Loading...
HomeMy WebLinkAbout0320 STEVENS STREET (4) z • ,4 } n 77 s1 13 Y. q S 5-/ 139 , YS- , 5� 13y, yS ��- �1 -- S 77 � 5 h MARK R R4ARINACQO ARQdIT€G7: ARCHITECT :PLANNER CONSiXTANT - 19'KbMET:CMUL '.SANDW", NA 02583: :.5W8 420 0822 August 9,2007 Thomas Perry Building Commissioner 200 Main Street Hyannis, Massachusetts 02601 Re: Steven Street Residential Condominium Project Buildings: A, B, C `6 Dear Mr. Perry: Attached please find field reports for the residential condominium buildings A, B, & C, Stevens Street, Hyannis, Massachusetts. The work completed appears to have been done in conformance with the construction documents. If you have any questions or comments please feel free to contact me at 508420-0822. Sincerely C� i N Marc Marinaccio r -q' MARK R. MARINACCIO; :ARCHITECT ARCHITECT;S OWNER o ARCHITECT ARCHITECT + PLANNER + .CONSULTANT FIELD REPORT CON , TANT ; : ,,:MA 02583 .508.42o 0827 AIA DOCUMENT C717 FIELD PROJECT: BYa'kaWondguiinium 1ITnits,G4 C2,C3;Stevens StrCD REPORT NO ' 1 Permit Cl"B20071122;C2=B20071403;C3=B200714 CONTRACT: ARCHITECTS PROJECT NO 304005 DATE . 8-1-07 TIME 9:00 A1VI WEATHER Wit in/SuA TEMP.RANGE 80?s EST.'/o OF COMPLETLON C.QNFORMANCE WITH SCHEDULE(.+,-) . Pl m m HVA ''Elect : i u b C .M Tina c o David S 1 Sill Kell a c WORK* N�PROGRESS . � � � .O. i P O g. PRESENT AT. SITE. . g� .. Y�, 3be tambojoU Plumbing,Electrical,HVAC work 95%complete Na insulation woik has been started OBSERVATIONS General. Structural Rough Frame is Complete;fire.blocking;is installed'.at stairs and.unit:walls.:Ceiling:strappm :is complete,exterior,siding has.been installed,roofing installed,windows:,and doors installed. Fire rated:assembly has.beeninstalled around the:TJ1 floor joists where they sit on top bf the:fire rated bearing. wa Insulation and:.sheet.rock worlds,scheduled for.next week. UL.wall assembly details were:given to the project supervisor;:.Through plate and sill penetrations to be fire caulked in accordaniciyith the_plans Project upervisorstated that all vertical load.-have been carried.down 464he foundation to comply with :requirements.of structural engineers field:report: ITEMS TO.VERIFY 1. omp ete ire Caulk at t roux penetrations o . 18rg rx INFORMATION�OR ACTION.REQUIRED 1 Notification to the architect of the expected date of sheet insulation installation ATTACHMENTS MARK R�MARINA�WO, ARCHITECT ARCHITECT'S OWNER ARCHITECT 7n ARCHTECT PLANNER CONSULTANT FIELD (REPORT, CONSULTANT IJ 19 SCMM.p _ IM563 a03.420 082) AfA .DOCUMENT CM FIELD, PRO}ECT Hyannis Condominiam:><Tnrts Cl.Cl,G3;Stevens St LD REPE}RT NO .2 Permit C1=B20071.122;C2—B20071403;C3.=B200714 .:.CONTRACT: ARCHITECTS PR9JECT NO 34-2405 DATE .8-8-07 TIME. & 00 AM :. WEATHER Warm/Humid:.. tw'? RANGE 70's. EST: %OF COMPLETION CONFORMANCE WITH SCHEDULE WORK IN.PROGRESS.. Insulation& Al .e Caulkin�ESENT AT SITE. MarkMarinacclo,:David Sigl,Bill.Kelly. Insulation was installed in units Cl &C2 Insulation work was started in unit C3 but not complete OBSERVATIONS .. .. General 1. .3M_fire caulking is_being installed at: through top and bottom plate penetrations:�n fire separation: risen}lilies b�twe�;a units The following locations still regwre installation'of fire.caulking }a: Uni lisfFloor 2.; Plastie electric.boxes have been installed in the fire separation assemblies-between:units: Fire rated ellectric boxes are available.71t has_been requested-ma-Me e ec rcian submit suppor g . a 09ta s owing that ahe installer) hnxes comply with the UL,As-, lv :.:The;following locations need additional work. 4. :,5./8 type X;firecode sheet rock was observed i .m umt Cl,waiting for installation. \S�ERED AR�y� ITEMS TO.VERIFY omp e e re a at first floor unit ;,ta t't3�8 2. Vilir ICafioilr of UL rated electric box installation.av� INFORMATION OR-ACTION.REQUIRED .1 Notification to the architect of the expected date of sheet rock installation A'iTACMMEN?