Loading...
HomeMy WebLinkAbout0140 BUCKSKIN PATH .� �. - �x „ . . , /� �.^ .� .- � ,. ., . ., � �. t _ , .Qoeeeo �X�o�r�cL S ai Z GQly December 29, 2015 ev /4p/NC p FpT, Town of Barnstable :Dec,3 ATTENTION. BULDING DEPARTMENT TOWN 0?��S 200 Main Street OPe Hyannis, MA 02601 A gNSTgeCF RE: 1.40 Buckskin Path, Centerville ° Permit No.: 201500480 Our Job No.: JB-026778 i NOTICE OF CANCELLATION This letter is to certify our proposal to install Solar(PV)at the above-referenced property has been moved into a cancellation status: SolarCity Corporation and Paul Nielsen will not be moving forward with the proposed installation at this time. We would greatly appreciate reimbursement for the permitting fees paid, but understand that the town will not refund any fees. If you have any questions or concerns, please don't hesitate to contact me. Thank you for your attention to this matter. Sincerely, ' Cheryl gruenstern, Cheryl Gruenstern « ; Permit Coordinator SolarCity Corporation cgruenstern@solarcity.com . Telephone: (508)640-5397 f t TOWN OF BARNSTABLE B � ' �� Ig 201500480 f • BARNSTABLE, Issue Date: 02/03/15 Permit 9 MASS $Ar 16 3�a�� Applicant: SOLARCITY CORPORATION Permit Number: B 20150217 Proposed Use: SINGLE FAMILY HOME Expiration Date: 08/03/15 Location 140 BUCKSKIN PATH Zoning District RC Permit Type: RES SOLAR PANELS Map Parcel 170069 Permit Fee$ 112.20 Contractor SOLARCITY CORPORATION Village CENTERVILLE App Fee$ 50.00 License Num 98660 Est Construction Cost$ 22,000 Remarks APPROVED PLANS MUST BE RETAINED ON JOB AND INSTALL SOLAR PANELS ON ROOF OF EXISTING HOUSE THIS CARD MUST BE KEPT POSTED UNTIL FINAL 8.925KW,35 PANELS INSPECTION HAS BEEN MADE. WHERE A CERTIFICATE OF OCCUPANCY IS REQUIRED,SUCH Owner on Record: NIELSEN,PAUL A&DIANE M BUILDING SHALL NOT BE OCCUPIED UNTIL A FINAL Address: 140 BUCKSKIN PATH INSPECTION HAS BEEN MADE. CENTERVILLE,MA 02632 Application Entered by: JL Building Permit Issued By: THIS PERMIT CONVEY S,NO RIGHT TO OCCUPY.AINYSTREET,ALLEY OR SIDEWALK OR ANY PART THEREOF,EITHER ORARILY WERWNTJY. ENCROACHMENTS ON.PUBLIC PROPERTY,NO,-. ,SPECIFICALLY PERMITTED UNDER THE'BUILDING CODE;MUST BE APPROVED BY THE JURISDICTION:` STREET OR'ALLEY'GRADES AS WELLAS:DEPTH AND LOCATION OF PUBLIC SEWERS MAYBE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS"THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM THE CONDITIONS OF ANY APPLICABLE SUBDIVISION .�c.4 RESTRICTIONS t MINIMUM OF FIVE CALL INSPECTIONS REQUIRED FOR ALL CONSTRUCTION WORK: 1.FOUNDATION OR FOOTINGS. 2.SHEATHING INSPECTION 3.ALL FIREPLACES MUST BE INSPECTED AT THE THROAT LEVEL BEFORE FIRST FLUE LINING IS INSTALLED. 4.WIRING&PLUMBING INSPECTIONS TO BE COMPLETED PRIOR TO FRAME INSPECTION. 5.PRIOR TO COVERING STRUCTURAL MEMBERS(FRAME INSPECTION). 6.INSULATION. 7.FINAL INSPECTION BEFORE OCCUPANCY. WHERE APPLICABLE,SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL,PLUMBING AND MECHANICAL INSTALLATIONS. WORK SHALL NOT PROCEED UNTIL THE INSPECTOR HAS APPROVED THE VARIOUS STAGES OF CONSTRUCTION. PERMIT WILL BECOME NULL AND VOID IF CONSTRUCTION WORK IS NOT STARTED WITHIN SIX MONTHS OF DATE.THE PERMIT IS ISSUED AS NOTED ABOVE. PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO GUARANTY FUND(as set forth in MGL c.142A). 0 r11 ww� � , '4111%1"Wo BUILDING INSPECTION APPROVALS PLUMBING INSPECTION APPROVALS ELECTRICAL INSPECTION APPROVALS 1 1 1 2 2 2 3 1 Heating Inspection Approvals Engineering Dept Fire Dept 2 Board of Health TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION Map:. 170 Parcel Application # Health Division Date Issued 2-h/IS Conservation Division Application Fee Planning Dept. Permit Fee (A;- Date Definitive Plan Approved by Planning Board Historic - OKH _ Preservation/ Hyannis .� Project Street Address l y� xynt 44 Aa Village Ce?�r✓ le Owner /°avl /�GSe/e Address 6_40 &Xejs9r r! 9? Telephone 00 F' 77/- o232.3 Permit Request lnsWl 3glat"ei6r c, 4&ieA CV7 D CG S ha.& thecA Square feet: 1 st floor: existing —proposed 2nd floor: existing proposed Total new Zoning District Mc Flood Plain Groundwater Overlay Project Valuation 9QW. Construction Type1/29A Lot Size " Grandfathered: ❑Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family i ' Two Family ❑ Multi-Family (# units)Ahj T n Age of Existing Structure 7 7 WS, Historic House: ❑Yes B No On Old Kings Highway: ❑Yes ❑ No Basement Type: ❑ Full ❑ Crawl ❑Walkout ❑ Other —� �. Basement Finished Area (sq.ft.) Basement Unfinished Area (s .ft) cn Number of Baths: Full: existing new Half: existing x1Dw 5 Number of Bedrooms: existing— new Total Room Count (not including baths): existing new First Floor Room Count —' Heat Type and Fuel: ❑ Gas ❑ Oil ❑ Electric ❑ Other Central Air: ❑Yes ❑ No Fireplaces: Existing —New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new size_Pool: ❑ existing ❑ new size _ Barn: ❑ existing ❑ new size_ Attached garage: ❑ existing ❑ new size _Shed: ❑ existing ❑ new size _ Other: �— Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes ❑ No If yes, site plan review# Current Use nf 14l Proposed Use/0 644dP� APPLICANT INFORMATION (BUILDER OR HOMEOWNER) Name1,501anz an a, Telephone Number Sl/6 741k ' Address 400 co/-00-4 par, License # CS 107�y10-� /4617&pre_ Home Improvement Contractor# /6S�ia2 Email_'Ok&y!''l Worker's Compensation # ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BETAKEN TOG? G[ S,6- SO'kirr'l. / � �e �ihd a � SIGNATURE DATE FOR OFFICIAL USE ONLY APPLICATION# r DATE,ISSUED MAP4 PARCEL NO. r ' ADDRESS VILLAGE Y OWNER DATE OF INSPECTION: FOUNDATION FRAME r INSULATION FIREPLACE ay ELECTRICAL: ROUGH FINAL PLUMBING: ROUGH FINAL- ; GAS: ROUGH FINAL FINAL BUILDING r DATE,-.CLOSED OUT " ASSOCIATION PLAN NO. ` ` DocuSign Envelope ID:6AE5C834-8ECE-4529-A6D6-29F76E7C287D NM�� ,-osolarClt y 3055 Clearview Way,San Mateo,CA 94402 SolarLease T (888)SOL-CITY F(650)560-6460 SOLARCITY.COM SUMMARY Date: 1/12/2015 Customer Name and Address` Customer Name Installation Location Contractor License Paul Nielsen 140 Buckskin Path MA HIC 168572/EL-1136MR 140 Buckskin Path Barnstable, MA 02632 Barnstable, MA 02632 Estimated Solar Energy Production First Year Annual Production: p 7,066 kWh Initial Term Total Production: 134,811 kWh Payment Terms Amount Due at Contract Signing: $0 Amount Due when Installation Begins: _ $0.00 Amount Due following Bldg.Inspection: $0.00 Estimated Price per kWh First Year: $0.1504 Annual Increase: 0.00% First Year Monthly SolarCity Bill: r $88.58 " Lease Term 20 Years ' I SolarCity's Promises to You: Your Prepayment and Transfer Choices During the • SolarCity will insure,maintain,and repair the System (including the Term: inverter)at no additional cost to you as specified,in the`agreement. It you move,you may transfer this agreement to the purchaser of your • SolarCity will provide 24/7 web-enabled monitoring at no additional Home,as specified in the agreement. cost to you,as specified in the agreement. If you move,you may prepay