INSTALLER'S NAME&PHONE NO. SEPTIC TANK CAPACITY LEACHING FACILITY: (type) Cg/ (size) ,k�3> f NO.OF BEDROOMS BUILDER OR OWNER PERMITDATE: N COMPLIANCE DATE: Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility S�" Feet Private Water Supply Well and Leaching Facility (If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300.feet of leaching facility) Feet Furnished by p � r o m A Q c G O w • n n �� �- � 4' No. Fee THE COMMONWEALT F MASSACHUSETTS Entered in computer: Yes PUBLIC HEALTH DIVISION -TOWN BARNSTABLE, MASSACHUSETTS Rppfication for Oftgozaf *pztem Cou5truction Vermtt Application for a Permit to Construct( )Repair( v4pgrade( )Abandon( ) U Complete System ❑Individual Components Location Address or Lot No. Owner's Name,A d ss and Tel.No. nip Assessor's Map/Parcel /°e 7 /1m 1 / Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No. �j> '7 Type of Building: Dwelling No.of Bedrooms 3 Lot Size sq.ft. Garbage Grinder(✓�0 Other Type of Building L° No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow gallons per day. Calculated daily flow ��� gallons. Plan Date Number of sheets Revision Date Title -T Size of Septic Tank Type of S.A.S. Description of Soil Nature of Repairs or Alterations(Answer when applicable) /7`le I_Z G._ Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued t ' d Health. Signed 1.7o Date Il 7nlQ19" Application Approved by Date Application Disapproved for the following reasons Permit No. Date Issued fY, No. Feed_ THE COMMONWEALT MASSACHUSETTS Entered in computer: Yes PUBLIC HEALTH DIVISION -TOWN BARNSTABLE, MASSACHUSETTS Z(pprccat%on for Migotar *pgtem Construction Permit Application for a Permit to Construct(_, )Repair( 1i)Upgrade( )Abandon( ) M Complete System ❑Individual Components Location Address or Lot No. 7f O #hvlee p/�' Owner's Name A d ss and Tel.No. Assessor's Map/Parcel !/� ,,''y'' �/y �l Installer's Name Address,and Tel.No. Designer's Name,Address and Tel.No. /rJ Type of Building: Dwelling No.of Bedrooms -3 Lot Size sq.ft. Garbage Grinder(� Other Type of Building eg P No.of Persons Showers( ) Cafeteria( ) k Other Fixtures Design Flow /l d gallons per day. Calculated daily flow 53e gallons. Plan Date Number of sheets Revision Date Title Size of Septic Tank 1 �9Q Type of S.A.S. Description of Soil Nature of Repairs or Alterations(Answer when applicable) �i�/i� 1 Date last inspected: Agreement: ' The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system --- in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi- cate of Compliance has been issued t i d Health. Signed Date Application Approved by Date Application Disapproved for the following reasons Permit No. 7 4f�" r Date I'ssued "'. . , THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE, MASSACHUSETTS Certificate of (Compliance THIS IS TO CE TIFY, that 'e O -site S wage Disposal System Constructed( )Repaired (�)Upgraded( ) Abandoned )by D D Gd /' ` at 7 ® / i'!e _s e eh 7,'-� -v/ c has been constructed in accordance with the provisions of Title 5 and the for Disposal System Construction Permit No. dated Installer Designer The issuance of this-permit shall not be construed as a guarantee that the system will function as designed. Date - ut C/ R Inspector No. � q` c.�J --------------------...�— /—���Fee � ` THE-COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION - BARNSTABLE, MASSACHUSETTS lwigPoml 6pgtem Construction permit Permission is hereby nted to ns ct( )Repair( )Upgrade( )Abandon( ) System located at �01��O�7 / `I $J''" and as described in the above Application for Disposal System Construction Permit.The applicant recognizes his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided: Construction must be completed within three years of the d of t ' ermit. Date: �/�+ �" Approve:. � � (/ ✓ w 10/9197 NOTICE: This Form Is To Be-Used For the Repair Of Failed Septic Systems Only: CERTIFICATION OF SKETCH AND APPLICATION FOR A DISPOSAL WORKS CONSTRUCTION PERMIT (WITHOUT ENGINEERED PLANS) gQr '/Z/0/ lereby certify that the application for disposal works construction permit signed by me dated /�/ZO��S` , concerning the property located at 2LP hWe !