HomeMy WebLinkAbout0068 WACHUSETT AVENUE - Health 68 Wachusett Av'e Hyannis Port A = 287 - 081 - 001 I� TOWN OF BARNSTABLE LOCATION SEWAGE# Ott- i l VILLAGE Wje ,— ASSESSOR'S MAP&PARCEL 7 INSTALLER'S NAME&PHONE NO. G 1 !;!3T.-7`f l-934"l SEPTIC TANK CAPACITY i - as .rao LS.a I LEACHING FACILITY:(type) (size) .J NO.OF BEDROOMS - OWNER PERMIT DATE: ,� i � COMPLIANCE DATE: Separation Distance Between the: _ _ Maximum Adjusted Groundwater Table to the Bottom of Leaching Facility A—S Feet Private Water Supply Well and Leaching Facility(If any wells exist on site or within 200 feet of leaching facility) Feet Edge of Wetland and Leaching Facility(If any wetlands exist within 300 feet of leaching facility) Feet FURNISHED BY .1�0�'✓ t !'iw++�-ihs a Al a � E D- 1 No. l �f Fee THE COMMONWEALTH OF MASSACHUSETTS Entered in computer: Yes ` PUBLIC HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS 2ppYication for Disposal *pstem Construction Permit Application for a Permit to Construct( ) Repair e-Y Upgrade( ) Abandon( ) Complete System ❑Individual Components Location Address or Lot No. AoeOwner's Name,Address,and Tel.No.Ste•S/6ZY. //( S 41e.,1/0 6,G A)0V i.d, IS OSf.w.Yla rr"SiM6610 Assessor's Map/Parcel J1 fj/-/ 05 0;)4S^S Installer's Name,Address,and Tel.No. 5''01f-J*/- 9359 Designer's Name,Address,and Tel.No. s'OS�•3CoR �040 kr6u Cons(-roc ion,�rvc F e•(316x 1)6) c7ou�»C'ce ,arc 'rar_,-Ons O� Type of Building: Dwelling No.of BedroomS614i 4 " tC VLot Size SOoo sq.ft. Garbage Grinder( ) Other Type of Building No.of Persons Showers( ) Cafeteria( ) Other Fixtures Design Flow(min.required) L4 4 O gpd Design flow provided gpd Plan Date Number of sheets " J Revision Date Title /,i-le S tea. &a o-t t tr ll Size of Septic Tank /J`'vc� tfa U Type of S.A.S. 3� l�2e; cS(��Q a, nt 33.S X 1-R°U Description of Soil Nature of Repairs or Alterations(Answer when applicable) Date last inspected: Agreement: The undersigned agrees to ensure the construction and maintena ce o e ore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental a and n o place the system in operation until a Certificate of Compliance has been issued by this Board of Health. Sign ,®~ _.Date Application Approved by Date l J� Application Disapproved b /� Date for the following reasons Permit No. zv I C ~' 1 Date Issued �<;a� •.� � �•�� ► sx;, �4 t ,.� to ; - �*. . a� •y,--�:fix C � � • No. ©I Ulrl� . Fee /'' ' p - Entered in computer: i/ .THE COMMONWEALTH OF MASSACHUSETTS �'� Yes PUBLIC`HEALTH DIVISION - TOWN OF BARNSTABLE, MASSACHUSETTS implication for Misposai 6pstem Construction Jermit Application for a Permit to Construct( ) Repair(-Nil Upgrade( ) Abandon( ) K]Complete System ❑Individual Components Location Address or Lot No.& Owner's Name,A dress,and Tel.No. I J�Ct au'1 i s 4 ✓d- Lcs /9 jam: Assessor's Map/Parcel Installer's Name,Address,.a d T 1.No. 5'Ofr 91,V- `"391i "'> Designer.'s Name,Address,and Tel No. ?QV' /3a�Iola{ � c:ans{-rvc �on,�,c P-0-V2-.&)< "?w IL(,.),)CIO, - �l�Y?a Type of Building: Dwelling No.of Bedrooms/15ri tv, Lot Size 5000 sq.ft. Garbage Grinder( ) 9!F Other Type of Building No.of Persons Showers( ) Cafeteria( ) Other Fixtures r, Design Flow(min.required) t�� �- gpd Design flow provided y `J gpd Plan Date Number of sheets Revision Date Title �.. �:— <:%c 11,E 6,4' (.r /C: °L. use_ks-( N k let k lh2t�.y.,2,� i'o r: Size of Septic Tank /So3 8'90 Type of S.A.S.3 3 1AR0 560,;a e dtwvn �33.5 N 1-R,.Y3 Description of Soil Nature of Repairs or Alterations(Answer when applicable) r r Date last inspected: Agreement: , f The undersigned agrees to ensure theconstruction and maintenance-offli-e-7aTore described on-site sewage disposal system in accordance with the provisions of Title 5 of the Environmental Code and not to p the system in operation until a Certificate of Compliance has been issued by this Board of Health. 1� Sign - Date Application Approved by (e'er "—"��`7 Date Application-Disapproved b -�_11' G� -' Date for the following reasons 'Permit No. ZQ y 6; j Date Issued 0" - - - - 'THE COMMONWEALTH OeMASSACHUSETTS ' BARNSTABLE,MASSACHUSETTS f (Certificate of Compliance THIS IS TO CERTIFY,that the On-site Sewage Disposal system Constructed( ) Repaired(i ) Upgraded Abandoned by �G�C`�c3 Gl <. Gr,�Ak`"u)(-iG0, ems,C - at (p. Gt�t,tk',k t t t`e has been constructed in accordance with.the provisions of Title 5 and the for Disposa1,System Construction Permit NoZ016" 14 dated Installer i Ut" �>�c t( c Uh Designer a�(1 �iYt<j tttt �2trtit� �C #bedrooms 7 Approved desigp flpw l 5 gpd ` The issuance of this permit shall not be construed as a guarantee that the system wID function a gne•. "`" Date 1'� 11 Inspector - ----- - -- ---- --- ------------------ --------------------- ----------------------------- No. 76(b 0 Fee*/5 THE COMMONWEALTH OF MASSACHUSETTS PUBLIC HEALTH DIVISION-BARNSTABLE, MASSACHUSETTS Misposal &pstem Construction permit Permission is hereby granted to Construct( ) �R(epair(✓) Upgrade( ) Abandon( ) System located at l ri Sj ( �)e�_r i/S '-E 1 d t L�4 !``� L(C.Li}i') Pe;F--t- a v and as described in the above Application for Disposal System Construction Permit. The applicant recognized his/her duty to comply with Title 5 and the following local provisions or special conditions. y�J Provided:ConstrIti must be completed within three years of the date of this permit. :. D"ateo`�'' t��t7/� Approved by fi 12-2018 03:17 From: To:15087906304 Page:1/1 Town ®f Bl m, tzble ,ter Regula4®aY Sakes Thomas F.Geiler,yDir®ctOr a Public,Health IDMAOU s� p Thomas McKean,Director 700•Main Street,Hyannis,X&02601 Fax: 508-790-6304 Office: 508-862 4644 ][�staa�t®r&ID i er Icertn�t'604 F Orin U( (-tLSewm aPeai� �a16— l y Assessmr's Map�'arceAyDate:. g l[rps4a➢fler: . �o�—'" 6 1�1�.0 /bl�r�- 3 ,le— � .address: - o.Address: / was issued a pew to instaU a On (installer W Q(,V � �-' based on a desiga drawn by septic system at (address) ` Gated 7 a�a�tc GeV /d . / stem.referenced above was ✓ X certify that the septic sy installed substantially according toes such.as lateral relpcation of the the design, which may include.minor approved cbang distgblition box and/or septic,tank• ed with major cbanges (i.e. Z cextifyy that the septic system referenced above was install greater than 10' lateral relocation of the SAS or any veocal relocation �ons Plan revision of the septic system)but meaccordance with State 8�Local Regal certified as�-built by ded9n N OF M4 DANIELA. � OJALA Qnstauer'S lgnattiue) " CIVIL No.46502 �SSiONAL esigner's iglR.attzce) (Affix Designer's Stamp Hete) O � x; Dxc ax,T� IDxvrsJr�D1v. t ..