Loading...
HomeMy WebLinkAbout0012 BISHOPS TERRACE alc� F SolarCity May 26,2016 Barnstable Building Department ent 200 Main Street Hyannis, MA 02601 RE: Change in Construction Supervisor License(CSL)- Building Permits Dear Building Commissioner: F ' Please be advised that we are changing our current CSL holder(information attached) and request that the former CSL information be discharged and the new CSL information be substituted for the following issued building permits: 1. 54 Zeno Crocker-Bassett JB-0262949-BP-16-1186; 2. 351 White Oak Trail-Black JB-0262887-BP-16-968; 3. 98 Skating Rink Road-Bleicher JB-0262700-BP-16-484; 4. 281 Commerce Road-Brazelton JB-0262404-BP-16-309; 5. 50 Old Mill Road-Burchell JB-0262749-BP-16-620; 6. 70 Delta Street-Fernandez J B-0262533-BP-16-652; �}y 7. 12 Bishops Terrace-Ford JB-0262554-BP-16-64; 8. 251 Woodside Drive-Garneau JB-0262548-BP-16-81; 9. 133 Dromoland Lane-Hannon JB-0262026-BP-16-103; 10. 106 Amelia Way-Jacobson JB-0262872-BP-16-980; , 11. 307 Skunknet Road-Marcantonio JB-0262855-BP-16-856; 12. 22 Audrey's Lane-O'Donnell JB-0262525-BP46-76; 13. 64 Hampshire Avenue-Weller/Pantone JB-0262817-BP-16-1127; 14. 2519 Main Street-Riley-Norton JB-0261326-BP-16-1219; 15. 70 Rudder Road-Smith-Sylvester JB-0262870-BP-1181; and, t 16. 11 Naushon Circle-Stirling JB-0235000-BP-16-1175. Pending Applications: 17. 404 Marstons Lane-Young JB-0262510-BP Pending; 18. 825 Route 6A-White-JB-02692437-BP Pending; 19. 30 Ironside Drive-Vatousiou JB-0262288-BP Pending; r 20. 116 Cherry Tree Road-Hoppensteadt JB-0262995-TB-16-1418; 21. 150 Old Craigville Road-Donovan JB-0263009-TB-16-1398; 22. 56 James Otis Road-Aube J B-0263019-TB-16-1398; 23. 23 James Otis Road-Bruning JB-0263022-TB-16-1397; 24. 116 Buckwood Drive-Almanza 1B-0262934-TB-16-1228; 25. 63 Bristol Avenue-Doucette JB-0262946-TB-16-1285; 26. 101 Seth Parker Road-Josselyn 1B-02629571-TB-16-1281; 112 Great Western Road,South Dennis,MA 02660 T (888)SOL-CITY solarcity.com AL 05500.AR M-8937.AZ ROC 24371I/ROC 246450.CA CSLB 808104,CO EC8041.Cr HIC 0632D8/ELC 0125305.DC 410 514 0 0 0 0B0/ECC902585.DE 2 0 7112 0 38 6/T1=6032.FL EC73006226.HI CT-29770.IL 15-0052.MA HIC 168572/ EL-1136MR.MD HIC 12 8 94 8/118 05.NC 30801-U.NH 0347C/12523M.NJ NJHIC#13VH06160600/34EB01732700.NM EE98-37959Q NV NV20121135172/C2-OD78648/B2-0079719.OH EL.47707.OR CB80498/C562.PA HICPA077343,RI AC004714/Reg 38313.TXTECL27006.Ur 8726950-5501.VA ELE2705153278.Vr EM-05829.WA SOLARC•91901/SOLARC905P7.Albany 439,Greene A-486.Nassau H2409710000,Putnam PC6041.Rockland H-11864-40-00-00.Suffolk 52057-H.Westchester WC-26088-1,173.N.Y.0#2001384-0CA SCENYC_-N.Y.C.Licensed Dectriclan.#12610.#004485.155 Water St.6th FI..Unit 10.Brooklyn.NY 71201.#2013966-0CA All loans provided by SolarCity Flnance Company.U.C. CA Finance Lenders License 6054796.SolarCity Finance Company.LLC Is licensed by the Delaware State Bank Commissioner to engage In business In Delaware under license number 019422,MD Consumer Loan License 2241,NV Installment Loan License IL11023/IL11024.RI Licensed Lender#2083103LL.TX Registered Creditor 1400050963-202404.Vr Lender License#6766 r7bG// Town of Barnstable *Permit# Regulatory Services wee Regulatory monthajrom issue date t BABNSTABLE, • MASH& Richard V.Scali,Director o '35 ,- 1639. � Building Division POESS Paul Roma,Building Commissioner JUL 2 5 2016 200 Main Street,Hyannis,MA 02 I I,V nr www.town.bastable.ma.us rn O F BA R Office: 508-862-4038 'U Fax:P501$1790-6230 EXPRESS PERMIT APPLICATION - RESIDENTIAL. ONLY r I f Not Valid without Red X-Press Imprint Map/parcel Number J Property Address ( oZ c an (os L IJ Residential Value of Work$ fa ��.'g Minimum fee of$35.00'for work under$6000.00 Owner's Name&Address P F_ ( t—o j�zb j 1 t S (--0 l� Contractor's Name 1/1/9 0 K, t Z 0-6 IUT-2. 1 MC- Telephone Number S_0� 64� S�S� Home Improvement Contractor License#(if applicable) /U 7Q-9 Email: 9G D //Z _ 46 L-C6W Construction Supervisor's License#(if applicable) [gWorkman's Compensation Insurance Check one: ❑ I am a sole proprietor I am the Homeowner ' I have Worker's Compensation Insurance Insurance Company Name t2T� Workman's Comp.Policy# UJ G 3 3 Z3 la Copy of Insurance Compliance Certificate must accompany each permit. Permit Request(check box) Eq Re-roof(hurricane nailed)(stripping old shingles) All construction debris will be taken to Rc-r—AC-5 rEP,444W,rG.,14 ❑Re-roof(hurricane nailed)(not stripping. Going over existing layers of roof) ❑ Re-side ❑ Replacement Windows/doors/sliders.U-Value (maximum.32)#of windows #of doors: ❑ Smoke/Carbon Monoxide detectors 4 floor plans marked with red S and inspections required. Separate Electrical&Fire Permits required. *Where required: Issuance of this permit does not exempt compliance with other town department regulations,i.e.Historic,Conservation,etc. ***Note: Property Owner must sign Property Owner Letter of Permission. A copy of the Home Improvement Contractors License&Construction Supervisors License is required. SIGNATURE: Q:\WPFILES\FORMS\building permit forms\EXP d ' 06/20/16, s The Camwo2"veah*qf-Masstdruswft SrN Depwtwent-af ladustri !'Accidents vil we-ofFiDWS69atrfrrs Boston,MA 02111 -- wrPmmasxgov14Fza We lkere Con2pensatran Insurance Affidavit SmldersiCantracturs/ElectrxiansiPhEmbers Alit Infarmafaan Please Print fly Nsme(B ih 6 ra / TZ C 6 V� AL e , Citgf tatP1 ML4-L R o L n4►q, b2zjk. Ph CIS Are you an employer?Checkthe appropriate bom Type of I am a general contractor and I project(required)--, I. I a>g a employer u�itll * #rave hired the sub�aaitFacbors 6- ❑New oars on employees(fall an dfor part-lime). 2.❑ I am a sole proprietar.or partner- listed on the attached sheet. 7- ❑Remodeling ahr p and have no employees Them sub-contractors have g_ ❑Demolition. employees andhave wot�rs', n wos�g forme in any rapacity_ r 9..❑B,uildiag addifiion [No wpm' Comp-ifevis=e comp_mertrarerp I - . required-] 5. ❑ We are a corporation and its 10�0 Electrical repairs or adddious 3.❑ I am a homeowner doing all wmk officers have exercised their 1L❑Phnnbing repairs or addzhons myself[No workers' right of esempfion per MGL 1�y i c �d-]n c.152,§1(4�andwehaveno [�Rflofrepass employees.[No woriners' 13_❑other cam-msuranw ] •,dap apg&esv��at deeds 6os�1�ilia SIlor�the sectioabeTa�v i5e¢woa3cea'camp�mfi„�peScgi�dvems[ao� �ldameoarmers who salt sibs af5da�if i�Caw!Ley are damp s1E crate sad thenh¢e aui9de«+*a�++*�z�st snLmit a Hein a�daYit mdi�ng sacFL ICantacOoa that checikt9ds box ma=wed sa addiboBal sheet show the aam,e of the snbcahschtam sad state whether ornotthnse emdties bav employees lfthes rshm mnpIaSaes,dwyn=sry=rmde duw wodEeW c=P-FahcF m -Taman euipi +er fliatis prciuidirng workers'co�pt=rtsrdian unsrirarnce f yr ac}�cmlvFay�ee� $ o�v is iihapr�Ficy artd ja1�site inf omatibm Insmaace Company Name: r Policy 4 m Self-ins.Ii '�S f S �3 Z ExpirationDaie: " 57— / - / 7 Job Site Adds /a /J!S Azo PS L A-) Cify/StaWZe p: ,(J/ Attach a-copp of the warlmre compensaflonpolicy decoration page(showing the policy nuatter and expiration date). Failme to serum coverage as required.udder Section 225A of M-GL c_1572 can 1wd tQ the imposition of criminal penalties of a hue up to$UOD OD andl'or orie geaic impdsonmenl�as well as ri it penalties in the form of a STOP WORK ORDER ands fine of up to U_OO a day against the violator_ Be w hised tuna a copy of this statement maybe forwarded to the Office of Isve6dga#ions of the DIA,for instnance coverage verificatico- .I afa ltarghy Vander tits pains andpsmaMiu o pedW7 thatffne inf arma#iwj-prop-i&d abm%is!irate and carrect '-2 r-16 PhMM ojftiat axe arnIy. Do not write in finis area,to be cmpfeteed by city or to)M. off rciaL City or Town: Petmiff+iceEnse 9 Issuing A nflmrity(drde one): L Board of Health I RwMmg Dgw1me at 3.C tyffmm Clerk 4.Electrical Iuspector S.Pbmmbmg Inspeeter 6.other Comt oct Person: Mond;9- . 6 i ormation and Instructions �. x hfiLRsac-hase#fs Gebexal maws cbap�M req=es all eurployers to provide Wm ms'sensation far their employees. Pmsaaatto firs Statute,an etrPlayee'is datmed as¢.evezy person in$�e service of mofher under my ca�ant ofbi Y+ empress or implied,Drat or wti� An em7kyg is defined as"an individ A Part=Z ip,association;corporation or of m legal entity,or any two or more of the foregoing magaged in a joint erdpagrise,andmchidmgthe legal segresentat+yes of a deceased employer,or fie receive'or tcnstee of as individual, adi4idual,p tammImp,association or ofherlegal entity,employing eEUploYees- However the owner of a,dwelliag horse having-not more than fhree apart nenfs maid who resides 1heaem,or the occupant oft - dwelling house of another who effiploys pmsons to do make,conch-nrti on or repair worm.on Such dwelling house ar�thereto shall not because of sash employment be deemled to be an employe." or an the grounds or b�dmg aiopmten - a y shall withhold fhe issuance or MCM chapter 152,§25C(6)also states that everysfatE or local IrCeIISII7g gertcY renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant-who has notproduced acceptable evidence of compliance with.the iasu =coverage ragaked." AddiiionaIly,MCA.chapter I52,§25C(7)states-Nmfherthe cm= qwcan nor any ofits political subdtvisians shall E:h into any cantiact forthe pMfMManoe ofpublic woll-untj acceptable,,evidence of compliancewn the insm--Mce-. requironien s of tuts Chapter have been presenfMd fn the contacting ardhoi *_" Applicants Please fa o-at ac worlo:as'compensation affidavit completr.