Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0045 PARTRIDGE WAY
� . I 1 TOWN OF BARNSTABLE BUILDING PERMIT APPLICATION •21®S P r I O P DO -,Application* t# V I V , Map acepp Health Division Date Issuedy Conservation Division Application Fee. i;�p. Planning Dept `Permit Fee 7 2- 0 Date Definitive Plan Approved by Planning Board I / 0`Z7r�� . Historic - OKH Preservation/ Hyannis Project Street Address t'ac+rAe. wa y ' Village Cenkf—yi l/e, Owner S'G© �' SG�� � Address �� Paf _� It �ent2n/s�� �wg-2 Telephone $O� 7 ZJrs Permit Request A Irv, 0. 57, ! 14Z Sokr DAn ®Vo 144 01C U nale Flu, imo wn 4--e . r-i i—P. Square feet: 1 st floor: existing proposed 2nd.floor: existing proposed Total new Zoning District Flood Plain Groundwater Overlay 00 Project Valuati` 0 DD• Construction Type Lot Size Grandfathered: 0 Yes ❑ No If yes, attach supporting documentation. Dwelling Type: Single Family Q Two Family ❑ Multi-Family(# units) Age of Existing Structure Historic House: ❑Yes ❑ No On Old King's Highway: ❑Yes ❑ No Basement-&.Pe: ❑ dull ❑Crawl ❑Walkout ❑ Other r Baser Tent Finished Area (sq.ft.) Basement Unfinished Area (sq.ft) Number of Baths: Full':;existing new Half: existing new Number✓of Brooms:f existing _new Total R&m C,qunt (not ricluding baths): existing new First Floor Room Count Heat Type and Fuel: ❑ Gas ❑Oil ❑ Electric ❑ Other Central Air: ❑Yes ❑ No Fireplaces: Existing New Existing wood/coal stove: ❑Yes ❑ No Detached garage: ❑ existing ❑ new size—Pool: ❑ existing ❑ new size _ Barn: ❑existing ❑ new size_ Attached garage: ❑ existing ❑ new size _Shed: ❑ existing ❑ new size _ Other: Zoning Board of Appeals Authorization ❑ Appeal # Recorded ❑ Commercial ❑Yes ❑ No If yes, site plan review# Current Use Proposed Use APPLICANT INFORMATION (BUILDER OR HOMEOWNER) 7 Name Ja.�� ��� Telephone Number �� M Address / Z0 &&<p License # q0 213 aky'ayin"s MA (0260 f Home Improvement Contractor# 160,_?(V,"0 Worker's Compensation # W6f5 OgO /O/ � ALL CONSTRUCTION DEBRIS RESULTING FROM THIS PROJECT WILL BE TAKEN TO SIGNATURE DATE 5 70 h FOR OFFICIAL USE ONLY { APPLICATION# `'DATE ISSUED, _ MAP/PARCEL NO. ADDRESS VILLAGE C OWNER DATE OF INSPECTION: FOUNDATION': FRAME INSULATION. FIREPLACE ELECTRICAL: ROUGH FINAL .t PLUMBING: ROUGH FINAL GAS: ,,;«. . ROUGH FINAL FINAL BUILDING A `Qa ,, ." -DATE CLOSED OUT ASSOCIATION PLAN NO., } a ' s s�Ilc:;ilfiom I n 3p& 2O3.2 load and lbensmecm& wamm, byan providedwhh sem 7betg)lehebw 4fiamMuMa's B�a� art ae apt �iv+e � ' 2f4 Sb .ode �) tiou 2t4 uDhW Cw1L jjmpu%��fiwvadow mofgtttssh a0dtheIs sco=w�' saw ifs * WSW saw pasf�lsirdr $?.�'r 266 3 '- 269 F)ot #k @.46 S� - 235 - pm 1656x & 0.46 sm 235 _ 20 - Hemrw am §m 212 243 E wLFl (North) M6 235 2 � (E af2 psim� -. aFi ampi�.; €m 266 - 304 _qxm=LbTam Buffft rod-- Noompj tm ateem6eddedlaaaa w,@r swf _ a t� a FjydeAmmTm~CAama p � . `" ✓fie Z�Jamr��zaruaea`� a ✓fac�uoeCla Office of Consumer Affairs&B smess Regulation I 1 jrisc.or registration valid for individul use only HOME IMPROVEMENT CONTRACTOR before the expiration date. If found return Registration r�160360 Type: Offce of Consumer Affairs and Business Reat►on / Expiration,-,,7/r1.6/2012 DBA lOParlc Plaza-Suite 5170 Boston,MA 02116 E2 OLAR • - JASON STOOTS f 120 CHASE''ST l HYANNIS; MA 02601 Undersecretary No v lid without signature ! - !Nlassachusetts- Department of Public Safetc JASON STOOTS Board of Buildim-, Re�gul ftions :tnd Standards Construction Supervisor License / Restricted CS 90293 ,.; ... . ►S ® inc to: 00 Photovoltaic Installations y 120 Chase Street JASON D STOOTS •' 1 -'. K. (' Hy annis MA 02601 120 CHASE ST F i. CS License 090293 MA 3892237 cell:508 ce . . NABCEP# 938085 HYANNIS, MA 02601 NoNh Amariwn Board m - office/fax:508.775.1385 'Y 7- Jason@e2solarcapecod.com www.e2solarcapecod.com expiration: 4/28/2012 ('ununissiunu Tr#.''20887� ' The Commonwealth of Massachusetts Department of Industrial Accidents A Office oflnvestigations w i 600 Waslaingion Street Boston,Mass 02111 www.mass gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Dame(Business/Organizationlindttvidual): EZ `o tri.-r G Address: X2 0 Cyr•« �. City/State/Zip: r±u s,n s , M K G 2_(oO i Phone#: SC)9—`)7) S— t 3`&S Are you an employer?Check the appropriate box: Type of project(required): 1.)(�I am an employer with 7 4.G I am a general contractor and 1 6.L New construction employees(full and/or part time).* have hired the sub-contractors 7.0 Remodeling 2.= I am a sole proprietor or partner- listed on the attached sheet. ship and have no employees These sub-contractors have 8. D. Demolition working for me in any capacity. employees and have workers' [No workers'comp.insurance comp.insurance. 9.7 Building addition required] 5.0 We area corporation and its 10. D Electrical repairs or additions 3. Di I am a homeowner doing all work officers have exercised their myself [No workers'comp. right of exemption perm MGL 71.�Plumbing repairs or additions insurance required]t c.152,§1(4),and we have no 12.0 Roof repairs employees.[no workers' 13.X Other So 0.! C- . comp_insurance required.] (� *Any applicant that checks box KI must also fill out the section below showing their workers'compensation policy information. Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContactors that check this box must attach an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the subcontractors have employees,they must provide their workers comp.policy number. I am an employer that is providing workers'compensation utsurance for my employees.Below is the policy and job site information. t ; Insurance Company Name: 1 Jr t,;1;.., d l�� t .