® C LE L OT BF, I YD UNTIL B TWS O RM RE BY�A U ]!1' LIC T ID O1�L YOYJ. Q:ffc4th/,%p0c/l CettificationF.orm 9-26-04.doe t V ���� f Stanton, David From: Stanton, David Sent: Wednesday, June 13, 2018 4:28 PM To: Bortolotti Construction Cc: Daniel A. Ojala; McKean, Thomas; Florence, Brian; Parziale, Jim Subject: 68 Wachusett Ave, Hyannis. Septic permit 2016-144 Septic permit 2016-144 for 68 Wachusett Ave, Hyannis is being placed on hold for now. The septic permit was issued in error, so the project cannot move forward until it complies with the code. This is being placed on hold to prevent any further costs or issues until the problem is resolved. The following are issues to be resolved: 1. The State does not allow an increase in flow to a septic system with a sieve analysis. 2. This septic permit is associated with another property which was once a single lot. When the property was divided, it created variances for the new septic system to be installed at the main house (#62 Wachusett Ave.) These variances must be granted by the Board of Health. If the said properties remained as a single lot, a variance before the Board of Health would not be required. A title V inspection was not submitted to the Health Division for the property transfer. Thanks David David W. Stanton, IRS Chief Health Inspector Town of Barnstable 200 Main Street Hyannis, MA 02601 Direct phone: (508) 862-4647 Health Dept. phone: (508) 862-4644 Health Dept. fax (508) 790-6304 1 a , I 1 i BOUDREAU &BOUDREAU,LLP 396 NORTH STREET HYANNIS,MASSACHUSETTS 02601 Telephone:(508)775-1085 Telefax:(508)771-0722 Philip Michael Boudreau Mark H.Boudreau February 2, 2016 Tom Perry, Building Commissioner Building Department Town of Barnstable 200 Main Street Hyannis, MA 02601 RE: Mark Grenier 62 Wachusett Avenue, Hyaiznis Port Dear Mr. Perry, I represent Mark Grenier in connection with his ownership of real estate known and numbered as 62 Wachusett Avenue in the Village of Hyannis Port. My purpose in writing is to request a determination from you that the property in question consists of two (2) separate legal lots, each containing a single family residence, that will allow the title to be split for zoning, title and assessing purposes. The property consists of Lot 25 and Lot 26, as shown on a plan entitled "Plan of Seashore Lots Belonging to the Hyannis Land Company In Hyannis Barnstable County Mass. R. Cook Surveyor Scale 200 ft. to an inch 1872." Each of the lots measures on the plan to be fifty (50') feet by one hundred (100") feet, and are both located on Wachusett Avenue next to each other. At all times, the properties were conveyed by deeds with separate designations of the lots and with separate descriptions of the lots. Lot 25 is improved with a single family residence that was constructed in 1890. Lot 26 is improved with a single family residence that was constructed in 1950. Both lots have been in common ownership since 1947 and previously were owned by the same woman from 1927 until she combined ownership of the lots into herself and her husband through straw deeds in 1946. Massachusetts General Laws Chapter 41 Section 81 K was enacted in substantially its present form in 1953. At its enactment, it validated all sub- divisions recorded before February 1, 1952 to the extent the lots in question have been sold and ways appurtenant to them established before that date. Clearly, Lot 25 and Lot 26 are located on a valid subdivision plan. Wachusett Avenue has serviced the home on Lot 25 for over one hundred years. My client's intentions are to create a perimeter plan (81X plan) of each lot separately and to record the plans. After that, Mr. Gremer will bring copies of the recorded plans to Barnstable Assessing Department to have the Town start to tax the lots separately. . For lots held in common ownership, the second sentence of M. G. L. Chapter 40A Section Paragraph 4 now reads: Any increase in the area, frontage, width, yard, or depth requirement of a zoning ordinance or by-law shall not apply for a period of five years from its effective date or five years after [January 1, 1976] whichever is later, to a lot for single and two family residential use, provided the plan for such lot was recorded or endorsed and such lot was held in common ownership with any adjoining land and conformed to the then existingrrequirements as [January 1, 1976] and had less area, frontage, width, yard or depth requirements than the newly effective zoning requirements but contained at least seven thousand five hundred square feet of area and seventy-five feet of frontage.... An earlier version of this second sentence was added to the old Zoning Enabling Act by 1961 Mass. Acts. 435, which allowed residential construction for five years after the date of the recording or endorsement (of the zoning change) if, at the time of such recording or endorsement, the lot conformed to existing requirements and contained at least 5,000 square feet of area and 50 feet of frontage. The Town ByLaws indicate that the first sub-division control laws pertaining to area and frontage in the Village of Hyannis Port were recorded in 1949 (Article 75), Hyannis Port being among the first villages where such restrictions applied. The house on Lot 25, which is a one-bedroom cottage, was finished in 1950, well before the lot's grandfathering rights lapsed. Therefore, no merger of Lot 25 and Lot 26 occurred. This building is separated metered for electricity and natural gas. It contains the original kitchenette, a full bathroom, a bedroom and a sitting room. Over the course of some years, it was rented out, in conjunction with the house on Lot 26 under the name of Hillcrest-by-the-Sea. Otherwise, it was used by the owner as a•residence. Both of the residences on Lot 25 and Lot 26 have been used regularly since their construction. mainly as Summer homes. I would respectfully request that you sign where indicated below to confirm your agreement that each of these lots are grandfathered as legal, separate,lots. . 