Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0579 PITCHER'S WAY
s7q �� 4 Aers W� f T6WN OF BARNSTABLE BUILDING PERMIT APPLICATION Map 70 Parcel o 5a Application # Health Division Date Issued Conservation Division Application Fee J� Planning Dept. Permit FeeJ 13 •�V Date Definitive Plan Approved by Planning Board Historic - OKH t . — Preservation/ Hyannis Project Street(Address J� ►�G S �a�l Village l Q 0!0 I.S Owner ���'}-n c�a� I�l-�ln-�.\G- Addressit 44 -n n_T oa�o I Telephone 4. �Qb Q. Permit Request -77n5J_4 t1 Sa\&-c- �DAhGls art CDO�- O�- ��c is}�n� �ncJliSz w►�Hn �,,,y �i��TI�Q-�1►c�.Jo(� G 5 � ��'-, 1 b u �� t h � .�h ' �"� ����c��v,n r►�c� Square feet: 1 st floor: existing — proposed _ 2nd floor: existing — proposed '- Total new — Zoning District �1 Flood Plain — Groundwater Overlay Project Valuation 491,obo°—e- Construction Type 9,3 Lot Size Grandfathered: 0`fesk/A-❑-Pie--If yes, attach supporting documentation. Dwelling Type: Single Family Two Family ❑ Multi-Family(# units) Age of Existing Structure vks. Historic House: �� e- On Old King's Highway: ❑Yes allo Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other �V Basement Finished Area (sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing — new Half: existing new Number of Bedrooms: existing _new Total Room Count (not including baths): existing new _ First Floor Room Count Heat Type and Fuel: al ❑ Electric LJ Gther Central Air: J-Yes-4h-U-No- Fireplaces: E�-WA New Existing wo6er'/6oal stove:-aYe No— Detached �m_ti Detached garage: 'ze'�Pool: ❑ ize -Barn: �- �_�co_v „ ,,ze_A* Attached garage: 4Shed: e 4 Other.- � Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes 0 No If yes, site plan review # Current Use :=�S�r�e Jl ,w 4 Proposed Use �p C\&_nQ ie APPLICANT INFORMATION �1 (BUILDER OR HOMEOWNER) Name Grog.�, &,r Telephone Number `7$i. I�, 7Lfi?g Address 912 K Washin4 SfT t* License # C S I b'l (Q[o3 AV r_14 . NJ A Dab io 1 Home Improvement Contractor# Email nmOkz� S5M/,rc.tN. nryv Worker's Compensation # Wl� ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO G C.Nur��5c- SIGNATURE DATE�m�r 01-6/5 4 :✓ FOR OFFICIAL USE ONLY APPLICATION# DATE ISSUED MAP/PARCEL NO. ADDRESS VILLAGE OWNER DATE OF INSPECTION: FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL 2_ GAS: ROUGH FINAL fi FINAL BUILDING , DATE CLOSED OUT fi ASSOCIATION PLAN NO. f DocuSign Envelope ID:B952CB89-5D70-4064-BAFB-ODCBOAF44AAF ► .SOlarCity Power Purchase Agreement ; 1 Here are the key terms of your SolarCity Power Purchase Agreement V Date. 2/14/20l5 I O. . 12 ■ O � O ears_ ' t y System installation cost " ry , Electricity r y r � ty rate per kWh = ���� � Agreement term ►tt -Our Promises to You a. • We insure, maintain,and repaifthe System(including the inverter)at no additional cost to you,as specified in agreement. • We provide 2417 web-enabled monitoring at no additional cost to you,as specified in the agreement. • We warranty your roof against leaks and restore your roof at tle'end of the agreement,as specified in the agreement. , • The rate you pay for electricity,exclusive of taxes,will never increase by more than_2.90%o pegpar. a = • The pricing in this PPA is valid for 30 days after 2/14/2015. ° k . ; • We are confident that we deliver excellent value and customer service:Asa result,.you are free to cancel anytime at Lino charge prior to construction on°yourhome. _ _ �, �u n -c ... e...,..�::_ Estimated First Year Production 10,901;kWh Customers Name & Service Address Exactly as it appears on the utility bill Customer Name and Address --' Customer Name Installation Location Patricia Mehtala 579 Pitchers Way 579 Pitchers Way Barnstable, MA 02601 Barnstable, MA 02601 �F Options for System purchase and transfer: Options at the end of the 20 year term: • If you move,you may transfer this agreement to the purchaser of your • SolarCity will remove the System at no cost to you. Home,as specified in the agreement. " °` • You can upgrade to a new System with the latest solar • At certain times,as specified in the agreement,you may purchase the technology under a new contract. System. • You may purchase the System from SolarCity for its fair • These options apply during the 20 year term of our agreement and not market value as specified in the agreement. beyond that term. . You may renew this agreement for up to ten(10)years in two(2)five(5)year increments. 3055 CLEARVIEW WAY, SAN MATEO, CA 94402 888.SOL.CITY 1888.765.2489 SOLARCITY.COM MA HIC 168572/EL-1136MR Document Generated on 2/14/2015 ❑■ ��■ 566288 LW t ❑ S DocuSign Envelope ID:B952CB89-5D70-4064-BAFB-ODCBOAF44AAF n' 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO entirety and I acknowledge that I have received a complete copy of this MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Power Purchase Agreement. YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Patricia Mehtala EXPLANATION OF THIS RIGHT. Do,c`iS and�by.:� r l 24.ADDITIONAL RIGHTS TO CANCEL. Signature: —f-dVicix'mot T IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: L 2/14/2015 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 2/14/2015. If you Customer's Name: don't sign this PPA and return it to us on or prior to 30 days after 2/14/2015,SolarCity reserves the right to reject this PPA unless Signature: you agree to our then current pricing. Date: = ;Sola�City`. Power rchase Agreemen } SOLARCITY'APPROVED / -' Signature: •� 1 l r{ UNDON RIVE, CEO (PPA) Power Purchase Agreement W'Solareity. Date: 2/14/2015 0w� Solar Power Purchase Agreement version 8.3.1 566288 ❑� am LL bola OWNER AUTHORIZATION Job ID: Location: ; 75 FET,-PtR 5- Wi4Y, ff U1)11-T1 M/4a �° V -`� `: I �r� a �. as Owner of the subject property hereby authorize SolarCity Corp—HIC 168572/ MA Lic 1136 MR to act on my behalf, in all matters relative to work authorized by this building permit application and signed contract. Signature of Owner: Date: II 24 St Martin Drive,Building 2 Unit 1.1 Marlborough,PEA 01752 T(888) SOL,WY s(508)460-0318 SOLARCITY.COM AZ ROC 243771.OA CS1.B B8104,CO CG M41,CT WC C:632778;DC WIC 71101486,0C WS 71101488,HI CT 29770, MA H1C 168572,MU PARK 1285418 NJ 1T41I061606W,NY Wr,24624-141 E,OR COR 180498,PA O77343,TY,n,LR 27006,WA SOLARC-91901 _�e eowwwwwea" 1t,4&aadWje& 0;�, Office of Consumer Affairt and Business Re ulation gl0 Park.PlazaSuite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card. SOLAR CITY CORPORATION Expiration: 3/8/2017 CRAIG ELLS 3055 CLEARVIEW WAY ----- -- SAN MATEO, CA 94402 _ a Update Address and return card.Ntark reason for change. tits as �. q•z?+•a�n�uta Address Renewal i_� Employment t j lost Gard Q1/•0m?O lOto"MY9111, r f, liri.�.Nu*�rtJe✓C Office or Consumer Affairs&Business Reguladun License or registration valid for individul use only f `t' �H tHOME IMPROVEMENT CONTRACTOR before the expiration date. lrfound return to: Office of Consumer Affairs and Business Regulation Repistratlon: 168572 Type: 10 Park•Plaza-Suite 5170 • s Expiration: 3/W017 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION CRAIG ELLS 24 ST MARTIN STREET BLD 2UNI _._ ITi ALBOROUGH MA 01752 -- Undersecretary hot va without signature t .t _ � °h�fBEa06hi.��Qfi'5 i'}4�t�f1[•�grll C9f e"�.ef)llt. S41�ulp 13,0arti at 641ictlog Rettuiallo6i +pit Si inci lrFls . (r)rl+ft tip LI' t t/{tts 1•lirl w•cfiose CS-107663 CRAIG ELLS 206 BAKER STREET 'Keene NH 03431 ,'a :e+ell�lrl rl w, 08/29/2017 r f . c drxe wow'-Iw'?�C>11f111C��t'i��lo C1 f= GG,l1! .�1Gf '� ffice of Consumer Affairs�nd Business Re ulation 4, g — 10 Park Plaza- Suite 5170 Boston, Massachusetts 02116 Home Improvement WContractor Registration Registration: 168572 s .4 , Type: Supplement Card Expiration: 3/8/2017 SOLAR'CITY CORPORATION a NILA MILLER --- 3055 CLEARVIEW WAY ---- SAN MATEO, CA 94402 -- Update Address and return card.Mark reason for change. scA 1 0 20M-05/11 Address 0 Renewal ❑ Employment ❑ Lost Card �c.'l�rarrdtirrt'�iil/�c�r�F'�ic.:.crc�cr�r//^ f)Mce of Consumer Affairs&Business Regulation License or registration Valid for individul use only H OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: r Y1 Office of Consumer Affairs and Business Regulation Registration: 1B8572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/8/2017 Supplement 1:ard Boston,MA 02116 SOLAR CITY CORPORATION NILA MILLER 24 ST MARTIN STREET OLD 2UNI I"hLBOROUGH,MA 01752 :Undersecretary Not valid without signature f . s The Commonwealth of Massachusetts ws Department of IndustrialAccidents I Congress Street,Suite 100 Boston,MA 02114-2017 ww mass gov/dia W workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Apulicant Information Please Print Legibly Name(Business/Organization/individual): SolarCity Corporation Address: 3055 Clearview Way City/State/Zip:_San Mateo,CA 94402 Phone#:. 