Loading...
HomeMy WebLinkAbout0038 SAINT JOHN STREET J TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map Parcel_ Application # Health Division Date Issued 12`ZZ Conservation Division Application Fee Planning Dept. Permit"Fee%'O, Date Definitive Plan Approved by Planning Board Historic - OKH 40 _ Preservation/ Hyannis A16 Project Street Address rid" -i-ham +' Village Owner_ C,\►��r— Address s6l len_ �, V\v c - T_ Telephone Uacoo Permit Request a_,, (z`S of --tvi ho wg' 1 n, o Crrn r�cc . (�caw.e c Le Square feet: 1 st floor: existing proposed 2nd floor: existing proposed —Total new Zoning District Flood Plain Groundwater Overlay G - Project Valuation �60 Construction Type_ Lot Size Grandfathered: ❑Yes ,J"o If yes, attach supporting documentation. Dwelling Type: Single Family )d, Two Family ❑ Multi-Family(# units) Age of Existing Structure �0 � r3- Historic House: ❑Yes /IA-No On Old King's Highway: ❑Yes Flo Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑Other !V� Basement Finished Area(sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full: existing new Half: existing - new -- Number of Bedrooms: existing _new Total Room Count (not including baths): existing new First Floor Room Count Heat Type and Fuel: ❑ Gas . ❑ Oil ❑ Electric ❑ Other Central Air: ❑Yes ❑ No Fireplaces: Existingk/f New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new si*&Pool: ❑ existing ❑ new size%07Barn: ❑ existing ❑ new siz Attached garage: ❑ existing ❑ new sizShed: ❑ existing ❑ new size Other: N n - Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ & _ Commercial ❑Yes $No If yes, site plan review# Current Use Proposed Use0y,_6L APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name � I� la-AIM Telephone Number 25� - &`��'�3��� Address 11. Ot ,a k-L4 o4g U License # 06 ` I CE (a /S \� 1L5 Home Improvement Contractor# Email Worker's Compensation # Dl�dd ALL CO RUCTION DEBRIS RESULTING OM THIS PROJECT WIL BE TAKEN TO 6L- 11�tnti p SIGNATURE DATE C96!S FOR OFFICIAL USE ONLY APPLICATION # DATE ISSUED r. MAP/ PARCEL NO. ADDRESS VILLAGE OWNER DATE OF INSPECTION: r FOUNDATION FRAME INSULATION FIREPLACE ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL GAS: ROUGH FINAL t FINAL BUILDING DATE CLOSED OUT .r ASSOCIATION PLAN NO. F-M '��' SolarCity. OWNI'R AIT 1'IIOMATION Job 9: Property Address: 38 St-John St Hyannis, MA 02601 I Eliene L. De Souza as Owner of the subject. property hereby authorize SOLARCITY CORPORATION to act on my behalf, in all matters relative to work authorized by this building permit application. signature of"Owner ate i . i I i s SOLARCITY.COM nZ faX: `t';TIl RCY e.t!,;�;tTtlN,�!•<,>),GA IiCa??,.OIrf,Cq ry C;:Otw;CG327"r;t°tC:!25;tC5,DC V!ICI•t®:!,.C"f; 25P? ,Hi Ct•T07M.MA HIC!585iZM1v1EVIs;fFF:ttt,7,!;J faHll,:t?l1sP; Nil tdJHlGdI,IHIOGIu6LL0'+nECaCti�Yt'7,.UW CP.1641We C'vC21'PSnOZ VA hlu,i ti„�,,3n„I Tk'CI ZIGGY.i.t4'A SUlA19G'ti�S�Qlr5t)4A4r„`r3ggp„q p�,iSf)LAHCft�r COP,PpRAPIP�f.,�4l,i�Ir;H i$H�SEFtvE{), Viueilehuoerls Detmosmerrt of P41h'w,Softly 8oartt of oustailfto Ro toot-4 5 And Stamtards cords CS-108616 JASON PATRY 821 STEWART DRIVE Abington MIA OZI<Sl 02180/2019 i Office otCouomer Atfiin&ttosinas ReeolsUoa { 'HOME IMPROVEMENT CONTRACTOR I Regtatralion: 168572 Typn EXPIMUon: 3WD17 Supplamem SOLAR CITY CORPORATION JASON PATRY 24 ST MARTIN STREET OLD 2UNI UkLBOROUGK MA 01762 Uo&rseeretary rj —Jul r� Office of Consumer Affairs d Business Regulation �y; 10 Park Plaza Suite 5170 Boston, Massachusetts 02116 Home Improvement.Contractor Registration Registration: 168572 ' Type: Supplement Card � Expiration: 3/8/2017 SOLAR CITY CORPORATION + CHERYL GRUENSTERN -- - '- .24 ST MARTIN STREET BLD 2UNIT 11 - - ---- -- - - - MARLBOROUGH, MA 01752 - - - - ----------.-----------..-.--- Update Address and return card.Mark reason for change. sea i Ca 2441<5:to _ Address ° Renewal Employment F_?? Lost Card flee of Consumer Affairs&Business Regulation License or registration valid for individul use only OME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation r Registration: 16B572 Type: 10 Park Plaza-Suite 5170 Expiration: 3/8/2017 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION , CHERYL GRUENSTERN 3055 CLEAR VIEW WAY SAN MATED,CA 94402 Undersecretary --Not valid without signature The Commonwealth of Massachrrsefts Deparment of Industrial Accidents I Congress streets Suite 100 Boston,MA.02114 2017 www mass gav/d1a Workers'Compensation Insurance Affidavit:Builders/ContwactordElectrictass/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Infarmatton Please Print Lcaft NaMe(Bwincss/Organizatinir/individoat): 801BICity C41portat10n Address: 3055 Cfearview Way City/Statc/Zip: San Mateo,CA 94402 phone#: (888)785-24$9 Are rowan employer?Meek the appropriate hot: Type of project(required): I.141 am aempto v with 15,000employces(full a ndlor-pasatinw)-* 7. 0 New construction 2.[]t am a sale preprictor or partnership grid have no employees working for nu in 8. ❑11emodeling any capachy.(Na workers'comp.insurance Mgliirodl 3.a1 am a homeowner dain$'ell work myself.lNu.workets'camp.insnranceraquired.]t 1 ❑BuildinDemolg a 4.[][am a homeowner and will be hiring amtraeton to conduct M work on my property. i will I0 Build ing addition etsam that all entaraom aid=lmvc Kmti:cr;'eotnpensrtGon insurance or are sole 11.[]Electrical repairs or additions proprietors with no cngdoy=. 12.Q Plumbing repairs or additions So I am a genrxal ctanttactar and I have hired thesah-canuactors)McA on the attached sheet. I3.❑Roof repairs These sub-canlrariars have employees and have wrorkaa'comp.insurance t ti.Q We are a cagtoration and its officers have cm-raised their right of exemption per MGI,c. 14.❑� Otile,solar panels 15Z§1(4�sins we have no employees.[No svarinars'catigt.rasttrancc requirsd.l +Arty applicant that checks box dl must also till oat the section below showing their workows'compensation policy infonaarlan. t I iomeowners into submit this Affidavit Indietging they are doing all wort,and then hive outside.contractors must sttbnm a new arrMavit indicating strett tCoatra m that check this I=mast attactmd an mkli Tonal sheet showing the name of the sub-wniraotors vAd state whether or nat those entities have emloyees. If the sub-connectors have employees,they mast p►ovidc their wdikcts`cramp.policy rauvber. J am nit employer that is providing workers'compensation insurancefor sty employees. Bdov 1s 1he paf qy and jub site informatlan. Insurance Company Name:American Zurich Insurance Company Policy*or Self-iris.Lic.#: WC0182015-00 Expiration Date: 9/I/2016 Job Site Address: 38 Saint John Street City/Stateaip: Hyannis,MA 02601 Attach a copy of the workers'compensation postq declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,WA is a criminal violation punishable by a fine up to S 1,500.00 and/or one-year imprisonment,as wets as civil penalties in the fvrnl of STOP WORK ORDER.and a tune of rip to S250.00 a day against the violator.A copy of this statement stay be forwarded to the Office of investigations of the DIA for insurance coverage verification. I do hereby certi um*r the puss andpenalties of"perjury that floe Informadou provided above is true and corred ason Pa : December 11,2015 MGM Ofciai use only. Do hot write in this urea,fe be compided by t:t(,y or fawn official. City or Town: Permit/License d Issuing Apthorfty(cult:one): 1.Board of Health Z.Building Departmamt 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing inspector 6.Other Contact Person: Phone M e AC R17� BATE(MM01YYYY) ` CO CERTIFICATE OF LIABILITY INSURANCE 0811712016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHT'S UPON THE CERTIFICATE BOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRo H R S CONTACT MAR K&INSURANCE SERVICES AME: --._—..._.