�i 1 5 v ►`ra .�r r Policy#or Self ins Lic_ ial C.C. G D9 G y .O 1 ZI✓i.i, Expiration Date: 03' Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration(date). Failure to secure coverage as required under Section 25a of MGL 152 can lead to the imposition of criminal penalties of a fine up to$1,500-00 and/or one year imprisonment as well as civil penalties in the form of a STOP WORK ORDER and a fine of $250.00 a day against violator_Be advised that a copy of this statement maybe forwarded to the Office of Investigations of the DIA for coverage verification. I do Herby cerfib7 under the pains and penalties ofperjury that the information provided above is true and correct. Si alure: &L— Date: Pratt Manie: fLn, _S`+C7l i Phone Ak 50R---i )S— Q1.5 Of use only Do not write in this area to be completed by city or town official City or Town• Permit/license#• Issuing Authority(circle one): I.Board of Heath 2.. Building Department 3.City/Totiva Clerk 4_Electrical Inspector 5.Plumbing Inspector. 6.Other Contact person: Phone#: _ Client#: 18348 2E2SO ACORD. . CERTIFICATE OF LIABILITY INSURANCE DATDDM 07/25/25/201, _ THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed.If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Dowling&O'Neil NAME: PHONE Insurance Agency A/C,N Eat:508 775-1620 ac,No: 5087781218 973 lyannough Rd., PO Box 1990 ADDRESS: Hyannis,MA 02601 INSURERS)AFFORDING COVERAGE NAIC# INSURER A:Acadia Insurance INSURED E2 Solar,Inc. INSURER B:Associated Employers Insurance Jason Stoots INSURER C: 120 Chase Street INSURER D: Hyannis,MA 02601 INSURER E INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PE RIOD ERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN SR ADDL UB LTR TYPE OF INSURANCE POLICY EFF POLICY EXP INSR WVD POLICY NUMBER MM/DD MM/DD LIMITS A GENERAL LIABILITY CPP033453211 4/22/2011 04/2212012 EACH OCCURRENCE $1,000,000 X COMMERCIAL GENERAL LIABILITY PR AGE TO RENTED EMISES Ea occurrence $250000 CLAIMS-MADE X OCCUR MED EXP(Any one person) $5 000 PERSONAL&ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER:POLICY PRO PRODUCTS-COMP/OP AGG $2,000,000 LOC JECT $ A AUTOMOBILE LIABILITY MAA033967111 4/22/2011 04/22/201 E°a�eoDtSINGLE LIMIT $1,000,000 ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS X AUTOS BODILY INJURY(Per accident) $ X HIRED AUTOS X AUTOS PROPERTY DAMAGE $ Per accident $ A X UMBRELLA LIAB OCCUR CUA033453411 4/22/2011 04/22/201 EACH OCCURRENCE $1 000 000 EXCESS LIAB HCLAIMS-MADE AGGREGATE $1,000,000 DED I X I RETENTION$0 $ B WORKERS COMPENSATION WCC5008041072011 3/16/2011 03/16/201 X wCSTATU- OTH- AND EMPLOYERS'LIABILITY Y/N LI ANY PROPRIETOR/PARTNERIEXECUTIVE❑ E.L.EACH ACCIDENT $500 000 OFFICER/MEMBER EXCLUDED. Y N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $500 000 It yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $500,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) Alison Alessi and Gregory Gorman are excluded from the workers compensation policy. Insurance coverage is limited to the terms,conditions,exclusions,other limitations and endorsements. Nothing contained in the certificate of insurance shall be deemed to have altered,waived,or extended the coverage provided by the policy provisions. CERTIFICATE HOLDER CANCELLATION Scott Schofield SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 45 Partridge Way ACCORDANCE WITH THE POLICY PROVISIONS. Centerville, MA 02632 AUTHORIZED REPRESENTATIVE . ©1988-2010 ACORD CORPORATION.All rights reserved. ACORD 25(2010/05) 1 of 1 The ACORD name and logo are registered marks of ACORD #S83912/M83906 LS1 . ar Photovoltaic:Installations E2 SOLAR INC 120 Chase Street Hyannis, MA 02601 (508) 237-3892 CS License#CS090293 Home Improvement Contractor's Lic. # 160360 e2SolarPV@gmail.com Contract for Photovoltaics OWNER'S NAME: Scott Schofield PROJECT ADDRESS: 45 Partridge Way Centerville, MA 02632 1. PARTIES: This contract (hereinafter referred to as "Contract") is made and entered into on this 15tn day of July, 2011 by and between Scott Schofield (hereinafter referred to as "Owner"); and E2 SOLAR INC. (hereinafter referred to as "E2Solar" or"Contractor"). WHEREAS, Owner seeks to have one (1) 5.405 DC KW grid tie solar photovoltaic (PV) system hereinafter called "the system" professionally designed and installed at the above-named project address. WHEREAS, Contractor agrees to install the systems in accordance with all local code requirements and in accordance with current National Electric Code. WHEREAS, Contractor agrees to install the systems in a professional and courteous manner, leaving the job site secure and clean at all times. THEREFORE, In consideration of the mutual promises contained herein, Contractor agrees to perform the following work: 2. GENERAL SCOPE OF WORK DESCRIPTION 2.1.) System Specifications: The 5,405 do Watt PV system will consist of twenty-three (23) Schott 235 Watt photovoltaic modules mounted to south facing roof area. The photovoltaic modules will be mounted to the roofs using Unirac mounting system. All roof penetrations will either meet or exceed the local building requirements. In addition the system will consist of twenty-three (23) UL listed Enphase M210 microinverters to be installed on each module. The AC disconnect will be located on the exterior the house, near the service entrance, with all appropriate signage posted as required by the utility. This system will connect to the electrical grid via the grid tie inverter. This system will not include a battery back up system meaning the system will not produce power in the event of a power outage. 