HomeMy WebLinkAbout0046 QUISSET ROAD - Health 46 QUISSET ROAD,HYANNIS
A= 250 129
i
i
9;!
Commonwealth of Massachusetts
Executive Office of Environmental Affairs
Dept. of Environmental Protection
rad
One winter Street' Septic Boston,Ma. 02108 .John Septi
D.L.P. Title V c Inspector
kir P.O. Box 2119
Teaticket, MA 02536
WILLIAM F.WELD (508)564-6813
Governor % 3
ARGEO PAUL CELLUCCI
Lt.Governor 1
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM ?"
PART A I�
,,��II e
CERTIFICATION
Property Address: 46 Qulsset Rd.Ceakw le�K63 Address of Owner: �y�Ty99 a
Date of Inspection: 5113198 (If different)
Name of Inspector: John Graci Mrs.Eisenberg
I am a DEP approved system inspector pursuant to Section 15.340 of Title%(310 CMR 15.000)
Company Name,Address and Telephone Number: elf
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate
and complete as of the time of inspection. The inspection was performed based on my training and experience in the proper function and
maintenance of on-site sewage disposal systems. The system:
x Passes This Inspection Is based on criteria dented In Title V
Conditional) Passes code 310 CMR 16203.My findings are of how the System Is
Y performing at the time of the Inspection.My Inspection does
_ Needs Fu h Evaluation By the Local Approving Authority not lmpty any warranty or guarantee ofthe longevity ofthe
Fails septic system and any of Its components useful life.
Inspector's Signature: Date: 5113198
The System Inspector shall s mit a copy of this inspection report to the Approving Authority within thirty(30)days of completing this
inspections. If the system is a shared system or has a design flow of 10,000 gpd or greater,the inspector and the system owner shall submit
the report to the appropriate regional office of the Department of Environmental Protection.
The original should be sent to the system owner and copies sent to the buyer,if applicable and the approving authority.
INSPECTION SUMMARY:
Check A, B,C,or D:
A] SYSTEM PASSES:
x I have not found any information which indicates that the system violates any of the failure criteria
defined as in 310 CMR 15.303. Any failure criteria not evaluated are indicated below.
COMMENTS:
B] SYSTEM CONDITIONALLY PASSES:
One or more system components need to be replaced or repaired. The system,upon completion
of the replacement or repair,passes inspection.
Indicate yes,no, or not determined(Y, N,or ND). Describe basis of determination in all instances. If "not determined",explain why not.
The septic tank is metal, unless the owner or operator has provided the system inspector with a copy of a Certificate of
— CoMpliance(attached)indicating that the tank was installed within twenty(20)years prior to the date of the inspection;or
the septic tank,whether or not metal, is cracked, structurally unsound, shows substantial infiltration or exfiltration, or tank
failure is imminent.The system will pass inspection if the existing septic tank is replaced with a conforming septic tank
as approved by the Board of Health.
(revised 007197)
One Winter Street • Boston,Massachusetts 02108 • FAX(617)556A049 • Telephone(617)292-5500
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 40 Qulsset Rd.Centerville 02032
Owner: Mrs.Eisenberg
Date of Inspection:5113190
— Sew.acle backup or.breakout.or. hiah.static water level obser.ved.in.the distribution box is due to a broken,
or obstructed pipe(s)or due to broken,settled or uneven distribution box.The system will pass inspection,if
(with approval of the Board of Health). Describe observations:
broken pipe(s)are replaced
obstruction is removed
distribution box Is leveled or replaced
—The system required pumping more than four times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
C] FURTHER EVALUATION IS REQUIRED BY THE BOARD OF HEALTH:
Conditions exist which require further evaluation by the Board of Health in order to determine if the
system is failing to protect the public health, safety and the environment.
1) SYSTEM WILL PASS UNLESS BOARD OF HEALTH DETERMINES THAT THE SYSTEM IS
NOT FUNCTIONING IN A MANNER WHICH WILL PROTECT THE PUBLIC HEALTH AND
SAFETY AND THE ENVIRONMENT:
Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a,bordering vegetated wetland or a salt marsh.