1%7Do i e Thank you for your kind attention to this matter. I I Sincerely, Aark H. Boudreau NM Encl. Agreed: _,:/ _ I i i i J Stanton, David From: Daniel A. Ojala PE, PLS <downcape@downcape.com> Sent: Friday, June 15, 2018 9:50 AM To: Stanton, David Cc: Florence, Brian; McKean, Thomas; Parziale, Jim; Craig Ashworth Subject: 68 Wachusett Ave, Hyannis. Septic permit 2016-144 Attachments: TOM PERRY LETTER 2-2-16.pdf; PB 663 PG 41.pdf; PB 663 PG 42.pdf; Assessors GIS Map.JPG; 18-164 existing floor plans.pdf; 18-164 EB Norris T5 rev. 5-25-18.pdf; 18-164 perc sheet 68 Wachusett EB Norris.pdf; 18-164 EB Norris T5 rev. 5-25-18.pdf; 18-164 EB Norris BOH filing.pdf Hi, David: I put short answers in red below, these are a little longer responses: Regarding#1: Regarding#68 Wachusett,the plan says to do the perc test at time of installation, can this be scheduled ASAP? Regarding#62 this was an existing 5 bedroom house (one on first floor, 4 on second floor), going to a four bedroom design, so not "new construction" which would require the perc test, so sieve should be o.k. with local approval. (properly assessed as 5 bedroom). The variances for#62 are clearly stated on the plan,they need to be applied for under maximum feasible compliance, as no increase in septic flow, they have been applied for(see attached). Regarding#2 The dwellings are on two separate legal developed lots, shown as Lot 25 and 26 on Plan Book 26 Page 95, and later on the attached perimeter plans. The Town Building Commissioner confirmed the owners position that the properties were always separate developed lots protected through all zoning changes, (see attached letter).They were formerly improperly merged for assessing purposes, causing the below confusion. Not sure on the Title 5 inspection, I think the new owners just conceded to upgrade the systems using these designs? Thanks, Daniel A. Ojala PE, PLS down cape engineering, inc. 939 Main St.Yarmouthport, MA 1-508-362-4541 x106 1-508-362-9880 fax downcape@downcape.com This Electronic Message contains information from the engineering firm of down cape engineering, inc., which may be privileged. The information is intended to be for the use of the addressee only. If you are not the addressee, note that any disclosure, copy, distribution or use of the contents of this message is prohibited. From: Stanton, David (mailto:David.Stanton@town.barnstable.ma.usj Sent: Wednesday,June 13, 2018 4:28 PM To: Bortolotti Construction <bortolotticonstruction@verizon.net> Cc: Daniel A. Ojala <downcape@downcape.com>; McKean,Thomas<Thomas.McKean@town.barnstable.ma.us>; i - 1 Florence, Brian <Brian.Florence@town.barnstable.ma.us>; Parziale,Jim <Jim.Parziale@town.barnstable.ma.us> Subject: 68 Wachusett Ave, Hyannis. Septic permit 2016-144 Septic permit 2016-144 for 68 Wachusett Ave, Hyannis is being placed on hold for now. The septic permit was issued in error, so the project cannot move forward until it complies with the code. This is being placed on hold to prevent any further costs or issues until the problem is resolved. The following are issues to be resolved: 1. The State does not allow an increase in flow to a septic system with a sieve analysis. Perc at time of install is needed per perc form for#68, can we schedule ASAP? 2. This septic permit is associated with another property which was once a single lot. Not true. When the property was divided, it created variances for the new septic system to be installed at the main house (#62 Wachusett Ave.) These variances must be granted by the Board of Health. If the said properties remained as a single lot, a variance before the Board of Health would not be required. A title V inspection was not submitted to the Health Division for the property transfer.These lots have never merged and were improperly assessed as one lot, see attached information including letter from building commissioner. A BOH variance filing under maximum feasible compliance for#62 has been submitted, #68 needs nothing except perc at time of install. Thanks, David _ David W. Stanton, IRS Chief Health Inspector Town of Barnstable 200 Main Street Hyannis, MA 02601 Direct phone: (508) 862-4647 Health Dept. phone: (508) 862-4644 Health Dept. fax (508) 790-6304 2 down cape engineering, iSJEVE SOILS ANALYSIS 62 WACHUSSETT AVE HYANNIS, MA(COTTAGE) DATE OF REPORT: 2129/16 JOB : 6,GRAIN SIZE ANALYSIS-SIEVE TEST SITE: MWACHUSSETT AVENUE, HYANNIS LOCATION: DCE TEST HOLE (COTTAGE LOT) SIEVE ANALYSIS Weight Sample(Grams): 132.8 SIZE ;WEIGHT RETAINED % RETAINED % PASSED ------------ .......... 4--------------------r 1" 0.0; 0.0%: 100,0 0 ------------ -•------------------>---------------------I------------------ 3/4" =�a--------------0 0%: 100.0% ------------- ••-------- - ----------------- 1/2" 0.0; 0.0%; 100.0% -------------i -- - ----------------------r------------------ 3/8" 0.0; 0.0% 100.0% ------------ ------------------------------------------------�------------------ #4 0.0; 0.0%: 1 . . #10 5.5; 4.1%� 95.9% #26---------4..........................A----------------. 