__.._._....... ._..._..: .-...... . . ...... _ 346 CALIFORNIA0ORNIA STREET,SUITE 13 PHONE N¢}� CALIFORNIA LICENSE NO.0437153 E-MAIL ,ADARE5,%........... .._....---.._..._....--..-- ..-----...-_...._ SAN FRANCISCO,CA 94104 MhY Shannon Scott 415-743-8334 ...... HmCq 998301-STNDGAWUE-15-16 INSURER A.Bch American Insurance Company 116536 Sol Iy Corporation INSURER B.NA NIA 3065 Clearvlew Way INSURER C:NA _ NIA - San Malec,CA 94402 INSURER D.American Zurich insurance Company. _ 40142 INSURER F! COVERAGES CERTIFICATE NUMBER: SEA-D027t3W"8 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INsR, TADDL b MR POLICY EFF POLICY EXP L7R TYPE OF INSURANCE POLICY NUMBER fMM=1YYYYI lVfiMlVpfyyyyjLIMITS A X 'COMMERCIAL GENERAL LIABILITY GLOO182016-00 0910112015 0910112D16 EACH OCCURRENCE $ 3,000,600 f_.. . ......� . DAMAGE TORENTED ;CLAIMS41ADE nOCCUR I. � X SIR:$250,ODD l ME D EXP(Anypnepersr l.... 5..... _........_ PERSONAL&ADV INJURY $ __ 3,000,OOD GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ __ 6,000,000 X� 1...:..1 PRO- POLICY 1..... LOG PRORUGTS-COMPWPAGG S-.. -.--- 6,0OD,000 OTHER. $ A AUTOMOBILE LIABILITY LP0182D17-00 09/0112015 09/0112016 COMBINED SINGLE LIMIT $ 5,000,000 .... X ANY AUTO I SODLY INJURY(Per person) S XALL DWNED SCHEDULEDAU I ( _ . _. AUTOS X TOS BODILY INJURY(Par accident).S x-_ HIRED AUTOS x AUTOS OAN� I I CROP �AMAGfe S COMPICOLL DED: S $5,W0 UMBRELLALfAB. OCCUR I ) } EACH OCCURRENCE 5 . _ I EXCESSUAB CLAIAiStdAQE I AGGREGATE OED RETENTION $ D WORKERS COMPENSATION rWC0182014-W(AOS) 09101f1D15 109/0112016 X I PER OTH• AND l.$?�STI_1T.E A YIN VG018M15-W(MA) 09/01/2015 409f0112016 ANYWROEETOR EXCWDFD7 CiITIVE NIA' ' ' E.L.EACH ACCIDENT S 4,0�,0110 OFfrCERR,tEMi3ER E%CLUDED? , � —._ ...._....._ ............. (Mandatory In NX) �WC DEDUCTIBLE S500,0W E L.DISEASE-EA EMPLOYE S. 1�000,ODO 'If describe under yyeeaa.. I •• _. ._.. .._ ._ 'DESCRIPTION OF OPERATIONS below ! E.LDISEASE-POLICY LIMIT $ 1,DD0,000 I i DESCRIPTION OF OPERATIONS I LOCATIONS 1 VSIICLES(ACORD far,Additional Remarks Sdreduie,may ba atrachod If mono space Is reQulredl Evidence of insurance. CERTIFICATE HOLDER CANCELLATION Shca0y Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3MClearview Way" THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services i CharlesMafmolejo �'—"�' �1 .--- 01988-2014 ACORD CORPORATION, All rights reserved. ACORD 26(2(H4101) The ACORD name and logo are registered marks of ACORD Solar=oo SolarEdge Power.Optimizer Module Add-On for North America P300 /'P350 / P400' - - '.ye �, P300. P350 P400 ' {for 60-cell PV {for 72-cell PV•' ' (for 96-cell PV` . - modules) modules) Y;- ;INPUT t ... • - " Rated Input DC Powe011 - ....300 350-,.,,,,,.,. - 4bo - ....W.• ........ .... ..........P... ..g.(.. p - Absolute Maximum In ut Volta a Voc atlowest tem erature) 48 ^.60 - ` MPPT Operating Range - 8 48 - 8 60 8.80 Vdc ` Maximum Short Circuit Current.(Isc) ' 30 Adc ' _ Maximum DC Input Current - 12.5 - Adc - ............................. ........ ................. .. ._ - ..; Maximum.Efficiency . .. ..... . . . 98II8` - c ,% ' , ,Wei c . ..... .......:........ ... ........ . . :..._en ..... : ...................... Overvoltage Category . r.. .- _ x. 10UTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) - �,r Mazimum Output Current - - A - 15 - dc..:: MaximumOutputVoltage 60 Vdc'! 10UTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) - - - - Safety Output Voltage per Power Optimizer -ok - Vdc " " • _ . ;STANDARD COMPLIANCE.. _ - EMC •' "'"'' - - FCC Par t15 Class.8,1 EC61000 6-2,1EC61000 6 3 Safety - - - IEC62309-1(class II safety)UL1741 . - - - ........ --.:.... ... ........ ..: ROHS , - •:, ...Yes - ..INSTALLATION SPECIFICATIONS - ;MazimumAllowedSystemVoltage:. `� - - ...............................................::........... .... .. .:..:. .:.:....... .......1000; ........... - .... ::.Vdc..:.. - '141x212z405/5SSz834x1.59- - mm/in. Dimensions(W xLz H)-' • - d:_ 'Weight{including Cables)......... ..:..:.........950/2:...... .......... ... ..... p Input Connector - .....,...MC4/A...... l/Tyco - Output Wire Type/Connector - ................................;.......D.. ouble Insulated AmphenoL Output Wire Length 095/30 I .12/39 . ..m/ft... '$ _+ Operating Temperature Range +. - 40..+85/40.+185 C/.. .Protection Rating Y .......:.. .......... IP65/NEMA4 ... :"• Relative Humidity - :..:.:.. .......................:. 0:100 .. ..... ............ I- - -.i: . _ -: n wage src oa•rM nn•mod�i•rAoa i mw�o sxau� i eaoo•Ma � � • t � �'�� � ..- r + PV SYSTEM DESIGN USING A SOLAREDGE , .. THREE PHASE • THREE PHASE v ,INVERTER SINGLE PHASE, 208V 480V - -• Minimum String Length(Power Optimizers) -- ,.J ........... ..................... ... .... .. - Maximum String Length,(Power.Optimizers) 25- _25 50 maximum Power per String - '' 6000- t 12150 5250 ............. ................ .... ,� r- 'r Parallel Strings of Different Len, or Onentations - Yes.. .................... ................. ........ ....... ... .. .................... i _ - mom a- g p•.. - • ty r tat�.A r -. - '�' t ,F "SoiarCity I ZepSolar Next-Level PV Mounting Technology Zep System for composition shin Le roofs P 9 r� ' � Interlock Ground Zep (K—L11ment J Zep Campabue PV U."u Roof Anadunent Array SYirl �pMPgT� Description PV mounting solution for composition shingle roofs CeMppt� Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structual and electrical bond Zep System has a UL 1703 Class"A"Fire Rating when installed using V� LISTED modules from any manufacturer certified as"Type 1"or"Type 2" Specifications • Designed for pitched roofs ., Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 t �., ® ,_ ^1So1arCitV ZepSolar Next-Level PV Mounting Technology E Components ""`'�•-Up-roof ,...