HomeMy WebLinkAbout0749 SHOOTFLYING HILL RD - Health 740 Shootflying Hill Rd�
Centerville
A = 192 017
UPC 12534
No.2_153LOR
HASTINGS.MN
' No: Feed
THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: j
Yes
PUBLIC HEALTH DIVISION -TOWN OF BARNSTABLE., MASSACHUSETTS
ZippYication for Mfgpogat *p6tem Construction Permit
Application for a Permit to Construct( )Repair( )Upgrade( )Abandon( ) ❑Complete System O Individual Components
Location Address or Lot No. "t]y R S"d -F ti�_ l` Owner's ame,Address and Tel.No.
Assessor's Map/Parcel
Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No.
l_k<ek Coo,Asv
S� KLo s�- L9
Type of Building: _
Dwelling No.of Bedrooms Lot Size 25I 2 so.ft. Garbage Grinder
Other Type of Building No.of Persons Showers( ) Cafeteria( )
Other Fixtures
Design Flow - gallons per day. Calculated daily flow gallons.
Plan Date ? 16 Number of sheets Revision Date
Title
Size of Septic Tank 1 . -50 D Type of S.A.S. 2- _ vw C%- �c
Description of Soil
Nature of Repairs or Alterations(Answer when applicable)
Date last inspected:
Agreement:
The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
,1 in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi-
cate of Compliance has been issued by!�5._JJA�
of Healt .
Signed7 J Date IS @Z
Application Approved by Date
Application Disapproved for the following reasons
Permit No. ® Uy2 3 y2 Date Issued 0
1 Y
\ �j \ U
No a00 i� M tea `«•7 Fee
THE COMMONWEALTH OF MASSACHUSETTS Entered'in computer: ✓�
PUB IC HEALTH:DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS Yes
ZIpprication for Migoml bpztem Construction Permit
Application for a Permit to Construct( )Repair( )Upgrade( )Abandon( ) ❑Complete System ❑Individual Components
Location Address or Lot No. 1744 4l Sao Y)1%d4 \N' \ec Z Owner's DLarne,Address and Tel.No.
Assessor's Map/Parcel '
Q-z—
Installer's Name,Address,and Tel.No. Designer's Name,Address and Tel.No.
k elc.-..7 Cho '-
3IV, KZos�. L4
Type of Building:
Dwelling No.of Bedrooms Lot Size sq.ft. Garbage Grinder( �}�
Other Type of Building No.of Persons Showers( ) Cafeteria( )
Other Fixtures
Design Flow 3 d gallons per day. Calculated daily flow '3 gallons.
Plan Date 1'7 O-t- Number of.sheets 1 Revision Date
Title
Size of Septic Tank I , 1-7YO Type of S.A.S. 2
Description of Soil
` Nature of Repairs or Alterations(Answer when applicable)
Date last inspected-
Agreement:
The undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system
in accordance with the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certifi-
cate of Compliance has been issued by Board of Health. \
1 O.Y Signed �ar�•� Date d�� OZ
j Application Approved by / Date 0 �-
t Application Disapproved for the following reasons
Permit No.)(0? - 3 4/2 Date Issued o
1
THE COMMONWEALTH OF MASSACHUSETTS
BARNSTABLE, MASSACHUSETTS
Certificate of Compliance
THIS IS TO CERTIFY, that the On-site Sewage Disposal System Constructed( )Repaired( '✓)Upgraded( )
Abandoned( )by �-\ `e <C R CN V�_ (;:
at -7 u 0\ S oe _r Ntie� ky, \ has been constructed in accordance
with the provisions of Title 5 and the for Disposal System Construction Permit No.' 002-3 y2 dated b'U a
Installer Designer
The issuance of his pdrmit shall not be construed as a guarantee that the syst ill,ftt�ction as d Est d..�--
Date h Inspector h..
IV
---------------------------------------
No. (k)'—?t/;� Fee
THE COMMONWEALTH OF MASSACHUSETTS
PUBLIC HEALTH DIVISION - BARNSTABLE, MASSACHUSETTS
Mwigpogal *raem (Construction Permit
Permission is hereby granted to Construct( )Repair(e"U-,
pgrade( )Abandon( )
System located at �+ �� S�oa� q 1AAk Q
and as described in the above Application for Disposal System Construction Permit. The applicant recogni2es his/her duty to
comply with Title 5 and the following local provisions or special conditions.
Provided:Constru tion must be completed within three years of the.date of thi ermit.
Date: DD, Approved by
1
TOWN OF BARNSTABLE �
LOCATION T sJ1D0 J�//l�1 t1�j1� WAGE #
VILLAGE C rs i.,eilt We ASSESSOR'S MAP & LOT 012
INSTALLER'S NAME&PHONE NO. G/t
SEPTIC TANK CAPACITY
LEACHING FACILITY: (type)
�Qv • size) del d J�
NO. OF BEDROOMS 3 A
Y
BUILDER OR OWNER.