8 ® e O ® a o s ® ® RAC Solar cunt Beam Canne flora Hardware SolarMoun L-Foot Part No.310065, 310€066,310067,31006131 • L-Foot material: One of the following extruded aluminum alloys:6005- T5,6105-T5,6061-T6 • Ultimate tensile:38ksi,Yield:35 ksi ° Finish:Clear or Dark Anodized ° L-Foot weight:varies based on height:-0.215 Ibs(98g) Allowable and design loads are valid when components are Bea ,., assembled with SolarMount series beams according to authorized Bolt UNIRAC documents ` L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593 3/8'-16 hex head screw and one errated �.;� ASTM F594 3/s°serrated flange nut Flange Nu •Use anti-seize and tighten to 30 ft-Ibs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory NOTE: Loads are given for the L-Foot to beam connection only;be X sure to check load limits for standoff,lag screw,or other �. attachment method 3_01 Applied Load Average Safety Design Resistance 3x SLOT FOR - Direction Ultimate Allowable Load Factor, Load Factor, K"AJDWAfE Ibs(N) Ibs(N) FS Ibs(N) 4) --' ' Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 2.01 Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664 e FLANGE NUT END CLAMP 0 OP MOUNTING FLANGE NUT CLAMP MID CLAMP T-BOLT 0 UGC-1 CLIP T-BOLT SOLAR MOUND RAIL T-BOLT UGC-1 CLIP f RAIL U1 000 00 U K RAC Installation Detail ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE SolarMount Rail ALBUQUERQUE, NM 87102 USA Top Mounting Clamp PHONE 505.242.6411 UNIRAC.COM Universal Grounding Clips_' URASSY-0006 �; S:\AutoCad Detail Library` ,-AD\URASSY-0006_Solar Mount Rail-UGC-1 Clip-Top Mount Clannp.dwq, 10/22/200uo 9:47:53 AM STANDARD RAIL L FOOT 3/8-16 X 3/4 HEX HEAD BOLT 3/8-16 FLANGE NUT O 48' 1 � 000 00OO u N IRA Installation Detail ©2008 UNIRAC, INC. 1411 BROADWAY BLVD NE SolarMount Rail ALBUQUERQUE, NM 87102 USA L-Foot Connection PHONE 505.242.6411 UNIRAC.COM URASSY-0002 Technical Data Electrical data Module type SCHOTT POLY'*'220 SCHOTT POLYT" 225 ` SCHOTT POLY'"'230 SCHOTT POLY-235- -- �:_ w Nominal power[Wpl pmaa u, �220�°"" �� >225 __ . .>230 -� >235 "' b Voltage at nominal power(VJ VmPP _29.7 29 8 30 0 _..�_ -. Current at nominal power[A]�.ImpP ._ 7.41�-. 7 55w Open-circuit voltage_[Vj V — _ r _ oc 36.5 36.7 w 36.9 Short i ' - _.. _ _ ..-c rwrt cunent[AJ _ _lsc�� 7 815-"" � .,.. �` `8.24�`" "` •833 �" � 37 1 8 42 o STC(1,000 W/rrt AM LS,cell temperature 25°C) o Power tolerance(as measured by Hasher):-0 Watts/+4.99 Watts = Power measurement accuracy:t 4% S Data at normal operating cell temperature (NOCT) Nominal power P IWPI PmPP 158 161 165" 169 Voltage of nominal power[Vl VmpP l 26.7 -"' -`` -26 9 -' ` 27.1 '_ _ Open circuit voltage(VJ a Vac 33.3 _ 33 7 3 9- �_ - - 33 5 Short circuit current[A] he 6 53 6'60 6 67 75` € e Temperature[°C] TNocr 47.2 ! 47. 6• _ . - _ _ NOCT(800 WIm,AM I.S,windspeed I m/s,ambient temperature 20°C) Power measurement accuracy:t 4% Data at Low Irradiation At a low irradiation intensity of 200 W/m-'(A14'1_3 and cell temperature 25°C)97%of the STC module efficiency(1000 W/m)will be achieved. Temperature coefficients 993/39.09' sons Power[orb/°C] 0 45 _ M COpen circuit voltage[4bI°Cj' "w' V` 0.33 Short-circuit current %° - ' o Characteristic data i o >n Solar cells_ per module 60 Cell type - 6`'(1 SG mm xY156 mm);full square" e Front panel i;p "-Low-iron solar glass,4'mm thick - Frame material Ariodiied aluminum "` $ Connection Junction box with 3 bypass diodes W PV WIRE,43.3"(1,100 mm)x 4 mm' i TYCO SolarLok connectors + Dimensions and weight Dimensions 66.34"(1,685 mm)x 39.09"(993 mm) tolerance+0.118"(3 mm) jThickness' 1.97"'(50 mm)tolerance t 0 04'(1 mm)' v E. _.. .- ., _ n Weight approx.50.61bs(23.0 kg) ' N I Limits System voltage[Vora f600 Maximum reverse curr`ent[A]* frame profile Operating module temperature[°C] - 40 to+85 Fire classification C 'No external current greater than Voc shall be applied to the module. T All dimensions in mm1'mches Qualifications The SCHOTT POLY'""220/225/230/235 Watt modules are certified to and meet the requirements of UL 1703. SA SCHOTT Solar reserves the rights to make specification changes without notice. For detailed product drawings and specifications,please contact SCHOTT Solar or an authorized reseller. SCHOTT Solar PV, Inc. U.S. Sales and Marketing U.S. Production Facility 6866 Santa Teresa Blvd. 5201 Hawking Drive, SE SCHOTT San lose, CA 95179 Albuquerque, NM 87106 Toll free: 888457-6527 Phone: 505-212-8500 Email-sales@us.schottsolar.com www.us.schoUsolar.com sdar r - SCHOTT Solar POLYTM s Polycrystalline Solar Modules At a glance ® Industry leading warranty, o Narrow output tolerance flL.fL"���IL.