Loading...
HomeMy WebLinkAbout0070 STAGE COACH ROAD - Health �i tage Coach Centerville �A= 173-026 UPC 12543 No. 53LOR • 41,TINC$ MN TOWN OF BARNSTABLE r� t��sa�-ry LOCATION �70 f7� e R 044 io SEWAGE# Z 613o`t7 G�VILLAGE eare,7, t-C ASSESSOR'S MAP&PARCEL INSTALLER'S NAME&PHONE NO. 77'1•727--37�� SEPTIC TANK CAPACITY 4500 GAL (=("T AR30 QL SE X LEACHING FACILITY.(type) 404 3(o NC_ (size) o NO.OF BEDROOMS OWNER <� � (1S l►.I "LLlc1'TY c� PERMIT DATE: COMPLIANCE DATE: Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility . 3 Feet Private Water Supply Well and Leaching Facility(If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) Feet FURNISHED BY Qi(ulxi j I � XT- �E � PARCEL #26 C ro�• � �, Area=92,521 SF± INS� I IL 23.01± 4 GD�fp3Y. �. oe (1 32)ARC 3GHC H-10 CHAMBERS CLEAN-OUTS ! CD V t i klo No. � ` ' v .✓ -' Fee THE COMMONWEALTR-OF MASSACHUSETTS Entered in computer: PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS Yes Applitation for bisposal 6pstem Construction Permit Application for a Permit to Construc a air a ) Abandon( ) El Complete System ❑Individual Components Location Address or Lot No. IO i1 Owner's Name,Address,and Tel.No.lYb S Si.yr.wo m4 O2v l Assessor's Map/Parcel I"!3 M 02,6 P g"r"s " �°�1"f' " '�118 771 72,31P Installer's Name,Address,and Tel.No. jr_s A esigner's Name,Address,,and Tel.No. 1S.3 Aq C,,,,541 I" NS� �. dl 2�ikci+t�s,ZMe. 3r8wj4yJ' b7'63(Ov 916 Type of Building: Dwelling No.of Bedrooms Lot Size 3�,;,30L sq.ft. Garbage Grinder( ) Other Type of Building F-2 M-F4?I No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow(min.required) 11,60 gpd Design flow provided gpd Plan Date 1/t 1-7 f 1-L p Number of sheets I Revision Date Title�T�p ca"L �ew Mtl h%J7 al-d M' Qt 14 n Size of Septic Tank ;S 6 p Type of S.A.S. je__- o�avi Description of Soil �a 1/5aa- 2. —IS-0 c> Nature of Repairs or Alterations(Answer when applicable) Date last inspected: Agreement: Tt undersigned agrees to ensure the construction and maintenance of the afore described on-site sewage disposal system in accordance w.!h the provisions of Title 5 of the Environmental Code and not to place the system in operation until a Certificate of Compliance has been issued by this Bo ealth. Signed Date Application Approved by Date-%-_ Application Disapproved by Date for the following reasons r Permit No. Date Issued Jx SN A 90 eN �^`x .y,;.• :cap t ,+M ...... e ^d ;A : No. r �� = / Fee + "' Entered in computer: TH E�OMM a_WEALTH`"Of_N�AS SAC HUSETTS Yes PUBLIC HEATH DIVISION -TOWN OF BARNSTABLE, MASSACHUSETTS ltlYlca -ion for Vspo8al 6pstem Construction.Permit Application for a Permit to Con's�ruc a ai gra ) Abandon( ) ❑Complete System ❑Individual Components .. Location Address or Lot No. `/O CeK VVFI t�$ Owner's Name,Address,and Tel.No.)Yb S.Sf. J�y.p",i'M4 02w l 02b42 Assessor's,Map/Parcel 113 M 026 P j g"r"a,it"W v j 12 Sag 77/ 7aaa 5 Installer's Name,Address,and Tel.No.'C6y,-)45 A _Os, Designe'r's Name,Address,and and Tel.No. /57T �4A1n S-/, r�%c ►�. Q(li,+� �/ISJuc1.TtS>Z"c• gfPw)4ey_ bV, ( *, Type of Building: .. Dwelling No.of Bedrooms �� Lot Size 30 s2,30(- sq.ft. Garbage Grinder( ) ++ Other Type of Building JF-2 M-Few+b No.of Persons Showers( ) Cafeteria( ) >, w Other Fixtures Design Flow(rin.required) gpd Design'ow provided a 3gq gpd Plan Date I-7/IZ r Number of sheets Revision Date Title P CO-, )ew A2:!� bi l ea'O J -4w /h - . y Size of Septic Tank Type of S.A.S. f`Avi 0a Description of�Soil ) q50 a a- xn Nature of Repairs or Alterations(Answer when applicable) r ' Date last inspected: 1 � t t Agreement: The undersigned agrees to ensure the construction and maintenance of theaf�fe described of-site sewage disposal system in Al, a N.accordance with the provisions of Title 5 of the Environmental Code and not to place e'system in op,'eraiion)uritil a Certificate of Compliance has been issued by this Bo ea h. Si ned • ,t. ,Date Application Approved by f r fr Dated Application Disappzoved by `� P ^.f' ? ,�' Date. '4" for the following reasons y , f Permit No. Date Issued _: =- = ------------- r -= THE COMMONWEALTH OF MASSACHUSETTS BARNSTABLE,MASSACHUSETTS ; '11 Certificate of Compliance l THIS IS TO CERTIFY,that the On-site Sewage Disposal system Constructed�4_), R paired( ) Upgraded Abandoned( )byZboOcS 6 7(my1 ) 1 tir / D1 s-'I-1- C.-n sty J-lUr� at 70 .aA 0702 has been constructed in accordance _ with the provisio f 'tle an then s o aEKSys�te Construction Permit No.90 f 3_G(-dated a l Installer �4h a RA l�� x "�1 .�- 6NSkesigner #bedrooms l Approved:design flow ,123 yy �� gpd The issuance of this permihall not be construed)as a guarantee-that the systemx i l,fne ion as designed. �' /� / f , _ , v l I PC', 1, r Date 6///i.� �i ,�4�f�L'. l. ��( ;�' P)t. ? Inspector- ✓` % il._ ) ' � d ROW E17 ---- ---- -- --------------- ------------------------- No. �O� - 04 Fee 1 S U THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION— BARNSTABLE,MASSACHUSETTS a �Disposai �&pstem Construction Permit Pe \sion is hereby granted to Con ) hce if /j7� Upgrade( ) Abandon( ) System located at '7d and as described in the above Application for Disposal System Construction Permit. The applicant recognized his/her duty to comply with Title 5 and the following local provisions or special conditions. Provided:Construction must be completed within three years of the date of this permit.a '7, c �, Date 0 ( r/ Approved by 07/09/2013 10:40AM 7744702270 DIG IT CONSTRUCTION PAGE 01 1 S Fawn of Barnstable Regulatory Service Thomas F.Geiler,Director 4 Public Health Division Thomas McKean,Director 200 Main Street, Hyannis,'TIA 02601 Office- 349-862-4644 Fax: 508-790-6304 Date., Sewageperwit� 'fib{{1 44JAssessoesmapmarcel 1_7 z(v Installer&Designer Certif cation Form Designer: dot,t G `` �Installer: Address. 'i, f'�- erect Address: on ( f }` ,� �as issued a permit to install a (date) (installer) septic system at 7(-) Q o c d based on a design drawn by ��YY (address) t�' 014,1l� �v�a�' S ,�ie�� dated /17 v I I®)(o-1 (designer) 1 certify that the septic system referenced above was installed substantially according to the design,which may include minor approved changes such as lateral relocation of the distribution box and/or septic tank. Stripout (if required) was inspected and the soils were found satisfactory. I certify that the septic system referenced above was installed with major changes (i.e. greater than l Q' lateral relocation of the SAS or any vertical relocation of any component of the septic system)but in accordance with Mate&Local Regulations. Plan revision or certified as-built by designer to follow..Stripout(if requi ceed and the soils were found ' factory.. �tN OF 1 0$ KEOH E. (last er's ature CIVIL [m 48725 (Designer's Signature) (Affi nx Desi. ere) PLEASE TURN Tt}BAI2NSTAB E P[T I,IG HLAET DMSION. CERTIFICATE .F CORP IS5UEI3 tiNTIJ BUT11 �Wluv AND AS- B T CAI23)AI2E RECE BY TDE BA YS AM YVEBLIC HE AILTH DIMION. TEL4NK YOU gAoM=f=mMemv=ccrtir=ion romt.d= NOTE: 1.)SEPTIC TANKS, DISTRIBUTION BOX, AND SAS CLEANOUTS HAVE CAST IRON COVERS AT GRADE. 252.94' PARCEL #2G Area=92,521 SF± 'E L=�5�. a ,,z ELEVATIONS ., r. Component Prop. As-Built dOO +I ST#I ^� u Inlet Invert 52.49 51.9± N Outlet Invert 52.24 5 1.7± 42. WI 5T#2 0'm � m" r3• , Inlet Invert 52.21 5 1.7± p 29.0_ Outlet Invert 5 1.9G 5 1.5± SAS 0 52.00 51.4± o Bottom 50.G7 50.1± D-DOX d Inlet Invert 51.93 5 1.5± O (1 32)ARC 3GHC Outlet Invert 5 1.7G 5 1.3 m H-10 CHAMBERS CLEAN-OUTS BENCHMARK: 'EL G4T 9^ " t. Top of Concrete Bound EL=72.2± (Assumed datum) / -FI CD V' LO 303.34, OF R4Ss�y ca KEIITH E. G O FERNANDES , T tpi \� SEWAGE DISPOSAL SYSTEM ASBUILT IVIL W, 1de.48725 487T � AT /3TEa�'® 70 STAGE COACH ROAD, CENTERVILLE, MA SS�ONAL ' ( Q� PREPARED FOR Off° BARN5TABLE HOU5ING AUTHORITY C� 0 GO 120 180 SCALE I"=GO' JUNE 2G, 2013 J Drawn by: KEF JMO-451 5 G:\ANobs\Barnstable Housing\Barnstable Hou5mg45 15 -5ta6jecoach\201 2 CONSTRUCTION PHA55A5-built\45 15-SEPTIC-ASBUILT.dwcg J.M. O'REILLY & ASSOCIATES, INC. 1573 Main Street, P.O. Box 1773 Professional Engineering &Surveying Services Brewster, MA 02631 (508)896-6601 t � Town ,of Barnstable OFFICE OF TOWN ATTORNEY OFZME tp� Barnstable c 367 Main Street � Hyannis MA 02601-3907 ;nmedca Y * BARNSTABLE, yQ MASS. vp i639. RUT A own Attorney Tel.#:,-M"62-4620 T. DAVID OUGHTON, 1s`Assistant Town Attorney Fax#: 508-862-4724 CHARLES S. McLAUGHLIN, Jr.,Assistant Town Attorney CLAIRE R. GRIFFEN, Paralegal/Legal Assistant PAMELA D. GORDON, Legal Clerk Inter-office Memorandum To: Thomas McKean, Director, Health Division From: Ruth J. Weil, Town Attorney [ ] Date: January 9, 2013 Subject: BHA - Stage Coach Road, Centerville Project -- Opinion Our File Ref: 2009-0288 I have been asked whether the Comprehensive Permit(Appeal No. 2009-069)that granted the Barnstable Housing Authority (BHA) permission to construct twelve (12) affordable rental units with a total of eighteen (18) bedrooms, establishes a building lot under the provisions of§360-45, the Board of Health regulation for the protection of estuaries. As you are aware, §360-45B. states in pertinent part: B. Restrictions. No permit for the construction of an individual sewage disposal system on any building lot shall be granted within the watersheds for the estuaries that have been identified as requiring a reduction in the current TMDL of nitrate-nitrogen as identified by the map entitled "Massachusetts Estuary Project, Zones of Contribution to Saltwater Estuaries, Town of Barnstable, March 10, 2008," unless the following standards are met: (1) The maximum allowable discharge of sanitary sewage, based on the sewage design flow criteria listed in 310 CMR 15.203, Title 5, of the [2009-0288\tommckeanmemo-reopinion\010913] 1 State Environmental Code, shall not exceed 440 gallons per 40,000 square feet of lot area, with the following exceptions: (a) For approved building lots on which no building currently. exists and that are less than 30,000 square feet in area,the maximum allowable sewage discharge shall be 330 gallons. (b) For parcels with existing buildings, the maximum allowable flow shall be either 440 gallons per 40,000 square feet, except as described in Subsection B(1)(a) above or whatever is currently permitted, whichever is greater. In its decision granting a comprehensive permit to the BHA, the Barnstable Zoning Board of Appeals (Board) described the building lot, for which the 18-bedroom development was permitted, as a 6.94-acres site comprised of two parcels. (See copy of the comprehensive permit attached hereto for your reference). Additionally, the Board required that before the issuance of any building permit for the development, that a conservation restriction be placed on approximately 4.9 acres of the building lot, to be dedicated to natural resource protection and open space. This requirement permanently dedicates 70% of the building lot to open space and otherwise limits its use to passive recreation. Under the totality of circumstances presented herein,�it_is-.myzopinion that for the purposes §360-45B,the comprehensive permit established a building lot comprised of 6.94 acres. Additionally, addressing another concern you expressed, no portion of this 6.94 acres building lot could be utilized as nitrogen credit land by another development as part of a state or locally approved Facility Aggregation Plan or Community Aggregation Plan. Finally, this opinion is based upon the terms of the comprehensive permit issued by the Board of Appeals to the BHA under Appeal No. 2009-069. If any modification of said comprehensive permit is sought in the future, continued compliance with the provisions of§360-45B would have to be analyzed. [2009-0288\tommckeanmemo-reopinion\0109131 2 07/09/2013 10:40AM 7744702270 DIG IT CONSTRUCTION PAGE 01 Town. of Barnstable Regulatory Services Thomas F.Geiler,Director Public Health Division s Thomas McKean,Director 200 Main Street, Hyannis,NIA 02601 Office: 548-862-4644 Fax: 5M79"304 Date: 13 Sewage Permit# d I{ q[Assessor's Map/Parcel 6 Installer&Designer Certification Form Designer, -�,��� y G Installer: ( fit. . �r,Y �,G...L Address: 15 73 y vv\(\ s gi'k- Address: 12z� On ( f r1L ? _ s issued ( a permit to instal!a (date) (installer) n I septic system at /0 S��1 i? �C h K c)C.4d based on a design drawn by (address) qSi coctc�S �� dated f�/1Z P �tS c��lr� I'lG 2— (designer) u I certify that the septic system referenced above was installed substantially according to the design,which may include minor approved changes such as lateral relocation of the distribution box and/or septic tank. Stripout (if required) was inspected and the soils were found satisfactory. I certify that the septic system referenced above was installed with major changes (i.e. greater than 10' lateral relocation of the SAS or any vertical relocation of any component of the septic system)bat in accordance with State&Local Regulations. Plan revision or certified as-built by designer to follow..Stripout(if required)W ' ected and the soils were found sfactory. cH of* E. DES ., (inst er's ature) CIVIL y No.41721 (Designer's Signature) (Affix Icsl ere) PLEASE N=—E TO BARNSTABLE PUBLIC HEALTH DIVISION. CERTIRICATE OF COIV WILL NOT BE IssuFD u.Nj I BOTH 1`lFl�S vOI2NI AND AS- B T CARD ARE RECE D BY THE BA STABLE PUBLIC HEALTH DIMION. 'I'F}tANK YOU. q:rnfrim fmmsWemgne=crtif=ion fom+.dw 7 NOTE: 1 .)SEPTIC TANKS, DISTRIBUTION BOX, AND SAS CLEANOUTS HAVE CAST IRON COVERS AT GRADE. 52.341 I PARCEL #2G �1 CO Area=92,52 1 5F± Bi #1 _TOFF ELEVATIONS Component Prop. As-Built ,17�—.