2) SYSTEM WILL FAIL UNLESS THE BOARD OF HEALTH(AND PUBLIC WATER SUPPLIER,IF APPROPRIATE) DETERMINES
THAT THE SYSTEM IS FUNCTIONING IN A MANNER THAT PROTECT THE PUBLIC HEALTH AND SAFETY AND THE
ENVIRONMENT:
— The system has a septic tank and soil absorption system and is within 100 feet to a
surface of water supply or tributary to a surface water supply.
— The system has a septic tank and soil absorption system and is within a Zone 1 of a public watersupply well.
— The system has a septic tank and soil absorption system and is within 50 feet of a private water supply well.
— The system has a septic tank and soil absorption system and the SAS is less than 100 feet but 50 feet or more from a
private water supply well, unless a well water analysis for coliform bacteria and volatile organic compounds indicates that
the well Is free from pollution from that facility and the presense of ammonia nitrogen and nitrate nitrogen is equal to or
less than 5 ppm. Method usedto determine distance (approximation not valid)
3)Other
D] SYSTEM FAILS:
You must indicate either"Yes"or"No"as to each of the following:
I have determined that the system violates one or more of the following failure criteria as defined in
310 CMR 15.303. The basis for this determination is identified below. The Board of Health should be
contacted to determine what will be necessary to correct the failure.
Yes No
_ — Backup of sewage in facility or system component due to an overloaded or clogged SAS or
cesspool.
Discharge or ponding of effluent to the surface of the protlnd or surface waters due to en overloaded or cloU0er1
cesspool.
— SAS is in hydraulic failure.
(revised 01127)87)
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 46 Qu(ssetRd.Centerville 02632
Owner: Mrs.Eisenberg
Date of Inspection:5113199
D]SYSTEM FAILS(continued)
Yes No
Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
Liquid depth in cesspool is less than 6"below invert or available volume is less than 1/2 day flow.
Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).
Numbers of times pumped
Any portion of the Soil Absorption System,cesspool or privy is below the high groundwater elevation.
Any portion of a cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply.
Any portion of a cesspool or privy is within a Zone 1 of a public well.
Any portion of a cesspool or privy is within 50 feet of a private water supply well.
Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no
acceptable water quality analysis. If the well has been analyzed to be acceptable,attach copy of well water analysis for
coliform bacteria,volatile organic compounds,ammonia nitrogen and nitrate nitrogen.
E] LARGE SYSTEM FAILS:
You must indicate either"Yes"or"No"as to each of the following:
The following criteria apply to large systems in addition to the criteria:
The system serves a facility with a design flow of 10,000 gpd or greater(Large System)and the system is a significant threat to
public health and safety and the environment because one or more of the following conditions exist:
� Yes No
the system is within 400 feet of a surface drinking water supply
_ Y 9 PP Y
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area(IWPA)or a mapped Zone II of a
public water supply well)
The owner or operator of any such system shall bring the system and facility into full compliance with the groundwater treatment program
requirements of 314 CMR 5.00 and 6.00. Please consult the local regional office of the Department for further information.
(revised 04127)87)
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECLIST
Property Address: 46 Quisset Rd.Centerville 02632
Owner: Mrs.Eisenberg
Date of Inspection:5113199
Check if the following have been done:YOU must indicate either"Yes"or"No"as to each of the following:
_t_ — Pumping information was requested of the owner,occupant,and Board of Health.
x None of the system components have been pumped for at least two weeks and the and the system has been receiving normal
— flow rates during that period. Large volumes of water have not been Introduced Into the system recently or as part of this
inspection.
x As built plans have been obtained and examined. Note if they are not available with N/A.
x — The facility or dwelling was inspected for signs of sewage back-up.
x — The system does not receive non-sanitary or industrial waste flow.