��L!iI1WIN3..Nl' I z. G Long-term reliability _ G High resistance to mechanical loads ®.Up-to-date features . j P - ® Environmentally friendly , Rely on SCHOTT Solar pV _ BuyAmerica with ton#idence- SCHOTT POLY-220/Z25/230/235 SCHOTT Solar has been a leading global developer and manufacturer of solar SCHOTT Solar POLYm PV modules are manufactured with.pride in products for over 52 years. Engineered in Germany and manufactured in America, Albuquerque, New Mexico from the high quality SCHOTT Solar PV modules are extremely durable and reliable as domestic and foreign components in demonstrated in several important ways: an ISO 9001:2008 certified facility. Industry leading warranty:SCHOTT Solar offers an industry leading linear power The modules from Albuquerque: output warranty for 25 years in addition to five years warranty for any defects in a Qualify as a domestic end product materials or workmanship.This enhancement provides 6%more guaranteed power under the Buy American Act(BAA) over the 25 year period compared to standard step-down warranties common in the p Qualify as a U.S.-made end product industry under the Trade Agreement Act(TAA) Narrow output tolerance:SCHOTT Solar POLYTM modules are among the industry o•Qualify as a domestic manufactured leaders in power output tolerances. SCHOTT Solar sorts all modules to a positive product under the American tolerance(minus zero watts)which provides for a stable, high energy output you Recovery St.Reinvestment.Act(ARRA) can feel secure in. Long-term reliability: SCHOTT modules are environmentally tested to double the industry certification standards for thermal cycling and damp heat tests to ensure consistent and superior performance over the long term. In addition, SCHOTT has performance data from over 25 years of actual field testing that supports our high quality products. High resistance to mechanical loads: SCHOTT Solar modules are tested to an extreme loading pressure of 5,400 Pa to,ensure additional security for your investment. Up-to-date features:SCHOTT Solar modules offer up-to-date electrical features such as double insulated PV cables for use with transformerless inverters and locking connectors. Environmentally friendly: Due to our concern with jobsite waste and disposal costs, w we bulk pack our modules in a manner that significantly reduces cardboard waste. SCHOTT solar o LL N N W z 0 0 Ld U > (23)PROPOSED SCHOTT 235 0 F- WATT PV MODULES, TOTAL: o Q 4ns KW0 0 Lo U a TITLE: 0 0 r<EXT'GX8 RAFTERS 16" PLANS & ELEVATIONS POSED SCHOTT 235 E WATT PV MODULES,TOTAL: 5.405 KW Wes_ 8 N- % �cn¢ o � M N ¢Z Dui U Z N r o N 6 O N 2 ROOF PLAN 3 EAST ELEVATION — /a°-�'-o• GENERAL NOTES: 1. PANELS ARE ATTACHED TO EXT'G 'm ROOF STRUCTURE WITH 16'X 5"SST l!!1 HEX LAGS,48"OC. TYP. WE 2. ALL RAIL AND MOUNTINGS ARE RATED FOR 125 MPH WIND LATERAL LOADS 3. EXISTING ROOF FRAMING CONSISTS OF 2X8 RAFTERS, 16"OC (23)PROPOSED SCHOTT 235 sheet: 08.17.2011 WATT PV MODULES, TOTAL: 5.405 KW PARTIAL SOUTH ELEVATION 1 THE EXPRESS WARRANTIES CONTAINED HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTABILITY, HABITABILITY, OR FITNESS FOR A PARTICULAR USE OR PURPOSE. THIS LIMITED WARRANTY EXCLUDES CONSEQUENTIAL AND INCIDENTAL DAMAGES AND LIMITS THE DURATION OF IMPLIED WARRANTIES TO THE FULLEST EXTENT PERMISSIBLE UNDER STATE AND FEDERAL LAW. 8.5 PERMITTING Contractor agrees to apply for and secure the necessary local building and electrical permits required to perform this work. All work performed will be done in compliance with the requirements of the local officials. 9. ENTIRE AGREEMENT, SEVERABILITY AND MODIFICATION This Agreement represents and contains the entire agreement between the parties. Prior discussions, verbal representations or written memoranda of any kind by Contractor or Owner that are not contained or referenced in this Contract are not a part of this Contract. In the event that any provision of this Contract is at any time held by a Court to be invalid or unenforceable, the parties agree that all other provisions of this Contract will remain in full force and effect. Any future modification of this Contract must be made in writing and executed by Owner and Contractor in order to be valid and binding upon the parties. The parties have read and understood, and agree to, all the terms and conditions contained in this Agreement. Date Jason Stoots for E2 Solar Inc, Contractor ate Scott Schofield Photovoltaic Contract Page 8 of 8 E2 Solar Inc.,Contractor Scott Schofield,Owner T? James A. Marx,Jr.P.E. Professional Engineer 10 High Mountain Road Ringwood,NJ 07456 E-mail:jamlight@bellatlantic.net January 10,2009 Unirac, Inc. 1411 Broadway Blvd.NE Albuquerque,NM 87102 °= To: Building Department or Others: RE: Engineer's Notice of Evaluation for UniRac SolarMountTM Cz Universal PV Module Mounting System for application to Massachusetts State ca Building Code 780 CMR 7'Ed. and One and Two Family Dwellings 7h'Ed. 00 M Dear Sir: I have evaluated the Unirac SolarMountTM"Code-Compliant Installation Manual 227", copyright February 2008 and certify that the information and results are accurate. To determine the design level forces,the appropriate wind speed and ground snow conditions must be determined as prescribed by local jurisdiction requirements and applied in accordance to the 7th Ed.of the Massachusetts State Building Code. The Massachusetts State Building Code for One and Two Family Dwelling requires that wind loading be determined based upon Table 5301.2(4)Basic Wind Speeds and Table 5301.2(2)Component and Cladding Loads for Building with a Mean Roof Height of 30 feet in Exposure B and Table 5301.2(3)Height and Exposure Adjustment Coefficients for Table 5301.2(2)of which replaces Unirac's Manual 227 Table 2 and Table 3 that follows ASCE 