=;. ST#I .. N I(� Inlet Invert 52.49 5 I.9± Outlet Invert 52.24 5 1.7± II Inlet Invert 52.21 5 1 .7± 29.0'± Outlet Invert 5I .9G 5I .5± SAS �i ti Top 52.00 5 1 .4± oe Bottom 50.G7 50.1 ± —BOXCr Inlet Invert 51 .93 5 1 .5 (132)ARC 3GHC ± O H-10 Outlet Invert 5 1 .7G 5 1 .3± CHAMBERS CLEAN-OUTS BENCHMARK: ft 049�+ Top of Concrete Bound EL=72.2± (Assumed datum) / +1 LO OF 303.341 i�ss c� KEITH E. ycN Q FERNANDES CIVIL -4- o Na 48725 �j ,� SEWAGE D15P05AL 5Y5TEM A55UILT AT ss�ONAL �- 70 STAGE COACH ROAD, CENTERVI LLE, MA 0 PREPARED FOR O 6 BARNSTABLE HOUSING AUTHORITY v 0 GO 120 180 SCALE I "=GO' JUNE 2G, 2013 Drawn by: KEP JMO-45 15 GAAAJ0b5\Barn5table Housing\Barnstable Hou5mcg45 15 -Sta6jecoach\201 2 CONSTRUCTION PHA5E\A5-built\451 5-SEPTIC-ASBUILT.dwg J.M. O'REILLY & ASSOCIATES, INC. 1573 Main Street, P.O. Box 1773 Professional Engineering & Surveying Services Brewster, MA 02631 (508)896-6601 f J.M. O'Reilly & Associates, Inc. LETTER OF Engineering& Land Surveying Services 1573 Main Street,2nd Floor,P.O.Box 1773 TRANSMITTAL Brewster,MA 02631 (508)896-6601 Fax(508)896-6602 TO: DATE: JOB NUMBER: Town of Barnstable 07/10/2013 4515A Public Health Division 200 Main Street REGARDING: Hyannis, MA 02601 70 Stage Coach Road Shipping Method: Centerville, MA Regular Mail �✓ Federal Express ❑ Certified Mail ❑ UPS ❑ Priority Mail Pick Up El Express Mail ❑ Hand Deliver COPIES DATE DESCRIPTION 1 7/9/13 Completed Installer& Designer Certification Form 1 6/26/13 Original Stamped Sewage Disposal System As-Built ` 7 ? O ZE For review and comment: For approval: As Requested: For your use:aW bX REMARKS: V) 75 I _;. cc:John M. O'Reilly, P.E., P.L.S. Dig It Construction Tim.Sawyer From: Emily O'Reilly/KEF If enclosures are not as noted,kindly notify us at once Op THE A BARNSPABLE. MASS. 039. rE0 MAC► Town of Barnstable Zoning Board of Appeals M.G.L-Chapter 4oB Comprehensive Permit Decision and Notice Barnstable Housing Authority Stage Coach Residences Comprehensive Permit No. 2oog-o6g Applicant: Barnstable Housing Authority Property Address: 70 Stage Coach Road and 151 Oak Street,Centerville,MA Assessor's Map/Parcel: Map i73,Parcels 026 and 0i4-00i Zoning: Residence C Zoning District and AP and RPOD Overlay Districts Permit Granted: Development of 12 units of affordable housing on 6.94-acres located at 70 Stage Coach Road and 151 Oak Street,Centerville,MA. Six of the units are to be one-bedroom flat style units and six are two-bedroom townhouse units. All of the units are to be rented as individual and family housing to individuals and households with an income level not to exceed 6o%of the area median income. Background Information: The Applicant: The Applicant is the Barnstable Housing Authority,a public agency created in i948 in accordance with Housing Authority Law of the Commonwealth of Massachusetts Chapter i21B. It is a municipal authority having an address of i46 South Street, Hyannis,MA 026ol. Ms.Sandra Perry is the Executive Director. The Locus: The locus is a 6.94-acre site composed of two parcels shown on Assessor's Map i73 as Parcels 026 and 014-001. The parcels are addressed 70 Stage Coach Road and 151 Oak Street in Centerville,MA. The northerly portion of the locus contains an abandoned cranberry bog and a vacant single-family dwelling. The dwelling is to be removed. The southern portion is an undeveloped treed lot that is access from Stage Coach Road. The proposed development of the locus is to be clustered on the southern portion. The northern and southern sections of the locus are separated by intervening wetland identified as a"Deep Marsh". Most of the locus is within an identified Priority Habitat or Estimated Habitat for endangered species as mapped by Massachusetts Natural Heritage&Endangered Species Program. It is within the Board of Health Zone of Contribution to Saltwater Estuaries. The locus is within a Residential C Zoning District and a Resource Protection Overlay District(RPOD). Applicant's Proposals: The Applicant proposes the development of"Stage Coach Residence",as an affordable housing development Of iz rental units(6 one-bedroom and 6 two-bedroom)in three buildings to be built on the property. Each building is to contain 2'townhouse units'(two-level,two-bedroom unit)and z`flat units'(one-level,one- bedroom unit). The townhouse units are i,024 sq.ft.and the flat units are 711 sq.ft.when on the first floor and 788 sq.ft.when on the second floor. Each unit includes a private rear deck and a covered entry or covered front entry. All units are to be affordable,rented to households or individuals at or below the 6o%income level for the Barnstable Metropolitan Statistical Area(MSA). The one-bedrooms are to be rented at$727.00 to$873.00 per month and the two-bedrooms at$872.00 to$1,047.00 per month. The buildings are clustered on the southern most 2.1 acres of the site,accessed from Stage Coach Road. The buildings are arranged around a center court area that is used for parking and a small green. Ten percent(io%) of the 21 acre development site is to be preserved and maintained as open space. The remaining 4.8-acres (70%)of the site are to be restricted in perpetuity as open space by means of a conservation restriction. On-site parking is provided for 24 vehicles. Development includes utility services and public water and related site improvements,drainage,lighting and landscaping. A shared on-site Title 5 wastewater disposal system that complies with all requirements of the Town's Board of Health is planned. No development or site disturbance is to take place within the jurisdictional boundaries of any wetlands. All drainage is to be contained on site and either channeled into dry wells or directed into a storm water management basin using best management practices to recharge the site runoff. Procedural History Project Development: In August of 2009,the Housing Authority made application to Massachusetts Housing Partnership(MHP)for a Project Eligibility letter for the Stage Coach Residences. The application was submitted under the Neighborhood Rental Initiative Program for funding of the development. On October 21,2009,Massachusetts Housing Partnership issued a Project Eligibility letter. Comprehensive Permit Application: On November 3, 2009,the Applicant filed an application for a Comprehensive Permit to develop the Stage Coach Residences. The application was filed at the Barnstable Town Clerk's Office and at the Zoning Board of Appeals Office. On November 4,2009, project notification and review request letters were sent from the Board's Office to other local boards,agencies and officials in accordance with CMR 760,Section 56.05(3)• A public hearing before the Zoning Board of Appeals was duly advertised in the Barnstable Patriot on November 13,2009 and November 20,2009 and notices were sent to all abutters in accordance with MGL Chapter 4oA. The hearing was opened December 2,2009 and continued to December 30,2009. The public hearing closed on December 3o`h and the Board continued the application to January 13,2010 to render a decision. At that meeting,the Board found to grant the comprehensive permits subject to conditions. Board Members deciding this appeal were,William H. Newton, Michael P. Hersey,Craig G. Larson,George T.Zevitas and Vice Chair,James F. McGillen who was Acting Chair during all proceedings. List of Materials Submitted: The following materials have been submitted to the file: 1. Application for a Comprehensive Permit time stamped November 3,2009 with the following attachments: • Attachment A— Documenting the Applicant as a Public Agency • Attachment B—A Copy of the Project Eligibility Letter • Attachment C—Documents on the Applicant's Ownership of the Property • Attachment D—Copy of Assessor's Map for Property and Abutters 2 • Attachment F-Project Description and Narrative • Attachment G—Project Site and Architectural Plans • Attachment H-Pro-Forma Analysis • Attachment I—List of Public Agencies for Review and Approval: • Attachment J—List of Requested Exceptions • Attachment 1—Developers' Profile • Attachment L—A Copy of the Town of Barnstable's September i6,2009 letter responding to Massachusetts Housing on the Project Eligibility Application z. November 4,2oo9 e-mail correspondence from Attorney Andrew Singer. 3. Project notification and review request letters dated November 4,2009 to: • Town Council President, Frederick Chirigotis,Town Manager,John C. Klimm,Town Attorney, Ruth J. Weil,Town Tax Collector, Maureen Niemi,and Building Commissioner,Thomas Perry, • Department of Public Works,Mark S. Ells, Director and Robert Burgmann,Town Engineer,and the Department of Health,Safety and Environmental Services,Thomas F.Geiler, Director, • Barnstable Housing Committee, Michael Schultz,Chair, Barnstable Planning Board, Felicia Penn,Chair, and Barnstable Historical Commission, Barbara Flinn,Chair. Growth Management Department,Jo Anne Miller Buntich, Interim Director and Arden Cadrin,Affordable Housing Coordinator also copied: Barnstable Conservation Commission, Dennis Houle,Chair,and Conservation Administrator, Robert Gatewood, Barnstable Board of Health, Dr.Wayne Miller, MD,Chair,and Health Director,Thomas McKean • Barnstable Police'Department, Paul MacDonald,Chief, Barnstable Public Schools, Dr. Patricia Grenier, Superintendent,Centerville/Osterville/Marstons Mills Fire Department Fire Chief John Farrington and the Cape Cod Commission, Paul Niedzwiecki, Executive Director 4. Abutter and notification information dated November 5,2009. 5. November 9,20o9 Abutter List Certification for Town of Barnstable Assessing Office. 6. November i8,2009 comment letter form Cape Cod Commission. 7. November 23, 2009 Supplemental Information Submitted by Attorney Andrew Singer and consisting of three attachments. 8. Copy of Chapter 59,of the Code of the Town of Barnstable-Comprehensive Occupancy. 9. Copy of Chapter iiz,Article i off the Code of the Town of Barnstable—Protection of Historic Properties. io. Copy of e-mail correspondence from Thomas McKean, Barnstable Director of Health dated November,24, 2009 1i. Letter from Martin MacNeely, Fire prevention Officer,Centerville-Osterville-Marstons Mills Fire Department dated November 23,2009omprehensive Occupancy. 12. Copy of e-mail correspondence from Robert Burgmann, Barnstable Town Engineer, Department of Public Works,dated November 23,2009. i3. Memorandum from Rob Gatewood,Conservation Agent received November i3,2009 14. Copy of the November 23,20o9,Town of Barnstable,Growth Management Department,Staff Report. 15. November 24,2oo9 correspondence form Felicia Penn,Chair, Barnstable Planning Board. 16. November 24,2009 correspondence form Arden R.Cadrin,Special Project Coordinator,Affordable Housing. i7. Correspondence from Michael Schulz dated November i9,2009(received November 24,2009). 3 i8. Copy of"The Basics of Chapter 4oB"submitted by Mr. Edward H.Marchant,independent consultant to the Board as submitted December 2,2009. 19. Copy of Accident Report for the area from of-01-2007 to 07-22-20o9 as submitted by Jayne Pierce December 2,2009. 20. Copy of area map as submitted by Attorney Paul Revere on December 2,2009. 21. Pictures showing street flooding on Stage Coach Drive as submitted December 2,2009. 22. Copy of a November 27,2o09 Cape Cod Times Article"Endangered turtle slows affordable housing project"as submitted on December 2,2009. 23. Copy of a December 7,2009 letter from the Board to Ruth J.Weil,Town Attorney requesting input on Stage Coach Road access issue. 24. A December 23,2009 Memorandum from Town Attorney, Ruth J.Weil in response to the Boards' December 7, 20og request. 25. Copy of Zoning Board of Appeals of Groton vs. Housing Appeals Committee—45i Mass 35 submitted December 30,2009. 26. Supplemental information submitted by the Applicant dated December 30,2009. 27. Copy of correspondence submitted January 2,2010 after the close of the public hearing. Two of which are dated July 9,20o9 and December 2,2009. Findings of Fact on Consistency with Local Needs: Motion: On January i3,2010,a motion was duly made and seconded to make the following findings of fact as it relates to the proposal which is to be consistent with local needs: 1. The Applicant is the Barnstable Housing Authority,a public agency,seeking a comprehensive permit under the General Laws of the Commonwealth,Chapter 4oB"Affordable Housing"and the Code of Massachusetts Regulations 760,Section 56. The permit is for the development of i2 multi-family units on 6.94-acres located in Centerville,MA. 2. The locus for the proposed development is owned by the Applicant. It consists of two parcels shown on Assessors Map 173 as Parcels 026 and 014-00i,commonly addressed as 151 Oak Street and 70 Stage Coach Road,Centerville, MA. Parcel 026 consists of approximately 2.12 acres. Parcel 014-00i consists of approximately 4.82 acres. 3. The northerly portion of the locus,151 Oak Street,is improved with a single-family dwelling,shed,and septic system. The dwelling,which is currently unoccupied,and the shed will be removed. The septic system will be capped and filled. The southern portion,the 70 Stage Coach Road lot is treed. That area is to be developed with the 12 units of multi-family housing to be known as"Stage Coach Residences". 4. Stage Coach Residences is to total 12 units of affordable housing consisting of six(6)one-bedroom units, and six(6)two-bedroom units to be constructed within three(3)buildings. Each building is to have four units comprised of two(2)two-bedroom,two-story,townhouse-style units and two(2)one-bedroom, single-level,flat-style units. The development is clustered on the southern portion of the locus and accessed from Stage Coach Road. 5. The northern 4.8-acres,which represents 70%of the locus,is to be retained in an undeveloped natural state for conservation purposes and environmental protection. 6. Massachusetts Housing Partnership(MHP)has reviewed the proposal for funding under the Neighborhood Rental Initiative Program and on October 21,2009 issued a Project Eligibility letter to the Barnstable Housing Authority for Stage Coach Residences. The letter was issued under the affordable housing regulations of the Commonwealth, MGL Chapter 4oB and CMR 76o Section 56. The issuance of that letter confers"standing"for the Applicant to seek a local Comprehensive Permit for the development. 4 7. As of September 29,2009,the Department of Housing and Community Development has certified that 6.6%of the Town of Barnstable's year-round housing stock qualifies as affordable housing. At this point, the Town has not met the Commonwealth's goal of io%of a community's housing stock being dedicated to affordable housing. 8. The Centerville Village Plan of the Town's Local Comprehensive Plan specifically identifies the locus as a desirable site for affordable housing. The Plan promotes a`fair share'of affordable housing throughout all of the villages of the Town. Presently,Centerville has 1.05%affordable housing and this development advances Centerville's fair share of the town's affordable housing goal. . 9. All 12 units will be permanently restricted as affordable housing units rented to individuals and households with an income level not to exceed 6o%of the area median income for the Barnstable Metropolitan Statistical Area(MSA). The monthly unit rents,including utilities,are limited as to not exceed 30%of the 6o%maximum income allowed thereby providing housing to that underserved group that is acutely in need of decent affordable housing. io. The townhouse units are to be i,024 sq.ft.,two-bedroom,1.5 bathroom units and the one level flat type units are to be 711 sq.ft.when on the first floor,or 788 sq.ft.when on the second floor. The sizes of the units exceed the minimum requirements of the Local Initiative Program Guidelines and the bedroom areas exceed the minimum state sanitary code requirements. All of the 9 first floor units will have visitability. One unit will be handicapped accessible and another unit will be designed for the sensory impaired. ii. The Applicant has met with the Centerville Osterville Marstons Mills Fire Department, Barnstable Housing Committee,Site Plan Review Committee and the Town's Growth Management Department. The Housing Committee has unanimously voted to support the proposal as communicated to the Board in its letter of November i7,20o9. The Town's Growth Management Department,in its letter of November 24,2009, expressed its support based upon the proposed development's compliance with the goals of the local comprehensive plan and housing plans. The Town Manager expressed support for the development as stated in his project eligibility application review letter of September 16,2009 to Massachusetts Housing Partnership. 12. The Barnstable Housing Authority has been providing affordable housing in Barnstable for over 6o years. It currently administers some i000 units of housing under a number of local,state and federal programs. The Applicant has a proven track record of developing and operating affordable housing projects. 13. Access to the development will be over Stage Coach Road,a 4o-foot developed private way. Although the Town recently improved drainage in the way,testimony has been presented that the way is still subject to periodic flooding. The Town's Department of Public Works indicates that"the road is passable and no major flooding damage is evident or has been recently reported to the Highway Division." To assure road drainage is not exacerbated by the development,the Applicant has committed to containing all runoff on- site and none will be directed into abutting properties or into the way. ` i4. Based on the Institute of Transportation Engineers(ITE)manual,the estimated vehicle trips from the iz multi-family units is 8o trips on an average weekday. That is less trips than what would be generated from the development of iz single-family detached units.The development of Stage Coach Residences does not represent an overburdening of Stage Coach Road,and will not present a safety issue at the intersection with Old Stage Road as sufficient site distances now exists. i5. Regarding the rights over Stage Coach Road,the Applicant has demonstrated to the Board that regardless of the existing rights or lack of rights,it can secure the right to access the property over Stage Coach Road and has committed to assure those rights exist prior to the implementation of this comprehensive permit. 16. With respect to an encroachment on the subject locus from adjacent neighbors at 79 Three Ponds Drive, this Board finds that issue to be a civil matter;therefore this Board will not address that issue here. i7. The shared septic system has been designed in full compliance with both the local Barnstable Board of Health regulations and Massachusetts Department of Environmental Protection Title 5 regulations without variance. The location of the development and any land disturbance is fully outside of any conservation jurisdictions and there is no need for any Order of Conditions under the State Wetlands Protection Act. 5 I i8. The development has been designed to conserve and protect the natural features of the site. It has been clustered to the far southern z-acres of the 6.9-acre site limiting the extent of site clearing. It is situated well over ioo feet from vegetated wetlands,outside of the jurisdictional concerns of the Conservation Commission. It proposes to preserve 8o%of the site in a natural state with 70%permanently protected with a conservation restriction. i9. The Applicant has agreed,to the extent permissible by law,to implement a local preference for up to 70% of the affordable units for residents of the Town of Barnstable and for persons employed within the Town. 20. In view of the Town's current deficit for affordable housing units and the Applicant's proposal to provide i00%of the units as affordable housing to individuals and households at or below the 6o%median income of the area to the extent allowed by law,this development is consistent with the local needs for the Town of Barnstable as it will serve a population that has been very much neglected and underserved in the creation of affordable housing. Therefore,this Board finds that this proposal is consistent with local needs. The Vote on the grant and conditions of the permit was: AYE: William H. Newton, Michael P. Hersey,Craig G. Larson,George T.Zevitas,James F.McGillen NAY: None Decision and Conditions: Motion: Based upon the findings on consistency with local needs a motion was duly made and seconded to grant Comprehensive Permit No.2009-069 to the Barnstable Housing Authority for the development"Stage Coach Residences"subject to all of the following conditions and restrictions: 1. The total number of housing units shall not exceed 12 units of which six(6)shall be one-bedroom,flat-type units and six(6)two-bedroom townhouse units. All of the units shall be dedicated in perpetuity as affordable rental housing units. The units shall be committed in perpetuity to affordability at 6o%of the median income level to the extent allowed by law to individuals and households in the Barnstable Metropolitan Statistical Area(MSA). Rents for the units(including utilities)shall not exceed 30%of the maximum income figure as applicable and adjusted for individual or household size in perpetuity. 2. All units shall be made available to qualified households on a fair and open basis. An Affordable Housing Restriction reflecting the above restrictions shall be prepared by the Applicant,approved by the Town Attorney's Office,and recorded at the Barnstable County Registry of Deeds by the Applicant prior to any building permits being issued. Such restrictions shall take priority over all financing documents relating to this project. 3. Development of the site shall be in conformance with plans presented to the Board and as modified per Condition No 4 below. The plan set Title Sheet is entitled"Proposed Stage Coach Residences for Barnstable Housing Authority 70 Stage Coach Rd.&151 Oak Street Centerville, MA"dated 1i-o9 as drawn by Architects Brown Linguist Fenuccio&Raber Architects,inc,and Consulting Surveyor's&Civil Engineers J.M.O'Reilly&Associates, Inc.and consisting of eight(8)plan sheets labeled;Ci—Existing Conditions,Cz- Site Grading&Pavement Layout Plan,C3—Sewage Disposal System Design,C4—Drainage Plan,Ai.o-First Floor Plan,Ai.i —Second Floor Plan,A2.0-Conceptual Front Elevation,and Az.i-Conceptual Rear Elevation/Conceptual Left End Elevation. 4. The plans cited above are to be modified to comply with requests made to the Board from: • Martin MacNeely, Fire Prevention Officer,Centerville-Osterville-Marstons Mills Fire Department as per request letter dated November 23,2009, 6 • A 1 • Robert Burgmann, Barnstable Town Engineer, Department of Public Works as per request e-mail dated November 23,2009, • Thomas McKean, Barnstable Director of Health,requests a complete plan review checklist at that time that a sewage disposal permit is sought,3-year septic site inspection requirement,and a proposed dumpster pick-up schedule. • The Board of Health request made to staff at the December 8,2009 meeting of the Board that the leach field vent be screened,the attic under the roof be structured so that there is no habitable space in that attic area,and that the engineer review and verify that there are no private drinking wells within 150 feet of the proposed septic system. • And staff requests that a landscape plan be developed for the site that includes a proposed play area and lighting. This plan(s)shall be in conformance with all applicable zoning requirements. The plans,as modified,shall be submitted for final review by those requesting the changes and cited above. Upon compliance,the entire plan set shall be revised and submitted to Board's staff for their approval prior to any building permit application. No basement area or attic area shall be designed for human habitation. 5. Development of the property shall be limited to the construction of three buildings,each with 4 units. The buildings and all site development is to be clustered to z-acres located and accessed from Stage Coach Road as shown on the plan. The other area of the site,approximately 4.9-acres; is to be dedicated to open space/natural resource protection. A conservation restriction to that effect shall be executed,and a copy of it submitted to the file prior to the issuance of any building permit. 6. All of the first floor units shall be designed for visitability. One of the units shall be designed for handicapped accessibility and another unit designed for the sensory impaired. 7. All required state permits and approvals including but not limited to,Title 5 wastewater disposal permit, and Massachusetts Natural Heritage&Endangered Species Program(NHESP)approval shall be submitted to the Board's file prior to the issuance of a building permit. 8. Proof of access rights over Stage Coach Road shall be submitted to the Board's file and to the Building Commissioner at the time a building permit is requested for the development of the property. 9. This comprehensive permit is granted with the condition that the proposed development is to be funded under an approved program of the Massachusetts Housing Partnership Fund. If the funding source changes,the Applicant shall be required to notify the Board of a minor modification of this comprehensive permit as set forth in the regulations governing comprehensive permits. No building permit applications shall be made for the development until the applicant receives its final funding approval from MHP and a copy of that approval submitted to the Board's file. io. The conditions contained herein are in addition to,and independent of,any requirements of any funding source for the project. All of the conditions of this decision as set forth herein shall have independent legal significance and effect. ii. The Property shall be addressed and each unit shall be posted in accordance with the Code of the Town of Barnstable General Ordinances,Chapter 51. All signage shall conform to the Town of Barnstable Zoning Ordinances without waiver. 12. Prior to the issuance of any building permit,an Affordable Housing Restriction reflecting the restrictions and consistency with this comprehensive permit,shall be executed by the Applicant, MHP,and the Town of Barnstable. The Applicant shall prepare the restriction and submit it for approval by the Town's Attorney. Notwithstanding Condition 1 above,in the event that the subsidizing agency(MHP)or any 7 lender forecloses on the project,no less than 25%of the units shall remain affordable to individuals and households earning no more than 8o%of the applicable areas median income(AM I)for as long the project remains noncompliant with zoning. Upon being signed,it shall be recorded at the Barnstable County Registry of Deeds by the Applicant against the property and the individual unit. Such restriction shall take priority over all financing documents related to this project and shall survive foreclosure. All costs associated with monitoring for consistency with the Affordable Housing Restriction shall be the responsibility of the Applicant. 13. Prior to the issuance of a Certificate of Occupancy for any unit,the Applicant shall have the development and the unit connected to the public water supply system and to the on-site wastewater treatment system. The Applicant shall be responsible for obtaining all necessary permits including those of the Department of Environmental Protection(DEP),if necessary,and the Town of Barnstable Health Division. 14. To the extent permissible by law,preference for the rental of at least seventy percent(70%)of the units shall be given to households who are Barnstable residents or that have one of the persons within the household employed by businesses located within the town of Barnstable. This local preference shall be implemented at the initial start-up. After the initial start-up,the Applicant shall maintain this 70%local preference to Barnstable residents to the full extent permitted by law. The Applicant,who will have responsibility for managing the development,shall also be responsible for assuring that the local preference is met. 15. A copy of this comprehensive permit shall be recorded at the Barnstable County Registry of Deeds. Proof of that recording shall be submitted to the office of the Zoning Board of Appeals and the Building Department for inclusion into the file prior to the any building permit application for the development. 16. All construction shall comply with all applicable state building codes,state fire protection requirements, and Board of Health regulations and shall contain a fire suppression system(sprinklers). In addition,the development shall conform to all pertinent requirements of the Americans with Disabilities Act. 17. During construction,the Applicant shall at all times use all reasonable means to minimize inconveniences to the abutting residents in the area. Construction activities that cause noise off-site shall not commence on any day before 7:0o a.m. and shall not continue beyond 6:0o p.m. There shall be no construction on any t Sunday or state or federal legal holidays. 18. This comprehensive permit shall not be transferable to another entity other than the applicant without prior written approval of this Board. This condition,however,shall not apply to the use of the permit in securing financing for the development. In the event that the Barnstable Housing Authority becomes a minority owner of the development,that event shall only be permitted provided the Barnstable Housing Authority retains full management of the development and property. 19. The Applicant or a management company shall be responsible for the installation,operation,and maintenance of all aspects of the common facilities and utilities including,but not limited to septic and drainage systems,common electrical power,snow plowing,landscape maintenance,care of the play area, and garbage removal as well as any periodic reporting requirement as may be imposed by the Board of Health. Zo. No certificate of occupancy for any building or unit shall be issued until the improvements specified in this decision and set forth on the plans of record are constructed and installed so as to adequately serve said building,or adequate security has been provided,reasonably acceptable to the Town Engineer and approved by the Town Attorney's Office to ensure such completion.Any such performance guarantee shall be governed by the subdivision rules and regulations of the Planning Board and shall be approved by the Town Attorney's Office. 8 21. All leases shall have a minimum term of one'(i)year.'There shall be no subleasing or subletting of any of the units. The use of the units shall be limited solely for single family residential use. No business activities shall be conducted in any of the units. 