`S . MARK R. MARINACGO," ARCHITECT ARCHITECT'S OWNER" ❑ ARCHITECT G� ARCHITKT i PLANNER + CONSULTANT FIELQ .REPORT CONSULTANT ,9 h1A oz563, sos.420"0822 AIA DOCUMENT C711 FIEi4 PROJECT yannis:Cgnda units A1,A2 A39,At AS FIELD 1REPORT NO 1 I. Steyens,Street CONTRACT: ARCHITECT'S"PROJECT NO 30-2005 DATE $-1-07 TIME. "9 00 ^AM WEATHER` Warm"fSun TEMP,RANGE $4's. " EST::% OF COMPLETION : : ," .:CONFORMANCE WITH:SCHEDULE wORK IN PROGRESS Rough Frame 95%o.Complete PRESENT AT sITE.MarkMarinaccio;David_:Sigl,"Bill Kelly; J.oe o No insulation work has been started OBSERVATIONS `.. General: 1.:Structural Rough Frame.is 95%0;exterior siding and triiihas been installed,roofing installed,:windows and, doors installed. 1." Ut wall assembly details were given tor the project supervisor; Through plate and sill penetrations to be Are. caulked in accordance.—W—ii e.p.ans RED�Ar ITEMS TO VERIFY ci. s w. Aw A.: INFORMATION OR ACTION.REQUIRED 9�T�ofPsgP 1. Obtain:structural engineers.frame inspection report ATTACHMENTS MARK R..:MARINACCIO: :ARCHITECT . ARCH ITECT'S OWNER Ca ARCHITECT ARCHIW- ..,PLANNER- .j:CONSULTANT FIELD REPORT CONSUL ;� ie SCONW,aeaF; .sMovuibi, MA, 025e3. .aos ago 0822 A►A .DOCUMENT C77i FIELD7 . Q PROJECT- 4 RYann�s..Ggnda iTnits Ill,B2,13, FIELD REPORT NO 1 Stevens,Street.'.. CONTRACT ARCHITECT'S PROJECT NO: 30-2005 DATE 8 -47 TIME :04 AM WEATHER Warm'/Sun TEMP;RANGE $4's. EST::% OF COMPLETION.: CONFORMANCE N/ITH;SCHEDULE(+ ) WORK IN PROGRESS_Rough Frame 95%o.Complete .pRESEnIT nT.51TE.Mark.lyMarmaccio;David_.Sigl,Bill Kelly; o oo _ No insulation work has.been started OBSERVATIONS General: 1. Structural Rough Frame.is 95°/0,exterior siding.and trim has been installed`,roofing installed;_windows and doors installed. 1. UL wall assembly details were given to the project supervisor; Through,plate and sill penetrations:to be fire cau e inaccor.ance with-the plans b. ITEMS TO .VERIFY 4��.� ��R/y�A/Y F,�L�AOUTH. w INFORMATION NO FOR H OF,MFSSP t Obtain structural engineers.frame.inspection report ATTACHMENTS Structural Engineering STRUCTURAL AFFIDAVIT FOR CONSTRUCTION CONTROL TO: Flagship Estates LLC Two Adams Place, Suite 100 Quincy, MA 02169 RE: Hyannis Condominium Development Stevens Street Hyannis, MA FC PROJECT No.: 0569 DATE: January 12, 2007 In accordance with the Massachusetts State Building Code Section 116.0,the engineer's authorized representative will make periodic field visits during the construction period for the above project and make observations of work in progress. Observations shall.be recorded per the CSI (Constructions Specification I i ute) standard format and furnished promptly to the Building Department and the Owner. OF sir r'. Lic. #42868 4 sTiRuc7uw� ST CY .FLOOD MASS. REG. NO. aON 16���E��►°��� STRUCTURAL . Subscribed and sworn to me this lc�k day of , 2007. 26a."X, �Qo-tcw N Y PUBLIC My Commission expires JOAN M.WORDELL - 2 NIMM Public 00 v, i 20 )_9 -� COMMONINEAUH OF MASSACHMM MY pommission Expires Nat rdw 1,2013 56 Laurel Drive • Hudson, MA 01749 • TEL: (978) 562-6499 FAX: (978) 562-6246