0--. -.-.-..---.---- #20 29.7� 22.4% 77.6% #40 75.6: 56.9%; f 43.1 •------------- ..........................Y---------------------l.................. _ #50 101.1; 76.1%; ------------- 4---------------------I------------ #80 122.6; 92.3%: 7.7% ------------ --------------------------a--------------------->.................. #100 126.7; 95.4%: 4.6% #200 -___ -•----------------iil. _98.8%t________-___1_2% --------------i -•r------______ PAN: 131.8; 100.0%; 0.0% SAMPLE:-- ---------------------32.8.;---------------------------------------- SAMPLE: 132.8; NOTE:TEST ON PASSING#4 ONLY, 0.6% RETAINED ON#4<45%O.K. RESULTS: SOIL CLASSIFIED AS AASHTO A-1-b(GRAVEL&SAND)(UNCOMPACTED) PERCENTAGE OF MATERIAL PASSING#4 SIEVE : #4 100% (TEST ONLY MATERIAL PASSING#4) OK #5010%-100% OK #100 0%-20% OK #200 0%-5% OK SAMPLE MEETS TITLE 5 FILL SPECIFICATION >98%SAND RESULTS: PERMEABLE MATERIAL-CLASS 1<2 MINAN. MATERIAL(0.7 P /SF) NONCOMPACTED NOFMgSS9 SOIL DESCRIPTION- MEDIUM SAND DANIELA. o OJALA 0 CIV�IL 46 �. G l S T Sg/ONAL�� TRANS. NO.: ' -APPLICANT: �. 'orr'o � ADDRESS: �°�� � �� �f' r -y DESIGN `LOW: ' gpd REVIEWED BY: DATE: N/A OK NO 0-0"(�_�!. �.l s� a""'w'. Legal boundaries denoted [310 CMR 15.220(4)(a)] Street, Lot tax par cel n wnb er and lot number no ted on pl an 31 0 CMR 15.220(4)(u)] Locus Provided [310 CNM 15.2204(t)]. Plan proper scale? (1"=40' for plot plans, 1"=20' or fewer for components) [310 CMR 15.220(4)] Easements shown [310 CMR 15.220(4)(b)] System located totally on lot served [310 CMR 15.405(1)(a) for upgrades]- if not, a uariaazce is required [310 CMR 15.412(4)] Location of impervious surfaces (driveways,parking areas.etc.) [310 CMR 15.220(4)(d)] Location all buildings existing and proposed 310 CMR 15.220(4)(c)] , Location and dimensions of system components.and reserve areas. [310 CMR 15.220(4)(e)] System Calculations [310 CMR 15.220(4)(f)] d daily flow septic tank capacity(required and provided) soil absorption system (required and provided) whether system designed for garbage grinder North arrow [310 CMR 15.220(4)(g)] Existing and proposed contours [310 CMR 15.220(4)(g)] 4 Location and log of deep observation holes (existing grade el. on each test) [310 CMR 15.220(4)(h)] Names of soil evaluator and BOH representative [310 CMR 15.220(4)(h) and(i)] Location and date of percolation tests (performed at proper elevation?) [310 CMR 15.220(4)(i)] Percolation test results match loading rate? [310 CMR 15.2421 Certification statement by Soil Evaluator [310 CMR 15.220(4)0)] Observed and Adjusted growadwater (method for adjustment given or indicated) [310 CMR 15.103(3) and 310 CMR 15.220(4)(n)] Address Sheet 1 of 7 N/A OK NO F ation of everywater supply, public andprivate, [310 CMR 20(4)(k)] within 400 feet of the proposed system location ni the case urface water supplies and gravel packed public water supply within 250 feet of the proposed system location in the case within 150 feet of the proposed system location in the case of private.water supply wells Location of all surface waters and wetlands located up to 100 ft. beyond se tbacks listed in 310 CMR 15.211 and any catch basins located within 50 ft. [310 CMR 15.220(4)(1)] Water lines and other subsurface utilities located[310 CMR 1 15.220(4)(rn)] (if water line cross see 310 CMR 15.211(1)[1]) Profile of system showing invert elevations of all system components and the bottom of the SAS [310 CMR15.220(4)(o)] Stamp of designer [310 CMR 15.220(1) and 310 CMR 15.220(2)] Stamp of Registered Land Surveyor (required if construction activities within 5 ft. of lot line) [310 CMR 15.220(3)] Test Holes adequate (two in each of the primary and reserve unless trenches as permitted in 310 CUR 15.102(2) or as approved for an upgrade under LUA at 310 CMR 15.405(1)(k)] Test hole adequate to demonstrate four feet of suitable material? [310 CMR 15.103(4)] Test Holes adequate to confirm adequate groundwater separation? [310 CIVIR 15.103(3)] Benchmark within 50-75' of system [310 CMR 15.220(4)(q)] Materials specifications noted? [various sections of 310 CMR 15.000] System components not>36" deep (unless Local Upgrade Approval or LUA requested) [310 CMR 15.405(1(b)] Sheet 2 of 7 Address N/A OK NO Size OK? [310 CMR 15.223(1)] Inlet tee located ten inches below flow line [310 CMR 15.227(6)] Outlet tee 14" or 14" + 5" per foot for increase ft depth[310 CMR / 15.227(6)] V Outlet tee with gas baffle or approved filter [310 CMR 15.227(4)] Note regarding installation on stable compacted base [310 CMR 15.228(1)] Separation between inlet and outlet tees (no less than liquid depth) [310 CMR 15.227(2)] Inlet/Outlet elevations at least 12" above High groundwater (except as described 310 CMR 15.227(5)) or permitted for upgrades under LUA [310 CMR 15.405(1)(k)] Minunum cover 9" (Tanks buried more than 9" must have risers / on all openings and on the d-box) [310 CNM 15.2228(1) and 310 CMR 15.232(3)(f)] T11ree access covers (inlet and outlet must be 20" or greater) - middle access at least 8" (by 7/07) [310 CMR 15.228(2)] Access to within 6 " of grade - one port for systems<1000gpd, two for systems>1000 gpd [310 CMR 15.228(2)] All at-grade covers secured to unauthorized access? [310 CMR / 15.228(2)] > 10 ft from building foundation [310 Ma 15.211(1)] Buoyancy calculation Required/Done [310 CMR 15.221(8)] H-20 Where appropriate? [310 CMR 15.226(3)] ' Setbacks from resources [310 CMR 15.211] 3�z4i'. e➢YITJI,P.Iiet_fll�{5t Required when other than single-family dwelling or flow>1000 d 310 CMR 15.223 1 First compartment 200% daily flow; Second compartment 100% daily flow [310 CMR 15.224(2) and(3)] "U" pipe through or over baffle, outlet of each compartment with gas baffle or approved filter [310 CMR 15.224(4)] Address Sheet 3 of 7 N/A OK NO Located at least ten feet from any water line? [310 CMR 15.222(2)] Disposal piping at least 18" below water line (when water and sewer cross, see 310 CMR 15.211(1)[1]) Cleanouts required/provided? [310 CMR 15.222(8)] Thrust blo cks sP ecified in force mains? 