- .by chec-.kg$e boxes-dLat apply to your dftlafion and,if nmesszmY:s-o*PPh' s)name(s), addresses)and Phone uumber(s) along with their cetdicate(s) of hi=mce. Limited Liability Companies(LLC)or Umted.Liabr7ity Parinesshrps(LLP)ono employees other than the members or paztneas,are not req=rd to easy workers' compensation imam ce- If an LLC or LLP does have employees,apolicyisregnired. Be advised that this affidayit maybe sabmiffedto the Departmentof Industrial Accidents for confirmation of insnz'ance coverage Also be szre to sign and date the afiida The affidavit should be retnmed to 1he city or town that the application for the permit or license is being request not the Department of Ldnsfrial 1A_cddemts. Shouldyou have any gnestims regardnig the law or ifyon are regosedto obtain a wormers' compensation,policy,please call the Departozent at f3ie number listed below. Self-insured em3panies should enter their self-filsarm=license nmnbes an.the appropriate line. City or Town OfEicials S Please be sure that the affidavit is c amplete and printedlegihly. The Department has provided a space at the bottom of the affidavit for you to fill out is the event ibe Office of Invest:gain n s has to coz ict young the applicant_ Please be stye to f ll in the penmhllicense number which will be used as a refe=ce number In addition,an applicant fhat must submit m.Zrttiple PCMIW icense applications ia.any given year,need only sobmrt one affidavit indicafmg ctm eut policy information 1f necessary)and vnde"Job She Q d 1�Tess"fie applica�should write"all locations in (citY or .� o ed or m micrd the city or town may be provided m the town_ A of fficiallysfaurp by SPY applicant as proo-fthat a valid affidavit is on file for f 3fm parr#-.or licenses A new affidavitmust be filled out each any busncss or commercial v year.Where a home owner or citizen is obtaining a license or permit not relaind in �re (ie. a dog licsense or peanrt to bum leaves etc.)said person is NOT xcgakcd to completethis affidavit The Of of Inns would hlo—,to teak You m a.dva ace for your cooperation and should yom have any questions, please do nothesita±e to give'm a call- The Departmenfs address,telephone and fax number: Thy CbWMWVM1ffiE Of Masmchnszem DeparfmWt c6f hi&stcM Aocidmt% Of =of 1nVe&tk. -Ati= B.o lA 02111 Tel.4 617' -4900 Q�E 4-06 or 1-977-Ma S&� Fax 9 617`27 7M Kevised424-07 gmas54pv . k y �%E Town of Barnstable Regulatory Services IU Mt Richard V. Scali,Director ►`� i Building Division. Paul Roma,Building Commissioner 200 Main Street,Hyannis,MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 Property Owner Must Complete and Sign This Section If Using A Builder I ,as Owner of the subject property hereby authorize !'fie r2 liZ (?,0A)7/ aULJ to act on my behalf in all matters relative to work authorized by this building permit application for. (Address of job), **Pool fences and alarms are the responsibility of the applicant Pools are not to be filled or utilized before fence is installed and all final . inspections are performed and accepted. Signature-of Owner Signature of App Print Name Print Name T Date t QYORMS:OWNERPERVIISSIONPOOLS Town of Barnstable Regulatory Services oxt Richard V.Scali,Director r Building Division ELMMsTAIM Paul Roma,Building Commissioner aznss. 019. 200 Main Street, Hyannis,MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 HOMEOWNER LICENSE EXEMPTION ! Please Print DATE: JOB LOCATION: number street village "HOMEOWNER": name home phone# work phone# CURRENT MAILING ADDRESS: city/town state zip code The current exemption for"homeowners"was extended to include owner-occupied dwellings of six units or less and to allow homeowners to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor. DEFINITION OF HOMEOWNER Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two- family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a.two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. (Section 109.1.1) The undersigned"homeowner"assumes responsibility for compliance with the State Building Code and other applicable codes, bylaws,rules and regulations. The undersigned"homeowner"certifies that he/she understands'the Town of Barnstable Building Department minimum inspection procedures and requirements and that he/she will comply with said procedures and requirements. Signature of Homeowner Approval of Building Official Note: Three-family dwellings containing 35,000 cubic feet or larger will be required to comply with the State Building Code Section 127.0 Construction Control. 4 s HOMEOWNER'S EXEMPTION The Code states that: "Any homeowner performing work for which a building permit is required shall be exempt from the provisions of this section(Section 109.1.1 r Licensing of construction Supervisors); provided that if the homeowner engages a person(s)for hire to do such work,that such Homeowner shall-act as supervisor." Many homeowners who use this exemption are unaware that they are assuming the responsibilities of a supervisor (see Appendix Q,Rules&Regulations for Licensing-Construction Supervisors,Section 2.15) This lack of awareness often results in serious problems,particularly when the homeowner hires unlicensed persons. In this case,our Board cannot proceed against the unlicensed person as it would with a licensed Supervisor. The homeowner acting as Supervisor is ultimately responsible. To ensure that the homeowner is fully aware of his/her responsibilities,many communities require,as part of the permit application,that the homeowner certify that he/she understands the responsibilities of a,Supervisor. On the last page this issue is a form currently used by several towns. You may care to amend and adopt such a form/certification for use in your community. Q:\WPFILES\FORMS\building permit fonns\EXPRESS.doc 06/20/16 4A/t Mr. Peter Ford 12 Bishops Ter. Hyannis,. Ma. 6-5-2016 Enclosed please find a proposal for roof replacement at. the abovE General Use tarps to protect the house and grounds Remove all existing roofing materials from the house, breezeway Remove all debris to a qualified disposal site n-stafl = 30 year rated architectural :style aM1sphalt roofing shingle aa- 'Certai brand - colon of choice at 3' of ice and water membrane along the eaves and 18" in the vall #15. felt tarpaper under the rest 8" white aluminum drip edge along the eaves and 5" along the ra New aluminum vent stack flanges New ridge vent 6 nails per shingle - storm nailing Cost: $6500.00 Price includes all necessary labor, materials; permit and fees Payment schedule: 60% down (3900.00 and 40% at finish (2600 Homeowner: Contractor: CERTIFICATE OF LIABILITY INSURANCE UATE(MMIDOYYYY) L.../ 7/11/16 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN'THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is,an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subiect to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: John E Patterson Insurance Agy PHONE FAX 190 Washington Street E-MAIN.L ' (781) 329-1020 AI No: (781) 329-6674 PO Box 36 ADDRESS: INSURERS)AFFORDING COVERAGE NAIC# Westwood, MA 02090 INSURERA:Norfolk & Dedham Mutual INSURED INSURER IS:LibertV Mutual Insurance Compa Moritz Contractors, Inc. INSURER C:LibertVMutual Insurance Com a 15 Hoover Road - INSURERD: Walpole, MA 02081 - INSURER E:' INSURER F: COVERAGES CERTIFICATE N UMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN 1S SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POUCY EXP LTR TYPE OF INSURANCE POLICY NUMBER MMOACY1 MM/DD/YYYY LIMITS A GENERAL LIABILITY R0205927 2/6/16 2/6/17 EACH OCCURRENCE $ 1 OOO' OOO X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED ce PREMISES(Ea occurren $ 50,000 CLAIMS-MADE a OCCUR ME EXP(Anyone person) $ 5,000 PERSONAL&ADVINJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GENT AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OPAGG- $ 2 000 000 }{ POLICY , CT T LOC $. A AUTOMOBILE LIABILITY 91021448A 2/7/16 2/7/17 ESTc.d r,)INGLELIMIT $ 1. 000 OOO - ANYAUTO BODILY INJURY(Par person) $ ALLOWPED X SCHEDULED AUTOS AUTOS n BODILY INJURY(Per accident) $ NON-OWNED PROPERTY DAMAGE $ HIREDAUTOS _ AUTOS P.,.. ent $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESSLIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ C WORKERS COMPENSATION WC5-313-332366 5/1/16. 5/1/17 WC STATU- OTH- AND EMPLOYERS'LIABILITY R ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N N/A E.L.EACHACCIDENT $ 100,000 OFFICERMIEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ '100,000 Ues,describe under SCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ SOO.,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Renerks Schedule,if more space is regui red) -mail: egore@falmouthmass.us. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF-THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED .IN Town of Falmouth ACCORDANCE WITH THE POLICY PROVISIONS. Inspectional Services 59 Town Hall Square AUTHORIZED REPRESENTATIVE Falmouth, MA 02540 John M. Patterson, CPCU ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD Phone: Fax: (508) 548-4290 E-Mail: Massachusetts vepXtrneP at Pub is Ic Board of Building Regulations and Standards License: CS-02W6 Construction Supervisor 1,'=y EDWARD C MORITZ v 1-5 HOOVER RD y� WALPOLE MA 02U81 Expiration: Commissioner 09/11/2017 //+��"citr�itr•ierr[xrt/�r//^.