7-02/05 requirements..The Massachusetts State Building Code is dependent upon conditions of spatial form,height,exposure category and other structure parameters that are specified in the code provisions and illustrated in Figure 5301.2(8). For other building types not included by the Massachusetts State Building Code for One and Two Family Dwelling,the determination of basic wind speed should be determined by the 7th Ed.of the 780 CMR Massachusetts State Building Code that is referenced in Section 1604.10 and Table 1604.10 and replaces Unirac Manual 227 Figure 1. The determination of wind loading can be determined by Unirac's Manual 227 Table 2 or Table 3 using the aforesaid wind speed if the ASCE 7-05 Method 1 conditions are mef. James A. Marx,Jr.PE Page 2 of 3 The 7th Ed. of the 780 CMR Massachusetts State Building Code should be used to determine the snow loading on the solar panels that.is imposed on railing and roof mounting supports and conditions of balanced snow,unbalanced snow and drift loads that will need to be determined for either One and Two Family Dwelling or for other building types. For determining the Total Design Load,the Unirac Part.II procedure shall be replaced with 7th Ed.of the 780 CMR Massachusetts State Building Code, Section 1605.3 that has. Load Combinations Using the Allowable Stress Design(ASD)for which the determination of distributed load on the railing,w(plf)and the uplift point load shall be obtained for the selected use of railing in Unirac Manual 227 Table 8 and Table 9. The anchorage requirements for the installation are properly represented in the Unirac Manual 227 Table 12 that furnishes Lag Bolt pull-out loads(withdrawal capacities)in typical roof lumber(ASD). The Unirac design verification is based on: I. ASCE7-05—ASCE Standard II. "Steel Construction Manual," 13th Ed.,American Institute of Steel Construction, Chicago, IL,2005. III. "Aluminum Design Manual",The Aluminum Association,Washington D.C., 2005. IV. Mechanical Properties and Static Load Testing of Unirac extruded rails and related components obtained from Dr. Walter Gerstle,PE,Department of Civil Engineering,University of New Mexico,Albuquerque,NM Use: Unirac SolarMountTm is evaluated for use in locations where wind pressure requirements do not exceed 50 psf or snow load conditions do not exceed 45 psf ground snow loads. For loading in excess of either of the above stated conditions,Unirac,Inc. should be contacted for suitability of installation. f ;4 a r'. f c:: x_', -~ James A.MarI PE = Page 3 of 3 6 B Ms letter,I"certify that theT;hft& SolarMountTM assembly,when installed in accordance with the Installation Manual 227 and with the aforementioned a cation of PP the loading determination thatwill meet the.requirements7of the:building codes adopted i. by Massachusetts g z„ Others should evaluate the structure to which the Umrac SolarlVlountTM system is to:be ° connected'on a case by case basis,per Part I Instal' '.' ::Res- -"bilifies of the< Installation Manual,to ensure.its adequacy to accept attachments and to support all `X applied loadings per the building code a 3: � Please call;me if you have any questions or concerns ,,- A "' t I. Sincerely '1 G .",.-:-�'-.�1,'i�li:��w*_,,-T%f��_�,,..�!T�,;",:''-,.,.',-_:f��A.-�*"'._��-;""�:,_,�.,�gm,.�I._,..,,',-:�Q�._._'�.q...,o,,_'�.--�'J,,_'-.��:-::o','".,.:.i.,._I��-0;..�:.�.�'l,:':oW.'I:�T:".,_;,-_,'�,::,,-I�',_�T.`.�.�..,;,!:.4.-.Y�1-'�,.�.4�1__'".'.��"-��,I-,:��,�.:.���.'�1'=',;,..,.�--'-;;'.'o�,f�:[�'�''."��,�:-.,':'_.'.'z Z7."�.:,_'�,-T-W._:-".�v',".—�..-".�'-I�-::!_',,��"..j-;.I��."-.:'_�e.��'�---,.-Q a'._-,-_.-.0*_-,",:.1,�.,-,-�sa_"i�--.g O,,�--'-.'"_"��,.�-�v!""._,._�.,_-.,�'���'',�,--"_,�':j..,..n.L-�-_l-:L_'"�.�-;R"__,';_�,"�,-�"V-,,`_'AT-.._,_-!':"_-','"�_,'��--�i��_---�'.G'."�_.,�_M�'.._Q�e���",�'.',��,.�_".'t.'.�,_.�g'Q.''-'a��'.,..,�,.��6.�-�.�'_��1,_N--`.T:'�_..z ii��.ijl"a'.I,".',:..�Q"���.i.-��-:;7�-_,-;.',.��;�",''_-�"�1�.,'�-::'��,,x�%.I-?,"..-,'',�?��.'"";�q�,n-".K.;-.�:�.'.--..1...�l.—4"�'"o`-,."-'..�;�:;����.:�.'w.-.:.�"'���'0_.-.-�_��".---'.'.;o_�1-�,�'.;z,-;:'�:�.'K;...,�,...:..-�:'.T'_.'�,,a.''!�'��,,-:n.,�o.N.�-"_:.;�����:,:,.:'',.,":.�-'0.-'_�'��',,"_"-�,.-�s!."..,.�,-:X�.F',.�--:,.��:"�jWt..,n�,.�N,�;V-��....-';�,,.""'"..:�.'�4,0-�,:''�",�,-:.,,'.-:..��:.,'-',..�'w1,''..x�m'-.'�':.,..,,-�",Q'��.--�n;�',',�'5'.',�.,I,.�'..',�'-w-,�.R"...�5-:"��.��l�_..'�I�o_',,....;�v�-,�-:p��1.,-_",��"'.,�-,._',,",I.a.-_',''.�-�.,��'.,��w_-"-''':.�.'t.�'�y",'�.�....::.�-'-�'j��n"'".'',�.."0�.�'.yr--.w�'1",R-�;'�iI�',�.-��O0'"ay-�� 4r? Y' T) 4 ¢, James A Marx,J t ,, Professional Engineer - MA>License Nurr berr36365 Q . . . , 7 l Y .J ' {: �. 11 7 N'.k (.: -i P l . 1 f. \- { ✓ M _ i r r r A ) ?r f 1 fi - +f K s r g 5 { 1 r 1 C~ WA" , '' .l cc James Madnd,Unftc ,: r. Y x 1 6 ° t t R 3 J 2 " F t': S '; f i - i i ') 1 L T 5 L'. ${ r ir` ' t d .� -: is .