the remaining payments(if any)at a • SolarCity will provide a money-back production guarantee,as discount. specified in the agreement. • SolarCity will warranty your roof against leaks and restore your roof Your Choices at the End of the Initial Term: at the end of the agreement as specified in the agreement. • The pricing in this Lease is valid for 30 days after 1/12/2015. If you • SolarCity will remove the System at no additional cost to you. don't sign this Lease and return it to us on or prior to 30 days after • You can upgrade to a new System with the latest solar technology 1/12/2015,SolarCity reserves the right to reject this Lease unless under a new contract. you agree to our then current pricing. • You may renew your agreement for up to ten(10)years in two(2) • We are confident that we deliver excellent value and customer five(5)year increments. service.AS A RESULT,YOU ARE FREE TO CANCEL ANYTIME AT NO • Otherwise,the agreement will automatically renew for an additional CHARGE PRIOR TO CONSTRUCTION ON YOUR HOME. one(1)year term at 10%less than the then-current average rate charged by your local utility. SolarLease,version 6.7.0,November 11th,2014 500418 ❑� ❑� -� SAPC/SEFA Compliant Document Generated on 1/12/2015 DocuSign Envelope ID:6AE5C834-8ECE-4529-A6D6-29F76E7C287D 22. PUBLICITY I have read this Lease and the Exhibits in their entirety and acknowledge that I have received a complete copy of this SolarCity will not publicly use or display any images of the System Lease. unless you initial the space below. If you•initial the space below,you give SolarCity permission to take pictures of the System as installed on your Home to show to other customers or display on our website. Customer's Name: Paul Nielsen o�pwner's Initials oowsis�a ny: Signature: =�au�;IUt;�Stln� 3D2CDA756781474... 23. NOTICE OF RIGHT TO CANCEL Date: I/i 21203 5 YOU MAY CANCEL THIS LEASE AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS LEASE. SEE EXHIBIT 1, Customer's Name: THE ATTACHED NOTICE OF CANCELLATION FORM, FOR AN EXPLANATION OF THIS RIGHT. Signature: 24. ADDITIONAL RIGHTS TO CANCEL Date: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS LEASE UNDER SECTIONS 6 AND 23, YOU MAY ALSO CANCEL THIS LEASE AT NO COST AVAa \° `SolarCity. AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. SolarLease j 25. Pricing SOLARCITY APPROVED The pricing in this Lease is valid for 30 days after 1/12/2015. If you don't sign this Lease and return it to us on or prior to 30 days after 1/12/2015,SolarCity reserves the right to reject this Lease unless you agree to our then current pricing. Signature: LYNDON RIVE,CEO SolarLease '°SolarCity. Date: 1/12/2015 0 SolarLease,version 6.7.0,November 11th,2014 500418 SAPC/SEFA Compliant Office of Consumer Affairs and Business Regulation -g W7 10 Park Plaza - Suite 5170 - Boston, Massachusetts 02116. Home Improvement Contractor Registration ' Registration: 168572 Type: Supplement Card SOLARCITY CORPORATION Expiration: 3/e/2015 CRAIG ELLS 24 ST. MARTIN STREET BLD 2 UNIT 11. ' — -- — - ---- MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. sCA i r, ?014.0511 � Address 71 Renewal (—I Employment LI Lost Card /lruitvw?olll? f llll.�I: z-Office of Consuniei Affairs&Business Regulation License or registration valid for individul use only ' before the expiration date. If found return to: IMPROVEMENT CONTRACTOR p Registration: 168572 Typ( Office of Consumer Affairs and Business Regulation 10 Park Plaza-Suite 5170 r-'`` Expiration: 3/8/2015 Supplement•:ard Boston,MA 02116 SOLARCITY CORPORATION CRAIG ELLS 24 ST.MARTIN STREET BLD 2UNI I6 ALBOROUGH,MA 01752 Undersecretary Not v lid without signature t Massachusetts .Department of Pt:btic SIfeti Board of Building Regulations and St.. trds C'uFiiitra49un �911fi,'a•1lifrl License. CS-107663 CRAIG ELLS % . 206 BAKER STREET;I i Keene NH 03431 C+rrr�n+rs�ir�ric r 08/29/2017 r ��� f-5o1mmV101n1Wea4A �' C���a l r'XC��GCfIG�r� , J. Office of Consumer Affairs and Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card Expiration: 3/8/2015 . SOLARCITY CORPORATION NILE MILLER 24 ST. MARTIN STREET BLD 2 UNIT 11` MARLBOROUGH, MA 01752 Update Address and return card.Mark reason for change. sca i Co zoM osn 0 Address ❑ Renewal El Employment :_1 Lost Card r✓lec �r-7ii iirtzoureu�/�r�rl�X�.'cre�rt�r/�' - . ffice of Consumer Affairs&Business Regulation License or registration valid for individul use only IF ~ ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation �y egistration: 168572 Type. 10 Park Plaza-Suite 5170 Expiration:P� 3/8/2015 Supplement i:-ard Boston,MA 02116• SOLARCITY CORPORATION NILE MILLER 24 ST MARTIN STREET BLD 2UNI i51AF'tLBOROUGH,MA 01752 Undersecretary Not valid without signature R The Commonwealth of Massachusetts Department oflndustrialAccidents h Ogice of Investigations 1 Congress Street,Suite 100 Boston,MA 02114-2017 f www massgov/din' t Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organimtion/Individual): SolarCity Corporation • t. Address:3055 Clearview Way City/State/Zip:San Mateo, CA 94402 Phone#:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): 1.0 I am a employer with 7000 4. ❑ I am.a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7= ❑Remodeling ship and have no employees t` These sub-contractors have g, ❑Demolition workingfor me in an capacity. employees and have workers' t Y P ty z 9. ❑Building addition [No workers' comp.'insurance comp. insurance. required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I LE]Plumbing repairs or additions t� myself. [No workers' comp. - right of exemption per MGL 12.❑Roof repairs P. insurance required.] t _ c, 152,§1(4),and we have no Solar Panels employees. [No workers' 13. Other comp:insurance required.] [. *Any applicant that checks box 91 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. Iam an employer that isproviding workers'compensation insurancefor my employees Below is thepolicy andjob site information. , Insurance Company Name:Liberty Mutual Insurance Company Policy#or Self-ins.Lic. #:WA7-66D-066265-024 Expiration Date:09/01/2015 Job Site Address: l 1J —&Ct 5tff1^ AdLX� City/State/Zip: gAr/151 '/ Gt �•�0, Attach a copy of the workers' compensations policy declaration page(showing the policy number and expiration'date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be*advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Ido hereby certify under the pains and penalties ofperjury that the information provided above is true and correct i Si w,,L87?_ Date: 7818167489 n - s Phone#: - Offwial use only. Do not write in this area,to be completed by city or town official. City or Town. Pcrmit/License# Issuing Authority(circle one):. 