�ln a.�rr��fl.,5 `_.._ _...-__..---.--__._-__,.____.-��_....- _._____...�_.__....:_._,.--..._ .� , Office of Consumer Affairs&Rusihess Regulation license or registration valid for individul use only Ol{27E;1Ta1PRO'CMi=NT CCUNTRAE iOEs °-afore the expiration dite, If fr�und return w: Type. Office of Consumer Affairs and-Business Regulation egistration: 107729g FEU expiration: 8/a/2015 Private Corporr;i�ei ' 10?'ark Plana-Suite 5170 r ;> Boston,MA 02116 MORITZ CONTRACTOR INC.: Edward Moritz t . 15 Hoover Rd Walpole,MA 02081 Unde=secretary — — --_._ Not valid without signature TOWN OF BARNSTABLE BA"ST"LE, i apY��e�� BUILDING INSPECTOR APPLICATION FOR PERMIT TO 6. 0 ZUCT 6 0� E .. ............................................................................................... TYPEOF CONSTRUCTION ..................................................................................................................................... .........�...........��...................19215 I f TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to' the following information: Location ................. 50 �t12� �1—= �/ /v/✓I.S f................................................................................ ProposedUse ............................................. .. .................. ... ..................... ........ ..... ZoningDistrict ........................................................................Fire District .....................,.p....................................................... Name of Ownerv� CW101'047� /� Po'/ //s Address �........ t-lZ.� C�� iYil ............................ .........../........... .. Name of Builder ... .IE.��!.... '.. . 1. 1/7Ld /�.�r .... .. ..............Address .........................................�....... .. . ....��. ........... Nameof Architect ..................................................................Address .................................................................................... Number of Rooms ..............Foundati ......L �8 �` ................ -. . ............................... Exterior .®.. ........�....1-1/n.. TC � ...Roofing .. � � .....SJ-�� ..........:....... �!��.0 C.... ........ ........ Floors w00� �) LB,C�T ���'E. ...Interior ................. . ......... ............. . ......... ................................................................... , i Heating l- Y.-!/ /2 ..............................................Plumbing j� Fireplace ................P46............................................................Approximate Cost ........................................................ Difinitive Plan Approved by Planning Board ________________________________19-------- - Diagram of Lot and Building with Dimensions _ ' 3 � / 7_3 SEPTIC Z STUM JST INSTALLED M COMPLIANCE WITH ARTICLE II STATE SANITARY CODE y1VT) TOWN i r I 144 1.. I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above construction. Name ....:... .. e. ��' w~ Caoljoan ` Pao[� ( ' ' \ ��� eze No ����~~ Permit for ~�~ ~~- & to _ --.. . , 12 Terrace Location --'-����.��...------ .... `T'7 �—' ' Hyannis ........................................................... � \ ( Paul Car]�man— ' Owner ----_----- ----------'' ' ` Typd- of Construction .........�ra.me...................... / r~/ ' -----.--------.------------. � P|c^ ............................ Lot ---.#------� ' ^ - ' D�� I� � Permit Granted --- w�u----.-----.]g �_ ' Date of Inspection lV o��e6 ����~..~ Completed . . � / ^ � ' ~ ' PERMIT REFUSED —'--..�----------------.. 19 / � . ' ^ --------~—'---------------^— ' —.----.—.—.---..---.—.--------.. '---'----------^''~'~—~--'----^` ' , \ ---.—.a---.—.--.------,...........— � ^ . � ' . Approved ~_--------'-----. lg ' � ' | --------------------^^—''---' ` | � ' -------------------''':----^^'' | � I ' SolarCity Date: July 5, 2016 TO: Barnstable Building Department 3 200 Main Street Hyannis, MA 02601 From: SolarCity Corporation Cape Cod Warehouse Z RE: 12 Bishops Terrace, Hyannis Permit No.: BP B-16-64 t rn Our Job No.: 1B-0262554 i D Note: t Please extend the Building& Electrical permits for this address,which issued on January 28, 2016. , A check for$50.00 is enclosed. Please contact me directly with any questions/concerns. Thank you. CheryCX. Gruenstern Cheryl Gruenstern Permit Coordinator Direct Line: (508) 640.5397 cgruenstern@solarcity.com d p 112 Great Western Road,South Dennis,MA 02660 T (888)SOL-CITY solarcity.com At 05500.AR M-8937.AZ ROC 24377VROC 245450,CA CSL8 888104,00 EC8041,CT HIC 0632778/ELC 0125305,DC 410 514 0 0 0 0 8 0/ECC902585.DE 2 01112 0 3 8 6/T1-6032.FL ECTS006226.HI CT-29770,IL 15-0052.MA HIC 168572/ EL-1136MR.MD HIC 128948/11805.NC 30801-U.NH 0347C/12523M.NJ NJHIC#13VH06160600/34EB01732700,NM EE98-379590.NV NV2012M5172/C2-0078648/B2-0079719.OH EL.47707,OR CB780498/C562.PA HICPA017343.RI - AC004714/Reg 38313,TXTECL27006,UT 8726950-5501.VA ELE2705153278,Vr EM-05829,WA SOLARC•91901/SOLARC•905P7,Albany 439,Greene A-486.Nassau H240971000Q Putnam PC6041.Rockland H-11864-40-00-00,Suffolk 52057-H.Westchester WC-26088-H73.N.Y.0#2001384-0CA.SCENYC:N.Y.C.Licensed Electrician,#12610,M004485.155 Water St.6th Fl..Unit 10,Brooldyn.NY 11201#2013966-DCA All loans provided by SolarCl ty Flnance Gompany.LLC. CA Finance Lenders License 6054796.SolarCity Finance Company,LLC Is Il censed by the Delaware State Bank Commissioner to engage In business in Delaware under license number 019422.MD.Consumer Loan License 2241,KV Installment Loan License IL11023/I1.11024.RI Licensed Lender#20153103LL,TX Registered Creditor 1400050963-202404,Vr Lender License#6766 4 T(�WN OF BARNSTABLE BUILDING PERMIT APPLICATION Map Parcel c;Xp Application# ' Health Division Date Issued Conservation Division Application Fee Planning Dept. Permit Fee Date Definitive Plan proved by Planning Board KH y Historic - O _ Preservation/Hyannis Ab Project Street Address I ero'a-.e Village Owner Te A-o- C }ur Address G/ M rLJ Y �1 Telephone `�• a 3 o�D �' (��UGf �ufe tJ�cC Permit Request Aye(5 oy\ ('zj , i ome Y-,v%J P"eS Square feet: 1 st floor: existing — proposed 2nd floor: existing proposed "total new Zoning District G-� Flood Plain -ter Groundwater Overlay Project Valuation Construction Type K�? Lot Size Grandfathered: ❑Yes ,;-No If yes, attach supporting documentation. Dwelling Type: Single Family k Two Family ❑ Multi-Family(# units) Age of Existing Structure 5 • Historic House: ❑Yes ,1!51.No On Old King's Highway: ❑Yes JtXNo Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑Other Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing new Number of Bedrooms: existing —new Total Room Count (not including baths): existing -new First Floor Room Count ._. Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other Central Air: ❑Yes ❑ No Fireplaces: Existing /QrNew Existing wood%coal stove❑YeS ❑ No Detached garage: ❑ existing ❑ new si*ltPool: ❑ existing ❑ new size Barn: ❑ existing ❑ new o izeAO- Attached garage: ❑ existing ❑ new si _Shed: existing new size�#� Other: E- Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes *No If yes, site plan review# Current Use tS-det? Proposed Use Wh APPLICANT INFORMATION (BUIL R OR HOMEOWNER) AName 1?o� Telephone Number Address 9 L� S C License # C.S tow(9 is vit1�5 (rk�Ja($IoC� Home Improvement Contractor# Email (2 M'r-0St5N &A-�JY- G Worker's Compensation # 4 ALL Cd TRUCTION DEBRIS RESULTI FROM THIS PROJECT WILL BE TAKEN TO C u t i�d Cvt C1 - SIGNATURE - DATE a.h, -a-6 aro t k. FOR OFFICIAL USE ONLY f APPLICATION # DATE ISSUED MAP/ PARCEL NO. A'6�DRESS VILLAGE OWNER DATE OF INSPECTION: FOUNDATION i FRAME INSULATION FIREPLACE t ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL FINAL BUILDING O 4 r DATE CLOSED OUT ASSOCIATION PLAN NO. I SolarCo..,, OWNER AUTHORIZATION Job#: 3Z_?<; -. Property Address:_I Z. g i5 rans 'f tf cr n j,k¢.A bz o f Owner of the subject Property hereby authorize SOLARCTTY CORPORATION to act on my behalf, in all matters relative to work authorized by this building permit application. J Signature of Owner. 174 Date: 'F N II , F x �� 4 ��i•� i� ._;.c., i Mataathus�ts Qgi �ItgM fit hs:tlliC,ia�� '�► Oaorra of Rurkhnq AspuAstro�iF��C"Jifnuarrro. •toilov CS-108615 JASON PATRY 821 STEWART QRWE Abington MA 02151 _ %L..bdre�c. i.q+ref W w � 02/08l20t8 t it *-- OmetarCouamtrAffain&DosinmRstslslioa HOME IMPROVEMENT CONTRACTOR l + Registration: 166M TYRery�ry ` Expiratian: UM017 SuOWemom C SOLAR CITY CORPORATION I JASON PATRY i 24 ST MARTIN STREET BLD 2UNI RMBOROUGH,MA 01752 tlodersarerarq 7) n,«�>rt< r�rcrt' . c Office of Consumer Affairs d Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: .168572 Type: Supplement Card SOLAR CITY CORPORATION I• Expiration: 3/8/2017 CHERYL GRUENSTERN . 24 ST MARTIN STREET BLD 2UNIT .11 MARLBOROUGH, MA 01752 .. - -- - -------.