�t3; F is w h ` fl r -: ...r- t x:� i .....: - �_ - - -.: t .. .. _ �. : .. _u. r.. t lSolarnc photovoltalc ',Installations enrer8y etWency renewable end 14 October 2011 E2 Solar Inc 120 Chase Street Hyannis MA Town of Barnstable _ Building Division 200 Main Street Hyannis MA 02601 Re:Solar Panels,45 Partridge Way,Centerville, MA To Whom It May Concern: As a registered architect,I have completed a structural review of the solar panel installation for the 2x8 roof for the Schofield residence,45 Partridge Way,Centerville MA. Based on the attached drawings, layout of the panels, rack connection clip spacing and the proposed lag screw connectors, we completed a wind loading analysis for uplift loads on the array to determine spacing of clips to rafters. The project is located in the 110 mph Exposure B wind zone and the uplift load for components and cladding was estimated at25"psf. Using the Unirac L-feet spaced 48" on center horizontally, and 36" on center along the rafter;the uplift is calculated to be approximately 240 Ibs/connector. By utilizing 5/16" x 5" lag screws to connect the L-feet into the 2x8 rafter, we calculate the.design withdrawal value, using the American Wood Council design criteria,to be approx. 500 Ibs,over double what is actually required. Sincerely, �%ED Afgcy� A.ALF�rFc� OU9711 9 9 o <n No.20259 Alison Alessi, Registered Architect HYANNIS Treasurer, E2 Solar �o� z�/h ��LTN 0F�PSgP TOVjq 0- ARU"STABLE =: - 31 7 ( _` i 1 ` !r f N c/) c/) w D m C m w O cn � X m 2Q O] rZ O � n � < rrl• _ OD — rrn. rn 0 � > 0 A m = n cmi) � � X O = x D Z � G� cn 0 . Z � � n G) iri mp0 � Zm Xn � 71 D:. p � r- r- " r m 0 -0 � � 0Cf) cn O � OC OD > O � � � � m r - O Z' I o - O Z Z hl cn Z N D - r ' 6+z O� �m m m PHOTOVOLTAIC INSTALLATION FOR: 120 CHASE STREET HVANNIs,MAozsol D SCHOFIELD RESIDENCE ' 508.237.3892 cell r ® r 508.775.1385fax 45 PARTRIDGE LANE e2solarpv@gmail.com CENTERVILLE MA www.e2solarcapecod.com 0 W IN 0 F 0 A IRINS TA B L Off OCT 2 7 AM 3 1 0 LL N (MO g oQo wpm U) mw o o LIJ � (23)PROPOSED SUNPOWER cUn F- It 230 WATTV MODULES, °P w w TOTAL: 5.29 KW o O a z a tU) TITLE: 0 0 EXT'G 2X8 RAFTERS 16". PLANS & oc Jim 'ELEVATIONS (23)PROPOSED SUNPOWER E 230 WATTPV MODULES, TOTAL: 5.29 KW. r a rQo `°o Q ujm m m .. - S L Z M n N �21 ROOF PLAN 3' EAST ELEVATION GENERAL NOTES: 1. PANELS ARE ATTACHED TO EXT'G Tm ROOF STRUCTURE WITH 16"X 5"SST VJL HEX LAGS,48"OC.TYP. ° 2. ALL RAIL AND MOUNTINGS ARE RATED FOR 125 MPH WIND LATERAL LOADS 3. EXISTING ROOF FRAMING CONSISTS OF 2X8 RAFTERS, 16"OC 230 PROPOSED SUNPOWERSafe: 0.23.20„ 230 WATT PV MODULES, she�: TOTAL: 5.29 KW i PARTIAL SOUTH ELEVATION A- 1 OWN OF BAIMNSTABIPLE, r S U N POWE R" E 18 / 230 SOLM PANEL EXCEPTIONAL EFFICIEAND PERFORMANCE BENEFITS E o Highest Efficiency SunPowerrm Solar Panels ar'e''the most S E R I E S efficient photovoltaic panels on the market today. More Power .Our panels produce more power in the same amount of space—up to 50% more than conventional designs and 100% more than thin film solar panels. Reduced`Installation Cost"-': More power per pane: means fewer panels per install. This saves both time - - . and money. y. .tl -11 Reliable and.Robust Design r Proven materials, tempered front glass, and a sturdy anodized frame allow The SunPowerT"'230 Solar Panel provides today's highest efficiency and panel to operate reliably in multiple performance. Utilizing72 all back-contact solar cells, the SunPower mounting configurations. y'° 230 delivers a total panel conversion efficiency of 18.5%. The panel's reduced voltage-temperature coefficient and exceptional low-light performance attributes provide outstanding energy delivery per peak power watt: SunPower's High Efficiency Advantage 18% 19% 20% r L ° 14% + 15/o 10% 10% 5% ° 0%. Thin Film �Conventi.onal �SunPower: SunPower k E 18 Series E 19 Series 4� SPR-230E-WHT D c us �§ OF /{( \ \ ƒ // A - , � �" ,,:- `_�.. POWE R" E • 230 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND PERFORMANCE ,y Electrical Data ( W Curve ( Measured at Standard Test Conditions(STCI:modionce of 1 000W/M2,AM 1 5 d cill temperature 25°C Peak Power(+5/3/) Pmax 230 W e 7,0 1000 W/m2 at 50 C Efficiency n 18 5 / 6,0 x 1000 W/m2 Rated Voltage Vmppµ 40.5 V ;�5,0 w " *. -- — --- --- Q N - - -- - F0 W/ma 40 i -.:. �. Rated Current Impp 5.68 A z ti- Open Circuit Voltage Voc 500 W/48.2 V '0 e P 9 ° mz O Short Circuit Current Isc — b 0S A v 2,0 F ¢ ;., 1,0 200 W/ma "s.•, - -> Maximum System Voltage UL 600 V 0,0 Temperature Coefficients Power(P) 0 38//.K i 0.. 10 20 30 ,} 40 50' 60 1 Voltage(Voc) `-132.5mV/K ' _ Voltage(V)` s ; Current(Isc) 3.5mA/K Current/voltage characteristics with dependence on irr6diance and module temperature. ..'£ --- '" NOCT 45 C+/-2 C °$ -- -- - r Series Fuse Rating 20 A Tested Operating Conditions Temperature 40 F to+185o F(40 C to+85'C) Mechanical Data 113_sf 550k /m2 5400 Pa front snow l Max load p 9 ( ) 9• . Solar Cells 72 SunPower all-back contact monocr stalline 50 psf 245kg/m2(2400 Pa)front and back-e.g.wind I x = Y Front Glass High transmission tempered glass Impact.Resistance•Hail l in (25 mm)at 52mph (23 m/s) - Junction Box �IP-65 rated with 3 bypass diodes e+ -- - - - — -- -- - - - Warranties and Certifications Dimensions:32 x 155 x 128(mm) # _ i Warranties 25 year hmited.power.warranty ' a� `Output Cables 1000mm length cables/MultiContact(MC4)connectors - — _ ` Frame . Anodized aluminum alloy type 6063 (black)- 10 year limited product warranty,,'; - - E ling $ a -- 9 ( 9) P03 Class C Ftre Ra.. .� Wel ht - 33 1 lbs. 15 0 k _ - — • Cerh Icahons Tested to UL 17 _._ Dimensions f }- -j Grounding Holes 2X b200 1 � s _ I _ t [.47.241 e . [ MM a 2X 200 `- 12 06,6 4X.180 QN) 7.85] 1.261 s 7:07] - 8X 04.2 4X 231 {2X 30 2X 577 [1.191 [22:70]'. [:171 a, [9.091 _ s 72X ��•_ 1.. E 9 6X 754 .42] • 2X 042. _ [29.69] 14 1559 '- 46 4X 322: =2X. 915' 2X 199 5 1 49 9 61.39J 81] ;[12.691 [7.851 - [ _ 4X 12 •2X 1535 [.47] ��� [60.45] s ---- CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Visit sunpowercorp.com for details .