ZiPERMITDATE: bi COMPLIANCE DATE: 1 L�,�
Separation Distance Between the:
Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) Feet
Edge of Wetland and Leaching Facility(If any wetlands exist
within 300 feet of leaching facility) Feet
Furnished by
1 krl ,
TOP FNDN EL. 51.9' SYSTEM PROFILE TEST HOLE LOGS
ACCESS COVER TO WITHIN 6' OF FIN, GRADE (NOT TO SCALE)
ACCESS COVER (WATERTIGHT) TO ENGINEER. DARTER AND NYE
WITHIN 6' OF FIN. GRADE
BOARD OF HEALTH 0
�
MINIMUM ,75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 50 0' WITNESS I
EL. 49.6' RUN PIPE LEVEL 2' DOUBLE WASHED PEASTONE DATE: 1q/18f$4
\ TERN LAN
FOR FIRST 2 \ PERC, RATE = < 2 MIN/INCH
EXISTING.�2Q_ `� 3 MAX, LOCUS r
GALLON SEPTIC t4� 48.0` GLASS SOILS P# 3597TANK (H- 1OAS
3 47.4
l7
BAFFLE 47.57 ____ � E� Q Q CO C] Cl C7
C:l47.17' _ [� [�] Q ® [] [] C) (�] 4' AT SIDES ELEV,
6' CRUSHED STONE OR MECHANICAL m m I� 0 0 E l _D Cl C.] O� 50.2'
COMPACTION. (15.221 c2» �S 2' p ® C7 Cl L� Cl C7 L`l3 0 45,17'
DEPTH OF FLOW = 4 ( 3+% SLOPE) ( 2 % SLOPE) LOAM AND
TEE SIZES, 10, *CONFIRM OUTLET ELEVATION PRIOR TO 3/4" TO 1 1/2' DOUBLE WASHED STONE 2 0, SUBSOIL 48 2,
INLET DEPTH INSTALLATION OF ANY PORTION OF SYSTEM
OUTLET DEPTH = 14° LOCATION MAP NOT TO SCALE
FOUNDATION-- EXIST, SEPTIC TANK 15' D' BOX 13 LEACHING GRAVEL WITHFACILITY SAND ASSESSORS MAP 192 PARCEL 17
6.5' 4
6,97'
113,91' MED
SAND
\ 38.2'
12.0' 38.2'
NO WATER ENCOUNTERED
NOTES:
t 49.5
1 SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED > 1. DATUM IS APPROXIMATED FROM BARN. GIS MAPS
I f DESIGN FLOW 3 BEDROOMS ( 11Q_GPD) = 30 _GPD 2• MUNICIPAL WATER, IS EXISTING
USE A` 330 GPD DESIGN 'FLOW 3, MINIMUM PIPE PITCH -TO -BE 1/8' PER FOOT,
/ / I
SEPTIC TANK: 330 GPD ( 2 > = 660 4, DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-- 10
- 5. PIPE JOINTS TO BE MADE WATERTIGHT,
USE ' A 1500 GALLON SEPTIC TANK (RE-USE EXISTING) 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS.
1 LEACHINGi ENVIRONMENTAL CODE TITLE V.
2,(25 + 12.83) 2 (.74) = 112 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE
SIDES' 25 x 12.83 (.74) USED FOR LOT LINE STAKING. . n
BOTTOM• = - -23 7 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4 PVC,
472 I TOTALS 472 S.F. 349 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT
INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED
49.8 O USE (2) 500 GAL. LEACHING CHAMBERS WITH 4 FROM BOARD OF HEALTH.
+ 4 5 STONE ALL ARQUND 10, PUMP & REMOVE (OR FILL W/CLEAN SAND) EXISTING L, PIT
9.8
49
(a RETAINING co 1 ,. OAK X
N BENCH MARK - CORNER WALLS 5" J PANE E o 1 ",
- OF BRICK STEPS - �M LE 0 1 L G N D
EL, 51.5 X N I TI TL. Sl TE r_L_M
I 1 100.0 PROPOSED SPOT ELEVATION OF
H X #749 SHOOTF-LYING HILL RD .
20 10' 100x0 EXISTING SPOT ELEVATION IN THE TOWN OF:
i DECK X I 1~, 100 PROPOSED CONTOUR ( CENTERVILLE ) B A R N S TA B L E
1 918 i
L .- - - I 14" OA q 100 EXISTING CONTOUR
EXIST. 0 + 50.6 1 PREPARED FOR: R. SPINNEY
DWELLING + 9•6
TF = 51,9' 51 0 + 50.1 \ 49.9
f- 51.9 EXIST. ST x \ 1 20 0 20 40 60
51.0 (RE-USE) \
BOARD OF HEALTH
LOT 1 a;
25,270± SO. FT. 50.6 " + o �0 MA P �q ST 7, 2002
0.58t ACRES u, OAk` APPROVED DATE SCALE: DAT ��t�
W 50.0 ! cam' ARNE
ARNE H. `yG o H. T
1 OJALA OJALA
PA ED DRIVE F,p --�-5 -- -- s 1 off 508-362-4541 CIVIL '+ No. 263419
1-�jy4 T�j� �(` 1 fax 508 362-9880
Q No. 30792. ^sJ �FCISIEa��
I - 0 51. " 9fCISTER�QLAND S4Q
5011 fs G�� nr.•�
SHED so GRAVEL - -*`so. down cape engineering, inc. SroNAL
PARKING 0' 450,1
. I I CIVIL_ ENGINEERS
� sa0 LAND SURVEYORS
' ---X --,x`---= A-� sa.l W2 b _ ~ _ _ 25� 6 Z.--
-X-----X-----X- -. 4
Dz_26� 115.87' 939 vain st, yormouth, rya 02675 -- - _--�~-- A
I ARNE H. OJ.A LA, P.E., � L.S. DATE