` J Comp Mount Interlock Leveling Foot Part No.850-1382,: Part No.850-1388 Part No.850-1397 Listed to UL 2582& Listed to UL 2703 Listed to UL 2703 Mounting Block to UL 2703 Ground Zep Array Skirt,Grip,End Caps DC Wire Clip Part No.850-1172• Part Nos.500-0113, Pail No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com Listed to UL 2703' - t This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 02 27 15 ZS for Comp Shingle Culsheet Rev 04.pdf Page: 2 of 2 r I solar=ooa SolarEdge Power Optimizer g Module Add-On For North America P300 / P350 / P400 a PV power optimization at the module-level — Up to 25%more energy - - Superior,efficiencyl99.S%i — Mitigates all types of module mismatch losses;from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization i I —Fast installation with a single bolt — Next generation maintenance with module-level monitoring _ - Module-level voltage shutdown for installer and firefighter safety - - USA GERMANY +ITALY9- FRANCE JAPAN CHINA vISRAEL AUSTRALIA www.solaredge.us I solarK0 c� SolarEdge Single Phase'lnverters,- [� For North America SE3000A-US./SE38OOA-US/SE5000A-US/SE600OA-US/ SE76OOA-US/SE10O00A-US/SE11400A-US 0 - erte , f 2 r� 12' 5 r . Y a yy I The best choice for SolarEdge enabled systems Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Superior efficiency(98%) Small,lightweight and easy to install on provided bracket Built-in module-level monitoring Internet connection through Ethernet.or Wireless Outdoor and indoor installation } • - Fixed voltage inverter,DC/AC conversion only . Pre-assembled Safety Switch for faster installation 3 Optional—revenue grade data,ANSI C12.1 USAj GERMANY-1TALYq=PRANCE. JAPAN'CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us THE "Trinamount MODULE TSM-PD05.18 DIMENSIONS OF PV MODULE ELECTRICAL DATA @ STC unH:mm Peak Power Watts-PMAx(Wp) 250 1 255 f 260 l 245 A 941 Power Output Tolerance-PMAx(%) - 0-+3 Maximum Power Voltage-VMr IV) t 30.3 30.5 30.6 } 30.8 - mxcrron aox _ '�Maximum Power Current-IMry(A) 8.27 8.37 8.50 rw.,Evu.E o Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 � 38.3 ( - <es.,z Short Circuit Current-Isc(A) 8.79 8.88 9.00 9.10 Ixsrw,�xolr � �. E 1 Module Efficiency rim M 15.3 15.6 I 15.9 - 16.2 - STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN.60904-3. - typical efficiency reduction of 4.5%at 200 w/m'according to EN 60904-1. - - - - - � o ELECTRICAL DATA@ NOCTf - Maximum Power-PMAx(Wp) 186 t 190 j ,193 197 y - - �[Maximum Power Power Voltage-VMr(V) 28.0 28.1 28.3 28.4 f., _ Maximum Power Current-IMrr(A) 1 6.65 6.74 6.84 r. 6.93 _ 1 6e a3CdWH.1-ME - A A - �Open Circuit Voltage(V)-Voc(V) 35.2 35.3 35.4 35.5 iz oxAw Hou: - . Short Circuit Current(A)-Isc(A). �. 7.10 7.17 7.27 ( 7:35 NOCT:Irradiance at 800 w/.',Ambient Temperature 20°C.Wind Speed 1 m/s. 812 180 Back view MECHANICAL DATA r Solar cells 1 Multicrystalline 156 x 156 mm(6 inches) - Cell orientation iii 60 cells(6 x 10) Module dimensions 1.1650 x992 x 40 mm(64.95 x 39.05 x 1.57 inches) - - Weight 19.6 kg(43.12lbs) -- - - - Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass ' - f , w' BacksheeT White A-A 'Frame �Black Anodized Aluminium Alloy - - �J-Box IP 65 or IP 67 rated . 'Cables (Photovoltaic Technology cable 4.0 mm2(0.006 inches2), 1 1200 mm(47.2 inches) I•V CURVES OF PV MODULE(260W) Y Connector H4 Amphenol " =riw.' Fire Type UL 1703 Type 2 for Solar City - e.o0 ? 6.W wow TEMPERATURE RATINGS MAXIMUM RATINGS r a uw - ,.Nominal Operating Cell- ]44°C(+2°C) Operational Temperature t-40-+g5°C Temperature(NOCT) j ..� 1111 i 3,w _ {{{Maximum System 1000V DC(IEC) 4 _ x J Temperature Coefficient of PMAx -0.41%/°C #Voltage IOOOV DC(UL) t # t.w Temperature Coefficient of Voc -0.32%/°C - Max Series Fuse Rating 1 115A 6 to zo 30 afi w -Temrpe nature Coefficient of Isc ,0.05%/°C ,1 - WARRANTY CERTIFICATION - 10 year Product Workmanship Warranty f L Year Linear Power Warranty C YL BE Spy (Please refer to product warranty for details) 16TFD c us + w PACKAGING CONFIGURATION - ' a- COMPOA9T Modules per box:26 pieces - .Modules per 40 container:728 pieces, CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. GpKP4,,B 'r0�L ®2015 Trina Solar Limited.All rights reserved.Specifications included in this da}osheet are subject to uin-rill 11/yF^ change without notice. q Smart Energy Together zbnrnro Mono Multi Solutions O THE MODULE ' `R 6® CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 245-26OW PD05.18 POWER OUTPUT RANGE Fast and simple to install through drop in mounting solution MAXIMUM EFFICIENCY Good aesthetics for residential applications 0pw+37 - POWER OUTPUT GUARANTEE ! Highly reliable due to stringent quality control • Over 30 in-house tests(UV,TC,HF,and many more) As a leading global manufacturer • In-house testing goes well beyond certification requirements of next generation photovoltaic products,we believe close cooperation with our partners is critical to success. With local presence around the globe,Trina is able to provide exceptional service to each customer in each market ` Certified to withstand challenging environmental and supplement our innovative, ) conditions reliable products with the backing • 2400 Pa wind load of Trina as a strong,bankable - partner. We are committed • 5400 Pa snow load to building strategic,mutually beneficial collaboration with installers,developers,distributors and other partners as the backbone of our shared success in driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY Trina Solar Limited 10 Year Product Warranty•25 Year Linear Power Warranty www.trinasolar.com d i 00% AdtllHonal 0 o Solpr's�Ilnec., vplvehOm Trlhvon rpn ytO 4ronasolar eon Smart Energy Together 'Year: s io rs 20 25 Trina standard - 13 Inrlusny standard THE Yrinamount MODULE TSM-PDO5.18 - DIMENSIONS OF PV MODULE ELECTRICAL DATA @ SIC i. unit:mm Peak Powerwatts-PMAx(Wp) 245 T 250 I - 255 260 941 j Power Output Tolerance-P.Ax(%) - 0-+3 Maximum Power Voltage-Vnr(VI 29.9 30.3 30.5 30.6 ,uxnroN o 'i o eox Maximum Power Current-IMPP(A) 8.20 8.27 8.37 8.50 f 1 r { P`HE J Open Circuit Voltage-Voc(V) I 37.8 38.0 1 38.1 I 38.2 !! Itt LLL xou �Short Circuit Current-Current-Ix(A) 8.75 8.79 8.88 9.00 `i srnw"c n Module Efficiency qm(%) Z 15.0. 15.3 ^. � 15.6 �. 15.9 r STC:Irradiance 1000 W/m2.Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. p Typical efficiency reduction of 4.5%at 200 w/m2 according to EN 60904-I. s - o 0 ELECTRICAL DATA®.NOCT ' Maximum Power-Pwx(Wp) r 182 7 186 '. 190 ). '193 - - r Maximum Power Voltage-Vw(V) 27.6 - 28.0 28.1 28.3 se..,csouNomc NOES E Maximum Power Current-l-P(A) I. 6.59 6.65 I 6.74 6.84 - 1 A A r:-oav-1 Open Circuit Voltage(V)-Voc(V) 35.1 35.2 35.3 35.4 - Short Circuit Current(A)-Isc(A) _ 7.07 { 7.10 E 7.17 7.27 - NOCT:Irradiance at 800 w/m',Ambient Temperature 20°C,Wind Speed I m/s. 812180 I - Back View MECHANICAL DATA 11 - Solar cells ,Multicrystalline 156 x 156 mm(6 inches) Cell orientation 60 cells(6 x 10) I - Module dimensions 1 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) - 1 Weight 1 21.3 kg(47.0 Ibs) ` Glass - 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass - A-A P White . . . . k Backsheet Frame I Black Anodized Aluminium Alloy with Trinamount Groove • , ' I-V CURVES OF PV MODULE(245W) !J-Box IP 65 or IP 67 rated t Cables I Photovoltaic Technology cable 4.0 mm'(0.006 inches'). - I.m.m 9 1 1200 mm(47.2 inches) Fire Rating Type 2 ^Bro 8�W/mP2 Q 61 m - _ `c as 5.- 4.m 4 TEMPERATURE RATINGS MAXIMUM RATINGS 'U 3- 200 200w/m' Nominal Operating Cell �4o. OperationalTemperature�-.-40-+85°C W Temperature(NOCT) .1 '44°C(±2°C) Y 1 Maximum System 1000V DC(IEC) O.m 10.m 20.m 30.0° Temperature Coefficient of P- -0.41%/°C Voltage 1000V DC(UL) . - m 111 Voltage(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A Temperature Coefficient of Isc 0.05%/°C - - - - WARRANTY . ~ 10 year Product Workmanship Warranty Y 25 year Linear Power Warranty J ,5 .. )Please refer to product worranty for details)T--.