�:..` : SUNPOWER and the SUNPOWER logo are trademarks or registered trademarks of SunPower Corporation. sunpoWercorp.com ._ O February 2010 SunPower Corporation.All rights reserved.specifications included in this datasheet are subject to change without notice. ., . Document#001 G0680 Rev"/LTR_EN '"-•-��;. A}�}' FT 7 11• . 1 A: may,: 3.,�roq. . °FINE l Town of Barnstable Regulatory Services y s 9BMAMASS. Thomas F.Geiler,Director ArEo;9;.,A`e . Building Division Elbert Ulshoeffer,Building Commissioner r 367 Main Street, Hyannis,MA 02601 yr r , Office: 508-882 4038 Fax: 508-790-6230 y f , /Z_ 4.� SHED REGISTRATION 120 square feet or less } �3 VVI Location of shed(address) Village S D d Property owner's name Telephone number Size of Shed - ' Map/Parcel —T Signature "I r Date Hyannis Main Street Waterfront B'�storic District? Old King's Highway Historic District Commission jurisdiction? Iy Conservation Commission(signature.,equh;.d) PLEASE NOTE: IF YOU ARE WITHIN--THE JURISDICTION OF ANY OF THE ABOVE COMMISSIONS,THERE MAY BE A REVIEW PROCESS AND APPLICATION FEE. PLEASE SEE THE APPROPRIATE COMMISSION FOR DETAILS. a { Y THIS FORM MUST BE ACCOMPANIED BY A PLOT PLAN Q-forms-shedreg °t 4 F N A , pe , _ra16 y, 7- fff • � Z�� ZZ.G l.�1 / � \ � � i. i --------IS �G t RI, #YE Z � I ,A No. 19334 Q F � v UR ST9� CE eT/S .�'/E•O •�.L�T pG4�c/ ' 77A,%47- Cais'1,oL YS Gs//rf,� s/OE,C Avo A/o T .Cacq �r 4.1 rE•r� �yiry/.v B/2 /NST,eUiy,�-�C/r- B.4`5EO Ate(/ .eEG/STE,eEIj � • 7-Ar �T /it/�cs ApF�,C /C T -.. �N < f-- r I-,r, - - -t. . f.. .. A 1 f I \ r C:. _ z� 97 r 4�� r w14LIAM '. $4 Y E No. 19334 0 ; � "/STERN 4yo Sol / G'E•e T/.cy 77,U�i7- T�1�. �ui✓� �"/or✓ LGG 4 T/O,C/ C� j/�Z-=Z//�L t` t '�5.�/OLWiu yE.eEO.C/ COMGL YS �jry SET8.4 C,�G S C,q L!-- .. .�EQU/.2Fis-1E.c/rS O.� T.�1E To wit/aF /='�L.A Al i� ✓STD-�3�L= .4�vv /s A/C r- .LOC.4 404zvr��, , BA XT.E,2 E V/Y �av 141-f/ �E'EG/STE,2c p SUeYE /NST,eUi��it/T,s U,21/EY 7 h'� Y�-c' osTE.21�/,C.C�a �l-4SS. D.�,,S,E•TS Syo1,c%S/S.�-�v�.,n�yo7- B� .4OG.L " - _ n .h ri'L<:i"_3'iX.iC :Y' J _N:.:✓'+` .y,-' �t�s h^.9^ TfY. r '83r�.+q r..'^F ^°c�rnyr� .- .-T - ,y ,. y ofTNE� TOWN OF BARNSTABLE 32574 Permit No. ....... ...... BUILDING DEPARTMENT TOWN OFFICE BUILDING Cash ................ HYANNIS,MASS.02601 Bond ......X.......... CERTIFICATE OF USE AND OCCUPANCY Issued to SCOTT SCHOFIELD Address lot 7 45 Pattridge Way, Centerville USE GROUP FIRE GRADING OCCUPANCY LOAD THIS PERMIT WILL NOT BE VALID, AND THE BUILDING SHALL NOT BE OCCUPIED UNTIL SIGNED BY THE BUILDING INSPECTOR UPON SATISFACTORY COMPLIANCE WITH TOWN REQUIREMENTS AND IN ACCORDANCE WITH SECTION 119.0 OF THE MASSACHUSETTS STATE BUILDING CODE. November 15 19....$9......... rs .......................... ................... %/�........ Building Inspector ��Py�� T�•,. TOWN OF BARNSTABLE BUILDING DEPARTMENT 2 sAHa7TAU : TOWN OFFICE BUILDING rua i639 � HYANNIS, MASS. 02601 MEMO TO: Town Clerk FROM: Building Department 1 DATE: t An Occupancy Permit has been issued for the building authorized by 3�.r .. BuildingPermit #..............................»�:...».....�........ ».. »..... issuedto ...... ... ..... »..............»....................................................................».............»...»»»..» ».».». Please.. release the performance bond. t' 'T0WN'0F BARNSTABLE, MASSACHUSE"TS BUILDING PERM17 / ,I DATE 19 PERMIT NO. APPLICANT 4 /� ADDRESS (NO.) (STREET) (CONTR'S LICENSE) - PERMIT TO (_) ySTORY NUMBER OF DWELLING UNITS (TYP -F PROVEMENT) N0. (PROPOS D USE) _ AT (LOCATION) ZONING (NO.) (STREET) ISTRICT BETWEEN AND (CROSS STREET) (CROSS STREET) SUBDIVISION LOT LOT BLOCK SIZE ~ BUILDING IS TO BE FT. WIDE,BY FT. LONG BY FT, IN HEIGHT AND SHALL CONFORM IN CONSTRUCT)( TO TYPE USE GROUP BASEMENT WALLS OR FOUNDATION (TYPE) REMARKS: i AREA OR //////� PERMITVOLUME ESTIMATED COST $ e5�a, lJ r FEE. / UBI SQUA FEET) OWNER ADDRESS BUILDING DEPT. BY i ( THIS. PERMIT CONVEYS NO RIGHT TO OCCUPY ANY STREET, ALLEY OR SIDEWALK OR ANY PART THEREOF. EITHER TEMPORARILY C ® PERMANENTLY. ENCROACHMENTS ON PUBLIC PROPERTY, NO,T SPECIFICALLY PERMITTED UNDER THE BUILDING CODE, MUST BE A PROVED BY THE JURISDICTION. STREET OR ALLEY GRADES AS WELL AS DEPTH AND LOCATION C FROM THE DEPART CATION OF PUBLIC SEW DEPARTMENT ER E OF PUBLIC W S MAY BE OBTA WORKS. T INE HE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM THE CONDIT IO' 'OF ANY APPLICABLE SUBDIVISION RESTRICTIONS. - MINIMUM OF THREE CALL APPROVED PLANS MUST I E RETAINED ON JOB AND THIS WHERE APPLICABLE SEPARATE INSPECTIONS REQUIRED FOR "- ALL CONSTRUCTION WORK: CARD KEPT POSTED UNTIL FINAL INSPECTION HAS BEEN PERMITS ARE REQUIRED FOR ` - ELECTRICAL, PLUMBING AND I. FOUNDATIONS OR FOOTINGS. MADE. WHERE A CERTIFICATE OF OCCUPANCY IS RE- MECHANICAL INSTALLATIONS. 2. PRIOR TO COVERING STRUCTURAL QUIRED,SUCH BUILDING SHALL NOT BE OCCUPIED UNTIL MEMBERS(READY TO LATH). 3. FINAL INSPECTION BEFORE FINAL INSPECTION HAS BEEN MADE. OCCUPANCY, POST THIS CARD SO IT IS VISIBLE FROM STREET BUILDING INSPECTION APPROVALS i PLUMBING INSPECTION PROVALS ELECTRICAL INSPECTION APPROVALS 2 ,r�I 2 3 HEATING INSP TION APPROVALS ENGINEERING DEPARTMENT• t ClJL 6e+ SJi3 Z'T VZI lt)6�!