/7, 1'?0AVy111 meets all of the following criteria: X There are no wetlands located within 100 feet of the proposed leaching facility /There are no private wells within 150 feet of the proposed septic system Y There is no increase in flow and/or change in use proposed There are no variances requested or needed. /Ifthe proposed leaching facility will be located within 250 feet of any wetlands, the bottom of the proposed leaching facility will=be located less than fourteen (14) feet above the maximum adjusted groundwater table elevation. Please complete the following: A)Top of Ground Elevation (according to the Engineering Division G.I.S. map) B) Observed Groundwater Table Elevation(according to Health Division well map) SIGNED : DATE: LICENSED SEPTIC SYSTEM INSTALLER IN THE TOWN OF BARNSTABLE NUMBER (Attach a sketch plan of the proposed system.Also if the licensed installer posesses a certified plot plan, this plan should be submitted]. q:health folder.cart I r i tLd tP� use � o P s 0 a w srw ,w.c. i i I �ta i f yo' 34 39 00 I I I i i i� TOWN OF BARNSTABLE _ LOCATION 7�� ��J;Ofe yS 4, SEWAGE# VILLAGE ASSESSOR'S MAP & LOT_�5 INSTALLER'S NAME&PHONE NO. .L/,� ,l�•�,. r!o✓ ���-b'�%G SEPTIC TANK CAPACITY if LEACHING FACILITY:(type) G 4/41/i 5 ��/� (size) /O 3> A NO.OF BEDROOMS 3 I BUILDER OR OWNER j PERMTTDATE: COMPLIANCE DATE: f/- • c1 fl Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility S f Feet Private Water Supply Well and Leaching Facility (If any wells exist on site or within 200 feet of leaching facility) gL14 — Feet Edge of Wetland and Leaching Facility(If any wetlands exist -� within 300 feet of leaching facility) Feet Furnished by TOWN OF BARNSTABLE LOCATION I�� Pf-tOrKU] Y • SEWAGE # VILLAGE C-Qm � ASESSOR'S MAP & LOT INSTALLER'S NAME & PHONE NO SEPTIC TANK CAPACITY LEACHING FACILITY:(type) (size) NO. OF BEDROOMS- PRIVATE WELL OR PUBLIC WATER BUILDER OR OWNER DATE PERMIT ISSUED: , DATE COMPLIANCE ISSUED; VARIANCE GRANTED: Yes No . _ ���� , `�i�:� �� ` ,_Bey 9 V �"�_ � � � �-�� ... �.�` �, i �- 109 THE COMMONWEALTH OF MASSACHUSETTS BOAR® OF HEALTH TOWN OF BARNSTABLE Appliratinn for Disposal Works Tonotxnrtinn ramit Application is hereby made for a Permit to Construct ( ) or Repair (\__-j'an Individual Sewage Disposal System at: t QQ- Q 11 K 5. yG�VS.z: w ey!�1g�1�................................................... ---- ....................... ........... Loca on Address or Lot No �,..�-�`�-A. ................................... I `_ Owner ddress -------- ----------------- Installer Address d Type of Building Size Lot----------------------------Sq. feet Dwelling—No. of Bedrooms............................................Expansion Attic ( ) Garbage Grinder ( ) `4 Other—T e of Building No. of persons............................ Showers — Cafeteria Pa Other fixtures --------•--•--• -•-------•-•. w Design Flow........ .___....................gallons per person per day. Total daily flow------�,3_35-(-...................gallons. Ga Septic Tank—Liquid capacity............gallons Length................ Width................ Diameter................ Depth................ Disposal Trench—No..................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No------- Diameter....I--- ....... Depth below inlet......_t......... Total leaching area..................sq. ft. Z Other Distribution box ( ) Dosing tank ( ) aPercolation Test Results Performed by...............................................-------------------------- Date........................................ ,.a Test Pit No. 1----------------minutes per inch Depth of Test Pit.................... Depth to ground water-----------.......... __. f3:q Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ 1:+ •-••---------••-•----•--••--••----------------------------•-••••--------------•---------------------........................................................ 0 Description of Soil...............................................................................----------------------------------------•-------------------••-----•--••------.------... x w U Nature f Repairs or Alterations—Answer when applicabla_. .y4S .1�_� .....___.�_6.....�i0i i-----------. t, � .................................------..............-........---------••---- Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the system in operation until a Certificate of Com 1* has bee issue o of health. Signed `e_ -------...- Application Approved By --------- �J=�- ... -------- Da e Application Disapproved for the following reasons- ----------------------------................-------------------------------------------------------------------------------------- -------------------------------------------- ............................................................ --------------------- -------------.......................------------------................... .......... ---- --------------------------------------------------------- Da ---...---------....----....-- Permit No. — -------t �— _-------- Issued te � r No � -�= Fps.. ' ......... THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE Appliration for Disposal Works C>zonstrurtion Frrutit Application is hereby made for a Permit to Construct ( ) or Repair an Individual Sewage Disposal System at: .. -... o_.._p+�;w.r nr v ..