- CERTIFICATION • PACKAGING CONFIGURATION a - 16TEn c s. Modules per box:26 pieces w Modules per 40'container:728 pi ecess E I E - - '- COMPt1ANT CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. aanP4�0-7// ��o�a�solar 02014 Trina Solar Limited.All rights reserved.Specifications included in this datosheet are subject to change without notice.Smart Energy Together 1 i i Mono Multi Solutions 0 THE UNRE. Mount MODULE � l 60 CELL MULTICRYSTALLINE MODULE - -_ PD05.18 WITH TRINAMOUNT FRAME 250 265W POWER OUTPUT RANGE Fast and simple to install through drop in mounting solution 16.2% MAXIMUM EFFICIENCY Good aesthetics for residential applications o*, ® 30 POSITIVE POWER TOLERANCE. Highly reliable due to stringent quality control • Over 30 in-house tests(UV,TC,HF,and many more) As a leading global manufacturer • In-house testing goes well beyond certification requirements of next generation photovoltaic 9 p PID resistant products,we believe close cooperation with our partners is critical to success. With local presence around the globe,Trina is able to provide exceptional service to each customer in each market r Certified to withstand challenging environmental and supplement our innovative, ! conditions reliable products with the backing �. / • 2400 Pa wind load of Trina as a strong,bankable • 5400 Pa snow load partner. We ore committed to building strategic,mutually beneficial collaboration with installers,developers,distributors and other partners as the backbone of our shared success in driving Sma rt Energy Together. 'LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty•25 Year Linear Power Warranty Trina Solar Limited www.trinasolar.com r,roox a Addlt- hcf volue iro vast , rhTrtnoSolarsllnearNarron o ly Tron-asolar ea� } r w Smart Energy Together Years s to Is. 20 2s Trinastandard IJ Industrystandartl ry $Q Jar MO Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US SE3000A-US SE380OA-US SE5000A-US SE6000A-US .SE760OA-US SE16000A-US SE11400A-US OUTPUT r Nominal AC Power Output- 3000 : 3800 5000 6000 7600 11400. VA '• _ ..T.........:......... ........ ... .::. - - : 0V 10000 24 ° - 5400 @ 208V 10800 @ 208V - Max.AC Power Output 3300 4150 - 6000 - 12000 - 5450 @240V•• ........ ........ ..: .....•10950.V240V _ .. AC Output Voltage Min:Nom:Max!I ! _ ! 183-208-229 Vac "• • SAC Output Voltage Min:Nom:Max l'I !i ! ! ! ! ! !• _ - , 211-240-264 Vac - AC Frequency Mm Nom Max I I 59.3 50 60.5(with HI country setting 57 60 60.5) . Hz 24.@ 208V @ 208V Max Continuous Output Current 125. ...I .....?6.. .L•21•�a•240V .I..... 25••• ••I.••. 32......:I.. :42 @.240V•••I• 475:•:.• A GFDI Threshold" - ...:........................'........ ..:... ... .........:............................................ ........... .............................'... ........ A.....: • Utility Monitoting,Islanding Protection,Country Configurable Thresholds Yes, Yes 4 I INPUT ..',• `.1 Maximum DC Power(STC) 4050. 5100. 6750 8300 10250 13500: '15350 W' - ........................................... ... - ......... Transformerless,Uhgrounded - - Yes - • ................................._. - ._....... ........... ... .. Max,Input Voltage..................... ........................ . - Nom:DC Input Voltage - - _ 325 @ 208V/350 @ 240V ' Vdc 16 5 @ 208V 33 @ 208V Max.InputCurrentl7l ...95. ..) ..,..13.... L.15.S.�a 240V..I..... 18......I. ...23... .;I•_305�1p 240V••I,••• 34....... .. .... ............................... _ Max.Input Short Circuit Current - - - ............................._............. ......... .............I........... ..: .......... ....45................... .,_............ .Ad c.... .. • Reverse-Polarity Protection _ - ••„.,••..Yes - ' ......I......... ... ......... ............. ..GroundFaul[IstilationDetection .......'.•..:..'.'.................. .. Y••• ..-.. - -. - 600ko Sensitivity : e-, Maximum Inverter EC Weighted Efficient YencV• ....... : .. 97.5.... I ...99 Z......I.97. @•2 0 V..�. ..98 5.....L....97.5.,..... .97 @$08V 97.5 /o - - •975@240V..I• - - Nighttime Power Consumption •<2.5 '' - <4 ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) - -. .........................................., .. .. Revenue Grade Data,ANSI C12.1 - - Optional - - - - ..................... ..................:.............'......................................:................. ....... .. Rapid.Shutdown—NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed("' STANDARD COMPLIANCE ':a Is; Safety -. :' UL1741 UL1699B,UL1998,CSA 22.2 '.. . .:.......................... ... ._.............. ...:...:. ........... •Grid Connection.Standards • IEEE1547 - .................. ... . ......... .....,................ ..::.............................. ... ........... Emissions - FCC part15 class B - INSTALLATION SPECIFICATIONS' 1. AC output conduit size/AWG range . 3/4"minimum/16-6 AWG = 3/4"minimum/8-3 AWG. ° .. .............. .............. .. . ....... . ............................... .......... .... .......... .......... DC input conduit size/k of strings/- 3/4'minimum/1-2 strings/ ' 3/4'minimum/1.2 strings/16-6 AWG - .AWG•range...................:........ 14-6 AWG.......... Dimensions with Safety Switch 30.5 x 12.5 x-7.2/775 x.315 x 184 30.5 x 12.5 x 10.5/ in/ HxWxD : -775 x 315 x 260 min ., Weight with Safety Switch.•;•••••••..• .• ,,.. 51.2/232• ............- I. •.. :_54,7/24.7 , ..:•....•••••.•, 88 4/401 lb/.kg..• - .. ... Natural ' - . - .. convection - Cooling_.' - Natural Convection '• and internal Fans(user replaceable): fan(uses ...................:........:.............. . :..-.....:...:................................. .replaceable).............. Noise Min:Max.Operating Temperature :13 to+140/ 25 to+60(-40 to+60 version availablelsl) - °F/-C Range....:.............................. ........................................... Protection Rating - . NEMA 3R - - .................................... ....... Y.... ............................................................... .......... Itl For other regional settings please contact SolarEdge support: - - - klAhighercurrentsourcemaybeused;the inverter Will limit itsinput current to the values stated.Revenue grade inverter P/N:SE—A-U5000NNR2(for 760OW inverterSE76MA-US002NNR2). - 14)Rapid shutdown-kit p/N:SE1000-R50-Sl. }. - _ Isl-40 version 4/N:SE—A-U5000NNU4(for 760OW inverter•SE7600A-U5002NNU4); - ' M t ,fit SLIf15PE �' — �l • TOWN OF BARNSTABLE BUILDING DEPARTMENT 1 COMPLAINT/INQUIRY REPORT Date 1 Rec'd By Assessor's No. 3 Last Name A)II4. First Name ORIGINATOR Street Village State Zits Telephone: Home 7` / // 20) Work Description: _ COMPLAINT s INQUIRY fa/ LIZ Al Requestor's Signature COMPLAINT Street Address L I COK LOCATION A= OFFICE USE ONLY INSPECTOR'S Date— G Inspector ACTION/ COMMENTS 9 .0'. &4 44- r ^ i FOLLOW-UP ACTION ADDITIONAL INFO. ATTACHED COPY DISTRIBUTION: WHITE - DEPARTMENT FILE YELLOW - INSPECTOR PINK - INSPECTOR (RETURN TO OFFICE MGR.) NISC1 'ROPERTY ADDRESS (STATE KEY NO. LOPJING DISTRICT CODE SP-DISTS.I DATE PRINTED CLASS I PCs I NSHD -d-�BELyI1FJS.AZIQLLNSIH9. UU38 SAINT JOHN STREET 07' RB 40C 07HY 07/09/95 1011 OJ 62AC R291 0:38. ��— i ,199154 LANDIOTHER FEATURES DESCRIPTION ADJUSTMENT FACTORS T lentl By/Dale Size o:mer>on —iLOC./VR_SpEC.CLASS AD.1. COND. vP RICE IT AD PRICE IT ACRES/UNITS VALUE Desc.ipron t)I LT O ON MI C H EL E T R MAP— /�_ FF.Deptn/Aeres E 4 L AND 1 20,100 CARDS IN ACCOUNT — 10.18LDG.SIT. 1 X .33 =100 1203 29999.9 60899.9 .33 20100 #3LDG(S)—CARD-1 ' 1 40,.000 � 01 OF 01 40THER FEATURE 1 2,600 Cusi 627UT;� BATHS 1 _0 U x C= 100 3500-OC 3500.0 1_00 1 3500 3 #PL ST JiJHN ST MARKET 67100 FIREPLACE U x C= 100 3100.0r, 3100.D0 1.190 j 31OU 3 I #DL LCT. E INCOME A jRGI DErGAR S 16 X 20 ; 196 C= 42 K 19.3' 0.1 c 320 2600 F #RR 1407 0110. SE DI APPRAISED VALUE i J i I 62,700 U I (PARCEL SUMMARY A11}D 20100 T IO-IMPS LDGS 40000 MII 2600 TOTAL 62700 N N CNST - DFEDREFERENCE, CATF_ RIOR YEAR'VALIJE T I i �>Ps Recortlatl Inst. Sales Price Bwh Fa el MD. v.. q C AND 20100 S i 9204/C11: Ii05194 L 29500 LDGS 42600 3414/305,TCI:01 /93 L 43600 OTAL 62700 8,996/323: 1:07192 L 39450 BDILDING peRMIT —" i°R G 1 VERY POOR.. Nemb6: Dare —T TyP_ Amo � .. _ L AND LATd —ACJ INC01ME SE SP—6 LDS FEATURES 8 L 0—A D J S� Ui`dITS I ImOOea�BDe�oOe®.