1.Board of Health 2:Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector "} 6.Other Contact Person-, Phone#• h .I f , �'�V CERTIFICATE OF LIABILITY INSURANCE °0800tl°D"""'/' 08@9/2014" THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to ' the terns and conditions of the policy,certain policies may require an endorsement A statement.on this certificate does not confer rights to the I certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK 8 INSURANCE SERVICES PHONE FAX 345 CAUFORNIA STREET,SUITE 1300 o EA): A/C No): r CALIFORNIA LICENSE NO.0437153 -MAIL SAN FRANCISCO,CA 94104 R= S AFFORDINGCOVERAGE _—_--_ „--- --._. . -__NAIC/ .-_ 9MI-STND-GAWUE-14-15 INSURERA:Liberty Mutual Fire Insurance Company 16536 INSURED Ph(650)963-5100 INSURER 8:Libeq Insurance Corporation 424N SolarCity Corporation INSURER C:NIA NIA 3055CWMe ay INSURER D: Sani ateo,CA 94402 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002440289V REVISION NUMBER:4 r THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS j CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, I EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LIMITS 1 - LTR POLICY NUMBER MMIDD M A GENERAL LIABILITY TB2-661-056265-014 09/01/2014 09/01/2015 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY - DAMAGE TO RENTED PREMISES Ea ocarrenos $ 100,000 CLAIMS-MADE a OCCUR MED EXP(Any one person) $ 10,000 - PERSONAL&ADV INJURY $ 1,000,000 . GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $ 200,000 X POLICY X PR4ECT LOC Dedod ble $ 25,000 A AUTOMOBILE LIABILITY AS2-661-1=65044 09/01/2014 09M/2015 COMBINED SINGLE LIMIT Ea aocsdent ------__..'I'm. .._- X ANYAUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED _ BODILY INJURY(Per accident) $ AUTOS AUTOS X NON-OHIRED AUTOS rX AUTOS (Per dent)DAMAGE $ i X Phys.Damage COMP/COL DED: S $1,000/$1,000 UNIBRELLA LIAR OCCUR EACH OCCURRENCE $ EXCESS LIAB H CLAIMS-MADE AGGREGATE $ DED 1 I RETENTION$ $ B WORKERS COMPENSATION �WA7-06D-0662WM4 09101/1014 091DW015 X I WC STATU- I OTH- AND EMPLOYERS'LIABILITY B ANY PROPRIETOR/PARTNER/EXECU PJE Y/N WC7 661-066265034(Wq 09/01/2014 09101/2015 1,000,000 OFFICER/MEMBER EXCLUDED? NIA I EL EACH ACCIDENT $ B (Mandatory in NH) !'WC DEDUCTIBLE:$350,OW EL DISEASE-EA EMPLOYEE S 1,000,000 H yes,descrbe under P I DESCRIPTION OF OPERATIONS below •,L - EC DISEASE-POLICY LIMB $ 1,000,000 DESCRIPTION OF OPEM71ONS/LOCATIONS/VEHICLES_ (Attach ACORD 101,Additional Reararrrs Schedule,if more space Is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SolarCity Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 ClearAaw Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo;CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. f AUTHORIZED REPRESENTATIVE of Marsh Risk S Insurance Services Charles Marmolejo ©1938-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD ��• Version#42.2 RU SolarCit / r 1 f q Afao�8W®. IWHiTE,; January 15, 2015 '. 4y STRUCTURALNG gn Project/Job #026778 , 373i9 RE: CERTIFICATION LETTER Project: Nielsen Residence NAL 140 Buckskin Path _ Barnstable, MA 02632 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes= MA Res. Code, 8th Edition,ASCE 7-05, and 2005 NDS - Risk Category = II -Wind Speed = 110 mph, Exposure Category C -Ground Snow Load = 30 psf -_MP1: Roof DL= 11.5 psf, Roof.LL/SL= 23.1 psf(Non-PV Areas), Roof LL/SL= 15.6 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.19069 < 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV'assembly have, been reviewed. After this review it has been determined that the existing structure requires structural upgrades as detailed in the plan set to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural,roof framing including the specified upgrades and the new attachments that directly support the gravity loading and wind uplift loading from.PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code; 8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, 3 , Andrew White, P.E. Digitally signed by Andrew White ' Structural Engineer Date:2015.01.15 10:58:55-05'00' Main: 888.765.2489,x2377 email: awhite@solarcity.com 3055 Clearview Way San Mateo,CA 94402 T(650)638-1028-(888)SOL-CITY F(650)638-1029 solarcity.com AZROO243771,CA OSLB 868104,OO EC 8041.CTKO0032778.DC HIC.71101486,DC HIS 71101488,HI CT-20770.MA HIO 168572.MD MHICIM948,NJ 13VH00160800.. OR CCS'100498,PA 077343.TX TD6R 27006,WA GCL:SOLAA0'919g7.O 2013 SolarCity„Ali rights rd"mod. 4 01.15.2015 SolarCityPV System Structural Version#42.2 Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Nielsen Residence AHJ: Barnstable Job Number: 026778 Building Code: MA Res. Code, 8th Edition Customer Name: Nielsen, Paul Based On: IRC 2009/ IBC 2009 Address: 140 Buckskin Path ASCE Code: ASCE 7-05 City/State: Barnstable, MA Risk Cateqory: II Zip Code 02632 Upgrades Req'd? Yes Latitude/ Longitude: 41.662615 -70.361597 Stamp Req'd? Yes SC Office: South Shore PV Designer:; Pete Aldermeshian Calculations:I Justin Arbuckle EOR: Andrew White, P.E. Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.19069 < 0.4g and Seismic Design Category (SDQ = B < D 1 2-MILE VICINITY MAP r 61 -1C�MassGIS*, Commonwealth of Massachusetts • - - Agency 140 Buckskin Path, Barnstable, MA 02632 Latitude: 41.662615, Longitude: -70.361597, Exposure Category: C LOAD ITEMIZATION - MP1 PV S stem Load PV Module Weight(psf) 2.5 psf -. e- � ,f Hardware Assembl"Wei ht sf)— 0.5 lasf, r. PV System Weight 3.0 ncf Roof Dead Load Material Load' Roof Category Description MPl Existmg.Roofing Material f Comp Roof - -- (2 Layers) 5.0 psf. Re-Roof No - Underlayment` -- - -- Roofing Paper 0.5,psf _- Plywood Sheathing Yes 1.5 psf Board Sheathings None .�� - - -- Rafter Size and Spacing 3 x 6 @ 16 in.O.C. 3.4 psf Vaulted,Ceilmg� 4 Miscellaneous Miscellaneous Items 1.1 psf Total Roof Dead Load 11.5 Psf MPi 11.5 Psf Reduced Roof LL Non-PV Areas Value ASCE 7-05 Roof Live Load Low 20.0 psf Table 4-1 Member Tributa Area__,, _ ~� Ate � <'200 sf Roof Slope 7/112 ta Triburction��_�" - ry Aea,Redu - - - Ri' .v> . 1 �..Section_49 Sloped Roof Reduction R2 0.85_ Section 4.9 Reduced Roof Live Load - "' Lr L,= L.(Rl)IR2) Equation 42 r Reduced Roof Live Load Lr 17 psf(MPI) 17.0 ncf Reduced Ground/Roof Live/Snow Loads Code Ground Snow Load p9 30.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? tr Yes Effective Roof Slope 300 I Horiz._Distance_from Eve to_Ridge° W_ 16 7 ft Snow Importance Factor IS 1.0 Table 1.5-2 Snow,Exposure;Factor 4 CQ Partially Exposed Table 74 1.0 Snow Thermal Factor Ct Structures kept just above freezing Table 7-3 _.. -.