888-765-2489 Are von an emglover?Check the appropriate box: Type Of project(required): 1.®I am a employer with 9000 employees(full and/or part-time).* 7. []New construction 2.[]l am a sole proprietor or partnership and have no employees working for me in 8. []Remodeling any capacity.[No workers'comp.insurance required] 3.[]t am a homeowner doingall'work myself No workers'corn.insurance 9• ❑Demolition lrs I p ' required.]t 4.rl1 am a'homeowner and will be hiringcontractors to conduct all work on m 1Q.❑Building addition y praperry:I will ensure that all contractors either have workers'compensation insurance or are sole 11.[]Electrical repairs or additions proprietors with no employees. 12.Q Plumbing repairs or additions 5.❑1 am a general contractor and i'have hired the subcontractors listed on the attached sheet. (3:❑ROOf repairs These sub-contractors have employees and have workers'comp.insurance.; 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.Ox Other solar.panels 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. f Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContmctors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. ifthe sub-contractors have employees,they must provide their workers'comp.policy number. 1 am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site Information. Insurance Company Name: Liberty Mutual Insurance Company Policy#or Self-ins.Lic,#: WA766DO66265024 Expiration Date: 9/01/2015 Job Site Address: R, w L'ity!State/Gip: k 0n r Jr I hoOlb a/ Attach a copy of the workers'compensation p licy declaration page(showing the policy nun&cr and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 .and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Offict:of Investigations of the DIA for insurance coverage verification. 1 do hereby ceriijv undoox the nine and Penalties of perjury that the information provided above is true and correct. Signal re* 1l = G_ � ZZ4, Date: Oat, l G aoi 5� Phone#: 781-816-7489 Official use only. Do not write in this area,to be completed by city or town ojjieiaL City or Town'. Permit/License Issuing Authority(circle one): L.Board of Health 2.Building Department 3.Cityaown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: n ,a►. R CERTIFICATE OF LIABILITY INSURANCE- °08/=wDr`""''`� OB129/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed If SUBROGATION IS WAIVED,subject to the tenors and conditions of the policy,certain policies may require an endorsernent A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER - - CONTACT MARSH RISK&INSURANCE SERVICES NAME:NAME;PHONE FAX 345 CALIFORNIA STREET,SUITE 1300 a A/C NO); CALIFORNIA LICENSE NO.0437153 E MAIL SAN FRANCISCO,CA 94104 - ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC A 998301-STND-GAWUE-14-15 INSURER A:Liberty Mutual Fire Insurance Company 165B6 INSURED INSURERS:Liberty lnsuranceCorpoiatian 42404 Ph(650)963-5100 Solaraty Corporation INSURERC:NIA N/A 3055 Cleaniew Way INSURER D: San Mateo,CA 94402 INSURER E: I INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002440269-02 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADOL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCEim POLICY NUMBER imMR) LIMITS - A GENERAL LIABILITY T1312-661-066265-014 09/01/2014 09101 015 EACH OCCURRENCE $ 1'000'000 X COMMERCIAL GENERAL LIABILITY t PREMISES Ea ocamerme $ 1�'� CLAIMS-MADE OCCUR EXP(Any one person) $ 10,000 - - - PERSONAL&ADV INJURY $ 1,000,E GENERAL AGGREGATE $ 2,000,000 H'LAGGREGATELIMITAPPLIESPER: PRODUCTS-COMPIOPAGG $ 2.0WA0 POLICY I X PR4 LOC Deductible $ 25,000 A AUTOMOBILE LIABILITY AS2-661-0662(35-044 09101)2014 09101/2015 COMBINED ac.dantlSINGLE LIMIT 1 ,000,000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED - BODILY INJURY.(Per 3=derd).$ AUTOS AUTOS X X NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS X Phys.Darnap COMP/COLL DED: $ $1,000/$1,000 UMBRELLA LlAB OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ g WORKERS COMPENSATION WA7-66D-065265-024 1 0910t 15 X Vie STATU- MA_ EMPLOYERS'LIABILITYER g YIN WC7-061066265-034 I 09/01/2014 09/01/2015 1,000,000 ANY PROPRIETOR/PARTNER/DECUTIVE - �� EL EACH ACCIDENT $ B (Mandatory Ma dn�ry In EXCLUDED? NIA !'WC DEDUCTIBLE:$350,006 1,000,000 y EL DISEASE-EA EMPLOYE $ DESGIRIa PTION OF OPERATIONS below I EL DISEASE-POLICY LIMB $ 1'000'DDO DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) Evidence of Insurance. A" CERTIFICATE HOLDER CANCELLATION Solarcity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCE I ED BEFORE 3055 CleaMew Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. i AUTHORED REPRESENTATIVE of Marsh Risk&Insurance Services. Charles Marmolejo 01988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD Version#43.1 pp, SolarCit ® OF � YOO JIN !� K i April 8, 2015 A m No.4 Project/Job#026863 RE: CERTIFICATION LETTER Project: Mehtala Residence Y 579 Pitchers Way Di ne stall i Yoo Jin Kim gi Y 9 Hyannis, MA 02601 Date:.2 15.04.08 13:32:48-07'00' To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= MA Res.Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf. - MPl: Roof DL= 9 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL = 21 psf(PV Areas) - MP2: Roof DL=9 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL = 21 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.18757 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load,PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code,8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Yoo Jin Kim, P.E. Professional Engineer Main: 888.765.2489,x5743 email: ykim@solarcity.com 4 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 24$771,CA 031-8 888104,00 EC 8041,CT HIC 0632778,DC HIC.71101486,DC HIS 71101488.HI 0T-29770.MA 1-00 168572,MD MHIC 128948,NJ 13VH06160600.OR COB 100498,PA 077,143,Tk TDLR,27006.WA GCL;.SOLARC'91907.0 2013 SolgrCity.All rights reserved, 04.08.2015 \ '� a Version#43.1 o4;SQ�a��It, PV system Structural Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: " m :$' ehtala Residences,ry AHJ. : {Barnstable_,_4 Job Number: 026863 Building Code: MA Res. Code,Rh Edition Customer_Name: _'Mehtala; Patricia''Based On: IRC 2009// IBC 10_&__;_. Address: 579 Pitchers Way ASCE Code: ASCE 7-05 -City/State: _ Hyan__nis MA :° Risk Category• _ ° Z, 4 eII _¢ Zip Code 02601 Upgrades Req'd? No _.M �.�._ �. _�� ,r., „ #. rv_Yes -Latitude/.Longitude: ,__�_41_656.8,55 ' �` -70_308854„„______Stamp Req d7 - SC Office: Cape Ccd - PV Designer: Cody Anderson �¢ Calculations: Carol Paredes' EOR. oo]in Kim, P.E. z =n Certification Letter 1 Project Information,Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss= 0.18757 < 0.4g and Seismic Design Category(SDQ = B < D 1/2-MILE VICINITY MAP tv" . _' '.11 - I / I . � was 3 ' . LZ • A Se 959- Seeo.'a/-,1,31-,S' �-Commonwealth,of Massa chus6tts;LO EA, USDA Far'm Servioep' gency 579 Pitchers Way, Hyannis, MA 02601 Latitude:41.656855,Longitude: -70.308854,Exposure Category:C `-� STRUCTURE ANALYSIS- LOADING SUMMARY AND MEMBER CHECK- MP1 Member Properties Summary MP1 Horizontal Member Spans Rafter Pro erties Overhang 0.99 ft Actual W 1.50" Roof stem Properties 1 San 1.„ :.. __ .5.75 ft, :z,& N Actual D - -3.50"= 4 Number of Spans(w/o Overhang) 2 San 2 6.13 ft Nominal Yes .Roofing Material Comp;Roof- San 3�- r. „ �vA4 - i' `5.25 in.^2" Re-Roof No San 4 S. 3.06 in.A3 Plywood Sheathing -Yes San 5 ° °gib '"' $' `-` I . 6 .- ' "' 5.36 in.A4 Board Sheathing None Total Span 12.87 ft TL Defit Limit 120 Vaulted Ceiling " No PV 1'Start"" 3.25 ft 'e 'Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 12.25 ft Wood Grade #2 Rafter Slope 25a PV 2 Start Fb 875,psi ; Rafter Spacing 24"O.C. PV 2 End F. 135 psi Top Lat Bracing ,Full _PV 3 Start X" E : o 1400000 psi Bot Lat Bracing At Supports PV 3 End Em;n, 1 510000 psi Member Loading Summa - Roof Pitch 6 12 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 9.0 psf x 1.10 9.9 psf 9.9 psf PV Dead Load n PV-DL 3.0 sf ._ A, x 1.10 A w: x 4,33 psf' t Roof Live Load RLL 20.0 psf x 0.93 18.5 psf / p gx 0.7- (,x 0.7 ° " 21.0 psf}- -v E2t.O:psf Live Snow Load a .:LL SL1�2 � .� � 30.0 sf� Total Load(GoverningLC� TL 1 30.9 pd 34.2 Dsf Notes: 1, ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(Is)p9; Ce=Ct=Is=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+S 1.15 1.00 1 0.93 1 1.5 1.15 Member Anal sis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 58 psi 1.0 ft. 155 psi 0.37 Bending + Stress 753 psi, 10.0 ft.•% ,; My {1736 si 0.43= a Q 4 Bending(-) Stress -1136 psi 6.7 ft. -1621 psi 0.70 (Governs) Total Load Deflection _ 0.17 in. 11 491 9.7 ft. 10.68 in. ` 120` ° '1'0 24' ` '`` [Bending - Stress 1 -1136 psi 1 6.7 ft -1621 psi 1 0.70 Pass FCALCULATIO-N=OF-DESIGN RIND LOADS -MP1 Mounting Plane Information Roofing Material Comp Roof PV S stem T- e SolarCi SleekMount'""__ . Y� _yp - - -- -- tY_ .. . Spanning Vents No Standoff Attachment Hardware x 7 Comn'Mount Tvoe C°`-• _• �'` ,� '�� ,� ^ Roof Slope 250 Rafter�_Spacing - -- - - ff 24"at Framing Type Direction Y-Y Rafters Purlin S acin X-X Purlins_Onl r ,NA Tile Reveal Tile Roofs Only NA Tile Attachment System - T -- le Roofs Only° 'NA 7 ° Standin Seam rap Spacing SM Seam On NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind DesignuMethod 3Partially/Fully Enc�Iosed'P od �.- -- Basic Wind Speed V 110 mph Fig. 6-1 Exposure Category r =aC Section 6 5.6.3 Roof Style _ Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Hei ht 0 - -h (15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factory } 'µ K4 7 7, T 7 7 =1.00 N, Wind Directionality Factor Kd 0.85 Table 6-4-� Im ortance Factor - 7, 75 : s .Table 6-1,.'1.0 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(VA 2)(I) Equation 6-153 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.87 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down _' GC' ;,W " `°r0.45" Fig`6-11B/C/D-14A/B Design Wind Pressure p p= qh(GC ) Equation 6-22 Wind Pressure U -19.5 Psf Wind Pressure Down 10.0 Psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" MaxLAilowable.Cantilever:E Landscape 1 y .a:- _fir .�24" Standoff Configuration. Landscape Staggered Max Standoff Tributary Area v Trip t_ . ,,20 ssfr a _ .- PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff '� �° PT-actual <, -* �_ .� „ :$ -353 Ibs Uplift Capacity of Standoff T-allow 500'lbs Standoff Dernand/Capacityv 4 DCR v 4 ,, .70.6% . . X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 66" MaxAw ele -s- Portrait _ 20" _ „DNA• Standoff Configuration Portrait Staggered Max Standof,Tributa_ry Area 4 '$' „ 4rib _ 22 sf Y PV Assembly bead Load W-PV 3.0 psf Net Wi d plift at Standoff T 4- Tactual r a -392 Ib 5 Uplift Capacity of Standoff T-allow 500 Ibs Stand Demand Ca aci ,�: DCR s � 4 � � � i � �_. , =78.5% u: 4 :m x � A STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP2 Member Properties Summary MP2 Horizontal Member Spans Rafter Pro erties Overhang 0.99 ft Actual W 1.50" Roof System Pro erties 'Spin 1 5.75 It a Actual D: 3.50"., - Number of Spans(w/o Overhang) 2 San 2 6.13 ft Nominal Yes Roofing Material "'CompRoof, San 3 _,„_ .. A._. M .,5.25 in.A2- Re-Roof No San 4 S. 3.06 in.A3 Plywood Sheathing ^ Yes _ San 5 I 5.36 in.^4 _ Board Sheathing None Total Span 12.87 ft TL Defl'n Limit 120 Vaulted Ceiling A, V No° `PV 1 Start"" "1.31ft'- Wood Species _SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 12.25 ft Wood Grade #2 Rafter Sloe Y 250 T PV 2 Start` Fb _, 875 psi Rafter Spacing 24"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full ° °3�+ PV,3 Start ' " "' =` E 1400000psi' Bot Lat Bracing I At Supports PV 3 End Emi„ 510000 psi Member Loading Su Mary Roof Pitch 6 12 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 9.0 psf x 1.10 9.9 psf 9.9 sf PV Dead Load r PWDL 3.0psf' _x 1.10 .3.3 psf., Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load - ' ~° H LL SL1,2 ' u.H 30.0 psf "` z 0.7 (z 0.7: 21.0 psf 21.0 psf Total Load(Governing LC TL 30.9 psf, 34.2 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7(Figure 7-21 2, pf=0.7(Q(Ct)(Is)pg; Ce=Ct=IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL CF Cr D+ S 1.15 1.00 1 0.93 1 1.5 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Shear Stress 58 psi 1.0 ft. 155 psi 0.38 Bending + Stress 747. si 10.0,ft, f,. 1736 si V 0.43 � a" 0, .v <A Bending -)Stress -1150 psi _ 6.7 ft. -1621 psi 0.71 (Governs) _ Total Load Deflection 0.16 in. 498 9.7 ft.-, ; 0.68,in.. .g, 120 :0.24 lBending Stress 1 -1150 psi 1 6.7 ft 1 -1621 psi 0.71 Pass (CALCQ TION OF DESIGN'WIND LOADS�MP2 r Mounting Plane Information Roofing Material Comp Roof PV System Type> _ SoI r.-ity Sl— &UntTM Spanning_Vents No Standoff Attachment Hardware �=-• 3 _4 Comp Mount Tvpe C Roof Slope 250 Rafter Spacing.* " �2 24"O.C. Framing Type Direction Y-Y Rafters Purlin.Spacing sX-) Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment+System -, Ti_le,Roofs Only Standing Searn/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 _Wind_Desi g n Method Part', IRFully_EncI sed Method Basic Wind Speed_ V 110 mph Fig. 6-1 C k n_Sectio_ 65.6.3_ Exposure Gate9orY- �. �. � �. `` �,'. Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height, h `15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Toic,f*-tor _ _ Krt____� 1'.00 pogroph Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Im ortance Factor T 1 • _ Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)N^2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC -0.87 Fig.6-11B/C/D-14A/B ,.,.... e. K ` ;_ . . Ext. Pressure Coefficient(Down)" �' GCS oow, n Fig.6-11B/C/D-14A/B ; 0.45 Desi n Wind Pressure p p= qh(GC ) Equation 6-22 Wind Pressure Up Nut)) -19.5 psf Wind Pressure Down 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max AllowableiCantileve - r 'Landscape 24"' _ NA Standoff Configuration Landscape Staggered Max Standoff Tributary'"Area'' ` Trib .n _ 20 _ _ tiM PV Assembly Dead Load W-PV 3.0 psf Net:Wind_UplifYat Standoff , - T-actual - :_ _ VF_-353 Ibs Uplift Capacity of Standoff T-allow 500 lbs Standoff,Demand'Ca aci - DCR a ,. f -�70.6%_2 X-Direction Y-Direction Max Allowable Standoff Spacing, Portrait 48" 66" MaxAllowable,Cantilever ,-_ Portrait,ffi 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributa Area s - ,_Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at_Standoff �..T a"act-_ual- 392'lbs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci DCR 478;5%" r I� CAPE COD INSULATION NRER DlA9S SEAMLESS SPRAYFOAM SUSPENDED BATES GUTTERS IN9UlAT10N C"L"'" 1-800-696-6611 v o .� Town of Barnstable Regulatory Services Building Division w Ln 200 Main St Hyannis, MA 02601 co-o CO Date: �1�/ Dear Building Inspector Please accept this Affidavit as documentation that Cape Cod Insulation, Inc. performed& completed the insulation and weatherization work at the property listed below. Cape Cod Insulation did this in accordance to the specifications listed on the building permit application. All work has been inspected by a certified Building Performance Institute (BPI) inspector. All work preformed meets or exceeds Federal & State Requirements. Prop erty Owner ) Property Address Village , Insulation Installed: Fiberglass Cellulose R-Value Restricted Unrestricted Ceilings Slopes ( ) ( ) ( ) ( ) ( ) Floors (�) ( ) ( j Gj` ) ( 11) ( ) Walls Oe* v Sincerely hECasJr, President on, Inc. TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map rl Parcel Application #aOtl 3 0 I �a Health Division Date Issued 3 t 3 Conservation Division Application Fee V Planning Dept. Permit Fee Date Definitive Plan Approved by Planning Board Historic - OKH _ Preservation/ Hyannis Project Street Ad ;ress Village Ail- Owner__:kmpkii� Address yU� Telephone Permit Request -I W G 2 Q�� Va ll Square feet: 1 st floor: existing proposed 2nd floor: existing proposed Total new 'Zoning District Flood Plain Groundwater Overlay Project Valuation i Construction Type `�� . Lot Size Grandfathered: ❑Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family Two Family ❑ Multi-Family (# units) Age of Existing Structure Historic House: ❑Yes ❑ No On Old King's Highway: ❑Yes ❑ No Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other Basement Finished Area(sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing new Number of Bedrooms: existing —new Total Room Count (not including bath,,): existing new First Floor Room Count Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other ® o < Central Air: ❑Yes ❑ No Fireplaces: Existing New Existing wood%co•I stove:'1Zl Yeses No a Detached garage: ❑ existing ❑ new size_Pool: ❑ existing ❑ new size _ Barn: ❑ exvi ting ❑-w we—. s?. 70 Attached