HomeMy WebLinkAbout0104 SEAGATE LANE - Health 104 Seagate Lane
Hyannis
A=249 138
TOWN OF BRRNSTABI.E C-
LOCATION SEWAGE # C�rS�" Coto
'VILLAGEi � !'►J.� ASSESSOR'S MAP & LOT QY�
INSTALLER'S NAME&PHONE NO.
SEPTIC TANK CAPACITY
LEACHING FACILITY: (type) `C2 C (size) /Z ?X Z
NO. OF BEDROOMS
BUILDER OR OWNER " G"
PERMITDATE: d- COMPLIANCE`DATE: 2
Separation Distance Between the: t
Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility
t Z Feet
Private Water Supply Well and Leaching Facility (If any wells exist
on site or within 200 feet of leaching facility) . Feet .
Edge of Wetland and Leaching Facility(If any wetlands exist_ w'
within 300 feet of leaching facility) Feet
Furnished by
W �
ti
c '
UNITED STATES PQ$TAL.SRVLCE
ratm ass Mail
P 0S g tA'e&V64111d
USPS
. . .......... .......
0 Sender: Please print your name, address, and ZIP+4 in this box
PtfBLI.0 HEALT-f-I DIVISION
,OWN OF BARNSTABLE
200 N.IA.Rq STREET
HYAN N'.IS, MASSACHtJSETTS 02601
� . . �.
WIN
■ Complete items 1,2,and 3.Also complete A. Signature
item 4 if Restricted Delivery is desired. X ❑Agent
M Print your name and address on the reverse ❑Addressee
so that we can return the card to you. B. RC.j by(Printed Name) C. Date of Delivery ,I
is Attach this card to the back of the mailpiece,
or on the front if space permits. I I
D. Is delivery address different from item 1? ❑Yes I
1. Article Addressed to: If YES,�e ter delivery address below: ❑No I
I r ,, I
Mr Jong Ra i� !
200 Cove Way #1015
I
Quincy, MA 02169 Service Type
0 Certified Mail ❑Express Mail
❑Registered ❑ Return Receipt for Merchandise
❑ Insured Mail ❑C.O.D.
4. Restricted Delivery?(Extra Fee) ❑Yes
2. Article Number _
(Transfer from service labeq J In f=
PS Form 3811,August 2001 Domestic Return Receipt 102595-02-M-1540
MEMO
a
clD OFFICIAL USE
Postage $ A
C3 �\
Certified Fee
C3 �.� Postmar
C3 Return Receipt Fee Here N
(Endorsement Required) p�
Restricted Delivery Fee
O (Endorsement Required)
C3
T-q Total Postage&Fees
ru Sent To
o r
� Street,Mt.No-=------ -
--------•--•---/-•--'----------- ----------�---�----------
or PO Box No. a Q(f CO yG L.tJQ�tJ /(J/S
CiS........ 7
u,ae. oa�6 g
2131 NIF
f
Certified Mail Provides:
o A mailing receipt
o A unique identifier for your mailpiece
n A signature upon delivery
n A record of delivery kept by the Postal Service for two years
Important Reminders:
13 Certified Mail may ONLY be combined with First-Class Mail or Priority Mail.
13 Certified.Mail i not available for any class of international mail.
n NO INSURE i 6QPOVE9AC
gE IS PROVIDED with Certified Mail. For
valuables,'Fplease congider Iri4,ed or Registered Mail.
o For an additional fee„a Return Receipt may be requested to provide proof of
delivery.To obtain -.turn Receipt service,please complete and attach a Return
Receipt(PS F '11)to the article and add applicable postage to cover the
fee.Endorse piece 'Return Receipt Requested".To receive a fee waiver for
a duplicate re rn receipt,la USPS postmark on your Certified Mail receipt is
required. /
n For an add i Tonal tee delivery may be restricted to the addressee or
addressee's 1`Zt12ed agent/Advise the clerk or mark the mailpiece with the
endorsement'Restiicted Delivery".
o If a postmark on the Certified Mail receipt is desired,pplease present the arti-
cle at the post office for postmarking. If a postmark on the Certified Mail
receipt is not needed,detach and affix label with postage and mail.
IMPORTANT:Save this receipt,and present it when making an inquiry.