� 20100 � i � 2600 6600 I l:rass - DoTPr•�1 Base Rate A4 Flare 1 _E It A Norm. Obsv. -- Unrls l.'nirs I - ' !�1 qe DP.Pr. Contl. CND I Loc °ro R.G I RlpI Cost New I Atll RePr Verue I Storie_ He�gm Rooms ytl Rms Belns sT Era. P+n ywail Foc 01C 000 100 100 58.65 58_65 63 65 29 66 90 56 71350n�'a 40000 1.0 5 3 1.0 4.0 Description Fare S4uare Feel Repl.Cosr MKT.INDEX(- 1 �U IMP.FSV/DATE' ME 1 0/37 SCALE: 11 00_86 ELEMENTS CODE' CONSTRUCTION DETAIL AS tU0 53.65 110E 64750 bNOSS—ARcW— N zLE r M LY DWELLING CNST GP:00 � ---------------------52--------------------* STYLE 03 ANCH - - 0_0 ! ES1GN ADJMT JU 0.0 e - XTER.WAWALLS 06 A LUm%VINYL Om0 12 EATIAC TYPE J2 `AS ___ 0.0 N! ! NTEZ.FIISH J4 RYWALL 0.0 ! ! I N7ERgLAYO0T 12 V9-R.7W694A1 0_0 24 BASE *----12---* IN7tR=OUALTY U2SAIPf€ AS €XTER_ 0.0 ! ! FCr3CR STRUCT 32kaD Jois77eE-AA - 0.0 D w ! EFLOiJR CUVER-- 05�CA-RPE1 b HAWD ff.0 E IbralAreas Base= 1104 °- 12 12OOF-TYPE I-j nS__LF-ASPa S H -6-0 JUILD:NG DIMENSIONS : E L C L I R I CAL _J -_ __ (1 0 T BAS W40 N24 c52 S 1 2 W12 S12 .. ! FOVYDAT-I-O-N J2 DidCREYE "BLOCK 99-.9 A *-----------------40--------^—^----X -------------- -- --------------------- - --'1EI--H8ORHJOD 62-AC-?fYA.NNTS ----- L LAND TOTAL MARKET PARCEL 20100 62700 AREA 1229 VARIANCE +0 +4998 STANDARD 25 RESIDENTIAL PROPERTY 4 MAP NO. LOT NO. FIRE DISTRICT SUMMARY STREET St'. John St. Hyannis _ LAND 2n1. 38 / _ H 7�. BLDGS. a A3p o OWNERe',. �eo-U:e.,:! -` 9 Ls�t�•.. ..,. TOTAL LAND RECORD OF TRANSFER DATE BK PG I.R.S. REMARKS: Lot E BLDGS. '- TOTAL Sarmiel.TT. .p nT,zo...n.,. w ..6 .. 1177. -1:93- LAND Hul , Annie P. 4/17/81 3271 293 ($1.00 , _,. _ � BLDGS. ( ° TOTAL X✓ V J�f�J���u^ LAND BLDGS. TOTAL LAND BLDGS. TOTAL LAND BLDGS. TOTAL LAND BLDGS. Q) TOTAL q. LAND INTERIOR INSPECTED: BLDGS. TOTAL DATE: LAND ACREAGE COMPUTATIONS BLDGS. LAND TYPE # OF ACRES PRICE TOTAL DEPR. VALUE TOTAL HOUSE LOT .5 Ilv J13 7oo t) 3 9 96) a b o LAND CLEARED FRONT BLDGS. REAR TOTAL WOODS&SPROUT FRONT LAND 'REAR BLDGS. WASTE FRONT TOTAL LAN D REAR � BLDGS. TOTAL LAN D A _ BLDGS. LOT COMPUTATIONS LAND FACTORS TOTAL FRONT DEPTH STREET PRICE DEPTH % FRONT FT. PRICE TOTAL DEPR. COR. INF. VALUE HILLY TOWN SEWER LAND ROUGHTOWN WATER BLDGS. HIGH GRAVEL RD. TOTAL LOW DIRT RD. LAND SWAMPY NO RD. BLDGS. TOTAL TOWN OF BARNSTABLE, MASS. - UNITED APPRAISAL CO., EAST HARTFORD,CONN. -- PURCH. DATE _ Conc. Slab Bsmt.Garage St. Shower Ext. Walls PURCH. PRICE . Brick Walls Attic FI. &Stairs ! Toilet Room Roof RENT •- •` - Stone Walls Fin.Attic L_/ Two Fixt. Bath - Floors 'iers INTERIOR FINISH Lavatory Extra 3smt. GI r� 1' 2 3 Sink f tit-v <//29 % r/Z '/ Plaster Water Clo. Extra Attic EXTERIOR WALLS Knotty Pine Water Only S-0 ' )oubla Siding,rC(4vl Plywood No Plumbing Bsmt. Fin. Tingle Siding Plasterboard Int. Fin. 'p5� ) Shingles TILING :onc. Blk. G F P Bath Fl. Heat r�0'-0 :ace Brk.On Int. Layout Bath fX.&Wains. Auto Ht. Unit -4- - '-/0 3 - o Bath FI. &Walls Veneer int.C nd. J — Fireplace :om. Brk.On HEATING ToiletRm. Fl. - Plumbing iolid Com. Brk. Hot Air Toilet Rm.FI. &Wains. - - Tiling Steam Toilet Rm. FI. &Walls 31anket Ins. Hot Water St. Shower goof Ins. Air Cond. Tub Area Total Floor Furn. ROOFING COMPUTATIONS ksph_Shingle v"_ Pipeless Furn. / J/ S.F. 'Nood Shingle No Heat S.F. ksbs. Shingle Oil Burner �'7i/ Y / S. F. Slate Coal Stoker S.F. rile Gas R S. F. OUTBUILDINGS ROOF TYPE Electric fable Flat S.F. 1 2 3 4 5 1 6 7 8 9 10 1 1 2 3 4 5 1 6 7 8 9 10 MEASURED Hip Mansard FIREPLACES S.F. Pier Found. Floor Gambrel Fireplace Stack y / Wall Found. 0.H. Door LISTED FLOORS Fireplace ". / Sgle.Sdg. � Roll Roofing Conc. LIGHTING Dble.Sdg. Shingle Roof Earth No Elect. DATE Pine Shingle Walls Plumbing _I Hardwood ✓ ROOMS Cement Blk. Electric Asph.Tile Bsmt. 1st TOTAL n '7(J-/) Brick Int. Finish PRICED J Single 2nd 3rd FACTOR REPLACEMENT OCCUPANCY CONSTRUCTION SIZE AREA CLASS AGE REMOD. COND. REPL. VAL. Phy.Dep. PHYS. VALUE Funct.Dep• ACTUAL VAL, D VV LG. I'"L� ., /- i�Al _ `-� ?77" / 2 9 3 G1'/E G- l G G s` 1 /7 P 9 3' - /%9 a UkA _ J t � = 2 } 3 I 4 — - 5 - - 7 1 8 to ;;: TOTAL Z0300 ej ' ` n�� I /c`/ � �. y� �� E y � ������ aI r f f f i __. _ f , i '14A{ . . � ,. .�.s7:-.L:.31 t Version#49.2 Q\�!a o :SOearClt m October 27, 2015 Project/Job#0261961 RE: CERTIFICATION LETTER Project: Souza Residence 38 St-John St Hyannis, MA 02601 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= MA Res. Code,8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf - MPl: Roof DL= 10 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL= 21 psf(PV Areas) - MP2A: Roof DL= 13 psf, Roof LL/SL= 21 psf(Non-PV Areas), Roof LL/SL= 21 psf(PV Areas) - MP26: Roof DL= 10 psf, Roof LL/SL = 21 psf(Non-PV Areas),Roof LL/SL= 21 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss =0.18757 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res.Code,8th Edition. Please contact me with any questions or concerns regarding this project. JASON WIL IAM � TOMAN 0 PRUCTURAL Jason W.Toman, P.E. "o No.51554 lft- Professional Engineer 4c, T: 480-553-8115 x58115 email: jtoman@solarcity.comIdtV AL. �G by Jason Toman Date:2015.10.27 20:52:29-07'00' 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028 (888)SOL-CITY F(650)638-1029 solarcity.com AZ ROC 24377i.CA CSL8 888104,CO EC 8041,QT HIC 0632778,OC HIC T1101486,DCC HIS 71101488,III C17-29770,10A HIC tI36672.MO 0.MHIC 128948.NJ 13vi imr,0600, OR COB 180498.PA 077343,TX TULI4 27006,WA GOU SOLARC'91907.O 2013 SO tCity.All rphtarese'ved. FIRM WR • .• ri JF -ice ► �;.. �; •n.4 r .a - -.. �. f r _ _ y♦� .. ,# a-a 1pr � „x r� •+ - � �' � 1' .,q �� k<<'. f i 1 f g • , a. of `�: :: W . r it it � t • Lt DigitalGlobe, MassGIS, Commonwealth of Massachusetts EOEA, USDA Farm Service Agency !. sSTRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 �' Member Properties Summary MPi Horizontal Member Spans Rafter Pro erties Overhang 0.66 ft Actual W 1.50" Roof System Properties San 1 11.39 ft Actual D 5.50" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofing Material Comp Roof_" San 3 A°,-` 8.25 in.A2 Re-Roof No San 4 S. 7.56 in.A3 Plywood Sheathing Yes San 5 I 20.80 in.A4 Board Sheathing None Total Rake Span 13.30 ft TL Defl'n Limit 120 Vaulted Ceilingv ' No PV:1°Start ft =, r Wood Species x . SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 12.50 ft Wood Grade #2 Rafter Slope -250 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 1 135 psi Top Lat Bracing ^. Full PV 3 Start �x ttu, . E'k. 1400000 psi Bot Lat Bracing At Supports PV 3 End Em;,, 510000 psi Member Loading mary Roof Pitch 6 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.0 Psf x 1.10 11.0 psf 11.0 psf PV Dead Load M PV-DC. 3.0`psf .0 x 1.10 ,,M, 3.3 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load LL SL1,2 30.0 psf x 0.7 1 x 0.7. . 