garage: ❑ existing ❑ new size _Shed: ❑ existing ❑ new size _ Other: -74 L,J Zoning Board of AppealiNo orization ❑ Appeal # Recorded ❑ sa �, Commercial ❑Yes If yes, site plan review # Current Use Proposed Use APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name Vim/ 044%lda Telephone Number Address d &449, U License#011/"00 A/7- �d Home Improvement Contractor# �N Worker's Compensation # �U5 ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJE T WALL BE TAKEN TO SIGNATURE DATE l J J ` i FOR OFFICIAL USE ONLY APPLICATION# DATE ISSUED MAP/PARCEL NO. ADDRESS VILLAGE a. OWNER z DATE OF INSPECTION: FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL " PLUMBING: ROUGH FINAL GAS: ROUGH FINAL - s FINAL BUILDING t DATE CLOSED OUT ASSOCIATION PLAN NO. r , t 1 -. . " Ma<ssachusctts - Delrartmcnt of Public lafetN Boar([of Buil(ling Rc,ulations and Standards Qonstruiction Supervisor License a 6" LicentiL- CS 100988 Pf 9" HENRY CASSIDY 8 SHED ROW, WEStT IEARMOUTH, MA 02673 u� Expiration: 1 1 11 1/201 3 ( uumissiuncr Tr-#: 7620 �_ __ ��, a�yn��y�an"cuea�f�- a�C��' C,r'l�ac�c��•e��,� Office of Consumer Affairs and Business Regulation ��,nrs„tJ 10 Park Plaza - Suite S 170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: '153567 Type: Private Corporation Expiration: 12/15/2t14 Tr# 233831 CAPE COD INSULATION, INC HENRY CASSIDY 18 REARDON CIRCLE _..--------- --- -. __. _-. SO. YARMOUTH, MA 02664 Update Address and return card. Mark reason for change. Address ❑ Renewal (�] Employment Lost Card sG'a i ,:; uiM.uhri i ���r f�oiir.rru iacaecrll� 0 'M111jacl ejeffi t\ Office of Consumer Affairs& Business Regulation License or registration valid for individul use only r ` F OME IMPROVEMENT CONTRACTOR before the expiration date. if found return to: e ration: Office of Consumer Affairs and Business Regulation 153567 Type: g xpiration: 12115/2014 Private Corporation 10 Park Plaza-Suite 5170 Boston,MA 02116 CAPE COD INSULATION,.'INC. HENRY CASSIDY - 18 REARDON CIRCLE SO.YARMOUTH, MA 02664 Aor Undersecretary witho t nat re The Commonwealth of'Massachusetts Print Form Department of Industrial Accidents Office ice of.Investigations f./� I 1 Congress Street, Suite 100 Boston, MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/individual): a Address: City/Site/Zip: V IM Phone #: �0�- '77�j - I Z ► (� Are you an employer? Check t1le appropriate box: Type of project(required): I. I am a employer with 20 4. ❑ I am a general contractor and 1 employees (full and/or part-time).* have hired the sub-contractors 6. ❑ New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp.insurance comp. insurance. required.] 5. ❑ We are a corporation and its ME] Electrical repairs or additions 3.El am a homeowner doing all work officers have exercised their 1 LE] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Root r.e�� yrs insurance required.]'l c. 152, §1(4), and we have no 13.1p 3. Other W��`�r ��i hO employees. [No workers' comp. insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. I lomeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. I I'the sub-contractors have employees,they must provide their workers'comp.policy number. I amt an employer that is providing workers'compensation insurance for my employees. Below is.the policy and job site information. Cka Insurance Company Name: �vl L I N MV Policy #or Self ins. Lic. #: WcA 00 I"? j Expiration Date: Joh Site Address: VI/ City/State/Zip: Attach a copy of the wo kers' compensation p !icy declaration page(showing the policy num er and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a tine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a tine Of up to$250.00 a day against the violator. Be advised that a copy of this statement may'be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify^`ruler the wins d enalties of er'ury that the information provided t bove is true and correct. Si nature: Datef 15 l Phone#: /� I Official use only. Do not write in this area, to be completed by city or town offtciab City or Town: Permit/License# IssuinLOther Authority (circle one): Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector rson: Phone#: GlIelltit: 450 GC I N S Lj L_ A,C_0RD,,, CERTIFICATE OF UABILITY INSURANCE A A MATTER OF INFORMKIIL)N ONLY AND CONFERS NO F IGhTq UPON THL GFRI'IFICATF HOLDFI,.' jil,� CCKH 141c 07/021 20.12 , 6 rllff'1'1'17��[:N I A I'm= CiR PRODLICEP _IUCT BEIVVLEN-11,112 IN'illlill�(S),AU ItIQ I L�14LLI I" 1-C)VV- I I-11ti CER'VIFICAT'IZ C)F INbURANCE DOES NOTCCJNti 11 (IIF A CON I �ATE DDIHES NUT OR NEGATIVELY AM010,EXIFEND OR ALTER THE COVLRACQ AFFORDED UY TI-11:rO IC.I� AND CERTIFICATE I 16L.LQt. � dvl,owr NT Ifliatu I"--- NAL N ColliliccAlk!(IJ,wtl nut cold,:1 to theclldol�icd.IfSU _q8h1E. �( 011 hri. -So. L1VwmII,i El 11 4 J4("ou(v I J.-I 1,c No e,j MA AQCIflFj4._ :)wilh :W11 N0-1`1055 111SUrailco . N.SURtRO LV�11141[011 IjjSUj'jIjCo C Yol mouth kooO _LtqjiRc,i L:Malt IfYmlfli:i, IVIA 026o I Coillp,111V ----------- ...... (.'LIMF.JCA1L'NIJMUER; >,7 i---v I:16 tT Tit.I Fm L I It IN,NiIfRIINCE� ('"E BEEN 1$6(10 TO 11(E MUHFU NAMPIDAGOVL I� lj_-(ftItjj: -I,— t,4 I' 'I� -, 1,�1.o�� NI OF CON�,,'11011101`AI1Y CONTRACTOR OTHER DOCIUMI NI W111-1 TOwjjj(.:It 41r; ii- MAY B1. 1,iPlf,)I.Hi OR MAY Ht`R I'AIN, THEINSURANCI: AITUNOED lJY THIE POI.ICICS D12SCRIDED l WRE-IN IS SUkl,)E(,F 10 ALL. I I W It I(Nl:.j. L.I/til A1,10 C"5NDITION::; OF SUCH POLICIES. Limas st-1cm.), NAV9 fiEcN RLOUCED BY MIO CLAIMS. POLICY_—U_p 11110MM W��. CBP02630611 4101/2012 GI:-I%,-flAL.1,1ABIL11Y 0,000 OCIWOPIAI.6 A0V INJUlitY b ---------- s). 0 0000 APPi-WkI Pf-,H' PNOOLICli-I�CJMPIQP AGG, I 2,q L)0,lj 1)If J,L"Ll,11_�. 12MM6CKVm.A .10112012 04/0-1/19 E, T _ AU I U I.1 10 40011-V INJURY(171- x fll�lj NON-OWNt-1.) All rat p IL f OCCUR L I o 000 0ou - -- --- MAQL t1 LIQU UQU Al I)t.11111 ul l lLS LIAL11LI lv VVCADU5259021 v -L eIN L N/A F,L,IZA(�H AO�IOWO' 11 00 QUO It Net) C.t, Uli'�I_AS.G-1:,k Ckt11i..nYC.0 l'I .4 ...............------ --------------- (JVVI4Ai IONS J LOCAHONS If 111910 Ogqo 11, ",odwn, Comp Infutirl"0011 c,p v I o t 0 1',5 1"' till dCl(1RdUIId1 ilISLI(Od MILIIJI C'.Llnuial 1_00ifity wilum rk)(11.11rod by writtoil I., HCR ........ CANCELLATION 1,41)o GuLl lkl6ulaholl,hic SHOULD ANY OF THE A150V6 OE(� I,.ANHI,LIJ]IJI;I Qjjj; A THE EXPIRATION DATE THEREOF, NCJ'[tCl: WILL HL7 IJFLIVf:ke0 IN ACCORDANCE WITH THE POLICY PROV1310N.3. AUIMORLLUREPIW ENIAIIVE :VWN 0100 -Ul U ACOND CONPORA I 10M All I 191111;r I vvvi vvd. I.,o I um)) 1 GPI` I lit ACORL)Millid alld 1000 X0 roUl-itilrud warks ofACORD m�Y I ' OWNER AUTHORIZATION FORM (Owner's Name) owner of the property located at 3 71 �•f��i�•-s Gas (Property Address) (Property Address) hereby authorize (Subco ractor) an authorized subcontractor for RISE:Engineering,to act on my behalf to obtain a building. permit and to perform work on my property, Awnerignature 10 Date Assessor's map and lot number ......................................:... 7 07 Sewage' Permit number .......................................................... �"ET°� TOWN OF BARNSTABLE �BAWST"LIE, i F M6 9 BUILDING INSPECTOR 3 APPLICATION FOR PERMIT TO .............�....^ ....:........................�.-..%........................................................................... �,• TYPE OF CONSTRUCTION ............... / .....a;?. r�'' Z ! ...........`...................................... i ................19./ ? TO THE INSPECTOR OF BUILDINGS: The undersigned hereby applies for a permit according to the following information: Location J.)�... 1 - I�/ r'/elel- ........Wfl.-,&A,/ r.......................................................................... J.: .. ProposedUse ...... ......... ........................................................ ........................................../................................................... Zoning District Fire District ! '............/............ ....w.................' .. ................................................... Name of Owner .......� :n.�:./. ............LPi/................Address ................. -' 'i //,f................................. 5 Nameof Builder ....................................................................Address .....................r............................................................ 1 l � Nam. of Architect ..................................................................Address .................................................................................... Number of Rooms Foundatio .......................... !!. '..:................................... ................................................................. Exierior ...