PS Form 3800,April 2002(Reverse), i < 102595-02-M-1133
- II
COMMONWEALTH OF MASSACHUSETTS
EXECUTIVE OFFICE OF ENVIRONMENTAL AFF RCS
1 �F�,� OF r�-lAf2INS 1MBl,E
d DEPARTMENT OF ENVIRONMENTAL PROTECTION
206 JAIN 10 PtI 1: 42
5�
e�
TITLE 5
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM FORM
PART A
CERTIFICATION
Property Address: 104 Seagate Lane
Hyannis MA 02601
Owner's Name: Jong Ra
Owner's Address: 200 Cove Way, unit 1015
Quincy MA 02169
Date of Inspection: December 8,2005 Job#05-359
Name of Inspector: PATRICK M.O'CONNELL
Company Name: SEPTIC INSPECTION SERVICES CO.
Mailing Address: 189 CAMMETT ROAD
MARSTONS MILLS MA 02648
Telephone Number: 508-428-1779
CERTIFICATION STATEMENT
I certify that I have personally inspected the sewage disposal system at this address and that the information reported
below is true,accurate and complete as,of the time of the inspection. The inspection was performed based on my
training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP
approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000). The system:
Passes
Conditionally Passes
Needs Further Evaluation hLLocal pprovi Authority
Inspector's Signature: V Date: 12/8/05
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or
DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000
gpd or greater,the inspector and the system owner shall submit the report to the appropriate regional office of the
DEP.The original should be sent to the system owner and copies sent to the buyer, if applicable,and the approving
authority.
Notes and Comments: Single Cesspool full to top and previously breaking out to surface.
****This report only describes conditions at the time of inspection and under the conditions of use at that
time.This inspection does not address how the system will perform in the future under the same or different
conditions of use.
Title 5 Inspection Form 6/15/2000 page 1
1
Page 2 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION (continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
Inspection Summary: Check A,B,C,D or E/ALWAYS complete all of Section D
A. System Passes:
I have not found any information which indicates that any of the failure criteria described in 310 CMR
15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below.
Comments:
B. System Conditionally Passes:
One or more system components as described in the"Conditional Pass"section need to be replaced or
repaired.The system,upon completion of the replacement or repair,as approved by the Board of Health,will pass.
Answer yes,no or not determined(Y,N,ND)in the for the following statements. If"not determined"please
explain.
The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is structurally
unsound,exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the
existing tank is replaced with a complying septic tank as approved by the Board of Health.
*A metal septic tank will pass inspection if it is structurally sound,not leaking and if a Certificate of Compliance
indicating that the tank is less than 20 years old is available.
ND explain:
Observation of sewage backup or break out or high static water level in the distribution box due to broken or
obstructed pipe(s)or due to a broken,settled or uneven distribution box. System will pass inspection if(with
approval of Board of Health):
broken pipe(s)are replaced
obstruction is removed
distribution box is leveled or replaced
ND explain:
The system required pumping more than 4 times a year due to broken or obstructed pipe(s).The system will
pass inspection if(with approval of the Board of Health):
broken pipe(s)are replaced
obstruction is removed
ND explain:
TitlA C incnnrtinn Fnrm lil ci�nnn 2
Page 3 of 11
OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 104 Seagate Lane,Hyannis
n Owner: Jong Ra
Date of Inspection: December 8,2005
C. Further Evaluation is Required by the Board of Health:
Conditions exist which require further evaluation by the Board of Health in order to determine if the system
is failing to protect public health,safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the
system is not functioning in a manner which will protect public health,safety and the environment:
_ Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
2. System will fail unless the Board of Health(and Public Water Supplier,if any)determines that the
system is functioning in a manner that protects the public health,safety and environment:
_ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a
surface water supply or tributary to a surface water supply.
_ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply.
_ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well.
_ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a
private water supply well". Method used to determine distance
"This system passes if the well water analysis,performed at a DEP certified laboratory, for coliform
bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and
the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other
failure criteria are triggered. A copy of the analysis must be attached to this form.
3. Other:
Tit1P i incnPrtinn 17^r All c/Innn 3
Page 4 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART A
CERTIFICATION(continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
D. System Failure Criteria applicable to all systems:
You must indicate"yes"or"no"to each of the following for all inspections:
Yes No
_X_ _ Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool
—X— _ Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or
clogged SAS or cesspool
—X— Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or
cesspool
_X_ _ Liquid depth in cesspool is less than 6"below invert or available volume is less than ''/z day flow
_X_ Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s).
Number of times pumped
_X_ Any portion of the SAS,cesspool or privy is below high ground water elevation.
—X— Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface
water supply.
X Any portion of a cesspool or privy is within a Zone 1 of a public well.
X Any portion of a cesspool or privy is within 50 feet of a private water supply well.
—X— Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water
supply well with no acceptable water quality analysis. (This system passes if the well water analysis,
performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds
indicates that the well is free from pollution from that facility and the presence of ammonia
nitrogen and nitrate nitrogen is equal to or less than 5 ppm,provided that no other failure criteria
are triggered.A copy of the analysis must be attached to this forma
_Yes_(Yes/No)The system fails. 1 have determined that one or more of the above failure criteria exist as
described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of
Health to determine what will be necessary to correct the failure.
E. Large Systems:
To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000
gpd•
You must indicate either"yes"or"no"to each of the following:
(The following criteria apply to large systems in addition to the criteria above)
yes no
_ the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area—IWPA)or a mapped
Zone II of a public water supply well
If you have answered"yes"to any question in Section E the system is considered a significant threat,or answered
"yes"in Section D above the large system has failed. The owner or operator of any large system considered a
significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR
15.304.The system owner should contact the appropriate regional office of the Department.
Titic C Tnenontinn Rnrm Ail;i)nnn 4
Page 5 of I I
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART B
CHECKLIST
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
Check if the following have been done. You must indicate"yes"or"no"as to each of the following:
Yes No
_X_ Pumping information was provided by the owner,occupant,or Board of Health
_ _X_ Were any of the system components pumped out in the previous two weeks
_X_ Has the system received normal flows in the previous two week period?
_ _X_ Have large volumes of water been introduced to the system recently or as part of this inspection?
_ _X_ Were as built plans of the system obtained and examined?(If they were not available note as N/A)
_X_ Was the facility or dwelling inspected for signs of sewage back up?
_X_ _ Was the site inspected for signs of break out?
_X_ _ Were all system components,excluding the SAS, located on site?
_X _ Were the septic tank manholes uncovered,opened,and the interior of the tank inspected for the
condition of the baffles or tees,material of construction,dimensions,depth of liquid, depth of sludge and depth of
scum?
_X _ Was the facility owner(and occupants if different from owner)provided with information on the proper
maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System(SAS)on the site has been determined based on:
Yes no
_X_ Existing information.For example,a plan at the Board of Health.
_X_ _ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of
distance is unacceptable)[310 CMR 15.302(3)(b)]
T41a G Tncnartinn t7nr Aii;iinon 5
Page 6 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
FLOW CONDITIONS
RESIDENTIAL
Number of bedrooms(design): unknown Number of bedrooms(actual): 3
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms):
Number of current residents:0
Does residence have a garbage grinder(yes or no): No
Is laundry on a separate sewage system(yes or no): No [if yes separate inspection required]
Laundry system inspected(yes or no):
Seasonal use:(yes or no): No
Water meter readings,if available(last 2 years usage(gpd)): Two years total: 190,500 gal.=260 gpd.
Sump pump(yes or no): No
Last date of occupancy: unknown
COMMERCIAL/INDUSTRIAL
Type of establishment:
Design flow(based on 310 CMR 15.203): gpd
Basis of design flow(seats/persons/sqft,etc.):
Grease trap present(yes or no):_
Industrial waste holding tank present(yes or no):
Non-sanitary waste discharged to the Title 5 system(yes or no):_
Water meter readings, if available:
Last date of occupancy/use:
OTHER(describe):
GENERAL INFORMATION
Pumping Records: none
Source of information:
Was system pumped as part of the inspection(yes or no): No
If yes,volume pumped:_gallons--How was quantity pumped determined?
Reason for pumping:
TYPE OF SYSTEM
_Septic tank,distribution box, soil absorption system
_X Single cesspool
_Overflow cesspool
Privy
_Shared system(yes or no)(if yes,attach previous inspection records, if any)
_Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be
obtained from system owner)
_Tight tank _Attach a copy of the DEP approval
_Other(describe):
Approximate age of all components,date installed(if known)and source of information:
unknown
Were sewage odors detected when arriving at the site(yes or no): No
Titles C T--t;n Pnr fn snnnn 6
Page 7 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
BUILDING SEWER: XX (locate on site plan)
Depth below grade: 1'
Materials of construction:_cast iron _X_40 PVC_other(explain):
Distance from private water supply well or suction line:
Comments(on condition of joints, venting,evidence of leakage,etc.):
SEPTIC TANK: None found (locate on site plan)
Depth below grade:
Material of construction: concrete_metal_fiberglass_polyethylene
_other(explain)
If tank is metal list age:_ Is age confirmed by a Certificate of Compliance(yes or no):_(attach a copy of
certificate)
Dimensions:
Sludge depth:
Distance from top of sludge to bottom of outlet tee or baffle:
Scum thickness:
Distance from top of scum to top of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle:
How were dimensions determined: STICK WITH HINGE FLAP.