21.0 psf 21.0 psf Total Load(Governing LC TL 32.0 psf 1 35.3 sf ---] Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per.ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(CO(IS)pg; Ce=0.9,Ct=1.1,Is=1.0 Member Design Summa (per NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1.00 0.58 1 1.3 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 45 psi 0.7 ft. 155 psi 0.29 D+S Bending +)Stress 1197 psi 6.4 ft. 1504 psi 0.80 D+ S ,Bending - Stress -18 psi 0.7 ft. -868 psi 0.02 D+ S Total Load:Deflection 0.73 in. I . 205 6.4 ft. 126 in. 120� 0.58 n - D+S 3 ' [CALCULATION_OF DESIGN WIN D_LOADS-MP1 t — Mounting Plane Information Roofing Material Comp Roof FVrSystem T�ype � e. E " i Tr Of Y,SleekMountT _. Spanning Vents No Standoff Attachment`Hardware Como Mount Tvne C Roof Slope 250 Rafter_Spacing _ _16 O.C. Framing Type Direction Y-Y Rafters Furlm Spacing 'A7X Purlins_Only - _ _ NA . Tile Reveal Tile Roofs Only NA Tile Attachment System ;Tile Roofs Only r Standin Searn)Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method :; fl ' Partially/Fully ER46PRNOod Basic Wind Speed V 110 moh Fig. 6-1 Exposure_Category _— _ C Section 6.5.6.3 Roof Style _ _ _ �Gable Roof -- i~ rt Fig.6-11B/C/D-14A/B Mean Roof Height r o h !� 15 ft -- Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure ___. KZ __ _ 0.85- Table 6-3 Topographic Factor_ w Krt -- 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4— Importance Factor' I 1.0 �� x Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC (Down) 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure P p= qh(GC ) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 10.1 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing. Landscape 64" 39" Max_Allowable.Cantilev_er. •._Landscape _ 24' NA Standoff Confi uration Landscape Staggered ~�- Max Standoff Tributary Area, _ Trib 17 sf_ _ PV Assembly Dead Load W PV 3.0 psf Net,Wind,Uplift at:Standoff� „ T actual •a. Uplift Capacity of Standoff T-allow 500 Ibs Stand Demand/Capacity DCR 62.3% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 6511 Max Allowable.Cantilever t _• ' Portreit„,�,,;� ° -- ._..;.-.. m 20°....:.yam°`�:,�,,._.__,._ �,��� ._..._�._._:NA., �` . Standoff Configuration Portrait Staggered Max Standoff Tributa Area_ Trib ��_ —22 sf PV Assembly Dead Load W-PV _ 3.0 psf Net Wind Uplift at Standoff _ —�T_actual_ _ - _ - -388 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff and/CaDacitv DCR 77.7% =a iSTRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- M1P2AT Member Properties Summary M02A Horizontal Member Spans Rafter Pro erties Overhang 0.66 ft Actual W 1.50" Roof System Pro erties San 1 11.54 ft Actual D 5.50" Number of Spans(W/o Overhang) 1 San 2 Nominal Yes Roofing Material Comp Roof San 3 A 8.25 in.A2 Re-Roof No Span 4 S. 7.56 in.A3 Plywood Sheathing Yes Span 5 IX 20.80 in.A4 Board Sheathing None Total Rake Span 13.46 ft TL Def'n Limit 180 Vaulted Ceiling j'.,'w Yes PVA'Start" 2.67 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 12.58 ft Wood Grade #2 Rafter Sloe 250 P.V 2 Start�,1 ` _ Fb ,:v : ,; 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start R E"4p 1400000 si Bot Lat Bracing Full PV 3 End Emig 510000 psi Member Loading Summary Roof Pitch 6 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 13.0 psf x 1.10 14.3 psf 14.3 psf PV Dead Load PV-DL 3.0 psf x 1.10 3.3 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load e LL SL112 30.0 psf w x 0.7 1 x 0.7 21.0;psf,w. 21.0 psf Total Load(Governing LC TL 35:3 osf 38.7 psf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)pg; Ce=0.9,Ct=1.1, IS=1.0 Member Design Summary(per NDS Governing Load Comb CD CL + CL - CF Cr D+ S 1.15 1.00 1 1.00 1.3 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 50 psi 0.7 ft. 155 psi 0.32 D+S Bending(+)Stress 1344 psi -6.5 ft. . 1504 psi 0.89.=n°. D+S Wending - Stress -20 psi 0.7 ft. -1504 psi 0.01 D+S Total Load Deflection s__«.; _` 0.85 in. 180 . a=6 4 ft •, �0.85 in. I U180 i1 00 aMs:.. D+S E i [CALCULATION•OF-DESIGN WIND LOADS_- MP2A_ Mounting Plane Information Roofing Material Comp Roof PV,System Type _ _. �; _ _ Soli rCity_SleekMounr' Spanning Vents No Standoff Attachment Hardware TM Como Mount Tvpe C !Y - Roof Slope 250 Rafter Spacing_--_ 16"O.C. FramingType Direction Y-Y Rafters Purlin Spacing _. _X-X Purlins,Onlyw .Y� " ----- -- NA _ Tile Reveal Tile Roofs Only NA Tile Attachment System {^ Tile Roofs Only <;u :r _ - - NA � „u Apt Standing Seam/Trap Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind,Desgn Method._ - ___w � Partially/Fully Enclosed Methods _ Basic Wind Speed ^ V 110 mph Fig. 6-1 Exposure Category__ _ C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6 3 Topographic Factor. r. s � "<y _ Krt _ :"n 1.00 � r�k'` Section 6 5 7. _ - ... Wind Directionality Factor ICd 0.85 Table 6-4 1.Importance Factor I `° 1.0 ,.. a `Table 6-1 Velocity Pressure qh qh _ 0.00256(Kz)(Kzt)(Kd)(V^2)(I)22.4sf Equation 6-15 Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC ooW 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p=qh(GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 10.1 Psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing_@r_._. _Landscape Max Allowable Cantilever Landscape. _.__._. _.__. . Standoff Configuration Landscape Staggered Max StandoffTributary,Area Tribe 17 sf PV Assembly Dead Load W-PV 3.0 psf Net-Wind-Uplift at Standoff _. T-actual -311 Ibs__ U_plift_Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci DCR 62.3% X-Direction Y-Direction Max Allowable Standoff Spacing _�Po Portrait 48" 65" Max Al lowable.Cantilever , ''::: Portrait �. x., :[ .. ___ ;,.20" °"` r Nq "' - - - Standoff Confi uration Portrait Staggered Max Standoff Tributary,Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoffs- T_actual,__-_ -388 Ibs Uplift Capacity,of Standoff T-allow 500 Ibs Standoff Demand Ca aci DCR 77.7% e 'STRUCTURE ANALYSIS- LOADING SUMMARY AND MEMBER CHECK- MP213 Member Properties Summary MP213 Horizontal Member Spans Rafter Pro erties Overhang 0.66 ft Actual W 1.50" Roof System Properties San 1 11.39 ft Actual D 5.50" Number of Spans(w/o Overhang) 1 San 2 Nominal Yes Roofina Material _y Comp Roof San 3 . .. A .8.25 in.A2 3 Re-Roof No Span 4 S. 7.56 in.A3 Plywood Sheathing x .: Yes i� ern San 5 w, .�; p -T I `°20.80 in.