�.. ...Roofing F��. .......................................... .............................................................. l Floors 1./,14 � ram.....................................Interior .............-.......z�c�/? c� ... ........................ ...............:..... .....`................................. Heating . /�o /"�/.......................Plumbing.............. ,�, ........... ................................................................................. Fireplace ,r)/'1 nrd o p Approximate Cost ... .......................................................... Definitive Plan Approved by Planning Board ________________________________19________. Area �o <. . — ll ........... ................. Diagram of Lot and Building with Dimensions Fee ��J .............. .............................. SUBJECT TO APPROVAL OF BOARD OF HEALTH .f �r i •y I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regarding the above, construction. 4 '�� Ae Name . `/r ............... .!...?`:.... ......... � �= ���� �=���~��� . . | --�-'--- --"-'�- 19610 one m ` No ................. Permit f8r .................... Jr , . ^ | single family dwelling ^ . --_----------'-''..------'-'l�^''' / oi-� ` Locotion ....................................................... uymuusim . --'-^-----^~'--------------'~ Capewide Development ^ Owner ----'................---.................---. frame � Type of Construction .......................................... ....................................................- Plot "^' Septe4ber 16 77 � Permit Granted, . ----. 19 ` � . Dote of Inspection Date Complet'e;d/.........................................19 PERMIT REFUSED 19 ° . � . - ~~� "^ -- ^ ^ =' ---'---'-' ----^ ' ' - ---.-�-'�--.~�- lg ' ' ' - ----..--.--.----.-----...-.~--... x � ----.---------------.-.,.."..., . � | � - | / Assessor's map and lot number 4 `m 4 V� SEPTIC SYSTEM MUST BE of w Sewageu Permit number .... INSTALLED IN COMPLIANCE S HI—I A€�TLCLE II STATE C �.11 T �q n F:?NE T ..� �� ��' LVNDE TOWN 4: a�. 01 R TOWN" OF BARNMI,AB� ry i E9'fiHSTAI14E i y n, °" `tv•� BU1i.DING INSPECTOR �p 639. `� MIX- 0 Py APPLICATIOrI FOR PERMIT TO ,�rG�� `...... .. . ................................... TYPE OF CONSTRUCTION : ..... ... !. . ..... .........................................:. 1 ........... ................19.7 TO THE INSPECTOR OF BUILDINGS: The undersigned hereby.applies for o permit according to the following information: Location ..�7.0... .. .....�-�� .�.�.,//�,.�..�.4,9... ............................ .....:..... ................... Proposed Use ..... - ellf .............................................................. ...... . ......... ................ Zoning District a:....� ..........Fire District ../ � 6o. ......... ....................................... ....... .... .................................. 6 Name of Owner ....... jf- .�11 �......% ............Address „/�✓ 1,� .. Nameof Builder ....................................................................Address ...............................1................................................... l Nameof Architect ..................................................................Address ............................`...................................................... Numberof Rooms ...................6...........................................Foundation ...........,...... 41.��(/�..c................................... >� Roofing ............ � �' Exterior ........................ ......................................... Floors ................. �..4.!.........................:...........Interior .......... ...�l�� e� Heating .......... ......................Plumbin ........................`..........:............................:.................. Fireplace ...................ON. .............................................Approximate Cost ...... J..s.Qv ................................... Definitive Plan Approved by Planning Board ________________________________19________ . Area ...../Q4 �2........ . . Diagram of Lot and Building with, Dimensions Fee .. ......... ................................... SUBJECT TO APPROVAL OF BOARD OF HEALTH I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regardin th . ep�ov construction Na .. ................. . ` ' ' . . - ` � � ^ - ' ^ . . ^ � , � . - � - - - ' � ^ - ` - ' ' . . , . . � Capewide Development 19610 one story single family dwelling Pitchers Way HyairiniS Capewide Development frame Date Completed PERMIT"REFUSED ' � ^ - � I . ' . --...--...'--.-.—...~..--.-- � Approved ................................................ 19 ' � ^ - � . ---------'--'-----^^^-^^ ' -----..---------.......,. . . � .-0 7- / Z f' Cry rC8 VA% a IoUoCAL 'Sl:p FK V.) A%0 4 1 CO u C'. � a L O 7 of Mqu � , °11 WILLIAM �y C. ^It x ,f NYE No. 19334 A- �SY E 0 SUR`.i y1 a -SIZTIFIaD IPLC)-' tOCATIo" t+-!N M JAI S, M/4,5 S ��-.GAL l= i I►.l=�p F i b•AT� _ � �� ,�`� CriZTIFV TNAT THE 1-C?�N�QI�VU St-1ow1.1 --A� RSF'ERc�.1Ca Wr--er=a" CO APLYS W ITN TWF-- 5ivr=.uwC-- Lo -T I AWD seT$ACIC vsQLmzEAAF-wTS OF T'4e TO W IJ OV= 6(ae.,1J . : `� g.a x-rc� � ►�yE 1�►.IC. / REGiS•t'�.IZ�D 4..AI.t� 5t�evc�(��'s THIS D�. AI-1 (5 LJOT SASE 0"4 pN OSTE2VIL.LE o /4C�4SS� 11Js("QlJ�VIEtJT SOZvm`e 4 TNt= 4NowLr-> APPL1 CA.ti1T DE pty Ca kJ, T SS USED Tb DETEeMIWC-- LOT LINES t~LC>w 11b v t-),4c---- k C>«C) GAL.. , SPcx L PsT - usE I eao C-,&�- Uzw.4LL A2E-A = 150 '11,.P7. 1�,� SF• � 2.� � �7� G.P.L>. T3,CrT`r0XA 4kV_M-A t 1.4> SF. To-r'AL. -T7ESI6I.I = 42G G,•Vra• TOT&L F:Lt>�A_/ = 330 6.w. PT:_:fZCDL&T10L1 C2AT-I` CiQ SAAw orz LEsS. r i ( 1 9 i 1 o'P IOG�.b i �.csA/n � ��P� I n�o iuv 43.3 •�;� pSUIL 4 -Z 'Pn� q3. GoL. f 1 ttv. I Ta ti1�:. 55 loco 9zld• i1Nv tlJv. A I LeA-_H A I 0 FIT v wlru Y G was�Ieza F;.2 T 1 F:1 C-.tD P l_b'T- -1 � ----- -- — ----- L b C..A Z'I o�.., �.�y d. ►,� ►� ! 5 1�d . 1 ,l --� ,p adoce.Lar SaCA1_E;= 1�ATI �'C1 �1 4 k14rc CGzIZTIP-- TI-�A.T YOU- @5tAcrkJk3 ,UQ TZs=1 V_ak~IC& v< Z :}? C�I5t�1 Gca°�tr'L�(5 �'./ l'S'1-? i ► 1� 51 D-= U'-lET L.rC�'T" rJ tZ C G t m_;i i::-1-3 D U Z ^_i= lt.l;I�':Jl.'�i 1.1;' '',l.)S��/l:�' 'il1(:-. t>Ft�'%/r':C ; 'illt.•tJt {r,P Pk_I C&1�.1T C��C W I f,7C Dt CV I t..t,•,r t'=,I • ��<.�� 1F� ter• 1 � t_./w�sb.Jt; 1_�.>`C' l._I 1-1�.:� -• - ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A a AC ALTERNATING CURRENT UL—LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. Kc CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE .WITH ART. 110.3. - (E) EXISTING 4, WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. CURRENT 6.. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. . NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL I STC STANDARD TESTING CONDITIONS TYP- TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Vac VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT PV1 COVER SHEET 3R NEMA 3R, -RAINTIGHT PV2 PROPERTY PLAN, PV3 SITE PLAN PV4 STRUCTURAL VIEWS PV5 UPLIFT CALCULATIONS. LICENSE GENERAL NOTES PV6 THREE LINE DIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: AHJ: Barnstable • REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: NSTAR Electric (Cambridge Electric Light) PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN FER NUMBER: J B-0 2 6 8 6 3 00 ,�. CONTAINED SHALL NOT BE USED FOR THE MEHTALA, PATRICIA MEHTALA RESIDENCE Cody Anderson a BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SYSTEM: ,SolarCit NOR SHALL IT BE DISCLOSED IN WHOLE OR INComp Mount Type C 579 PITCHERS WAY y PART TO OTHERS OUTSIDE THE RECIPIENTS c 1 0.9 2 K W.P V ARRAY ''1 ORGANIZATION, EXCEPT IN CONNECTION WITH HYANNLS, MA 02601" TMK OWNER: ^ THE SALE AND USE OF THE RESPECTIVE Hanwha Q-Cells #Q.PRO G4/SC 260 * z4 St. Martin Drive,Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ARM: PAGE NAME: SHEET: REV: DATE T: (650)Marlborough, F:A(61752 638-1029 PERMISSION OF SOLARCITY INC. REDGE SE1000OA—US000SNR2 5082747902 COVER .SHEET PV 1 4 8 2015 www.solarcity.com / (888)—SQL—CITY(765-2489) wwwsolarcit com >t a 4 f PROPERTY PLAN N Scale:l = 20'-0' W E 0 20' 40' S i PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0 2 6 8 6 3 00 ■ CONTAINED SHALL NOT BE USED FOR THE MEHTALA, PATRICIA MEHTALA RESIDENCE Cody Anderson ,,`�Olar�'+� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �� 1. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 579 PITCHERS WAY 10.92 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: H YAN N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) Hanwha Q—Cells #Q.PRO G4/SC 260 PAGE NAME SHEET: REV: DATE Mmlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. soLAREDGE SE�000OA—uS000SNR2 5082747902 PROPERTY PLAN PV 2 4/8/2015 (888)—SOL-CITY(765-2489) www.solarcity.com a PITCH: 25 ".ARRAY PITCH:25 M131 AZIMUTH:93 ARRAY AZIMUTH:93 MATERIAL: Comp Shingle STORY: 1 Story tHOF PITCH: 25 ARRAY PITCH:25 MP2 AZIMUTH:273 ARRAY AZIMUTH: 273 MATERIAL: Comp Shingle STORY: 1 Story AC YOO'JIN � No.4 7 AL -Digital signed by Yoo Jin Kim Date:2015.04.08 13:30:06 -07'00' je B ; LEGEND ,d (E) UTILITY METER & WARNING LABEL ® A 74 Front Of House INVERTER W/ INTEGRATED DC DISCO ccn & WARNING LABELS 12 DC © DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS o f D �I DISTRIBUTION 'PANEL &-LABELS Lc LOAD CENTER & WARNING LABELS M DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE m_ Q HEAT PRODUCING VENTS ARERED INTERIOR EQUIPMENT IS DASHED - SITE PLAN N Scale: _ 1/8 1 W E 0 11 8 16 Rd p"dwsm s CONFIDENTIAL— THE INFORMATION HEREIN TDB NUMBER: J B-0 2 6 8 6 3 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: \\` . ,r. CONTAINED SHALL NOT BE USED FOR THE MEHTALA, -PATRICIA MEHTALA RESIDENCE Cody Anderson ; BENEFIT OF ANYONE EXCEPT SOLARCITY INC. . . MOUNTING SYSIEM: � .. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C . 579 PITCHERS WAY 10.92 KW PV ARRAY .,solarCity , PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES - H YA N N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St Martin Drive,Building 2,Unit 11 " THE SALE AND USE OF THE RESPECTIVE (42) Hanwha Q—Cells #Q.PRO G4/SC 260 x 1 SHEET: REV: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME 'T: (650)638-1028 F: (650)638-1029 PERMI SSION OF SOLARCITY INC. ISOLAREDGE sE1000oA—us000sNR2- 5082747902 � SITE PLAN PV 3 4/s/2o15 c666>-SOL=GITY(765-2489) www.ealarattycam _ I S1 S1 ' „ 1, 5,-9" ,-2" 01 1 5'-9" ,_Z» 01 (E) LBW (E) LBW SIDE VIEW OF MP2 NTs SIDE VIEW OF MP1 NTS B A MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 273 PITCH 25 STORIES: 1 TOP CHORD 2X4 @ 24" OC ROOF AZI 93 PITCH 25 STORIES: 1 ARRAY AZI 273 PITCH 25 ARRAY AZI 93 PITCH 25 BOT CHORD 2X4 @24" OC Comp Shingle BOT CHORD 2X4 @24" OC , Comp Shingle PV MODULE 5/16" BOLT WITH LOCK FINSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ~ ZEP ARRAY SKIRT (6) HOLE, OF 41 (4) (2) SEAL PILOT HOLE WITH py'� Y00 AN POLYURETHANE SEALANT. i ZEP COMP MOUNT C K ZEP FLASHING, C (3) (3) INSERT FLASHING. No.4 � (E) COMP. SHINGLEAL (4) PLACE MOUNT. (E) ROOF DECKING (2) V G INSTALL LAG BOLT WITH Digitall oo Jin Kim 5/16" DIA STAINLESS (5) SEALING WASHER. Date: 15.04.0813:30:15 STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES NSTALL LEVELING FOOT WITH 07'00' WITH SEALING WASHER C(6)F BOLT & WASHERS. (2-1/2 EMBED, MIN) (E) RAFTER STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN aoe NUMBER: J g-0 2 6 8 6 3 00 PREMISE OWNER: DESCRIPTION: DESIGN: ■ CONTAINED SHALL NOT BE USED FOR THE MEHTALA, PATRICIA MEHTALA RESIDENCE Cody Anderson �_ •. t , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 0 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 579 PITCHERS WAY 10.92 KW PV ARRAY ��� Ohr I {ry PART TO OTHERS OUTSIDE THE RECIPIENTS ISIDLAREDGE ULES H YA N N I S M A 026 01 ORGANIZATION, EXCEPT IN CONNECTION NTH , 24 SL Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE 42) Hanwha Q—Cells #Q.PRO G4/SC 260 PAGE NAME SHEET: REV: DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN RTER: T: (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. SE10000A—USOOOSNR2 5082747902 STRUCTURAL VIEWS PV 4 4/8/2015 (686)—SOL-CITY(765-2489) www.solarcityxorn UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. J B—O Q O O CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: L� U P CONTAINED SHALL NOT BE USED FOR THE MEHTALA, PATRICIA MEHTALA RESIDENCE Cody Anderson SolarCity. BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 579 PITCHERS WAY 10.92 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES H YA N N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) Hanwha 0—Cells #Q.PRO G4/$C 260 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: T: (650)638-1028 F.- (650)638-1029 SOLAREDGE SE1000OA'—US000SNR2 5082747902 UPLIFT CALCULATIONS PV 5 4�8�2015 (888)—SOL-CITY(765-2489) www.solarcity.com 1, GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ##SE10000A-USOOOSNR LABEL: A -(42)Hanwha Q-Cells #Q.PRO G4/SC 260 GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:2303505 Tie-In: Supply Side Connection Inverter; 100DOW, 240V, 97.574 wUnifed Disco andZB,RGM,AFCI PV Module; 260W, 236.5W PTC, 40mm, Blk Frame, MC4, ZEP, 600V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 37.77 Vpmax: 30.46 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 100A MAIN SERVICE PANEL ` E; SolarCity 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER-HAMMER Inverter 1 Disconnect 4 A 1 10OA/2P 6 5 SOLAREDGE DC+ - B 60A SE1000OA-USOOOSNR2 DC- - MP1: 1x17 EGC A \ _ L1 2�V -_________ _2 s L2 N DC- i 34cl MP2: 1x13 (E) LOADS CND ------------------------------------- -EGG --- DC+ C MP2: 1x12 GEC N DG EGC--- EGC --------- ------------ --+---- --- --- ---------- -- I N I - - (1)Conduit Kit; 3/4" EMT - - I o EGC/GECLi L'i - - - - GEC TO 120/240V SINGLE PHASE I I U11UTY SERVICE I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN VOC* MAX VOC AT MIN TEMP OI (2)Ground Rod; 5/8' x 8', Copper B (I CUTLER-HAMMER #DG222NRB /f►� A (1)SolarCitYg 4 STRING JUNCTION BOX D� -(2)ILSCO IPC 4/0-#6 Disconnect; 60A, 24OVoc, Fusible, NEMA 3R /y 2x2 STRMGS, UNFUSED, GROUNDED Insulation Piercing Connector; Main 4/0-4, Tap 6-14 - ( )(1)CUTLER-�LAMMER DG10ONB \, 42 SOLAREDGE jf 300-2NA4AZS Ground/Neutral d; 60-100A General Duty(DG) P.v PowerBox hmizer, 300W,H4, DC to DC, ZEP SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE -(1)CUTLER-HAMMER #DS16FK V P AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Class R Fuse Kit (1)AWG#6, Solid Bare Copper -(2)FFusA Z60 A 2 OV,# TRR60RK5 PV BACKFEED OCP nd -(1)Ground Rod; 5/8" z 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE (1 AWG #6, THWN-2, Black 1 AWG #6, THWN-2, Black 1)AWG #8, THWN-2, Block Voc* =500 VDC Isc =30 ADC (2)AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG #6, THWN-2, Red (. '7 1 (1)AWG #6, THWN-2, Red O (1)AWG #8, THNM-2, Red Vmp =350 VDC Imp=18.33 ADC O cP (1)AWG #6, Solid Bare Copper EGC` Vmp =350 VDC Imp=12 46 ADC (I AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=42 AAC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=42 AAC (1)AN #10, THWN-2,.Green. . EGC. . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #6,.Solid Bare,Copper. GEC. _ _ -0)Conduit.Kit;.3/4°.EMT. . . . . . . . . . . . . . . . .-(1)AWG #8,,TFLWN-2,.Green . , EGC/GEC.-(1)Conduit.Kit;_3/4".EMT. . . . ,. . . . . (1)AWG #10. THWN-2, Black Voc* 500 VDC Isc =15 ADC (2)AWG #10. PV WIRE, Black Voc* 500 VDC Isc=15 ADC O (1)AWG #10, THWN-2, Red Vmp =350 VDC Imp=12.46 ADC O (1)AWG #6, Solid Bare Copper EGC Vmp =350 VDC Imp=9.53 ADC . __.. . . . (1)AN #10, THWN-2,.Green_ . EGC. . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J B-0 2 6 8 6 3 00 ■ CONTAINED SHALL NOT BE USED FOR THE MEHTALA, PATRICIA MEHTALA RESIDENCE Cody Anderson BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��,� olar '�y NOR MALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 579 PITCHERS WAY 10.92 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- H YA N N I S M A 026 01 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (42) Hanwho Q-Cells #Q.PRO G4/SC 260 PAGE NAME SHEET: REV: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T.- (650)638-1028 R (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE1000OA-USOOOSNR2 5082747902 THREE LINE DIAGRAM PV 6 4/8/2015 (�)-SOL-CITY(765-2489) www.solarcity.com Label Location: Label Location: Label Location: (C)(CB) IAIV� (AC)(POI) (DC) (INV) Per Code: - Per Code: Per Coder NEC 690.31.G.3 •0 0 0 lon NEC 690.17.E - NEC690.35(F) •'+ : - ` - o 0 0 • •- TO BE USED WHEN Label Location: 0 (DC)(INV) o BMW—•-o. o • -o • • • s INVERTER IS, O Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: . Label Location: - o' o o � (POI) _o (DC) (INV) ,_ ° - ° e Per Code: Per Code: •-• •o o o NEC 690.17.4 NEC 690.54 NEC 690.53 I, I 6 021111 ( • o- it 4 Mir - o _ o- Label Location: ' n (DC)(INV) Per Code: o •-n . NEC 690.5(C) �' 'o • ° • ` o- L -o • • Label Location: o • o- (POI) -o • • • - • • •° - o - Per Code: o • o - - o 0 0 NEC 690.64.B.4 ' t Label Location: o W (DC)(CB) - ° ,-• Per Code: MM Label Location: •e _e e - NEC 690.17(4) OLIV (D) (POI) TfAZIPIA"Mo :o a o o l o Per Code: °°• ° • NEC 690.64.B.4 IG -o 0 0 M00- Label Location: to _lJtlV� (POI) t Per Code: Label Location: 0 e NEC 690.64.B.7 - O O p (AC) (POI) •io o - o _ (AC): AC Disconnect D O Per Code: o - Conduit NEC 690.14.C.2 • (CB) . - Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect • GJ (AC)(POI).: (LC): Load Center o- Per Code: x. (M): Utility Meter _ r/ NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR -�.ry�I 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED +- ■ San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set ������� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �0 �O f ' (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. r. o I'SolarCity ®pSolar Next-Level PV Mounting Technology ',"-SolarCity ®pSolar Next-Level PV Mounting Technology 4 Zep System Components for composition shingle roofs Up-roof - J- , Interlock - Ground Zep (Vey sine strewn) Leveling Foot . Zep Compatible PV Module .Zep Oroore . y Roof Attachment - Array Skirt r s e�F Description H r / W - PV mounting solution for composition shingle roofs �pCOMPPt�e - Works with all Zep Compatible Modules - t� f,„ - Apo" • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond V� Comp Mount Interlock Leveling Foot LISTED . Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703- Specifications Mounting Block to UL 2703 Designed for pitched roofs - Installs in portrait and landscape orientations Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards Zep System,grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 ,' • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for - This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspals.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf - Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 g o o a r' ' oXo :- L1 solar=qq SolarEdge Power Optimizer `S Module Add-On for North America ' P300 / P350 / P400 SolarEdge Power Optimizer . 0 - P300 P3SO P400 ica � (for 60-cell � if ePV (for o6d.ucl eRPvModule Add-On For North Amer modules) modules) m es) a (INPUT - .: j .. P300 / P350 / P400 ^ Rated Input oC PoweH')....... ...............,... 300 359.... avg..... "..:. 1L71 Absolute.Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc - .. MPPT Operating Range.... ... ..................$..48 8 60 ' ....... 8 80 Vdc ... ...... ..... ............ .............. Ajc. " Maximum Short Grcwt Curren[(Isc) .., 10 Maximum DC Input Current 1 2 5 Adc .. ................................... ............ 11 Maximum Efficiency 99 5 % .................... ... ... ............... .. .. Weighted Efficency. ........................98.8., ..... ... ..I...... Overvoltage Category II 1 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTEDTO OPERATING INVERTER). ;1 Maximum Output Current ............ ............ 15. .............. ...... ......... Adc.... Maximum Output Voltage 60 Vdc _,. - f OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) '" I� Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE .- •fir EMC - FCC Part15 Class B,IEC63000 6-2,IEC61000 6 3 -r ... ..........I.. .. ........ ......... ... .......... ........ .......... ....... - .. �! r Safety IEC62109 1(class II safety)UL1741 .. RoHS Yes .> a I INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ... ..................... .... ..... .. - • Dimensions(W x L x H) 141x212x405/5.55x834x159 min/m ............. r' Weight(including cablesl:.... .... - ............ ....... ...... ..... ..................... ............................... .. Input Connector - MC4/Amphenol/Tyco Output Wire Type/Connector' • Double lnsu late d;Amphenol Output Wire Length.. .... ................. ...... .......I......................... .. ...�./ft... - _ _ Operating Temperature Range ,,... .., -40 +5 40 +185... ........ .... 'C/'F.... ' Protection Rafing ....................IP6 /,NEMA4 r Relative Humidity .. . .........................0 100.. ......... ........ ........... • naea sreo�,ortn:n,oem�moa�m oi�nmsx�re.,o c.a�rea io�a )PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE j SINGLE PHASE _ . . I INVERTER ..,. -_ - ,w - � � 208V 490V PV power optimization at the module-level MIOIm..... gLengtn(Poweroptim...... .................... So 18 . ' izes Maximum String.Length(Power Optimizers) 25 25 50 — Up to 25%more energy ....... ....... ............. .. ...... ... .. ..... ....... ...... .... ....... ....... ......... .... ............ .. ... .. .. .. ..... Maximum Power per String 5250 6000 12750 W Superior efficiency(99.5%) ... ............ ........I... ............ ........ ... .. ..... ... ..... .... .. , Parallel St rings of Different Lengths or Orientations .......................................Yes:. __....._ .._........._ •. — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading - "" """'" """ """.. """ "' ' "' '.. '.. - - Flexible system design for maximum space utilization - - - - - -'Fast installation with a single bolt' - Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE.- JAPAN - CHINA - ISRAEL - AUSTRALIA WWW.SOIaredge.u5 E c, Single le Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US "soIare SE7600A US/SE10000A US/SE11400A US •'" SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE760OA-US SE10000A-US SE31400A-US xRM f OUTPUT SolarEdge Single Phase Inverters UU ... . . - .rOutp...... ...... 3000... ... 800... ...6000... 7600... 9980C^�208V .�n. Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA r � 7 13 _ p 10000 @240V k t 1 •'• Max. Power Output 5400 @ 208V 10800 @ 208V - . .. F 0 North rl America 1 m Q r I n {� r� (� M AC P 3300 4150 6000 8350 12000 VA IV 1 ` A m e lr {'"'u 1 - - - - • ................ .. 50 @2... ..... 10950 @240V AC Output Voltage Min.Nom:Max.* 54 ✓ ✓ �"� • 183 208 229 Vac SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ r No .......... ................ ................................ ................ .No�. AC Output Voltage Minm:Max.* ✓ ✓ ✓ ✓ ✓ ✓ ✓ 211 240 264 Vac SE7 - - SE1000OA-US SE1140OA-US ............. ............................. ..... .......... ................................................ .......... ....................... ............................. 600A-US/ / iO 246@ zoav{w ............ ... ...... 60:aa .........-.... AC Frequency Min:Nom:Max.* 59.3 (with HI country setting 57 60 Hz �• Max.Continuous:Output Current 1611 2.5 I-- 16 _ - 21 25 32 47.5 A ....@ 240V................... ....................42...240V...................... 1 A ,. ...... .. ...... .......... ... ... .............. .. ..... _ - Utility Monitoring,Islanding <..- "`•j" Protection, is -Country Yes . . Thresholds , F� rnffJ �� INPUT { Recommended Max.DC Power**. � - 3750 4750 6250 7500 9500 12400 14250. W . . . aR ;(STCJ............................... ............ ............. ........ ............................. eats Wa ,' Transformer-less,Ungrounded Yes a72an ................... .............:....:.....:..:....,............,...:...............:..............................,................. Max.lnput Voltage ........ ..... ...... .......... - .. .... .. ....500... .. ..... ................................... ..... Vdc .. . . ,, ! ;, Nom.DC Input Voltage................. ... ..325 @,208V/-350•@ 240V.......................,... ................ ....Vdc... a . . .. . ........ r - ��-••••�� •� •� ••16:5�•••208V 33 208V ' • � Max Input Current* * 9.5 ••13 @ 18 23 @ 34.5 ..Adc a. R 15.5 @ 240V ( I 30.5 @.240V ............. ......... .. .... ....................... ..................... ..... ................. ..... }„ "' '�'•'' Max.Input Short Circuit Cur rent 30 - 45- -••Adc •• - -, ........................................... ............................. .................................... .................................... .... Reverse Polarity Protection Yes - - - " """"�'"""-" '' '`• Ground-Fault Isolation Detection 600kn Sensitivity - - g • Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 -98 98 - F,. ............................... .............. ........... ............ .......... ......... 97.5 @ 208V• -97.@ 208V ..............I................ I................ ................I....:..