22. The Applicant shall contact the other owners of properties on Stage Coach Road in writing by certified and regular mail within 3o days of this decision becoming final,with a required response from such owners no later than 6o days of this decision becoming final,as to whether at least 5i%of such owners agree to jointly file a petition with the Town of Barnstable to either take Stage Coach Road as a Town road or seek its repair under Barnstable's Private Road Program in accordance with Town rules and regulations. Within 75 days of this decision becoming final,the Applicant shall submit a letter to the Barnstable Growth Management Department certifying whether a joint petition will be filed with the Town or not. In either event,such notice to the Barnstable Growth Management Department shall be deemed full compliance with this condition." The Vote on the grant and conditions of the permit was: AYE: William H. Newton, Michael P. Hersey,Craig G. Larson,George T.Zevitas,James F. McGille.n NAY: None Request for Waivers and Variances: Motion: With respect to the Applicant's request for relief from local rules and regulations,the Board finds that certain requested waivers may be granted without adversely affecting the public health and safety of occupants in the development,the surrounding neighborhood,and the residents of the Town of Barnstable, provided the conditions imposed in this permit are strictly followed and adhered to.Therefore,the following waivers are granted to the Barnstable Housing Authority for the development of Stage Coach Residences: 1. Waiver from the following zoning ordinance provisions: • Section 240-7(F)(i)Number of buildings allowed on a lot in residential districts to allow 3 principal buildings on a single lot when zoning only permits one(i)principal building per lot in residential districts. Section 240-i3(A)Principal permitted uses to allow for multi-family use in three buildings where only one,detached,single-family dwelling per lot is permitted. • Section 24o-98 to i05 Site Plan Review,with the exception that the Applicant shall conform to all applicable design standards and as built plans shall be submitted. • And,with respect to the Applicant's proposed development on Parcel 026 of the locus and its association with infringements from Parcel 073,all relevant provisions of the Zoning Ordinance concerning,landscape and perimeter buffers and yard setbacks for the proposed construction are waived only if needed and only to the extent necessary. • Article XI,Growth Management Provisions are waived to allow all of the building permits for the development of the 12 affordable units to be requested at any one time and all to issue at any one time regardless of the time frames imposed by the Growth Management provisions. All building permits shall be included in the counting and number limitations imposed in the Growth Management Ordinance. However,should the requested permit(s)exceed those available at the time the request is made,the Building Commissioner shall issue the permit(s)separate and outside of the limitations imposed in the Ordinance.The building permits,are subject to all other requirements of the Building Division for the issuance of building permits and all requirements of this comprehensive permit decision. 2. With respect to Section 112 of the Code-Protection of Historic Properties,this Board acting on behalf of the Barnstable Historic Commission,finds that the dwelling located at 151 Oak Street,Centerville,MA.does not represent a significant historic,cultural or architectural resource;therefore it is not subject to a demolition delay order. 9 3. Regarding the request for waiver from the filing and permitting fees of all Town agencies and departments,the Zoning Board specifically grants no relief,however,the Applicant may request any reduction in fees directly to the division or agency that imposed the fees. The vote on the grant of the waivers was: AYE: William H. Newton, Michael P. Hersey,Craig G. Larson,George T.Zevitas,James F.McGillen NAY: None Chairman's Order: Comprehensive Permit 2oog-o6g has been granted with conditions. This decision must be recorded at the Barnstable Registry of Deeds for it to be in effect. This decision must be exercised within three years or it shall expire. Appeals of this decision,if any,shall be made to the Barnstable Superior Court pursuant to MGL Chapter 4oA, Section 17,within twenty days after the date of the filing of this decision in the office of the Town Clerk. The applicant has the right to appeal this decision as outlined in MGL Chapter 4oB,Section 22. James F. McGillen,Acting Chairman Date Signed I Linda Hutchenrider,Clerk of the Town of Barnstable, Barnstable County, Massachusetts,hereby certify that twenty(zo)days have elapsed since the Zoning Board of Appeals filed this decision and that no appeal of the decision has been filed in the office of the Town Clerk. Signed and sealed this day of under the pains and penalties of perjury. Linda Hutchenrider,Town Clerk 10 VI. Proposed 18 bedroom Development: Stage Coach Residence—70 Stage Coach Road and 151 Oak Street, Centerville—Sandee Perry, Barnstable Housing Authority, determination of whether a shared IA system shall be required. No one was present from the Barnstable Housing Authority, nor the engineer for the project. The Board reviewed the project which is an 18 bedroom affordable housing project (6 one bedroom and 6 two bedroom) with 4+acres dedicated to Conservation. It is not in a ground water protection zone and does not require a septic variance and has town water. Lot# 151 has a two-bedroom home and shed which will be demolished and removed. This project is a single-owner renting out units. It is categorized as a multi-family unit. There are three separate building and the code considers it a shared system. MA State Code 301 requires the septic system to be inspected at least once every three years. (If there were five or more buildings, the regulation would have required inspection every year.) Mr. Traczyk said the basements will not be vailable for use by the tenants. Art Traczyk, Regulartory/Design Review Planning for Growth Management Department Service to assist the Zoning Board of Appeals, participated in the discussion with the Board. It was determined an Innovative/Alternative System was not required and determined the engineer must identify any private wells within 150 feet of the septic components, In addition to the Board of Health's November 27 email correspondence to ZBA, the Board of Health will add: 1) the attic space under the roof line is not habitable, and 2) provide screening at t�„ hie vent apes to the septic system. the seven page checklist must be completed by the engineer at the time of the septic permit, VII. Old Business/New Business: A. Budget—submitted request for additional funds to manage an escrow account for septic repairs. B. Flu Vaccine Clinics—final Seasonal Flu Vaccine Clinic will be Wed December 9, 2009 at the Senior Center. The H1N1 Vaccine continues to be distributed as quantities are received in. Y t Board of Health Minutes 12/08/09 Page 5 of 5 Excerpt from Board of Health Meeting Minutes 12/08/2009: VI. Proposed 18 bedroom Development: Stage Coach Residence - 70 Stage Coach Road and 151 Oak Street, Centerville -Sandee Perry, Barnstable Housing Authority, determination of whether a shared IA system shall be required. No one was present from the Barnstable Housing Authority, nor the engineer for the project. The Board reviewed the project which is an 18 bedroom affordable housing project (6 one bedroom and 6 two bedroom) with 4+acres dedicated to Conservation. It is not in a ground water protection zone and does not require a septic variance and has town water. Lot# 151 has a two-bedroom home and shed which will be demolished and removed. This project is a single-owner renting out units. It is categorized as a multi-family unit. There are three separate building and the code considers it a shared system. MA State Code 301 requires the septic system to be inspected at least once every three years. (If there were five or more buildings, the regulation would have required inspection every year.) Mr. Traczyk said the basements will not be available for'use by the tenants. Art Traczyk, Regulartory/Design Review Planning for Growth Management Department Service to assist the Zoning Board of Appeals, participated in the discussion with the Board. It was determined an Innovative/Alternative System was not required and determined the engineer must identify any private wells within 150 feet of the septic components. In addition to the Board of Health's November 27 email correspondence to ZBA, the Board of Health will add: 1) the attic space under the roof line is not habitable, and 2) provide screening at the vent pipes to the septic system, the seven page checklist must be completed by the engineer at the time of the septic permit, "Message Page 1 of 2 Crocker, Sharon From: Kevin Maguire [kevin.maguire@buildinginitiatives.com] Sent: Tuesday, November 27, 2012 12:20 PM To: Crocker, Sharon Subject: Re: Stagecoach Residences Thanks so much Sharon. Very helpful to have this clarified. Thank You Kevin Maguire Oxbow Partners 917-340-3187 kevin.maguire@buildinginitiatives.com On Nov 27, 2012, at 10:50 AM, Crocker, Sharon wrote: Good morning Kevin,Tom has spoken with Mi��chael Schultz and they are going to be meeting at 4pm. Tom and Mike have informed me that it will not be necessary to come to the Board meeting December 11. Sorry for the confusion. Thank you*. S Sharon -----Original Message----- From: Kevin Maguire [mailto:kevin.maguire@buildinginitiatives.com] ' l Sent: Monday,November 26, 2012 7:29 PM —e- To: Health r ` ' Cc: Crocker, Sharon y" Subject: Stagecoach Residences Tom- I spoke to Sharon today hoping to confirm whether or not we in fact need to appear at the Board of Health meeting on 12/11. In looking back in the files, it appears that the Alternative Technology question for a 17 bedroom development was raised in your email of November 24, 2009 and subsequently discussed and resolved at the December 9, 2009 BoH meeting. I have attached a copy of your transmittal to Art Traczyk as well as a copy of the 12/8/09 minutes from the BoH meeting. Separately, I realize that the area of the full development needs to be the sum of the 2 parcels owned by the Housing Authority in order for the discharge calculations to work. This modification is in the works but I wasn't sure if we needed to review this issue with the full board. 12/5/2012 .6J "Message Page 2 of 2 Please advise as I want to make sure that we are all on the same page. ThanksTom <BOH minutes and results 12.08.2009 .pdf> <BoH Review and Comments to ZBA.pdf> Thank You Kevin Maguire Oxbow Partners 917-340-3187 kevin.maguire@buildinginitiatives.com j 12/5/2012 e i C �s I Tm — �y I Stg9e �oac6� fl � t � — � Cz ��k� QXBowPartners exceeding expectations Kevin Maguire Peter W Smith Via Hand Delivery October 17, 2012 Laura Shufelt, Chairwomen Barnstable Zoning Board of Appeals 200 Main Street Hyannis, MA 02601 Re: Stage Coach Residences-Centerville,MA Drawing Submission per Staff Approval prior to Building Permit Application per Comprehensive Permit Condition#4 Dear Ms.Shufelt- On behalf of the Barnstable Housing Authority, I am pleased to submit for your review the evolved (pre-building permit)drawings for Stage Coach Residences dated September 17, 2012. Consistent with condition 4 of the comprehensive permit issued on January 21, 2010,we are submitting these drawings for staff review prior to the submission of our building permit application. Please note that this submission includes the following: 1. One Full Sized Set of Site, Landscape,Architectural and MEPS Drawings; 2. A copy of the recorded Comprehensive Permit; 3.A matrix which summarizes the comments received by the Town in the permitting process and the response as included in the drawing submission. These comments were specifically detailed in Condition#4 of the Comprehensive Permit; 4.A copy of the draft Management Plan for the development(page 10 address two issues raised in Condition#4); S.A copy of the Septic Design Review Checklist which will be included as part of the submission of the building permit. Our goal is to submit an Application for Building Permit by November 9th. Please let us know if there is anything we can do(including a sit down review of the documents with staff)to assist in your review. If you have any questions, please feel free to give me a call at 917-340-3187 or via email at kevin.maguire@buildinginitiatives.com. Sincerely, L/e�j 4#� Kevin guire 917 � I — �1 Oxbow Partner cc: Sandee Perry, Lord Finton-BHA Tim Sawyer, Maria Rabia,John O'Reilly, Peter Smith 75 arlington st.suite 500.boston.ma.02116 Department Comments to be Addressed in Final Plans Summary for Team Reivew and Comment Martin MacNeel -Fire Prevention Resolution 1 Roadway and Parking Layout per 4/20/09 Plans Compelte 2 Fire Hydrant Placement per 4/20/09 Plans Location Modified per Meeting between Keith Fernandez and Martin MacNeely 3 All Buildings Protected by Automatic Fire Sprinkler Systems Complete 4 Fire Department Connections at Buildings per 4/20/09 Plans Complete S Fire Lane striping and/or signage in parking area adjacent to fire department connection Complete 6 Rework Utilities so that Catch Basins 2&3 do not conflict with Service to Northern Most Building Complete Bob Burgmann-November 23,2009 Email 1 Confirmation that No Assistance from Town on Road Maintenance Agreed 2 Sidewalks to Conform to Town Standards-Can not tell from Permit Drawings Confirmed 3 Identify which unit is ADA Confirmed 4 Identify ADA parking to support the ADA Unit with required ramps Confirmed 5 Rework Locations Where Cape Cod Berm shown abutting sidewalk Complete 6 Rework Utilities so that Catch Basins 2&3 do not conflict with Service to Northern Most Building Complete 7 Eliminate Cost of Nrotherly 20'of Proposed Guardrail Complete 8 Grading at Front of Buiding to Take water around/away from Buildings Reviewed and Modified per Meeting between Keith Fernandez and Steve Seymour 9 General Review of Detail of Drainage Basin Reviewed and Modified per Meeting between Keith Fernandez and Steve Seymour 10 Coordinate Rim Elevations for Catch Basins 1,2&3 Complete 11 On sloped Driveway,set catch basins at the gutter line(eliminate bulbouts at the basins) Reviewed and Agreed per Meeting between Keith Fernandez and Steve Seymour 12 Eliminate Encroaching Pool,Trampoline,etc. Complete ------------- tr Tom McKean Director of Health y r Plan Review Checklist at time of applying for sewage disposal permit t Included as Part-of this-Paekag-e� r2 Ope�atingPlan toinclude 3 year site inspections rReference page 10 of the attached Management Plan for the development yF3 Operating Planan[o incindude a proposed trash dumpster pick upschedule /r •Reference page 10 of the attached Managirnent"Plan for the-developrrSent-7 Board of Health 1 Leach Field Vent to be Screened Confirmed 2 Attic structured so that no habitable space Confirmed 3 Design Engineer confirm there are no private drinking wells within 150 ft of proposed septic system Confirmed BA Staff 1 Submit Landscape Plan including a proposed play area and lighting - Landscape Plans Completed and Included in Current Drawing Package —J MANAGEMENT PLANT i FOR Stage Coach Residences Fb Equal Housing Opportunity j Barnstable Housing Authority 146 South Street,Hyannis,M4 02601 Tel(508) 771-7222 Fax(508) 778-9312 q T I TABLE OF CONTENTS • OVERVIEW Page 1 • GENERAL INFORMATION • Property Page 1 • Approach to Management 1 Consultations with Mass Housing Partnership • Compliance with Local,State and Federal Laws Page 2 I and Regulations ' • Governing Documents and Authorities • Key Contact Persons • MANAGEMENT OF DEVELOPMENT Page 3. • Personnel o Staffing Plan o Personnel Policy • Tenant Selection o Affirmative Marketing/Outreach o. Tenant Selection Plans Page 4 o Income Eligibility Requirements • Leasing and Lease Enforcement Page 5 o Lease o Security Deposits o Resident Orientation o Emergency Procedures o Lease Enforcement o Termination of Lease Page 6 o Eviction o Unit Inspections o Pet Policy Page 7 ' s Rent Collection Policies and Procedures o Rent Calculation Methodology j o Payment of Rent and Other Charges o Rent and Other Charge Arrears Page 8 o Redetermination of Rent and Family Composition • Maintenance and Repair o Warranty and Preventive Maintenance Procedures Page 9 o Maintenance by Outside Contractors o Emergency Maintenance Repairs o Routine and Minor Repairs • Routine Maintenance Page 10 o Maintenance Assistance Availability . o Annual Inspections 0 , Title V Inspections o Rubbish Removal o Maintenance Charges o Damage Payments o Rent Increases o Vacating Documentation o Major Repairs o Resident Charges Pagel o Vacancy Preparation o Maintenance Records o Authorization for Repairs o Procurement Requirements • Resident Relations o Tenant