-x_ — The site was inspected for signs of breakout.
x All system components, excluding the Soil Absorption System,have been located on the site.
x The septic tank manholes were uncovered, opened,and the interior of the septic tank was inspected
for condition of baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge,depth of scum.
x The size and location of the Soil.Absorption System on the site has been determined based on
— — The facility owner(and occupants, if different from owner)were provided with information on the proper maintenance of
Sub-Surface Disposal Systens.
x Existing information. Ex. Plan at B.O.H.
x Determined in the field(if any failure criteria related to Part C is at issue,approximation of distance is
— — unacceptable)[15.302(3)(b)]
(revived 04$27)97)
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 40 Quisset Rd.Centerville 02632
Owner: Mrs.Eisenberg
Date of Inspection:5173199
FLOW CONDITIONS
RESIDENTIAL:
Design flow: 3M g•p•d./bedroom for S.A.S.
Number of bedrooms: 3
Number of current residents: 2
Garbage grinder(yes or no): Yes
Laundry connected to system(yes or no): Yes
Seasonal use(yes or no): No
Water meter readings,if available:(last two(2)year usage(gpd):
rVa
Sump Pump(yes or no): No
Last date of occupancy: nla
COMMERCIAL/INDUSTRIAL:
Type of establishment: r0a
Design flow:o gallons/day
Grease trap present: (yes or no) No
Industrial Waste Holding Tank present:(yes or no) No
Non-sanitary waste discharged to the Title 5 system:(yes or no) No
Water meter readings,if available: nfa
Last date of occupancy: nra
OTHER:(Describe) roa
Last date of occupancy:
GENERAL INFORMATION
PUMPING RECORDS and source of information:
System was pumped two years ago.
System pumped as part of inspection:(yes or no)No
If yes,volume pumped:0 gallons
Reason for pumping: nla
TYPE OF SYSTEM
x Septic tank/distribution box/soil absorptions system
Single cesspool
Overflow cesspool
Privy
Shared system(yes or no) ( if yes,attach previous inspection records,if any)
I/A Technology etc.Copy of up to date contract?
Other:
APPROXIMATE AGE of all components,date Installed(if known)and source Information:
16 yem
Sewage odors detected when arriving at the site:(yes or no) No
I
(revised 04127)87)
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION (continued)
Property Address: 46 QuissetRd.Centerville 02632
Owner: Mrs.Eisenberg
Date of Inspection:5113199
SEPTIC TANK: x
(locate on site plan)
Depth below grade: 1'
Material of construction:x concreate_metal FRP_Polyethylene_other(explain)
If tank is metal, list age nia . Is age confirmed by Certificate of Compliance No (Yes/No)
Dimensions: t.e'6"H67^w4'lV
Sludge depth:3"
Distance from top of sludge to bottom of outlet tee or baffle: 24"
Scum thickness:3"
Distance from top of scum 10 top of outlet tee or baffle:6"
Distance form bottom of scum to bottom of outlet tee or baffle: 16"
How dimensions were determined: measured
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles, depth of liquid level in relation to outlet invert,structural integrity,
evidence of leakage,etc.)
Septic tank end ell components are structurally sound and IlNnctloning property.Recommend pumping every two years.
GREASE TRAP:_
(locate on site plan)
Depth below grade: We
Material of construction: _concrete_metal_FRP_Polyethylene_other(explain)
Dimensions: rda
Scum thickness:rda
Distance from top of scum to top of outlet tee or baffle:rda
Distance from bottom of scum to bottom of outlet tee or baffle:Na
Date of last pumping;,,
Comments:
(recommendation for pumping,condition of inlet and outlet tees or baffles, depth of liquid level in relation to outlet invert, structural integrity,
evidence of leakage,etc.)
rda
BUILDING SEWER:
(Locate on site plan)
Depth below grade: iv-
Material of construction:_cast iron_40 PVC_other(explain)
Distance from private water supply well or suction line—
Diameter: 4^
rwimments:(conditions of joints,venting,evidence of leakage,etc.)
ii
(revised 04127)97)
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 40 Qulsset Rd.Centerville 02032
Owner: ' Mrs.Eisenberg
Date of Inspection:5113199
TIGHT OR HOLDING TANK:
(locate on site plan)
Depth below grade: rya
Material of construction:_concrete_m eta l_FRP_Polyethylene_other(explain)
Dimensions: rda
Capacity: rVa gallons
Design flow: rda allons/day
Alarm level:-.Na j larm in working order?_Yes_No
Date of previous pumping:
Comments:
(condition of inlet tee,condition of alarm and float switches,etc.)