310 CMR Slope of sewer line not less than 0.01 (1/8"/ft) 0.02 preferable [310 CMR 15.222(6)] Proper pitch on all runs? (.005 within gravity-distributed trenches and beds) [310 CMR 15.251(9) and 310 CMR 15.252(2)(c)] Siphon problem/(leachfield below pump chamber) Endcaps or vent manifold specified? Size and orientation of discharge holes specified? (not smaller than 3/8" not larger than 5/8") [310 CMR 15.251(8) and 310 , CMR 15.252(2)(h)] Materials specified (310 CMR 15.251(5) specifies various pipe types allowed) ' , �D �g 7pT W} ~u..,.. 'A9.D���:?-®lY1E:yr�` z�: `wr � Y`x�..-`�t :� � -' -"'r."�..c Stable compacted base [310 CMR 15.221(2) and 310 CMR 15.232(2)(a)] Splash plate or baffle tee requixed on inlet/provided? (when pressure sewer to d-box or steep pitch of gravity sewer) [310 T . CMR 15.323(3)(a)] Riser if deeper than 9" [310 CMR 15.232(3)(f)] Inside minimum dimension 12" [310 CMR 15.232(2)(b)] p Minimum sump 6" [310 CMR15.232(3)(e)] Watertight cover if<2000gpd); waterproof manhole if>2000gpd ; } [310 CMR 15.232(3)(d)] c�.ft & `l: C CtF'S .• Ea .�ac � e,R"irtr? ,.�' .c `sv }.. �`� 1 Capacity(emergency storage above working—design.flow)? [310 CMR 231(2)] 4 Proper setbacks [310 CMR 15.211 (sane as septic tanks)].- Watertight 20-in minium access manhole at least 20"MUST BE TO GRADE [310 CMR 15.231(5)] Service components accessible (not too deep with piping, disconnects accessible) Alarm floats - alarm on circuit separate from pumps specifiedT Exceeds two units must have two pumps operating in lead-lagf mode. [310 CMR 15.231(6) and(8)] Stable Compacted Base [310 CMR 15.221(2)] Buoyancy calculations needed ? Provided? [310 CUR 15.221(8)] Address Sheet 4 of 7 NIA Oki NO #- <"...v 'a� `;y;�Vv fit. r;'tr� Calculations correct? 4 feet of naturally occurring material demonstrated? [310 CMR 15.240(1)] Required separation to groundwater? [310 CMR 15.212)] Aggregate specified as double washed [310 CMR 15.247(2)] J System Venting required/provided? (system under driveway or >36" deep) [310 CMR 15.2411 Inspection ports specified and within 3"final grade? [310 CMR 15.240(13)] V Breakout requirements met? (No violation of breakout elevation within 15 ft of SAS unless barrier) [310 CMR 15.211(1)[4] and Guidance Document] Chambers and Gal, in trench configuration supplied with inlet every 20 ft. [310 CMR 15.253(6)] Each structure with one inspection maDhole(if>2000 gpd must / be to grade) [310 CMR 15.253(2)] J Aggregate I'minimum-4' maximum. [310 CMR 15.253(1)(b)] 2' sidewall credit maximum [310 CNa 15.253(1)(a)] In bed l.�T.configuration, inlet every 40 sq. ft. [310 CMR 15.253(6)] Width 2'minimum 3'maximum [310 CMR 15.251(1)(b)] 100 feet-maximum length [310 CMR 15.251(1)(a)] Minimum separation 2x effective depth or width whichever greater(3x if reserve between trenches) [310 CMR 251(1)(d)] Situated along contours [310 CMR 15.251(2)] Breakout OIL? [310 CMR 15.211(1)[4] and Guidance Document] �"< a �,..k L.'3 1.'S�T" � iJ as �e F "�8dk�'�"'�`°':r'�F,�.'s, ,fir r,.�"y`� � i•a: BE� Si�� (�T1�aaaan-"um��z�`�iF�bed�o�ael�QO� gi?d),.. minimum 2 distribution lines [310 CMR 15.252(2)(a)] Maximum separation between lines 6' [310 CM R15.252(2)(d)] Maximum separation between lines and outside of bed 4' [310 CMR 15.252(2)(e)] Aggregate depth below discharge pipes 6" minimum, 12" maximum. [310 CMR 15.252(2)(g)] Separation between beds 10'minimum. [310 CMR 15.252(2)(f)] Bottom area used in calculations only [310 CMR 15.252(2)(i)] Address Sheet 5 of 7 N/A OK NO .. ..............._.. __ ._.._..._.,.... 'g, ;� B+ IIIdV,' 5?? G�,d pressure Dosed System ? Provided pump and piping / calculations as required [310 CNIR 15.220(4)(r)] Pressure dosing required on all systems>2000gpd or alternative systems under remedial approval [310 C1VIR 15.254(2) and I/A J' Remedial Use Approvals] If used in gravelless system-make sure jet is directed as not to / scour soil interface [Guidance Document] Inspections once per year (systems<2000 gpd) or quarterly J (>2000gpd) good to note on plan [310 CMR 15.254(2)(d)] Construction in fall -Did the plan specify that the fill shall meet I V the specification of 310 CMR 15.255(3).7 Impervious barrier and/or retaining wall ? [Guidance Document] Impervious barrier installation must be supervised by designer[310 CMR 15.255(2)(b)] Retaining wall must be designed by Registered Professional Engineer[310 CMR 15.255(2)(a)] Side slope not exceed 3:1 ? [310 CMR 15.255(2)] Breakout requirements met? [310 CMR 15.252(2) and Guidance Document] At least 5 ft. from impervious banter to edge of SAS (10 ft. recommended) [310 CMR 15.255 (2)(e)] Check DEP Approval letters for credits and design conditions If used with pressure dosing do not allow pressure discharge , to scour soil interface r' t sates % ` A1�e y�e,Sep e ys %fll " P �onIr- e tern Was DEP Approval Letter provided and/or have you reviewed the letter for conditions? Is the technology being properly applied and does it meet all DEP Approval Conditions? Is there a note on the plan regarding the requirement for perpetual maintenance agreement? Any alarms involved on separate circuits Did the applicant submit an operation and maintenance manual? Has applicant submitted a copy of a maintenance fTla�irtrxcet �� �2, rAr:the variances listed on the plan? [310 CIVtR 15.220 (4)(q)] RLS Stamp necessary on plan if a component is within five feet of property line [310 CNM 15.412(4)] New construction or increased flow proposed- [Refer to 310 a CMR 15.414] Address Sheet 6 of 7 N/A OIL NO i 1' 1 -i E-,T '1. ! �It 4 4..1�§ .'F t . 'k ` 3 '1'.