Concerns o Resident Orientation • Accounting Policies and Procedures Page 12 o Operating and Capital.Budgets o Project Account o Internal Controls • Records and Reports ` o Resident and Unit Maintenance Records o Accounting Records Page 13 o Reports o Audit i II • OVERVIEW i Barnstable Housing Authority is a public housing agency established in 1948 under j Chapter 121 B. In response to the need for affordable housing in the Town of Barnstable, the Barnstable Housing Authority has developed twelve additional affordable units to be known as Stage Coach Residences in response to this need within the community.The agency's mission statement is as follows: THE BARNSTABLE HOUSING AUTHORITY IS COMMITTED TO ENSURING SAFE,DECENT,AND AFFORDABLE HOUSING FOR THE CITIZENS OF BARNSTABLE AND THE COMMONWEALTH. THE BHA SHALL STRIVE TO CREATE OPPORTUNITIES FOR RESIDENTS' SELF SUFFICIENCY AND ECONOMIC INDEPENDENCE AND ASSURE FISCAL INTEGRITY BY ALL PROGRAM PARTICIPANTS. THE EFFECTIVENESS OF THESE ENDEAVORS WILL BE ENHANCED BY DEDICATION TO EFFICIENT PROGRAM MANAGEMENT AND COLLABORATION WITH RESIDENTS,COMMUNITY SERVICE PROVIDERS,AND GOVERNMENT LEADERS. • GENERAL INFORMATION Property & Management Stage Coach Residences is located at 70 Stage Coach Road,Centerville,MA 02632,and will be owned and managed by the Barnstable Housing Authority. Six of the units will be subsidized with Section 8 Project Based Vouchers approved by DHCD and administered by Housing Assistance Corporation. Six units will be low income rent assisted for families and individuals at or below 60%of the Area Median Income(AMI) for the Town of Barnstable. Currently that AMI for Barnstable is$80,000. All units will remain affordable in perpetuity. • Consultations with Mass Housing Partnership j o Barnstable Mousing Authority will consult with the Mass Housing Partnership j before taking action under the following conditions: o Before making any substantial capital improvements to the property that are not included and/or approved in the budget. o Or otherwise required by the loan documents 1 • Compliance withLocal, State and Federal Laws and Regulations o In the operation of Stage Coach Residences, Barnstable Housing Authority will comply with pertinent local,state and federal laws,codes,`ordinances, regulations and directives,including but not limited to: the United States Housing Act of 1937, as amended;Fair Housing Act,42 U.S.C. 360.1-19; Title VI of the Civil Rights Acts of 1964(Public Law 88-352,78 Stat.241);the Age Discrimination Act of 1975,U.S.C. 6101-07; Section 504 of the Rehabilitation Act of 1973;the Americans with Disabilities'Act,42 U.S.C.�12181-89;all requirements imposed by or pursuant to the Regulations of HUD(24 CFR) issued pursuant to those laws;regulations issued pursuant to Executive Order 11063;and Title VIII of the 1968 Civil Rights Act. • Governing Documents and .Authorities o The units at Stage Coach Residences have been acquired utilizing funds from various sources including but not limited.to: Mass Housing Partnership NRI,the Commonwealth of Massachusetts through its Affordable Housing Trust and HOME Program,Barnstable Housing Authority,Town of Barnstable Community Preservation Funds,Town of Barnstable Affordable Housing and Economic Development Trust Fund,Local HOME funds. Therefore,.these units are subject to applicable state and federal rules and regulations relative to those programs. Also,the units are receiving on-going project-based Section 8 rental subsidies from Department of Housing 8z Community Development through the regional non-profit Housing Assistance,Corporation,and are subject to applicable federal rules and regulations governing that program. • Key Contact Persons o The following persons are the key contacts for the various entities involved in the ownership and operation of Stage Coach Residences: o Owner: Chairperson,BHA Board of Commissioners c/o 146 South Street,Hyannis,MA 02601 .Tel: (508)771-7222 q o Managing'Agent Executive Director 3 + Barnstable Housing Authority 146 South Street,Hyannis,MA 02601 Tel: (508)771 7222 2 ® MANAGEMENT OF DEVELOPMENT • The Barnstable Housing Authority will maintain the development both administratively and structurally in accordance with policies and procedures contained in the agency's two volume management manual. • Staffing Plan • The BHA shall be responsible for the overall administration,management and maintenance of Stage Coach Residences. Daily property management shall consist of a combination of the BHA Affordable Housing Coordinator,who shall be responsible for the day-today operations,and shall report directly to the Executive Director. BHA staff members are trained in federal,state and local housing-programs,including reporting, accounting,budgeting and enforcing operational policies and procedures for the programs.The BHA Affordable Housing Coordinator's position will be increased from 25 hours per week to 35 hours to absorb additional administrative and property management responsibilities for the Stage Coach Residences site. Wait list administration and Tenant Selection will be conducted by BHA Tenant Selection Department. • BHA staff will handle other functions,such as financial oversight,occupancy, maintenance and capital improvements. o Personnel Policy • The Barnstable Housing Authority has written personnel policies and practices that conform to non-discriminatory and equal'employment opportunity requirements in its hiring and employment practices. -Applicants and employees will not be discriminated against because of age,cacti;color,creed,national origin,ancestry,disability, sexual orientation,marital status,or family status. The BHA is committed to a policy to assure equal opportunity in employment,and affirmative action to provide employment opportunities for residents,minority,women,and persons with disabilities. • Tenant Selection o Affirmative Marketing/Outreach • Barnstable Housing Authority will conduct outreach for this new development under the guidelines of its Equal Opportunity Housing Plan. Under this Plan BHA will utilize all sources of local media such as: Cape Cod Times(regional newspaper),local town news media throughout Cape Cod,local churches,social service agencies and community groups such as: Cape NAACP, Community Action Committee,Housing Assistance Corporation,Legal.Services,Nam Vets Association,and.Wampanoag Tribal Council,to notify the general public who would be interested in applying for tenancy at Stage Coach Residences.Electronic media such as Barnstable Housing Authority and Town of 3 F Barnstable web sites and local Channel 18 Public Service TV will also be accessed for marketing of this development. o Tenant Selection Plan • Six Project Based.Section 8 Vouchers will be provided by Department of Housing & a Community Development (DHCD). These vouchers are to'be administered by the regional a non-profit,Housing Assistance Corporation. The PBV will be assigned to four 2BR and two 1 BR units at the site. Three units will be targeted to families at or below 50% of AMI and three will be targeted to families at or below 301/o of the AMI. Housing Assistance Corporation (HAC) has been deemed the administrator of these vouchers by DHCD, both BHA and HAC work very well together. Barnstable Housing Authority currently utilizes n HAC's Section 8 wait list to re-issue its Section 8 Housing Choice Vouchers. Rents will be established. using HAC's approved Applicable Payment Standards based on HUD's Fair Market Rent schedule for the Town of Barnstable. Six of the units,two 2BR and four 1BRs will be low-income rent assisted. Eligible families and individuals at or below 60% AMI, will rent units that are low-income rent assisted. • All tenants residing at the site will be responsible to pay the utilities(except water)within the units and BHA's utility allowance schedule will be used to calculate rental amounts, Eligible families will not pay more than 30%of their income for rent. • In addition to income eligibility, all applicants will be screened for appropriateness for program participation by using landlord references, CORI, and SORT documents. A five year housing history.for each applicant will be required at the time of application for screening purposes. Admission will be prohibited for any household: subject to a life time registration requirement under State sex offender registration program, with a history of drug distribution, violent behavior, or any•behavior which exhibited in public .housing would threaten the health, safety or peaceful enjoyment of other tenants in the development. Applicant households determined ineligible due to past housing history, CORI, SORI,drugs or violence, will be allowed to request a hearing to present a request for redetermination based on mitigating circumstances to the Executive Director. o Income Eligibility Requirements No household will be admitted to a Stage Coach Residences housing unit whose income and assets exceeds applicable limits established for the Section 8 program or exceed the specified percentage of Area Median Income required by the sources of fimds utilized to acquire the particular unit,whichever is lower. d I • d 4 • Leasing and Lease Enforcement o Lease I o A lease will be executed between the Barnstable Housing Authority and each tenant household upon occupancy,and a copy of the executed lease agreement will be provided for inclusion in the resident folder. The term of the lease agreement will be for one year which will automatically self renew from year to year unless otherwise terminated in accordance with its terms and conditions. The lease agreement is to be kept current at all times,reflect the rent being charged,and state the conditions of occupancy. o Security Deposits o Every new resident will be required to pay a security deposit prior to occupancy in an amount as established by BHA's Rental Acquisition Program(RAP) Security Deposit Policy. Security deposits will be held by the Barnstable Housing Authority in a special escrow bank account and will be returned to the resident plus any accrued interest within 30 days of the termination of his/her tenancy if the apartment is left in a satisfactory condition and full notice was given for termination by the resident. If damages beyond normal wear and tear have occurred and are attributed to the tenant,the tenant shall be charged accordingly and deductions made from the security deposit shall be itemized and forwarded to the tenant along with any remaining balance. o Resident Orientation o All new residents will be required to participate in a tenant orientation program to familiarize themselves with the policies and procedures of the building at the time of lease execution. This orientation program will be performed by the BHA Affordable Housing Coordinator,and will cover the lease;rules and regulations; maintenance and repair policy;rent collection;and housekeeping. o Emergency Procedures o The BHA Affordable Housing Coordinator shall instruct all residents on the proper procedures to follow in the event of a general maintenance,fire,or medical emergency. o Lease Enforcement o The Barnstable Housing Authority is responsible for ensuring the full compliance of the terms of the lease by all residents. All provisions of the lease will be thoroughly explained to the resident by the Affordable Housing Coordinator at the time leases are signed. The Affordable Housing Coordinator will emphasize voluntary lease compliance. 5 o The Barnstable Housing Authority will initiate a lawful termination of a tenancy where there is sufficient cause(including,but not limited to non payment of rent)that a tenant has violated.a term of his/her lease. The Barnstable Housing Authority will provide written notice of lease termination in accordance with th the provisions of the lease and with any applicable requirements of local law. I o Termination of Lease o A tenant must give 30 days prior written notice of intent to terminate the lease. The Barnstable Housing Authority may terminate the lease when a tenant violates the terms of its lease. The Barnstable Housing Authority may also elect not to renew a tenant's lease. o Eviction o The Barnstable Housing Authority shall consult with legal counsel of its choice to bring actions for evictions in the name of the BHA,and to execute notices to vacate and judicial pleadings required by such actions. o Unit Inspections o The Affordable.Housing Coordinator will conduct a move-in inspection with a . g mspec new tenant prior to the tenant signing the lease. The.overall condition of the unit and provided equipment shall be adequately documented in an inspection report forma executed by the BHA Maintenance Supervisor prior to lease up of the unit, and the inspection report form shall be signed by both the BHA and the tenant. The Housing Assistance Corporation,which oversees DHCD's Section 8 program,will conduct an independent inspection in accordance with the requirements of the Section 8 program,with respect to the six project based vouchers where Section 8 is used. o The Affordable Housing Coordinator along with a member of the BHA Maintenance staff will annually inspect each unit prior to the lease renewal date to check on housekeeping,maintenance, and other lease compliance issues. The Housing Assistance Corporation's Section 8 staff will schedule an inspection of each PBV unit annually prior to the lease renewal date to confirm continued compliance with Section 8 program requirements,at the six PBV units where Section 8 Program is in force. 