^4 Board Sheathing None Total Rake Span 13.30 ft TL DefPn Limit 120 Vaulted Ceiling 'No' PV 1 Start 2.50 ft WoodS Species SPF Ceilina Finish 1/2"Gypsum Board PV 1 End 12.42 ft Wood Grade #2 Rafter Sloe 250 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV:3 Start E 1400000 psi Bot Lat Bracing I At Supports PV 3 End Emi„ 510000 psi Member Loading mary Roof Pitch 6 12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.10 11.0 psf 11.0 psf PV Dead Load PV-DL 3.0 psf x 1.10 3.3 psf, Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load, LL SL 12 30.0 psf : A-x 0.7 1:x O.7 41, m. 21ffpsf., 1-210 psf , Total Load(Governing LC TL 1 32.0 psf 35.3 Dsf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)p9; Ce=0.9,Ct=1.1,4-1-0 Member Design Summa (per NDS Governing Load Comb CD CL + CL - CIF Cr D+S 1.15 1.00 1 0.58 1 1.3 1.15 Member Analysis Results Summary Maximum Max Demand @ Location Capacity DCR Load Combo Shear Stress 45 psi 0.7 ft. 155 psi 0.29 D+ S Bending + Stress - 1197 psi 6.4 ft. 1504 psi 0.80 D+ S Bending - Stress -18 psi 0.7 ft. -868 psi 0.02 D+ S Total Load Deflection 0.73 in. 205 6.4 ft. 1.26 in. 120 0.58 .f D+S j. q • P [CAL:CUL]kttON-OF'--Dtg!GN'Wi-NO'L6ADS-:'-MP29- Mounting Plane Information Roofing Material Comp Roof PV System T e s� Sola(q SleekMountT" Spanning Vents No Standoff Attache ment'liardware r Comu Mount Tvne C . . ak ., � R„. �7 �a Roof Slope Rafter Spac ing____ -. _ = µ_1620=C r n_ Framing Type Direction. Y-Y Rafters Purlmacin S X X Purlins Only NAuil p-- 9 - y4 Tile Reveal Tile Roofs Only .� NA� _ •�,-�...- �;�._ ,�„e.;.:>o-*.- ate.. "�"""�._...,- �+---'"..,.gym .-..."'�"'^` .- Tile Attachment System Tile Roofs Only_, Standin Seam/Trap Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 W nd,Designrethod�_ Basic Wind Speed V 110 mph_ Fig. 6-1 Exposure,,Category,._,,_ ,._. e_ __ C Section 6.5.6.3� _ Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h __ 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor K. 1.00 Section 6 5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down ,. .3 GC Down „ 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure P p = qh (GC) Equation 6-22 Wind Pressure U -19.6 psf Wind Pressure Down 10.1 psf ,ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable,Cantileyer Landsca_e �_ Standoff Confi uration Landscape Staggered Max Standoff Tributary Area J" Tribes: PV Assembly Dead Load W PV _ _ 3.0 psf Ne Wt ni d Uplift Standoffs F` T_actual _ - 311 Ibs - x� - . _ a Uplift Capacity of Standoff T-allow 500 Ibs ��----.---- .-t-.- _� �: sue;. �DCR�� „'a � �, _ � �4,G$2.3%ti�.. u: � x Standoff Demand Ca aci � 7t X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable_Cantilever � Portrait , �, � _,� _20" --NA_,,,__ Standoff Confi uration Portrait Staggered Max,StandoffTributary,Area. Trb -� � �,,a_,,_ __ 22:sf _ PV Assembly Dead Load W-PV 3.0 psf _ W Net WindlJWindUplift at Standoff actual -- ~ 4 T -388 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand Ca aci 4so, =DCR r 77.79/o u ABBREVIATIONS ELECTRICAL NOTES JURISDICTION- NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A, AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN, " EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. ; (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART..690.17. a` GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF ,THE GND GROUND MULTIORE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. , I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL ,. Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT. 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT.AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE` DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). a MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE` SCH SCHEDULE BONDED WITH EQUIPMENT-GROUND CONDUCTORS. S . STAINLESS STEEL STC STANDARD TESTING CONDITIONS ` TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc- VOLTAGE AT OPEN CIRCUIT f a ` WT WATT - 3R NEMA 3R, RAINTIGHT PV1 COVER-SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS ' PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO-BE DONE.TO THE 8TH,EDITION ELEC 1136 MR OF-THE Mk STATE BUILDING-CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH • THE 2014 NATIONAL ELECTRIC CODE-INCLUDING MASSACHUSETTS AMENDMENTS. e MODULE GROUNDING METHOD: ZEP SOLAR REV BY DATE COMMENTS AHJ: Barnstable REV A . NAME DATE COMMENTS r UTILITY: NSTAR Electric (Commonwealth Electric) ° PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-0261961 00 SOUZA, ADILSON SOUZA RESIDENCE Charlie Klein 7!0. CONTAINED SHALL NOT E USED FOR THE IarCltyBENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T e C PART TO OTHERS OUTSIDE THE RECIPIENTSp YP �318/ ST-cJOHN STg,06 Klltl PV ARRA`(ORGANIZATION, EXCEPT IN CONNECTION NATH MODULES H I ANNIS, MA 02601 ,THE SALE AND USE OF THE RESPECTIVE (31) TRINA.SOLAR # TSM-260PDO5.18 } 2a sn Drive,Building 2, Unit 11 'SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: - Marlborough, MA 01752 PERMISSION OF SOLARCITY INC INVERTER: SOLAREDGE SE760OA—US002SNR2 5088896437, COVER, SHEET PV 1 10/27/2015 T: SOLD) ITY(7°2B F: (65 w 638-1029 (BBB)—SOL—CITY(765-248s) www.solorcity.com PITCH: 25 ARRAY PITCH:25 MP1 AZIMUTH:283 ARRAY AZIMUTH:283 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 25 ARRAY PITCH:25 MP2 AZIMUTH: 103 ARRAY AZIMUTH: 103 AC © MATERIAL:Comp Shingle STORY: 1 Story Y U D O Inv 1 t \ D l m d _ — — STRUCTURE CHANGE a Front Of House N _ - LEGEND a A (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO g ln� & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC STAMPED & SIGNED AC DISCONNECT & WARNING LABELS FOR STRUCTURAL ONLY F(D] DC JUNCTION/COMBINER-BOX & LABELS `. DISTRIBUTION PANEL & LABELS J.ASON WIL IAM Lc LOAD CENTER & WARNING LABELS TOMAN 0 STRUCTURAL ran O DEDICATED PV SYSTEM METER LA 2o �, s, N4` 55 ® 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR o (E)DRIVEWAY SDI jJVA1. CONDUIT RUN ON INTERIOR Digl Jason Tornan GATE/FENCE U) Date:2015.10.27 20:52:07-07'00' 0 HEAT PRODUCING VENTS ARE RED t\ `t INTERIOR EQUIPMENT IS DASHED ' SITE PLAN N Scale: 3/32" = 1' E W 01, 10, 21' 5 CONFIDENTIALDENIIAL- THE INFORMATION HEREIN JOB NUMBER: -J B 0 2 619 61 00 PREMISE OWNER: DESCRIPTION: DESIGN: ■ CONTAINED SHALL NOT BE USED FOR THE SOUZA, ADILSON SOUZA RESIDENCE Charlie Klein ��,SO�afC�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 38 ST—JOHN ST 8.06 KW PV ARRAY NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C ',,` PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES. HYANNIS, MA 02601 TTHHE�SALE AND EXCEPT IN ITHE RESPECTIVE WITH (31) TRINA SOLAR # TSM-260PDO5.18 za s1.Manor Dew,Budding 2 Unit 11 T SHEET: REV: DATE: Marlborough,MA 01752 PAGE NAME SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: � T. (650)838-1028 F: (850)838-1029 PERMISSION OF SOLARCITY INC. SERTER: GE sE7600A—usoo2sNR2 5088896437 SITE PLAN PV 2 10/27/2015 (888)-SOL-CITY(765-2489) www.solarcNycom J1 STAMPED SI GNED M G E P FOR STRUCTURAL.ONLY JASON (E) LBW L IAt� �, TOMAN , E( ) LBW STRt1CTURA'L SIDE VIEW OF MP1 NTS10 , Q.5154Gistsa SIDE VIEW OF MP26 NTs t C MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES Jason Toman LANDSCAPE 64" 24" STAGGERED Date:2 .27 20:52:14-07'00' MP2B X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PORTRAIT 48" 20" LANDSCAPE 64" 24 'STAGGERED RAFTER 2X6 @ 16" OC ROOF AZI 283 PITCH 25 STORIES: 1 PORTRAIT 48" 20" ARRAY AZI 283 PITCH 25 ROOF AZI 103 PITCH 25 C.J. 2X6 @16"OC Comp Shingle RAFTER 2X6 @ 16".00 ARRAY AZI 103 PITCH 25 STORIES: 1 C.J. 2x6 @16 OC Comp Shingle f - PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER S 1 (E) 2x4 & FENDER WASHERS - LOCATE RAFTER, MARK. HOLE ZEP LEVELING FOOT (1) 'LOCATION, AND .DRILL PILOT ZEP ARRAY SKIRT (6) HOLE: (4) (2) SEAL PILOT HOLE WITH " ZEP COMP MOUNT C POLYURETHANE SEALANT. . ZEP FLASHING.C (3) (3) -INSERT FLASHING. WR 8'-1" 3'-6 (E) COMP. SHINGLE (1) . (4) .PLACE MOUNT. (E)- LBW {E).ROOF DECKING � (2) • .F �'_• • (5) .INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER: SIDE VIEW O F M P2A NTS STEEL LAG BOLT LOWEST, MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER . (6) B � _ -'BOLT'& WASHERS. (2-1/2" EMBED, MIN) MP2A X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (E) RAFTER LANDSCAPE 64" 24" STAGGERED 1 S 1 11NDOFF ,� PORTRAIT 48 2011 , RAFTER 2x6 @ 16" OC ROOF AZI 103 PITCH 25 STORIES: 1 ARRAY AZI 103 PITCH' 25 C.J. 2X6 @16" OC Comp Shingle PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-0261961 00 SOUZA, ADILSON SOUZA RESIDENCE Charlie Klein CONTAINED SHALL NOT BE USED FOR THE BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 38 .ST-JOHN ST 8.06 KW PV ARRAY �` ;Solarcity._ PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: H YAN N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH , .THE SALE AND USE OF THE RESPECTIVE (31) TRINA SOLAR # TSM-260PD05.18 24 St. Martin Drive, Building Z, Unit 11 .SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE I Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: T: (650)638-1028 F.- (650)638-1029 SOLAREDGE SE7600A 'US002SNR2 508889643T... STRUCTURAL VIEWS PV 3 10/27/2015 (88B)-SOL-CITY(765-2489) www.$daraitraam UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. f J B-0 2 619 61 0 0 PREMISE OWNER DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: ��� ■ CONTAINED SHALL NOT BE USED FOR THE SOUZA, ADILSON SOUZA RESIDENCE Charlie Klein -.,,SO�a�C�t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: w'a� y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 38 ST—JOHN ST 8.06 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: H YAN N I S M A 02601 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (31) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET: REV: DATE Madborough,MA 01752 SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE760OA—US002SNR2 5088896437 UPLIFT CALCULATIONS PV 4 10/27/2015 (888)—SOL—CITY(765-2489) www.solarcitycom' GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE " BOND (N) #8 GEC TO ONE (E) GROUND Panel Number:G2020MB1100 Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE# SE760OA-US002SNR LABEL: A -(31)TRINA SOLAR 26 TSM-260PDO5.18 GEN #168572 s ROD AND ONE (N) GROUND ROD AT Meter Number:44013734 Tie-In: Supply Side Connection Inverter; 760OW, 240V, 97.5�a w/, fed Disco and ZB, RGM, AFCI PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ' ELEC 1136 MR. PANEL WITH IRREVERSIBLE CRIMP Overhead Service Entrance INV 2 ` Voc: 38.2 Vpmax; 30.6 ' INV 3 Isc AND Imp ARE SHOWN IN THE DC'STRINGS IDENTIFIER �E 100A MAIN SERVICE PANEL E; 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER-HAMMER Inverter 1 Disconnect 1 4 100A/2P 3 SOLAREDGE Dc+ - �, ` A 40A SE760OA-US002SNR2 r DC. MP1,MP2 'ix16 -- EGC . A Lf zaov i B - L2 1 - N DG EGC/ DC+• +„ _ 3) (E) LOADS ND - - -- --- ---------- ------ --- .GEC 1N DG- .. C ,MP2: 1X15 M1 EGC--- ---------------_---- -- ---- -�� ---.--- G ------- --------- -� -J N 1 - (1)Conduit Klt 3/4' EMT g r '.. EGC/GEC _ GEC - TO'120/240V J SINGLE PHASE I 1 UTILITY SERVICE PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN ' e n - e. ,yq Voc* = MAX VOC AT MIN TEMP POI (1)Gro�gd Rod P A (1)CUTLER-HAMMER #DG222NR8 /� PV (31)SOLAREDGEO#P NA4AZS D� 5 B x 8, er Disconnect; 60A, 24OVac, Fusible, NEMA 3R /y PowerBox timizer, 30OW, H4, DC to DC, ZEP -(2)ILSCO/IPC 4�0- 6 (1)CUTLER-�IAMMER A DG100NB " Insulation Piercing Connector; Main 4/0-4, Tap 6-14 Ground/Neutral Kit; 60-10DA, General Duty(DG) nd - (1)AWG#6, Solid Bare Copper - s• S -(1)CUTLER-HAMMER #DS16FK ' SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Class R Fuse Kit -(1)Ground.Rod; 5/8" x 8', Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(2)FERRAZ SHAWMUT#TR40R PV BACKFEED OCP N ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL , Fuse; aoA 250V, pass RK5 ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE � 1 AWG#6, THWN-2, Black �' 1 AWG#8, THWN=2,.Black 2 AWG 0, PV Wire, 60OV, Blacks Voc*. =500 VDC Isc =15 ADC (1)AWG#6, THWN-2, Red O Igo(1)AWG a8, THWN-2, Red O (1)AWG #6, Solid Bare Copper EGC Vmp =350' VDC Imp=11.73 ADG (1)AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 . AAC (1)Conduit Kit; 3/4' EMT w -(1)AWG II6,.Solid Bare•Copper. GEC. • • •-0).Conduit.Kit;.3/4"•EMT • • • . , • • • • • , • • • • -(1)AWG�8,.TFtWN-2,.Green • . EGC/GEC•-(1)Conduit•Kit;.3/47•EMT. _ . . . • • • (2 AWG 10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC O (1)AWG , Solid Bare Copper EGC Vmp `=350 VDC Imp=11 ADC _ . . . . . . . . (1)Conduit Kit;.3/4'.EMT. .•. . � . . CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBQt J B-0 2 619 61 O O PREMISE OWNER: DESCRIPTION: DESIGN CONTAINED SHALL NOT BE USED FOR THE SOUZA, ADILSON SOUZA RESIDENCE Charlie Klein �:'�d Y EXCEPT SOLARCITY INC.BENEFlT OF ANYONE E MOUNTING ,GS M •. . NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C ` ' 38 ST-JOHN ST - Q .' S - SolarCity.PART TO OTHERS OUTSIDE THE RECIPIENT'S - � �H:O6 KW'PV ARRAYS " ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: H YAN N I S, M A` 026 01 THE SALE AND USE OF THE RESPECTIVE (31) TRINA SOLAR # TSM-260PDO5.18 24 st. Martin Drive,Building'2,Unit 11 'SOLARCTY EQUIPMENT, WITHOUT THE WRITTENNVERTER. PAGE NAME SHEET: REV: DATE ., Marlborough,MA 01752 PERMISSION OF SOLARCTY INC. ISOLAREDGE SE760OA-US002SNR2 5088896437 THREE LINE :DIAGRAM PV 5 10/27/2015 (esaj Sa�� 765-2489)6 sic°�«n Label Location: Label Location: Label Location: (C)(CB) iv lJll (AC)(POI) 1 v (DC) (INV) Per Code: _ Per Code: • Per Code: NEC 690.31.G.3 °o 0 o�ulp NEC 690.17.E �p° o ° - o• ,' NEC 690.35(F) ° o 0 0 •- TO BE USED WHEN Label Location: �� ' o•° ° �: - ° -o °-° • ° INVERTER IS O O OLD ; . (DC) (INV) UNGROUNDED D O Per Code: NEC 690.14.C,2 Label Location: Label Location: ° ° ° o• 'O o °� (POI) -o - (DC) (INV) _ - o Per Code: Per Code: -° D o Gam° o NEC 690.17.4; NEC 690.54 NEC 690.53 Label Location: ° n o l!l1�J� (DC) (INV) Per Code: NEC 690.5(C) o- -o� n °• ° Label Location: (POI) ° Per Code: NEC 690.64.B.4 jam Label Location: of ( (DC) (CB) Per Code: Label Location: NEC 690.17(4) (D) (POI) ��• o[>CJ:o �,p; ° 0 Per Code: o•o ° �$e :�}° NEC 690.64.6.4 Label Location: 0 0 (POI) _ Per Code: - - ° Label Location: 690.64.B.7 o 0 NEC O O O ( ) ( l:) (AC): AC Disconnect o • • (ACCode ° o (C): Conduit D O� NEC 690.14.C.2 ° (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect (AC) (POI) (LC): Load Center Per Code: (M): Utility Meter e- a NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Clearview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ,`1,,!, IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, �- San Mateo,CA 94402 Label Set ��•.�•� T:(65D)638-1028 F:(650)636-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /� SolarCity. (888)-SQL-OILY(765-2489)www.wlarciry.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC.