Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
02 2nd Flr (15)-0
© Streibert Associates - Architects Scale: 1/4" = 1' - 0" STREIBERT ASSOCIATES 15 Linden Tree Lane Chatham, Massachusetts 02633 Architects 508-945-1459 8 May 2022 2201Seashore Homes, Inc. 63 East Main Street Hyannis, MA 02601 2nd Floor Plan A2 8'-10"WD27 6'-10 3/4"12'-8 5/8"12'-8 5/8"28'-0" moved MovedBedroom Bath Living / Dining moved Bedroom Living / Diningdn8 1/4"R, 9"T12'-0"5'-0"1'-11 1/4"2 3/4" linen pantry 34'-0 1/2"3'-0"60 24 WD27Bath linen pantry 3'-0"6024WD27 BedroomBath Living / Dining 8 1/4"R, 9"Tdnlinenpantry 3'-0"60 24BedroomLiving / Dining WD27 Bath linen pantry3'-0"60 24 6'-0"5 1/2"28'-0" HVAC HVAC HVAC HVAC HVACHVACHVACHVAC 5'-6 1/2" 3030 30 30 Pole and Shelf Pole and Shelf Pole and Shelf Pole and Shelf D2 D2D2 D2 D3D3 D3 D3 D4D4 D4 D4 D5D5 D5 D5 D6 D6 D6 D6 D2D2 W7W7W7 W7 W7W7W7W7W9W9W7W7W7 W7W8W8 W8W8 Kitchen Hall Kitchen Hall Kitchen Kitchen Hall Nexistingnew existingnew LEGEND - Energy compliance New interior or exterior walls Interior Walls - 2 x 4 wood frame construction @ 16" O. C. with 3 1/2" unfaced fiberglass batt insulation between studs. Finish both sides with 1/2" gypsum wall board (GWB). Exterior Walls - 2 x 4 wood frame construction @ 16" O. C. with CertainTeed R21 unfaced fiberglass batt insulation, or equivalent, between studs with continuous vapor retarder on the interior face. Finish interior face with GWB. Exterior face shall have 1/2" OSB sheathing, housewrap fully taped, and siding material and coursing shall be as indicated on exterior elevations. Roof Framing - Sizes as noted on framing plans with CertainTeed 10" R38C kraftfaced fiberglass batt insulation, or equivalent, between rafters, vapor barrier laid down on ceiling strapping. Exterior face of roof trusses shall have 3/4" CDX plywood, 15# roofing felt and three tab asphalt roofing material with 30 year warranty. Supply 3" continuous soffit vent and ridge vent throughout, Shingle Vent II, or gable and wall vents as shown on drawings. Floors Framing -Sizes as noted on framing plans with CertainTeed 9 1/2" R30 kraftfaced fiberglass insulation, or equivalent, between joists, vapor barrier up. Subfloor to be 3/4" plywood glued & nailed down to joists. Ceilings shall be finished with GWB. Insulation Note: All floor joist spaces around the perimeter of the exterior wall shall be uniformly filled with insulation batts with continuous air seal to exterior. All rough openings for windows and doors and other spaces in conjunction with mechanical or electrical penetrations in the exterior wall or roof shall be packed with insulation and air tight. Roof trusses shall have 2 x 6 blocking above exterior wall plate to provide ventilation along the roof plane. s s ss SCOSCO S CO SCO S CO S CO 3'-0" x 3'-0" Access Pnl up to Attic