Loading...
HomeMy WebLinkAbout0086 KENNEDY CIRCLE - Health 86 Kennedy Circle `r n Hyannis P A = 268 054 d o p Q ECOJECH Environmental www.eco-tech.us THIS FORM IS A FACSIMILE OF THE STANDARD SEPTIC INSPECTION FORM ISSUED BY THE MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION(revised 6/15/2000) TITLE 5 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM PART A MAP Property Address: _ 86 Kennedy Circle CERTIFICATION PARCEL! d Owner's Name: Joseph nis LOT Guastella 1 Owner's Address: 86 Kennedy Circle Hyannis,MA 02601 Date of Inspection: July 16, 2003 Name of Inspector: (Please Print) David D. Coughanowr,R.S. Company Name: Eco-Tech Environmental JUL c� 1 2p03 Mailing Address: 43 Triangle Circle Sandwich,MA 02563 t�C1STABLE Telephone Number: (508)364-0894 TOWS OA H pF'?T. CERTIFICATION STATEMENT: r I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true,accurate and complete as of the time of the inspection.The inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. I am a DEP approved system inspector pursuant to section 15.340 of Title 5(310 CMR 15.000).The system: X Passes Conditionally Passes Needs Further Evaluation By the Local Approving Authority Fails Inspector's Signature FJ` - (:D• `'"'^ 2S Date: 3 )�' 1 *7 i 2003 The System Inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection.If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the DEP.The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving authority NOTES AND COMMENTS Inspector's Note—> A septic system is deemed to pass this Real Estate Transfer Inspection if it does not trigger any of the failure criteria listed below. The septic system has been evaluated according to the conditions observed on the day it was inspected. No estimate or guarantee of system longevity is made or implied by a passing determination. ****This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. Title 5 Inspection Form 6/15/2000 page 1 Page 2 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16, 2003 INSPECTION SUMMARY: Check A,B,C,D or E/ALWAYS complete all of section D: A] System Passes: X I have not found any information which indicates that any of the failure criteria described in 310 CMR 5.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. COMMENTS: B] System Conditionally Passes: One or more system components as described in the"Conditional Pass" section need to be replaced or repaired.The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass. Answer yes,no, or not determined(Y,N,or ND). in the_for the following statements.If"not determined"please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not),is structurally unsound,exhibits substantial infiltration or exfiltration, or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND explain: Observation of sewage backup or breakout or high static water level in the distribution box is due to broken or obstructed pipe(s)or due to a broken,settled or uneven distribution box. The system will pass inspection if(with approval of Board of Health). broken pipe(s)are replaced obstruction is removed distribution box is leveled or replaced. ND explain The system required pumping more than four times a year due to broken or obstructed pipe(s).The system will pass inspection if(with approval of the Board of Health): broken pipe(s)are replaced obstruction is removed ND explain 2 Page 3 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 C) Further Evaluation is Required by the Board of Health: Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health,safety and environment. 1 System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health,safety and the environment: Cesspool or privy is within 50 feet of a surface water Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh 2) System will fail unless the Board of Health(and public water supplier,if any)determines that the system is functioning in a manner that protects the public health,safety,and environment . The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well".Method used to determine distance "This system passes if the well water analysis,performed by a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form 3) OTHER 3 Page 4 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART A CERTIFICATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 D) System Failure Criteria applicable to all systems: You must indicate either"yes"or"no"to each of the following for all inspections: I have determined that one or more of the following failure conditions exist as described in 310 CMR 15.303. The basis for this determination is identified below. The Board of Health should be contacted to determine what will be necessary to correct the failure. yes no X Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool. X Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool. X Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool. X Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow.. X Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).Number of times pumped X Any portion of the SAS,cesspool or privy is below high groundwater elevation. X Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. X Any portion of a cesspool or privy is within a Zone 1 of a public well X Any portion of a cesspool or privy is within 50 feet of a private water supply well X Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis.(This system passes if the well water analysis, performed by a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form) No (Yes/No)The system fails.I have determined that one or more of the above failure criteria exist as described in 310 CMR 1515.303,therefore, the system fails.The system owner should contact the Board of Health to determine what will be necessary to correct the failure. E)Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd You must indicate either"yes"or"no"to each of the following: (The following criteria apply to large systems in addition to the criteria above) yes no the system is within 400 feet of a surface drinking water supply the system is within 200 feet of a tributary to a surface drinking water supply the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area-IWPA)or a mapped Zone II of a public water supply well. If you have answered"yes" to any question in Section E the system is considered a significant threat,or answered "yes" in section D above the large system has failed.The owner or operator of any large system considered a significant threat under section E or failed under section D shall upgrade the system in accordance with 310 CMR 15.304.The system owner should contact the appropriate regional office of the Department. 4 1 Page 5 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 Check if the following have been done: You must indicate either"Yes"or"No"as to each of the following: Yes No X _ Pumping information was provided by the owner,occupant or Board of Health. X Were any of the system components pumped out in the last two weeks? X _ Has the system received normal flows in the previous two week period? X Have large volumes of water been introduced to the system recently or as part of this inspection? n/a _ Were as built plans of the system obtained and examined?(If they were not available as N/A) X _ Was the facility or dwelling inspected for signs of sewage back-up? X Was the site inspected for signs of breakout? X _ Were all system components,excluding the SAS. located on site? n/a _ Were the septic tank manholes uncovered,opened,and the interior of the septic tank inspected for the condition of the baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum.? X _ Was the facility owner(and occupants,if different from owner) provided with information on the proper maintenance of subsurface disposal systems? For information on the proper maintenance of subsurface disposal systems please go to: WWW.ECO-TECH.US The size and location of the Soil Absorption System(SAS)on the site has been determined based on: X Existing information. For example,Plan at the Board of Health. X _ Determined in the field(if any of the failure criteria related to part is at issue,approximation of distance is unacceptable) [310 CMR 15.302(3)(b)] 5 Page 6 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 FLOW CONDITIONS RESIDENTIAL Number of bedrooms(design): n/a Number of bedrooms(actual): 3 DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): n/a—No plan on file at Health Dept Number of current residents 2 Does the residence have a garbage grinder(yes or no): no Is laundry on a separate sewage system(yes or no): no :(If yes, separate inspection required) Laundry system inspected (yes or no): n/a Seasonal use(yes or no):yes Water meter readings,if available(last two year's usage(gpd): 91 gpd Sump Pump(yes or no): no Last date of occupancy: current C OMMERCL4 L/INDU S TRIAL: Type of establishment: Design flow(based on 310 CMR 15.203):: gpd Basis of design flow(seats/persons/sqft/etc.): Grease trap present: (yes or no)_ Industrial waste holding tank present: (yes or no): Non-sanitary waste discharged to the Title 5 system: (yes or no). Water meter readings,if available: Last date of occupancy/use:_ OTHER: (Describe): GENERAL INFORMATION PUMPING RECORDS Source of information: System not Dumped in recent past(Owner) Was system pumped as part of the inspection: (yes or no) No If yes,volume pumped: gallons--How was quantity pumped determined? Reason for pumping: TYPE OF SYSTEM: Septic tank,distribution box, soil absorption system X Single cesspool X Overflow cesspool Privy Shared system(yes or no)(if yes,attach previous inspection records,if any) Innovative/Alternate technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) Tight Tank Attach a copy of the DEP approval Other(describe) APPROXIMATE AGE of all components,date installed(if known)and source of information: Age unknown—no records on file at Board of Health Were sewage odors detected when arriving at the site: (yes or no) no 6 Page 7 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 BUILDING SEWER_(Locate on site plan) Depth below grade: 1 ft Material of construction: X cast iron _40 PVC_other(explain) Distance from private water supply