1 o When a tenant initiated lease termination notice is received,the Affordable Housing Coordinator shall conduct a unit inspection with the outgoing tenant prior to keys being handed in. The tenant shall be notified and charged for any tenant caused damages beyond normal wear and tear in accordance with the security deposit law. 6 - I o The Barnstable Housing Authority at its sole discretion may randomly and periodically inspect units when it believes there are reasonable grounds for an inspection,and with proper notice to the tenant. o Copies of all unit inspections shall be kept in both tenant and unit files. o Pet Policy o No pets will be allowed at Stage Coach Residences. • Rent Collection Policies and Procedures • Location to Send Rent Payments. All payments must be made by check or money order to Barnstable Housing Authority,and shall be mailed or delivered to its office at 146 South Street,Hyannis,MA 02601,and clearly marked Stage Coach Residences,Unit#included. o Rent Calculation Methodology o The tenant's portion of the rent will be equal to 30°/a of their income as calculated by the Barnstable Housing Authority for the six low rent income based units. Housing Assistance Corporation shall use the method and income limits established by DHCD under HUD's Section 8 Program for the six PBV units. The Housing Assistance Corporation,as administrator.of DHCD's Section 8 Program,will verify income and calculate rent in accordance with standard practices and procedures,and subtract the appropriate utility allowance as tenants are responsible for the electricity and gas usage in their units. Cable service is not considered a utility. HAC has agreed to use Barnstable Housing Authority's Utility Allowance schedule for calculating the Total Tenant Payment under the Section 8 Program. o The BHA Affordable Housing Coordinator will determine rents for the six low income units based on rents set according to 60%and below AMI for the Town of Barnstable. Eligible tenants will not pay any more than 30%of their income for rent and will be responsible for paying for their own electricity,gas,and cable TV usage in their units. BHA will pay for water and sewer charges as well as any common space gas and utility usage. :I o Payment of Rent and Other Charges o Rents are due and payable on or before the first day of each month. Each month, the BHA Fiscal Office will review rent collection activity and issue late rent/service fee notices with a copy to the Afffordable Housing Coordinator. A a late fee of$25.00 will be assessed to tenants on the last day of each month where rents have not been paid. o The Affordable Housing Coordinator will consult with an attorney of the Barnstable Housing Authority's choice and begin eviction proceedings against i tenants whose rents are 14 days or more late and have not entered into and adhered to a mutually agreed upon repayment plan. o Rent and Other Charge Arrears • The BHA Fiscal Office shall issue late rent notices to residents who have not paid their rent by the 7a'day of the month and prepare a notice to terminate tenancy(i.e.fourteen day notices)for delivery by a constable to residents who have not paid their rent by the 15th day of the month. If a resident remains in arrears after that period,the BHA may contact its attorney so it may bring legal action for eviction in accordance with the terms of lease.The Barnstable Housing Authority shall make every effort to secure voluntary compliance by each resident with the terms of his or her lease.Repayment agreements shall be offered based on consultation with the tenant and for good cause. Non- compliance with a voluntary repayment agreement will be cause for legal action through the court requesting that BHA be,granted possession of the unit. o Redetermination Of Rent And Family Composition Changes • The income,allowances,and family composition of each household will be re- determined at least once a year in accordance with the Section 8 recertification policy followed by the Housing Assistance Corporation in its Section 8 Administrative Plan and in accordance with the requirements of Department of Housing&Community Development and(DHCD)&Department of Housing Urban Development(HUD). • Households with low rent assisted units will have the income,allowances and family composition of each household re-determined annually by the BHA Affordable Housing Coordinator in accordance with the programmatic requirements of the funding agencies. • Maintenance and Repair • The Barnstable Housing Authority shall be responsible for overseeing maintenance and , repairs that include,but are not limited to; general maintenance,trash collection, landscaping,procuring and administering ongoing maintenance contracts(such as heating and air conditioning equipment),extraordinary maintenance, emergency repairs,pest extermination,and other maintenance and repair work as may be necessary to keep the units/buildings in decent,safe,and sanitary condition and in a condition that is at all times acceptable: l 8. i o Warranty and Preventive Maintenance Procedures • The Barnstable Housing Authority will maintain and exercise all warranties for all I equipment,appliances,building components,and so forth in existence at the property. The BHA will develop a budget,and schedule of preventive maintenance activities for mechanical equipment,appliance and general maintenance in accordance with operating procedures and industry standards. The BHA Maintenance Supervisor will test and inspect the mechanical equipment and appliances in accordance with preventive I maintenance schedule. o Maintenance by Outside Contractors • The Barnstable Housing Authority shall contract with qualified independent contractors for repair beyond the capability of the regular maintenance staff. In all instances,the BHA Maintenance Supervisor shall inspect and approve completed work prior to payment. o Emergency Maintenance Repairs • Maintenance assistance will be available 24 hours per day, seven days a week by calling the Barnstable Housing Authority at 50$-771-7222. The Barnstable Housing Authority shall receive and service all emergency maintenance repair calls on a twenty-four hour basis. An emergency is defined as a problem that could result in harm to a tenant or building occupant,or to the building/property. All emergency repairs will be repaired or abated within 24 hours. o Routine and Minor,Repairs •• The Barnstable Housing Authority shall ensure that routine and/or minor repairs are performed in an efficient, effective,and timely manner. Electrical,plumbing,and heating repairs which require the services of a licensed technician;will be made by service companies,or,if available,the BHA's skilled maintenance staff. In all instances, the BHA Maintenance Supervisor shall supervise and inspect completed work performed by a licensed technician/service company,prior to any payment for services. • The BHA will ensure that routine and/or minor repairs are completed with reasonable promptness,which typically will not exceed twenty-one days. o Major Repairs j e The Executive Director will review unbudgeted major repairs(i.e.extraordinary maintenance)in excess of$5,0.00 with the BHA Maintenance Supervisor before any 1 work proceeds,emergencies excluded. BHA Executive Director shall not allow major changes,additions,or improvements to the units without the BHA Board of A Commissioners' prior approval. 9 I i I o Routine Maintenance ' • Maintenance assistance will be available 24 hours per day, seven days a week by calling the Barnstable Housing Authority at 508-771-7222. Routine maintenance will be handled during the agency business hours,with an answering service available to forward emergency maintenance calls to a staff member on call for such emergencies during non- business hours. Maintenance of the Stage Coach Residence units will become part of the responsibilities handled by the BHA six member maintenance staff. Some maintenance responsibilities will be contracted out, such as snow plowing, rubbish removal, and HVAC. • Annual unit inspections will be conducted with administrative staff as well as maintenance. • As required by the Town of Barnstable Board of Health, the Stage Coach Residences , Title V septic system will be inspected every three years by a licensed septic inspection company. Results will be reported to the Board of Health. • Rubbish removal will be the responsibility of the BHA. A dumpster for regular trash and one for recycling will be provided at the site for tenants' use. The BHA will include Stage Coach Residences.in its existing contract with a rubbish removal company to , empty the dumpsters weekly. at Maintenance.Charges. The Affordable Housing Coordinator shall notify tenants in writing when charges for maintenance repair and other services are assessed for damages s over and above normal wear and tear. These charges shall become due and payable 14 calendar days after the Affordable Housing Coordinator has notified the tenant. • All damage payments must be made by check or money order to Barnstable_Housing Authority,and shall be.mailed or delivered to its office at 146 South Street,Hyannis,MA 02601,and clearly marked Stage Coach Residences,.Unit##included. • Increases in rent shall be effective on the scheduled recertification date,with 30 days advance notice,provided the tenant has complied with all reporting requirements. Decreases in rent shall take effect on the first day of the month after the month in which the change was reported and verified. • A tenant is required to report changes in household composition within 10 days of the change. Interim certifications,are allowed, and will conform to the Section 8 Program's and low income rent assisted program policy. • No other new household member may added to a tenant's lease until the required information has been provided and the eligibility criteria and the occupancy standards of the Tenant Selection Plan as applicable have been met. In addition, Section 8 Program participants must apply to HAC to add a household member to their lease 10 i • If a family member has vacated the household,acceptable documentation must be provided to prove this within a timely fashion. ' o Resident Charges • The Barnstable Housing Authority shall charge and bill a tenant for any misuse or damage to the unit or building caused by the tenant or his/her guest. The`BHA has developed an itemized listing of additional resident charges,including charges for lockouts,and provided said listing to tenants at lease up and on an as needed basis. r o Vacancy Preparation • Prior to a move-out,the Affordable Housing Coordinator will inspect the apartment. All tenant-caused damages will be noted and reported to the BHA Fiscal Office for possible charges to the former tenant. The Affordable Housing Coordinator,utilizing the services of the BHA's maintenance supervisor,will ensure that identified work be completed immediately after the unit is vacated so the unit can be readied for re-occupancy to occur in a timely manner and vacancy loss minimized. o Procurement Requirements • Management,in conformance with the BHA's Procurement Policy as it may be amended contracts materials supplies,-utilities and services for from time to time shall obtain pp , a LLC units in accordance with all applicable provisions of M.G.L.Chapter 30B;M.G.L. Chapter 30,Section 39M;and M.G.L.Chapter 149 Sections 44 A.-J,as well as federal procurement requirements as applicable. • Resident Relations o Tenant Concerns • Residents will be encouraged to report any problems, issues or concerns to BHA Affordable Housing Coordinator directly. o Resident Orientation • BHA Affordable Housing Coordinator will provide a detailed orientation to each resident upon move-in. The orientation shall cover the lease,occupancy agreement, development j rules and regulations,maintenance and repair policy,rent collection,housekeeping,and operation of equipment within the apartment. 11 • Accounting Policies and Procedures o Operating`and Capital Budgets ' 1 • The Barnstable Housing Authority will prepare and submit draft operating and capital y budgets for every fiscal year(which shall operate from January 1 through December 31), and will submit it to the BHA Board of Commissioners at least sixty(60)days before the beginning of each new fiscal year. The Board of Commissioners will review and approve the operating and capital budgets annually. Annual disbursements for each type of operating and capital expense outlined in the budgets shall not exceed the amount authorized therein. o Project Account • The Barnstable Housing Authority will maintain a separate bank account in its name and shall be designated as the"Stage Coach Residences Operating Account". All receipts of the project or on behalf of the project arising from the operation of the development shall be deposited by the Barnstable Housing Authority into the account. The Barnstable Housing Authority shall utilize funds from the Operating Account to pay utilities, management and maintenance fees,insurance,mortgage payments,and other project expenses. o Internal Controls • The Barnstable Housing Authority will include Stage Coach Residences as a separate program in its computerized accounting services. The annual operating and capital budgets,carrying charge collections,vacancies,bills, et cetera will be entered into.the computer at the end of each month in conformance with its routine financial preparation and administration.After the end of each month,the information will be forwarded to BHA's Fee Accountant(as is the practice for all programs operated by the BHA)and reports_will be generated. ® Records.and Reports o Resident and Unit Maintenance Records • Resident and unit maintenance records,including all leases,Move-In/Move-Out inspection forms,and other resident or unit-related items shall be maintained by the Barnstable Housing Authority at its administrative office. o Accounting Records • The Barnstable Housing Authority will be responsible for overseeing the program's 4 financial books,records,and accounts,including rent roll,bank statements,paid invoices, checks,canceled checks,and all other financial documents related to the Stage Coach Residences development,and will make them available for examination at all reasonable times for compliance with monitoring requirements as set by the funding agents. . 12 o Reports • The Barnstable Housing Authority will prepare in a timely fashion,reports as required by the regulatory and funding agencies, and Management Agreement,in conformance with federal,state and local agency requirements. Reports shall include but not be limited to: occupancy,management,maintenance update reports,financial and accounting reports as necessary and warranted, and all necessary other reports as may be.required by regulatory agencies. • Audit ' I • Barnstable Housing Authority procures an annual audit from an independent accounting firm as required by HUD's Single Audit Act. Stage Coach Residences' financial information will be included in this annual audit. • s 13 r .y J.M. O'Reilly & Associates, Inc. LETTER OF Engineering& Land Surveying Services 1573 Main Street,2nd Floor,P.O.Box 1773 TRANSMITTAL Brewster,MA 02631 (508)896-6601 Fax(508)896-6602 TO: DATE: JOB NUMBER: Town of Barnstable Fog/16/0209 4515 Board of Health 367 Main Street REGARDING: Hyannis, MA 02601 Map 173 Parcel 026 Shipping Method: Locus: 70 Stage Coach, Centerville Regular Mail Barnstable Housing Authority g ❑✓ Federal Express ® 146 South Street Certified Mail D UPS ❑ Hyannis, MA 02601 Priority Mail Pick Up ❑ Express Mail Hand Deliver ❑ COPIES DATE DESCRIPTION Soil Suitability Assessment for Sewage Disposal Report For review and comment: ❑ For approval: As Requested: er your us€ 0. REMARKS: v 22 coo w r" cc: John M. O'Reilly, P.E., P.L.S. Barnstable Housing Authority,Attn: Sandee Perry From: Patricia M. Desjardins If enclosures are not as noted,kindly notify us at once Town of Barnstable P# /CA an+E rq� Department of Regulatory Services •.APOMA M: Public Health Division Date �J 200 Main Street,Hyannis MA 02601 l , Date Scheduled ! VTime / Fee Pd. � Soil Suitability Assessment for Sewage Disposal Performed By: Keith E. Fernandes, EIT wtoessedBy: Donald Desarais LOCATION&;GENERAL INFORMATION Location Address Owner's Name 70 Stage Coach Drive �dqrnstable Housing Auth CeAssessoes nterville Keith E. Ferntdes ELT pMarcel: 1/]3/026 Engineer's Nan- t , T NEW CONSTRUCIION i/ REPAIR Telephone# J.M. O'Reilly & Assoc Land Use Volt slop-0/0 varies Surface Stones NIA /y� M /y�f Distances from: Open Water Body 71M 1 ft Possible Wet Area>100 ft Drinking Water Well�w ft 1 — --F —t oo Drainage Way ft Property Line 7 10 ft Other ft SKETCH:(Street name,dimensions of lot,exact locations of test holes&pert tests,locate wetlands in proximity to holes) 252.94' I - �7 IaD C> t " .. 303.34 � . I Parent material(geologic) 0utyggsh Plain Depth to Bedrock !W A Depth to Groundwater. Standing Water in Hole: N/A Weeping from Pit Face L y A Estimated Seasonal High Groundwater Pb 4n llylater ESP m nt erect DETE TION FORSEAS NAL HIGH WATER TABLE Method Used. D ter en:Al.