•3� P µ.ix yx ' S V R Is the system in a Designated Nitrogen Sensitive Area(Zone H for a public supply well)? [310 CMR 15.214, 310 CMR 15.215 and / 310 CMR 15.216 - also refer to Policy regarding upgrades of such existing systems] Is the system proposed on the same lot as served by private well ? [310 CMR 15.214(2)] Are the nitrogen loads proposed in compliance? [310 CMR 15 216(1)] Pumping to septic tank ? [ 310 CNa 15.229] Shared System[310 CMR 15.2901 1 V Address Sheet 7 of 7 _I M8229:35"yi 50.00' M8229 35"�•y LOT 25 5000' CB FND PB 663 PG 42 h DISP. 5,000 S.F. ;� ►� N52'30'25"E 0 0.11 AC. ^ XISTING 0.15' COTTAGE #68 N8229'35 EXISTING 000 4') p DWELLING Z I :o O #62 L o ° I 'LOT 26 w I PB 663 PG 41 ,� o 5,000 S.F. p N ►� 1 1 0.11 AC. •"� O ►��' o o COVERED PORCH 3 1 0 1 � DWI CB0) 0 58229 35'E FND 1 HELD 5000, a 10 p 58229'35'E CB FND S8229'35'E 40.pp, DISP. WACntjSN20'42'12"W 0.06' ETTA VENt E Scale:1 20' 0 10 20 30 40 50 FEET EASEMENT SKETCH PLAN off 508-362-4541 IN I fax 508-362-9880 downcope.com © HYANNISPORT, MA down cope engineering, Me. WACHUSETT AVENUE civil engineers PREPARED FOR land surveyors JOHN ALE 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02575 SCALE: 1' = 20' DATE: DULY 18, 2018 DCE #18-164 Town of Barnstable P# .�`/73 Departiment of Regulatory Services Public Health Division M,, I Date /S �p a619 �� 200 Main Straet,Hyannis MA 02601 Date Scheduled Time Fee Pd. 7u� o26)0 (z �5� Soil Suitability Assessment for Sew ` e Disposal Performed-By: ban,' i Witncssed By: •LOCATION&.GENERAL INFORMATION Location Address Y� Owner's Name RinlS/oo Address Assessor's Map/Parcel' z 7/�g� Engineer's Name NEW CONSTRUCTION REPAIR ' j J Telephone# S 0f � Land Use- La lNr-7 0 --5Slopes(96) Surface Stones G e Distances from: Open Water Body (G� ft Possible Wet-Area>( ft Drinking Water Well ,�/00 ft Dlalnage Way (t� ft Property Line {0 ft Other ft SKETCH;(Street name,dimensions of lot,exact locations of test holes&pere tests,locate wetlands-in proximity to holes) , A i - - V) . C (O Dwell.ny lacy a I z�G Parent material(geologic) T 11 Depth t0 9eQrock Depth to Groundwater Sianding Water In Hole: IA// Weeping from Pit Rea Estimated Seasonal High Groundwater NIX D,FTERMINATION FOR SEASONAL'HIGH'WATER TABLE Method Used: ��9//6 U,/t— Depth Observed standing in obs.hole: In. Depth to soil mottled: lu,' Depth to weeping from side of obs.hole: In, Groundwater Adjustment , index Well-# Reading Dato: _ Index Well level , Adj,-thetbY ,y Add.draundwaterlxvel PERCOLATION TEST Data Timm,.._._, Observation Hole# 'Time at 9" — Depth of Pero Time at 6" Start Pre-soak Time @ Time(9"-611) _ End Pro-soak Rate Mia./Inch Site Suitability Assessment. Site.Passed Sito Failed: Add`6ti" ii�tional Testing Needed YIN) Original: Public Health Division Observation Hole Data To Be Completed on Back----------- ` ` ***If percolation test is to be conducted within 100' of wetland,you must first notify the ' Barnstable.Conservation Division at least one(1) weelt:prior to beginning. Q:ISEPTIC1WERCFORM.D0C DEEP•OBSER OBSERVATION le VA ON HOLE LOG Ho # , Depth from Soil Horizon Soil Texture Sdil Color Soil. Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Stoneit;Boulders. COT tsistency.%'Gravel) o- l to s �- y2 s /0 yR 41/� yz-7b' C, '5; L 10X�' 'i r fyq CZ 'M f . 2,5) 7/) DEEP OBSERVATION HOLE LOG Hole# Z Depth from Soil Horizon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Munsell) Mottling4�0`(Structure,Stones,Boulders. CQnsistgnov, I _y� L L Jay 10_l z DEEP OBSERVATION HOLE LOG Hole.# Depth from Soil Hodzon Soil Texture Soil Color Soil Other Surface(in.) (USDA) (Muusell) Mottling (Structure,Stones,Boulders.. Consistency, a- S .. - z + L s ley f� Aj DEEP OBSERVATION HOLE LOG Hole# Depth from Soil Horizon Soil Texture Soil Color gall Other Surface(in.) (USDA) (Munsell) Mottling (Structure,Slopes;Boulders, Cons! 10d30 a • L S I0yks/� - Flood Insurance Rate Man: l Above 500 year flood boundary No Yes Within 500 year boundary No "+ Yes Within 100 year flood boundary No.. ,,, Yes Depth of Naturally Occurring Pervious Materlal Does at least four feet of naturally occurring pervious material exist in all areas observed thrpughout the area proposed for the soil absorption system? ` If not,what is the depth of naturally occurring pervious material? .. Certification / I certify that on �(; f `� (date)I have passed the soil evaluator examination approved by the Department of Environmental Protection and that the above analysis was performed by me consistent with . the required training,expertise and experience described in 10 CMR 15.017. Signature Data; Q;15aPnL'\PBRCFORM.DOC NOTES LEGEND. cJ 1. DATUM IS ASSUMED -- 99 --- EXISTING CONTOUR SYSTEM PROFILE ALL SYSTEM COMPONENTS SHALL BE VENT 2. MUNICIPAL WATER IS EXISTING MARKED WITH MAGNETIC TAPE OR X 991 EXIST. SPOT ELEV. 2' CAST IRON COVERS TO GRADE OR CONCRETE (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. Ook -[99]- PROPOSED CONTOUR FIRST FLOOR EL. 26.45' COVERS TO WITHIN 6" GRADE, COORDINATE W/ OWNER PROVIDE MIN. 20" DIAMETER WATERTIGHT 4. DESIGN LOADING FOR ALL PROPOSED PRECAST 2" PEASTONE OR GEOTEXTILE H-20 CAST IRON- COVER TO GRADE UNITS TO BE AASHO H-20 Smifh FILTER FABRIC OVER STONE TH8 4] PROPOSED SPOT EL. \ 25•0' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 24.5' 5. PIPE JOINTS TO BE MADE WATERTIGHT. Jae �orsfo" TEST HOLE PRECAST H-10 NOTE: 2" MIN. WALL 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE O THICKNESS REQUIRED BLOCKS OR WITH 310 CMR 15.000 TITLE 5. RISERS (TYP.) PRECAST RISERS ( ) 2> SLOPE OF GROUND ,a: 2 s" MIN. SUMP PIPES H40 PVC LEVEL 1ST 2' COMPONENTS MORTAR ALL H-20 *' 4' 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND o GA UTILITY POLE 12' MIN. INT. DIM. 4' (TYP.) ap ENDS SIDES 21.5' NOT TO BE USED FOR LOT LINE STAKING OR ANY a Locus *23.9't 10" 1500 GAL H-20 14" - °°°°°°°°° OTHER PURPOSE. FIRE HYDRANT '~ 21 .56' TEE SEPTIC TANK TEE o ° ° ®®®� f ®®® ®®OO ���� ' °°°°°°° oc us yYo 1 .31' 00°0°0°0°0°o WATERTEST D'BOX °o ®�®®®®�®®®® 0®®®®®®®0®® 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. ` ron9 Nantucket 0 0 o ..0... O ,o°o°o°o° p O O O ;000000Qo NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING GAS BAFFLE..