We
DISTRIBUTION BOX:
(locate on site plan)
Depth of liquid level above outlet invert: nla
Comments:
(note if level and distribution is equal,evidence of solids carryover,evidence of leakage into or out of box etc.)
ria
PUMP CHAMBER:
(locate on site plan)
Pumps in working order.(yes or no)No
Alarms in working order(yes or no)_va
Comments:
(note condition of pump chamber,condition of pumps and appurtenances,etc.)
rfa
(revleed 0427l97)
I
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 46 Qulsset Rd.Centerville 02632
Owner: Mrs.Elsenberg
Date of Inspection:51131911
SOIL ABSORPTION SYSTEM(SAS):x
(locate on site plan,If possible;excavation not required,but may be approximated by non-intrusive methods)
If not determined to be present,explain:
We
Type:
leaching pits,number: one 1000 gallon leeehpit
leaching chambers,number:We
leaching galleries,number: nla
leaching trenches,number,length: rda
leaching fields,number, dimensions:nla
overflow cesspool,number:We
Alternate system: nla Name of Technology:_rda
Comments:(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation,etc.)
Leach pit and all componarde are structurally found and Nncdonlnp properly.System never had more than 7 or water In It
CESSPOOLS:
(locate on site plan)
Number and configuration: nra
Depth-top of liquid to Inlet Invert: rk
Depth of solids layer: nk
Depth of scum layer: nla
Dimensions of cesspool: nla
Materials of construction: nle
Indication of groundwater: n►a
inflow(cesspool must be pumped as part of inspection)
nfa
Comments:(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation, etc.)
We
PRIVY:
(locate on site plan)
Materials of construction: Ns Dimensions: Na
Depth of solids: nla
Comments:(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation, etc.)
rya
(revised 04127197)
a
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
40 Qulsset Rd.Centerville 02632
Mrs.Eisenberg
5113198
SKETCH OF SEWAGE DISPOSAL SYSTEM:
include ties to at least two permanent references, landmarks or benchmarks
locate all wells within 100'(Locate where public water supply comes into house)
g�k
a
P
a
.AA ,7
(rnvl.•d04WNT) Page P of 20
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
46 Qulsset Rd.Centerville 02532
Mrs.Eisenberg
5113198
Depth of groundwater 12r
Please indicate all the methods used to determine High Groundwater Elevation:
Obtained from design plans on record.
Observation of Site(Abutting property,observation hole, basement sump etc.)
Determine it from local conditions
Check with local Board of Health
Check FEMA Maps
Check pumping records
Check local excavators, installers
X Use USGS Data
Describe in your own words how you established the High Groundwater Elevation.(MUST be completed)
USGS maps and charts
R
(revised MUST) rage IO of 10
P � P
CP
10
_ rI� _
P :l: !�
z Wo l!% t� s
A � s C'
s rw
rA
74
v v + N
� s �
N
W
F
..�.
�� � �- ��;
�� �. ��
;, -� --
I(
�� I
1
/.
1 /
�' y
I
I
i
" I
�a.� C�
�f� � � i
!d_ �� �\
q�,
0
� ��
i
h
"TOTAL PROPERTY SERVICES"
August 5, 1986
To Whom it May Concern:
The house on 46 Quissett Road in Centerville, is currently a two ~
bedroom, one and one half bath house with an attached garage.
Mr. Build Cape Cod Memode.lAnge. proposes to remodel the existing
garage. to a master bedroom and add.-.a shower to the existing one half bath
on the first story, turrC,,ng the hous,e ;J`,nto a three bedroom, two bath.
Sincerely,
�ard F. Hayes
�
Mr. Build Cape Cod Remodeling