/tiVC. OTHER BOARD OF HEALTH WORK SHALL NOT PROCEED UNTIL THE INSPEC- PERMIT WILL BECOME NULL AND VOID IF CONSTRUCTION e TOR HAS APPROVED THE VARIODUS STAGES OF I WORK IS NOT STARTED WITHIN SIX MONTHS OF DATE THE INSPECTIONS INDICATED ON THIS CARD CAN CONSTRUCTION. PERMIT IS ISSUED AS NOTED ABOVE. ARRANGED FOR BY TELEPHONE OR WRITT:. NOTIFICATION. ' X o(,,o Sl f3A3tT� } c TER \ LLlif AN�s 29733 ' a \d 'So 10 -ice � ^ 50 All LA Z SG�ILE ►�►:gip' AP,PUCAA1t SL TT JG.t{OF1 E1. 7 UL �Et�tsTF etr MD .6u zgcice5 , CY1 LLF, Nt ass THE FOLLOWING IS/ARE THE BEST . IMAGES FROM POOR QUALITY ORIGINALS) I m DATA / / 83 f" L AST NI. U S E D Iry l 5 !-1 a,p Z 00 SUB NO. AVZS NO_ A/C HSE � REMARKS .. Al - 4/7 3 1 VIC r: � v ( c 2� Tz!cl�T IIrP r q ' r .``µ s t r ./r �' i y ijf. Y ia?�rt' '.�. ,-2Sd• v- °. �;4k-r ' �""'� 'pT. � t C• J'"t- �,�•� ��r � ?ar +St,t+p�i, r ..a'S..l�'T y�` ``'.ram ,,�t�4 p �`Q� 7, r _ `r �'•Y � � 4. t r t >< s T r 4Yr` �t}'2y� -�.t�x s� �, f >� . s� }�. •tom �,{`"� e r f 4- ��r !„v?� V "' kE v+.+r Y ,z,y 'kr rz"^ 4�+ � � ri� _"� �' i �-.'me tµ �"� ° s°:���--�G° s Y F 1�.t � �� wy -r•'' �� �: sT•y I� .a y a•r cy, 4-. i i.t.., t 1, v. < > � , P u4 1a- Y &. ..v,F• ',,yy t .rest it t :. z :c;, 3 F r i r' ` t o .5� Fr 3rer x 3 2 o f{T „��sM, 'y"vt.t.• t :r h. +yy,�} x11d4'.j-ty m # ,'3-+ , �nT .� •,, �r• r-37y"� y ,,js•;[_) � � y+�'rt.e x,�r�Zq'v ta� ."i�`i'T^�+¢}. t r .al_ � � 1 a ; A 'L 5 '.}! �+/ !,-L I \ � VNL { ti.� �?S Mi �� �� •,yyc S-�3e. ' .t✓ �. 17. �.�-�^L''�'t"�'.t�A �..` �."' �„�.�y,a�-� �r sr4ti��"�'� 7�s' „� .,.,�`c. ,tG�rs ib S Y � a � �ar.r��,c�,f� 1"0!•-�' �,.ss�s.-rny,/�^,,•.�-5�" .,y"3 ag`^ tom. ��„ i • 'srs�s +t. :_' yY, ft ,�; `fit r�"'� ®f3'r .•x r:�g�`.M •r. � x '.4 X S �,Y�.�LA. `�_-- 4'T c ,4•i �, fi'?ri t •�Lr a� y, '�` '' 'i 4�� '�f`Aisl WWI.r4:"h' - �Ffr - XM i � �. t `!. i�Y ii� -1•.��St� i,ttiC �' ,� — ax.fz-:.=.a"�� s �t y�'?���` +�s'�F� s =�� �1�+4>.>�•.��. W '.�-'�a� ,�;r��'�• rt a � r`r - � ..� t�£:A��*xr'rs'�`'I(�f'��3*.�„* L�� y �•s .r 6.�) _�� : .n � �:�s I I ICU r� A _ let �$a°aiygh�,F�P .Jc`a " - i �k':j.t �''+'• 4� 't; sz-� -a e a .s--i -- - ....,�%4..',••"��..-,�'_._ '�.. '� =�s-'�e'"- �c 3s�`�.4��'�� �`�h?..�:�,�3...c .. :utFPI'r...S�.e�t ��s4 mu ' ,I Assessor's office (1st floor): #4 �( /,// ss E A&sessor's map-and lot number . C �'e "�'�i. 'XBoard of Health (3rd floor): ...... Sewage Permit number .... .�.��/..1.. ? ���„:c �iR" r Z eaaa9?enLE, S Engineering Department (3rd ,floor): �S.�.. ................:... TOWN REGULATION,; moo 2639 ........ � House number ........................ ... . . '0>Fp a fit. gar Definitive PlanApproved by Planning �odrd ________________________________19-------- . APPLICATIONS PROCESSED 8:30-9:30 A.M. and 1:00•2:00 P.M. only TOWN. OF " BARNSTABLE. A ,, , BUILDING INSPECTOR APPLICATION FOR PERMIT TO .................................................. :. 5.1.n. TYPE.OF CONSTRUCTION:. .....;....t.cJ.LYL/.(/\'\+\!' .1.:..........YV� '...C: .......`1G.C! L.2:! ..................... :.................... lU.....- F . -......19... .: . 4 .TO THE INSPECTOR OF BUILDINGS: The undersigned hereby, applies for a permit according to the following,information: Location .....+s;1-6 ..��... ... �..................... ..... ... , . . ProposedUse ..... ...............................:..................................................... Zoning District .......... .. ........................................:..........Fire District .......� ..--.C}........4A..ti1 Name of Owner ......:. ..C.Q...tr.�Lktr ..-C..14J..........Address ... 3... ....J.0�4,.Z.44y ........ ...(;.y/.....C Name of Builder ....................................................................Address .................. Name 'of Architect .... ..../.7...........................................Address Number of ,Rooms..............6.................................................Foundation .../ O..f1✓...�.�.....CtO.el... d!-.ete.................. Exley for ....YV..D.(t :..s�.t3�.y.f�5.. -.: .l.f lalo.4a.✓.....Roofing ....✓ ..s Iv.12.a.. .....S.�Fr..�?.��/..25....................... Floors ....... ..G4d..�fJ. ..'.........................................................Interior ...... ............... �� .!!L�i./J....... .................`................ Heating .... 0. Gate. ..� 2S.:..............:.................Plumbing ........ ........��i.�.�......................................... Fireplace ....... � ' S fid.Ll2...................:...................Approximate Cost . .... t ©U.v.................................: . Area .......................................... Diagram of Lot and Building with.Dimensions Fee / ............... `:..................... WO I 20AA0` . g OCCUPANCY PERMITS REQUIRED FOR NEW DWELLINGS I hereby agree to conform to all the Rules and Regulations of the.Town of Barnstable regarding the .above construction. x Name .<.Z...%L ..... .. ..... ... ..... ................ Construction Supervisor's License ... SCHOFIELD, SCOTT t� 4 x `No 32574 Permit for .....1 z Stor s ....... �'.......... Sin le Famil Dwellin y ......g.....................y.................ing.......... Location ...Lot„7 Y.&.....1,/2 0 8 45 Partridge.,Way s .......... ... Centerville I 1` ; F • . Owner ...S,cott...S.ghofie.ld....................... } ' Type of Construction .•Frame - .......... 'h ........... ........................4...... a • • ` w *rot t et. , x Permit Granted January 19, 1`9 89 a Date of Inspection ... l Date ^Complete/d /..... . °.. `................:.......19�� A � , t 1 J j