` ,0000000o Sound �„�... � FOR LEVELNESS cv °o 9. COMPONENTS NOT TO BE BACKFILLED OR . o 20.77' 20.6' o°o°o°o° 18.5 4' LIQ. LEVEL (ACME OR EQUAL) ': ° ° o o CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD :, t....:•:.;,:•,. ,• . ..:.• •;0;0...� .• . L OF HEALTH. 0000000000000000000000000000000p00000000000�1. °o°o°o°o°0°0°0°00000°0°0°0°°00000000°0° H-20 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 0 0 0_o_0_n o•O 0000,00000 0 °_n_o.o 0 ALL 3/4"AR AROUND DOUBLE WASHED STONE 4' MIN. (3) UNITS REQUIRED 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' CALLING DIGSAFE (1-888-344-7233) AND COMPACTION. (15.221 [2]) ;r, VERIFYING THE LOCATION OF ALL UNDERGROUND & NOT TO SCALE L6 OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 287 PARCEL 81-1 ( 5.8% SLOPE) ( 2 % SLOPE) ( 1 % SLOPE) PLLAN BOOKR663 PAGE GARET E41 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SYSTEM DESIGN. H-20 H-20 H-20 13' BOTTOM TH-1 SHALL BE REMOVED 5' BENEATH AND AROUND THE DEED BOOK 30860 PAGE 152 FOUNDATION- 39' SEPTIC TANK 27' D' BOX 12' LEACHING NO GROUNDWATER FOUND PROPOSED LEACHING FACILITY. • FACILITY 12. EXISTING LEACHING FACILITY SHALL B PUMPED GARBAGE DISPOSER IS NOT ALLOWED AND REMOVED OR PUMPED AND FILLED WITH CLEAN EXISTING 2 BEDROOM DWELLING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL SAND. UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 I .TEST HOLE LOGS USE A H-20 1500 GAL. SEPTIC TANK --- _ ENGINEER: DANIEL E. GONSALVES, SE #13587 LEACHING: DAVID STANTON, RS SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD N82 29 35' WITNESS:w 1 15 16 BOTTOM 33.5 x 12.83 (.74) = 318 GPD DATE. 50 00' PERC. RATE _ < 2 .MIN/INCH TOTAL: 615 S.F. 455 GPD � ' N52°30'25"E CB FND DISP. UNSUITABLE SOIL USE (3) H-20 500 GAL. LEACHING CHAMBERS CP 10.15' CLASS I SOILS P# 14932 (ACME OR EQUAL) WITH 4' STONE ALL AROUND 5' ELEV. ELEV. ELEV. ELEV. CLEAN UT 0» 25' O., 25 0„ 25' 0» 4 25' (TYP.) A A A Xq EXISTING /LS /LS LS BLS 6 10YR 3/2 1OYR 3/2 ,� 1OYR 3/2 10YR 3/2 APPROVED DATE BOARD OF HEALTH MA LOT 26 COTTAGE 14 12 8 10 PB 26 PG 95 5,000 S.F. B B B j 0.11 AC. I R /iS /LS �L_S /L _ II 10YR 4/4 10YR 4/4 10YR 5/6 10YR 5/6 I \ 42" 21.5' 46„ 21 .2' „ . / / / 24 23 30 22.5 b u0 C1 C1 C1 C W N p --_ --- _ - SIL SIL -_ _... - _ _ SI_L Si I o 10YR 6/4 10YR 6/4 TOYS 5/4 1OYR 5/4 o 96 17 90 17.5 84 18 84 18 SEWER LINE TO BE SLEEVED WITHIN 10' o �� r x OF WATER SERVICE SIEVE C2 C2 C2 C2 u� O o 00 c o 3 0 [25] 0MS MS MS MS o ��` 2.5Y 7/3 2.5Y 7/3 2.5Y 7/2 2.5Y 7/2 0 0 -- cn ( I c 144» 13.0' 144" 132" '0 . 14.0 132 14.0m 4"X4" OAK CURB STOP MARKER PAINT BLUE. C ITH4 �� 10 0;} PROP. VENT WITH NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED CHARCOAL FILTER AND CCARE SHALL BE TAKEN NOT TO DAMAGE Z D I -----�`� �� I BUGSCREEN (FINAL WATER SERVICE DURING HOME CONSTRUCTION. �s l PLACEMENT BY IT IS SUGGESTED TO BURY THE COVER 6", 2 THEN TELESCOPE TO SURFACE ONCE LANDSCAPING D I n II CONTRACTOR WITH m r�i I - I HOMEOWNER Vn IS COMPLETE. SET OAK MARKER 6" CLEAR MIN. � CONSULTATION) m IZ GAS LINE TO BE 5 m I Iw w I 1 RE-ROUTED STAINLESS STEEL C I W I I WIDE BAND STRAP ON SERVICE SADDLE 4.0' I I I CORPORATION COCK MUELLER OR EQ. TELESCOPING CAST IRON I I SERVICE BOX AND COVER z 10 0' O I 5' REMOVAL OF (110 COMPRESSION) BUFFALO 94E OR EQUAL MAINS WET TAP UNDER FULL PRESSURE ONLY. COMPACTED FILL �o I �- �II UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF O I LEACHING FACILITY, DOWN - = TRACING WIRE-#12 THHM, SOLID COPPER 3 i III- 4 4, TO SUITABLE SOIL LAYER. -III_ BLUE IN COLOR I I REPLACE WITH CLEAN MED. )II w TH TH _ , 2� , I SAND, TO MEET 1"'ITLE 5 SITE PLAN IIIIII_ 0� �� 1b.p I SPECIFICATIONS OF 310 \ \ SHELL CMR 15.255(3) OF III= CURB STOP DRIVE � �. � _ WATER TURNUELLER OR EQ. Z�I S82 » a / LEFT2g 35 -" 8 WACHUSETT AVE E MAIN TO OPEN ` ' SLEEVE ANY CROSSING UNDER SEWER WITH 2" SCH40 PVC 20' SECTION CENTERED ON SEWER. CB FND DISP. ®� 18" MIN. VERT. SEPARTION REQ. AT CROSSING, SEE GENERAL NOTE 18 ON SHEET 1. y� p /N20°42'12"W H Y N I S P T MA DOMESTIC SERVICES TO BE 1" 200 PSI CTS PLASTIC LINE TO DISTRICT SPECIFICATIONS SLEEVED WHERE REQ. 0•06' PREPARED FOR WAC 23 U `� DOMESTIC SERVICES ON SAME SIDE OF STREET AS WATER MAIN SHALL CONSIST OF 8' OF PLASTIC, OR AS � BENCHMARKNOFq �*�OFMgss� NECESSARY TO HAVE THE CURB STOP INSIDE THE PROPERTY LINE BY 2 FEET, A CORPORATION, CURB STOP, BOX, AND MARKER CONCRETE BOUND , Sqc E.B.(PUBLIC . A - , a< tiG ��a DANIEL Gm V NORRIS DOMESTIC SERVICES ON OPPOSITE SIDE OF STREET AS WATER MAIN SHALL CONSIST OF 33' OF PLASTIC, OR AS BLIC . ,`�]�j��-r EL. - 24.0 �� DANIELA. N�, A. a 1931 1 V o OJALA � o , ,OJAlA DATE. APRIL 29, 2016 NECESSARY TO HAVE THE CURB STOP INSIDE THE PROPERTY LINE BY 2 FEET, A CORPORATION, CURB STOP, BOX, AND MARKER " CIVIL �' SLEEVE ANY CROSSING UNDER SEWER WITH 2" SCH40 PVC 20' SECTION CENTERED ON SEWER w o No.46502 4PNo,40980 REV.: MAY 18, 2018 REV.: JULY 10, 2018 (WATER LINE) TRACING WIRE SHALL BE INSTALLED AND SPACED 12 INCHES ABOVE AND DIRECTLY ON TOP OF THE PLASTIC TUBING. CARE SHALL BE TAKEN SO TOSS THAT THE WIRE DOES NOT COME IN CONTACT WITH THE PLASTIC TUBING. WIRE SHALL BE STRIPPED AND WRAPPED AROUND THE C.C. THREADS OF g ipNA MAssgcy ��N FMASs9cy THE CORPORATION AT THE WATER MAIN WITH ONE ADDITIONAL FOOT OF WIRE LOOSELY TIED TO THE CURB STOP. SCdIe:1 = 1O �L.+�tc'� tea. DANIELA. �r /o DANIEL G s c OJAL4 , o h, A. \, CIVIL " OJALA . WATER S E R V I E s E T) O N 0 5 10 15 20 25 FEET ; No.46502 o No.40980 NOT TO SCALE D SSA � q, �O _ _ \���ficG���� °F /STER Ess\°� off 508-362-4541 oNAt vo SUR\J ( fax 508 362 9880 I downcope.com dawn cape engineering, iac. civil engineers land surveyors DATE DANIEL A. OJALA, P.E., P.L.S. 