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels
as related to outlet invert,evidence of leakage,etc.):
GREASE TRAP: No (locate on site plan)
Depth below grade:_
Material of construction:_concrete_metal_fiberglass__polyethylene_other
(explain):
Dimensions:
Scum thickness:
Distance from top of scum to top of outlet tee or baffle:
Distance from bottom of scum to bottom of outlet tee or baffle:
Date of last pumping:
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels
as related to outlet invert,evidence of leakage,etc.):
Tifla i Tncnartinn 17^r 411 v)nnn 7
Page 8 of 11
OFFICIAL INSPECTION FORM-NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
TIGHT or HOLDING TANK: No (tank must be pumped at time of inspection) (locate on site plan)
Depth below grade:
Material of construction: concrete metal fiberglass_polyethylene other(explain):
Dimensions:
Capacity: gallons
Design Flow: gallons/day
Alarm present(yes or no):
Alarm level: Alarm in working order(yes or no):
Date of last pumping:
Comments(condition of alarm and float switches,etc.):
DISTRIBUTION BOX: No (if present must be opened) (locate on site plan)
Depth of liquid level above outlet invert:
Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of
leakage into or out of box,etc.):
PUMP CHAMBER: No (locate on site plan)
Pumps in working order(yes or no):
Alarms in working order(yes or no):
Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.):
Titles C lncn Finn Fn—411;MAO 1 8
1
Page 9 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
SOIL ABSORPTION SYSTEM(SAS): No (locate on site plan,excavation not required)
If SAS not located explain why:
Type
leaching pits,number:
leaching chambers,number:
leaching galleries,number:
leaching trenches, number, length:
leaching fields,number,dimensions:
overflow cesspool,number:
innovative/alternative system Type/name of technology:
Comments(note condition of soil,signs of hydraulic failure, level of ponding,damp soil,condition of vegetation,
etc.):
CESSPOOLS: XX (cesspool must be pumped as part of inspection) (locate on site plan)
Number and configuration: One single
Depth—top of liquid to inlet invert: Over top
Depth of solids layer:
Depth of scum layer:
Dimensions of cesspool: 6x6+/-
Materials of construction: Block
Indication of groundwater inflow(yes or no):
Comments(note condition of soil,signs of hydraulic failure, level of ponding,condition of vegetation,etc.):
Liquid and solids level at top of structure with evidence of previous breakout to surface.Amount of
solids and other flushed materials indicates this is a cesspool.No other structures were located.
PRIVY: No (locate on site plan)
Materials of construction:
Dimensions:
Depth of solids:
Comments(note condition of soil,signs of hydraulic failure, level of ponding,condition of vegetation,etc.):
Titles S lncnartinn Rnr Ail annnn 9
Page 10 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
SKETCH OF SEWAGE DISPOSAL SYSTEM
Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or
benchmarks.Locate all wells within 100 feet. Locate where public water supply enters the building.
Seagate Lane
Water service
# 104
21
56
T41a incnartinn Anrm 4/1411nnn 10
Page 11 of 11
OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS
SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM
PART C
SYSTEM INFORMATION(continued)
Property Address: 104 Seagate Lane,Hyannis
Owner: Jong Ra
Date of Inspection: December 8,2005
SITE EXAM
Slope None
Surface water None
Check cellar Dry
Shallow wells None
Estimated depth to ground water
Please indicate(check)all methods used to determine the high ground water elevation:
Obtained from system design plans on record-If checked,date of design plan reviewed:
Observed site(abutting property/observation hole within 150 feet of SAS)
Checked with local Board of Health-explain:
Checked with local excavators, installers-(attach documentation)
Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
A perc test will be performed prior to repair to determine groundwater elevation.
Titlo i Tncnartinn Rnr Ail Vnnnn 11