- Minimum Flat Roof Snow Load(w'— ' � Pf-min 23.1 psf 7 3 4&7 10' Rain on-Snow Surcharge) •- - - Flat Roof Snow Load Pf pf= 0.7(C.) (CJ (I) pg; pf>_-pf-min Eq: 7.3-1 23.1 psf 77% ASCE Design Sloped Roo Snow Load Over Surrounding Roo Surface Condition of Surrounding Roof CS_roof All Other Surfaces 10 Figure 7-2 Design Roof Snow Load Over Ps-roof= (Cs-root)Pf ASCE Eq: 7.4-1 Surrounding Roof Ps-roof 23.1 psf 77% ASCE Design Sloped Roof Snow load Over PV Modules Surface Condition of PV Modules CS_ Unobstructed Slippery Surfaces 0.7 Figure 7-2 Design Snow Load Over PV PS-PV= (CS-PV)Pf ASCE Eq: 7.4-1 Modules PS P" 15.5 Psf 52% i COMPANY PROJECT A WoodWorksOD SOF"VAINMR WOOD"SFGN- Jan. 15, 2015 09:57 MP1.wwb Design Check Calculation Sheet WoodWorks Sizer 10:1 Loads: Load Type Distribution Pat- Location_ [ft] Magnitude Unit tern Start End Start . End DL Dead Full Area No 11.50 (16.0) * psf PV LOAD Dead Partial Area No 1.17 13.08 3.00 (16.0) * psf SNOW LOAD Snow Full Area No 23:10 (16.0) * psf LIVE IRoof constr. Full Area No 17.00 (16.0) * psf *Tributary Width (in) Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 0' 1'-2" 14'-7'. Unfactored: Dead 171 145 Snow 244 209 Roof Live 179 154 Factored: Total 415 353 Bearing: F'theta 518 518 Capacity Joist 6023 2331 Supports 5020 Anal/Des Joist 0.07 0.15 Support 0.08 - Load comb #3 #3 Length 3.50 1.50 Min req'd 0.50* 0.50* Cb 1.11 1.00 Cb min 1.75 1.00 Cb support 1.13 - Fcp sup 425, - *Minimum bearing length setting used: 1/2"for end supports Bearing for wall supports is perpendicular-to-grain bearing on top plate. No stud design included. MP1 Lumber n-ply, S-P-F, No.1/No.2, 2x6, 2-ply (3"x5-1/2") Supports: 1 -Lumber Stud Wall, S-P-F Stud; 2.-Hanger; Roof joist spaced at 16.0"c/c; Total length: 17'-3.3'; Pitch: 7/12; Lateral support: top=full, bottom= at supports; Repetitive factor: applied where permitted (refer to online.help); `1 WOodWorkS® Slzer SOFTWARE FOR WOOD DESIGN MP1:wwb WoodWorks®Sizer 10.1 Page 2 Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012 : Criterion Analysis Value Design Value Analysis/Design . Shear fv = 26 Fv' = 155 fv/Fv' = 0.17 Bending(+) fb = 934 Fb' = 1504 fb/Fb' = 0.62 Bending(-) fb = 26 Fb' = 1504 fb/Fb' = 0.02 Deflection: Interior Live 0.51 = L/367 1.04 = L/180 F 0.49 Total 0.88 = L/212 1.55 = L/120 0.56 Cantil. Live. -0.14 = L/116 0.18 = L/90 0.77 Total -0.24 = L/67 1 0.27 = L/6.0 0.89 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF' Cfu Cr Cfrt Ci Cn LC# Fv' 135 1.15 1.00 . 1.00 - - - - 1.00 1.00 1.00 3. Fb'+ 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00 3 Fb' - 875 1.15 1.00 1.00 1.000 1.300 1.00 1.15 1.00 1.00' - 3 Fcp' 425 - 1.00 1.00 - - - - 1.00 1.00 - E' , 1.4 million 1.00 1.00 - - - - 1.00 1.00 ' - 3 CRITICAL LOAD COMBINATIONS: Shear LC #3 = D+S, V = 310, V design = 286 lbs Bending(+) : LC #3 = D+S, M = 1178 lbs-ft Bending(-) : LC #3 = D+S, M = 33 lbs-ft Deflection: LC #3 = D+S (live) LC #3 = D+S (total) , D=dead L=construction S=snow w=wind I=impact Lr=roof constr. Lc=concentrated All LC's are listed in the Analysis output Load combinations: ASCE, 7-10 / IBC 2012 CALCULATIONS: - - Deflection: EI = 29e06 lb-in2/ply "Live" deflection = Deflection from all non-dead loads (live, wind, snow...) Total Deflection = 1.00 (Dead Load Deflection) + Live Load Deflection. Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Design Notes: 1.WoodWorks analysis and design are in accordance with the ICC International Building Code (IBC.2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. ; 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4:1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 6. The critical deflection value has been determined using maximum back-span deflection. Cantilever deflections do not govern design. CA LCULATION_OFDESIGN WIND LOADS=-MP1 Mounting Plane Information Roofing Material Comp Roof _ _1 -- : PV_System Type SoarCity SleekMountT" a. - Spanning Vents e� No Standoff Attachment Hardware Comp Mount Type C Roof Slope 300 Rafter$ ac_i_ng 16"O.C. " --- Framing Type Direction Y-Y Rafters Purlin Spacings X-X Purlins Only_ NA m • -- - - — - Tile Reveal Tile Roofs Only NA Tile Attachment S_ystem Tile Roofs Only _ __ _ �NAw Standin Searn/Trap Spiacinq SM Seam Only NA Wind Design Criteria Wind_ Design Code _Y ASCE 7-05 nd Design;Method Wi -"� Partial Full Enclosed Method N/., Basic Wind Speed V. 110 mph Fig. 6-1 Exposure C_ate o "^ C °Section 6:5.6`3 " g_rY Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height' h 15 ft -v, 4F Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor- _Krt 1.00 Section'6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor` I To T ATable 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(VA 2)(I) Equation 6-15 22.4 psf Wind Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ext."Pressure Coefficient Down GC Down 0.88 s Fig.'6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U -21.3 psf Wind Pressure Down 19.6 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing___ Landscape (All39" Max Allowable;Cantilever _ _Landscape „ 24 NAB Standoff Configuration Landscape Staggered Max StandoffTributary_Area „ �_ Trib_ __ _ `17 sf" PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff, v T-actual � -3-4f Ibs x . Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/CapacityDCR 68.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Alo able Cantilever" -- - _____Portrait s 4 19" Standoff Configuration Portrait Staggered Max Standoff�Tributary,_Area Trib �. 22 sf PV Assembly Dead Load W-PV 3 psf Net WindUplift at Standoff T-actual -426 lbs Uplift Capacity of Standoff T-allow 500 Ibs . Standoff Demand Ca aci - DCR _85.3% Town of Barnstable Q W (IR 8ARNST Regulatory Services Thomas F.Geller,Director 2006 OCT 19 AM 11: 14, Building Division Tom Perry,Building Commissioner. 200 Main Street, Hyannis,MA 02601 ��(. ( www.town.barnstable.ma.us Office: 50&862-4038 Fax: 508-790-6230 PERMIT# o2a®6 ,3VA, - L FEE: $ t SHED REGISTRATION 120 square feet or,less Location of shed(address) Village 71,v L �q4UC Sod} �771--A39 3 Property owner's name Telephone number . � f ! Size of Shed Map/parcel# ° 0cr03C2 Signature Date Hyannis Main Street Waterfront Historic District? ao Old King's Highway Historic District Commission jurisdiction? No Conservation Commission(signature is required) #0 PLEASE NOTE: IF YOU ARE WITHIN THE JURISDICTION OF ANY OF THE '® ABOVE COMMISSIONS,THERE MAY BE A REVIEW PROCESS AND APPLICATION FEE. PLEASE SEE THE APPROPRIATE COMMISSION FOR DETAILS. THIS FORM MUST BE ACCOMPANIED BY A PLOT PLAN Q-forms-shedreg REV:121901 p d /V S... .... ....... M.'. -.. x it 3 _. _* G .4o7-z$ W. fm 4 L h �. . y r -- s "- 1��� o - /37. 9s' a : 4 1oT ZS CERTIFIED PLOT. PLAN . — a /rf?B , xr LOCATION �PA ,�'&w16Rt!nI�►i+ss: .._/VoTe� Ti`fr P1Z: r�i�2TX` ,OYES /V.c�'�i4-tC• Gt,�iTl,['/a� A'-, �� . ^NIGH f��4 �✓ caoD Zo.v�: Lowe C::� as SCALE � —30' DATE .7�`6/�� :,.... Qo !FC ;/s'1r+P jlc/�S�D . A-wGvsT/q /98'fd3y e PLAN REFERE NC EP4 _ 6o"-Nov, /970:CllAV S N, " RCZ Eh/GAN1t SL+Rf/�+fQYsS MA S E�'B+4/s�sT. , r riris t' FL' Bic Z 44K/V 67`. 41,10 . . . _�CERTIFY THAT THE CM(417A -0"140W^4� SHOWN.ON THIS PLAN IS LACATED ON THE.;BROUNC • f . AS SHOMIN HEREAIt DATE . ,/ PETITIONER Nt�l.���v' �, r dN.yalQA?OYj?/j hl/t 5S RE6. PROFES3�ONAt:.LANO:SURVEYOR f. a ,.tip R T"E?