-------•------_,.. .. Update Address and return card.Mark reason for change. sCq i 0 orw-Z ; Address Renewal Employment Lost Card --'Office of Consumer Affairs&Business Regulation License or registration valid for individul use only MOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: h Office of Consumer Affairs and Business Regulation . Registration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/8/2017 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION CHERYL GRUENSTERN c , 3055 CLEARVIEW WAY SAN MATEO,CA 94402 . . - �:'._l�'st f' �,w,,_.t,4.:_sta,t t•c,.�.,.__-- Undersecretary, -Not valid without signature t I • Ill Commonwealth of Maswchiadits Deparimatt o,f Induslrral Accidents 1 Congress Street,Sane 100 Boston,MA 02114--2017 1V"W n=s gov/dia Workers'Compensation Insurance Affida4rit:Builders/Contractors/Electricians/Plumbers. TO BE RILED WITH THE PERMrrfING AUTHOI ITY. AnnticantInfnrmatiatt Please Print Lab ty- NaM(Bus1nmw'0rgunimrwnAndividtW): SalarCity Corporation Address: 3055 Ctearview Way City/Staie/Zip: Sari Mateo,CA 94402 Ph©ne#: (888)785-24$9 Are you an employer?Check the xppropriatr box: Type of project(required): 1.0 l am aemployer with 15,000 loyces(rigI aodior partdiine). 7. 0 New COItsts'uGtiotl Z❑1 am a sole proprietoror parlaersbip and bava no employes worker.for nx:in a. E]Romodeling any .t apachy.[Na%urbess'comp.insurance required.] 3.(J1 am a homeowner doin'all wok rrgsdC[Noworkws'comp,insuranceYequimd.l t i10 9. p Demolition 4.�1 am a lronzowner wed will behieirtg arntraelars W eortdttd all tt?Ot1t on my property t will Building addition cnsorc that all rmdractors aWW have>sorirers,'t ornpensalion irsuranco or are sole 11.(]Eledt'ieal tepairs or additions proprietors Wth tut csttploydxs. 12.[]Plumbing repairs or additions So 1 am a gencxai,comractor end I have hired dresub-contractors lWcd on the attached sheet. 13.❑Roof repairs These Mtb-ooniractots haveemploym and have workers'comp,insuraaae 6.[J We are a corporation and its officers have exorcised their right of axampt$m per MGL c. 14.DOtitet'sctiar pounds 13Z§1(4),and we have wemployces,[No wadmis'emnp.insutanccregol") May applicmit that chocks box 91 oddest also all out dxe smlion below showing their vv-orlews'compaw ion policy information. t 1 tomeowneas*v1 o submit this artidwit indicating they are doing all wort:and then hire outside.contractors mast submit a new attidavit indicating such. korrlraCtors that chock this box moat nun abed an additional sheet showing the note of the sub-emdtaulm axed slate wheiher to txx those entities have engftyaas. If the sdb-mmtractors have cusployees,they most provide their workers'commp.policy manwr. 1 art ats employer/lust is providing workers'eonrensatlon Ursaranee for ray empfoym Below is the policy rend job site ixformcrtaan. Insurance Company Name:Amertcan Zurich Insurance Company Policy#or Self ins.Lic.h: WC0182015-00 Expiration Data:: 911/2016 Job Site Address: 12 Bishops Terrace Csty/Statc/ZipHyannis,MA 02601 Attach a copy of the workers'compeosati m policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required tender MGL c.152,§25A is a crtmimal violation punishable by a fine up to$1,500.00 and/or one-year imprisontmetl,as well as civil penalties in the form of STOP WORK ORDER and a tine of up to 5250.U0 a day against the violator.A copy of this statement may be forwarded to the Office of investigations of the DIA for insurance coverage verification. I do hereby eerti molder the pains and penalties of psrjury dour the heorinmion provided above Is True and correct ason Patr : JanuaEy 20, 2016 a heist use on(y. Do not write in this area,to be completed by city or town offlddL City or Town: PennitfLicense# Issuing Apthority(circle one): 1.board of Heaalth 2.Building Department 3.City/Town Clark 4.Electrical Inspector I Plumbing Inspet:tor 6.other Contact Person: Phone#: I - AC R!� DATE JURMNYM `� CERTIFICATE OF LIABILITY INSURANCE 08/1712015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemont(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES ---._..._...._..._._._.... ._........ .._...... T.-- 346 CALIFORNIA STREET,SUITE 13 PHONE 00 F! 1c CALIFORNIA LICENSE NO.0437153 E4IAIL -.._.. . . ...._..........:... .. .__. ! SAN FRANCISCO,CA 94104 A4RREs :.......... .._....__.._....__...-...—— _....---- Attw Shannon Scott 415.743-8334 1N9URER(6)AFFORDINOCOVERABE-...• - ..-._....,- NAICg 998301-STND-GAWUE-i5-16 INSURER A;ZurichAmericanlnsuramCompany ! 1i6535 INSURED INSURE m.NZA_..-..__...................._.. ._. ._....._.....- ..._.. .. ..._._ 'NIA Sdw3065CJIy Corpnhaw Way INSURER C:NIA N/' A — 3065 Clearview.Way .......... ............. San Mateo,CA 94402 .. • B�g�ER D;American Zurich llauwltce Company •40142 RdSDREIt E INSURER F: COVERAGES CERTIFICATE NUMBER. SEA-002713V"S REVISION NUMBER:4 THIS 1S TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAWS. rA$t1LTS'U., POLICY EFF POUCYEXi — L7Tt, TYPE OF INSURANCE POLICY NUMBER Mh1w LIMIFS A X 'COMMERCIAL GENERAL LIABILITY GLOO182016-00 6910112015 091012016 EACH OCCURRENCE $ 3.000:000 DAMAGE C D RF _..._.. .-......_ .... l iClAIM6•AIADE OCCUR PREMI$E,S{Ca• urt�nC¢],,, 5.,,,...._.__._ 3;00O,090 X Silk 5250,000 I MED EXP(Airy one.person).... $.... _........_._— 5,000 PERSONAL&ADV INJURY 5 _. 3,000,pD0 GENTL AGGREGATE LIMIT APPLIES PER: - GENERAL AGGREGATE S 6,000.0m t'OLICY J C �... LOG PUGfS:CO PRDMP1pPAGG 5 _ _......_.... 6,000_000 .._ OTHER. { -. .. S A Auros oux LlAmurf MP0192017.00 091NIM5 10SM1016 COMBINED SINGLE LIMIT S 5,600,000 X ANY AUTO I BOOp-Y INJURY(Per person) S X ALL OWNED X. SCHEDULEDAUTO AUTOS BODILY INJURY(Per accident) S X HIRED AUTOS ,X... A N S'M�IED I f i PRO OBp(ZTY DAMAGE_......... $ COMPICOLL DED: 3 $5 0g0 UMBREiLA LIAR OCCUR ! EACH OCCURRENCE S - Ht • EXCEBSLUIB CLAIMS MADE i AGGREGATE S OED i RETENTIONS S D WORKERS COMPENSATION jWC0182014-M(ADS) 091012015 1091012016 X R o w T97�T€_ ._., . ANOEMPLOYE,RS!LIABILITY -. _ _._.....__._ A l��OPRIIETORMARTNERIEXECtITl1lE YIN DEDUCTIBLE15-00 I5500,00D DW015 OSalra6 E.L EACH ACCIDENT — s _ 1,000.0m tmy DESCRIPTION OF below ! E L.DISEASE-OUCY LMArT S 'c Or-ncEIzAWMAER t xCLUDED? i 1If es,describe under I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES IACORD f9f,Addiflonal Remarks Schedule,may be RHaahod It more space Is requiredl - - Evidence of Inunance. CERTIFICATE HOLDER CANCELLATION SdarQy CoTporalian SHOULD ANY OF THE ABOVE DESCRIBED POLICIES 8E CANCELLED BEFORE 3055ClearviexWay THE EXPIRATION DATE THEREOF, NOTICE WILL BE DF_L(VERED IN San Mateo.CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRERMATP19 of Marsh Risk&Irmwance Services I Charles Marmolejo 01OW2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD j Version#53.6-Ill . RU �o„SolarCit Y January 19,2016 RE: CERTIFICATION LETTER „ Project/Job # 0262554 � JASON WIL CAM Project Address: Ford Residence Z TOM AN 12 Bishops Terrace 0 STRUCTURALCn HYANNIS, MA 02601 i�Il: 1 AHJ Barnstable0,�• SC Office Cape CodAL �'� /19/2016 Design Criteria: -Applicable Codes= MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf - MP1: Roof DL= 11.5 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL= 21 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.18757 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluationI certify that the existing structure,with upgrades specified in the plans, directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. t Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or'exceed all requirements set forth by the ASCE 7.standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. Digitally signed by Jason Toman Date:2016.01.19-17:27:13-07'00' 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 243771.OA CSLB 888104,CO EC 8041.CT I1I0 0632778.DC WC 71101486,DC HtS 71101488.HI CT-297M MA I i1C 10857Z.MD PAHIC 128948,NJ 1WH061006m, - Oi;CCB IMM98.PA 077343,TX TDLR 27006.WA OCU SOLARC'9190T.1ta 2013 SolarQty AP 0,11 .reserved: I Version#S3.6-TBD 2 " I i RU �N,So a C t y HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 64" 24" 39" NA Staggered 62.1% Portrait Hardware Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 48" 20" 65" NA Staggered 77.5% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP3 Stick Frame @ 16 in.O.C. 220 Member Analysis OK w/Upgrades as Specified in Plans Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 2 43771.CA CSL8 885t04,CO f.CC 8041.CT HIC 0632776.DC H C 11101486.OC HIS 711014M HI.CT-297 70,MA HIC 168572,tdD i.HIC 121s74S,N,1 13M0616U600, OR CCS 180498,PA 077343.TX TDLR 27006,WA CCL_SOL ARC'91207,0 2013 Enlar0ty.All riC)hts reson�ef. f - - ,STRUCTU --RE ANALYSIS - LOADING SUMMARY ANDMEMBER CHECK- MP1 Member Properties Summary MPi Horizontal Member Spans Upgraded Rafter Properties Overhang 0.74 ft Net W 3.00" Roof System Properties San 1 13.67 ft e E uivD. '.. 5.50" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material Comp Roof San 3 A 16.50 in.A2 Re-Roof No Span 4 S. 15.12 in.A3 Plywood SheathingYes Span 5 = r.: : 'n', •I = 41.59 in.A4 Board Sheathing None Total Rake Span 15.54 ft TL Defl'n Limit 120 Vaulted Ceiling No ' PV 1 Start `,'A.33 ft Wood Species SPIF Ceiling Finish 1/2"Gypsum Board PV 1 End 13.58 ft Wood Grade #2 Rafter Slope 220 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End IF, 135 psi Top Lat Bracing Full P,V.3 Start ,'` E ,.f 'x 1400000 psL Bot Lat Bracing I At Supports PV 3'End Emin 510000 psi Member Loading mary Roof Pitch 5 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 11.5 psf x 1.08 12.4 psf 12.4 psf :PV Dead Load PV-DL3.0'psf . x• 1.08 f ., a.r. . 