>l1 Depth Observed standing in obs.hole: in. Depth to soil mottles: in. Depth to weeping from side of obs.hole: - in. Groundwater Adjustment ft. Index Well# Reading Date: Index Well level Adj.£actor Adj.Groundwater Level_ PERCOLATION VEST .paterme Observation Hole# 1N2 It//4 Time at 9" 3 45 11 y� Depth of Pero 56 57It Time at 6" 8:30 Start Pre-soak Time Q qq 0 /y 0 Time(9"-C) 4:45 . End Pre-soak 12:00 15:00 Rate MinAnch L 2 -2 Site Suitability Assessment: Site Passed X Site Failed: Additional Testing Needed(Y/N) N Original: Public Health Division Observation Hole Data To Be Completed on Back------ ***If percolation test is to be conducted within 100'of wetland,you must first notify the Barnstable Conservation Division at least one(1)week prior to beginning. Q:VSEPT1C\PERCFORM.DOC 1 DEEP.OBSERVATION-HOLE LOG Hole'# Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) - Mottling (Structure,Stones,Boulders. onsistency.% .ravel)_ 0-7 O/E Sandy Loam 10yr 6/3 nom 7-27 B Sat* Loan 10yr 5/8 Wane 27/114 C1 Q avelly loany sand 10Ur 6/6 none 5-1CP/cobbles/ 5(7/ gravel 114/163 C2 Maj/Goarse sand 10yr 8/4 none DEEP OBSERVATION HOLE LOG' Hole Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders. Consistency%Gravel) 0-7 O/E SaI>Giy Loam 10yr 6/2 Hole 7-20 R SMCIV I o m 1 Qx, 5& none 20/79 CL Loamy coarse sand 10,�r 6/6 none 20-39/ gravel 79/139 C2 Hxdiw coarse sand 10yr 8/4 Wane DEEP OBSERVATION HOLE LOG i Hole# 1. .: Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders. Consistency-%Gravel 0-7 OX Sandy Loan 10yr 6/3 na-le 7/29 B Sourly LIom LOg 5/8 Hale 29/84 CL Loarly coarse sand 10yr 6/6 nale3CP/ rev 5/ cobbles 84/146 C2 Meaun coarse sand 10yr 8/4 Done DEEROBSERVATION HOLE LOG Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell)_ Mottling (Structure,Stones,Boulders. Consistency,%Gravel) 0-7 O/E Sandy loan 10yr 6/3 node 7/29 B SaDJY loan 10vr 5/8 none 29/65 Cl Lgmy coarse sad !Qyr 6/6 Wane 20-ff/ pawl/ 5-1Cf/ cobbles 65/120 C2 IIBJ un curse mad 10yr 8/4 none Flood Insurance Rate Mal Above 500 year flood boundary No_ Yes Within 500 year boundary No X Yes Within 100 year flood boundary No X Yes Depth of Naturally Occurrine Pervious Material Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the area proposed for the soil absorption system? }yes If not,what is the depth of naturally occurring pervious material? Certification 10/24/05 I certify that on (date)I have passed the soil evaluator examination approved by the Department of Environmental Protection and that the above analysis was performed by me consistent with the required trai g,ex ertise an experience described in 310 CMR 15.017. /J Signature G%����� Date Q:)SEPTIC)PERCFORM.DOC t tXE Town of Barnstable P# �< �p ip - y p Department of Regulatory Services HAANSTAUM Public Health Division Date MASS �(7 67q. �e 200 Main Street,Hyannis MA 02601 piF�MPS A Date Scheduled Time Fee Pd. Soil Suitability Assessment for S a e Disposal oPerformed By: Witnessed By: LOCATION&GENERAL INFORMATION Location Address Owner's Name1cn8ab�2.'. . -10 SANe Coach Rc� C d t Address°`x%it'l kono A��or, 1 I Q Sov�h 51 , an nt 5 Assessor's Map/Parcel: (,3/t7 a(� Engineer's Name J _tin O•Re-,l+ - Asia NEW CONSTRUCTION REPAIR Telephone# Land Use V� .�At-_,I�_--V Slopes(%) G� Surface Stones Iv y !1 � Distances from: Open Water Body /I Q> -ft Possible Wet Area�ft Drinking Water Well 7100 ft Drainage Way 4�0 1(00 It Property Line-_LV ft Other. ft SKETCH_(Street name,dimensions of lot,exact locations of test holes&Pere tests,locate wetlands in proximity to holes) 252.94' cu W .V Cu TP#5 r TP#6 _ r P Ga r rt pp1 ""tea Parent material(geologic) v Wc,Sh- K 1^ —Depth to Bedrock Depth to Groundwater. Standing Water in,4Hole:� Weeping from Pit Face �,,e Estimated Seasonal High Groundwater N f�- OAAef �n c c,,j ' e 1 0 .. •`,,.,.,, _TERMINAT ON FOR SEASONAL,.HIGH`WATER TABLE' 1 . Method Used: ��t r eA f i_ Depth Observed nding in o s.hole: in. Depth to soil mottles: in. # Depth to weeping from side of obs.hole: in. Groundwater Adjustment & Index Well# Reading Date: Index Well level Adj.factor Adj.Groundwater Level PERCOLATION TEST Date Time!_t9C3 Observation Hole# _ Time at 9" Z- r 1r ` t Depth of Pere �x �o��GM 6 T 1�d�� Time at I' _ Start Pre-soak Time r+ O Time(9"-6") 4 End Pre-soak .. . L i Rate MinAnch LZMtn Ii01t.,1 Y ' 1 - Site Suitability Assessment: Site Passed Site Failed:- Additional Testing Needed(Y/N) F Original: Public Health Division Observation Hole Data To Be Completed on Back----------- - ***If percolation test is to be conducted within 100'of wetland,you must first notify the. ' z Barnstable Conservation Division at least one(1)week prior to beginning. Q:\SEPTIC\PERCFORM.DOC - +-' - DEEP OBSERVATION HOLE LOG Bole'# Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Mansell) Mottling (Structure,Stones,Boulders.• - �-{ Consistency,%Gravel) . IQ o-S US p (L ty N A L iS--I cTi nL soevck o Q DEEP OBSERVATION HOLE LOG' ' Hole#` Z . . ... ... .._ Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders. Consistency,%Graven LS 6 ,578, Z5=121 DEEP OBSERVATION HOLE LOG`" Hole# Depth from Soil Horizon Soil Texture Soil Color Soil Other - - Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders. "i Consistency%Gravel) DEEP..OBSERVATION HOLE LOG Hole# Depth from Soil Horizon Soil Texture y Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stones,Boulders. r Consistency.%Gravel) Flood Insurance Rate Mao: Above 500 year flood boundary No���///``` YesY Within 500 year boundary No Yes Within 100 year flood boundary No/I Yes Depth of Naturally Occurring Pervious Material r Does at least four feet of naturally occurring perv,. us aterial exist in all areas observed throughout the area proposed for the soil absorption system? y If not,what is the depth of naturally occurring pervious material? Certification I certify that on (date)1 have passed the soil evaluator examination approved by the } Department of Enviro mental Protection and that the above analysis was performed by me consistent with 5. r the required training,expertise and experience described in 310 CMR 15.017. « v Signaturee; 2 4- Date J !Z • •. Q:\SEPTIC\PERCFORM.DOC - - TOWN OF BARNSTABLE `�� LOCATION Z 9 S L4 Al l es Ld X V SEWAGE # VI1.Li.%GE C eAl re2 ,//l/e ASSESSOR'S MAP & LOT s� INSTALLER'S NAME&PHONE NO. / - A4 A G 0 M XeX ` S 0 Al SEPTIC TANK CAPACITY A S-0 (� LEACHING FACILITY: (type),?—,CoC, ,W 1Ye f?5 (size) i�D0 G 44, NO.OF BEDROOMS y a BUILDER OR OWNER , ff)(-'-"5 WN C-zLr__d PERMITDATE: COMPLIANCE DATE: Separation Distance Between the: Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility Feet Private Water Supply Well Leaching Facility (If any wells exist on site or"within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) Feet Furnished by A t ' s ` I � 1 r STAMP: f Q c 66 U Z D B C D A3.1 I A3.1 A3.1 _I A3.1 Z £ -—- -R' 4 j I pU w$ f-W HEIGHT CEDAR FENCE @ - C c E OF AREAKAY,TYPICAL j' m 3 0 TRENCH DRAIN,SEE �� rD —1,L1_—_—_— _—_h1— CPAL%M 5 OF 5 5' 4'd CZNCRETE PAD D D ZERO 5TEP EIMT W C --- ----------- ---------- --- -- C VINIZA Lu MECHANICAL ROOM MECHANICAL ROOM J O UNITS 1&4 D I 5 - D UNITS 2&3 a Lu = O o I I Ass 14'-I C) � W'-I04' _ �4 Q Lo - -- --- --- ---- 1 ---------- - z_ ( cncz 6-6 J D a U5 A I I a I BASEMENT I D �.l O 0 � C FULL HEIGHT CHAIN I = W LINK PARTITIONS W/ I z W U z V0 WIDE I - LOCKA&.E GATES __j Q Wm O / L ----- -—-—--- -----—--- V N Q U \J g'vl' T-5' 17-1a 13'-6' Pi''�'L� Q z W Lu c CD UNIT#1 UN2 F UNIT 9-1 UNIT#4 m Q N# STORAGE I STORAGE I -STORAGE I STORAGE O C/) EQ. Ea. O 0 Ctf --- -—-—-—-—-—- TITLE: . ... • ... , ., ... : ..:. . . BASEMENT A �— -$3-------$3-- - A FLOOR PLAN I I I BUILDINGS 1&2 I I I I — ----- --�— I - DATE ISSUED: 09.17.2012 A9.1 REVISIONS: V-d 5'-5' 2'-4' 6' IZ'-la 33'-6' 6V-6' DRAWN BY: S.KHALIL 3 DRAWING NO.: - s BASEMENT FLOOR PLAN BUILDINGS 1&2 1 Scale:7/4"=1'-0" A O RS s j L r STAMP: �w w m 1 2 3 4 c 6 0 a U a 4'-9' a'-Ib 7-5' 4'-r B'd 4'-r 17-b' 3'-Ib Y3' B'-Itl a A3.1 A3.1 C3 Z A3.1 Aj lad PVC PRIV z C SCREEN = 1tld p U w PVC PRIVACY C R —SCREEN m o DEeK �B o § JJNE OF 'EB 3 SHALLOW SWED ROOF OVER �B DECK o b mREAR DECK DOORS - 10' 5'd D c d lad � - c ~ (���, D Z Lu Lu C OO - J W W C -- � - - - --- -- --- - C � A - STORAGE I A CI /PA Fm C CI J Y KITCHEN O - BATH O KITCHEN /�-f( W ITC„I., REF 14 A DyE„2. F q TPE'1" I, \ F� 7 PAvrav 'o PANTRY Q Lu O �•' A 3'{' ' DINING AREA �'{' REF iv 0 Q KITCHEN _� m _ -"J TwE•z &A Q Lo 4d ® 4d aEAR A ELEL.PANEL A Z O1 UNIT'Y,BUIIDING TUB/ C (n Z d J Lu Y BATH A n Y BATH 5EN50RY II'PAIRFD UNIT _ LINEN a O 5NWR _TH N J_ g ELEC,�/P - O A A a ,,,IU� O O O 0 A Y-v2' S'-T' b'-II�q UNIT��2�' S'_ 4-'2' = LL O PM1EL A b W p{ - D A E A DINING AREA _ 4 Z W U Z lC DINING AREA A STAIR p _ E� STORAGE b B I y 14 O 'm m O / B A E - - BEDROOM STORAGE ,jam O x''_ l u .9 V 111- ' IL •`------ LIVING NG ROOM ' 3'-Y T i Lu UNIT"l 3'48' -3'ge'- _ A UNIT'3" cf) C PROVIDE O m U) i0 D y ACCESS PANEL n A �_. a- *+ - •4• BENEATH STAIR ; O°G O CD oo' r__ UP STAIR UP i ou LIVING ROOM _ O O m STAIR LIVING ROOM d B -- ------ - ��� 3'd VC ------ - - - B TITLE: B B B B B COVERED 2'-1' PORC" n COVERED Y 00 g —`" j I FIRST FLOOR PLAN A — — — ———— — M A BUILDINGS 1&2 0 0 �0- c-ERED ov aEo �., b'-8' q'd �'-b" v I I B C I I I P0— I 1 D� A3., A3.1 13 — 94i DATE ISSUED: R '-1 2'-4' 7-b' L OTE: REVISIONS: o D ALL INTERIOR DIMENSIONS FROM A3.1 AB, FACE OF STUD TO FACE OF STUD V-b' 3'-11i' 4'-w 4Iz' r-V 742' 3'�Z' 4-10, 1014 S'd 5'4z' 4W 3' ' V V • REFER TO SHEET A6.2 FOR ENLARGED STAIR PLANS t DETAILS y Ib'd 3V-6- Ib'd • REFER TO SHEET A7.1 FOR KITCHEN TYPES ER TO SHEET A7.2 FOR 3 BATHROOM TYPES t ELEVATIONS S.KHALIL 1 2 3 4 REFER TO SHEET A9.1 FOR TYPICAL DRAWN Bv: ELEVATION DETAILS FOR STORAGE i FIRST FLOOR GRO55 AREA- 1 56150 GSF PANTRY, LINEN CLOSET 4 CLOSET SHELVING (EXCLUSIVE OF PORCHES t DECKS) DRAW NG NO.: NOTE: FIRST FLOOR PLAN BUILDINGS 1&2 UNIT 'z" IN BUILDING 'I' -ONLY' U BE IT , DESIGNATED 'SENSORY IMPAIRED' UNIT. 1 scDe:1/4•=I�Q SENSORY IMPAIRED PROVISIONS PER A] 1 MAAB/AOA REQUIRED. I DOES QUIRE 5EN50RY IMPAIRE D PROVISIONS. L'� r STAMP: w Q C O U U z � U 1 I6'O' a 6'- 4 3'-r2' 044' 4'-7' &-0' V-7' 12'-6' 3'-Itl 2' b'-�' ��_ �g W A3.1 A3.1 A3.1 A3.1 '■� ou �B B B B O Z F— am W W G B O W STORAGE/PANTRY V__ O TT 2'-7' ° REF O ?. 12' ' T J C T- OLl£FOR BOILER CHASE FOR BOILER * W O Q M1 FLUE 4 VENT A 14 T i RAZE<VENT tr \ r r; A , BEDROOM#2 W 0 A BEDROOM#2 0 i DINING AREA A 13 O Q ~ U;§ f,l KITCHEN Y �_ - ;F - Q •i YJ iVPE'Y O - w ��II�� B ACCESS HATCH ABOVE. 19 A ' ACCESS HATCH ABOVE, B Z LJ BE DETAIL VA53 11 i ELEC.PANEL 'U 11 SEE DETAIL 2VA63 F H - LINEN yr A tC„` T- Q ----' fi 1y_�' _ r- T' ' 7-2' 6'-11y4' T-y'- ' 2 L A' BATH W — UNIT"4" ACCESS MTO11 i — A O W A3.1 A ABOVE,SEE i A' O BA7H A3.1 ~ U Z 7j iVPE•I• HALL LANDING A' Ta IYPE•I' a O ' DETAIL HALL a, z W C A ° D A ;W ``u A O '� r� m a Lu U C TTJgV 10 i O BEDROOM J TUB/ 04 Q O B Y w oB a t; u 14 w Y B C r I— F SPAR TUB" L U a LIVING ROOM O • (f� tff 32 A' Z W 11 A • 11 P-e' S'6' C7 Q Q A F32' A O m F—A HALF HALL a- �BEDROOM#1 , ��O BEDROOM#1 Oo A°O° 3'-2' A b —-—-— - -- ----- - -- - -- TITLE: SECOND FLOOR PLAN B 5 Al SOLAR SHADING 6 SOUTH ELEVATION,BUILDING'I' AI,a B G SOLAR SHADING 9 SOUTH ELEVATION,BUILDING'I' DATE ISSUED: 09.17. g NOTE: REVISIONS: DD1 ALL INTERIOR DIMENSIONS FROM 6'- 3'-� b�v' y'-I 3'_ b' 3'_ 6' FACE OF STUD TO FACE OF STUD 4 2 a dr2 �Z 15'-n' V-7' 4 a • REFER TO SWEET A6.2 FOR STAIRRE ERGED TO SHEET ATINFOR DKIITTCHEN TYPES t ELEVATIONS • REFER TO SWEET A7.2 FOR BATHROOM TYPES It ELEVATIONS s ELEVATFER ION DETAILS FOR STORO SWEET Aq.1 FOR AGEL DRAWN BY: S.KF ALIL 4 PANTRY, LINEN CLOSET t CLOSET SHELVING DRAWING NO.: e SECOND FLOOR PLAN BUILDINGS 1&2 Spoe I,A -0. A 1 . 2 o� �e L J , r STAMP: Q Q Q c I I I 4 w LL �z — --------- -—-—- — la- ' q'_3' — -- ------ — ui I I I I z~ " #' 9'-VIr Z w o I e I c pv w� i A3.� i A3.1 4'-V HEIGHT CEDAR FENCE 0 m Q o EDGE OF AREAWAY,TYPICAL 3 a r TRENCH DRAIN,SEE a C, OPAL SHEET 5 OF 5 B o _ 4'-0. bi CQICRETE PAD p - - D ZERO STEP ENTRY 8 � z W W C - - -—-------- -------- --- -- C W fbl-DING CQINiQt ��� FgDING NT O Cn MECHANICAL ROOM a MECHANICAL ROOM a W O UNITS 1&4 D D WASH DRYER WASHER DRYER & g UNITS 2&3 v' COMMUNITY LAUNDRY I ' D Q F O 222'-d I'-+2' 14'-IOY4' : Q Q Lo D — ---- -1-----------� ---------- — z c� w FULL HEIGHT CHAIN ie ofN J O I 4'd D L PARTITIONS I O D p 0 Q > § weal G b BASEMENT . �? = LL- O Lv !C I I FULL HEIGHT CHAIN FLU ION PARTITS W/ ' '91 ' I T-0'WIDE I ' SH z W U z LOCKABLE GATES co Q 'Lu T-6 IV-so14'_p 15' N Lu W Q Q UNIT#1 , UNIT#2 Y' UNIT#3 UNIT#4 [� F— STORAGE I STORAGE I STORAGE STORAGE O C� EQ. EQ. O 0 c TITLE: BASEMENT ... ...'. :'.. r; .. ... A - —�— —E$-------$3-- - A FLOOR PLAN I I I BUILDING 3 C: ------------------- - I I I V-0' 5'-5' V-4' 6'-2' V-6' 9'-5' 9'-5' 7-6' 12'-10' DATE ISSUED: 09.17.2012 REVISIONS: I6'-0 3V-6' IV-& 6'-o i Y 9 DRAWN BY: S.KHALIL 3 �p BASEMENT FLOOR PLAN BUILDINGS 3 DRAWING NO.: Al . 3 L } y STAMP: 19 N w 1 2 3 4 a C Ib'd 0-0 16'_a Z 4'-9' B'-10' 7-5' 4'-7' V-0' 4'-4' O'-9' V-la 2'-5' W-la 4'-9' LL D D nn51 z A3.1 A3.1 lY— B c n A3.1 A3.1 J W Q� a d PRIVACr z H- N S SCREEN Ia-a o� PRIVACY m p FR. .-LD I OF SHALLOW SHED ROOF OVER B10 DECK b REAR DECK DOORS �B a c la-0' la-0' BASEMENT D z F— D ACCESS "� w w B ` -- -� --- - --0 C } C aLu ClO a y �� q O CI O O B WPSHER DRYER --71 CI A L J ` Y ii KITCHEN -BATH KITCHEN ; O Q NPE"I" mE i� T{ PANTRY / 14 TYPE"3" PANTRY REF w O * Rff qj• i KITCHEN i b DINING AREA i 9s' Q Q Q c td 4'4 r G -'ya sy p4 E�CEC.PANEL/i A5.3 PI `-' -6 Lu YzBAH OVEN Z_ a Lv N - J Yx BATH � _ B ELEC.PAN iO O �____� A A / �, ,,I� O 0 9'- A 5'_r 6' ' B 5'-r A -PANEL a"%'2� A O O O W A3.1 , _ UNIT"2" - A3.1 = I— _ DINING AREA a E LANDING HANDICAPPED A DINING AREA - z w U Z ACCESSIBLE gym( 0 W ' STORAGE - g' UNIT �.BEDROOM i STORAGE 1 O Q O A f __ LIVING ROOM a u -- ? A Ip_,I� B O L� II'-rl' V-p ro Y a ��~ V-2' vY' �W C lJ O i UNIT"I 3''iVq' _y�_4..- II'-3T�' 7-I' / �\°II'-B' "' UNIT"3" f.JO O m Q -P u PROVIDE ' UP TO STAIR ;r_ �__ UMT '4' ® ACCESS p________ ____ <. R BENEATH S?AIR o E O ems^U ROf - o UP STAIR O 2'-I' O A fi STAIR UP LIVING ROOM �/y�) LIVING ROOM 3'4 _ U TITLE: B 7 I' B B h N O covEaED B 7-I' w�o � I � PaicH � � ,�, . p u _ °O S C RED 9 U - re- �o I I Y I Q '" FIRST FLOOR PLAN _ I-----————_— --_———_——-- _—O BUILDINGS 3 A DI 3 B O B J-R I comet I i I f-q CONCRETE i P H i DATE ISSUED: T 2'-4' 7-6' IT-la NOTE; REVISIONS: ,V • ALL INTERIOR DIMENSIONS FROM - V-IV' 4"V 5' r-0, 6'_II?' 3'- 4,_3, II,_9, 5'-O' 5'-'�2' q'-0• 3'- y-0• 7-6' FACE OF STUD TO FACE OF STUD 16'd 6' Ib'-a ENLARGED TAR PLANSOR4 DETAILS 6 y '�,• REFER TO SHEET A7.1 FOR KITCHEN REFER TO S EETOA7.2 FOR OBATHROIX9 TYPES 4 ELEVATIONS 4 . REFER TO SHEET A9.I FOR TYPICAL DRAWN BY: S.KHAUL ELEVATION DETAILS FOR STORAGE PANTRY, LINEN CLOSET 4 CLOSET i SHELVING g' DRAWING NO.: FIRST FLOOR PLAN-BUILDINGS 3 AIA q. 1 scDe:v4•=rar .R �e L ' r STAMP: P i c Q c 1?1? O =� U U z 5 a o 1 T 3 4 zw <s - = w Ib'-0' 33'_6• 164V m� y co 3'- ' 0-4 1'-T V-0' V-0 17-9' V-Kr "4'4' 3'-x2' V44 \B � B %0 D A3.1 C p SOLAR SHADING B �B 50M ELEVATION CIE BUILDING'3• r__ ________ i B �-------- ----- B C B - --- -------- Z _ —_—_—,V_—_—_ _ STORAGE/ 2T CL N 2'-T REF O .ti B PANTRY A FLUE I FOR VENT LER R CHASE FOR BOILERIT A W O FLUE 4 VINT A IA BATH b, > A BEDROOM y ' TYPEs5 o BEDROOM O W = Q KITCHEN 5' DINING AREA 'Z? ° IB ZD Q U i4 .V IYPE'3• - - O y J 5 F s �I� L B 5EE5EE�NL VA553w II ° ELW.PANEL o o II SEE DETAIL�� g Z (D ry - r----, A TUB/SHWR m A _ I Q O � Q > A T-�• A' UNIT"W" - -i BATH A = = W BATH HALL A3.1 f— _ F— A3.1 - accEss Hara' — I / \\ I ?a TYPE"1' - 41 TYPE"Is - ' r4 DI b O a D�A53�/�*\\i O b b Z W U Z c - g C 4 � J Q W O C TUB/ �I ilg/ Q U HWR 5 w w s F B yI C F - TQ LMNG ROOM T- cn Lu B�•- I'•8' - 'S II A C V II W BEDROOM E m Q A° O A 1WF WALL ° 9i A' 0 o - BEDROOM O BEDROOM E _ o U 14 ° 3'M - Ba-- - _- --- - --- - -- ------- - - --{µ 1 TITLE: B i N _ o o O _ SECOND FLOOR ° PLAN �- BUILDINGS 3 g B B B 5 5 AI.b AI.b g C A3.1 A3.1 DATE ISSUED: a 09.17.2012 9'-412' 3'-V2' I6'-0• 51-0• 6'-`y' 3'- ' 6'-SV' NOTE: REVISIONS: • ALL INTERIOR DIMENSIONS FROM 161-V 33'-6' Ib'-0 FACE OF STUD TO FACE OF STUD • REFER TO SHEET A6.2 FOR ENLARGED STAIR PLANS 4 DETAILS 651_6\ • REFER TO SHEET A7.1 FOR KITCHEN TYPES It NS D REFER TO 5 EETOA7.2 FOR D n3.i BATHROOM TYPES 4 ELEVATIONS REFER TO SHEET A9.1 FOR TYPICAL DRAWN BY: S.KHALIL ELEVATION DETAILS FOR STORAGE SECOND FLOOR GROSS AREA = I 150 G5F SHELVING LINEN CLOSET It CLOSET �4 DRAWING NO.: SECOND FLOOR PLAN BUILDINGS 3 A] . 