°�° TOWN OF BARNSTABLE BAHBSTADLE, i "6 9 am BUILDING INSPECTOR ay a APPLICATION FOR PERMIT TO ... ... ......................................................................................... TYPE OF CONSTRUCTION .......... - °:"se' "....................................................................................... A!.. .... ......... ...................19.7.0 TO THE INSPECTOR OF BUILDINGS: , r The undersigned hereby applies for a permit according to the following information: 49 Location ....... ............. . .. : �" ..........14* :`. /. .f P '... .................................... ..... .... Proposed Use / /7u r- .!' ... ..................... Zoning District ..................0................. ................ ........Fire District ........ .. .... ... ... d:......... r Nameof Owner . :... ........................................Address ........ ............................................... Nameof Builder ....................................................................Address .......................:............................................................ Nameof Architect ........./........................................................Address .................................................................................... Numberof Roo s ........"......................................................Foundation ... ....................................... Exterior . ... ... .. ......... ...........................................................Roofing ... �..:...:......:..,.� ...... ..... ... ." ................. Floors PP ..'' .....................................Interior .. . . HeatingF ............................................Plumbing ...�... .... ..............� ............................................. Fireplace ..................................ApproxirlatP Cost .... .TJ. .............................................. 4� .Difinitive Plan Approved by Planning Board ________________________________19________. � s Diagram of Lot and Building with Dimensions IR I hereby agree to conform to all the Rules and Regulations of the Town of Barnstable regard the above construction. Name ........................ .. c�........................... Small, Alan -bit13557 /Dto nCe�"t 0 ry single family dwelling --------------------------- Locohon'�7�� Jec2ok- Centerville } .------.~.---.-------.------ Alan E. Small � Owner —.—_—.-----------------. Type of Construction �^=~~ .......................................... —.----.---...---.-----.--.----.. � Plot ............................ Lot --..��. ---- ^ ' / Permit �ron�o6 2? lQ �� � | � —..���:'=��..``=--- . v ,V Date of Inspection ------------l9 v Dote Completed —..�.������.°..^.=—.]g ^^� | --� � PERMIT REFUSED -----.._----..---.--_---- 19 \ .---...----.----..—.--...—..---..... ~& . —._—.—,—..----.—.,.--.--..—..~....—,_ ~* � � ^ ---------'---'---------~-----' = � --'—'—'----'-'---'—'—'----''''------ / Approved ................................................ 19 / ` ^ -------'-------,.—....'.—...--.—.— . . -------'---'-'-----'---^^^~^'~^- " \ 1 ' | \ ` ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. a (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, 4. FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE r GALV GALVANIZED HAZARDS PER ART. 690.17. C) GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY g ' HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL =' Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PVT COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached v _ GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Barnstable REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) CON J B-0 2 6 7 7 8 00 PR°°SE OWNER. DESCRIPTION:CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �\\!+CONTAINED SHALL NOT USED FOR THE NIELSEN, PAUL NIELSEN RESIDENCE Pete Aldermeshian ��� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �a3 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 140 BUCKSKIN PATH 8.925 KW PV ARRAY ,`S®larCr PART TO OTHERS OUTSIDE THE RECIPIENT'S MoputEs BARNSTABLE MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St Martin Drive,Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (35) TRINA SOLAR # TSM-255PA05.18 gl�: V pp Mar@oraive, MA ing Z SOLARg1Y EOUIPMENT, WITHOUT THE WRITTEN PAGENAME T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARgTY INC. INVERITR. " SOLAREDGE # SE760OA—USOOOSNR2 (508) 771-2393 COVER SHEET PV 1 1/15/2015 (B66)-SOL—CITY(765-2469) www.eola«Ity.com PITCH`. 30 ARRAY PITCH:30 MP1 AZIMUTH:90 ARRAY AZIMUTH:90 MATERIAL:Comp Shingle STORY: 1 Story 140 Buckskin Path Front Of House (E) DRIVEWAY .A AC Ott 1 Inv ,' :1 LEGEND ' -J (E) UTILITY METER & WARNING LABEL 9 9Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS O DISTRIBUTION PANEL & LABELS l AraoREr D_ R\ vriitT� � LOAD CENTER & WARNING LABELS sTnucruRAL No 47310 O DEDICATED PV SYSTEM METER 12 . NA4 p STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR Dig Illy Sig a by rew --- CONDUIT RUN ON INTERIOR White GATE/FENCE Date:2015.01.15 10:57:53-05'00' HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED STAMPED & SIGNED L FOR STRUCTURAL ONLY SITE PLAN Scale: 1/8" = 1' �, Z 0 1' 8' 16' m CONFIDENTIAL-'THE INFORMATION HEREIN JOB NUMBER: I Q PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE v B—O CJ O O ���� a NIELSEN, PAUL NIELSEN RESIDENCE Pete Aldermeshian `i;�SolarC�ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �..� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 140 BUCKSKIN PATH 8.925 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES* BARNSTABLE MA 02632 ORGANIZATION, EXCEPT IN CONNECTION WITH ' THE SALE AND USE OF THE RESPECTIVE (35) TRINA SOLAR # TSM'.255PA05.18 24 St.Martin OuMarlbororigh BA 01 2,unit tt 752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE T: (650)638-11028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE760OA—USOOOSNR2 (508) 771-2393 SITE PLAN PV 2 1/15/2015 (888)-SOL-CITY(765-2489) www.Saarcity.con (N) SIMPSON A34 CLIP W/ (8) 8D NAILS qF 6 ENDDISTANCE � � 16" O.C. TYP. (E) 2x6 RAFTER WIi1fl: i�m� s�Ul 2y4" 2x6 SPF#2 (N) IVc 17 — — . ,s —9't 4' MIN. XAt- s SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER S1 _ STAMPED &-SIGNED FOR STRUCTURAL ONLY , 4 D1 2x6 END FASTENER GROUPING 1' 13'-5„ Scale: (E) LBW . (:A SIDE VIEW OF MP1 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING ` UPGRADE NOTES: MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. LANDSCAPE 64" 24" sTAGGERE� 2. FASTEN (N) .SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2-PLY). OR 22458 PORTRAIT 48" 19" (IF 3—PLY) SDW SCREWS STAGGERED AT 1'6'' O.C. ALONG SPAN AS SPECIFIED, IF RAFTER 2x6 @ 16"OC ROOF AZI 90 PITCH 30 . STORIES: 1 WOOD SPLITTING IS-SEEN OR HEARD, PRE=DRILL WITH A " DRILL BIT. ARRAY AZI 90 PITCH 30 ALT. OPTION FOR FULL LENGTH MEMBERS ONLY— FASTEN (N) SIDE MEMBER TO C.I. 2x6 @16 OC I Comp Shingle (E) RAFTER W/ 10d (IF 2—PLY) OR 16d. FROM EACH'SIDE (IF 3-PLY) COMMON NAILS .AT 6" O.C. ALONG SPAN. •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED PV MODULE _ 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS (N) SISTER MEMBER TO BEAR LOCATE RAFTER, MARK HOLE ON PARALLEL CEILING JOIST ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT OR SUPPORT BELOW SIMPSON SDW 22458 SIMPSON SDW ZEP ARRAY SKIRT (6) HOLE. (E) RAFTER WOOD SCREWS 22300 WOOD (4) (2) SEAL PILOT HOLE WITH (N) SISTER MEMBERS SCREWS POLYURETHANE SEALANT. ZEP COMP MOUNT C 3 I RT F SHING. 