3.2 sf, _ Roof Live Load RLL 20.0 psf x 0.95 19.0 psf Live/Snow Load LL SLl'2 30.0 psf x 0.7 1 x 0.7 21.0 psf 21.0 psf Total Load Governin LC TL 33.4 sf 36.6 sf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(IS)py; Ce=0.9,Ct=1.1,Is=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+S 1.15 1.00 1 0.96 1.3 1.15 Member Anal sis Results Summary Governing Analysis Max Demand @ Location CapacityDCR Result Bending + Stress 899 psi 7.6 ft 1504 psi 0.60 Pass !CALCULATION OF'DESIGN;WIND LOADS--'MP1-- Mounting Plane Information Roofing Material Comp Roof PV,System Type �� SolarCity SleekMount _� . TM ......._.�_.._.. -.-_......_w�.*»x.e:._.�. ......may._. Spanning Vents No Standoff Attachment Hardware Comp Mount Type C *' Roof Slope __ 220 Rafter.Spacing ______' _ ~ _ _16"O.C.__ FramingType Direction Y-Y Rafters Purlin Spacing; : X-X,Purlins.OnlY_. . Tile Reveal Tile Roofs Only NA Tile Attachment System_ � - TMTile-Roofs Only. y NA ,StandingSeam ra S acin SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method _ _ _ _ Partially/Fully EnclosecLMethod Basic Wind Speed V 110 mph Fig. 6-1 Exposure.Category-_- _Section 6.5.6.3 Roof Style Gable of Fig.6-11B/C/D-14A/B Mean Roof Height h.' 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor_ K 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor- "777"' I ._ F, ' '� %°; 1:0 : '"' Table 6'1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient (Down), " GC oow,n P='0.45 S :" Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down P 10.1 Psf .ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape _ 64" 39" Max Allowable Cantilever Landscape_ =24 Standoff Confi uration Landscape — Staggered Max Standoff Tributary Area ,.. Trib PV Assembly Dead Load W-PV —3 0 psf. Net Wind.Upliftat-Standoff - T_actual_- 311 Ibs _ Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity I DCR .,_ €�.;�62.1% X-Direction Y-Direction Max Allowable Standoff Spacing_ Portrait 48" 65" _._Max Allowable.Cantilever� __ Portrait_ _ 20" _ rt- _ NA,_ Standoff Confi uration Portrait Stag ered Max Standoff„Tributary Area" { A> ,,,-,,,,. Trib :' >s" 22 sf PV Assembly Dead Load W-PV 3.0 psf � Net Wind_U_plift at Standoff _ - _. ��T actual _� �� -388�I6s Uplift Capacity of Standoff T-allow 500 Ibs W_ Standoff Demand/Capacity DCR 77.5% - _ Town of Barnstable Regulatory Services �FTNE Tp� Thomas F.Geiler,Director sninvsTABLE. Building Division 9� ,�gMAS& Tom Perry,Building Commissioner 1 Arf 39- A 200 Main Street, Hyannis,MA 02601 www.town.barnstable.ma.us Office: 508-862-4038 Fax: 508-790-6230 Approved: Fee: e Permit#: e pg r1q HOME OCCUPATION REGISTRATION Date: C +- Name: �p 5��" �1--� Phone#: 8CEQ-'9 —k d 1 Address: Village: ` Name of Business:___ ll�s ------------------- Type of Bussiinessz ) —'�_' Map/Lot: INTENT: It is the intent of this section to allow the residents of the Town of Barnstable to operate a home occupation within single family dwellings,subject to the provisions of Section 4-1.4 of the Zoning ordinance,provided that the activity shall not be discernible from outside the dwelling: there shall be no increase in noise or odor;no visual alteration to the premises which would suggest anything other than a residential use;no increase in traffic above normal residential volumes; and no increase in air or groundwater pollution. After registration with the Building Inspector,a customary home occupation shall be permitted as of right subject to the following conditions: • The activity is carried on by the permanent resident of a single family residential dwelling unit,located within that dwelling unit. • Such use occupies no more than 400 square feet of space. • There are no external alterations to the dwelling which are not customary in residential buildings,and there is no outside evidence of such use. • No traffic will be generated in excess of normal residential volumes. • The use does not involve the production of offensive noise,vibration,smoke,dust or other particular matter, odors,electrical disturbance,heat,glare,humidity or other objectionable effects. • There is no storage or use of toxic or hazardous materials,or flammable or explosive materials,in excess of normal household quantities. • Any need for parking generated by such use shall be met on the same lot containing the Customary Home Occupation,and not within the required front yard. • There is no exterior storage or display of materials or equipment. • There is no commercial vehicles related to the Customary Home Occupation, other than one van or one pick-up truck not to exceed one ton capacity,and one trailer not to exceed 20 feet in length and not to exceed 4 tires,parked on the same lot containing the Customary Home Occupation. • No sign shall be displayed indicating the Customary Home Occupation. • If the Customary Home Occupation is listed or advertised as a business,the street address shall not be included. • No person shall be employed in the Customary Home Occupation who is not a permanent resident of the dwelling unit. I,the undersigned,have read and agree with the above restrictions for my home occupation I am registering. Q, Applicant:�=,=:,- �� Date: No`l , ` oolf J Homeoc.doc Rev.5/30/03 TO ALL NEW BUSINESS OWNERS DATE: �:.;. ;. Fill in please: �.M�Mn APPLICANT'S IM YOUR NAME.t2 ' YOUR HOME ADDRESS: BUSINESS TELEPHONE Telephone Number Home 56-7 r NAME OF NEW BUSINESS TYPE OF BUSINESS IS THIS A HOME OCCUPATION? ES NO �< L Have you been given approval from the Yu ivision? YES NO Z 5 k ...- ADDRESS OF BUSINESS 1 t ca r^ MAP/PARCEL NUMBER When starting a new business there are sever Al things you must On order to be in compliance with the rules and regulations of the Town of Barnstable. This form is intended to assist you in obtaining the information you may need. Once you have obtained the.required signatures, listed below,you may apply for a*business certificate at the Town Clerk's Office (Ist floor-Town.Hall). You MUST go to the following office to make sure you have all the required permits and licenses.. GO TO 200 Main St. - [corner of Yarmouth Rd. & Main Street] and you will find the following offices: 1. BUILDING COMMIS NER' FICE This individual has be orme o any permit requirements that pertain to this type of business. F Aut rued Si ature* COMMENTS: J 2. BOA This individual ha b en informed t ermit quire ain o is type of business. ri Signature* COMMENTS: 3. CONSUMER AFFAIRS (LICENSING Fiin& 0This individual ha n info of theents that pertain"to this type of business. Authorized Signature* COMMENTS: Business certificates [cost$30.00 for 4 years]. A business certificate ONLY REGISTERS YOUR NAME in the town (which you must do by M.G.L. -it does not give you permission to operate-you must get that through completion of the processes from the various departments involved. **SIGNIFIES APPRO VAL FORA BUSINESS CERTIFICATE ONL Y. r� 11 r• . `'. ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES f A AMPERE 1. THIS SYSTEM.IS GRID—INTERTIED VIA A . W AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. t CONIC CONCRETE 3. . A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN - EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER - kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST,ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ' ALL WIRES SHALL BE PROVIDED WITH STRAIN F `j (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE - PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION . HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER m VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT x W WATT - 3R NEMA- 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 .STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES •� PV5 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: * • �' AHJ. Barnstable r _ REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: NSTAR Electric (Commonwealth Electric) � 1 r J B-0 2 6 2 5 5 4 00 PREMISE OWNER: - DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: FORD PETER ` FORD RESIDENCE "�'s CONTAINED SHALL NOT EXCEPT USED FOR THE Harold Johnson SolarCit BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount .T e C 12 BISHOPS TERRACE 5.2 KW PV ARRAY A y PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: H YAN N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH r ^ THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR #' TSM-260PD05.18 24 St.Martin Drive,Building 2,.Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE Marlborough,MA 01752 PERMISSION OF SOLARgTY INC. INVERTER: T. (650)611, F: (650)638-1029 ISCLAREDGE SE380OA—USOOOSNR2 (508) 775-7823 ; COVER SHEET PV 1 1/19/201s (BBB)—SOL—CITY(765-2489) winsolarcityaam I F: PITCH: 22 ARRAY PITCH:22 t MPl AZIMUTH: 106 ARRAY AZIMUTH: 106 MATERIAL: Comp Shingle STORY: 1 Story s A Q� JAS014 WIL IAM Z TOMAN In 'STRUCTURAL v Isla.5 i 554 Front Of HouseGem AL /19/2016 Digitally signed by Jason Toman Date:2016.01.19 17:27:25 -07'00' �.p Inv LEGEND AC O (E) UTILITY METER & WARNING LABEL Ins INVERTER W/:INTEGRATED DC DISCO O & WARNING LABELS DC I DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS MIDI DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS R ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS A CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L-"J SITE PLAN Scale: 1/8" = 1' a 0 1' 8' 16, CONFIDENTIAL,- THE'INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCPoP710N: DESIGN: JB-0262554 00 FORD, PETER FORD RESIDENCE Harold Johnson +\'a CONTAINED SHALL NOT BE USED FOR THE ity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMt T C 12 BISHOPS TERRACE 5.2 KW PV ARRAY ��� oar PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: e H YAN N I S M A 02601 ORGANIZATION,EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-260PDO5.18 za St.Martin Drive,Building 2.Unit n SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHE: REV DATE T: (650)6rlb oug Marlborough,MA (6A1752 636-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3800A—US000SNR2 (508) 775-7823 SITE PLAN PV 2 1/19/2016 (8BB)-SOL-CITY(765-2489) www.solorcitycom ' q 2xs SPF 2 (N 1 -�' a JAS014 WIL'I'A TOMAN S1 STRUCTURAL 9'-3 aJa,5 e 554 �g�ic• F�AST1✓��. �' \ 6' END 13'-8" �rf�lVAL DISTANCE (E) LBW /�9/20�6 —16" O.C. TYP.— (E) 2x6 RAFTER SIDE VIEW OF MP1 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDI ATED BY HATCHING 2 4" A UPGRADE NOTES: SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER MP1 IX-SPACING IX-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. LANDSCAPE 64" 1 STAGGERED - 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON.SOW 22300 (IF 2=PLY) OR 22458 PORTRAIT 48" 20" - (IF 3—PLY) SDW SCREWS AS SHOWN AT 16" O.C. ALONG SPAN AS SPECIFIED, IF RAFTER 2x6 @ 16"OC ROOF AZI 106 PITCH 22 STORIES:1 WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A J" DRILL BIT. ARRAY AZI Toe PITCH zz ALT. OPTION FOR FULL LENGTH MEMBERS ONLY— FASTEN (N) SIDE MEMBER TO_ - c.1. 2x6 @16"oc �m Shingle • 2x6. END FASTENER GROUPING. (E) RAFTER W/10d (IF 2—PLY) OR 16d FROM EACH.SIDE (IF 3-PLY) COMMON D 1 NAILS AT 6" O.C. ALONG SPAN. Scale: 1"=1'-O" SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH,THE ARRAY IS LAGGED PV MODULE 5/16" BOLT'WITH LOCK - INSTALLATION ORDER - & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT. (1) LOCATION, AND DRILL PILOT. - ZEP ARRAY SKIRT. (6) HOLE. SEAL PILOT HOLE WITH SIMPSON SDW 22300 WOOD SCRE7OR (E) RAFTER (4) C2)1 POLYURETHANE SEALANT: (E) WALL OR (N) SISTER MEMBER CENTERED (E) RIDGE BOARD ZEP COMP MOUNT C a SUPPORT BELOW . BETWEEN SUPPORTS SUPPORT BELOW _ (3) INSERT FLASHING. . ZEP FLASHING C 3 E SEE MP SIDE VIEW FOR REQUIRED LENGTH L ,. (E) COMP. SHINGLE (1) (4) PLACE MOUNT. Dl MI R Dl (E) ROOF DECKING V (2) ' INSTALL LAG BOLT WITH ; 5/16" DIA STAINLESS (5) G(5) SEALING WASHER. TOP VIEW OF PARTIAL LENGTH SISTER STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH OUI WITH SEALING WASHER (6) Scale:3/4"=1'o" , BOLT & WASHERS. (2-1/2' EMBED, MIN) (E) RAFTER . 1 STANDOFF , CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J B-0262554 OO PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT E USED FOR THE FORD, PETER FORD RESIDENCE Harold Johnson SO�a�C�t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTMC SYSTEM: �.� NOR MALL IT BE DISCLOSED IN WHOLE OR IN y. Comp Mount Type C L1�2 BISHOP�SI TERRCACE 5.2 KW PV ARRAY h� • PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES I I YAN N I S IVI A O2 V O� ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Nartln Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-260PDO5.18 g SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN Q 'Z PAGE NAME SHEET: REV. DAIS Marlborough,MA 50) PERMISSION OF SOLARCITY INC. INVERTER' 5OH 775-7823 PV 3 1 19 2016 T. SOLO)63B-1028 F: SOLO)636-10y8 SOLAREDGE SE3800A-USOOOSNR2 � ) STRUCTURAL VIEWS / / (BBB)—�—CITY -248s) wwwsdarari.wm UPLIFT CALCULATIONS . SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-026 2 5 54 0 0 FORD, PETER FORD RESIDENCE Harold Johnson SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTWG SYSTEM: �.� NOR MALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T e C 12 BISHOPS TERRACE 5.2 KW PV ARRAY ►�� PART TO OTHERS OUTSIDE THE RECIPIENTS NODULES H YAN N I S M A 02601 v ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-260PDO5.18 24 St. Martin Drive,Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV.. DATE T: (650)638—028 A F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE380OA-USOOOSNR2 (508) 775-7823 UPLIFT CALCULATIONS PV 4 1/19/2016 (e88)-SOL-CITY(765-2489) wwwsdarcity.can .= GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER.SPECS MODULE SPECS LICENSE. BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: INV 1 -(1)SOLAREDGE E ## SE3800, 97.5 OSNR2 LABEL: A -(20)TRINA SOLAR ## TSM2360P PTC, 2298426 Tie-In: Supply Side Connection Inverter; 380OW, 240V, 97.59a W/Unifed Disco and ZB,RGM,AFCI PV Module; 260W, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isa AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER-HAMMER Inverter 1 Disconnect CUTLER-HAMMER 10OA/2P 3 Disconnect 2 SOLAREDGE A 20A SE3800A-LIS000SNR2 B L2 -- - N 1 . (E) LOADS GND EGC/ DC+ - L: - DC+ - - M - --- GND ------------------------- ---GEC LO T N DC- - 4bC MPI: 1X2OGNDEGC -- --- ----- -,------ EGC------------- -t-lol- � c EGC/GEC y I I _ _ GEC TO 120/240v SINGLE PHASE UTILITY SERVICE I I I I • PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP - POI (2)Gro qd Rod A (1)CUTLER-HAMMER #DG222NR8 PV (20)SOLAREDGE �300-2NA4AZS Sr8 x 8, C per Disconnect; 60A, 24OVoc, Fusible, NEMA 3R AC PowerBox Optimizer, 300W, H4, DC to;DC, ZEP : DC' (2)ILSCO�I IPC 4�O-#6 Insulation Piercing Connector; Main 4/0-4, Top 6-14 B (1),CUTLER-HAMMER #DG221UR6 nd (1)AWG#6, Solid Bare Copper Disconnect; 30A, 240Vac, Non-Fusible, NEMA 3R SC SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE -(1)CUTLER- AMMER DG030N6 _(1)Ground Rad; 5/8" x 8'. Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Ground�Neutral t; 30A, General Duty(DG) r (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE•REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 1 AWG #6, THWN-2, Black 1 AWG#10, THWN-2, Black (2)AWG #10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O (1)AWG#6, THWN-2, Red O (1)AWG#10, 7HWN-2, Red O cOO (1)AWG #6 Copperp . p= (1)AWG#6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1)AWG#10. THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1 Conduit Kt;.i Oar EMT EGC Vm =350 VDC Im 14.66 ADC . . . . . . .-(1)AWG 16,•Solid 8are.Copper_ GEC. . • -(1)Conduit.Kit;.3/4'.EMT. . . . . .. . . . . . • • . . .-(1)AWG#8,•THMN-2,•Green • • EGC/GEC-0)Conduit.Kit;•3/4"•EMT. _ . • • • • • . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-0262554 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE FORD, PETER FORD RESIDENCE Harold Johnson �g�f, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 4o SolarC•�t NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12 BISHOPS TERRACE `5.2 KW PV ARRAY h. PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES:- H YAN N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION NTH � 24 St. Martin Drive,Building 2,Un-it THE SALE AND USE OF THE RESPECTIVE (20) TRINA SOLAR # TSM-260PD05:18 SHEEL REV DATE Marlin Drive, MA ing 2, SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T: (650)636-1028 R (650)638-1029 PERMISSION OF SOLARCTY INC. SOLAREDGE sE3sooA-us000sNR2 (508) 775-7823 THREE LINE DIAGRAM PV 5 1/1s/2o1s (Bee)-soL-CITY(765-2489) w�w,sa,aralty.aam r. Label Location: Label Location: Label Location: (C)(CB) �j (� (AC)(POI) o (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 0 o I o o C7 NEC 690.17.E a .o so NEC 690.35(F) Label Location: o► =o o - o ° o • TO BE USED WHEN (DC) (INV) o•D a �j�: - o -o e o • o INVERTER IS D O Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: o 0 MEW W (POI) us w- o - (DC) (INV) - o 0 0_ Per Code: -° Per Code: •-o n o 0 o NEC 690.17.4; NEC 690.54 -o - NEC 690.53 :o s o•o io I, �rj • n o- - o- a -o 0 Label Location: IAl (DC) (INV) _ Per Code: OPP• -o o (© o o NEC690.5(C) Label Location: eaw (POI) -o o s • o 0 Per Code: NEC 690.64.B.4 - o 0 0 • MM Label Location: W� (DC) (CB) e _n Per Code: Label Location: 0 0 0 o NEC 690.17(4) (D) (POI) Per Code: °• �i;l l o1000 NEC 690.64.6.4 0 0 -o s e Label Location: o (POI) Per Code: Label Location: o - ° NEC 690.64.B.7 AC POI o° o - o • (AC): AC Disconnect D O Per Code: °o (C): Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect (AC) (POI) - (LC): Load Center Per Code: (M): Utility Meter mamma NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED =��4�I 3055 ClearviA Way - San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �•.►•• T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (888)-SOL-CITY(765-2489)www.solarc4.com wattit SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o F ''SOlafClty ZepSolar Next-Level PV Mounting Technology '�'SOIr3fClty ZepSolar Next-Level PV Mounting Technology Zep System � - Components ® � f for composition shingle roofs art ���� _ � • a .:- Leveling Foot .Orourtd Zep Interlock (Keyskle shown) . ~, Part No.850-1177 - ,_ ,_.,,:. --•— -- ETL listed to UL 467 r . . - Zep Compatible PV Module i . Zep Groove .. .. - ' < <. .:.. :... ... Real Attachment A,-y Skirt - _ - t ,`comp Mount ,.,,�•,� _ -.r • � 1 Part No.850-1382 e Listed to UL 2582 - Mounting Block Listed to UL 2703 h �o 'n Description - - � - • / PV mounting solution for composition shingle roofs FA m Works with all Zep Compatible Modules MEN" MNPk<` Auto bonding UL-listed hardware creates structural and electrical bond - - Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from !any manufacturer certified as"Type 1"or"Type 2" ,. Interlock Ground Zep V2 A DC Wire Clip �L LISTED = Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs _ - � - • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 - • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, zepsolar.com t zepsolar.com 850-1460,850-1467 Listed to UL 1565 This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM r to solar=oo Solar=ooSolarEdge Power Optimizer f�fl Module Add On for North America lhV P300 / P350 / P400 SolarEdge Power Optimizer g PaUD P350 P400 Module Add-On For North America o (for 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) P300 / P350 / P400 d INPUT Rated Input DC Power�'� 300 350 400 W Absolute Maximum Input Voltage(Voc at lowest temperature) 48 W 80 Vdc MPPT Operating Range 8-48 8-60 8-80 Vdc .......... ............ ..... ... .............................. ....... ....... .. ................................. ..... .... Maxmum Short Circuit Current(Ist) 10 Adt 'nunu�' Maximum DC Input Current.. .. ... ... ...... ...... ... ... .......... .12.5............... ........... ..... ..Adt.... 7.�..� ..... ............................ ......................I........................... .....................................I.......... ..... Maximum Effiuency 99.5 % .Weighted EffiaencV ................................... .98.8. ........ ...... ...... ........... ...........g.... .g.ry ........ .............................. ..... .. % Overvolta a Cate o II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Curren[ 15 Adt _ ....axim....Output g.................................................................. ..........,............................ .. _ � ^ Maximum Out ut Voltage 60 Vdc .✓ - +pL OUTPUT DURING STANDBY(POWER OPTIMIZER.DISCONNECTED FROM INVERTER OR-INVERTER OFF).. s.... . 7 Safety Output Voltage per Power Optimizer 1 Vdc ^r STANDARD COMPLIANCE FCC Part15 Class B,IEC610046 2,IEC61000 6 3 - Safety IEC62109-1(class II safety),UL1741 .... .. ....... ............................... ........ ..... .......... ............. ...... ............. RoHS Yes • �"' I P""` .INSTALLATION SPECIFICATIONS . . . Maximum Allowed System Voltage 5000 Vdc ' Dimensions(W xLx H) 141 x.212z405/5 SSx834z1.59 mm/m ..... ............................................... ......... ... ........ ... ... ' y` Weight(mcludmg cables) 950/21 gr/Ib Input Connector MC4/Amphenol/Tyco Out ut Wue T e Connector Double Insulated Am henol .....P..........Typ / P .............................. ...........................0.................. :. ' Output Wire Length 0.95/3.0 1 2/3 9 m/.. Operating Temperature Range 40-+85/40 +185 -C/-F „ _.. - Protection Ratin........................................................................................................................ .......... •, - ...................g................... IP65/NEMA4 Relative Humidity. .................. ...... :................. .......... ......0..100 % . ................................ ........... �Wted STC power of tie motlule.Modde of up to+5%power tdenn<e albwed. PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE INVERTER SINGLE PHASE 208V 480V PV power optimization at the module-level - - - Minimum string Length...... O...... s) 8 10 18 .. ....... ............we.r. ..tim.i........ ............ — Up to 25%more energy Maximum String Length(Power Optimizers) ............25..... .... .25 .... ...... .25. .... ..... _.50.: .,... ... ... Maximum Power per String 5250 6000 12750 W Superiorefficiency(99.5%) ` ........ ........................................ ............................................... ..................................................... — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading - Parallel Strings o.Different Lengths o.Orientations Yes t ..arall..................rent..engt....rOri............................................................................................................................ . —. Flexible system design for maximum space utilization P —Fast installation with a single bolt i I — Nextgenerationmaintenancewith_module-levelmonitoring $ — Module-level voltage shutdown for installer and firefighter safety - /�yy►�`�n/�� - - USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA WWW.SOIaredge.u5 _ �M r ��rsx[s- ' THE Trinamount MODULE TSM-PD05.18 Mono Multi Solutions • DIMENSIONS OF PV MODULE ELECTRICAL DATA @ STC ' • - unit:mm - Peak Power wafts-PMAz wp) 245 [ 250 I 255 I 260 O _ 941 !Power Output Tolerance-PMAz(%J 0-+3 is f, � Maximum Power Voltage-VMP,(V). _ 29.9 [ 30.3 4 30.5 30.6 THE UnnEmount JUNCTION • eox o _I Maximum Power Current-IMpi,(A) 8.20 8.27 8.37 8.50 I. NAMEPure o Open Circuit Voltage-Voc(V) [ 37.8 [ 38.0 [ 38.1 I 38.2 , `' 1 •t4 H'09M j Shari Circuit Current-Isc(A) 8.75 8.79 8.88 9.00 SfA1u. 01E MODULE i'i! 8 Module Efficiency n 9 m( I ,Air ' � 15.3 � 5.6 i 5 yf ( I STC.Irradiance 1000 W/m2,Cell Temperature 25°C Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4.5%a1200 W/m2 according to EN 60904-I. i1 L ELECTRICAL DATA @ NOCT • " Maximum Power-PMAz(wp) 182 186 1 190- 193 60 CELL iii F Maximum Power Voltage-VMP(V). 27.6 28.0 28.1 28.3 1. 6.65 6.74 6.84 A MULTICRYSTALLtNE MODULE � Maximum Power Current-l-P(A) 6.59 ouNo�HCHaLE A [ ( [ [ � WITH TRINAMOUNT FRAME HHOLE - 1 Open Circuit Voltage(V)-Voc(V) 35.1 35.2 35.3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 1 -7.17 7.27 - .. //� NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed I m/s. PD05.18 tea 25� -b////��b0 V V��,/A�/� - a Bock View POWER OUTPUT RANGE MECHANICAL DATA Solar cells I Multicrystalline 156 x 156 mm(6 inches) Fast and simple to install through drop in mounting solution 1 Cell l T. orientation - 60 cells 6 x 10) Module dimension 1650 x 992 x 40 ( 39 05 1 57 inches) III w7/L/A I Y 5�9/ v ��:..-„-_...-�• • o Weight [21.3 kg(47.0 Ibs)mm ` .. .. ., s 64 95 x es MAXIMUM EFFICIENCY - _ - Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass - J - A A BacksheeT White Good aesthetics for residential applications - ,. F Frame - [Black Anodized Aluminium Alloy with Trinamount Groove 1 _ ° i - ox IP 65 or IP 67 rated I /I I-V CURVES OF PV MODULE(245W) JB L Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches2),, 10.00 ! 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9m 8.. . w 2 k Fire Rating Type 2 - -Y�- - _ BOOw/m2 Highly reliable due.to stringent quality control -'°° J • Over 30 in-house tests(UV,TC,HE and many more) v s� m ` As a leading global manufacturer S ;r = In-house testing goes well beyond certification requirements U 4W TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic - 3.00 200w/m2 - Nominal Operating Cell Operational Tem erature -40-+g5°C- products,we believe close z" p g 144°C(+2°C) p p ,I I.- - Temperature(NOCT) 1 Maximum System 1000V DC(IEC) Cooperation with our partners 0.00 I Temperature Coefficient of PMAz -0.41%/°C 11 Voltage 1000V DC UL is critical to success. With local p 1 g ( ) 0.00 10.m 20.m 30.m 40.m f presence around the globe,Trina i5 voltage(V) Temperature Coefficient of Voc t-0.32%/°C Max Series Fuse Rating [.15A able to provide exceptional service --� Temper Coefficientof I .05 /°C ature sc 111 0 % - to each customer in each market f Certified to withstand challenging environmental _ _ . .. _ _ T 1 and supplement our innovative, COndItIOnS reliable products with the backing i . 2400 Pa wind load of Trina as a strong,bankable • 5400 Pa snow load WARRANTY partner. We are committed - } - 10 ye-or Prnduct Workmanship warranty - •- to building strategic,mutually 2s year Linear Power warranty beneficial collaboration with _ _ installers,developers,distributors (Please refer to product warranty for details) and other partners as the backbone of our shared success in - CERTIFICATION �I- drivingSmarTEnergyTogether. LINEAR PERFORMANCE WARRANTY a PACKAGING CONFIGURATION 4a' 10 Year Product Warranty•25 Year Linear Power Warranty cUSTED� c SPA Modules per box:26 pieces w _Trina Solar Limited 4i II Modules per 40'container:728 pieces - www.trinasolarcGom ;t00% Adtliho 5 'J L Aaf V41Ue EU-38 WEEE fro," t COMPLIANL 0 90% °M rrjD°$olar•s 1inecr Wrrafifty - - O CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. taNV4TiA ^°:. _ O 2014 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to 4�o�n�solar p. - Tron-asolar l'!BO% change without notice. Smart Energy Together - Smart Energy Together o Years 5 10 15 20 25 a oMPP e • _ ,�Trina standard 13 Industry standard _ _ THE Tr namount MODULE TSM-PD05.18 Mono Multi Solutions DIMENSIONS OF PV MODULE - ELECTRICAL DATA @STC . • unit:mm Peak Power Watts-PMAx(Wp) { 950 r 255 I 260 , 265 947 t ' O - - Power Output Tolerance-PMAx(%) 0-+3 THE - o Maximum Power Voltage-VMP(V) 30.3 30.5 i 30.6 j, 30.8 7NE'E. mount aximum Power Current-IMPPW IA) 8.27 8.37 8.50 8.61 I NAME-F ,Open Circuit Voltage-Voc(V) 38.0 38.1 l 38.2 i 38.3 0 msrnwxc x°rE Short Circuit Current-Isc(A) 8.79 8.88 9.00 9.10 i MODULE - Module Efficiency tlm ICe I ,Air - I .15.6 i 14-3 f - 16.2 ' STC:Irradiance I000 W/m'.Cell temperature 25"C.Air Mass AMI.S according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. 0 e 0 ELECTRICAL DATA @ NOCT _ Maximum Power-PMAx(Wp) 4 186 I 190 � 193 � 197® CELL ELL Maximum Power Voltage-VMP(V)- 28.0 28.1 28.3 28.4 y. 6.84 Maximum PowerCurrent-IMPP(A) 6.65 6.74 ( 6.93 } MULTIGRYSTALLINE MODULE _ - _ �x 4A°°�-E I 1 A PD05.18 Open Circuit Voltage(V)-Voc(V) 35.2 35.3 35.4 35.5 ,2-°�Axx°LE 1 WITH TRINAMOUNT FRAME Short Circuit Current(A)-isc(A) 7.10_ I 7.17 7.27 ) 7.35 - NOCT:Irradiance at 800 W/m',Ambient Temperature 20-C,Wind Speed 1 m/s. 812 180 250-265W - Back view MECHANICAL DATA POWER OUTPUT RANGE Solar cells Multicrystalline 156.x 156 mm(6 inches) Fast and simple to install through drop in mounting solution Cell orientation 60 cells(6 x 10) AAA Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) r 16•�� Weight 19.6 kg(43.12 Ibs) ® Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY :Backsheet White A f^� A-A Frame �Black Anodized Aluminium Alloy Good aesthetics for residential applications J-Box IP 65 or IP 67 rated ® �� 444 J' _ Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), ~ 0 --�' 1200 mm(47.2 inches) -V CURVES OF PV MODULE(26OW) - a Connector H4 Amphenol POSITIVE POWER TOLERANCE °.°° - - Fire Type I UL 1703 Type 2 for Solar City - Highly reliable due to stringent quality control ow'' • Over 30 in-house tests(UV,TIC,HF,and many more) 70° As a leading global manufacturer ` �/ • In-house testing goes well beyond certification requirements ? 6.. sarw� TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic PID resistant € 6'� n.00 Nominal Operating Cell Operational Temperature,-40-+g5°C products,we believe close as°c(±2°c) e Tempra lure(NOCT) cooperation with our partners a.00 �Maximum system t000v ocpeq ( is Critical to success. With local zoo :Temperature Coefficient of PMAx -0.41%/°C { Voltage 1000V DC(UL) presence around the globe,Trina is - '00 Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service °0° '" `, ° ° _° �° <° so Temperature Coefficient oflsc 0.05%/°C } to each customer in each market Certified to withstand challenging, g� g environmental and supplement our innovative, i conditions "`"'a"" reliable,products with the backing 2400 Pa wind load of Trina as a strong,bankable 5400 Pa Snow load WARRANTY partner. We are committed 10 year Product Workmanship Warranty to building strategic,mUYUQIIy CERTIFICATION '25 year Linear Power Warranty beneficial collaboration with. installers,developers,distributors 4. •-I c 4L BS a- (Please refer to product warranty for details) Q and other partners as the i� Ui ` 6 backbone of our shared success in rwIf driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION 2 EU-28 WEEE 10 Year Product Warranty•25 Year Linear Power Warranty `°M"A"` Modules per box:26 pieces w Trina Solar Limited Modules per 40'container:728 pieces N www.trinasolar.com W009; _ - a AddiHopal value 60 0 90% Sala!'S�ftneq, CAUTION:READ SAFETY AND WSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.O 1QI I�0rr��I �t 02015 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to4Ponasolar 2 80% 4 YY ahasolarchange without notice. Smart Energy Together rears s to Is 20 zs Smart Energy TogethercortPnt`0 Q Trina standard 13 indusiry standard - solar=oo Single Phase Inverters for North America s o I a r e 0 0 Q SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US (� n � SE760OA-US/SE1000OA-US/SE11400A-US SE3000A-US SE3800A-US I SESOOOA-US I SE6000A-US I SE760OA-US SE10000A-US SE114OOA-US ' OUTPUT SolarEdge-Single Phase Invertei S I Q c Nominal AC Power Output 3000 3800 5000 6000 7600 10000�a1240V 11400 VA t- > 5400..208V 1Q(30 . 2 W. ..........._.................. F. i. Max.AC Power Output 3300 4150 6000 8350 12000 VA For North America - � ... �' .....:......... ..................... ................ ................5450.@240y.................. ........ .,...:10950.9240V , AC Output Voltage Min:Nom:Max.lt) �- 183-208-229 Vac SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ CO t.. .. lt....Min.No :. �� AC Output Voltage Min:Nom.Max r I - 211 240 264 Vac ••.•••••• JE/60OA-UJ/JEI000DA-UJ/JEII40OA-UJ � t AC Frequency Min.-Nom.-...... I 59.3 60-.60.5(wrth Hl country setting 57-60-60.5) Hz . - f..� 24 @ 208V 48 @ 208V ' Max.Continuous Current 12.5 16 25 32 47.5 A - ................ ............... ................ .......:.........21,(al,240y....r.............. ...................42 @ 240V, .. - - GFDI Threshold . .1 A I .......................................... .....:.................. ............. ......... ... .... ..._..... ...... ...... ........ - - - .: -�1 •y Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes - ...Yes - - INPUT P�werte� - Maximum DC Power(STC) - '' .-4050 5100 6750 8100 10250 13500 15350 W _ - ' �`, ................... . ............. .......,............... ................................ .. ... ............ ...... t. 2CJ t Transformer less,Ungrounded Yes d- ....................... ................................................................ .....:..............-.. r ` Max.Input Voltage - - 500 Vdc. - leafs i Walla Nom.DC Input Voltage................. ................. .....:.............. . 325 @ 208V/350 @ 240V....... ........ ...Vdc 208V. .... ..... - ' Max.Input Curren l'I - 9.5 13 16.5�208V I 18 23•.••• 33 @ .. 34.5 •• Adc .. _ - ........... ............... .:15:5. .240y............... .I.............. .I..30S,�a1,240V I. .... . . .......Max.. .. ............ .. .. Input Short Circuit Current 45 .Adc ................................... . ......................... ................... ............. - ,: RqXe Pq arily.Protection • Yes ......................... ......... .. ........... - - - Ground;Fault Isolation Detection _ 600ka Sensitivity ....... .Maximum Inverter Efficiency 97.7 ..98.2 98.3 98.3 98 98 .••••98 ._. ••%••• _ ............................................ ................ ... ................. ............. ............ .. .. .. -..... .. - : 97.5 @ 208V ( - _ CEC Weighted Efficiency 97.5 98 97.5 .97 5 975 % . 24 ....8�°... .... .... ........ ... .7.5.( .... ...... .. .. .Nighttime Power Consumption .... ...... - ..... 98<2.5 OV 0V<4.. ...�. - �,_ �� - -�'- �• .ADDITIONAL FEATURES � - - ' •-� - a .Supported Communication Interfaces a RS485,RS232,fthernet,ZigBee(optional) t . ..................................... ................................................................ .. ..... . ........................................................ , Revenue Grade Data,ANSI C12.1 Optional?) . •• Rapid Shutdown-NEC 2014 690.12 functionality enabled when SolarEdge rapid.shutdown kit is installed(-) - j, STANDARD COMPLIANCE f _ ._.. , q. )+,.•�- ( .Safety -.UL3741,UL3699B UL1998,CSA 222 . ........... . .............. ......... ' Grid Connection Standards IEEE1547 - .. ......................................... ........................................................ ...... ... ......... ........ ......... t �, - •• Emissions •. •• ••FCC part15 class B INSTALLATION SPECIFICATIONS Or AC output conduit size/AWG ran e - 3/4 minimum/16-6 AWG 3/4"minimum/8 3 AWG...... ..... � .. . . ... .... ....... ......... ........ ............ ....... .....DCinput conduit size/tf of strings/ 3/4"minimum/1-2 strings/ - 3/4"minimum/1 2 strings/16 6 AWG............... - .. ........... 14.6AVJG ri --•• r`' Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ m/- . �_.-•.-•• + ,. y 305 x 125 x 7.2/.775 x 315 x 184 - -. ............. ...-.......775 x 315 x 260, mm ^ - �' '. - Weight with Safety Switch 51.2/23.2 I •••,••••,•54.7/•247 884/401.•. Ib/kg• ...... .... ................... . . .._..: ... .... .. .. - _ - Natural , convection Cooling _ - Natural Convection and internal - Fans(user replaceable)-, _ - - fan(user - The.best choice for SolarEdge enabled systems . ... ...;.... ........ ............. .........:..... ................ .....:... .. .re•larea A). ......... .... 3 Noise <25 <50 dBA - Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance in.- ..Operating m to si,•................................. .. . ... . ... .. . .. ......... i Min.-Max. Temperature -13 to+140/-25 to+60(-40 to+60 version available ) 'F./ C Superior efficiency(9846) 1 Rang?......... . ...... .......... ........ _ Protection Rating NEMA 3R J - -- s . Small,lightweight and easy to install on provided bracket i i...,,herre.regional pleas....,ctSola,., .support. .....:.........................`..............................................:..........................:. :........... .. For other regional settings please contact SolarEdge Support. (2)A higher current source may be used;the inverter will limit its input current to the values stated. - - j Built-in module-level monitoring Pi Revenue grade inverter P/N:SExxxxA-USOOONNR2(for 760OW inverter:SE7600A-US002NNR2). (4)Rapid shutdown kit P/N:SEI000-11SO-Sl. - Internet Connection through Ethernet.or Wireless 0)d0 version P/N:SE-A-USOOON1,11.14(for 760OW Inverter.SE7600A U5002NNU4). 1 - Fixed and indoor installatione inverter, _erter,DC/AC conversion only � g 1' __ } Pre-assembled Safety Switch for faster installation i - Optional revenue grade data,ANSI C32.1 1; � C/ sunsl>Ec USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL WWw.SOIaredge.US 3