5 L e's Barnstable, GENERAL NOTE5 : SOIL TE5T LOG5 : SYSTEM DE51GN CALCULATIONS : Plan Book48G Page 50 MA A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM TEST HOLE I . EL=GB± SEWAGE DE51GN FLOW: UNLESS H-20 COMPONENTS ARE USED. DEPTH FROM 501L SOIL SOIL 501L OTHER (6) 2 BEDROOM UNITS B.)THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN- SURFACE HORIZON TEXTURE COLOR MOTTLING (6) I BEDROOM UNITS 0ak5t LE55 CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING. (INCHES) (USDA) (MUNSELu 18 BEDROOMS TOTAL @ ! 10 GPD = !980 GPD REQUIRED C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL 0-7" 0/E 5ANDY LOAM I OYR 6 3' NONE LEACHING CAPACITY REQUIRED: Water/Electric Service UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 7-27' B ANDY LOAM !OYR 5 8 NONE 18 BEDROOMS(MAX.) @ ! I O GPD = !980 GPD REQUIRED 27-1 14" C! LOAMY AN NONE PRIMARY SEPTIC TANK CAPACITY REQUIRED: Water/Electric Service SEPTIC SYSTEM C O N ST f�U CT I O N NOTES• I !4-!63" C2 MEDIUM COARSE SAND !OYR 8 4 NONE DAILY FLOW= 1950 GPD @ 200% = 39GO GAL.REQUIRED / m TEST HOLE 2: EL=G7± PRIMARY SEPTIC TANK CAPACITY PROVIDED: G"Sewer line sleeved in a 20' DEPTH FROM SOIL 501L SOIL SOIL OTHER 4500 GALLON SEPTIC TANK section of 8"PVC pipe 6"Sewer line sleeved in a 20' e1 I.)ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, SURFACE HORIZON TEXTURE COLOR MOTTLING SECONDARY SEPTIC TANK CAPACITY REQUIRED: section of 8"PVC pipe TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH. (INCHES) (USDA) (MUNSE L) - - - - - - u 0-7" Ole SANDY LOAM !OYR 6 2 NONE DAILY FLOW= 1950 GPD @ 100% _ 1960 GAL. REQUIRED vo 2.)SEPTIC TANK(5), GREASE TRAP(5), D051NG CHAMBER(5)AND DISTRIBUTION 7-20" B 5ANDYLOAM !OYR 5/5 NONE PRIMARY SEPTIC TANK CAPACITY PROVIDED: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BOX(E5) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY 2500 GALLON SEPTIC TANK COMPACTED, OR ON A 6 INCH CRUSHED STONE BASE. (SEE D-BOX NOTE @ FLOW PROFILE) 20-79" C I LOAMY COARSE SAND I OYR GIG NONE 20 30%GRAVEL PERC 5G" LEACHING CAPACITY PROVIDED: - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 79-139" C2 EDI A E A D ! Y NONE 3.)SEPTIC TANK(5)SHALL MEET ASTM STANDARD C I !27-93 AND SHALL HAVE ARC 36HC CHAMBER- 132 UNITS IN FIELD CONFIGURATION (SEE SAS DETAIL) 10, 10, 10, 1 10' AT LEAST THREE 20"DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT- TEST HOLE 3: EL=G7± 132 X 5'(LAY-UP LENGTH)X 4.80'SF/LF= 31 G8 5F -�.- TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". DEPTH FROM 501L SOIL SOIL 501L OTHER Vt=3 1 68 5F X 0.74 GPD/5F=2344.3 GPD p NOT TO SCALE SURFACE HORIZON TEXTURE COLOR MOTTLING 2344 GPD>1950 GPD REQUIRED 4.)SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF G" (INCHES) (USDA) (lvl NOTE: A GARBAGE DISPOSAL 15 NOT PERMITTED WITH THIS DESIGN. PLAN BOOK 48G PAGE 58 ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE 0-7" O/E SANDY LOI I OYR G 3 NONE CERTIFICATE OF TITLE #i 485GO CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. INSTALL 7-29' B SANDY LOAM I OYR 5 8 NONE ONE(I)-4500 GALLON SEPTIC TANK(H-20) DEED BOOK 9481 .PAGE 201 5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST 29-84" C I I LOAMY COARSE SAND I CYR GIG NONE 5y.c gs zo o GE" ONE(1)- 2500 GALLON SEPTIC TANK(H-20) ASSESSORS' MAP 173 PARCEL 2G CONCRETE WATER TIGHT RI5ER5 OVER INLET AND OUTLET TEES TO WITHIN 6"OF 84-I 4G" C2 MEDIUM/COAR,51f SAND I Y NONE ONE-HUNDRED*THIRTY-TWO(132)-ARCH 36HC LEACHFIELD CHAMBERS FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT. TWENTY-TWO(22)-ARCH 36HC END CAPS �-� / F /F I F TEST HOLE M SOIL ELEVEN - I I ARCH 36HC SPLASH PADS 5 E WE I� /WATE K !ELECTRIC C K055 1 N G5 LEGEND 6.} PIPING SHALL CONSIST OF G"*4"SCHEDULE 40 PVC OR EQUIVALENT. PIPE DEPTH FROM SOIL SOIL 501E SOIL OTHER ONE(I)- I I OUTLET DISTRIBUTION BOX(H-20 Rated) � Y � ,/ SHALL BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN I%. SURFACE HORIZON TEXTURE COLOR MOTTLING FIVE(5)-24"CAST IRON FRAMES 4 COVERS BUILT UP TO GRADE(SEE FLOW PROFILE FOR DETAILS) 7.) D15TRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED)SHALL BE (INCHES) (USDA) (MUN5ELL) EIGHT(8)-CLEANOUT5(SEE PLAN VIEW AND CLEANOUT DETAIL FOR LOCATION AND INSTALLATION REQUIREMENTS) 3 EXISTING CONTOUR 4" DIAMETER SCHEDULE 40 PVC LAID AT 0.005 FT/FT. LINE SHALL BE CAPPED 0-7" O/E 5&NDY.-LQAM !OYR G13 NONE ELEVEN (I 1)-8"CAST IRON FRAMES AND COVERS BUILT UP TO GRADE(SEE FLOW PROFILE FOR DETAILS) NOT TO SCALE 32 PROPOSED CONTOUR AT END OR AS NOTED. 7-29" B SANDY LOAM I OYR 5 8 NONE 8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST 29-65" Cl GRAVELLY LOAMY AND I Y NONE x 2.34 EXISTING SPOT GRADE �COARSE SAND I OYR 8 4 NONE PERC 57" PROPOSED SPOT GRADE 2'BEFORE PITCHING TO SOIL ABSORPTION SYSTEM. WATER TEST D15TRIBUTION 65-120" C2 MEDIU BOX TO ASSURE EVEN DISTRIBUTION. TEST HOLE 5: EL=53± .' -W- PROPOSED WATER SERVICE LINE CO PARCEL -PE- PRIMARY ELECTRIC SERVICE 9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP Of G" MEASURED BELOW DEPTH FROM 501L 501L SOIL 501L OTHER O 72 THE OUTLET INVERT. SURFACE HORIZON TEXTURE COLOR MOTTLING 'n -5E- SECONDARY ELECTRIC SERVICE (INCHES) (USDA) (MUN5ELL) PROPOSED GAS SERVICE LINE 10.)VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET; 0-5" O/E LOAMY AND I OYR 3 4 NONE 0 26 P WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS, 5-24" B LOAMY SAND !OYR 5 8 NONE PARCEL 0 TEST HOLE/ BORING LOCATION TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; 0R WHEN PRESSURE DOSED. 24-1 44" C I FINE SAND I Y NONE � EL 7,� ST SEPTIC TANK 1 1.)SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM Of 9"OF TEST HOLE 6: EL=54± O �� 3 BENCHMARK: WO WATER GATE DI P I n 1 3.8 GLEAN MEDIUM SAND(EXCLUDING TO SO L) DEPTH FROM SOIL SOIL 501E SOIL OTHER -. `SO, / � BENCHMARK ELEVATION SAS SOIL ABSORPTION SYSTEM 2.) F1h1I ' GRADE `iAl€. B A P�,ax:N"(1P:' Of a6 t vwF; z.{. P Of AL,.. ;�:Y'N SURFACE HORIZON TEXTURE COLOR MOTTLING �G TO BE SET BY J.M. O'R ILLY Reserve RESERVED FOR FUTURE COMPONENTS, INCLUDING THE SEPTIC TANK, D15TRI15UTION BOX, D051NG CHAMBER (INCHES) (USDA) (MUNSELO oy� cq4;A550CIATff,5; INC. AND SOIL ABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER 0-5" O/E SANDY LOAM !OYR 6 3 NONE - PARCEL. 7G PRIOR O THE 5TART OF COL, UTILITY POLE OF 911. 5-25" BI 5AUDY LQAM. !OYR 5/5 NONE d� CONSTRUCTION ® CATCH BASIN 13.) FROM THE DATE OF INSTALLATION OF THE 501L ABSORPTION SYSTEM UNTIL 25-12 I" C I VE Y AMY AND I Y NONEVr� FIRE HYDRANT I RECEIPT OF A CERTIFICATE OF COMPLIANCE,THE PERIMETER OF THE SOIL A135ORP- DATE OF TESTING: 9/9/09 (TP PS 1-4)*8/1 7/1 2 (TP 95 5-6) ` °�, � � 3pq. ® WELL TION 5Y5TEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH PERCOLATION RATE: LESS THAN 2 MIN/INCH IN "C" LAYERS. \ AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM. WITNE55ED BY: KEITH E. FERNANDE5, PE,J.M. O'REILLY*ASSOCIATES, INC. ` (0) NYLOPLAST 8° INLINE DRAIN DONALD DESMARAIS,AGENT, BARNSTABLE HEALTH DEPARTMENT ■ CONCRETE BOUND, FOUND �Ir > "' X -X ' 14.)THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION 'i•, '-� +I BY AN AGENT OF THE BOARD QF HEALTH (0R THE DESIGNER IF SYSTEM RE- NO WATER ENCOUNTERED (��/ I •t f _ / \� TOP OF BANK THIS USE A LOADING RATE OF 0.74 GPD/5F FOR SIZING Of 501L ABSORPTION SYSTEM. c' Ir, (� '1• / X QUIRES A VARIANCE)AND MAY REQUIRE SUCH PERSON TO CERTIFY IN WRITING �C0 Cho O �-s--- LIMIT OF WORK/51LT FENCE THAT ALL WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE TER at MS OF THE �6 _ PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED. r 6� ❑ X FENCE HIGH GROUNDWATER LEVEL CALCULATIONS: EDGE Of CLEARING 15.) EFFLUENT FILTER SHALL BE A POLYLOC PL-525 EFFLUENT FILTER OR ENGINEER ' I 60 R, 01, APPROVED EQUIVALENT. INSTALLER SHALL MUST SUBMIT FILTER 5PECIFICATION5 Alr,: I I '4 ,�, '' _ S4 r \ r \ 0 ELECTRICAL TRAN5FORMER ODepth To Water Table (1 2-27-1 1). EL=40.G AND RECEIVE WRITTEN APPROVAL FROM ENGINEER IF 5UI35TITUTE FILTER IS TO BE Appropriate Index Well: 5DW-252 � WR !' I I PROPOSED 4'X 5'CONCRETE PAD ~�58 )p f USED.FILTER SHALL BE ACCE551BLE FROM BUILD-UP COVER. t '�P(66' Water Level Range Zone: C(3-4} I (MAX SLOPE OFF 1:50-AWAY FROM BUILDING) 5S i Deck WITH SCREW AP*CAST IRON COVER RAISED Current Depth To Water Level For Index Well(!2/1 1): 47.0' air' I SEE ARCHITECTURAL PLANS FOR DETAILS K De k r !6.) CLEAN-OUTS: A G"PVC CLEANOUT W SCR C ( p `Ir I RE5ERV O t TO GRADE)SHALL BE INSTALLED AT THE BUILDING FOUNDATION WHERE THE SEWER LINE Water Level Adjustment: 2.2 I I WITH G"ADS DURA5LOT DRAIN E 7� PROPOSED DRYWELL EXITS AT APPROX. 50'INTERVALS(SEE FLOW PROFILE PLAN VIEW FOR DETAILS# Estimated Depth To High Water: EL=42.8 / (3)TOTAL-(l)AT EACH BUILDING 1 °i " HC VAN t)tf1t / Iro I � Gb (See Sheet 5 of 5) LOCATIONS). �j�� r ��� LoI � NOhi De° / h 17.)501L REMOVAL: ALL TOP501L AND 5UB501L SHALL BE REMOVED FOR �� � r #1� L - - - - - -) M �s ;. S PARCEL 44 Q A DISTANCE OF 5' FROM THE 501L ABSORPTION SYSTEM DOWN TO THE CLEAN LIE /° 97b(� ��� SAND LAYER, LAYER C 1. AREA TO BE BACKFILLED WITH CLEAN "TITLE 5"SAND AND � j % 6� ° / o t De° / x h� COMPACTED TO MINIMIZE SETTLING. ilr, *' �S O 15.)WATER/ELECTRIC/5EWER CROSSING: WA5TELINE SHALL BE SLEEVED IN G"PVC PIPE AS '� / cv % `I I HC SHOWN ON PLAN VIEW AND ANYTIME IT CRO55E5 WITH A WATER/ELECT.RIC LINE OR I., � � 0 [� �1� s L w -��w- w w w �� tTp� PROPOSED SLEE VE WITHIN !O'OF A WATER/ELECTRIC LINE. - I ` ` /s o 0 0 0-0-0-0- -o-o- L1L I 7P 2 )�.t (SEE NOTE#18 AND DETAIL) 19.) INSTALLATION LOCATION OF PROP05ED VENT SHALL BE APPROVED BY THE HOUSING AUTHORITY. PROPOSED 8"WATER MAIN 20.)SEWER LINES FROM BUILDINGS 1, 2, �3 TO PROPOSED SEPTIC TANK SHALL BE G" 5CH. 40 PVC. LAID AT A MIN OF I%PITCH. ` t_ \ �, y� f k` L1 PROPOSED GAS 2 1.) DURING THE CONSTRUCTION OF THE SEPTIC SYSTEM,THE CONTRACTOR IS TO' - COORDINATE I � T � 0 0 0 / c72 LINE(SIZE TO COORDINATE WITH THE OWNERS SEPTIC MAINTENANCE COMPANY A5 CLARIFIED IN Ir I /S \ \ 0 0_ ,w -.w^w BE SPECIFIED BY �. SPECIFICATION SECTION 01.1 1 .00 1.BE. I I `� 6 w BER ENGINEERING) S D� DETAIL: _ _,` �� 56 f IrN ~-5 w M, 'T I I f� C3(iu( # 1 r E� 0 ° t�� Gave ry SCALE I"_ (0 I _ m Ac _ �. \w 0 1 PROPOSED VENT I ! 5 5 5 5 5 GO.26 5 5 5 5 5 5 3 `ti ec Deck / Pf FE rE e �e�\ 5 3 (SEE NOTE#19) ' //; f/ i ;. j:/ f iJ i / / ./ /. ,i ., f 9 �c o BLS /,, 58 6O '�/ f � / � WETLAND FLAGS: FLAGS b°ti ... �."\ xX $2. 98 �O / u' SET BY LEC ENVIRONMENTAL _/ �/I /�� � Utility Pole#1297-5 t� woe d CONSULTANTS, INC. PARCEL 6 x l r� n 2.88' oho �C2 3�j� �.�- '" PA 4 �a�Pare r >� RCEL 45 Vent 2.88' PLAN PO1/DS .� h j 2.88' 3 I.G8' ON Old �• ' -- �,. SCALE I "=40' Utility Pole#1207-3 y s 17 2.88' Irrte 50 /OOe f Loca '� �^ THE LAYOUT AND DIMENSIONS OF THE 2.8b ,✓ "` i - 08 - �. ,,,, �. PROPOSED BUILDINGS HAVE BEEN TAKEN „ d ,%j rx . y �^"u ',-r a '✓: '€� 'x., r Y�'r' � r e %,�A ^"�g �,f"w f "� ��-d ' "�=� 50' FROM THE AUTOCAD DRAWING ENTITLED ,•',F'/ �`- %-%a,. .. ,. .. , .. as.. - -02-20 1 2 6 "`" Buffer ACAD BHA CD 07 wg PROPOSED SOIL REMOVAL - / BY BROWN, LINDQUIST, FENUCCIO RABER ARCHITECTS INSPECTION PORT CLEAN-OUT DETAIL: FLOW PROFILE. (THREE TOTAL) NOT TO SCALE NOTTo.SCALE ELEVATION5 CRITICAL TO MEET I %O PITCH J.M. O'REILLY ASSOCIATES, INC. SHALL REQUIRE THE FOLLOWING IN5PECTIONS 24" DIAMETER CAST IRON COVERS DURING INSTALLATION OF THE PPOP05ED SEPTIC SYSTEM: CLEANOUT ADAPTER TOP OF FOUNDATION RAISED TO GRADE WITH THREADED PLUG I =66.0± USE EJIW LK! I OA (3)q"SCHEDULE 40 PVC ACCESS/INSPECTION I.) INSPECTION OF UNSUITABLE MATERIAL REMOVAL{IF ANY). PROPOSED FINISHED GRADE PORT TO INSTALLED TO GRADE W A PVC SCREW 2.) INSPECT AND ASBUILT ALL SEWER LINES,CLEANOUT5, �WATER/ELECTRIC/5EWER 2=G5.0± CAP AND EJIW#LA0910 4"PVC VENT CROSSING. e ,�g. 3=65.0± FRAME AND COVER CAP BY"SWEETAIR" 3.) VERIFICATION OF SOIL CONDITIONS AND/OR GROUNDWATER ELEVATION(IF EJIW#LAOe 10 (SEE NOTE#1 9) "` r^ Proposed EL= 55.0± Proposed EL=55.8± Proposed EL=55.2± Proposed EL= 55.0± 36'MIN NECE55ARY). FRAME AND COVER C3 TOP OF SLAG-, �� 4.) INSPECTION OF TITLE 5 FILL PRIOR TO BACKFILLING. 1=57.4± 'E; \ - \`��\ , *= 5.) FINAL INSPECTION OF ALL COMPONENTS PRIOR TO BACKFILLING. fff 2=56.4± G.) FINAL GRADING INSPECTION. STAGE COACH I\E5IDENCES 3=56.4± ;* 53.9± 53.5+ 3G" Proposed 5TO N E LE55 5Y5TEM 45° BEND SEE NOTE - (9 min-36 max) INSTALLER SHALL COORDINATE WITH BARNSTABLE HOUSING AUTHORITY FOR WHAT fi 52.00 INSPECTIONS NEED TO BE COMPLETED BY THEIR SEPTIC SYSTEM OPERATIONS AND do Barnstable Housing Authority, 14G South Street, Hyannl5, MA 02GO 1 MAINTENANCE VENDOR. 6 T-WYE CONNECTION INSTALL: 5 EWAG E D 15 P A Y T !-55.2± 52.49 101, 24" 52.24 � �� 1 ONE(!) -4500 GALLON SEPTIC TANK(H 20) ' . OS L 5 S E M DE51GN 2=54.2± I 0 24 5 i.96 I. 6 10.75" ONE(!) -2500 GALLON SEPTIC TANK(H-20) 3=54.2± 3 T 52.21 3° 51.93 5l.76 ONE-HUNDRED -TWO(I32)-ARCH 36HC LEACHFIELD CHAMBERS Jta�e Coach FOre5t Glen, Centerville, MA `SEE OUTLET TEE 67° 50.G7 TWENTY-TWO(22)-ARCH 36HC END CAPS NOTE 6'4" W/GA5 BAFFLE ELEVEN (! I)-ARCH 36HC SPLASH PADS TO 5EPTIC TANK #20 EFFLUENT FILTER 4-x4'-G°DEEP 50.67 ARCH 36HC LEACHING CHAMBERS(132) ONE(1)- I I OUTLET DISTRIBUTION BOX(H-20 Rated) / J.M. O REILLY & ASSOCIATES, INC. (SEE NOTE#1 5) CRUSHED GRAVEL 7.e'± FIVE(5)-24"CAST IRON FRAMES COVERS BUILT UP TO GRADE(SEE FLOW PROFILE FOR DETAILS) 6° SCH. 40 PVC SEWER LINE -/< 2-Y uFrs REUD 60.3± EIGHT(8)-CLEANOUT5(SEE PLAN VIEW AND CLEANOUT DETAIL FOR LOCATION AND INSTALLATION REQUIREMENTS) Professional Engineering �C sand Surveying Services k ELEVEN (I 1)-8"CAST IRON FRAMES AND COVERS BUILT UP TO GRADE(SEE FLOW PROFILE FOR DETAILS) I=20G'± PPIOP05ED I PRO I Longest Run USE(132)ARCH 36 HC SZ-EL-42.8± HIGH GROUNDWATER 4500 GALLON 3'± 1-3'± 201± LEACH CHAMBERS - 0 40 60 120 1573 Main Street - Route 6A 2=43'± 2500 GALLON PROPOSED 2 2 P.O. Box 1773 3=1501± SEPTIC TANK (STONELES55Y5TEM) SEPTIC TANK DB-I I -�-�- EL=40.6± OBSERVED GROUNDWATER 12/27/I I (508�86-6601 omee Brewster, MA 02631 (508)896-6602 Fax H-20 (SIDE VIEW) @ INTERMITTENT STREAM SCALE 1"=40' DATE: 5CALE: BY: CHECK: JOB NUMBER: H-20 D-BOX LEACHING CHAMBER (H-20) H-20 60.3'x 3 1 .7x 0.9' GAAAJobs\Barnstable Housing\Barnstable Housing Authority45 15-5tagecoach\201 2 CONSTRUCTION PHA5E\dw6j\4515.51te*5d5.dw6J E)/17/1 2 AS Noted KEF JMO JMO-45 1 5 '7