@.............: . = •, � CEC Weighted Efficiency 97.5 98 97.5 97.5 97 5 % _ � - . k, 98@240V 975 240V ••- •,.. ........... { • Nighttime Power Consumption <2.5 <4 W- I ADDITIONAL FEATURES ) .-` -• - - --�- k Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) - - ( ., „"� � • P Revenue Grade Data,ANSI C12.1 Optional r STANDARD COMPLIANCE. i " t _ "'"' ` -"'1' t x " •• - SafetyUL1741f UL16998,•UL1998,CSA 22.2 .................. .:..:....... ........................... .................... ........... ......... .....:.................. (- 1 Grid Connection Standards - - - IEEE1547 . . .. �, ......................................... .............................................. .... ...... ....... ........... .... . .. .................. ....... -• -✓ _ Emissions FCC part15 class B - { r INSTALLATION SPECIFICATIONS l size/AWGrange ...................3/4"minimum/24 .....-6AWG••• ••••••••.•- •-..-.• ..........................minimum/83AWG............. ••••••••• f �•= -- .......... DC input conduit size/N of strings/ 3 4"minimum 1-2 strings 24-6 AWG 3 4"minimum 1-2.strin s 14 6 AWG * (.. „-."°' , ' • AWGrange / / g / / / g / . . _.._- r > • :; ..Dimensions with AC/DC Safety...... ......30.5 x 12.5 x 7./..... .....30.S x 12.S x 7.5/..... ............................................................... 0.5x12.5x10.5/775x315x260 - - 775 x 315 x 172 775 x 315 x 191 3 mm" ..�..._. ,..�_._..�..._.�,. -. ,. .. ...... ...... ....... ........ .......... .. ................. .._, . . ... ... .. .. ....... ..... .. .. ..... ..... ..... Weight with AC/DC Safety Switch 51.2/23.2 54.7/24.7 88.4/40.1 Ib/kg - .................................._........ .................................................................. ................................................................. . . - Cooling Natural Convection Fans(userreplaceable) - The best choice for SolarEd a enabled systems Noise .............. .<zs.. ................ ........................... ..................... .dBA No ise g Y ..Min...... ...:........Max.Operating Temperature *** �. Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Range 13 to+lao 2S to+so(CAN version* ao to+6o F/ c ..-. . ........................................... .......................................................................................... Superior efficiency(98%) Protection Rating. NEMA 3R •For other regional settings please contact solarld a support. Small,lightweight and easy to install on provided bracket Limited to 125%for locations where the yearly average high temperature isabove 77-F/25-C and to 135%for locations where it is below 77-F/25'C For detailed information,refer to httm//www solaredae us/files/odfs/nverter do overs z'ne eu de odf Built-in module-level monitoring - - ;,•A higher current source may be used,the inverter will limit its input current to the values stated. . ••CAN P/Ns are eligible for the Ontario FIT and microFIT(microFlT exc.SE1140OA-US-CAN). - Internet connection through Ethernet or Wireless outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled AC/DC Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 stmsc�c USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL WWW,solaredge.Us s; loom r 'fWECHANICALSIPECIFICATI 1 i Format 65.7 in x 39.4in x 1.57in(including frame) I a,o .,.>•o.m m., _ _ 0 min x 0 in) s,..o•�:.,,.,n t' (1.09 minx 100 4 m- ,- Weight r 44.09Ib(20.0 kg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass - - o-,,,,,ne� r I t , with anti-reflection technology °,1 T ( Back.Cover Composite film Frame Black anodized 7EP compatible frame _ a Cell 6 x 10 polycrystalline solar cells .- �s�••r"y.+:^" C Junction box Protection class IP67,with bypass diodes .-f'.� ..-=�``}J� Cable 4 mina Solar cable;W a47.24 in 0200 mm),(-)2:47.24 in 0200 mm) a Connector MC4(IP 68)or H4 �s I'~F' (IP68) ..rmmM O Ia.s.r.-mr r i1 "� [ '� • PERFORMANCE AT STANDARD TEST CONDITIONS(STC:1000 Wm',25 C AM 1.5G SPECTRUM)' N, • -. - .. PO 255 260 WER CLASS(+5W/-OW) flat 265 t � - -T- - -_ - - - _ _ _ f + Nominal Power P,vry (All 255 260 265.1 • E ' 1 • ' 'I Short Circuit Current - -I3, [A]- - - _ 9.07 w - 9t 15 ,. 9.23 . r Open Circuit Voffage _ Vec [v] - 37.54 - 3 7.7 7 38.01 Current at P,o, I_ [A] 8.45 8.53 • 8.62 at P1Oe V„w IV] 30 18 30 46 30.75 The new Q.PRO-G4/SC is the reliable evergreen for all applications,with - - _,_. . ._ r Efficiency(Nominal Power) 0 [%1 a 15.3 a 15.6 a 15.9 1 a black Zep Compatible TM frame design for improved aesthetics, opts- PERFORMANCE AT NORMAL OPERATING CELL TEMPERATURE(NOCT:800W/mx,45m3°C.AM 1.5G SPECTRUM)s lh . POWER CLASS(+5W/-OW) -. IWl 255 260 265 , mized material usage and increased safety.The 4 solar module genera- _. _ tion from Q CELLS has been optimised across the board: improved output. ` Shed Circuit _ Ps,� [A] 17.31 1920 _ 195,7 ' Short Circuit Current Isr [A] 7,31 7.38 7.44 yield,higher operating reliability and durability,quicker installation and +ipen CiryeRVetsge vne IV] 34.95 _ 35.16 - 35.38 more intelligent design. - - } Currenlat Psi I_ LA] 6.61 6.68 6.75 N, Voltage at P,sp Vu„- tV] 28.48 28.75 29.01 I . - _ 'Measurement.tolerances STC:s3%(P_);x 10%(I.,Vim,I_V_) 'Measurement tolerances NOCI-z5%(P_);x 10%(1",V_„1_,V_) INNOVATIVE ALL-WEATHER TECHNOLOGY PROFIT-INCREASING GLASS TECHNOLOGY OCELLS PERFORMANCE wARltaxTYf PERFORMANCE AT LOW IRRADIANCE •Maximum yields with excellent low-light •Reduction of light reflection by 50 At least 97%of nominal power during a.u. ^�° m ' and temperature behaviour. plus long-term corrosion resistance due t2 W° _,„ �,, ,amA�m firs[year.Thereafter max.0.6%de g ra- N s a --- ----- --- da[ion per year. , I •Certified fully resistant to level 5,salt fog to high-quality At least 92%of nominal power after 10 years. •Sol-Gel roller coating processing. 1 °8 ________________-- £ -= At least 83%of nominal power after c m -- -- ---------------- --- f ENDURING HIGH PERFORMANCE I W 25 years. 5 d ~ Long-term Yield Security due to Anti EXTENDED WARRANTIES I All data within measurement tolerances. • +" Full warranties in accordance with the rm xn em PID Technology',Hot-Spot Protect, •Investment security due to 12-year war anty terms of the Q CELLS sales IRRRaIRNCE fwhn•1 ,>" '"'" a '" • and Traceable Quality Tfa0". product warranty and 25-year linear . . m a organisation of your respective country. The typical change in module efficiency at an irradiance of 200 W/m2 in relation •Long-term stability due to VDE Quality performance warranty , 2 to 1000 W/m2(both at 25"C and AM 1.5G spectrum)is-2%(relative). ' r 4 ' Tested-the strictest test program- - - TEMPERATURE COEFFICIENTS(AT 1000W/NP,25-C,AM 1.50 SPECTRUM) - .J Claus f Temperature Coefficient at I5e a [%/K] +0.04 Temper atute Coefficient of V. 9 [%/K1 -0.30 res = �TOPBMpD PV - Temperature SAFE ELECTRONICS • Coefficient of P_ Y [%/K] -0.41 NOCT [°F] 113 t 5.4(45 t 3°C) P ! •Protection against short circuits and rhern thermally induced power losses due to 2014 Maximum system voltage Vrrs IV] 1000(1 EC)/600(UL) Safety Class breathable junction box and welded f Maximum Series Fuse Rating V [A OC] 20 Fire Rating C/TYPE 1 Cables. Max Load(UU'. [Ibs/ff21 50(2400 Pa) Permitted module temperature •40°F up to.+185°F W on continuous duty (-40°C up to+85°C) o Load Rating(UL)= [Ibs/R21 50(2400 Pa) 2 see installation manual - - QuslNy Teyyed -OG9ts ! 1 1 1' 1 .w„erwu, errt ryxm�seauR. - y�� 0L 1703,VDE Duality Tested;CE-compliant; Number of Modules per Pellet 25 IEC 61215(Ed.2);IEC 61730(Ed.1)application class ATHE IDEAL SOLUTION FOR': 10.40O32587 ...... Number of Pallets per 53'Container 32 ' aMPAl I e e Na° ee Number of Pallets per 40'Container 26 f]oa/toParrays on - .. �1P°�_ r ]J pOMIPA> p E C Pallet Dimensions(L x W x H) 68.0 x x 30 in x 0 m i) residential buildings Q � ♦ c u.„us � w, ",2caO• (1740 x 1130 x 1170 min) ' I Pallet Weight 1254 lb(569 kg) _ ' APT test conditions:Cells at•1000V a ainst United,With COndU[t1Ye metal foil covered Surface, ~FA 0v NOTE:Installation instructions must be followed.See the installation and operating manual a contact our technical service department for further information on approved installation and use of 8 Lp]yPpt� this product.Warranty void if non-ZEP-cedified hardware is attached to groove in module frame. 25'C.168h t See data sheet on rear for further information. Hanwha O CELLS USA Corp. '001 Irvine Center Drive,suite 1250,Irvine CA 92618,USA I TEL+1 949 748 59 961 EMAIL q-cells-usa®q<ells.com I WEB www.q{ells.us Engineered in Germany QG CELLS Engineered in Germany • OCE LLS a.