3 O NSE LA .ZEP FLASHING C — • � 4 0 MIN. ` (N) SIMPSON-A34 CLIP J (E) COMP. SHINGLE (4) PLACE MOUNT. (E) WALL OR (1) SUPPORT,.BELOW D1 W/ (8) 8d NAILS (E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH (E) RIDGE BOARD OR SUPPORT BELOW 5/16" DIA STAINLESS (5) . SEALING WASHER- STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER WITH SEALING WASHER (6) ..BOLT & WASHERS. - , (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF TOP VIEW OF FULL LENGTH. LAPPED SISTER a e• 3 4 —1-0 S 1 / Scale: 1 1/2 = 1 t CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0 2 6 7 7 8 00 PREMISE OWNER: i DESCRIPTION: DEIGN: CONTAINED SHALL NOT BE USED FOR THE NIELSEN PAUL NIELSEN RESIDENCE Pete Aldermeshian BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ' - � llsolar-Lo"]t�/NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 140 BUCKSKIN PATH 8.925. KW PV ARRAY �r PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES: BARNSTABLE MA 02632 ORGANIZATION, EXCEPT IN CONNEC710N WITH 24 St. Martin.Drive, Buildin THE SALE AND USE OF THE RESPECTIVE (35) TRINA SOLAR # TSM-255PA05.18 g z unit 11 ., SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER: 508 771-2393 a - PV 3 1 15 2015. - T:.(sso)sae-1D2e F: (650)638-1029 SOLAREDGE SE760OA—USOOOSNR2 ( ) STRUCTURAL VIEWS / / (888)—SOL—CITY(765-2489) www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:Federal Pacific StabLok Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ## SE7600A-USOOOSNR LABEL: A -(35)TRINA SOLAR ### TSM-255PAO5.18 GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:43 957 093 Inverter; 76'0OW, 240V, 97.5%a w/�Unifed Disco and ZB, RGM, AFCI PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �N 125A MAIN SERVICE PANEL SolarCity N; 100A/2P MAIN CIRCUIT BREAKER Inverter(E) WIRING CUTLER-HAMMER Vel't2C 1 100A/2P Disconnect s SOLAREDGE 4 AF7 > DC+ SE760OA-USOOOSNR2 DC- MP 1: 1x18 (E) LOADS 6 ------------ -------- -- ECc---------------/---- L, zaov --------- , ~ I L2 Dc+ N DG I 3 2 - 40A/2P ---- GND ------------------------------------- -EGG/ --- aC+ DC+ - - - -- I A I - GEC N DG DG MP 1: 1x17 B ---,'- fqc ------------/�J�--. EGC_-_ _________tOConduit ------------ EGC --- -- I N I Kit; 3/4" EMT - _ _ -0)Conduit Kit; 3/4" PVC, Sch. 40 o EGC/GEC z l I I I � - GEC T- 1 TO 120/240V SINGLE PHASE I I I I UTILITY SERVICE I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Ground Rod; 5/8' x 8% Copper B (1)CUTLER-HAMMER #DC222URB ^ A (1)SolarCity p 4 STRING JUNCTION BOX D Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R A 2x2 STRMGS, UNFUSED, GROUNDED -(1)CUI R-�IAMMER #DG10ONB Ground//NNeutral Kit; 60-100A, General Duty(DG) PV 05)SOLAREDGE CP300-2NA4AZS PowerBox ptimizer, 30OW, H4, DC to DCi ZEP nd (1)AWG#6, Solid Bare Copper -(1)Ground Rod; 5/8" x 8'. Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE (1)AWG#8, THWN-2, Black (1)AWG #10, THWN-2, Black Voc*' =500 VDC Isc 15 ADC (2)AWG ##10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC (1)AWG#8, THWN-2, Red 3 `" (1)AWG y10, THWN-2, Red Vmp =350 VDC Imp=12.22 ADC 1 (1)AWG##6, Solid Bare Copper EGG Vmp =350 VDC Imp=12.94 ADC O (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC O' (1 AWG 10, THWN-2, Green EGC O . . . . . . .70 AWG #8,.TH !4-?,_Green . : EGC/GEC.-0)q*u.it.Kit;.3/4. .EMT. (I)AWG#10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG 10, PV WIRE, Black Voc* =500 VDC Isc'-15. . . DC A (A)PF(I(I)AWG#10, THWN-2, Red Vmp =350 VDC Imp=12.94 ADC O (1)AWG #{6, Solid Bare.Copper EGC Vmp =350 VDC Imp=12.22 ADC (1)AWG10, THWN-?,.Green;, EGG CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-0 2 6 7 7 8 0 0 �z.,,p NIELSEN, PAUL NIELSEN RESIDENCE Pete Aldermeshian ,solarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 140 BUCKSKIN PATH 8.925 KW PV ARRAY ��� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: BARNSTABLE, MA 02632 THE SALE AND USE OF THE RESPECTIVE (35) TRINA SOLAR # TSM-255PA05.18 24 st. Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Madborough,MA 01752 PERMISSION OF SOLARCITY INC. INVERTER. (/508 771-2393 PV 4 1 15 2015 888 (650)638-1028 F. (650)638-1029 SOLAREDGE SE760OA-USOOOSNR2 l ) THREE LINE DIAGRAM / / ( )-SOL-CITY(765-2489) www.solarcity.com Label Location: Label Location: Label Location: • e 0 e •o - o - (C)(CB) o IY�IYn7 (AC)(POI). (DC)`(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 •o o - o oM.. NEC 690.17.E ° -o • o o- •o•-° NEC 690.35(F) Label Location: o :o ° - o 0 0 TO BE USED WHEN (DC)(INV) o•° • - • -e • • • s INVERTER IS 01 'UNGROUNDED Per Code: D O . NEC 690.14.C.2 Label Location: Label Location: o (�� (POI) •o - (DC)(INV) uV Per Code: -o c�JPer Code: 12, ° ' NEC*690.64.B.7 - :� •° Dili NEC 690.53 •e o ee 0 ' 1 V • Label Location: - e (POI) Label Location: Per Code: o (DC)(CB) • •o 0 0 NEC 690.17.4; NEC 690.54 Per Code: - - e y. - - • •o 0 o NEC 690.17(4) Label Location: o �( (DC) (INV) Label Location: ' V_ Per Code: �n� �� (D)(POI) • TO ° ° NEC 690.5(C) e e e U uUIJV Per Code: o- -o ° •• ®:, • NEC 690.64.B.4 o • o- Label Location: Label Location: p (POI) m O O O�f ( jG ( ) (POI) AC Disconnect e . . . AC POI • n -o - o - Per.Code: (AC): D O Per Code: ' . o 0 0 NEC 690.64.B.4 (C):'Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit 'Label Location: (INV): Inverter With Integrated DC Disconnect r 4 (AC)(POI) • (LC): Load Center _. Per Code: (M): Utility Meter �►i0 •' n NEC 690.54 ) ` (POI): Point of Interconnection. x CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ®�®p® THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ^ �- SE ��q® IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC Label Set Dfat'��t T EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �� �OL93 Y SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o Next-Level PV Mounting Technology %''^SOIdfClty ®pSolar Next-Level PV Mounting Technology '�^SOIdfClty ®pSOlar Zep System Components for composition shingle roofs Up-roof _ I �» Intedook-- Grouts Zep (Key side shown) l.evelhg foot / i Y Zep Campatlbie PV Module _ ,t - - — `y—t• �S.S.' J y . ... - Zep Groove y Roof Attachment Array Skirt QOOMPgT, Description FA j aW PV mounting solution for composition shingle roofs - CGMPpt� Works with all Zep Compatible Modules o. ; • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond V� LISTED Comp Mount Interlock Leveling Foot Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 Designed for pitched roofs Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 t, • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.00m Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for _ each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. - responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 THE Vinamount MODULE TSM-PA05.18~ Mono Multi Solutions j DIMENSIONS OF PV MODULE r ELECTRICAL DATA @ STC " 1 unit:mm j Peak Power Watts-Pma (Wp) ��245 Y 250 .y -255 r" 260a i y � I 941 Power Output Tolerance P (%) 0-+3 THMount o Maximum Power VoltageV 299 30.3 1 30.5 30.6 'TM-a NRnN NAMEVLAIE o Maximum Power Current lmeb(A) 8.20 8.27 8.37 { 8.50 I - - i o t � Open Circuit Voltage-Voc(V) � 37.8- 1 _ 38.0 `- 38.1 ( 38.2 +ornLiwc NDLE +{Short Circuit Current-Isc(A) 8.75 8.79 a 8.88 9.00 • _ s 1 Module Efficiency qm(%) A_ -15.0 _ 15.3 ) 15.6+ ! -w 15.9 } - k d MODULE STC:Irradiance I OOO W/m-Cell Temperature 25-C.Air Mass AMI.