�::�w .......................... ..........l.?...p,:-��.---,11 ..................................................... Location-Address or Lot No. 19 O ner . .A3dress�"'�zr�' v' r•;t kv, �J Installer �AddressW Type of Building Size Lot............................Sq. feet U Dwelling—No. of Bedrooms............................................Expansion Attic ( ) Garbage Grinder ( ) Other—T e of Building No. of persons____________________________ Showers — Cafeteria a' Other fixtures ............................ w Design Flow..... ....<�............................gallons per person per day. Total daily flow.... ?. ......................gallons. WSeptic Tank—Liquid-capacity............gallons Length................ Width................ Diameter-------......... Depth................ x Disposal Trench—No..................... Width.................... Total Length.................... Total leaching area....................sq. ft. Seepage Pit No....+................ Diameter.l.n.__.___.._. Depth below inlet_.! :(..._.._.__.. Total leaching area..................sq. ft. z Other Distribution box ( ) Dosing tank ( ) aPercolation Test Results Performed by.......................................................................... Date........................................ Test Pit No. I................minutes per inch Depth of Test Pit.................... Depth to ground water........................ (T.l Test Pit No. 2................minutes per inch Depth of Test Pit.................... Depth to ground water........................ _ P4 -------------------------------------------------------------------------------------------------•--......................................................... 0 Description of Soil...............................................................................--------------------------------------..........------------------------------------•... x U .............:...•-•-•-------•------------•-•--••....----....---...............---•---------•----••--••--------•------------•-------•-•-••-•--•----------•---•----------...--------...-------•--------•-- w U Nature off Reppair/s�o(�r( AAlterations—Answer when applicabl`�. ._C—,.A 4 _.......... ���_.._.,t�_...!.... . ._...... _ , .. ...'..,...'---••�,-•c-- ................................... Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of TITLE 5 of the State Environmental Code—The undersigned further agrees not to place the system in operation until a Certificate of Compliance has been issued by the board of health. v Signed ... .. ........ �.w� e`--------------- Application Approved B �... .. ... �p�..... Application Disapproved or the followingreason )) ate, .............................................................................................................................................................................................................. .............. ----------.-..... Date Permit No. ..------- - : %'� .............. Issued .-----.....riv---------------------------------------- THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH / TOWN OF BARNSTABLE Cex#tftra a of (foutylianre THIS IS TO ORTIEY That the Individual Sewage Disposal System constructed ( ) or Repaired Y ............ Installer atQ .... t ...(I................��' � ft ka ........ ...........�--�;r"x =' ....a.. .v y.c.:------.............------------.-...------------------------------ I has been installed in accordance wlth the provisions of TITLE 5 of The State Environmental Code as described in the application for Disposal Works Construction Permit No. ......... :.-........�,�........ dated ................................................ THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE SYSTEM WILL FUNCTION SATISFACTORY. DATE.... ............................................. .................... Inspector ............... ........ THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH TOWN OF BARNSTABLE /No....................:..y— �� FEE..��...... Disposal Works Tono#r iort rrtttit Permission is hereby granted :A `'� ' = = - a, - -.c_: -•'........................................•---...........-••...... to Construct ( ) or Repair ( an Individual Sewage Disposal System atNo.. ..............•- - r` 1F- 1. Y.K/ Street q as shown on the application for Disposal Works Construction Permit No? ........................ Dated.......................................... \\ : � �} U Board of Health DATE............... -------- FORM 36508 HOBBS 6 WARREN.INC..PUBLISHERS