well or suction line 20+ Comments: (on condition of joints,venting,evidence of leakage,etc.) Sewer is vented through roof and appears structurally sound with no evidence of leakage or backup into dwelling SEPTIC TANK: none (locate on site plan) Depth below grade: Material of construction:_concrete_metal_fiberglass_polyethylene _other(explain) If tank is metal,list age_ Is age confirmed by Certificate of Compliance_(yes or no):_(attach a copy of certificate) Dimensions: Sludge depth: Distance from top of sludge to bottom of outlet tee or baffle: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle: How dimensions were determined: Comments: (on pumping recommendations,inlet and outlet tee or baffle condition, structural integrity,liquid levels as related to outlet invert,evidence of leakage,etc.): GREASE TRAP: none (locate on site plan) Depth below grade: Material of construction:_concrete_metal_fiberglass_polyethylene other(explain) Dimensions: Scum thickness: Distance from top of scum to top of outlet tee or baffle: Distance from bottom of scum to bottom of outlet tee or baffle:_ Date of last pumping: Comments: (on pumping recommendations,inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert,evidence of leakage,etc.): 7 Page 8 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16, 2003 TIGHT OR HOLDING TANK: none (Tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction:_concrete_metal _fiberglass_polyethylene_other(explain) Dimensions: Capacity: gallons Design flow:_gallons/day Alarm present(yes or no):_ Alarm level:_ Alarm in working order(yes or no):_ Date of last pumping: Comments:(condition of inlet tee,condition of alarm and float switches,etc.) DISTRIBUTION BOX: none (if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: Comments:(note if box is level and distribution to outlets is equal,any evidence of solids carryover,any evidence of leakage into or out of box,etc.) PUMP CHAMBER: none (locate on site plan) Pumps in working order: (yes or no) Alarms in working order: (yes or no) Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): 8 Page 9 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 SOIL ABSORPTION SYSTEM(SAS): X (locate on site plan;excavation not required) If SAS not located,explain why: Type: _leaching pits,number _leaching chambers,number _leaching galleries,number _leaching trenches,number,length _leaching fields,number,dimensions X overflow cesspool, number 1 —innovative/alternate system Type/name of Technology Comments: (note condition of soil, signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.) Soils above overflow cesspool appeared unsaturated.No evidence of surface ponding,breakout,lush vegetation, or other evidence of hydraulic failure was observed. Precast pit was dry. CESSPOOLS: X (cesspool must be pumped at time of inspection)(locate on site plan) Number and configuration: 1 primary,I overflow(see above) Depth-top of liquid to inlet invert: 1.5 ft+- Depth of solids layer: 6 in Depth of scum layer: 2 in Dimensions of cesspool: 6 ft x 6 ft precast Materials of construction: concrete Indication of groundwater inflow(yes or no): no Comments: (note condition of soil, signs of hydraulic failure,level of ponding,condition of vegetation, etc.): No evidence of surface ponding,breakout wet soils,lush vegetation or other evidence of hydraulic failure was observed.Primarypool contained 38 inches of effluent.Outlet pipe was fitted with tee. Overflow cesspool was dry and so pumping was deemed unnecessary .Both pits appeared in good structural condition.Pimping n�quired at this time,but maintenance pumping is recommended every 2 years. PRIVY:none (locate on site plan) Materials of construction: Dimensions:_ Depth of solids: Comments(note condition of soil, signs of hydraulic failure,level of ponding,condition of vegetation, etc.): 9 Page 10 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16,2003 SKETCH OF SEWAGE DISPOSAL SYSTEM: Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks.Locate all wells within 100'(Locate where public water supply enters the building) PRIMARY CESSPOOL OVERFLOW O O CESSPOOL 2 B LOCATIONS EXISTING A A B DWELLING 1 30.5 f t 23 f t # 86 2 16.5 ft 34 ft J ZCk J W H S 3I KENNEDY CIRCLE NOT TO SCALE 10 I w i l Page 11 of 11 OFFICIAL INSPECTION FORM_NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: 86 Kennedy Circle Hyannis Owner: Joseph Guastella Date of Inspection: July 16, 2003 SITE EXAM Slope Surface water Check Cellar Shallow wells Estimated Depth to ground water: 25+ feet Please indicate(check)all methods used to determine high ground water elevation: Obtained from system design plans on record-If checked. date of design plan reviewed Observed Site(abutting property/observation hole within 150 feet of SAS) Checked with local Board of health-explain: _ Checked local excavators,installers-attach documentation) X Accessed USGS database You must describe how you established the high ground water elevation. Town of Barnstable GIS Department records indicate that the groundwater table lies over 25 feet below the surface of the lot. 11