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904 1 � c I ELECTRICAL DATA @ NOCT ...may,. ._ -. ( i� . Maximum Power PmA`W 4182 �186 1904 193 1 Pl I 6® CELL CMaximum Power Vonage-Vint(V) 27.6 � 28.0 28.1 28.3 f A Maximum Power Current Imer A - 6.59 6.65 6.74 6.84 H0 I MULTICRYSTALLINE MODULE " .3 GFOUNDWG NOLE A +' ) � ( r is-DnAw Nate A- Open Circuit Voltage(V)-Voc(V) ' 35.1 35.2 35.3 35.4 WITH TRINAMOUNT FRAME snorrCrauacu rent(A)Is �A) 7.07 7.10 7.v ' 7.27 PO NOCT Irradiance at 800 W/m,Ambient Temperature 20-C,Wind Speed I m/s. , 245-26OW PA05.18 , 812 SD _ Back View MECHANICAL DATA t I 7 Solar cells Mulflcrystalline 156=156 mm(6 inches) POWER OUTPUT RANGE - I Cell orientation 60 cells(6 N 10) _ Fast and simple to install through drop in mounting solution t Module dimensions t 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) b Weight 21.3 kg(47.0 Ibs) OI I Glass ( 3.2 min(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY Backsheef wane T A-A i Frame I Black Anodized Aluminium Alloy - Good aesthetics for residential applications ' J-Box IP 65 or IP 67 rated ® - 1-V CURVES OF PV MODULE(245W) I Cables r Photovoltaic Technology cable 4.0 mm'(0.006 inches'), ®�+3� i - } 1200 mm(47.2 inches) f to__m 1 Connector H4 Amphenol POW OUT PUT GUARANTEE 9m T000W/m' ER Fire type ' UL 1703 Type 2 for Solar Cif YP ! YP Y , Highly reliable due to stringent quality control + - 9 Y 9 4 Y , _6. • Over 30 in-house tests(UV,Ti HE and many more) e. m As a leading global manufacturer In-house testing goes well beyond certification requirements 4' eew/ - TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic PID resistant 3m u.. - " ` ' t! 20ow/m' Nominal0 Operating Cell r Operational Temperature -40-+85°C products,we believe close F ' z.W r i Temperature(NOCT) � 44°C(±2°C) 1 ' cooperation with our partners y I L Maximum System 600V DC(UL) 4 is critical to success. with local 9 f �- ( Temperature Coefficient of Pm r-0.41%/°C I Voltage I 0.00 to.- 20.°' 30.0° !, l . presence around the globe,Trina istage Vol Temperature Coefficient of Voc t -0.32%/°C Max Series Fuse Rating 115A f 1 able to provide exceptional service Temperature Coefficient of Isc 0.05%/°C t i P to each customer in each market Certified to withstand challenging environmental i -- -� ` and supplement our innovative, conditions , I reliable products with the backing + 9 wind I I 2400 Pa nd load ® I, of Trina as d strong,bankable i I WARRANTY • 5400 Pa snow load _. .- partner. s are committed r 10 year Product Workmanship Warranty I to buildingstrategic,mutually ' I 9 Y beneficial collaboration with � i l25 year Linear Power warranty ( Pleas refer to product warranty for details) installers;developers,distributors ' j 1 a sl •• , e and other partners as the 1 backbone of our shared success in - - 1 CERTIFICATION i driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY f PACKAGING CONFIGURATION " SP• �-- 10 Year ProductWarranty•25 Year Linear Power Warranty Lsrro °s f Madules.per bax:z6 pieces Trina Solar Limited - s; , f www.trinasolar.com - R Modules per 40'container 728 pieces - ,� Additional value fro l f EU-NE r.a„a 1 0 90% ,., mTrfna Salal,3 linear wgrfgn CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. poMV4TjB �4 m ' c ,.f I�N O'2014 Trina Solar Limited.All rights reserved.Specifications included in this dotasheet are subject to" Trun-asolar r,Bq% I ' �, m 4�o�n�solar - _ .change without notice. Smart Energy Together rears --- 5 - to Smartzo 2s Smart Energy Together r�'coMPPo° - ,--,_._-1n•IJ.Trina standard 0.hdr e n solar - oo � So I a r=oo SolarEdge Power Optimizer y' Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer Module Add-On For North America P30B P350 P400 (for 60-cell PV (for 72•cell PV (for 96-cell PV • "' modules) modules) modules) INPUT P300 / P350 / P400 Rated Input DC Powers I 300 350 400 W Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc ._... p ...g...g ... .. ..... ......... ......... ...... .... MPPTO eratin Ran e 8 48 8-60 8-80 Vdc .....I........... ....... .............. .......................... ... .. ...... .. ...... .... .. ` - Maximum Short Grcw[Current(Isc) 10 Adc Max mum DC Input Current 12.5 Adc _ Mawmum ETfi iegcy 99:5 .....%... .................................................................... ...... .. .. Weighted Efficiency 98.8 % ..Cat ......... ........: ......... .........' ......... ...... ........... 4 +" Overvoltage Category II ±OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) , ` l - _Maximum Output Curren[ 15 Adc - Maximum Output Voltage 60 Vdc .• 'pL v OUTPUT DURING STANDBY(POWER_OPTIM_I_ZER.DISCONNECTED FROM INVERTER OR INVERTER_OFF)- 1� Safety Output Voltage per Power Optimizer 1 - Vdc �eeeefff� Itt I STANDARD COMPLIANCE - fFCC Part..Class..IEC61000 6 2,I..... I 0 6 3 Safety IEC62109 1(class II safety),UL1741 .. .. ... .... .:. ..... ......... .... ........ .... .f'- ... RoFIS _ Yes - - (INSTALLATION SPECIFICATIONS , 410, ... • Maximum Allowed System Voltage 1000 Vdc ! ......... Allow .V olt.g........... .... _. .: .. .. Dimensions(W x L x N) 141 x 212 x 405/5.55 x 8.34 x159 mm/in We di ight(including cables) 950/2.1 .............I.. .......................... ......................... ..... .......... .._...... ........ ... ....... .:.. ..Br/�b... Output Wire Type/Connector ... ... ,.... Double Insulate d,Amphenol ..., ,.,,, _ ... ........ P „ .""` Output Wue Length 0.95/30 I 12/319• m/ft ................ ............................................... .. - Operating Temperature Range - 40 85/40 185 'C/•F " - Protection Rating IP65/NEMA4. ............... .. ............................ ... .... ....... .... ...... ......... ................. ..... ...-....... Relative Humidity 0-100 .... ......... . .. ....... ............. .. ......... .............. ... ..... _ ... Raved 4C powerofthe module.M dueal uP h,.5%power roleranceal—d (PV SYSTEM DESIGN USING A SOLAREDGE I "" THREE PHASE*' THREE PHASE ° - (e T M PINVERTER SINGLE PHASE ": ,.^;. 208V +' -.480V PV power optimization at the module-level nn�mumStnngLengtn(Poweropbmizers) g 10 18 Up to 25%more energy — - "Mawmum String Length(Power Optimizers),,,,,,,,,,,,,, .25 ... .25, .. 50. .. Mawmum Power per Str ng.. ........ 5250 ...... .. 6000.. ... ...........12750 W ... - .. Superiovefficiency(99.5%) - ....... g.. .. ..... ............... .. - - Parallel Strings of Different Lengths or Orientations Yes " — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading - ""'"" .."" " " '"''""''"'' ' •'"""•"'•"""" "--'— .. '' '-' - - - ••"'•"•"' _ - „ - - Flexible system design for maximum space utilization - ." — Fast installation with a single bolt ». - - - �: _a•".,,.I v f ..r�>.., +hE ';` ° ...s'Ea....•f«,..::; .'t.&.,.,�1,e: 'r- ,' a�,:.la. a�; . ,rr^ `-,'a c'i.°, ,. ,s# Next generation maintenance with module-level monitoring r ' - - — Module-level voltage shutdown for installer and firefighter safety �s USA - GERMANY ITALY - FRANCE ' JAPAN - CHINA - ISRAEL - AUSTRALIA www.5olaredge.us ya�p�auu"�S a f S� a r RXo .- Single Phase Inverters for North America OI _ O 0 Q �� SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ u� SE760OA-US/SE1000OA-US/SE1140OA-US n SE3000A-US SE380OA-US SESOOOA-US SE6000A-US SE760OA-US SE1000A-US SE1140OA-US . I`J���_" OUTPUT - ' SolarEdge single .Phase Inverters JpC Nominal AC Power Output 3000 3800 5000 6000 - 7600 - 100 0@2 OV 11400 VA r ............................. �. .; ,.�. - .- a. 5400 @ 208V 10800 @ 208V • • "" ' ' � n��� Max.AC Power Output 3300 4150 6000 8350 12000 VA For North America u• 545o@Zagv ....... ... .... .. .... 1D9so@2.... ................... ......... AC Output Voltage Min.Nom:Max.* SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ . 183 208 229 Vac•...... ........• AC Output Voltage Mm.Nom:Max.• ✓ ✓ ✓' ✓ 211-240-264 Vac ✓ - ✓ ✓ SE760OA-US/SE1000OA-US/SE1140OA-US .... ........... ... ............... ................ ... .. ...... ... ...: .... ................... ....... .. .... . . . .... ......... ... . .... .... . AC Frequency Min.Nom::Max.` 59.3 60 60.5(with HI country setting -60:60.5) Hz - .... .... .. ... ...24 @ 208V . ........... 48 @ 208V .... ......... ,. .-. '. - `: x• - - Max.Continuous Output Current 12 5 16 25 32 47.5 A 21@240V 42@240V -•-••-•- -••••.•-- , .. , ,. ..... ........ ........... ............. ................ ............... ................. ....... .... ................ .. .... ,.,. .. .. GFDI ..................... .A. Utility Mon _ _ Protection,Country g Monitoring,Islanding P ro n,Count Configurable - Yes - ��dverte} Thresholds f�* 25 oaf '.INPUT —'—` 12� � - Recommended Max.DC Power** lea _ - 3750 4750 6250 7500 9500 12400 14250 W W tranlY , ($51.............. .................:.. g a ............... ................. ...... ........ ... ......... .. ................ .............. Transformer less,Ungrounded Yes .............. ......... ....... ....... ......... ..:............................................ ..... ...... ................................................... . Max.Input ..... ....Voltage - 500 Vdc. . ...... ...... . ...... .................................................... .......................................................... ........... Nom.DC Input Voltage. ... .. .........325 @.208V/-350@240V......... ............•.-_.....--..:.---...--.. ..Vdc --�--�-----�� •16.5 208V 33 208V - - Max.Input Current 9.5 13 @ 18 23 @ 34.5 Adc ... ............L..............[A :-.@-240V. .. .... .... ... ... 30.5@.240V..I.................. 155 Max.Input Short Circuit Current 30 -I - 45 Adc- - ` - Reverse-Polarity Protection Yes ' ...... ....................... ......... ......... ............... ............. . ......... ........................................ ......... ..... ... - _ Ground Fault Isolation Detection 600ka Sensitivity r .................. ..... ... ............. ............... .. MaximumInverterEfficiency.......... 97.7--. --.98.2--- .. 983-„•- ...98.3... ....98. 98•,.- .....98... ..%, ...... ................. ..... ..... .. .97.5 @ 208V. 97 @ 208V ........... GEC Weighted Efficiency 97.S 98 97.5 97.5 97.5 _ 98 20V 97.5 @,240V.................... ........... Nighttime Power Consu mption <2.5 @ <4 W ADDITIONAL FEATURES ( :� - Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) - - _.r fit' Revenue Grade Data,ANSI C12.1.....I................................................... ...Optional. ..... . ... ......................................I........... f - - STANDARD COMPLIANCE - "• ' - - Safety UL1741,UL1699B,UL1998,CSA 22.2 Grid Connection Standards............. .. ..............._........ ...... ....IEEE1547.... ................................................. ....... -' ..... ............_.......... .. - Emissions _ FCC part1S class B _T INSTALLATION SPECIFICATIONS I AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG ............................... .................... .. . ... .... ................................ ..... ......... DC input conduit size/#of strings/ .. .... .. .. . ................................................ .. ... '+�.,..,„,..- � • � - 3/4"minimum/1 2 strings/24-6 AWG � 3/4"minimum/1 2 strings/14 6 AWG AWG range............. .... .. Dimensions with AC/DC Safety-••-••• - ••-•30.5x12.5x7•/.•••••• ..................................30.5x 12.5 x7.5 --• �••in/-• 775 x 315 x 172 775 x 315 x 191 x 10.5/J75 mm 305x125 x315x260 Weight with AC/DC Safety Switch 51.2/23 2 54.7/24.7 88.4/40 1 lb/kg - ........................................... .................................. ......................... ...... ........... .... .. ..... .... ..... .... . . Cooling. .Natural Convection - Fans(userreplaceable) .................. ................-.. ... .................................. .......... .............-...... ... ... ......... .............. ......... .. ......... ....... Noise The best choice for SolarEdge enabled systems t Mi:n.- ..., . .......T'e'm ..... ..-. <2s .................. ... --- -„...••. .•-••. ...<so•.. -,--- .... dBA- g Y Min Max Operating Temperature .................. 13 to+140/-25 to+60(CAN version 40 to+60) F/ C Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance Range SU...i................._...................-........ ....... ...................................... ..... Superior efficiency(98%) Protection Rating _ NE* 3R .•••• - . •For other regional settings please contact SolarEdge support. - Small,lightweight and easy to install on provided bracket Limited to125%for location,where the yearly average high tempeatureis above n•F/25•C and to135%for locations where ais below n•F/2s•C. • For detailed information,refer to htto//www solaredee us/files/odbl nyerter do ovens i ne-eu de odf Built-in module-level monitoring .•A higher current source maybe used;the inverter will limit is input current to the values stated. ( - ••CAN P/Ns are eligible for the Ontario FIT and microFiT(microFIT exc.SE11400A US-CAN) - Internet connection through Ethernet or Wireless Outdoor and indoor installation Yg — --•—^� t Fixed voltage inverter,DC/AC conversion only _. Pre-assembled AC/DC Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 sutsv�� •.����J"���� USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL WWW,SOlaredge.US . - - - - F-Mwa_ •• �•uuc:`+ uu aauw�mu�u � i. .. i i