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 DCE # 18- 164 18-164 EB NORRIS.DWG SYSTEM PROFILE ALL SYSTEM COMPONENTS SHALL BE VENT NOTES MARKED WITH MAGNLLTIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. d e 5 e 2' CAST IRON COVERS TO GRADE OR CONCRETE (NOT TO SCALE) 1. DATUM IS ASSUMED P� FIRST FLOOR EL. 26.45' COVERS TO WITHIN 6" GRADE, COORDINATE W/ OWNER PROVIDE MIN. 20" DIAML-TER WATERTIGHT 2" PEASTONE OR GEOTEXTILE H-20 CAST IRON COVER TO GRADE 2. MUNICIPAL WATER IS EXISTING \ FILTER FABRIC OVER STONE 2% SLOPE REQUIRED OVER SYSTEM 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. Oak MINIMUM .75' OF COVER OVER PRECAST NOTE: 2" MIN. WALL 4. DESIGN LOADING FOR ALL PROPOSED PRECAST PRECAST H-10 THICKNESS REQUIRED BLOCKS OR UNITS TO BE AASHO H-�Q Smith RISERS (TYP.) PRECAST RISERS 2'0 4"OSCH40 PVC MORTAR ALL H-20' �arsfon , ..,FjTEE 6" MIN. SUMP PIPES LEVEL 1ST 2' COMPONENTS 5. PIPE JOINTS TO BE MADE WATERTIGHT. dd ,. 12" MIN. INT. DIM. 4 (TYP.) 4'ENDS SIDES 21 .5' 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 10� 1500 GAL H-20 21 :40' TEE SEPTIC TANK 1 .15' 000m ��O[� . zn0�0 WITH 310 CMR 15.000 (TITLE 5.) :AER1EST D'BOX o ° o .o'o.o7. THIS PLAN IS FORPROPOSED WORK ONLY ANDo°o°o°o°o°o° < c o aywo GAS BAFFLE::` ° ° ° ° ° ° VELNESS N '° ° ° ° °°°°o°°°°°°° o 0 0 o aoaooaa0000 ��a❑�aa000a o 0 0 0 NOT TO BE USED FOR LOT LINE STAKING OR ANY° ° ° ° o0000000000 � � o .� � 000000 0 ° ° ° 18.5' °°°°°°°° °°°°°°°° OTHER PURPOSE. Locus 4' LIQ. LEVEL (ACME OR EQUAL) ' 20.77 6 °°°°°°°° °°°°°°°° aC us c 000°00000000000000000°0000000000000000000°00� 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. ` rving Nantucket °000a0000o°0°,0°,0°,0�0000000�°00q,°,q,°g0g,°,o°,g00009 H-20 500 GAL. LEACHING t,L "HAMBER BY ACME PRECAST OR EQUAL. c % �7 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (3) UNITS REQUIRED o S011nu ALL AROUND PRECAST STRUCTURES 9. COMPONENTS NOT TO BE BACKFILLED OR 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' CONCEALED WITHOUT INSPECTION BY BOARD OF COMPACTION. (15.221 [2]) ;n HEALTH AND PERMISSION OBTAINED FROM BOARD LO OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP ( 5.1 % SLOPE) ( 2 SLOPE) ( 1 % SLOPE) CALLING DIGSAFE (1-888-344-7233) AND H-20 H-20 H-20 ' 13' BOTTOM TH-1 VERIFYING THE LOCATION OF ALL UNDERGROUND & . NOT TO SCALE LEACHING - NO GROUNDWATER FOUND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF FOUNDATION- 49' SEPTIC TANK 19' D' BOX 12' WORK. ASSESSORS MAP 287 PARCEL 81-1 FACILITY JOHN & MARGARET ALE I I 11. ANY UNSUITABLE MATERIAL ENCOUNTERED PLAN BOOK 663 PAGE 41 N82'29'35" N SHALL BE REMOVED 5' BENEATH AND AROUND THE *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL W DEED BOOK 30860 PAGE 152 UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS' 50 00, - PROPOSED LEACHING FACILITY. TEST HOLE LOGS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM / 12. EXISTING LEACHING FACILITY SHALL BE PUMPED CB FND DISP. AND REMOVED OR PUMPED AND FILLED WITH CLEAN > >� . DANIEL E. GONSALVES SE 13587 � SAND. CID v • N52'30 25 E ENGINEER. LEGEND- 5' 0.15' WITNESS: DAVID STANTON, RS 99 - EXISTING CONTOUR CLEAN UT DATE: 1/15/16 X 99 EXIST. SPOT ELEV. (TYP.) PERC. RATE _ < 2 MIN/INCH EXISTING UNSUITABLE SOIL [991-- PROPOSED CONTOUR 6 COTTAGE CLASS I SOILS P# 14932 LOT 2 6 I I FFLR = 26.45 ELEV. ELEV. ELEV. ELEV. 198 4] PROPOSED SPOT EL. PB 26 PG 95 I I O" 4 25' O" 4 25' of 4 25' O" 4 25' TH1 5,000 S.F. I TEST HOLE 0.11 AC. I o A A A A 2� SLOPE OF GROUND WI I /S //S /�S A 1OYR 3/2 1OYR 3/2 1OYR 3/2 1OYR 3/2 UTILITY POLE I I 14 12 8 10 L I to N O - B/ B/� Br B,/ _ FIRE HYDRANT p // NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING /S �LS S /LS 1OYR 4/4 , 1OYR 4/4 1OYR 5/6 1OYR 5/6 I c -SEWER LINE TO BE 42 / 21 .5 46 21 .2 24 / / / / 23 30 22.5 SLEEVED WITHIN 10' o ��, cw �� x OF WATER SERVICE j1/ Cl/ C1/ C1/ ° cri SIL SiL SiL SiL SYSTEM DESIGN: N IO N // // S S O O [25] �, 10YR 6/4 „ 10YR 6/4 84„ 10YR 5/4 18, 84„ 1OYR 5/4 18' D^ I o TH3 96 17 90 17.5 GARBAGE DISPOSER IS NOT ALLOWED O I o EXISTING 2 BEDROOM DWELLING w o \ c� \ SIEVE C2 C2 C2 C2 DESIGN FLOW. 4 BEDROOMS ® 110 GPD = 440 GPD o o N m r - MS MS MS MS USE A 440 GPD DESIGN FLOW m z I c I TH4 10 0,' PLOP. VENT WITH CHARCOAL FILTER AND 2.5Y 7/3 2.5Y 7/3 2.5Y 7/2 2.5Y 7/2 I I 75 ° I " BJGSCREEN (FINAL SEPTIC TANK: 440 GPD (2) = 880 D -c PLACEMENT BY CONTRACTOR WITH 144" 13.0' 144" 13.0' 132" 14.0' 132" 14.0' USE A H-20 1500 GAL. SEPTIC TANK I I I I HOMEOWNER r I rri CONSULTATION) NO GROUNDWATER ENCOUNTERED NO GROUNDWATER ENCOUNTERED LEACHING: m I I SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD w 1-Zi I I Gas LINE To BE TITLE 5 SITE PLAN c, I I I RE-ROOTED BOTTOM 33.5 x 12.83 (.74) = 318 GPD 5 I I z� i I OF w TOTAL: 615 S.F. 455 GPD O' 68 WACHUSETT AVE I I o I I 5' REMOVAL" OF USE (3) H-20 500 GAL. LEACHING CHAMBERS o I of " UNSUITABLE SOIL REQUIRED HYANNISPORT, MA (ACME OR EQUAL) WITH 4 STONE ALL AROUND I I AROUND PERIMETER OF O I I LEACHING FACILITY, DOWN t OF,a KOFMgS PREPARED FOR 14" , I I I c I TO SUITABLE SOIL LAYER. �C1ANiELs�c °`a� DAN1ELA�cti�s 1 I I REPLA(;E WITH CLEAN MED. s E.B. NORRIS TH - - _ 21 :�. , o OJALA = os - - I SAND, TO MEET �`� cn APPROVED DATE BOARD OF HEALTH MA I TH 10,0, 1 . SPECIFICATIONS OF 310 ;; 0.4098 CIVIL 1a. 0980 ° Na.46502 DATE: APRIL 29, 2016 \ SHELL CMR 15.255(3) °�Ss\o�e �F�o,ST4R``°�``� REV.: MAY 18, 2018 DRIVE sUR\1off 508-362-4541 sS�OrvaL E�'G _ S82'29'35"E fax 508-362-9880 c' CB FND DISP. I downcape.com �N20'42 12:W j 0.06' -._ down cape engineering, Inc. 23 DATE DANIEL A. OJALA, P.E., P.L.S. civil engineers WACUVS]ETTA BENCHMARK land surveyors CONCRETE BOUND Scale: 1 10' 939 Main Street Rte 6A_ , Bj jC' _ • EN EL. - 24.0 YARMOUTHPORT MA 02675 DICE 18- ' 64 I 1931� �� 0 5 10 15 20 25 FEET I 18-164 EB NORRIS.DWG I